louvers - Pottorff
Transcription
louvers - Pottorff
LOUVERS ACOUSTICAL • COMBINATION • DRAINABLE • FLORIDA BUILDING CODE FORMED METAL • MIAMI-DADE • NON-DRAINABLE • OPERABLE • WIND-DRIVEN RAIN PENTHOUSES • SEVERE DUTY • SIGHT SCREENS POTTORFF IS: Innovation, quality, performance and service are what differentiate Pottorff’s products among the competition. Founded in 1928, we are one of the most respected suppliers in the industry today. It is our experience, versatility, and ability to react quickly to our customer’s needs which makes us the choice for architects and engineers. HOW WE ARE DIFFERENT FROM THE COMPETITION: ■■ Ongoing commitment to personal and technical service ■■ Wide range of quality products ■■ Products delivered on time and on budget ■■ Louver Information and Selection Tool ■■ Innovative solutions for your design requirements ■■ Skilled engineering staff for structural design analysis ■■ Quick ship - when you need it FAST! ■■ Industry leading 5-year warranty ■■ Member of the US Green Building Council PRODUCT SELECTION GUIDE MODEL DEPTH NON-DRAINABLE LOUVERS EFJ-245 2" EFJ-430 4" EFJ-437-HP 4" EFJ-637-HP 6" EFJ-645 6" EFK-430 4" EFK-637 6" EFY-245 2" EFY-445 4" DRAINABLE LOUVERS EDD-445 4" EDD-637 6" EFD-245 2" EFD-435 4" EFD-445 4" ERD-645 6" WIND-DRIVEN RAIN LOUVERS ECD-245 2" ECD-445 4" ECD-635 6" ECD-745 7" ECV-245 2" ECV-445 4" ECV-545 5" EFJ-745 7" FLORIDA BUILDING CODE ECD-545 5" ECV-645 6" EFD-437 4" EFD-637 6" EFD-645 6" EFJ-437 4" EFJ-445 4" EFK-437 4" EFK-445 4" MIAMI-DADE LOUVERS ECD-545-MD 5" ECV-645-MD 6" EFD-637-MD 6" FEMA GRILLES XAV-545 5.5" XSV-845 8" BLADE ANGLE BLADE STYLE FREE AREA VELOCITY (fpm) AIR VOLUME 45° 30° 37.5° 37.5° 45° 30° 37.5° 45° 45° J J HIGH PERFORMANCE J HIGH PERFORMANCE J J K K INVERTED Y INVERTED Y 46.9% 56.9% 56.3% 56.3% 50.0% 56.9% 50.0% 38.2% 38.8% 583 889 912 915 800 889 832 383 745 4373 8090 8220 8226 6416 8090 6673 2336 4589 45° 37.5° 45° 35° 45° 45° DUAL DRAINABLE DUAL DRAINABLE DRAINABLE DRAINABLE DRAINABLE RECESSED-DRAINABLE 50.4% 57.5% 42.5% 58.1% 50.4% 50.6% 1026 1113 955 966 1026 990 8311 10242 6494 8984 8311 8059 45° 45° 35° 45° 45° 45° 45° 45° HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL VERTICAL VERTICAL VERTICAL HORIZONTAL J 41.3% 43.3% 53.8% 50.6% 41.5% 42.9% 41.9% 43.8% 1172 1250 1217 1218 1250 1250 1250 1250 7744 8585 10508 9866 8299 8575 8375 8755 ● 45° 45° 37.5° 37.5° 45° 37.5° 45° 37.5° 45° HORIZONTAL VERTICAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL 46.3% 46.0% 58.1% 57.5% 55.0% 56.9% 50.0% 56.9% 50.0% 1250 1250 903 1113 1050 721 689 721 689 9250 9250 8398 10242 9240 6547 5549 6547 5549 ● 45° 45° 37.5° HORIZONTAL VERTICAL HORIZONTAL 41.9% 46.0% 54.6% 1250 1250 1100 8388 9250 9600 ● – – HORIZONTAL HORIZONTAL 49.0% 58.5% 555 – 4385 – ● 1 (cfm) AMCA CERT – – ● – – – – – – ● ● – ● ● – ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● PAGE 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 6 7 7 7 7 7 7 7 7 7 7 8 8 8 8 8 8 8 PRODUCT SELECTION GUIDE (CONT) MODEL OPERABLE LOUVERS EOD-445 EOD-637 EOJ-445 EOJ-637 SOJ-445 COMBINATION LOUVERS EBE-445 EBI-445 EXA-645 EXD-645 FORMED METAL LOUVERS SBE-245 SBE-445 SBI-445 SFD-445 SFD-635 SFJ-245 SFJ-430 SFJ-445 SFJ-630 SFJ-645 SFK-445 SFK-645 SFV-445 ACOUSTICAL LOUVERS EAA-645 EAA-845 EAA-1245 EAJ-437 EAJ-637 FAA-1245 SAJ-835 SAJ-1235 SPECIALTY LOUVERS EBV-145 EBV-445 EVS-422 PENTHOUSES EFD-637-MD-PH EPJ-445 SIGHT SCREENS HJ-445 HJ-645 HT-401 HZ-200 VT-250 VT-654 VV-400 VV-500 AIR VOLUME DEPTH BLADE ANGLE BLADE STYLE FREE AREA VELOCITY 4" 6" 4" 6" 4" 45° 37.5° 45° 37.5° 45° OPERABLE–DRAINABLE OPERABLE–DRAINABLE OPERABLE–J OPERABLE–J FORMED OPERABLE–J 43.1% 57.5% 49.4% 56.3% 46.9% 1024 990 683 810 775 7096 9108 5396 7282 5813 – – – – – 4" 4" 6" 6" 45° 45° 37.5°– 45° 37.5°– 45° J-BD-EXHAUST J-BD-INTAKE COMBINATION COMBINATION 49.4% 49.4% 50.4% 44.4% 689 689 1085 1050 5396 5396 8756 7455 – – 2" 4" 4" 4" 6" 2" 4" 4" 6" 6" 4" 6" 