Selection Technical Information Finishes
Transcription
Selection Technical Information Finishes
Louvers Miami-Dade Wind-Driven Rain Drainable Non-Drainable Combination Operable Acoustical Formed Metal Penthouses Sight Screens Selection Technical Information Finishes pottorff.com Selection Guide W Dallas Victory Hotel, Dallas, TX Busch Stadium St. Louis, MO Disney Concert Hall Parking Facility Los Angeles, CA On Front Cover Fidelity Investments, Westlake TX Venetian Hotel, Las Vegas, NV Mesa Arts Center, Phoenix, AZ 1 Model Blade Depth Miami-Dade Louvers 5" ECD-545-MD 6" EFD-637-MD Wind-Driven Rain Louvers 4" ECV-445 5" ECD-545 6" ECD-635 5" ECV-545 6" ECV-645 7" ECD-745 7" EFJ-745 Drainable Louvers 2" EFD-245 4" EFD-435 4" EFD-437 4" EFD-445 6" EFD-637 6" EFD-645 6" ERD-645 Drainable-Head Louvers 4" EFJ-437-HP 6" EFJ-637-HP Non-Drainable Louvers 2" EFJ-245 2" EFY-245 4" EFJ-430 4" EFK-430 4" EFJ-437 4" EFK-437 4" EFJ-445 4" EFK-445 4" EFY-445 6" EFK-637 6" EFJ-645 Formed Metal Louvers 2" SFJ-245 4" SFJ-430 4" SFD-445 4" SFJ-445 4" SFK-445 4" SFV-445 6" SFJ-630 6" SFD-635 6" SFJ-645 6" SFK-645 Combination Louvers EBE-445 4" EBI-445 4" 4" EXD-437 6" EXD-645 Operable Louvers 4" EOJ-445 4" EOD-445 6" EOJ-637 6" EOD-637 Acoustical Louvers 6" EAA-645 8" EAA-845 SAJ-835 8" 12" SAJ-1235 12" EAA-1245 12" FAA-1245 Penthouse EFD-637-MDPH 6" EPJ-445 4" Sight Screens HJ-445 4" HJ-645 6" HT-401 4" HZ-200 2-1/4" VT-250 2" VT-654 4" VV-400 4" VV-500 5" Blade Angle Blade Style 45° 37-1/2° Horizontal Horizontal 45° 35° 37-1/2° 45° 37-1/2° 45° 45° Thinline-Drainable Drainable Drainable Drainable Drainable Drainable Recessed-Drainable 45° 45° 35° 45° 45° 45° 45° 37-1/2° 37-1/2° 45° 45° 30° 30° 37-1/2° 37-1/2° 45° 45° 45° 37-1/2° 45° 45° 30° 45° 45° 45° 45° 30° 35° 45° 45° 45° 45° 37-1/2° 37-1/2°– 45° 45° 45° 37-1/2° 37-1/2° 45° 45° 35° 35° 45° 45° 37-1/2° 45° — — — — — — — — Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal High Performance-J High Performance-J Thinline-J Thinline-Inverted Y J K J K J K Inverted Y K J J J Drainable J K Chevron J Drainable J K J-BD-Exhaust J-BD-Intake Combination Combination Operable-J Operable-Drainable Operable-J Operable-Drainable Extruded-Airfoil Extruded Airfoil Formed-J Formed-J Extruded-Airfoil Formed-Airfoil Extruded Aluminum Extruded Aluminum Horizontal-Inverted J Horizontal-Inverted J Horizontal Airfoil Horizontal-Cladding Vertical-Cladding Vertical-Cladding Vertical-V Vertical-V Free Area 46% 59% 36% 46% 54% 42% 46% 53% 50% 43% 58% 58% 47% 59% 55% 51% 56% 56% 47% 38% 57% 57% 57% 57% 50% 50% 39% 50% 50% 42% 51% 53% 48% 48% 38% 65% 62% 50% 50% Water Penetration Ratings Velocity (fpm) Air Volume (cfm) Page 1250 1250 1217 1250 1250 1197 1250 7125 9250 10508 8375 9250 10018 10000 3 3 3 3 3 3 3 912 915 8220 8226 1250 990 955 966 903 990 990 1050 990 583 383 889 889 721 721 689 689 745 832 800 603 847 715 775 775 600 825 815 800 800 49% 49% 45% 44% 689 689 1161 1050 30% 33% 33% 31% 26% 26% 980 870 808 924 999 999 49% 43% 56% 58% 59% 51% 50% 50% 60% 19% 24% 21% 39% 54% 683 1024 810 990 990 689 — — — — — — — — 9250 9405 2 2 6494 8984 8398 7425 9405 9240 8059 4 4 4 4 4 4 4 4373 2336 8090 8090 6547 6547 5549 5549 4589 6673 6416 4040 6945 6092 5991 5991 3648 8580 8044 6400 6400 5396 5396 8359 7455 5396 7096 7282 9108 4704 4611 4293 4528 4196 4196 9405 5549 — — — — — — — — 5 5 5 5 5 5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 6 6 7 7 7 7 7 7 7 7 8 8 8 8 8 8 9 9 10 10 10 10 10 10 10 10 Miami-Dade Louvers The