JULY, 2016 1600 SS Curtain Wall System Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-099 FEATURES Features • 1600 SS is an outside glazed captured or SSG curtain wall system • 1600 SS has 2-1/2" (63.5) sight lines • Standard 6" (152.4) or 7-1/2" (190.5) depth systems • Standard infill options 1/4" (6.4) and 1" (25.4), other infills available • Thermally Broken by means of a continuous 1/4" (6.4) low conductance spacer • A pre-glazed option, 1600 SS (Preglazed), is also available • Perimeter seal can be installed at the pressure plate or mullion shoulder • 1600 SS can be supplied fabricated and KD or in stock lengths • Interlocking mullion design eliminates need for anti-buckling clips • Concealed fastener joinery creates smooth, monolithic appearance • EPDM gaskets and thermal break • Screw spline joinery method allows shop assembly of ladder sections, reducing field labor • Corners available with shear block fabrication method • Offers integrated entrance framing systems • Silicone compatible glazing materials for long-lasting seals • Two color option • PermanodicTM anodized finishes in seven choices © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. • Painted finishes in standard and custom choices Optional Features • Captured system thermal separator can be pre-installed into pressure plate • Fiberglass pressure plates available • Captured and SSG systems with standard Kawneer windows and GLASSventTM windows for curtain wall • Captured system Integrates with standard Kawneer windows • Deep and bullnose covers available • Integrates with VersoleilTM SunShade Outrigger System and Horizontal or Vertical Single Blade System • Profit$MakerTM plus die sets available Product Applications • Ideal for low to mid-rise applications where high performance is desired • Most of the product assembly can be done in the shop rather than the field. This allows for better quality control and reduces expensive field labor. For specific product applications, Consult your Kawneer representative. kawneer.com ADMD060EN 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS Curtain Wall System BLANK PAGE ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 EC 97911-099 JULY, 2016 JULY, 2016 1600 SS Curtain Wall System EC 97911-099 3 INDEX Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. BACK PAN DETAILS..........................................................................17 ANCHORING.................................................................................18,19 WIND LOAD / DEAD LOAD CHARTS......................................... 20-25 THERMAL CHARTS .................................................................... 26-41 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PICTORIAL VIEW.................................................................................5 CAPTURED MULLION FRAMING DETAILS.......................................6 SSG MULLION FRAMING DETAILS....................................................7 ENTRANCE DETAILS.......................................................................8,9 UNITWALL FRAMING DETAILS........................................................10 (RTS) CAPTURED MULLION FRAMING DETAILS......................11,12 ENTRANCE DETAILS (RTS)..............................................................13 CORNER DETAILS........................................................................14,15 GLASSventTM WINDOWS FOR CURTAIN WALL/WINDOWS...........16 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD060EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS Curtain Wall System BLANK PAGE ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 EC 97911-099 JULY, 2016 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 kawneer.com 1600 SS Curtain Wall System EC 97911-099 PICTORIAL VIEW ADMD060EN 5 PERIMETER PRESSURE PLATE 6 8 3 7 9 9A ENTRANCE DETAILS 4 4A 5 5A OPTIONAL FIBERGLASS PRESSURE PLATE ADMD060EN 1 6" (152.4) 7-1/2" (190.5) 1 1A 2 2 ANCHOR DETAILS 4 ELEVATION IS NUMBER KEYED TO DETAILS 4A 5A 5 PERIMETER PRESSURE PLATE PERIMETER MULLION kawneer.com © Kawneer Company, Inc., 2014 CAPTURED MULLION FRAMING DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1/2" (12.7) 1600 SS Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1A 2-1/2" (63.5) 6 EC 97911-099 JULY, 2016 SCALE 3" = 1'-0" PERIMETER MULLION 3 CORNER DETAILS © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7 1/2" (12.7) kawneer.com 6" (152.4) 7-1/2" (190.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 1600 SS Curtain Wall System EC 97911-099 SCALE 3" = 1'-0" 6, 6A 7, 7A 11 ENTRANCE DETAILS 6 7A 4 4A 6A 8 9 ADMD060EN 9A 2-1/2" (63.5) OPTIONAL FIBERGLASS PRESSURE PLATE 7 SSG MULLION FRAMING DETAILS 1 1A 2 2A ANCHOR DETAILS 10 3 CORNER DETAILS 5 5A ELEVATION IS NUMBER KEYED TO DETAILS 10 11 2-1/2" (63.5) 2-1/2" (63.5) 3 2 2-1/2" (63.5) 2-1/2" (63.5) 3/4" (19.0) ADMD060EN 1 C/H ELEVATION IS NUMBER KEYED TO DETAILS BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER TRANSOM BAR 7-1/2" (190.5) 6" (152.4) 3/4" (19.0) BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING OFFSET ARM CONCEALED OVERHEAD CLOSER TRANSOM BAR DOOR JAMB 7-1/2" (190.5) CENTER HUNG 6" (152.4) 4 3 TRANSOM BAR CENTER HUNG WITH CONCEALED OVER HEAD CLOSER kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. ENTRANCE DETAILS © Kawneer Company, Inc., 2014 DOOR JAMB BUTT HUNG OR OFFSET PIVOT 1-3/4" (63.5) 1/8" (3.2) 1600 SS Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. B/H or O/P 2-1/2" (63.5) 2 1-3/4" (63.5) 1/8" (3.2) 6" (152.4) 7-1/2" (190.5) 1 1-3/4" (63.5) 1/8" (3.2) 6" (152.4) 7-1/2" (190.5) 8 EC 97911-099 JULY, 2016 SCALE 3" = 1'-0" 7-1/2" (190.5) 6" (152.4) 4 1A 1600 SS Curtain Wall System JULY, 2016 EC 97911-099 ENTRANCE DETAILS SCALE 3" = 1'-0" 5 7-1/2" (190.5) 2-1/2" (63.5) 6" (152.4) B/H or O/P 5 Optional Interior Cover ELEVATION IS NUMBER KEYED TO DETAILS FLUSH TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER FLUSH DOOR JAMB BUTT HUNG OR OFFSET PIVOT 6 7-1/2" (190.5) 6" (152.4) 6" (152.4) 2-1/2" (63.5) 7-1/2" (190.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6 5A Optional Interior Cover 2-1/2" (63.5) BUTT HUNG OR OFFSET PIVOT 6 7-1/2" (190.5) 6" (152.4) 6" (152.4) 2-1/2" (63.5) 7-1/2" (190.5) ALTERNATE SSG FLUSH DOOR JAMB 5B 2-1/2" (63.5) FLUSH TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER ALTERNATE SSG DOOR JAMB 6 2-1/2" (63.5) kawneer.com BUTT HUNG OR OFFSET PIVOT 6" (152.4) 7-1/2" (190.5) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. FLUSH TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH LCN 2030 COC CLOSER 3/4" (19.0) ADMD060EN 9 3" (76.2) PERIMETER PRESSURE PLATE 1A 1 1A 6 7 4 9 4A ADMD060EN 1 6" (152.4) 7-1/2" (190.5) 2A 8 3 5 5A ELEVATION IS NUMBER KEYED TO DETAILS 3 4A 4 5A 5 PERIMETER PRESSURE PLATE PERIMETER MULLION kawneer.com © Kawneer Company, Inc., 2014 UNITWALL FRAMING DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1/2" (12.7) SCALE 3" = 1'-0" 2-1/2" (63.5) 1600 SS Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 2A 3" (76.2) 10 EC 97911-099 JULY, 2016 NOTE: SEE PAGE 7 FOR VERTICAL MULLION DETAILS PERIMETER MULLION 2 © Kawneer Company, Inc., 2014 3" (76.2) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2 6 7 kawneer.com 3" (76.2) 