24389-01A SE `02 spreads
Transcription
24389-01A SE `02 spreads
24389-01A Come in from the sun Welcome to a new generation of tanning products. While the concept of ‘sunless tanning’ lotions is not a new one, technology has finally caught up. The Sunless Express™ Spray Spa is the culmination of countless hours of research on methods of applying sunless tanning lotion. Sunless tanning products work by creating a response with the top two layers of your skin. Dihydroxyacetone, or DHA, reacts naturally with the protein in your skin. A brown “tan” forms within approximately two to three hours after your session, and continues to darken for up to 24 hours. The result is a substantive tan. It is absolutely water-resistant and diminishes only as the dead cells of the skin flake off - usually one to two weeks. DHA is a common chemical used in multiple ways throughout our normal everyday lives. For example, DHA is often used as an additive in food and cosmetics. Please take the time to read through this guide to familiarize yourself with the concept of sunless tanning and the proper usage of your new equipment. Thank you, and Welcome once again! 24389-01A i Introduction - contents Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii Get to Know the Sunless Express™ . . . . . . . . . . . . . . . . . . .1 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Before you tan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 During the tan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Safety features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 After the tan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Advanced controls . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Setting the clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Cleaning after use . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Before you turn out the lights . . . . . . . . . . . . . . . . . . .10 Changing/refilling solutions . . . . . . . . . . . . . . . . . . . . .11 Thorough periodic cleaning . . . . . . . . . . . . . . . . . . . .11 Mechanical inspection . . . . . . . . . . . . . . . . . . . . . . . .12 Component maintenance . . . . . . . . . . . . . . . . . . . . . .12 Remote Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Warranty information . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 24389-01A Technical Information . . . . . . . . . . . . . . . . . . . . .back cover ii Safety Information DANGER Shock hazard. Disconnect power before servicing. If the supply cord is damaged, it must be replaced by a special cord available from the manufacturer or its service agent. WARNING This product does not contain a sunscreen and does not protect against sunburn. Repeated exposure of unprotected skin while tanning may increase the risk of skin aging, skin cancer, and other harmful effects to the skin even if you do not burn. Avoid spraying directly into eyes. IMPORTANT CAUTION Read and follow all instructions regarding use and operation of the Sunless Express. Press the Stop button at any time to stop operations immediately. 88465 iii 24389-01A This product is in compliance with applicable requirements of UL 60335-1, IEC 335-2-23, and CAN/CSA-E335-1/3E-94. Safety Information DANGER Risque de chocs électriques. Débrancher l’alimentation électrique avant de procéder à la réparation ou à l’entretien de l’appareil. Un cordon d’alimentation endommagé doit être remplacé par un cordon particulier pouvant être acheté du fabricant ou d’un technicien. AVERTISSEMENT Ce produit ne contient pas d’écran solaire et ne protège pas contre les coups de soleil. L’exposition répétée d’une peau non protégée aux rayons ultraviolets peut accroître les risques de vieillissement et de cancer cutané et produirent d’autres effets nocifs même en l’absence de coups de soleil. Éviter de pulvériser le produit dans les yeux. IMPORTANT MISE EN GARDE Lire et suivre toutes les directives d’utilisation et de fonctionnement du spa Sunless Express. Pour que l’appareil cesse immédiatement de fonctionner, appuyer en tout temps sur le bouton Stop (Arrêt). 24389-01A Ce produit est conforme aux normes de rendement dans le documents UL 60335-1 , IEC 335-2-23 , CAN/CSA-E335-1/3E-94. 