ABS Digimatic Indicator ID-C

Transcription

ABS Digimatic Indicator ID-C
Small Tool Instruments and Data Management
Standard Digital Indicator
ABS Digimatic Indicator ID-C
Bulletin No. 1966
Digital indicators offer dramatically improved
readability, usability and functionality
Digital indicators that offer dramatically improved ease of
ABS Digimatic Indicator ID-C
The Nakatsugawa plant is in the central industrial park of beautiful Nakatsugawa city, in the Gifu
prefecture. This plant specializes in manufacturing sensor products and handles the complete
development-to-production cycle for measuring instruments such as dial gages, test indicators,
Digimatic indicators, and bore gages. It was opened in 1997 as the 12th Mitutoyo plant in Japan.
Using its state-of-the-art production techniques and facilities, this plant continues to provide
Mitutoyo products that are praised around the world and used with confidence.
ual
t
c
A ize
s
ual
t
c
A ize
s
543-392B
543-472B
ABS Digimatic indicator ID-C is a standard digital indicator. A large
LCD incorporating 11mm characters (existing products: 8.5mm) is used
to improve visibility, and three large, easy-to-press buttons are used
in the design to make operations easier to perform. In addition, this
affordable product has various measurement functions, including the
ability to perform scaling calculations, judge tolerance, hold data, and
perform general comparison measurements.
2
ual
t
c
A ize
s
543-492B
Examples of use
reading measurement values, usability and functionality
1.
4.
Large LCD
The large LCD incorporates
11mm characters giving 1.5
times the character area of
existing products (which display
8.5mm characters) making
measurement values much
easier to read.
2.
11mm
Actual size
5.
Three large buttons
The popular three-large-button design, which is used in products such as the ABS
coolant proof Digimatic indicator ID-N/ID-B, makes buttons easier to press and
operations easier to perform.
ABS Digimatic
upright gage
4.267
ABS Digimatic
thickness gage
54.267
50 mm
reference
gage
Measured workpiece
54.267
Measured workpiece
Switches the measurement
mode between ABS and INC.
3.
Application products for one-touch quick
measurement
Various application products are available that enable you to perform one-touch
quick measurement of the thickness of small parts, papers, felt, lenses, and
pipes, as well as the depth of narrow grooves on cylindrical workpieces, groove
depth, and steps.
(For details, see pages 8-11.)
INC measurement mode
Press and hold the SET button
(for at least two seconds) to
switch the mode.
Operation in ABS (preset) measurement mode
330°
Zeroset using a reference gage to perform
a comparison measurement of the difference
between the reference gage and measured
workpiece
Preset using a reference gage to measure the
absolute value from a measurement reference
50 mm
reference
gage
6.
• Switches between the ABS (preset) and
INC (zeroset) measurement modes
ABS measurement mode
330° rotary display 330°
The display can be rotated 330°,
allowing use at a position where you
can easily read the measurement
value.
• Power switch
• Data output (when connected to an
external device)
• Data hold (when no external device is
connected)
• Parameter setting mode
Count direction switching, tolerance judgment
setting, resolution switching, scale factor
setting, and function lock setting
Functions that support measurement
The ID-C has various functions,
including the ability to hold data,
Measurement value and tolerance judgment
output data, switch the measuring
direction, judge tolerance, change
the scale factor, and a lock to prevent
misoperation.
Enlarged display of the tolerance judgment result
(For details, see page 6.)
ABS Digimatic
depth gage
Operation in INC (zeroset) measurement mode
7.
Expanded lifting capability
The ABS (ABSOLUTE) sensor
The original Mitutoyo ABS (ABSOLUTE) sensor, which is capable of relocating
the origin even after turning the power off, enables you to quickly start multipoint measurement. Also, the ABS measurement mode can be restored even
after measurement in the INC mode, where zerosetting
is possible at any position, improving work efficiency.
The lifting function that moves the spindle up and down has been expanded to
improve work efficiency when using the ID-C mounted on a stand.
