1600 SS - Kawneer

Transcription

1600 SS - Kawneer
1600 SS
DECEMBER, 2013
EC 97911-053
FEATURES
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1600 SS has 2-1/2" (63.5) sight lines
Standard 6" (152.4) or 7-1/2" (190.5) depth systems
Infill options up to 1-1/8" (28.6)
A pre-glazed option, 1600 SS (Preglazed), is also available
Perimeter seal can be installed at the pressure plate or mullion shoulder
1600 SS can be supplied fabricated and KD or in stock lengths
Interlocking mullion design eliminates need for anti-buckling clips
Concealed fastener joinery creates smooth, monolithic appearance
EPDM gaskets and thermal break
Screw spline joinery method allows shop assembly of ladder sections, reducing field labor
Corners available with shear block fabrication method
Offers integrated entrance framing systems
Silicone compatible glazing materials for long-lasting seals
Two color option
PermanodicTM anodized finishes in seven choices
Painted finishes in standard and custom choices
Optional Features
•
•
•
•
•
•
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
• 1600 SS is an outside glazed captured or SSG curtain wall system
Captured system thermal separator can be pre-installed into pressure plate
Captured and SSG systems integrate with concealed GLASSventTM for curtain wall
Captured system Integrates with standard Kawneer windows
Deep and bullnose covers available
Integrates with VersoleilTM Sunshade Outrigger System and Horizontal or Vertical Single
Blade System
Profit$MakerTM plus die sets available
Product Applications
• Ideal for low to mid-rise applications where high performance is desired
• Most of the product assembly can be done in the shop rather than the field.
This allows for better quality control and reduces expensive field labor.
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADMD060
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 SS
DECEMBER, 2013
BLANK PAGE
EC 97911-053
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
1600 SS
DECEMBER, 2013
EC 97911-053
3
INDEX
PICTORIAL VIEW................................................................................ 5
FRAMING DETAILS.......................................................................... 6,7
ENTRANCE DETAILS...................................................................... 8,9
1600 SS (PREGLAZED) FRAMING DETAILS.................................. 10
FRAMING DETAILS (RTS)........................................................... 11,12
ENTRANCE DETAILS (RTS)............................................................. 13
CORNER DETAILS....................................................................... 14,15
GLASSventTM FOR CURTAIN WALL / WINDOWS............................ 16
BACK PAN DETAILS......................................................................... 17
ANCHORING................................................................................ 18,19
WIND LOAD / DEAD LOAD CHARTS.......................................... 20-25
THERMAL CHARTS .................................................................... 26-33
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED
ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT
CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR
GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded
and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be
modified to expand design flexibility. Please contact your Kawneer representative for further assistance.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses
