ConVaultPlus STI SP001Compliant

Transcription

ConVaultPlus STI SP001Compliant
ConVault Plus
STI SP001Compliant
The Only Above Ground Fuel Storage Tank with
UL 752 Level 8 Ballistic Rating
Fire Protection
STI SP001 Compliant
EPA Compliant
Impact Resistant
ConVault’s resistance to
blast, projectile, and vehicle
impact, exceeds U. L. 2085
specification.
ConVault is compliant
with EPA regulations, Spill
Prevention, Containment,
and Countermeasures
plans.
ConVault’s unique double wall
steel tank system allows for testing and inspection compliant
with STI SP001.
Seamless, six-inch reinforced
concrete provides two-hour
fire protection as per U. L. 2085
specification.
Multiple Size Options
Leak Containment
Primary Steel Tank
Primary steel tank is isolated
from the concrete encasement
to assure corrosion protection.
Thermal Protection
ConVault’s monolithic concrete
enclosure and insulation layers
provide thermal protection.
Secondary Steel Tank
Second steel tank is isolated
from the Primary steel tank
allowing for SP001 Testing
Compliance.
ConVault provides versatile
storage solutions with tank
sizes ranging from 125 to
12,000 gallons.
A high performance, high
density polyethylene membrane encloses the primary
and secondary tanks and
provides leak containment.
Above Ground Liquid Storage Solutions
www.convault.com
888-965-3227
ConVault Plus
Now With a Double Wall Steel Tank to
Allow For Easy On-Site Testing
ConVault Options
Feature/Benefit
ConVault
ConVault Plus
Double Wall Steel Tank
SP 001 Test Compliant
Primary Steel Tank
Secondary Containment
Impact Resistant0+
Multiple Size Options
EPA Compliant
Vehicle0
Ballistics +
Thermal Protection
Fire Protection*
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
ASTM F 2656 - 07 Standard
Underwriters Labratory UL 752 Level 8 Ballistics Standard
*
4 Hour Rating ASTM E-1529
0
+
ConVault Plus Benefits
• STI SP001 Compliant - Convault’s unique double wall steel
tank system allows for testing and inspection compliant with
STI SP001.
• Manufactured to the rigid standards of the Oldcastle
quality control program at Oldcastle facilities around
the country.
• Double Wall Steel Tank - Primary and Secondary tanks offer
increased protection and allow for testing of interstitial space.
• Engineering - Every ConVault tank is designed and
engineered to meet or exceed industry requirements
for above ground fuel storage.
• UL listed - ConVault AST is listed in accordance with ULC
142.16, ULC 142.23 and UL Standard 2085 Insulated/Secondary
Containment for Above ground Storage Tanks/Protected Type.
• Meets Safety Regulations - ConVault tanks meet all safety
requirements for primary and secondary containment, leak
monitoring, spill containment and overfill protection.
• Environmentally Secure - With multiple layers of
containment surrounded by 6” of steel reinforced
concrete, ConVault is designed to protect.
• LEED - Manufactured locally with recycled material.
for potential LEED credits.