For models that have a 12.7mm measuring range,
a lifting lever (special accessory) can be mounted
on the left or right side, improving work efficiency
and smoothness of movement.
A lifting cable (special accessory) provides a maximum
of approximately 25.4mm of spindle movement (twice
that of existing models). So for models that have a
12.7mm or 25.4mm measuring range, the spindle can
be moved through the entire measuring range. (Applied
to models that have a 50.8mm measuring range, the
spindle can be retracted by approximately 25.4mm from
the extended position.)
8.
Inspection certificate provided as standard
Mitutoyo provides an inspection certificate that includes inspection data as
standard to guarantee that every product shipped is of high quality and safe
to use. Upon request, we can also calibrate purchased measuring instruments
and issue a calibration certificate that proves traceability to national (or
international) standards for a fee. To minimize calibration uncertainty as much
as possible, both the inspection certificate and calibration certificate are issued
after measurement using dedicated testers developed with advanced Mitutoyo
measurement technologies. Note that the inspection certificate cannot be used
to obtain a calibration certificate because the former does not indicate the date
of purchase.
Lifting knob (special accessory)
By using a lifting knob (special accessory) fitted to
the the top of the spindle, you can perform fullstroke operation without directly touching the
spindle.
検査成績書
#%24)&)#!4%¬/&¬).30%#4)/.
0RODUCT¬NAME¬¬$IGIMATIC¬)NDICATOR
'RADUATION¬¬MM
#ERTIlCATE¬.O
-ODEL¬¬)$#8
3ERIAL¬.O¬¬
¬3TANDARD¬4EMPERATURE
4EMPERATURE¬¬°
#ODE¬.O¬¬
-EASURING¬SPAN¬¬MM
1#¬-ANAGER¬¬4+OSUDA
)NSPECTION¬STANDARD¬¬-ITUTOYO¬STANDARD¬
Lifting lever (finger hook)
Standard accessory (only for models that have a measuring range of
25.4mm or 50.8mm)
UNIT¬«M 測定値¬ERROR
指示の最大許容差¬-0%¬OF¬INDICATION
広範囲行き精度/VERALL
戻り誤差(YSTERESIS
繰返精密度2EPEATABILITY
PASSED
-AXIMUM¬0ERMISSIBLE¬ERROR
-0%¬OF¬INDICATION
指示誤差¬%RRORS¬;«M=
"ASED¬ON¬¬!3-%¬"-
4RACEABLE¬TO¬¬.-)*!)34¬BY¬*#33¬.O
.)34¬VIA¬.O-
×
○
○
×
○
×
○
×
○
×
○¬¬50
○
×
×
○
׬¬$/7.
-ITUTOYO¬#ORPORATION
3
×
○
×
○
±
PASSED
¬/VERALL¬MAGNIlCATION¬AND¬LINEARITY
*UDGEMENT¬判定)¬0ASSED¬合格
注¬規格値には量子化誤差±カウント含まず
4HE¬QUANTIZING¬ERROR¬±¬COUNT¬IS
EXCLUDED¬FROM¬THE¬SPECIlCATION¬VALUE
-ETHOD¬OF¬INSPECTION-)454/9/¬.O¬SIGN
If dust or coolant gets into the gap between the spindle and main unit while using the
lifting knob, the spindle travel may become rough or the indicator may fail altogether.
Therefore avoid using the ID-C in environments containing dust or coolant mist.
ERROR
UNIT¬«M
! /VERALL¬
3 (YSTERESIS
% 2EPEATABILITY
○
×
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
×
○
位置¬0OSITIONMM
○
×
×
○
この検査成績書には安心してご利用いた
だけますよう出荷時の検査データを記載して
いますが、校正証明書取得用にはご利用できません
ABS Digimatic Indicator ID-C
SPECIFICATIONS
Inch/Metric
ISO/JIS Type and ANSI/AGD Type
Order No.
