Olymp Heat Centre Multifuel in one square meter

Transcription

Olymp Heat Centre Multifuel in one square meter
Olymp Heat Centre
Multifuel in one square meter
DHW AND POOL
➟
HEATING
Solar &
Photovoltaic
Solar
➟
➟
Gas
Gas
➟
Heat Pump &
District heating
Erdwärme
➟
Wood
Holz
➟
➟
UNDERFLOOR
Pellets
➟
AND RADIATION
Up to
10%
Pellets
Oil
Öl
mo
annua re
effici l
ency
Heating systems
www.olymp.at
The requirements
for energy-efficient heating
Energy efficient heating. Boiler efficiency alone is only part of the all over efficiency of a heating
system. The different requirements and the new tasks of alternative energy integration set the need
for an all over view of the whole system. A good match of the various components in the heating
system set the base for efficient energy use.
Olymp provides the alternative to common systems to ensure a perfect use of the energy now and
in the future.
Solar
gain Solar
over the year
Ertrag
100
90
r
be
em
DEC
ez
N
1 - Environmentally friendly energy-mix
NOV
D
em
be
r
er
OCT
ov
O
kt
ob
SEP
Se
pt
em
be
r
st
AUG
gu
li
JUL
Au
JUN
Ju
ni
MAY
Ju
ai
Ap
APR
M
ril
z
MAR
är
r
ua
FEB
br
Fe
Jä
nn
JAN
M
er
90
80
70
5060
50
40
30
20
1010
0
Flexabillity provides independence. A personal energy mix is more than an alternative, it provides
security for the future.
2 - Heat distribution when it is needed
The energy generated has to be used at set times. This sounds logically simple, but is a complex
matter due to the different energy sources and levels. The Olymp system provides this logic with
the all over view of all sides of your heating system.
Energy
needEnergie
during the year
Bedarf
9090
be
r
em
em
NOV
D
ez
be
r
er
OCT
ob
kt
O
em
be
r
t
gu
s
SEP
N
ov
3 - Thermal buffer tank
AUG
pt
JUL
Se
JUN
Ju
li
MAY
Au
Ju
ni
ai
Ap
APR
M
ril
z
MAR
är
FEB
M
br
ua
r
JAN
Fe
Jä
nn
er
80
70
60
5050
40
30
20
1010
0
DEC
Energy has to be stored because the inputs and the outputs of the fuel is at different times and on
different levels. Energy is stored in the Olymp thermal store buffer with the advanced internal pipe
work. The different alternative energy sources like solar and wood are stored and the operation
mode for heat pumps, pellet boilers and other boiler types are better due to the decreased number
of starts.
2
Heating systems
Choo
se
your
o
energ wn
y-mix
3
Olymp 2-zone-heat-store
the update for your heating system
The instant DHW module provides a high flow rate with constant
temperatures. The temperature is limited to 50°C even if the storage tank
is heated up to 90°C with alternative energy sources like solar.
The HeizSchrank HS is with integrated gas or oil boiler and the SWS is
with external heat sources.
Olymp SWS 800
Olymp Heat Pump Heizschrank
with integrated system
The Olymp WHS 500 with RegelStar 3000. The new HeizSchrank generation with an
integrated heat pump is in combination with the instant DHW system and ensures high
performance even at higher temperature levels.
The Olymp Heat Pump HeizSchrank can be combined with other heat sources and can also be
used for passive cooling.
The advantages of the WHS 500
> Higher temperatures
up to 60°C are achieved without the use of an immersion
heater
> Quiet operation
> Efficient with better annual performance
> Plentiful hot water
The DHW is produced 100% without legionella
> High quality components
> Compact design
> Easy service
> Solar possible
> Passive cooling possible
> Additional option for peak demand with electric
immersion heater
Heating systems
4
Olymp Multi-fuel-Heizschrank
the compact thermal store with energy management controller
The Olymp HS & SHS – a compact solution. The combination of the integrated
heating circuits and instant domestic hot water with the thermal store and integration
options with alternative energy sources as well as standard boilers provides a very
flexible solution now and for the future. The integrated controller manages the
outside temperature regulated heating circuits (weather compensation) as well as the
combination of different heat sources such as gas, solar, biomass.
Olymp SHS 730
Condensing Unit
Heating with low emission
The ceramic condensing unit provides low flue gas temperatures and therefore efficient operation.
The ceramic condensing unit can be used with all gas and oil qualities and gives high performance
throughout all operating heat sources as gas, solar or biomass.
Condensing unit
OIL and GAS
Combustion losses comparison
250-300 °C
Old
Boiler
5
200 °C
Boiler
(until ~1980)
180 °C
Old
Boiler
Heating systems
LRV 92
Swiss
regulation
Lowtemperature
15 %
10 %
OIL
GAS
13 %
OIL
GAS
OIL
GAS
14%
18 %
19 %
20 %
OIL
GAS
OIL
GAS
15 %
17-24 %
22-29 %
%
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
120 -160 °C
Special
Low-Nox
technique
GAS + OIL
1- 3 %
30-70 °C
BrennwertStar
(for oil and gas)
One control for everything
Olymp RegelStar 3000
„Complex systems need a simple solution“.
Olymp has introduced a new controls generation with the RegelStar 3000. The RZ 3000 is an
integrated concept for all heating and cooling needs. The main task of this modern concept is the
integration of all different heat sources in combination with a comfortable heat distribution.
RegelStar 3000
Classic remote control
Comfort remote control
A simple room control to alter the room
temperature and change the operating mode.
SOLAR
control
buffer
heating circuit
management
Complete setting and information levels are
easily done with this remote control.
The special AEB (alternative energy button)
function allows the efficient use of alternative
energy like solar and wood. A wireless version
is available.
MOBILe
DHW
regulation
COMMUNICATION
access
GEOTHERMAL
ALTERNATIV
energy button
biomass
Schematic example with an
Olymp Heizschrank
Art.Nr. WM0313172
Literal and phrase mistakes excepted, all information without engagement!
P
Solarstation
primary+secondary
T
T
P
M
WWHK
MHK
The
O
part lymp
ner
will
pr
ovid
e th
righ
e
t sc
h
for y emata
ou!
Pool
M
EXP
HolzStar
Lambda
SunStar
HP
Solar-Heizschrank
SHS
Heating systems
Solar
solar
Holz
wood
Pellets
pellets
Wärmepumpe
heat pump
Gas
gas
Öl
oil
Heizkörper
radiators
one
4all
Solar
Pellets
Wärmepumpe
Gas
Holz
Öl
HeizZentrale
OLYMP Werk GmbH I Olympstr. 10 I 6430 Ötztal-Bahnhof I Österreich I T +43 (0)5266 8910 I [email protected] I www.olymp.at