1/2" (12.7) EC 97911-099 SCALE 3" = 1'-0" 1A 9 ENTRANCE DETAILS 2-1/2" (63.5) JULY, 2016 1600 SS Curtain Wall System (RTS) CAPTURED MULLION FRAMING DETAILS (RTS) - Reversed Thermal Separator PERIMETER PRESSURE PLATE PERIMETER MULLION 1 1A CORNER DETAILS 4 ADMD060EN 1 6" (152.4) 7-1/2" (190.5) 2A ANCHOR DETAILS 3 8 2 5 5A ELEVATION IS NUMBER KEYED TO DETAILS 3 4A 4 5A 5 PERIMETER PRESSURE PLATE PERIMETER MULLION 11 1/2" (12.7) 2-1/2" (63.5) (RTS) CAPTURED MULLION FRAMING DETAILS 6 8 7 9 ADMD060EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS Curtain Wall System kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SCALE 3" = 1'-0" 6" (152.4) 7-1/2" (190.5) 12 EC 97911-099 JULY, 2016 (RTS) - Reversed Thermal Separator 1600 SS Curtain Wall System JULY, 2016 EC 97911-099 ENTRANCE DETAILS (RTS) SCALE 3" = 1'-0" (RTS) - Reversed Thermal Separator 1 1-3/4" (63.5) 2-1/2" (63.5) 1/8" (3.2) 4 1 C/H B/H or O/P (RTS) ENTRANCE ELEVATION TRANSOM BAR ELEVATION IS NUMBER KEYED TO DETAILS BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER 7-1/2" (190.5) 6" (152.4) DOOR JAMB BUTT HUNG OR OFFSET PIVOT 2 6" (152.4) 1-3/4" (63.5) 1/8" (3.2) 7-1/2" (190.5) 1A TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING OFFSET ARM CONCEALED OVERHEAD CLOSER 2-1/2" (63.5) 3/4" (19.0) 7-1/2" (190.5) 6" (152.4) DOOR JAMB CENTER HUNG 3 TRANSOM BAR 2-1/2" (63.5) CENTER HUNG WITH CONCEALED OVER HEAD CLOSER kawneer.com 4 6" (152.4) 1-3/4" (63.5) 7-1/2" (190.5) 2-1/2" (63.5) 1/8" (3.2) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 2 2-1/2" (63.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 7-1/2" (190.5) 6" (152.4) ADMD060EN 3/4" (19.0) 13 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS Curtain Wall System CORNER DETAILS 90° OUTSIDE CORNER 90° INSIDE CORNER 90° OUTSIDE CORNER (RTS) 90° INSIDE CORNER (RTS) ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 EC 97911-099 JULY, 2016 SCALE 3" = 1'-0" © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 kawneer.com 1600 SS Curtain Wall System EC 97911-099 CORNER DETAILS SCALE 3" = 1'-0" 90° OUTSIDE CORNER 135° OUTSIDE CORNER 90° OUTSIDE SSG CORNER 90° INSIDE SSG CORNER 135° OUTSIDE SSG CORNER 135° INSIDE SSG CORNER ADMD060EN 15 HEAD SILL GLASSventTM WINDOWS FOR CURTAIN WALL/WINDOWS HEAD SILL JAMB AT CAPTURED MULLION ADMD060EN JAMB AT SSG MULLION Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS Curtain Wall System JAMB kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 16 EC 97911-099 JULY, 2016 SCALE 3" = 1'-0" GLASSventTM WINDOWS FOR CURTAIN WALL 8225TL THERMAL WINDOWS NOTE: Other vent types can be accommodated. Contact your Kawneer representative for other options. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 kawneer.com 2 ELEVATION IS NUMBER KEYED TO DETAILS 1 JAMB MULLION AT SPANDREL 3/4" (19.1) 3" (76.2) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 1600 SS Curtain Wall System EC 97911-099 BACKPAN DETAILS SCALE 3" = 1'-0" 3 3 4 5 HEAD 6 4 NOTE: 7-1/2" SYSTEM SHOWN, 6" SYSTEM SIMILAR EXPANSION JOINT 5 2 TYPICAL DEADLOAD ANCHOR 2-1/2" (63.5) MULLION AT SPANDREL 6 TRANSOM – SPANDREL OVER VISION ADMD060EN 17 1" (25.4) MINIMUM ANCHORING TO FLOOR SLAB 1" (25.4) MINIMUM ANCHORING TO SUPPORT STEEL ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 ANCHORING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 EC 97911-099 JULY, 2016 Actual project conditions will determine specific anchor design. Details on this page are for reference only. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 kawneer.com 1600 SS Curtain Wall System EC 97911-099 ANCHORING Actual project conditions will determine specific anchor design. Details on this page are for reference only. 1" (25.4) MINIMUM ANCHORING TO HORIZONTAL STRUCTURAL STEEL 1" (25.4) MINIMUM ANCHORING TO VERTICAL STRUCTURAL STEEL ADMD060EN 19 20 1600 SS Curtain Wall System WIND LOAD / DEAD LOAD CHARTS JULY, 2016 EC 97911-099 DEADLOAD CHARTS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown. ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. A conversion from Load Resistance Factor Design (LRFD) is provided. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS 1600 SS Curtain Wall System JULY, 2016 EC 97911-099 WIND LOAD CHARTS (1" INFILL) SINGLE SPAN A= B= C= D= E= MULLION CENTERS IN METERS 1.0 2.0 20 6.0 18 TWIN SPAN LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) MULLION CENTERS IN METERS 2.0 9.0 29 28 10 3.0 9 B 8 C D 2.0 E 6 EQUAL 24 23 7.0 A 22 21 20 6.0 19 B 18 17 MULLION HEIGHT IN METERS A 25 MULLION HEIGHT IN FEET 11 MULLION HEIGHT 12 EQUAL 4.0 13 MULLION HEIGHTT 14 8.0 26 MULLION HEIGHT IN METERS 15 7 5.0 16 C 15 5 D 14 4 1.0 0 1 2 3 4 5 6 7 4.0 13 169001 8 169002 12 I = 5.652 (235.25 x 104) S = 1.954 (32.02 x 103) MULLION CENTERS IN FEET E 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 2.0 20 18 28 4.0 13 A 12 B 11 C 10 3.0 9 D E 8 7 2.0 6 9.0 A 8.0 26 25 24 B 23 7.0 22 21 C 20 6.0 19 18 D 17 5.0 16 E 15 5 14 4 1.0 3 2 2.0 27 MULLION HEIGHT IN FEET 14 MULLION HEIGHT 15 MULLION HEIGHT IN METERS 5.0 EQUAL 17 EQUAL 29 MULLION HEIGHT 19 16 1.0 30 6.0 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com 4.0 13 169003 169004 I = 11.512 (479.16 x 104) S = 3.141 (51.47 x 103) ADMD060EN 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION HEIGHT IN METERS 3 MULLION HEIGHT IN FEET 1.0 30 5.0 16 2 © Kawneer Company, Inc., 2014 Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) 27 17 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 19 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 21 1600 SS Curtain Wall System JULY, 2016 WIND LOAD CHARTS (1" INFILL) 1.0 20 2.0 6.0 19 18 TWIN SPAN LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) MULLION CENTERS IN METERS 27 11 10 3.0 9 E 8 D C 7 A B EQUAL 2.0 24 23 7.0 22 A 21 B E 20 6.0 C 19 D 18 17 5.0 16 15 5 14 4 1.0 0 1 2 3 4 5 6 7 4.0 13 169005 8 12 169006 I = 3.609 (150.22 x 104) S = 1.773 (29.05 x 103) MULLION CENTERS IN FEET 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN MULLION CENTERS IN METERS MULLION CENTERS IN METERS 2.0 1.0 20 18 28 4.0 13 12 A E 11 B D C 10 3.0 9 8 7 2.0 6 2.0 9.0 27 A 8.0 26 E 25 MULLION HEIGHT IN FEET 14 MULLION HEIGHT 15 MULLION HEIGHT IN METERS 5.0 EQUAL 17 EQUAL 29 MULLION HEIGHT 19 16 1.0 30 6.0 B D C 24 23 7.0 22 21 20 6.0 19 18 17 MULLION HEIGHT IN METERS 3 5.0 16 15 5 14 4 1.0 3 2 MULLION HEIGHT IN METERS 12 25 MULLION HEIGHT IN FEET 13 MULLION HEIGHT 4.0 EQUAL 14 MULLION HEIGHT 15 8.0 26 MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 9.0 28 5.0 6 MULLION HEIGHT IN FEET 2.0 29 17 16 2 1.0 30 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET 4.0 13 169007 169008 I = 8.065 (335.69 x 104) S = 2.842 (46.57 x 103) ADMD060EN 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com © Kawneer Company, Inc., 2014 A= B= C= D= E= MULLION CENTERS IN METERS Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN EC 97911-099 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 22 1600 SS Curtain Wall System JULY, 2016 EC 97911-099 DEAD LOAD CHARTS (1/4" INFILL) (1" INFILL) SPAN IN METERS SPAN IN METERS A = 1/4 POINT LOADING B = 1/8 POINT LOADING 2.0 7 2.0 A 6 5 4 1.0 3 2 169014 8 7 3 4 5 6 7 B 5 4 1.0 3 0 2 2.0 6 A 1 0 1 3.0 9 2 I = 1.620 (67.43 x 104) S = 