1600 SS DECEMBER, 2013 EC 97911-053 FEATURES Features • • • • • • • • • • • • • • • • 1600 SS has 2-1/2" (63.5) sight lines Standard 6" (152.4) or 7-1/2" (190.5) depth systems Infill options up to 1-1/8" (28.6) A pre-glazed option, 1600 SS (Preglazed), is also available Perimeter seal can be installed at the pressure plate or mullion shoulder 1600 SS can be supplied fabricated and KD or in stock lengths Interlocking mullion design eliminates need for anti-buckling clips Concealed fastener joinery creates smooth, monolithic appearance EPDM gaskets and thermal break Screw spline joinery method allows shop assembly of ladder sections, reducing field labor Corners available with shear block fabrication method Offers integrated entrance framing systems Silicone compatible glazing materials for long-lasting seals Two color option PermanodicTM anodized finishes in seven choices Painted finishes in standard and custom choices Optional Features • • • • • • © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. • 1600 SS is an outside glazed captured or SSG curtain wall system Captured system thermal separator can be pre-installed into pressure plate Captured and SSG systems integrate with concealed GLASSventTM for curtain wall Captured system Integrates with standard Kawneer windows Deep and bullnose covers available Integrates with VersoleilTM Sunshade Outrigger System and Horizontal or Vertical Single Blade System Profit$MakerTM plus die sets available Product Applications • Ideal for low to mid-rise applications where high performance is desired • Most of the product assembly can be done in the shop rather than the field. This allows for better quality control and reduces expensive field labor. For specific product applications, Consult your Kawneer representative. kawneer.com ADMD060 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS DECEMBER, 2013 BLANK PAGE EC 97911-053 ADMD060 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 1600 SS DECEMBER, 2013 EC 97911-053 3 INDEX PICTORIAL VIEW................................................................................ 5 FRAMING DETAILS.......................................................................... 6,7 ENTRANCE DETAILS...................................................................... 8,9 1600 SS (PREGLAZED) FRAMING DETAILS.................................. 10 FRAMING DETAILS (RTS)........................................................... 11,12 ENTRANCE DETAILS (RTS)............................................................. 13 CORNER DETAILS....................................................................... 14,15 GLASSventTM FOR CURTAIN WALL / WINDOWS............................ 16 BACK PAN DETAILS......................................................................... 17 ANCHORING................................................................................ 18,19 WIND LOAD / DEAD LOAD CHARTS.......................................... 20-25 THERMAL CHARTS .................................................................... 