airway management products - Novimed
Transcription
airway management products - Novimed
AIRWAY MANAGEMENT PRODUCTS About Hood Laboratories The Hood Bronchial and Tracheal Stents offer Interventional Pulmonologists and Thoracic Surgeons an excellent adjunct to surgical correction and laser resection. Hood Tracheal and Thoracic T-Tubes enable short-term post surgical management of tracheal and subglottic stenosis and the reconstruction of the cervical and thoracic trachea. Many Hood Tracheal products have the added benefit of Ultra-smooth Plus® surface treatment. This proprietary technology modifies the surface properties of silicone. Ultra-smooth Plus® treated silicone creates less edematous adhesions, reduced chance of mucus build-up and granulation, easier post placement management, and is safer for the patient. Special Order Products Hood Laboratories will work with the physician to specialize a Bronchial Stent, Tracheal Stent, Tracheal T-Tube, Y Stent or Stoma Stent to accommodate a patient who may require a unique size. Our staff will work with you personally to design the customized product, providing engineering drawings for your review. Call or fax our Customer Service Department with your design request: Phone 781-826-7573 • Fax 781-826-3899 These products have been manufactured with surface treatment Ultra-smooth Plus® Surface Treatment Many of Hood’s products are treated with Ultra-smooth Plus® Surface Treatment which enhances the surface properties of medical grade polymers without affecting bulk properties. Advantages of Ultra-smooth Plus® • Slippery surface • Extended product life Smooth Less friction than untreated products No need for lubricants • Biocompatibility 1 Improves hydrophilicity Wear resistant Abrasion resistant • Reduced rates of infection and thrombosis Thromboresistant Resistant to biofilm formation Resistant to bacterial and fungal growth 575 Washington Street, Pembroke, MA 02359 800-942-5227 • 781-826-7573 • Fax 781-826-3899 Email: [email protected] • www.hoodlabs.com Hood Stoma Stents* are self-retaining devices used to maintain the patency of a tracheostomy. Made of implant-grade silicone, the Stoma Stents are smooth, flexible, and non-irritating to the skin and the tracheal mucosa. Hood Stoma Stent Systems & Accessories Principal Indications for Stoma Stent use are: 1. Maintenance of long-term or permanent tracheostomy in: Sleep Apnea Bilateral vocal cord paralysis Laryngeal (glottic) insufficiency or stenosis due to trauma, carcinoma, radiation therapy, edema and other diseases. 2. Short-term tracheostomy when assisted respiration is not required. 3. Following removal of cannula or T-Tube until adequate airway is assured or as an alternative to a T-Tube in appropriate cases. * Designed with assistance from Isaac Eliachar, M.D., Cleveland Clinic Foundation A •Easy, safe insertion and removal for cleaning •Minimal encroachment upon tracheal lumen •Reinforced flange to resist spontaneous expulsion in patients with strong coughs •Small external profile for improved cosmetic appearance •Both straight and curved designs are available •Infant through adult sizes B A Standard Stoma Stents Straight Code No. Curved Code No. A A B O.D. (mm) I.D. (mm) Length (mm) SS–0811 8 SS–0813 