ClimaCheck Introduktion
Transcription
ClimaCheck Introduktion
ClimaCheck Enhance performance save energy and environment in air-conditioning refrigeration and heat pumps systems Field inspection unit Fixed installation ClimaCheck Sweden AB Klas Berglöf www.climacheck.com ClimaCheck Sweden • World leader in Performance Analysing for refrigeration and air-conditioning systems • Potential to reduce energy and peak load with 20-30% for air conditioning and refrigeration systems • Reduce failures - extend life of equipment – early warning • Distributors in 20+ countries – UL/CSA/CB certification • Work with leading universities/companies in many countries • Refrigeration Product of the Year 2009 in UK 2 15-20% of all electricity used for refrigeration, air-conditioning and heat pumps 3 International trend to push energy efficiency through legislation and green building certification In EU - Energy Performance in Building Directive (EPBD) Inspection of all AC-system with more than 12 kW cooling capacity The inspection is to include “an assessment of the air conditioning efficiency and the sizing compared to the cooling requirements of the building”. Advice is also to be provided to the users on “possible improvement or replacement of the air-conditioning system and on alternative solutions”. 4 13% of 164 systems were OK! Source: Master Thesis by John Arul Mike Prakash, , KTH Stockholm 2006 90 80 70 60 50 40 30 20 10 0 78 51 27 20 No Co nt ro ls ys te m Se co nd ar y flo w Ch ar ge e va lv n Ex pa ns io fa ul ts 4 3 Co m pr es so r Number of systems Representation of faults for all the sectors Inspections were planned and contractor informed Huge difference between theory and practice! 5 Huge variation in COP Source: Master Thesis by John Arul Mike Prakash, , KTH Stockholm 2006 % Variation in COP (vs.) Nominal capacity kW % variation in COP 10 0 -10 -20 -30 -40 0 200 400 600 Nominal capacity kW 6 800 1000 ClimaCheck performance analyses Unique innovative method – total visualisation of performance Flexible PC and Web based systems to document: Commissioning Performance inspection Continuous monitoring Preventive maintenance Trouble shooting Decision support – minimize warranty cost – optimisation – early warning and optimisation – reduce failure rate – optimise – avoid damage to product – expansion retrofit Any expert - independent or from supplier can analyse system Also used by 40+ manufacturer development and production test rigs 7 Do not retrofit without knowing what you retrofit! Pre-retrofit analyses Do not invest in poor systems that are failing Fixed system Establish baseline consumption R-22 Retrofit Post-retrofit analyses ClimaCheck optimisation Optimise Document performance Detect future deviation Easy to apply – to standard service “points” Electrical input 7 surface temperatures 2 pressures from service ports 9 Application of sensors to standard system (typically done in 20-30 minutes) • 2 pressures • 7 temperatures • 1 power input No information about system or compressor added 10 Simple Refrigeration Cycle P m condensation m Expansion m m compression m Vaporization h 11 Analyzes on the “standard” process Pressure 1. Low pressure and suction temp. Ideal Compression 3 2. High Pressure and discharge Temp. 3. High pressure and liquid temperature. Heat Capacity P HP Enthalpy Difference P LP Cooling Capacity 1 Power Energy Consumption Mass Flow = (Power consumption – heat losses) / Enthalpy Increase COP = Cooling Capacity / Power Energy Consumption Use the Theory for practical use on field 12 2 Enthalpy Theory Performance analysing using ”Black Box” perspective on compressor Enthalpy increase refrigerant Heat losses (relatively small and predictable) Electric energy input (e.g. Electric input = enthalpy increase + heat losses from shell) 13 What about error in the heat loss estimate? Conditions +5/50°C R407C T = 85°C T = +15°C 33kW Heat Loss % 5 7 Enthalpy Increase 48.5 48.5 Mass Flow Rate kg/s 0.653 0.641 Capacity kW 100 98.2 40% error in the Heat Loss results in <2% Capacity Error Key Results • • • • • • Cooling capacity (± 7% accuracy) Heating capacity (± 7% accuracy) COP (± 5% accuracy) Compressor efficiency Super heat and sub cooling Functionality of Control • Evaporation, Condenser pressure and temperature • UA and mean temperature differences in evaporator and condenser • Flow of secondary systems based on Capacity and temp. difference Listed are only key information – standard template consist of > 40 outputs allowing detailed analyses of each component 15 Inspections and monitoring Documentation of performance in refrigeration process is a prerequisite for efficiency and optimisation Stop assuming all is OK – look inside the “black box” 16 Global