E2R PGC program User manual User manual no.: ITKU-81-01-09-13-PL MANUFACTURER OF ELECTRONIC WEIGHING EQUIPMENT RADWAG, 26 – 600 Radom, 28 Bracka Street POLAND phone +48 48 38 48 800, phone/fax. +48 48 385 00 10 Sales Department +48 48 366 80 06 www.radwag.com Table of CONTENTS 1. GENERAL INFORMATION .................................................................................. 4 1.1. Intended use ................................................................................................. 4 1.2. Instruments compatible with E2R PGC......................................................... 7 2. SOFTWARE STARTUP ....................................................................................... 8 2.1. Adding the first user ...................................................................................... 8 2.2. Logging in ................................................................................................... 10 3. MAIN WINDOW .................................................................................................. 10 3.1. Software workpane ..................................................................................... 12 3.1.1. Data sorting......................................................................................... 12 3.1.2. Data filtering ........................................................................................ 12 3.1.3. Filter Editor.......................................................................................... 14 4. SOFTWARE SETTINGS .................................................................................... 18 4.1. Database .................................................................................................... 18 4.2. Authorization and User Groups................................................................... 18 4.3. Service settings .......................................................................................... 22 4.4. User settings ............................................................................................... 22 4.5. Software layout modification ....................................................................... 24 4.6. Modules ...................................................................................................... 26 4.7. Language selection..................................................................................... 26 4.8. Logging out ................................................................................................. 27 4.9. Exiting E2R ................................................................................................. 27 5. FILES.................................................................................................................. 28 5.1. PGC Products ............................................................................................. 28 5.1.1. Adding/editing product ........................................................................ 29 5.1.2. Deleting product .................................................................................. 31 5.1.3. Product search and filtering ................................................................ 32 5.1.4. Products reports.................................................................................. 32 5.2. Operators .................................................................................................... 33 5.2.1. Deleting operator ................................................................................ 33 5.2.2. Adding/ editing operator ...................................................................... 34 5.2.3. Operator search and filtering .............................................................. 35 5.2.4. Operators reports ................................................................................ 35 6. E2R PGC ............................................................................................................ 36 6.1. PGC controls .............................................................................................. 36 6.1.1. Basic Control Report ........................................................................... 37 6.1.2. Detailed Control Report ...................................................................... 39 6.1.3. Control graph ...................................................................................... 40 6.1.4. Comments........................................................................................... 41 2 6.1.5. Deleting report .................................................................................... 41 6.2. Average PGC tares ..................................................................................... 42 6.3. PGC weighments ........................................................................................ 44 6.3.1. Report for product ............................................................................... 45 6.3.2. Report for batch number ..................................................................... 45 6.3.3. Report for scale................................................................................... 46 6.3.4. Reports headers ................................................................................. 46 6.3.5. Weighments graph.............................................................................. 47 7. TOOLS ............................................................................................................... 