legend symbol description
Transcription
legend symbol description
GENERAL NOTES: 1. GENERAL SCOPE OF WORK 20. OPERATION AND MAINTENANCE MANUALS 1.1. FURNISH ALL LABOUR, MATERIALS, EQUIPMENT, TOOLS AND SUPPORTS AS WELL AS SUPERVISION TO 20.1. SUBMIT 5 COPIES OF O&M MANUALS TO ENGINEER FOR REVIEW. ALSO INCLUDE 1 COPY IN PDF FORMAT PROVIDE A COMPLETE INSTALLATION, TESTED AND IN WORKING ORDER, AS SHOWN ON THE DRAWINGS. CONTRACTOR RED LINES AND O&M MANUAL. MANUALS SHALL INCLUDE SHOP DRAWINGS OF ALL NEW 1.2. THE CONTRACTOR SHALL PERFORM THE WORK STIPULATED IN THE CONTRACT AND ANY OR ALL CONTRACT EQUIPMENT, TEST AND BALANCING REPORTS, COMMISSIONING REPORTS, WARRANTIES, AND OPERATION, CHANGES AND CHANGE DIRECTIVES, AND SHALL FURNISH, UNLESS OTHERWISE PROVIDED IN THE MAINTENANCE PROCEDURES AND AS BUILT DRAWINGS. CONTRACT, EVERYTHING NECESSARY FOR THE PROPER PERFORMANCE AND COMPLETION OF THE WORK. 1.3. ALL WORK SHALL BE FULLY TESTED, COMMISSIONED AND IN GOOD WORKING ORDER AT TIME OF 21. TESTING, ADJUSTING AND BALANCING (T.A.B.) HAND-OVER TO OWNER. 21.1. INCLUDE ALL TESTING, ADJUSTING AND BALANCING FOR AIR SYSTEMS INCLUDING, BUT NOT LIMITED TO, 1.4. MAKE GOOD ANY DAMAGES TO EXISTING EQUIPMENT AND/OR SYSTEM(S). COORDINATE WORK AND THE FOLLOWING: WORKING HOURS WITH THE OWNER AND OTHER TRADES TO MINIMIZE DISRUPTION. 21.1.1. ALL NEW HVAC EQUIPMENT 2. CODES, STANDARDS AND CERTIFICATIONS 21.1.2. ROOFTOP UNITS (RTU) 2.1. ALL WORK SHALL CONFORM TO THE MOST RECENT ISSUES OF: 21.1.3. MAKE-UP AIR UNIT, CO, NxOx SYSTEM, EXHAUST FANS. 2.1.1. THE ONTARIO BUILDING CODE 21.1.4. REPORT TO INCLUDE FLOWS, PRESSURES, VELOCITIES AND OTHER PERTINENT PERFORMANCE 2.1.2. THE ONTARIO ELECTRICAL SAFETY CODE DATA FOR AIR AND WATER. REPORT SHALL ALSO INCLUDE POWER, AMPS, VOLTAGES, 2.1.3. THE MINISTRY OF THE ENVIRONMENT PERFORMANCE CURVES, SETTINGS OF ALL SETPOINTS AND SAFETIES, AND ALL OTHER 2.1.4. THE NATIONAL ELECTRICAL CODE INFORMATION THAT MAY BE REQUESTED BY THE OWM START-UP FORMS, THE ENGINEER OR 2.1.5. BYLAWS AND REGULATIONS ISSUED BY THE BUILDING AUTHORITY HAVING JURISDICTION THE COMMISSIONING AGENT. 2.1.6. AHRI 21.2 INCLUDE REPORT IN THE OPERATION AND MAINTENANCE MANUALS 2.1.7. ASHRAE 21.3. 2.1.8. ASME SUBMISSION OF REPORT. 2.1.9. SMACNA 21.4 BALANCING SHALL BE PERFORMED BY AN AABC OR NEBB CERTIFIED BALANCER 2.1.10. NFPA 22. REMOVE ALL ABANDONED PIPES, HANGERS, INSERTS, CONDUITS, DUCTS AND SERVICES. 2.1.11. TSSA FIRESTOP AND SEAL ALL AFFECTED AREAS. 2.1.12. CSA 2.1.13. CGA 23. SEAL AND FIRESTOP ALL WALL, FLOOR AND ROOF PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED ASSEMBLIES. 3. SPECIFICATIONS 3.1. COMPLY WITH THE GENERAL SECTIONS AND APPLICABLE SECTIONS OF THE GENERAL CONTRACT 24. CONTRACTOR MUST ASSURE THAT ALL PIPING CROSSING PASSAGEWAY/GARAGE DOORS/ETC.. SHALL SPECIFICATIONS. BE INSTALLED ABOVE AS NOT TO REDUCE OR PREVENT PENETRATION UNLESS THE PIPING IS LOCATED 4. WARRANTY AGAINST THE CEILING OF SUCH SPACE AND PERMITTED BY THE AUTHORITY HAVING JURISDICTION. 4.1. WARRANT ALL LABOUR AND MATERIALS INCLUDED IN THIS CONTRACT FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE. ASSUME FULL RESPONSIBILITY FOR LAYOUT OF ALL WORK AND FOR ANY 25. ALL NEW EQUIPMENT CONTROL PANELS MUST BE STANDALONE AND FULLY (7/24) PROGRAMMABLE. DAMAGE CAUSED TO OWNER OR OTHERS BY IMPROPER CARRYING OUT OF THE WORK. 26. DUCT FLEXIBLE CONNECTIONS MUST BE INSTALLED AT INLETS AND OUTLETS OF SUPPLY AND EXHAUST 5. DRAWINGS CONNECTIONS FOR FURNACES AND ENERGY RECOVERY VENTILATOR UNITS. 5.1. DRAWINGS SHOW GENERAL INTENT OF THE WORK AND PROPOSED ROUTING ONLY. 5.2. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS BY FIELD MEASURE BEFORE 27. CO-ORDINATE ALL DIMENSIONS WITH EQUIPMENT SHOP DRAWINGS. PROCEEDING WITH THE WORK. 28. WELDING SHALL BE UNDERTAKEN BY A COMPANY CERTIFIED BY CANADIAN WELDING BUREAU UNDER 5.3. CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING POSSIBLE INTERFERENCES AND INFORMING THE REQUIREMENTS OF DIVISION 1 OR DIVISION 2.1 OR W47.1. ENGINEER PRIOR TO STARTING ANY WORK. 6. SITE CONDITIONS 6.1. THE CONTRACTOR SHALL INFORM THE ENGINEER IN WRITING OF ANY ADDITIONAL DIFFICULTIES, INTERFERENCES AND SITE CONSTRAINTS THAT MAY BE IDENTIFIED DURING THE CONSTRUCTION PERIOD. 6.2. ALL NOISY WORK SHALL BE PERFORMED DURING NORMAL BUSINESS HOURS: BETWEEN 9AM AND 5PM, MONDAY THROUGH FRIDAY. 6.3. COORDINATE SITE ACCESS AND DELIVERIES WITH GENERAL CONTRACTOR. 29. MATERIALS AND WORK WHICH FAILS TO MEET SPECIFIED REQUIREMENTS WILL BE REJECTED BY THE ENGINEER WHENEVER FOUND AT ANY TIME PRIOR TO FINAL ACCEPTANCE AND REGARDLESS OF PREVIOUS INSPECTIONS. WHEN REJECTED, DEFECTIVE MATERIALS OR WORK SHALL BE PROMPTLY REMOVED, REPLACED OR REPAIRED TO THE SATISFACTION OF THE ENGINEER AT NO EXPENSE TO THE OWNER. PERMITS AND FEES: 1. 7. CLEANING 7.1. CLEAN PREMISES DAILY AT THE END OF EACH WORK DAY. 7.2. DO NOT ACCUMULATE EQUIPMENT, TOOLS, DEBRIS AND WASTE MATERIALS ON SITE. REMOVE FROM SITE DAILY. 7.3. COMPLETELY REMOVE ALL DEBRIS AND RUBBISH FROM SPACE ONCE WORK IS COMPLETE. 7.4. ALL MATERIALS TO BE DISPOSED OF CONSTRUCTION SITE IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS. 8. OPEN FLAMES AND WELDING 8.1. NO OPEN FLAMES OR WELDING IS PERMITTED WITHIN THE BUILDING WITHOUT WRITTEN PERMISSION BY THE OWNER AND/OR THE ENGINEER. 8.2. HOT WORK PERMIT MUST BE VISIBLE AT ALL TIMES. 8.3. ADEQUATE NUMBER OF FIRE EXTINGUISHERS MUST BE PROVIDED DURING THE OPEN FLAME PROCESS. 2. 3. 10. MATERIALS 10.1. USE ONLY NEW CSA AND ULC CERTIFIED EQUIPMENT AND MATERIALS UNLESS OTHERWISE INDICATED. 10.2. ONLY FIRST CLASS WORKMANSHIP WILL BE ACCEPTED WITH RESPECT TO STANDARD PRACTICES, SAFETY, ACCESSIBILITY, DURABILITY AND NEATNESS OF INSTALLATION WORK. CONTROL WIRING DOMESTIC COLD WATER PIPE (DCW) DOMESTIC HOT WATER PIPE (DHW) SAN SANITARY PIPE (SAN) ABOVE GROUND SAN SANITARY PIPE (SAN) BELOW GROUND G NATURAL GAS PIPE (G) V VENT LINE STORM LINE ST CO UPTURNED CLEANOUT - BELOW GROUND CO HORIZONTAL CLEANOUT - ABOVE GROUND TEMPERATURE SENSOR/THERMOSTAT T SUPPLY DIFFUSER M WATER METER G GAS METER DRAIN C/W P-TRAP INV. INVERT TYP. TYPICAL CO/NOX CARBON MONOXIDE / NITROGEN DIOXIDE DETECTOR VALVE THE CONTRACTOR SHALL ENSURE THAT THE JURISDICTIONAL AUTHORITIES ARE NOTIFIED OF THE DATE FOR THE COMMENCEMENT OF THE WORK AND THE DATES OF ACTIVITY OF THE WORK FOR WHICH MUNICIPAL INSPECTORS ARE REQUIRED TO BE PRESENT. THE CONTRACTOR SHALL SEND A COPY OF ALL CORRESPONDENCES TO THE ENGINEER. FD FLOOR DRAIN FFD FUNNEL FLOOR DRAIN THE CONTRACTOR SHALL BE RESPONSIBLE SHOULD FAILURE OCCUR. FIRE RATED DAMPER AIR TERMINAL: TYPE PROTECTION OF THE WORK AND ADJACENT PROPERTY: 2. THE CONTRACTOR SHALL PROTECT THE WORK, THE SITE, AND ANY OTHER PROPERTY ADJACENT TO THE SITE FROM DAMAGE WHICH MAY ARISE AS A RESULT OF ITS OPERATIONS UNDER THE CONTRACT AND SHALL BE LIABLE FOR ANY DAMAGES WHICH MAY BE ACCESSIONED; AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING GOOD SUCH DAMAGES AT ITS EXPENSE IN THE MANNER DIRECTED BY AND TO SATISFACTION OF ENGINEER. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE TO PROVIDE FOR AND BEAR THE COSTS OF PREVENTATIVE MEASURES TO ACCOMMODATE THE FORCES OF NATURE, WHICH CAN RESULT IN FREEZING, FLOODING, OVERHEATING, OR SIMILAR CIRCUMSTANCES, WHICH OCCUR UNTIL CONTRACT COMPLETION. SCOPE OF WORK & PROJECT DESCRIPTION: ALL WORK AS INDICATED IN DRAWINGS AND SPECIFICATIONS. 11. SHOP DRAWINGS 11.1. SUBMIT 4 COPIES OF SHOP DRAWINGS, UNLESS OTHERWISE INDICATED, FOR ENGINEER'S REVIEW. 11.2. SUBMIT SHOP DRAWINGS AND PRODUCT DATA FOR ENGINEER'S REVIEW COVERING ALL RELEVANT DETAILS, DIMENSIONS AND PERFORMANCE. 11.3. SHOP DRAWINGS MUST BE REVIEWED, STAMPED AND SIGNED BY THE CONTRACTOR AND THE GENERAL CONTRACTOR PRIOR TO SUBMITTING TO CONSULTANT / ENGINEER FOR REVIEW. 2. CONTRACTOR SHALL PROVIDE HVAC EQUIPMENT, GAS PIPING, DUCTWORK, GRILLES, CONTROLS, PLUMBING EQUIPMENT AND FIXTURE ROUGH-INs AS SHOWN ON DRAWINGS AND SPECIFICAITONS ON DRAWING M-1 THROUGH M-4.1. 12. CUTTING, PATCHING AND PAINTING REQUIREMENTS 12.1. PROVIDE CUTTING, PATCHING AND PAINTING FOR ALL OPENINGS. USE QUALIFIED TRADES FOR THIS WORK. RESTORE FINISHES TO MATCH EXISTING SURROUNDINGS. 12.2. SUPPLY AND INSTALL APPROVED FIRESTOPS AS REQUIRED TO MAINTAIN FIRE RATING. 12.3. PIPING AND VENTS THROUGH WALL AND ROOF SHALL BE BY THE MECHANICAL DIVISION CONTRACTOR, INCLUDING ALL PATCHING. 1. THE CONTRACTOR SHALL HEREBY ASSUME THE DEFENSE OF, FULLY INDEMNITY AND HOLD HARMLESS THE OWNER, ITS ENGINEER, AGENTS AND EMPLOYEES IN RESPECT OF THE AMOUNT OF ANY CLAIM, DEMAND, LOSS, COST, EXPENSE (INCLUDING REASONABLE LEGAL EXPENSES), ACTION, SUIT, PROCEEDING, LIABILITY, FINE, PENALTY, INTEREST, PAYMENT OR DAMAGE (COLLECTIVELY REFERRED AS "CLAIMS") BY WHOMSOEVER (INCLUDING, WITHOUT LIMITATION, THE OWNER) WHICH IS MADE, SUSTAINED, BROUGHT OR PROSECUTED IN ANY MANNER BASED UPON, OCCASIONED BY OR ATTRIBUTABLE TO ANY BREACH OF THE CONTRACT BY THE CONTRACTOR, OR TO ANY WILLFUL MISCONDUCT, FAULT, OR NEGLIGENT ACT OR OMISSION OF THE CONTRACTOR OR ANY PERSON, AGENT, CONSULTANT, FIRM OR CORPORATION FOR WHOSE ACTS THE CONTRACTOR IS LIABLE AT LAW. FURTHER, THE CONTRACTOR SHALL PAY ANY AMOUNT OF CLAIMS INCURRED BY THE OWNER ON ACCOUNT OF ANY INJURIES, INCLUDING DEATH OR DAMAGES, RECEIVED OR SUSTAINED BY ANY PERSONS OR PROPERTY AND IF IT FAILS TO DO SO, THE OWNER MAY PAY SUCH CLAIMS AND DEDUCT THE AMOUNT THEREOF FROM ANY MONIES DUE, OR TO BECOME DUE, TO THE CONTRACTOR, OR OTHERWISE RECOVER SUCH AMOUNTS OR ANY BALANCE THEREOF FROM THE CONTRACTOR. AIR VOLUME (CFM) SIZE OR NECK DIA. (IN) FLUSH MOUNTED INTERIOR/EXTERIOR NON-FREEZE HOSE BIBB. GM GAS METER BFP BACK FLOW PREVENTER BBH U/C BASE BOARD HEATER UNDER CUT DOOR GRILLE 'EF-1' EXHAUST FAN FFH FAN FORCED HEATER RETURN DUCT DOWN INDEMNIFICATION: 14. PENETRATIONS THROUGH FLOORS AND WALLS 2. SUBJECT TO ANY SUPPLEMENTARY CONDITION WITH RESPECT TO THE PAYMENT OF LIQUIDATED DAMAGES, IF 14.1. UNLESS OTHERWISE SPECIFIED ON DRAWINGS, GLASS FIBRE FIRE RETARDANT INSULATION AND APPLICABLE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER PARTY FOR ANY CONSEQUENTIAL DAMAGES, FIRESTOP CAULKING SHALL BE PACKED AROUND PIPE OPENINGS IN FLOORS AND WALLS AT TIME OF PIPE INCLUDING, BUT NOT LIMITED TO, CLAIMS FOR LOSS OF PROFIT OR REPUTATION. INSTALLATION. FIRESTOP CAULKING SHALL BE "3M FIRE BARRIER" FIRETEMP CAULK OR EQUIVALENT. 