UX SERIES - Decentralized Parallel Modular UPS series
Transcription
UX SERIES - Decentralized Parallel Modular UPS series
The UX modular online UPS series, featured with DSP control, decentralized parallel structure, Modular N+X Parallel Redundancy, touch-screen LCD display, Hot swappable, programmable battery voltage, intelligent charge modes with settable charge current, Megatec/Modbus protocol, is an ideal solution to your PC, workstation, server, bank, industrial equipment, Internet data center, telecom, IT equipments or other mission-critical application, which is demanding for a thorough protection. Features http://www.upsonic.net Decentralized Parallel Structure with Hot-swappable feature Modular N+X Parallel Redundancy DSP-controlled Technology Unity Input Power Factor with Low Input Current Distortion & High Efficiency Fit into standard 19" Rack Frame Touch-screen LCD display for user's friendly operation High Power Density up to 200KVA per rack for space saving InvestasYouGrow Compact in size, only 3U height Superior MTBF and MTTR Emergency Power Off device can be operated on site or remotely Common Battery Programmable Battery Voltage Intelligent Charge Modes with smart charge current adjustment Megatec/Mod Bus protocol supported Powerful charger built in Modular and UPS frame Versatile communication interfaces provided for different applications Matching battery modular also available UX SERIES - Decentralized Parallel Modular UPS series UMX-50K / UMX-100K UTX-60K / UTX-100K / UTX-200K DSP-controlled Technology With advanced DSP control, the UX Series decentralized parallel modular series offers maximum power density in the UPS filed. UX Frame (200KVA) UX Decentralized Parallel Modular UPS Series UX Frame (60KVA) UMX-50K / UMX-100K UTX-60K / UTX-100K / UTX-200K Compact in size, only 3U height It is very compact and high-efficient comparing with current offers in the markets. Fit into standard 19" Rack Frame Using standard 19" Rack Frame, the UX Series 3U module with special rear configuraron may be easily fitted in. Modular N+X Parallel Redundancy Thanks for its N+X parallel redundancy technology used, the UX series may freely set the modules connected to N+X according to the protection level required by the equipment connected. Superior MTBF and MTTR Superior MTBF (Meantime before failure) and MTTR (Meantime to Repair) design minimizes service and maintenance costs and no skilled personnel on site is required, and only simply exchanges the module for an easy fault recovery. Decentralized Parallel Structure with Hot-swappable feature Decentralized parallel structure reduces the Single points of failure as well as minimizes service and maintenance costs. Unity Input Power Factor with Low Input Current Distortion & High Effíciency Thanks for DSP Control technology ¡mplemented, the UPS may reach Unity Power factor, low input currentTHD as well as high output efficiency. Emergency Power Off device can be operated on site or remotely Versatile communkation interfaces provided for different applications Besides RS232 interface for the module itself, the UPS can be monitored and controlled vía RS485, dry contact card or Ethernet (SNMP) card installed in the two intelligent slots. InvestasYouGrow Thanks for the ability of true modular UPS systems to easily scale power. It is possible to add power as the data center power requirements grow, which eliminates the high initial investment cost of purchasing power capacity that is not required at the first stage of investment. High Power Density up to 200KVA per rack for space saving With smallest footprint, the UX series reaches highest power density up to 200KVA per rack for space saving. Intelligent Charge Modes with smart charge current adjustment The UPS provides 