LaMETTRY'S COLLISION
AUDUBON ROAD
CHANHASSEN, MN
BEFORE YOU BEGIN - REQUIRED MATERIALS AND EQUIPMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
DRAWING INDEX
PROPER GEOTECHNICAL SOIL EVALUATION BY A QUALIFIED ENGINEER OR SOIL SCIENTIST TO
DETERMINE SUITABILITY OF STRUCTURAL INSTALLATION
OSHA COMPLIANCE
CULTEC WARNING TAPE, OR EQUIVALENT
ASSURANCES FROM LOCAL UTILITIES THAT NO UNDERGROUND GAS, ELECTRICAL OR OTHER
POTENTIALLY DANGEROUS PIPELINES OR CONDUITS ARE ALREADY BURIED AT THE SITE
ACCEPTABLE 1- 2 INCH (25 - 51 MM) WASHED, CRUSHED STONE AS DETAILED IN CULTEC'S
INSTALLATION INSTRUCTIONS. CLEANLINESS OF STONE TO BE VERIFIED BY ENGINEER.
ACCEPTABLE FILL MATERIAL AS SHOWN IN CULTEC'S INSTALLATION INSTRUCTIONS.
CULTEC NO. 410™ FILTER FABRIC OR EQUIVALENT NON-WOVEN FILTER FABRIC
ALL CULTEC CHAMBERS AND ACCESSORIES AS SPECIFIED IN THE ENGINEER'S PLANS INCLUDING
CULTEC NO. 410™ FILTER FABRIC, CULTEC STORMFILTER® AND CULTEC NO. 20L™ POLYETHYLENE
LINER, WHERE APPLICABLE.
CHECK CULTEC CHAMBERS FOR DAMAGE PRIOR TO INSTALLATION. DO NOT USE DAMAGED CULTEC
CHAMBERS, CONTACT YOUR SUPPLIER IMMEDIATELY TO REPORT DAMAGE OR PACKING-LIST
DISCREPANCIES.
RECIPROCATING SAW OR ROUTER
STONE BUCKET
STONE CONVEYOR AND/OR TRACKED EXCAVATOR
TRANSIT OR LASER LEVEL MEASURING DEVICE
COMPACTION EQUIPMENT WITH MAXIMUM GROSS VEHICLE WEIGHT OF 12,000 LBS (5,440 KGS).
VIBRATORY ROLLERS MAY ONLY BE USED ON THE STONE BASE PRIOR TO THE INSTALLATION OF
CHAMBERS.
REQUIREMENTS FOR CULTEC CHAMBER SYSTEM INSTALLATIONS
TITLE
SHEET NO.
NORTH SYSTEM LAYOUT SHEET
1 OF 6
MIDDLE SYSTEM LAYOUT SHEET
2 OF 6
2.
SOUTH SYSTEM LAYOUT SHEET
3 OF 6
SYSTEM CALCULATIONS SHEET
4 OF 6
3.
4.
150XLHD DETAIL SHEET
5 OF 6
SEPARATOR ROW DETAIL SHEET
6 OF 6
1.
5.
6.
7.
8.
PROJECT INFORMATION
PROJECT NO:
CULTEC SALES REP:
9.
10.
15-7230
JOHN DITULLIO
(203)-775-4416 EXT. 105
475-289-7105
11.
[email protected]
CULTEC CAD TECH:
DAN GERA
12.
(203)-775-4416 EXT. 129
13.
[email protected]
COMMENTS:
TM
CULTEC, Inc.
Subsurface Stormwater Management Systems
CULTEC
P.O. Box 280
878 Federal Road
Brookfield, CT 06804
www.cultec.com
PH: (203) 775-4416
PH: (800) 4-CULTEC
FX: (203) 775-1462
[email protected]
14.
INSTALLING CONTRACTORS ARE EXPECTED TO COMPREHEND AND USE THE MOST CURRENT
INSTALLATION INSTRUCTIONS PRIOR TO BEGINNING A SYSTEM INSTALLATION. IF THERE IS ANY
QUESTION AS TO WHETHER YOU POSSESS THE MOST CURRENT INSTRUCTIONS, CONTACT CULTEC
AT (203) 775-4416 OR VISIT WWW.CULTEC.COM.
CONTACT CULTEC AT LEAST THIRTY DAYS PRIOR TO SYSTEM INSTALLATION TO ARRANGE FOR A
PRE-CONSTRUCTION MEETING.
ALL CULTEC SYSTEM DESIGNS MUST BE CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER.
USE CULTEC INSTALLATION INSTRUCTIONS AS A GUIDELINE ONLY FOR MINIMUM/MAXIMUM
REQUIREMENTS. ACTUAL DESIGN MAY VARY. REFER TO APPROVED CONSTRUCTION DRAWINGS FOR
JOB-SPECIFIC DETAILS. BE SURE TO FOLLOW THE ENGINEER'S DRAWINGS AS YOUR PRIMARY
GUIDE.
THE FOUNDATION STONE SHALL BE LEVEL AND COMPACTED PRIOR TO CHAMBER INSTALLATION.
OVERLAPPING RIB CONNECTIONS OF CHAMBERS SHALL BE FULLY SHOULDERED PRIOR TO STONE
PLACEMENT.
CENTER TO CENTER SPACING SHALL BE CHECKED AND MAINTAINED THROUGHOUT INSTALLATION
PROCESS.
ANY DISCREPANCIES WITH THE SYSTEM SUB-GRADE SOIL'S BEARING CAPACITY MUST BE
REPORTED TO THE DESIGN ENGINEER.
FILTER FABRIC MUST BE USED AS SPECIFIED IN THE ENGINEER'S DRAWINGS.