( ) are millimeters unless otherwise noted.
The following metric (SI ) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
Kawneer reserves the right to change configurations without prior notice when deemed necessary for product
improvement.
kawneer.com
ADMD060
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 SS
DECEMBER, 2013
BLANK PAGE
EC 97911-053
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
kawneer.com
1600 SS
EC 97911-053
PICTORIAL VIEW
ADMD060
5
FRAMING DETAILS
7
ENTRANCE
DETAILS
1
HEAD
6"
(152.4)
7-1/2"
(190.5)
1
1A
2
HORIZONTAL
2
6
8
9
ANCHOR
DETAILS
4
5
5A
ELEVATION IS NUMBER KEYED TO DETAILS
CAPTURED MULLION ELEVATION
4
HORIZONTAL
5A
SILL
5
SILL
PERIMETER
PRESSURE PLATE
PERIMETER MULLION
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
1600 SS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1/2"
(12.7)
PERIMETER
PRESSURE PLATE
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1A
HEAD
2-1/2"
(63.5)
6
DECEMBER, 2013
EC 97911-053
SCALE 3" = 1'-0"
PERIMETER MULLION
3
CORNER
DETAILS
3
HORIZONTAL
6"
(152.4)
7-1/2"
(190.5)
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
1/2"
(12.7)
kawneer.com
2-1/2"
(63.5)
7
JAMB
(1" INFILL)
1600 SS
EC 97911-053
FRAMING DETAILS
SCALE 3" = 1'-0"
1
1A
2
2A
ANCHOR
DETAILS
6, 6A
6
JAMB
(1/4" INFILL)
10
3
7, 7A
11
ENTRANCE
DETAILS
4
4A
ADMD060
CORNER
DETAILS
5
5A
ELEVATION IS NUMBER KEYED TO DETAILS
SSG MULLION ELEVATION
6A
SSG MULLION
AT JAMB (1/4")
8
CAPTURED
MULLION (1/4")
10
SSG MULLION
(1/4" INFILL)
7A
SSG MULLION
AT JAMB (1")
9
CAPTURED
MULLION (1")
11
SSG MULLION
(1" INFILL)
7
7-1/2"
(190.5)
1-3/4"
(63.5)
1/8"
(3.2)
1
7-1/2"
(190.5)
1
TRANSOM BAR
CENTER HUNG
WITH CONCEALED OVER
HEAD CLOSER
ADMD060
3
2
4
B/H or O/P
BUTT HUNG OR OFFSET PIVOT
WITH SINGLE ACTING OFFSET ARM
CONCEALED OVERHEAD CLOSER
C/H
2-1/2"
(63.5)
2-1/2"
(63.5)
B/H or O/P
ELEVATION IS NUMBER KEYED TO DETAILS
ENTRANCE ELEVATION
BUTT HUNG OR OFFSET PIVOT
WITH SURFACE CLOSER
7-1/2"
(190.5)
6"
(152.4)
BUTT HUNG
OR
OFFSET PIVOT
2
DOOR JAMB
1A
TRANSOM BAR
3/4"
(19.0)
7-1/2"
(190.5)
6"
(152.4)
CENTER HUNG
4
DOOR JAMB
3
TRANSOM BAR
3/4"
(19.0)
kawneer.com
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
2-1/2"
(63.5)
ENTRANCE DETAILS
© Kawneer Company, Inc., 2013
2-1/2"
(63.5)
7-1/2"
(190.5)
6"
(152.4)
1-3/4"
(63.5)
1/8"
(3.2)
1600 SS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2-1/2"
(63.5)
SCALE 3" = 1'-0"
6"
(152.4)
1-3/4"
(63.5)
1/8"
(3.2)
8
DECEMBER, 2013
EC 97911-053
5
6
6"
(152.4)
1600 SS
DECEMBER, 2013
EC 97911-053
9
ENTRANCE DETAILS
SCALE 3" = 1'-0"
7-1/2"
(190.5)
2-1/2"
(63.5)
6"
(152.4)
Optional
Interior Cover
2-1/2"
(63.5)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7-1/2"
(190.5)
6"
(152.4)
5
FLUSH TRANSOM BAR
5B
FLUSH TRANSOM BAR
BUTT HUNG OR OFFSET PIVOT
WITH SURFACE CLOSER
BUTT HUNG OR OFFSET PIVOT
WITH SURFACE CLOSER
7-1/2"
(190.5)
6"
(152.4)
2-1/2"
(63.5)
Optional
Interior Cover
5A
FLUSH TRANSOM BAR
6
FLUSH DOOR JAMB
BUTT HUNG OR OFFSET PIVOT
WITH LCN 2030 COC CLOSER
6"
(152.4)
2-1/2"
(63.5)
© Kawneer Company, Inc., 2013
ALTERNATE SSG
FLUSH DOOR JAMB
ALTERNATE
SSG DOOR JAMB
2-1/2"
(63.5)
2-1/2"
(63.5)
kawneer.com
BUTT HUNG
OR
OFFSET PIVOT
6"
(152.4)
7-1/2"
(190.5)
BUTT HUNG
OR
OFFSET PIVOT
6"
(152.4)
7-1/2"
(190.5)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
7-1/2"
(190.5)
BUTT HUNG
OR
OFFSET PIVOT
ADMD060
3/4"
(19.0)
PRE-GLAZED
EXPANSION
HORIZONTAL
1" OVER 1"
3"
(76.2)
1600 SS FRAMING DETAILS
7
1
HEAD
6"
(152.4)
1
1A
6
7-1/2"
(190.5)
2A
2
2A
PRE-GLAZED
EXPANSION
