Maxseal Solenoid Valves

Transcription

Maxseal Solenoid Valves
Maxseal Solenoid Valves
Up to 4"
Maxseal Technology
from FCX Thompson Valves.
An Industry
Standard Evolved
from an Original
Concept.
• Original, direct-acting design specified throughout
industry for process control and related
instrumentation.
• Exacting standards in chemical, gas turbine, naval,
nuclear power, offshore, petrochemical and
pharmaceutical applications.
• 40 year track record of effective safety in hazardous
service duties.
• 40 years experience in North Sea environments.
• A worldwide market leader for proven performance
and reliability.
Approvals and
Certification.
Maxseal solenoid valves are designed for use in
hazardous areas and conform to BASEEFA / SIRA and
European CENELEC specifications.
Factory Mutual Research Corporation Approved.
Maxseal valves comply with the following EC directives
and are therefore entitled to bear the CE mark.
89/392/EEC
89/336/EEC as amended by
92/31/EEC and 93/68/EEC
72/23/EEC as amended by
93/68/EEC
ATEX Directive
94/9/EC
PHOTOGRAPH COURTESY OF ALSTOM POWER UK LTD
Machinery Directive
Electromagnetic Compatibility Directive
(EMCD)
Low Voltage Directive (LVD)
2
We are here to help!
When you've browsed this overview,
talk to us about the best solution
for your system.
The Industry Standard Maxseal Solenoid Valve.
Model Shown:
ICO4S 1/4" Stainless Steel EEx d Valve.
Ingress protection
to IP66.
Position feedback
(larger models).
Class “H”
insulation.
DC coils with
suppression diodes.
Low power
direct acting lift.
High-thrust
return spring.
Threaded or
flanged process
connections
(larger models).
2/2, 3/2 and
5/2 port
configurations.
Low-friction
poppet design.
Seal/body options
0-207 bar (0-3000 psi)
gases and liquids.
Full flow capability.
Manual and
tamper-proof
reset options.
• Proven reliability of the original direct-acting
solenoid valve design.
• Certification and approvals for use in
hazardous areas.
• Choice of materials to suit process requirements.
• Compact and lightweight unit.
We are here to help!
www.fcx-thompson-valves.com
3
The Power to Perform.
FCX Thompson Valves is part of
the FCX Flow Control division of
Charles Baynes plc, a leading
supplier of specialist flow control
products with a network of global
resources.
PHOTOGRAPH COURTESY OF ALSTOM POWER UK LTD
FCX Thompson Valves packaged and component
solutions are specified worldwide for their high
technical added value and fitness for purpose in
exacting control and instrumentation applications.
A Tradition of
Integrity.
Maxseal solenoid valves produced by FCX Thompson
Valves consistently set rigorous standards for
process management in the most demanding
environments: aerospace, defense, gas turbine,
mining, nuclear power, offshore and petrochemical
industries.
www.fcx-thompson-valves.c
We are here to help!
[email protected]
+44 1202 697521
Safe, Reliable and Cost-Effective
Solutions.
Maxseal solenoid valves from FCX Thompson Valves
are market leaders. In critical duties such as oil and
gas, they perform on most offshore production
platforms in the North Sea, as well as in all major
onshore terminals.
Gas t
Absorption equipment
Water treatment
Absorption equipm
Fuel systems
Gas turbines, generators and compressors
Air condit
Pipeline shut-off Water treatment
Fire safety and deluge systems
Fire safety and delug
Contents.
Page
Maxseal Technology from FCX Thompson Valves
2
Technical Information
Hazardous area
Model
Connection size
Operating pressure, bar (psi)
Zone 0
ICO2S
1/4"
Main valve
Pilot valve
Zone 1
ICO4D
ICO4S
ICO4D
ICO4S
SOV 1-2
1/4"
NPT
NPT
1/2" NPT
1/2" NPT
1/2" - 3/4" NPT
1/2" - 3/4" flanged
1" - 2" NPT
1" - 3" flanged
0
0
0
0
0
POICO4
1/4"
NPT
Dual shuttle valve
1/4"
NPT
POV
1/2"
- 2" NPT
- 4" flanged
Main valve
Pilot valve
Main valve
Pilot valve
Main valve
Pilot valve
1/4"
SOV 3-6
Zones 1 and 2
1/2"
-
20
20
20
20
20
(0
(0
(0
(0
(0
-
0 - 20 (0 - 290)
2 - 7 (29 - 101.5)
8
10
12
14
16
0 - 20 (0 - 290)
18
0
2
0
0
0
2
NPT
1" - 2" NPT
1" - 4" flanged
0 - 20 (0 - 290)
0 - 20 (0 - 290)
As SOV 1-6, Zone 2
NPT
As SOV 1-6,
Main valve
Pilot signal
Main valve
Pilot signal
ICO4N
SOV 1-6
Unclassified
SOV 1-6 (weatherproof)
AOV
1/4"
AOV
1/2"
- 2" NPT
- 4" flanged
6
290)
290)
290)
290)
290)
1/4"
Zone 2
1/2"
com
NPT
-
20
10
10
10
20
10
Zone 2
0 - 20
2 - 10
0 - 20
2 - 10
(0 - 290)
(29 - 145)
(0 - 145)
(0 - 145)
(0 - 290)
(29 - 145)
20
22
24
26
28
(0 - 290)
(29 - 145)
(0 - 290)
(29 - 145)
28
30
32
Optional Valve Features
Automatic
Lever Manual Reset
Lever Manual Override
Automatic Latching Lever
Tamperproof Manual Reset
34
34
34
34
34
Special Valve Features
Indicating Switches
High Temperature Spacer
Horizontal Mounting
35
35
35
Hazardous Area Guidelines
Intrinsic Safety
Installation Guidelines
Coding System
36
37
38
Valve Flow Characteristics
40
Valve Flow Performance Charts
1. Air Flow, ICO4 1/4", Low Pressure
2. Air Flow, ICO4 1/2", Low Pressure
3. Liquid Flow, ICO4 1/4", Low Pressure
4. Liquid Flow, ICO4 1/4", High Pressure
5. Flow Test, ICO4 1/4"
6. Flow Test, ICO4 1/2"
7. Flow Test, ICO4 1/2"
43
43
44
44
45
46
46
Conversion Chart
47
turbines, generators and compressors
Pneumatic cylinders
Pipeline shut-off
Emergency shutdown
Absorption Emergency shutdown systems Pipeline shut-off
ment
s
Absorption equipment
tioners and Air
dryers
conditioners and dryers
Pneumatic cylinders
Fuel systems
ge systems
Fuel systems
Air conditioners and dryers
Pneumatic cylinders
Gas turbines, generators and compressors
Hazardous Area
Zone 0
Maxseal
Instrument Changeover and Process
Control Valve for Hazardous Areas
EEx ia
Model ICO2S 1/4" - 2"
Certification
Description
II 1G
SIRA / CENELEC approved
EEx ia IIC T6 Ta (-40ºC to +64ºC)
Complies with EN 50014:1997 (incl. amendments A1 and A2), EN 50020:1994
and EN 50284:1999
Complies with ATEX Directive 94/9/EC
Complies to Electrical Safety Standard IEC 1010
Assessed compliant to Pressure Equipment Directive 97/23/EC
FM approved to I.S. Class I Division 1 Groups A.B.C.D.
A pilot operated solenoid
valve certified for use with
hazardous gases.
2-port, EO
3-port
5-port
A
C
E
A
C
B
D
B
Standard Features
Port thread (main body)
Port configuration
Operating pressure
Main valve
Pilot valve
1/4"
NPT
0 - 20 bar(g) (0 - 290 psi)
2 - 7 bar(g) (29 - 101.5 psi)
Pilot assisted
Stainless steel BS EN 10088
Liquids and gases
2 - 7 bar (29 - 101.5 psi)
clean and dry instrument
air or inert gas
Seat / Seal material
High nitrile (Buna N)
Operating voltage
24V DC; 0.5W at
20ºC (68ºF) through barrier
M20 x 1.5 mm ISO (F) /
NPT
1/4"
6
Port thread
Paint finish
Unpainted
Coil housing material
Stainless steel
BS 3146 ANC.4 BFC.316
Weight
3-port version: 3 kg (6.6 lb)
Cv value
0.8 (Kv 0.69)
1/4"
1/2"
3/2 Uni
Valve material
Conduit / Signal entry
A
B
B
Options
Actuation method
Media
Main valve
Pilot valve
A
2-port, EC
- 2" BSPP / BSPT
- 2" NPT
Port configuration
5/2 Uni; 2/2 EO; 2/2 EC
Actuation method
Autolatch, lever manual
reset (LMR), lever manual
override (LMO),
tamperproof manual reset
(see "Optional Valve
Features")
Valve material
Brass BS EN 12163: 1998
Seat / Seal material
Viton®, nylon 66
(high pressure seat only)
Alternative materials
available on request
Conduit / Signal entry
1/2"
CV value (main valve)
1/4" model
1/2"
- 2" models
NPT
0 - 50 bar(g) (0 - 725 psi)
= 0.6 (Kv = 0.5)
0 - 103/207 bar(g)
(0 - 1494/3000 psi) = 0.28
(Kv = 0.24)
Please contact us
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
Hazardous Area
Zone 0
Maxseal
Instrument Changeover and Process Control Valve for Hazardous Areas
EEx ia
ICO2S 1/4" - 2"
Technical Specification
Protection
Ingress IP66 / X8. NEMA 4X
Surge suppression diodes
Response times
(typical, dependent on coil size)
Pull-in < 150 ms
Drop-out < 80 ms
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Operating pressure ranges (main valve)
1/4" model
0 - 20 bar(g)
0 - 50 bar(g)
0 - 103 bar(g)
0 - 207 bar(g)
1/2" - 2" models
Please contact
(0
(0
(0
(0
us
-
Dimensions in mm (inches)
290 psi) (standard)
725 psi) (option)
1494 psi) (option)
3000 psi) (option)
A typical basic installation would comprise a 24V DC power
supply, control switch or relay, and an EEx.ia 300Ω 28V barrier.