8 SS–0815 8 SS–0817 8 SS–0819 8 SS–0821 8 SS–0823 8 SS–1111 11 SS–1113CS–111311 SS–1119 CS–1119 11 SS–1122CS–112211 Indicates sizes ordered in a set. 5.5 5.5 5.5 5.5 5.5 5.5 5.5 7.5 7.5 7.5 7.5 11 13 15 17 19 21 23 11 13 19 22 Straight Code No. A Curved Code No. O.D. (mm) A I.D. (mm) B Length (mm) SS–1124 CS–1124 11 7.5 SS–1127CS–1127 11 7.5 SS–0411 CS–0411 11 7.5 SS–1319 CS–1319 13 10 SS–1322CS–1322 13 10 SS–1324 CS–1324 13 10 SS–0213 CS–0213 13 10 SS–1530 15 11.5 SS–1540 15 11.5 SS–1550 15 11.5 Specialized sizes available upon request. 24 27 1 of each length 19, 22, 24, 27 19 22 24 1 of each length 22, 24 30 40 50 B A B Low profile • A great alternative to a tracheostomy tube A B 2 Hood Straight Stoma Stents with Windows and Stoma Stent Introducing Forceps The Hood Straight Stoma Stents with Windows and Stoma Stent Introducing Forceps System has all the same features of the standard Stoma Stents with the additional feature of windows in the neck flange of the stent to accommodate the Stoma Stent Introducing Forceps. The forceps are reusable and designed exclusively for use with specifically designed Hood Straight Stoma Stents with Windows. •Easy, safe insertion and removal for cleaning •Minimal encroachment upon tracheal lumen •Reinforced flange to resist spontaneous expulsion in patients with strong coughs •Small external profile for improved cosmetic appearance 3 The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion technique and postoperative care. Hood Straight Stoma Stents with Windows Code No. A O.D. (mm) B Length (mm) A I.D. (mm) SSW–08118 5.5 SSW–08138 5.5 SSW–08158 5.5 SSW–08178 5.5 SSW–0819 8 5.5 SSW–08218 5.5 SSW–08238 5.5 SSW–1111 117.5 SSW–1113 117.5 11 13 15 17 19 21 23 11 13 Code No. A O.D. (mm) B Length (mm) A A I.D. (mm) B SSW–1119 11 7.5 19 SSW–1122 117.5 22 SSW–1124 11 7.5 24 SSW–1127 117.5 27 SSW–1319 13 10 19 SSW–1322 1310 22 SSW–1324 13 10 24 SSW–1530 1511.5 30 SSW–1540 15 11.5 40 SSW–1550 1511.5 50 280 mm Stoma Stent Introducing Forceps 70 mm Code No. 2 mm SS–Forceps Hood Stoma Stent Accessories for Standard Stoma Stents and Straight Stoma Stents with Windows Eliachar Speaking Valves are low profile, clear silicone speaking valves for use with the Hood Stoma Stents. It allows the wearer to speak without occluding the stoma stent opening. The valves have a very low resistance, flap design and are treated with Ultra-smooth Plus® surface treatment. Eliachar Speaking Valves Code No. LRV– 4008–S LRV– 4011–S LRV– 4013–S LRV– 4015–S Fits 8mm O.D. Stoma Stent Fits 11mm O.D. Stoma Stent Fits 13mm O.D. Stoma Stent Fits 15mm O.D. Stoma Stent Hood Weaning Kit consists of two plugs with holes of differing diameters. Once it has been determined that a patient can be relieved of a tracheostomy, this kit is useful in helping wean a difficult patient from the tracheostomy. By reducing the allowable volume of air through the stoma in a controlled fashion, the patient is forced to use the upper respiratory tract. Hood Stoma Stent Ring Spacers are used to shorten the length of the Stoma Stent in increments of 1 to 2mm without having to physically alter the Stoma Stent. The rings are designed to complement the 8mm,11mm and 13mm Stoma Stents. Hood Weaning Kit SSR–0818mm SSR–0828mm SSR–11111mm