3-mode charge methods, one is boost charge, another is equalized charge and the other is floating charge according to the status of the battery, enhance extends the life of the battery. Charge current can be adjusted according to battery capacity installed. Common Battery Common battery design enables several modules ¡n parallel to use one battery bank to save unnecessary extra wiring and investment to the batteries. Programmable Battery Voltage The battery voltage can be set from 192Vdc to 240Vdc for UMX series and from 384Vdc to 480Vdc for UTX series according to the demand of battery runtime. Powerful charger built in Modular and UPS frame Each module has a built-in powerful charger at 6A to escálate the total charge capacity up to máximum 60A. Megatec/Mod Bus protocol supported The complete UPS system can"talkto"computer system via its Megatec or Mod Bus protocol Touch-screen LCD display for user's friendly operation Optional control module with 5"touch-screen LCD display provides multilingual messages with fruitful UPS information on-screen or remotely. Matching battery modular alsoavailable UPX Decentralized Parallel Modular UPS UMX-50K Model Capacity (VA/W) UPS Frame 4~100KVA / 3.2 ~80KW 4KVA / 3.2KW - 6KVA / 4.8KW - 10KVA / 8KW UMX-Module Phase 3Phase/4Wires + Ground or 1Phase 2 Wires + Ground Rated Voltage 380/400Vac or 220/230VAC Voltage Range 208-478VAC or 120VAC-276VAC Frequency Range Input UMX-100K 4~50KVA / 3.2~40KW 40Hz-70Hz Power Factor ≥0.99 Current THDi ≤5% (100% nonlinear load) Max. voltage: +15% (optinal +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%) Bypass Voltage Range Frequency protection range: ±10% Generator Input Support Phase Single phase & Ground 220/230VAC Rated Voltage 0.8 Power Factor ±2% Voltage Regulation Output Frequency Utility Frame synchronized ton Mains, Inverter free run at 50/60±0.2Hz if out of set window (±1%, ±2%, ±4%, ±5%, ±10% settable) Battery Mode (50/60Hz±0.2) Hz 3:1 Crest Factor ≤2% with linear load ≤5% with non linear load THD Pure Sinewave Waveform Efficiency ≥90% at normal mode Voltage 192/216/240Vdc, battery quantity (optional) Battery 30A Max. (charge current can be set according to battery capacity installed) UPS Frame Charging Current UMX Module 6A Max. (charge current can be set according to battery capacity installed) Transfer Time Utility to Battery: 0ms; Utility to bypass: 0ms Overload AC Mode Load ≤110%: last 60min, ≤125%: last 1S, ≤150%: last 200ms, ≥150% shut down UPS immediately. Bat. Mode Load ≤110%: last 30S, ≤125%: last 1S, ≤150%: last 200ms, ≥150% shut down UPS immediately. Input Breaker (4KVA:32A / 6KVA:40A / 10KVA:60A) Bypass Mode Protection Short Circuit Hold Whole System Overheat Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately Battery Low Alarm and Switch off Self-diagnostics Upon Power On and Software Control Shut down UPS immediately EPO (optional) Battery Advanced Battery Management Noise Suppression Alarms Complies with EN62040-2 Audible & Visual Line Failure, Battery Low, Overload, System Fault Line Mode, Backup -mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault Status LED & LCD Display Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature Reading On the LCD Communication Interface RS232, RS485, Intelligent slot x 2, Dry Contact UPS Frame UPN Module RS232 Operating Temperature 0°C~40°C Storage Temperature Environment 60A Max. (charge current can be set according to battery capacity installed) -25°C~+55°C Humidity 0~95% non condensing Altitude <1500m Noise <50dB (at 1 meter) Safety Conformance CE - EN/IEC 62040-2, EN/IEC 62040-1-1 UMX Module Model Description Dimension (WxHxD) Net Weight (Kg) UMX-M04 4KVA 3/1 Module 443x131x580mm 3U 21.0 UMX-M06 6KVA 3/1 Module 443x131x580mm 3U 23.0 UMX-M10 10KVA 3/1 