(3/2 Uni 1/4" configuration illustrated)
Pilot
vent
port
22.2 (0.87)
ø 56 (2.20)
118 (4.65)
22.2
(0.87)
21
(0.83)
11 (0.43)
45 (1.77)
Pilot
inlet
port
124.5 (4.90)
170 (6.69)
2 x M6
mounting
studs
202 (7.95)
47 (1.85)
M20 x 1.5 mm ISO
conduit entry
ø 58 (2.28)
Port A
Inlet
Port B
Outlet
Port C
Exhaust
ø 50.8 (2)
For your convenience,
Operation and Maintenance
instructions are included
with each valve.
7
Hazardous Area
Zone 1
Maxseal
Instrument Changeover and Process
Control Valve for Hazardous Areas
EEx d
Model ICO4D 1/4"
Certification
Description
II 2G
EECS (BASEEFA) / SIRA CENELEC approved
EEx d IIC T6 (Ta = -60ºC to +40ºC) or
EEx d IIC T4 (Ta = -60ºC to +90ºC)
Complies with BS 5501: Part 5:1977, EN 50014:1977 (amendments 1 and 2)
and EN 50018:1994
Complies with ATEX Directive 94/9/EC
A direct-acting solenoid
valve certified for hazardous
area use as well as general
air and gas purposes in the
offshore and petrochemical
industries.
2-port, EO
3-port
5-port
A
C
E
A
C
B
D
2-port, EC
B
Standard Features
Options
Port thread
1/4"
Port configuration
NPT
Port thread
1/4"
3/2 Uni
Port configuration
5/2 Uni; 2/2 EO; 2/2 EC
Operating pressure
0 - 20 bar(g) (0 - 290 psi)
Actuation method
Actuation method
Automatic
Valve material
Stainless steel
BS EN 10088
Seat / Seal material
High nitrile (Buna N)
Autolatch, lever manual
reset (LMR), lever manual
override (LMO),
tamperproof manual reset
(see "Optional Valve
Features")
Operating voltage
24V DC; 4.5W
at 20ºC (68ºF)
Valve material
Brass BS EN 12163: 1998
Seat / Seal material
Conduit / Signal entry
M20 x 1.5 mm ISO (F)
Paint finish
Standard (green) 40 µm
Viton®, nylon 66
(high pressure seat only)
Alternative materials
available on request
Coil housing material
Cast iron
BS EN 1561: 1997
Operating voltages
DC: 12, 24, 48, 110, 125,
240
AC: 24, 50, 110, 240, 440
Conduit / Signal entry
1/2"
Paint
Epoxy (light grey) 150 µm
CV value
0 - 50 bar(g) (0 - 725 psi)
= 0.6 (Kv = 0.5)
0 - 103/207 bar(g)
(0 - 1494/3000 psi) = 0.28
(Kv = 0.24)
Weight
3-port version: 5 kg (11 lb)
Cv value
0.8 (Kv 0.69)
BSPP; 1/4" BSPT
NPT, 13.5 PG
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
8
Hazardous Area
Zone 1
Maxseal
Instrument Changeover and Process Control Valve for Hazardous Areas
EEx d
ICO4D 1/4"
Technical Specification
Protection
Ingress IP65 - IP68
Surge suppression diodes
Response times
(typical, dependent on coil size)
Pull-in < 150 ms
Drop-out < 80 ms
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Operating pressure ranges
0
0
0
0
-
20 bar(g)
50 bar(g)
103 bar(g)
207 bar(g)
(0
(0
(0
(0
-
290 psi) (standard)
725 psi) (option)
1494 psi) (option)
3000 psi) (option)
Dimensions in mm (inches)
(3/2 Uni configuration illustrated)
55 (2.16)
57 (2.24)
52 (2.04)
54 (2.12)
M20 x 1.5 mm ISO
conduit entry
54 (2.12)
22
(0.86)
20 (0.78)
30 (1.18)
ø 56 (2.20)
85 (3.34)
62 (2.44)
21.5 22.2
(0.85) (0.87)
11 (0.43)
150 (5.90)
192 (7.56)
2 x M8
mounting studs
Port A
Inlet
Port B
Outlet
Port C
Exhaust
50.8 (2)
Remember that overhaul
kits and replacement coil
housing assemblies are
available.
9
Hazardous Area
Zone 1
Maxseal
Instrument Changeover and Process
Control Valve for Hazardous Areas
EEx d
Model ICO4S 1/4"
Certification
Description
II 2G
EECS (BASEEFA) / SIRA CENELEC approved
EEx d IIC T6 (Ta = -60ºC to +48ºC) or
EEx d IIC T4 (Ta = -60ºC to +90ºC)
Complies with EN 50014:1997 (amendments 1 and 2) and EN 50018:1994
Complies with ATEX Directive 94/9/EC
FM approved to Class I Division 1 Groups A. B. C. D
A direct-acting solenoid
valve certified for hazardous
area use as well as general
air and gas purposes in the
offshore and petrochemical
industries.
2-port, EO
3-port
5-port
A
C
E
A
C
B
D
B
Standard Features
Port thread
2-port, EC
Options
1/4"
NPT
Port thread
1/4"
BSPP; 1/4" BSPT
Port configuration
3/2 Uni
Port configuration
5/2 Uni; 2/2 EO; 2/2 EC
Operating pressure
0 - 20 bar(g) (0 - 290 psi)
Actuation method
Autolatch, lever manual
reset (LMR), lever manual
override (LMO),
tamperproof manual reset
(see "Optional Valve
Features")
Actuation method
Automatic
Valve material
Stainless steel
BS EN 10088
Seat / Seal material
High nitrile (Buna N)
Operating voltage
24V DC; 4.5W
at 20ºC (68ºF)
Conduit / Signal entry
M20 x 1.5 mm ISO (F)
Paint finish
Unpainted
Coil housing material
Stainless steel
BS 3146 ANC.4 BFC.316
Weight
3-port version: 5 kg (11 lb)
Cv value
0.8 (Kv 0.69)
Valve material
Brass BS EN 12163: 1998
Seat / Seal material
Viton®, nylon 66
(high pressure seat only)
Alternative materials
available on request
Operating voltages
DC: 12, 24, 48, 110, 125,
240
AC: 24, 50, 110, 240, 440
Conduit / Signal entry
1/2"
CV value
0 - 50 bar(g) (0 - 725 psi)
= 0.6 (Kv = 0.5)
0 - 103/207 bar(g)
(0 - 1494/3000 psi) = 0.28
(Kv = 0.24)
NPT, 13.5 PG
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
10
Hazardous Area
Zone 1
Maxseal
Instrument Changeover and Process Control Valve for Hazardous Areas
EEx d
ICO4S 1/4"
Technical Specification
Protection
Ingress IP65 / X8. NEMA 4X
Surge suppression diodes
Response times
(typical, dependent on coil size)
Pull-in < 150 ms
Drop-out < 80 ms
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Operating pressure ranges
0
0
0
0
-
20 bar(g)
50 bar(g)
103 bar(g)
207 bar(g)
(0
(0
(0
(0
-
290 psi) (standard)
725 psi) (option)
1494 psi) (option)
3000 psi) (option)
Dimensions in mm (inches)
(3/2 Uni configuration illustrated)
We recommend installing a
strainer or filter as close as
possible to valve inlet. While
protecting seating areas
from potential damage, this
helps maintain air quality Talk to us about filtration!
11
Hazardous Area
Zone 1
Maxseal
Instrument Changeover and Process
Control Valve for Hazardous Areas
EEx d
Model ICO4D 1/2"
Certification
Description
II 2G
EECS (BASEEFA) / SIRA CENELEC approved
EEx d IIC T6 (Ta = -60ºC to +40ºC) or
EEx d IIC T4 (Ta = -60ºC to +90ºC)
Complies with BS 5501: Part 5:1977, EN 50014:1977 (amendments 1 and 2)
and EN 50018:1994
Complies with ATEX Directive 94/9/EC
A direct-acting solenoid
valve certified for hazardous
area use as well as general
air and gas purposes in the
offshore and petrochemical
industries.
2-port, EO
3-port
A
C
2-port, EC
B
Standard Features
Options
Port thread
1/2"
Port configuration
NPT
Port thread
1/2"
BSPP; 1/2" BSPT
3/2 Uni
Port configuration
2/2 EO; 2/2 EC
Operating pressure
0 - 20 bar(g) (0 - 290 psi)
Actuation method
Actuation method
Automatic
Valve material
Stainless steel
BS EN 10088
Seat / Seal material
High nitrile (Buna N)
Autolatch, lever manual
reset (LMR), lever manual
override (LMO),
tamperproof manual reset
(see "Optional Valve
Features")
Operating voltage
24V DC; 15.2W
at 20ºC (68ºF)
Valve material
Brass BS EN 12163: 1998
Seat / Seal material
Conduit / Signal entry
M20 x 1.5 mm ISO (F)
Paint finish
Standard (green) 40 µm
Viton®
Alternative materials
available on request
Coil housing material
Cast iron
BS EN 1561: 1997
Operating voltages
DC: 12, 24, 48, 110, 125,
240
AC: 24, 50, 110, 240, 440
Weight
3-port version: 8 kg (17.6 lb)
Conduit / Signal entry
1/2"
Cv value
4.2 (Kv 3.61)
Paint
Epoxy (light grey) 150 µm
CV value
0 - 50 bar(g) (0 - 725 psi)
= 3.8 (Kv = 2.7)
non-universal
NPT, 13.5 PG
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
12
Hazardous Area
Zone 1
Maxseal
Instrument Changeover and Process Control Valve for Hazardous Areas
EEx d
ICO4D 1/2"
Technical Specification
Protection
Ingress IP65 - IP68
Surge suppression diodes
Response times
(typical, dependent on coil size)
Pull-in < 150 ms
Drop-out < 80 ms
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Operating pressure ranges
0 - 20 bar(g)
0 - 50 bar(g)
(0 - 290 psi) (standard)
(0 - 725 psi) non-universal (option)
Dimensions in mm (inches)
(3/2 Uni configuration illustrated)
54 (2.12)
22 (0.86)
57 (2.24)
20 (0.78)
36
(1.41)
ø 76 (3.0)
140 (5.51)
117 (4.60)
44 (1.73)
22 (0.86)
205 (8.07)
247 (9.72)
30 (1.18)
55 (2.16)
52 (2.04)
M20 x 1.5 mm ISO
conduit entry
54 (2.12)
2 x M8
mounting studs
Port A
Inlet
Port B
Outlet
Port C
Exhaust
70 (2.76)
For your convenience,
Operation and Maintenance
instructions are included
with each valve.