Measuring range Accuracy*[1
Resolution .00005"/.0001"/.0005"/0.001mm/0.01mm
543-391
543-391B
.5"
±.00010"/0.003mm
543-392
543-392B
.5"
±.00010"/0.003mm
543-395
543-395B
.5"
±.00010"/0.003mm
543-396
543-396B
.5"
±.00010"/0.003mm
—
543-471B
1"
±.00010"/0.003mm
—
543-472B
1"
±.00010"/0.003mm
—
543-491B
2"
±.00020"/0.005mm
—
543-492B
2"
±.00020"/0.005mm
Resolution .0005"/0.01mm
543-401
543-401B
.5"
±.0010"/0.02mm
543-402
543-402B
.5"
±.0010"/0.02mm
543-405
543-405B
.5"
±.0010"/0.02mm
543-406
543-406B
.5"
±.0010"/0.02mm
—
543-475B
1"
±.0010"/0.02mm
—
543-476B
1"
±.0010"/0.02mm
—
543-495B
2"
±.0015"/0.04mm
—
543-496B
2"
±.0015"/0.04mm
Metric
Hysteresis*
Repeatability*
Measuring force
Mass
Remarks
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
.00010"/0.002mm
1.5N or less
1.5N or less
0.7, 0.6, 0.4N or less
0.7, 0.6, 0.4N or less
1.8N or less
1.8N or less
2.3N or less
2.3N or less
170g
170g
170g
170g
190g
190g
260g
260g
—
—
Low measuring force
Low measuring force
—
—
—
—
.0010"/0.02mm
.0010"/0.02mm
.0010"/0.02mm
.0010"/0.02mm
.0010"/0.02mm
.0010"/0.02mm
.0010"/0.02mm
.0010"/0.02mm
.0005"/0.01mm
.0005"/0.01mm
.0005"/0.01mm
.0005"/0.01mm
.0005"/0.01mm
.0005"/0.01mm
.0005"/0.01mm
.0005"/0.01mm
0.9N or less
0.9N or less
0.5, 0.4, 0.3, 0.2N or less
0.5, 0.4, 0.3, 0.2N or less
1.8N or less
1.8N or less
2.3N or less
2.3N or less
170g
170g
170g
170g
190g
190g
260g
260g
—
—
Low measuring force
Low measuring force
—
—
—
—
ISO/JIS Type
Order No.
Resolution 0.001mm/0.01mm
543-390
543-390B
543-394
543-394B
—
543-470B
—
543-490B
Resolution 0.01mm
543-400
543-400B
543-404
543-404B
—
543-474B
—
543-494B
Measuring range Accuracy*[1
Hysteresis*
Repeatability*
Measuring force
Mass
Remarks
12.7mm
12.7mm
25.4mm
50.8mm
0.003mm
0.003mm
0.003mm
0.005mm
0.002mm
0.002mm
0.002mm
0.002mm
0.002mm
0.002mm
0.002mm
0.002mm
1.5N or less
0.7, 0.6, 0.4N or less
1.8N or less
2.3N or less
170g
170g
190g
260g
—
Low measuring force
—
—
12.7mm
12.7mm
25.4mm
50.8mm
0.02mm
0.02mm
0.02mm
0.04mm
0.02mm
0.02mm
0.02mm
0.02mm
0.01mm
0.01mm
0.01mm
0.01mm
0.9N or less
0.5, 0.4, 0.3, 0.2N or less
1.8N or less
2.3N or less
170g
170g
190g
260g
—
Low measuring force
—
—
: ANS/AGD Type
Note) Products with an Order No. suffixed “B” have a flat back, and other models have a back with a lug.
* Overall hysteresis and repeatability specifications are valid for normal measurement at 20°C, and the quantizing error of ±1 count is excluded.
