Bio-Medical - Haier.com Worldwide
Transcription
Bio-Medical - Haier.com Worldwide
2015 -01 Brand Building, Haier industrial park, No. 1 Haier Road, Qingdao,266101,P.R.China Tel: +86-0532-88936011 / 5955 Website: www.haiermedical.com Note: If slight difference occurs between pictures and actual products, please refer to actual products. Our company reserves the right of final interpretation to this brochure and please contact with us for future information you might need. Bio-Medical 2015 Biomedical Group Profile Factories around the world America 3 1 2 1 12260 Europe 4 1 2 15100 Africa 4 2520 Haier wasfounded in 1984. In the last 30 year s , through its entreprene urial and innovative spirit, Haier has transformed itself from anns olvent collectively -owned factory on the brink of bank ruptcy in to the numb er one global home appliance brand. In 20 14, Haier’s global revenue and profit reached RMB 200.7 billion (USD 33.2 billion ) and RMB15 billion (USD 2.48 billion ) respectively. Profit growth was 2 times revenue growth. Based on the statistics of Euromonitor International, a world leader in strategy research for consumer markets, Haier has been the number one global home appliance brand for five years in a row. On the 2012 World’s 50 Most Innovative Companies list publish ed by the Boston Consulting Group, Haier was the only Chinese company in the top 10, as well as the top-ranked consumer product retailer. Haier is known for disruptive innovation in its product solutions and management model. As an open platform company, Haier provides leading home appliance solutions to its users. Qingdao Haier (600690.SH), referred to internally to as the 690 Platform, uses disruptive innovation to create smart appliances for its users with the aim of becoming the leader in the home appliance industry. Haier’s five R&D centers around the world have forged strategic partnerships with first-class suppliers, research institutions, and prestigious universities to create an innovative ecosystem composed of over 1.2 million scientists and engineers connected by virtual and physical networks. By the end of 2013, Haier had filed 15,737 patent applications accumulatively and had been granted 10167 patents. Haier Appliances (1169.HK) creates a commercial ecosystem based on an interactive platform and a delivery platform. By leveraging the synergy of marketing, virtual, logistics and service networks (“quadruple play model”) to build competitiveness, it can provide delivery and installation services to users within 24 hours and create the best user experience thanks to the connectivity between virtual and physical networks. The competitive advantages of the quadruple play model have helped its distribution channel Gooday attract famous domestic and international brands, while its open logistics platform for over-sized items serves China’s top five e-commerce retailers and home appliance and furniture manufacturers. Innovation is the key to Haier’s long-term sustainability and health. Since 2007, Haier’s profit has been growing at a CAGR of 35%. Thanks also to a negative 10-day cash conversion cycle (CCC), Haier is outperforming its peers by a mile. East Europe 1 2 2390 West Asia 2 2380 Medit 1 1 3 2660 South Asia 1 1 6 3560 China 42 12 3 35190 5 East Asia 3 2 1 1550 Southeast Asia 5 3 2670 1 Australia 1 610 Worldwide Network Trading Company R&D Center Manufactory Industry Park Sales Network Overseas 19 5 24 4 45800 Global 61 8 29 16 80990 Bio-Medical Founded in 1998, Haier Bio-Medical is based in China. We design, manufacture and market laboratory equipment for the global market. Our products are designed to enable scientific researchers across the globe to perform research projects and to produce pharmaceutical products. Our products include ultra-low temperature freezers, blood banks, pharmacy refrigerators, ice-lined vaccine refrigerators, laboratory freezers, washers, fume hoods, biosafety cabinets and other types of equipment for the laboratory and medical applications. Installations can be found in blood banks, hospitals, epidemic prevention services, universities, pharmaceutical manufacturers, and national laboratories. The successful growth of our business drove a continuous development of our manufacturing ability. Along with many state of the arts manufacturing equipment, we added a facility of 56,700 square meters in 2001 to meet the increasing demand of our customers. Headquartered in Qingdao, China, our company is a part of Haier Group Company which is highly ranked as one of the key global manufacturers of durable goods. In addition to certification with ISO9001 quality system, ISO14001 environment protection system, and ISO13485:2003 quality system, the company has been awarded the People’s Republic of China Medical Device Manufacturing Enterprise License, People’s Republic of China Medical Device Registration Record, and Record of Medical Device For Medical Device Category A,B and C from the State Food and Drug Administration. Our research and development team consists of highly qualified and selective professionals specialized in refrigeration technology, control technology, remote sensing, sample protection and handling, and networking technology. Our business strategy and technological advancement have been very effective since the founding of the company. We now have shipped products to clients in over 100 countries. 01 02 Milestones & Awards World Health Organization (WHO) qualified Haier Medical as the supplier of ice-lined refrigerators and -25°C vaccine and ice pack freezer lines. The pre-qualified models include HBC-70, HBC-200, HBD-286, HBD-116. Haier -150°C cryogenic freezer launched into the market – Haier medical and laboratory freezers coverd most of the temperature range required by market. The Deep Freezer(-40℃) came out, Haier entered into Medical and Laboratory Industry. 1998 2005 Haier won the government procurement tender for International Assistance Program to Cuba from China. 2007 2006 2009 2008 Haier successfully provided MOH tender of Uzbekistan Sudan, Tanzania, Uganda and Madagascar etc., which is a new important milestone to develop the African market. Haier won the tender "Third National HIV/AIDS Control Project (NACP - III)” from India ministry of Health and successfully supplied and installed Blood Bank Refrigerators, -86°C ULT Freezers and -40°C Deep Freezers. 2013 2012 2011 2010 Haier Medical successfully won the bid of 20,930 units vaccine refrigerator from UNOPS (United Nations Program India Purchasing Agency). Haier won MOH tender of blood bank refrigerators and -86°C ULT freezers in Russia market. Haier Blood Transportation Box – HXC-80, won the bid of UNOPS India/NACO/BT B/35/2008, from India National AIDS Control Organization. Haier became the first China based company to be certified to ISO13485:2003. 2004 Haier was awarded with an order from the World Health Organization to supply 10,000 units of ice-lined refrigerators to India. This business marked Haier’s entry into the international market. 03 04 2014 Haier Biomedical inaugurated a new state-of –the art manufacturing facilities for high quality production of medical cold chain products. The world most energy-saving ULT Freezer was launched by Haier Bio-Medical. 1000 units HTC-60 were delivered to Ethiopia. Premium Products ULT Freezer 18 Pharmacy Refrigerator • World Leading Energy-efficient • New Appearance, more intelligent • Hrdrocarbon Refrigeration System • USB Data Port • Reliable Sample Protection • Electrically Heated Glass Door • Excellent Insulation Performance • Optional Printer • Multiple Alarms • Adjustable Shelves HYC-390/290 DW-86L728J/578J ULT Freezer 43 21 Under-counter Pharmacy Refrigerator • LCD Touch Screen • Under-counter Models, Offering Accessibility • Unique Inventory Management System • Electrically Heated Glass Door • World Largest Capacity • Optimized Refrigeration System • Global Most Energy-efficient • Drawers And Shelves Storage • Multiple Alarm Options 45 • Audible And Visible Alarm DW-86L959/729 Deep Freezer HYC-118A/118 31 Ice Lined Refrigerator • Double Door Design • WHO/PQS Approved • Double Capillary Tube • Large Capacity • Improved Door Seal • CFC-Free • Label Drawers • Stainless Steel Interior • Multiple Function Alarms • Ice-packs Built In HBC-340/110 DW-40L508/348 Blood Bank Refrigerator 31 Biological Safety Cabniet • Consistent Cabinet Temperature 4±1℃ • EN12469 & NSF Certificated • Microprocessor Control • Patent Intelligent Constant Air Velocity • Auto Defrost • LNS Green Energy-saving Mode • Optional Drawers or Blood Baskets • Unique Drop-down Front Glass Window • Multiple Alarm Options • Patented Technology of Air Flow Disruption HR1200-IIA2 HXC-358B 05 67 06 67 2014 NEW PRODUCTS Biomedical Preservation 11 Cryo Freezer 13 ULT Freezer 25 Cryogenic Supplies 31 Deep Freezer 41 Combined Refrigerator and Freezer 43 Pharmacy Refrigerator 53 Blood Bank Refrigerator WHO/PQS Certificated 63 Vaccine & Icepack Freezer 65 Ice-lined Refrigerator 67 SDD Vaccine Refrigerator 71 Walk-In Cold/Freezer Room Laboratory Equipment 07 75 Laboratory Equipment 81 Clean Bench 83 Liquid Nitrogen Container 89 CO2 Incubator 91 Lab Centrifuge 08 Cryo Freezer & ULT Freezer 09 10 -150°C Cryo Freezer Liquid Nitrogen Preservation System in Cryo Freezer Cryo Freezer(-140°C) LN2 Freezer System(-196 °C) DW-150W200 Model -150°C Cryo freezer, developed by Haier Medical and Laboratory Products Co.,Ltd provides a safer, more convenient and economical alternative long term storage method than LN2 refrigeration systems. By providing a storage environment that is about 20°C colder than the water recrystallization temperature, the freezer is suitable for storage of a variety of biological samples such as virus, erythrocytes, leukocytes, cutis, skeleton, sperm, oceanic products, special test materials and even electronic products for testing. It can be installed in institutions including blood banks, hospitals, epidemic prevention services, research institutes, and research laboratories. Technical Data Cabinet Type Chest Climate Class N Cooling Type Forced air cooling Defrost Mode Manual Refrigerant Performance Control CFC-Free Cooling performance(°C) -150 Temperature Range(°C ) -126~-150 Controller Microprocessor Display LED Power Supply(V/Hz) Temperature Control • Microprocessor control: Large LED display features a clear cabinet temperature display at an easy viewing angle and allows an adjustable range of -126°C to -150°C Refrigeration System • • • • Safety Control System • Alarm system: User programmable high and low temperature alarm set points, power failure, sensor error, extreme voltage, hot condenser, and extremely high ambient • Alarm types: audible buzzer and visible flashing • Protection functions: Settable pass codes for control panel, start-up delay, voltage compensation system • Properly grounded Optimized single stage refrigeration system Hermetically sealed system Environmentally safe refrigerants Permanently lubricated fan systems Electrical Data Dimensions Functions Large LED display for easy viewing Ambient range of 10 °C to 30°C LN2 back up system compatible Remote monitoring Smart condenser fans for energy saving Power(W) 2800 Electrical Current(A) 9 Capacity(L/Cu.Ft) Other Features • • • • • 380/50 Accessories 200/7.1 Net/Gross Weight(approx) 315/385(kg) 694.5/848.8(lbs) Interior Dimension(W*D*H) 667*462*650(mm) 26.3*18.2*25.6(in) Exterior Dimension(W*D*H) 1570*850*1060(mm) 61.8*33.5*41.7(in) Packing Dimension(W*D*H) 1710*985*1195(mm) 67.3*38.8*47.0(in) Container load (20'/40'/40'H) 6/13/13 High/Low Temperature Y Remote Alarm Y Hot Condenser Y Power Failure Y High/Low Voltage Y Sensor Error Y Low Battery Y High Ambient Temp Y Caster Y Foot Y Test Hole Y -/2 Shelves/Inner doors 11 12 Cryo Freezer & ULT Freezer Biomedical Biomedical -86°C ULT Freezer 4 Individual Removable Foam Inner Doors This product is specially designed and manufactured for long term storage of various biological products, including viruses, germs, erythrocytes, leucocytes and cutis. Applications can be found in blood banks, hospitals, epidemic prevention services, and research institutes, laboratories in electronic and chemical plants, biological engineering institutes and marine fishery companies. • 4 individual inner doors can be opened independently to minimize frost buildup inside the chamber. • Unique door seal design for the minimum loss of cold temperature during a door opening. • Compatibility with existing racking system from competitors. • Stainless Steel handle to ensure the door open conveniently even in the case of frost. Operating status display Excellent Doors Seals • 5 gasket seal , 4 seals for out door, 1 seal for inner door which provides maximum protection against thermal intrusion. Display for working temperature, setting temperature,high-alarming temperature, low-alarming temperature,password setting, and codes error Eye-level controls for quick and easy programming and viewing Audio/visual alarm Silencing sound alarm Microprocessor control panel and digital display Malfunction detection Adjusting key Ambient temperature display Selecting function Circular- chart Recorder(Optional) • Front-mounted. • For independent temperature monitoring. Pressure Equalization Port • Heated port with spring-assisted mechanism to prevent icing on the vent. • Allows the freezer door to be opened shortly after adding samples. Voltage display Alarm Alarm Triggering Condition High Temperature Temperature reaches the warm alarm limit Low Temperature Temperature reaches the low alarm limit Power Failure Equipment loses power Door Open Door open period exceeds 5 mins 1.Main cabinet temperature control sensor fails DW-86L728J 2.Condenser sensor fails 3.Ambient sensor fails 4.Heat exchanger sensor fails High Efficiency Refrigeration Components 5.Heat exchanger temperature fails • Industrial grade hermetically sealed compressors, ultra low noise under cascade cooling system. • High efficiency coalescent oil separator ensures no oil entering. • Energy efficient fan design. • Unique CH refrigeration system is optimized to provide maximum efficiency in even the most extreme ambient conditions. 