48 7.1. Measuring devices on-line view .................................................................. 48 7.1.1. Window layout. ................................................................................... 52 7.1.1.1. The layout...................................................................................... 53 7.1.2. Connecting and disconnecting with the server ................................... 54 7.1.3. Server ................................................................................................. 55 7.1.3.1. Restart Local Synchronizer ........................................................... 56 7.1.3.2. Send Messages to Scale............................................................... 56 7.1.4. Symbol and status of measuring devices in E2R Manager ................ 57 7.1.5. Connection restart and measuring device update in E2R Manager ... 58 7.1.6. PGC monitoring symbol. ..................................................................... 58 7.1.7. Sending a message to a measuring device ........................................ 59 7.1.8. Controlling the measuring devices ...................................................... 60 7.2. Measuring device restart............................................................................. 63 3 1. GENERAL INFORMATION 1.1. Intended use E2R SYSTEM offers complex operation of production processes connected with weighment processes at different stages. Thanks to a modular construction, this software is very flexible and can easily match a profile, specificity and needs of a company, as well as an individual client’s needs. E2R SYSTEM E2R PGC is a computer system which consists of E2R SYSTEM software and RADWAG measuring devices. It allows both, synchronization of databases of operators and products, and recording weighments and PGC controls executed with the use of devices linked in ETHERNET network. The system enables monitoring of measuring devices in a real time, as well as control in order to start or stop supervision of a computer. Measuring devices network might comprise one or several instrument types. 4 ETHERNET Diagram of E2R PGC system in Ethernet network E2R PGC system enables a shortened and detailed PGC control report, PGC control graph and statistics report with a graph for a particular product. Such a graph is based on weighments collected from balances during determined period of time. E2R PGC module, as well as other E2R SYSTEM modules, is a multi-stand software and can cooperate with several instrumentss and computers. Every device is an independent weighing stand and it can work without interruptions during a network or server failure. Information about control is regularly sent to a computer program. All messages concerning control are displayed on a measuring device and a computer at the same time. The control reports are saved to the measuring device and recorded to the software database. Scale operator decides about the control startup. This makes the operator independent of the software. The software regularly stores data which is registered in the software database. 5 Control activated with the use of a measuring device is automatically finished after a determined number of packages has been controlled. To set controlled packages number operator uses software options. When the control is over, it is possible to generate a basic and detailed report containing all necessary information about its result. The user can assess the quality of packaged goods on the basis of gathered data and check their compatibility with: • an act ‘On Pre-packaged Goods’ of 7th May 2009 on Pre-packaged Goods (Journal of Laws of 2009, No. 91, item 740), regarding quantity control of packaged goods – by a random selection of measuring results and sending them to the procedure of packaged goods control, conformable with the European Directives and the board directives. • company internal quality control system, which can be modified in terms of: - number of batches, - negative values of errors T, - positive values of errors T, - a coefficient for calculation of the acceptable average threshold. There are two possibilities of control activation: • Started by a measuring device operator who sends a message about the control startup to the software, • Started by a software operator who selects a measuring device on which the control will take place, a confirmation on the measuring device is required. Other function of the software: • Automation of the control process, • Operator mistakes control, • Possibility of two platform scales operation, • Defining access rights to particular functions of the software, • Printout of control reports, • Printout of statistics, • Reports and statistics control from a freely chosen site of a company network. Software enables control according to the selected algorithms: • Control with an average tare Non-destructive average tare • Control with a variable tare 6 Non-destructive empty – full Destructive full – empty Destructive empty – full Caution: 1. Because of software updates, this manual and the software might differ slightly. 2. RADWAG does not take responsibility for: • software operation results and possible errors caused by an inadequate usage. • data protection and its loss caused by software/computer inadequate usage and lack of spare copy. 3. RADWAG does not store any archival software versions therefore the company cannot make them accessible in case of loss; update to the latest version of E2R SYSTEM will be required if such situation occurs. 