14.2. APPLY FIRESTOP SYSTEMS IN ACCORDANCE WITH 3M'S INSTRUCTIONS. ALL SYSTEMS SHALL MEET CSA EMERGENCIES: F-SYSTEM RATINGS FOR THE PARTICULAR FIRE RATING OF THE PENETRATED SURFACE. 14.3. FIRESTOPPING CONTRACTOR MUST BE A LICENSED 3M CERTIFIED INSTALLER (REFER TO LIST IN 1. THE ENGINEER HAS THE DISCRETIONARY AUTHORITY IN AN EMERGENCY TO STOP THE PROGRESS OF THE SPECIFICATION PACKAGE). WORK WHENEVER SUCH STOPPAGE MAY BE NECESSARY TO ENSURE THE SAFETY OF LIFE, THE WORK, OR 14.4. MATERIALS SHALL BE ASBESTOS-FREE ELASTOMERIC MATERIALS, TESTED, LISTED AND LABELED BY ULC NEIGHBORING PROPERTY OR TO AVOID THE DISRUPTION OF THE OWNERS' WORK AND SERVICES. THIS IN ACCORDANCE WITH CAN 4-S115-M85, AND CAN/ULC-S101-M FOR INSTALLATION IN ULC DESIGNATED INCLUDES AUTHORITY TO MAKE CHANGES IN THE WORK. IN SUCH A CASE, IF WORK HAS BEEN PERFORMED BY FIRE STOPPING AND SMOKE SEAL SYSTEMS, TO PROVIDE A POSITIVE FIRE, WATER AND SMOKE SEAL AND THE CONTRACTOR UNDER DIRECT ORDER OF THE ENGINEER, THE CONTRACTOR SHALL HAVE THE RIGHT TO A FIRE RESISTANCE RATING (FLAME, HOSE STREAM AND TEMPERATURE) NOT LESS THAN THE FIRE RATING CLAIM THE VALUE OF SUCH WORK. FOR SURROUNDING CONSTRUCTION. MATERIALS SHALL BE COMPATIBLE WITH ABUTTING DISSIMILAR MATERIALS AND FINISHES. 15. DIELECTRIC ISOLATION 15.1. PROVIDE ISOLATION WHEN USING DISSIMILAR MATERIALS, TO PREVENT GALVANIC ACTION. DESCRIPTION NEW WORK THE CONTRACTOR SHALL APPLY FOR AND OBTAIN IN ITS OWN NAME, PERMITS, LICENSES, APPROVALS AND SHALL PAY FEES AND GIVE NOTICES NECESSARY PRIOR TO COMMENCING WORK AND INCIDENTAL TO THE DUE AND LAWFUL PERFORMANCE OF THE WORK, IN ACCORDANCE WITH THE SPECIFICATIONS. 1. 13. CORING REQUIREMENTS 13.1. FOR ALL CORING LESS THEN 3" DIA. CONTRACTOR SHALL BE RESPONSIBLE FOR SCANNING AREA PRIOR TO CORING THROUGH FLOORS/CEILINGS. 13.2. FOR ALL CORING GREATER THEN 3" DIA. CONTRACTOR SHALL BE RESPONSIBLE FOR X-RAYING AREA PRIOR TO CORING THROUGH FLOORS/CEILINGS. SYMBOL FRD 1. 9. FIRE EXTINGUISHERS 9.1. PROVIDE IN ACCORDANCE WITH NFPA 10 AND AUTHORITY HAVING JURISDICTION. 9.2. PROVIDE FIRE EXTINGUISHER AT EACH EXIT DOOR WAY OR AS INDICATED ON DRAWINGS. 9.3. MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER SHALL BE 75FT. 9.4. EXTINGUISHER SHALL BE 10Lb (OR AS INDICATED), MULTI-PURPOSE DRY CHEMICAL, STORED PRESSURE RECHARGEABLE TYPE, ULC LABELED FOR A, B AND C CLASS PROTECTION WITH SHUT-OFF NOZZLE AND WALL MOUNTING KIT. LEGEND GENERAL NOTES: SUPPLY DUCT DOWN RETURN / EXHAUST DUCT UP SUPPLY DUCT UP X XXX XX AIR TERMINAL:TYPE AIR VOLUME (L/S) SIZE OR NECK DIA.(mm) C/W COMPLETE WITH F.F. FINISHED FLOOR CTE CONNECT TO EXISTING DRAWING LIST DWG NO. DESCRIPTION M-1.0 GENERAL NOTES, SPECIFICATIONS, LEGEND AND DRAWING LIST M-1.1 PLUMBING, HVAC AND GAS PIPING NOTES M-1.2 DETAILS M-1.3 DETAILS M-1.4 SCHEDULES 16. VIBRATION ISOLATION 16.1. PROVIDE AND INSTALL MINIMUM 3/4" THICK MSN ELASTOMERIC PADS W/MOUNTS UNDER FLOOR MOUNTED HVAC EQUIPMENT AS PER MANUFACTURER RECOMMENDATIONS. M-1.5 PLUMBING FIXTURE SCHEDULE AND CO/NOX SPECIFICATIONS M-1.6 PLUMBING FIXTURE SCHEDULE 17. ELECTRICAL 17.1. ALL LOW VOLTAGE CONTROL WIRING (<50V) SHALL BE BY THIS DIVISION, TO ELECTRICAL DIVISION STANDARDS. M-2.0 GROUND FLOOR PLAN - PLUMBING AND DRAINAGE LAYOUT M-2.1 SECOND FLOOR PLAN - PLUMBING PLUMBING AND DRAINAGE LAYOUT M-2.2 ROOF PLAN - HVAC AND ROOF DRAIN LAYOUT M-2.3 PART GROUND FLOOR PLANS - PLUMBING AND DRAINAGE M-3.0 GROUND FLOOR PLAN - HVAC M-3.1 SECOND FLOOR PLAN - HVAC 18. PRESSURE TESTING 18.1. ALL PIPING SYSTEMS SHALL BE PRESSURE TESTED TO 860 kPa OR 1.5 TIMES SYSTEM OPERATING PRESSURE FOR A DURATION OF 24 HRS UNLESS OTHERWISE INDICATE. 19. AS BUILT DRAWINGS 19.1. MAINTAIN A RECORD OF ALL REVISIONS. PREPARE RECORD DRAWINGS IN A NEAT MANNER SHOWING ALL DEVIATIONS IN WORK. ON COMPLETION OF WORK, SUBMIT TO THE ENGINEER ONE HARD COPY OF AS BUILT DRAWINGS AND ELECTRONIC FORMAT DRAWINGS (IN AUTOCAD). PIPING, PLUMBING, FIXTURES AND ACCESSORIES: 1. GENERAL 1.1. MATERIAL AS INDICATED ON DRAWINGS. IF MATERIALS HAVE NOT BEEN INDICATED ON DRAWINGS, THEN INSTALLATION SHALL ADHERE TO THIS SECTION. 1.2. PROVIDE MATERIALS IN ACCORDANCE WITH THIS SECTION UNLESS OTHERWISE SPECIFIED. 1.3. PROVIDE ALL MATERIALS AS REQUIRED INCLUDING PIPING, VALVES, FITTINGS, TRAPS, HANGERS, SUPPORTS AND THERMAL INSULATION FOR COMPLETE SYSTEM INSTALLATION AND OPERATION. 1.4. PROVIDE MINIMUM PIPE INSULATION THICKNESSES IN ACCORDANCE WITH LATEST EDITION OF ASHRAE STANDARD 90.1 UNLESS OTHERWISE INDICATED. 1.5. PROVIDE ALL PLUMBING SYSTEMS, FIXTURES AND ACCESSORIES IN ACCORDANCE WITH OBC AND LOCAL AUTHORITIES HAVING JURISDICTION. PIPING, PLUMBING, FIXTURES AND ACCESSORIES: HVAC: (CONT'D) 15.1.1. CATCH BASIN SHALL BE PROVIDED COMPLETE WITH 8.6. ACCEPTABLE BLANKET MINERAL FIBER SHALL BE JOHNS MANVILLE MICROLITE DUCT WRAP 15.1.1.1. 4" SIDE OUTLET TYPE 100 OR EQUIVALENT. 15.1.1.2. EPOXY CAST IRON BODY 8.7. ACCEPTABLE RIGID MINERAL FIBERBOARD SHALL BE JOHNS MANVILLE 800 SERIES 15.1.1.3. ANCHOR FLANGE SPIN-GLASS TYPE OR EQUIVALENT. 15.1.1.4. 12.75"X12.75" SQUARE EPOXY COATED DUCTILE IRON HINGED GRATE 8.8. SEAL ALL JOINTS WITH ULC LISTED SELF-ADHESIVE INSULATION TAPE FOR INDOOR DUCTS 15.1.1.5. INTEGRAL TRAP WITH CLEANOUT PLUG AND INSULATION. 15.1.1.6. SEDIMENT BUCKET 8.9. USE RIGID INSULATION AND DRYWALL TYPE CORNER BEADS IN AREAS WHERE INSULATION 15.1.1.7. NO HUB OUTLET IS EASILY SUSCEPTIBLE TO DAMAGE. 15.1.1.8. SAFE LIVE LOAD OF 10,000LBS 15.2.6. CONTRACTOR SHALL REFER TO MANUFACTURER INSTALLATION REQUIREMENTS. 9. ACOUSTIC INSULATION 15.2.7. CATCH BASIN SHALL BE SIMILAR TO WATTS MODEL FD-430 SERIES OR APPROVED EQUAL. 9.1. ACOUSTIC INSULATION SHALL BE PROVIDED WHERE INDICATED ON DRAWINGS AND IN ALL RETURN AIR TRANSFER DUCTWORK AND WITHIN 15' OF EQUIPMENT FAN BLOWER. 2. THERMAL INSULATION 15.3. OIL INTERCEPTOR (INT-1) 9.2. ACOUSTIC INSULATION SHALL BE 1/2" THICK INTERNAL LINING, C/W FACTORY APPLIED 2.1. 15.3.1. OIL INTERCEPTOR SHALL BE FIBERGLASS REINFORCED PLASTICS PROVIDED COMPLETE BLACK ACRYLIC POLYMER COATING, HAVING FLAME SPREAD RATING OF 25 OR LESS AND WITH ELASTOMERIC THERMAL INSULATION. C/W FLEXIBLE ELASTOMERIC THERMAL INSULATION SMOKE DEVELOPMENT CLASSIFICATION OF 50 OR LESS. 15.3.1.1. EXTENSION COLLAR AND ASSHTO M306 TRAFFIC LOAD RATED COVER MESH COATING (FOR UV PROTECTION) FOR LOCATIONS WITH UV EXPOSURE. 9.3. DUCT SIZES SHOWN ON DRAWINGS INDICATE CLEAR INSIDE DIMENSIONS. 15.3.1.2. ACCESSWAYS, BAFFLES 2.2. FOR ALL OTHER PROCESSES AND PLUMBING PIPES: UNLESS OTHERWISE INDICATED, PROVIDE 9.4. ACCEPTABLE ACOUSTIC DUCT LINER SHALL BE JOHNS MANVILLE PERMACOTE LINACOUSTIC 15.3.2. INTERCEPTOR SHALL ACCEPT THE FOLLOWING CAPACITIES AND ENSURE ACCURATE AND INSTALL FIBERGLASS INSULATION WITH REINFORCED VAPOUR RETARDER FACING AND STANDARD/HP OR EQUIVALENT. OIL/SEDEMANT SEPARATION. FACTORY APPLIED ADHESIVE CLOSURE SYSTEM. INSULATION SHALL BE JOHNS MANVILLE 9.5. APPLY BLACK ACRYLIC POLYMER COATING TO ALL FIELD CUT EDGES AS PER SMACNA 15.3.3. OIL - 66 GAL MICRO-LOK AP-T PLUS OR EQUIVALENT. STANDARDS. 15.3.4. SOLID - 48 GAL 2.3. MINIMUM PIPE THICKNESSES SHALL BE IN ACCORDANCE WITH LATEST EDITION OF ASHRAE 9.6. ACCEPTABLE COATING SHALL BE JOHNS MANVILLE SUPERSEAL OR EQUIVALENT. 15.3.5. TOTAL - 150 GAL STD. 90.1. 15.3.6. CONTRACTOR SHALL REFER TO MANUFACTURER INSTALLATION REQUIREMENTS. 2.4. MINIMUM PIPE INSULATION SHALL BE 1" FOR ALL HOT WATER HEATING PIPES, CONDENSATE 10. FLEXIBLE CONNECTIONS 15.3.7. OIL INTERCEPTOR SHALL BE SIMILAR TO GREENTURTLE MODEL OMC 150 OR APPROVED LINE, DOMESTIC HOT AND COLD WATER PIPES UNLESS OTHERWISE INDICATED. 10.1. FLEXIBLE CONNECTIONS TO BE FIRE RESISTANT NEOPRENE COATED GLASS FABRIC. EQUAL. 2.5. DOMESTIC HOT WATER PIPES GREATER THAN 2" SHALL HAVE 1-1/2" THICK INSULATION. PROVIDE FLEXIBLE CONNECTIONS AT ALL DUCTED HVAC UNITs, ERVs, FANs AND WHERE 15.3.8. PROVIDE EXTERNAL OIL STORAGE TANK. 2.6. INDICATED ON DRAWINGS. 2.6.1. RUN OUTS (<13FT LONG): 1-1/2"; 11. GAS FIRED EQUIPMENT COMBUSTION AND VENTING (ROOFTOP UNIT AND UNIT HEATER) 2.6.2. PIPE UP TO: : 2" 11.1. GAS FIRED EQUIPMENT INSTALLATION AS PER MANUFACTURER RECOMMENDATION AND : 2-1/2" LOCAL APPLICABLE CODE. HVAC: : 3" 11.2. INSTALLATION AND VENTING PROVISIONS MUST BE IN ACCORDANCE WITH CAN/CSA : 3-1/2". STANDARD B149.1, ANSI Z223.1-NFPA 54, AND LOCAL AUTHORITIES HAVING 1. DUCTWORK JURISDICTION. SINGLE WALL TYPE B VENT PIPE MUST BE USED FOR HORIZONTAL 1.1. DUCTWORK SHALL BE CONSTRUCTED TO ASHRAE/SMACNA STANDARDS. 2.7. PROVIDE AND INSTALL PVC JACKET AND VAPOUR RETARDER (IF NOT PROVIDED ELSEWHERE) VENTING, DOUBLE WALL TYPE B VENT TO BE USED FOR VERTICAL VENTING. 1.2. DUCT SIZES ARE LISTED ON DRAWINGS. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE FOR INDOOR INSULATED PIPE APPLICATIONS. JACKETING SHALL BE JOHNS MANVILLE 11.3. VENTING SUPPORT DISTANCES SHALL BE AS PER MANUFACTURER RECOMMENDATIONS. DIMENSIONS. ZESTON 300 SERIES OR EQUIVALENT.(NOT NECESSARY FOR USE WITH MICRO-LOK AP-T PLUS) 11.4. ROOF/WALL PENETRATION PIECES SHALL BE ULC LISTED AND PROVIDED BY THE VENT 1.3. ALL FLEXIBLE DUCTWORK TO DIFFUSERS SHALL BE ALUMINUM SPIRAL, MAXIMUM LENGTH 2.8. PROVIDE AND INSTALL ALUMINUM JACKET WITH A LAMINATED MOISTURE RETARDER FOR MANUFACTURER. 10FT. OUTDOOR INSULATED PIPE APPLICATIONS. SECURE JACKET USING METAL BANDS AT BUTT 11.5. WHERE EXPOSED TO WEATHER, THE CASING JOINTS SHALL BE SEALED TO PREVENT 1.4. SEAL ALL NEW LOW PRESSURE DUCTS (<2IN.WC.) AND LOW PRESSURE DUCT JOINT OVERLAPS AND BETWEEN JOINTS. RAINWATER FROM ENTERING THE SPACE BETWEEN INNER AND OUTER WALLS. MODIFICATIONS TO SMACNA SEAL CLASS 'C' USING SEALANT OR ALUMINUM TAPE; OR A 2.9. INSTALL ALL INSULATION AND JACKETS AS PER MANUFACTURER RECOMMENDATIONS. 11.6. VENT SHALL TERMINATE IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS AND COMBINATION THEREOF. 2.10. MAINTAIN UNINTERRUPTED CONTINUITY AND INTEGRITY OF VAPOUR RETARDER AND LOCAL CODES. FINISHES. HANGERS AND SUPPORTS TO BE OUTSIDE VAPOUR OF RETARDER. 11.7. MAXIMUM HORIZONTAL VENT LENGTHS AS PER MANUFACTURER RECOMMENDATION AND 2. FLEXIBLE DUCTS (LOW PRESSURE) 2.11. APPLY HIGH COMPRESSIVE STRENGTH INSULATION, SUITABLE FOR SERVICE, AT OVERSIZED REQUIREMENTS. 