13
Hazardous Area
Zone 1
Maxseal
Instrument Changeover and Process
Control Valve for Hazardous Areas
EEx d
Model ICO4S 1/2"
Certification
Description
II 2G
EECS (BASEEFA) / SIRA CENELEC approved
EEx d IIC T6 (Ta = -60ºC to +48ºC) or
EEx d IIC T4 (Ta = -60ºC to +90ºC)
Complies with EN 50014:1997 (amendments 1 and 2) and EN 50018:1994
Complies with ATEX Directive 94/9/EC
FM approved to Class I Division 1 Groups A. B. C. D
A direct-acting solenoid
valve certified for hazardous
area use as well as general
air and gas purposes in the
offshore and petrochemical
industries.
2-port, EO
3-port
A
C
2-port, EC
B
Standard Features
Port thread
Options
1/2"
NPT
Port thread
1/2"
BSPP; 1/2" BSPT
Port configuration
3/2 Uni
Port configuration
2/2 EO; 2/2 EC
Operating pressure
0 - 20 bar(g) (0 - 290 psi)
Actuation method
Autolatch, lever manual
reset (LMR), lever manual
override (LMO),
tamperproof manual reset
(see "Optional Valve
Features")
Actuation method
Automatic
Valve material
Stainless steel
BS EN 10088
Seat / Seal material
High nitrile (Buna N)
Operating voltage
24V DC; 15.2W
at 20ºC (68ºF)
Conduit / Signal entry
M20 x 1.5 mm ISO (F)
Paint finish
Unpainted
Coil housing material
Stainless steel
BS 3146 ANC.4 BFC.316
Weight
3-port version: 8 kg (17.6 lb)
Cv value
4.2 (Kv 3.61)
Valve material
Brass BS EN 12163: 1998
Seat / Seal material
Viton®
Alternative materials
available on request
Operating voltages
DC: 12, 24, 48, 110, 125,
240
AC: 24, 50, 110, 240, 440
Conduit / Signal entry
1/2"
CV value
0 - 50 bar(g) (0 - 725 psi)
= 3.8 (Kv = 2.7)
non-universal
NPT, 13.5 PG
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
14
Hazardous Area
Zone 1
Maxseal
Instrument Changeover and Process Control Valve for Hazardous Areas
EEx d
ICO4S 1/2"
Technical Specification
Protection
Ingress IP65 / X8. NEMA 4X
Surge suppression diodes
Response times
(typical, dependent on coil size)
Pull-in < 150 ms
Drop-out < 80 ms
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Operating pressure ranges
0 - 20 bar(g)
0 - 50 bar(g)
(0 - 290 psi) (standard)
(0 - 725 psi) non-universal (option)
Dimensions in mm (inches)
(3/2 Uni configuration illustrated)
41 (1.61)
41 (1.61)
22
(0.86)
20
(0.78)
30 (1.18)
55 (2.16)
59 (2.32)
M20 x
1.5 mm ISO
conduit entry
36 (1.41)
ø 76 (3.0)
134 (5.27)
117 (4.60)
44 (1.73)
22 (0.86)
203 (7.99)
240 (9.45)
2 x M8
mounting
studs
Port A
Inlet
Port B
Outlet
Port C
Exhaust
70 (2.76)
Remember that overhaul
kits and replacement coil
housing assemblies are
available.
15
Hazardous Area
Zone 1
Maxseal
Direct Solenoid-Operated
Control Valve for Hazardous Areas
EEx d
Model SOV, Sizes 1 & 2 (1/2" - 3/4")
Certification
Description
EECS (BASEEFA) / CENELEC approved
EEx d IIC T6 or EEx d IIC T4 (Ta = 90ºC)
Complies with EN 50014:1997 and EN 50018:1977
A direct-acting solenoid
valve certified for hazardous
area use as well as general
air and gas purposes in the
offshore and petrochemical
industries.
2-port, EO
3-port
5-port
A
C
E
A
C
B
D
B
Standard Features
Options
Port thread
1/2"
Port configuration
3/2 Uni
-
3/4"
NPT
Operating pressure
0 - 20 bar(g) (0 - 290 psi)
Actuation method
Port connections
Female threaded
Flanged
1/2"
Automatic
Port configuration
5/2 Uni; 2/2 EO; 2/2 EC
Valve material
Stainless steel
BS EN 10088
Actuation method
Seat / Seal material
High nitrile (Buna N)
Autolatch, lever manual
reset (LMR), lever manual
override (LMO),
tamperproof manual reset
(see "Optional Valve
Features")
Operating voltage
Size 1
Size 2
24V DC; 18W at
20ºC (68ºF)
24V DC; 25W at
20ºC (68ºF)
Conduit / Signal entry
M20 x 1.5 mm ISO (F)
Paint finish
Standard (green) 40 µm
Coil housing material
Cast iron
BS EN 1561: 1997
Weight (approx.)
Cv value at 20 bar (290 psi)
1/2" model
3/4" model
Valve material
BSPP; 1/2" BSPT
- 3/4" BS 10, BS 1560
or BS 4504
1/2"
Brass BS EN 12163: 1998
Flanged/cast bodies
available on request
Seat / Seal material
Viton®, nylon 66
(high pressure seat only)
Alternative materials
available on request
3-port version: 20 kg (44 lb)
Operating voltages
3.2 (Kv 2.7)
6.8 (Kv 5.8)
DC: 12, 24, 48, 110, 125,
240
AC: 24, 50, 110, 240, 440
Conduit / Signal entry
1/2"
Paint
Epoxy (light grey) 150 µm
CV value
0 - 50 bar(g) (0 - 725 psi) +
Please contact us
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
16
2-port, EC
NPT, 13.5 PG
Hazardous Area
Zone 1
Maxseal
Direct Solenoid-Operated Control Valve for Hazardous Areas
EEx d
SOV, Sizes 1 & 2 (1/2" - 3/4")
Technical Specification
Protection
Ingress IP65 - IP68
Surge suppression diodes
Response times
Pull-in: please contact us
Drop-out: please contact us
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Operating pressure ranges
0
0
0
0
-
20 bar(g)
50 bar(g)
103 bar(g)
207 bar(g)
(0
(0
(0
(0
-
290 psi) (standard)
725 psi) bar stock body (option)
1494 psi) bar stock body (option)
3000 psi) bar stock body (option)
Dimensions in mm (inches)
(Size 2 3/4" solenoid 3/2 Uni configuration illustrated)
72.5 (2.85)
70 (2.76)
22
(0.86)
80 (3.15)
M20 x 1.5 mm ISO
conduit entry
72.5 (2.85)
65 (2.56)
2 x M8
mounting
studs
ø 89 (3.50)
107 (4.21)
162 (6.38)
35
(1.38)
32
(1.26)
50.8 (2)
25.4 (1)
242 (9.52)
304 (12)
25.4 (1.0)
Port A
Inlet
Port B
Outlet
Port C
Exhaust
82.5 (3.25)
We recommend installing a
strainer or filter as close as
possible to valve inlet. While
protecting seating areas
from potential damage, this
helps maintain air quality Talk to us about filtration!
17
Hazardous Area
Zone 1
Maxseal
Direct Solenoid-Operated
Control Valve for Hazardous Areas
EEx d
Model SOV, Sizes 3, 4, 5 & 6 (1" - 3")
Certification
Description
EECS (BASEEFA) /
CENELEC approved
EEx d IIC T6 or
EEx d IIC T4 (Ta = 90ºC)
Complies with
EN 50014:1997
and EN 50018:1977
A direct-acting solenoid
valve certified for hazardous
area use as well as general
air and gas purposes in the
offshore and petrochemical
industries.
Port thread
1" - 2" NPT
Port configuration
3/2 Uni
Operating pressure
0 - 20 bar(g) (0 - 290 psi)
Actuation method
Automatic
Valve material
Stainless steel
BS EN 10088
Seat / Seal material
High nitrile (Buna N)
24V
24V
24V
24V
DC;
DC;
DC;
DC;
40W
75W
100W
150W
Conduit / Signal entry
M20 x 1.5 mm ISO (F)
Paint finish
Standard (green) 40 µm
Coil housing material
Cast iron
BS EN 1561: 1997
35 kg (77 lb)
58 kg (128 lb)
65 kg (144 lb)
115 kg (254 lb)
Cv value at 20 bar (290 psi)
1" model
11/2" model
2" model
21/2" model
3" model
12.8 (Kv 11)
28 (Kv 24)
48 (Kv 41)
70 (Kv 60)
100 (Kv 86)
A
C
B
D
B
2-port, EC
Options
Port connections
Female threaded
Flanged
1" - 2" BSPP / BSPT
1" - 3" BS 10, BS 1560
or BS 4504
Port configuration
5/2 Uni; 2/2 EO; 2/2 EC
Actuation method
Autolatch, lever manual
reset (LMR), lever manual
override (LMO),
tamperproof manual reset
(see "Optional Valve
Features")
Valve material
Weight (approx.)
