SHR950 Permanent Hair Removal Machine-DORA-I

Transcription

SHR950 Permanent Hair Removal Machine-DORA-I
SHR950 Permanent Hair Removal
Machine-DORA-I
Contact us:
Manufacture: Forever Beauty Laser Co.,Ltd
Website: www.foreverbeautylaser.com
Address: Wa Yao Tou Dong Jie , Dou Da Lu Xi Ce ,
Dou Dian Zhen , Fangshan District ,
Beijing City, China .
Phone: 0086-10-80303402;
Fax: 0086-10-80303402
Email: [email protected]
www.foreverbeautylaser. com
Features:
Permanent Hair Removal/Skin Rejuvenation/Vascular Removal
Fast treatment. Frequency up to 10Hz!
Big spot size: 15*50mm 10*15mm and 12*30mm Spot size available
Painless: new AFT technology (Advanced Fluorescence Technology) uses low and
equal energy. The special filter cut s 950-1200nm wavelength, which is useless in
treatment and absorbs water to make patient feel painless
Hairfree,even on work on blonde, red or fine hair
Skinfree, suitable for all skin types, even tanners
www.foreverbeautylaser. com
Machine Parts Introduction
10.4inch Touch Screen
Emergency Button
Key Switch
LED Blue Light
Professional Plug
Different View of Product display
China Unique Design For Screen Position
Pull this part, screen can be stretched
into different angle as picture show
What's SHR ?
SHR=Super Hair Removal,it's a revolutionary technology of hair removal which
is having a sweeping success. (adopt technology AFT (Advanced Fluorescence
Technology) and EDF
SHR combines laser technology and the benefits of the pulsating light method
achieving practically painless results.
SHR combined with “In Motion” represents a breakthrough in permanent hair
removal with light technology. The treatment is more pleasant than with the
conventional systems and your skin is better protected.
Conventional devices, not using SHR technology, merely transport energy along
the melanin to the follicles
SHR gently transports the energy through the skin and through the melanin to the
hair follicles
Advantages:
SR :
SR is for facial treatment, you can choose this option for pores constringency, it can
reduce fine wrinkles; shrink skin pores and to effectively improve coarse pores. also
improve the skin to make it whiter.
HR
1. HR is used for removing the hair, which is black and strong, such as: armpit hair,
etc. also for fine hair, such as: lip hair, etc.
2. Wrinkle removal.
VR
1. VR is used for removing the strong vessels on the face, which means you can
obviously see the venation of the vessels. Also for removing the vessels, which are
not very strong; you can only see that there are rubefaction on the face, but the
venation of the vessels are not very clear.
1.
2.
3.
4.
5.
6.
7.
8.
User-friendly software design: simple parameters setting and easy operation,
Male/female, Skin Type, Hair Density, Hair Color, Hair Thickness Mode choose.
SHR Fast hair removal technology
quick shooting 1-10 per second, achieve instant large area treatment by sliding
probe on skin only
3 handpieces, with the Germany Imported xenon lamps, offer 400,000.00 more
shots
Professional design of inner headpiece structure: greatly prolong the xenon
lamp life and enhance efficiency than traditional headpiece in market
100% American/Germany imported “plug and play” handle connections:
translate into reliable and long lasting machines capable of continuous work in
busy clinics/salons
Alarm protection system of water flow and water temperature: stop all working
immediately in case of any risk, protecting people & machine against any risk at
the first time
Painless—sapphire temperature cool down 0~100C, make clients more
comfortable in the whole treatment; also no scar in/after treatment
Professional Operate Interface Screen
User-friendly software design: simple parameters setting and easy operation,
Male/female, Skin Type, Hair Density, Hair Color, Hair Thickness Mode choose
Difference with Traditional IPL:
Compare with Traditional IPL
Paramet-er
Normal IPL
SHR950
Advantages
Work Mode
Multi pulse
mode
Single pulse mode
Single pulse mode can emit
energy averagely,
however, multi-pulse mode
focus energy
on first pulse, which is very easy
to burn
Wavelength
640-1200nm
650-950nm
SHR filtered violet light and
infrared light,
which will eradiate and absorb
water
from target skin. So SHR does
not have
any side-effect to body.
EDF
Technology
Unavailable
Available
Make sure energy output
accurate
and same with the display all the
time,
Frequency
0.2-1Hz
1-10Hz
Which accelerate operation
speed
and short a lot of time for
Work technology
Stationary
techno-logy
Stationary
technology & Inmotion technology
Moving IPL can use less time to
do
treatment on back, leg and arm.
SHR950 Specification
Technical specifications:
Wavelength (Spectrum)
650-950nm(SHR) 590-950nm(VR) 530-950nm(SR)
Energy Density (Fluence)
1-50J/cm²
Spot Size
15x50mm² ( SHR);12x30mm² (VR);10×50mm(SR)
Pulse Repetition Rate
1-10Hz
Cooling
Continuous Crystal contact cooling (-4°C-2°C ) + Air
cooling + Closed water circulation cooling
Stand-by Working
Continuously for 18 hours
Display
10.4" True Color LCD Touch Screen
Electrical Requirements
100-240VAC, 20A max., 50/60Hz
Net Weight
60 kgs
Dimensions (WxDxH)
63*53*126cm
SHR950 FAQ:
FAQ
1.Who is suitable for SHR?
SHR is designed to suit everyone, especially those who failed conventional light
based hair removal systems such as IPL or Lasers. SHR will help you achieve less
or no hair on those areas that trouble you. It is suitable for all skin types, even on
dark toned skin and sensitive skin. It also works on light coloured and fine hair.
2.Is it painful?
No, it is not painful. It is a very comfortable procedure that can be used on the
most sensitive body parts like Brazilian or Bikini. This is recommended for people
with lower pain threshold.
3.How many sessions are required?
We recommend a minimum of 6 sessions per zone and each session on a monthly
interval basis. For those who are slightly more hairy, they may need up to 10
sessions.
4.How do I prepare for my hair removal session?
Avoid tanning the area to be treated for at least 7 days prior to treatment. Do not
scrub or wax the areas to be treated for at least 7 days. If you develop rashes or itch
over the areas to be treated, please inform your doctor or therapist to postpone
your treatment.
Befor&After
5.What should I do after each session?
Typically you will have slight redness over the treated areas for a few hours to one
day. Apply soothing moisturizer post treatment. Apply sunscreen over the area.
Avoid picking or scratching the area treated.
6.How long must I wait for the next session?
Depending on the hair re-growth cycle, you can return 4-6 weeks for the next
session.
7.Is SHR hair removal permanent?
SHR hair removal targets the deeply seated hair follicles and permanently damage
them as opposed to shaving, waxing, hair removal creams which only serve to
remove the hair shaft. Unless you have gone through hormonal imbalances caused
by pregnancy, menopause, intake of hormone pills, most people enjoy permanent
hair reduction/removal.
Before&After
Before
Before
After
After
Before
Before
After
After