HORIZONTAL
1" OVER 1/4"
8
3
4 9
4A
5
5A
UNIT WALL ELEVATION
ELEVATION IS NUMBER KEYED TO DETAILS
3
HORIZONTAL
4A
4
HORIZONTAL
5A
SILL
5
SILL
PERIMETER
PRESSURE PLATE
PERIMETER MULLION
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
1600 SS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1/2"
(12.7)
PERIMETER
PRESSURE PLATE
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1A
HEAD
2-1/2"
(63.5)
SCALE 3" = 1'-0"
3"
(76.2)
10
DECEMBER, 2013
EC 97911-053
NOTE: SEE PAGE 7 FOR VERTICAL MULLION DETAILS
PERIMETER MULLION
2
HORIZONTAL
1600 SS
DECEMBER, 2013
EC 97911-053
FRAMING DETAILS (RTS)
(RTS) - Reversed Thermal Separator
SCALE 3" = 1'-0"
PERIMETER MULLION
6"
(152.4)
7-1/2"
(190.5)
1
1A
2A
PRE-GLAZED
EXPANSION
HORIZONTAL
1" OVER 1/4"
2
ANCHOR
DETAILS
6
8
3
7
CORNER
DETAILS
9
2
HORIZONTAL
4
ENTRANCE
DETAILS
5
5A
3
HORIZONTAL
(RTS) CAPTURED MULLION ELEVATION
ELEVATION IS NUMBER KEYED TO DETAILS
3"
(76.2)
4A
PRE-GLAZED
EXPANSION
HORIZONTAL
1" OVER 1"
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2-1/2"
(63.5)
1
HEAD
1A
HEAD
3"
(76.2)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1/2"
(12.7)
PERIMETER
PRESSURE PLATE
4
HORIZONTAL
5A
SILL
5
SILL
PERIMETER MULLION
PERIMETER
PRESSURE PLATE
kawneer.com
ADMD060
11
SCALE 3" = 1'-0"
6
JAMB
(1/4" INFILL)
1/2"
(12.7)
8
MULLION
2-1/2"
(63.5)
7
JAMB
(1" INFILL)
9
MULLION
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
FRAMING DETAILS (RTS)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 SS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
6"
(152.4)
7-1/2"
(190.5)
12
DECEMBER, 2013
EC 97911-053
(RTS) - Reversed Thermal Separator
1600 SS
DECEMBER, 2013
EC 97911-053
ENTRANCE DETAILS (RTS)
SCALE 3" = 1'-0"
(RTS) - Reversed Thermal Separator
1
1-3/4"
(63.5)
1/8"
(3.2)
2-1/2"
(63.5)
4
C/H
B/H or O/P
1
TRANSOM BAR
(RTS) ENTRANCE ELEVATION
ELEVATION IS NUMBER KEYED TO DETAILS
BUTT HUNG OR OFFSET PIVOT
WITH SURFACE CLOSER
7-1/2"
(190.5)
6"
(152.4)
2
DOOR JAMB
7-1/2"
(190.5)
1-3/4"
(63.5)
1/8"
(3.2)
6"
(152.4)
BUTT HUNG
OR
OFFSET PIVOT
1A
TRANSOM BAR
2-1/2"
(63.5)
BUTT HUNG OR OFFSET PIVOT
WITH SINGLE ACTING OFFSET ARM
CONCEALED OVERHEAD CLOSER
3/4"
(19.0)
7-1/2"
(190.5)
6"
(152.4)
4
DOOR JAMB
3
TRANSOM BAR
2-1/2"
(63.5)
CENTER HUNG
WITH CONCEALED OVER
HEAD CLOSER
kawneer.com
6"
(152.4)
1-3/4"
(63.5)
7-1/2"
(190.5)
2-1/2"
(63.5)
CENTER HUNG
1/8"
(3.2)
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3
2
2-1/2"
(63.5)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
7-1/2"
(190.5)
6"
(152.4)
ADMD060
3/4"
(19.0)
13
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 SS
CORNER DETAILS
90° OUTSIDE CORNER
90° INSIDE CORNER
90° OUTSIDE CORNER (RTS)
90° INSIDE CORNER (RTS)
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
14
DECEMBER, 2013
EC 97911-053
SCALE 3" = 1'-0"
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
kawneer.com
1600 SS
EC 97911-053
CORNER DETAILS
SCALE 3" = 1'-0"
90° OUTSIDE CORNER
135° OUTSIDE CORNER
90° OUTSIDE SSG CORNER
90° INSIDE SSG CORNER
135° OUTSIDE SSG CORNER
135° INSIDE SSG CORNER
ADMD060
15
GLASSvent
FOR CURTAIN WALL / WINDOWS
HEAD
SILL
JAMB
AT CAPTURED MULLION
ADMD060
JAMB
AT SSG MULLION
HEAD
SILL
JAMB
kawneer.com
© Kawneer Company, Inc., 2013
1600 SS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
TM
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
16
DECEMBER, 2013
EC 97911-053
SCALE 3" = 1'-0"
GLASSventTM FOR CURTAIN WALL
8225TL IsoLockTM WINDOWS
NOTE: Other vent types can be accommodated. Contact your
Kawneer representative for other options.