1.2. Instruments compatible with E2R PGC Because of the adopted protocol of data exchange, E2R PGC is compatible only with RADWAG measuring devices. Instruments series accordant with the software are as follows: WLY, WPY, HTY, 3Y. 7 Set appropriate working parametres for each measuring device of network in order to ensure an expected measuring accuracy and a proper cooperation with the software. Please read a user manual of a relevant measuring device to find out how to conduct procedure of setting its working parametres. 2. SOFTWARE STARTUP To activate the software you can use either a desktop shortcut or menu: START/PROGRAMS/RADWAG/E2R SYSTEM/E2R SYSTEM 2.1. Adding the first user On the first startup, you will see a message that there are no users in the database. On pressing OK, the software will automatically open a dailog window allowing you to add a new user. 8 Fill in the scale code/ login, password and name fields, next go to Group field and select Administrator option. Caution: Remember that the first user must be a user with administrator authorities in order to avoid problems with the software options setup. Fill in all necessary fields, remember that scale code functions as login. Save changes and close the window. Press OK to confirm the program restart. 9 2.2. Logging in On the software startup, you need to log in. In the log in box insert Login/ Scale code and the operator’s Password. Confirm the changes pressing OK and wait for the main window of a program to be opened. 3. MAIN WINDOW After log-in procedure, the software main window opens: 10 The main window features 4 areas: • Top Toolbar, • Navigation Bar (working area), • Status Bar, • Workpane (preview area). Top Toolbar contains program settings, logout and exit button. Navigation Bar contains program functions and modules. Status bar displays information about a software version, a logged in user and his access level, active mode and software licence. 11 Dialog windows and dialog boxex of modules are displayed in a workpane. To open a given window and read its data and information the user must press any button of a Navigation Bar. 3.1. Software workpane Information displayed in a workpane is taken from database. Weighments may be sorted and filtered. Filtering mechanisms enable search for a specific kind of information of a given column. Sorting mechanisms (grouping) allow to summarize data for a given column. 3.1.1. Data sorting Workpanes of all available modules allow to freely sort displayed data. In order to group the data select a given column header and drag it to the place marked with a red square in the picture. The selected header will be displayed as a button (its name visible for the user). Press the button once to sort the list lowest to highest or vice versa. 3.1.2. Data filtering To get to additional filtering options press a pictogram placed on the right side of each column. To see the pictogram place a mouse cursor over the chosen column. Upon clicking right mouse button drop-down menu of sorting options appears. 12 Where: Best Fit A-Z sorting Z-A sorting Clears filter effect Groups data by a selected column Hides fast grouping area Deletes a selected column Activates column customization (the user may add new columns) Adjusts column width Best Fit (all columns) Adjusts all columns width Filter Editor… Show Find Panel Advanced filter options Activates one filter addressed to all columns Hides all columns filtering window Sort Ascending Sort Descending Clear Sorting Grup By This Collumn Hide Group By Box Remove This Column Column Chooser Hide Auto Filter Row 13 In the bottom part of a workpane there is a data filter allowing to generate five basic statistics for a given column. Place the mouse cursor over workpane footer and press right mouse button to select an appropriate statistics type. Basic statistics: Sum Min Sum of all values of a given column The lowest value of a given column Max Count Average The highest value of a given column Number of rows of a given column Average value of a given column data Depending on data type there is a possibility of choosing all 5 options for a given column. 3.1.3. Filter Editor button is displayed in the bottom part of a Upon setting a filter, workpane. By means of this button Filter Editor window is activated where database data can be freely filtered. 14 Filter creator allows to set one or many filters, it provides the user with a precise data filtering and detailed reports. The user may set particular filter elements: a) Filter groups (and, or, not and, not or) Where: And All filter conditions must be fulfilled Or Any filter condition must be fulfilled Not and Displays records meeting all other requirements than those specified by filters Displays records meeting any other requirement than those specified by filters Allows to add new filter condition Not or Add condition Add group Clear all Allows to add new filter group (group may be filtered by many filter conditions) Deletes all filter conditions b) Filter conditions – determines what data is to be filtered and how: - selection of a column to be filtered 15 - selection of a filter range (method and range) Where: Equals Does not equal Is greater than Is greater than or equal to displays only these records of a given column that contain exact value displays all records of a given column that contain values different than exact value (opposite of “Equals” filter) displays all records of a given