CULTEC REQUIRES THE CONTRACTOR TO REFER TO CULTEC'S INSTALLATION INSTRUCTIONS
CONCERNING VEHICULAR TRAFFIC. RESPONSIBILITY FOR PREVENTING VEHICLES THAT EXCEED
CULTEC'S REQUIREMENTS FROM TRAVELING ACROSS OR PARKING OVER THE CHAMBER SYSTEM
LIES SOLELY WITH THE CONTRACTOR THROUGHOUT THE ENTIRE SITE CONSTRUCTION PROCESS.
THE PLACEMENT OF WARNING TAPE, TEMPORARY FENCING, AND/OR APPROPRIATELY LOCATED
SIGNS IS HIGHLY RECOMMENDED. IMPRINTED WARNING TAPE IS AVAILABLE FROM CULTEC. FOR
ACCEPTABLE VEHICLE LOAD INFORMATION, REFER TO CULTEC INSTALLATION INSTRUCTIONS.
TRAFFIC OF INSTALLATION EQUIPMENT OR OTHER VEHICULAR TRAFFIC OVER TOP OF THE CULTEC
STORMWATER SYSTEM IS STRICTLY RESTRICTED AND PROHIBITED UNTIL SATISFACTORY COVER
AND COMPACTION IS ACHIEVED ACCORDING TO CULTEC'S MANUFACTURER INSTALLATION
INSTRUCTIONS.
EROSION AND SEDIMENT-CONTROL MEASURES MUST MEET LOCAL CODES AND THE DESIGN
ENGINEER'S SPECIFICATIONS THROUGHOUT THE ENTIRE SITE CONSTRUCTION PROCESS.
CULTEC SYSTEMS MUST BE DESIGNED AND INSTALLED IN ACCORDANCE WITH CULTEC'S MINIMUM
REQUIREMENTS. FAILURE TO DO SO WILL VOID THE LIMITED WARRANTY.
CONTACT CULTEC, INC. AT 203-775-4416 WITH ANY QUESTIONS OR FURTHER CLARIFICATION OF
REQUIREMENTS.
THIS DRAWING WAS PREPARED TO SUPPORT THE DESIGN ENGINEER FOR THE PROPOSED SYSTEM. IT IS THE
ULTIMATE RESPONSIBILITY OF THE DESIGN ENGINEER TO ASSURE THAT THE STORMWATER SYSTEM'S DESIGN IS IN
FULL COMPLIANCE WITH ALL APPLICABLE LAWS AND REGULATIONS. IT IS THE DESIGN ENGINEER'S RESPONSIBILITY
TO ENSURE THAT THE CULTEC PRODUCTS ARE DESIGNED IN ACCORDANCE WITH CULTEC'S MINIMUM REQUIREMENTS.
CULTEC INC. DOES NOT APPROVE PLANS, SIZING, OR SYSTEM DESIGNS. THE DESIGNING ENGINEER IS RESPONSIBLE
FOR ALL DESIGN DECISIONS.
95.00' [28.96 m]
6.00' [1.83 m] WIDE POLYLINER
BENEATH FEED CONNECTORS
3.25' [0.99 m] CENTER-TO-CENTER
(6" SPACING BETWEEN ROWS)
CULTEC No. 20L POLYETHYLENE LINER TO BE PLACED
UNDER ALL CHAMBERS UTILIZING INTERNAL MANIFOLD
FEATURE AND UNDER ALL INLET/OUTLET PIPES
HVLV FC-24 FEED CONNECTOR
INV. = 946.50
47.00' [14.33 m]
INV. = 946.00
PROPOSED 10" PVC
HIGH-FLOW BYPASS
PROPOSED 12" PVC STM
(PER DRAINAGE PLAN)
CBMH A6
(PER DRAINAGE PLAN)
CBMH D1
(PER DRAINAGE PLAN)
PROPOSED 12" PVC STM
(PER DRAINAGE PLAN)
INSPECTION PORT
(SEE DETAIL)
10.00' [3.05 m] WIDE POLYLINER
BENEATH INLET/OUTLET PIPES
SEPARATOR ROW
(SEE DETAIL)
INV. = 946.00
CULTEC STORMWATER MANAGEMENT SYSTEM
TOTAL STORAGE PROVIDED: 6,616 c.f.
NORTH SYSTEM LAYOUT DETAIL
*SYSTEM INSTALLED REQUIRING TYPICAL STONE AMOUNTS OF
6 INCHES BELOW AND ABOVE CHAMBERS AND A
1 FT. [12 INCH] BORDER SURROUNDING
4 OZ. NON-WOVEN FILTER FABRIC AROUND
STONE. TOP AND SIDES ARE MANDATORY;
BOTTOM PER ENGINEER'S DESIGN PREFERENCE
NOTE: ALL EXTERNAL SYSTEM STRUCTURES, INLET/OUTLET PIPES,
AND PROPOSED ELEVATIONS MUST BE DESIGNED AND APPROVED BY
ENGINEER. ALL SYSTEM ELEVATIONS PROVIDED MUST BE VERIFIED BY
THE DESIGN ENGINEER AND THE DESIGN ENGINEER MUST ENSURE
CHAMBER BURIAL REQUIREMENTS ARE MET.
1 - 2 INCH [25- 51 mm] DIA.
WASHED, CRUSHED STONE
RECHARGER 150XLHD HEAVY DUTY CHAMBER
IN SEPARATOR ROW CONFIGURATION
PAVEMENT OR FINISHED GRADE
MIN. 95% COMPACTED FILL
LEGEND
NOTE: PROPOSED ELEVATIONS ONLY.
DESIGN ENGINEER MUST APPROVE
ALL SYSTEM ELEVATIONS
12.0' [3.65m] MAX.
BURIAL DEPTH
CULTEC HVLV FC-24
FEED CONNECTOR WHERE SPECIFIED
8.0" [204 mm] MIN.FOR PAVED
10.0" [254 mm] MIN.FOR UNPAVED
MATERIALS LIST
RECHARGER 150XLSHD STARTER
14
PIECES
RECHARGER 150XLSHD STARTER
TOP OF STONE ELEVATION = 948.04
6.0" [152 mm] MIN.
