ABS Digimatic Indicator ID-C
Transcription
ABS Digimatic Indicator ID-C
Small Tool Instruments and Data Management Standard Digital Indicator ABS Digimatic Indicator ID-C Bulletin No. 1966 Digital indicators offer dramatically improved readability, usability and functionality Digital indicators that offer dramatically improved ease of ABS Digimatic Indicator ID-C The Nakatsugawa plant is in the central industrial park of beautiful Nakatsugawa city, in the Gifu prefecture. This plant specializes in manufacturing sensor products and handles the complete development-to-production cycle for measuring instruments such as dial gages, test indicators, Digimatic indicators, and bore gages. It was opened in 1997 as the 12th Mitutoyo plant in Japan. Using its state-of-the-art production techniques and facilities, this plant continues to provide Mitutoyo products that are praised around the world and used with confidence. ual t c A ize s ual t c A ize s 543-392B 543-472B ABS Digimatic indicator ID-C is a standard digital indicator. A large LCD incorporating 11mm characters (existing products: 8.5mm) is used to improve visibility, and three large, easy-to-press buttons are used in the design to make operations easier to perform. In addition, this affordable product has various measurement functions, including the ability to perform scaling calculations, judge tolerance, hold data, and perform general comparison measurements. 2 ual t c A ize s 543-492B Examples of use reading measurement values, usability and functionality 1. 4. Large LCD The large LCD incorporates 11mm characters giving 1.5 times the character area of existing products (which display 8.5mm characters) making measurement values much easier to read. 2. 11mm Actual size 5. Three large buttons The popular three-large-button design, which is used in products such as the ABS coolant proof Digimatic indicator ID-N/ID-B, makes buttons easier to press and operations easier to perform. ABS Digimatic upright gage 4.267 ABS Digimatic thickness gage 54.267 50 mm reference gage Measured workpiece 54.267 Measured workpiece Switches the measurement mode between ABS and INC. 3. Application products for one-touch quick measurement Various application products are available that enable you to perform one-touch quick measurement of the thickness of small parts, papers, felt, lenses, and pipes, as well as the depth of narrow grooves on cylindrical workpieces, groove depth, and steps. (For details, see pages 8-11.) INC measurement mode Press and hold the SET button (for at least two seconds) to switch the mode. Operation in ABS (preset) measurement mode 330° Zeroset using a reference gage to perform a comparison measurement of the difference between the reference gage and measured workpiece Preset using a reference gage to measure the absolute value from a measurement reference 50 mm reference gage 6. • Switches between the ABS (preset) and INC (zeroset) measurement modes ABS measurement mode 330° rotary display 330° The display can be rotated 330°, allowing use at a position where you can easily read the measurement value. • Power switch • Data output (when connected to an external device) • Data hold (when no external device is connected) • Parameter setting mode Count direction switching, tolerance judgment setting, resolution switching, scale factor setting, and function lock setting Functions that support measurement The ID-C has various functions, including the ability to hold data, Measurement value and tolerance judgment output data, switch the measuring direction, judge tolerance, change the scale factor, and a lock to prevent misoperation. Enlarged display of the tolerance judgment result (For details, see page 6.) ABS Digimatic depth gage Operation in INC (zeroset) measurement mode 7. Expanded lifting capability