UMX SERIES
Transcription
UMX SERIES
6-50KVA MODULAR HOT SWAPPABLE POWER MODULES 5” TOUCH SCREEN LCD ISOLATION TRANSFORMER MODULAR HOT SWAPPABLE BATTERIES The UX modular online UPS series, featured with DSP control, decentralized parallel structure, Modular N+X Parallel Redundancy, touch-screen LCD display, Hot swappable, programmable battery voltage, intelligent charge modes with settable charge current, Megatec/Modbus protocol, is an ideal solution to your PC, workstation, server, bank, industrial equipment, Internet data center, telecom, IT equipments or other mission-critical application, which is demanding for a thorough protection. Features http://www.upsonic.net Decentralized Parallel Structure with Hot-swappable feature Modular N+X Parallel Redundancy DSP-controlled Technology Unity Input Power Factor with Low Input Current Distortion & High Efficiency Fit into standard 19" Rack Frame Touch-screen LCD display for user's friendly operation High Power Density up to 200KVA per rack for space saving InvestasYouGrow Compact in size, only 3U height Superior MTBF and MTTR Emergency Power Off device can be operated on site or remotely Common Battery Programmable Battery Voltage Intelligent Charge Modes with smart charge current adjustment Megatec/Mod Bus protocol supported Powerful charger built in Modular and UPS frame Versatile communication interfaces provided for different applications Matching battery modular also available UX SERIES - Decentralized Parallel Modular UPS series UMX 6-18K / UMX 10-30K / UMX 10-50K UTX 10-60K / UTX 10-100K / UTX 20-200K DSP-controlled Technology With advanced DSP control, the UX Series decentralized parallel modular series offers maximum power density in the UPS filed. UX Frame (60KVA) UX Decentralized Parallel Modular UPS Series UX Frame (200KVA) UMX-50K / UMX-100K UTX-60K / UTX-100K / UTX-200K Compact in size, only 3U height It is very compact and high-efficient comparing with current offers in the markets. Fit into standard 19" Rack Frame Using standard 19" Rack Frame, the UX Series 3U module with special rear configuraron may be easily fitted in. Modular N+X Parallel Redundancy Thanks for its N+X parallel redundancy technology used, the UX series may freely set the modules connected to N+X according to the protection level required by the equipment connected. Superior MTBF and MTTR Superior MTBF (Meantime before failure) and MTTR (Meantime to Repair) design minimizes service and maintenance costs and no skilled personnel on site is required, and only simply exchanges the module for an easy fault recovery. Decentralized Parallel Structure with Hot-swappable feature Decentralized parallel structure reduces the Single points of failure as well as minimizes service and maintenance costs. Unity Input Power Factor with Low Input Current Distortion & High Effíciency Thanks for DSP Control technology implemented, the UPS may reach Unity Power factor, low input currentTHD as well as high output efficiency. Emergency Power Off device can be operated on site or remotely Versatile communkation interfaces provided for different applications Besides RS232 interface for the module itself, the UPS can be monitored and controlled vía RS485, dry contact card or Ethernet (SNMP) card installed in the two intelligent slots. Invest As You Grow Thanks for the ability of true modular UPS systems to easily scale power. It is possible to add power as the data center power requirements grow, which eliminates the high initial investment cost of purchasing power capacity that is not required at the first stage of investment. High Power Density up to 200KVA per rack for space saving With smallest footprint, the UX series reaches highest power density up to 200KVA per rack for space saving. Intelligent Charge Modes with smart charge current adjustment The UPS provides 3-mode charge methods, one is boost charge, another is equalized charge and the other is floating charge according to the status of the battery, enhance extends the life of the battery. Charge current can be adjusted according to battery capacity installed. Common Battery Common battery design enables several modules in parallel to use one battery bank to save unnecessary extra wiring and investment to the batteries. Programmable Battery