13 Low Battery Two sample ports on back for temperature monitoring conveniently. Hot Condenser High Ambient Temperature Battery capacity runs low or battery switch is not turned on 1. Condensers filter element is clogged 2. Ambient temperature is too high Ambient temperature exceeds 32°C 14 Cryo Freezer & ULT Freezer Probe Failure Performance and Features Biomedical Field proven reliablity Safety Installiation & Application Heat exchange circulation system • Unique insulated inner door design for four separate storage compartments to minimize frost buildup inside the chamber • Specialized control system design for a well-balanced operation of cascade refrigeration system • Positive field proven reliability record • Malfunction alarms including high and low temperature, power failure, sensor error, clean -filter, and extremely high ambient • Capable of producing two types of alarm outputs: audible buzzer and visible flashing light • Multiple built-in system protection features including user-settable protection code for controls, user settable delay to start, voltage compensation system, and protection against extreme high voltages • Door open feature standard and USB port for temperature data downloading standard on upright models • Remote alarm contacts • Wide range operating voltage system from 185V to 260 V designed to allow units installed in areas with poor voltage condition • Suitable for 10°C to 32°C ambient temperature • Input voltage and ambient temperature shown simultaneously for ease of monitoring environmental conditions • Robust door latch designed for secure door closing • Compact casters for ease of maneuvering Filter • Filter for refrigerant to protect system from the water and other entering Capillary tube for high stage • High temperature refrigerants flow into the evaporator from the Capillary tube • Specialized refrigeration system design using whisper quiet fan and compressors • Freezer chassis designed to absorb vibration and sound High stage condenser • Extra-large air cooled condenser dissipates product heat content efficiently. • Unique door seal design for the minimum loss of cold temperature during a door opening • High performance VIP insulation panels to minimize cabinet heat gain and to improve temperature stability • Patented cabinet insulation system designed for optimal performance of cold storage temperature and minimal frost buildup • Unique design of independent insulated inner door systems for independent access of storage space to provide the maximum protection of stored samples Energy saving Key design features • Microprocessor-controlled system designed for controllable range of -40°C to -86°C for cabinet space with 1°C increment • Large LED display for cabinet temperature, set temperature, ambient temperature, and input voltage • Settable high temperature and low temperature alarms • Automatic clean-filter alarm and sensor error alert • Adjustable storage shelf height • Optional temperature recorder, storage racks and storage boxes 15 Low stage Evaporator • The close contact design between the evaporating tube and the inner cabinet increases the heat conducting efficiency Ultra low noise compressor • Compressor provides reliable performance with ultra low noise • Specially designed low stage evaporator yields excellent temperature uniformity and recovery after loading and door opening. • Both high and low stage compressors are industrial grade hermetically sealed compressor designed for low temperature application. Sound level is extremely low. Heat exchanger system • Heat exchanger between the high and low temperature stage in the system Temprite oil separator • Temprite oil separator can effectively separate oil and water so as to improve the refrigeration performance 16 2014 Cryo Freezer & ULT Freezer Low sound level Capillary tube for low stage • Low temperature refrigerants flow into the evaporator from the Capillary tube CO2 Backup System Biomedical ULT Freezer Haier’s next generation ULT freezer DW-86L728J is particularly designed for energy savings. It consumes the least amount of energy for the class of large ULT freezers. This new model uses environmentally safe hydrocarbon refrigerants and high efficiency fan motors to maximize the cooling ability of the system and reduce energy consumption. While providing sample safety, the new freezer design makes energy savings possible for laboratories. Advantage • Small footprint, light and easy for installation; • User adjustable temperature setting • Simple to program and operate • Flexible – Can be installed on any ULT freezer, which has a port hole Safety • Liquid CO2 test button design allows end user to test the system is working; • Low CO2 alarm system - alerts end user when liquid CO2 bottle is running out therefore insuring the safety of their samples Reliability • Stainless steel covering, more elegant; • Stainless steel input pipe design, allows for flexibility and ease of cylinder positioning • Durable battery lasts up to 48 hours. Technical Data Performance Control Electrical Data Model Cabinet Type Climate Class Cooling Type Refrigerant Cooling performance(℃) Temperature Range(℃) Controller Display Power Supply(V/Hz) Power(W) Electrical Current(A) Net/Gross Weight(approx) Dimensions Exterior Dimensions(W*D*H) Packing Dimensions(W*D*H) Functions Accessories Others CO2 Margin Insufficient Alarm Low Battery Alarm Sensor Error Alarm Main Power Off Alarm Charge Indicator CO2 Injection Test Button Foot Certificate HBX-IC Horizontal N Direct cooling CO2 -70 -40- -70 Thermostat LED 220~240/50 20 0.15 10.5/13(kg) 23.1/28.7(lbs) 200*400*160(mm) 7.8*15.7*6.3(in) 370*530*330(mm) 14.6*20.9*13(in) Y Y Y Y Y Y 4 CE,UL Advantages • World leading energy-efficient, 10.5* kwh/day for DW-86L728J and 8.5* kwh/day for DW-86L578J • Hrdrocarbon refrigeration system • Slim cabinet design • Reliable sample protection • Malfunction alarms • Excellent insulation performance *( Data is validated by National Center Of Safety Quality Supervision And Testing For Electronic & Electrical Products) ”A proven solutions partner “Marrow DonorProgra (NMDP) Cryo Freezer & ULT Freezer Hundreds of -86 °C ultra low temperature freezer and the cold chain equipment monitoring and control system solution for NMDP. Haier water-cooled ULT Freezer in SAHMRI, Australia The first water-cooled ULT freezer project of Haier biomedical in overseas market and the products were highly evaluated “Haier water-cooled ULT freezer is the best in the world!" 18 Biomedical Extended Pull-up Time During A Power Failure Superior • Special V.I.P(Vacuum Insulation Panel) design with extra insulation factor cuts down heat loss to cabinet by 25% • High efficiency hrdrocarbon refrigerant based refrigeration system increases the efficiency by 45% than previous model • Four individual insulated inner door to keep the cold air inside • Pressure equalization port provides superior air flow making it possible to drastically reduce the stress on the freezer • Low noise 50dB(A) (reference data) • Pull-up time measures the time taken for temperature to rise up (from -80°C to -50°C ) at 25°C ambient when the power is interrupted • Haier has the best pull-up time among the ULT freezers compared with competitors’ largest volume product DW-86L728J Pull-up test at 25°C ambient 40 30 20 10 0 Alarms (visual and audible) • Excellent temperature uniformity for an exacting sample storage requirement • High efficiency and reliability cooling fans ensure energy savings and long term storage safety Temperature (°C) Safety • • • • • • • • • -10 Adjustable High/Low temperature alarm Sensor error Low battery Door open Power failure Probe failure Hot condenser High ambient Remote alarm contact -20 -30 -40 -60 -70 -80 -90 -100 0 50 100 150 200 250 300 350 400 450 500 550 600 650 Time (Min) Global Most Energy Efficiency 307 (min) 220 (min) Haier Brand T DW-86L728J 184 (min) Brand N 150 (min) Brand P Electricity charge of a 700-liter ULT Freezer Haier DW-86L728J Electricity Charge for ten years compared with other bands with similar capacity Ambient Temperature Electricity Charge (1year) Electricity Charge (5year) Electricity Charge (10year) DW-86L728J 10.5* 25°C € 1,724.6 € 8,623.1 € 17,246.3 Brand P 11.5 22~26°C € 1,888.9 € 9,444.4 € 18,888.8 Brand N 15.2 23°C € 2,496.6 € 12,483.0 € 24,966.0 €80,000.0 Brand T 19.0 25°C € 3,120.8 € 15,603.8 € 31,207.5 €70,000.0 Notes:*Typical data - individual units may vary and power consumption will depend on loading and operating conditions. Freezer set-point -80°C, ambient temperature 25°C, unloaded, 220~240V 50Hz power supply €90,000.0 • Compared with Brand P, Haier DW86L728J will help you to save €1,642.5 electricity charge in 10 years • Compared with Brand N, Haier DW86L728J will help you to save €7,719.7 electricity charge 10 years • Compared with Brand T, Haier DW86L728J will help you to save €13,961.2 electricity charge 10 years €90,000.0 €60,000.0 • The new Eco-friendly Haier ULT freezer is the most energy-efficient one in the world which is designed to help you save energy. Average Power Consumption (Kwh/day) €50,000.0 €40,000.0 20 €30,000.0 15 UP TO €20,000.0 45% €10,000.0 10 €0 5 (10.5) (19.0) (15.2) (11.5) Brand T Brand N Brand P 0 Haier 1 2 3 4 5 6 7 8 9 10 (Year) *The calculation of electricity reference to the German average industrial electricity Brand T Brand P Brand N Haier DW-86L728J Cryo Freezer & ULT Freezer Power Consumption (Kwh/h) Model ULT Freezer Biomedical Two Modes Selection Haier to release the largest ultra-low temperature storage freezer with touch screen control in the global market. For customers who require the strictest tolerances, our high performance mode provides the tightest temperature uniformity. For most applications, our energy savings mode offers excellent temperature control, plus up to 13.5% savings on energy usage. UNIQUE INVENTORY MANAGEMENT SYSTEM(IMS) • High-Performance Mode Designed with GMP applications in mind. Outstanding temperature uniformity and peak variation from setpoint • Energy-Savings Mode Excellent temperature uniformity Up to 13.5% energy savings over high-performance mode 18.5 Energy Efficient 16 Haier energy consumption is the lowest of all manufactures' largest capacity ULT Freezers 21.8 Layered display for sample storage, clear at a glance, easier to manage Haier DW-86L959 Brand T High performance 16 Energy savings 24.6 Brand P Average Power Consumption (KWh/day) Extended Pull-up Time During A Power Failure • Pull-up time measures the time taken for temperatureto rise up (from -80°C to -50°C ) at 32°C ambient when the power is interrupted • Haier has the best Pull-up time among the ULT freezers compared with competitors’ largest volume product DW-86L959 Haier DW-86L959 Brand P Pull-up test at 32°C ambient 40 Temperature(°C) USB Interface Access Security Swiping Card The enhanced security card control can prevent discretional opening , thus protect your sample records. 