COMMON SPECIFICATIONS
• Display: 6-digit LCD, sign
• Contact point: Spherical tip SR = 1.5mm (carbide tipped),
part No. 901312 (for ISO/JIS Type)
part No. 21BZB005 (for ANSI/AGD Type)
• Spindle orientation for measurement:
- Standard model that has a 12.7mm measuring range: No restrictions
- Standard model that has a 25.4mm or 50.8mm measuring range: Normally
at any position between the spindle pointing vertically downward to the
spindle horizontal. To perform measurement with the spindle pointing above
the horizontal requires a reverse-position coil spring (special accessory).
- Low measuring force models: See 'Setting measuring force on low
measuring force models' on page 5.
4
• Position detection method: Capacitance type absolute linear encoder
• Battery: SR44 (silver oxide button cell) × 1, part No. 938882
• Battery life: Approximately 7,000 hours of continuous use
• Maximum response speed: Not restricted (except for scanning measurement)
• Service temperature range: 0 to 40°C
• Storage temperature range: 0 to 60°C
Setting measuring force on low measuring force models
•543-404/404B/405/405B/406/406B
•543-394/394B/395/395B/396/396B
Maximum
Spindle orientation
Spring Weight
(approximately 0.1 N) measuring force
Yes
Yes
0.5N
Yes
No
0.4N
Pointing vertically downward
No
Yes
0.3N
No
No
0.2N
Horizontal
Yes
No
0.2N
Note) Operation using configurations other than shown above is not guaranteed.
Weight
Maximum
(approximately 0.1 N) measuring force
0.8N (0.3+0.4+0.1=0.8)
Yes
Yes
0.6N
Yes
No
Pointing vertically downward
0.4N
No
Yes
No
No
Not guaranteed
Horizontal
Not guaranteed
Note) Operation using configurations other than shown above is not guaranteed.
Spindle orientation
Spring
DIMENSIONS
ISO/JIS Type
19.2
20
50.1
28.8
84.8
70
0
ø8 -0.009
0
ø8 -0.009
19.5
52
25.4mm range models
65.3
M2.5X0.45
7.3
40.8
26
12.7mm range models
M2.5X0.45
7.3
19.5
7.6
110.6
97.3
M2.5X0.45
7.3
11
ø59
0
ø8 -0.009
17
21.2
31.5
ø59
ø54
.5
ø6
54.4
46.5
19.2
11
85.2
5
ø59
31.5
57.7
ø10.9
50.8mm range models
ANSI/AGD Type
ø 10.9
.43"
28.8
1.13"
19.2
.76"
19
3/4"
31.5 11
1.24" .43"
31.5 11
1.24" .43"
19.2
.76"
85.2
3.35"
59
2.32"
ø 54
2.13"
ø 59
2.32"
57.7
2.27"
ø
6.5
ø 1/4"
83.85
3.30"
67.7
2.67"
17.2
.68"
42.15
1.66"
6.35
1/4"
· Contact point
No.4-48 thread
25.4mm range models
52
2.05"
* is the symbol denoting American Gage Design (AGD).
It shows conformance to certain dimensions for Dial Indicators,
as specified in ASME / AGD 2, intended to promote interchangeability.
Only applicable to models with an "E" suffix.
26
1.02"
12.7mm range models
66.65
2.62"
6.35
1/4"
ø 9.52 -0.03
.375"
109.65
4.32"
95
3.74"
0
17.2
.68"
7.6
.3"
ø 59
2.32"
0
ø9.52 -0.03
.375"
· Contact point
No.4-48 thread
6.35
1/4"
50.8
2"
44.2
1.74"
20 14.7
.79" .58"
50.1
1.97"
6.35
1/4"
0
9.52 -0.03
.375"
· Contact point
No.4-48 thread
50.8mm range models
5
Functions and accessories
Functions
• Zero-setting function
(INC measurement mode)
• Preset function (ABS scale origin setting)
The preset value can be changed easily by using the
SET (digit movement) and MODE (value change)
buttons.