2.1. NON-COLLAPSIBLE, COATED MINERAL BASE PERFORATED FABRIC TYPE HELICALLY SADDLES AND SHOES WHERE INSULATION SADDLES HAVE NOT BEEN PROVIDED 11.8. ALL ACCESSORIES (EXIT CONE, CONNECTORS AND DRAIN FITTINGS) WITH DIRECT OR SUPPORTED BY AND MECHANICALLY BONDED TO STEEL WIRE WITH FACTORY APPLIED 2.12. INSULATION SHALL BE FOIL FACED. INDIRECT CONTACT WITH CONDENSATE SHALL BE PROVIDED IN AL29-4C. FLEXIBLE GLASS FIBRE ACOUSTIC INSULATION AND ENCASED IN ALUMINUM FOIL AND 2.13. INSULATION SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE 11.9. PROVIDE ENGINEERED SHOP DRAWINGS OF SYSTEM FOR APPROVAL. MYLAR LAMINATE VAPOUR BARRIER. DEVELOPMENT CLASSIFICATION OF 50 OR LESS. 11.10. ACCEPTABLE MANUFACTURER: DURAVENT, HEATFAB OR APPROVED EQUAL. 2.2. MAXIMUM LENGTH SHALL BE 10FT. 2.3. DO NOT USE FOR EXPOSED CEILING APPLICATIONS. 3. PIPE HANGERS AND SUPPORTS 12. PACKAGED ROOFTOP UNIT (RTU) 3.1. PIPING HANGERS AND SUPPORTS SHALL BE SPACED IN ACCORDANCE WITH APPLICABLE 12.1. NATURAL GAS FIRED STAINLESS STEEL HEAT EXCHANGER C/W AUTOMATIC IGNITION, 3. ELBOWS CODES AND AUTHORITIES HAVING JURISDICTION. MINIMUM 80% EFFICIENCY. 3.1. FOR LOW PRESSURE SYSTEM: ELBOWS SHALL HAVE RADIUS OF NOT LESS THAN DUCT 3.2. PIPE HANGERS SHALL BE GRINNELL ADJUSTABLE CLEVIS TYPE OR EQUIVALENT. 12.1.1. FLAME ROLLOUT WIDTH. BARBER-COLEMAN "AIRTURNS", HART & COOLEY "DUCTURNS" TURNING VANES OR 3.3. EXTERIOR SUPPORTS SHALL BE S.S. GRINNELL OR EQUIVALENT 12.2. DX (R-410 REFRIGERANT) COOLING, SCROLL COMPRESSORS, CRANKCASE HEATER DUCTMATE TURNING VANES SHALL BE PROVIDED IN ELBOWS OF LESSER RADIUS IN ALL 12.2.1. HIGH PRESSURE SWITCH DUCTWORK. 4. PRESSURE TESTING 12.2.2. THERMOSTATIC EXPANSION VALVE 4.1. ALL PIPING SYSTEMS SHALL BE HYDROSTATICALLY PRESSURE TESTED TO A MINIMUM OF 860 12.3. CONSTANT VOLUME AIRFLOW C/W STARTERS TO MATCH HP kPa OR 1-1/2 TIMES SYSTEM OPERATING PRESSURE (WHICHEVER IS GREATER) FOR A PERIOD 4. VIBRATION ISOLATION 12.4. ACCESSORIES: UNIT TO BE COMPLETE WITH COIL GAURD, CONDENSATE DRAIN TRAP, 4.1. PROVIDE AND INSTALL MINIMUM 19mm THICK NSN ELASTOMERIC PADS W/ MOUNTS UNDER OF 24 HOURS UNLESS OTHERWISE INDICATED. DISCONNECT SWITCH, LIQUID & DISCHARGE SERVICE VALVES, BAROMETRIC RELIEF FLOOR MOUNTED HVAC EQUIPMENT AS PER MANUFACTURER RECOMMENDATIONS. DAMPERS AND EXHAUST HOOD, ECONOMIZER C/W DIFFERENTIAL ENTHALPY CONTROL AND PROVIDE AND INSTALL NEOPRENE OR SPRING W/ ELASTOMERIC WASHER OR SPRING W/ 5. DRAINAGE WASTE AND VENT PIPING (AS REQUIRED) MOTORIZED INTAKE DAMPER, MERV-8 DISPOSABLE AIR FILTERS, ELASTOMERIC ELEMENT HANGERS FOR CEILING SUSPENDED EQUIPMENT, DUCTWORK AND 5.1. ABOVE GROUND SANITARY, STORM AND VENT LINES LESS THAN 3" SHALL BE TYPE DWV TO STANDARD ROOF CURB. ACCESSORIES. ASTM B306 WITH CAST BRASS OR WROUGHT COPPER FITTINGS TO CAN/CSA B125. 12.5. ALL INFORMATION SHALL BE AS SCHEDULED ON DWG. M-1.4 OR APPROVED EQUAL. 5.2. JOINTS FOR COPPER TUBE/ PIPE SHALL BE TIN/ANTIMONY (95%/5%) SOLDER. 12.6. CONTRACTOR SHALL REFER TO MANUFACTURER INSTALLATION REQUIREMENTS. 5. BALANCING DAMPERS 5.3. PROVIDE TRAP PRIMERS WHERE REQUIRED. 12.7. ALL EQUIPMENT MUST MEET THE REQUIREMENTS OF THE LATEST EDITION OF ASHRAE 90.1. 5.1. BALANCING DAMPERS SHALL BE MANUALLY OPERATED OPPOSED BLADE OR SPLITTER TYPE. 5.4. ABOVE GROUND SANITARY, STORM AND VENT LINES 3" AND LARGER SHALL BE CAST IRON SPLITTER DAMPERS SHALL BE COMPLETE WITH CONTROL ROD, PIVOT BRACKET AND BALL HUB AND SPIGOT PIPE IN ACCORDANCE WITH THE LATEST EDITION OF THE OBC FOR SOIL 13. FAN-FORCED HEATERS (FFH-1) JOINT FITTING WITH LOCKING SETSCREW. AND WASTE. JOINTS SHALL BE CAULKED WITH WHITE OAKUM AND SECURED WITH MOLTEN 13.1. PROVIDE CAPACITIES AS INDICATED ON PLAN. 5.2. SPLITTER DAMPERS SHALL BE INSTALLED ON ALL BRANCH DUCT CONNECTIONS (OR LEAD NOT LESS THEN 1" DEEP. 13.2. UNITS SHALL BE PROVIDED WITH SINGLE-POLE BUILT-IN THERMOSTAT KIT AND LOW TAKE-OFFS) FROM DUCTS. 5.5. BURIED SANITARY, STORM AND VENT SHALL BE MINIMUM 3" CAST IRON TO CAN/CSA-B70, VOLTAGE RELAY. 5.3. OPPOSED BLADE DAMPERS SHALL BE USED FOR ALL DIFFUSER/GRILLE BALANCING JOINTS FOR CAST IRON SHALL BE HUB AND SPIGOT. 13.3. POWER REQUIREMENTS: 208V/1PH/60Hz DAMPERS (WHERE INDICATED). 5.6. PROVIDE AND INSTALL BACK WATER VALVE ON ALL FLOOR DRAIN. 13.4. FINISH: WHITE 13.5. SURFACE MOUNTED AND WALL RECESSED (PER DRAWING) 6. FIRE RATED DAMPERS (FRD) 6. DOMESTIC COLD AND HOT WATER PIPE 13.6. FAN-FORCED HEATERS SHALL BE STELPRO WF OR APPROVED EQUAL. 6.1. 6.1. TYPE L COPPER TO ASTM B88M. 13.7. CONTRACTOR SHALL REFER TO MANUFACTURER INSTALLATION REQUIREMENTS. HORIZONTAL OR VERTICAL INSTALLATION, ULC RATED (AS PER ENCLOSURE FIRE 6.2. JOINTS SHALL BE TIN/SILVER OR TIN/ANTIMONY (95%/5%) SOLDER AND NON-CORROSIVE RESISTANCE RATING). FLUX. ALL SOLDER SHALL BE LEAD FREE. 14. UNIT HEATER (UH-1) 6.2. FRD SHALL BE RUSKIN MODEL DIBD2 STYLE B (OR EQUAL FOR DUCT HEIGHTS NOT 6.3. PROVIDE ISOLATION VALVES FOR EACH NEW FIXTURE. VALVES SHALL BE BY PASS BALL 14.1. PROVIDE CAPACITIES AS INDICATED ON SCHEDULE. EXCEEDING 305mm, AND DIBD2 STYLE A (OR EQUAL) FOR DUCT HEIGHTS EXCEEDING VALVES WITH THREADED/SOLDERED ENDS, RATED FOR 400 CWP. 14.2. UNITS SHALL BE PROVIDED WITH SINGLE-POLE BUILT-IN THERMOSTAT KIT AND LOW 305mm. 6.4. TYPE K COPPER PIPE TO ASTM B88M SHALL BE USED FOR BURIED DCW PIPE. VOLTAGE RELAY. 6.3. PROVIDE ACCESS DOORS AT EACH FRD UNLESS FRONTAL ACCESS TO FRD IS AVAILABLE. 6.5. CONTRACTOR SHALL ENSURE THAT BACKFLOW PREVENTER IS INSTALLED AND PIPING ARE 14.3. POWER REQUIREMENTS: 115V/1PH/60HZ CLEARLY MARKED AS NON-POTABLE WATER. 14.4. FINISH: BEIGE 7. DIFFUSER/GRILLES/REGISTERS 14.5. CEILING MOUNTED (PER DRAWING) 7.1. TYPE A - SUPPLY GRILLE C/W DAMPER. EH PRICE / 520D/F/L/A. SIZE AS INDICATED ON 7. LARGE SANITARY AND VENT 14.6. UNIT HEATER SHALL BE PROVIDED COMPLETE WITH HORIZONTAL CONCENTRIC FLUE DRAWING. 7.1. SHALL BE MINIMUM 3" CAST IRON TO CAN/CSA-B70. VENTING KIT. 7.2. TYPE B - RETURN GRILLE C/W DAMPER. EH PRICE / 530D/F/L/A. SIZE AS INDICATED ON 7.2. JOINTS FOR CAST IRON SHALL BE HUB AND SPIGOT 14.7. UNIT HEATER SHALL BE SIMILAR TO LENNOX TUA OR APPROVED EQUAL. DRAWING. 14.8. CONTRACTOR SHALL REFER TO MANUFACTURER INSTALLATION REQUIREMENTS. 7.3. TYPE C - EXHAUST GRILLE C/W DAMPER. EH PRICE / 530D/F/L/A. SIZE AS INDICATED ON 8. VALVES (CW) DRAWING. 8.1. NEW VALVES UP TO 50MM (2 ) OR LESS SHALL BE BRASS OR BRONZE BALL VALVES WITH 15. CONTROLS 7.4. ALL DIFFUSER/GRILLE/REGISTER COLOURS SHALL BE CONFIRMED AT THE SHOP DRAWING (NPT)THREADED ENDS, FULL PORT, 1034KPA, (150PSIG) 600 WOG RATING. TFE SEATS, 15.1. CONTRACTOR SHALL PROVIDE A FULLY PROGRAMMABLE CONTROL (THERMOSTAT) PER STAGE WITH THE INTERIOR DESIGNER. DOUBLE O-RING DESIGN, OR TEFLON PACKING, CHROME PLATED SOLID BRONZE BALL, ULC ROOFTOP UNIT AND UNIT HEATER. EACH CONTROL SYSTEM SHALL BE COMPLETE WITH LISTED AND FM APPROVED. KITZ #58, TOYO #5044A MULTI-STAGE AND SIMULTANEOUS HEATING AND COOLING, OCCUPIED/UNOCCUPIED 8. THERMAL INSULATION FOR DUCTS 8.2. ALL VALVES 65MM,(2-1/2) OR GREATER,860KPA,(125PSIG)/200WOG RATING, SHALL HAVE OVERRIDE, TOUCHSCREEN LCD DISPLAY, 24/7 SCHEDULING, ECONOMIZER, FRESH AIR 8.1. BLANKET OR RIGID THERMAL INSULATION ON INDOOR DUCTS SHALL BE PROVIDED AND FLANGE CONNECTIONS. MOTORIZED ISOLATION DAMPER CONTROL, ETC... TO PROVIDE A COMPLETE AND INSTALLED AS FOLLOWS UNLESS OTHERWISE INDICATED: 8.3. ACCEPTABLE MANUFACTURER: KITZ, TOYO, AMERICAN VALVE OR APPROVED EQUAL. OPERATIONAL SYSTEM. 8.1.1. INSULATE FULL LENGTH OF FRESH AIR SUPPLY DUCTS. 15.2. PROVIDE ASSISTANCE TO GENERAL/MECHANICAL CONTRACTOR AS INDICATED IN THE 8.1.2. INSULATE FIRST 10FT OF EXHAUST DUCTS FROM EXTERIOR WALL OR ROOF. 9. BURIED SANITARY, STORM AND VENT TENDER DOCUMENTS. 8.1.3. INSULATE FULL LENGTH OF SUPPLY AND RETURN DUCTS THAT ARE ROUTED THROUGH A 9.1. SHALL BE MINIMUM 3" CAST IRON TO CAN/CSA-B70 OR PVC PLASTIC (XFR RATED). 15.3. ROOFTOP UNIT THERMOSTAT SHALL BE SIMILAR TO LENNOX - COMMERCIAL TOUCHSCREEN NON-CONDITIONED SPACE. 9.2. JOINTS SHALL BE HUB AND SPIGOT THERMOSTAT OR APPROVED EQUAL. 8.1.4. THERMAL INSULATION IS NOT REQUIRED ON SUPPLY AND RETURN DUCTS CONFINED 9.3. PROVIDE TRAP PRIMERS WHERE REQUIRED. WITHIN A CONDITIONED SPACE (INCLUDING RETURN PLENUM CEILINGS). 9.4. PROVIDE BACKWATER VALVE ON ALL FLOOR DRAINS AND WHERE INDICATED ON DRAWINGS. 8.1.5. ACOUSTICALLY LINED INTERIOR DUCTS NEED NOT TO BE THERMALLY INSULATED. 8.1.6. USE RIGID INSULATION AND DRYWALL TYPE CORNER BEADS IN AREAS WHERE 10. FLOW CONTROL ROOF DRAIN (RD) INSULATION IS EASILY SUSCEPTIBLE TO DAMAGE. 10.1. MIFAB SERIES R1100-F LACQUERED CAST IRON ROOF DRAIN WITH ANCHOR FLANGE, CAST 8.2. INSULATION SHALL BE FOIL FACED HAVING FLAME SPREAD RATING OF 25 OR LESS AND A IRON WATERPROOFING MEMBRANE CLAMP RING WITH INTEGRAL GRAVEL STOP, ACCUFLOW SMOKE DEVELOPMENT CLASSIFICATION OF 50 OR LESS. PARABOLIC WEIR (MAXIMUM FLOW OF 17.5GPM) F1 SLOTS, AND STANDARD SELF-LOCKING 8.3. THERMAL INSULATION SHALL BE 1-1/2" THICK BLANKET MINERAL FIBER OR 1" THICK RIGID POLYDOME STRAINER, WITH A FREE AREA OF 43 SQUARE INCHES. MINERAL FIBERBOARD FOR WARM AIR DUCTS AND DUCTS BETWEEN OUTSIDE WALLS AND 10.2. COORDINATE SELECTION WITH ROOF MEMBRANE. MIXING PLENUMS. 10.3. ROOF DRAIN SHALL BE MIFAB R1 100-F OR EQUAL. 8.4. THERMAL INSULATION FOR COLD AIR DUCTS SHALL BE 1-1/2" THICK RIGID INSULATION, OR 2" THICK BLANKET MINERAL FIBRE. 11. FLOOR DRAINS 8.5. VAPOUR-RETARDER MEMBRANE SHALL BE INSTALLED WITH INSULATION ON COLD, 11.1. CAST OR DUCTILE IRON SIZE AS INDICATED ON DRAWING. DUAL-TEMP AND FRESH AIR AIR SUPPLY DUCTS. 11.2. DRAIN SHALL BE ZURN OR EQUAL. 11.3. PROVIDE PRIMING AT EACH FLOOR DRAIN FROM NEAREST LAVATORY OR WATER CLOSET. 12. CLEAN-OUTS AND VENTING 12.1. PROVIDE IN ACCORDANCE WITH OBC CHAPTER 7 AND AS INDICATED ON DRAWINGS. 13. AUTOMATIC ELECTRONIC TRAP PRIMMER 13.1. (FLUSH) WALL MOUNTED NEMA 2 STAINLESS STEEL ENCLOSURE 13.2. FACTORY ASSEMBLED BRONZE BALL VALVE, WATER HAMMER ARRESTOR, SOLENOID VALVE, ATMOSPHERIC VACUUM BREAKER AND A TYPE l COPPER MANIFOLD C/W COMPRESSION FITTING. 13.3. ELECTRONIC SINGLE POINT POWER CONNECTION 120V 1AMP DRAW, MANUAL OVERRIDE SWITCH POINT POWER STEEL ACCESS PANEL. 13.4. ALL FLOOR DRAINs AND/OR DRY P-TRAPs SHALL BE PROVIDE WITH A PRIMING SYSTEM. 14. FIXTURES: 14.1. PROVIDE ALL NEW FIXTURES (AS INDICATED). 14.2. NEW FIXTURES SHALL BE BARRIER FREE AND CSA APPROVED. 14.3. FIXTURES SHALL MEET WATER EFFICIENCY REQUIREMENTS AS INDICATED IN OBC CHAPTER 7. 15. PROVIDE FIXTURES AS INDICATED BELOW: 15.1. CATCH BASIN/AREA DRAIN (CB-1) GAS PIPING: 1. PIPE 1.1. STEEL PIPE: TO ASTM A53, GRADE B, SCHEDULE 40, SEAMLESS AS FOLLOWS: 1.1.1. NPS 1/2 TO 2, SCREWED. 1.1.2. NPS 2 1/2 AND OVER, PLAIN END. 1.1.3. COPPER TUBE: TO ASTM B75M. 1.2. JOINING MATERIAL 1.2.1. SCREWED FITTINGS: PULVERIZED LEAD PASTE. 1.2.2. WELDED FITTINGS: TO CSA W47.1. 