The ABS (ABSOLUTE) sensor The original Mitutoyo ABS (ABSOLUTE) sensor, which is capable of relocating the origin even after turning the power off, enables you to quickly start multipoint measurement. Also, the ABS measurement mode can be restored even after measurement in the INC mode, where zerosetting is possible at any position, improving work efficiency. The lifting function that moves the spindle up and down has been expanded to improve work efficiency when using the ID-C mounted on a stand. For models that have a 12.7mm measuring range, a lifting lever (special accessory) can be mounted on the left or right side, improving work efficiency and smoothness of movement. A lifting cable (special accessory) provides a maximum of approximately 25.4mm of spindle movement (twice that of existing models). So for models that have a 12.7mm or 25.4mm measuring range, the spindle can be moved through the entire measuring range. (Applied to models that have a 50.8mm measuring range, the spindle can be retracted by approximately 25.4mm from the extended position.) 8. Inspection certificate provided as standard Mitutoyo provides an inspection certificate that includes inspection data as standard to guarantee that every product shipped is of high quality and safe to use. Upon request, we can also calibrate purchased measuring instruments and issue a calibration certificate that proves traceability to national (or international) standards for a fee. To minimize calibration uncertainty as much as possible, both the inspection certificate and calibration certificate are issued after measurement using dedicated testers developed with advanced Mitutoyo measurement technologies. Note that the inspection certificate cannot be used to obtain a calibration certificate because the former does not indicate the date of purchase. Lifting knob (special accessory) By using a lifting knob (special accessory) fitted to the the top of the spindle, you can perform fullstroke operation without directly touching the spindle. 検査成績書 #%24)&)#!4%¬/&¬).30%#4)/. 0RODUCT¬NAME¬¬$IGIMATIC¬)NDICATOR 'RADUATION¬¬MM #ERTIlCATE¬.O -ODEL¬¬)$#8 3ERIAL¬.O¬¬ ¬3TANDARD¬4EMPERATURE 4EMPERATURE¬¬° #ODE¬.O¬¬ -EASURING¬SPAN¬¬MM 1#¬-ANAGER¬¬4+OSUDA )NSPECTION¬STANDARD¬¬-ITUTOYO¬STANDARD¬ Lifting lever (finger hook) Standard accessory (only for models that have a measuring range of 25.4mm or 50.8mm) UNIT¬«M 測定値¬ERROR 指示の最大許容差¬-0%¬OF¬INDICATION 広範囲行き精度/VERALL 戻り誤差(YSTERESIS 繰返精密度2EPEATABILITY PASSED -AXIMUM¬0ERMISSIBLE¬ERROR -0%¬OF¬INDICATION 指示誤差¬%RRORS¬;«M= "ASED¬ON¬¬!3-%¬"- 4RACEABLE¬TO¬¬.-)*!)34¬BY¬*#33¬.O .)34¬VIA¬.O- × ○ ○ × ○ × ○ × ○ × ○¬¬50 ○ × × ○ ׬¬$/7. -ITUTOYO¬#ORPORATION 3 × ○ × ○ ± PASSED ¬/VERALL¬MAGNIlCATION¬AND¬LINEARITY *UDGEMENT¬判定)¬0ASSED¬合格 注¬規格値には量子化誤差±カウント含まず 4HE¬QUANTIZING¬ERROR¬±¬COUNT¬IS EXCLUDED¬FROM¬THE¬SPECIlCATION¬VALUE -ETHOD¬OF¬INSPECTION-)454/9/¬.O¬SIGN If dust or coolant gets into the gap between the spindle and main unit while using the lifting knob, the spindle travel may become rough or the indicator may fail altogether. Therefore avoid using the ID-C in environments containing dust or coolant mist. ERROR UNIT¬«M ! /VERALL¬ 3 (YSTERESIS % 2EPEATABILITY ○ × × ○ × ○ × ○ × ○ × ○ × ○ × ○ × ○ × ○ 位置¬0OSITIONMM ○ × × ○ この検査成績書には安心してご利用いた だけますよう出荷時の検査データを記載して いますが、校正証明書取得用にはご利用できません ABS Digimatic Indicator ID-C SPECIFICATIONS Inch/Metric ISO/JIS Type and ANSI/AGD Type Order No. Measuring range Accuracy*[1 Resolution .00005"/.0001"/.0005"/0.001mm/0.01mm 543-391 543-391B .5" ±.00010"/0.003mm 543-392 543-392B .5" ±.00010"/0.003mm 543-395 543-395B .5" ±.00010"/0.003mm 543-396 543-396B .5" ±.00010"/0.003mm — 543-471B 1" ±.00010"/0.003mm — 543-472B 1" ±.00010"/0.003mm — 543-491B 2" ±.00020"/0.005mm — 543-492B 2" ±.00020"/0.005mm Resolution .0005"/0.01mm 543-401 543-401B .5" ±.0010"/0.02mm 543-402 543-402B .5" ±.0010"/0.02mm 543-405 543-405B .5" ±.0010"/0.02mm 543-406 543-406B .5" ±.0010"/0.02mm — 543-475B 1" ±.0010"/0.02mm — 543-476B 1" ±.0010"/0.02mm — 543-495B 2" ±.0015"/0.04mm — 543-496B 2" ±.0015"/0.04mm Metric Hysteresis* Repeatability* Measuring force Mass Remarks .