1.296 (21.24 x 103) 1 10 8 0 1 SPAN IN FEET 4 5 6 7 8 2.0 SPAN IN METERS 1.0 13 12 12 11 11 10 3.0 9 8 A 7 2.0 6 5 4 1.0 3 2 169017 I = 2.052 (85.41 x 104) S = 1.642 (26.91 x 103) 1 GLASS HEIGHT IN FEET 13 GLASS HEIGHT IN METERS GLASS HEIGHT IN FEET © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 (1" INFILL) A = 1/4 POINT LOADING B = 1/8 POINT LOADING SPAN IN METERS 0 2 SPAN IN FEET (1/4" INFILL) 1.0 2.0 10 3.0 9 8 B 7 2.0 6 5 4 A 1.0 3 2 1 0 1 2 3 4 5 6 7 0 8 SPAN IN FEET kawneer.com GLASS HEIGHT IN METERS 8 GLASS HEIGHT IN FEET 3.0 9 11 GLASS HEIGHT IN METERS 10 2.0 12 B 11 GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 12 1.0 13 0 1 2 3 4 5 6 SPAN IN FEET ADMD060EN 7 8 GLASS HEIGHT IN METERS 1.0 13 0 23 1600 SS Curtain Wall System JULY, 2016 DEAD LOAD CHARTS (1/4" INFILL) (1" INFILL) SPAN IN METERS SPAN IN METERS A = 1/4 POINT LOADING B = 1/8 POINT LOADING 11 3.0 9 8 7 2.0 6 5 B 4 1.0 3 A 2 GLASS HEIGHT IN FEET 12 11 GLASS HEIGHT IN METERS 12 10 169016 I = 0.589 (24.52 x 104) S = 0.456 (7.47 x 103) 1 0 10 3.0 9 8 7 2.0 6 5 4 1.0 3 2 B 1 A 0 3 4 5 6 7 0 8 1 2 SPAN IN FEET (1/4" INFILL) 4 5 6 7 8 (1" INFILL) A = 1/4 POINT LOADING B = 1/8 POINT LOADING SPAN IN METERS 2.0 1.0 3 SPAN IN FEET SPAN IN METERS 12 11 11 3.0 9 8 7 2.0 6 5 B 4 1.0 3 A 169019 I = 0.598 (24.89 x 104) S = 0.470 (7.70 x 103) GLASS HEIGHT IN FEET 12 GLASS HEIGHT IN METERS 13 10 2.0 1.0 13 10 3.0 9 8 7 2.0 6 5 4 1.0 3 2 B 1 1 A 0 0 2 0 1 2 3 4 5 6 7 0 8 SPAN IN FEET 1 2 3 4 5 6 7 8 SPAN IN FEET ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 GLASS HEIGHT IN METERS 0 GLASS HEIGHT IN FEET 2.0 1.0 13 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2.0 1.0 13 GLASS HEIGHT IN FEET EC 97911-099 GLASS HEIGHT IN METERS 24 1600 SS Curtain Wall System JULY, 2016 DEAD LOAD CHARTS (1/4" INFILL) (1" INFILL) SPAN IN METERS SPAN IN METERS A = 1/4 POINT LOADING B = 1/8 POINT LOADING 2.0 1.0 11 3.0 9 8 7 2.0 6 5 B 4 1.0 3 A 2 169015 GLASS HEIGHT IN FEET 12 11 10 I = 0.659 (27.43 x 104) S = 0.496 (8.13 x 103) 1 10 3.0 9 8 7 2.0 6 5 4 1.0 3 2 B 1 A 0 0 1 2 3 4 5 6 7 0 8 1 5 6 7 8 SPAN IN METERS 12 12 11 11 3.0 9 8 7 2.0 6 5 B 4 1.0 3 A 2 169018 I = 0.671 (27.93 x 104) S = 0.514 (8.42 x 103) 1 GLASS HEIGHT IN FEET 13 10 2.0 1.0 13 GLASS HEIGHT IN METERS GLASS HEIGHT IN FEET 4 (1" INFILL) A = 1/4 POINT LOADING B = 1/8 POINT LOADING 2.0 1.0 3 SPAN IN FEET SPAN IN METERS © Kawneer Company, Inc., 2014 2 SPAN IN FEET 10 3.0 9 8 7 2.0 6 5 4 1.0 3 B 2 A 1 0 0 0 1 2 3 4 5 6 7 0 8 SPAN IN FEET kawneer.com 1 2 3 4 5 6 SPAN IN FEET ADMD060EN 7 8 GLASS HEIGHT IN METERS 0 (1/4" INFILL) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2.0 1.0 13 12 GLASS HEIGHT IN METERS GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 13 GLASS HEIGHT IN METERS EC 97911-099 25 1600 SS Curtain Wall System 26 JULY, 2016 THERMAL CHARTS EC 97911-099 Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) (Based on single bay of Curtain Wall/Window Wall) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5'-0" D.L.O. Vision Area Example Glass U-factor = 0.48 Btu/(ft2 · h · °F) Vision Area = 5(9 + 8 + 4) = 105.0 ft2 Total Area (Vision) = 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2 Percentage of Vision Glass = (Vision Area ÷ Total Area)100 = (105.0 ÷ 113.2)100 = 93% Spandrel Area Example Spandrel R-value = 15 (ft2 · h · °F)/Btu Spandrel Area = 5(6 + 3) = 45.0 ft2 Total Area (Spandrel) = 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2 Percent of Spandrel = (Spandrel Area ÷ Total Area)100 = (49.0 ÷ 49.6)100 = 91% ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 