88465 iv Getting to Know the Sunless Express™ (The tanning area) SPEAKER WASHDOWN NOZZLE GANTRY SPRAY NOZZLE SPRAY MANIFOLD 24389-01A 1 Getting to Know... (Lower section of Control Cabinet) WATER HEATER AIR PUMP PUMPS (see next page) DISINFECTANT 24389-01A TANNING LOTION 2 Getting to Know... WASHDOWN SOLENOID EVACUATION FAN (at top of cabinet) PERISTALTIC PUMP EVACUATION PUMP 24389-01A 3 Getting to Know... (Control Module) RS-232 PORT (not currently used) T-MAX LINK CONTROL PORT REMOTE PORTS (not currently used) LIGHTS WASHDOWN CONTROL PAD 24389-01A MASTER POWER 4 Operation Operation of the sunless tanning booth requires just two buttons. The first is the “Start/Stop” button on the Sunless Express™ Remote Control (SERC) supplied with the booth (see illustration 1). Pressing this button sends a signal to the booth to allow a single session to run. After the session is complete the display on the SERC will indicate a “..” meaning the room needs to be sanitized. After cleaning the unit press the up (▲) button on the SERC until a “0” appears. Illustration 1 (SERC) Once the “Start/Stop” button (on the SERC) is pressed the booth receives the signal and is ready for the session. Enter the booth, close the door and an automated voice will explain the sunless tanning experience. Press the green “Start” button on the wall to begin (see illustration 2). The SERC is also capable of telling the booth to run two back-to-back sessions without resetting. To do this, press the up (▲) button until the display shows a “4” (signifying the Spray Manifold will make four passes over your body). Read on for tanning instructions as well as a complete script of the tanning session. Refer to Remote Connections - Operation with remote for operation while connected to a T-Max® remote system. 5 24389-01A Illustration 2 Operation - the tanning session Before you tan During the tanning session For best results, exfoliate before using the Upon closing the door you will hear the tanning unit. following instructions... Do not use lotion on your body before you tan. This may act as a barrier and prevent some areas from getting tan. “Welcome to the Sunless Express™ spray spa! For best results, follow the instructions exactly. Please place your feet in the boxes and stand as close to the door as possible. Point your toes toward the sides. Place your arms above your head and bend elbows slightly. Palms should be facing forward. Raise your chin upward. To hear the instructions again open the door and close it one time. Press the green start button to begin your session and again, place your hands above your head, palms facing forward.” Remove any makeup from face. Remove contacts. Remove all jewelry. Women: Place the shower cap right at the hairline. This will prevent any unnecessary tan lines on your forehead. Men: If you have a receding hair-line or balding - to prevent tan-line, do not wear the shower cap unless your hair is naturally very light or is chemically lightened. See the chart located on the rear wall of Apply neutralizing lotion to hands and the booth for complete positioning toes with special attention to cuticle cov- instructions. Pressing the “Start” button erage. Be careful not to apply neutraliz- will begin the tanning session. ing lotion to areas you want tan as white “At the end of the countdown, close spots will result. You may remove any your eyes and hold your breath as the misplaced blocker with a moisture wipe. spray passes your upper body. 3,2,1.” 24389-01A The spray mist will coat the front of your body. 6 Operation - the tanning session Safety features “You may open your eyes and breathe freely. Please turn around and face the door. Please place your feet in the boxes and stand as close to the door as possible. Point your toes toward the sides. Place your arms above your head and bend elbows slightly. Palms should be facing the door. Press the green start button to begin your session and again, place your hands above your head, palms facing the door.” Panic Stop Button - Pressing the “Stop” button will immediately end the session at any time. Gantry Safety Mechanism - If there is any pressure placed on the spray manifold during operation, the unit will stop and the session will end. Check the mechanism for any obstructions before using again. After the tan 7 24389-01A After your session, you will notice a light “At the end of the countdown, close mist on your body. First, wipe your hands your eyes and hold your breath as the with the moisture wipes. Next, gently spray passes your upper body. 3,2,1” wipe the rest of your body, as if getting The spray will now coat the back side of out of the shower. When you are completely dry, wipe your hands again with your body. the moisture wipes in case your hands “Thank you for using the Sunless came in contact with the solution while Express™ spray spa. At this time you drying off. Be sure you are completely dry may open your eyes and breathe before getting dressed. This will eliminate freely. Upon exiting the spa, please most of the bronzer residue on the inside dry off with the towels provided. of your clothing. Enjoy your tan.” You will not notice a lot of immediate color from your session. The tan will begin to develop within 2 to 3 hours after the session and continue to darken for up to 24 hours. Wait 4-6 hours before showering or engaging in activities which encourage persperation as this will wash the bronzer off your body before it has enough time to affect the color of your