26-33 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD060 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS DECEMBER, 2013 BLANK PAGE EC 97911-053 ADMD060 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 1600 SS EC 97911-053 PICTORIAL VIEW ADMD060 5 FRAMING DETAILS 7 ENTRANCE DETAILS 1 HEAD 6" (152.4) 7-1/2" (190.5) 1 1A 2 HORIZONTAL 2 6 8 9 ANCHOR DETAILS 4 5 5A ELEVATION IS NUMBER KEYED TO DETAILS CAPTURED MULLION ELEVATION 4 HORIZONTAL 5A SILL 5 SILL PERIMETER PRESSURE PLATE PERIMETER MULLION ADMD060 kawneer.com © Kawneer Company, Inc., 2013 1600 SS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1/2" (12.7) PERIMETER PRESSURE PLATE Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1A HEAD 2-1/2" (63.5) 6 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" PERIMETER MULLION 3 CORNER DETAILS 3 HORIZONTAL 6" (152.4) 7-1/2" (190.5) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 1/2" (12.7) kawneer.com 2-1/2" (63.5) 7 JAMB (1" INFILL) 1600 SS EC 97911-053 FRAMING DETAILS SCALE 3" = 1'-0" 1 1A 2 2A ANCHOR DETAILS 6, 6A 6 JAMB (1/4" INFILL) 10 3 7, 7A 11 ENTRANCE DETAILS 4 4A ADMD060 CORNER DETAILS 5 5A ELEVATION IS NUMBER KEYED TO DETAILS SSG MULLION ELEVATION 6A SSG MULLION AT JAMB (1/4") 8 CAPTURED MULLION (1/4") 10 SSG MULLION (1/4" INFILL) 7A SSG MULLION AT JAMB (1") 9 CAPTURED MULLION (1") 11 SSG MULLION (1" INFILL) 7 7-1/2" (190.5) 1-3/4" (63.5) 1/8" (3.2) 1 7-1/2" (190.5) 1 TRANSOM BAR CENTER HUNG WITH CONCEALED OVER HEAD CLOSER ADMD060 3 2 4 B/H or O/P BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING OFFSET ARM CONCEALED OVERHEAD CLOSER C/H 2-1/2" (63.5) 2-1/2" (63.5) B/H or O/P ELEVATION IS NUMBER KEYED TO DETAILS ENTRANCE ELEVATION BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER 7-1/2" (190.5) 6" (152.4) BUTT HUNG OR OFFSET PIVOT 2 DOOR JAMB 1A TRANSOM BAR 3/4" (19.0) 7-1/2" (190.5) 6" (152.4) CENTER HUNG 4 DOOR JAMB 3 TRANSOM BAR 3/4" (19.0) kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2-1/2" (63.5) ENTRANCE DETAILS © Kawneer Company, Inc., 2013 2-1/2" (63.5) 7-1/2" (190.5) 6" (152.4) 1-3/4" (63.5) 1/8" (3.2) 1600 SS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2-1/2" (63.5) SCALE 3" = 1'-0" 6" (152.4) 1-3/4" (63.5) 1/8" (3.2) 8 DECEMBER, 2013 EC 97911-053 5 6 6" (152.4) 1600 SS DECEMBER, 2013 EC 97911-053 9 ENTRANCE DETAILS SCALE 3" = 1'-0" 7-1/2" (190.5) 2-1/2" (63.5) 6" (152.4) Optional Interior Cover 2-1/2" (63.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 7-1/2" (190.5) 6" (152.4) 5 FLUSH TRANSOM BAR 5B FLUSH TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER 7-1/2" (190.5) 6" (152.4) 2-1/2" (63.5) Optional Interior Cover 5A FLUSH TRANSOM BAR 6 FLUSH DOOR JAMB BUTT HUNG OR OFFSET PIVOT WITH LCN 2030 COC CLOSER 6" (152.4) 2-1/2" (63.5) © Kawneer Company, Inc., 2013 ALTERNATE SSG FLUSH DOOR JAMB ALTERNATE SSG DOOR JAMB 2-1/2" (63.5) 2-1/2" (63.5) kawneer.com BUTT HUNG OR OFFSET PIVOT 6" (152.4) 7-1/2" (190.5) BUTT HUNG OR OFFSET PIVOT 6" (152.4) 7-1/2" (190.5) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7-1/2" (190.5) BUTT