1.2.3. FLANGE GASKETS: NONMETALLIC FLAT. 1.2.4. SOLDERED: TO ASTM B32, TIN ANTIMONY 5/5. 2. FITTINGS 2.1. STEEL PIPE FITTINGS, SCREWED, FLANGED OR WELDED: 2.1.1. MALLEABLE IRON: SCREWED, BANDED, CLASS 150. 2.1.2. STEEL PIPE FLANGES AND FLANGED FITTINGS: TO ANSI/ASME B16.5. 2.1.3. WELDING: BUTT-WELDING FITTINGS. 2.1.4. UNIONS: MALLEABLE IRON, BRASS TO IRON, GROUND SEAT, TO ASTM A47M. 2.1.5. BOLTS AND NUTS: TO ANSI B18.2.1. 2.1.6. NIPPLES: SCHEDULE 40, TO ASTM A53. 2.2. COPPER PIPE FITTINGS, SCREWED, FLANGED OR SOLDERED: 2.2.1. CAST COPPER FITTINGS: TO ANSI B16.18. 2.2.2. WROUGHT COPPER FITTINGS: TO ANSI/ASME B16.22. 3. VALVES 3.1. PROVINCIAL CODE APPROVED, LUBRICATED PLUG TYPE. 4. INSTALLATION 4.1. INSTALL IN ACCORDANCE WITH APPLICABLE PROVINCIAL CODES. 4.2. INSTALL IN ACCORDANCE WITH CAN/CGA B149.1. 4.3. ASSEMBLE PIPING USING FITTINGS MANUFACTURED TO ANSI STANDARDS. 4.4. CONNECT TO EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTION UNLESS OTHERWISE INDICATED. 4.5. SLOPE PIPING DOWN IN DIRECTION OF FLOW TO LOW POINTS. 4.6. INSTALL DRIP POINTS: 4.6.1. AT LOW POINTS IN PIPING SYSTEM. 4.6.2. AT EACH CONNECTION TO EQUIPMENT. 4.7. 4.8. 4.9. 4.10. 4.11. 4.12. 4.13. USE ECCENTRIC REDUCERS AT PIPE SIZE CHANGE INSTALLED TO PROVIDE POSITIVE DRAINAGE. PROVIDE CLEARANCE FOR ACCESS AND FOR MAINTENANCE. REAM PIPES, CLEAN SCALE AND DIRT, INSIDE AND OUT. INSTALL PIPING TO MINIMIZE PIPE DISMANTLING FOR EQUIPMENT REMOVAL. INSTALL VALVES WITH STEMS UPRIGHT OR HORIZONTAL UNLESS OTHERWISE APPROVED BY ENGINEER. INSTALL VALVES AT BRANCH TAKE-OFFS TO ISOLATE EACH PIECE OF EQUIPMENT, AND AS INDICATED. CONTRACTOR SHALL APPLY YELLOW PAINT TO ALL GAS PIPING. 5. TESTING 5.1. TEST SYSTEM IN ACCORDANCE WITH CAN/CGA B149.1 AND REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. 5.2. PURGE AFTER PRESSURE TEST IN ACCORDANCE WITH CAN/CGA B149.1 HANGERS ROD. 610 FRAME & COVER SECURED IN CONCRETE HEAVY DUTY CLEVIS HANGER METAL FRAME & COVER F.F.EL: 249.15 EXTENSION COLLAR AS REQUIRED BUILDING OVERHANG SUPPORT & LOCK NUTS TANK TOP VENTS TO BE CONNECTED TO VENTING SYSTEM 300 UNION FLOW CONTROL VALVE 100 INLET UNION BACK WATER VALVE 100 OUTLET FIBERGLASS INSULATION MIN. 50mm THICK ADJACENT BUILDING FLASHING 50mm CLEARANCE THIMBLE 200 APPROVED VENT CAP 711 16GA. GALV. SADDLE HANGER ROD SIZES UP TO 50mm 64mm - 75mm 100mm - 125mm FLUE VENT 1830 MIN. 813mm (W) x 1575mm (L) x 711mm (H) 305 MIN. 250mm INSULATION AS SPECIFIED PIPE SIZE PROCEPTOR 400 MIN. PITCH FLUE PIPE DOWN TOWARD OUTLET 1/4" PER FOOT OF RUN TO ALLOW FOR CONDENSATE DRAINAGE MIN. 6" PEA GRAVEL BED (OR APPROVED BACKFILL COMPACTED TO 98% SPD) 150mm - 300mm 1575 HANGER ROD DIAMETER 10mm 13mm 16mm 22mm 2032 HANGER SPACING PIPE SIZE 25mm 30mm 40mm 50mm 65mm 75mm 100mm 125mm 150mm 200mm 250mm 300mm MAXIMUM 2100 SPACING 2400 2700 3000 3300 3600 4200 4800 5100 5700 6600 CAST-IN-PLACE ANTI-BUOYANCY SLAB FOR HIGH WATER TABLE CONDITIONS. 3000PSI CONCRETE READY MIX. POUR AROUND BASE OF UNIT (16 CU. FT. MINIMUM - BASED ON CONCRETE DENSITY OF 130 LBS/CU. FT.) NOTES: 1. PEA GRAVEL TO 3FT HORIZONTALLY AROUND TANK (OR APPROVED EQUIVALENT COMPACTED TO 98% SPD). 2. METAL FRAME AND COVER TO BE RATED FOR VEHICLE TRAFFIC LOADING CONDITIONS. 6900 FLOOR SLAB SEALANT BACKER ROD & SEALANT DUCT OR PIPE STRAINER BODY REMOVABLE STAINLESS STEEL STRAINER 13 RIGID FIBREGLASS INSULATION FINISHED FLOOR LINE SLOPE 200 MIN. (TYPICAL) CLEANOUT COVER FRAME FINISHED FLOOR LINE BRASS SCREW PLUG SLOPE SHEET METAL SLEEVE (SCHEDULE 10 STEEL) WALL (TYPE VARIES - FOR CAVITY WALL USE SPLIT SLEEVE) SEALANT. CONNECT TO STUD WITH "L" BRACKET IF NECESSARY (BOTH SIDES) C.I. CONNECTOR SUITE DRAIN & P-TRAP SIZE FERRULE DUCT (LONG SWEEP) PVC P-TRAP SLEEVE TO MAIN LINE (SIZE INDICATED IN PLAN) CLEANING EYE GASKET BY MECH. CONTRACTOR MECHANICAL EQUIPMENT TOP OF WOOD BLOCKING TO BE LEVEL. USE UNTREATED WOOD SOLID ROD TIE BAR TO CONNECT STRAIGHT PIPE TO ELBOW ONLY. CONNECTING FROM STRAIGHT PIPE TO STRAIGHT PIPE IS NOT ACCEPTABLE. PRE-FIN. METAL FLASHING EXISTING GOOSE NECK EXHAUST DUCT. BIRDSCREEN AND BURGLAR BARS FILL VOID IN DUCT TO ROOF LINE WITH MINERAL WOOL INSULATION SOLID ROD TIE BAR (TYPICAL) TYPICAL ROOF CONSTRUCTION 254mm BUILD PARTITION AROUND AND CAULK WATER-PROOFING (FOR TOILETS) ATTACH BASE ELBOW TO ANCHOR TO ADJACENT STRUCTURE BRACING AT 90 DEG. ELBOW STEEL DECK ROOF RISER CLAMP (TYPICAL) VAPOUR BARRIER BARS AND STEEL PLATE FRAME TO BE SUPPLIED BY MISCELLANEOUS METAL CONTRACTOR AND INSTALLED BY MECH. CONTRACTOR PRIMED 3mm THICK BENT STEEL PLATE WELDED TO STEEL DECK. CHECK EQUIPMENT SPECS. BRACING AT 45 DEG. ELBOW CLEANOUT PLUG ROOF OPENING SUPPORT - SEE STRUCTURAL DRAWINGS BRACING AT CLEANOUT JOINT COUPLING (TYPICAL) BRACING AT LINE JOINT CL INSTALL ROOF DRAIN AS PER MANUFACTURER'S RECOMMENDATIONS AND ARCA STANDARDS STAINLESS STEEL GRAVEL STOP, TIE TO DOME WITH PLASTIC TIE. ANGLE AT JOIST PANEL POINT SEAL ROOF MEMBRANE TO DRAIN FLANGE ALL AROUND OPENING ROOF MEMBRANE HANGER ROD GAS LINE VIBRATION ISOLATORS (4) CONCENTRIC AIR VENT SHUT OFF GAS COCK ROOF DECK ROOF INSULATION TAPERED TO DRAIN (600 DIAMETER) UNDER DECK CLAMP DIRT POCKET INSULATE PIPE AND DRAIN PAN GASKETS UNION RIGID CONDUIT SENSOR OR THERMOSTAT PER SCHEDULE. LOCKING METAL GUARD OVER THERMOSTAT. NOTE: SUPPORT UNIT AS INSTRUCTED BY MANUFACTURER, ALLOW FOR CONCRETE DECK, STEEL BEAM AND JOIST. INSTALL AT LOCATION INDICATED ON THE PLAN WATERTIGHT NEOPRENE GASKET NOTES: NOTES: CURBS AND FANS SHALL BE FROM SAME MANUFACTURER. ALUMINUM VENT CONE URETHANE FOAM INSULATION VENT PIPE EXTENDER DETAIL FOR REFERENCE ONLY. SPECIFIED UNIT MAY HAVE DIFFERENT DUCT ARRANGEMENT. VERIFY WITH UNIT SHOP DRAWINGS. SPUN ALUMINUM HOUSING VIBRATION ELIMINATORS MINIMUM 200mm HIGH FLASHING AND COUNTERFLASHING GAS SUPPLY FUSED DISCONNECT SWITCH SUPPLIED BY DIV. 16 ALUMINUM BIRDSCREEN SECURE FAN TO CURB W/ S.M. SCREWS 300 OC ALL AROUND SPUN ALUMINUM COMPONENTS FOAM RUBBER GASKET TO UNDERSIDE OF FAN CURB CAP ROOF STRUCTURE BACK DRAFT DAMPER OR MOTORIZED DAMPER DUCT EXTENSION WITH WIRE MESH SCREEN COVERING OPENING 25mm PIPE INSULATION. MINIMUM 5' FROM ROOF SUPPLY AIR DUCT RETURN AIR DUCT ROOF CURB P TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT CIRCULATING PUMP BV TO SYSTEM (SEE DRAWINGS FOR CONTINUATION) CONDENSATE TRAP AND DRAIN DHWR DHW SLIP-FIT CLEAN-OUT PLUG DCW T 3 REMOTE READOUT AHU SLIP-FIT CLEAN-OUT PLUG WITH 6 mm ~ VENT HOLE 1 WATTS, MODEL: 50-007-QT. UPON INSTALLATION IT SHALL BE REGISTERED WITH LOCAL UTILITY COMPANY. NC 2 NO NO EXP-1 REFERENCE NOTES: 3 M FLOOR DCW LINE. MUNICIPALITY STANDARDS C/W REMOTE READ-OUT. T&P RV 50mm MIN. BFP DIELECTRIC UNION (TYP.) PROVIDE NEW DOMESTIC HOT WATER HEATER C/W, THERMOMETER, RELATED ACCESSORIES AND PIPING. REFER TO EQUIPMENT SCHEDULE FOR MORE INFO. DRAIN LINE - SEE PLANS FOR SIZE. PROVIDE NEW 100MM CONCRETE HOUSEKEEPING PAD. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFO. HWT NEW THERMAL EXPANSION TANK (EXP-1) TO BE INSTALLED ON DOMESTIC COLD WATER PIPING SERVING DOMESTIC HOT WATER TANKS DIELECTRIC UNION (TYP.) FF 2 1 TRAP EQUAL TO AHU EXTERNAL STATIC PRESSURE ROOF TOP UNIT SCHEDULE MANUFACTURER BASE UNIT NOMINAL & MODEL WEIGHT CAPACITY ( OR APPROVED (kg) (TONS) EQUAL) TAG RTU-1 (15-TONS) - DOMESTIC WATTS EXP-1 HOT WATER MODEL DRY TANK QTY WEIGHT VOLUME (kg) (L) DETA 5 10 1 103 66 420 - RTU-5 (3-TONS) MANUF. 498 - RTU-4 (7.5 TONS) SYSTEM INPUT (kW) 15 626 - RTU-3 (10-TONS) TAG HEATING OUTPUT (kW) 82 NET TOTAL (kW) MINIMUM OUTDOOR AIR FLOW (L/S) SUPPLY FAN COOLING NET SENSIBLE (kW) 54.5 39.75 FLOW (L/S) E.S.P. (PA) 2832 FAN MOTOR (hp) 250 ELECTRICAL REMARKS FLA (A) - 3.6 MCA (A) MOCP (A) 33.0 - 40 7.5 498 - 10 229 3 53 66 34 54 43 54 27 35.6 26.93 27.6 21.04 35.6 26.93 11.26 8.73 1888 250 1416 250 1888 250 566 250 - 3.6 3.6 - - - 3.6 - - 3.6 20.0 - 25 13.0 15 18.0 20 7.0 - 15 BP-1 BP-2 BP-3 BP-4 BP-5 BP-6 BP-7 BP-8 EH PRICE EH PRICE EH PRICE EH PRICE EH PRICE EH PRICE EH PRICE EH PRICE MODEL 7.5 53 43 27.6 21.04 1416 250 3.6 - - 13.0 15 575/3/60 RTU-7 (7.5 TONS) - 420 7.5 53 43 27.6 21.04 1416 250 3.6 - - 13.0 15 575/3/60 LGB - 6 -- -- 170 AS SHOWN ON DRAWING LGB - 6 -- 205 AS SHOWN ON DRAWING LGB - 6 -- 213 -- 170 AS SHOWN ON DRAWING -- 86 NOTES BASIS OF DESIGN - C/W ELECTRONIC MODULATING CONTROLS, TRANSFORMERS, THERMOSTATS AND ALL ASSOCIATED CONTROL WIRE. - C/W ELECTRONIC MODULATING CONTROLS, TRANSFORMERS, THERMOSTATS AND ALL ASSOCIATED CONTROL WIRE. - C/W ELECTRONIC MODULATING CONTROLS, TRANSFORMERS, THERMOSTATS AND ALL ASSOCIATED CONTROL WIRE. - C/W ELECTRONIC MODULATING CONTROLS, TRANSFORMERS, THERMOSTATS AND ALL ASSOCIATED CONTROL WIRE. - C/W ELECTRONIC MODULATING CONTROLS, TRANSFORMERS, THERMOSTATS AND ALL ASSOCIATED CONTROL WIRE. - C/W ELECTRONIC MODULATING CONTROLS, TRANSFORMERS, THERMOSTATS AND ALL ASSOCIATED CONTROL WIRE. - C/W ELECTRONIC MODULATING CONTROLS, TRANSFORMERS, THERMOSTATS AND ALL ASSOCIATED CONTROL WIRE. - C/W ELECTRONIC MODULATING CONTROLS, TRANSFORMERS, THERMOSTATS AND ALL ASSOCIATED CONTROL WIRE. -- 171 AS SHOWN ON DRAWING EXHAUST FAN SCHEDULE AIR FLOW MIN. (L/S) 95 AS SHOWN ON DRAWING LGB - 8 -- OIL INTERCEPTOR TAG LOCATION MANUFACTURER MODEL FLOW RATE (L/S) INT-1 SERVICE DEPARTMENT 123 PROCEPTOR BY GREENTURTLE OMC-150 - INLET / OUTLET (mm) LXWXH (mm) 100 1575 x 813 x 915 TAG LOCATION EF-1 WEIGHT (kg) FLOW (L/s) STATIC PRESSURE (Pa) * C/W EPOXY COATED NON-SKID BODY COVER, FABRICATED STEEL BODY AND NO HUB CONNECTIONS MANUFACTURER MODEL OVERALL WIDTH (mm) NOZZLE WIDTH (mm) MOUNTING WIDTH (mm) OHAC-1 VESTIBULE 100 POWERED AIRE CED 1-60E 1549.4 1524 1526 WASHROOM - WC 1 107 GREENHECK SP-A110 8 42 62.3 950 51 WATTS CEILING MOUNTED FAN C/W BACKDRAFT DAMPER, HANGING HARDWARE C/W WALL SWITCH EF-2 WASHROOM - WC 2 108 GREENHECK SP-A110 8 42 62.3 950 51 WATTS CEILING MOUNTED FAN C/W BACKDRAFT DAMPER, HANGING HARDWARE C/W WALL SWITCH EF-3 TECH. WC 120 GREENHECK SP-A110 8 42 62.3 950 51 WATTS CEILING MOUNTED FAN C/W BACKDRAFT DAMPER, HANGING HARDWARE C/W WALL SWITCH EF-4 WC - 203 GREENHECK SP-A110 8 42 62.3 950 51 WATTS CEILING MOUNTED FAN C/W BACKDRAFT DAMPER, HANGING HARDWARE C/W H-O-A STARTER AND 24/7 TIMER EF-5 WC - 204 GREENHECK SP-A110 8 42 62.3 950 51 WATTS CEILING MOUNTED FAN C/W BACKDRAFT DAMPER, HANGING HARDWARE C/W WALL SWITCH EF-6 ON ROOF ABOVE SERVICE PART WASHROOM GREENHECK GB-091 28 260 62.3 1000 187 ROOF MOUNTED CENTRIFUGAL EXHAUST FAN, GRAVITY BACK DRAFT DAMPER, ROOF CURB, AND ALUMINUM BIRD SCREEN C/W H-O-A