Voltage The battery voltage can be set from 192Vdc to 240Vdc for UMX series and from 384Vdc to 480Vdc for UTX series according to the demand of battery runtime. Powerful charger built in Modular and UPS frame Each module has a built-in powerful charger at 6A to escálate the total charge capacity up to máximum 60A. Megatec/Mod Bus protocol supported The complete UPS system can"talkto"computer system via its Megatec or Mod Bus protocol Touch-Screen LCD display for user's friendly operation Optional control module with 5" touch-screen LCD display provides multilingual messages with fruitful UPS information on-screen or remotely. Matching Battery Modular Available UX Series Decentralized Parallel Modular UPS Model Capacity (VA/W) UPS Frame UMX-20K UMX-30K UMX-50K UMX-100K 6~20KVA 6~30KVA 6~50KVA 10~100KVA 6KVA / 4.8KW (6KVA / 5.4KW*) - 10KVA / 8KW (10KVA / 9KW*) UMX-Module Phase Single Phase 2 Wires + Neutral + Ground Rated Voltage 208 / 220 / 230 / 240VAC Voltage Range 140VAC-276VAC Frequency Range Input 40Hz-70Hz Power Factor ≥0.99 Current THDi ≤5% (100% nonlinear load) Max. voltage: +15% (optinal +5%, +10%, +25%) Min. voltage: -45% (optional -20%, -30%) Bypass Voltage Range Frequency protection range: ±10% Support Generator Input Phase Single Phase 2 Wires + Neutral + Ground 120/240VAC (120/208 optional) Rated Voltage Galvanic Isolation Isolation Transformer Inside Cabinet (Standard) 0.8 (0.9 Optional*) Power Factor ±2% Voltage Regulation Output Frequency Utility Frame 50/60 Hz ±0.05% Battery Mode 50/60 Hz ±0.025% 3:1 Crest Factor <2% with linear load <3% with non linear load THD Pure Sinewave Waveform Efficiency ≥92% Online mode Voltage 192/216/240Vdc, battery quantity (optional) Battery 30A Max. (charge current can be set according to battery capacity installed) UPS Frame Charging Current UMX Module 6A Max. (charge current can be set according to battery capacity installed) Transfer Time Utility to Battery: 0ms; Utility to bypass: 0ms Overload AC Mode Load 110%: constantly, <110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, ≥150% to bypass immediately. Bat. Mode Load ≤110%: last 30S, ≤125%: last 1S, ≤150%: last 200ms, ≥150% shut down UPS immediately. Input Breaker (6KVA:40A / 10KVA:60A) Bypass Mode Protection Short Circuit Hold Whole System Overheat Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately Battery Low Alarm and Switch off Self-diagnostics Upon Power On and Software Control Shut down UPS immediately EPO (optional) Battery Advanced Battery Management Maintenance Bypass Alarms Standard - Internal Breaker (No Break) Audible & Visual Line Failure, Battery Low, Overload, System Fault Line Mode, Backup -mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault Status LED & LCD Display Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature Reading On the LCD Communication Interface RS232, RS485, Intelligent slot x 2, Dry Contact UPS Frame SNMP Includes SNMP Slot - Interfase (Optional) Operating Temperature 0°C~40°C Storage Temperature Environment -25°C~+55°C Humidity 0~95% non condensing Altitude 1500m (No Derate) Noise Safety Conformance 60A Max. (charge current can be set according to battery capacity installed) <55dB (at 1 meter) CE / FCC Part 15 / EN/IEC 62040-1-1 / EN/IEC 62040-2 / IEC 62040-2 C3 / IEC 62040-3 3C/EN60950/EN50091-1 / EN 61000 - 4.2.3.4.5.6.8.9.11 LEVEL III / IEC60664-1 LEVEL IV Industry Standard UMX Modules Model Description Dimension (WxHxD) Net Weight (Kg) UMX-M06 6KVA 3/1 Module 443x131x580mm 3U 23.0 UMX-M10 10KVA 3/1 Module 443x131x580mm 3U 25.0 UMX-B07 for 18pcs 7AH bat. 443x131x580mm 3U 52.0 UMX-B09 for 18pcs 9AH bat. 443x131x580mm 3U 60.0 Dimension (WxHxD) mm Net Weight UMX UPS Frames Model Description Application 20KVA UPS Frame for max. 5 x Modules UMX-30K 30KVA UPS Frame for max. 5 x Modules UMX-50K 50KVA UPS Frame for max. 5 x Modules UMX-100K 40/60/100KVA UPS Frame for max. 10 x Modules *Specifications subject to change without prior notice. **Some systems may require isolation transformers for special voltages 600x1600x840 138kgs 150kgs 600x2000x840 213kgs REV.09C.2014 UMX-20K
Similar documents
UX SERIES - Decentralized Parallel Modular UPS series
equipments or other mission-critical application, which is demanding for a thorough protection.
More information