Size 3
Size 4
Size 5
Size 6
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
18
A
C
E
2-port, EO
Standard Features
Operating voltage
at 20ºC (68ºF)
Size 3
Size 4
Size 5
Size 6
3-port
5-port
Brass BS EN 12163: 1998
Flanged/cast bodies
available on request
Seat / Seal material
Viton®, nylon 66
(high pressure seat only)
Alternative materials
available on request
Operating voltages
DC: 12, 24, 48, 110, 125,
240
AC: 24, 50, 110, 240, 440
Conduit / Signal entry
1/2"
Paint
Epoxy (light grey) 150 µm
CV value
50 bar(g) (725 psi) +
Please contact us
NPT, 13.5 PG
Hazardous Area
Zone 1
Maxseal
Direct Solenoid-Operated Control Valve for Hazardous Areas
EEx d
SOV, Sizes 3, 4, 5 & 6 (1" - 3")
Technical Specification
Protection
Ingress IP65 - IP68
Surge suppression diodes
Response times
Pull-in: please contact us
Drop-out: please contact us
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Operating pressure ranges
0
0
0
0
-
20 bar(g)
50 bar(g)
103 bar(g)
207 bar(g)
(0
(0
(0
(0
-
290 psi) (standard)
725 psi) bar stock body (option)
1494 psi) bar stock body (option)
3000 psi) bar stock body (option)
Dimensions in mm (inches)
(Size 3 1" solenoid 3/2 Uni configuration illustrated. Double conduit thread for switches)
102 (4.0)
2 holes M20 x 1.5
conduit thread
ø 189 (7.44)
90 (3.54)
15 (0.59)
85.7 (3.37)
60.3
31.7
9.5
Port B
Outlet
(2.0)
(0.375) (1.25)
50.8
Port A
Inlet
ø 89 (3.50)
30 (1.18)
15 (0.59)
22
(0.86)
60 (2.36)
85
(3.34)
25 (0.98)
59 (2.32)
250 (9.84)
(1.57)
2 off
M8 x
1.25 mm
mounting
studs
(2.37)
403 (15.86)
157.5 (6.20)
40
50 (1.96)
Port C
Exhaust
ø 82.5 (3.24)
Remember that overhaul
kits and replacement coil
housing assemblies are
available.
19
Hazardous Area
Zones 1 and 2
Maxseal
Solenoid/Pilot-Operated Valve
for Hazardous Areas
EEx d, Ex N
Model POICO4 1/4"
Certification
Description
Pilot operated valve
optionally supplied with
ICO4S, ICO4D or ICO4N.
Refer to the relevant valves
for certification data.
A pilot-operated valve
certified for hazardous area
use as well as general
liquid and gas purposes in
the offshore and
petrochemical industries.
A
B
Standard Features
B
A
C
C
A
B
D
2-port, EC
A
C
A
C
E
2-port, EO
A
C
3-port
A
C
5-port
A
B
Options
Port thread
1/4"
NPT
Port configuration
3/2 Uni
Operating pressure
Main valve
Pilot valve
0 - 20 bar(g) (0 - 290 psi)
2 - 10 bar(g) (29 - 145 psi)
Port thread (pilot body)
1/4"
BSPP; 1/4" BSPT
Port configuration
5/2 Uni; 2/2 EO; 2/2 EC
Valve material
Brass BS EN 12163: 1998
Seat / Seal material
Viton®, nylon 66
(high pressure seat only)
Alternative materials
available on request
Operating voltages
DC: 12, 24, 48, 110, 125,
240
AC: 24, 50, 110, 240, 440
Actuation method
Solenoid-operated,
external pilot liquid/gas
assisted
Valve material
Stainless steel
BS EN 10088
Seat / Seal material
High nitrile (Buna N)
Conduit / Signal entry
1/2"
Operating voltage
24V DC; 4.5W (ICO4D/S)
at 20ºC (68ºF)
Paint
Epoxy (light grey) 150 µm
CV value
0 - 50 bar(g) (0 - 725 psi)
= 0.6 (Kv = 0.5)
0 - 103/207 bar(g)
(0 - 1494/3000 psi) = 0.28
(Kv = 0.24)
Conduit / Signal entry
M20 x 1.5 mm ISO (F)
Paint finish
Standard (green) 40 µm
Coil housing material
ICO4D and ICO4N
ICO4S
Cast iron BS EN 1561:1997
Stainless steel BS 3146
ANC.4 BFC.316
Weight
3-port version: 5 kg (11 lb)
Cv value
0.8 (Kv 0.69)
NPT, 13.5 PG
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
20
Hazardous Area
Zones 1 and 2
Maxseal
Solenoid/Pilot-Operated Valve for Hazardous Areas
EEx d, Ex N
POICO4 1/4"
Technical Specification
Protection
Ingress IP65 / IP68
Surge suppression diodes
Response times
(typical, dependent on coil size)
Pull-in < 150 ms
Drop-out < 80 ms
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Operating pressure ranges
Main valve
0 - 20 bar(g)
Up to 207 bar(g)
0 - 20 bar(g)
2 - 10 bar(g)
Pilot signal
(0 - 290 psi)
(3000 psi)
(0 - 290 psi)
(29 -145 psi)
2/2 and 3/2 ports
2/2 and 3/2 ports
5/2 port
2/2, 3/2 and 5/2 ports
Dimensions in mm (inches)
(ICO4N 3/2 Uni configuration illustrated)
ø 82.6 (3.25)
4
6 (1.81)
4
8 (1.88)
t el n I A t r o P
t el t u O B t r o P
tsu ah x E C t r o P
22
(0.86)
2 off
M8 x 1.25 mm
)1
)75.
11 (0.4
3)
Pilot inlet
2
Pilot exhaust
)0.1( )
2 - 10 bar(g)
(29 - 145 psi)
4.5
2 .1(
23
5.
)7
3. 3 ( 4 8
3 4.0( 11
)0
69( 761
)
2 .4( 701
2
)0.1(
4.5
y r tn e tiudno c
O SI m m 5.1 x 0 2 M
mounting
studs
(2 positions)
6 8 .0(
22
8 .0(
2. 2 2
)7
50.
8 (2.0)
101 (
3.97)
22.2
87)
(0.
145 (5.70)
Remember that overhaul
kits and replacement coil
housing assemblies are
available.
21
Hazardous Area
Zones 1 and 2
Maxseal
Dual Shuttle Valve
for Hazardous Areas
EEx d, Ex N
Dual Shuttle Valve 1/4" - 1/2"
Certification
Description
Dual shuttle valve
optionally supplied with
ICO4S, ICO4D or ICO4N.
Refer to the relevant valves
for certification data.
A valve certified for
hazardous area use as well
as general liquid and gas
purposes in the offshore
and petrochemical
industries.
5-port
2
4
3-port
3
2
3
5
1
1
Standard Features
Options
Port thread
Solenoid valve
Shuttle valve (female)
1/4"
Port configuration
3/2
Operating pressure
Main valve
Pilot valve
0 - 10 bar(g) (0 - 145 psi)
2 - 10 bar(g) (29 - 145 psi)
NPT
1/4" NPT
Port thread
Solenoid valve
Shuttle valve (female)
1/4"
BSPP; 1/4" BSPT
- 1/2" BSPP;
1/4" - 1/2" BSPT; 1/2" NPT
1/4"
Port configuration
5/2
Valve material
Brass BS EN 12163: 1998
Seat / Seal material
Viton®
Alternative materials
available on request
Operating voltages (solenoid)
DC: 12, 24, 48, 110, 125,
240
AC: 24, 50, 110, 240, 440
Actuation method
Solenoid-operated,
internal pilot gas
assisted
Valve material
Stainless steel
BS EN 10088
Seat / Seal material
High nitrile (Buna N)
Conduit / Signal entry
1/2"
Operating voltage
24V DC; 4.5W (ICO4D/S)
at 20ºC (68ºF)
Paint
Epoxy (light grey) 150 µm
CV value at 10 bar (145 psi)
1/2" model
3.2 (Kv 2.7)
Conduit / Signal entry
M20 x 1.5 mm ISO (F)
Paint finish
Standard (green) 40 µm
Coil housing material
ICO4D and ICO4N
ICO4S
NPT, 13.5 PG
Cast iron BS EN 1561:1997
Stainless steel BS 3146
ANC.4 BFC.316
Weight
Please contact us
Cv value at 10 bar (145 psi)
1/4" model
0.8 (Kv 0.69)
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
22
Hazardous Area
Zones 1 and 2
Maxseal
Dual Shuttle Valve for Hazardous Areas
EEx d, Ex N
Dual Shuttle Valve 1/4" - 1/2"
Technical Specification
Protection (solenoid)
Ingress IP65 / IP68
Surge suppression diodes
Response times
(typical, dependent on coil size)
Pull-in: Please contact us
Drop-out: Please contact us
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Dimensions in mm (inches)
(5/2 1/4" configuration illustrated)
183 (7.2)
2 x M8
mounting studs
2 positions
27.2 (1.07)
55 (2.16)
2
1
54.4 (2.14)
59 (2.32)
27.3 (1.07)
234 (9.21)
21.5 (0.87)
86 (3.38)
20 (0.78)
51(2.0)
58 (2.99)
5
89.4 (3.51)
M20 x 1.5 mm ISO
conduit entry
Exhaust
port
116 (4.56)
158 (6.22)
ø 80 (3.14)
186 (7.32)
4
3
We recommend installing a
strainer or filter as close as
possible to valve inlet. While
protecting seating areas
from potential damage, this
helps maintain air quality Talk to us about filtration!
23
Hazardous Area
Zones 1 and 2
Maxseal
Solenoid/Pilot-Operated Valve
for Hazardous Areas
EEx d, Ex N
Model POV 1/2" - 4"
A pilot-operated valve
certified for hazardous area
use as well as general
liquid and gas purposes in
the offshore and
petrochemical industries.