4" 45° 45° 45° 45° 35° 45° 30° 45° 30° 45° 45° 45° 45° J-BD-EXHAUST J-BD-EXHAUST J-BD-INTAKE DRAINABLE DRAINABLE J J J J J K K CHEVRON 41.0% 46.9% 46.9% 53.1% 61.7% 42.0% 51.0% 48.0% 65.2% 50.0% 48.0% 50.0% 38.0% 383 775 775 715 815 603 847 775 825 800 775 800 600 2528 5813 5813 6092 8044 4040 6945 5991 8580 6400 5991 6400 3648 6" 8" 12" 4" 6" 12" 8" 12" 45° 45° 45° 37° 37° 45° 35° 35° AIRFOIL AIRFOIL AIRFOIL J J FORMED AIRFOIL FORMED-J FORMED-J 30.0% 36.9% 26.3% 33.8% 32.5% 26.3% 33.1% 30.6% 980 772 999 740 890 999 808 924 4704 4564 4196 3996 4637 4196 4293 4528 1.5" 4" 4" 45° 45° 22° J J VERTICAL – – 15.6% – – 1250 – – 3125 – – – 6" 4" 37.5° 45° HORIZONTAL J 54.6% 50.0% 1100 689 9600 5549 – – 4" 6" 4" 2.25" 2.5" 4" 4" 5" 45° 45° – 45° – – – – HORIZONTAL-INVERTED-J HORIZONTAL-INVERTED-J HORIZONTAL AIRFOIL HORIZONTAL CLADDING VERTICAL-CLADDING VERTICAL-CLADDING VERTICAL-V VERTICAL-V 50.6% 50.0% 60.0% 19.4% 24.4% 21.0% 38.8% 53.8% – – – – – – – – – – – – – – – – – – – – – – – – (fpm) (cfm) AMCA CERT ● – – – – – – – – – – – – – – – ● – – – – ● ● PAGE 11 11 11 11 11 11 12 12 12 12 12 13 13 13 13 13 13 13 13 13 13 13 13 13 13 14 14 14 14 14 14 14 14 14 15 15 15 15 15 15 15 16 16 16 16 16 16 16 16 16 Cover Photos: Top Left: Campbell Landings | St. Petersburg, Florida | ECD-545 Top Center: W Hotel | Hoboken, New Jersey | ECD-545 Top Right: Methodist Hospital for Surgery | Addison, Texas | EFD-445 Middle Left: T-Mobile | Irvine, California | SFJ-445 Center: Bank Of America | Richmond, Virginia | EFD-637-MD Bottom Left: DuPont Fabros | Ashburn, Virginia | ECD-545 Bottom Center: Oakmonte Villages | St. Mary, Florida | ECD-645-MD, EFD-637-MD Bottom Right: Detail, Methodist Hospital for Surgery | Addison, Texas | EFD-445 2 ANATOMY OF A LOUVER A louver is a device comprised of multiple blades that, when mounted in an opening, permits flow of air but inhibits the entrance of other elements. Louvers are typically fabricated from formed steel or extruded aluminum. HEAD Top of the louver and completes the connection between the jambs BLADE Varies in shapes, sizes and blade angles to serve different purposes DRIP Top of the louver that fills the gap between head and top blade. Equipped with a drainable channel BLADE ANGLE JAMB The lower or flatter the blade angle, the easier it is to get air into the building Structural support for the blades as well as channels water for drainable louvers SILL Base of the louver BLADE STYLES DRAINABLE BLADE J BLADE K BLADE CHEVRON BLADE INVERTED Y BLADE A drainable blade is equipped with a gutter to channel water toward the jambs of the louver and away from the airflow. The J Blade has a smooth flat profile devoid of a gutter on the leading edge. The K blade has an offset step in its profile acting as a rain trap. The K style blade can be drainable or non-drainable. The Chevron blade combines closed sight lines and drainability. With a C shaped hook at the top, it is the primary choice to stop wind-driven rain. An Inverted Y or V blade is intended for sight proof applications. With the closed sightlines, sacrifices in free area performance and greater pressure drop are made. 3 NON-DRAINABLE LOUVERS Available in a wide array of blade shapes and frame depths, non-drainable louvers offer value and economy for exhaust applications or intake conditions where protection against water infiltration is not critical. Optional hidden mullions provide a continuous blade appearance on multiple section assemblies. Ideally suited for special shapes and transitional designs. NON-DRAINABLE EFJ-245 EFJ-645 EFJ-430 EFK-430 2" 6" DRAINABLE HEAD EFK-637 EFY-245 EFY-445 2" 4" 6" 4" EFJ-437-HP EFJ-637-HP 4" 6" EFJ-245 EFJ-430 EFJ-437-HP EFJ-637-HP EFJ-645 EFK-430 EFK-637 EFY-245 EFY-445 J J HIGH PERFORMANCE-J HIGH PERFORMANCE-J J K K INVERTED Y INVERTED Y Certified Ratings: Pottorff certifies that model EFJ-437-HP, shown herein is licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. 