HUNG OR OFFSET PIVOT ADMD060 3/4" (19.0) PRE-GLAZED EXPANSION HORIZONTAL 1" OVER 1" 3" (76.2) 1600 SS FRAMING DETAILS 7 1 HEAD 6" (152.4) 1 1A 6 7-1/2" (190.5) 2A 2 2A PRE-GLAZED EXPANSION HORIZONTAL 1" OVER 1/4" 8 3 4 9 4A 5 5A UNIT WALL ELEVATION ELEVATION IS NUMBER KEYED TO DETAILS 3 HORIZONTAL 4A 4 HORIZONTAL 5A SILL 5 SILL PERIMETER PRESSURE PLATE PERIMETER MULLION ADMD060 kawneer.com © Kawneer Company, Inc., 2013 1600 SS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1/2" (12.7) PERIMETER PRESSURE PLATE Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1A HEAD 2-1/2" (63.5) SCALE 3" = 1'-0" 3" (76.2) 10 DECEMBER, 2013 EC 97911-053 NOTE: SEE PAGE 7 FOR VERTICAL MULLION DETAILS PERIMETER MULLION 2 HORIZONTAL 1600 SS DECEMBER, 2013 EC 97911-053 FRAMING DETAILS (RTS) (RTS) - Reversed Thermal Separator SCALE 3" = 1'-0" PERIMETER MULLION 6" (152.4) 7-1/2" (190.5) 1 1A 2A PRE-GLAZED EXPANSION HORIZONTAL 1" OVER 1/4" 2 ANCHOR DETAILS 6 8 3 7 CORNER DETAILS 9 2 HORIZONTAL 4 ENTRANCE DETAILS 5 5A 3 HORIZONTAL (RTS) CAPTURED MULLION ELEVATION ELEVATION IS NUMBER KEYED TO DETAILS 3" (76.2) 4A PRE-GLAZED EXPANSION HORIZONTAL 1" OVER 1" © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2-1/2" (63.5) 1 HEAD 1A HEAD 3" (76.2) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1/2" (12.7) PERIMETER PRESSURE PLATE 4 HORIZONTAL 5A SILL 5 SILL PERIMETER MULLION PERIMETER PRESSURE PLATE kawneer.com ADMD060 11 SCALE 3" = 1'-0" 6 JAMB (1/4" INFILL) 1/2" (12.7) 8 MULLION 2-1/2" (63.5) 7 JAMB (1" INFILL) 9 MULLION ADMD060 kawneer.com © Kawneer Company, Inc., 2013 FRAMING DETAILS (RTS) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6" (152.4) 7-1/2" (190.5) 12 DECEMBER, 2013 EC 97911-053 (RTS) - Reversed Thermal Separator 1600 SS DECEMBER, 2013 EC 97911-053 ENTRANCE DETAILS (RTS) SCALE 3" = 1'-0" (RTS) - Reversed Thermal Separator 1 1-3/4" (63.5) 1/8" (3.2) 2-1/2" (63.5) 4 C/H B/H or O/P 1 TRANSOM BAR (RTS) ENTRANCE ELEVATION ELEVATION IS NUMBER KEYED TO DETAILS BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER 7-1/2" (190.5) 6" (152.4) 2 DOOR JAMB 7-1/2" (190.5) 1-3/4" (63.5) 1/8" (3.2) 6" (152.4) BUTT HUNG OR OFFSET PIVOT 1A TRANSOM BAR 2-1/2" (63.5) BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING OFFSET ARM CONCEALED OVERHEAD CLOSER 3/4" (19.0) 7-1/2" (190.5) 6" (152.4) 4 DOOR JAMB 3 TRANSOM BAR 2-1/2" (63.5) CENTER HUNG WITH CONCEALED OVER HEAD CLOSER kawneer.com 6" (152.4) 1-3/4" (63.5) 7-1/2" (190.5) 2-1/2" (63.5) CENTER HUNG 1/8" (3.2) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 2 2-1/2" (63.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 7-1/2" (190.5) 6" (152.4) ADMD060 3/4" (19.0) 13 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS CORNER DETAILS 90° OUTSIDE CORNER 90° INSIDE CORNER 90° OUTSIDE CORNER (RTS) 90° INSIDE CORNER (RTS) ADMD060 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 1600 SS EC 97911-053 CORNER DETAILS SCALE 3" = 1'-0" 90° OUTSIDE CORNER 135° OUTSIDE CORNER 90° OUTSIDE SSG CORNER 90° INSIDE SSG CORNER 