SSR–11211mm SSR–13113mm SSR–13213mm Code No. WK–6000 Hood Stoma Stent Ring Code No. A Dimension (I.D.) B Dimension 1mm 2mm 1mm 2mm 1mm 2mm Hood Stoma Gauge can be used to determine the precise depth of the stoma in order to aid the physician in providing a comfortable fit for Hood’s self-retaining Stoma Stents. Hood Stoma Gauge Code No. SG–10 SG–10–SET Patents Applied Set of 6 4 Injury of the upper airway commonly results in stenotic lesions of the larynx, subglottis, and adjacent trachea. Bronchial & Tracheal Stents with Rings & Posts Hood Bronchial Stents are designed to relieve airway complications such as anastomosis and stenosis. The stent may also be used to minimize chronic bronchial strictures. Inserted endoscopically, both ends of the tube are flanged to prevent movement after surgical placement in the bronchus. Hood Tracheal Stents with Posts and Rings are placed in the trachea at the point of stenosis as a palliative technique for tumors causing extrinsic compression of the large airway. It may also be used for patients with benign tracheostenosis. Hood Tracheal Stents with Posts offer physicians an excellent alternative to the traditional approach of surgical correction and YAG laser resection. The posts help prevent migration. These products have been manufactured with surface treatment 5 •Aids in short-term management of airway obstructions •Fabricated of flexible implant-grade silicone, these stents promote normal humidification and phonation •Permits healing and prevents desiccation Bronchial Stents with Rings Code No. A O.D. (mm) B I. D. (mm) Tracheal Stents with Posts Bronchial Stents with Posts C Length (mm) D Flange O.D. (mm) Code No. BS–0613–S 6 4.5 13 7.5 BS–0813–S8 5.5 13 10 BS–1013–S10 8 13 12 BS–0619–S 6 4.5 19 7.5 BS–0819–S 8 5.5 19 10 BS–1019–S 10 8 19 12 BS–0313–S Length 13, 1 each of O.D. 6, 8, 10mm BS–0319–S Length 19, 1 each of O.D. 6, 8, 10mm A O.D. (mm) BSP–1020–S10 BSP–1030–S10 BSP–1040–S 10 BSP–1220–S12 BSP–1230–S12 BSP–1240–S 12 BSP–1250–S12 BSP–1430–S 14 BSP–1440–S 14 BSP–1450–S 14 B Length (mm) A O.D. (mm) B I. D. (mm) C Length (mm) TS–1020–S107.7 TS–1025–S107.7 TS–1030–S107.7 TS–1035–S107.7 TS–1040–S 10 7.7 TS–1045–S 10 7.7 TS–1050–S107.7 TS–1055–S107.7 TS–1060–S107.7 TS–1065–S107.7 TS–1070–S107.7 TS–1075–S107.7 TS–1080–S107.7 TS–1085–S107.7 TS–1090–S 10 7.7 TS–1220–S 12 8.5 TS–1225–S 12 8.5 TS–1230–S 12 8.5 TS–1235–S 12 8.5 TS–1240–S 12 8.5 TS–1245–S 12 8.5 TS–1250–S 12 8.5 TS–1255–S 12 8.5 TS–1260–S 12 8.5 TS–1265–S 12 8.5 TS–1270–S 12 8.5 D Flange O.D. (mm) 2013 2513 3013 3513 40 13 45 13 5013 5513 6013 6513 7013 7513 8013 8513 90 13 20 14 25 14 30 14 35 14 40 14 45 14 50 14 55 14 60 14 65 14 70 14 Code No. A O.D. (mm) B I. D. (mm) C Length (mm) C Length (mm) TSP–1260–S12 TSP–1270–S12 TSP–1370–S13 TSP–1460–S 14 TSP–1470–S 14 TSP–1560–S15 TSP–1640–S 16 TSP–1650–S16 TSP–1660–S16 TSP–1670–S16 TSP–1680–S16 TSP–1850–S18 TSP–1860–S18 TSP–1870–S18 TSP–1880–S18 TSP–1890–S 18 20 30 40 20 30 40 50 30 40 50 Tracheal Stents with Rings Code No. A O.D. (mm) Code No. 60 70 70 60 70 60 40 50 60 70 80 50 60 70 80 90 D Flange O.D. (mm) TS–1275–S 12 8.5 75 14 TS–1280–S 12 8.5 80 14 TS–1285–S 12 8.5 85 14 TS–1290–S 12 8.5 90 14 TS–1420–S 14 10.5 20 16 TS–1425–S 14 10.5 25 16 TS–1430–S 14 