4 46.9% 56.9% 56.3% 56.3% 50.0% 56.9% 50.0% 38.2% 38.8% 7.5 9.1 9.0 9.0 8.0 9.1 8.0 6.1 6.2 583 889 912 915 800 889 832 383 745 4373 8090 8220 8226 6416 8090 6673 2336 4589 (In UR .W E g. ) 45° 30° 37.5° 37.5° 45° 30° 37.5° 45° 45° (%) (Sq. Ft.) DRPRE OP SS 2" 4" 4" 6" 6" 4" 6" 2" 4" FREE AREA R BLADE STYLE (c FLO fm W ) BLADE ANGLE AI DEPTH VE MODEL L (fp OC m ITY ) BEGINNING POINT OF WATER PENETRATION RATINGS 0.06 0.09 0.14 0.12 0.10 0.09 0.05 0.06 0.18 AMCA CERT. – – ● – – – – – – DRAINABLE LOUVERS Drainable blade louvers are designed to reduce water penetration in non-wind-driven rain applications by collecting water in the blade gutters and channeling it into frame downspouts and away from airflow paths. Available in a wide array of blade shapes and frame depths, non-drainable louvers offer value and economy for EDD-445 EFD-445 EDD-637 4" exhaust applications or intake conditions where protection against water infiltration is not critical. Optional hidden mullions provide a continuous blade appearance on multiple section assemblies. Ideally suited for special shapes and transitional designs. EFD-245 EFD-435 ERD-645 2" 6" 4" 6" 50.4% 57.5% 42.5% 58.1% 50.4% 50.6% 8.1 9.2 6.8 9.3 8.1 8.1 1026 1113 955 966 1026 990 8311 10242 6494 8984 8311 8059 ) g. (In .W DRPRE OP SS U LO W DUAL-DRAINABLE DUAL-DRAINABLE DRAINABLE DRAINABLE DRAINABLE RECESSED-DRAINABLE ) 45° 37.5° 45° 35° 45° 45° fm 4" 6" 2" 4" 4" 6" (%) (Sq. Ft.) RF EDD-445 EDD-637 EFD-245 EFD-435 EFD-445 ERD-645 FREE AREA (c BLADE STYLE AI ANGLE (fp DEPTH VE MODEL LO C m IT ) Y RE BEGINNING POINT OF WATER PENETRATION RATINGS 0.16 0.15 0.14 0.12 0.16 0.11 AMCA CERT. ● ● – ● ● – Certified Ratings: Pottorff certifies that models EDD-445, EDD-637, EFD-435, and EFD-445, shown herein are licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48" x 48" louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. 5 WIND–DRIVEN RAIN LOUVERS Our wind-driven rain louvers offer exceptional protection under the most severe conditions and are available in frame depths from 2" to 7". The closely spaced vertical blade design of the ECV-545 provides wind-driven rain performance with 100% effectiveness at wind velocities up to 50 mph and rainfall up to 8 in/hr. When aesthetic requirements demand a more conventional louver profile, our EFJ-745 is the ideal solution. Its horizontal blades, vertically bladed rear screen, and 99.3% effectiveness at 3in/hr as per the AMCA 500-L wind-driven rain test, give the best of both worlds. HORIZONTAL AND VERTICAL BLADES VERTICAL BLADES ECD-745 ECD-245 ECD-445 ECD-635 ECV-245 ECV-445 ECV-545 EFJ-745 J BLADE WITH VERTICAL BLADE REAR SECTION PLAN VIEW PLAN VIEW 2" 4" 7" ECV-245 ECV-445 5" ECV-545 2" 4" 6" 7" 7" BEGINNING POINT OF WATER PENETRATION RATINGS ECD-245 ECD-445 ECD-635 ECD-745 ECV-245 ECV-445 ECV-545 EFJ-745 2" 4" 6" 7" 2" 4" 5" 7" 41.3% 43.3% 53.8% 50.6% 41.5% 42.9% 41.9% 43.8% 6.6 6.9 8.6 8.1 6.6 6.9 6.7 7.0 Certified Ratings: Pottorff certifies that models ECD-245, ECD-445, ECD-635, ECD-745, ECV-245, ECV-445 and ECV-545, shown herein are licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to water penetration, air performance and wind-driven rain ratings. 29/50 29 29 29/50 29/50 29/50 29/50 29 3/8 3 3 3/8 3/8 3/8 3/8 3 99.0/95.0 99.0 99.6 99.6/99.2 99.6/99.3 99.5/99.4 99.9/99.6 99.3 7744 8585 10508 9866 8299 8575 8375 8755 g. ) .W (In W LO ) fm RF (c AI ) LO C m I 1172 1250 1217 1218 1250 1250 1250 1250 DRPRE OP SS U RE A/B A B A A A A A (fp CLASS VE EF 2123/3011 5587 6372 6260/5312 6371/4300 7343/4350 7356/9485 7211 TY (% ) FE RA CT TI IVE O N W LO 45° 45° 35° 45° 45° 45° 45° 45° (%) (Sq. Ft.) ) HORIZ HORIZ HORIZ HORIZ VERT VERT VERT HORIZ J FREE AREA RF BLADE ANGLE (c fm BLADE STYLE AI MODEL DEPTH VE W L IN (m OC D ph IT ) Y RA IN (In FA /H L r) L ES S AMCA 500L TEST 0.37 0.31 0.29 0.57 0.42 0.30 0.25 0.47 AMCA CERT. ● ● ● ● ● ● ● ● Certified Ratings: Pottorff certifies