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
kawneer.com
2
ELEVATION IS NUMBER KEYED TO DETAILS
1
2
JAMB MULLION
AT SPANDREL
MULLION AT SPANDREL
3/4"
(19.1)
3"
(76.2)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
1600 SS
EC 97911-053
BACKPAN DETAILS
SCALE 3" = 1'-0"
3
4
5
HEAD
3
6
NOTE: 7-1/2" SYSTEM SHOWN, 6" SYSTEM SIMILAR
EXPANSION JOINT
4
TYPICAL DEADLOAD ANCHOR
5
2-1/2"
(63.5)
TRANSOM – SPANDREL OVER VISION
6
ADMD060
17
1" (25.4) MINIMUM
ANCHORING TO SUPPORT STEEL
ADMD060
1" (25.4) MINIMUM
ANCHORING TO FLOOR SLAB
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 SS
DECEMBER, 2013
ANCHORING
EC 97911-053
kawneer.com
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
18
Actual project conditions will determine specific anchor design. Details on this page are for reference only.
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
1600 SS
EC 97911-053
ANCHORING
Actual project conditions will determine specific anchor design. Details on this page are for reference only.
1" (25.4) MINIMUM
ANCHORING TO HORIZONTAL
STRUCTURAL STEEL
1" (25.4) MINIMUM
ANCHORING TO VERTICAL
STRUCTURAL STEEL
kawneer.com
ADMD060
19
20
1600 SS
DECEMBER, 2013
EC 97911-053
WIND LOAD / DEAD LOAD CHARTS
DEAD LOAD CHARTS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate
horizontal member. The accompanying charts are calculated for 1" (25) thick insulating glass or 1/4" (6) thick glass supported
on two setting blocks placed at the loading points shown.
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4"
above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress
and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted
curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures
of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A
4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these
curves, contact your Kawneer representative for additional information.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
WIND LOAD CHARTS
1600 SS
DECEMBER, 2013
EC 97911-053
WIND LOAD CHARTS (1" INFILL)
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
MULLION CENTERS IN METERS
1.0
2.0
28
12
11
A
10
3.0
9
B
8
C
D
2.0
E
7
6
24
23
7.0
A
22
21
20
6.0
19
B
18
17
5.0
C
15
5
D
14
4
1.0
169001
0
1
2
3
4
5
6
7
4.0
13
8
169002
12
I = 5.652 (235.25 x 104)
S = 1.954 (32.02 x 103)
E
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
SINGLE SPAN
TWIN SPAN
MULLION CENTERS IN METERS
MULLION CENTERS IN METERS
1.0
2.0
20
18
28
4.0
13
A
12
B
11
C
10
3.0
9
D
E
8
7
2.0
6
9.0
A
27
8.0
26
MULLION HEIGHT IN FEET
14
2.0
25
EQUAL
15
MULLION HEIGHT IN METERS
5.0
MULLION HEIGHT
17
EQUAL
29
MULLION HEIGHT
19
16
1.0
30
6.0
24
B
23
7.0
22
21
C
20
6.0
19
18
D
17
5.0
16
E
15
5
14
4
1.0
3
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
kawneer.com
4.0
13
169003
169004
I = 11.512 (479.16 x 104)
S = 3.141 (51.47 x 103)
ADMD060
12
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