references in all sectors • Carrier Europe for Chiller optimisation performance inspections – Use portable Performance Analysers in all EU countries for Inspections and trouble shooting. • Carrefour, Metro supermarkets in Italy, TESCO, Sainsbury in UK – Saved 20-30% in pilot on 6 hypermarkets 2010 - now installed in 50+. • Johnson Control industrial contractor in Spain/Sweden/UK – Correct problems and improve efficiency in large industrial ammonia plants • Copeland Europe and Bitzer compressor manufacturers – Use ClimaCheck in trouble shooting and development work with their customers • DuPont and Solway refrigerant manufacturers – Use ClimaCheck to document retrofit projects • Several projects on-going in US, Australia, Middle East and India 17 Report from Carrier site inspection Carrier Performance Analyser Rapport från mätning Site: Anläggning: Datum: Tidpunkt start: Tidpunkt stopp: Title COOL_EWT COOL_LWR COND_EWT COND_LWT POWER KW COOLING CAPACITY EER HEATING CAPACITY COP TrioPlast, Landskrona KM11 20100426 11:57 13:17 Measured Value 9.5 5.7 35.6 45.1 350.2 1177.4 3.36 1503.2 4.29 °C °C °C °C kW kW kW Nominal Data 9.5 5.7 35.6 45.1 342.0 1160.0 3.39 1484.0 4.41 Deviation 0.00 0.00 0.00 0.00 8.20 17.40 0.03 19.20 0.12 Comment K K K K kW kW kW ap 2,3 % negativ deviation ap 1.5 % positiv deviation ap 1.3 % positiv deviation ap 2,8 % negativ deviation Nominal data is the values we get from running E Cat with actual values from the measurement. Measurement made by: Stefan Orwén, Carrier AB, Malmö Un-biased validation of Performance – no Carrier inputs ClimaCheck on-line Fixed installation with web access Energy monitoring - statistics Early Warning 19 Hourly energy/cost statistics for owners • Energy statistics - cost • Monitor kWh and USD per hour • Documents “energy profile” versus ambient temperatures • Compare consumption with “energy profile” • Document energy optimisation projects • Benchmark different plant 20 Energy Statistics as optimisation tool Red line average daily temp Visualisation of optimisation June 14th Green line is 12 month average kWh at daily ambient 22 CONFRONTO SETTIMANALE CONSUMO IMPIANTO Italian Supermarket in Milano saving corresponds to 16 000 Euro per year Adj. controls Drift som tidigare 24 27% higher COP 24 Compressor Pack in Supermarket Comp 2 Low Efficiency 25 Compressor Pack in Supermarket Comp 2 Low Efficiency Full load Full load Full load Comp. Eff. 1, 3 and 4 Average Comp. Efficiency Comp 2 Low Efficiency 26 Stab. Stab. Stab. Savings achived in 6 Italian Supermarkets 27 PC-Software Documentation of performance and component by component evaluation Complete documentation 20 minutes to connect 28 Presentation of data is key for analyses 29 Comp. eff Start-up Part load Full load Part load Start-up Full load 100% Temp. diff. 9.3 K Secondary out – evaporation Good ≈ 3-5 K 67% Temp. diff. 9.3 K secondary out – condensing Good ≈ 1-4 K COP +10% at full load Compressor eff. 48% to 64% When part to full load Super heat. 0.8 K at part load -critical 32 8 compressors no need for part load > saving more than 5000 Euro 33 CO2 cascade system with R134a 34 Method has few limitation (complex systems can be made understandable) Industrial ammonia plant screws + oil cooling 35 35 Validated and well proven • Experience since 1986 when it was patented • Validated 1989 by SP - Swedish National Testing and Research Institute • 400 field measurement systems in use • Method used in education – Royal Institute of Technology in Stockholm (University level) – Swedish, German, Slovak, UK “trade training institute” • Used by 40 manufacturers of heat pumps, dehumidifiers, refrigeration and air conditioning equipment – Development laboratories – Product control in production – Commissioning, trouble shouting, warranty inspections and aftermarket • Integration in – OEM control systems – Building Management system (BMS) 36 ClimaCheck is achieving international acceptance • More than 40 manufacturers in 10 countries – World leading Compressor factories – Swedish, German, UK, Italian, Slovak, Czech, Thai, Korean, Finnish and Australian manufacturers use ClimaCheck in product development, prototype testing and trouble shooting • Leading installer – maintenance contractors (400+) • Leading supermarket chains in Sweden require documented commissioning with “ClimaCheck method” at commissioning of supermarkets and cold stores • TESCO, Sainsbury, Metro, Carrefour and El Gigante is now investing and setting requirements for contractors to document operation – You can test http://www.online.climacheck.com/ • user > climacheck , password > demo 001 37 Global Industry need tools and training to optimise Dynamics in real systems not well taken care off or understood 38