BV Pulsera - InCenter
Transcription
BV Pulsera - InCenter
PHILIPS HEALTHCARE Product Recycling Passport Product name: Identification code Total weight (in Kg) Producer/ Manufacturer BV Pulsera 0718-095-001 510 kg (approximately; dependent on specific configuration) Name company: Address: Zip code: Country: Electronic info: Recycle Info Philips Medical Systems Veenpluis 6 5684 PC Best Netherlands http://www.healthcare.philips.com/us/about/sustainability/recycling/ Items: • Special attention • • • • • • Be aware of possibly contaminated system parts and materials! (biological hazard) For dismantling activities Treatment Facilities must consider the national requirements. For personnel that can come into contact with contaminated material, preventive measures pursuant to national requirements must be taken into account Removal of units / weights can cause the system to tilt! Removal of units / weights can cause unexpected movements of guidances! Release of brakes can cause unexpected movements of guidances! Brakes cannot prevent unexpected movements due to the removal of units /weights! High-voltage parts (e.g. capacitors) are marked with Before dismantling the vacuum II-Insert, drill a small hole to let air in the insert Vacuum glass tube of X-ray tank can implode! II-TV (page 4-10) Items: • X-ray tank (page 13) Location X-ray tank (page 13) Oil Type: Battery, 4x alkaline 1,5V [44 grams] (when option “remote control/viewpad” is present) CR2032 3.0V Lithium coin cell of 3 gram CR2032 3.0V Lithium coin cell of 3.2 gram (when option “Dell PC” is present) To be Removed Location System parts that were in the patient environment, and that were not disinfected Fluids / Gases Batteries Page 1 of 20 Pb - PbO - S.A.E. battery of 34,7 kg; containing lead (Pb), lead dioxide (PbO) and Sulfuric Acid Electrolyte (S.A.E.) Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Location (page 3) Electronics (page 15) (page 3) PHILIPS HEALTHCARE Product Recycling Passport Substances: Hazardous Lead (Pb) for X-ray shielding Lead (Pb) for soldering To be Removed Cadmium (Cd) + Beryllium Oxide (BeO) inside the II-Insert on the glass output window Mercury (Hg) in switch on printed circuit board for systems delivered before September 2006 Mercury (Hg) in LCD screens Page 2 of 20 Location II-TV (page 4-10) Grid (page 11) X-ray cover (page 12) X-ray tank (page 13) Collimator (page 14) Electronics (page 15) Display screens (page 16-20) II-TV (page 4-10) II-TV (page 4-10) LCD screens (page 16-20) Note: to facilitate recycling, all plastic parts weighing > 50 grams are marked according to ISO11469 & ISO1043. Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 PHILIPS HEALTHCARE Page 3 of 20 Product Recycling Passport Grid II-TV: page 4-10 Grid: page 11 X-ray cover: page 12 X-ray tank: page 13 Collimator: page 14 Electronics: page 15 Display screens: page 16-20 Collimator (inside) II-TV X-ray tank X-ray cover Electronics (inside) Detail battery (inside) Optional remote control /viewpad; when present: Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Display screens PHILIPS HEALTHCARE Product Recycling Passport Page 4 of 20 9” II-TV: Recycle Info Special attention Items: Location Before dismantling the vacuum II-Insert, drill a small hole to let air in the insert Hazardous Substances: To be Removed Lead (Pb) Cadmium (Cd) + Beryllium Oxide (BeO) inside the II-Insert on the glass output window Mercury (Hg) in switch on printed circuit board for systems delivered before September 2006 Before September 2006: 4 See detail B Printed circuit board 1 1 2 See detail A Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Location 1, page 4-5 2, page 4-5 4, page 4-5 + 7 PHILIPS HEALTHCARE Product Recycling Passport Before September 2006: 4 See detail B Printed circuit board 1 1 2 Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Page 5 of 20 PHILIPS HEALTHCARE Product Recycling Passport 2 1 Detail A Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Page 6 of 20 PHILIPS HEALTHCARE Product Recycling Passport Page 7 of 20 Before September 2006: component contains mercury 4 Detail B printed circuit board 4522 167 02681 up and including 4522 167 02687 Before September 2006: 4 Detail B printed circuit board 4522 167 02431 up and including 4522 167 02439 Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 PHILIPS HEALTHCARE Product Recycling Passport Page 8 of 20 12” II-TV: Recycle Info Special attention Items: Location Before