21 Message and notepad function to transmit the information conveniently 0 -20 -40 -60 -80 -100 0 200 400 600 800 1000 1200 260 Time(Min) 22 247 120 Cryo Freezer & ULT Freezer Brand T 20 -86°C ULT Freezer Biomedical Specification Technical Data DW-86L338 DW-86L388A DW-86L486 DW-86L490 DW-86L628 DW-86L828 DW-86L728J DW-86L729 DW-86L959 DW-86W100 DW-86W420 Upright Upright Upright, double door Upright Upright Upright Upright Upright Chest Chest N N N N N N N N N Climate Class N Upright N Cooling Type Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Direct cooling Defrost Mode Manual CFC-Free 50 Manual CFC-Free 50 Manual CFC-Free 49 Manual CFC-Free 49 Manual CFC-Free 49 Manual CFC-Free 50 Manual HC 50 Manual CFC-Free 49 Manual CFC-Free 49 Manual CFC-Free 49 Manual CFC-Free 50 Refrigerant Noise(dB) Cooling Performance performance(°C) Temp Range(°C) -86 Controller Control LED Display LED LED -40~-86 Microprocessor LED -86 -40~-86 LED Power Supply(V/Hz) Electrical Data 220~240/50 220/60 220~240/50 220~240/50 220/60 115/60 220~240/50 220/60 220~240/50 220/60 115/60 Power(W) 1200 1200 1200 1000 1000 900 1100 1000 1000 1200 1100 7.5 6 8 9 5.5 18 6.5 6.5 9 18 7 Electrical Current(A) 490/17.3 Capacity(L/Cu.Ft) 628/22.2 338/11.9 486/17.1 388/13.7 295/335 238/278 290/310 301/323 255/286 Net/Gross Weight (kg) (approx) (lbs) 524.7/612.9 650.4/738.5 663.6/712.1 562.2/630.5 639.3/683.4 Interior Dimension (W*D*H) Dimensions Exterior Dimension (W*D*H) (mm) 465*630*1165 465*630*1310 (in) 32.0*35.2*72.7 32.0*35.2*78.0 Packing Dimension (W*D*H) LED 220~240/50 1000 7.5 959/33.9 450/485 992.1/1069.2 100/3.5 138/160 304.2/352.7 420/14.8 310/357 683.4/787.1 870*716*1310 34.3*28.2*51.6 1016*716*1310 40.0*28.2*51.6 470*450*480 18.5*17.7*18.9 1367*462*652 53.8*18.2*25.7 1296*998*1980 51.0*39.3*78.0 769*825*1120 2130*870*1020 30.3*32.5*44.1 83.9*34.3*40.2 1355*1100*2130 835*860*1235 2300*970*1164 760*630*1310 29.9*24.8*51.6 1035*900*1980 37.2*35.4*78.0 33.9*35.4*78.0 40.7*35.4*78.0 1145*980*1980 45.1*38.6*78.0 (mm) 875*970*1990 875*970*2130 990*985*2130 920*990*2130 1090*960*2130 1190*1035*2145 (in) 34.5*38.2*78.3 34.5*38.2*83.9 38.9*38.8*83.9 36.2*38.9*83.9 42.9*37.8*83.9 46.9*40.7*84.4 44.3*42.3*83.9 44.3*43.7*83.9 53.3 *43.3*83.9 32.9*33.9*48.6 90.6*38.2*45.8 12/24/24 12/24/24 12/24/24 8/20/20 10/20/20 10/20/20 8/16/16 12/24/48 6/12/24 Y Y Y N/A Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N/A N/A Y Y Y Y Y Y 1125*1075*2130 1125*1100*2130 Container load (20'/40'/40'H) 12/24/24 12/24/24 High/Low Temp Y Y Y Y Y Y Hot Condenser Y Y Y Y Y Y Y Y Y N/A Y Y Y Y Y N/A Y Y N/A Door Ajar Y Y Y Y Y Y Y Y Y Y Y Y Y Y N/A Y Y Y Y Caster Y Y Y Y Y Foot Y Y Y Y Y Y Y,2 Y,2 Y,2 Y Y 3/2 3/4 Y 3/4 Y 3/2 Y 3/4 Y Y Y Y Y Y Y Y 3/4 3/4 3/4 3/4 -/1 -/3 Temp Recorder N/A Y Optional N/A Y Optional Y Y Optional N/A Y Optional Y Y Optional Y Y Optional Y Y Optional Y Y Optional Y Y Optional N/A Y Optional N/A Y Optional Rs232/485 Interface Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional CO2 Backup System Optional LN 2 Backup System Certificate Optional CE,UL Optional Optional CE Optional Optional CE,UL Optional Optional CE Optional Optional CE,UL Optional Optional CE,UL Optional Optional CE Optional Optional CE Optional Optional CE Optional Optional CE,UL Optional Optional CE High/Low Voltage Sensor Error Low Battery High Ambient Temp Test Hole Shelves/Inner doors Accessories USB Interface Remote Alarm Others LED 220~240/50 1000 10 590*630*1310 23.2*24.8*51.6 860*900*1980 590*630*1310 23.2*24.8*51.6 (mm) 812*893*1846 812*893*1980 945*900*1980 (in) 18.3*24.8*45.9 18.3*24.8*51.6 Power Failure Functions LED 220~240/50 220/60 1200 1200 9 9 828/29.2 380/410 837.8/903.9 Microprocessor LED Touch Screen LCD Touch Screen LCD 220~240/50 115/60 220~240/50 220~240/50 1200 1300 650 650 7.5 12 9 8 Y Y Y Y Cryo Freezer & ULT Freezer Model Cabinet Type Biomedical PP Freezer Boxes PC Freezer Boxes Features Features • For easy inventory management of cryogenic vials used • For easy inventory management of cryogenic vials used in tissue culture, pharmaceutical research and other biotechnology labs in tissue culture, pharmaceutical research and other biotechnology labs • Boxes are designed with international standard size, which can fit all of the standard cryogenic vials and freezer racks • Store in mechanical freezers • Boxes are vented, allowing rapid cooling of contents and full drainage • Made of polypropylene for use with temperature from -80ºC to 121ºC • Chemically resistant to alcohols and mild organic solvents • Store in mechanical freezers or liquid nitrogen • Boxes are vented, allowing rapid cooling of contents and full drainage • Made of tough polycarbonate for use with temperatures from -196°C to 121°C • Chemically resistant to alcohols and mild organic solvents HBB-281-C Box Design Ordering Information Cat # Box Design Well Material HBB-281-C 81-well PC HBB-200-C 100-well PC • 9x9 well storage (81-well total) or 10x10 well storage (100-well total) • With 5 assorted colors: clear, pink, green, blue, and yellow for better color-coding • Holds 0.5ml, 1.5ml or 2.0ml microtubes and cryogenic vials • HBB-200-P box with numeric identification on each column for quick sample identification Ordering Information Cat # Well HBB-281-P 81-well HBB-200-P 100-well Material PP PP Color Height Dimensions Unit Assorted Colors (Pink,Yellow, Blue, 132*132*53(mm) 2inch Green,Clear 5.2*5.2*2.1(in) mixed) Assorted Colors (Pink,Yellow, Blue, 2inch 132*132*53(mm) 5.2*5.2*2 .1(in) Green,Clear mixed) 5 colors/ bag, 4 bags/ box, 20sets/ case 5 colors/ bag, 4 bags/ box, 20sets/ case HBB HBB-200-C 200 C Color Height Dimensions Unit Assorted Colors(Red, 132*132*53(mm) 2inch Yellow, Blue, 5.2*5.2*2.1(in) Greenmixed) Assorted Colors(Red, 132*132*53(mm) 2inch Yellow, Blue, 5.2*5.2*2.1(in) Green mixed) • 9x9 well storage (81-well total) or 10x10 well storage (100-well total) 4 colors/bag, 6 bags/box, 24 sets/case • Boxes are designed with international 4 colors/bag, 6 bags/box, 24sets/case • • • Product Parameter Cat # Description A B C D E F G HBB-281-C Box 132.0 12.2 35.0 30.0 26.0 16.5 132.0 HBB-200-C Box 132 129.7 130.7 12.6 31.3 26.4 4.9 • standard size, which can fit all of the standard cryogenic vials and freezer racks With 4 assorted colors: red, yellow, green, and blue for better color-coding Holds 0.5ml, 1.5ml or 2.0ml microtubes and cryogenic vials 81-well box features a removable lid includes a numbered grid for orientation 100-well box with numeric identification on each column for quick sample identification (Dimensions=mm) Cat # Description A B C D HBB-281-P Box 76.0 12.2 35.0 30.0 HBB-200-P Box 132 129.7 130.7 12.6 E F G 26.0 16.5 76.0 31.3 26.4 4.9 (Dimensions=mm) Easy for sample organization Numbered grid for orientation Each box includes drain holes and air vents in the lid and bottom to minimize condensation HBB-200-C Cryogenic Supplies Product Parameter Biomedical Cryogenic Vials/Racks Cryogenic Vials Features • Ultimate in applications from sample storage in ultralow temperature freezer to boiling applications • Polypropylene material makes these screw cap tubes perfect for almost every long term storage application • Superior clarity and phenomenal strength • Universal screw threads for use • Tubes fit most common rotors • Autoclavable to 121°C and freezable to -86°C • Tubes are screwed with caps and are gamma radiation sterilized • Tubes fit standard 1-inch and 2-inch, 81well and 100-well freezer boxes Writing area for easy marking Black graduations provide an easy volume reference Tubes with ribs lock in place enable singlehanded operation. All sterilized Cryogenic Vials are packed with caps attached and include o-rings. Ordering Information Cat # Volume Bottom Writing Area Sterile HBT-020-C-S 2.0ml SelfStanding Yes Unit 50 Sets/bag, 500 Sets/ pack,2000 Sets/case Yes Product Parameter Cat # Description A B C D E HBT-020-C-S 2.0ml 47.5 O.D.9.6 8.3 46.5 9.4 (Dimensions=mm) FEATURES • Sliding drawer and sliding access type Design for choose. • Fully functional Freezer Rack is constructed of corrosion-resistant stainless steel • Sliding Drawer Freezer Racks include handles Vertical Type Freezer Racks Cryogenic Supplies for easy removal off the shelf • Optimize Freezer Storage Space • Ideal for storage of 2” standard size boxes • Fits most standard upright freezers • Available with Sliding Drawer, Frame Type and Deep Freezer Biomedical -40°C Deep Freezer -40°C Deep Freezer(Double Doors Type) The -40°C deep freezer offers a large capacity storage space with fast temperature performance. Integrated design of cold shelf and evaporator provides additional refrigeration efficiency. This product is designed to store vaccines, blood plasma, and many other biological materials. Installations can be found in research institutions and clinical sites in life science, electronic testing and medical markets. Haier ‘s next generation low temperature storage freezer, DW-40L348, is designed based on the original work horse platform of DW-40L508. The new freezer model operates with two capillary tubes and is equipped with dual gaskets to improve the temperature uniformity through the chamber drastically. It can be installed to satisfy tougher application requirements in universities, research institutions and blood banks. Reliability and Key Features • Rated for -40°C at 32 °C ambient • Rapid cooling with shelf evaporator • Improved temperature uniformity with dual capillary tube design at the range of -20 °C to -40°C • Improved door seal design with two gaskets maintains cabinet temperature more efficiently • Frost buildup is reduced • Insulation thickness is 90 mm for additional robustness, less power consumption and more temperature retaining ability • Drawer design maximizes storage space. One unit can hold 360 bags of 230 ml blood bags Safety • Multiple malfunction alarms include high/low temperature, power failure, sensor error, low battery, high/low ambient temperature • Two types of alarms: buzzer and flashing light Ergonomic Design Control panel Drawer Shelf Handle Deep Freezer • LED digital display for clear observation • Double door design with independent locks reduces air leakage to ensure temperature stability and lower power consumption • Tracks to label drawers for product identification -40°C Deep Freezer (Upright) -40°C Deep Freezer (Chest) Reliability and Key Features Key Features • High efficiency low temperature compressor with known field reliability, • Chemically stable, CFC-free, commercially available and environmentally safe refrigerant • Permanently lubricated cooling fan for safety and longevity , high density insulation foam for stable and long term storage temperature • Optimized refrigeration system designed to maximize cooling effect and temperature uniformity • Microprocessor control, digital display, adjustable temperature range: -20°C~-40°C • LED digital display for clear observation • Wide voltage tolerance design with applicable voltage range of 198~252 V/AC Microprocessor control, adjustable tempe rature range :-20°C to -40°C LED digital display and increment at 0.1°C Permanently lubricated cooling fan for saf ety and longevity Rapid cooling with shelf evaporator Removable double outer door seal design, good sealing effect and energy saving Ergonomic Design USB Data logging and temperature recorder are optional Padlock design and stainless steel cylinder Tracks to label drawers for product identification Safety • Multiple malfunction alarms to detect high / low temperature, sensor error, and power failure • Two types of alarm indications: audible buzzing and visual flashing light Safety Multiple malfunction alarms include high/low temperature, sensor error, power failure, high ambient temperature, low battery Alarm Types: buzzer, flashing light, remote alarm Ergonomic Design • Door lock for storage safety • Standard ø40 access port for testing instrumentation except model DW40W380 • Corrosion proof cabinet interior design • Suitable for a variety of storage baskets Liner Electronic Thermostat DW-40W380 Pull-up test at 