10.5 30 16 TS–1435–S 14 10.5 35 16 TS–1440–S 14 10.5 40 16 TS–1445–S 14 10.5 45 16 TS–1450–S 14 10.5 50 16 TS–1455–S 14 10.5 55 16 TS–1460–S 14 10.5 60 16 TS–1465–S 14 10.5 65 16 TS–1470–S 14 10.5 70 16 TS–1475–S 14 10.5 75 16 TS–1480–S 14 10.5 80 16 TS–1485–S 14 10.5 85 16 TS–1490–S 14 10.5 90 16 TS–1630–S1612.53018.5 TS–1660–S1612.56018.5 TS–1850–S 18 14.5 50 20 TS–1870–S 18 14.5 70 20 TS–2060–S2015.56022 TS–2070–S2015.57022 C A D A B 2mm B A 3mm Specialized sizes available upon request. The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion technique and postoperative care. 6 Injury of the upper airway commonly results in stenotic lesions of the larynx, subglottis, and adjacent trachea. Tracheal & Bronchial Stents with Mesh & Posts Hood Tracheal and Bronchial Stents with Mesh and Posts offer physicians an excellent alternative to the traditional approach of surgical correction and YAG laser resection. The device is placed in the trachea at the point of stenosis as a palliative technique for tumors causing extrinsic compression of the large airway. It may also be used for patients with benign tracheostenosis. Bronchial Stents with Mesh & Posts •Internal mesh provides a tear resistant stent for more stable suturing •Aids in normal breathing and speech •Permits healing and prevents desiccation •Fabricated of implant-grade silicone •Posts aid in preventing migration A O.D. (mm) Code No. A Patent Pending 2mm B Length (mm) BSP–1020–M–S1020 BSP–1030–M–S1030 BSP–1040–M–S 10 40 BSP–1220–M–S1220 BSP–1230–M–S1230 BSP–1240–M–S 12 40 BSP–1250–M–S1250 BSP–1430–M–S 14 30 BSP–1440–M–S 14 40 BSP–1450–M–S 14 50 3mm 7 Tracheal Stents with Mesh & Posts B Code No. A O.D. (mm) TSP–1260–M–S12 TSP–1270–M–S12 TSP–1370–M–S13 TSP–1460–M–S 14 TSP–1470–M–S 14 TSP–1560–M–S15 TSP–1640–M–S 16 TSP–1650–M–S16 TSP–1660–M–S16 TSP–1670–M–S16 TSP–1680–M–S16 TSP–1850–M–S18 TSP–1860–M–S18 TSP–1870–M–S18 TSP–1880–M–S18 TSP–1890–M–S 18 B Length (mm) 60 70 70 60 70 60 40 50 60 70 80 50 60 70 80 90 The Hood Hour Glass Stents with Posts and Reducing Diameter Stents with Posts offer physicians an excellent alternative to the traditional approach of surgical correction and YAG laser. The unique shapes address challenges in treating tracheal stenosis. Reducing Diameter & Hour Glass Stents The stent is placed in the trachea at the point of stenosis as a palliative technique for tumors, causing extrinsic compression of the large airway. It may also be used for patients with benign tracheostenosis. •Aids in normal breathing and speech •Permits healing and prevents desiccation •Fabricated of implant-grade silicone •Posts aid in preventing migration Reducing Ends Stents with Posts B (mm) A&C (mm) Code No. O.D. 1 (mm) Hour Glass Stents with Posts O.D. 2 (mm) TSPR–1210–S15 20 10 12 TSPR–1412–S 15 20 12 14 TSPR–1614–S 15 20 14 16 O.D. 2 O.D. 1 A B Code No. A O.D. (mm) B O.D. (mm) 12 14 15 16 10 12 13 14 HGS–1210–S HGS–1412–S HGS–1513–S HGS–1614–S Reducing Diameter Stents with Posts Code No. RTP–10–8–S RTP–12–8–S RTP–12–10–S RTP–14–8–S RTP–14–10–S RTP–14–12–S RTP–16–10–S O.D. 1 C A B 15mm 20mm 2mm 15mm A O.D. (mm) B O. D. (mm) C (mm) D (mm) 10 12 12 14 14 14 16 8 8 10 8 10 12 10 25 25 40 31 29 22 28 15 14 17 14 20 31 19 D C B A 3mm 2mm C A 3mm These products have been manufactured with surface treatment The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion technique and postoperative care. Special Order Reducing Diameter & Hour Glass Stents are available. See page 1 for information. 