TOP OF CHAMBER ELEVATION = 947.54
RECHARGER 150XLIHD INTERMEDIATE
98
PIECES
RECHARGER 150XLEHD END
14
PIECES
HVLV FC-24 FEED CONNECTORS
28
PIECES
RECHARGER 150XLIHD INTERMEDIATE
RECHARGER 150XLEHD END
10" HIGH-FLOW BYPASS INV. = 946.50
12" STM INLET PIPE INV. = 946.00
12" STM OUTLET PIPE INV. = 946.00
18.5" [470 mm]
BOTTOM OF CHAMBER ELEVATION = 946.00
6.0" [152 mm] MIN.
BOTTOM OF STONE ELEVATION = 945.50
5
ROLLS
CULTEC NO. 20L POLYETHYLENE LINER
100
LINEAL FEET
1 1/2 - 2 INCH DIAMETER BROKEN STONE
409
TONS
CULTEC NO. 410 FILTER FABRIC 7.5' x 300'
HVLV FC-24 FEED CONNECTORS
CULTEC NO. 20L POLYETHYLENE LINER
12.0" [305 mm] MIN.
STONE BORDER
SEPARATOR ROWS MATERIALS
CULTEC NO. 410 FILTER FABRIC 7.5' x 300'
.3
ROLLS
TM
.3
Subsurface Stormwater Management Systems
CULTEC
DESIGN ENGINEER RESPONSIBLE FOR
ENSURING THE REQUIRED BEARING
CAPACITY OF SUB-GRADE SOILS (TYP.)
NORTH SYSTEM CROSS-SECTION DETAIL
ROLLS
CULTEC, Inc.
P.O. Box 280
878 Federal Road
Brookfield, CT 06804
www.cultec.com
39.0" [991 mm]
NON-WOVEN GEOTEXTILE
WOVEN GEOTEXTILE
CLASS 1 WOVEN GEOTEXTILE 7.5' x 300'
33.0" [838 mm]
CULTEC NO. 20L POLYETHYLENE LINER TO BE
PLACED BENEATH HVLV FC-24 FEED CONNECTORS
WHEN UTILIZING INTERNAL MANIFOLD AND ALL INLET
PIPES
PH: (203) 775-4416
PH: (800) 4-CULTEC
FX: (203) 775-1462
[email protected]
THIS DRAWING WAS PREPARED TO SUPPORT THE DESIGN ENGINEER FOR THE PROPOSED SYSTEM. IT IS THE
ULTIMATE RESPONSIBILITY OF THE DESIGN ENGINEER TO ASSURE THAT THE STORMWATER SYSTEM'S DESIGN IS IN
FULL COMPLIANCE WITH ALL APPLICABLE LAWS AND REGULATIONS. IT IS THE DESIGN ENGINEER'S RESPONSIBILITY
TO ENSURE THAT THE CULTEC PRODUCTS ARE DESIGNED IN ACCORDANCE WITH CULTEC'S MINIMUM REQUIREMENTS.
CULTEC INC. DOES NOT APPROVE PLANS, SIZING, OR SYSTEM DESIGNS. THE DESIGNING ENGINEER IS RESPONSIBLE
FOR ALL DESIGN DECISIONS.
LaMETTRY'S COLLISION
AUDUBON ROAD
CHANHASSEN, MN
NORTH SYSTEM SHEET
CULTEC RECHARGER® 150XLHD
PROJECT NO:
15-7230.00
DATE:
6/18/15
DESIGNED BY: DPG
DRAWN BY:
DPG
SCALE:
SHEET NO:
1 OF 6
N.T.S.
STMH A4
(PER DRAINAGE PLAN)
INV.= 946.50
PROPOSED 12" PVC STM
(PER DRAINAGE PLAN)
PROPOSED 10" PVC
HIGH-FLOW BYPASS
SEPARATOR ROW
(SEE DETAIL)
INV.= 946.50
CBMH C1
(PER DRAINAGE PLAN)
PROPOSED 12" PVC STM
(PER DRAINAGE PLAN)
INSPECTION PORT
(SEE DETAIL)
INV.= 946.00
56.75' [17.30 m]
1.00' [0.30 m]
STONE BORDER
CULTEC STORMWATER MANAGEMENT SYSTEM
TOTAL STORAGE REQUIRED: 5,366 c.f.
TOTAL STORAGE PROVIDED: 6,262 c.f.
CULTEC No. 20L POLYETHYLENE LINER TO BE PLACED
UNDER ALL CHAMBERS UTILIZING INTERNAL MANIFOLD
FEATURE AND UNDER ALL INLET/OUTLET PIPES
6.00' [1.83 m] WIDE POLYLINER
BENEATH FEED CONNECTORS
3.25' [0.99 m] CENTER-TO-CENTER
(6" SPACING BETWEEN ROWS)
(STORAGE PROVIDED IN CHAMBERS: 3,273 c.f.)
(STORAGE PROVIDED IN STONE: 2,989 c.f.)
*SYSTEM INSTALLED REQUIRING TYPICAL STONE AMOUNTS OF
6 INCHES BELOW AND ABOVE CHAMBERS AND A
1 FT. [12 INCH] BORDER SURROUNDING
74.50' [22.71 m]
NOTE:*ALL EXTERNAL SYSTEM STRUCTURES, INLET/OUTLET
PIPES, AND PROPOSED ELEVATIONS MUST BE DESIGNED AND
APPROVED BY ENGINEER. ALL SYSTEM ELEVATIONS PROVIDED MUST
BE VERIFIED BY THE DESIGN ENGINEER AND THE DESIGN ENGINEER
MUST ENSURE CHAMBER BURIAL REQUIREMENTS ARE MET.