MULLION HEIGHT IN METERS
3
MULLION HEIGHT IN FEET
8.0
26
16
MULLION CENTERS IN FEET
© Kawneer Company, Inc., 2013
9.0
27
MULLION HEIGHT IN FEET
4.0
13
2.0
25
EQUAL
14
MULLION HEIGHT
15
MULLION HEIGHT IN METERS
5.0
EQUAL
18
MULLION HEIGHTT
29
16
1.0
30
19
2
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
MULLION CENTERS IN METERS
6.0
17
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
20
TWIN SPAN
MULLION HEIGHT IN METERS
SINGLE SPAN
2
21
1600 SS
DECEMBER, 2013
WIND LOAD CHARTS (1" INFILL)
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
18
28
13
12
11
10
3.0
9
E
8
D C
7
A
B
24
23
7.0
22
A
21
B
E
20
6.0
C
19
D
18
17
5.0
16
15
14
4
1.0
2
0
1
2
3
4
5
6
7
4.0
13
169005
8
12
169006
I = 3.609 (150.22 x 104)
S = 1.773 (29.05 x 103)
MULLION CENTERS IN FEET
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
SINGLE SPAN
TWIN SPAN
MULLION CENTERS IN METERS
MULLION CENTERS IN METERS
2.0
1.0
20
18
28
4.0
13
12
A
E
11
B
D C
10
3.0
9
8
7
2.0
6
27
A
8.0
26
MULLION HEIGHT IN FEET
14
2.0
9.0
E
25
EQUAL
15
MULLION HEIGHT IN METERS
5.0
MULLION HEIGHT
17
EQUAL
29
MULLION HEIGHT
19
16
1.0
30
6.0
B
D C
24
23
7.0
22
21
20
6.0
19
18
17
MULLION HEIGHT IN METERS
3
MULLION HEIGHT IN FEET
8.0
25
5
5.0
16
15
5
14
4
1.0
3
2
9.0
26
2.0
6
2.0
27
MULLION HEIGHT IN FEET
4.0
MULLION HEIGHT
14
MULLION HEIGHT IN METERS
5.0
EQUAL
17
EQUAL
29
MULLION HEIGHT
19
15
1.0
30
6.0
16
MULLION HEIGHT IN FEET
MULLION CENTERS IN METERS
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
4.0
13
169007
169008
I = 8.065 (335.69 x 104)
S = 2.842 (46.57 x 103)
ADMD060
12
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
kawneer.com
© Kawneer Company, Inc., 2013
20
2.0
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
MULLION CENTERS IN METERS
TWIN SPAN
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
SINGLE SPAN
1.0
EC 97911-053
MULLION HEIGHT IN METERS
22
GLASS HEIGHT IN FEET
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0
0
kawneer.com
1
1
2
2
3
3
(1/4" INFILL)
SPAN IN METERS
13
4
4
5
5
6
1.0
6
7
7
A = 1/4 POINT LOADING
B = 1/8 POINT LOADING
11
10
9
3.0
8
6
7
A
2.0
5
4
3
1.0
2
1
SPAN IN METERS
2.0
10
9
3.0
8
A
7
6
2.0
5
4
3
1.0
2
169017
I = 2.052 (85.41 x 104)
S = 1.642 (26.91 x 103)
1
8
SPAN IN FEET
ADMD060
1.0
B
169014
I = 1.620 (67.43 x 104)
S = 1.296 (21.24 x 103)
0
10
9
8
0
13
13
12
12
11
11
0
3.0
8
7
6
B
2.0
5
4
3
A
1.0
SPAN IN FEET
0
0
1
(1/4" INFILL)
A = 1/4 POINT LOADING
B = 1/8 POINT LOADING
1
2
2
3
3
4
4
5
5
6
1.0
SPAN IN FEET
6
7
10
9
3.0
8
7
B
6
2.0
5
4
3
A
1.0
2
1
7
8
GLASS HEIGHT IN METERS
1600 SS
GLASS HEIGHT IN METERS
0
2.0
GLASS HEIGHT IN FEET
EC 97911-053
GLASS HEIGHT IN FEET
12
GLASS HEIGHT IN METERS
1.0
GLASS HEIGHT IN METERS
GLASS HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
23
DEAD LOAD CHARTS
(1" INFILL)
SPAN IN METERS
13
2.0
11
12
2
1
SPAN IN FEET
8
SPAN IN METERS
(1" INFILL)
2.0
GLASS HEIGHT IN FEET
0
1
1
2
2
3
3
4
4
5
5
6
1.0
6