column that contain values greater than exact value displays all records of a given column that contain values greater than exact value or equal to it 16 Is less than Is less than or equal to Is between Is not between Does not contain Begins with Ends with Is like Is not like Is blank Is not blank Is any of Is none of displays all records of a given column that contain values lesser than exact value displays all records of a given column that contain values lesser than exact value or equal to it displays all records of a given column that contain values within a given value range displays all records of a given column that contain values outside a given value range displays all records of a given column that do not contain exact value displays all records of a given column where values begin with an exact value displays all records of a given column where values end with an exact value displays all records of a given column with values between given start value and end value, start and end value must be separated with “%” character displays all records of a given column with opposite values to those between given start value and end value, start and end value must be separated with “%” character displays all records of a given column with undetermined values (blank) displays all records of a given column with determined values (not blank) displays all records of a given column with collectively determined values (one or more precisely determined values) displays all records of a given column with values not specified in a set (one or more precisely determined values – opposite to “Is any of” filter) It is possible to precisely determine filter criterion of a given column, eg. if you want to get a result concerning product “Onion” than proceed as follows: “Product name – Equals – value: Onion”. Add another criterion by pressing “+” character located next to filter group if you want to find only specified weighments. Press Apply button to confirm configuration and activate filter. Bottom bar displays chosen filter configuration. 17 4. SOFTWARE SETTINGS Click button located in the top bar to activate Settings. 4.1. Database Use this option if you want to do the following: check connection with a database, change database localization when activating E2R on a spare computer, do a backup copy or run a saved on a server database. Dtabase has been described in a E2R SYSTEM service manual. 4.2. Authorization and User Groups Here access to program functions is set for each authorization group. Chart of authorization for scales-terminals: Authorization group Administrator Advanced Standard Basic WPW - PUEC41H Administrator Advanced Operator Standard Operator Standard Operator WLY, WPY - PUE7 Administrator Advanced Operator Standard Operator None HTY - HY Administrator Advanced Operator Standard Operator None 3Y Administrator Advanced Operator Standard Operator None TMX - PUE5 Administrator Advanced Operator Standard Operator Basic Operator Scales - Terminals 18 CAUTION! It is not recommended to edit or delete already created authorization groups since they are strictly related to authorization groups of a computer and measuring devices. By custom if any authorization group is modified or deleted the program restores it with a default name after computer restart. Group names can be modified, to do it contact RADWAG. To start authorization of users and groups click located in Settings menu. User groups are defined in Group bookmark. Where: Add Delete Save Adds users group Deletes users group Saves settings 19 button Access Rights bookmark stores codes and assigned to them names. Group Rights bookmark allows to set rights to program modules. 20 Select a given group out of Group drop-down menu to add or remove its rights. On the left there is a list of available functions for a given authorization group. It is possible to delete a chosen function in order to block access to it. On the right there is a list of unavailable functions for a given authorization group. It is possible to add a given function to the list on the left in order to make it accessible. Authorization modification with the use of arrows: Accessing all functions (for a given group), Accessing a function selected from a list on the right (for a given group), Blocking access to a function selected from a list on the left (for a given group), Blocking access to all functions (for a given group), 21 4.3. Service settings Press button to activate service settings. The button is located in Settings menu. Caution: Full access to service settings is available for RADWAG emploees only. 4.4. User settings Press button to activate user settings. The button is located in Settings menu. Company details bookmark: Company details Address Company name printed in PGC reports Company address printed in PGC reports 22 Automatic Log-off bookmark: Automatically log off after Automatic log off after defined number of minutes. 0 value deactivates this function. Automated Product Export bookmark: Automated Product Export Target place of control reports record. Does not apply to PGC module. 23 4.5. Software layout modification Press button to change colour of program graphic interface and select chosen option. Possible compositions: DevExpress Style DevExpress Dark style Metropolis VS2010 24 Seven Classic Office 2010 Black Office 2010 Blue Office 2010 Silver 25 4.6. Modules In order to swap beetwen modules go to Settings menu and press button. Select a given module out of the list, next press “Set the selected module” button. After a given module has been set confirm the following message by pressing OK. E2R SYSTEM service manual describes modules activation process in details. 