8 Y Stents aid in short-term management of airway obstructions. They improve normal breathing and speech, permit healing, and help prevent desiccation. Y Stents The Hood Y and Harrell Y Stents are designed to relieve airway complications such as anastomosis and stenosis. The stent may also be used to minimize chronic bronchial strictures due to tuberculosis and malignancies. The Harrell Y Stent posts help prevent migration of the stent after placement. The Hood Westaby T-Y Stents aid in short-term management of airway obstructions from tracheal tumors, compressions, burns or disease below the thoracic inlet. The design combines bifurcated and T limbs in a single tube to restore patency of major airways and to provide relief from asphyxia. The stent has been used in patients with severe and diffuse scalding injury to the trachea and main bronchi, and with obstruction from tracheal and mediastinal tumors below the thoracic inlet. This stent is flexible, comfortable and non-reactive to tissue, ensuring safe and effective relief within the distal trachea, carina and main bronchi. The 20° angle in T-stem facilitates insertion and cleaning. 9 •The Y Stents angles are anatomically designed to fit the typical carina •Fabricated of implant-grade silicone •Will not harden and are non-reactive and non-irritating •The Y stents allow for normal humidification and phonation O.D. 1 A Hood Y Stents Code No. O.D. 1 (mm) O.D.2 (mm) A B C Y–10–S Y–12–S YS–14–S YM–14–S 10 12 14 14 7 9.5 10 10 45 65 55 61 20 27 17 15 40 50 25 44 O.D. 2 HYP–12–S HYPS–14–S HYP–14–S HYPS–16–S HYP–16–S 12 14 14 16 16 30° 50° O. D. 1 2mm A O.D.2 (mm) O.D. 2 B Limb angle: Y–10 =15° Y–12 =15° YS–14 = 30° YM–14 = 30° Harrell Y Stents with Posts O.D. 1 (mm) C B Special Order Y Stents are available. See page 1. Code No. O.D. 1 size corresponds to outside diameter of intratracheal limb in millimeters. B C 20 20 25 25 30 30 35 35 30 40 3mm A 9.5 9.5 12 12 10 50 50 50 45 50 * Designed with assistance from James H. Harrell II, M.D., University of California at San Diego C B O. D. 2 O. D. 2 Special Order Harrell Y Stents with Posts are available. See page 1. 15 ° 50° O.D. 1 Westaby T–Y Stents Code No. O.D. 1 (mm) O.D.2 (mm) A B C D E RTY–10–S RTY–12–S RTY–14–S RTY–18–S 10 12 14 18 7 9.5 11 14 48 66 79 90 20 27 32 16 40 50 57 58 18 31 29 42 12 20 24 21 B C * Stephen Westaby, B.Sc., M.B., F.R.C.S., M.S. John Radcliffe Hospital, Oxford, U.K. A These products have been manufactured with surface treatment Our engineers and staff will work with you personally to fabricate a specialized product when our standard products do not address the anatomical needs of your patient. Call our Customer Service Department to discuss your specialized needs. See page 1 for details. D E O.D. 2 The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion technique and postoperative care. Patent Applied 10 T-Tubes Hood Radiopaque T-Tubes are designed to maintain short-term patency of the tracheal airway and provide respiration through the