STARTER AND REVERSE ACTING THERMOSTAT EF-7 ON ROOF GREENHECK USGF-180 86.2 2217 31 1275 1-1/2 ROOF MOUNTED CENTRIFUGAL EXHAUST FAN, GRAVITY BACK DRAFT DAMPER, ROOF CURB, AND ALUMINUM BIRD SCREEN C/W H-O-A STARTER AND REVERSE ACTING THERMOSTAT EF-8 ON ROOF GREENHECK USGF-180 86.2 2217 31 1275 1-1/2 ROOF MOUNTED CENTRIFUGAL EXHAUST FAN, GRAVITY BACK DRAFT DAMPER, ROOF CURB, AND ALUMINUM BIRD SCREEN C/W H-O-A STARTER AND REVERSE ACTING THERMOSTAT EF-9 ON LOW ROOF GREENHECK USGF-140 56.7 994 31 1210 1/3 ROOF MOUNTED CENTRIFUGAL EXHAUST FAN, GRAVITY BACK DRAFT DAMPER, ROOF CURB, AND ALUMINUM BIRD SCREEN C/W H-O-A STARTER AND REVERSE ACTING THERMOSTAT EF-10 ON ROOF BY OTHERS EF-11 ELECTRICAL ROOM 122 GREENHECK - - 142 31 - - CEILING MOUNTED FAN C/W BACKDRAFT DAMPER, HANGING HARDWARE C/W H-O-A STARTER AND 24/7 TIMER EF-12 MECHANICAL ROOM 123 GREENHECK - - 142 31 - - CEILING MOUNTED FAN C/W BACKDRAFT DAMPER, HANGING HARDWARE C/W H-O-A STARTER AND 24/7 TIMER EF-13 IT 205 BROAN S50U 4.5 23.6 25 820 51 WATTS CEILING MOUNTED FAN C/W BACKDRAFT DAMPER, HANGING HARDWARE C/W WALL SWITCH INSTALLATION SPECIFICATIONS DONE BY OTHERS. CONTRACTOR TO INSTALL UNITS AS PER MANUFACTURER'S INSTRUCTION. ALL ROOF MOUNTED FANS SHALL BE INSTALLED ON ROOF CURB, SUPPLIED WITH FAN; SEE DETAIL 14/M.1.3. NOTES * PROVIDE UNIT MOUNTED THERMOSTAT AND UNIT MOUNTED DISCONNECT SWITCH. TAG LOCATION MANUFACTURER MODEL QTY DRY WEIGHT (kg) CAPACITY (Liters) RECOVERY RATE (L/S) TEMPERATURE RISE HWT-1 MECHANICAL ROOM 123 AO SMITH BTH-120(A) Mxi 1 220 227 0.15 56 UH-1 MANUFACTURER LENNOX MODEL LF24-100A QTY 3 64 INPUT 29.3 23.6 3657.6 VOLTAGE 115/1/60 FLUE DIAMETER (mm) ELECTRICAL (V/Hz) REMARKS FLOOR MOUNTED ON PAD C/W VENT KIT AND CONDENSATE KIT 120/60 MAKE UP AIR UNIT SCHEDULE UNIT HEATER SCHEDULE MIN MOUNTING HEIGHT OUTPUT (mm) REMARKS HOT WATER HEATER SCHEDULE LOCATION GAS HEATING CAPACITY (kW) MOTOR MODEL NOTES TAG WEIGHT (kg) FAN RPM MANUFACTURER OVERHEAD AIR CURTAIN DOOR TAG REFRIGERANT: 410A UNIT TO BE COMPLETE WITH ROOF CURB (14"), POWER EXHAUST, HAIL GUARD, CONDENSATE TRAP, CONTROL INTERFACE. S.S. HEAT EXCHANGER. COMPLETE WITH CONTROLLER OF SAME MANUFACTURER OF UNIT: 'RTAM MODULE FOR VAV SYSTEMS'. UNIT SHALL BE COMPLIANT WITH ASHREA 90.1-2010 BALANCE OUTSIDE AIR TO 600 CFM (283 L/S) GAS BURNER SHALL BE FULLY MODULATED. S.S. HEAT EXCHANGER. REFRIGERANT: 410A UNIT TO BE COMPLETE WITH ROOF CURB (14"), POWER EXHAUST, HAIL GUARD, CONDENSATE TRAP, CONTROL INTERFACE. S.S. HEAT EXCHANGER. COMPLETE WITH CONTROLLER OF SAME MANUFACTURER OF UNIT: 'RTAM MODULE FOR VAV SYSTEMS'. UNIT SHALL BE COMPLIANT WITH ASHREA 90.1-2010 BALANCE OUTSIDE AIR TO 600 CFM (283 L/S) GAS BURNER SHALL BE FULLY MODULATED. S.S. HEAT EXCHANGER. PROVIDE ALL SENSORS AND ACCESSORIES FOR A FULLY FUNCTIONAL CONTROL SYSTEM. CONTRACTOR TO INCLUDE TWO (2) DAYS FOR UNIT MANUFACTURER SETUP AND START UP OF SYSTEM AND CONTROLS. CONTRACTOR TO INSTALL UNITS AS PER MANUFACTURER'S INSTRUCTION. ALL CONTROL CONNECTIONS AND SETUP SHALL BE AS PER MANUFACTURER'S INSTRUCTION. 170 AS SHOWN ON DRAWING LGB - 8 575/3/60 REFRIGERANT: 410A UNIT TO BE COMPLETE WITH ROOF CURB (14"), HUMIDITY CONTROL SYSTEM, HAIL GUARD, CONDENSATE TRAP, CONTROL INTERFACE. S.S. HEAT EXCHANGER. COMPLETE WITH CONTROLLER OF SAME MANUFACTURER OF UNIT. TO BE COMPLETE WITH MICROMETL DIFFUSER: CNKT-543C-**FX; DIFFUSER SHALL BE HEAVY GAUGE, SUITABLE FOR GYM USE. UNIT SHALL BE COMPLIANT WITH ASHREA 90.1-2010 BALANCE OUTSIDE AIR TO 300 CFM (142 L/S) GAS BURNER SHALL BE FULLY MODULATED. S.S. HEAT EXCHANGER. 420 AIR FLOW MAX. (L/S) AS SHOWN ON DRAWING LGB - 6 575/3/60 REFRIGERANT: 410A UNIT TO BE COMPLETE WITH ROOF CURB (14"), POWER EXHAUST, HAIL GUARD, CONDENSATE TRAP, CONTROL INTERFACE. S.S. HEAT EXCHANGER. COMPLETE WITH CONTROLLER OF SAME MANUFACTURER OF UNIT: 'RTAM MODULE FOR VAV SYSTEMS'. UNIT SHALL BE COMPLIANT WITH ASHREA 90.1-2010 BALANCE OUTSIDE AIR TO 1000 CFM (472 L/S) GAS BURNER SHALL BE FULLY MODULATED. S.S. HEAT EXCHANGER. 13.3 AS SHOWN ON DRAWING LGB - 6 575/3/60 REFRIGERANT: 410A UNIT TO BE COMPLETE WITH ROOF CURB (14"), POWER EXHAUST, HAIL GUARD, CONDENSATE TRAP, CONTROL INTERFACE. S.S. HEAT EXCHANGER. COMPLETE WITH CONTROLLER OF SAME MANUFACTURER OF UNIT: 'RTAM MODULE FOR VAV SYSTEMS'. UNIT SHALL BE COMPLIANT WITH ASHREA 90.1-2010 BALANCE OUTSIDE AIR TO 600 CFM (283 L/S) GAS BURNER SHALL BE FULLY MODULATED. S.S. HEAT EXCHANGER. REMARKS LOCATION LGB - 6 REFRIGERANT: 410A UNIT TO BE COMPLETE WITH ROOF CURB (14"), POWER EXHAUST, HAIL GUARD, CONDENSATE TRAP, CONTROL INTERFACE. COMPLETE WITH CONTROLLER OF SAME MANUFACTURER OF UNIT: 'RTAM MODULE FOR VAV SYSTEMS'. UNIT SHALL BE COMPLIANT WITH ASHREA 90.1-2010 BALANCE OUTSIDE AIR TO 250 CFM (118 L/S) GAS BURNER SHALL BE FULLY MODULATED. S.S. HEAT EXCHANGER. 575/3/60 - BYPASS BOX - SCHEDULE MANUFACTURER REFRIGERANT: 410A UNIT TO BE COMPLETE WITH ROOF CURB (14"), POWER EXHAUST, HAIL GUARD, CONDENSATE TRAP, CONTROL INTERFACE. COMPLETE WITH CONTROLLER OF SAME MANUFACTURER OF UNIT: 'RTAM MODULE FOR VAV SYSTEMS'. UNIT SHALL BE COMPLIANT WITH ASHREA 90.1-2010 BALANCE OUTSIDE AIR TO 300 CFM (142 L/S) GAS BURNER SHALL BE FULLY MODULATED. S.S. HEAT EXCHANGER. 575/3/60 RTU-6 (7.5 TONS) INSTALL PER MANUFACTURER RECOMMENDATION. CHARGE TANK TO THE DOMESTIC WATER PRESSURE PRIOR TO CONNECTION; 100 PSI RELIEF VALVE ON WATER HEATER TAG VOLTAGE (V/ /HZ) 10 RTU-2 (10-TONS) EXPANSION TANK SCHEDULE CAPACITY AIR FLOW (L/S) UNIT DIMENSIONS (LxWxH) (mm) 897 996 x 513 x 818 SUPPLY FAN REMARKS GAS FIRED UNIT HEATER C/W VERTICAL FLUE VENTING KIT UNIT TO BE C/W HANGING BRACKETS KIT & THERMOSTAT. GAS HEATING TAG LOCATION MANUFACTURER MODEL AIR (L/S) ESP "WC (PA) TSP "WC (PA) MIN. O/A (l/s) FUEL TYPE (kW) OUTPUT MUA-1 ON ROOF REZNOR RPBL-400 1888 125 500 - NG 95.2 ELECT. SERVICE MOTOR (HP) WEIGHT (kg) V/PH/Hz 1 552 575/3/60 NOTES 1. PLUMBING FIXTURE SCHEDULE OPERATION PARAMETERS 1.1. PROVIDING CONTINUOUS MONITORING IN AMBIENT AIR AND TWO FACTORY-SET ALARM LEVELS AND OUTPUTS. PIPE SIZES (mm) TAG FIRST ALARM (TWA) SECOND ALARM (STEL) SENSOR LOCATION CARBON MONOXIDE (CO) 25 PPM 100 PPM 800 - 1200MM ABOVE THE FLOOR AS PER OBC NITROGEN DIOXIDE (NO ) 0.72 PPM 2 PPM 300MM BELOW THE CEILING AS PER OBC -- AMERICAN STANDARD CADET PRESSURE-ASSISTED ELONGATED #2462.016.020 LOW CONSUMPTION TOILET, 381 MM HIGH, WHITE VITREOUS CHINA WITH EVERCLEAN ANTIMICROBIAL SURFACE WHICH INHIBITS THE GROWTH OF STAIN AND ODOR CAUSING BACTERIA MOLD AND MILDEW, FLOOR MOUNTED, SIPHON JET FLUSH ACTION, 6 L (1.6 US GAL) PER FLUSH, RAISED SANITARY BAR, 305 MM X 254 MM (12" X 10") WATER SURFACE AREA, TWO PIECE, 'SPEED CONNECT' TANK ASSEMBLY, UNBOLTED TANK COVER, 305 MM (12") ROUGH-IN, ELONGATED BOWL, 54 MM (2-1/8") FULLY GLAZED INTERNAL TRAPWAY, FLOOR OUTLET, BOLT CAPS. CENTOCO #500STSCC.001 TOILET SEAT, HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, LESS COVER, REINFORCED STAINLESS STEEL WC (203), WC (204), TECH. WM'S CHECK HINGES, METAL FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. MCGUIRE #LFH166LKN3, TOILET SUPPLY, CHROME PLATED POLISHED BRASS, HEAVY DUTY ANGLE STOPS, 13 MM (1/2") I.P.S. WC (134), INLET X 76 MM (3") LONG RIGID HORIZONTAL NIPPLES, V.P. LOOSE KEYS, ESCUTCHEON AND FLEXIBLE COPPER RISER. PROVIDE FLOOR FLANGE, (SAME MATERIAL AS THE CONNECTING PIPE DRAIN), WITH ALL TECH. MEN'S WC (131) BRASS BOLTS AND WITH RUBBER GASKET. -- WC-1 GROUND FLOOR TECH. WC 121, WC1 (107), WC2 (108) LOW-LEVEL ALARM SIGNAL IS SENT FROM RELAY OUT TO FAN STARTER AND DAMPER CONTROL. LOW ALARM INDICATORS LIGHT FOR POINT IN ALARM UNTIL HAZARDOUS GAS CONCENTRATION LEVELS ARE REDUCED TO BELOW SET POINT ALARM LEVELS WALL HUNG BASIN SINGLE LEVER FAUCET HIGH LEVEL ALARM L-1 TECH. MEN'S WC (131), TECH. WC 121, WC1 (107), WC2 (108), DIESEL ENGINE EMISSIONS ( NITROGEN DIOXIDE ) LOW LEVEL ALARM IF THE NO2 REMOTE SENSOR DETECTS A .72 PPM CONCENTRATION OF GAS THE FAN STARTER SHOULD BE ACTIVATED THROUGH THE SAME RELAY AS WELL AS ANY DAMPERS. HIGH LEVEL ALARM 2. L-2 GAS MONITORING TRANSMITTERS: HONEYWELL ANALYTICS E3SM-E3SCO & E3SM-E3NO2 2.1 2.2 THE TRANSMITTER WILL BE CAPABLE OF SENDING SIGNAL THROUGH A MODBUS OUTPUT OR AN ONBOARD DPDT RELAYS (5A, 30 VDC OR 250 VAC (RESISTIVE LOAD)) WILL BE ACTIVATED AT PROGRAMMABLE SET POINTS. AN LCD DISPLAY WILL PROVIDE LOCAL GAS CONCENTRATION READINGS. 2.4 U-1 WALL HUNG URINAL FOR FLUSHOMETER EXPOSED MANUAL TRANSMITTER WILL BE CAPABLE OF OPERATING WITHIN RELATIVE HUMIDITY RANGES OF 5-95% ELECTROCHEMICAL SENSOR FOR CARBON MONOXIDE AND NITROGEN DIOXIDE. TO BE CALIBRATED SEMI-ANNUALLY AS PER MANUFACTURER'S INSTRUCTIONS. SENSOR SHALL HAVE A CONTINUOUS SELF-TEST FOR SENSOR CELL LIFE VALIDATION OF OPERATION SIMILAR TO HONEYWELL REFLEX TECHNOLOGY. 2.5 LED INDICATOR LIGHTS FOR POWER, ALARM 1 AND ALARM 2 LEVELS. FOR LOCAL ACTIVATION OF AUDIBLE ALARMS, THE TRANSMITTER SHALL HAVE AN ON-BOARD DEVICE ABLE TO GENERATE AN AUDIBLE OUTPUT OF 85 DBA @ 10 FT (3M). INDOOR REMOTE MOUNTED STROBE TO BE PROVIDED WITH WHITE CANDELA. 2.6 TRANSMITTER IN CAR WASH BAY TO INCLUDE AN ECLAB WATERPROOF ENCLOSURE. 3. CONTROL PANEL: VA301C 3.1 3.2 S-1 3.3 THE CONTROLLER MUST INCLUDE A SELF-TEST FUNCTION THAT ALLOWS FOR THE ACTIVATION/DEACTIVATION OF ALL THE PROGRAMMED OUTPUTS BY SIMULATING A CONTINUOUS 5% INCREASE/DECREASE VALUE UNTIL THE MAXIMUM/MINIMUM VALUE IS REACHED. 3.4 THE CONTROLLER MUST INCLUDE A REAL-TIME CLOCK THAT ENABLES OPERATION OF THE OUTPUTS FOR A SPECIFIC TIMEFRAME. 