BV Pulsera - InCenter

Transcription

BV Pulsera - InCenter
PHILIPS
HEALTHCARE
Product Recycling Passport
Product name:
Identification code
Total weight (in Kg)
Producer/
Manufacturer
BV Pulsera
0718-095-001
510 kg (approximately; dependent on specific configuration)
Name company:
Address:
Zip code:
Country:
Electronic info:
Recycle Info
Philips Medical Systems
Veenpluis 6
5684 PC Best
Netherlands
http://www.healthcare.philips.com/us/about/sustainability/recycling/
Items:
•
Special attention
•
•
•
•
•
•
Be aware of possibly contaminated system parts and
materials! (biological hazard)
For dismantling activities Treatment Facilities must
consider the national requirements.
For personnel that can come into contact with
contaminated material, preventive measures pursuant to
national requirements must be taken into account
Removal of units / weights can cause the system to tilt!
Removal of units / weights can cause unexpected
movements of guidances!
Release of brakes can cause unexpected movements of
guidances! Brakes cannot prevent unexpected movements
due to the removal of units /weights!
High-voltage parts (e.g. capacitors) are
marked with
Before dismantling the vacuum II-Insert, drill a small hole
to let air in the insert
Vacuum glass tube of X-ray tank can implode!
II-TV (page 4-10)
Items:
•
X-ray tank (page 13)
Location
X-ray tank (page 13)
Oil
Type:
Battery, 4x alkaline 1,5V [44 grams] (when option “remote
control/viewpad” is present)
CR2032 3.0V Lithium coin cell of 3 gram
CR2032 3.0V Lithium coin cell of 3.2 gram (when option “Dell
PC” is present)
To be Removed
Location
System parts that
were in the patient
environment, and that
were not disinfected
Fluids / Gases
Batteries
Page 1 of 20
Pb - PbO - S.A.E. battery of 34,7 kg; containing lead (Pb), lead dioxide
(PbO) and Sulfuric Acid Electrolyte (S.A.E.)
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Location
(page 3)
Electronics (page 15)
(page 3)
PHILIPS
HEALTHCARE
Product Recycling Passport
Substances:
Hazardous
Lead (Pb) for X-ray shielding
Lead (Pb) for soldering
To be Removed
Cadmium (Cd) + Beryllium Oxide (BeO) inside the II-Insert on the
glass output window
Mercury (Hg) in switch on printed circuit board for systems
delivered before September 2006
Mercury (Hg) in LCD screens
Page 2 of 20
Location
II-TV (page 4-10)
Grid (page 11)
X-ray cover (page 12)
X-ray tank (page 13)
Collimator (page 14)
Electronics (page 15)
Display screens (page
16-20)
II-TV (page 4-10)
II-TV (page 4-10)
LCD screens (page
16-20)
Note: to facilitate recycling, all plastic parts weighing > 50 grams are marked according to ISO11469
& ISO1043.
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
PHILIPS
HEALTHCARE
Page 3 of 20
Product Recycling Passport
Grid
II-TV: page 4-10
Grid: page 11
X-ray cover: page 12
X-ray tank: page 13
Collimator: page 14
Electronics: page 15
Display screens: page 16-20
Collimator (inside)
II-TV
X-ray tank
X-ray cover
Electronics (inside)
Detail battery (inside)
Optional remote control
/viewpad; when present:
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Display screens
PHILIPS
HEALTHCARE
Product Recycling Passport
Page 4 of 20
9” II-TV:
Recycle Info
Special attention
Items:
Location
Before dismantling the vacuum II-Insert, drill a small hole to let air
in the insert
Hazardous
Substances:
To be Removed
Lead (Pb)
Cadmium (Cd) + Beryllium Oxide (BeO) inside the II-Insert on the glass
output window
Mercury (Hg) in switch on printed circuit board for systems delivered
before September 2006
Before September 2006:
4
See detail B
Printed circuit board
1
1
2
See detail A
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Location
1, page 4-5
2, page 4-5
4, page 4-5 + 7
PHILIPS
HEALTHCARE
Product Recycling Passport
Before September 2006:
4
See detail B
Printed circuit board
1
1
2
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Page 5 of 20
PHILIPS
HEALTHCARE
Product Recycling Passport
2
1
Detail A
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Page 6 of 20
PHILIPS
HEALTHCARE
Product Recycling Passport
Page 7 of 20
Before September 2006:
component contains mercury
4
Detail B printed circuit board 4522 167 02681 up and including 4522 167 02687
Before September 2006:
4
Detail B printed circuit board 4522 167 02431 up and including 4522 167 02439
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
PHILIPS
HEALTHCARE
Product Recycling Passport
Page 8 of 20
12” II-TV:
Recycle Info
Special attention
Items:
Location
Before dismantling the vacuum II-Insert, drill a small hole to let air
in the insert
Hazardous
Substances:
To be Removed
Lead (Pb)
Cadmium (Cd) + Beryllium Oxide (BeO) inside the II-Insert on the glass
output window
Mercury (Hg) in switch on printed circuit board for systems delivered
before September 2006
Before September 2006:
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Location
1, page 8-9
2, page 8-9
4, page 8 + 10
PHILIPS
HEALTHCARE
Product Recycling Passport
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Page 9 of 20
PHILIPS
HEALTHCARE
Product Recycling Passport
Before September 2006:
Before September 2006:
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Page 10 of 20
PHILIPS
HEALTHCARE
Product Recycling Passport
Page 11 of 20
Grid:
Hazardous
Substances:
Lead (Pb 99,5%)
To be Removed
Example larger and smaller
grid (only 1 present in system)
Cross-section of grid:
Paper
Interspace
Material
Location
Enclosed between
cover plates
Lead
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
PHILIPS
HEALTHCARE
Product Recycling Passport
Page 12 of 20
X-ray cover:
Hazardous
Substances:
Lead (Pb 99,5%)
To be Removed
Lead (Pb)
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Location
Glued at inside; see
photo below
PHILIPS
HEALTHCARE
Page 13 of 20
Product Recycling Passport
X-ray tank:
Vacuum glass tube can implode!