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm .00010"/0.002mm 1.5N or less 1.5N or less 0.7, 0.6, 0.4N or less 0.7, 0.6, 0.4N or less 1.8N or less 1.8N or less 2.3N or less 2.3N or less 170g 170g 170g 170g 190g 190g 260g 260g — — Low measuring force Low measuring force — — — — .0010"/0.02mm .0010"/0.02mm .0010"/0.02mm .0010"/0.02mm .0010"/0.02mm .0010"/0.02mm .0010"/0.02mm .0010"/0.02mm .0005"/0.01mm .0005"/0.01mm .0005"/0.01mm .0005"/0.01mm .0005"/0.01mm .0005"/0.01mm .0005"/0.01mm .0005"/0.01mm 0.9N or less 0.9N or less 0.5, 0.4, 0.3, 0.2N or less 0.5, 0.4, 0.3, 0.2N or less 1.8N or less 1.8N or less 2.3N or less 2.3N or less 170g 170g 170g 170g 190g 190g 260g 260g — — Low measuring force Low measuring force — — — — ISO/JIS Type Order No. Resolution 0.001mm/0.01mm 543-390 543-390B 543-394 543-394B — 543-470B — 543-490B Resolution 0.01mm 543-400 543-400B 543-404 543-404B — 543-474B — 543-494B Measuring range Accuracy*[1 Hysteresis* Repeatability* Measuring force Mass Remarks 12.7mm 12.7mm 25.4mm 50.8mm 0.003mm 0.003mm 0.003mm 0.005mm 0.002mm 0.002mm 0.002mm 0.002mm 0.002mm 0.002mm 0.002mm 0.002mm 1.5N or less 0.7, 0.6, 0.4N or less 1.8N or less 2.3N or less 170g 170g 190g 260g — Low measuring force — — 12.7mm 12.7mm 25.4mm 50.8mm 0.02mm 0.02mm 0.02mm 0.04mm 0.02mm 0.02mm 0.02mm 0.02mm 0.01mm 0.01mm 0.01mm 0.01mm 0.9N or less 0.5, 0.4, 0.3, 0.2N or less 1.8N or less 2.3N or less 170g 170g 190g 260g — Low measuring force — — : ANS/AGD Type Note) Products with an Order No. suffixed “B” have a flat back, and other models have a back with a lug. * Overall hysteresis and repeatability specifications are valid for normal measurement at 20°C, and the quantizing error of ±1 count is excluded. COMMON SPECIFICATIONS • Display: 6-digit LCD, sign • Contact point: Spherical tip SR = 1.5mm (carbide tipped), part No. 901312 (for ISO/JIS Type) part No. 21BZB005 (for ANSI/AGD Type) • Spindle orientation for measurement: - Standard model that has a 12.7mm measuring range: No restrictions - Standard model that has a 25.4mm or 50.8mm measuring range: Normally at any position between the spindle pointing vertically downward to the spindle horizontal. To perform measurement with the spindle pointing above the horizontal requires a reverse-position coil spring (special accessory). - Low measuring force models: See 'Setting measuring force on low measuring force models' on page 5. 4 • Position detection method: Capacitance type absolute linear encoder • Battery: SR44 (silver oxide button cell) × 1, part No. 938882 • Battery life: Approximately 7,000 hours of continuous use • Maximum response speed: Not restricted (except for scanning measurement) • Service temperature range: 0 to 40°C • Storage temperature range: 0 to 60°C Setting measuring force on low measuring force models •543-404/404B/405/405B/406/406B •543-394/394B/395/395B/396/396B Maximum Spindle orientation Spring Weight (approximately 0.1 N) measuring force Yes Yes 0.5N Yes No 0.4N Pointing vertically downward No Yes 0.3N No No 0.2N Horizontal Yes No 0.2N Note) Operation using configurations other than shown above is not guaranteed. Weight Maximum (approximately 0.1 N) measuring force 0.8N (0.3+0.4+0.1=0.8) Yes Yes 0.6N Yes No Pointing vertically downward 0.4N No Yes No No Not guaranteed Horizontal Not guaranteed Note) Operation using configurations other than shown above is not guaranteed. Spindle orientation Spring DIMENSIONS ISO/JIS Type 19.2 20 50.1 28.8 84.8 70 0 ø8 -0.009 0 ø8 -0.009 19.5 52 25.4mm range models 65.3 M2.5X0.45 