• 330° rotary display
330°
330°
• Data output
(when connected to an external device)
From the output terminal, measurement data can
be output to a PC via a compact printer, Digimatic
mini processor DP-1VR, or input tool by pressing
the button below the display. Wireless transmission
of measurement data to a PC can also be performed
using the measurement data wireless communication
system U-WAVE.
• Resolution switching
(For 0.001mm or .00005" resolution models)
Models with 0.001mm resolution are capable of
displaying in 0.01mm resolution. Models with
.00005" resolution are capable of displaying in
.0001" and .0005" resolution. Select the resolution
according to the application.
• Switching the direction
The measuring direction can be reversed.
• Judging the tolerance
Performs judgment (OK, +NG, -NG) according to
the set upper and lower limit values and displays
the result as a symbol. Enlarged display of the OK
and NG symbols is possible.
• Display value holding
(when no external device is connected)
Connecting cables for data output (special accessory)
1m: No.905338
No.264-504
2m: No.905409
DP-1VR
(special accessory)
Input tool
No.264-012-10 IT-012U (special accessory)
• Calculation: f(x) = Ax
Mounting the ID-C on a measuring jig and setting
the calculation factor (to any value) allows direct
measurement without using a conversion table and
improves measurement efficiency.
Measurement value and
tolerance judgment
• Function locking
Ensures reliability of measurement by locking the
settings to prevent preset function settings from
being changed by mistake.
Enlarged display of the
tolerance judgment result
• Low battery voltage alarm
• Error alarm
6
Standard accessories
• Interchangeable contact points for Mitutoyo dial gages
• Operation manual
• Inspection certificate
1 Lifting lever (finger hook)
• Various backs for standard Mitutoyo (2 series) dial gages
• Reverse-position coil spring
Part No. 938882
• Weight (only for low measuring force models)
Part No. 02ACA571
(for models that have a 25.4mm measuring range)
Part No. 02ACA773
(for models that have a 50.8mm measuring range)
Special accessories
4
6
• Connecting cable (1m), part No. 905338
• Connecting cable (2m), part No. 905409
Lifting lever
Part No. 21EZA198
(for models that have a 12.7mm measuring range ISO/JIS Type)
Part No. 21EZA199
(for models that have a 12.7mm measuring range ANSI/ADG Type)
3
Needle
Various types of contact points are available.
• Silver oxide button cell for the monitor: SR44 × 1
2
Flat
Shell
(Only for models that have a 25.4mm or 50.8mm measuring range)
• U-WAVE
(measurement data wireless communication system)
• Digimatic mini processor DP-1VR No. 264-504
• Multiplexer MUX-10F, No. 264-002
• Display unit EC-101D, No. 542-007
• Input tool (USB keyboard signal conversion type)
IT-012U, No. 264-012-10
Lifting cable, part No. 540774
Lifting knob
8
2
Part No. 21EZA105
(for models that have a 12.7mm measuring range ISO/JIS Type)
Part No. 21EZA150
(for models that have a 12.7mm measuring range ANSI/ADG Type)
Part No. 21EZA197
(for models that have a 25.4mm measuring range)
Part No. 21EZA200
(for models that have a 50.8mm measuring range)
7
4
5 No.7007
1
3
• Recommended stands
5 Dial gage stand, No. 7001 7002 7007
6 Granite comparator stand BSG-30, No. 215-154
7 Comparator stand BSC-30, No. 215-504
8 Comparator stand BSG-20, No. 215-151
Various Digimatic Indicators
2
1
5
2
3
3
4
1
5
4
6
7
8
7
8
6
7
ID-C: Standard Digital Indicator
ID-N/B: waterproof, 35mm slim body
with various functions
ID-H: infrared remote controller, high
accuracy, and various functions
ID-S: cost-effective type that has basic
functions
ID-U1025: general-purpose type that
has a 25.4mm measuring range
ID-C112RB: has a built-in calculation
function
ID-C112A: has a peak hold function
ID-C112GB: internal diameter measuring
instrument dedicated to cylinder gages
Application Products
Application Products
ABS Digimatic Thickness Gage
547-300S
547-400S
547-320S
Unit: mm
• For one-touch quick measurement of the thickness of small parts,
papers, and felt
• Rust-free ceramic contact point and anvil (except No. 547-401)
120
ø10
30
ø10
85
175
547-301
Inch/Metric
547-321
ANSI/AGD Type
Parallelism of contact point
and anvil
ø10mm flat
.0005" or less
ø10mm flat
.0005" or less
ø6.3mm flat (carbide tipped) .0001" or less
Order No.