32°C ambient 0 0.25 0.5 0.75 1 1.25 1.5 1.75 2 2.25 2.5 2.75 3 Time (H) 3.25 3.5 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 Time (H) 5 5.5 6 6.5 7 7.5 Deep Freezer Temperature (°C) DW-40W380 Pull down test at 32°C ambient Temperature (°C) Biomedical -40°C Deep Freezer Model Technical Data Performance Control Electrical Data Cabinet Type Climate Class Cooling Type Defrost Mode Refrigerant Noise(dB) Cooling per forman ce(°C) Temperature Range(°C) Controller Display Power Supply(V/Hz) Power(W) Electrical Current(A) Capaci ty(L/Cu.Ft) Net/Gross Weight (approx) Interior Dimension (W*D*H) Dimensions Exterior Dimension (W*D*H) Packing Dimension (W*D*H) Container load (20'/40'/40'H) Functions DW-40L92 Upright N Direct cooling Manual CFC-Free DW-40L262 Upright N Direct cooling Manual CFC-Free DW-40L348 DW-40L508 DW W-40L 0 508 Upright, double door N Direct cooling Manual CFC-Free Upright, double door N Direct cooling Manual CFC-Free DW-40L626 Upright N Direct cooling Manual CFC-Free 40 -40 -10~-40 Microprocessor LED 44 -40 -10~-40 Microprocessor LED 45 -40 -20~-40 Microprocessor LED 45 -40 -20~-40 Microprocessor LED 49 -40 -20~-40 Microprocessor LED 220~240/50 200 0.5 92/3.3 220~240/50 115/60 340 600 3.9 7.5 262/9.3 220~240/50 360 2.9 348/12.3 46/51(kg) 88/93(kg) 137/145(kg) 490/17.3 170/200(kg) 626/22.1 298/314(kg) 101.4/112.4(lbs) 465*440*645(mm) 194.0/205.0(lbs) 480*465*1430(mm) 302.0/319.7(lbs) 535*607*1228(mm) 374.8/440.9(lbs) 685*650*1228(mm) 18.3*17.3*25.4(in) 597*610*860(mm) 18.9*18.3*56.3(in) 657*685*1665(mm) 21.1*23.9*48.3(in) 750*840*1860(mm) 23.5*24.0*33.9(in) 659*699*934(mm) 25.9*27.5*36.8(in) 54/108/108 DW-40W255 Chest N Direct cooling Manual CFC-Free ≦45 -40 -20~-40 Microprocessor LCD DW-40W380 Chest N Direct cooling Manual CFC-Free ≦45 -40 -20~-40 Microprocessor LCD 220~240/50 410 4.2 220~240/50 208~230/60 550 550 5.1 5.1 100/3.5 43/46(kg) 255/9.0 70/82(kg) 380/13.4 82/89(kg) 657.0/692.2(lbs) 760*630*1310(mm) 94.8/101.4(lbs) 500*385*625(mm) 154/180.8(lbs) 1040*430*605(mm) 180.8/196.2(lbs) 1376*457*625(mm) 29.5*33.1*73.2(in) 27.0*25.6*48.3(in) 895*840*1860(mm) 35.2*33.1*73.2(in) 29.9*24.8*51.6(in) 1035*900*1980(mm) 40.7*35.4*78.0(in) 19.7*15.2*24.6(in) 680*600*805(mm) 26.8*23.6*31.7(in) 40.9*16.9*23.8(in) 1243*633*838(mm) 48.9*24.9*33.0(in) 1550*633*838(mm) 61.0*24.9*33.0(in) 815*945*2040(mm) 32.1*37.2*80.3(in) 965*945*2040(mm) 38.0*37.2*80.3(in) 1072*954*2130(mm) 42.2*37.6*83.9(in) 735*645*855(mm) 28.9*25.4*33.7(in) 1310*750*880(mm) 51.6*29.5*34.6(in) 1630*755*880(mm) 64.2*29.7*34.6(in) 24/48/48 14/28/28 12/24/24 12/24/24 54/108/162 24/54/81 18/42/63 3.1 25.9*27.0*65.6(in) 732*745*1756(mm) 774*719*1920(mm) 28.8*29.3*69.1(in) 30.5*28.3*75.6(in) 220~240/50 208~230/60 430 430 2.9 2.9 220~240/50 700 8 DW-40W100 Chest N Direct cooling Manual CFC-Free ≦45 -40 -20~-40 Microprocessor LCD 220~240/50 255 5.0 115/60 255 5.0 54.2*18.0*24.6(in) High/Low Temperature Remote Alarm Hot Condenser Y Y Y Y Y Y Y Y N/A N/A N/A N/A Y N/A Y N/A Y Y N/A N/A N/A N/A N/A N/A Power Failu re High/Low Voltage N/A N/A N/A N/A Y N/A Y N/A Y N/A N/A N/A N/A N/A N/A Sensor Error Low Battery High Ambient Temp Y Y N/A N/A N/A N/A Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Accessories Caster Foot Test Hole Drawers/Inner doors USB Interface Temperature Recorder N/A 3/N/A N/A Y 7/N/A N/A Y 12/Optional Optional Y 10/Optional Optional 3(Shelves)/4 N/A Optional Others Certificate CE CE CE CE / / Y Y Y Y Y Y N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Y / N/A Y / N/A N/A / N/A N/A N/A N/A CE CE CE N/A N/A Deep Freezer Biomedical Biomedical Model Technical Data DW-25L300 Cabinet Type Upright Climate Class N Refrigerant CFC-Free 300/10.6 Functions High/Low Temperature Y Sensor Error Y Deep Freezer 88/93(kg) 194/205(lbs) Combined Refrigerator and Freezer Biomedical Refrigerator & Freezer Combination, Separate Controled Approved by Uzbekistan MOH • 520 units combined refrigerator and freezers(model: HYCD-282A) was approved by Uzbekistan MOH. Excellent Performance • Adjustable refrigerator compartment temperature range: 2°C to 8°C • Adjustable freezer compartment range: -20°C to -40°C light light light Key Function • • • • • • • • USB port for data download Capable of recording temperature data for up to one month automatically Independent display for refrigerator section and freezer section Optional remote alarm and monitor via internet Drawers with divided compartments Shelves with divided sections Multiple alarms to detect malfunctions Multi-malfunction alarms, precautionary alarm Model Cabinet Type Climate Class Technical Data Performance Control Electrical Data Cooling Type Defrost Mode Refrigerant Noise (dB) Cooling performance(℃) Temperature Range (℃) Controller Display Power Supply(V/Hz) Power(W) Electrical Current(A) Capacity(L/Cu.Ft) Net/Gross Weight(approx) Dimensions Interior Dimensions(W*D*H) Exterior Dimensions(W*D*H) Packing Dimensions(W*D*H) HYCD-282 HYCD-282A Functions Accessories Others Container load (20'/40'/40'H) High/Low Temperature Remote Alarm Power Failure Sensor Error Low Battery High Ambient Temp Caster Foot Test Hole Shelves/Drawers USB Interface Certificate HYCD-282 Upright N Refrigertor:Forced air cooling Freezer: Direct cooling Manual CFC-Free 43 Freezer:-40 2~8/-20~-40 Microprocessor LED 220~240/50 400 2.8 Refrigerator:185/6.5 Freezer: 97/3.4 145/160(kg) 320.0/352.7(lbs) Refrigerator: 605*510*720(mm) Freezer: 515*465*440(mm) Refrigerator: 23.8*20.0*28.3(in) Freezer: 20.3*18.3*17.3(in) 736*660*1810(mm) 29.0*26.0*71.3(in) 774*719*1920(mm) 30.5*28.3*75.6(in) 21/45/45 Y Y Y Y Y Y Y Y Y 3/2 Y CE HYCD-282A Upright N Refrigertor:Forced air cooling Freezer: Direct cooling Manual CFC-Free 43 Freezer:-40 2~8/-20~-40 Microprocessor LED 220~240/50 208-230/60 400 400 2.8 2.8 Refrigerator:185/6.5 Freezer: 97/3.4 145/160(kg) 320.0/352.7(lbs) Refrigerator:605*510*720(mm) Freezer: 515*465*440(mm) Refrigerator: 23.8*20.0*28.3(in) Freezer: 20.3*18.3*17.3(in) 736*660*1810(mm) 29.0*26.0*71.3(in) 774*719*1920(mm) 30.5*28.3*75.6(in) 21/45/45 Y Y Y Y Y Y Y Y Y 3/2 Y CE Combined Refrigerator and Freezer Specification Pharmacy Refrigerator Biomedical Pharmacy Refrigerator Medical Refrigerator for Pakistan Aids The Haier pharmacy refrigerators are suitable for installation in drug stores, pharmaceutical companies, hospitals, epidemic prevention centers, and clinics. • 1000 units pharmacy refrigerator (model: HYC-360) was successfully provided for the tender of China Ministry of Commerce for supporting Pakistan Poliomyelitis Prevention Project in 2013. • 750 units pharmacy refrigerators was successfully approved by Philippines MOHFW in 2014. Reliability and Key Features Microprocessor control panel and digital display Permanently lubricated condenser fan motor Locks • High efficiency specialty compressor with known field reliability • Permanently lubricated cooling fan for safety and longevity • Forced-air cooling with optimized air distribution system designed to achieve maximum temperature uniformity and stability • Optimized refrigeration system design for more effective cooling and speedy recovery • Temperature variation within ± 3°C • Adjustable temperature range 2~8°C • Microprocessor control, digital display, and temperature adjustment with an increment of 0.1°C • Large digital display screen • Wide voltage tolerance suitable for unstable voltage supply • Designed for ambient temperature 10~32°C with humidity below 75% Safety • Equipped with a complete temperature alarm system featuring audible buzzer and visible flashing light • Capable of alerting failures due to high and low temperature, sensor error, door ajar, remote alarm, power failure and low battery Hermetically sealed compressor Test hole Door handles Ergonomic Design • Optimized space utilization design with multi-level and adjustable shelf height to accommodate storage requirement of pharmaceutical products of various kinds • Safety lock to prevent unauthorized access • Caster design and leveling legs • Interior light Dual-pane glass door design, convenient and aesthetic Pharmacy Refrigerator Dual lockable caster design Biomedical Pharmacy Refrigerator Technical Advantages The updated Haier Pharmacy refrigerator, more professional, more intelligent and more stable. • Accurate temperature control technology to make the temperature maintain 2~8 °C and increment at 0.1°C • Improved user interface with additional features include data USB port • Oversized air–cooled condenser improves the robustness of the refrigeration system reliability and refrigeration efficiency Optional Printer Display Panel Lock USB Port Ergonomic Design • The new improved data storage management system is completed with a USB data port for downloading temperature data. Traceability of temperature performance is easily maintained • Heated double-pane glass door allows a clear display of stored products without condensation at 32°C and 85% relative humidity condition • LED interior light saves energy and provides bright lighting for viewing • Drawers and shelves with optional label holders meet demands of product archiving and retrieving Safety Test Hole Evaporator Fan • Microprocessor control, digital display, temperature uniformity within 3°C • Malfunction alarms include high/low temperature, door ajar, sensor error, power failure, remote alarm interface. HYC-390 Pull down test at 25°C ambient HYC-390 Pull-up test at 25°C ambient Padlock Adjustable Shelf 30 60 Time (min) Electric Heating Glass Door 90 120 0 15 30 45 60 Time (min) Adjustable Foot Caster HYC-390 Pharmacy Refrigerator Sealing Strip Biomedical Under-counter Pharmacy Refrigerator Precision Constant Temperature, Exquisite Installation The first Under-counter pharmacy refrigerator in China, ultra low noise design, safety lock, perfect alarm system, safety protection. Reliability and Key Features • High efficiency specialty compressor with known field reliability • Permanently lubricated cooling fan for safety and longevity • Forced-air cooling with optimized air distribution system designed to achieve maximum temperature uniformity and stability • Optimized refrigeration system design for more effective cooling and speedy recovery • Temperature variation within ±3°C • Adjustable temperature range 2 ~8°C • Microprocessor control, digital display, and temperature adjustment with an increment of 1 °C • Designed for ambient temperature 10~32°C with humidity below 60% • Equipped with a complete temperature alarm system featuring audible buzzer and visual flashing light • Capable of alerting failures due to high and low temperature, sensor error, door ajar,power loss Ergonomic Design • Interior LED light • Safety lock to prevent unauthorized access Pharmacy Refrigerator Safety Pharmacy Refrigerator Biomedical Specification Climate Class Technical Data Cooling Type Deforst Mode Refrigerant PerformanceNoise(dB) Control Tmt. Range( °C) Controller Display Electrical Data Power Supply(V/Hz) Power(W) Electrical Current(A) Capacity(L/Cu.Ft) HYC-68 N HYC-118A HYC-260 HYC-360 N N N N HYC-290 N N Forced air cooling HYC-610 HYC-940 HYC-1378 Upright, single door Upright, double door Upright, double door ST N N Forced air cooling Forced air cooling Forced air cooling HYC-390 Upright, single door Upright, single door Upright, single door N Forced air cooling Forced air cooling Forced air cooling Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto Auto CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free CFC-Free 30 30 30 30 55 55 43 43 43 42 2-8 2-8 2-8 2-8 2-8 2-8 2-8 2-8 2-8 2-8 2-8 Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor LED LED LED LED LED LED LED LED LED 220~240/50 220~240/50 115/60 220~240/50 220~240/50 220~240/50 208~230/60 115/60 Microprocessor Microprocessor LED 220~240/50 208~230/60 220~240/50/60 LED 43 84 68 135 75 165 340 340 340 430 430 340 380 490 560 560 0.65 0.65 1.1 1.03 1.11 1.16 2.6 2.6 3.6 3.5 3.5 2.2 2.4 3.5 3.5 7.5 900 850 5.5 900 800 800 950 4.2 4.2 11 68/2.4 118/4.2 118/4.2 260/9.2 360/12.7 290/10.2 390/12.7 610/21.6 890/31.4 1378/48.7 38/40(kg) 83.8/88.2(lbs) 415*385*505 16.3*15.2*19.9 495*580*660 19.5*22.8*26.0 522*620*690 20.6*24.4*27.2 41/46(kg) 90.4/101.4(lbs) 515*415*630 20.3*16.3*24.8 597*645*835 23.5*25.4*32.9 675*680*930 26.6*26.8*36.6 41/46(kg) 90.4/101.4(lbs) 512*415*638 20.2*16.3*25.1 597*645*835 23.5*25.4*32.9 675*680*930 26.6*26.8*36.6 88/100(kg) 194.0/220.5(lbs) 550*460*1065 