4.7. Language selection It is possible to swap between languages. To select a desired language move up or down the drop-down menu. 26 Where: PL EN Polish English DE ES RU German Spanish Russian 4.8. Logging out Press button to log out. If you still want to work with E2R fill in the fields of a dialog window with the user Login and Password. Press Log in button to confirm. 4.9. Exiting E2R Press button to close E2R program. Dialog box with confirmation message will be displayed. To leave the program press Yes, to get back to the main window press No. 27 5. FILES E2R PGC features the following card files: • PGC Products, • Operators. Card files may be edited on a computer, using measuring devices for card files edition is impossible. Newly added product is automatically send to the measuring devices in a real time. Such an action takes place also upon edition of an already existing product. Newly added operator is send to the measuring devices after scaleto execute connection computer connection restart. Press restart. Such an action takes palce also upon edition of an operator already exixting in a computer card file. 5.1. PGC Products PGC Products file allows operation on controlled products (packagings) database. To activate PGC products module click PGC products link located in a Navigation Bar. PGC Products workpane: 28 5.1.1. Adding/editing product Press button to add a new product to the file. Press button to edit already added products. PGC Product editing window: Where: Product code Product name (contraction) Code * Name * Description Name) EAN code (Full Description, full name of a product Product EAN code Internal code Product number accordant with product list of products and services classification Company internal product code Nominal mass (Qn) * Nominal mass or volume of a product Unit Product unit: [g] or [ml] PCGS 29 Tare value (packaging mass) for control of porducts with constant tare given in [g] (concerns „Nondestructive Average Tare” control) Drop-down menu of control type. possible choices: „Nondestructive Average Tare”, „Nondestructive Empty-Full”, “Destructive FullEmpty”, “Destructive Empty-Full” Product density (field active for unit [ml]), 3 3 recommended values range 0,1g/cm - 5g/cm . Batch portion number (number of packaged products measurements followed by measurements of empty packagings of these products). Fill in the field for all types of control except for „Nondestructive Average Tare” Declaration of controlled batch size, in reference to this size number of control measurements is calculated. This value may be changed after control has started by operators other than Basic Operator. Default value is 100. Recommended value range is 1 - 20 000 Enables advanced parameters of internal control. Tare * PGC mode Density Batch portion Batch size Additional thresholds (*) – mandatory fields, they must be filled in when adding and editing a product record. • List of data for internal criteria Qquantity packages of Error value [-T1] Error value [+T1] Quantity of smaple [Qn-T1] dis. Declaration of number of packagings needed for estimation of an average tare (for „Nondestructive Average Tare”) Error value of marginal negative T (-T) given in unit of product nominal mass Qn. Measurements lower than value of Qn-T are regarded as valid. Error value of marginal positive T (+T) given in unit of product nominal mass Qn. Measurements higher than value of Qn+T are regarded as valid. If 0 value is filled in than number of + errors are not taken into account. Number of negative errors (–T) of a tested sample which disqualifies control 30 Quantity of smaple [Qn+T1] dis. Quantity of smaple [Qn-2T1] dis. Quantity of smaple [Qn-2T1] dis. Apply values of permissible average limit values Sample quantity Factor value Wk - | Qn-s Factor value Wk + | Qn+s Average limit value - Average limit value + Number of positive errors (+T) of a sample which disqualifies control Number of negative errors (–2T) of a sample which disqualifies control Number of positive errors (+2T) of a sample which disqualifies control Mode of calculation of average limit (constant or automatic). tested tested tested value Value of product sample quantity, it determines number of packaging measurement independently from batch quantity. Multipier of standard deviation for value of average limit (negative) calculated automatically Multipier of standard deviation for value of average limit (positive) calculated automatically Value of average limit (negative) of a tested sample (concerns value of average limit as “constant”) Value of average limit (positive) of a tested sample (concerns value of average limit as “constant”) Upon filling/editing requested product data press save settings. button to 5.1.2. Deleting product Press button to remove a selected product from file. Wait to see a dialog box and press Yes to confirm. If database contains weighments of a product which is to be deleted than instead of being removed it will be set as an archival product. 31 Archival products are not displayed on measuring devices. 