A
C
E
1/2"
Port configuration
1/2" - 4"
1/2" - 3"
1/2" - 2"
2/2 EO, 2/2 EC
3/2
5/2
Operating pressure
Main valve
Pilot valve
0 - 20 bar(g) (0 - 290 psi)
2 - 10 bar(g) (29 - 145 psi)
C
A
B
D
2-port, EC
B
A
C
Port thread
3-port
A
C
2-port, EO
Standard Features
Actuation method
5-port
A
C
Description
Pilot operated valve
optionally supplied with
ICO4S, ICO4D or ICO4N.
Refer to the relevant valves
for certification data.
A
C
Certification
- 2" NPT
Solenoid-operated,
external pilot liquid/gas
assisted
Valve material
Stainless steel
BS EN 10088
Seat / Seal material
High nitrile (Buna N)
Operating voltage
24V DC; 4.5W (ICO4D/S)
at 20ºC (68ºF)
Conduit / Signal entry
M20 x 1.5 mm ISO (F)
Paint finish
A
B
A
B
Options
Port thread (pilot body)
1/4"
BSPP; 1/4" BSPT
Port connections
Female threaded
1/2"
Flanged
1/2"
- 2" BSPP / BSPT
- 4" BS 10, BS 1504
or BS 4504
Valve material
Brass BS EN 12163: 1998
Seat / Seal material
Viton®, nylon 66
(high pressure seat only)
Alternative materials
available on request
Standard (green) 40 µm
Operating voltages
Cast iron BS EN 1561:1997
Stainless steel BS 3146
ANC.4 BFC.316
DC: 12, 24, 48, 110, 125,
240
AC: 24, 50, 110, 240, 440
Conduit / Signal entry
1/2"
Paint
Epoxy (light grey) 150 µm
Weight
Please contact us
CV value
Cv value at 20 bar (290 psi)
1/2" model
3/4" model
1" model
11/2" model
2" model
3" model
4" model
3.2 (Kv 2.7)
6.8 (Kv 5.8)
12.8 (Kv 11)
28 (Kv 24)
48 (Kv 41)
100 (Kv 86)
165 (Kv 142)
0 - 50 bar(g) (0 - 725 psi)
0 - 103/207 bar(g)
(0 - 1494/3000 psi)
Please contact us
Coil housing material
ICO4D and ICO4N
ICO4S
NPT, 13.5 PG
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
24
Hazardous Area
Zones 1 and 2
Maxseal
Solenoid / Pilot-Operated Valve for Hazardous Areas
EEx d, Ex N
POV 1/2" - 4"
Technical Specification
Protection
Ingress IP65 / IP68
Surge suppression diodes
Response times
Pull-in: please contact us
Drop-out: please contact us
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Operating pressure ranges
Main valve
Pilot signal
0 - 10 bar(g)
(0 - 145 psi)
0 - 20 bar(g)
(0 - 290 psi)
0 - 50 bar(g)
(0 - 725 psi)
0 - 103 bar(g)
(0 - 1494 psi)
0 - 138 bar(g)
(0 - 2001 psi)
0 - 207 bar(g)
(0 - 3000 psi)
2 - 10 bar(g)
(29-145 psi)
2/2 port 1/2" - 4"
3/2 port 1/2" - 3"
5/2 port 1/2" - 2"
2/2 port 1/2" - 4"
3/2 port 1/2" - 3"
5/2 port 1/2" - 2"
2/2 port 1/2" - 2"
3/2 port 1/2" to 11/2"
2/2 port 1/2" to 11/2"
3/2 port 1/2" to 1"
2/2 port 1/2" to 11/2"
3/2 port 1/2" - 1"
2/2 port 1/2" to 11/2"
3/2 port 1/2" - 1"
2/2, 3/2 and 5/2 ports
(option)
(option)
(option)
(standard)
(standard)
(standard)
(option)
(option)
(option)
(option)
(option)
(option)
(option)
(option)
Dimensions in mm (inches)
(3/2 Uni 3/4" configuration illustrated)
52 (2.05)
54 (2.12) 54 (2.12)
1/4"
76 (3.0)
210 (8.26)
Port A
Inlet
Port B
Outlet
Port C
Exhaust
118 (4.65)
45 (1.7)
50.8 (2.0)
Port A
Inlet
(1.0)
Port C
Vent
25.4
2 off
M10 x 1.5 mm
mounting studs
63.5 (2.5)
22.2 (0.87)
160 (6.30)
NPT
op. air inlet
2 - 10 bar(g)
(29 - 145 psi)
11 (0.43)
Conduit
entry
M20
x 1.5
mm
ISO
161 (6.33)
89 (3.5)
31.75
(1.25)
We recommend installing a
strainer or filter as close as
possible to valve inlet. While
protecting seating areas
from potential damage, this
helps maintain air quality Talk to us about filtration!
25
Hazardous Area
Zone 2
Maxseal
Instrument Changeover and Process
Control Valve for Hazardous Areas
Ex N
Model ICO4N 1/4"
Certification
Description
EECS (BASEEFA) approved
Ex N IIC T6
Ex N IIC T4 (Tamb = 90ºC)
Complies with BS 6941: 1988
A direct-acting solenoid
valve certified for hazardous
area use as well as general
air and gas purposes in the
offshore and petrochemical
industries.
3-port
2-port, EO
A
C
2-port, EC
B
Standard Features
Port thread
Options
1/4"
NPT
Port thread
1/4"
BSPP; 1/4" BSPT
Port configuration
3/2 Uni
Port configuration
2/2 EO; 2/2 EC
Operating pressure
0 - 20 bar(g) (0 - 290 psi)
Actuation method
Actuation method
Automatic
Valve material
Brass
BS EN 12163: 1998
Autolatch, lever manual
reset (LMR), lever manual
override (LMO),
tamperproof manual reset
(see "Optional Valve
Features")
Seat / Seal material
High nitrile (Buna N)
Operating voltage
24V DC; 7.8W
at 20ºC (68ºF)
Valve material
Stainless steel
BS EN 10088
Conduit / Signal entry
M20 x 1.5 mm ISO (F)
Seat / Seal material
Paint finish
Standard (green) 40 µm
Viton®,
Alternative materials
available on request
Coil housing material
Cast iron
BS EN 1561: 1997
Operating voltages
Weight
3-port version: 3.5 kg (7.7 lb)
DC: 12, 24, 50, 110, 125,
240
AC: 24, 50, 110, 240, 440
Cv value
0.8 (Kv 0.69)
Conduit / Signal entry
1/2"
Paint
Epoxy (light grey) 150 µm
CV value
0 - 50 bar(g) (0 - 725 psi)
= 0.6 (Kv = 0.5)
NPT, 13.5 PG
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
26
Hazardous Area
Zone 2
Maxseal
Instrument Changeover and Process Control Valve for Hazardous Areas
Ex N
ICO4N 1/4"
Technical Specification
Protection
Ingress IP65 - IP68
Surge suppression diodes
Response times
(typical, dependent on coil size)
Pull-in < 150 ms
Drop-out < 80 ms
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Operating pressure ranges
0 - 20 bar(g)
0 - 50 bar(g)
(0 - 290 psi) (standard)
(0 - 725 psi) (option)
Dimensions in mm (inches)
(3/2 Uni configuration illustrated)
22
(0.86)
48 (1.88)
M20 x 1.5 mm ISO
conduit entry
ø 82.6 (3.25)
46 (1.81)
ø 56 (2.20)
164 (6.45)
140 (5.5)
21.5 22.2
(0.85) (0.87)
11 (0.43)
62 (2.44)
84 (3.30)
25.4
(1.0)
2 x M8 mounting
studs (inline)
Port A
Inlet
Port B
Outlet
Port C
Exhaust
50.8 (2)
Remember that overhaul
kits and replacement coil
housing assemblies are
available.
27
Hazardous Area
Zone 2
Maxseal
Direct Solenoid-Operated
Control Valve for Hazardous Areas
Ex es
Model SOV, Sizes 1, 2, 3, 4, 5 & 6 (1" - 4")
Certification
Description
EECS (BASEEFA)
approved
Ex es II T6 or Ex es II T4
(ambient = 85ºC)
Complies with BS 5501:
Part 6:1977
A direct-acting solenoid
valve certified for hazardous
area use as well as general
air and gas purposes in the
offshore and petrochemical
industries.
Standard Features
28
A
C
E
1" - 2" NPT
Port configuration
3/2 Uni
Operating pressure
0 - 20 bar(g) (0 - 290 psi)
Actuation method
Automatic
Valve material
Stainless steel
BS EN 10088
Seat / Seal material
High nitrile (Buna N)
24V
24V
24V
24V
24V
24V
DC;
DC;
DC;
DC;
DC;
DC;
18W
25W
40W
75W
100W
150W
Conduit / Signal entry
M20 x 1.5 mm ISO (F)
Paint finish
Standard (green) 40 µm
Coil housing material
Cast iron
BS EN 1561: 1997
Weight (approx.)