135° OUTSIDE SSG CORNER 135° INSIDE SSG CORNER ADMD060 15 GLASSvent FOR CURTAIN WALL / WINDOWS HEAD SILL JAMB AT CAPTURED MULLION ADMD060 JAMB AT SSG MULLION HEAD SILL JAMB kawneer.com © Kawneer Company, Inc., 2013 1600 SS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TM Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 16 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" GLASSventTM FOR CURTAIN WALL 8225TL IsoLockTM WINDOWS NOTE: Other vent types can be accommodated. Contact your Kawneer representative for other options. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 kawneer.com 2 ELEVATION IS NUMBER KEYED TO DETAILS 1 2 JAMB MULLION AT SPANDREL MULLION AT SPANDREL 3/4" (19.1) 3" (76.2) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 1600 SS EC 97911-053 BACKPAN DETAILS SCALE 3" = 1'-0" 3 4 5 HEAD 3 6 NOTE: 7-1/2" SYSTEM SHOWN, 6" SYSTEM SIMILAR EXPANSION JOINT 4 TYPICAL DEADLOAD ANCHOR 5 2-1/2" (63.5) TRANSOM – SPANDREL OVER VISION 6 ADMD060 17 1" (25.4) MINIMUM ANCHORING TO SUPPORT STEEL ADMD060 1" (25.4) MINIMUM ANCHORING TO FLOOR SLAB Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS DECEMBER, 2013 ANCHORING EC 97911-053 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 Actual project conditions will determine specific anchor design. Details on this page are for reference only. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 1600 SS EC 97911-053 ANCHORING Actual project conditions will determine specific anchor design. Details on this page are for reference only. 1" (25.4) MINIMUM ANCHORING TO HORIZONTAL STRUCTURAL STEEL 1" (25.4) MINIMUM ANCHORING TO VERTICAL STRUCTURAL STEEL kawneer.com ADMD060 19 20 1600 SS DECEMBER, 2013 EC 97911-053 WIND LOAD / DEAD LOAD CHARTS DEAD LOAD CHARTS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25) thick insulating glass or 1/4" (6) thick glass supported on two setting blocks placed at the loading points shown. ADMD060 kawneer.com © Kawneer Company, Inc., 2013 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS 1600 SS DECEMBER, 2013 EC 97911-053 WIND LOAD CHARTS (1" INFILL) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) MULLION CENTERS IN METERS 1.0 2.0 28 12 11 A 10 3.0 9 B 8 C D 2.0 E 7 6 24 23 7.0 A 22 21 20 6.0 19 B 18 17 5.0 C 15 5 D 14 4 1.0 169001 0 1 2 3 4 5 6 7 4.0 13 8 169002 12 I = 5.652 (235.25 x 104) S = 1.954 (32.02 x 103) E 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 2.0 20 18 28 4.0 13 A 12 B 11 C 10 3.0 9 D E 8 7 2.0 6 9.0 A 27 8.0 26 MULLION HEIGHT IN FEET 14 2.0 25 EQUAL 15 MULLION HEIGHT IN METERS 5.0 MULLION HEIGHT 17 EQUAL 29 MULLION HEIGHT 19 16 1.0 30 6.0 24 B 23 7.0 22 21 C 20 6.0 19 18 D 17 5.0 16 E 15 5 14 4 1.0 3 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com 4.0 13 169003 169004 I = 11.512 (479.16 x 104) S = 3.141 (51.47 x 103) ADMD060 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION HEIGHT IN METERS 3 MULLION HEIGHT IN FEET 8.0 26 16 MULLION CENTERS IN FEET © Kawneer Company, Inc., 2013 9.0 27 MULLION HEIGHT IN FEET 4.0 13 2.0 25 EQUAL 14 MULLION HEIGHT 