5.1.3. Product search and filtering Each product stored in a system may be searched by name appropriate for a given column. Upon entering product data in a selected column list of products meeting the given criteria is displayed. Press form filtering. button, located in Product workpane, to prevent program 5.1.4. Products reports Press button, located in Product workpane, to geneate products list report. The report may be printed on a printer, sent via e-mail or saved to file. Quick launch bar is available in a preview window of a generated report. Basic quick launch bar functions: quick printout with the use of default printer possibility of saving and reopening of a printout in a dedicated, for this kind of report, file format 32 printout export to numerous file formats: PDF, HTML, MHT, RTF, Excel, CSV, Text, Picture. 5.2. Operators Operators file enables operation on progam users database. All users stored in a database can log in to both, computer program and a measuring device. To activate operators module click Operators link located in a Navigation Bar. Operators workpane: Operators workane alows user to add, delete, modify operator profiles and their authorization. 5.2.1. Deleting operator Press button to remove a selected operator from file. Wait to see a dialog box and press Yes to confirm. 33 Deletion of an operator is impossible if database contains weighments executed by this operator. In order to delete the chosen operator, beforehand every single weighment executed by him/her must be removed. CAUTION! Removing operator weigments results in lack of possibility of generationg their report. Another possibility of removing an operator is to edit a given operator and tick box Archive, the operator will not be displayed on measuring devices but it will be possible to generate reports from all saved by him/her weighments. 5.2.2. Adding/ editing operator Press button to add a new operator to the file. Press button to edit already added operator. Operators editing window: 34 Where: Code / Login * Password * First name and last name * Group * Archive Operator’s scales code, login Operator’s password Operator’s first name and last name Authorization group, four basic groups are available: Administrator, Advanced, Standard and Basic. User authorization settings for a specified group are to be found in program settings. Determining operator as an archive one, field must be deselected for an active operator (*) - mandatory fields, they must be filled in when adding and editing an operator record. Upon filling/editing requested operatordata press save settings. button to 5.2.3. Operator search and filtering Each product stored in a system may be searched by name or phrase appropriate for a given column. Llist of products meeting the given criteria is displayed upon entering product data in a selected column. Press form filtering. button, located in Product workpane, to prevent program 5.2.4. Operators reports Press button, located in Operators workpane, to geneate operators list report. The report may be printed on a printer, sent via e-mail or saved to file. 35 Quick launch bar is available in a preview window of a generated report. Basic quick launch bar functions: quick printout with the use of default printer possibility of saving and reopening of a printout in a dedicated, for this kind of report, file format printout export to numerous file formats: PDF, HTML, MHT, RTF, Excel, CSV, Text, Picture. 6. E2R PGC E2R PGC offers control results presented in a form of PGC control reports, tare control reports and statistics reports. 6.1. PGC controls PGC controls function enables generation of : • Basic PGC controls report, • Detailed PGC controls report, • Report with a graph of PGC controls, • Summary report from a determined time period, • Shift reports. To activate PGC controls module click PGC controls link located in a Navigation Bar. Set basic data filter in order to search for an appropriate control. 36 PGC control workpane: Where: Control report Detailed control report Control graph Comments Refresh Delete report General PGC control report Detailed PGC control report with itemized weighments Report with PGC control graph Adding and editing commends of a selected PGC control, Update of executed PGC control list Cancelling a selected PGC control 6.1.1. Basic Control Report To generate basic report without itemised weighments select a demanded button. PGC control out of a list and click 37 Example of a PGC control report 38 6.1.2. Detailed Control Report To generate detailed report with itemised weighments select a demanded button. PGC control out of a list and click Example of a detailed PGC control report 39 6.1.3. Control graph To generate detailed report with graph select a demanded PGC control out button. of a list and click Example of a PGC control report with graph 40 6.1.4. Comments To add comments to a demanded PGC control select it out of a list and click button. Press button to confirm. Comments will be added to notes of basic control report, detailed report and report with a graph. 6.1.5. Deleting report To delete a report of a demanded PGC control select it out of a list and click button. Upon seeing the following message, which prevents from accidental deletion, press Yes to confirm. 41 6.2. Average PGC tares Average tare may be estimated before PGC control. PGC Aver. Tare module contains information needed to this process execution. To activate PGC Aver. Tare module click PGC Aver. Tare link located in a Navigation Bar. PGC Aver. Tare workpane: 42 Use data filter to set demanded data range and select control number before which average tare has been estimeted. Press button to generate a report. Example of a PGC average tare estimation report. 