that model EFJ-745 shown herein is licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and wind-driven rain ratings. AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48”x 48” louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. AMCA Wind-driven Rain Ratings based upon a test louver size having 39-3/8” x 39-3/8” core area 6 SEVERE DUTY CERTIFIED LOUVERS The Florida Building Code is a single statewide code developed and maintained by the Florida Building Commission. The code establishes accountability for licensed contractors and designers. It also establishes building code education requirements for all licensees, uniform procedures and quality control in a product approval system. ECD-545 ECV-645 AMCA 540/550 LISTED EFD-437 EFD-637 EFD-645 EFJ-437 EFJ-445 EFK-437 EFK-445 PLAN VIEW 6" 4" 6" 5" 4" 6" HORIZ VERT HORIZ HORIZ HORIZ HORIZ HORIZ HORIZ HORIZ 46.3% 46.0% 58.1% 57.5% 55.0% 56.9% 50.0% 56.9% 50.0% 7.4 7.4 9.3 9.2 8.8 9.1 8.0 9.1 8.0 Certified Ratings: Pottorff certifies that model ECD-545, and ECV-645 shown herein are licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance, water penetration and wind-driven rain ratings. WIND DRVN RAIN WIND DRVN RAIN DRAINABLE DRAINABLE DRAINABLE NON-DRAINABLE NON-DRAINABLE NON-DRAINABLE NON-DRAINABLE 1250 1250 903 1113 1050 721 689 721 689 9250 9250 8398 10242 9240 6547 5549 6547 5549 ) .W (In DRPRE OP SS LO W fm ) RF (c AI ) LO C m I LOUVER DESIGNATION (fp BLADE FREE AREA STYLE (%) (Sq. Ft.) VE MODEL ECD-545 ECV-645 EFD-437 EFD-637 EFD-645 EFJ-437 EFJ-445 EFK-437 EFK-445 BLADE DEPTH ANGLE 45° 5" 45° 6" 37.5° 4" 37.5° 6" 45° 6" 37.5° 4" 45° 4" 37.5° 4" 45° 4" TY g. UR E BEGINNING POINT OF WATER PENETRATION RATINGS 0.24 0.15 0.13 0.15 0.15 0.07 0.08 0.07 0.08 Certified Ratings: Pottorff certifies that model EFD-437, EFD-637, EFD-645, EFJ-437, EFJ-445, EFK-437 and EFK-445 shown herein are licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. DESIGN LOAD (psf) 187 200 200 200 200 187 200 187 200 AMCA AMCA CERT. 540/550 ● – ● ● ● ● ● ● ● ● FLORIDA BUILDING CODE ● – – – – – – – ● ● ● ● ● ● ● ● ● Certified Listing: Pottorff certifies that the model ECV-645 herein is licensed to bear this AMCA listing label. AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48"x 48" louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. AMCA Wind-driven Rain Ratings based upon a test louver size having 39-3/8" x 39-3/8" core area. 7 SEVERE DUTY CERTIFIED LOUVERS Our Miami-Dade/Florida Building Code certified louvers are engineered and tested to withstand extreme loads, debris impact and cyclic fatigue associated with the severe weather effects of hurricanes. Our ECD-545-MD and ECV-645-MD are also listed for Impact Resistance (AMCA 540) and High Velocity Wind-Driven Rain (AMCA 550) as required by the Florida Building Code. Our XSV-845 steel grille is designed to FEMA 320 or 361 guidelines for shelters and safe rooms. It is compliant for wind borne debris in all tornado or hurricane regions in the United States. MIAMI-DADE/FLORIDA BUILDING CODE ECD-545-MD ECV-645-MD AMCA 540/550 LISTED AMCA 540/550 LISTED FEMA GRILLES EFD-637-MD XAV-545 XSV-845 PLAN VIEW 6" ANCHORLESS INSTALLATION The ECD-545-MD and ECV-645-MD feature an installation system option that secures the louver to the wall without the need of anchors. 5" 5.5" 6" 8" Certified Ratings: Pottorff certifies that the model XAV-545 shown herein is licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings seal applies to air performance ratings. NO DAMPER REQUIRED Both models pass the AMCA 550 high velocity, wind-driven rain test without the need of a damper. Certified Ratings: Pottorff certifies that the model XSV-845 shown herein is licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings seal applies to air performance ratings. ECD-545-MD ECV-645-MD EFD-637-MD XAV-545 XSV-845 5" 6" 6" 5.5" 8" 45° 45° 37.5° – – HORIZ VERT HORIZ HORIZ HORIZ 41.9% 6.7 46.0% 7.4 