24389-01A SE `02 spreads

Transcription

24389-01A SE `02 spreads
24389-01A
Come in from the sun
Welcome to a new generation of tanning products. While the concept
of ‘sunless tanning’ lotions is not a new one, technology has finally caught
up. The Sunless Express™ Spray Spa is the culmination of countless hours of
research on methods of applying sunless tanning lotion.
Sunless tanning products work by creating a response with the top two layers
of your skin. Dihydroxyacetone, or DHA, reacts naturally with the protein in
your skin. A brown “tan” forms within approximately two to three hours after
your session, and continues to darken for up to 24 hours. The result is a substantive tan. It is absolutely water-resistant and diminishes only as the dead cells
of the skin flake off - usually one to two weeks.
DHA is a common chemical used in multiple ways throughout our normal
everyday lives. For example, DHA is often used as an additive in food and
cosmetics.
Please take the time to read through this guide to familiarize yourself with the
concept of sunless tanning and the proper usage of your new equipment.
Thank you, and Welcome once again!
24389-01A
i
Introduction - contents
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Get to Know the Sunless Express™ . . . . . . . . . . . . . . . . . . .1
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Before you tan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
During the tan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Safety features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
After the tan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Advanced controls . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Setting the clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Cleaning after use . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Before you turn out the lights . . . . . . . . . . . . . . . . . . .10
Changing/refilling solutions . . . . . . . . . . . . . . . . . . . . .11
Thorough periodic cleaning . . . . . . . . . . . . . . . . . . . .11
Mechanical inspection . . . . . . . . . . . . . . . . . . . . . . . .12
Component maintenance . . . . . . . . . . . . . . . . . . . . . .12
Remote Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Warranty information . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
24389-01A
Technical Information . . . . . . . . . . . . . . . . . . . . .back cover
ii
Safety Information
DANGER
Shock hazard.
Disconnect power
before servicing.
If the supply cord is
damaged, it must be
replaced by a special
cord available from the
manufacturer or its
service agent.
WARNING
This product does not contain a sunscreen and does not protect against
sunburn. Repeated exposure of
unprotected skin while tanning may
increase the risk of skin aging, skin
cancer, and other harmful effects to
the skin even if you do not burn.
Avoid spraying directly into eyes.
IMPORTANT
CAUTION
Read and follow all instructions
regarding use and operation of the
Sunless Express.
Press the Stop button at any time
to stop operations immediately.
88465
iii
24389-01A
This product is in compliance with applicable requirements of
UL 60335-1, IEC 335-2-23, and CAN/CSA-E335-1/3E-94.
Safety Information
DANGER
Risque de chocs électriques.
Débrancher l’alimentation électrique
avant de procéder à la réparation ou
à l’entretien de l’appareil.
Un cordon d’alimentation
endommagé doit être remplacé par un
cordon particulier pouvant être acheté
du fabricant ou d’un technicien.
AVERTISSEMENT
Ce produit ne contient pas d’écran
solaire et ne protège pas contre les
coups de soleil. L’exposition répétée
d’une peau non protégée aux rayons
ultraviolets peut accroître les risques
de vieillissement et de cancer cutané
et produirent d’autres effets nocifs
même en l’absence de coups de
soleil. Éviter de pulvériser le produit
dans les yeux.
IMPORTANT
MISE EN GARDE
Lire et suivre toutes les directives
d’utilisation et de fonctionnement
du spa Sunless Express.
Pour que l’appareil cesse
immédiatement de fonctionner,
appuyer en tout temps sur le bouton
Stop (Arrêt).
24389-01A
Ce produit est conforme aux normes de rendement dans le documents
UL 60335-1 , IEC 335-2-23 , CAN/CSA-E335-1/3E-94.
88465
iv
Getting to Know the Sunless Express™
(The tanning area)
SPEAKER
WASHDOWN NOZZLE
GANTRY
SPRAY NOZZLE
SPRAY MANIFOLD
24389-01A
1
Getting to Know...
(Lower section of Control Cabinet)
WATER HEATER
AIR PUMP
PUMPS (see next page)
DISINFECTANT
24389-01A
TANNING LOTION
2
Getting to Know...
WASHDOWN SOLENOID
EVACUATION FAN
(at top of cabinet)
PERISTALTIC PUMP
EVACUATION PUMP
24389-01A
3
Getting to Know...
(Control Module)
RS-232 PORT
(not currently used)
T-MAX LINK
CONTROL PORT
REMOTE PORTS
(not currently used)
LIGHTS
WASHDOWN
CONTROL PAD
24389-01A
MASTER POWER
4
Operation
Operation of the sunless tanning booth
requires just two buttons. The first is the
“Start/Stop” button on the Sunless
Express™ Remote Control (SERC) supplied with the booth (see illustration 1).