7.3 40.8 26 12.7mm range models M2.5X0.45 7.3 19.5 7.6 110.6 97.3 M2.5X0.45 7.3 11 ø59 0 ø8 -0.009 17 21.2 31.5 ø59 ø54 .5 ø6 54.4 46.5 19.2 11 85.2 5 ø59 31.5 57.7 ø10.9 50.8mm range models ANSI/AGD Type ø 10.9 .43" 28.8 1.13" 19.2 .76" 19 3/4" 31.5 11 1.24" .43" 31.5 11 1.24" .43" 19.2 .76" 85.2 3.35" 59 2.32" ø 54 2.13" ø 59 2.32" 57.7 2.27" ø 6.5 ø 1/4" 83.85 3.30" 67.7 2.67" 17.2 .68" 42.15 1.66" 6.35 1/4" · Contact point No.4-48 thread 25.4mm range models 52 2.05" * is the symbol denoting American Gage Design (AGD). It shows conformance to certain dimensions for Dial Indicators, as specified in ASME / AGD 2, intended to promote interchangeability. Only applicable to models with an "E" suffix. 26 1.02" 12.7mm range models 66.65 2.62" 6.35 1/4" ø 9.52 -0.03 .375" 109.65 4.32" 95 3.74" 0 17.2 .68" 7.6 .3" ø 59 2.32" 0 ø9.52 -0.03 .375" · Contact point No.4-48 thread 6.35 1/4" 50.8 2" 44.2 1.74" 20 14.7 .79" .58" 50.1 1.97" 6.35 1/4" 0 9.52 -0.03 .375" · Contact point No.4-48 thread 50.8mm range models 5 Functions and accessories Functions • Zero-setting function (INC measurement mode) • Preset function (ABS scale origin setting) The preset value can be changed easily by using the SET (digit movement) and MODE (value change) buttons. • 330° rotary display 330° 330° • Data output (when connected to an external device) From the output terminal, measurement data can be output to a PC via a compact printer, Digimatic mini processor DP-1VR, or input tool by pressing the button below the display. Wireless transmission of measurement data to a PC can also be performed using the measurement data wireless communication system U-WAVE. • Resolution switching (For 0.001mm or .00005" resolution models) Models with 0.001mm resolution are capable of displaying in 0.01mm resolution. Models with .00005" resolution are capable of displaying in .0001" and .0005" resolution. Select the resolution according to the application. • Switching the direction The measuring direction can be reversed. • Judging the tolerance Performs judgment (OK, +NG, -NG) according to the set upper and lower limit values and displays the result as a symbol. Enlarged display of the OK and NG symbols is possible. • Display value holding (when no external device is connected) Connecting cables for data output (special accessory) 1m: No.905338 No.264-504 2m: No.905409 DP-1VR (special accessory) Input tool No.264-012-10 IT-012U (special accessory) • Calculation: f(x) = Ax Mounting the ID-C on a measuring jig and setting the calculation factor (to any value) allows direct measurement without using a conversion table and improves measurement efficiency. Measurement value and tolerance judgment • Function locking Ensures reliability of measurement by locking the settings to prevent preset function settings from being changed by mistake. Enlarged display of the tolerance judgment result • Low battery voltage alarm • Error alarm 6 Standard accessories • Interchangeable contact points for Mitutoyo dial gages • Operation manual • Inspection certificate 1 Lifting lever (finger hook) • Various backs for standard Mitutoyo (2 series) dial gages • Reverse-position coil spring Part No. 938882 • Weight (only for low measuring force models) Part No. 02ACA571 (for models that have a 25.4mm measuring range) Part No. 02ACA773 (for models that have a 50.8mm measuring range) Special accessories 4 6 • Connecting cable (1m), part No. 905338 • Connecting cable (2m), part No. 905409 Lifting lever Part No. 21EZA198 (for models that have a 12.7mm measuring range ISO/JIS Type) Part No. 21EZA199 (for models that have a 12.7mm measuring range ANSI/ADG Type) 3 Needle Various types of contact points are available. • Silver oxide button cell for the monitor: SR44 × 1 2 Flat Shell (Only for models that have a 25.4mm or 50.8mm measuring