3.5 THE CONTROLLER MUST ALSO INCLUDE AN ENERGY SAVING FEATURE THAT ALLOWS FOR OUTPUT OPERATION ON ALARMS SET AT THE MAX, MIN OR AVERAGE VALUE OF A SPECIFIC GROUP OF TRANSMITTERS. THIS FEATURE MUST ALSO ALLOW FOR THE ACTIVATION OF OUTPUTS UPON A CERTAIN COUNTERTOP MOUNT SINK SINGLE LEVER FAUCET TOOL ROOM (120) S-2 COUNTERTOP MOUNT SINK SINGLE LEVER FAUCET LUNCH ROOM (130) THE CONTROL PANEL MUST BE CAPABLE OF COMMUNICATING DIGITALLY WITH THE NETWORKED TRANSMITTERS AND RELAY MODULES THROUGH THREE RS-485 MODBUS COMMUNICATION BUSES. EACH COMMUNICATION BUS MUST BE CAPABLE OF ACCEPTING A COMBINATION OF UP TO 32 ADDRESSABLE TRANSMITTERS, RELAY MODULES, OR ANNUNCIATOR PANELS AT A MAXIMUM DISTANCE OF 2,000 FEET. THE POWER SUPPLY SHALL BE OF EITHER 24 VAC OR 24 VDC THE CONTROLLER WILL MANAGE FOUR INTERNAL DPDT RELAYS AT FULLY PROGRAMMABLE ALARM LEVELS (AND WITHIN PROGRAMMABLE TIME DELAYS) AND BE CAPABLE OF ACTIVATING MULTIPLE RELAY MODULES OF EIGHT RELAYS EACH. THE RELAY RATING WILL BE NO LOWER THAN 5 A, 30 VDC OR 250 VAC (RESISTIVE LOAD). VENT SH-1 SHOWER FLOOR SHOWER VALVE AND HEAD TECH MEN'S WC (131) MS-1 AMERICAN STANDARD MURRO WITH EVERCLEAN #0954.004EC/0059.020EC BASIN, 540 MM X 520 MM X (21-1/4" X 20-1/2" X 6-1/2") DEEP, VITREOUS CHINA, FOR CARRIER WITH CONCEALED ARMS, REAR OVERFLOW, RECESSED SELF-DRAINING FAUCET LEDGE, SEMI-PEDESTAL P-TRAP COVER. . CHICAGO FAUCETS #420-ABCP SINGLE LEVER FAUCET, CHROME PLATED, 4" (102MM) CENTERSET, LEAD FREE CAST BRASS BODY, CERAMIC 1/4 TURN CARTRIDGE, 5.7 LPM (1.5 GPM) NON-AERATING LAMINAR OUTLET, 131 MM (5-3/16") PROJECTION REACH, LEVER HANDLE, VOLUME CONTROL, ADJUSTABLE HOT LIMIT STOP. LAWLER #TMM-1070, POINT OF USE MECHANICAL WATER MIXING VALVE, BRONZE BODY, TEMPERATURE ADJUSTING DIAL, 10 MM (3/8") INLETS AND OUTLET COMPRESSION FITTINGS, HIGH TEMPERATURE THERMOSTATIC LIMIT STOP (AUTOMATIC SHUTS DOWN FLOW OF WATER WHEN TEMPERATURE REACHES 48 DEG.C (118 DEG.F) WITH AUTOMATIC RESET, SHUT-OFF WITH AUTOMATIC RESET WHEN TEMPERATURE EXCEEDS 120F (48.8C), INTEGRAL CHECKS, OFFER TEMPERATURE RANGE FROM FULL COLD THROUGH 46 (114.8 PROVIDE TEE, ADAPTORS AND FLEX. COPPER TUBING TO SUIT INSTALLATION. PROVIDE TEMPERED WATER TO HOT SIDE OF FAUCET. MCGUIRE #155AC OPEN GRID DRAIN, CHROME PLATED CAST BRASS ONE PIECE TOP, 17 GA. (1.5MM) TUBULAR 32 MM (1-1/4") TAILPIECE. MCGUIRE #LFH170BVRB, FAUCET SUPPLIES, CHROME PLATED POLISHED BRASS, COMMERCIAL DUTY 1/4 TURN BALL VALVE ANGLE STOPS, 13 MM (1/2") I.D. INLET X 127 MM (5") HORIZONTAL EXTENSION TUBES, COMBINATION V.P. LOOSE KEY HANDLE, ESCUTCHEON AND STAINLESS STEEL BRAIDED FLEXIBLE RISER. MCGUIRE #8872C P-TRAP, HEAVY CAST BRASS ADJUSTABLE BODY, WITH SLIP NUT, 32 MM (1-1/4") SIZE, SHALLOW WALL FLANGE AND SEAMLESS TUBULAR WALL BEND. WATTS #WCA-411-CA-481, BASIN CARRIER, CONCEALED ARMS, WALL FLANGES TO ATTACH TO BACKING PLATE SECURED IN WALL WITH LOCKING DEVICE AND LEVELLING SCREWS, HEAVY GAUGE STEEL UPRIGHTS WITH INTEGRAL WELDED FEET. FOR ONE UNIT: 102 MM (4") FOR TWO TO SIX UNITS IN A ROW: 152 MM (6") FINISHED METAL STUD WALL TO BACK OF PIPE SPACE. AMERICAN STANDARD LUCERNE #0355.012 BASIN, 521 MM X 464 MM X 308 MM (20-1/2" X 18-1/4" X 12-1/8") DEEP, VITREOUS CHINA, FOR CARRIER WITH CONCEALED ARMS, FRONT OVERFLOW, SELF-DRAINING FAUCET LEDGE, CONTOURED BACK AND SIDE SPLASH SHIELD. CHICAGO FAUCETS #420-ABCP SINGLE LEVER FAUCET, CHROME PLATED, 4" (102MM) CENTERSET, LEAD FREE CAST BRASS BODY, CERAMIC 1/4 TURN CARTRIDGE, 5.7 LPM (1.5 GPM) NON-AERATING LAMINAR OUTLET, 131 MM (5-3/16") PROJECTION REACH, LEVER HANDLE, VOLUME CONTROL, ADJUSTABLE HOT LIMIT STOP. LAWLER WALL HUNG BASIN #TMM-1070, POINT OF USE MECHANICAL WATER MIXING VALVE, BRONZE BODY, TEMPERATURE ADJUSTING DIAL, 10 MM (3/8") INLETS AND OUTLET COMPRESSION FITTINGS, HIGH TEMPERATURE SINGLE LEVER FAUCET THERMOSTATIC LIMIT STOP (AUTOMATIC SHUTS DOWN FLOW OF WATER WHEN TEMPERATURE REACHES 48 DEG.C (118 DEG.F) WITH AUTOMATIC RESET, SHUT-OFF WITH AUTOMATIC RESET WHEN TEMPERATURE EXCEEDS 120F (48.8C), INTEGRAL CHECKS, OFFER TEMPERATURE RANGE FROM FULL COLD THROUGH 46 (114.8 PROVIDE TEE, ADAPTORS AND FLEX. COPPER TUBING TO SUIT WC (203), WC (204), TECH. WM'S INSTALLATION. PROVIDE TEMPERED WATER TO HOT SIDE OF FAUCET. MCGUIRE #155AC OPEN GRID DRAIN, CHROME PLATED CAST BRASS ONE PIECE TOP, 17 GA. (1.5MM) TUBULAR 32 MM (1-1/4") WC (134) TAILPIECE. MCGUIRE #LFH165LKN3, FAUCET SUPPLIES, CHROME PLATED POLISHED BRASS, HEAVY DUTY ANGLE STOPS, 10 MM (3/8") I.P.S. INLET X 76 MM (3") LONG RIGID HORIZONTAL NIPPLES, V.P. LOOSE KEYS, ESCUTCHEON AND FLEXIBLE COPPER RISER. MCGUIRE #8872C P-TRAP, HEAVY CAST BRASS ADJUSTABLE BODY, WITH SLIP NUT, 32 MM (1-1/4") SIZE, SHALLOW WALL FLANGE AND SEAMLESS TUBULAR WALL BEND. WATTS #WCA-411, BASIN CARRIER, CONCEALED ARMS, WALL FLANGES TO ATTACH TO BACKING PLATE SECURED IN WALL WITH LOCKING DEVICE AND LEVELLING SCREWS, HEAVY GAUGE STEEL UPRIGHTS WITH INTEGRAL WELDED FEET. FOR ONE UNIT: 102 MM (4") FOR TWO TO SIX UNITS IN A ROW: 152 MM (6") FINISHED METAL STUD WALL TO BACK OF PIPE SPACE. TECH. MEN'S WC (131) 2.3 DRAIN TOILET - FLOOR MOUNTED VITREOUS CHINA TANK TYPE GASOLINE ENGINE EMISSIONS ( CARBON MONOXIDE ) IF HAZARDOUS NO2 GAS CONCENTRATIONS ARE NOT CLEARED AFTER 30 MINUTES OR NO2 GAS CONCENTRATIONS CONTINUE TO INCREASE TO 2 PPM VENTILATION INTERNAL HORN IS TO SOUND AND ALARM CONTACTS SHOULD CONTINUE TO OPERATE THE EXHAUST FANS UNTIL HAZARDOUS GAS CONCENTRATION LEVELS ARE REDUCED TO BELOW SET POINT ALARM LEVELS DHW AMERICAN STANDARD CADET RIGHT HEIGHT PRESSURE-ASSISTED ELONGATED #2467.016.020 LOW CONSUMPTION TOILET, 419 MM HIGH, WHITE VITREOUS CHINA WITH EVERCLEAN ANTIMICROBIAL SURFACE WHICH INHIBITS THE GROWTH OF STAIN AND ODOR CAUSING BACTERIA MOLD AND MILDEW, FLOOR MOUNTED, SIPHON JET FLUSH ACTION, 6 L (1.6 US GAL) PER FLUSH, RAISED SANITARY BAR, 305 MM X 254 MM (12" X 10") WATER SURFACE AREA, TWO PIECE, 'SPEED CONNECT' TANK ASSEMBLY, UNBOLTED TANK COVER, 305 MM (12") ROUGH-IN, ELONGATED BOWL, 54 MM (2-1/8") FULLY GLAZED INTERNAL TRAPWAY, FLOOR OUTLET, BOLT CAPS. PROVIDE BOLTED TANK COVER IF REQUIRED - TO MEET LOCAL CODES. PROVIDE TRIP LEVER ON OPEN SIDE OF TOILET (WIDE SIDE) IF REQUIRED - TO MEET LOCAL CODES.CENTOCO #820STS.001 TOILET SEAT, HEAVY DUTY, FOR ELONGATED BOWL, OPEN FRONT, WHITE SOLID PLASTIC, WITH COVER, REINFORCED STAINLESS STEEL CHECK HINGES, METAL FLAT WASHERS STAINLESS STEEL POSTS AND NUTS. MCGUIRE #LFH166N3, TOILET SUPPLY, CHROME PLATED POLISHED BRASS, HEAVY DUTY ANGLE STOPS, 13 MM (1/2") I.P.S. INLET X 76 MM (3") LONG RIGID HORIZONTAL NIPPLES, WHEEL HANDLES, ESCUTCHEON AND FLEXIBLE COPPER RISER. PROVIDE FLOOR FLANGE, (SAME MATERIAL AS THE CONNECTING PIPE DRAIN), WITH ALL BRASS BOLTS AND WITH RUBBER GASKET. TOILET - FLOOR MOUNTED VITREOUS CHINA TANK TYPE WC-2 IF NOT CLEARED AFTER 30 MINUTES OR CARBON MONOXIDE (CO) GAS CONCENTRATION LEVELS CONTINUE TO RISE THEN, WHILE VENTILATION CONTINUES TO OPERATE, THE INTERNAL HORN WILL BE ENERGIZED. SPECIFICATION DCW CO/NOX GAS DETECTION SYSTEM GAS FIXTURE AMERICAN STANDARD WASHBROOK FLOWISE #6590.001 URINAL, VITREOUS CHINA, OPERATES IN THE RANGE OF 0.5 L TO 3.8 L (0.125 US GAL TO 1.0 US GAL) PER FLUSH, WALL HUNG, EXTENDED SIDES FOR PRIVACY, WASHDOWN ACTION, FLUSHING RIM, 19 MM (3/4") DIA. TOP SPUD, ELONGATED RIM, INTEGRAL P-TRAP, OUTLET CONNECTION 51 MM (2"), 2 WALL HANGERS, #7301242-100 CHROME PLATED, NON-METALLIC STRAINER. SLOAN ROYAL #186-0.5-CP, EXPOSED MANUAL FLUSHOMETER FOR TOP SPUD URINAL, CHROME PLATED, 1.9 L (0.5 US GAL) FACTORY SET FLOW, QUIET ACTION 'PERMEX' DIAPHRAGM TYPE WITH DUAL FILTER BY-PASS, NON-HOLD OPEN FEATURE, A.D.A TRIPLE SEAL OSCILLATING HANDLE, V.P. SMOOTH DESIGN STOP CAP ON BACK-CHECK ANGLE STOP (SCREWDRIVER OPERATED), FLUSH TUBE FOR 292 MM (11-1/2") ROUGH-IN, HIGH PRESSURE VACUUM BREAKER. WATTS #CA-321, URINAL CARRIER, MOUNTED ON CONCRETE FLOOR, EPOXY COATED WITH HEAVY GAUGE STEEL UPRIGHTS WITH WELDED FEET SUPPORTS AND WITH TOP AND BOTTOM UNIVERSAL STEEL HANGER PLATES WITH PLATED HARDWARE, HEAVY GAUGE EPOXY COATED STEEL OFFSET UPRIGHTS. FOR ONE UNIT: 102 MM (4") FOR TWO TO SIX UNITS IN A ROW: 152 MM (6") FINISHED METAL STUD WALL TO BACK OF PIPE SPACE. WATTS #WUCO URINAL WALL ACCESS CLEANOUT, TWO PIECE EXPANDABLE PLUG WITH 102MM (4") DIAMETER STAINLESS STEEL ACCESS COVER, SECURED WITH VANDAL PROOF STAINLESS STEEL SCREW. -- FRANKE COMMERCIAL #LBS6808-1/1 SINGLE BOWL COUNTERTOP MOUNT SINK, 1 HOLE, 521 MM (20-1/2") X 508 MM (20") X 203 MM (8") DEEP, COUNTER MOUNTED, BACKLEDGE, 18-10 TYPE 302 20 GA. (0.9MM) STAINLESS STEEL, SELF-RIMMING, SATIN FINISH RIM AND BOWLS, MOUNTING KIT PROVIDED, FULLY UNDERCOATED TO REDUCE CONDENSATION AND RESONANCE, FACTORY APPLIED RIM SEAL, 3-1/2" (89MM) CRUMB CUP WASTE ASSEMBLY WITH 1-1/2" (38 MM) TAILPIECE. CHICAGO FAUCETS #430-ABCP SINGLE LEVER FAUCET, CHROME PLATED, CENTER HOLE ONLY, LEAD FREE CAST BRASS BODY, 5.7 LPM (1.5 GPM) AERATOR OUTLET, LONG CAST SPOUT 229 MM (9") PROJECTION REACH, LEVER HANDLE, VOLUME CONTROL, ADJUSTABLE HOT LIMIT STOP. MCGUIRE #LFH165LKN3, FAUCET SUPPLIES, CHROME PLATED POLISHED BRASS, HEAVY DUTY ANGLE STOPS, 10 MM (3/8") I.P.S. INLET X 76 MM (3") LONG RIGID HORIZONTAL NIPPLES, V.P. LOOSE KEYS, ESCUTCHEON AND FLEXIBLE COPPER RISER. MCGUIRE #8912CB P-TRAP, HEAVY CAST BRASS ADJUSTABLE BODY, WITH SLIP NUT, 38 MM (1-1/2") SIZE, BOX FLANGE AND SEAMLESS TUBULAR WALL BEND. FRANKE COMMERCIAL #LBS6808-1/1 SINGLE BOWL COUNTERTOP MOUNT SINK, 1 HOLE, 521 MM (20-1/2") X 508 MM (20") X 203 MM (8") DEEP, COUNTER MOUNTED, BACKLEDGE, 18-10 TYPE 302 20 GA. (0.9MM) STAINLESS STEEL, SELF-RIMMING, SATIN FINISH RIM AND BOWLS, MOUNTING KIT PROVIDED, FULLY UNDERCOATED TO REDUCE CONDENSATION AND RESONANCE, FACTORY APPLIED RIM SEAL, 3-1/2" (89MM) CRUMB CUP WASTE ASSEMBLY WITH 1-1/2" (38 MM) TAILPIECE. CHICAGO FAUCETS #430-ABCP SINGLE LEVER FAUCET, CHROME PLATED, CENTER HOLE ONLY, LEAD FREE CAST BRASS BODY, 5.7 LPM (1.5 GPM) AERATOR OUTLET, LONG CAST SPOUT 229 MM (9") PROJECTION REACH, LEVER HANDLE, VOLUME CONTROL, ADJUSTABLE HOT LIMIT STOP. MCGUIRE #LFH165LKN3, FAUCET SUPPLIES, CHROME PLATED POLISHED BRASS, HEAVY DUTY ANGLE STOPS, 10 MM (3/8") I.P.S. INLET X 76 MM (3") LONG RIGID HORIZONTAL NIPPLES, V.P. LOOSE KEYS, ESCUTCHEON AND FLEXIBLE COPPER RISER. MCGUIRE #8912CB P-TRAP, HEAVY CAST BRASS ADJUSTABLE BODY, WITH SLIP NUT, 38 MM (1-1/2") SIZE, BOX FLANGE AND SEAMLESS TUBULAR WALL BEND. STERN WILLIAMS TRIESTE #54 SHOWER FLOOR, 915 MM (36") X 915 MM (36") X 102 MM (4"), PRECAST TERRAZZO, THRESHOLD, 25 MM (1") GALVANIZED-BONDERIZED STEEL TILING FLANGE ON THREE SIDES, INTEGRAL CAST BRASS FLOOR DRAIN 2" (50MM) WITH S.S. STRAINER.. INSTALLED ON LEVEL GROUND OR BED OF MORTAR. CHICAGO FAUCETS #SH-PB1-02-000 SHOWER VALVE, SOLID BRASS BODY, PRESSURE BALANCING, WASHERLESS CERAMIC DRIP-FREE DISC VALVE CARTRIDGE, METAL WALL ESCUTCHEON, 9.5 LPM (2.5 GPM) MAXIMUM FLOW RATE '620A' BALL JOINT SHOWERHEAD WITH ARM AND FLANGE. PROVIDE P-TRAP, SAME MATERIAL AS THE CONNECTING PIPE DRAIN. STERN WILLIAMS #MTB-2424 SQUARE SERVICE / MOP SINK, 610 MM (24") X 610 MM (24") X 254 MM (10") DEEP, FLOOR MOUNTED, TERRAZZO COMPOSED OF PEARL GRAY MARBLE CHIPS AND PORTLAND CEMENT GROUND SMOOTH, SEALED TO RESIST STAIN, CAST BRASS DRAIN WITH STAINLESS STEEL STRAINER, 3"(75MM) OUTLET. CHICAGO FAUCETS #897-369VP-XK WALL MOUNTED TWO HANDLE MANUAL FAUCET, CHROME PLATED, 8" (203MM) CENTERSET, SOLID BRASS EXPOSED BODY, CERAMIC 1/4 TURN CARTRIDGES, UNRESTRICTED HOSE END