21.7*18.1*41.9 620*655*1720 24.4*25.8*67.7 700*715*1810 27.6*28.1*71.3 99/114(kg) 218.3/251.3(lbs) 550*460*1340 21.7*18.1*52.8 620*655*1995 24.4*25.8*77.0 700*715*2080 27.6*28.1*81.9 105/128(kg) 231.5/282.2(lbs) 530*555*1080 20.9*21.9*42.5 665*710*1665 26.2*28.0*65.6 125/150(kg) 275.6/330.7(lbs) 530*555*1380 20.9*21.9*54.3 665*710*1965 26.2*28.0*77.4 204/227(kg) 449.7/500.4(lbs) 680*640*1400 26.8*25.2*55.1 780*840*1945 30.7*33.1*76.6 865*945*2105 34.1*37.2*82.9 227/279(kg) 500.4/615.1(lbs) 1030*590*1425 40.6*23.2*56.1 1130*755*1980 44.5*29.7*78.0 1250*850*2130 49.2*33.5*83.9 310/360(kg) 683.4/793.7(lbs) 1320*700*1500 52.0*27.6*59.1 1440*910*1980 56.7*35.8*78.0 1600*1010*2100 63.0*39.8*82.7 108/228/228 48/102/102 48/102/102 24/48/48 24/48/48 16/32/32 16/32/32 12/26/26 8/18/18 6/12/12 735*800*1800 735*800*2100 28.9*31.5*70.9 28.9*31.5*82.7 Y Y Y Y Y Y Y Y Y Y Y N/A N/A N/A N/A N/A N/A Y Y Y Y Y Power Failure N/A N/A N/A N/A Y Y Y Y Y Y Y Sensor Error Y Y Y Y Y Y Y Y Y Y Y Low Battery N/A N/A N/A N/A Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N/A N/A N/A N/A Y Y Y Y Y Y Y Y Y N/A Y Y Y Y Y N/A N/A Y Y Y Y Y Y Y Y N/A Y N/A Door Ajar Caster Foot Test Hole N/A 2/- 2/1 3/1 3/1 4/- 5/- 4/1 6/1 6/- 12/- 12/- USB Interface N/A N/A N/A N/A N/A N/A Y Y N/A N/A N/A Tmt. Recorder N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Certificate CE CE,UL CE,UL CE CE CE / / / CE CE Accessories Shelves/Basket 48 220~240/50/60 220~240/50 208~230/60 115/60 220~240/50208~230/60115/60220~240/50208~230/60115/60 84 68/2.4 43 Remote Alarm High/Low Temperature Others HYC-118 Forced air cooling Forced air cooling Forced air cooling Forced air cooling Net/Gross 38/40(kg) 83.8/88.2(lbs) Weight(approx) Interior Dimensions (mm) 415*385*505 (in) 16.3*15.2*19.9 Dimensions (W*D*H) Exterior Dimensions (mm) 495*580*660 (W*D*H) (in) 19.5*22.8*26.0 PackingDimensions (mm) 522*620*690 (W*D*H) (in) 20.6*24.4*27.2 Container load 108/228/228 (20'/40'/40'H) Functions HYC-68A Upright, foam door Upright, glass door Upright, foam door Upright, glass door Upright, single door Pharmacy Refrigerator Model Cabinet Type Blood Bank Refrigerator Biomedical Blood Bank Refrigerator Haier blood bank refrigertators are specially designed to store whole blood and blood derivatives. These refrigerators can also be used to store pharmacy and biological materials in hospitals and laboratories. The Haier BBR series provides two styles to storage systems: basket-type and rawer type.They are built in compliance with the requirements of : • • • • AABB (American Association of Blood Banks) DIN 58371 (Germany, “Blutkonserven-Kühlgeräte”/Blood Refrigerators) BIS 4376-1: 1991 (UK, “Electrically operated blood storage refrigerators. Specifications for closed reach-in types”) • In 2011, Haier won MOH tender blood bank refrigerator and -86°C ULT freezer in Russia market • In 2011, Haier won the tender "Third National HIV/AIDS Control Project (NACP III)” and successfully supplied and installed Blood Bank Refrigerators, -86°C ULT Freezers and -40°C Deep Freezers. LED light Double-layer glass, electrical heating, free from condensation. Permanently lubricated evaporator fan motor Reliability Test Hole • Microprocessor controlled forced-air cooling with electrical heat compensation system • Digital temperature display for upper and lower sections in chamber with 0.1 °C resolution Key Features • Consistent cabinet temperature 4±1°C • High-tech integrated sensors to display and control temperature • Standard temperature recorder (Optional for HXC-158) • Auto-defrost to remove moisture on cooling surface • Large digital display for ease of observation Safety • Dual displays of operational parameter temperature recorder display) Blood basket or drawer is optional • Built-in backup battery to display temperature and to Hermetically sealed compressor Ergonomic Design Lockable caster HXC-358B • Safety lock to prevent unauthorized access • Storage space designed for easy sorting of a variety of blood products • Caster design and interior light • Optional baskets or stainless steel drawers Blood Bank Refrigerator Temperature recorder operate audible and visual alarm systems for up to 48 hours without ac power • Three types of alarm alerts: Buzzer, Flashing light, and remote alarm • Five alarm conditions: High /low temperature, power failure, sensor error, door ajar, low voltage in backup battery Biomedical Lights when display indicates upper sensor temperature Lights when display indicates lower sensor temperature Lighted to indicate power supply connection, flashes to indicate power supply failure Both lighted displays the average temperature of upper and lower sensors The standard drawers can be optionally fitted with adjustable dividers. This guarantees neatly and clearly arranged storage of your goods. HXC-608 Pull down test at 32°C ambient Flashes to indicate alarming status To cancel buzzing 36 32 28 To adjust the displayed temperature To test alarm function To calibrate upper sensor, lower sensor and control sensor To select sensor to calibrate Temperature(°C) 24 20 16 12 8 4 To cancel calibration 0 10 20 30 40 50 60 70 80 90 100110 120 130 140 150 160 Time (min) HXC-608 Pull-up test at 32°C ambient High Temperature Temperature reaches the warm alarm limit Low Temperature Temperature reaches the low alarm limit Power Failure Equipment loses power Probe Failure 1.Main cabinet temperature control sensor fails 2.Condenser sensor fails 3.Ambient sensor fails 4.Heat exchanger sensor fails Low Battery Battery capacity runs low or battery switch is not turned on Door Ajar Door open period exceeds 600s 36 32 28 24 20 16 12 8 4 0 10 20 30 40 50 60 70 80 90 100110 120 130 140 150 160 Time (min) Blood Bank Refrigerator Alarm Triggering Condition Temperature(°C) Alarm Blood Bank Refrigerator Biomedical Specification Model HXC-158 HXC-358 Technical Data Performance Electrical Data HXC-158B HXC-608B HXC-358B HXC-1308B Drawer-Type ST ST ST N ST ST ST N Cooling Type Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Deforst Mode Auto Auto Auto Auto Auto Auto Auto CFC-Free 42 4+1 _ CFC-Free 43 4+1 _ CFC-Free 43 4+1 _ CFC-Free 43 4+1.5 _ CFC-Free 42 4+1 _ CFC-Free 43 4+1 _ Auto CFC-Free 43 4+1 _ Refrigerant Noise(dB) Temperature Range( °C) CFC-Free 43 4+1.5 _ 10-38 10-38 10-38 10-32 10-38 10-38 10-38 10-32 Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor LED LED LED LED LED LED LED LED 220~240/50/60 220~240/50 /60 220~240/50 /60 220~240/50 220~240/50/60 220~240/50/60 220~240/50/60 220~240/50 Power(W) 350 460 490 850 350 460 490 850 Electrical Current(A) 2.6 3 3.5 4.2 2.6 3 3.5 4.2 158/5.6 358/12.7 608/21.5 1308/46.2 158/5.6 358/12.7 608/21.5 1308/46.2 84 200 300 576 84 200 360 720 107/120(kg) 235.9/264.6(lbs) 158/174(kg) 348.3/383.6(lbs) 204/227(kg) 449.7/500.4(lbs) 310/360(kg) 683.4/793.7(lbs) 107/120(kg) 235.9/264.6(lbs) 158/174(kg) 348.3/383.6(lbs) 204/227(kg) 449.7/500.4(lbs) 335/385(kg) 738.5/848.8(lbs) Ambient Temperature (°C) Controller Power Supply(V/Hz) Capacity(L/Cu.Ft) Blood Storage Capacity (450ml blood bags) Net/Gross Weight(approx) Dimensions HXC-1308 Climate Class Display Control HXC-608 Basket-Type Type Interior Dimensions (W*D*H) Exterior Dimensions (W*D*H) 460*370*950(mm) 620*490*1160(mm) 24.4*19.3*45.7(in) 18.1*14.6*37.4(in) 560*570*1530(mm) 720*690*1730(mm) 22.0*22.4*60.2(in) 28.3*27.2*68.1(in) 680*640*1400(mm) 26.8*25.2*55.1(in) 780*840*1945(mm) 30.7*33.1*76.6(in) 1320*700*1500(mm) 52.0*27.6*59.1(in) 1440*925*1980(mm) 56.7*36.4*78.0(in) 460*370*950(mm) 18.1*14.6*37.4(in) 560*570*1530(mm) 22.0*22.4*60.2(in) 620*490*1160(mm) 24.4*19.3*45.7(in) 720*690*1730(mm) 28.3*27.2*68.1(in) 680*640*1400(mm) 26.8*25.2*55.1(in) 780*840*1945(mm) 30.7*33.1*76.6(in) 1320*700*1500(mm) 52.0*27.6*59.1(in) 1440*925*1980(mm) 56.7*36.4*78.0(in) Packing Dimensions (W*D*H) 645*675*1660(mm) 805*795*1870(mm) 31.7*31.3*73.6(in) 25.4*26.6*65.4(in) 865*945*2105(mm) 1600*1010*2100(mm) 34.1*37.2*82.9(in) 63.0*39.8*82.7(in) 645*675*1660(mm) 25.4*26.6*65.4(in) 805*795*1870(mm) 31.7*31.3*73.6(in) 865*945*2105(mm) 34.1*37.2*82.9(in) 1600*1010*2100(mm) 63.0*39.8*82.7(in) 24/54/54 14/30/30 12/26/26 6/12/12 Container load (20'/40'/40'H) 27/54/54 14/30/30 12/26/26 6/12/12 Y Y Y Y Sensor Error Y Y Y Y Y Y Y Y Low Battery Y Y Y Y Y Y Y Y Door Ajar Y Y Y Y Y Y Y Y Remote Alarm Y Y Y Y Y Y Y Y Caster Y Y Y Y Y Y Y Y Foot Y Y Y Y Y Y Y Y Test Hole Y Y Y Y Y Y Y Y 4/16 5/20 6/24 12/48 _ _ _ _ -/2 -/3 -/3 -/6 4(Drawers) 5(Drawers) 6(Drawers) 12(Drawers) Y High/Low Temperature Functions Accessories Shelves/Baskets Drawers/Inner doors USB Interface Temperature Recorder Others Certificate N/A N/A N/A Y N/A N/A N/A Optional Y Y Y Y Y Y Y CE CE CE CE CE CE CE CE Blood Bank Refrigerator Power Failure Vaccine Storage Solution 61 62 Vaccine & Icepack Freezer Biomedical The refrigerators are designed to store vaccine, pharmaceuticals and so on. Applicationscould be found in epidemic prevention, clinics,hospitals, research institutes etc. WHO/UNICEF qualified supplier • From 2004 until now, Haier awarded the tender from India MOHFW, WHO, UNICEF, Africa market to supply about 50,000 units icepack freezers and ice-lined refrigerators. • 2009, World Health Organization (WHO) qualified Haier Medical as the supplier of ice-lined refrigerators and -25°C vaccine and ice pack freezer lines. The pre-qualified models include HBC-70, HBC-200, HBD-286, HBD-116. • 2011, Haier got the LTA of Ice-Lined Refrigerator and Vaccine Freezer. Haier is the long term supplier of UNICEF. Model HBD-116 HBD-286 Chest Chest Cabinet Type <43°C <43°C Cooling Type Direct cooling Direct cooling Defrost Mode Manual Manual Refrigerant CFC-Free CFC-Free Noise(dB) 43 44 -15~-25 -15~-25 Mechanical Mechanical LCD LCD Ambient Temperature Technical Data HBD-116 HBD-286 Refrigeration System Ergonomic Design • Highly efficient hermetically sealed compressor • CFC-free high density foam insulation • Optimized refrigeration system design • • • • • Temperature Control Performance Safety lock for unauthorized access Corrosion-proof interior and ease of cleaning Shelving designs for various sizes of storage baskets Drainage system for ease of cabinet cleaning LCD temperature display Control Controller Display 220~240/50 208~230/60 220~240/50 Power(W) 138 166 185 Electrical Current(A) 1.05 1.65 1.3 Power Consumption: stable running(KWh/24h) 3.01 3.53 3.48 Power Consumption: cool down test(KWh/24h) 3.25 3.47 3.71 Power Supply(V/Hz) Electrical Data • Digital display • Adjustable temperature range of -15°C to -25 °C Temperature Range(°C) more than 3hrs(up to -5°C) more than 50hrs(up to 10°C) more than 5hrs(up to -5°C) more than 60hrs(up to 10°C) Vaccine Storage Capacity(L/Cu.Ft) 97/3.4 258/9.1 Gross Volume(L/Cu.Ft) 121/4.3 286/10.1 57/61(kg) 125.7/134.5(lbs) 79/85(kg) 174.2/187.4(lbs) 497*457*655(mm) 19.6*18.0*25.8(in) 1067*457*655(mm) 42.0*18.0*25.8(in) 670*630*818(mm) 26.4*24.8*32.2(in) 1240*630*818(mm) 48.8*24.8*32.2(in) Holdover Time at 32°C HBD-286 Pull down test at 43 °C ambient HBD-286 Pull-up test at 43 °C ambient 50 50 43 40 30 30 20 20 Temperature Temperature 40 10 0 -10 -20 -50 -50 20 25 30 35 40 45 50 55 60 Time (H) Packing Dimensions(W*D*H) -20 -40 15 Container load (20'/40'/40'H) Accessories 0 05 10 15 20 25 30 35 40 45 Time (H) 63 Interior Dimensions(W*D*H) Exterior Dimensions(W*D*H) -10 -30 10 Dimensions 0 -40 05 Net/Gross Weight(approx) 10 -30 0 43 50 55 60 Others Wooden 820*820*1045(mm) 32.3*32.3*41.1(in) Wooden 1385*820*1045(mm) 54.5*32.3*41.1(in) Paper 755*760*880(mm) 29.7*29.9*34.6(in) Paper 1325*760*880(mm) 52.2*29.9*34.6(in) 28/56/56(Wooden) 42/90/135(Paper) 16/32/32(Wooden) 24/54/81(Paper) Foot Y Baskets Certificate Y 2 3 CE,WHO/PQS CE,WHO/PQS 64 Vaccine & Icepack Freezer • 2014,Haier broken the European & USA monopoly of the vaccine refrigerator in Africa market -1000 units was awarded by the PFSA Ethiopia. Biomedical Ice-Lined Refrigerator Refrigeration System • Optimized refrigeration system design • Built-in ice packs maintain 2°C to 8°C for 25 hours at43°C ambient • CFC-free high density foam insulation • Complied with WHO/UNICEF standards Temperature Control • Digital temperature display • Adjustable control range of 2°C to 8°C Ergonomic Design Ice-Lined Refrigerator • Door lock for storage safety • Stainless steel interior for ease of cleaning and corrosion proof 65 66 Biomedical Solar Direct Driven Vaccine Refrigerator WHO/UNICEF qualified