VISION Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8'-0" D.L.O. SPANDREL 31'-3" VISION 6'-0" D.L.O. VISION 2-1/2" Typ. SPANDREL 9'-0" D.L.O. 4'-0" 3'-0" D.L.O. D.L.O. 2-1/2" Typ. 1600 SS Curtain Wall System JULY, 2016 EC 97911-099 27 THERMAL CHARTS Vision Area Chart System U-factor vs Percent of Vision Area 0.80 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. T COG U-factor 0.53 0.50 0.40 0.30 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 Btu h·ft 2·°F System U-factor O E IGN PL S M E A D EX OR F (N 0.70 93% 0.20 95 85 90 75 80 70 Vision Area / Total Area (%) Based on a single curtain wall bay of 93% vision glass and center of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F) System U-factor vs Percent of Spandrel Area Spandrel R-value E IGN PL S M E A D EX OR F O 0.50 T 3.00 4.00 © Kawneer Company, Inc., 2014 5.00 0.21 0.20 0.10 91% 95 0.30 ) 11.00 15.00 19.00 30.00 0.40 Btu h·ft 2·°F System U-factor 2.00 0.60 (N Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Spandrel Area Chart 90 85 80 75 70 Spandrel Area / Total Area (%) Based on a single curtain wall bay of 91% spandrel and center of spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F) kawneer.com ADMD060EN 1600 SS Curtain Wall System JULY, 2016 THERMAL CHARTS (CAPTURED) EC 97911-099 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. System U-Factor for Vision Glass 0.90 (5.00) 0.80 0.70 (4.50) (4.00) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.55 (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) 0.50 0.45 (3.50) 2 Btu h·ft 2·°F 0.60 COG U-factor ( m W·°C ) 0.65 System U-Factor 0.75 (3.00) (2.50) 0.40 0.35 (2.00) 0.30 0.25 (1.50) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.85 0.20 85 80 Vision Area / Total Area (%) 75 70 System U-Factors for Spandrel Glass 0.70 (4.00) 0.65 0.60 (3.50) 0.55 3.00 (0.53) 0.35 4.00 (0.70) 0.30 5.00 (0.88) 0.25 System U-Factor 0.40 (2.50) 2 0.45 2.00 (0.35) (3.00) ( m W·°C ) 0.50 Spandrel R-Value (2.00) (1.50) 0.20 (2.00) 11.00 (1.94) 0.15 15.00 (2.64) 0.10 19.00 (3.34) (1.50) 30.00 (5.28) 0.05 95 90 85 80 75 70 Spandrel Area / Total Area (%) ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 90 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 95 Btu h·ft 2·°F 28 1600 SS Curtain Wall System JULY, 2016 EC 97911-099 THERMAL CHARTS (CAPTURED) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC 0.90 0.90 0.85 0.85 0.80 0.80 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 29 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.10 95 90 80 85 75 70 Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT 0.90 0.90 0.85 0.85 0.80 0.80 0.75 0.75 0.70 0.70 0.65 0.65 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.10 95 90 80 85 Vision Ares / Total Area (%) Charts are generated per AAMA 507. kawneer.com ADMD060EN 75 70 System VT 0.60 0.60 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Charts are generated per AAMA 507. 1600 SS Curtain Wall System JULY, 2016 THERMAL PERFORMANCE MATRIX (NFRC SIZE) - (CAPTURED) 0.48 0.62 0.46 0.60 0.44 0.59 0.42 0.57 0.40 0.55 0.38 0.54 0.36 0.52 0.34 0.50 0.32 0.49 0.30 0.47 0.28 0.46 0.26 0.44 0.24 0.42 0.22 0.41 0.20 0.39 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.90 0.82 0.90 0.81 0.85 0.78 0.85 0.76 0.80 0.73 0.80 0.72 0.75 0.69 0.75 0.67 0.70 0.64 0.70 0.63 0.65 0.60 0.65 0.58 0.60 0.55 0.60 0.54 0.55 0.51 0.55 0.49 0.50 0.46 0.50 0.45 0.45 0.42 0.45 0.40 0.40 0.37 0.40 0.36 0.35 0.33 0.35 0.31 0.30 0.29 0.30 0.27 0.25 0.24 0.25 0.22 0.20 0.20 0.20 0.18 ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 Overall U-Factor 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1" GLAZING