Pressing this button sends a signal to the
booth to allow a single session to run.
After the session is complete the display
on the SERC will indicate a “..” meaning
the room needs to be sanitized. After
cleaning the unit press the up (▲) button
on the SERC until a “0” appears.
Illustration 1 (SERC)
Once the “Start/Stop” button (on the SERC)
is pressed the booth receives the signal
and is ready for the session. Enter the
booth, close the door and an automated
voice will explain the sunless tanning
experience. Press the green “Start” button
on the wall to begin (see illustration 2).
The SERC is also capable of telling the
booth to run two back-to-back sessions
without resetting. To do this, press the up
(▲) button until the display shows a “4”
(signifying the Spray Manifold will make
four passes over your body).
Read on for tanning instructions as well as
a complete script of the tanning session.
Refer to Remote Connections - Operation
with remote for operation while connected to a T-Max® remote system.
5
24389-01A
Illustration 2
Operation - the tanning session
Before you tan
During the tanning session
For best results, exfoliate before using the Upon closing the door you will hear the
tanning unit.
following instructions...
Do not use lotion on your body before
you tan. This may act as a barrier and prevent some areas from getting tan.
“Welcome to the Sunless Express™
spray spa! For best results, follow the
instructions exactly. Please place your
feet in the boxes and stand as close to
the door as possible. Point your toes
toward the sides. Place your arms
above your head and bend elbows
slightly. Palms should be facing forward. Raise your chin upward. To hear
the instructions again open the door
and close it one time. Press the green
start button to begin your session and
again, place your hands above your
head, palms facing forward.”
Remove any makeup from face.
Remove contacts.
Remove all jewelry.
Women: Place the shower cap right at the
hairline. This will prevent any unnecessary tan lines on your forehead.
Men: If you have a receding hair-line or
balding - to prevent tan-line, do not wear
the shower cap unless your hair is naturally very light or is chemically lightened.
See the chart located on the rear wall of
Apply neutralizing lotion to hands and the booth for complete positioning
toes with special attention to cuticle cov- instructions. Pressing the “Start” button
erage. Be careful not to apply neutraliz- will begin the tanning session.
ing lotion to areas you want tan as white
“At the end of the countdown, close
spots will result. You may remove any
your eyes and hold your breath as the
misplaced blocker with a moisture wipe.
spray passes your upper body. 3,2,1.”
24389-01A
The spray mist will coat the front of your
body.
6
Operation - the tanning session
Safety features
“You may open your eyes and breathe
freely. Please turn around and face the
door. Please place your feet in the
boxes and stand as close to the door
as possible. Point your toes toward the
sides. Place your arms above your
head and bend elbows slightly. Palms
should be facing the door. Press the
green start button to begin your session and again, place your hands
above your head, palms facing the
door.”
Panic Stop Button - Pressing the “Stop”
button will immediately end the session at
any time.
Gantry Safety Mechanism - If there is any
pressure placed on the spray manifold during operation, the unit will stop and the
session will end. Check the mechanism for
any obstructions before using again.
After the tan
7
24389-01A
After your session, you will notice a light
“At the end of the countdown, close mist on your body. First, wipe your hands
your eyes and hold your breath as the
with the moisture wipes. Next, gently
spray passes your upper body. 3,2,1”
wipe the rest of your body, as if getting
The spray will now coat the back side of out of the shower. When you are completely dry, wipe your hands again with
your body.
the moisture wipes in case your hands
“Thank you for using the Sunless
came in contact with the solution while
Express™ spray spa. At this time you drying off. Be sure you are completely dry
may open your eyes and breathe before getting dressed. This will eliminate
freely. Upon exiting the spa, please most of the bronzer residue on the inside
dry off with the towels provided. of your clothing.
Enjoy your tan.”
You will not notice a lot of immediate
color from your session. The tan will begin
to develop within 2 to 3 hours after the
session and continue to darken for up to
24 hours. Wait 4-6 hours before showering
or engaging in activities which encourage
persperation as this will wash the bronzer
off your body before it has enough time to
affect the color of your skin.
Operation - advanced controls
The Control Pad, located on the Control Module, offers
additional controls for the salon owner. The illustration
at right shows the “Home” screen, with the time and a
scrolling message. After making adjustments, waiting
10 seconds will return the screen to “Home”.