OUTLET, 200 MM (7-7/8") FROM WALL TO OUTLET SERVICE/MOP SINK TWO HANDLE REACH, INTEGRAL ATMOSPHERIC VACUUM BREAKER, METAL RED AND BLUE INDEX BUTTONS 60 MM (2-3/8") LONG LEVER HANDLES WITH VANDAL RESISTANT SCREW. WALL BRACE SUPPORT. STERN WILLIAMS MANUAL FAUCET A-20 BUMPER GUARD ANODIZED ALUMINUM CAP STERN WILLIAMS T-35 HOSE AND WALL HOOK 36" (914MM) LONG HOSE WITH 3/4" (19MM) CHROME COUPLING, STAINLESS STEEL WALL BRACKET. STERN WILLIAMS T-40 MOP HANGER STAINLESS STEEL #4 FINISH, 24" (610MM) LONG WITH 3 RUBBER SPRING LOADED CLIPS. STERN WILLIAMS BP BACK SPLASH PANEL 20 GAUGE TYPE 304 STAINLESS STEEL. STERN WILLIAMS TC-3 GASKET 3" (76MM) FOR XHCI, PLASTIC AND STEEL PIPE. PROVIDE P-TRAP, SAME MATERIAL AS THE CONNECTING PIPE DRAIN. FD-1 FLOOR DRAIN FINISHED AREA WATTS #FD-100-7-5-1 FLOOR DRAIN - EPOXY COATED, 8-1/8" (206MM) DIAMETER, CAST IRON BODY, REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG. WATTS -5-1 5" (127MM) DIAMETER, NICKEL BRONZE, ADJUSTABLE, HEAVY DUTY, ROUND STRAINER. - - - - FFD FUNNEL FLOOR DRAIN FINISHED AREA WATTS #FD-100-C-A5-1-7-G-1 FLOOR DRAIN - EPOXY COATED, 8-1/8" (206MM) DIAMETER, CAST IRON BODY, REVERSIBLE FLASHING CLAMP WITH PRIMARY AND SECONDARY WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, NO HUB OUTLET. WATTS -A5-1-G-1 5" (127MM) DIAMETER, NICKEL BRONZE, ADJUSTABLE, ROUND STRAINER, 4" X 9" (102MM X 229MM) OVAL NICKEL BRONZE FUNNEL. - - - - HB HYDRANT - NON-FREEZE WALL HYDRANT WITH CHROME FACE, INEGRAL VACUUM BREAKER WATTS #HY-420 HYDRANT, 3/4" (19MM) DIAMETER HOSE CONNECTION, 3/4" (19MM) FEMALE X 1" (25MM) MALE PIPE CONNECTION, NON-FREEZE HYDRANT, ALL BRONZE HEAD, SEAT CASTING AND INTERNAL WORKING PARTS, WALL MOUNT, BRONZE WALL CASING, CHROME PLATED FACE, INTEGRAL VACUUM BREAKER, LOOSE KEY. - - - - NFHB HYDRANT - NON-FREEZE WALL HYDRANT WITH NB FACE, INTEGRAL VACUUM BREAKER WATTS #HY-725 HYDRANT, 3/4" (19MM) DIAMETER HOSE CONNECTION, 3/4" (19MM) FEMALE X 1" (25MM) MALE PIPE CONNECTION, NON-FREEZE HYDRANT, ALL BRONZE HEAD, SEAT CASTING AND INTERNAL WORKING PARTS, WALL MOUNT, CONCEALED, BRONZE WALL CASING, CHROME PLATED FACE, INTEGRAL VACUUM BREAKER, NICKEL BRONZE BOX AND DOOR, LOOSE KEY. - - - - AD FLOOR DRAIN - FLOOR DRAIN WITH 8" (203mm) ROUND ADJUSTABLE COLLAR & HEAVY DUTY GRATE WATTS #FD-320-4-7 FLOOR DRAIN - EPOXY COATED, 8-1/8" (206MM) DIAMETER, CAST IRON BODY, BODY COLLAR WITH WEEPHOLES, TRAP PRIMER CONNECTION WITH PLUG, ANCHOR FLANGE, NO HUB OUTLET. WATTS -4 7-7/8" (200MM) DIAMETER, EPOXY COATED DUCTILE IRON, HEEL-PROOF, ROUND GRATE. - - - - CO CLEANOUT - FLOOR CLEANOUT WITH ROUND TOP WATTS #CO-200-R-34G CLEANOUT - EPOXY COATED, 7" (178MM) DIAMETER, CAST IRON BODY, WITH 5" (127MM) ROUND, ADJUSTABLE, GASKETED, NICKEL BRONZE TOP, REMOVABLE, GAS TIGHT, GASKETED, ABS PLUG WITH NEOPRENE GASKET, NO HUB OUTLET. - - - - TD-1 TRENCH DRAIN - 6" WIDE TRENCH SYSTEM WATTS #D-DI TRENCH DRAIN - UV STABILIZED TALC-FILLED POLYPROPYLENE CHANNELS WITH INTEGRAL 4" (102MM) NO HUB BOTTOM OUTLET(S), PRE-SLOPED TRENCH, 6" (152MM) WIDE, 48" (1219MM) LONG, INCLUDING FRAME CONNECTORS, GRATE LOCKDOWNS AND CONSTRUCTION COVERS, DUCTILE IRON FRAME,FRAMED ANCHORED GRATE, DUCTILE IRON GRATE, CLASS C. - - - - TD-2 TRENCH DRAIN - 6" WIDE TRENCH SYSTEM WATTS #D-DI-B6 TRENCH DRAIN - UV STABILIZED TALC-FILLED POLYPROPYLENE CHANNELS WITH INTEGRAL 4" (102MM) NO HUB BOTTOM OUTLET(S), PRE-SLOPED TRENCH, 6" (152MM) WIDE, 48" (1219MM) LONG, INCLUDING FRAME CONNECTORS, GRATE LOCKDOWNS AND CONSTRUCTION COVERS, DUCTILE IRON FRAME,FRAMED ANCHORED GRATE, DUCTILE IRON GRATE, CLASS C, 6" X 24" X 24" (152MM X 610MM X 610MM) CATCH BASIN. - - - - TD-3 TRENCH DRAIN - 6" WIDE TRENCH SYSTEM WATTS #D-DI-B6 TRENCH DRAIN - UV STABILIZED TALC-FILLED POLYPROPYLENE CHANNELS WITH INTEGRAL 4" (102MM) NO HUB BOTTOM OUTLET(S), PRE-SLOPED TRENCH, 6" (152MM) WIDE, 48" (1219MM) LONG, INCLUDING FRAME CONNECTORS, GRATE LOCKDOWNS AND CONSTRUCTION COVERS, DUCTILE IRON FRAME,FRAMED ANCHORED GRATE, DUCTILE IRON GRATE, CLASS C, 6" X 24" X 24" (152MM X 610MM X 610MM) CATCH BASIN. - - - - TD-4 TRENCH DRAIN - 6" WIDE TRENCH SYSTEM WATTS #D-DI-B6 TRENCH DRAIN - UV STABILIZED TALC-FILLED POLYPROPYLENE CHANNELS WITH INTEGRAL 4" (102MM) NO HUB BOTTOM OUTLET(S), PRE-SLOPED TRENCH, 6" (152MM) WIDE, 48" (1219MM) LONG, INCLUDING FRAME CONNECTORS, GRATE LOCKDOWNS AND CONSTRUCTION COVERS, DUCTILE IRON FRAME,FRAMED ANCHORED GRATE, DUCTILE IRON GRATE, CLASS C, 6" X 24" X 24" (152MM X 610MM X 610MM) CATCH BASIN. - - - - INTERCEPTOR - OIL INTERCEPTOR WATTS #WO-350 INTERCEPTOR - EPOXY COATED INSIDE AND OUTSIDE, FABRICATED STEEL BODY, EPOXY COATED NON-SKID COVER, COVER SECURING BOLTS, STAINLESS STEEL CALIBRATED ORIFICE ON FLOOR OR RECESSED PLATE, CODE APPROVED DEEP SEAL TRAP, 50 GPM, NO HUB CONNECTIONS. INSTALLATION - - - - A TOTAL OF 128 GROUPS CAN BE ASSIGNED. 3.6 RATINGS AND CERTIFICATIONS CONFORMS TO N ORDINARY LOCATIONS INTERNATIONAL ELECTRICAL COD: IEC NO.61010 EMI/RFI COMPLIES WITH EMC DIRECTIVE 89/336/EEC CSA CERTIFICATION 4. 4.1 4.2 4.3 4.4 INSTALLATION PROVIDE ALL NECESSARY LABOUR AND MATERIALS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN FOR A COMPLETE, OPERATING SYSTEM. DRAWINGS SHOWING WORK ARE DIAGRAMMATIC ONLY. EXAMINE THE SITE; TAKE ALL RELEVANT INFORMATION INCLUDING ACCURATE MEASUREMENTS BEFORE ORDERING MATERIALS AND COMMENCING WORK. SHOP DRAWINGS AND INSTALLATION DETAILS: SUBMIT SHOP DRAWINGS FOR ALL EQUIPMENT AND MATERIALS SPECIFIED HEREIN, INCLUDING MONITORING PANEL AND GAS DETECTION TRANSMITTERS. VERIFICATION: AFTER INSTALLATION, TEST OF EQUIPMENT TO DEMONSTRATE OPERATION OF FUNCTIONS DESCRIBED ABOVE UNDER SEQUENCE OF OPERATION BY MANUFACTURES CERTIFIED SERVICE TECHNICIAN. A CERTIFICATE OF COMPLIANCE WITH MANUFACTURERS' INSTALLATION GUIDELINES SHALL BE ISSUED TO THE OWNERS UPON COMPLETION. OI PLUMBING FIXTURE SCHEDULE TAG TSP-1 TSP-2 CB-1 CB-2 CB-3 FIXTURE PIPE SIZES SPECIFICATION DCW DHW DRAIN VENT TRAP SEAL PRIMERS MECHANICAL SMS INC. #PRO1-500 PPP PRIME-PRO TRAP SEAL PRIMER VALVE, LEAD-FREE BRASS BODY, SERVING INDIVIDUAL OR REMOTE AREA DRAINS (PRIMER AUTOMATICALLY ACTIVATED WHEN THERE IS A PRESSURE DROP IN THE SYSTEM) WITH 1/2" (12.7MM) NPT CONNECTIONS WITH STAINLESS STEEL SCREEN AND INTEGRAL NEOPERL CHECK VALVE. (FOR 2, 3 OR 4 DRAINS PROVIDE PRIMER UNIT WITH DISTRIBUTION UNIT ASSEMBLY #DU-4). - - - - TRAP SEAL PRIMERS ELECTRONIC - SERVING 4 TO 30 DRAINS SMS INC. #PT-12 -PTD #PT SERIES (SURFACE MOUNTED) ELECTRONIC TRAP PRIMING MANIFOLD, MODIFIED MANIFOLD TO 3/4" (18MM) DIA. SUPPLY PIPE, THE UNIT SHALL SUPPLY A MINIMUM OF 0.3L (10 OZ.) OF WATER OPENING, 24 HOUR PERIOD OR AS SELECTED WITH ADJUSTABLE RECYCLE TIMER ON A 24 HOUR PERIOD BASED ON A SYSTEM PRESSURE OF 60 PSI (412KPA). FACTORY ASSEMBLED WITH A BRONZE BODY BALL VALVE, WATER HAMMER ARRESTOR, SOLENOID VALVE, ATMOSPHERIC VACUUM BREAKER AND A TYPE L COPPER MANIFOLD C/W COMPRESSION FITTING. ELECTRONIC SINGLE POINT POWER CONNECTION 120V 1AMP DRAW, MANUAL OVERRIDE SWITCH , PROVIDE ACCESS PANEL , 12 OPENING MANIFOLD (UP TO 3.5L (120OZ.) PER MANIFOLD. DEPTH OF CABINET DRY WALL - 4" (102MM) FIRE RATED 6" (150MM) - - - - G REDUCING STATION 17 7 PIPE UP GAS SERVICE BY LOCAL UTILITY COMPANY, CAPACITY 2,600 CFH G G 1 G C (ABOVE) 'WC-1' DRAIN FROM ABOVE CO SAN CO PIPES DROP TO ACCOMMODATE LOW ROOF SAN PIPES RISE UP TO HIGH LEVEL AFTER LOW ROOF 16 (ABOVE) SLOPE @ 1% SAN 'WC-2' (ABOVE) (ABOVE) FD 'U-1' (ABOVE) 3 BFP G A 'L-1' (ABOVE) 10 FFD 'S-2' (ABOVE) CO 'CB-1' 'WC-2' (ABOVE) 13 SAN 'L-1' SAN 2 'SH-1' (ABOVE) 'S-1' CO D 'L-1' 3 'WC-1' DRAIN FROM ABOVE 'TD-4' SAN V 'HWT-1' REFER TO 16 DETAIL 18, ON DRAWING M-1.4 'CB-2' 6 F SAN SAN SAN ST SLOPE @ 1% ST FD 'L-2' (ABOVE) 6 SAN CO TO ROOF SLOPE @ 1% 2 14 ST 'L-1' CO ST TO SEPTIC TANK BY OTHERS. REFER TO SITE SERVICE PLAN G 16 CO V 5 SAN SAN SAN SAN SAN SAN SAN ST 18 12 11 SAN E 'WC-1' 3 CO 16 V FD 15 B 'SH-1' (ABOVE) SLOPE @ 1% SAN 'TD-1' CO 'TD-2' 4 'WC-2' (ABOVE) V 'WC-2' (ABOVE) 'L-2' (ABOVE) CO 'L-2' (ABOVE) INT-1 CO SAN SLOPE @ 1% SAN SAN 16 V CO H V ST 8 V (ABOVE) CO ST (ABOVE) J EF-10 16 16 BELOW SLAB TO ROOF ST 'TD-3' AND DHW K LOW ROOF DRAIN ABOVE (TYP. OF 3) ST 'CB-3' CO 6 6 L 'S-2' (ABOVE) DHW UP TO SERVE 'S-2' CO DRAWING NOTES: N M 1 NEW DOMESTIC COLD WATER METER, CONNECT BELOW GRADE EXTERIOR TO UTILITY SERVICE. REFER TO DETAIL 16 ON DWG. M-1.3 FOR INSTALLATION DETAIL. 2 SLAB. 3 4 OIL INTERCEPTOR. REFER TO DETAIL 2 ON DRAWING M-1.2. PROVIDE OIL STORAGE TANK. COORDINATE WITH OWNER FOR TANK CAPACITY. INSTALL TANKS AS PER MANUFACTURER REQUIREMENTS. 5 LOCATION. 6 PROVIDE FLUSH MOUNTED INTERIOR/EXTERIOR NON-FREEZE HOSE BIBB. 7 8 DRAWING M-1.3 9 SANITARY LINE UP TO SERVICE 'L-1' AND 'WC-1' ON HIGH LEVEL/MEZZANINE LEVEL. SEE DRAWING M-3.1 FOR CONTINUATION. GENERAL NOTES: 1. CONTRACTOR TO CLEAN ALL DEBRIS AND RUBBISH GENERATED FROM THIS WORK. 2. ALL PENETRATIONS THROUGH FIRE RATED DEMISING WALLS AND ROOF DECK SHALL BE FIRE STOPPED AND SEALED. 3. COORDINATE WITH ALL TRADES FOR NEW PLUMBING FIXTURE AND PIPING INSTALLATION. ROOM. 12 (L-1) IN THE TECH WASHROOM. THE TECH WASHROOM. 5. AUTOMATIC PRIMING SYSTEM. TSP REFER TO PLUMBING SCHEDULES. GROUND FLOOR PLAN - PLUMBING AND DRAINAGE 11 13 4. 6. 10 PROVIDE AUTOMATIC ELECTRONIC TRAP SEAL PRIMER. ALL PLUMBING VENT PIPING SHALL BE INSIDE WALLS AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE OBC (PART 7). UNLESS OTHERWISE INDICATED. 7. CONTRACTOR TO COORDINATE ALL TRADES TO ENSURE NO INTERFERENCE OF NEW SYSTEMS. (SHEET METAL, PLUMBING, ETC.). 8. ALL DOMESTIC COLD AND HOT WATER PIPE SHALL BE INSULATED. 14 15 (L-1) IN WASHROOM CLOSET WC1 AND WC2. 16 17 PROVIDE BOLLARD PROTECTION FOR GAS METER. 18 CONNECT TO EXISTING STORM SERVICE LINE AT THIS APPROXIMATE LOCATION. 1 2 3 4 5 6 7 8 9 10 BELOW UP TO ROOF 11 12 13 14 15 11 A B 16 10 8 ST CO ST ST 17R ST DN STAIR DN No1 9R@189 C ST STORAGE ROOM 4 3 ST RD ST ST E ST FROM ROOF DRAIN ABOVE ST 'L-2' FD 'SH-1' 211 'WC-2' WM'S LOCKER1RM 209 ST 210 ST ST 9 'U-1' 'U-1' 2 LUNCH ROOM 5 TO ROOF 5 6 8 WM'S WC 'S-2' 7 FD FROM ROOF DRAIN ABOVE 3 6 213 D 12 ST ST ST CO ROOF (TYP.) ADMIN FROM ROOF DRAIN ABOVE 201 ST 'SH-1' 212 FD 207 'WC-2' 2 TO ROOF MEN'S WC CORRIDOR 208 12 'L-1''L-1' MEN'S LOCKER RM A B FROM ROOF DRAIN ABOVE STORAGE ROOM CUSTOMER LOUNGE 214 200 F ST F OPEN TO SERVICE DEPARTMENT BELOW DRIVE-THROUGH ROOF BELOW ST MEETING ROOM 202 G ST RD 3 ST OPEN TO AUDI FROM ROOF SHOWROOM BELOW DRAIN ABOVE 3 'WC-2' 2 1 WC 204 4 203 ROOF (TYP.) 2 1 H 'L-2' 'L-2' ST J FD WC 'WC-2' FD 4 TO ROOF (TYP.) ST UPPER PARTS STORAGE ST 215 RD K L CO 4 FROM ROOF DRAIN ABOVE 'S-2' 1 OPEN TO PARTS DELIVERY BELOW GEN.MGR M 206 N GENERAL NOTES: 1. CONTRACTOR TO COORDINATE ALL TRADES TO ENSURE NO INTERFERENCE OF NEW SYSTEMS. (SHEET METAL, PLUMBING, ETC.) KEY NOTES: 1 2 3 SANITARY SERVING 'WC-2'. 