Drucker Centrifuge Features Guide

Transcription

Drucker Centrifuge Features Guide
Drucker Centrifuge Features Guide
Model 853VES
Model 755VES
Model 642E
Providing Quality Centrifuges since 1932
Centrifuge
Model
614B
642B
642E
642VES
642VFD
653ES
653V-12
653V-20
755-12
755-24
755V-12
755V-24
755VES
756
842HS
842VES
842VES-PERF
853VES
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
O
O
S
O
O
O
O
O
O
S
S
S
S
S
S
S
S
S
S
S
O
S
S
O
Standard feature with model
S
6
S
O
S
O
S
12
S
O
48
S
Microtube
(16)
S
Microhematocrit
(16)
O
Microplate
O
S
6
S
16
O
S
20
S
S
S
24
S
S
S
S
S
S
S
S
O
S
S
S
S
S
S
S
S
S
S
O
S
S
S
S
S
S
S
O
S
S
O
S
O
O
O
O
Rotor Angle: The centrifuge rotor can spin tubes horizontally, using
Drucker’s patented technology, or at a fixed angle.
Rotor Places: The number of spaces for tube holders/carriers in the rotor.
Tube Capacity: The total number of tubes that can be spun using the
centrifuge and its standard and optional tube holders/carriers.
Tube Holder/Carrier Type: The types of tube holders and carriers that
are standard and available as an option for the centrifuge.
Time Range: The range of time (in minutes) to which the centrifuge can be set.
S
O
100 mm Carrier
(2-Place)
O
50 mL Holder
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Mechanical
3,800
3,200 (Standard);
3,900 (Optional)
3,150
2,000
1,425 (Standard);
1,860 (Optional)
1,600
1,600
1,200
Max Force
(g)
9 H x 11 W x 12.5 D
8.5 H x 11 W x 12.5 D
8.5 H x 11 W x 12.5 D
8.5 H x 11 W x 12.5 D
8.5 H x 11 W x 12.5 D
Size
(Inches)
18.5
Weight
(Lbs)
4,300
3,150 (Standard);
4,000 (Optional)
3,200
3,000 (Standard);
3,200 (Optional)
13,520
3,150
3,150
1,690 (Standard);
2,000 (Optional)
1,860
1,530 (Standard);
1,850 (Optional)
1,850
1,280
1,600
1,500
8.5 H x 12.5 W x 15.5 D
8.5 H x 12.5 W x 15.5 D
8 H x 11 W x 13.5 D
10.5 H x 14.5 W x 17 D
9 H x 14.5 W x 17 D
12 H x 14.5 W x 17 D
11 H x 14.5 W x 17 D
10 H x 14.5 W x 17 D
9 H x 14.5 W x 17 D
8.5 H x 12.5 W x 15.5 D
8.5 H x 12.5 W x 15.5 D
9 H x 12.5 W x 15 D
3,380
12,000
2,800 (Standard);
4,880 (Optional)
8.5 H x 12.5 W x 15.5 D
S
4,300
3,200
3,200
3,200
S
4,500 (Standard);
7,000 (Optional)
5,000
S
S
2,400
8.5 H x 12.5 W x 15.5 D
6,500
4,000
5,000
3,800
S
S
S
30
30
30
30
27
46
39
39
39
39
39
30
30
18.5
18.5
18.5
18.5
18.5
S
3,150
Max Speed
(RPM)
3,380
S
Digital
Timer Type
S
S
S
S
S
S
S
S
Electronic
Weight: Weight of the centrifuge in pounds.
Size: Dimensions of the centrifuge in inches.
Max Force: The maximum force (g) obtained by the centrifuge using
standard or optional rotors (as noted).
Max Speed: The maximum speed (RPM) obtained by the centrifuge
using standard or optional rotors (as noted).
Timer Type: The timer can either be set mechanically (using a dial),
electronically (by pushing a button with no digital display), or digitally
(with display).
S
1-99 Minutes
Time
Range
S
S
O
S
S
1-30 Minutes
S
100 mm Carrier
(4-Place)
Tube Holder/Carrier Type
S
125 mm Holder
S
100 mm Holder
S
S
75 mm Holder
O
O
48
Tube Capacity
S
S
O
S
S
S
S
S
S
12
Speed: Defines whether the centrifuge has a single set speed or a range
that is selectable by the user.
O
S
S
O
O
S
S
S
S
S
O
2
Rotor Places
O
S
20
Glossary of Terms
16
Rotor
Angle
S
S
S
S
S
S
S
S
S
S
S
S
S
S
2
S
S
Fixed
Speed
S
S
S
S
S
Horizontal
Optional feature with model
S
Variable
O
853VES-PERF
Single
Since 1932, The Drucker Company has been developing
quality, high performance centrifuges. At Drucker, we take pride
in our many innovations, including the world’s first affordable
horizontal rotor. These innovations have allowed us to offer many
different models of centrifuges and numerous accessories, all to
better customize the experience for our customers.
This document is intended to serve as a handy reference tool to
Providing
Quality
Centrifuges
Since 1932
compare some of the features available with Drucker Centrifuges.
It is by no means a comprehensive list of all features, but instead
should provide basic information to provide assistance in selecting
the centrifuge that is right for the user’s needs.
For further details on selecting Drucker centrifuges, please
consult any of our online resources at www.druckercompany.com
or contact our centrifuge experts at [email protected].
www.druckercompany.com
Form 280 Rev. B
168 Bradford Drive
Port Matilda, PA 16870 EE. UU.
+1-814-692-7661
www.druckercompany.com

Similar documents

Service Manual - Drucker Diagnostics

Service Manual - Drucker Diagnostics f) Slide the board onto the studs g) Install four plastic washers onto the studs. h) Important: over tightening the PCB nuts will cause malfunction – Each nut sets the height of a separate control ...

More information

model 642ves - Drucker Diagnostics

model 642ves - Drucker Diagnostics See the next page for a description of optional accessories.

More information