7
7
A = 1/4 POINT LOADING
B = 1/8 POINT LOADING
3.0
9
8
7
6
2.0
5
4
B
3
1.0
2
A
1
SPAN IN METERS
2.0
10
3.0
9
8
7
6
2.0
5
4
B
3
1.0
2
2
B
1
1
A
0
0
A
169019
I = 0.598 (24.89 x 104)
S = 0.470 (7.70 x 103)
SPAN IN FEET
8
ADMD060
1.0
12
12
11
11
169016
I = 0.589 (24.52 x 104)
S = 0.456 (7.47 x 103)
0
10
9
8
13
13
12
12
11
11
3.0
8
7
6
2.0
5
4
3
1.0
2
B
1
0
A
SPAN IN FEET
0
0
1
(1/4" INFILL)
A = 1/4 POINT LOADING
B = 1/8 POINT LOADING
1
2
SPAN IN FEET
2
3
3
4
4
5
5
6
1.0
6
7
7
8
SPAN IN METERS
2.0
10
9
3.0
8
7
6
2.0
5
4
3
1.0
SPAN IN FEET
8
kawneer.com
© Kawneer Company, Inc., 2013
SPAN IN METERS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
(1/4" INFILL)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
DEAD LOAD CHARTS
GLASS HEIGHT IN METERS
13
GLASS HEIGHT IN FEET
1600 SS
GLASS HEIGHT IN METERS
0
2.0
GLASS HEIGHT IN FEET
10
GLASS HEIGHT IN METERS
1.0
GLASS HEIGHT IN METERS
GLASS HEIGHT IN FEET
24
DECEMBER, 2013
EC 97911-053
(1" INFILL)
SPAN IN METERS
13
2.0
(1" INFILL)
GLASS HEIGHT IN FEET
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0
kawneer.com
1
1
2
2
3
3
(1/4" INFILL)
SPAN IN METERS
13
4
4
5
5
6
1.0
6
7
7
A = 1/4 POINT LOADING
B = 1/8 POINT LOADING
9
3.0
8
7
6
2.0
5
4
B
3
1.0
2
A
1
SPAN IN METERS
2.0
10
9
3.0
8
7
6
2.0
5
4
B
3
1.0
2
A
169018
I = 0.671 (27.93 x 104)
S = 0.514 (8.42 x 103)
1
0
8
SPAN IN FEET
ADMD060
1.0
12
12
11
11
0
10
9
8
13
13
12
12
11
11
3.0
8
7
6
2.0
5
4
169015
3
I = 0.659 (27.43 x 104)
S = 0.496 (8.13 x 103)
2
B
1
A
1.0
SPAN IN FEET
0
0
1
(1/4" INFILL)
A = 1/4 POINT LOADING
B = 1/8 POINT LOADING
1
2
2
3
3
4
4
5
5
6
1.0
SPAN IN FEET
6
7
10
9
3.0
8
7
6
2.0
5
4
3
2
B
1.0
1
A
0
7
8
GLASS HEIGHT IN METERS
1600 SS
GLASS HEIGHT IN METERS
0
2.0
GLASS HEIGHT IN FEET
EC 97911-053
GLASS HEIGHT IN FEET
10
GLASS HEIGHT IN METERS
1.0
GLASS HEIGHT IN METERS
GLASS HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2013
25
DEAD LOAD CHARTS
(1" INFILL)
SPAN IN METERS
13
2.0
0
SPAN IN FEET
8
SPAN IN METERS
(1" INFILL)
2.0
1600 SS
26
DECEMBER, 2013
THERMAL CHARTS
EC 97911-053
Project Specific U-factor
Example Calculation
(Based on single bay of Curtain Wall/Window Wall)
6'-0"
D.L.O.
SPANDREL
9'-0"
D.L.O.
VISION
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
5'-0"
D.L.O.
Vision Area
Example Glass U-factor
= 0.48 Btu/(ft2 · h · °F)
Vision Area
= 5(9 + 8 + 4) = 105.0 ft2
Total Area (Vision)
= 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2
Percentage of Vision Glass
= (Vision Area ÷ Total Area)100
= (105.0 ÷ 113.2)100 = 93%
Spandrel Area
Example Spandrel R-value
= 15 (ft2 · h · °F)/Btu
Spandrel Area
= 5(6 + 3) = 45.0 ft2
Total Area (Spandrel)
= 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2
Percent of Spandrel
= (Spandrel Area ÷ Total Area)100
= (49.0 ÷ 49.6)100 = 91%
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
VISION
2-1/2" Typ.
3'-0"
D.L.O.
4'-0"
D.L.O.
VISION
31'-3"
SPANDREL
8'-0"
D.L.O.
2-1/2" Typ.
