Low Surface Temperature Collection
Transcription
Low Surface Temperature Collection
Safety Series Low Surface Temperature Collection 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:34 Page 36 LST Range Standard Stelrad’s range of Low Surface Temperature radiators is the most comprehensive in the UK, with sizes and models to suit all applications. They all meet NHS Guidance for ‘safe hot water and surface temperature’ and are finished with antibacterial paint as standard, making them the No.1 choice for safety-critical environments. Installation is simple and all components are included in a single robust pack. Standard 72 models Heights: 500mm, 600mm & 800mm CPD BIM Lengths: 560mm to 1960mm Outputs: 196 to 2767 watts, 668 to 9442 Btu/hr Types: K1, P+ & K2 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:34 Page 37 LST Range Plus Vertical Plus Vertical 3 models Height: 2110mm Lengths: 560mm, 660mm & 760mm Outputs: 1335 to 1862 watts, 4555 to 6353 Btu/hr Type: K2 CPD BIM 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:34 Page 39 LST Range i Plus i Plus 72 models Heights: 500mm, 650mm & 800mm Lengths: 650mm to 2050mm Outputs: 196 to 2767 watts, 669 to 9441 Btu/hr Types: K1, P+ & K2 CPD BIM 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:35 Page 127 Safety Stelrad has created a range of Low Surface Temperature radiators which provide the perfect solution for all specification requirements in safety critical environments. The complete choice Stelrad LST range offers you the flexibility you need The first coat of paint is applied by electrophoresis and the radiator is then stoved and cooled • The LST Standard leaves you free to specify your preferred controls • Followed by a second powder coat in warm white, the emitter then goes through a final curing stage. It is then allowed to cool prior to packaging • The LST Plus and LST i Plus offer an integral remote sensing thermostat valve, the highly specified Danfoss RAS-D Remote Sensor • All exposed painted surfaces are finished in a long lasting anti-bacterial coating • The LST Vertical is ideal where space is at a premium LST i Plus • An arthritic adaptor is supplied as standard for less able environments - along with a lockshield valve which can only be adjusted with a 6mm Allen key, hidden with a neat metal dust cover to discourage unauthorised tampering. (excludes LST Standard) Remote sensing thermostatic valve The complete package • Special tools are not required, as the valve is gland seal removable • Every Stelrad LST radiator is supplied with an attractive, flat panel outer casing, which is totally reversible to allow piping flexibility • Simple and quick to install, the casing is held by security fittings with a unique seam fixing bracket system to prevent unauthorised access to the emitter accommodated inside • For added protection, the smooth surface is coated in anti-bacterial paint • The emitter provides high outputs through convection for outstanding heating performance • Controlled independent laboratory testing ensures that each emitter is guaranteed to perform to a maximum working pressure of 116 psi (8 bar) and conform to BS EN 442, the European Standard for radiators • The Danfoss RAS-D Remote Sensor is designed specifically for commercial heating systems and can be pre-set to allow adjustment of room temperature between 5°C and 26°C • Suitable for both 1⁄2" steel and 15mm copper piping, with left or right hand, same end connections for flow and return, gives flexibility of installation Lockshield valve • Able to withstand 10 bar static pressure, the valve has a drain tap adaptor available, which