ProWatch 3 Release 6 Integral DVXi Digital Video Recorder
Transcription
ProWatch 3 Release 6 Integral DVXi Digital Video Recorder
Pro Watch 3 Release 6 Integral DVXi Digital Video Recorder Integration The purpose of this document is to provide the necessary instructions regarding the integration of the Integral Technologies® digital video recording unit with the Prowatch software suite. Checklist: ? Prowatch R6 is installed and functionality declared by successfully executing the ProWatch. ? You have an Integral Technologies® DVR with a programmed static IP address as well as the MasterControl software installed. Instructions are supplied below for verifying IP address programming. ? An available network connection reserved for the Integral Technologies ® DVR. 1.) Verify static IP address programming of the Integral Technologies® DVR by performing the following. ? Log into Windows and right click on My Network Places icon on the desktop of the operating system and select properties. ? Double click on the Local Area Connection icon and select properties. This opens the Local Area Connection Properties. ? Double click on the Internet Protocol (TCP/IP) to verify settings. Apply a static IP address within the Internet Protocol (TCP/IP) Properties 2.) Execute the “MasterControl” software from the desktop ICON or from the Windows Start menu - Start\Programs\Integral\MasterControl. You will be prompted for the username and password in order to gain access to the MasterControl database. Use the following Username and Password. Username = “Administrator” Password = “letmein” This is the default username and password that is used to log into the operating system as well as the MasterControl database. Prior to the full execution\load of the MasterControl software, a system check will be performed to detect any cameras that are physically connected to the Integral DVR unit. By physically connecting all cameras to the Integral DVR prior to executing the MasterControl software, you can eliminate extra steps to initiate Camera Detection. Page 1 of 13 If you apply physical camera connections to the camera inputs on the back of the Integral DVR while the MasterControl software is open, you can either re-execute the MasterControl software and log back in to initiate auto detection, or you can locate and select the “Setup” option located in the upper portion of the MasterControl software in order to initiate Camera Detection. After selecting the Setup option, locate and select the Hardware Tab and select the “Camera Detection” button. Page 2 of 13 By selecting “Camera Detection”, a window containing all available Camera inputs will be displayed. You may select each individual camera or perform a “Rescan” and all connected cameras will display a v in each detected camera’s checkbox after the Rescan has completed. Select the “Accept” option once all cameras have been manually selected or have been detected after a completed Rescan. Page 3 of 13 3.) After the MasterControl software loads, locate and select the “Schedule” option in the upper portion of the MasterControl software. This is where each camera can be individually scheduled or mass camera scheduling can be applied as well based on specific dates and time frames. Below are individual Camera Scheduling Modes and the respective definition of each Mode. Select Modes: Motion (blue) – records video only if motion is detected during the time period you specify on the Schedule page. You can configure MasterControl to detect only the most noticeable activity or any slight movements. This sensitivity can be adjusted on the SETUP page to adjust the motion sensitivity. Alarm (red) – records video only if an alarm is triggered during the time period you specify on the Schedule page. Assigning Cameras can set the maximum duration of the camera’s activation on the Alarms tab on the Setup page to Alarms. Free (green) – records video for the entire length of time you specify on the Schedule page. Page 4 of 13 4.) Prior to activating recording on the Integral DVR unit, you will need to set up scheduling of cameras before recording is initiated. After camera scheduling has been programmed, locate and select the “Record” option in order to initiate recording. ***Important! *** The Record option must be selected in order to view live video via the Prowatch CCTV Camera View(s). Now that scheduling preferences have been applied and the Integral DVR is in RECORD mode, you are ready to apply the necessary programming to Prowatch. ** If there is a pre-existing site configured within Prowatch Hardware Configuration that will be used for the Integral DVR integration, then skip the “Adding a new Site” section and follow the instructions for adding a new channel. Adding a new Site: 1.) Create new site (**if necessary) by right clicking on Prowatch NT Hardware Configuration within the hardware configuration tree and select New> Site. Page 5 of 13 2.) Create the new site by entering the necessary SiteID and Site description followed by the correct workstation definition. Adding an Integral Channel: 1.) Right Click on the newly created site and select New> Channel and select Integral as the Channel Type. Select OK. Page 6 of 13 2.) Type a Description and select the correct TimeZone for your region. Ensure that the installed checkbox is selected before proceeding. Select Next>. 3.) Select the Port Type of TCP/IP and enter the IP Address of the Integral DVR along with the username and password used to access the MasterControl database. The default username and password is listed below. After entering the necessary information within the Communication Parameters tab, select Next> and then Finish. Page 7 of 13 Use the following user account information if the default user account hasn’t changed. Username = “Administrator” Password = “letmein” The Integral channel ICON will display a green colored background, which indicates that communication to the DVR has been established. If the channel ICON appears with a background color of red make sure that the DVR has a static IP address programmed within the Network\TCP/IP properties. Also, verify the Integral DVR TCP/IP properties programming by pinging the IP address of the DVR unit from a machine located on the network. If the channel appears with a color of yyeelllloow w, make sure that the Installed checkbox within the channel properties is selected as well as the correct workstation name has been assigned to the site. Page 8 of 13 You can access the site properties by right clicking on the site name and selecting properties. Check the Workstation: to ensure that the correct workstation name has been applied. If the workstation programming is incorrect, then select the within the site properties to define the correct workstation for this site. If you do not have the correct workstation assignment for any Prowatch configured Site, then channel communications within that site will fail. After site and channel setup are completed for the integration of the Integral DVR, next the software controlled camera views need to be programmed. To start the camera view configuration, open hardware configuration within Prowatch. Right click on the Integral Channel that was created earlier and select New>CCTV Camera View. Page 9 of 13 Enter the Description and Input number (Port) that the camera is connected to on the Integral DVR. Select OK and the CCTV Camera View folder will be created to contain all CCTV Camera Views that are created. In order to view live video via Prowatch Hardware Configuration CCTV Camera Views, select the CCTV Camera Views folder and right click on the camera view of choice to select GO LIVE. This will bring up a Video dialog box containing live video feed from the direction of the camera. Page 10 of 13 After selecting Go Live, a dialog box containing live video feed will display. If after selecting the Go Live option on the CCTV Camera View and there isn’t any live video feed, double check the following: Page 11 of 13 ? Camera has power and is connected to an available camera input on Integral DVR unit. Verification of live video can be performed using the “Setup” option within the MasterControl software as a troubleshooting tool. Toward the bottom of the Setup view, you will notice detected cameras indicated by a numeric value in black. By selecting one of the numbers in black located near the bottom of the Setup view, live video will display. ? Ensure that “Record” is selected within the “Schedule” located in the top main menu of options of the MasterControl software. If not, live video feed will not be displayed via the Prowatch software controlled CCTV Camera View(s). Select Record and test the Prowatch CCTV Camera View functionality for live video feed. ? Verify that you can ping the IP address as well as the computer name of the DVXi unit from the Prowatch server location. If not, network related issues are present and further troubleshooting will be necessary. Page 12 of 13 Below is a list of resources for information and technical support regarding Integral Technologies® Digital Video Recording Solutions Integral Technologies® Website: http://www2.integraltech.com/default.cfm Technical Support Resources: Email: [email protected] Technical Support by Phone: 866.585.0280 or 317.845.9242 Page 13 of 13