4 OZ. NON-WOVEN FILTER FABRIC AROUND
STONE. TOP AND SIDES ARE MANDATORY;
BOTTOM PER ENGINEER'S DESIGN PREFERENCE
NORTH SYSTEM LAYOUT DETAIL
LEGEND
MATERIALS LIST
1 - 2 INCH [25- 51 mm] DIA.
WASHED, CRUSHED STONE
RECHARGER 150XLHD HEAVY DUTY CHAMBER
IN SEPARATOR ROW CONFIGURATION
PAVEMENT OR FINISHED GRADE
MIN. 95% COMPACTED FILL
RECHARGER 150XLSHD STARTER
17
PIECES
RECHARGER 150XLIHD INTERMEDIATE
85
PIECES
RECHARGER 150XLSHD STARTER
NOTE: PROPOSED ELEVATIONS ONLY.
DESIGN ENGINEER MUST APPROVE
ALL SYSTEM ELEVATIONS
12.0' [3.65m] MAX.
BURIAL DEPTH
CULTEC HVLV FC-24
FEED CONNECTOR WHERE SPECIFIED
8.0" [204 mm] MIN.FOR PAVED
10.0" [254 mm] MIN.FOR UNPAVED
RECHARGER 150XLIHD INTERMEDIATE
TOP OF STONE ELEVATION = 948.04
RECHARGER 150XLEHD END
17
PIECES
HVLV FC-24 FEED CONNECTORS
15
PIECES
5
ROLLS
CULTEC NO. 410 FILTER FABRIC 7.5' x 300'
CULTEC NO. 20L POLYETHYLENE LINER
65
LINEAL FEET
1 1/2 - 2 INCH DIAMETER BROKEN STONE
387
TONS
RECHARGER 150XLEHD END
HVLV FC-24 FEED CONNECTORS
ROLLS
18.5" [470 mm]
6.0" [152 mm] MIN.
CULTEC NO. 20L POLYETHYLENE LINER
SEPARATOR ROWS MATERIALS
.3
12" STM OUTLET PIPE INV. = 946.00
10" STM HIGH-FLOW INV. = 946.50
12" STM INLET PIPE INV. = 946.00
BOTTOM OF CHAMBER ELEVATION = 946.00
BOTTOM OF STONE ELEVATION = 945.50
STONE BORDER
CULTEC NO. 410 FILTER FABRIC 7.5' x 300'
6.0" [152 mm] MIN.
TOP OF CHAMBER ELEVATION = 947.54
12.0" [305 mm] MIN.
33.0" [838 mm]
DESIGN ENGINEER RESPONSIBLE FOR
ENSURING THE REQUIRED BEARING
CAPACITY OF SUB-GRADE SOILS (TYP.)
NON-WOVEN GEOTEXTILE
WOVEN GEOTEXTILE
CLASS 1 WOVEN GEOTEXTILE 7.5' x 300'
TM
.3
Subsurface Stormwater Management Systems
CULTEC
P.O. Box 280
878 Federal Road
Brookfield, CT 06804
www.cultec.com
MIDDLE SYSTEM CROSS-SECTION DETAIL
ROLLS
CULTEC, Inc.
PH: (203) 775-4416
PH: (800) 4-CULTEC
FX: (203) 775-1462
[email protected]
THIS DRAWING WAS PREPARED TO SUPPORT THE DESIGN ENGINEER FOR THE PROPOSED SYSTEM. IT IS THE
ULTIMATE RESPONSIBILITY OF THE DESIGN ENGINEER TO ASSURE THAT THE STORMWATER SYSTEM'S DESIGN IS IN
FULL COMPLIANCE WITH ALL APPLICABLE LAWS AND REGULATIONS. IT IS THE DESIGN ENGINEER'S RESPONSIBILITY
TO ENSURE THAT THE CULTEC PRODUCTS ARE DESIGNED IN ACCORDANCE WITH CULTEC'S MINIMUM REQUIREMENTS.
CULTEC INC. DOES NOT APPROVE PLANS, SIZING, OR SYSTEM DESIGNS. THE DESIGNING ENGINEER IS RESPONSIBLE
FOR ALL DESIGN DECISIONS.
39.0" [991 mm]
CULTEC NO. 20L POLYETHYLENE LINER TO BE
PLACED BENEATH HVLV FC-24 FEED CONNECTORS
WHEN UTILIZING INTERNAL MANIFOLD AND ALL INLET
PIPES
LaMETTRY'S COLLISION
AUDUBON ROAD
CHANHASSEN, MN
MIDDLE SYSTEM SHEET
CULTEC RECHARGER® 150XLHD
PROJECT NO:
15-7230.00
DATE:
6/18/15
DESIGNED BY: DPG
DRAWN BY:
DPG
SCALE:
SHEET NO:
2 OF 6
N.T.S.
76.25' [23.24 m]
INSPECTION PORT
(SEE DETAIL)
3.25' [0.99 m] CENTER-TO-CENTER
(6" SPACING BETWEEN ROWS)
SEPARATOR ROW
(SEE DETAIL)
INV. = 937.50
33.50' [10.21 m]
STMH A1
(PER DRAINAGE PLAN)
12" RCP
(PER DRAINAGE PLAN)
6.00' [1.83 m] WIDE POLYLINER
BENEATH FEED CONNECTORS
INV. = 938.00
INV. = 937.50
HVLV FC-24 FEED CONNECTOR
PROPOSED 10" PVC
HIGH-FLOW BYPASS
CULTEC No. 20L POLYETHYLENE LINER TO BE PLACED
UNDER ALL CHAMBERS UTILIZING INTERNAL MANIFOLD
FEATURE AND UNDER ALL INLET/OUTLET PIPES
PROPOSED 12" PVC STM
(PER DRAINAGE PLAN)
CBMH B1
(PER DRAINAGE PLAN)
CULTEC STORMWATER MANAGEMENT SYSTEM
TOTAL STORAGE PROVIDED: 6,616 c.f.