54.6% 8.7 49.0% 7.9 58.5% 9.4 Certified Ratings: Pottorff certifies that models ECD-545-MD and ECV-645-MD shown herein are licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance, water penetration and wind-driven rain ratings. WIND DRVN RAIN WIND DRVN RAIN DRAINABLE FEMA GRILLE FEMA GRILLE 1250 1250 1100 555 – 8388 9250 9600 4385 – ) W n. RF L m OW ) (c f AI m ) LO C LOUVER DESIGNATION (fp BLADE FREE AREA STYLE (%) (Sq. Ft.) VE MODEL BLADE DEPTH ANGLE IT Y g. DRPRE OP SS (I UR E BEGINNING POINT OF WATER PENETRATION RATINGS 0.21 0.15 0.14 0.094 – Certified Ratings: Pottorff certifies that model EFD-637-MD, shown herein is licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. DESIGN LOAD (psf) 150 150 150 300 290 AMCA CERT. FLORIDA AMCA BUILDING 540/550 CODE ● ● ● ● ● ● ● ● ● – – – ● – – Certified Listing: Pottorff certifies that the models ECD-545MD and ECV-645-MD herein are licensed to bear this AMCA listing label. AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48"x 48" louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. AMCA Wind-driven Rain Ratings based upon a test louver size having 39-3/8" x 39-3/8" core area. 8 LOUVER TESTING LABORATORY Pottorff's wind-driven rain and water penetration lab features a 48" vane axial tubular fan providing 55,000 CFM. In front of the outlet is a system of nozzles which are programmed to sequence the pattern of spray. In front of this is a ventilation chamber with ■■ ductwork running to an exhaust fan featuring an airflow nozzle to measure ventilation airflow. Our setup will test louvers per AMCA 500 and 511 with eventual approval for the AMCA CRP program. Wind-Driven Rain Test – Rates the ability of a louver to protect openings behind it from water directed at the louver of speeds up to 50 mph. Published ratings are a statement of the louver's ability to reject simulated rain including wind velocity, effectiveness, penetration class and discharge loss coefficient class. ■■ Water Penetration Test – The Water Penetration test rates the ability of a louver to protect openings behind it from water that cascades down a wall or falls vertically in front of it. This determines the point of water penetration which AMCA defines as at least 0.01 ounces of water during a 15 minute test. The sample tested is also tested for air performance. ■■ Air Performance – Published ratings include a graph for the pressure loss to the louver's free area, the mode tested (intake or exhaust) and a table of the free area based on its size. AIRFLOW REGULATION A series of chambers that regulate airflow MANIFOLD Allows water to fall in front or down the wall of the louver to simulate conditions in the Water Penetration Test VENTILATION FAN Has the ability to produce up to 24,000 cfm of airflow for use in water penetration and air performance tests DRAINAGE CHAMBER Water collected to provide readings for water penetration test LOUVER Louvers are fabricated to a uniform 48" × 48" and placed in an appropriate opening in the drainage chamber wall where tests are performed WET WALL MANIFOLD Allows water to fall down the wall to the face of the louver at a prescribed 4 in. per hour WATER PRESSURE NOZZLES Releases water to simulate WDR rain rates which are tested at 3 and 8 in. rainfall/hr. FAN AND NOZZLES Five nozzles along with the fan, simulate rain, to suit the spread of rain required 9 HUMAN MACHINE INTERFACE All of our testing in our Pottorff Wind-Driven Rain and Water Penetration Laboratory is able to be automated. For this purpose we use a new HMI (Human Machine Interface) which is designed to run any test and continually store the data in our database. THE HMI SOFTWARE ALLOWS US TO: WIND FAN Has the ability to produce up to 55,000 cfm of airflow for use in wind-driven rain testing 10 ■■ Plot the desired points for testing ■■ Start and stop tests automatically ■■ Live view of all data being retrieved at any point during testing. For