1600 SS
DECEMBER, 2013
EC 97911-053
27
THERMAL CHARTS
Vision Area Chart
System U-factor vs Percent of Vision Area
(N
0.70
E IGN
PL S
M E
A D
EX OR
F
T
O
COG
U-factor
0.53
0.50
0.40
0.30
)
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.60
Btu
h·ft 2·°F
System U-factor
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
0.80
93%
0.20
95
85
90
75
80
70
Vision Area / Total Area (%)
Based on a single curtain wall bay of 93% vision glass and center
of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F)
System U-factor vs Percent of Spandrel Area
Spandrel
R-value
E IGN
PL S
M E
A D
EX OR
F
T
O
3.00
4.00
© Kawneer Company, Inc., 2013
5.00
0.30
0.21
0.20
0.10
91%
95
0.40
)
11.00
15.00
19.00
30.00
0.50
Btu
h·ft 2·°F
System U-factor
2.00
0.60
(N
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Spandrel Area Chart
90
85
80
75
70
Spandrel Area / Total Area (%)
Based on a single curtain wall bay of 91% spandrel and center of
spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F)
kawneer.com
ADMD060
1600 SS
DECEMBER, 2013
THERMAL CHARTS (CAPTURED)
EC 97911-053
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
System U-Factor for Vision Glass
0.90
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
(5.00)
0.85
0.80
(4.50)
0.75
0.70
(4.00)
System U-Factor
0.45
System U-Factor
0.50
2
0.55
(2.73)
(2.61)
(2.50)
(2.39)
(2.27)
(2.16)
(2.05)
(1.93)
(1.82)
(1.71)
(1.59)
(1.48)
(1.37)
(1.25)
(1.14)
( m W·°C )
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
(3.50)
( m W·°C )
0.60
COG
U-factor
Btu
h·ft 2·°F
0.65
(3.00)
(2.50)
0.40
0.35
(2.00)
0.30
(1.50)
0.25
0.20
95
90
85
80
75
70
0.70
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System U-Factors for Spandrel Glass
(4.00)
0.65
0.60
(3.50)
0.55
(3.00)
0.45
2.00 (0.35)
0.40
3.00 (0.53)
0.35
4.00 (0.70)
0.30
5.00 (0.88)
0.25
(2.50)
2
0.50
Spandrel
R-Value
(2.00)
(1.50)
0.20
(2.00)
11.00 (1.94)
0.15
15.00 (2.64)
0.10
19.00 (3.34)
(1.50)
30.00 (5.28)
0.05
95
90
85
80
75
70
Spandrel Area / Total Area (%)
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
Vision Area / Total Area (%)
Btu
h·ft 2·°F
28
1600 SS
DECEMBER, 2013
EC 97911-053
THERMAL CHARTS (CAPTURED)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
0.90
0.90
0.85
0.85
0.80
0.80
0.75
0.75
0.70
0.70
0.65
0.65
0.60
0.60
0.55
0.55
0.50
0.50
0.45
0.45
0.40
0.40
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
29
0.35
0.35
0.30
0.30
0.25
0.25
0.20
0.20
0.15
0.10
95
90
80
85
75
70
Vision Area / Total Area (%)
Charts are generated per AAMA 507.
0.90
0.90
0.85
0.85
0.80
0.80
0.75
0.75
0.70
0.70
0.65
0.65
0.55
0.55
0.50
0.50
0.45
0.45
0.40
0.40
0.35
0.35
0.30
0.30
0.25
0.25
0.20
0.20
0.15
0.10
95
90
80
85
Vision Ares / Total Area (%)
Charts are generated per AAMA 507.
kawneer.com
ADMD060
75
70
System VT
0.60
0.60
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
1600 SS
DECEMBER, 2013
THERMAL PERFORMANCE MATRIX (NFRC SIZE) - (CAPTURED)
EC 97911-053
Glass U-Factor 3
Overall U-Factor 4
0.48
0.62
0.46
0.60
0.44
0.59
0.42
0.57
0.40
0.55
0.38
0.54
0.36
0.52
0.34
0.50
0.32
0.49
0.30
0.47
0.28
0.46
0.26
0.44
0.24
0.42
0.22
0.41
0.20
0.39
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.90
0.82
0.90
0.81
0.85
0.78
0.85
0.76
0.80
0.73
0.80
0.72
0.75
0.69
0.75
0.67
0.70
0.64
0.70
0.63
0.65
0.60
0.65
0.58
0.60
0.55
0.60
0.54
0.55
0.51
0.55
0.49
0.50
0.46
0.50
0.45
0.45
0.42
0.45
0.40
0.40
0.37
0.40
0.36
0.35
0.33
0.35
0.31
0.30
0.29
0.30
0.27
0.25
0.24
0.25
0.22
0.20
0.20
0.20
0.18
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.
2. SHGC and VT values are determined in accordance with NFRC 200.
3. Glass properties are based on center of glass values and are obtained from your glass supplier.
4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of
2000mm wide by 2000mm high (78-3/4" by 78-3/4").