Execute [☞] - press to enter modes and select
options
Up [▲]
- scrolls options upward
Down [▼] - scrolls options downward
Cycle Count
Status
Home [☞]
[☞]
[▲]
Tanning
[▼]
[▲]
[▼]
[☞]
Booth [☞]
Displays number of complete sessions
performed
[▲] Door Status (open/closed)
[▼]
Light Status (on/off)
Software Vers [☞]
Displays software version number
Sound Version [☞]
Displays voice version number
Tanning Cycle [☞]
Starts a tanning cycle. Press [☞] again
to finish the cycle
Washdown Cycle[☞] Starts a washdown cycle
Controls [☞]
24389-01A
[▲]
[▼]
Settings [☞]
[▲]
[▼]
Panic
[☞]
Interrupts the tanning session
Booth Lights
[☞]
Turns lights on and off
Clock
[☞]
Set time (see next page)
[☞]
[▲]/[▼] to adjust volume
[☞]
Resets position of spray manifold
[▲]
[▼] Volume
Calibrate
8
Operation - advanced controls
Setting the clock
From the “Home” screen, press Execute
[☞] to enter the option mode. Scroll
through the three options using the Up
[▲] or Down [▼] buttons, until you reach
the Settings option. Press [☞] again to Home [☞]
enter the Settings menu.
Scroll to the Clock option and press [☞].
The hours digit on the time will blink.
Press [▲] or [▼] until the desired hour is
displayed. Press [☞]. The minutes blink.
Set the minutes and press [☞] and then
[▲] or [▼] to set am or pm. Wait a few
seconds or press [☞] one more time to
exit the setting mode.
[▲]
[▼]
Settings [☞]
[▲]
[▼]
Clock [☞]
Hours blink
[▲]/[▼] to adjust hours.
[☞]
to set
Minutes blink
[▲]/[▼] to adjust minutes.
[☞]
to set
am or pm blinks
[▲]/[▼] to select.
9
24389-01A
[☞]
to set
Care and Maintenance
Your Sunless Express™ spray spa has been
Cleaning after use
designed and engineered for years of serv- After each use it is necessary to clean and
ice. However, much like changing the oil disinfect the booth by activating the
in your car, there are some care and main- Washdown cycle.
tenance issues to keep in mind. The next
1. Close the door and press the
few pages outline the various periodic
Washdown button on the Control
duties you need to perform broken down
Module located in the Control
by frequency. Refer to the pictures in
Cabinet.
Getting to Know the Sunless Express™.
2. After the Washdown cycle is complete, wipe the internal walls. You
may use the squeegee provided or a
soft towel.
WARNING
3. Disinfect and dry the step and door
Shock hazard.
handles.
Disconnect power before servicing.
4. Reset the remote control unit by
holding the up button until the display reads “0”.
Before you turn out the lights
At the end of each day of usage there are
a few things to check to make sure the
unit continues to function satisfactorily.
24389-01A
1. Stand the inside mat up on edge to
allow it to dry and encourage air
movement within the base cavity.
2. Be sure to leave the door open.
3. Check the level of tanning and disinfectant solution. Try not to let the levels drop below about 1 1/2 inches to
avoid running dry.
10
Care and Maintenance
Thorough periodic cleaning
Changing/refilling solutions
On a monthly basis a little extra care is For best results, the level of tanning soluneeded.
tion and disinfectant should not be less
1. Thoroughly clean the internal walls, than 1 1/2 inches. When changing solurubber seals and spray manifold to tions you may pour any remaining liquid
from the used bottle into the new one if
remove any solution residue.
there is enough room in the new bottle.
2. Remove the Floor Mat and Floor Mat
1. Lift the tanning solution and/or disinPlate and use a hose to spray them
fectant container out of the Spill Tray
off.
and place on the floor.
3. Clean the outside of the unit as
2. Remove the cap, complete with the
needed using non-ammonia cleanhose, from the used container.
ers.
3. Remove the cap from the replace4. Replace the solution bottle with one
ment container and screw onto the
containing only water and run the
used container to save any unused
unit for a complete cycle to purge
solution.
the system.
4. Insert the solution filter hose into the
5. While the solution bottle is removed,
new container and secure the cap.
rinse the solution filters in warm
water.
5. Place new bottle into Spill Tray.
6. Check to verify the solution filter
hose touches the bottom of the container.
24389-01A
11
Care and Maintenance
24389-01A
Mechanical inspection
Along with the monthly thorough cleaning, inspect the unit’s mechanical integrity.
1. Inspect all bolts, nuts, screws and
other fasteners to make sure all are
secure.
2. Check door hinges for signs of wear.
3. Pay special attention to the Spray
Manifold track system and belt for
signs of wear. This is the heart of the
unit.