Size 1
Size 2
Size 3
Size 4
Size 5
Size 6
20 kg (44 Ib)
30 kg (66 Ib)
35 kg (77 lb)
58 kg (128 lb)
65 kg (144 lb)
115 kg (254 lb)
Cv value at 20 bar (290 psi)
1" model
11/2" model
2" model
21/2" model
3" model
4" model
12.8 (Kv 11)
28 (Kv 24)
48 (Kv 41)
70 (Kv 60)
100 (Kv 86)
165 (Kv 142)
A
C
B
D
2-port, EO
Port thread
Operating voltage
at 20ºC (68ºF)
Size 1
Size 2
Size 3
Size 4
Size 5
Size 6
3-port
5-port
B
2-port, EC
Options
Port connections
Female threaded
Flanged
1" - 2" BSPP / BSPT
1" - 4" BS 10, BS 1560
or BS 4504
Port configuration
5/2 Uni; 2/2 EO; 2/2 EC
Actuation method
Autolatch, lever manual
reset (LMR), lever manual
override (LMO),
tamperproof manual reset
(see "Optional Valve
Features")
Valve material
Brass BS EN 12163: 1998
Flanged/cast bodies
available on request
Seat / Seal material
Viton®, nylon 66
(high pressure seat only)
Alternative materials
available on request
Operating voltages
DC: 12, 24, 48, 110, 125,
240
AC: 24, 50, 110, 240, 440
Conduit / Signal entry
1/2"
Paint
Epoxy (light grey) 150 µm
CV value
50 bar(g) (725 psi) +
Please contact us
NPT, 13.5 PG
Hazardous Area
Zone 2
Maxseal
Direct Solenoid-Operated Control Valve for Hazardous Areas
Ex es
SOV, Sizes 1, 2, 3, 4, 5 & 6 (1" - 4")
Technical Specification
Protection
Ingress IP65 - IP68
Surge suppression diodes
Response times
(typical, dependent on coil size)
Pull-in: Please contact us
Drop-out: Please contact us
Response times settings
Pull-in: within 87.5% of nominal (factory set at less than 75% of nominal)
Drop-out: normally 10-20% of nominal
Operating pressure ranges
0
0
0
0
-
20 bar(g)
50 bar(g)
103 bar(g)
207 bar(g)
(0
(0
(0
(0
-
290 psi) (standard)
725 psi) bar stock body (option)
1494 psi) bar stock body (option)
3000 psi) bar stock body (option)
Dimensions in mm (inches)
M20 x 1.5 mm ISO
conduit thread
(Size 2 3/4" solenoid 3/2 Uni configuration illustrated)
130 (5.1)
80 (3.14)
12.7 (0.5)
25.4 (1.0)
Port B
Outlet
135 (5.31)
63.5 (2.5)
Port A
Inlet
50.8
(2.0)
130 (5.1)
38.1
(1.5)
64.6 (2.54)
318.5 (12.5)
22 (0.86)
35
66
(2.6)
(1.37)
189 (7.4)
2 off
M8 x 1.25 mm
mounting studs
Port C
Exhaust
41.24
(1.6)
82.55 (3.25)
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
ø 89 (3.5)
We recommend installing a
strainer or filter as close as
possible to valve inlet. While
protecting seating areas
from potential damage, this
helps maintain air quality Talk to us about filtration!
29
Unclassified
Maxseal
Air Operated Valve
Model AOV 1/4"
Description
A general purpose
direct-acting valve for
liquid and gas
management in industrial
applications.
5-port
2-port, EO
3-port
A
C
E
A
C
B
D
A
B
Standard Features
2-port, EC
A
B
B
Options
Port thread
1/4"
NPT
Port configuration
3/2 Uni
Operating pressure
Main valve
Pilot signal
0 - 20 bar(g) (0 - 290 psi)
2 - 10 bar(g) (29 - 145 psi)
Actuation method
Liquid/gas operated
Valve material
Port thread
1/4"
Port configuration
5/2, 2/2 EO; 2/2 EC
Valve material
Stainless steel
BS EN 10088
Seat / Seal material
Brass
BS EN 12163: 1998
Viton®
Alternative materials
available on request
Paint
Epoxy (light grey) 150 µm
Seat / Seal material
High nitrile (Buna N)
CV value
Paint finish
Standard (green) 40 µm
0 - 50 bar(g) (0 - 725 psi)
= 0.6 (Kv = 0.5)
0 - 103/207 bar(g)
(0- 1494/3000 psi)
= 0.28 (kv = 0.24)
Weight
3-port version: 2 kg (4.4 lb)
Cv value
0.8 (Kv 0.69)
BSPP; 1/4" BSPT
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
30
Unclassified
Maxseal
Air Operated Valve
AOV 1/4"
Technical Specification
Response times
60 - 100 ms
Operating pressure ranges
Main valve
0 - 20 bar(g)
Up to 207 bar(g)
0 - 20 bar(g)
2 - 10 bar(g)
Pilot signal
(0 - 290 psi)
(3000 psi)
(0 - 290 psi)
(29 - 145 psi)
2/2 and 3/2 ports
2/2 and 3/2 ports
5/2 port
2/2, 3/2 and 5/2 ports
Dimensions in mm (inches)
(3/2 Uni configuration illustrated)
58 (2.28)
58 (2.28)
Note: Housing
size may vary
with different
pressure ratings
11 (0.43)
62 (2.44)
22.2
21.5
56 (2.20)
(0.87)
Port A
Inlet
Port B
Outlet
Port C
Exhaust
(0.85)
115 (4.52)
2 x M8
mounting
studs
50.8 (2)
For your convenience,
Operation and Maintenance
instructions are included
with each valve.
31
Unclassified
Maxseal
Air Operated Valve
Model AOV 1/2" - 4"
Description
A general purpose
direct-acting valve for
liquid and gas
management in industrial
applications.
5-port
2-port, EO
3-port
A
C
E
A
C
B
D
A
B
Standard Features
2-port, EC
A
B
B
Options
Port thread
1/2"
- 2" NPT
Port configuration
1/2" - 4"
1/2" - 3"
1/2" - 2"
2/2 EO, 2/2 EC
3/2
5/2
Operating pressure
Main valve
Pilot signal
0 - 20 bar(g) (0 - 290 psi)
2 - 10 bar(g) (29 - 145 psi)
Actuation method
Air operated, external
pilot liquid/gas assisted
Valve material
Brass
BS EN 12163: 1998
Seat / Seal material
High nitrile (Buna N)
Paint finish
Standard (green) 40 µm
Weight
Please contact us
Cv value
Please contact us
Port thread
1/2"
Port connections
Female threaded
Flanged
1/2"
BSPP; 1/2" BSPT
- 2" BSPP / BSPT
- 4" BS 10, BS 1504
or BS 4504
1/2"
Valve material
Stainless steel
BS EN 10088
Seat / Seal material
Viton®
Alternative materials
available on request
Paint
Epoxy (light grey) 150 µm
CV value
Please contact us
Viton® is a registered trademark of DuPont Dow Elastomers LLC.
32
Unclassified
Maxseal
Air Operated Valve
AOV 1/2" - 4"
Technical Specification
Response times
60 - 100 ms
Operating pressure ranges
Main valve
0 - 10 bar(g)
(0 - 145 psi)
0 - 20 bar(g)
(0 - 290 psi)
0 - 50 bar(g)
(0 - 725 psi)
0 - 103 bar(g)
(0 - 1494 psi)
0 - 138 bar(g)
(0 - 2001 psi)
0 - 207 bar(g)
(0 - 3000 psi)
2 - 10 bar(g)
(29-145 psi)
Pilot signal
2/2 port 1/2" - 4"
3/2 port 1/2" - 3"
5/2 port 1/2" - 2"
2/2 port 1/2" - 4"
3/2 port 1/2" - 3"
5/2 port 1/2" - 2"
2/2 port 1/2" to 2"
3/2 port 1/2" to 11/2"
2/2 port 1/2" to 11/2"
3/2 port 1/2" to 1"
2/2 port 1/2" - 11/2"
3/2 port 1/2" to 1"
2/2 port 1/2" - 11/2"
3/2 port 1/2" - 1"
2/2, 3/2 and 5/2 ports
(option)
(option)
(option)
(standard)
(standard)
(standard)
(option)
(option)
(option)
(option)
(option)
(option)
(option)
(option)
Dimensions in mm (inches)
(2/2 EO 4" configuration illustrated)
20
3 (8.0)
I
nlet - pilot
)5
7. 6 ( 5.1 7 1
)5
)0.
7 .21( 4 2 3
2
4 ( 6 .101 ø
)52.8( 01
Closed
Open
1
63.5 (6.43)
327 (12.875)
For your convenience,
Operation and Maintenance
instructions are included
with each valve.
33
Maxseal Solenoid Valves.
Optional Valve Features.
Automatic Latching
Lever.
Automatic (Standard).
An electrical and/or
air/gas supply energizes
the valve, opening,
closing or changing
over valve ports,
depending on model
and porting
configuration. When the
valve is de-energized, it
is spring-returned to its
original position.
When the solenoid is
energized, the lever
(standard) drops and
latches the valve in the
energized position.
On loss of electrical
supply, it remains
latched until manually
unlatched.
Lever in
reset
position,
i.e. valve
de-energized
to close
Valve
energized
"open"
when lever
is in position
shown
Lever Manual Reset.
After the valve operator
is energized, the manual
reset lever (or button)
must be operated to
move the valve to the
energized position.
When the valve is
de-energized, it is
spring-returned to its
original position.
Lever option:
ICO4 and SOV.
Button option:
ICO2 and ICO4.
Tamperproof Manual Reset.
Models ICO2 and ICO4 3-port only.
• When de-energized and with air on inlet port (A),
•
•
•
•
Lever Manual
Override.
A jackscrew or lever
(as shown) fitted to the
base of the valve moves
it to the energized or
de-energized position
without electrical power.
34
•
the valve will not change-over, even when the reset
button is pressed.
When the coil is energized and the reset button
pressed, the reset button lifts the spool
assembly into the magnetic field of the coil,
thereby holding the spool assembly in the
energized position.
No air will flow through the valve until the reset
button is released.
In the energized position, air flows from inlet
port (A), via the “gallery drilling”, through the
valve body and out through outlet
port (B). At this point,
exhaust port (C) is isolated.
When the coil is
de-energized, the
spool assembly is
spring-returned to the
Port B
de-energized position,
Outlet
Port C
isolating inlet port (A)
Exhaust
and venting air from
outlet port (B)
to exhaust port (C).
Port A
If the push button is
Inlet
held, jammed or
wire-locked in the
depressed position,
the air inlet supply
remains isolated.