EFD-637-MD and ECD-545-MD are engineered and tested to withstand extreme loads, debris impact, and cyclic fatigue failure associated with the severe weather effects of hurricanes (ECD-545-MD has Miami-Dade approval # 110429.04 and the EFD-637-MD has Miami-Dade approval # 11-0429.03). Constructed from 6063-T5 extruded aluminum, both models have single section assemblies up to 48” wide by 144” high. Specially designed water-resistant seam covers further enhance performance and aesthetics of these industry leading products. Single-section louvers are now available with the option of a factory-installed sleeve which allows louver installation without any mechanical anchoring to the building condition. ‹ ECD-545-MD (Sight Proof) Certified Ratings: 5" › Certified Ratings: All-Lite certifies that model ECD-545-MD shown hereon is licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance, water penetration and wind-driven rain ratings. Maximum Size Single Section - 48"w x 144"h Multiple Section - Unlimited width x 144"h Multiple Section - 48"w x Unlimited Height Wall Construction ECD-545-MD EFD-637-MD 5" 6" Blade Angle 45° Steel Direct Connection - Clip angles* Masonry Tension or Shear Connection - Clip angles* Wood Direct Connection - Clip angles* All Types (Single Section Only) Flanged sleeve with continuous retaining angles (No anchors required) All Types 37.5° *Anchors supplied by others Blade Style (6063-T5 Ext. Alum.) (%) (Sq. Ft.) Horizontal 0.081" 59 9.5 Horizontal › Installation Method Installations of unlimited width and height available with additional engineer-approved support structure. Depth 6" All-Lite certifies that model EFD-637-MD shown hereon is licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. Structural steel mullion support required for installations more than one section wide. Model ‹ EFD-637-MD Material 0.081" Free Area 46 7.4 Beginning Point of Water Penetration Ratings (cfm) Pressure Drop (In. Wg.) 9405 0.11 Velocity Airflow 1250 9250 (fpm) 990 0.22 Class A (29 mph) - Miami Dade Approval #11-0429.04 #11-0429.03 AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48"x 48" louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. AMCA Wind Driven Rain Ratings based upon a test louver size having 39-3/8” x 39-3/8” core area. 2 Wind-Driven Rain Louvers Backed by AMCA certification our wind-driven rain louvers offer exceptional protection under the most severe conditions and are available in frame depths from 4" to 7". The closely spaced vertical blade design of the ECV-645 provides our most effective wind-driven rain performance with 100% effectiveness at wind velocities up to 50 mph and rainfall up to 8 in/hr. When aesthetic requirements demand a more conventional horizontal blade profile our EFJ-745 is the ideal solution with 5" on center traditional J-blade fascia and 100% effectiveness @ 3 in/hr rain fall. Pottorff architectural products are designed for use in most geographical areas within the United States. Pottorff can also design modify or reinforce standard products for special requirements, such as high wind, heavy snow, industrial environments, special mounting conditions, etc. Consult your local representative for more information. ECV-645 ECV-545 ECV-445 ECD-545 ECD-635 EFJ-745 ECD-745 › plan view ‹ 4" ECV-445 › plan view 5" 6" ‹ ECV-645 ECV-545 Blade Style Model Depth ECD-545 5" Horizontal 5" Vertical ECV-445 ECD-635 ECV-545 ECV-645 ECD-745 EFJ-745 4" 6" 6" 7" 7" Vertical Horizontal Vertical Horizontal Horizontal Certified Ratings: ‹ (%) (Sq. Ft.) Wind Velocity Rainfall 46 7.4 7" › ‹ (In/Hr) Effectiveness Ratio (%) Class 29/50 mph 3/8 7196/7276 100.0/97.9 A/B 42 6.7 29/50 mph 3/8 7356/9485 99.9/99.6 A 53 8.4 29 mph 3 7244 99.9 36 5.7 54 8.6 46 7.4 50 8.0 29 mph 29 mph 50 mph 29 mph Pottorff certifies that model ECV-645 and EFJ-745 shown hereon are licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to wind driven rain ratings. 