can also be used as a filling point • Mandatory fittings should be used in order to comply with current water regulations Connections • 2 x 1⁄2" connections as standard, complete with Danfoss remote sensing thermostatic radiator valve, pre-piped with 2 x 1⁄2" BSP connections at 50mm centres positioned at either left or right of the casing • All specified components required supplied in one robust package Anti-bacterial paint • Every LST emitter is subjected to a multi-stage cleaning process before the paint is applied. This involves several rinsing stages, including an iron phosphate and demineralisation phase CP BIM For further information and advice call 0844 543 6200 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:35 Page 128 LST Standard, LST i Plus & LST Vertical temperature table For systems not operating at ∆t50 the factors in the table below should be applied. The output of a given radiator can be obtained by multiplying the quoted ∆t50 output by the operating factor. Conversely, to derive a non ∆t50 output, divide the heat output required by the relevant operation factor. This ‘∆t50 equivalent output’ can then be used to select a radiator from the standard tables. ∆t °C Operating Factor ∆t °F Operating Factor 5 0.050 10 0.057 10 0.123 20 0.142 15 0.209 30 0.240 20 0.304 40 0.348 25 0.406 50 0.466 30 0.515 60 0.590 35 0.629 70 0.721 40 0.748 80 0.858 45 0.872 90 1.000 50 1.000 100 1.147 55 1.132 110 1.298 60 1.267 120 1.454 65 1.406 130 1.613 70 1.549 150 1.776 75 1.694 - - Example: Exact output at ∆t50 = 2000 Btu/hr Output at ∆t30 = 2000 x 0.515 = 1030 Btu/hr Average coefficient of 130 is used in the example above Testing and operating pressures All models are high pressure tested to withstand 152.3 psi (10.5 bar). Strictly controlled independent laboratory testing ensures that all Stelrad radiators are guaranteed to perform to a maximum working pressure of 116 psi (8 bar) at a maximum temperature of 95°C. All conform to BS EN 442 - the European Standard for radiators. Caution To ensure that the emitter complies with all aspects of the NHS guidance for “Safe hot water and surface temperature”, Stelrad recommends that a maximum flow temperature of 80° be used with a 20° drop across the system. When designing for domestic systems we recommend that the Stelrad LST range be used only in heating systems complying with the British Standard Code of Practice for Central Heating for Domestic Premises BS EN 12828:2003 and BS EN 12831:2003. Single feed, indirect cylinders are not recommended as should interchange of water occur, fresh aerated water would enter the heating system, resulting in corrosion. Water treatment On completion of the installation, the system should be properly flushed and filled in accordance with the British Standard Code of Practice BS 7593:2006 for the Treatment of Water in Domestic Hot Water Central Heating Systems, Part L of Building Regulations and Good Practice Guidance for Scotland. After installation of a new Stelrad radiator the central heating system should be cleaned and flushed with cleaner to remove existing contaminants, flux residue and other installation debris which, if left, can cause damage to the new radiator. Afterwards, treat the system with an inhibitor to ensure long term protection against corrosion and limescale. A comprehensive range of quality chemicals including inhibitors, cleaners, leak sealers and noise reducers that protect and maintain central heating systems can be obtained from: Sentinel Performance Solutions Ltd The Heath Business & Technical Park, Runcorn, Cheshire WA7 4QX Tel: 01928 588 330 (UK) www.sentinel-solutions.net