larynx. Radiopaque T-Tubes enable visualization following surgery and allow verification of placement of the device. They permit secure placement of the device to maintain the airway in acute injuries and to support the resected trachea. Fabricated of radiopaque silicone, these T-Tubes are flexible and non-abrasive to assure patient comfort. Hood Pediatric Standard Tracheal T-Tubes The extraluminal limb of the Pediatric T-Tubes has an enlarged tip which allows for easier handling of the plug, improved visualization and easier access for maintenance by medical personnel. The Ring Flanged Plug is detached and threaded over the extraluminal limb to fit snugly against the patient’s tracheostoma. Ringed T-Tubes offer the same features of the Hood Standard T-Tube with the option of rings on the horizontal limb for a no-slip fit. The ring flange easily adjusts to neck size. Offered in standard and radiopaque versions. Angled Stem T-Tubes with or without Rings offer the same features of the Hood Standard T-Tube with an angled horizontal limb. This limb is designed to accommodate patients with an angled stoma to ensure a more comfortable fit. 11 •Fabricated of implant-grade silicone material, T-Tubes will not harden, and are non-reactive and non-irritating •Allows for normal humidification and phonation •The smooth extraluminal stem provides comfort for a wide range of patients, thin to obese, and eliminates complications in cases of edema Radiopaque Standard Tracheal T-Tubes Code No. O.D. Size A (mm) B C D RST–06–S 6 10 6 48 5 RST–07–S 7 13 9 48 6 RST–08–S8 1612 366 RST–09–S 9 19 15 40 8 RST–10–S 10 23 17 44 8 RST–11–S 11 27 20 50 9 RST–12–S123121 5511 RST–13–S133122 6011 RST–14–S 14 32 23 64 11 RST–15–S 15 34 24 64 11 RST–16–S163123 6312 Pediatric & Standard Tracheal T-Tubes Code No. O.D. Size (mm) A B C D ST–506–S 6 10 6 48 5 ST–507–S 7 13 9 48 6 ST–508–S 8 16 12 366 ST–509–S 9 19 15 40 8 ST–510–S 10 23 17 44 8 ST–511–S 11 27 20 50 9 ST–512–S 1231 215511 ST–513–S 1331 226011 ST–514–S 14 32 23 64 11 ST–515–S 15 34 24 64 11 ST–516–S 1631 236312 Radiopaque Long Tracheal T-Tubes Code No. O.D. Size (mm) RLT–06–S RLT–07–S RLT–08–S RLT–09–S RLT–10–S RLT–11–S RLT–12–S RLT–13–S RLT–14–S RLT–16–S RLT–18–S A 6 7 8 9 10 11 12 13 14 16 18 B Radiopaque Thoracic T-Tubes (extra-long) C 34 7 40 8 58 12 63 14 63 17 62 17 72 20 72 20 72 23 81 24 81 24 D 48 5 48 6 39 6.5 43 8 508 55 9 59 11 6811 66 11 70 12 55 14 Code No. RELT–08–S RELT–10–S RELT–12–S RELT–14–S O.D. Size (mm) A B C D 8 10 12 14 60 68 98 97 49 48 39 48 40 41 64 74 6.5 8 11 11 These tubes are designed to be cut to desired lengths but care must be taken to trim and smooth the cut edges. Custom-cut lengths are available upon request. Angled Stem T-Tubes Ringed T-Tubes Code No. O.D. Size (mm) A B C D RTR–11–S RTR–12–S RTR–13–S RTR–14–S RTR–15–S 11 12 13 14 15 93 93 93 93 93 39 39 39 39 39 60 60 60 60 60 10 11 11 12 11 Code No. O.D. Size (mm) AST–10–S AST–12–S AST–14–S A B C D 10 23 20 388.0 12 32 26 50 9.5 14 34 32 57 11.0 Extra plugs available upon request. Angled Stem T-Tubes with Rings B Code No. O.D. Size (mm) C ASTR–08–S ASTR–10–S ASTR–12–S ASTR–14–S D 8 10 12 14 A B C D 42 39 42 47 45 39 42 47 45 52 49 51 8.0 8.5 11.0 12.0 A Indicates pediatric sizes. O. D. of Intratracheal