Double Stack
Transcription
Double Stack
Advanced Heating & Hot Water Systems A TRUE 10 : 1 Turndown Ratio BTU Modulation Rates 100,000 -1,000,000 170,000 -1,700,005 Built in Redundancy (No Downtime) Small Footprint Prepiped Reverse Return ASME Stainless Steel Heat Exchanger Gas Fired Commercial Boiler Also Available: Volume Water Heater An Intelligent Design that Delivers Highly Efficient Hydronic Heating with 94.1% Thermal Efficiency SCAQMD Rule 1146.2 Heat Exchanger Bears the ASME “H” Stamp Double Stack MOD CON DOUBLE STACK • A Look Inside Stainless Steel Heat Exchanger Pressure Relief Valve Control Inlet Nipple Low Water Sensor Outlet Nipple Drain Valve Gas Valve Temperature & Pressure Gauge Eco High Limit Condensate Collection System Combustion Blower Gas Line Adjustable Leveling Feet MOD CON D S • Additional Features • Superior Condensate Collection System (Patent Pending) Easy to Service With Overflow Protection • PVC – CPVC – Stainless Steel Venting • Vents Up to 150 feet, Combined • Adjustable Legs • Direct Vent Sealed Combustion • Models Available in Natural or LP Gas • Easy Access to Wiring and Field Service of Combustion Heat Exchanger • Low Water Cutoff Standard Equipment • High Limit Manual Reset • Removable Front Cover Allows Easy Access to Burner Assembly • Zero Clearance to All Combustible Surfaces • Factory Installed AGA/ASME Rated Relief Valve • PC Monitoring for History – System Operation (Optional) • Self Diagnostic Electronic Control with Digital Readout to Monitor System Parameters MOD CON D S • Optional Equipment • System Sensor (Part # 7250P-324) • Indirect Sensor (Part # 7250P-325) • 6” Stainless Steel Outside Termination Vent Kit (V3000) • High and Low Gas Pressure Switch Kit with Manual Reset (Part # 7350P-600) • U.L. 353 Compliant Low Water Cut-Off Interface Kit with Manual Reset (Part # 7350P-601) • Alarm System (Part # 7350P-602) (to monitor any failure) • PC Interface Cable (Part # 7250P-320) • Boiler Caster Kit (Part # 7350P-604) • Mod Con Condensate Neutralizer (Part # 7350P-611) • Flow Switch Kit (Part #7450P-216) MOD CON DOUBLE STACK • Features Integrated Control System • Built-In Sequencer for up to 4 Mod Con Double Stacked Boilers -Top & Bottom Boilers are Sequenced • Digital Display with Led Status Indicators • Integrated Control Allows Only the Amount of Heated Energy Required • Control Feature Inputs for Outdoor Sensor, 0-10 VDC for Building Management System and Indirect Sensor • Built-in Low Water Cut Off with Additional Manual Reset High Limit Switch • Multiple Pump Outputs – Boiler Pump – System Pump – Indirect Pump • 24 Volt Monitor for System Safety • Dual Flame Sensing (Flame Probe & Spark Ignition Probe) Combustion System • Modulating Burner with a True 10 to 1 Turndown • Whisper Quiet Operation • Low NOx Operation • High Grade Inconel Burner • Reliable Spark Ignition Mod Con 1700 • Combined Vent System • Gas Valve (Tested to UL, FM, CSA Standards) Heat Exchanger • All Stainless Steel Construction • No Gaskets, Welded Construction, ASME Approved • 150 PSI Relief Rated Single Point Connection: Piping and Venting Prepiped Reverse Return • Easy to Service Highly Efficient Condensing