15 MULLION HEIGHT IN METERS 5.0 EQUAL 18 MULLION HEIGHTT 29 16 1.0 30 19 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION CENTERS IN METERS 6.0 17 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 20 TWIN SPAN MULLION HEIGHT IN METERS SINGLE SPAN 2 21 1600 SS DECEMBER, 2013 WIND LOAD CHARTS (1" INFILL) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) 18 28 13 12 11 10 3.0 9 E 8 D C 7 A B 24 23 7.0 22 A 21 B E 20 6.0 C 19 D 18 17 5.0 16 15 14 4 1.0 2 0 1 2 3 4 5 6 7 4.0 13 169005 8 12 169006 I = 3.609 (150.22 x 104) S = 1.773 (29.05 x 103) MULLION CENTERS IN FEET 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN MULLION CENTERS IN METERS MULLION CENTERS IN METERS 2.0 1.0 20 18 28 4.0 13 12 A E 11 B D C 10 3.0 9 8 7 2.0 6 27 A 8.0 26 MULLION HEIGHT IN FEET 14 2.0 9.0 E 25 EQUAL 15 MULLION HEIGHT IN METERS 5.0 MULLION HEIGHT 17 EQUAL 29 MULLION HEIGHT 19 16 1.0 30 6.0 B D C 24 23 7.0 22 21 20 6.0 19 18 17 MULLION HEIGHT IN METERS 3 MULLION HEIGHT IN FEET 8.0 25 5 5.0 16 15 5 14 4 1.0 3 2 9.0 26 2.0 6 2.0 27 MULLION HEIGHT IN FEET 4.0 MULLION HEIGHT 14 MULLION HEIGHT IN METERS 5.0 EQUAL 17 EQUAL 29 MULLION HEIGHT 19 15 1.0 30 6.0 16 MULLION HEIGHT IN FEET MULLION CENTERS IN METERS 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET 4.0 13 169007 169008 I = 8.065 (335.69 x 104) S = 2.842 (46.57 x 103) ADMD060 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com © Kawneer Company, Inc., 2013 20 2.0 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. MULLION CENTERS IN METERS TWIN SPAN Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SINGLE SPAN 1.0 EC 97911-053 MULLION HEIGHT IN METERS 22 GLASS HEIGHT IN FEET © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0 0 kawneer.com 1 1 2 2 3 3 (1/4" INFILL) SPAN IN METERS 13 4 4 5 5 6 1.0 6 7 7 A = 1/4 POINT LOADING B = 1/8 POINT LOADING 11 10 9 3.0 8 6 7 A 2.0 5 4 3 1.0 2 1 SPAN IN METERS 2.0 10 9 3.0 8 A 7 6 2.0 5 4 3 1.0 2 169017 I = 2.052 (85.41 x 104) S = 1.642 (26.91 x 103) 1 8 SPAN IN FEET ADMD060 1.0 B 169014 I = 1.620 (67.43 x 104) S = 1.296 (21.24 x 103) 0 10 9 8 0 13 13 12 12 11 11 0 3.0 8 7 6 B 2.0 5 4 3 A 1.0 SPAN IN FEET 0 0 1 (1/4" INFILL) A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1 2 2 3 3 4 4 5 5 6 1.0 SPAN IN FEET 6 7 10 9 3.0 8 7 B 6 2.0 5 4 3 A 1.0 2 1 7 8 GLASS HEIGHT IN METERS 1600 SS GLASS HEIGHT IN METERS 0 2.0 GLASS HEIGHT IN FEET EC 97911-053 GLASS HEIGHT IN FEET 12 GLASS HEIGHT IN METERS 1.0 GLASS HEIGHT IN METERS GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 23 DEAD LOAD CHARTS (1" INFILL) SPAN IN METERS 13 2.0 11 12 2 1 SPAN IN FEET 8 SPAN IN METERS (1" INFILL) 2.0 GLASS HEIGHT IN FEET 0 1 1 2 2 3 3 4 4 5 5 6 1.0 6 7 7 A = 1/4 POINT LOADING B = 1/8 POINT LOADING 3.0 9 8 7 6 2.0 5 4 B 3 1.0 2 A 1 SPAN IN METERS 2.0 10 3.0 9 8 7 6 2.0 5 4 B 3 1.0 2 2 B 1 1 A 0 0 A 169019 I = 0.598 (24.89 x 104) S = 0.470 (7.70 x 103) SPAN IN FEET 8 ADMD060 1.0 12 12 11 11 169016 I = 0.589 (24.52 x 104) S = 0.456 (7.47 x 103) 0 10 9 8 13 13 12 12 11 11 3.0 8 7 6 2.0 5 4 3 1.0 2 B 1 0 A SPAN