range) • U-WAVE (measurement data wireless communication system) • Digimatic mini processor DP-1VR No. 264-504 • Multiplexer MUX-10F, No. 264-002 • Display unit EC-101D, No. 542-007 • Input tool (USB keyboard signal conversion type) IT-012U, No. 264-012-10 Lifting cable, part No. 540774 Lifting knob 8 2 Part No. 21EZA105 (for models that have a 12.7mm measuring range ISO/JIS Type) Part No. 21EZA150 (for models that have a 12.7mm measuring range ANSI/ADG Type) Part No. 21EZA197 (for models that have a 25.4mm measuring range) Part No. 21EZA200 (for models that have a 50.8mm measuring range) 7 4 5 No.7007 1 3 • Recommended stands 5 Dial gage stand, No. 7001 7002 7007 6 Granite comparator stand BSG-30, No. 215-154 7 Comparator stand BSC-30, No. 215-504 8 Comparator stand BSG-20, No. 215-151 Various Digimatic Indicators 2 1 5 2 3 3 4 1 5 4 6 7 8 7 8 6 7 ID-C: Standard Digital Indicator ID-N/B: waterproof, 35mm slim body with various functions ID-H: infrared remote controller, high accuracy, and various functions ID-S: cost-effective type that has basic functions ID-U1025: general-purpose type that has a 25.4mm measuring range ID-C112RB: has a built-in calculation function ID-C112A: has a peak hold function ID-C112GB: internal diameter measuring instrument dedicated to cylinder gages Application Products Application Products ABS Digimatic Thickness Gage 547-300S 547-400S 547-320S Unit: mm • For one-touch quick measurement of the thickness of small parts, papers, and felt • Rust-free ceramic contact point and anvil (except No. 547-401) 120 ø10 30 ø10 85 175 547-301 Inch/Metric 547-321 ANSI/AGD Type Parallelism of contact point and anvil ø10mm flat .0005" or less ø10mm flat .0005" or less ø6.3mm flat (carbide tipped) .0001" or less Order No. Resolution Measuring range Throat depth Contact point and anvil Accuracy Measuring force 547-300S 547-320S 547-400S .0005"/0.01mm .0005"/0.01mm .00005"/0.001mm 0~.4"/0~10mm 30mm 0~.4"/0~10mm 120mm 0~.47"/0~12mm 21mm ±.001" ±.001" ±.0001" 1.5N or less 1.5N or less 3.5N or less Metric ISO/JIS Type Parallelism of contact point and anvil ø10mm flat 10µm or less ø10mm flat 10µm or less ø6.3mm flat (carbide tipped) 3µm or less Order No. Resolution Measuring range Throat depth Contact point and anvil Accuracy Measuring force 547-301 547-321 547-401 0.01mm 0.01mm 0.001mm 0~10mm 0~10mm 0~12mm ±20µm ±20µm ± 3µm 1.5N or less 1.5N or less 3.5N or less 30mm 120mm 21mm Note) 1. Changing the contact point requires total adjustment, including the main display unit. Contact Mitutoyo for advice. 2. The accuracy specification does not include the quantizing error of ±1 count. 3. Left-handed models can be supplied to special order. 8 ABS Digimatic Lens Meter Unit: mm Flat contact point Contact point 9.3 Spherical contact Flat contact point point Anvil Concave lens Anvil Convex lens Sø4 spherical contact point Standard accessory Anvil adjustment: 12 mm SR3 30 SR3 ø6 ø4.8 9.3 SR2 Anvil Moon lens 30.3 9.3 • Designed for measuring the thickness of concavo-convex lenses and flat objects • The thickness of flat objects can be measured by replacing the anvil. • Includes a spherical contact point. 547-312S ANSI/AGD Type Order No. Resolution 547-312S .0005"/0.01mm 0~.4"/0~10mm 30mm Metric Measuring range Throat depth SR2 Anvil adjustment 12mm 30 ø6 ø4.8 30 Inch/Metric (Throat depth) 85 Accuracy Measuring force Anvil displacement: 12 mm SR3 ±.001" or less 85 1.5N or less ISO/JIS Type Order No. Resolution Measuring range Throat depth Anvil adjustment Accuracy Measuring force 547-313 0.01mm 0~10mm 12mm ±20µm or less 1.5N or less 30mm Note) The accuracy specification does not include the quantizing error of ±1 count. Left-handed models can be supplied to special order. ABS Digimatic Pipe Gage Unit: mm • Designed for measuring the thickness of pipes and curved