Technology, means lower energy cost to you! 99 Quick Disconnect Design Double Heat Exchanger Design Offers Built-in Fail Safe (No Downtime) 97 95 Primary/Secondary or Primary Direct Piping 93 91 89 87 40 60 100 140 160 Return Water Temperature (°F ) HTP @ 20% HTP @ 60% HTP @ 100% Up to 94.1% Thermal Efficiency Space Savings High Efficiency Master / Follower Control System Dimensions & Specifications Model Mod Con 1000 Mod Con 1700 B A C D E F G H J K L M N F U E L S AV I N G S : O 72.5” 20.5” 36” 13.75” 8.375” 46” 6” 13.625” 14.5” 33.25” 43.75” 66.75” 63.25” 43.375” 72.5” 20.5” 36” 13.75” 8.375” 64.5” 8.25” 20” 18.75” 43.5” 62.375” 88.50” 63.25” 59” (based on running hours, calculated using FTC-published average energy costs, Jan. 2009; $1.21 per therm) The cost of fuel in some areas of the country has increased by almost 40% in just one year. The highly efficient modulating output of the Mod Con D S will provide a maximum payback on fuel savings. As the charts below illustrate, savings can result in a payback period in less than three years when compared to the conventional technology of other boilers. The Mod Con could save you as much as 50% on your present fuel bills. M O D C O N 1 70 0 1 Year Fuel Savings $11,998 $12,000 $ 9,000 $10,000 $2,000 O Cost of Operation 0 85% $ 5,998 $ 6,42 8 $4,000 80% $ 4,2 86 O N $ 4,16 0 N $ 5,5 4 6 $6,000 A $2 ,774 A $ 8,14 6 $8,000 1000 75% 1500 Yearly Hours of Operation 2000 M O D C O N 1700 3 Year Fuel Savings $40,000 D E F E F G H J K G H J K $35,000 $ 35,994 D $30,000 Please note: all dimensions are approximate and heights do not include adjustable legs. $5,000 L M L Cost of Operation 0 M 1000 $27,000 $ 24,438 85% $17, 9 97 $10,000 $19,284 $15,000 $12,858 Combined Vent System $20,000 $ 16,638 C $25,000 $12,480 C B $8,322 B 1500 80% 75% 2000 Yearly Hours of Operation M O D C O N 1 000 1 Year Fuel Savings $8,000 Inside the MOD CON $ 7,058 $7,000 $6,000 0 1000 85% 80% $3,026 $3,780 $2,270 $2,522 $1,000 Cost of Operation $1,632 $2,000 $ 3,528 $3,000 $5,042 $ 5,294 $5,000 $4,000 1500 75% 2000 Yearly Hours of Operation MOD CON 1000 3 Year Fuel Savings $25,000 Cost of Operation 0 1000 $15,126 1500 85% 80% $9,078 $11,340 $6,810 $7,566 $5,000 $4,896 $10,000 $ 10,584 $15,000 $ 15,882 $ 21,174 $20,000 75% 2000 Yearly Hours of Operation Model BTU / hr Input Low Fire Gross Output BTU / hr Net I=B=R BTU / hr Thermal Efficiency Boiler Water Volume Supply/ Return Conn. Mod Con 1000 100,000-1,000,000 940,000 818,000 94.1% 8.4 Gal. 3" 2" 6" 1010 7200 1250 3000 Mod Con 1700 170,000-1,700,005 1,600,000 1,390,000 94.1% 11.6 Gal. 3" 2.5" 8" 1160 6800 2200 3000 Gas Vent Conn. Dia. Est. Ship Wt. 120 Braley Road, East Freetown, MA 02717 • www.htproducts.com High Low Fan Fan Fan Speed at Speed Speed Ignition MKTLIT-42 - 09 / 2016 © HTP
Similar documents
Double Stack
• Adjustable Legs • Direct Vent Sealed Combustion • Models Available in Natural or LP Gas • Easy Access to Wiring and Field Service of Combustion Heat Exchanger
More informationMod Con™ VWH Hot Water Supply Boiler
• All Stainless Steel Construction • No Gaskets, Welded Construction. ASME Approved • 150 PSI Relief Rated • Easy to Service
More information