Resolution
Measuring range Throat depth Contact point and anvil
Accuracy
Measuring force
547-300S
547-320S
547-400S
.0005"/0.01mm
.0005"/0.01mm
.00005"/0.001mm
0~.4"/0~10mm
30mm
0~.4"/0~10mm 120mm
0~.47"/0~12mm 21mm
±.001"
±.001"
±.0001"
1.5N or less
1.5N or less
3.5N or less
Metric
ISO/JIS Type
Parallelism of contact point
and anvil
ø10mm flat
10µm or less
ø10mm flat
10µm or less
ø6.3mm flat (carbide tipped) 3µm or less
Order No.
Resolution
Measuring range Throat depth Contact point and anvil
Accuracy
Measuring force
547-301
547-321
547-401
0.01mm
0.01mm
0.001mm
0~10mm
0~10mm
0~12mm
±20µm
±20µm
± 3µm
1.5N or less
1.5N or less
3.5N or less
30mm
120mm
21mm
Note) 1. Changing the contact point requires total adjustment, including the main display unit. Contact Mitutoyo for advice.
2. The accuracy specification does not include the quantizing error of ±1 count.
3. Left-handed models can be supplied to special order.
8
ABS Digimatic Lens Meter
Unit: mm
Flat contact
point
Contact
point
9.3
Spherical contact Flat contact
point
point
Anvil
Concave lens
Anvil
Convex lens
Sø4 spherical
contact point
Standard accessory
Anvil adjustment:
12 mm
SR3
30
SR3
ø6
ø4.8
9.3
SR2
Anvil
Moon lens
30.3
9.3
• Designed for measuring the thickness of concavo-convex lenses and flat objects
• The thickness of flat objects can be measured by replacing the anvil.
• Includes a spherical contact point.
547-312S
ANSI/AGD Type
Order No.
Resolution
547-312S
.0005"/0.01mm 0~.4"/0~10mm 30mm
Metric
Measuring range Throat depth
SR2
Anvil adjustment
12mm
30
ø6
ø4.8
30
Inch/Metric
(Throat depth)
85
Accuracy
Measuring force
Anvil displacement: 12 mm
SR3
±.001" or less 85
1.5N or less
ISO/JIS Type
Order No.
Resolution
Measuring range Throat depth
Anvil adjustment
Accuracy
Measuring force
547-313
0.01mm
0~10mm
12mm
±20µm or less
1.5N or less
30mm
Note) The accuracy specification does not include the quantizing error of ±1 count. Left-handed models can be supplied to special order.
ABS Digimatic Pipe Gage
Unit: mm
• Designed for measuring the thickness of pipes and curved boards
ø3
ø3
Contact
point
Tip: ø3.5
Effective
throat
depth
20
21
Inch/Metric
85
ANSI/AGD Type
Order No.
Resolution
547-361S
.0005"/0.01mm 0~.4"/0~10mm 20mm
Measuring range Throat depth
Minimum inside
diameter of pipe
ø3.5mm
Accuracy
Measuring force
±.001" or less
1.5N or less
ø3
547-361S
Anvil
Metric
ISO/JIS Type
Order No.
Resolution
Measuring range Throat depth
547-360
0.01mm
0~10mm
20mm
Minimum inside
diameter of pipe
ø3.5mm
アンビル 有効差し
球ø3.5 込み深さ
Accuracy
21
Measuring
force
±20µm or less
1.5N or less
Note) 1. Changing the contact point requires total adjustment, including the main display unit. Contact Mitutoyo for advice.