SOUTH SYSTEM LAYOUT DETAIL
*SYSTEM INSTALLED REQUIRING TYPICAL STONE AMOUNTS OF
6 INCHES BELOW AND ABOVE CHAMBERS AND A
1 FT. [12 INCH] BORDER SURROUNDING
NOTE: ALL EXTERNAL SYSTEM STRUCTURES, INLET/OUTLET PIPES,
AND PROPOSED ELEVATIONS MUST BE DESIGNED AND APPROVED BY
ENGINEER. ALL SYSTEM ELEVATIONS PROVIDED MUST BE VERIFIED BY
THE DESIGN ENGINEER AND THE DESIGN ENGINEER MUST ENSURE
CHAMBER BURIAL REQUIREMENTS ARE MET.
4 OZ. NON-WOVEN FILTER FABRIC AROUND
STONE. TOP AND SIDES ARE MANDATORY;
BOTTOM PER ENGINEER'S DESIGN PREFERENCE
1 - 2 INCH [25- 51 mm] DIA.
WASHED, CRUSHED STONE
RECHARGER 150XLHD HEAVY DUTY CHAMBER
IN SEPARATOR ROW CONFIGURATION
LEGEND
MATERIALS LIST
RECHARGER 150XLRHD STAND ALONE
RECHARGER 150XLSHD STARTER
22
PIECES
RECHARGER 150XLIHD INTERMEDIATE
22
PIECES
RECHARGER 150XLIHD INTERMEDIATE
2
PIECES
RECHARGER 150XLEHD END
22
PIECES
HVLV FC-24 FEED CONNECTORS
21
PIECES
3
ROLLS
CULTEC NO. 20L POLYETHYLENE LINER
100
LINEAL FEET
1 1/2 - 2 INCH DIAMETER BROKEN STONE
238
TONS
CULTEC NO. 410 FILTER FABRIC 7.5' x 300'
RECHARGER 150XLSHD STARTER
MIN. 95% COMPACTED FILL
NOTE: PROPOSED ELEVATIONS ONLY.
DESIGN ENGINEER MUST APPROVE
ALL SYSTEM ELEVATIONS
ROLLS
TM
.3
Subsurface Stormwater Management Systems
CULTEC
6.0" [152 mm] MIN.
10" HIGH-FLOW BYPASS INV. = 938.00
12" STM INLET PIPE INV. = 937.50
12" STM OUTLET PIPE INV. = 937.50
RECHARGER 150XLEHD END
18.5" [470 mm]
BOTTOM OF CHAMBER ELEVATION = 937.50
6.0" [152 mm] MIN.
BOTTOM OF STONE ELEVATION = 937.00
HVLV FC-24 FEED CONNECTORS
CULTEC NO. 20L POLYETHYLENE LINER
12.0" [305 mm] MIN.
NON-WOVEN GEOTEXTILE
33.0" [838 mm]
39.0" [991 mm]
CULTEC NO. 20L POLYETHYLENE LINER TO BE
PLACED BENEATH HVLV FC-24 FEED CONNECTORS
WHEN UTILIZING INTERNAL MANIFOLD AND ALL INLET
PIPES
DESIGN ENGINEER RESPONSIBLE FOR
ENSURING THE REQUIRED BEARING
CAPACITY OF SUB-GRADE SOILS (TYP.)
SOUTH SYSTEM CROSS-SECTION DETAIL
ROLLS
CULTEC, Inc.
P.O. Box 280
878 Federal Road
Brookfield, CT 06804
www.cultec.com
8.0" [204 mm] MIN.FOR PAVED
10.0" [254 mm] MIN.FOR UNPAVED
RECHARGER 150XLIHD INTERMEDIATE
WOVEN GEOTEXTILE
CLASS 1 WOVEN GEOTEXTILE 7.5' x 300'
CULTEC HVLV FC-24
FEED CONNECTOR WHERE SPECIFIED
TOP OF CHAMBER ELEVATION = 939.04
SEPARATOR ROWS MATERIALS
.3
12.0' [3.65m] MAX.
BURIAL DEPTH
TOP OF STONE ELEVATION = 939.54
STONE BORDER
CULTEC NO. 410 FILTER FABRIC 7.5' x 300'
PAVEMENT OR FINISHED GRADE
PH: (203) 775-4416
PH: (800) 4-CULTEC
FX: (203) 775-1462
[email protected]
THIS DRAWING WAS PREPARED TO SUPPORT THE DESIGN ENGINEER FOR THE PROPOSED SYSTEM. IT IS THE
ULTIMATE RESPONSIBILITY OF THE DESIGN ENGINEER TO ASSURE THAT THE STORMWATER SYSTEM'S DESIGN IS IN
FULL COMPLIANCE WITH ALL APPLICABLE LAWS AND REGULATIONS. IT IS THE DESIGN ENGINEER'S RESPONSIBILITY
TO ENSURE THAT THE CULTEC PRODUCTS ARE DESIGNED IN ACCORDANCE WITH CULTEC'S MINIMUM REQUIREMENTS.
CULTEC INC. DOES NOT APPROVE PLANS, SIZING, OR SYSTEM DESIGNS. THE DESIGNING ENGINEER IS RESPONSIBLE
FOR ALL DESIGN DECISIONS.
LaMETTRY'S COLLISION
AUDUBON ROAD
CHANHASSEN, MN
SOUTH SYSTEM SHEET
CULTEC RECHARGER® 150XLHD
PROJECT NO:
15-7230.00
DATE:
6/18/15
DESIGNED BY: DPG
DRAWN BY:
DPG
SCALE:
SHEET NO:
3 OF 6
N.T.S.