Fernox - Cookson Electronics, Forsyth Road, Sheerwater, Woking, Surrey GU21 5RZ www.fernox.com Pressure drops 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:35 Page 129 Stelrad LST Range Standard K1 50 Δt (75/65/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm UIN 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 145000 145001 145002 145003 145004 145005 145006 145007 145024 145025 145026 145027 145028 145029 145030 145031 145048 145049 145050 145051 145052 145053 145054 145055 P+ Heat output Watts Btu/hr 1 196 293 391 489 587 685 782 880 290 435 580 725 870 1015 1160 1305 365 548 730 913 1096 1278 1461 1643 145008 145009 145010 145011 145012 145013 145014 145015 145032 145033 145034 145035 145036 145037 145038 145039 145056 145057 145058 145059 145060 145061 145062 145063 669 1000 1334 1668 2003 2337 2668 3003 989 1484 1979 2474 2968 3463 3958 4453 1245 1870 2493 3115 3740 4361 4985 5606 UIN K2 Heat output Watts Btu/hr 284 426 568 710 852 994 1136 1278 386 580 773 966 1159 1352 1546 1739 501 751 1002 1252 1502 1753 2003 2254 969 1454 1938 2423 2907 3392 3876 4361 1317 1979 2637 3296 3955 4613 5275 5933 1709 2562 3419 4272 5125 5981 6837 7691 UIN 145016 145017 145018 145019 145020 145021 145022 145023 145040 145041 145042 145043 145044 145045 145046 145047 145064 145065 145066 145067 145068 145069 145070 145071 Heat output Watts Btu/hr 348 522 696 870 1044 1218 1392 1566 478 717 956 1195 1434 1673 1912 2151 615 922 1230 1537 1844 2152 2459 2767 1187 1781 2375 2968 3562 4156 4750 5343 1631 2446 3262 4077 4893 5708 6524 7341 2098 3146 4197 5244 6295 7343 8393 9441 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). K1 40 Δt (65/55/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 UIN P+ Heat output Watts Btu/hr 145000 147 145001 219 145002 292 1 145003 366 145004 439 145005 512 145006 585 145007 658 145024 217 145025 325 145026 434 145027 542 145028 651 145029 759 145030 868 145031 976 145048 273 145049 410 145050 546 145051 683 145052 820 145053 956 145054 1093 145055 1229 500 748 998 1248 1498 1748 1996 2246 740 1110 1480 1850 2220 2590 2961 3331 932 1399 1863 2330 2797 3262 3729 4193 UIN 145008 145009 145010 145011 145012 145013 145014 145015 145032 145033 145034 145035 145036 145037 145038 145039 145056 145057 145058 145059 145060 145061 145062 145063 K2 Heat output Watts Btu/hr 212 319 425 531 637 744 850 956 289 434 578 723 867 1011 1156 1301 375 562 749 936 1123 1311 1498 1686 725 1087 1450 1812 2174 2537 2899 3262 985 1480 1973 2465 2958 3451 3946 4438 1279 1917 2557 3195 3833 4474 5112 5753 UIN 145016 145017 145018 1 145019 145020 145021 145022 145023 145040 145041 145042 145043 145044 145045 145046 145047 145064 145065 145066 145067 145068 145069 145070 145071 Heat output Watts Btu/hr 260 390 521 651 781 911 1041 1171 358 536 715 894 1073 1251 1430 1609 460 690 920 1150 1379 1610 1839 2070 888 1332 1776 2220 2664 3109 3553 3997 1220 1830 2440 3050 3660 4270 4880 5490 1570 2353 3139 3923 4706 5492 6276 7062 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 130 Stelrad LST Range Standard K1 30 Δt (55/45/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm UIN 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 560 760 960 1160 1360 1560 1760 1960 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 145200 145201 145202 145203 145204 145205 145206 145207 145208 145209 145210 145211 145212 145213 145214 145215 145216 145217 145218 145219 145220 145221 145222 145223 P+ Heat output Watts Btu/hr 101 151 201 252 302 353 403 453 149 224 299 373 448 523 597 672 188 282 376 470 564 658 752 846 344 515 687 859 1031 1204 1374 1546 510 764 