Lead (Pb)
Detail of X-ray tank
X-section of X-ray tank
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Oil
PHILIPS
HEALTHCARE
Product Recycling Passport
Page 14 of 20
Collimator:
Hazardous
Substances:
Lead (Pb 99,5%); 0,42 kg
To be Removed
Lead (Pb)
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Location
Ring of lead, lead on
shutters and wedges;
See photo below.
PHILIPS
HEALTHCARE
Product Recycling Passport
Page 15 of 20
Electronics:
Batteries
To be Removed
Hazardous
Type:
1x CR2032, 3.0 Volt, 3.0 gram LiMnO2
CR2032 3.0V Lithium coin cell of 3.2 gram (when option
“Dell PersonalComputer” [Philips-indication: Viewforum
hardware] is present)
Substances:
Lead (Pb) is present in the soldering of some PCBs
To be Removed
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Location
See picture below
In Dell PC when
present
Location
PCBs
(PrintedCircuitBoards)
PHILIPS
HEALTHCARE
Page 16 of 20
Product Recycling Passport
Display screens:
FOLLOWING PAGES PROVIDE INFORMATION ON VARIOUS SCREENS POSSIBLY
PRESENT IN THE SYSTEM.
LCD screen FIMI MCL180-L / 9919-320-5089x | PAGE 1 of 2
Hazardous
Substances:
Type
Cd
Hg
To be Removed Pb
Cr6+
PBB
PBDE
Location
Quantity
0
21 mg max. (*)
Lead is present in the
soldering process of
PCBs
0
0
0
(*) Mercury is present in Backlight lamps: 3.5mg x 6 lamps
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Next figure (1)
Next figure (2.x)
PHILIPS
HEALTHCARE
Product Recycling Passport
LCD screen FIMI MCL180-L / 9919-320-5089x | PAGE 2 of 2
Fe
Al
Cu
Plastics
Boards (S2 > 10cm2)
CD
6.0 kg
0
0.1 kg
1.5 kg
96 cm2 / 260 g
320 cm2 / 230 g
144 cm2 / 66 g
72 cm2 / 54 g
3 kg
Material
(3.4 kg in the pedestal)
Cables
(0.4 kg in the pedestal)
S.M.P.S. (item 2.1 in the picture)
Logic Board (item 2.2 in the picture)
Inverter (item 2.3 in the picture)
LCD Driver (item 2.4 in the picture)
18”
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Page 17 of 20
PHILIPS
HEALTHCARE
Page 18 of 20
Product Recycling Passport
LCD screen FIMI MCL180-HB / 9919-320-5088x
Hazardous
Substances:
Type
Cd
Hg
To be Removed Pb
Cr6+
PBB
PBDE
Location
Quantity
0
36 mg max. (*)
Lead is present in the
soldering process of
PCBs
0
0
0
(*) Mercury is present in Backlight lamps: 3mg x 12 lamps
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Figure below (1)
Figure below (2.x)
PHILIPS
HEALTHCARE
Product Recycling Passport
Page 19 of 20
LCD screen FIMI MCL180-LT / 9919-320-5092x
Hazardous
Substances:
Type
To be Removed
Location
Quantity
Cd
0
Hg
21mg max. (*)
Pb
Lead is present in the soldering process of PCBs
Cr6+
0
PBB
0
PBDE
0
(*) Mercury is present in Backlight lamps: 3.5mg x 6 lamps
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Next figure (1)
Next figure (2.x)
PHILIPS
HEALTHCARE
Product Recycling Passport
Page 20 of 20
LCD screen FIMI MCL180-HBT / 9919-320-5091x
Hazardous
Substances:
Type
Cd
Hg
Pb
To be Removed
Location
Quantity
0
36 mg max. (*)
Lead is present in the
soldering process of PCBs
Cr6+
0
PBB
0
PBDE
0
(*) Mercury is present in Backlight lamps: 3 mg x 12 lamps
Title: Recycling passport BV Pulsera 0718-095-001
DocID: XDR054-090781
Next figure (1)
Next figure (2.x)