NORTH SYSTEM CALCULATIONS
TM
CULTEC, Inc.
Subsurface Stormwater Management Systems
CULTEC
P.O. Box 280
878 Federal Road
Brookfield, CT 06804
www.cultec.com
PH: (203) 775-4416
PH: (800) 4-CULTEC
FX: (203) 775-1462
[email protected]
MIDDLE SYSTEM CALCULATIONS
THIS DRAWING WAS PREPARED TO SUPPORT THE DESIGN ENGINEER FOR THE PROPOSED SYSTEM. IT IS THE
ULTIMATE RESPONSIBILITY OF THE DESIGN ENGINEER TO ASSURE THAT THE STORMWATER SYSTEM'S DESIGN IS IN
FULL COMPLIANCE WITH ALL APPLICABLE LAWS AND REGULATIONS. IT IS THE DESIGN ENGINEER'S RESPONSIBILITY
TO ENSURE THAT THE CULTEC PRODUCTS ARE DESIGNED IN ACCORDANCE WITH CULTEC'S MINIMUM REQUIREMENTS.
CULTEC INC. DOES NOT APPROVE PLANS, SIZING, OR SYSTEM DESIGNS. THE DESIGNING ENGINEER IS RESPONSIBLE
FOR ALL DESIGN DECISIONS.
LaMETTRY'S COLLISION
AUDUBON ROAD
CHANHASSEN, MN
CALCULATIONS SHEET
SOUTH SYSTEM CALCULATIONS
CULTEC RECHARGER® 150XLHD
PROJECT NO:
15-7230.00
DATE:
6/18/15
DESIGNED BY: DPG
DRAWN BY:
DPG
SCALE:
SHEET NO:
4 OF 6
N.T.S.
CULTEC RECHARGER
150XLHD SPECIFICATIONS
6.0" [150 mm] DIA.
INSPECTION PORT
CULTEC HVLV FC-24 FEED CONNECTOR PRODUCT SPECIFICATIONS
GENERAL
USED FOR RETENTION, RECHARGING, DETENTION OR CONTROLLING THE FLOW OF ON-SITE STORMWATER RUNOFF.
CHAMBER PARAMETERS
1. THE CHAMBERS WILL BE MANUFACTURED BY CULTEC, INC. OF BROOKFIELD, CT. (203-775-4416 OR 1-800-428-5832)
2. THE CHAMBER WILL BE VACUUM THERMOFORMED OF BLACK HIGH MOLECULAR WEIGHT HIGH DENSITY POLYETHYLENE (HMWHDPE.)
GENERAL
CULTEC HVLV FC-24 FEED CONNECTORS ARE DESIGNED TO CREATE AN INTERNAL MANIFOLD FOR CULTEC
RECHARGER 150XLHD STORMWATER CHAMBERS.
LARGE RIB
END DETAIL
MODEL 150XLRHD STAND ALONE
SMALL RIB
SMALL RIB
END DETAIL
LARGE RIB
CHAMBER PARAMETERS
1. THE CHAMBERS WILL BE MANUFACTURED BY CULTEC, INC. OF BROOKFIELD, CT. (203-775-4416 OR
1-800-428-5832)
33.0" [838 mm]
3. THE CHAMBER WILL BE ARCHED IN SHAPE.
4. THE CHAMBER WILL BE OPEN-BOTTOMED.
2. THE CHAMBER WILL BE VACUUM THERMOFORMED OF BLACK HIGH MOLECULAR WEIGHT HIGH DENSITY
POLYETHYLENE (HMWHDPE).
5. THE CHAMBER WILL BE JOINED USING AN INTERLOCKING OVERLAPPING RIB METHOD. CONNECTIONS MUST BE FULLY SHOULDERED
OVERLAPPING RIBS, HAVING NO SEPARATE COUPLINGS OR SEPARATE END WALLS.
3. THE CHAMBER WILL BE ARCHED IN SHAPE.
6. THE NOMINAL CHAMBER DIMENSIONS OF THE CULTEC RECHARGER 150XLHD SHALL BE 18.5 INCHES (470 mm) TALL, 33 INCHES (838 mm)
WIDE AND 11 FEET (3.35 m) LONG. THE INSTALLED LENGTH OF A JOINED RECHARGER 150XLHD SHALL BE 10.25 FEET (3.12 m).
SMALL RIB
4. THE CHAMBER WILL BE OPEN-BOTTOMED.
7. MAXIMUM INLET OPENING ON THE CHAMBER ENDWALL IS 12 INCHES (300 mm).
5. THE NOMINAL CHAMBER DIMENSIONS OF THE CULTEC HVLV FC-24 FEED CONNECTOR SHALL BE 12 INCHES
(305 MM) TALL, 16 INCHES (406 mm) WIDE AND 24.2 INCHES (614 mm) LONG.
8.
6.
MANIFOLD. THE NOMINAL INSIDE DIMENSIONS OF EACH SIDE PORTAL WILL BE 8.5 INCHES (216 mm) HIGH BY 12 INCHES (304 mm) WIDE.
MAXIMUM ALLOWABLE OUTER DIAMETER (O.D.) PIPE SIZE IN THE SIDE PORTAL IS 10.25 INCHES (260 mm).
132.0" [3353 mm]
LARGE RIB
MODEL RHD
MODEL 150XLRHD STAND ALONE
UNITS ARE USED AS SINGLE
STAND ALONE SECTIONS.
MODEL 150XLSHD STARTER
INSTALLED LENGTH = 123.0" [3125 mm]
62.5" [1589 mm]
59.5" [1510 mm]
WITHOUT STONE.
MODEL SHD
7. THE HVLV FC-24 FEED CONNECTOR CHAMBER SHALL HAVE 2 CORRUGATIONS.
9.
(406 mm) WIDE AND 24.2 INCHES (615 mm) LONG.