dismantling the vacuum II-Insert, drill a small hole to let air in the insert Hazardous Substances: To be Removed Lead (Pb) Cadmium (Cd) + Beryllium Oxide (BeO) inside the II-Insert on the glass output window Mercury (Hg) in switch on printed circuit board for systems delivered before September 2006 Before September 2006: Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Location 1, page 8-9 2, page 8-9 4, page 8 + 10 PHILIPS HEALTHCARE Product Recycling Passport Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Page 9 of 20 PHILIPS HEALTHCARE Product Recycling Passport Before September 2006: Before September 2006: Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Page 10 of 20 PHILIPS HEALTHCARE Product Recycling Passport Page 11 of 20 Grid: Hazardous Substances: Lead (Pb 99,5%) To be Removed Example larger and smaller grid (only 1 present in system) Cross-section of grid: Paper Interspace Material Location Enclosed between cover plates Lead Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 PHILIPS HEALTHCARE Product Recycling Passport Page 12 of 20 X-ray cover: Hazardous Substances: Lead (Pb 99,5%) To be Removed Lead (Pb) Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Location Glued at inside; see photo below PHILIPS HEALTHCARE Page 13 of 20 Product Recycling Passport X-ray tank: Vacuum glass tube can implode! Lead (Pb) Detail of X-ray tank X-section of X-ray tank Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Oil PHILIPS HEALTHCARE Product Recycling Passport Page 14 of 20 Collimator: Hazardous Substances: Lead (Pb 99,5%); 0,42 kg To be Removed Lead (Pb) Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Location Ring of lead, lead on shutters and wedges; See photo below. PHILIPS HEALTHCARE Product Recycling Passport Page 15 of 20 Electronics: Batteries To be Removed Hazardous Type: 1x CR2032, 3.0 Volt, 3.0 gram LiMnO2 CR2032 3.0V Lithium coin cell of 3.2 gram (when option “Dell PersonalComputer” [Philips-indication: Viewforum hardware] is present) Substances: Lead (Pb) is present in the soldering of some PCBs To be Removed Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Location See picture below In Dell PC when present Location PCBs (PrintedCircuitBoards) PHILIPS HEALTHCARE Page 16 of 20 Product Recycling Passport Display screens: FOLLOWING PAGES PROVIDE INFORMATION ON VARIOUS SCREENS POSSIBLY PRESENT IN THE SYSTEM. LCD screen FIMI MCL180-L / 9919-320-5089x | PAGE 1 of 2 Hazardous Substances: Type Cd Hg To be Removed Pb Cr6+ PBB PBDE Location Quantity 0 21 mg max. (*) Lead is present in the soldering process of PCBs 0 0 0 (*) Mercury is present in Backlight lamps: 3.5mg x 6 lamps Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Next figure (1) Next figure (2.x) PHILIPS HEALTHCARE Product Recycling Passport LCD screen FIMI MCL180-L / 9919-320-5089x | PAGE 2 of 2 Fe Al Cu Plastics Boards (S2 > 10cm2) CD 6.0 kg 0 0.1 kg 1.5 kg 96 cm2 / 260 g 320 cm2 / 230 g 144 cm2 / 66 g 72 cm2 / 54 g 3 kg Material (3.4 kg in the pedestal) Cables (0.4 kg in the pedestal) S.M.P.S. (item 2.1 in the picture) Logic Board (item 2.2 in the picture) Inverter (item 2.3 in the picture) LCD Driver (item 2.4 in the picture) 18” Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Page 17 of 20 PHILIPS HEALTHCARE Page 18 of 20 Product Recycling Passport LCD screen FIMI MCL180-HB / 9919-320-5088x Hazardous Substances: Type Cd Hg To be Removed Pb Cr6+ PBB PBDE Location Quantity 0 36 mg max. (*) Lead is present in the soldering process of PCBs 0 0 0 (*) Mercury is present in Backlight lamps: 3mg x 12 lamps Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Figure below (1) Figure below (2.x) PHILIPS HEALTHCARE Product Recycling Passport Page 19 of 20 LCD screen FIMI MCL180-LT / 9919-320-5092x Hazardous Substances: Type To be Removed Location Quantity Cd 0 Hg 21mg max. (*) Pb Lead is present in the soldering process of PCBs Cr6+ 0 PBB 0 PBDE 0 (*) Mercury is present in Backlight lamps: 3.5mg x 6 lamps Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Next figure (1) Next figure (2.x) PHILIPS HEALTHCARE Product Recycling Passport Page 20 of 20 LCD screen FIMI MCL180-HBT / 9919-320-5091x Hazardous Substances: Type Cd Hg Pb To be Removed Location Quantity 0 36 mg max. (*) Lead is present in the soldering process of PCBs Cr6+ 0 PBB 0 PBDE 0 (*) Mercury is present in Backlight lamps: 3 mg x 12 lamps Title: Recycling passport BV Pulsera 0718-095-001 DocID: XDR054-090781 Next figure (1) Next figure (2.x)