dopplers - ArjoHuntleigh
Transcription
dopplers - ArjoHuntleigh
HM005 Dopplers-ECG_HH1056 MasterQX 11/12/2010 17:36 Page 70 70 DOPPLERS FREEPHONE 0800 0855617 FREEFAX 0800 0859849 Automatic Ankle Brachial Index System Integral easy grip handle Integrated thermal printer (can be used with paper or label rolls) Clear display showing test status, numerical results, waveform and interpretation Simple user interface Colour coded, easy connect tubing Revolutionising Ankle Brachial Pressure Index Measurement Now with the Dopplex Ability Automatic ABI system, Ankle Brachial Index has never been simpler or quicker. Its portability enables measurements to be made more efficiently in the primary care clinic, hospital or patients home. This can lead to the prioritisation of clinical services by improving clinical pathways. ABIs are calculated easily and accurately in 3 minutes without the need to rest the patient. Results are automatically calculated, interpreted and displayed with Pulse Volume waveforms on the LCD panel. The test results can be printed on either thermal paper or adhesive backed label paper via the integral printer. • Portable and powered by mains or rechargeable battery – For home or clinical environments • Integral printer for documentation of results and waveforms – Instant hard copy for patient notes and reimbursement • Automatic interpretation of ABI – Reduces operator error • Accurate reproducible results – Clinically proven by recent studies HDOP040 dopplex ABIlity £1,850.00 HACC013 Trolley (requires fixing plate) £260.00 HACC054 Wall Mount (requires fixing plate) £337.00 • Extremely easy to use and fully automatic – Minimal training required HACC087 Wall Mount Tube Hooks (for HACC054 Wall Mount) £27.00 • No need to rest patient for 15 mins – Reduces total test time HACC012 Fixing Plate (for Trolley and Wall Mount) £15.00 HACC015 Carry Bag £50.00 HACC014 Standard Cuffs (4 x 29 – 42cm Arm and Ankle Cuffs) £265.00 HACC011 Large Cuffs (4 x 38 – 50cm Arm and Ankle Cuffs) £330.00 HACC016 Disposable Infection Control Sleeves (box of 100) £15.00 • Rapid bi-lateral ABI measurement in 3 mins. Doppler based ABI typically takes 30 mins – Simultaneous measurements reduces time • ABI can now be undertaken by healthcare support staff – Makes the measurement more cost effective • No need to remove patient’s socks or tights – Maintains patient comfort and dignity • Easy to apply 4 cuff system – Improves patient experience HM005 Dopplers-ECG_HH1056 MasterQX 11/12/2010 17:36 Page 71 DOPPLERS www.arjohuntleigh-medicaldirectory.co.uk [email protected] 71 dopplex® MD200 The MD200 is an innovative desktop solution for clinicians requiring a robust, versatile and rechargeable Doppler unit. Using up to eight interchangeable probes, it provides bi-directional measurement of vascular blood flow and high quality reports when linked to the Dopplex Reporter software. • Mains/battery operation • Robust design • Probes are conveniently stored within the unit • Enhanced battery power management • Advanced bi-directional unit with printout capability • LCD showing bi-directional flow, probe frequency and battery status • Serial port for connection to the Dopplex® Printa or Dopplex® Reporter software package • Two speakers providing flow separated high quality stereo sound • Ideal for measurement of ABPI and venous assessment in a clinic environment • Now available with a locking pole stand NOTE: Probe not included – see chart below. HDOP000 Doppler Probes Dopplex MD200 £639.00 Description Freq. Use Code Price OP2HS 2MHz Obstetric for fetal heart detection. HDOP061 £211.00 OP3HS 3MHz Obstetric for fetal heart detection in early gestation. HDOP062 £211.00 VP4HS 4MHz Detection of deep lying vessels. HDOP063 £211.00 VP5HS 5MHz For oedematous limbs and deep lying vessels. Ideal adjunct to Easy8 for ABPI measurements. HDOP064 £211.00 VP8HS 8MHz Detection of peripheral vessels and calcified arteries. HDOP065 £211.00 VP10HS 10MHz Detection of smaller vessels in specialist superficial applications. HDOP066 £211.00 EZ8 Wide Beam 8MHz Allows easy location of vessels. Easier to maintain vessel contact during inflation and deflation. HDOP067 £250.00 40mm * * 35mm 20mm * 15mm * 15mm * Approximate distances of peak sensitivity * HM005 Dopplers-ECG_HH1056 MasterQX 11/12/2010 17:36 Page 72 72 DOPPLERS FREEPHONE 0800 0855617 FREEFAX 0800 0859849 NOTE: Probe not included – see chart (page 71) Clear LCD screen On/Off button with enhanced battery management Integral probe connector dopplex® D900 Integrated probe parking and storage dopplex® SD2 dopplex® MD2 Non-directional Doppler Bi-directional Doppler Bi-directional Doppler The Dopplex® D900 is a low cost