8. THE HVLV FC-24 FEED CONNECTOR MUST BE FORMED AS A WHOLE CHAMBER HAVING TWO OPEN END WALLS
AND HAVING NO SEPARATE END PLATES OR SEPARATE END WALLS. THE UNIT WILL FIT INTO THE SIDE
PORTALS OF THE CULTEC RECHARGER STORMWATER CHAMBER AND ACT AS CROSS FEED CONNECTIONS
CREATING AN INTERNAL MANIFOLD.
10.
11.
12. THE RECHARGER 150XLHD CHAMBER WILL HAVE THIRTY DISCHARGE HOLES BORED INTO THE SIDEWALLS OF THE UNIT'S CORE TO
PROMOTE LATERAL CONVEYANCE OF WATER.
MODEL 150XLSHD STARTER
UNITS ARE USED
TO BEGIN A LINE.
MODEL 150XLIHD INTERMEDIATE
SMALL RIB
LARGE RIB
9. THE CHAMBER WILL BE DESIGNED TO WITHSTAND TRAFFIC LOADS WHEN INSTALLED ACCORDING TO
CULTEC'S RECOMMENDED INSTALLATION INSTRUCTIONS.
SMALL RIB
LARGE RIB
10. THE CHAMBER SHALL BE MANUFACTURED IN AN ISO 9001:2008 CERTIFIED FACILITY.
MODEL IHD
13. THE RECHARGER 150XLHD CHAMBER SHALL HAVE 20 CORRUGATIONS.
14. THE ENDWALL OF THE CHAMBER, WHEN PRESENT, WILL BE AN INTEGRAL PART OF THE CONTINUOUSLY FORMED UNIT. SEPARATE END
PLATES CANNOT BE USED WITH THIS UNIT.
15. THE RECHARGER 150XLRHD STAND ALONE UNIT MUST BE FORMED AS A WHOLE CHAMBER HAVING TWO FULLY FORMED INTEGRAL
ENDWALLS AND HAVING NO SEPARATE END PLATES OR SEPARATE ENDWALLS.
16. THE RECHARGER 150XLSHD STARTER UNIT MUST BE FORMED AS A WHOLE CHAMBER HAVING ONE FULLY FORMED INTEGRAL ENDWALL
AND ONE PARTIALLY FORMED INTEGRAL ENDWALL WITH A LOWER TRANSFER OPENING OF 10 INCHES (254 mm) HIGH X 20.5 INCHES (521
mm) WIDE.
17. THE RECHARGER 150XLIHD INTERMEDIATE UNIT MUST BE FORMED AS A WHOLE CHAMBER HAVING ONE FULLY OPEN ENDWALL AND
ONE PARTIALLY FORMED INTEGRAL ENDWALL WITH A LOWER TRANSFER OPENING OF 10 INCHES (254 mm) HIGH X 20.5 INCHES (521 mm)
WIDE.
18. THE RECHARGER 150XLEHD END UNIT MUST BE FORMED AS A WHOLE CHAMBER HAVING ONE FULLY FORMED INTEGRAL ENDWALL AND
ONE FULLY OPEN END WALL AND HAVING NO SEPARATE END PLATES OR END WALLS.
19.
SEPARATE END PLATES OR SEPARATE END WALLS. THE UNIT WILL FIT INTO THE SIDE PORTALS OF THE RECHARGER 150XLHD AND ACT
AS CROSS FEED CONNECTIONS.
CULTEC NO. 20L™ POLYETHYLENE LINER
GENERAL
CULTEC NO. 20L POLYETHYLENE LINER IS DESIGNED AS AN IMPERVIOUS UNDERLAYMENT TO PREVENT
SCOURING OF THE STONE BASE CAUSED BY WATER MOVEMENT WITHIN THE CULTEC SYSTEM. CULTEC NO.
20L POLYETHYLENE LINER IS TO BE PLACED BENEATH HVLV FC-24 FEED CONNECTORS WHEN UTILIZING
INTERNAL MANIFOLD AND BENEATH ALL INLET PIPES.
SIDE PORTAL FOR OPTIONAL
INTERNAL MANIFOLD
(ACCOMMODATES CULTEC HVLV
FC-24 FEED CONNECTOR OR
10.25 INCH (260 mm) MAX. O.D PIPE)
MODEL 150XLEHD END
SMALL RIB
LARGE RIB
18.5" [470 mm]
10.0" [254 mm]
MODEL 150XLIHD INTERMEDIATE
UNITS ARE USED AS MIDDLE
SECTIONS TO EXTEND THE
LENGTH OF A LINE.
20.5" [521 mm]
LINER PARAMETERS
MODEL EHD
1. THE LINER WILL BE PROVIDED BY CULTEC, INC. OF BROOKFIELD, CT. (203-775-4416 OR 1-800-428-5832)
2. THE LINER WILL BE BLACK IN APPEARANCE.
3. THE LINER WILL HAVE A NOMINAL THICKNESS OF 20 mil (0.51 mm).
INSTALLED LENGTH ADJUSTMENT = 0.75' [0.23 m]
ALL RECHARGER 150XLHD HEAVY-DUTY UNITS ARE MARKED WITH A COLORED
STRIPE FORMED INTO THE PART ALONG THE LENGTH OF THE CHAMBER.
SIDE PORTAL ACCEPTS CULTEC HVLV FC-24 FEED CONNECTOR.
4.
5. THE LINER WILL HAVE A TENSILE STRENGTH @ BREAK 1" (2.54 cm) OF 75 LBS (334 n) PER ASTM D6693
TESTING METHOD.
MODEL 150XLEHD UNITS
ARE USED TO END THE
LENGTH OF A LINE.