Module 443x131x580mm 3U 25.0 UMX-B07 for 18pcs 7AH bat. 443x131x580mm 3U 52.0 UMX-B09 for 18pcs 9AH bat. 443x131x580mm 3U 60.0 Dimension (WxHxD) mm Net Weight *Battery Module fo UPNX Series UMX UPS Frame Model Description Application UMX-20K 20KVA UPS Frame UMX-30K 30KVA UPS Frame for max. 5 x 6KVA Modules UMX-50K 50KVA UPS Frame for max. 5 x 10KVA Modules UMX-100K 40/60/100KVA UPS Frame for max. 10 x 4/6/10KVA Modules for max. 5 x 4KVA Modules 600x1400x840 138kgs 150kgs 600x2000x840 213kgs UPX Decentralized Parallel Modular UPS UTX-60K Model Capacity (VA/W) UPS Frame UTX-100K 10~60KVA/9~54KW UTX-Module 10KVA/9KW, 15KVA/13.5KW, 20KVA/18KW Phase Input 3 Phase 4 Wires and Ground Rated Voltage 380 / 400 /415 Vac Voltage Range 208~478Vac Frequency Range 40Hz-70Hz Power Factor ≥0.99 Current THDi ≤3% (100% nonlinear load) Max. voltage: +15% (optional +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%) Frequency protection range: ±10% Bypass Voltage Range Generator Input Support 3 Phase 4 Wires and Ground Phase 380/400/415Vac Rated Voltage 0.9 Power Factor ±2% Voltage Regulation Output Frequency Utility Frame ±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency (optional) Battery Mode 50/60±0.2%Hz 3:1 Crest Factor ≤2% with linear load ≤5% with non linear load THD Pure Sinewave Waveform Efficiency ≥92% at normal mode 384V / 408V / 432V / 456V / 480V DC; battery quantity (optional) Voltage Battery Charging Current 18A Max. (charge current can be set according to battery capacity installed) UPS Frame 30A Max. (charge current can be set according to battery capacity installed) Utility to Battery: 0ms; Utility to bypass: 0ms Overload AC Mode Load≤ 110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, ≥150%: shut down UPS Immediately Bat. Mode Load≤ 110%: last 10min, ≤125%: last 1min, ≤150%: last 1sec, ≥150%: shut down UPS Immediately Bypass Mode Breaker (10KVA: 20A / 15KVA: 32A / 20KVA:40A) Hold Whole System Short Circuit Overheat Line Mode: Switch to Bypass / Backup Mode: Shut down UPS immediately Alarm and Switch off Battery Low Self-diagnostics Upon Power On and Software Control EPO (optional) Shut down UPS immediately Battery Advanced Battery Management Complies with EN62040-2 Noise Suppression Alarms 60A Max. (charge current can be set according to battery capacity installed) 6A Max. (charge current can be set according to battery capcity installed) UTX Module Transfer Time Protection UTX-200K 10~200KVA/9~180KW 10~100KVA/9~90KW Line Failure, Battery Low, Overload, System Fault Audible & Visual Line Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault Status LED & LCD Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature Reading On the LCD Communication UPS Frame Interface RS232, RS485, Inteligent slot x2, Dry Contact 0°C~40°C Operating Temperature Storage Temperature Environment Humidity 0~95% non condensing Altitude < 1500m <60dB (at 1 meter) Noise Safety Conformance CE, EN/IEC 62040-2, EN/IEC 62040-1-1 UTX Module Model Dimension (WxHxD) Description Net Weight (Kg) UTX-M10 10KVA 3/3 Module 443x131x580mm 3U 26.0 UTX-M15 15KVA 3/3 Module 443x131x580mm 3U 30.0 UTX-M20 20KVA 3/3 Module 443x131x580mm 3U 31.0 UPNX UPS Frame Model UTX-60K UTX-100K UTX-200K Dimension (WxHxD) mm Net Weight 600x1400x840 145kgs for max. 5 x 10/15/20KVA Modules 600x1400x840 170kgs for max. 10 x 10/15/20KVA Modules 600x2000x840 230kgs Description 30/45/60KVA UPS Frame Application for max. (3+1) x 10/15/20KVA Modules 50/75/100KVA UPS Frame 100/150/200KVA UPS Frame *Specifications subject to change without prior notice. **Some systems may require isolation transformers for special voltages
Similar documents
UMX SERIES
equipments or other mission-critical application, which is demanding for a thorough protection.
More information