skin. Operation - advanced controls The Control Pad, located on the Control Module, offers additional controls for the salon owner. The illustration at right shows the “Home” screen, with the time and a scrolling message. After making adjustments, waiting 10 seconds will return the screen to “Home”. Execute [☞] - press to enter modes and select options Up [▲] - scrolls options upward Down [▼] - scrolls options downward Cycle Count Status Home [☞] [☞] [▲] Tanning [▼] [▲] [▼] [☞] Booth [☞] Displays number of complete sessions performed [▲] Door Status (open/closed) [▼] Light Status (on/off) Software Vers [☞] Displays software version number Sound Version [☞] Displays voice version number Tanning Cycle [☞] Starts a tanning cycle. Press [☞] again to finish the cycle Washdown Cycle[☞] Starts a washdown cycle Controls [☞] 24389-01A [▲] [▼] Settings [☞] [▲] [▼] Panic [☞] Interrupts the tanning session Booth Lights [☞] Turns lights on and off Clock [☞] Set time (see next page) [☞] [▲]/[▼] to adjust volume [☞] Resets position of spray manifold [▲] [▼] Volume Calibrate 8 Operation - advanced controls Setting the clock From the “Home” screen, press Execute [☞] to enter the option mode. Scroll through the three options using the Up [▲] or Down [▼] buttons, until you reach the Settings option. Press [☞] again to Home [☞] enter the Settings menu. Scroll to the Clock option and press [☞]. The hours digit on the time will blink. Press [▲] or [▼] until the desired hour is displayed. Press [☞]. The minutes blink. Set the minutes and press [☞] and then [▲] or [▼] to set am or pm. Wait a few seconds or press [☞] one more time to exit the setting mode. [▲] [▼] Settings [☞] [▲] [▼] Clock [☞] Hours blink [▲]/[▼] to adjust hours. [☞] to set Minutes blink [▲]/[▼] to adjust minutes. [☞] to set am or pm blinks [▲]/[▼] to select. 9 24389-01A [☞] to set Care and Maintenance Your Sunless Express™ spray spa has been Cleaning after use designed and engineered for years of serv- After each use it is necessary to clean and ice. However, much like changing the oil disinfect the booth by activating the in your car, there are some care and main- Washdown cycle. tenance issues to keep in mind. The next 1. Close the door and press the few pages outline the various periodic Washdown button on the Control duties you need to perform broken down Module located in the Control by frequency. Refer to the pictures in Cabinet. Getting to Know the Sunless Express™. 2. After the Washdown cycle is complete, wipe the internal walls. You may use the squeegee provided or a soft towel. WARNING 3. Disinfect and dry the step and door Shock hazard. handles. Disconnect power before servicing. 4. Reset the remote control unit by holding the up button until the display reads “0”. Before you turn out the lights At the end of each day of usage there are a few things to check to make sure the unit continues to function satisfactorily. 24389-01A 1. Stand the inside mat up on edge to allow it to dry and encourage air movement within the base cavity. 2. Be sure to leave the door open. 3. Check the level of tanning and disinfectant solution. Try not to let the levels drop below about 1 1/2 inches to avoid running dry. 10 Care and Maintenance Thorough periodic cleaning Changing/refilling solutions On a monthly basis a little extra care is For best results, the level of tanning soluneeded. tion and disinfectant should not be less 1. Thoroughly clean the internal walls, than 1 1/2 inches. When changing solurubber seals and spray manifold to tions you may pour any remaining liquid from the used bottle into the new one if remove any solution residue. there is enough room in the new bottle. 2. Remove the Floor Mat and Floor Mat 1. Lift the tanning solution and/or disinPlate and use a hose to spray them fectant container out of the Spill Tray off. and place on the floor. 3. Clean the outside of the unit as 2. Remove the cap, complete with the needed using non-ammonia cleanhose, from the used container. ers. 3. Remove the cap from the replace4. Replace the solution bottle with one ment container and screw onto the containing only water and run the used container to save any unused unit for a complete cycle to purge solution. the system. 4. Insert the solution filter hose into the 5. While the solution bottle is removed, new container and secure the cap. rinse the solution filters in warm water. 5. Place new bottle into Spill Tray. 6. Check to verify the solution filter hose touches the bottom of the container. 24389-01A 11 Care and Maintenance 24389-01A Mechanical inspection Along with the monthly thorough cleaning, inspect the unit’s mechanical integrity. 1. Inspect all bolts, nuts, screws and other fasteners to make sure all are secure. 