example: wind speed, differential pressure, etc. ■■ Control any aspect of a test; for example: fan speed, rain nozzle intervals, etc. ■■ Tests automations at our desired data points OPERABLE LOUVERS Operable blade louvers provide weather protection for open and positive shutoff when no airflow is required. These units incorporate center pivoted blades that can be controlled manually with a pull chain, hand quadrant, or hand crank. They can also be controlled automatically with electric or pneumatic actuators. OPERABLE EXTRUDED ALUMINUM EOD-445 EOD-637 EOJ-445 6" 4" OPERABLE FORMED EOJ-637 4" SOJ-445 6" 4" OPERABLE-DRAINABLE OPERABLE-DRAINABLE OPERABLE-J OPERABLE-J OPERABLE-J EXTRUDED ALUMINUM EXTRUDED ALUMINUM EXTRUDED ALUMINUM EXTRUDED ALUMINUM GALVANNEALED STEEL 11 (%) (Sq. Ft.) 43.1% 57.5% 49.4% 56.3% 46.9% 6.9 9.2 7.9 9.0 7.5 1024 990 683 810 775 7096 9108 5396 7282 5813 . W RE g. ) (In FREE AREA DR PR OP ESS U MATERIAL R 4" 6" 4" 6" 4" STYLE (c FLO fm W ) EOD-445 EOD-637 EOJ-445 EOJ-637 SOJ-445 BLADE ANGLE 45° 37.5° 45° 37.5° 45° AI DEPTH VE L (fp OC m I MODEL ) TY BEGINNING POINT OF WATER PENETRATION RATINGS 0.16 0.11 0.10 0.12 0.14 COMBINATION LOUVERS EXD Combination louvers feature stationary front blades and operable rear blades to ensure proper weather protection when open as well as a consistent appearance in both the open and closed positions. Optional low leakage seals provide further environmental protection in the closed position. These units incorporate center pivoted blades EBE-445 that can be controlled manually with a pull chain, hand quadrant or hand crank. They can also be controlled automatically with electric or pneumatic actuators. The EBE-445 and EBI-445 incorporate backdraft damper blades for automatic shutoff when there is no airflow and can be used for either exhaust and intake applications. EBI-445 EXA-645 EXD-645 6.125" 6" 4" 4" Certified Ratings: Pottorff certifies that the model EXA-645 shown herein is licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings seal applies to air performance and water penetration ratings. (%) (Sq. Ft.) 49.4% 49.4% 50.4% 44.4% 7.9 7.9 8.1 7.1 689 689 1085 1050 . W RE g. ) 5396 5396 8756 7455 0.10 0.10 0.11 0.19 (In FREE AREA DR PR OP ESS U 4" 4" 6" 6" BLADE STYLE J-BD-EXHAUST J-BD-INTAKE COMBINATION COMBINATION R (c FLO fm W ) EBE-445 EBI-445 EXA-645 EXD-645 BLADE ANGLE 45° 45° 37.5° – 45° 37.5° – 45° AI DEPTH VE L MODEL (fp OC m ITY ) BEGINNING POINT OF WATER PENETRATION RATINGS AMCA CERT. – – ● – Certified Ratings: Pottorff certifies that the model EXA-645 shown herein is licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings seal applies to air leakage ratings. AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48”x 48” louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. 12 FORMED METAL LOUVERS Typically formed from galvanized steel, these units offer an economical solution for basic ventilation requirements. Available in a wide array of optional metals including copper and stainless steel. Our formed metal louvers can also serve to accent building architecture or withstand corrosion in caustic environments. SBE-245 SBE-445 SBI-445 2" 4" SFD-445 4" 4" SFJ-245 SFJ-445 SFJ-645 SFK-445 SFK-645 SFD-635 SFJ-430 SFJ-630 2" 4" 6" 6" SFV-445 4" 6" 4" SBE-24 5 SBE- 4 4 5 SBI - 4 4 5 SFD - 4 4 5 SFD - 6 35 SFJ -24 5 SFJ - 4 30 SFJ - 4 4 5 SFJ - 6 30 SFJ - 6 4 5 SFK- 4 4 5 SFK- 6 4 5 SF V- 4 4 5 45° 45° 45° 45° 35° 45° 30° 45° 30° 45° 45° 45° 45° J-BD-EXHAUST J-BD-EXHAUST J-BD-INTAKE DRAINABLE DRAINABLE J J J J J K K CHEVRON (%) (Sq. Ft.) 13 41.0% 46.9% 46.9% 53.1% 61.7% 42.0% 51.0% 48.0% 65.2% 50.0% 48.0% 50.0% 38.0% 6.6 7.5 7.5 8.5 9.9 6.7 8.2 7.7 10.4 8.0 7.7 8.0 6.1 383 775 775 715 815 603 847 775 825 800 775 800 600 2528 5813 5813 6092 8044 4040 6945 5991 8580 6400 5991 6400 3648 . W RE g. ) (In 2" 4" 4" 4" 6" 2" 4" 4" 6" 6" 4" 6" 4" FREE AREA DR PR OP ESS U BLADE STYLE (c LO fm W ) BLADE ANGLE