boards ø3 ø3 Contact point Tip: ø3.5 Effective throat depth 20 21 Inch/Metric 85 ANSI/AGD Type Order No. Resolution 547-361S .0005"/0.01mm 0~.4"/0~10mm 20mm Measuring range Throat depth Minimum inside diameter of pipe ø3.5mm Accuracy Measuring force ±.001" or less 1.5N or less ø3 547-361S Anvil Metric ISO/JIS Type Order No. Resolution Measuring range Throat depth 547-360 0.01mm 0~10mm 20mm Minimum inside diameter of pipe ø3.5mm アンビル 有効差し 球ø3.5 込み深さ Accuracy 21 Measuring force ±20µm or less 1.5N or less Note) 1. Changing the contact point requires total adjustment, including the main display unit. Contact Mitutoyo for advice. 2. The accuracy specification does not include the quantizing error of ±1 count. 3. Left-handed models can be supplied to special order. 9 Application Products Unit: mm ABS Digimatic Groove Gage • Best suited for measuring the depth of narrow grooves on cylindrical workpieces • The contact point and measuring face of the anvil are 1mm thick blades. Inch/Metric 66 30.3 (Throat depth) 85 ANSI/AGD Type Resolution 547-316S .0005"/0.01mm Measuring range Throat depth 0~4"/0~10mm 30mm ontact point and anvil Accuracy C Measuring force dimensions (W × D) 6.5mm x 1mm ±.001" or less 1.5N or less 30 ø6.5 55 Order No. Metric 1 Contact point Anvil ISO/JIS Type Contact point and anvil Accuracy Measuring range Throat Measuring force depth dimensions (W × D) 1 85 547-315 0.01mm 0~10mm 30mm 6.5mm x 1mm ±20µm or less 1.5N or less Note) 1. Changing the contact point requires total adjustment, including the main display unit. Contact Mitutoyo for advice. 2. The accuracy specification does not include the quantizing error of ±1 count. 3. Left-handed models can be supplied to special order. Order No. 547-316S Resolution Unit: mm ø59 ABS Digimatic Depth Gage (67) (105) • Suitable for measuring the depth of holes, narrow grooves, and steps. • The lifting lever can be used either on the left or right sides. 17 (10) (35) (11) ø16 547-218S Inch/Metric Order No. 547-217S 547-218S 547-257S 547-258S Metric Order No. ANSI/AGD Type Measuring range .0005"/0.01mm 0~8" .0005"/0.01mm 0~8" .00005"/0.001mm 0~8" .00005"/0.001mm 0~8" Resolution Stroke Accuracy .5" .5" .5" .5" ±.001" or less ±.001" or less ±.0002" or less ±.0002" or less Measuring force 1.5N or less 1.5N or less 1.5N or less 1.5N or less Base Length 2.5" 4" 2.5" 4" Width .63" .63" .63" .63" Contact point: Carbldetipped ball Flatness .0002" or less .0002" or less 21JAZA242 .00008" or less .00008" or less ø5 ø6 SR 1.5 A Extension rods 4 pcs. (.5",1",2",4") 4 pcs. (.5",1",2",4") 4 pcs. (.5",1",2",4") 4 pcs. (.5",1",2",4") ISO/JIS Type Resolution Measuring Stroke range Accuracy 547-211 0.01mm ±20µm 547-212 0~200mm 12mm 547-251 0.001mm ±5µm 547-252 Note) The accuracy specification does not include the quantizing error of ±1 count. Base Length Width Flatness 63.5mm 1.5N or less 5µm or less 101.6mm 16mm 63.5mm 1.5N or less 2µm or less 101.6mm Measuring force 10 Contact point: CarbldeExtension rods tipped ball 21JAA224 5 pcs. (10, 20, 30, 30, 100mm) Unit: mm 40 ABS Digimatic Bench Gage ø59 92 60 5 Support plate 547-066S Inch/Metric Order No. 547-066S Metric ø20 55 Effective throat depth ø8 ø6.3 10 45 • The support plate allows easy reading by tilting the anvil. • Carbide measuring faces (for the contact point and anvil) • The lifting lever can be used either on the left or right sides. Flat anvil ANSI/AGD Type Indicator stroke .5" Resolution Remarks (contact point) Effective throat depth Workpiece height .0005"/0.01mm .248" DIA flat type .59" 1" Accuracy ±.001" or less Measuring force 1.5N or less Resolution 0.01mm Accuracy Measuring force ±20µm or less 1.5N or less ISO/JIS Type Order No. 547-064 Indicator stroke 12mm Workpiece height ø20mm Effective throat depth Anvil adjustment 15mm 13mm Note) The accuracy specification