2. Check door hinges for signs of wear. 3. Pay special attention to the Spray Manifold track system and belt for signs of wear. This is the heart of the unit. 4. Inspect the counterweight for smooth movement by sliding it up and down its guide. It should glide freely. 5. Check all hose connections, pumps, valves and water heater for leaks. 6. Make sure the AC power cord is in good shape and firmly plugged in at both ends. 7. Check all filters and clean or replace those which appear dirty. 8. Check proper operation of the gantry safety system... With the solution system off, turn unit on. Press down on the Spray Manifold as it rises. It should stop without much force. 9. Clean the spray nozzles carefully. 12 Component maintenance 1. Purge the water heater per manufacturers requirements. 2. Maintain Waster pump per manufacturers requirements. 3. The Evacuation Fan needs no regular maintenance. 4. Clean unit as described in Thorough periodic cleaning. Remote Connections T-Max® Products Your Sunless Express™ remote control unit incorporates advanced circuitry allowing it to connect and communicate with the popular T-Max® remote control systems. The booth can be connected to any T-Max Manager or 1A or 3A. Refer to the appropriate section that follows. T-Max® Manager Remote System This system is ideal for multiple sunbed installations, including the Sunless Express™. Simply connect the RJ-22 modular cable(s), described in the T-Max® Manager manual, into the remote port(s) located on the back of the Sunless Express™ Remote Control (SERC) and follow the instructions that came with your remote system. If you have an older TMax® Manager that does not support auto addressing, set the address of the SERC manually as described in Setting the address manually. You can place your booth at any location in the series (see illustration below). T-Max® 1A and 3A Remote Systems The T-Max® 1A and 3A can offer the same control as the T-Max® Manager in single unit installations. If you’re using a 1A, it must have a chip labelled “master” installed on its circuit board. After you have set the T-Max® 1A’s, or 3A’s, address to “0” (refer to your T-Max® user’s guide) and the SERC’s address to “1”, simply connect the RJ-22 modular cables, described in the T-Max® user’s guide, directly into either port located on the back of the SERC and either port on the back of the T-Max® 1A or 3A. Setting the address manually Before connecting the SERC to the TMax® Manager or T-Max® 1A or 3A, the address must first be set. Set the address manually as described below. 1. Remove power from the T-Max® Manager or 1A or 3A. 2. Plug in the SERC. It should show “9.9” on the display and sound an alarm. If it just shows “0” go to step 4. 13 24389-01A 3. Press and release the Start/Stop button. The display will flash “8.8” and the alarm will stop. Press the Up button until the display stops flashing and shows a “0”. Section - subheading 4. Press and hold the Start/Stop and Up buttons simultaneously until a “.1” appears. This may take about 5-6 seconds. Release the buttons. 5. Press the Start/Stop button. A flashing number will appear. This is the address that the SERC is set to. 6. Press the Up or Down button until the desired address is displayed. Note: When setting the addresses, remember these three rules; • Each tanning unit in the salon (including the SERC) needs a unique address. • Do not set the SERC to “00”. • If the period is flashing, you are over address 100. 7. Once the desired address is displayed, press and release the Start/Stop button. A steady “.1” will be displayed. 24389-01A 8. Press and hold both the Up and Down buttons until a “0” is displayed. Operation with remote When connected to a T-Max® system the unit operates differently than explained in Operation. The session is activated from the Manager, 1A or 3A. To activate a single session send a 2 from the remote (refer to your T-Max® manual). For a double session, send a four (4). This will activate the unit and the session starts when the tanner enters the booth and presses the Start button inside the unit. The use of two and four correspond to the number of passes the Spray Manifold will make over your body during the session. 9. Connect the SERC into the remote After the session is complete the SERC will display “..” indicating the room needs series. cleaning. Refer to Care and Maintenance - Cleaning after use for cleaning instructions. After cleaning, press the Up button on the SERC to clear the “..” indication and ready the unit for the next session. 