Special Valve Features.
Indicating Switches.
High Temperature Spacer.
Micro-switches, available on models
SOV, AOV and POV only, indicate valve
open and closed positions (2 x spdt standard). They
can be fitted inside the coil housing (SOV) or to the
base of the main valve (AOV and POV), and are
electrically certified for the hazardous area required.
Available on models ICO4 and SOV direct-acting
solenoid valves only, high-temperature spacers are
fitted between coil housing and valve assembly
where media temperature exceeds 80ºC (176ºF).
This feature dissipates heat away from the coil
housing, preventing overheating of the coil itself.
1 2 3 4 5
6 7
8 9 10 11 12
Horizontal Mounting.
For SOV direct-acting solenoid valves only, this
feature is used on valves requiring the coil housing to
be installed horizontally. It prevents excessive wear of
dynamic seals within the valve body.
We are here to help!
Remember that complete spares
kits are available.
35
Intrinsic Safety.
This type of protection is
based on the minimum
energy needed to ignite
a hazardous
atmosphere. The risk of
ignition can be avoided
by designing the whole
circuit in such a way
that this energy is never
available, either under
normal operating
conditions or under
specific fault conditions.
Typical Intrinsically
Safe Circuit.
Hazardous area
Unlike other types of
protection which apply
to single electrical
devices, “intrinsic safety”
applies to the whole
electrical circuit. Intrinsic
safety implies:
An intrinsically safe
electrical device such as
a solenoid valve must
be installed together
with a safety device
which limits the available
power (energy) to
specific values.
• limiting peak current
and voltage at open
circuit conditions,
• limiting thermal and
electrical energy
storage.
Safe area
Supply via certified
energy limiting
device
PHOTOGRAPH COURTESY OF SHELL
36
Hazardous Area Installation Guidelines.
A simplified appreciation of hazardous area types
and risk levels involved.
The ultimate decision as
to what constitutes a
hazardous area (or zone)
rests with the company
chemist, usually in
consultation with health
and safety executives or
an authorizing body. The
role of the instrument or
1
design engineer is to
ensure that emergency
shutdown apparatus
(ESD), e.g. Maxseal
solenoid valves,
complies with operating
speed and zoning
requirements.
International Electrotechnical Commission
2
Most countries or trade
areas have their own
certifying authorities.
Hazardous area installation standards in force
in the EU are written by
CENELEC1/IEC2. They
can be certified by any
recognized authorizing
body, such as BASEEFA
in the UK, and enjoy
wide global acceptance,
except in the USA and
dollar areas where
American standards
prevail.
European Committee for Electrotechnical Standards.
Current CENELEC/IEC Hazardous
Area Classification.
An open area of plant or
factory is considered
hazardous when a fire or
explosion may result
from specific potential
conditions. Three zones
are defined:
Zone 0
(Category 1 from 2003
as per the ATEX
directive)
“An area in which a
hazardous or gas/air
mixture is continuously
present or present for
long periods.”
Zone 1
(Category 2 from 2003
as per the ATEX
directive)
“An area in which a
hazardous gas/air
mixture is likely to occur
in normal operation.”
Zone 2
(Category 3 from 2003
as per the ATEX
directive)
“An area where a
hazardous gas/air
mixture is unlikely to
occur under normal
operation, but if it
occurred it would only
be for a short duration.”
Both the risk level and zoning definition are affected by ventilation, quantity and
type of gas (heavier/lighter than air), as well as the need for a heat source to
prompt ignition.
37
Hazardous Area Coding System.
Solenoids should be
selected according to
the standard
identification code for
hazardous area
equipment.
E Exd IIC T6
CENELEC
approved
Type of
protection e.g.
“flameproof”
Gas group
e.g. “group II for
hydrogen”
See paragraph 1
See paragraph 2
Surface
temperature
rating e.g.
“85°C”
See paragraph 3
1. Protection
Methods in
Hazardous Areas.
3
Theoretical. Little precedent
for use in Zone 1.
Type
Symbol
Zone
Comments
Flameproof
‘d’
1 &2
Relies on containment of any explosion
inside the coil housing
Intrinsic safety
‘ia’
0
Increased safety
‘e’
1&2
Relies on design criteria
Non-incendive
‘N’
2
Relies on design criteria
3
Low power technique. Insignificant
energy to create an explosion.
(permits two failure conditions)
Other protection methods such as oil immersion (‘o’) or powder filling (‘q’) are
usually associated with products other than solenoid valves.
2. Apparatus or
Gas Groups.
There are 2 main gas
groups:
Group I relates
specifically to mining
applications.
Group II applies to all
applications other than
mining and is
subdivided into:
Group IIA - Propane
Group IIB - Ethylene
Group IIC - Hydrogen
Group IIA includes the
least incendive gases
and IIC the most
incendive. For
standardization and
safety reasons, valve
manufacturers usually fit
solenoids certified for
group IIC gases.
It should be noted that
American incendivity
groups go in reverse, A
being the most
incendive and D the
least.
PHOTOGRAPH COURTESY OF BAE SYSTEMS MARINE LIMITED
We are here to help!
Protect your system with a relief valve.
38
3. Surface
Temperature.
4
Most gases will not
ignite without a heat
source. This could be
any heated object, not
necessarily a naked
flame, approaching the
gas flash point.
Hazardous area
equipment is therefore
designed to limit surface
temperature in
continuous or
intermittent operation,
so as to minimize the
risk of ignition of
surrounding gases.
‘G’ in Germany.
5
Based on an ambient
of 40°C (104ºF).
Apparatus
Temperature
Classification
Class Maximum
(T)4
Surface
Temperature (°C/ºF)5
T1 450°C/842ºF
T2 300°C/572ºF
T3 200°C/392ºF
T4 135°C/275ºF
T5 100°C/212ºF
T6
85°C/185ºF
Maxseal solenoid valves
can be installed in
ambient temperatures of
up to 90°C (194ºF)
while still retaining a
T4 rating.
Hazardous areas standards for dust and fibres (zones 10 and 11) are not covered
here, nor are the USA standards. Please contact FCX Thompson Valves regarding
these types of hazardous areas, and any other matter where installation guidance
or valve selection information is needed.
PHOTOGRAPH COURTESY OF SHELL
General Note.
39
Maxseal Solenoid Valves.
Valve Flow Characteristics.
Table 1
Flow Coefficients
Valve Type
Nominal
Size
Flow
Path
(")
(mm)
1/4
6
10
15
20
25
32
40
50
60
75
100
3/8
1/2
3/4
1
11/4
11/2
2
21/2
3
4
Cv
Kv
(bar g)
Valve Flow Coefficients
C
B
Conductance Critical
Pressure
(l/s/
Ratio
bar abs)
(USgpm
for 1 psi ∆p)
(l/min
(m3/hr
for 1 bar ∆p) for 1 bar ∆p)
20
20
20
20
20
20
20
20
20
20
20
3.7
10
15
27
50
70
106
190
270
380
630
0.8
1.7
3.2
6.8
12.8
18
28
48
70
100
165
11.5
24.5
46
98
184
259
403
691
1008
1440
2376
Maximum
Pressure
Any
Any
Any
Any
Any
Any
Any
Any
Any
Any
Any
Density
Relative
to Air (G)
1.0
0.068
0.96
1.10
0.138
1.38
0.69
2.90
4.55
1.52
0.96
0.59
0.55
Symbol
N2 + O 2
H2
N2
O2
He
A
Ne
Kr
Xe
CO2
CO
NH3
CH4
Actual
Density
(kg/m3)
1.2
0.082
1.15
1.32
0.166
1.66
0.83
3.48
5.46
1.824
1.15
0.71
0.67
Density figures at 293ºK and 1.018 bar (14.7 psi).
Glossary of Terms.
Conductance (C) The conductance is a constant
value that is the ratio of airflow across the valve to
inlet pressure p1 at choked flow conditions.
Critical Pressure Ratio (B) The critical pressure
ratio of a pneumatic component is the ratio of outlet
pressure to inlet pressure where choked flow is
reached.
Table 3
Media Characteristics - Liquids
40
0.69
1.46
2.75
5.84
11
15.5
24
41.2
60.2
86
141.9
We are here to help!
www.fcx-thompson-valves.com
Table 2
Media Characteristics - Gases
Medium
Air
Hydrogen
Nitrogen
Oxygen
Helium
Argon
Neon
Krypton
Xenon
Carbon dioxide
Carbon monoxide
Ammonia
Methane
0.32
0.33
0.35
0.35
0.36
0.38
0.39
0.39
0.4
0.4
0.4
Kv
Medium
Symbol
Mass
Density (kg/l)
Water
Heavy water
Shell Tellus T15
Olive oil
Ethanol
H2O
D2O
C2H5OH
1.0
1.1
0.86
0.9
0.8
Kv The Kv value for a valve is the flow rate of water
through the valve in l/min or in m3/hr when the ∆p
across the valve is 1 bar.
Cv The Cv value for a valve is the flow rate of water
through the valve in USgpm for a 1 psi ∆p.
Liquid Flow.
Gas Flow.
The flow rate of a liquid through a valve is given by:
The following modes of calculation are based on
BS 7294:1990; ISO 6358:1989.
Q = Kv •
∆p
γ
Where:
Q = Flow rate l/min
γ = Mass density in kg/l at process temperature
and pressure (water @ 20ºC = 1 kg/l)
∆p = p1 - p2
p1 = inlet pressure in bar abs.
p2 = outlet pressure in bar abs.
Kv = Flow rate of water through the valve in l/min
when ∆p across the valve is 1 bar. For
comparison and conversion purposes, the Cv
(USgpm for 1 psi) and Kv (m3/hr for 1 bar) are
also given in Table 1.