1019 1274 1529 1784 2038 2293 641 963 1283 1604 1926 2246 2567 2887 UIN K2 Heat output Watts Btu/hr 145248 146 145249 219 145250 293 145251 366 145252 439 145253 512 145254 585 145255 658 145256 199 145257 299 145258 398 145259 497 145260 597 145261 696 145262 796 145263 896 145264 258 145265 387 145266 516 145267 645 145268 774 145269 903 145270 1032 145271 1161 499 749 998 1248 1497 1747 1996 2246 678 1019 1358 1697 2037 2376 2717 3056 880 1320 1761 2200 2639 3080 3520 3961 Heat output Watts Btu/hr UIN 145224 145225 145226 145227 145228 145229 145230 145231 145232 145233 145234 145235 145236 145237 145238 145239 145240 145241 145242 145243 145244 145245 145246 145247 179 269 358 448 538 627 717 806 246 369 492 615 739 862 985 1108 317 475 633 792 950 1108 1266 1425 611 917 1223 1529 1834 2140 2446 2752 840 1260 1680 2100 2520 2940 3360 3780 1081 1620 2161 2701 3240 3781 4321 4862 EN 442 Certification Data - CETIAT tested in accordance with BS EN 442 Type Casing Height Emitter Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) Weight (kg/m) Water Contents (l/m) K1 500 300 489 1.19 2.09 17.80 1.89 650 450 725 1.25 3.37 23.50 2.57 P+ 800 600 913 1.34 4.66 29.40 3.25 500 300 710 1.24 2.44 22.70 3.70 650 450 966 1.27 3.84 30.72 5.15 K2 800 600 1252 1.31 5.24 38.40 6.60 500 300 870 1.27 3.51 24.40 3.70 650 450 1195 1.30 5.62 33.30 5.15 800 600 1537 1.32 7.74 42.50 6.60 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 131 LST Standard wall fixings & bracket positions All dimensions in mm. Inches in brackets. 195 (7.67) 134 (5.27) 102 (4.01) 100 (3.93) Casing Height 500 650 800 Casing Height Casing Length 560 760 960 24 (0.94) 195 (7.67) 165 (6.49) 165 (6.49) Casing Length Casing Height 500 650 800 24 (0.94) 134 (5.27) B 475 575 675 775 875 195 (7.67) 102 (4.01) A 445 545 645 745 845 Casing Height Casing Length 1160 1360 1560 1760 1960 A 100 (3.93) 195 (7.67) 165 (6.49) 165 (6.49) B Casing Length 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 132 LST Standard connection options All dimensions in mm. Inches in brackets. 119 (4.68) 25 (0.98) A 250 400 550 A Casing Height 500 650 800 Casing Height 132 (5.19) LST Standard piping options 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 133 Stelrad LST Range Plus Vertical 50 Δt (75/65/20°C) Casing Height Casing Length mm Emitter Height mm Emitter Length mm UIN 2110 560 660 760 1800 1800 1800 400 500 600 142241 142242 142243 Heat output Watts Btu/hr 1271 1588 1855 4336 5418 6329 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). W LST Plus Vertical installation instructions All dimensions in mm. Inches in brackets. Present casing and bottom bracket to the wall and mark drill hole positions. Fit pipework and valve connections to the radiators. 560, 660, or 760 195 (7.68) 195 (7.68) radiator indentation left Looking to the front of the radiator radiator indentation right 2086.5 (82.15) Looking to the front of the radiator L R indentation 1544 (60.79) 2x Bottom view 257 (10.12) 459 (18.07) 404 (15.91) 17.5 (0.69) 359 (14.13) 165 (6.50) 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 134 LST Plus Vertical connection options All dimensions in mm. Inches in brackets. 