supplier • Haier successfully won the UNICEF tender of 100 units SDD Refrigerator HTC-60 for aiding North Korea project and dispatched engineers to DPR Korea for the taining. For Solar-powered Vaccine Refrigerator, electricity and fuel are unneeded. It provides with convenienceto store vaccine for the areas without power or power unstable regions, especially frequent blackout. This kind of refrigerator can also be used for vaccine storage in developing countries. Haier has repeatedly taken part in the project of children health protecting in WHO,UNICE, Africa and other developing regions, providing the solutions of vaccine storage security. • 2014 Haier has been awarded 1,000 units SDD Vaccine Refrigerator of HTC-60 PO from MOH of Ethiopia. Storage security • Forced air cooling system designed to provide stable and uniform chamber temperature • LCD temperature display to read the visual temperature • High and low temperature and power outage alarm system, multiple built-in protection system • Corrosion-resistant stainless steel liner • Lock design, safe to storage the vaccine • Keeping inside temperature at 2-10°C, in the condition that ambient temperature is 32 °C power outage for 119 hours , safe for vaccine storage Temperature control Ergonomic design • Microcomputer control, guarantee the accurate temperature • Temperature measurement function, the temperature inside chamber is accordance with the display temperature • Solar-driven, green and environment friendly compared with battery-powered ones • External battery can be connected to the unit under special or emergency situation flexibly • Temperature controller is easy to view, auxiliary battery for display without sunshine • Low noise EXTERNAL DIGITAL DISPLAY SDD Vaccine Refrigerator The current temperature is displayed through the solar driven digital display. There is no need for daily adjustment, as the entire system has been calibrated before delivery from the factory and it is selfregulating. 67 68 Biomedical Solar Direct Drive Refrigerator And Freezer LED temperature display Technical Data Performance Control Electrical Data Dimensions Lock design, safe to storage the vaccine Model HTCD-160 Cabinet Type Uprignt Cooling Type Direct cooling Refrigerant CFC-Free Defrost Mode Manual Temperature Range 2~8°C Controller Microprocessor Display LED Power 24V Holdover Time at 43°C >72hrs Autonomy Time >72hrs Solar Radiation Reference Period 3.5kwh/m2/day Voltage of Solar Panel 24V Power of Solar Panel 500W Gross Volume(L/Cu.Ft) 120/4.2 Exterior Dimensions(W*D*H) 865*830*1830 (mm) 34.1*32.7*72.0(in) Funtions Accessories Storage Security Ergonomic Design • • • • • Solar-driven, without any battery, green and environment friendly. • Products continue to display the in the, when the power is easy to see. • Cabinet temperature can be continued display when power off. • Double cooling system, any one room can be stopped according to the need. • Low noise. LED temperature display Functions: High and low temperature, sensor error Lock design, safe to storage the vaccine Keeping inside temperature at 2~10℃, in the condition that ambient temperature is 43℃ power outage for more than 72 hours, safe for vaccine storage. Temperature Control High/Low Temperature Y Sensor Error Y Shelves 2(Refrierator Room) Walk-In Cold/Freezer Room HTCD-160 • Microprocessor control, guarantee the accurate temperature. 69 70 Biomedical Walk-In Cold/Freezer Room Integral Cold Store Unit • The cold room is suitable to freeze or refrigerate relevant articles for medical service, scientific research,agricultural, biological and chemical industries, etc. Its interior temperature can be controlled respectively within the range of 0~10°C or 0~-25°C Haier walk-in cold room is for storage of vaccines, and the complete unit is also designed for installation in a housed area such as a warehouse in order to meet designed temperature standards. Haier’s WICs & WIFs have passed WHO / PQS and is long term supplier of UNICEF. The units have been installed in India, Guinea, South Sudan, Pakistan, Burundi, Uzbekistan, etc. Technical Characteristics of the Cold Room • The cold room for vaccines and medicines is controlled and adjustable within the range of 0~10°C or -15~-25°C with resolution of 0.1°C • Insulation material CFC-free polyurethane foamed-inpiece, density 42kg/cbm • Insulation thickness 100 mm, K-value 0.22 W/m2K or better • Internal and external surfaces of hot-dipped galvanized steel sheet,white polyester coating and floor clad with non-slip material • Rooms equipped with tungsten lighting and with an external switch with pilot lamp • Rooms equipped with shelving system on three walls, material stove enameled steel, galvanized steel,stainless steel, aluminum or plastic slatted adjustable shelving units to carry vaccine in packages, 5 levels, 450-600 mm deep, adjustable • Dual refrigeration system is equipped. Forced air-cooled condenser refrigeration units • Door equipped with heavy duty hinges and lock with internal safety release. Automatic defrosting • CFC-free refrigerant • System to be offered with manual change over switch as standard • Temperature recorder and audible alarm system Technical Characteristics of the Refrigerating Unit Temperature Recorder • • • • • 71 Upper and lower limits +50°C to -30°C Accuracy ±1°C Resolution ±0.5°C Minimum acceptable recording period between chart changes is 7 days USB interface is equipped 72 Walk-In Cold/Freezer Room • The LYJ series of machine, called mono block, that integrates evaporator, condenser, compressor, electrical control units into one compact body, can be widely used for cold storage rooms of temperature of -5°C~5°C or -15°C~-20°C, in hotels, restaurants, medicines, agricultural, chemicals industries all other place where cold storage is needed. This series products feature below: • With very compact structure • With TECUMSEH hermetic compressors, high efficient in-grooved copper tube and aluminum fin heat exchangers and world famous brand refrigeration parts for all products • The electronic control boards are with functions of automatic temperature set, control, and electric heater defrosting. • • • Protection devices for over loading, over heating, lack of phase, high & low pressure etc • Safe, easy, and low cost for installation and operation Laboratory Equipment 73 74 Biomedical Features Biological safety cabinet is designed to protect operator, laboratory environment and samples from being exposed to the infective aerosol produced when the sample is bacteria strains, diagnostic material, and other infective subjects. It provides the operators with a more comfortable and safer working condition. It is widely used in medical health, disease prevention, food safety, biological pharmacy and environment monitoring. And it has been the important basis of sample safety and environment security. Patent Intelligent Constant Air Velocity The professional hot-bulb air velocity transducer performs real-time monitoring on the air velocity of the working area, compares it with the standard air velocity, and keeps the safety cabinet under constant air velocity through adjustment of the fan speed by microcomputer system. LNS Green Energy-saving Mode When the human body detecting module detects under the intelligent mode that the person is outside the operating area for over 15 minutes, the microcomputer program will automatically switch the safety cabinet to LNS green energy conservation mode (Low noise and energy conservation), so as to realize noise reduction and energy conservation and to improve the service life of the filter. Ultra Low Penetration Air Filter System Professional Air-flow Distribution Module Through professional air flow distribution design, the air flow of the worktable is more uniform, with the noise <62dBA American AAF ULPA filter Ultra Low Penetration Air Filter System Intelligent constant air velocity patent technology American AAF (ULPA) filter are tested to a typical efficiency of > 99.999% for 0.12 micron particles. ULPA Filter provides vertical laminar flow to the worktable, so as to protect samples from pollution. The professional hot-bulb air velocity transducer performs real-time monitoring on the air velocity of the working area, compares it with the standard air velocity, and keeps the safety cabinet under constant air velocity through adjustment of the fan speed by microcomputer system Patent Technology of Air Flow Disruption Adopt the patent technology of air flow disruption on the upper edge and both sides of the front window (Patent No. ZL200520125549.X) to eliminate the safety protection blindness. Adopt the patent technology of side air flow disruption design to eliminate the exposure of microorganism. 304 stainless steel operation platform and internal wall Stainless steel operation platform without screws, no accumulation of contaminant Dismountable air in-flow plate, easy to clean and disinfect Concaved operation platform, waste liquid easily collected HR1500-IIA2 Unique Drop-down Front Glass Window Remove the hand-placing frame by hand, and pull down the front glass window to clean the upper part of the glass and to avoid dead corners. Digital microprocessor control system Dismountable Platform-type Hand-placing Frame Platform-type hand-placing frame is comfortable to use and helps to relieve fatigue Professional air flow distributiondesign Through professional air flow distribution design, the air flow of the worktable is more uniform, with the noise 〈62dBA 75 V-shaped air inlet design Swivel caster, Internal thread support leg Biological Safety Cabinet LCD display Real-time display of key parameters: downflow velocity, inflowvelocity, airflow volume, static pressure, negative pressure,accumulative running time of fan and UV lamp, left lifetime of filter Sound & light alarming function UV sterilization reservation setting function 76 Biomedical American AAF ULPA filter are tested to a typical efficiency of >99.999% for 0.12 micron particles Reverse centrifugal fan allows double side air inflow, decreasing noise and saving energy Reverse centrifugal fan allows double side air inflow, decreasing noise and saving energy Digital microprocessor control system for easy operation Intelligent alarming system Multiple interlocking functions eliminate potential safety problems caused by misoperation. Removable stainless steel work surface makes cleaning easier Ergonomic angled design to improve comfort 304 stainless steel operation platform and internal wall • Stainless steel operation platform without screws, no accumulation of contaminant • Dismountable air in-flow plate, easy to clean and disinfect • Internal wall is constructed by a single plate, and the12mm arc angle conner leaves no cleaning blind area • The volume of liquid tank is over 4L, equipped with outlet valve for convenient cleaning and maintaining • Concaved operation platform, waste liquid easily collected • Adjustable supporter (0-75mm) without exposed screw thread, preventing the germs from multiplying Ultra Low Penetration Air Filtration System • American AAF ULPA filter • Tested to a typical efficiency of 99.9995% for 0.12 micron particles • Provides FED STD 209E class 1 (or ISO14644.1 class 3) clean air to work surface in a stable vertical laminar flow to protect samples • The exhaust ULPA filter traps biohazard particles acquired from the work surface before air is exhausted to the room, offering personnel and environmental protection High Efficiency Blower System • The blower system is designed for high performance operation, maximum energy efficiency and minimal maintenance • Self cooling system reduces energy consumption while enhancing reliability Reverse centrifugal fan 77 Double-side air inflow design decreases running noise Air velocity auto-compensation function guarantees stable wind speed 78 Provide uniform airflow by adjusting working voltage of fan. Biological Safety Cabinet Adjustable foot Biomedical Specification Model Working Voltage& Frequency HR900-IIA2 HR1200-IIA2 220V/50Hz 220V/50Hz HR1500-IIA2 HR30-IIA2 HR40-IIA2 HR60-IIA2 HR40-IIB2 220V/50Hz 220V/50Hz 220V/50/60Hz 220V/50Hz 220V/50Hz 1300 1300 1300 1300 350 350 350 Power(VA) 1400 1500 1700 Power of Blower(W) 280 394 650 Airflow Circulation Main Filter Typical Effiency Exhaust Filter Typical Effiency Downflow Velocity(m/s) Inflow Velocity(m/s) 70% downflow, 30% exhaust 