1. For non-choked flow (low flow conditions i.e.
p2/p1>B)
p2
Q =
C • p1
√G
T0
•
•
T1
1-
p1
2
-B
1-B
Where:
Q = Flow rate in normal (N) l/s
C = Conductance in l/s/bar abs. See Table 1.
B = Critical pressure ratio. See Table 1.
p = Pressure in bar abs.
p1 = inlet pressure in bar abs.
p2 = outlet pressure in bar abs.
G = Specific gravity relative to air.
T = Temperature.
T0 = 293ºK
T1 = Upstream temperature ºK
2. For choked flow (high flow conditions i.e. p2/p1<B)
Q =
C • p1
√G
T0
•
T1
Critical
pressure
ratio
Choked
flow
Non-choked
flow
Flow rate
Varying
inlet
pressure
p2
We are here to help!
When you've browsed this overview,
talk to us about the best solution
for your system.
41
Maxseal Solenoid Valves.
Valve Flow Characteristics.
Example Gas Flow Calculations.
Non-choked flow.
What is the maximum flow of methane through a 1"
SOV with an inlet pressure of 15 bar and a pressure
drop of 7 bar?
Choked flow.
What is the maximum flow of air (to atmosphere)
through a 1/4" ICO4 valve with an inlet pressure of 4.5
bar?
Is the flow choked?
For choked flow, p2/p1 = 0.36 (critical pressure ratio).
p2, the outlet pressure, is equal to 9 bar abs (16 - 7
bar) and p1, the inlet pressure, is equal to 16 bar abs
(1 + 15 bar).
Is the flow choked?
For choked flow, p2/p1 = 0.32 (critical pressure ratio).
p2, the ambient air pressure, is equal to 1 bar abs
and p1, the inlet pressure, is equal to 5.5 bar abs
(1 + 4.5 bar).
As p2/p1 = 0.56, the flow is choked.
As p2/p1 = 0.18, the flow is choked.
Determine flow
Using Table 1, conductance C for 1" valve =
50 l/s/bar abs
And, from Table 2, specific gravity of methane
relative to air is 0.55
Determine flow
Using Table 1, conductance C for 1/4" valve =
3.7 l/s/bar abs
Therefore
Q = C • p1 = 3.7 x 5.5 = 20.4 l/s
Therefore
p2
Q =
C • p1
√G
1-
p1
2
-B
1-B
=
9
50 x 16
0.55
1-
16
2
- 0.36
= 1022 l/s
1 - 0.36
We are here to help!
Filters contribute to longer system life.
42
Valve Flow Performance.
Chart 1.
Air Flow, ICO4 1/4", Low Pressure
20 bar max., universal
C = 3.7, B = 0.3, Cv = 0.8 USgpm
90
80
Inlet pressure (bar g)
Flow rate (N l/s) air
70
20
60
18
50
16
14
40
Ex. 2
30
12
10
8
20
6
4
10
0
0
5
10
15
Outlet pressure (bar g)
Ex. 1
20
25
Example 1: What is the flow rate at 20 bar inlet and
18 bar outlet pressures (i.e. 2 bar ∆p)?
Answer: 40 N l/s.
Example 2: What is the ∆p at inlet 10 bar and 32 l/s flow?
Answer: 10 - 7 = 3 bar.
Chart 2.
Air Flow, ICO4 1/2", Low Pressure
20 bar max., universal
C = 15, B = 0.35, Cv = 4.2 USgpm
350
300
Flow rate (N l/s) air
Inlet pressure (bar g)
250
20
18
200
16
14
150
12
10
100
8
6
4
50
0
0
5
10
15
20
25
Outlet pressure (bar g)
43
Maxseal Solenoid Valves.
Valve Flow Performance.
Chart 3.
Liquid Flow, ICO4 1/4", Low Pressure
20 bar max., Cv = 0.8 USgpm
Fluid water at density 1 kg/l
70.0
Flow rate (N l/min) water
60.0
50.0
40.0
30.0
Inlet pressure (bar g)
20.0
10.0
2
6
4
8
12
10
14
16
18
20
0.0
0
5
10
15
20
25
Outlet pressure (bar g)
Chart 4.
Liquid Flow, ICO4 1/4", High Pressure
207 bar max., Cv = 0.28 USgpm
160.0
140.0
Flow rate (N l/min) water
120.0
100.0
80.0
Inlet pressure (bar g)
60.0
40.0
20
20.0
60
40
80
100
120
140
160
180
207 220
0.0
0
50
100
150
Outlet pressure (bar g)
44
200
250
Chart 5.
Flow Test, ICO4 1/4"
90
80
70
Q
Flow rate (N l/s)
60
N
M
P
O
50
L
I
J
40
R
K
H
30
G
D
20
B
C
F
A
E
10
0
0
5
10
15
20
25
Outlet pressure (bar g)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
Theoretical flow for 4 bar g inlet pressure
Actual flow for 4 bar g inlet pressure
Theoretical flow for 6 bar g inlet pressure
Actual flow for 6 bar g inlet pressure
Theoretical flow for 8 bar g inlet pressure
Actual flow for 8 bar g inlet pressure
Theoretical flow for 10 bar g inlet pressure
Actual flow for 10 bar g inlet pressure
Theoretical flow for 12 bar g inlet pressure
Actual flow for 12 bar g inlet pressure
Theoretical flow for 14 bar g inlet pressure
Actual flow for 14 bar g inlet pressure
Theoretical flow for 16 bar g inlet pressure
Actual flow for 16 bar g inlet pressure
Theoretical flow for 18 bar g inlet pressure
Actual flow for 18 bar g inlet pressure
Theoretical flow for 20 bar g inlet pressure
Actual flow for 20 bar g inlet pressure
45
Maxseal Solenoid Valves.
Valve Flow Performance.
Chart 6.
Flow Test, ICO4 1/2"
At 10 bar inlet pressure for lift of 0.055"
200
180
Actual flow rate
160
Theoretical flow rate
Flow rate (N l/s)
140
120
100
80
60
40
20
0
0
2
4
6
8
10
12
Outlet pressure (bar g)
Chart 7.
Flow Test, ICO4 1/2"
At 20 bar inlet pressure for lift of 0.055"
400
Actual flow rate
350
Flow rate (N l/s)
300
Theoretical flow rate
250
200
150
100
50
0
0
5
10
15
Outlet pressure (bar g)
46
20
25
Maxseal Solenoid Valves.
Conversion Chart.
To convert
Unit (Symbol)
into
Unit (Symbol)
To convert
Unit (Symbol)
from
Unit (Symbol)
atmospheres (Atm)
bar (bar)
1.013250
cubic feet
(ft3)
Multiply by
Divide by
litres (l)
28.3161
cubic inches (in3)
centilitres (cl)
1.63866
feet (ft)
metres (m)
0.3048
feet of water (ft H2O)
bar (bar)
0.0298907
foot pounds force (ft lbf)
joules (J)
1.35582
foot pounds force/minute (ft lbf/min)
watts (W)
81.3492
gallons, UK (UK gal)
litres (l)
4.54596
gallons, US (US gal)
litres (l)
3.78531
horsepower (hp)
kilowatts (kW)
0.7457
inches of mercury (in Hg)
millibar (mbar)
33.8639
inches of water (in H2O)
millibar (mbar)
2.49089
inches (in)
centimetres (cm)
2.54
kilogramme force (kgf)
newtons (N)
9.80665
kilogramme force metre (kgf m)
newton metres (Nm)
9.80665
kilopascals (kPa)
bar (bar)
0.01
millimetres of mercury (mm Hg)
millibar (mbar)
1.33322
millimetres of water (mm H2O)
millibar (mbar)
0.09806
bar (bar)
0.1
kilogrammes (kg)
0.4536
newtons/square centimetre
(N/cm2)
pounds (lb)
pounds/cubic foot (lb/ft3)
pounds/cubic inch
kilogrammes/cubic metre (kg/m3)
(lb/in3)
kilogrammes/cubic centimetre
(kg/cm3)
16.0185
0.0276799
pounds force (lbf)
newtons (N)
4.44822
pound force feet (lbf ft)
newton metres (Nm)
1.35582
newton metres (Nm)
0.112985
bar (bar)
0.06894
pounds force inches (lbf in)
pounds force/square inch
square feet
(ft2)
square inches (in2)
(lbf/in2)
square metres
(m2)
square centimetres (cm2)
0.092903
6.4516
We are here to help!
Remember that complete spares
kits are available.
47
FCX Thompson Valves designs and
manufactures exclusive valve products
for the most demanding applications.
We offer cost-effective integrated
product packages, supported by the
resources of the FCX Flow Control
division.
Maxseal Solenoid
Valves
Resilient, low power
consumption, fast
acting instrument
changeover and
solenoid valves.
Ashford BellowsSealed and Gland
Packed Needle Valves
and Manifolds
Compact, lightweight
and robust, widely used
in nuclear applications.
Maxseal IVP Pressure
Regulators
NHI Bellows-Sealed
Globe Valves
Pressure regulators and
relief valves with high
performance accuracy
for all process fluids,
including nuclear
applications.
High-integrity forged
valves, specifically
designed for nuclear
duties.
Service and
Refurbishment Centre
Specialist Packaged
Solutions
Dedicated service
engineers for installation
and refurbishment.
• HP air management
systems.
• Cryogenic valves for
aerospace
applications.
product specifications or designs without notice.
Information is given in good faith and no liability can
be accepted for any error or omission.
Classes 1, 2 and 3
A Division of FCx Manufacturing UK Ltd
QACA 225 Rev. 3
BASEEFA/EECS
Licence M3782
BS EN ISO 9001: 1994
Certificate No. FM 315
FCX Thompson Valves
17 Balena Close
Creekmoor, Poole
Dorset BH17 7EF, England
Tel +44 (0)1202 697521
Fax +44 (0)1202 605385
[email protected]
www.fcx-thompson-valves.com
FRONT COVER PHOTOGRAPH COURTESY OF SHELL