2. The accuracy specification does not include the quantizing error of ±1 count.
3. Left-handed models can be supplied to special order.
9
Application Products
Unit: mm
ABS Digimatic Groove Gage
• Best suited for measuring the depth of narrow grooves on
cylindrical workpieces
• The contact point and measuring face of the anvil are
1mm thick blades.
Inch/Metric
66
30.3
(Throat depth)
85
ANSI/AGD Type
Resolution
547-316S
.0005"/0.01mm
Measuring range Throat
depth
0~4"/0~10mm 30mm
ontact point and anvil Accuracy
C
Measuring force
dimensions (W × D)
6.5mm x 1mm
±.001" or less 1.5N or less
30
ø6.5
55
Order No.
Metric
1
Contact
point
Anvil
ISO/JIS Type
Contact point and anvil Accuracy
Measuring range Throat
Measuring force
depth
dimensions (W × D) 1
85
547-315
0.01mm
0~10mm
30mm
6.5mm x 1mm
±20µm or less 1.5N or less
Note) 1. Changing the contact point requires total adjustment, including the main display unit. Contact Mitutoyo for advice.
2. The accuracy specification does not include the quantizing error of ±1 count.
3. Left-handed models can be supplied to special order.
Order No.
547-316S
Resolution
Unit: mm
ø59
ABS Digimatic Depth Gage
(67)
(105)
• Suitable for measuring the depth of holes, narrow grooves, and steps.
• The lifting lever can be used either on the left or right sides.
17
(10)
(35)
(11)
ø16
547-218S
Inch/Metric
Order No.
547-217S
547-218S
547-257S
547-258S
Metric
Order No.
ANSI/AGD Type
Measuring
range
.0005"/0.01mm 0~8"
.0005"/0.01mm 0~8"
.00005"/0.001mm 0~8"
.00005"/0.001mm 0~8"
Resolution
Stroke Accuracy
.5"
.5"
.5"
.5"
±.001" or less
±.001" or less
±.0002" or less
±.0002" or less
Measuring
force
1.5N or less
1.5N or less
1.5N or less
1.5N or less
Base
Length
2.5"
4"
2.5"
4"
Width
.63"
.63"
.63"
.63"
Contact point: Carbldetipped ball
Flatness
.0002" or less
.0002" or less
21JAZA242
.00008" or less
.00008" or less
ø5
ø6
SR
1.5
A
Extension rods
4 pcs. (.5",1",2",4")
4 pcs. (.5",1",2",4")
4 pcs. (.5",1",2",4")
4 pcs. (.5",1",2",4")
ISO/JIS Type
Resolution
Measuring Stroke
range
Accuracy
547-211
0.01mm
±20µm
547-212
0~200mm 12mm
547-251
0.001mm
±5µm
547-252
Note) The accuracy specification does not include the quantizing error of ±1 count.
Base
Length
Width Flatness
63.5mm
1.5N or less
5µm or less
101.6mm
16mm
63.5mm
1.5N or less
2µm or less
101.6mm
Measuring
force
10
Contact point: CarbldeExtension rods
tipped ball
21JAA224
5 pcs.
(10, 20, 30, 30, 100mm)
Unit: mm
40
ABS Digimatic Bench Gage
ø59
92
60
5
Support plate
547-066S
Inch/Metric
Order No.
547-066S
Metric
ø20
55
Effective throat depth
ø8
ø6.3
10
45
• The support plate allows easy reading by tilting the anvil.
• Carbide measuring faces (for the contact point and anvil)
• The lifting lever can be used either on the left or right sides.
Flat anvil
ANSI/AGD Type
Indicator stroke
.5"
Resolution
Remarks (contact point) Effective throat depth Workpiece height
.0005"/0.01mm .248" DIA flat type
.59"
1"
Accuracy
±.001" or less
Measuring force
1.5N or less
Resolution
0.01mm
Accuracy
Measuring force
±20µm or less 1.5N or less
ISO/JIS Type
Order No.