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
SHGC Matrix 2
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
30
1600 SS
DECEMBER, 2013
EC 97911-053
31
THERMAL CHARTS (SSG)
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
System U-Factor for Vision Glass
0.90
(5.00)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
0.85
0.80
(4.50)
0.75
0.70
(4.00)
0.45
2
System U-Factor
0.50
System U-Factor
(2.73)
(2.61)
(2.50)
(2.39)
(2.27)
(2.16)
(2.05)
(1.93)
(1.82)
(1.71)
(1.59)
(1.48)
(1.37)
(1.25)
(1.14)
( m W·°C )
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.55
(3.50)
( m W·°C )
0.60
COG
U-factor
Btu
h·ft 2·°F
0.65
(3.00)
(2.50)
0.40
0.35
(2.00)
0.30
(1.50)
0.25
0.20
95
90
85
80
75
70
System U-Factors for Spandrel Glass
0.70
(4.00)
0.65
0.60
(3.50)
0.55
(3.00)
2.00 (0.35)
0.40
0.35
3.00 (0.53)
Btu
h·ft 2·°F
0.45
(2.50)
2
0.50
Spandrel
R-Value
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Vision Area / Total Area (%)
(2.00)
0.30
4.00 (0.70)
0.25
5.00 (0.88)
(1.50)
0.20
(2.00)
11.00 (1.94)
0.15
15.00 (2.64)
19.00 (3.34)
0.10
30.00 (5.28)
95
0.05
90
85
80
Spandrel Area / Total Area (%)
kawneer.com
ADMD060
75
70
(1.50)
1600 SS
DECEMBER, 2013
THERMAL CHARTS (SSG)
EC 97911-053
0.90
0.85
0.85
0.80
0.80
0.75
0.75
0.70
0.70
0.65
0.65
0.60
0.60
0.55
0.55
0.50
0.50
0.45
0.45
0.40
0.40
0.35
0.35
0.30
0.30
0.25
0.25
0.20
0.20
System SHGC
0.90
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
0.15
0.10
95
90
80
85
75
70
Vision Area / Total Area (%)
Charts are generated per AAMA 507.
0.90
0.85
0.85
0.80
0.80
0.75
0.75
0.70
0.70
0.65
0.65
0.60
0.60
0.55
0.55
0.50
0.50
0.45
0.45
0.40
0.40
0.35
0.35
0.30
0.30
0.25
0.25
0.20
0.20
0.15
0.10
95
90
80
85
75
70
Vision Ares / Total Area (%)
Charts are generated per AAMA 507.
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
0.90
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
System VT
32
1600 SS
DECEMBER, 2013
EC 97911-053
THERMAL PERFORMANCE MATRIX (NFRC SIZE) - (SSG)
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.56
0.46
0.54
0.44
0.53
0.42
0.51
0.40
0.49
0.38
0.48
0.36
0.46
0.34
0.44
0.32
0.42
0.30
0.41
0.28
0.39
0.26
0.37
0.24
0.36
0.22
0.34
0.20
0.32
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
SHGC Matrix 2
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.90
0.87
0.90
0.81
0.85
0.82
0.85
0.77
0.80
0.77
0.80
0.72
0.75
0.73
0.75
0.68
0.70
0.68
0.70
0.63
0.65
0.64
0.65
0.59
0.60
0.59
0.60
0.54
0.55
0.55
0.55
0.50
0.50
0.50
0.50
0.45
0.45
0.46
0.45
0.41
0.40
0.41
0.40
0.36
0.35
0.37
0.35
0.32
0.30
0.32
0.30
0.27
0.25
0.28
0.25
0.23
0.20
0.23
0.20
0.18
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.
2. SHGC and VT values are determined in accordance with NFRC 200.
3. Glass properties are based on center of glass values and are obtained from your glass supplier.
4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of
2000mm wide by 2000mm high (78-3/4" by 78-3/4").
kawneer.com
ADMD060
33
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 SS
DECEMBER, 2013
BLANK PAGE
EC 97911-053
ADMD060
kawneer.com
© Kawneer Company, Inc., 2013
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
34

Similar documents

1600 SS Curtain Wall System

1600 SS Curtain Wall System • 1600 SS can be supplied fabricated and KD or in stock lengths • Interlocking mullion design eliminates need for anti-buckling clips • Concealed fastener joinery creates smooth, monolithic appe...

More information

1620 Curtain Wall System

1620 Curtain Wall System modified to expand design flexibility. Please contact your Kawneer representative for further assistance.

More information

Trifab VG 451/451T

Trifab VG 451/451T Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH and WITHOUT HORIZONTALS and ...

More information