IN FEET 0 0 1 (1/4" INFILL) A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1 2 SPAN IN FEET 2 3 3 4 4 5 5 6 1.0 6 7 7 8 SPAN IN METERS 2.0 10 9 3.0 8 7 6 2.0 5 4 3 1.0 SPAN IN FEET 8 kawneer.com © Kawneer Company, Inc., 2013 SPAN IN METERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. (1/4" INFILL) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. DEAD LOAD CHARTS GLASS HEIGHT IN METERS 13 GLASS HEIGHT IN FEET 1600 SS GLASS HEIGHT IN METERS 0 2.0 GLASS HEIGHT IN FEET 10 GLASS HEIGHT IN METERS 1.0 GLASS HEIGHT IN METERS GLASS HEIGHT IN FEET 24 DECEMBER, 2013 EC 97911-053 (1" INFILL) SPAN IN METERS 13 2.0 (1" INFILL) GLASS HEIGHT IN FEET © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0 kawneer.com 1 1 2 2 3 3 (1/4" INFILL) SPAN IN METERS 13 4 4 5 5 6 1.0 6 7 7 A = 1/4 POINT LOADING B = 1/8 POINT LOADING 9 3.0 8 7 6 2.0 5 4 B 3 1.0 2 A 1 SPAN IN METERS 2.0 10 9 3.0 8 7 6 2.0 5 4 B 3 1.0 2 A 169018 I = 0.671 (27.93 x 104) S = 0.514 (8.42 x 103) 1 0 8 SPAN IN FEET ADMD060 1.0 12 12 11 11 0 10 9 8 13 13 12 12 11 11 3.0 8 7 6 2.0 5 4 169015 3 I = 0.659 (27.43 x 104) S = 0.496 (8.13 x 103) 2 B 1 A 1.0 SPAN IN FEET 0 0 1 (1/4" INFILL) A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1 2 2 3 3 4 4 5 5 6 1.0 SPAN IN FEET 6 7 10 9 3.0 8 7 6 2.0 5 4 3 2 B 1.0 1 A 0 7 8 GLASS HEIGHT IN METERS 1600 SS GLASS HEIGHT IN METERS 0 2.0 GLASS HEIGHT IN FEET EC 97911-053 GLASS HEIGHT IN FEET 10 GLASS HEIGHT IN METERS 1.0 GLASS HEIGHT IN METERS GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 25 DEAD LOAD CHARTS (1" INFILL) SPAN IN METERS 13 2.0 0 SPAN IN FEET 8 SPAN IN METERS (1" INFILL) 2.0 1600 SS 26 DECEMBER, 2013 THERMAL CHARTS EC 97911-053 Project Specific U-factor Example Calculation (Based on single bay of Curtain Wall/Window Wall) 6'-0" D.L.O. SPANDREL 9'-0" D.L.O. VISION Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5'-0" D.L.O. Vision Area Example Glass U-factor = 0.48 Btu/(ft2 · h · °F) Vision Area = 5(9 + 8 + 4) = 105.0 ft2 Total Area (Vision) = 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2 Percentage of Vision Glass = (Vision Area ÷ Total Area)100 = (105.0 ÷ 113.2)100 = 93% Spandrel Area Example Spandrel R-value = 15 (ft2 · h · °F)/Btu Spandrel Area = 5(6 + 3) = 45.0 ft2 Total Area (Spandrel) = 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2 Percent of Spandrel = (Spandrel Area ÷ Total Area)100 = (49.0 ÷ 49.6)100 = 91% ADMD060 kawneer.com © Kawneer Company, Inc., 2013 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. VISION 2-1/2" Typ. 3'-0" D.L.O. 4'-0" D.L.O. VISION 31'-3" SPANDREL 8'-0" D.L.O. 2-1/2" Typ. 1600 SS DECEMBER, 2013 EC 97911-053 27 THERMAL CHARTS Vision Area Chart System U-factor vs Percent of Vision Area (N 0.70 E IGN PL S M E A D EX OR F T O COG U-factor 0.53 0.50 0.40 0.30 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 Btu h·ft 2·°F System U-factor Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.80 93% 0.20 95 85 90 75 80 70 Vision Area / Total Area (%) Based on a single curtain wall bay of 93% vision glass and center