4 SANITARY SERVING 'L-2'. 5 SANITARY SERVING 'U-1'. 6 7 8 SANITARY SERVING 'SH-1'. 9 SANITARY SERVING 'S-2'. 10 SANITARY SERVING 'L-1'. 11 12 SECOND FLOOR PLAN - PLUMBING AND DRAINAGE 1 2 3 4 5 6 7 8 B 9 10 11 12 13 14 15 PROVIDE SUPPORTS FOR ALL GAS PIPING ON ROOF. SEE DETAIL ON DRAWING 10/M-1.3. (TYP.) PIPING FROM BELOW 3 A 16 ROOF HEIGH POINT G G G G G G G G G G G G RD G EF-9 SLOPE RD RD VENT THRU ROOF G G RTU-6 SLOPE 1 MUA-1 G DUCT DROPS LOCATED IN-BETWEEN BEAMS G G G G R.D. EF-8 G RTU-3 R.D. RTU-4 EF-10 G RD RD ROOF HEIGH POINT G G G BEAMS (TYP.) EF-7 DUCT DROPS LOCATED IN-BETWEEN BEAMS ROOF HEIGH POINT RTU-1 4 2 G G G F 7.5 TON G G G G G SLOPE 1200x500 SUPPLY DUCT DOWN SLOPE 15 TON (350 MBH) PROVIDE 100mm HIGH CONCRETE PAD (TYP.) DUCT DROPS LOCATED IN-BETWEEN BEAMS G G G R.D. G G G NECK D 3 TON 115 MBH RD R.D. G R.D. R.D. E VENT THRU ROOF RD R.D. G VENT THRU ROOF EF-6 G G 8400 G SLOPE G PROVIDE 100mm HIGH CONCRETE PAD FOR ALL ROOF TOP UNITS (TYP.) RTU-5 G G G G GAS LINE DROPS TO LOWER ROOF G G SLOPE 0.000 NECK G GAS LINE RISES FROM LOWER ROOF G G HEIGH POINT SLOPE C 3 VENT THRU ROOF (TYP.) H 10 TON G 7.5 TON J LADDER AND ROOF HATCH ABOVE 10 TON VENT THRU ROOF RTU-7 G DUCT DROPS LOCATED IN-BETWEEN BEAMS NECK DUCT DROPS LOCATED IN-BETWEEN BEAMS SLOPE SLOPE DUCT DROPS LOCATED IN-BETWEEN BEAMS SLOPE RTU-2 SLOPE 7.5 TON RD K L RD R.D. SLOPE 1 HEIGH POINT ROOF HEIGH POINT N M GENERAL NOTES: 1. CONTRACTOR TO COORDINATE ALL TRADES TO ENSURE NO INTERFERENCE OF NEW SYSTEMS. (SHEET METAL, PLUMBING, ETC.) 2. CONTRACTOR TO PROVIDE NEW ROOF TO UNITS, EXHAUST FANS, DUCTWORK AND ACCESSORIES AS INDICATED. 3. CONTRACTOR TO PROVIDE ACOUSTICAL LINING IN ALL SUPPLY DUCTS AND RETURN DUCTS FROM RTUs, FOR THE FIRST 5 FEET, (1524mm) (MINIMUM). 4. CONTRACTOR TO PROVIDE THERMAL INSULATION ON ALL EXHAUST DUCTS, FOR THE FIRST 10 FEET (3048mm) FROM THE OUTSIDE. 5. ALL DUCT OPENINGS AND GOOSENECKS SHALL BE MIN 24" (600mm) ABOVE ROOF LEVEL. 6. ALL EXHAUST OPENINGS SHALL BE EQUIPPED WITH BIRD SCREEN. KEY NOTES: 1 700x400 GOOSENECK FROM BELOW C/W BIRDSCREEN. 2 750x450 GOOSENECK FROM BELOW C/W BIRDSCREEN. 3 4 ROOF PLAN - HVAC AND ROOF DRAIN LAYOUT EXHAUST FAN 'EF-4' BY EQUIPMENT SUPPLIER. 6 7 6 7 10 104 UP R19@189 G WC 1 A OFFICE 109 FD SAN 2 'L-1' 9 E 'WC-1' SAN SAN G C 10 106 CO 11 12 G G G 17R UP TOOL ROOM SAN 119 THROUGH ROOF 2 SAN 'WC-1' 1 STAIR NO 2 KEY ROOM STORAGE 'WC-2' 8 2 110 'L-1' (ABOVE) SAN 118 111 (ABOVE) WC 2 FD SAN 108 J 1 'S-1' 'L-1' 'L-2' (ABOVE) UP 'L-2' (ABOVE) WORKBAY AREA DN UP TO ROOF E 18 WASHROOM - WC-1 (107) AND WC-2 (108) 13 14 PLUMBING AND DRAINAGE UP TO WC (203) AND WC (204) TOOL ROOM 120 / TECH. WC 121 15 3 'L-1' (ABOVE) 11 G B G G ELECTRICAL ROOM G BFP M 4 MECHANICAL ROOM 'SH-1' (ABOVE) (ABOVE) FFD 'S-2' (ABOVE) 122 G 121 1 (ABOVE) CO 'WC-2' (ABOVE) G SAN TO ROOF DRAWING NOTES: CO 'U-1' (ABOVE) SAN GENERAL NOTES: 1. CONTRACTOR TO CLEAN ALL DEBRIS AND RUBBISH GENERATED FROM THIS WORK. 2. ALL PENETRATIONS THROUGH FIRE RATED DEMISING WALLS AND ROOF DECK SHALL BE FIRE STOPPED AND SEALED. 3. COORDINATE WITH ALL TRADES FOR NEW PLUMBING FIXTURE AND PIPING INSTALLATION. SLAB. 2 3 'HWT-1' 11 D G 4. 4 PROVIDE AUTOMATIC ELECTRONIC TRAP SEAL PRIMER. 5 ROOM. 5. AUTOMATIC PRIMING SYSTEM. 6 (L-1) IN THE TECH WASHROOM. 6. ALL PLUMBING VENT PIPING SHALL BE INSIDE WALLS AND INSTALLED IN ACCORDANCE WITH THE OBC (PART 7). UNLESS OTHERWISE INDICATED. 7 THE TECH WASHROOM. 10 WORKBAY AREA 8 9 (L-1) IN WASHROOM CLOSET WC1 AND WC2. MECHANICAL ROOM 123 - PLUMBING AND DRAINAGE 10 11 WALL. SAN 120 'L-2' (ABOVE) 19R 'SH-1' (ABOVE) SAN UP TO ROOF SLOPE @ 1% F&I TECH.WC 5 (ABOVE) 107 (ABOVE) SAN SLOPE @ 1% SAN 'WC-2' (ABOVE) 'WC-1' 10 7 FD 'WC-2' (ABOVE) 6 2 3 4 5 6 7 8 9 10 11 12 13 F C FFH-1 3.0 kW T VOID AUDI EXCLUSIVE VOID --- FRD T SLOPE B 104 94 T 17R UP T 57 UP R19@189 1 DUCT UP TO ROOF TRENCH DRAIN B 105 TOOL ROOM PROVIDE NEW 2kW FFH C/W INTEGRATED THERMOSTAT. 119 208V/1PH. COORDINATE WITH DIV.16 (CEILING MOUNTED) FFH-1 3.0 kW STAIR NO 2 118 T TO RTU-1 U/C 38 'EF-2' 350x250 G 200x200 108 WORKBAY AREA CO/NOX DETECTOR 43 TO UH-1 UP AT HIGH LEVEL T 43 SERVICE DEPARTMENT SERVICE DRIVE-THROUGH 109 'BP-8' 123 117 TRENCH DRAIN 5 600x300 103 STORAGE 111 U/C 'BP-7' BD 38 B 1 B 24 38 B B 24 T 200x250 TO UH-1 UP AT HIGH LEVEL CORRIDOR 300x200 300x200 DN PARTS MGR UP TO RTU-4 CO/NOX DETECTOR 126 'BP-5' T DN RETAIL PARTS 112 28 127 GATE TECH.PARTS 125 F.F.E.+306.15 (TYP. OF 6) WORKBAY AREA DN BOUTIQUE 113 116 OFFICE T 300x200 115 SER.MGR 200x250 TRENCH DRAIN 17R OFFICE H 124 WRITE-UP TO RTU-2 T 124B UP 350x250 350x250 19R N F 500x250 J 100 D UPPER GLAZING. REFER TO BLDG ELAVATIONS 4 VESTIBULE FRD ---- C B 450x350 SALES 'BP-6' T --600x300 T 110 K F WC600x300 2 B KEY ROOM B T CO/NOX DETECTOR WORKBAY AREA OFFICE 102 2 122 107 OF 10) (TYP. FULL HEIGHT GLAZED SCREEN 101 'EF-12' 1 F&I RECEPTION 'EF-11' 121 TO UH-1 UP AT HIGH LEVEL (TYP. OF 3) AUDI SHOWROOM ELECTRICAL ROOM B 120 T 350x250 B M MECHANICAL ROOM 3 CO/NOX DETECTOR 300x250 E M FRD 'EF-3' DUCT UP TO ROOF 106 'EF-1' FRD 2 TECH.WC WC 1 U/C 16 3 STAIR NO.1 NVD 15 600x300 TO UH-1 UP AT HIGH LEVEL A 14 BBH (1.5 kW) 1 TO UH-1 UP AT HIGH LEVEL B 33 125C TO UH-1 UP AT HIGH LEVEL T CO/NOX DETECTOR TO UH-1 UP AT T HIGH LEVEL 6 L PARTS DELIVERY 128 T 114 UH-1 TO HIGH LEVEL F.F.E.+306.15 SLOPE B 33 T TO UH-1 UP AT HIGH LEVEL M VOID BBH (1.5 kW) BBH (1.5 kW) B BBH (1.5 kW) 57 OHAC-1 OVER HEAD AIR CURTAIN DOOR 7 (TYP.) B 57 GENERAL NOTES: 1. B 57 2. GROUND FLOOR PLAN - HVAC CONTRACTOR TO COORDINATE ALL TRADES TO ENSURE NO INTERFERENCE OF NEW SYSTEMS. (SHEET METAL, PLUMBING, ETC.) KEY NOTES: 1 CONTRACTOR TO UNDERCUT DOOR 20mm. 2 PROVIDE ELECTRICAL ROOM VENTILATION SYSTEM ACTIVATED BY REVERSE ACTING THERMOSTAT. CONTRACTOR TO PROVIDE NEW ROOF TOP UNITS, CAV BY PASS FAN POWERED TERMINAL UNITS, EXHAUST FANS, DUCTWORK, DIFFUSERS, GRILLES, BALANCING DAMPERS, FIRE DAMPERS, THERMOSTATS, CONTROL WIRING, AND ACCESSORIES AS INDICATED. 3. CONTRACTOR TO BALANCE DUCT SYSTEM AS INDICATED. 4. PROVIDE ACCESS PANEL FOR ALL CAV BY PASS BOXES WHERE REQUIRED (GWB CEILING). EXHAUST FAN ([email protected]"SP) SHALL BE INTERLOCKED WITH AIR INTAKE GRILLE (600/300 IN SIZE) MOTORIZED DAMPER AND EXHAUST AIR OUTLET LOUVER (600/300 IN SIZE) MOTORIZED DAMPER C/W 120/24V TRANSFORMER FOR ALL MOTORIZED DAMPER. CONTRACTOR SHALL COORDINATE FINAL LOCATION WITH ELECTRICAL EQUIPMENT (TRANSFORMER AND SWITCH GEAR) ON SITE. 3 FIRE RATED DAMPER AT HIGH LEVEL. 5. PROVIDE ACCESS PANEL IN DUCTWORK FOR ALL FIRE DAMPERS. 4 250x200 SUPPLY AND 300x200 RETURN DUCTWORK FROM ABOVE. 6. ALL ELECTRICAL HEATERS TO BE SUPPLIED AND INSTALLED BY ELECTRICAL DIVISION. 5 600x300 SUPPLY AND 700x300 RETURN DUCTWORK FROM ABOVE. 6 CONTRACTOR TO PROVIDE UNIT HEATER WITH VENTING (FRESH/EXHAUST AIR), GAS PIPING, SUPPORTS, CONTROLS, AND ELECTRICAL. REFER TO DETAIL 12 ON DWG 1.3 FOR INSTALLATION. 7 ELECTRIC BASEBOARD HEATER (BBH) TO BE SUPPLIED AND INSTALLED BY DIV.16. 1 2 3 A 4 5 6 7 236 71 B B (TYP. OF 3) B 10 11 12 14 15 E DUCT UP TO ROOF 47 A 150 16 24 200x150 200 A E 118 A 250x250 150 (TYP. OF 2) 4 A B G ---- (TYP. OF 6) SLOT RETURN GRILLES (TYP. OF 3) 400x400 UP TO 'EF-9' ON ROOF T 750x450 EXHAUST DUCT TERMINATING AT 450mm ABOVE FINISHED FLOOR 47 B 47 UH-1 300x300 UP TO 'EF-6' ON ROOF MD 4 2 G 3 BD 500x400 BD 500x400 UP TO 'EF-10' ON ROOF 8 UH-1 G 200 BD 700x400 - --- BD 900x500 800x800 UP TO 'EF-8' ON ROOF H 9 350x250 B G 250x250 C UH-1 150x150 200 200x200 4 9 C 300x250 850x400 C 1300 900x300 236 450x200 (TYP. OF 6) 1 57 1 UH-1 UH-1 G B 200 G 350x200 FRD G DUCT UP TO ROOF U/C 300x250 1 750x450 'BP-3' U/C 950x350 450x300 'EF-4' 5 750x400 6 FRD 550x300 1 G 'BP-2' C T 4 F TO 'EF-7' ON ROOF BD 4 'BP-4' D G 11 1 500x350 (TYP. OF 2) 'EF-5' 950x350 G 450x200 MD 200x200 300x250 'BP-1' 450x300 450x350 B 4 7 (TYP.) G T 750x400 J G G 1000x450 F G G 500x350 10 G 200x150 236 500x350 BD 250x200 G 33 (TYP. OF 6) 250x250 900x700 250x150 200x150 76 C 350x250 900x350 (TYP. OF 2) 450x350 U/C U/C 750x450 B G 450x350 UH-1 E G 200x150 200x150 350x350 DUCT FROM BELOW AND UP TO ROOF G G E 1 G 47 G 600x300 E G ---- 750x450 650x350 C G (TYP.) 400x300 B K 13 BBH (1.5 kW) C G 9 TERMINATION CAP, REFER TO DETAIL 3 ON DWG M-1.2 FOR INSTALLATION (TYPICAL) 2-SLOT LINEAR DIFFUSERS (TYP.) A 8 BELOW UP TO ROOF (TYP. OF 3) T G G G G G MD G G L 1 2 TO UH-1 AT LOW LEVEL A T 250x250 700x400 75 250x250 TERMINATION CAP, REFER TO DETAIL 3 ON DWG M-1.2 FOR INSTALLATION (TYPICAL) UH-1 200x200 400x300 M 'EF-13' 750x450 EXHAUST DUCT TERMINATING AT 450mm ABOVE FINISHED FLOOR (TYP.) N BBH (1.5 kW) BBH (1.5 kW) BBH (1.5 kW) B 71 C 283 450x200 (TYP. OF 6) A 236 2-SLOT LINEAR DIFFUSERS (TYP.) B 71 B 71 GENERAL NOTES: KEY NOTES: 1. CONTRACTOR TO PROVIDE NEW A/C UNITS, FANS, DUCTWORK, DIFFUSERS, GRILLES, BALANCING DAMPERS, FIRE DAMPERS, CEILING FANS, THERMOSTATS AND ACCESSORIES AS INDICATED. 1 CONTRACTOR TO PROVIDE UNIT HEATER WITH VENTING (FRESH/EXHAUST AIR), GAS PIPING, SUPPORTS, CONTROLS, AND ELECTRICAL. REFER TO DETAIL 12 ON DWG 1.3 FOR INSTALLATION. 2. CONTRACTOR TO BALANCE DUCT SYSTEM AS INDICATED. 2 700x400 DUCTWORK C/W MOTORIZED DAMPER UP THROUGH ROOF. INTERLOCK WITH 'EF-7'. 3. NATURAL GAS LINE SHALL BE CLEARLY INDICATED AS PER CAN/CSA-B149.1-05. PROVIDE PRESSURE REGULATOR FOR EACH PIECE OF EQUIPMENT IF NOT PROVIDED BY THE MANUFACTURER. 3 750x450 DUCTWORK C/W MOTORIZED DAMPER UP THROUGH ROOF. INTERLOCK WITH ROOF MOUNTED EXHAUST FAN 'EF-9'. 4 750x400 SUPPLY AND 950x350 RETURN DUCTWORK FROM ROOF TOP UNITS. SEE DRAWING M-2.2 FOR CONTINUATION. 5 TAIL PIPE EXHAUST C/W ALL DUCTWORK SHALL BE SUPPLIED AND INSTALLED BY OWNER, EQUIPMENT SUPPLIER. 200 CFM FOR EACH BAY. 6 600x300 SUPPLY AND 700x300 RETURN DUCT DOWN TO GROUND FLOOR. SEE DRAWING M-3.0 FOR CONTINUATION. 7 BY-PASS BOX. SEE DRAWING M-1.4 FOR DETAILS. 8 1200x500 SUPPLY DUCTWORK UP TO ROOF MOUNTED MUA-1. 9 350x200 SUPPLY AND 350x250 RETURN DUCTWORK FROM BELOW. 10 1200x350 SUPPLY AND 900x700 RETURN DUCTWORK FROM ROOF TOP UNIT 'RTU-1'. 11 500x350 SUPPLY AND 700x300 RETURN DUCTWORK FROM ROOF TOP UNIT 'RTU-5'. SECOND FLOOR PLAN - HVAC