4. Inspect the counterweight for
smooth movement by sliding it up
and down its guide. It should glide
freely.
5. Check all hose connections, pumps,
valves and water heater for leaks.
6. Make sure the AC power cord is in
good shape and firmly plugged in at
both ends.
7. Check all filters and clean or replace
those which appear dirty.
8. Check proper operation of the gantry
safety system...
With the solution system off, turn
unit on. Press down on the Spray
Manifold as it rises. It should stop
without much force.
9. Clean the spray nozzles carefully.
12
Component maintenance
1. Purge the water heater per manufacturers requirements.
2. Maintain Waster pump per manufacturers requirements.
3. The Evacuation Fan needs no regular
maintenance.
4. Clean unit as described in Thorough
periodic cleaning.
Remote Connections
T-Max® Products
Your Sunless Express™ remote control
unit incorporates advanced circuitry
allowing it to connect and communicate
with the popular T-Max® remote control
systems. The booth can be connected to
any T-Max Manager or 1A or 3A. Refer to
the appropriate section that follows.
T-Max® Manager Remote System
This system is ideal for multiple sunbed
installations, including the Sunless
Express™. Simply connect the RJ-22 modular cable(s), described in the T-Max®
Manager manual, into the remote port(s)
located on the back of the Sunless
Express™ Remote Control (SERC) and follow the instructions that came with your
remote system. If you have an older TMax® Manager that does not support auto
addressing, set the address of the SERC
manually as described in Setting the
address manually. You can place your
booth at any location in the series (see
illustration below).
T-Max® 1A and 3A Remote Systems
The T-Max® 1A and 3A can offer the
same control as the T-Max® Manager in
single unit installations. If you’re using a
1A, it must have a chip labelled “master”
installed on its circuit board.
After you have set the T-Max® 1A’s, or
3A’s, address to “0” (refer to your T-Max®
user’s guide) and the SERC’s address to
“1”, simply connect the RJ-22 modular cables, described in the T-Max®
user’s guide, directly into
either port located on the
back of the SERC and
either port on the back
of the T-Max® 1A or 3A.
Setting the address manually
Before connecting the SERC to the TMax® Manager or T-Max® 1A or 3A, the
address must first be set. Set the address
manually as described below.
1. Remove power from the T-Max®
Manager or 1A or 3A.
2. Plug in the SERC. It should show “9.9”
on the display and sound an alarm. If
it just shows “0” go to step 4.
13
24389-01A
3. Press and release the Start/Stop button.
The display will flash “8.8” and the
alarm will stop. Press the Up button
until the display stops flashing and
shows a “0”.
Section - subheading
4. Press and hold the Start/Stop and Up
buttons simultaneously until a “.1”
appears. This may take about 5-6 seconds. Release the buttons.
5. Press the Start/Stop button. A flashing
number will appear. This is the address
that the SERC is set to.
6. Press the Up or Down button until the
desired address is displayed.
Note: When setting the addresses,
remember these three rules;
• Each tanning unit in the salon
(including the SERC) needs a unique
address.
• Do not set the SERC to “00”.
• If the period is flashing, you are over
address 100.
7. Once the desired address is displayed,
press and release the Start/Stop button.
A steady “.1” will be displayed.
24389-01A
8. Press and hold both the Up and Down
buttons until a “0” is displayed.
Operation with remote
When connected to a T-Max® system the
unit operates differently than explained in
Operation. The session is activated from
the Manager, 1A or 3A. To activate a single session send a 2 from the remote (refer
to your T-Max® manual). For a double
session, send a four (4). This will activate
the unit and the session starts when the
tanner enters the booth and presses the
Start button inside the unit. The use of two
and four correspond to the number of
passes the Spray Manifold will make over
your body during the session.
9. Connect the SERC into the remote After the session is complete the SERC
will display “..” indicating the room needs
series.
cleaning. Refer to Care and Maintenance
- Cleaning after use for cleaning instructions. After cleaning, press the Up button
on the SERC to clear the “..” indication
and ready the unit for the next session.