132 (5.19) radiator indentation left Looking to the front of the radiator radiator indentation right Looking to the front of the radiator 243 (9.56) indentation Casing Length A 560 344 660 444 760 544 50 (1.96) A Casing length Bottom view 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 141 Stelrad LST Range i Plus K1 50 Δt (75/65/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm UIN 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 145200 145201 145202 145203 145204 145205 145206 145207 145208 145209 145210 145211 145212 145213 145214 145215 145216 145217 145218 145219 145220 145221 145222 145223 P+ Heat output Watts Btu/hr 1 196 293 391 489 587 685 782 880 290 435 580 725 870 1015 1160 1305 365 548 730 913 1096 1278 1461 1643 145248 145249 145250 145251 145252 145253 145254 145255 145256 145257 145258 145259 145260 145261 145262 145263 145264 145265 145266 145267 145268 145269 145270 145271 669 1000 1334 1668 2003 2337 2668 3003 989 1484 1979 2474 2968 3463 3958 4453 1245 1870 2493 3115 3740 4361 4985 5606 UIN K2 Heat output Watts Btu/hr 284 426 568 710 852 994 1136 1278 386 580 773 966 1159 1352 1546 1739 501 751 1002 1252 1502 1753 2003 2254 969 1454 1938 2423 2907 3392 3876 4361 1317 1979 2637 3296 3955 4613 5275 5933 1709 2562 3419 4272 5125 5981 6837 7691 UIN 145224 145225 145226 145227 145228 145229 145230 145231 145232 145233 145234 145235 145236 145237 145238 145239 145240 145241 145242 145243 145244 145245 145246 145247 Heat output Watts Btu/hr 348 522 696 870 1044 1218 1392 1566 478 717 956 1195 1434 1673 1912 2151 615 922 1230 1537 1844 2152 2459 2767 1187 1781 2375 2968 3562 4156 4750 5343 1631 2446 3262 4077 4893 5708 6524 7341 2098 3146 4197 5244 6295 7343 8393 9441 ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you have a low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer). K1 40 Δt (55/45/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 UIN P+ Heat output Watts Btu/hr 145200 147 145201 219 145202 292 145203 366 145204 439 145205 512 145206 585 145207 658 145208 217 145209 325 145210 434 145211 542 145212 651 145213 759 145214 868 145215 976 145216 273 145217 410 145218 546 145219 683 145220 820 145221 956 145222 1093 145223 1229 500 748 998 1248 1498 1748 1996 2246 740 1110 1480 1850 2220 2590 2961 3331 932 1399 1863 2330 2797 3262 3729 4193 UIN 145248 145249 145250 145251 145252 145253 145254 145255 145256 145257 145258 145259 145260 145261 145262 145263 145264 145265 145266 145267 145268 145269 145270 145271 K2 Heat output Watts Btu/hr 212 319 425 531 637 744 850 956 289 434 578 723 867 1011 1156 1301 375 562 749 936 1123 1311 1498 1686 725 1087 1450 1812 2174 2537 2899 3262 985 1480 1973 2465 2958 3451 3946 4438 1279 1917 2557 3195 3833 4474 5112 5753 UIN 145224 145225 145226 145227 145228 145229 145230 145231 145232 145233 145234 145235 145236 145237 145238 145239 145240 145241 145242 145243 145244 145245 145246 145247 Heat output Watts Btu/hr 260 390 521 651 781 911 1041 1171 358 536 715 894 1073 1251 1430 1609 460 690 920 1150 1379 1610 1839 2070 888 Btu/hr 1332 1776 2220 2664 3109 3553 3997 1220 1830 2440 3050 3660 4270 4880 5490 1570 2353 3139 3923 4706 5492 6276 7062 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 142 Stelrad LST Range i Plus K1 30 Δt (55/45/20°C) Casing Height 500 650 800 Casing Length mm Emitter Height mm Emitter Length mm UIN 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 650 850 1050 1250 1450 1650 1850 2050 300 300 300 300 300 300 300 300 450 450 450 450 450 450 450 450 600 600 600 600 600 600 600 600 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 400 600 800 1000 1200 1400 1600 1800 145200 145201 145202 145203 145204 145205 145206 145207 145208 145209 145210 145211 145212 145213 145214 145215 145216 145217 145218 145219 145220 145221 145222 145223 P+ Heat output Watts Btu/hr 101 151 201 252 302 353 403 453 149 224 299 373 448 523 597 672 188 282 376 470 564 658 752 846 344 515 687 859 1031 1204 1374 1546 510 764 1019 1274 1529 1784 2038 2293 641 963 1283 1604 1926 2246 2567 2887 UIN K2 Heat output Watts Btu/hr 145248 146 145249 