AI RF DEPTH VE MODEL L (fp OC m ITY ) BEGINNING POINT OF WATER PENETRATION RATINGS 0.08 0.13 0.14 0.11 0.08 0.06 0.13 0.13 0.08 0.09 0.13 0.09 0.25 ACOUSTICAL LOUVERS Recommended for installation in noisy environments, acoustical louvers incorporate insulated blades that restrict sound transmission through the louver over a range of frequencies. Our airfoil blade designs offer lower static pressure loss and softer aesthetics for critical airflow performance applications. EAA-645 EAA-845 EAA-1245 FAA-1245 EAJ-437 EAJ-637 6" 8" SAJ-835 SAJ-1235 4" 6" 12" 8" 12" 500 1K 2K 4K 6" 8" 12" 4" 6" 12" 8" 12" 45° 45° 45° 37° 37° 45° 35° 35° AIRFOIL AIRFOIL AIRFOIL J J FORMED - AIRFOIL FORMED - J FORMED - J 11 8 13 11 10 13 13 15 11 8 14 10 10 14 13 17 13 10 17 12 12 17 19 22 16 14 19 17 22 19 26 27 18 15 18 18 20 18 28 31 17 13 17 17 19 17 23 28 FREE AREA (%) (Sq. Ft.) 30.0% 36.9% 26.3% 33.8% 32.5% 26.3% 33.1% 30.6% 4.8 5.9 4.2 5.4 5.2 4.2 5.3 4.9 980 772 999 740 890 999 808 924 . W RE g. ) 4704 4564 4196 3996 4637 4196 4293 4528 0.10 0.05 0.09 0.06 0.15 0.09 0.07 0.08 (In 250 DR PR OP ESS U 125 ) W BLADE STYLE m BLADE ANGLE AI R (c FLO f EAA-645 EAA-845 EAA-1245 EAJ-437 EAJ-637 FAA-1245 SAJ-835 SAJ-1235 NOISE REDUCTION DEPTH VE MODEL L (fp OC m ITY ) BEGINNING POINT OF WATER PENETRATION RATINGS AMCA CERT. – ● – – – – ● ● Certified Ratings: Pottorff certifies that models EAA-845, SAJ-835, and SAJ-1235, shown herein are licensed to bear the AMCA seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. AMCA defines the beginning point of water penetration as the free area velocity at the intersection of a simple linear regression of test data and the line of 0.01 ounces of water per square foot of free area and is measured through a 48”x 48” louver during a 15 minute period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pottorff recommends that intake louvers are selected with a reasonable margin of safety below the beginning point of water penetration in order to avoid unwanted penetration during severe storm conditions. 14 SPECIALTY PRODUCTS Brick vents are used primarily on renovation projects. They provide a permanent means of gravity ventilation for crawl spaces, hung ceilings, incinerator rooms, chimney flues, foundations, pipe spaces, and corridors. Our EVS-422 sand louver is ideal for areas or applications that are sensitive to BRICK VENTS EBV-145 EBV-445 wind-driven sand penetration. Penthouses include mitered or box corner designs, insulated roof systems, operable and removable sections for equipment access as well as specialty screens and filtration options. SAND LOUVERS PENTHOUSES EVS-422 EFD-637-MD-PH EPJ-445 4" BOXED CORNER .25" MITERED CORNER 4" EBV-145 EBV-445 EVS-422 PENTHOUSES EFD-637-MD-PH EPJ-445 – – 15.6% 2.5 – – 1250 – – 3125 – – 1.00 37.5° 45° HORIZONTAL J-BLADE 54.6% 8.7 50.0% 8.0 1100 689 9600 5549 0.14 0.08 15 ) fm RF (c AI (%) (Sq. Ft.) g. ) UR E .W (In DRPRE OP SS J J VERTICAL ) 6" 4" W 45° 45° 22° LO 1.5" 4" 4" LO FREE AREA CI BLADE STYLE (fp m DEPTH 4" VE MODEL BLADE ANGLE TY BEGINNING POINT OF WATER PENETRATION RATINGS SIGHT SCREENS Whether the design calls for total sight concealment, partial screening, high volume airflow, specialty shapes, or thermal shading, our sight screens are engineered to meet the most stringent project parameters while satisfying our customer's many different aesthetic requirements. HJ-445 HJ-645 4" 6" VT-250 4" HT-401 VT-654 PLAN VIEW VV-400 HZ-200 2.25" VV-500 PLAN VIEW PLAN VIEW PLAN VIEW 4" 2.5" 4" 5" MODEL DEPTH BLADE ANGLE BLADE HJ-445 HJ-645 HT-401 HZ-200 VT-250 VT-654 VV-400 VV-500 4" 6" 4" 2.25" 2.5" 4" 4" 5" 45° 45° – 45° – – – – HORIZONTAL - INVERTED J HORIZONTAL - INVERTED J HORIZONTAL - AIRFOIL TUBE HORIZONTAL - CLADDING VERTICAL - CLADDING VERTICAL - CLADDING VERTICAL - V VERTICAL - V 16 FREE AREA (%) (Sq. Ft.) 50.6% 50.0% 60.0% 19.4% 24.4% 21.0% 38.8% 53.8% 8.1 8.0 9.6 3.1 3.9 3.4 6.2 8.6 LIST™ (LOUVER