LST Range
Transcription
LST Range
LST Range Safety i Plus i Plus 72 models CPD BIM Heights: 500mm, 650mm & 800mm Lengths: 650mm to 2050mm Outputs: 196 to 2767 watts, 669 to 9441 Btu/hr Types: K1, P+ & K2 For more information call 0844 543 6200 or visit www.stelrad.com Follow us on: @stelrad facebook.com/stelradlimited The Stelrad you know and so much more... Stelrad LST Range i Plus K1 50 Δt (75/65/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm UIN 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 145200 145201 145202 145203 145204 145205 145206 145207 145208 145209 145210 145211 145212 145213 145214 145215 145216 145217 145218 145219 145220 145221 145222 145223 P+ Heat output Watts Btu/hr 196 293 391 489 587 685 782 880 290 435 580 725 870 1015 1160 1305 365 548 730 913 1096 1278 1461 1643 669 1000 1334 1668 2003 2337 2668 3003 989 1484 1979 2474 2968 3463 3958 4453 1245 1870 2493 3115 3740 4361 4985 5606 UIN 145248 145249 145250 145251 145252 145253 145254 145255 145256 145257 145258 145259 145260 145261 145262 145263 145264 145265 145266 145267 145268 145269 145270 145271 K2 Heat output Watts Btu/hr 284 426 568 710 852 994 1136 1278 386 580 773 966 1159 1352 1546 1739 501 751 1002 1252 1502 1753 2003 2254 969 1454 1938 2423 2907 3392 3876 4361 1317 1979 2637 3296 3955 4613 5275 5933 1709 2562 3419 4272 5125 5981 6837 7691 UIN 145224 145225 145226 145227 145228 145229 145230 145231 145232 145233 145234 145235 145236 145237 145238 145239 145240 145241 145242 145243 145244 145245 145246 145247 Heat output Watts Btu/hr 348 522 696 870 1044 1218 1392 1566 478 717 956 1195 1434 1673 1912 2151 615 922 1230 1537 1844 2152 2459 2767 1187 1781 2375 2968 3562 4156 4750 5343 1631 2446 3262 4077 4893 5708 6524 7341 2098 3146 4197 5244 6295 7343 8393 9441 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). K1 40 Δt (55/45/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 UIN P+ Heat output Watts Btu/hr 145200 147 145201 219 145202 292 1145203 366 145204 439 145205 512 145206 585 145207 658 145208 217 145209 325 145210 434 145211 542 145212 651 145213 759 145214 868 145215 976 145216 273 145217 410 145218 546 145219 683 145220 820 145221 956 145222 1093 145223 1229 500 748 998 1248 1498 1748 1996 2246 740 1110 1480 1850 2220 2590 2961 3331 932 1399 1863 2330 2797 3262 3729 4193 UIN 145248 145249 145250 145251 145252 145253 145254 145255 145256 145257 145258 145259 145260 145261 145262 145263 145264 145265 145266 145267 145268 145269 145270 145271 K2 Heat output Watts Btu/hr 212 319 425 531 637 744 850 956 289 434 578 723 867 1011 1156 1301 375 562 749 936 1123 1311 1498 1686 725 1087 1450 1812 2174 2537 2899 3262 985 1480 1973 2465 2958 3451 3946 4438 1279 1917 2557 3195 3833 4474 5112 5753 UIN 145224 145225 145226 1145227 145228 145229 145230 145231 145232 145233 145234 145235 145236 145237 145238 145239 145240 145241 145242 145243 145244 145245 145246 145247 Heat output Watts Btu/hr 260 390 521 651 781 911 1041 1171 358 536 715 894 1073 1251 1430 1609 460 690 920 1150 1379 1610 1839 2070 888 1332 1776 2220 2664 3109 3553 3997 1220 1830 2440 3050 3660 4270 4880 5490 1570 2353 3139 3923 4706 5492 6276 7062 Stelrad LST Range i Plus K1 30 Δt (55/45/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm UIN 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 145200 145201 145202 145203 145204 145205 145206 145207 145208 145209 145210 145211 145212 145213 145214 145215 145216 145217 145218 145219 145220 145221 145222 145223 P+ Heat output Watts Btu/hr 101 151 201 