Limb These products have been manufactured with surface treatment The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion technique and postoperative care. Patents Applied 12 T-Tubes Hood Tracheal and Thoracic T-Tubes enable short-term surgical management of tracheal and subglottic stenosis and the reconstruction of cervical and thoracic trachea. These patented devices are designed to maintain patency of the tracheal airway and to provide respiration through the larynx. Hood T-Tubes with Rings have rings added to provide additional support in situations where migration may be a concern. Hood Reducing Diameter T-Tubes are designed to allow more options in situations where the proximal tracheal structure differs from the distal dimensions. Tracheal T-Tubes with standard and long limbs serve as both a tracheotomy tube and a tracheal stent. Thoracic T-Tubes are designed with extra-long limbs to bypass and stent a tracheal stenosis between the thoracic inlet and the carina. 13 •The T-Tubes, made of implant-grade silicone material, will not harden, and are non-reactive and non-irritating to ensure patient comfort •They allow for normal humidification and phonation Long Tracheal T-Tubes Reducing Diameter T-Tubes Code No. B C O.D. Size (mm) HTT–11–8–S 11 HTT–12–10–S 12 HTT–13–10–S 13 HTT–14–12–S 14 HTT–16–12–S 16 D A A B C D 38 27 5311 43 60 53 11 31 39 52 13 25 12 49 14 15 11 49 16 O. D. of Intratracheal Limb Reducing Diameter T-Tubes with Rings B Code No. C O.D. Size (mm) A B C D HTTR–10–8–S 10 7878 70 8 HTTR–13–10–S 13 7878 70 11 D A Code No. O.D. Size (mm) LT–506–S 6 LT–507–S 7 LT–508–S 8 LT–509–S 9 LT–510–S 10 LT–511–S 11 LT–512–S 12 LT–513–S 13 LT–514–S 14 LT–516–S 16 LT–518–S 18 A B C D 34 7 48 5 40 8 48 6 58 12 39 6.5 63 14 43 8 631750 8 62 17 55 9 72 20 59 11 722068 11 72 23 66 11 81 24 70 12 81 24 55 14 Thoracic T-Tubes (extra-long tubes with free standing plug) Code No. O.D. Size (mm) ELT–06–S ELT–07–S ELT–08–S ELT–10–S ELT–12–S ELT–14–S 6 7 8 10 12 14 A B C D 40 40 60 68 98 97 30 30 49 48 39 48 48 48 40 41 64 74 5 6 6.5 8 11 11 Additional plugs available upon request. Indicates pediatric sizes. Our engineers and staff will work with you personally to fabricate a specialized product when our standard products do not address the anatomical needs of your patient. Call our Customer Service Department to discuss your specialized needs. See page 1 for details. These products have been manufactured with surface treatment The Hood Intended Use and Instruction Manual, which is supplied with each product, provides detailed information on insertion technique and postoperative care. Patents Applied 14 Vertrieb in der Schweiz: Distributeur pour la Suisse: Novimed AG Medizintechnik CH-8953 Dietikon Heimstrasse 46 Telefon +41 (0)44 743 40 60 Telefax +41 (0)44 743 40 65 [email protected] www.novimed.ch 575 Washington Street, Pembroke, MA 02359 800-942-5227 • 781-826-7573 • Fax 781-826-3899 Email: [email protected] • www.hoodlabs.com F973G056 Rev. 3/13
Similar documents
Doyle Shark Nasal Splints
• Sleep Apnea • Bilateral vocal cord paralysis • Laryngeal (glottic) insufficiency or stenosis due to trauma, carcinoma, radiation therapy, edema and other diseases 2. Short-term tracheostomy when...
More information