INFORMATION AND SELECTION TOOL) Pottorff’s Louver Information and Selection Tool is a state-ofthe-art computer based program that puts key information for louver selection at your fingertips. LIST™ allows engineers and architects to choose the right louver based on application and performance criteria. www.pottorff.com/LIST SELECT LOUVERS BASED ON: LIST™ GIVES YOU THE ABILITY TO: View model, catalog pages and installation instructions Access REVIT models Drop louver selections into a schedule Automatically save your work when interruptions arise Create custom CSI formatted specifications 17 Material Louver Type Blade Type Airflow Velocities Airflow Direction Opening Size Pressure Loss Beginning Point of Water Penetration Free Area AMCA, FBC, Miami-Dade, and FEMA Certifications LOUVER OPTIONS Pottorff offers a complete line of louver options. Whether your project requires special architectural shapes, security burglar bars, flange or frame options, we have the accessories you need. See the back cover for finish options. LOUVER SHAPES SHAPE A B Trapezoid C D Right Triangle E Triangle F Double Slope Top G H Diamond J 1/4 Round K Radius Top L Round M 1/2 Round OPTIONS BURGLAR BARS FILTER RACK GLAZING FRAME LOUVER HINGE SILL/HEAD FLASHING BEST WARRANTY IN THE INDUSTRY To reinforce our reputation for high quality products and dependable service, Pottorff offers an industry leading 5-year warranty on our entire line of louver products. "By backing every product we ship with a 5-year warranty, we reinforce the depth of our commitment to providing customers quality products the first time and every time" says Pat Cockrum, president of Pottorff. 18 STUCCO FLANGE VARIABLE FLANGE FINISHES OPTIONS FINISH TYPE DESCRIPTION/APPLICATION COLOR SELECTION WARRANTY 2-coat 100% Fluoropolymer Powder Coat meets AAMA 2605. Dry film thickness 2 mil. Equivalent to Kynar 500®/Hylar5000®, Duranar®, Fluoropon® Our premier finish for extruded aluminum. Tough, long lasting, environmentally friendly powder coating has superior color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Standard Colors: 20 standard colors plus Premium Pearl finishes. Custom colors are available. Consult factory. 5 Years (consult factory for availability of extended warranty up to 20 years). 2-coat Polyester Powder Coat meets AAMA 2604. Dry film thickness 2 mil. Equivalent to Baked Enamel Environmentally friendly powder coating has good color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. 20 standard colors for aluminum products and acoustical louvers, 18 colors for steel. Custom colors are available. Consult factory. 5 Years Integral Color Anodize AA-M10C22A42 (>0.7 mil) Electrochemically deposited inorganic color pigment which is sealed to convert an aluminum oxidation into a corrosion resistant finish. Some shade variation will occur. Champagne; Light, Medium or Dark Bronze; Black 5 Years Clear Anodize 215 R-1 AA-M10C22A41 (>0.7 mil) Electrochemically oxidized aluminum surface for uniform clear finish. More resistant to natural oxidizing. Improved luster and less glossy than mill finish. Clear 5 Years Alkyd Prime Coat Preparation for field applied epoxy, vinyl, urethane, or other heavy-duty coatings. Must be finished within 6 months of application. Contamination can occur in transit and in the field; requires field cleaning prior to painting. N/A N/A Mill Aluminum or Galvanized Steel. Normal weathering will occur. N/A N/A To request a standard color sample or anodized variation sample, please contact customer service. 5101 Blue Mound Road • Fort Worth, Texas 76106 • tel: 817-509-2300 • fax: 817-831-3110 • www.pottorff.com PBL – August 2016
Similar documents
Selection Technical Information Finishes
period. The AMCA water penetration test provides a method for comparing louver models and designs as to their efficiency in resisting the penetration of rainfall under specific lab conditions. Pott...
More information