LabDAQ® Laboratory Information System

Transcription

LabDAQ® Laboratory Information System
ADVERTISEMENT
LabDAQ® Laboratory Information System (LIS)
Features
LabDAQ Laboratory Information System
(LIS) offers complete system integration
with bidirectional interfaces with EMR,
HIS, practice management systems and
reference laboratories. Antek’s experience
ensures smooth and timely integration
of your software systems. The new HL7
Reconciler provides LabDAQ users with an
advanced utility for controlling incoming
patient information from an HL7 reference
laboratory interface.
Benefits
LabDAQ LIS improves workflow in the laboratory through robust analyzer interfaces,
Web-based ordering and results retrieval, and
expanded client-defined rules-based technology, which assists in decision-making through
the testing process. Scanning and storage of
images and advanced QC, which includes scheduled QC and the ability to hold results if QC
has not been run or is not acceptable, are also
available.
Antek HealthWare LLC
(800) 359-0911 ext. 3
www.AntekHealthWare.com
BINDAZYME Human Anti-Gliadin MGP IgG and IgA EIA Kits
Features
Conventional gliadin ELISA methods use
crude gliadin antigen and have shown limited sensitivity and specificity for the diagnosis of celiac disease. BINDAZYME Human
Anti-Gliadin MGP IgG and IgA EIA Kits use
a modified gliadin peptide that is deamidated by the enzyme tissues transglutaminase (tTg) enhancing the immunogenicity
of gliadin.
Benefits
BINDAZYME Anti-Gliadin MGP provides superior sensitivity, specificity, and diagnostic accuracy over conventional methods. Production of
gliadin antibodies early in the disease makes
BINDAZYME MGP a useful marker for early
detection. Other benefits of MGP include monitoring celiac disease activity and compliance to
a gluten-free diet. Binding Site automation protocols are available.
Binding Site Inc
(858) 453-9177
www.bindingsite.co.uk/antigliadiniggigacomb-402.asp
BinaxNOW® Influenza A & B test
Features
Self-contained CLIA-Waived point-of-care
test. What you need to perform the test is
included in the kits. No mixing of samples
or extra up front time needed for manipulation. Calibrated pipettes and a Flu A/B
positive control swab and negative control
swab. QC requirements of once per shipment. Shelf life of up to 24 months from
date of manufacture.
Benefits
Detection of Flu (influenza A & B). Test results
appear in 15 minutes, showing a positive or
negative line after the allotted read time.
When the BinaxNOW® Influenza A & B is used
in combination with the BinaxNOW® RSV test,
one sample can be used to perform Influenza A,
Influenza B and RSV for three total test results.
Inverness Medical
(877) 546-8633
www.invernessmedicalpd.com
26
May 2009 | clpmag.com
26-27_FABs.indd
26
5/1/09
9:43:48 AM
ADVERTISEMENT
BinaxNOW® Streptococcus pneumoniae
Features
Self-contained CLIA-Waived point-of-care
test. 93% overall accuracy for the detection
of pneumococcal pneumonia. Compliance
with the new IDSA/ATS CAP Guidelines (urinary antigen test recommendation). Easy to
use, easy to manage and train; minimizes
operator error. Room-temperature storage—doesn’t take up valuable refrigerator
space.
StatSpin Express 4
Features
The StatSpin Express 4 high-speed horizontal centrifuge provides faster turnaround
time and greater productivity for your
”Lean” laboratory. Place it next to any STAT
analyzer. Serum or plasma is ready in just
3 minutes. Provides rapid separation of gel
tubes with a flat gel barrier. Only three
settings minimizes operator error. It holds
eight tubes from 1.5 to 10 mL. It comes
with a full 2-year warranty and is CE and UL
marked.
Benefits
Detection of S. pneumoniae for bacterial meningitis and pneumonia. Test results appear in
15 minutes, can shorten patient wait time.
Rapid results mean targeted treatment plans,
improved infection control, and reduced hospital costs.
Inverness Medical
(877) 546-8633
www.invernessmedicalpd.com
Benefits
Samples can be processed as they arrive in the
lab; no need for batching, no unproductive time
spent waiting for the centrifuge ... you’ll have
results in minutes. Now you can process as many
as eight samples at once for higher throughput.
In just 3 minutes, the Express 4 can produce
serum or plasma from tubes with or without gel
equal to tubes spun for 10 to 15 minutes in conventional clinical centrifuges. It can replace large
bench or floortop models with its small size.
Iris Sample Processing
(800) 782-8774
www.proiris.com
MEDICA® Pro Water Systems for Clinical Analyzers
The MEDICA® Pro Water System produces CLRW quality water for the Clinical Analyzers in your lab.
Features
MEDICA® Pro has a special Protek pretreatment cartridge that minimizes chlorine and
chloramines and a deionization cartridge
with enhanced resin mix to reduce the
number of change-outs. It has leak detectors, alarms and an auto shut-down. It’s
easy to sanitize and can be supplied with
validation documentation
Benefits
MEDICA® Pro guarantees CLRW standard grade
water. All technologies are located within one
space-saving cabinet. Its deionization cartridge
system helps save on annual running costs. It
can be customized to your specific requirements, yet because it has a unique integral reservoir, it’s easy to install and start up—just plug
and start.
Siemens Water Technologies
(800) 875-7873, ext 5000
www.siemens.com/water
Thermo Scientific SlideMate™ Slide Labeler
Features
The Thermo Scientific SlideMate™ is an ondemand slide printer with a small footprint
about the size of a toaster. SlideMate prints
directly onto the slide with a chemical-resistant print media that dries immediately.
SlideMate allows data to be input from a
bar code scanner, keyboard, LIS system or
LabWriter software.
Benefits
SlideMate fits next to the microtome and prints
slides just as they are needed. The printed text
will not come off the slide when exposed to the
harsh chemicals used in the histology laboratory process. SlideMate can be adapted into any
laboratory’s desired on-demand slide-labeling
process.
Thermo Fisher Scientific
(800) 522-7270
www.thermo.com/pathology
clpmag.com | May 2009
26-27_FABs.indd
27
27
5/1/09
9:14:30 AM