3 3 8 3 4211 6372 10390 7211 99.8 Certified Ratings: 96.6 100.0 99.3 › ‹ Beginning Point of Water Penetration Ratings Wind-Driven Rain Ratings Ventilation Rate (cfm) Free Area 5" 6" Velocity (fpm) (cfm) Pressure Drop (In. Wg.) Florida Building Code Approval 9250 0.22 #13619.1 0.25 - Airflow A 1250 7125 B 1217 10508 1250 9250 A A A Pottorff certifies that model ECD-545, ECD-635, ECD745 and ECV-545 shown hereon are licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to water penetration ratings, air performance and wind driven rain ratings. 1250 1250 1197 1250 › 7" 8375 10018 9625 0.76 0.29 - 0.15 #13619.2 0.53 - 0.50 Certified Ratings: - Pottorff certifies that model ECV-445 shown hereon is licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to wind driven rain and air performance ratings. AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48"x 48" louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. AMCA Wind Driven Rain Ratings based upon a test louver size having 39-3/8” x 39-3/8” core area. 3 Drainable Louvers Drainable blade louvers are designed to prevent water penetration in non-wind-driven rain applications by collecting water in the blade gutters and channeling it into frame downspouts and away from airflow paths. Our ERD-645 incorporates a recessed mullion and downspout that provides the appearance of a continuous drainable blade design. EFD-435 ‹ 4" › ‹ Model Depth Blade Angle EFD-435 4" 35° EFD-245 EFD-437 EFD-445 EFD-637 EFD-645 ERD-645 EFD-245 EFD-445 EFD-645 EFD-437 EFD-637 2" (6063-T5 Ext. Alum.) Drainable 58 9.3 0.081" 4" 37.5° Drainable 6" 37.5° 6" 45° 6" 45° Certified Ratings: ‹ (%) (Sq. Ft.) Thinline-Drainable 45° › Blade Style 45° 4" 4" 6" ERD-645 Drainable Drainable Drainable Recessed-Drainable Free Area 43 6.8 58 9.3 46 7.4 59 9.5 55 8.8 51 8.1 Material 0.081" 0.081" 0.081" 0.081" 0.081" 0.081" 2" 4" 6" › ‹ Beginning Point of Water Penetration Ratings Pressure Drop (In. Wg.) Florida Building Code Approval 8984 0.12 - Airflow 955 6494 903 8398 966 990 990 1050 990 › (cfm) Velocity (fpm) 6" 7425 9405 9240 8059 0.14 - 0.13 #13619.3 0.11 #13619.5 0.14 0.15 0.11 #13619.4 #13619.6 - Pottorff certifies that models EFD-435, EFD-437, EFD-445, EFD-637 and EFD-645 shown hereon are licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. Models EFD-245 and ERD645 are not licensed to bear the AMCA seal. AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48"x 48" louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. 4 Non-Drainable Louvers Available in a wide array of blade shapes and frame depths non-drainable louvers offer value and economy for exhaust applications or intake conditions where protection against water infiltration is not critical. Optional hidden mullions provide a continuous blade appearance on multiple section assemblies. Ideally suited for special shapes and transitional designs. Drainable head louvers blend the aesthetic appeal of a non-drainable blade with the high performance water penetration protection of a drainable blade louver by incorporating