14 Notes 24389-01A 15 Troubleshooting Problem Solution Overhead lights not working 1. Check power supply to unit 2. Check light power cord to control module 3. Press lights button on control module 4. Replace light(s) Unit will not start session once the 1. Is the SERC displaying a flashing decimal after the 0? If not, press the “Start/Stop” button green button is on 2. Check supply cord to switch Unit stops in mid session 1. Check gantry/belt for interference 2. Check counterweight for interference 3. Check gantry/belt for clip disconnection 4. Manifold may have tripped the safety switch 24389-01A Manifold is not moving during session 1. Check gantry/belt for interference 2. Check counterweight for interference 3. Check gantry/belt for clip disconnection 4. Manifold may have tripped the safety switch - Safety signal will be voiced Unit will not work with T-Max® 1. Check all connections 2. Make sure each unit has a unique address 3. Has the T-Max® Manager been disconnected 4. Has the T-Max® system been set-up correctly Solution is not coming through nozzles , air only 1. Check solution level 2. Check peristaltic pump for proper action 3. Check solution hoses and connections for leaks or disconnection 16 Troubleshooting Problem Solution Air is not coming through nozzles, 1. Check air hoses for disconnection 2. Check air pump for proper function solution only Manifold making loud pounding Unit has not made contact with limit switch or bottom of cycle. Adjust switch. noise at the top Nothing comes on 1. Check main power and connection 2. Check GFCI 3. Check control Module fuse Footwash feels cold 1. Check heater setting 2. Check power cord connection Footwash not working Check solenoid and or harness connection Washdown not working Check solenoid and or harness connection Users are consistently darker on one Check nozzles for clogs side The unit is overly foggy during session 1. Check ventilation fan power supply 2. Check duct connections 3. Replace ceiling filter 24389-01A 17 Warranty Sunless Express™ LIMITED LIFETIME WARRANTY The manufacturer of your Sunless Express™ spray unit warrants your spray unit to be free of structural defects in its material and workmanship, under normal use, for its lifetime. The manufacturer will, at its discretion, repair any structural defect which materially affects the performance of the spray unit, or replace the spray unit. For six (6) months from the date of purchase, the manufacturer will provide replacements for parts that prove to be defective in material or workmanship. Labor costs associated with repair or replacement work covered by this Sunless Express™ Limited Lifetime Warranty will be reimbursed for repair or replacement work required to be performed during the thirty (30) day period following the shipping date of your spray unit. Normal wear and tear, damage from misuse or abuse, damage incurred in transit or damages resulting from unauthorized repairs or modifications, or the use of unauthorized spray solutions, are not covered by this warranty. Warranty coverage does not include cosmetic abnormalities such as scratches, nicks or dents that do not materially interfere with the function of the spray unit. THIS SUNLESS EXPRESS™ LIMITED LIFETIME WARRANTY IS EXPRESSLY MADE IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. No one has the authority to change or modify this Sunless Express™ Limited Lifetime Warranty in any respect. IN NO EVENT SHALL THE MANUFACTURER OR DISTRIBUTOR OF YOUR SPRAY UNIT BE LIABLE AT LAW OR IN EQUITY FOR ANY LOSS, LIABILITY, DAMAGE OR EXPENSE IN AN AMOUNT IN EXCESS OF THE PURCHASE PRICE RECEIVED, OR FOR LOSS OF USE OR PROFITS, LOSS OF TIME, INCONVENIENCE, RENTAL OR SUBSTITUTE PRODUCTS, LOSS OF BUSINESS, LOSS OF INCOME, OR ANY OTHER INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Sunless Express™ Limited Lifetime Warranty gives you specific, legal rights and you may have other rights which may vary from state to state. All warranty service must be performed by an authorized Sunless Express™ service person. All labor charges must be authorized by the manufacturer prior to the start of repairs and must not exceed the established rates and time allotment policies established by the manufacturer. If your spray unit must be returned for service, all freight charges shall be at your expense. This warranty is extended to the individual or legal entity whose name appears on the original sales document and may not be transferred to any other individual or legal entity. This warranty is void if the spray unit is modified in any manner from its original design or if the spray unit is used with a spray solution other than one supplied by ETS, Inc. 24389-01A To file a Warranty Claim, please follow these steps: 1. Locate the serial number on the spray unit, found (to be determined). 2. Proof of purchase must be provided before any claim will be considered. 3. Contact the Sunless Express™ Service Hotline at 877-783-8368. 18 Sunless Express™ Spray Spa Size Weight (Pounds) Minimum Room Size Electrical Voltage (AC) Amperage Circuit Breaker (Amps) Outlet (NEMA standard) Remote Capability 950 7’ wide x 9’ long x 10’ tall 110 13 20 5-20R T-Max® compatible CALL FOR SERVICE OR QUESTIONS: 1•877•783•8368 6270 Corporate Drive, Indianapolis, IN 46278-2900