WITH ALUMINUM PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 EC 97911-099 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 30 1600 SS Curtain Wall System JULY, 2016 EC 97911-099 31 THERMAL CHARTS (SSG) Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. System U-Factor for Vision Glass 0.90 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.85 (5.00) 0.80 0.70 (4.50) (4.00) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.55 (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) 0.50 0.45 (3.50) 2 Btu h·ft 2·°F 0.60 COG U-factor ( m W·°C ) 0.65 System U-Factor 0.75 (3.00) (2.50) 0.40 0.35 (2.00) 0.30 0.25 (1.50) 0.20 90 85 80 Vision Area / Total Area (%) 75 70 System U-Factors for Spandrel Glass 0.70 (4.00) 0.65 0.60 (3.50) 0.55 0.40 0.35 3.00 (0.53) (2.50) (2.00) 0.30 4.00 (0.70) 0.25 5.00 (0.88) (1.50) 0.20 (2.00) 11.00 (1.94) 0.15 15.00 (2.64) 19.00 (3.34) 0.10 30.00 (5.28) 95 0.05 90 85 80 Spandrel Area / Total Area (%) kawneer.com ADMD060EN 75 70 System U-Factor 2.00 (0.35) 2 Btu h·ft 2·°F 0.45 (3.00) ( m W·°C ) 0.50 Spandrel R-Value © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 95 (1.50) 1600 SS Curtain Wall System JULY, 2016 THERMAL CHARTS (SSG) EC 97911-099 0.90 0.85 0.85 0.80 0.80 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 System SHGC 0.90 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC 0.15 0.10 95 90 80 85 75 70 Vision Area / Total Area (%) Charts are generated per AAMA 507. 0.90 0.85 0.85 0.80 0.80 0.75 0.75 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.90 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.10 95 90 80 85 75 70 Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 System Visible Transmittance (VT) vs Percent of Vision Area COG VT System VT 32 1600 SS Curtain Wall System JULY, 2016 EC 97911-099 THERMAL PERFORMANCE MATRIX (NFRC SIZE) - (SSG) 1" GLAZING WITH ALUMINUM PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.56 0.46 0.54 0.44 0.53 0.42 0.51 0.40 0.49 0.38 0.48 0.36 0.46 0.34 0.44 0.32 0.42 0.30 0.41 0.28 0.39 0.26 0.37 0.24 0.36 0.22 0.34 0.20 0.32 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SHGC Matrix 2 kawneer.com 33 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.90 0.87 0.90 0.81 0.85 0.82 0.85 0.77 0.80 0.77 0.80 0.72 0.75 0.73 0.75 0.68 0.70 0.68 0.70 0.63 0.65 0.64 0.65 0.59 0.60 0.59 0.60 0.54 0.55 0.55 0.55 0.50 0.50 0.50 0.50 0.45 0.45 0.46 0.45 0.41 0.40 0.41 0.40 0.36 0.35 0.37 0.35 0.32 0.30 0.32 0.30 0.27 0.25 0.28 0.25 0.23 0.20 0.23 0.20 0.18 ADMD060EN 1600 SS Curtain Wall System 34 THERMAL CHARTS (CAPTURED - FIBERGLASS PRESSURE PLATE) JULY, 2016 EC 97911-099 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. 1" GLAZING WITH FIBERGLASS PRESSURE PLATE COG U-factor 0.48 (2.72) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 System U-Factor (Btu/h·ft2·°F) Vision Area / Total Area (%) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. EC 97911-099 0.45 0.40 0.35 kawneer.com System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 1600 SS Curtain Wall System 0.30 0.25 0.20 0.15 0.10 0.05 Charts are generated per AAMA 507. ADMD060EN 35 THERMAL CHARTS (CAPTURED - FIBERGLASS PRESSURE PLATE) 1" GLAZING WITH FIBERGLASS PRESSURE PLATE System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) COG SHGC 0.75 0.70 0.65 0.60 0.55 0.50 0.30 0.25 0.20 0.15 0.10 0.05 Charts are generated per AAMA 507. THERMAL CHARTS (CAPTURED - FIBERGLASS PRESSURE PLATE) System Visible Transmittance (VT) vs Percent of Vision Area Vision Ares / Total Area (%) COG VT 0.75 0.70 0.65 0.60 0.55 0.50 0.40 0.35 ADMD060EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS Curtain Wall System kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.45 System VT 36 EC 97911-099 JULY, 2016 1" GLAZING WITH FIBERGLASS PRESSURE PLATE 1600 SS Curtain Wall System JULY, 2016 EC 97911-099 THERMAL PERFORMANCE MATRIX (NFRC SIZE) CAPTURED - FIBERGLASS PRESSURE PLATE 1" GLAZING WITH FIBERGLASS PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.56 0.46 0.54 0.44 0.52 0.42 0.51 0.40 0.49 0.38 0.47 0.36 0.46 0.34 0.44 0.32 0.43 0.30 0.41 0.28 0.39 0.26 0.38 0.24 0.36 0.22 0.34 0.20 0.33 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 37 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.68 0.75 0.67 0.70 0.64 0.70 0.63 0.65 0.59 0.65 0.58 0.60 0.55 0.60 0.54 0.55 0.50 0.55 0.49 0.50 0.46 0.50 0.45 0.45 0.41 0.45 0.40 0.40 0.37 0.40 0.36 0.35 0.33 0.35 0.31 0.30 0.28 0.30 0.27 0.25 0.24 0.25 0.22 0.20 0.19 0.20 0.18 0.15 0.15 0.15 0.13 0.10 0.10 0.10 0.09 0.05 0.06 0.05 0.04 ADMD060EN 1600 SS Curtain Wall System 38 THERMAL CHARTS (SSG - FIBERGLASS PRESSURE PLATE) JULY, 2016 EC 97911-099 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. 1" GLAZING WITH FIBERGLASS PRESSURE PLATE COG U-factor 0.48 (2.72) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 System U-Factor (Btu/h·ft2·°F) Vision Area / Total Area (%) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. EC 97911-099 COG SHGC 0.40 0.35 0.30 kawneer.com System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 1600 SS Curtain Wall System 0.25 0.20 0.15 0.10 0.05 Charts are generated per AAMA 507. ADMD060EN 39 THERMAL CHARTS (SSG - FIBERGLASS PRESSURE PLATE) 1" GLAZING WITH FIBERGLASS PRESSURE PLATE System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.30 0.25 0.20 0.15 0.10 0.05 Charts are generated per AAMA 507. THERMAL CHARTS (SSG - FIBERGLASS PRESSURE PLATE) System Visible Transmittance (VT) vs Percent of Vision Area Vision Ares / Total Area (%) COG VT 0.75 0.70 0.65 0.60 0.55 0.50 0.40 0.35 ADMD060EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS Curtain Wall System kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.45 System VT 40 EC 97911-099 JULY, 2016 1" GLAZING WITH FIBERGLASS PRESSURE PLATE 1600 SS Curtain Wall System JULY, 2016 EC 97911-099 THERMAL PERFORMANCE MATRIX (NFRC SIZE) SSG - FIBERGLASS PRESSURE PLATE 1" GLAZING WITH FIBERGLASS PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.54 0.46 0.53 0.44 0.51 0.42 0.49 0.40 0.48 0.38 0.46 0.36 0.44 0.34 0.42 0.32 0.41 0.30 0.39 0.28 0.37 0.26 0.36 0.24 0.34 0.22 0.32 0.20 0.31 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 41 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.73 0.75 0.68 0.70 0.69 0.70 0.63 0.65 0.64 0.65 0.59 0.60 0.60 0.60 0.54 0.55 0.55 0.55 0.50 0.50 0.51 0.50 0.45 0.45 0.46 0.45 0.41 0.40 0.42 0.40 0.36 0.35 0.37 0.35 0.32 0.30 0.33 0.30 0.27 0.25 0.28 0.25 0.23 0.20 0.24 0.20 0.18 0.15 0.19 0.15 0.14 0.10 0.15 0.10 0.09 0.05 0.10 0.05 0.05 ADMD060EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS Curtain Wall System BLANK PAGE ADMD060EN kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 42 EC 97911-099 JULY, 2016
Similar documents
Trifab VG 451/451T
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH and WITHOUT HORIZONTALS and ...
More information1600 SS - Kawneer
1600 SS can be supplied fabricated and KD or in stock lengths Interlocking mullion design eliminates need for anti-buckling clips Concealed fastener joinery creates smooth, monolithic appearance EP...
More information1620 Curtain Wall System
modified to expand design flexibility. Please contact your Kawneer representative for further assistance.
More information