70% downflow, 30% exhaust 70% downflow, 30% exhaust 700 100% exhaust 70% downflow,30% exhaust 70% downflow,30% exhaust 70% downflow,30% exhaust ULPA,[email protected] ULPA,[email protected] ULPA,[email protected] ULPA,99.9995%@0.12μm ULPA,99.9995%@0.12μm HEPA,99.995%@0.3μm ULPA,99.9995%@0.12μm HEPA,99.99%@0.3μm ULPA,99.9995%@0.12μm ULPA,99.9995%@0.12μm ULPA,[email protected] ULPA,[email protected] ULPA,[email protected] ULPA,99.9995%@0.12μm 0.31 0.34 0.31 0.30 0.28 0.32 0.32 0.55 0.58 0.55 0.58 0.62 0.55 0.55 900 900 900 ≥1100 ≥1100 ≥1100 ≥1100 Net/Gross Weight 290/315(kg) 639.3/694.5(lbs) 320/347(kg) 705.4/765(lbs) 333/368(kg) 734.1/811.3(lbs) 220/248(kg) 485.0/546.7(lbs) 258/293(kg) 568.8/646.0(lbs) 328/390(kg) 723.1/859.8(lbs) 280/315(kg) 617.3/694.5(lbs) Internal Dimensions(W*D*H) 920*620*650(mm) 36.2*24.4*25.6(in) 1220*620*650(mm) 48.1*24.4*25.6(in) 1520*620*650(mm) 59.9*24.4*25.6(in) 900*610*680(mm) 35.4*24.0*26.8(in) 1167*610*680(mm) 45.9*24.0*26.8(in) 1735*610*680(mm) 68.3*24.0*26.8(in) 1167*610*680(mm) 46.0*24.0*26.8(in) External Dimensions(W*D*H) 1080*845*2160(mm) 42.5*33.3*85.0(in) 1380*845*2160(mm) 54.3*33.3*85.0(in) 1680*845*2160(mm) 66.2*33.3*85.0(in) 1100*780*2200(mm) 43.3*24.0*26.8(in) 1360*780*2200(mm) 53.5*30.7*86.6(in) 1960*780*2200(mm) 71.2*30.7*86.6(in) 1360*780*2400(mm) 53.5*30.7*94.5(in) Packing Dimensions(W*D*H) 1145*920*1690(mm) 69.1*36.2*66.5(in) 1470*920*1690(mm) 57.9*36.2*66.5(in) 1755*920*1690(mm) 69.1*36.2*66.5(in) 1170*930*1700(mm) 46.1*36.6*67.0(in) 1430*930*1700(mm) 56.3*36.6*67.0(in) 2000*930*1700(mm) 78.7*36.6*67.0(in) 1430*930*1900(mm) 56.3*36.6*74.8(in) 75mm adjustbale height 75mm adjustbale height 75mm adjustbale height 75mm adjustable height 75mm adjustable height 75mm adjustable height 75mm adjustable height 7/30/15 7/30/15 3/30/15 10/20/20 8/16/16 4/10/10 8/16/16 Sound and Flash Sound and Flash Sound and Flash EN12469,SFDA,CE SFDA SFDA Supporter Container load (20'/40'/40'H) Alarm Certificate Sound and Flash Sound and Flash Sound and Flash Sound and Flash CE,EN12469,SFDA CE,,EN12469,SFDA CE,EN12469,SFDA SFDA Biological Safety Cabinet Fluorescent Lamp Intensity(Lux) 79 80 Biomedical Clean Bench High-efficiency Filter ULPA The world-famous AAF damp and fire resistant fiberglass high-efficiency air filter (HEAP) 99.99%@0.3μm, enjoys the cleaning class up to Class V, ISO14644.1 which is superior to the cleaning requirement of class 100, safer and cleaner. 304 Stainless Operation Table Featuring many patented technologies and authoritative testing certification for reliability Microcomputer intelligent control panel with durable touch buttons Multiple safety protection functions including UV delay start Interlocking function to put an end to incorrect operation Various personalized design to ensure comfortable operation Perfect memory function to avoid repeat setting Combined under-frame structure with universal truckle design The excellent 304 stainless operation table without fixing screws can avoid the accumulation of dirt. Ergonomic Design • Adopting recess lighting to eliminate the radiation of the fluorescent lamps on the eyes and thus preventing the eyes from being tired. • Equalizer bar design: In the working area, the stainless equalizer bar with hooks is provided for facilitating the movement of articles. Patented Technology • UV sterilization startup delay (keep away the injury by UV light) patent technology (ZL201220087011.4), After the UV lamp switch is pressed down, the audible and visual alarm will be activated to remind the operator to leave in time. After 10s, the UV light is on. Therefore, the operator can be protected from the injury by UV light. • Preset function: It can preset the UV sterilization startup delay to provide users with more rest and to improve working efficiency, possessing the patent technology (ZL201220087011.4). Interlocking Function High-efficiency Filter ULPA With the interlocking between illuminating lamp and UV lamp, the UV lamp can become on only when the illuminating lamp is off; When the UV lamp is on, it can be off if pressing the daylight lamp. The risk of incorrect operation can be avoided.s Memory Function Shell : Cold rolled electrostatic painting , anti -corrosion ability The UV lamp startup delay time, sterilization duration, preset start time, fan position can be set and saved by user on request for the convenience of startup. One-key Operation UV germicidal delayed start , from away UV damage • After the UV lamp switch is pressed, the time function can be activated automatically. The default sterilization time is 30min, which can be adjusted by user within 0~99min on request. • Sterilization preset, when pressing the UV lamp, the preset lamp will become on to remind user that the sterilization preset function has been activated and that the sterilization preset can be conducted. Pre-cleaning Function The only pre-cleaning function can further improve the protection on sample. Model Pre-cleaning Function: patent technology (ZL201220087011.4). 304 Stainless Operation Table UV lamps , fans, lighting linkage system to enhance user 81 Universal Caster to move more conveniently Flow Type Voltage/Frequency Power Vibration Amplitude Exhaust Filter Typical Efficiency Average Velocity Fluorescent Lamp Intensity Net/Gross Weight Noise Internal Dimension(W*D*H) External Dimension(W*D*H) Packing Dimension(W*D*H) Supporter Cleanliness Classification Container Load(20'/40'/40'H) Alarm Certificate HCB-900V(S) Vertical 220V/50Hz 1200W ≤2um HEPA,[email protected] 0.2~0.5m/s ≥600 Lux 115/130(kg) 254/287(lbs) ≤60dBA 1000*550*520 (mm) 39.4*21.7*20.5(in) 1070*630*1730 (mm) 42.2*24.8*66.1(in) 1205*745*1280(mm) 47.5*29.4*50.4(in) 75mm adjustbale height ISO14644.1 Class 5 7/30/15 Sound and Flash SFDA 82 HCB-1300V(S) Vertical 220V/50Hz 1200W ≤2um HEPA,[email protected] 0.2~0.5m/s ≥600 Lux 145/160(kg) 320/353(lbs) ≤60dBA 1300*550*520 (mm) 51.2*21.7*20.5(in) 1370*630*1730 (mm) 54*24.8*66.1(in) 1505*745*1280(mm) 59.3*29.4*50.4(in) 75mm adjustbale height ISO14644.1 Class 5 3/30/15 Sound and Flash SFDA Biological Safety Cabinet UV Lamp One-key Preset 83 84 Biomedical Liquid Nitrogen Container For Storage These products are specially designed for customers who will store biological samples or liquid nitrogen for and extended period time under static environment. YDS Coding System Explanation Features YDS • Used advanced powder coating Means Container Caliber (mm), Caliber 50mm is omitted. Means Special Type. technique avoiding of the traditional. shortcoming of paintings' drop. • High-strength aluminum alloy structure. • Multi-layer thermal isolation design. • Protective jacket to prevent collision. • 5-years on vacuum warranty. • Optional accessories. Means Container Normal Capacity (L). Parameters Model unit YDS-2-30 YDS-3 YDS-6 YDS-10 L 2 3.15 6 10 10 10 13 Empty Weight KG 2.9 3.5 5 6.3 6.5 6.9 6.6 Neck Diameter MM 30 50 50 50 80 125 50 Outer Diameter MM 224 224 300 300 300 300 310 Capacity E.g.1: YDS-30 means liquid nitrogen biological container for storage of 30L nominal capacity with 50mm caliber. E.g.2: YDS-35B-80 means liquid nitrogen biological container for transportation of 35L nominal capacity with 80mm caliber. Cork Handle Evacuating Nozzle MM 378 429 476 536 540 546 610 Static Evaporation Loss L/D 0.07 0.12 0.12 0.12 0.21 0.43 0.12 109 D 28 26 52 86 48 24 Canister Outer Diameter MM 19 38 38 38 63 97 38 Canister Height MM 120 120 120 120 120 276 276 Numbers of Canisters EA 3 6(3) 6(3) 6(3) 6(3) 1(0) 6(3) Straw Holding Capacity (single level) 0.5ml EA 90 792 792 792 2040 - 792 0.25ml EA 204 1788 1788 1788 4554 - 1788 Straw Holding Capacity (double level) 0.5ml EA - - - - - 1508 1284 0.25m EA - - - - - 3324 2832 Model unit unit YDS-15 YDS-15-125 YDS-20 YDS-30 L 15 15 20 31.5 31.5 30 35 Empty Weight KG 8.2 10.2 11.7 12 12.4 14.3 14 Neck Diameter MM 50 125 50 50 80 125 50 Outer Diameter MM 394 394 394 461 461 461 461 Height MM 575 585 656 655 656 659 695 Static Evaporation Loss L/D 0.11 0.37 0.12 0.12 0.21 0.33 0.12 D 134 42 168 254 147 90 286 Canister Outer Diameter MM 38 97 38 38 63 97 38 Canister Height MM 120 276 120/276 120/276 120/276 120/276 120/276 Numbers of Canisters EA 6(3) 1(0) 6(3) 6(3) 6(3) 6(3) 6(3) Capacity Multi-layer Thermal Isolation Neck Tube Adsorbent Inner Vessel Side Support Static Hold Time Outer Shell Canister Bottom Support Storage Type Transportation Type 85 YDS-13 Height Static Hold Time Locking Cover YDS-10-80 YDS-10-125 YDS-30-80 YDS-30-125 YDS-35 Straw Holding Capacity (single level) 0.5ml EA 792 - 792 792 2244 5124 792 0.25ml EA 1788 - 1788 1788 5022 11952 1788 Straw Holding Capacity (double level) 0.5ml EA - 1508 1284 1284 3624 9048 1284 0.25m EA - 3324 2832 2832 8460 19944 2832 86 Liquid Nitrogen Container Means the abbreviation of Liquid Nitrogen biological Container. Liquid Nitrogen Container Biomedical For Transportation Parameters Unit YDS-35-80 YDS-35-125 YDS-47-127 L 35 35 47 95 115 140 Empty Weight KG 14.2 14.5 15.4 34.5 38.5 42.5 55 Neck Diameter MM 80 125 127 216 216 216 216 Outer Diameter MM 461 461 461 681 681 681 681 Height MM 698 700 754 726 796 910 1026 Static Evaporation Loss L/D 0.22 0.36 0.45 0.97 0.94 0.96 0.95 D 159 97 105 98 122 146 184 Capacity Static Hold Time YDS-95-216 YDS-115-216 YDS-140-216 YDS-175-216 175 Canister Outer Diameter MM 63 97 97 Canister Height MM 120/276 120/276 120/276 - - - - Numbers of Canisters EA 6(3) 6(3) 6(3) - - - - Straw Holding Capacity (single level) Straw Holding Capacity (double level) Model Capacity 0.5ml EA 2244 5124 5124 - - - 0.25ml EA 5024 11952 11952 - - - - 0.5ml EA 3624 9048 9048 - - - - 0.25m EA 8460 19944 19944 - - - - Unit YDS-30125-F YDS-35- YDS-35B125-F 125-F YDS-47127-F YDS-50B125-F YDS-95- YDS-115- YDS-140216-F 216-F 216-F L 30 35 35 47 50 95 115 140 KG 14.3 14.5 14.8 15.4 21 34.5 38.5 42.5 55 Neck Diameter MM 125 125 125 127 125 216 216 216 216 Outer Diameter MM 461 461 461 461 461 681 681 681 681 Height MM 659 700 700 754 753 726 796 910 1026 Static Evaporation Loss L/D 0.33 0.36 0.41 0.45 0.45 0.97 0.94 0.96 0.95 D 90 97 86 105 110 98 122 146 184 EA 7(6) 7(6) 7(6) 7(6) 7(6) 7(6) 7(6) 7(6) 7(6) MM 82×84 82×84 82×84 82×84 82×84 142×144 142×144 142×144 142×144 MM 76×76 76×76 76×76 76×76 76×76 134×134 134×134 134×134 134×134 EA 4 5 5 6 6 8 10 Squre Canister Numbers of Squre Canisters Dimensions of Squre Canisters Number of Racks Layers of Squre Canisters 1.2&2ml vial capacity EA 700 875 875 1050 1050 5 3500 6 4200 5600 Remark: 1. Static evaporator loss and static hold time are nominal. Actual loss may be affected by the nature of the contents, atmospheric conditions, container history and manufacturing tolerances. 2. Work time is arbitrary, reference-only value to estimate container performance under the actual operating conditions. Features • Used advanced powder coating technique avoiding of the traditional shortcoming of paintings’ drop. • High-strength aluminum alloy structure. • Multi-layer thermal isolation design. • Protective jacket to prevent collision. • 5-years on vacuum warranty • Optional accessories YDS-175216-F Empty Weight Static Hold Time These products are specially designed for sample transportation with special side or bottom reinforcements. 175 7000 Parameters Model Capacity unit YDS-20B YDS-30B YDS30B-80 YDS-35B YDS35B-80 YDS35B-125 YDS-50B YDS50B-80 YDS50B-125 50 L 20 31.5 31.5 35 35 35 50 50 Empty Weight KG 11.5 12.5 13 14.1 14.3 14.8 19.3 20.1 21 Neck Diameter MM 50 50 80 50 80 125 50 80 125 Outer Diameter MM 394 461 461 461 461 461 461 461 461 Height MM 656 656 656 695 698 700 770 766 753 Static Evaporation Loss L/D 0.20 0.19 0.28 0.20 0.29 0.41 0.23 0.34 0.45 D 101 159 106 179 119 86 213 147 110 Canister Outer Diameter MM 38 38 63 38 63 97 38 63 97 Canister Height MM 120/276 120/276 120/276 120/276 120/276 120/276 Numbers of Canisters EA 6(3) 6(3) 6(3) 6(3) 6(3) 6(3) 6(3) Straw Holding Capacity 0.5ml EA (single level) 0.25ml EA EA EA Static Hold Time Straw Holding Capacity 0.5ml (double level) 0.25m 120/276 120/276 120/276 6(3) 6(3) 792 792 2244 792 2244 5124 792 2244 5124 1788 1788 5022 1788 5022 11952 1788 5022 11952 1284 1284 3624 1284 3624 9048 1284 3624 9048 2832 2832 8460 2832 8460 19944 2832 8460 19944 Remark: 1. Static evaporator loss and static hold time are nominal. Actual loss may be affected by the nature of the contents, atmospheric conditions, container history and manufacturing tolerances. 