a drainable head member to capture water that cascades down the face of the building, channeling it into downspouts and away from the airflow paths. EFJ-430 EFK-430 EFY-245 EFY-445 EFJ-245 EFJ-445 EFK-445 EFJ-645 EFJ-437 EFK-437 EFK-637 EFJ-437-HP EFJ-637-HP 4" (102) ‹ 2" 4" › ‹ Certified Ratings: 4" 6" › ‹ 4" 6" ‹ › 2" 4" 6" › ‹ 4" 6" › Pottorff certifies that models EFJ-437, EFK-437, EFJ-445, EFJ-437-HP and EFK-445 shown hereon are licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. Models EFJ-245, EFY-245, EFJ-430, EFK-430, EFY-445, EFK-637, EFJ-637-HP and EFJ-645 are not licensed to bear the AMCA seal. Model EFJ-245 EFY-245 EFJ-430/EFK-430 EFJ-437/EFK-437 EFJ-445/EFK-445 EFY-445 EFK-637 EFJ-645 EFJ-437-HP EFJ-637-HP Blade Style (6063-T5 Ext. Alum.) (%) (Sq. Ft.) 45° Thinline – Inverted 0.060" 38 6.1 4" 37.5° J/K 6" 45° Inverted Y 45° J Depth 2" 2" 4" 4" Blade Angle 45° 30° 45° 6" 37.5° 4" 37.5° 6" 6" 37.5° Thinline – J J/K J/K K High Performance-J High Performance-J Material 0.060" 0.081" 0.081" 0.081" 0.081" 0.081" 0.081" 0.081" 0.081" Free Area 47 7.5 57 9.1 57 9.1 50 8.0 39 6.2 50 8.0 50 8.0 56 9.0 56 9.0 Beginning Point of Water Penetration Ratings (cfm) Pressure Drop (In. Wg.) Florida Building Code Approval 2336 0.06 - Velocity Airflow 583 4373 889 8090 (fpm) 383 721 689 745 832 800 912 915 6547 5549 4589 6673 6416 8220 8226 0.06 0.09 0.07 - #13619.7/13683.9 0.08 #13619.8/13619.10 0.05 - 0.18 0.10 0.14 0.12 - AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48"x 48" louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. 5 Formed Metal Louvers Typically formed from galvanized steel, these units offer an economical solution for basic ventilation requirements. Optionally available in a wide array of exotic metals including copper and stainless steel our formed metal louvers can also serve to accent building architecture or withstand corrosion in caustic environments. SFJ-430 SFJ-630 SFV-445 ‹ SFK-445 SFJ-245 SFJ-445 SFJ-645 SFK-645 4" › ‹ Model Depth SFJ-430 4" SFJ-245 SFD-445 SFJ-445/SFK-445 SFV-445 SFJ-630 SFD-635 SFJ-645/SFK-645 4" 4" 4" 4" 6" 6" 6" 4" 6" Blade Angle 45° 30° 45° 45° 45° 45° 45° 45° SFD-445 ‹ › Blade Style J J Drainable J/K Chevron J Drainable J 2" 4" 6" ‹ › Material 4" SFD-635 › Free Area (Galvanized Steel) (%) (Sq. Ft.) 20GA 51 8.2 20GA 20GA 20GA 20GA 20GA 20GA 20GA 42 6.7 53 8.5 48 7.7 38 6.1 65 10.4 62 9.9 50 8.0 ‹ 6" › Beginning Point of Water Penetration Ratings (cfm) Pressure Drop (In. Wg.) 6945 0.13 Velocity Airflow 603 4040 715 6092 (fpm) 847 775 600 825 815 800 0.06 0.11 5991 0.13 8580 0.08 3648 8044 6400 0.25 0.08 0.09 The beginning point of water penetration is defined as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48"x 48" louver during a 15 minute period. The water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. 6 Combination/Operable Louvers EXD Combination louvers feature stationary front blades and operable rear blades to ensure proper weather protection when open as well as a consistent appearance in both the open and closed positions. Optional low leakage seals provide further environmental protection in the closed position. Operable blade louvers provide weather protection when open and positive shutoff when no airflow is required. These units incorporate center pivoted blades that can be controlled manually with a pull chain, hand quadrant or hand crank; or automatically with electric or pneumatic actuators. EBE-445 and EBI-445 incorporate backdraft damper blades