audio only, non-directional Doppler, principally used for ABPI measurements by community nurses and doctors in their role of leg ulcer management. The Dopplex® SD2 provides bi-directional vascular information to the vascular professional including the display of flow direction. It is ideal for clinical specialists wishing to conduct advanced Doppler studies. The Dopplex® MD2 is one of the most advanced pocket Dopplers on the market. It provides the ability for high level vascular assessment, and is ideal for the detection of peripheral arterial disease. When used with the high sensitivity vascular probes it provides quality bi-directional blood flow information. It can be linked to the Dopplex Reporter software package for high quality waveform reports or the Dopplex Printa for single waveform recordings. • Clear audio sounds of blood flow or fetal heart • Enhanced battery management • Compatible with all high sensitivity vascular probes (audio only with OP2 and OP3) • Compatible with the complete range of vascular probes • Ideal for ABPI assessment • When used with Easy 8 probe it is excellent for the infrequent user in • Provides bi-directional blood flow information locating brachial and pedal arteries • Large carry bag • Headphones included • Enhanced stereo audio output • Connects with all High Sensitivity probes (2, 3, 4, 5, 8, 10 MHz) • Provides bi-directional blood flow information and documentation • Large carry bag • Stereo headphones included • Integral battery management • Enhanced audio output • Large carry bag will hold sphyg and cuffs HDOP057 dopplex D900 £216.00 HDOP055 dopplex SD2 £340.00 HDOP054 dopplex MD2 £453.00 HM005 Dopplers-ECG_HH1056 MasterQX 11/12/2010 17:36 Page 73 www.arjohuntleigh-medicaldirectory.co.uk [email protected] dopplex® DFK Diabetic Foot Assessment Kit The Diabetic Foot Assessment Kit provides the professional vascular or diabetes specialist with a system to help in the assessment of neuropathy, ankle brachial pressure index (ABPI) and toe brachial pressure index (TBPI). Product includes: • Bi-directional Doppler (MD2) and probe (VP8HS) • Neuropen (includes 10g monofilament) • Trigger operated sphyg with a range of latex free cuffs (arm/ankle, large and small toe) • Free Educational DVD • Hard carry case • Set of guides (ABPI/TBPI) • Headphones • Box of Neuropen tips HDOP060 Diabetic Foot Assessment Kit £835.00 dopplex® ABPI Ankle Brachial Pressure Index Kit The ABPI Kit contains all the items required to undertake a full ABPI assessment on regular or oedematous limbs and includes two Doppler probes and cuffs. The Easy8 probe helps to locate vessels and also maintain vessel contact during inflation and deflation procedures, and the VP5 is ideal for oedematous limbs. Pack includes: • Dopplex® MD2 bi-directional Doppler • High sensitivity widebeam EZ8 8MHz probe • High sensitivity VP5HS 5MHz probe • Large arm/ankle cuff • Standard arm/ankle cuff • Sphygmomanometer (quick release) • ABPI Guide • Free Educational CD • Large carry bag HDOP096 Ankle Brachial Pressure Index Kit £927.00 dopplex® PAD Peripheral Arterial Disease Assessment Kit The PAD kit includes all the items required to undertake a basic assessment on patients at risk of arterial disease. Pack includes: • Dopplex D900 non-directional Doppler • High sensitivity widebeam EZ8 probe • Standard arm/ankle cuff • Sphygmomanometer • ABPI guide • Free Educational CD • Large carry bag HDOP070 Peripheral Arterial Disease Assessment Kit £494.00 DOPPLERS 73 HM005 Dopplers-ECG_HH1056 MasterQX 11/12/2010 17:36 Page 74 74 DOPPLERS FREEPHONE 0800 0855617 FREEFAX 0800 0859849 dopplex® DR3 Software Package Dopplex Reporter Package is a unique vascular reporting software package for use in conjunction with the dopplex RD2, MD2 and MD200 units. It enables complete vascular studies to be undertaken and saved in a patient database, and provides full page documented hard-copy printouts. It is easily installed and does not require any modification to your computer. Applications available in version 3.6 include: • Upper and lower limb arterial pressure and flow studies • Lower limb venous studies • Extracranial blood flow studies • Penile pressure and flow studies • Podiatry and chiropody studies • Pre/post operative studies • Surgical studies with flow calculations • PPG venous studies (Rheo only) • Doppler waveform parameter calculations • Compatible with Windows 98, 2000, XP, Vista and Windows 7 • USB and serial cables included HDOP023 dopplex Reporter Package £350.00 dopplex® Printa II Dopplex Printa II package is a portable, mains/battery thermal printer, which provides documentation of bi-directional Doppler waveforms when used with Dopplex