14
Notes
24389-01A
15
Troubleshooting
Problem
Solution
Overhead lights not working
1. Check power supply to unit
2. Check light power cord to control module
3. Press lights button on control module
4. Replace light(s)
Unit will not start session once the 1. Is the SERC displaying a flashing decimal after
the 0? If not, press the “Start/Stop” button
green button is on
2. Check supply cord to switch
Unit stops in mid session
1. Check gantry/belt for interference
2. Check counterweight for interference
3. Check gantry/belt for clip disconnection
4. Manifold may have tripped the safety
switch
24389-01A
Manifold is not moving during session 1. Check gantry/belt for interference
2. Check counterweight for interference
3. Check gantry/belt for clip disconnection
4. Manifold may have tripped the safety
switch - Safety signal will be voiced
Unit will not work with T-Max®
1. Check all connections
2. Make sure each unit has a unique address
3. Has the T-Max® Manager been disconnected
4. Has the T-Max® system been set-up correctly
Solution is not coming through
nozzles , air only
1. Check solution level
2. Check peristaltic pump for proper action
3. Check solution hoses and connections for
leaks or disconnection
16
Troubleshooting
Problem
Solution
Air is not coming through nozzles, 1. Check air hoses for disconnection
2. Check air pump for proper function
solution only
Manifold making loud pounding Unit has not made contact with limit switch
or bottom of cycle. Adjust switch.
noise at the top
Nothing comes on
1. Check main power and connection
2. Check GFCI
3. Check control Module fuse
Footwash feels cold
1. Check heater setting
2. Check power cord connection
Footwash not working
Check solenoid and or harness connection
Washdown not working
Check solenoid and or harness connection
Users are consistently darker on one Check nozzles for clogs
side
The unit is overly foggy during session 1. Check ventilation fan power supply
2. Check duct connections
3. Replace ceiling filter
24389-01A
17
Warranty
Sunless Express™ LIMITED LIFETIME WARRANTY
The manufacturer of your Sunless Express™ spray unit warrants your spray unit to be free of structural defects in
its material and workmanship, under normal use, for its lifetime. The manufacturer will, at its discretion, repair
any structural defect which materially affects the performance of the spray unit, or replace the spray unit.
For six (6) months from the date of purchase, the manufacturer will provide replacements for parts that prove
to be defective in material or workmanship. Labor costs associated with repair or replacement work covered by
this Sunless Express™ Limited Lifetime Warranty will be reimbursed for repair or replacement work required
to be performed during the thirty (30) day period following the shipping date of your spray unit. Normal wear
and tear, damage from misuse or abuse, damage incurred in transit or damages resulting from unauthorized
repairs or modifications, or the use of unauthorized spray solutions, are not covered by this warranty. Warranty
coverage does not include cosmetic abnormalities such as scratches, nicks or dents that do not materially interfere with the function of the spray unit.
THIS SUNLESS EXPRESS™ LIMITED LIFETIME WARRANTY IS EXPRESSLY MADE IN LIEU OF ANY
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. No
one has the authority to change or modify this Sunless Express™ Limited Lifetime Warranty in any respect.
IN NO EVENT SHALL THE MANUFACTURER OR DISTRIBUTOR OF YOUR SPRAY UNIT BE LIABLE AT
LAW OR IN EQUITY FOR ANY LOSS, LIABILITY, DAMAGE OR EXPENSE IN AN AMOUNT IN EXCESS
OF THE PURCHASE PRICE RECEIVED, OR FOR LOSS OF USE OR PROFITS, LOSS OF TIME, INCONVENIENCE, RENTAL OR SUBSTITUTE PRODUCTS, LOSS OF BUSINESS, LOSS OF INCOME, OR ANY
OTHER INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES. Some states do not allow
the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This Sunless Express™ Limited Lifetime Warranty gives you specific, legal rights and you may
have other rights which may vary from state to state.
All warranty service must be performed by an authorized Sunless Express™ service person. All labor charges
must be authorized by the manufacturer prior to the start of repairs and must not exceed the established rates
and time allotment policies established by the manufacturer. If your spray unit must be returned for service, all
freight charges shall be at your expense. This warranty is extended to the individual or legal entity whose name
appears on the original sales document and may not be transferred to any other individual or legal entity. This
warranty is void if the spray unit is modified in any manner from its original design or if the spray unit is used
with a spray solution other than one supplied by ETS, Inc.
24389-01A
To file a Warranty Claim, please follow these steps:
1. Locate the serial number on the spray unit, found (to be determined).
2. Proof of purchase must be provided before any claim will be considered.
3. Contact the Sunless Express™ Service Hotline at 877-783-8368.
18
Sunless Express™ Spray Spa
Size
Weight (Pounds)
Minimum Room Size
Electrical Voltage (AC)
Amperage
Circuit Breaker (Amps)
Outlet (NEMA standard)
Remote Capability
950
7’ wide x 9’ long x 10’ tall
110
13
20
5-20R
T-Max® compatible
CALL FOR SERVICE OR QUESTIONS: 1•877•783•8368
6270 Corporate Drive, Indianapolis, IN 46278-2900