does not include the quantizing error of ±1 count. ABS Digimatic Upright Gage • Best suited for inspection of small parts at a site • Carbide ball contact point • The lifting lever that is a standard accessory for No. 547-054, 547-034S can be used either on the left or right sides. Anvil (hardened steel) Effective measuring range Unit: mm SR 35 12 115 1.5 ø40 547-035S Inch/Metric Order No. 547-034S 547-033S 547-035S Metric Order No. 547-054 547-053 547-055 Center of anvil 1 Measuring depth 45 20 95 Center of contact point 60 ANSI/AGD Type Resolution .0005"/0.01mm .00005"/0.001mm .00005"/0.001mm Measuring range .5" .5" .5" Anvil 1.57" DIA steel type 1.97" DIA ceramic type 1.57" DIA steel type Workpiece height 1.2" 1.2" 1.2" Accuracy ±.001" or less ±.0001" or less ±.0001" or less Measuring range 12.7mm 12.7mm 12.7mm Anvil ø40mm (steel type) ø50mm (ceramic type) ø40mm (steel type) Workpiece height Accuracy ±20µm or less ± 3µm or less ± 3µm or less Measuring force 1.5N or less ISO/JIS Type Resolution 0.01mm 0.001mm 0.001mm 30mm Measuring force 1.5N or less Note) 1. The lifting lever (part No. 21EZA198) is a standard accessory for 547-054. 2. The lifting lever (part No. 21EZA199) is a standard accessory for 547-034S. 3. The lifting cable (part No. 540774) is a standard accessory for 547-055, 547-033S, 547-035S. 4. The accuracy specification does not include the quantizing error of ±1 count. • The ABS (ABSOLUTE) scale used in these products is a capacitance type absolute encoder. Its patent has been registered in Japan, the U.S., the U.K., Germany, and China. 11 Export permission by the Japanese government may be required for exporting our products according to the Foreign Exchange and Foreign Trade Law. Please consult our sales office near you before you export our products or you offer technical information to a nonresident. One Number to Serve You Better 1-888-MITUTOYO (1-888-648-8869) Aurora, Illinois (Corporate Headquarters) Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this printed matter as well as other technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs. The stated standards, similar technical regulations, descriptions and illustrations of the products were valid at the time of printing. In addition, the latest applicable version of our General Trading Conditions will apply. Only quotations submitted by ourselves may be regarded as definitive. Mitutoyo products are subject to US Export Administration Regulations (EAR). Re-export or relocation of Mitutoyo products may require prior approval by an appropriate governing authority. Trademarks and Registrations Designations used by companies to distinguish their products are often claimed as trademarks. In all instances where Mitutoyo America Corporation is aware of a claim, the product names appear in initial capital or all capital letters. The appropriate companies should be contacted for more complete trademark and registration information. We reserve the right to change specifications and prices without notice. © 2009 Mitutoyo America Corporation, Aurora IL 0409-09 Printed in USA, June 2009 Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this pamphlet, as well as other technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs, dimensions and weights. Westford, Massachusetts Huntersville, North Carolina Mason, Ohio Plymouth, Michigan Mitutoyo Corporation City of Industry, California 20-1, Sakado 1-chome, Takatsu-ku, Kawasaki-shi, Kanagawa 213-8533, Japan T +81 (0) 44 813-8230 F +81 (0) 44 813-8231 http://www.mitutoyo.co.jp
Similar documents
ABS Digimatic Indicator ID-C
- Standard model that has a 12.7mm measuring range: No restrictions - Standard model that has a 25.4mm or 50.8mm measuring range: Normally at any position between the spindle pointing verticall...
More information