MD2, RD2 and MD200. PPG curves can also be documented when used with the Dopplex RD2 unit. It is ideal for a clinic where portability is required. HDOP072 dopplex Printa II £489.00 HM005 Dopplers-ECG_HH1056 MasterQX 11/12/2010 17:37 Page 75 DOPPLERS www.arjohuntleigh-medicaldirectory.co.uk [email protected] 75 Interchangeable probe LCD display On/Off NOTE: Probe not included – see chart (page 71) sonicaid® D920 and D930 – Audio sonicaid® FD1 and FD3 – Rate sonicaid® FD2 – Rate Display Only Doppler with Waterproof Display Doppler with Waterproof Doppler with Interchangeable Probe Probe Probe Options This Audio Doppler has been designed with ease of use in mind. Its high sensitivity probe coupled with clear fetal heart sounds, enable the clinician to quickly locate the fetal heart. The FD1 is a highly versatile obstetric Doppler, with the added advantage of displaying the fetal heart rate. The high sensitivity 2MHz probe provides reliable detection throughout pregnancy. Our new D930 model meets the growing demand for a high sensitivity 3MHz Doppler for sensitive detection in early gestation. Our new FD3 model meets the growing demand for a high sensitivity 3MHz rate display Doppler for sensitive detection in early gestation. • High sensitivity ultrasound for improved ease of use. • Advanced real time auto-correlation fetal heart rate processing This top of the range handheld rate display Doppler features high sensitivity interchangeable probes. 2MHz for general obstetric use, 3MHz ideally suited for detecting the fetal heart in early gestations, and five other probes for vascular applications. An integrated data output allows a hard copy print out of the FHR trace to be obtained when connected to the Dopplex Printa. • Waterproof probe suitable for use in a water birthing environment • Active noise reduction for crystal clear fetal heart sounds • Battery low indicator • Waterproof probes suitable for use in a water birthing environment • Easy clean probe for improved infection control • Belt clip and neck-cord (option) to aid handling • Advanced power management with auto switch-off to conserve battery life • Long robust coiled cable enables optimum probe position in all circumstances • Large carry bag • Probe connector for interchangeable probe options • Unique fetal heart rate processing modes for optimum performance in the widest range of signal conditions • Real time fetal heart rate data output • Event marker for recording fetal movements when connected to the Dopplex Printa • 4, 5, 8, EZ8 and 10MHz vascular probe options • Large carry bag • Large carry bag HDOP059 sonicaid D920 £278.00 HDOP058 sonicaid FD1 £363.00 HDOP053 sonicaid D930 £278.00 HDOP052 sonicaid FD3 £363.00 HDOP056 sonicaid FD2 £259.00 HM005 Dopplers-ECG_HH1056 MasterQX 11/12/2010 17:37 Page 76 76 DOPPLERS FREEPHONE 0800 0855617 FREEFAX 0800 0859849 sonicaid® MD200 The MD200 is an innovative desktop solution for clinicians requiring a robust versatile and rechargeable Doppler unit. Using up to eight interchangeable probes, it enables accurate measurement of fetal heart rate. • Mains/battery operation • Robust design • Probes are conveniently stored within the unit • Superior audio (stereo when used with a vascular probe) • Enhanced battery power management • 3 year warranty (3 years on main unit, 1 year probe and cable) • High sensitivity 2 & 3MHz obstetric probe options for optimum performance from early gestation through to labour and delivery • Advanced auto-correlation fetal heart rate processing • LCD display of fetal heart rate, pulse and battery state • Real time data output for Non Stress Test (NST) screening • Easy detection of Fetal Heart sounds provide reassurance for clinician and mother to be NOTE: Probe not included – see chart (page 71) HDOP421 Sonicaid MD200 sonicaid® One £639.00 Comes complete with soft pouch, gel, batteries, user guide, pregnancy calculator and pen • Unique design – easy to use • Waterproof probe as standard • Fetal Heart Rate • Size Main unit: 128 x 68 x 38mm • Probe: 71mm x 32mm Ø • Weight: 230g (including probe and batteries) • Water protection probe and cable only • Power Supply: Battery 2 x AA 1.5V Alkaline or 2 x AA 1.2V NiCad • Battery life 1000 one minute examinations (Alkaline) • Auto Shut off 5 minutes in use / 2 minutes no signal • Ultrasound Frequency 2MHz Continuous Wave • Comes complete with soft pouch, gel, batteries, user guide, pregnancy calculator and pen Waterproof probe as standard HDOPSON1 Sonicaid One £348.00
Similar documents
Obstetric Doppler Brochure
• Battery low indicator • Easy clean transducer for improved infection control • Belt clip and neck-cord (option) to aid handling
More information