for automatic shutoff when there is no airflow and can be used for either exhaust and intake applications. EBE-445 EBI-445 Fixed Blade Fixed Blade EOJ-445 EXD-645 Fixed Blade s Fixed Blade EXD-437 s s s 6" ‹ Model EBE-445 EBI-445 EXD-437 EXD-645 EOD-445 EOD-637 EOJ-445 EOJ-637 4" s › ‹ Depth 4" 4" 4" Blade Angle ‹ 37.5° 6" 37.5° 6" J - BD-Intake 0.081" 49 7.9 Combination 45° Operable - Drainable 45° Operable - J Operable - Drainable Operable - J Material ‹ (%) (Sq. Ft.) Combination 6" › (6063-T5 Ext. Alum.) 37.5° 45° 4" Operable Blade Blade Style J-BD-Exhaust 37.5° - 45° 4" › 45° 4" 4" 4" s Gravity Blade s Gravity Blade s (152) 0.081" 0.081" 0.081" 0.081" 0.081" 0.081" 0.081" Free Area 49 7.9 45 7.2 › Operable Blade ‹ Pressure Drop (In. Wg.) 5396 0.10 Airflow 689 5396 1161 8359 (fpm) 689 58 9.2 990 56 9.0 (cfm) Velocity 1050 49 7.9 › Beginning Point of Water Penetration Ratings 44 7.1 49 6.9 4" 1024 683 810 7455 7096 9108 5396 7282 0.10 0.16 0.19 0.16 0.11 0.10 0.12 The beginning point of water penetration is defined as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48"x 48" louver during a 15 minute period. The water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. 7 Acoustical Louvers Recommended for installation in noisy environments, acoustical louvers incorporate insulated blades that restrict sound transmission through the louver over a wide range of frequencies. Our airfoil blade designs offer lower static pressure loss and softer aesthetics for critical airflow performance applications. Certified Ratings: Pottorff certifies that models SAJ835, SAJ-1235, EAA-845 and FAA1245, shown hereon is licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. Models EAA-645 and EAA-1245 are not licensed to bear the AMCA seal. SAJ-835 SAJ-1235 EAA-1245 FAA-1245 EAA-645 EAA-845 Taipei County Building, Taipei, Taiwan ‹ Model EAA-645 EAA-845 SAJ-835 SAJ-1235 EAA-1245 FAA-1245 Depth 6" 8" 8" 12" 12" 12" Blade Style Extruded - Airfoil Extruded - Airfoil Formed - J Formed - J Extruded - Airfoil Formed - Airfoil 8" 12" › ‹ 125 11 8 13 15 13 13 Noise Reduction 250 500 1K 2K 11 8 13 17 14 14 13 10 19 22 17 17 16 14 26 27 19 19 › 6" 8" 18 15 28 31 18 18 ‹ Free Area 4K (%) (Sq. Ft.) 13 33 5.3 17 23 28 17 17 30 4.8 33 5.3 31 4.9 26 4.2 26 4.2 12" › Beginning Point of Water Penetration Ratings (cfm) Pressure Drop (In. Wg.) 4611 0.05 Velocity Airflow 980 4704 808 4293 999 4196 (fpm) 870 924 999 4528 4196 0.10 0.07 0.08 0.09 0.09 AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48"x 48" louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. 8 Penthouse Accommodating individual job requirements, penthouses are constructed to virtually any dimension. For added performance and flexibility these units are available with most louver models and include mitered or box corner designs, insulated roof systems, operable and removable sections for equipment access as well as specialty screens and filtration options. The EFD-637-MD-PH is 6" deep with 37-1/2° horizontal blades and the EPJ-445 is 4" deep with 45° blades. EPJ-445 U.S. Embassy, Kazakhstan Boxed Corner Mitered Corner ‹ ‹ Insulation ‹ Support Angle ‹ Model EFD-637-MD-PH EPJ-445 9 Throat Opening Depth 6" 4" Blade Angle 37.5° 45° › ‹ Insulation ‹ Curb (by others) ‹ (6063-T5 Ext. Alum.) (%) (Sq. Ft.) J - Blade 0.081" 51 8.1 0.081" › Throat Opening Blade Style Drainable Material Support Angle Free Area 59 9.5 ‹ Curb (by others) Beginning Point of Water Penetration Ratings (cfm) Pressure Drop (In. Wg.) 5549 0.08 Velocity Airflow 990 9405 (fpm) 689 0.11 Sight Screens Whether the design calls for total sight concealment, partial screening, high volume airflow, specialty shapes, or thermal shading our sight screens are engineered to meet the most stringent project parameters while satisfying exacting aesthetic requirements. The unique concealed support system of the HT-401 ensures proper structural support and a true continuous blade look without the use of unsightly frames or vertical angles. ‹ HZ-200 6" › VV-400 plan view Horizontal - Inverted J 50 4" Horizontal - Airfoil Tube 2-1/2" Vertical - Cladding VT-654 4" 4" 5" Horizontal - Cladding Vertical - Cladding Vertical - V Vertical - V › 4" ‹ ‹ Free Area (%) Horizontal - Inverted J 2-1/4" VV-500 Blade Style 4" HZ-200 VV-400 4" › 5" › HJ-645 VT-250 ‹ HT-401 plan view 4" Blade Depth HT-401 ‹ plan view Model HJ-445 21/4" VV-500 ‹ ‹ › 21/2 " › VT-654 VT-250 plan view 4" 6" ‹ HJ-445 HJ-645 50 60 19 24 21 39 54 Longo Toyota Parking Structure, Los Angeles, CA 10 Finishes Our superior performance paint systems are available in a wide range of colors and we can also custom color match to any of your specifications. Our expertise in applying architectural coatings assures you of a quality finish. With our options, you get the color you need when you need it! PRODUCT FACTS Finish Type Description/Application Color Selection Warranty 2-coat Polyester Powder Coat Meets AAMA 2604. Dry film thickness 2 mil. Equivalent to Baked Enamel. Environmentally friendly powder coating has good color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. 20 standard colors for aluminum products and acoustical louvers, 18 colors for steel. Custom colors are available. Consult factory. 5 Years Champagne; Light, Medium or Dark Bronze; Black 5 Years Clear Anodize 215 R-1 AA-M10C22A41 (>0.7 mil) Electrochemically oxidized aluminum surface for uniform clear finish. More resistant to natural oxidizing. Improved luster and less glossy than mill finish. Clear 5 Years Aluminum or Galvanized Steel. Normal weathering will occur. N/A 2-coat 100% Fluoropolymer Newlar/Decaflon Meets AAMA 2605. Dry film thickness 2 mil. Equivalent to Kynar 500®/Hylar 5000®, Duranar®, Fluoropon® Integral Color Anodize AA-M10C22A42 (>0.7 mil) Alkyd Prime Coat Mill Our premier finish for extruded aluminum. Tough, long lasting, environmentally friendly powder coating has superior color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Electrochemically deposited inorganic color pigment which is sealed to convert an aluminum oxidation into a corrosion resistant finish. Some shade variation will occur. Standard Colors: 20 standard colors plus Premium Pearl finishes. Custom colors are available. Consult factory. Preparation for field applied epoxy, vinyl, urethane, or N/A other heavy-duty coatings. Must be finished within 60 months of application. Contamination can occur in transmit and in the field; requires field cleaning prior to painting. 5 Years (consult factory for availability of extended warranty up to 20 years). N/A N/A Finishes enhance louver appearance by matching or contrasting with adjacent surfaces and extend weather resistance. Color matching is available upon request. 5101 Blue Mound Road, Fort Worth, Texas 76106 • Phone: 817-509-2300 • Fax: 817-831-3110 • www.pottorff.com • [email protected] PLB October 2012
Similar documents
louvers - Pottorff
period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pott...
More information