43 6.3. PGC weighments It is possible to prepare individual reports of a given user weighments stored in a database. All weighments executed in a specified time period may be added to reports, they may also be grouped and printed accordingly to stated criteria. To activate PGC weighments module click PGC weighments link located in a Navigation Bar. PGC weighments workpane: CAUTION! For a very large number of weighments and insufficient server resources it may turn out to be impossible to print reports concerning too long time period. 44 6.3.1. Report for product Example of a report for product 6.3.2. Report for batch number Example of a report for batch number 45 6.3.3. Report for scale Example of a report for scale 6.3.4. Reports headers Reports headers bookmark allows to change header of each of the three offered reports. Press Save button to preserve introduced changes. 46 6.3.5. Weighments graph It is possible to prepare report with a graph for a given product weighments that were executed in a specified time period and are stored in a database. Out of list located on the left set a product by name. A graph will be generated automatically in a graph window. 47 To generate report press button. Example of a report with a graph. 7. TOOLS 7.1. Measuring devices on-line view Measuring devices on-line view enables overview of measuring device state, especially currently executed controls. Control window displays information about: • Logged operator, • Controlled product, • Current control state, • Current control status (eg. Accepted) • Information about tare or products control, • Current warning status (approaching permissible limit), • Current control graph presentation, • Current gross mass, • Nominal net mass Qn, 48 • • • • • • • • • • • • • • • • • • • Product tare, Control product batch number, density [g/ml], criterion type (eg. legal), control type (eg. Non-destructive average tare), -T and +T errors values, Negative average limit and positive average limit, Sample number (1 or 2), Measurement of a sample, Measurements average, Standard deviation, Measurement sum, Minimal measurement, Maximal measurement, Qualifying -T number, Disqualifying -T number, Disqualifying +T number, Disqualifying -2T number, Disqualifying +2T number. All messages serve for information purposes therefore it is not possible to either save them or print. Upon „E2R SYSTEM” installation, a shortcut for E2R MANAGER on-line view is created in a start bar. To activate on-line view go to E2R SYSTEM program Navigation Bar, find Tools drop-dowm menu and click an appropriate link. 49 E2R Manager main window: 1 2 3 4 10 9 8 7 6 5 Description: 1 – Program name and version information, 2 – Program menu, 3 – Current mass and active platform number, 4 – Activation of PGC control window with detailed information, 5 – Bargraph of mass, Min, Ok, Max, 6 – Parameters of connection with database, 7 – Sending a message to a selected measuring device, 8 – PGC control symbol, 9 – Measuring device symbol and connection status, 10 – Measuring device name. Caution: When there is no connection between „E2R Manager” with Radwag Synchronizer or when Radwag Synchronizer is not activated this window will not be displayed. If the program is activated on more than one computer as a multi-stand software, only one on-line view is available at a time. 50 All crucial settings have been described in E2R service manual. PGC control window with details: 3 4 5 1 6 Description: 1 – PGC control graph, 2 – Graph values description, 3 – General information on control, 4 – PGC control summary, 5 – In-course PGC control criteria, 6 – PGC control statistics. 51 2 7.1.1. Window layout. Main window with an extended view (default layout): In order to swap to an extended view of a window go to View bookmark of E2R Manager program and select option Extended out of a drop-down menu list. Default window is an extended view window, which offers complete set of information about the measuring device. Main window with a standard view (simplified layout): 52 In order to swap to a standard view of a window go to View bookmark of E2R Manager program and select option Standard out of a drop-down menu list. Standard view window, offers information about measuring device status, active platform number and zero indication. 7.1.1.1. The layout Main window - automatic layout: In order to swap to an automatic layout go to View bookmark of E2R Manager program and select option Layout > Automatic out of a dropdown menu list. Automatic layout is a default layout, it enables selfregulated positioning of all measuring devices connected to the system. Main window - user layout: 53 In order to swap to a user layout go to View bookmark of E2R Manager program and select option Layout > User out of a drop-down menu list. User layout enables free positioning of all measuring devices windows. Main window – production lines layout: In order to swap to a production lines layout go to View bookmark of E2R Manager program and select option Layout > Production lines out of a drop-down menu list. Production lines layout displays a given production line devices in a row. This layout is positioned automatically. 7.1.2. Connecting and disconnecting with the server When willing to activate on-line view on other computer than currently operated one it must be first deactivated. Click Disconect button located in a menu bar. It doesn’t require exiting the program. 