of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F) System U-factor vs Percent of Spandrel Area Spandrel R-value E IGN PL S M E A D EX OR F T O 3.00 4.00 © Kawneer Company, Inc., 2013 5.00 0.30 0.21 0.20 0.10 91% 95 0.40 ) 11.00 15.00 19.00 30.00 0.50 Btu h·ft 2·°F System U-factor 2.00 0.60 (N Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Spandrel Area Chart 90 85 80 75 70 Spandrel Area / Total Area (%) Based on a single curtain wall bay of 91% spandrel and center of spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F) kawneer.com ADMD060 1600 SS DECEMBER, 2013 THERMAL CHARTS (CAPTURED) EC 97911-053 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. System U-Factor for Vision Glass 0.90 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. (5.00) 0.85 0.80 (4.50) 0.75 0.70 (4.00) System U-Factor 0.45 System U-Factor 0.50 2 0.55 (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) ( m W·°C ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 (3.50) ( m W·°C ) 0.60 COG U-factor Btu h·ft 2·°F 0.65 (3.00) (2.50) 0.40 0.35 (2.00) 0.30 (1.50) 0.25 0.20 95 90 85 80 75 70 0.70 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factors for Spandrel Glass (4.00) 0.65 0.60 (3.50) 0.55 (3.00) 0.45 2.00 (0.35) 0.40 3.00 (0.53) 0.35 4.00 (0.70) 0.30 5.00 (0.88) 0.25 (2.50) 2 0.50 Spandrel R-Value (2.00) (1.50) 0.20 (2.00) 11.00 (1.94) 0.15 15.00 (2.64) 0.10 19.00 (3.34) (1.50) 30.00 (5.28) 0.05 95 90 85 80 75 70 Spandrel Area / Total Area (%) ADMD060 kawneer.com © Kawneer Company, Inc., 2013 Vision Area / Total Area (%) Btu h·ft 2·°F 28 1600 SS DECEMBER, 2013 EC 97911-053 THERMAL CHARTS (CAPTURED) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC 0.90 0.90 0.85 0.85 0.80 0.80 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 29 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.10 95 90 80 85 75 70 Vision Area / Total Area (%) Charts are generated per AAMA 507. 0.90 0.90 0.85 0.85 0.80 0.80 0.75 0.75 0.70 0.70 0.65 0.65 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.10 95 90 80 85 Vision Ares / Total Area (%) Charts are generated per AAMA 507. kawneer.com ADMD060 75 70 System VT 0.60 0.60 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System Visible Transmittance (VT) vs Percent of Vision Area COG VT 1600 SS DECEMBER, 2013 THERMAL PERFORMANCE MATRIX (NFRC SIZE) - (CAPTURED) EC 97911-053 Glass U-Factor 3 Overall U-Factor 4 0.48 0.62 0.46 0.60 0.44 0.59 0.42 0.57 0.40 0.55 0.38 0.54 0.36 0.52 0.34 0.50 0.32 0.49 0.30 0.47 0.28 0.46 0.26 0.44 0.24 0.42 0.22 0.41 0.20 0.39 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.90 0.82 0.90 0.81 0.85 0.78 0.85 0.76 0.80 0.73 0.80 0.72 0.75 0.69 0.75 0.67 0.70 0.64 0.70 0.63 0.65 0.60 0.65 0.58 0.60 0.55 0.60 0.54 0.55 0.51 0.55 0.49 0.50 0.46 0.50 0.45 0.45 0.42 0.45 0.40 0.40 0.37 0.40 0.36 0.35 0.33 0.35 0.31 0.30 0.29 0.30 0.27 0.25 0.24 0.25 0.22 0.20 0.20 0.20 0.18 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). ADMD060 kawneer.com © Kawneer Company, Inc., 2013 SHGC Matrix 2 