547-064
Indicator stroke
12mm
Workpiece height
ø20mm
Effective throat depth Anvil adjustment
15mm
13mm
Note) The accuracy specification does not include the quantizing error of ±1 count.
ABS Digimatic Upright Gage
• Best suited for inspection of small parts at a site
• Carbide ball contact point
• The lifting lever that is a standard accessory for No. 547-054,
547-034S can be used either on the left or right sides.
Anvil
(hardened
steel)
Effective measuring range
Unit: mm
SR
35
12
115
1.5
ø40
547-035S
Inch/Metric
Order No.
547-034S
547-033S
547-035S
Metric
Order No.
547-054
547-053
547-055
Center of anvil
1
Measuring depth 45 20
95
Center of
contact point
60
ANSI/AGD Type
Resolution
.0005"/0.01mm
.00005"/0.001mm
.00005"/0.001mm
Measuring range
.5"
.5"
.5"
Anvil
1.57" DIA steel type
1.97" DIA ceramic type
1.57" DIA steel type
Workpiece height
1.2"
1.2"
1.2"
Accuracy
±.001" or less
±.0001" or less
±.0001" or less
Measuring range
12.7mm
12.7mm
12.7mm
Anvil
ø40mm (steel type)
ø50mm (ceramic type)
ø40mm (steel type)
Workpiece height
Accuracy
±20µm or less
± 3µm or less
± 3µm or less
Measuring force
1.5N or less
ISO/JIS Type
Resolution
0.01mm
0.001mm
0.001mm
30mm
Measuring force
1.5N or less
Note) 1. The lifting lever (part No. 21EZA198) is a standard accessory for 547-054.
2. The lifting lever (part No. 21EZA199) is a standard accessory for 547-034S.
3. The lifting cable (part No. 540774) is a standard accessory for 547-055, 547-033S, 547-035S.
4. The accuracy specification does not include the quantizing error of ±1 count.
• The ABS (ABSOLUTE) scale used in these products is a capacitance type absolute encoder. Its patent has been registered in Japan, the U.S., the U.K., Germany, and China.
11
Export permission by the Japanese government may
be required for exporting our products according to
the Foreign Exchange and Foreign Trade Law. Please
consult our sales office near you before you export
our products or you offer technical information to a
nonresident.
One Number to Serve You Better
1-888-MITUTOYO (1-888-648-8869)
Aurora, Illinois
(Corporate Headquarters)
Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this printed matter as
well as other technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs. The
stated standards, similar technical regulations, descriptions and illustrations of the products were valid at the time of printing. In addition, the latest applicable
version of our General Trading Conditions will apply. Only quotations submitted by ourselves may be regarded as definitive.
Mitutoyo products are subject to US Export Administration Regulations (EAR). Re-export or relocation of Mitutoyo products may require prior approval by an
appropriate governing authority.
Trademarks and Registrations
Designations used by companies to distinguish their products are often claimed as trademarks. In all instances where Mitutoyo America Corporation is aware
of a claim, the product names appear in initial capital or all capital letters. The appropriate companies should be contacted for more complete trademark and
registration information.
We reserve the right to change specifications and prices without notice.
© 2009 Mitutoyo America Corporation, Aurora IL
0409-09 Printed in USA, June 2009
Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this pamphlet, as well as other
technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs, dimensions and weights.
Westford, Massachusetts
Huntersville, North Carolina
Mason, Ohio
Plymouth, Michigan
Mitutoyo
Corporation
City of Industry,
California
20-1, Sakado 1-chome,
Takatsu-ku, Kawasaki-shi,
Kanagawa 213-8533, Japan
T +81 (0) 44 813-8230
F +81 (0) 44 813-8231
http://www.mitutoyo.co.jp