252 302 353 403 453 149 224 299 373 448 523 597 672 188 282 376 470 564 658 752 846 344 515 687 859 1031 1204 1374 1546 510 764 1019 1274 1529 1784 2038 2293 641 963 1283 1604 1926 2246 2567 2887 UIN K2 Heat output Watts Btu/hr 145248 146 145249 219 145250 293 145251 366 145252 439 145253 512 145254 585 145255 658 145256 199 145257 299 145258 398 145259 497 145260 597 145261 696 145262 796 145263 896 145264 258 145265 387 145266 516 145267 645 145268 774 145269 903 145270 1032 145271 1161 499 749 998 1248 1497 1747 1996 2246 678 1019 1358 1697 2037 2376 2717 3056 880 1320 1761 2200 2639 3080 3520 3961 Heat output Watts Btu/hr UIN 145224 145225 145226 145227 145228 145229 145230 145231 145232 145233 145234 145235 145236 145237 145238 145239 145240 145241 145242 145243 145244 145245 145246 145247 179 269 358 448 538 627 717 806 246 369 492 615 739 862 985 1108 317 475 633 792 950 1108 1266 1425 611 917 1223 1529 1834 2140 2446 2752 840 1260 1680 2100 2520 2940 3360 3780 1081 1620 2161 2701 3240 3781 4321 4862 EN 442 Certification Data - CETIAT tested in accordance with BS EN442 Type Casing Height Emitter Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) Weight (kg/m) Water Contents (l/m) K1 500 300 489 1.19 2.09 17.80 1.89 650 450 725 1.25 3.37 23.50 2.57 P+ 800 600 913 1.34 4.66 29.40 3.25 500 300 710 1.24 2.44 22.70 3.70 650 450 966 1.27 3.84 30.72 5.15 K2 800 600 1252 1.31 5.24 38.40 6.60 500 300 870 1.27 3.51 24.40 3.70 650 450 1195 1.30 5.62 33.30 5.15 800 600 1537 1.32 7.74 42.50 6.60 LST i Plus wall fixings and bracket positions All dimensions in mm. Inches in brackets. 100 (3.93) 270 (10.63) 134 (5.27) 102 (4.01) Casing Height 500 650 800 Casing Height Casing Length 650 850 1050 24 (0.94) 270 (10.63) 237 (9.33) 237 (9.33) Casing Length 24 (0.94) Casing Height 500 650 800 134 (5.27) B 448 548 648 748 848 100 (3.93) A 415 515 615 715 815 Casing Height Casing Length 1250 1450 1650 1850 2050 270 (10.63) A 102 (4.01) 270 (10.63) 237 (9.33) 237 (9.33) B Casing Length LST i Plus connection options All dimensions in mm. Inches in brackets. 25 (0.98) A Casing Height 87 (3.42) Casing Height A 500 250 650 400 800 550 35 (1.37) 60 (2.36) 50 (1.96) 87 (3.42) Control on left-hand side 35 (1.37) 50 (1.96) Pipe configurations 120 (4.72) 132 (5.19) Control on right-hand side LST Range Components LST Standard front case view. LST Standard inside the casing showing the emitter. LST Standard emitter, showing high level valve option (valve not included). LST Standard circular knockout for TRV. Oblong knockout for pipe. LST Plus inside the casing showing the emitter. LST Vertical front case view. LST i Plus front case view. LST i Plus inside the casing showing the emitter. LST Plus front case view. LST Plus and LST i Plus Components Optional cover cap to discourage unauthorised tampering. An arthritic adaptor is supplied as standard for special needs environments. Accommodated within the casing, the Stelrad LST Plus emitter, with TBSE valve arrangement and 2 x 1⁄2" BSP connections as standard. Connection arrangement bottom. Connection arrangement top. The Stelrad STARS Heatloss Calculator contains an inbuilt U value calculator. Save time and effort by using the Stelrad STARS program - the perfect solution for accurate sizing and design flexibility. www.starsapp.co.uk Includes Danfoss RA-2000 TRV and copper pipe configuration. The remote sensing thermostatic valve gives accuracy of operation and the limiting device is completely hidden to prevent the maximum temperature being exceeded.