54 If the user wants to to activate on-line view he/she must click Conect button located in a menu bar. 7.1.3. Server Serwer menu contains connection restart option (Restart Local Synchronizer) and send message option (Send Messages to scale) Connection restart results in update of measuring device files and send message option allows to send message to all devices connected to a system. 55 7.1.3.1. Restart Local Synchronizer Restart Local Synchronizer is available when E2R SYNCHRONIZER is activated. It allows to reload server configuration and update meauring devices files. Select Restart Local Synchronizer located in Server menu. Press Yes to confirm server restart. Press OK to confirm the following message. 7.1.3.2. Send Messages to Scale It is possible to send one message to all measuring devices connected to the system. To do it go to Server menu and select Send Messages to Scale option out of a drop-down menu list. 56 Length of time for message display ranges from 3 to 3600 seconds. , To send message press To close window press . The following message will be displayed on all measuring devices connected to the system. 7.1.4. Symbol and status of measuring devices in E2R Manager Status informing about connection between a computer and a measuring device: Connection with a measuring device has been established, Correct settings of a measuring device, Correct measuring device settings in E2R Synchronizer. Connection with a measuring device has been established, Temporary lack of response from the device, Incorrect settings of a measuring device or incorrect measuring device settings in E2R Synchronizer. Connection with a measuring device has not been established, Measuring device has been turned off or connection has been lost, Incorrect settings of a measuring device or incorrect measuring device settings in E2R Synchronizer. 57 7.1.5. Connection restart and measuring device update in E2R Manager All files edited in E2R System, exept for product files are sent (updated) from computer to measuring devices only after E2R SYNCHRONIZER restart (connection restart or measuring device operation restart). During system operation it is possible to restart measuring device by double click of a chosen measuring device symbol in E2R Manager. After a while measuring device will connect to a system and all its files will be updated. 7.1.6. PGC monitoring symbol. Each measuring device window contains symbol informing about current state of PGC control. PGC control symbols description: Control activated. In-course control, positive. In-course control, negative. Control finished, positive. Control finished, negative. Control finished. 58 7.1.7. Sending a message to a measuring device System allows to send a message to one device. Select an appropriate measuring device and press button. Next select Send message option: Write the desired text in a dialog window, Set time And press button to confirm, button. or close the window by pressing The following message will be displayed on a selected measuring device. 59 7.1.8. Controlling the measuring devices System allows to control measuring device by means of computer. Available control functions: • Activation of control launch window, • Setting control parameters by means of computer, • Control activation by means of computer, • Control deactivation by means of computer. In order to select one of these funtions open window with control details and press button. Next choose one of its available options: Inducing window with PGC control parameters. Not logged operator will have to proceed to log in procedure. PGC control parameters selection, batch number is required. PGC control start, message is displayed on a measuring device if there is a load on it. Control deactivation, upon pressing this button control launch window is displayed on a measuring device. 60 • Activation of control launch window Control launch window opens upon pressing Select operator and write password. button. In a control parameters window select product, batch number and other control parameters. Depending on authorization it is possible to modify them. Control parameters selection may be performed on a computer. • Setting control parameters by means of computer Go to CONTROL menu to activate option. Next go to PGC control parameters window to select product by name, code, batch number or other parameters. 61 For precise and detailed information on products press . • Control activation by means of computer To activate PGC control by means of computer press button located in CONTROL menu. Measuring device will display window with detailed information on in-course control. Press button on a measuring device for confirmation. If upon PGC control activation there is a load on a weighing platform than message about error will be displayed on a measuring device. Control continuation will be impossible. 62 CAUTION! Zero the measuring device and remove the load from a weighing platform before control start. • Control deactivation by means of computer In-course control may be deactivted, to do it go to CONTROL menu and select button. The following message is displayed in order to eliminate accidental control deactivation. Press Yes to confirm. 7.2. Measuring device restart To carry out measuring device restart click Scale restart link located in a Navigation Bar. This action results in files update. 63 MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS RADWAG Balances & Scales 26 – 600 Radom Bracka 28 POLAND phone. +48 48 38 48 800 fax. + 48 48 385 00 10 Sales Department + 48 48 366 80 06 www.radwag.com 64