219 145250 293 145251 366 145252 439 145253 512 145254 585 145255 658 145256 199 145257 299 145258 398 145259 497 145260 597 145261 696 145262 796 145263 896 145264 258 145265 387 145266 516 145267 645 145268 774 145269 903 145270 1032 145271 1161 499 749 998 1248 1497 1747 1996 2246 678 1019 1358 1697 2037 2376 2717 3056 880 1320 1761 2200 2639 3080 3520 3961 Heat output Watts Btu/hr UIN 145224 145225 145226 145227 145228 145229 145230 145231 145232 145233 145234 145235 145236 145237 145238 145239 145240 145241 145242 145243 145244 145245 145246 145247 179 269 358 448 538 627 717 806 246 369 492 615 739 862 985 1108 317 475 633 792 950 1108 1266 1425 611 917 1223 1529 1834 2140 2446 2752 840 1260 1680 2100 2520 2940 3360 3780 1081 1620 2161 2701 3240 3781 4321 4862 EN 442 Certification Data - CETIAT tested in accordance with BS EN442 Type Casing Height Emitter Height W/m at 75/65/20 n-coefficients Heated Surface Area (m²/m) Weight (kg/m) Water Contents (l/m) K1 500 300 489 1.19 2.09 17.80 1.89 650 450 725 1.25 3.37 23.50 2.57 P+ 800 600 913 1.34 4.66 29.40 3.25 500 300 710 1.24 2.44 22.70 3.70 650 450 966 1.27 3.84 30.72 5.15 K2 800 600 1252 1.31 5.24 38.40 6.60 500 300 870 1.27 3.51 24.40 3.70 650 450 1195 1.30 5.62 33.30 5.15 800 600 1537 1.32 7.74 42.50 6.60 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 143 LST i Plus wall fixings and bracket positions 134 (5.27) 100 (3.93) Casing Height 500 650 800 270 (10.63) 102 (4.01) Casing Length 650 850 1050 Casing Height 270 (10.63) 24 (0.94) All dimensions in mm. Inches in brackets. 237 (9.33) 237 (9.33) Casing Length 24 (0.94) Casing Height 500 650 800 134 (5.27) B 448 548 648 748 848 100 (3.93) A 415 515 615 715 815 Casing Height Casing Length 1250 1450 1650 1850 2050 270 (10.63) A 102 (4.01) 270 (10.63) 237 (9.33) B 237 (9.33) Casing Length 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 144 LST i Plus connection options All dimensions in mm. Inches in brackets. 25 (0.98) A Casing Height 87 (3.42) Casing Height A 500 250 650 400 800 550 35 (1.37) 60 (2.36) 50 (1.96) 87 (3.42) Control on left-hand side 35 (1.37) 50 (1.96) Pipe configurations 120 (4.72) 132 (5.19) Control on right-hand side 16970_Stelrad Radiator Book 2015_Layout 1 23/04/2015 15:36 Page 145 LST Range Components LST Standard front case view. LST Standard inside the casing showing the emitter. LST Standard emitter, showing high level valve option (valve not included). LST Standard circular knockout for TRV. Oblong knockout for pipe. LST Plus inside the casing showing the emitter. LST Vertical front case view. LST i Plus front case view. LST i Plus inside the casing showing the emitter. LST Plus front case view. LST Plus and LST i Plus Components Optional cover cap to discourage unauthorised tampering. An arthritic adaptor is supplied as standard for special needs environments. Accommodated within the casing, the Stelrad LST Plus emitter, with TBSE valve arrangement and 2 x 1⁄2" BSP connections as standard. Connection arrangement bottom. Connection arrangement top. The Stelrad STARS Heatloss Calculator contains an inbuilt U value calculator. Save time and effort by using the Stelrad STARS program - the perfect solution for accurate sizing and design flexibility. www.starsapp.co.uk Includes Danfoss RA-2000 TRV and copper pipe configuration. The remote sensing thermostatic valve gives accuracy of operation and the limiting device is completely hidden to prevent the maximum temperature being exceeded. Safety Series Stelrad House Marriot Road Mexborough Rotherham S64 8BN www.stelrad.com [email protected] 01709 578 950 Merchant Enquiries Telephone 0844 543 6200