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 30 1600 SS DECEMBER, 2013 EC 97911-053 31 THERMAL CHARTS (SSG) Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. System U-Factor for Vision Glass 0.90 (5.00) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.85 0.80 (4.50) 0.75 0.70 (4.00) 0.45 2 System U-Factor 0.50 System U-Factor (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) ( m W·°C ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.55 (3.50) ( m W·°C ) 0.60 COG U-factor Btu h·ft 2·°F 0.65 (3.00) (2.50) 0.40 0.35 (2.00) 0.30 (1.50) 0.25 0.20 95 90 85 80 75 70 System U-Factors for Spandrel Glass 0.70 (4.00) 0.65 0.60 (3.50) 0.55 (3.00) 2.00 (0.35) 0.40 0.35 3.00 (0.53) Btu h·ft 2·°F 0.45 (2.50) 2 0.50 Spandrel R-Value © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Vision Area / Total Area (%) (2.00) 0.30 4.00 (0.70) 0.25 5.00 (0.88) (1.50) 0.20 (2.00) 11.00 (1.94) 0.15 15.00 (2.64) 19.00 (3.34) 0.10 30.00 (5.28) 95 0.05 90 85 80 Spandrel Area / Total Area (%) kawneer.com ADMD060 75 70 (1.50) 1600 SS DECEMBER, 2013 THERMAL CHARTS (SSG) EC 97911-053 0.90 0.85 0.85 0.80 0.80 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 System SHGC 0.90 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC 0.15 0.10 95 90 80 85 75 70 Vision Area / Total Area (%) Charts are generated per AAMA 507. 0.90 0.85 0.85 0.80 0.80 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.10 95 90 80 85 75 70 Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD060 kawneer.com © Kawneer Company, Inc., 2013 0.90 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System Visible Transmittance (VT) vs Percent of Vision Area COG VT System VT 32 1600 SS DECEMBER, 2013 EC 97911-053 THERMAL PERFORMANCE MATRIX (NFRC SIZE) - (SSG) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.56 0.46 0.54 0.44 0.53 0.42 0.51 0.40 0.49 0.38 0.48 0.36 0.46 0.34 0.44 0.32 0.42 0.30 0.41 0.28 0.39 0.26 0.37 0.24 0.36 0.22 0.34 0.20 0.32 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.90 0.87 0.90 0.81 0.85 0.82 0.85 0.77 0.80 0.77 0.80 0.72 0.75 0.73 0.75 0.68 0.70 0.68 0.70 0.63 0.65 0.64 0.65 0.59 0.60 0.59 0.60 0.54 0.55 0.55 0.55 0.50 0.50 0.50 0.50 0.45 0.45 0.46 0.45 0.41 0.40 0.41 0.40 0.36 0.35 0.37 0.35 0.32 0.30 0.32 0.30 0.27 0.25 0.28 0.25 0.23 0.20 0.23 0.20 0.18 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). kawneer.com ADMD060 33 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 SS DECEMBER, 2013 BLANK PAGE EC 97911-053 ADMD060 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 34
Similar documents
1600 SS Curtain Wall System
• 1600 SS can be supplied fabricated and KD or in stock lengths • Interlocking mullion design eliminates need for anti-buckling clips • Concealed fastener joinery creates smooth, monolithic appe...
More information1620 Curtain Wall System
modified to expand design flexibility. Please contact your Kawneer representative for further assistance.
More informationTrifab VG 451/451T
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH and WITHOUT HORIZONTALS and ...
More information