2. Work time is arbitrary, reference-only value to estimate container performance under the actual operating conditions. 87 88 Liquid Nitrogen Container Model CO2 Incubator Biomedical Haier CO2 incubators are widely applied to the research and production of medicine, immunology, genetics, microbiology, agricultural science and pharmacology. The incubators are ideal equipment for experimental study of in-vitro incubation of cells, tissue, microbes, etc. Large Color Screen Display A:Microbe High-efficiency Filter Multiple Disinfection Methods Easy to Clean A high-efficiency microbe filter, which comes with a sterilization function, is installed at the CO2 gas inlet. Its filtration efficiency is 99.99 percent, capturing particulates with diameters equal and greater than 0.3 um. The filtration system eliminates bacteria and particulates in the CO2 gas to create a healthy environment for reliable experiments. Standard features include stainless steel inner liner designed with rounded corners for ease of cleaning and anti-bacteria. Space Saving Units are conveniently stackable to allow laboratory space fully utilized. B:Door Frame Heating System Protection Safety Haier CO2 incubator’s outer door radiates heating energy into the inner glass door to prevent condensation from occurring. The dry inner door eliminates the possibility of microbial contamination that exists in condensate water. Alarm systems feature an independent over-temperature alarm system, and a sound, illuminator system, and remote alert system that report temperature, humidity, door ajar, and malfunction conditions. The alarm systems safeguard experiments effectively. C: Automatic Control of Circulating Fan Speed The air flow inside the chamber can be automatically controlled based on the requirement of an experiment. This feature reduces the risk of drying out test samples. D: 90°C High-temperature Moist Heat Disinfection System Moist heat disinfection at high temperature of 90°C can kill microbes and fungal spores on the inner surface of the incubator. Specifications: Ultraviolet sterilization system is positioned on the rear wall inside the incubator. It is used for quickly and effectively disinfecting the inside of the incubator body to kill any floating bacteria circulating in the air and water vapor in humidifying tray. This method thereby prevents potential contamination to cell incubation. Input Power Screen Size Heating Type F: Fast Recovery of Test Environment The incubator system operates with a perfect interaction of the high-precision infrared CO2 temperature sensor and the microcomputer controller. The result is that the CO2 concentration and temperature can be recovered to the set state quickly even when the doors are opened and closed frequently. The system maintains an excellent stability and uniformity of CO2 concentration and temperature at high usage conditions. G: Microcomputer Controller A large-screen liquid crystal display is a standard feature for ease of operation and clear display. It is controlled by a microcomputer precisely, and it can display temperature, CO2 concentration, and relatively humidity. H: Built-in Water Tray Design The floor of the inner door is by design an integral built-in water tray for humidification process. Pure water can be introduced directly to the water tray for a greater area of evaporation. This feature eliminates a separate water tray design which can be a source of contamination. I: Graphic Inquiry In the incubation process, all key operational parameters such as temperature, humidity, CO2 concentration and door usage are shown in a graphic form. Users can quickly use the information directly to analyze the incubation process. J: Door Action Actuated Control When the door is opened, operation of circulating fan, CO2 injection and heating system automatically stops temporally to reduce CO2 gas consumption, and temperature overshoot. When the door is closed, the system resumes operation automatically. 89 Control Range Operating Ambient Temperature Temperature Stability CO2 Control Range CO2 Control Accuracy CO2 Recovery Time Temperature Recovery Relative Humidity PYXE-80IR PYXE-150IR PYXE-240IR 500W 700W 1000W 5" LCD screen 5" LCD screen 5" LCD screen Air jacked heating system with microcomputer control Air jacked heating system with microcomputer control Ambient Temperature +5~50°C Ambient Temperature +5~50°C +5~30°C +5~30°C Air jacked heating system with microcomputer control Ambient Temperature +5~50°C +5~30°C ±0.3°C ±0.3°C ±0.3°C 0~20%V/V 0~20%V/V 0~20%V/V ±0.1% (infrared sensor) ±0.1% (infrared sensor) ±0.1% (infrared sensor) After the door is opened for 1 minute, CO2 concentration recovery time is less than 6 minutes. After the door is opened for 1 minute, CO2 concentration recovery time is less than or 6 minutes. After the door is opened for 1 minute, CO2 concentration recovery time is less than or 6 minutes. After the door is opened for 1 minute, temperature recovery time is less than or equal to 15 min at constant temperature of 37°C. Relative humidity can reach 95% through natural evaporation of water. Relative humidity level can be displayed. After the door is opened for 1 minute, temperature recovery time is less than or equal to 15 min at constant temperature of 37°C. Relative humidity can reach 95% through natural evaporation of water. Relative humidity level can be displayed. After the door is opened for 1 minute, temperature recovery time is less than or equal to 15 min at constant temperature of 37°C. Relative humidity can reach 95% through natural evaporation of water. Relative humidity level can be displayed. Volume Interior Dimension (WxDxH) 80L 150L 240L 400x450x500(mm) 480x530x610(mm) 600x630x670(mm) Overall Dimension (WxDxH) 590x687x790(mm) 670x767x880(mm) 788x837x940 (mm) 2/6 pieces 3/10 pieces 3/10 pieces / 3 glass door / Carrying Bracket Optional Sterilization Cycles 24hrs(90°C moist heat disinfection)24hrs(90°C moist heat disinfection) 24hrs(90°C moist heat disinfection) 0.5hrs(Ultra violet sterilization) 0.5hrs(Ultra violet sterilization) 0.5hrs(Ultra violet sterilization) Disinfection Method Disinfection methods include moist heat disinfection at temperature of 90°C and disinfection by ultraviole light. Users can choose one of the two methods based on specific applications. 90 Liquid Nitrogen Container Model E: Ultraviolet Sterilization System Biomedical Table Top Low Speed Large Capacity Centrifuge Specifications of LD-55T Rotors NO.1 NO.2 Angle rotor Horizontal rotor LD-55T NO.3 Superior performance Easy operation Controlled by a microcomputer, directly driven by AC variable frequency brushless motor with large torque, no carbon powder pollution, prolonged service life, several rotor options for users, large LCD screen, imported high-efficient fluoride-free refrigerating system, high speed centrifugation and low speed centrifugation with large capacity, diversified functions. Through touch panel, digital display and programmable operation, users can randomly set the centrifugal speed, time, RCF, speed change curve, 25 centrifugal programs for storage, modification and invocation. Through touch panel, digital display, programmable operation, users can randomly set the centrifugal speed, time, RCF and speed change curve, and 25 programs saving standard centrifugal program parameters. Model Max. speed Max. relative centrifugal force Max. capacity Optimal effect Timing scope 9 speed-up curves, 10 speed-down curves (No. 0 represents free parking), level 3 damper, and optimal centrifugal effect. Min. acceleration/ deceleration time Speed accuracy Automatic identification technology of rotor and several protections including overspeed, overtemperature, door closure self-locking, stainless steel inner bushing, three-layer protective jacket can ensure personnel and machine safety. 91 Order No. 5500r/min / 5310xg / / 50kg 300ml 100ml 19*5ml 3*50ml 7*20ml 9*15ml / 851409 Test glass 500ml 96x7ml 4000r/min 3040xg 851451 Hanging cup 4*24*7ml / / Adapter Adapter Adapter Adapter Adapter Adapter Adapter Adapter Horizontal hanging basket I 4000r/min 3040xg 85142 Square rack 4*2*96hole 4000r/min 3040xg 851495 Bucket rack 4*2*96 hole 2*2*96hole 4000r/min 2200xg 853810 4*100ml 5000r/min 4200r/min 4390xg 3100xg 853580 853540 Rack Pipe rack Pipe rack 2*2*96 hole 4*100ml 4*2*50ml / Adapter 36*2ml Adapter Adapter Adapter Adapter Adapter Adapter Adapter Adapter 50ml 50mlSharp 30ml 20ml 15ml 15mlSharp Vacuum tube Adapter Adapter hematocrit tube / / Adapter 50ml 50mlSharp 8*100ml NO.5 4200r/min 3100xg 853545 Pipe rack 4*2*100ml Adapter Adapter Adapter Adapter Adapter Horizontal rotor Adapter 32*15ml 64*5ml/7ml 4200r/min 4200r/min 3100xg 3100xg 853560 853550 Hexagonal, 4-opening 30ml 20ml 15ml 15mlSharp 3*5ml 2*10ml hematocrit tube Pipe rack 4*16*5ml/7ml / / / 5ml 48*5ml/7ml 4200r/min 3100xg 853555 Pipe rack 4*12*5ml/7ml / 24*20ml 4200r/min 3100xg 853565 Pipe rack 4*6*20ml / / 24*15ml 4200r/min 3100xg 853570 Pipe rack 4*6*15ml / / 16*20ml 4200r/min 3100xg 853575 4*4*20ml / / 92 Hexagonal, 4-opening 3*1.5ml 3*1.5ml 10ml 7ml 4*8*15ml Hexagonal, 2-opening 2*10ml Adapter Adapter Adapter Adapter Pipe rack Hexagonal 10*15mlSharp Hexagonal, 4-opening 10*15ml 20*10ml 25*1.5ml 28*5ml 4*5mlSharp 4*50ml 250ml / Adapter Adapter 55s/55s <65dB (A) 470x550x390 (mm) Adapter Adapter Adapter Adapter Adapter Adapter 3040xg 8*50ml 4x500ml 1min~99min (LED) 30s~99min59s(LCD) Noise Overall size (LxWxH) / 4000r/min 5310 xg ± 30r/min / 4x500ml 5500r/min Gross Power Net weight Horizontal rotor LD-55T AC 220 ± 22V 50Hz /60Hz 10A 1000W Power Safety and reliability NO.4 12*15ml Hanging Cup, Rack Max. speed Max. RCF and Basket Name Specification Name Specification Remarks Hexagonal, 4-opening Liquid Nitrogen Container Applicable to radiation immunity, biochemistry, bio-pharmaceuticals, blood separation and purification. 7 kinds of rotors available. Configure micro-rotor and PCR tube bank rotor. Rotor Rotor No. Name Capacity Biomedical Table Top High Speed Refrigerated Centrifuge Haier C02 incubators are widely applied to the research and production of medicine, immunology, genetics, microbiology, agricultural science and pharmacology, which is ideal experimental apparatus for in-vitro incubation of cells, tissue, microbes, etc. Parameters of LG-165TD Host Model LG-165TD Max. speed 16500r/min Max. relative centrifugal force 18360 xg Max. capacity 36x1.5/2.2ml Timing scope 30s~99min59s Temperature setting scope -20°C~40°C Temperature accuracy ±2.0°C Min. acceleration/decceleration time 50sec/50sec Speed accuracy ±50 r/min Compressor set Imported high performancecompressor unit, , fluoride-free refrigerant Supporting power supply AC 220±22V 50Hz10A Gross power 1000W Noise of machine <65dB (A) Overall dimension (LxWxH) 345x590x340(mm) φ 250mm Diameter ofcentrifugal chamber Net weight 70Kg LG-165TD Rotor No. NO.1 NO.2 Superior performance Rotor Name Capacity Max. Speed Max. RCF Angle rotor 12x1.5ml 16000r/min 17800xg Angle rotor 12x5ml 12000r/min 10142xg Easy operation Controlled by a microcomputer, directly driven by AC brushless variable frequency motor with large torque, with no carbon powder pollution, prolonged service life, large LCD screen, and several rotor options for users; Through touch panel, digital display, programmable operation, users can randomly set the centrifugal speed, time, RCF and speed change curve, and 25 programs saving standard centrifugal program parameters.. Optimal effect Safety and reliability 9 speed-up curves, 10 speed-down curves (No. 0 represents free parking), level 3 damper, special noise reduction technology, small noise and optimal centrifugal effect. Several protections including overspeed, misoperation, speed malfunction, frequency converter failure, door closure self-locking, stainless steel chamber, three-layer protective jacket can ensure personnel and machine safety. 93 NO.3 Angle rotor 24x1.5ml 13000r/min 16172xg Name Specifiction Adapter D.2ml Adapter 0.5ml Adapter 0.5ml Adapter 1.5ml Adapter 0.2ml Adapter 0.5ml NO.4 Angle rotor 3x8x0.2mlPCR strip 15000r/min 13800xg / / NO.5 Angle rotor 48x0.5ml 11000r/min 13700xg / / Adapter 0.2ml NO.6 Angle rotor 36x1.5ml 10000r/min 9178xg Adapter 0.5ml NO.7 Angle rotor 18x0.5ml 16000r/min 15300xg / / 94 Liquid Nitrogen Container Parameters of LG-165TD Rotors Biomedical Clean Bench light 95 96 Liquid Nitrogen Container CO2 Incubator Tube Type Lab Centrifuge