6. THE LINER WILL HAVE AN ELONGATION AT BREAK OF 800% PER ASTM D6693 TESTING METHOD.
20. CHAMBERS MUST HAVE HORIZONTAL STIFFENING FLEX REDUCTION STEPS BETWEEN THE RIBS.
7. THE LINER WILL HAVE A TEAR RESISTANCE OF 11 LBF (49 N) PER ASTM D1004 TESTING METHOD.
21. HEAVY DUTY UNITS ARE DESIGNATED BY A COLORED STRIPE FORMED INTO THE PART ALONG THE LENGTH OF THE CHAMBER.
22. THE CHAMBER WILL HAVE A RAISED INTEGRAL CAP AT THE TOP OF THE ARCH IN THE CENTER OF EACH UNIT TO BE USED AS AN
OPTIONAL INSPECTION PORT OR CLEAN-OUT.
23. THE UNITS MAY BE TRIMMED TO CUSTOM LENGTHS BY CUTTING BACK TO ANY CORRUGATION.
9. THE LINER WILL HAVE A PUNCTURE RESISTANCE OF 30 LBF (133 N) PER ASTM D4833 TESTING METHOD.
11. THE LINER WILL HAVE A DIMENSIONAL STABILITY OF <2% PER ASTM D1204 TESTING METHOD.
25. THE CHAMBER WILL BE DESIGNED TO WITHSTAND TRAFFIC LOADS WHEN INSTALLED ACCORDING TO CULTEC'S RECOMMENDED
INSTALLATION INSTRUCTIONS.
26. MAXIMUM ALLOWED COVER OVER TOP OF UNIT SHALL BE 12 FEET (3.65 m).
CULTEC RECHARGER 150XLHD HEAVY DUTY END DETAIL INFORMATION
METHOD.
10. THE LINER WILL HAVE A VOLATILE LOSS OF <1% PER ASTM D1203 TESTING METHOD.
24. THE CHAMBER SHALL BE MANUFACTURED IN AN ISO 9001:2008 CERTIFIED FACILITY.
CULTEC RECHARGER 150XLHD HEAVY DUTY THREE VIEW
8. THE LINER WILL HAVE A HYDROSTATIC RESISTANCE OF 100 PSI (689 kpa) PER ASTM D751 TESTING
CULTEC HVLV FC-24
FEED CONNECTOR WHERE SPECIFIED
12.
RECHARGER 150XLHD
HEAVY DUTY CHAMBER
13.
14. THE LINER WILL HAVE A PERM RATING OF 0.041 U.S. PERMS (0.027 METRIC PERMS) PER ASTM E96
PAVEMENT OR FINISHED GRADE
METHOD A.
16. THE LINER WILL NOT CONTAIN PLASTICIZERS.
4 OZ. NON-WOVEN FILTER FABRIC AROUND
STONE. TOP AND SIDES ARE MANDATORY;
BOTTOM PER ENGINEER'S DESIGN PREFERENCE
HIDDEN END
MIN. 95% COMPACTED FILL
12.0' [3.65m] MAX.
BURIAL DEPTH
15. THE LINER WILL CONSIST OF A BLENDED LINEAR POLYETHYLENE.
MODEL 150XLEHD
1 - 2 INCH [25- 51 mm] DIA. WASHED,
CRUSHED STONE
8.0" [204 mm] MIN.FOR PAVED
10.0" [254 mm] MIN.FOR UNPAVED
GENERAL NOTES
MODEL 150XLIHD
6.0" [152 mm] MIN.
CULTEC HVLV FC-24
FEED CONNECTOR
18.5" [470 mm]
CULTEC RECHARGER
150XLHD CHAMBER
PIPE PER ENGINEER DESIGN
(MAX. O.D. = 10.25 INCHES [260 mm])
(SEE FIGURE 1)
MODEL 150XLIHD
6.0" [152 mm] MIN.
HIDDEN END
PIPE PER ENGINEER DESIGN
(MAX. INLET = 12 INCHES [300 mm])
12.0" [305 mm] MIN.
33.0" [838 mm]
CULTEC NO. 20L POLYETHYLENE LINER TO BE
PLACED BENEATH HVLV FC-24 FEED CONNECTORS
WHEN UTILIZING INTERNAL MANIFOLD AND ALL INLET
PIPES
39.0" [991 mm]
DESIGN ENGINEER RESPONSIBLE FOR
ENSURING THE REQUIRED BEARING
CAPACITY OF SUB-GRADE SOILS (TYP.)
CULTEC HVLV FC-24
FEED CONNECTOR
INLET
STRUCTURE
GENERAL NOTES
RECHARGER 150XLHD BY CULTEC, INC. OF BROOKFIELD, CT.
FIGURE 1
MAX. PIPE
O.D.= 10.25 INCHES
[260 mm]
CULTEC RECHARGER
150XLHD CHAMBER
INLET
STRUCTURE
REFER TO CULTEC, INC.'S CURRENT RECOMMENDED INSTALLATION
GUIDELINES.
MAXIMUM ALLOWED COVER OVER TOP OF UNIT SHALL BE 12 '(3.65m).
THE CHAMBER WILL BE DESIGNED TO WITHSTAND TRAFFIC LOADS
WHEN INSTALLED ACCORDING TO CULTEC'S RECOMMENDED
INSTALLATION INSTRUCTIONS.
CULTEC HVLV FC-24
FEED CONNECTOR
MODEL 150XLSHD
ALL RECHARGER 150XLHD HEAVY DUTY UNITS ARE MARKED WITH A
COLORED STRIPE FORMED INTO THE PART ALONG THE LENGTH OF THE
CHAMBER.
ALL RECHARGER 150XLHD CHAMBERS MUST BE INSTALLED IN
ACCORDANCE WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL
REGULATIONS.
TRIM PORTAL TO UTILIZE
INTERNAL MANIFOLD FEATURE
CULTEC HVLV FC-24
FEED CONNECTOR
ZOOM OF SIDE PORTAL SHOWING MAX. PIPE O.D.
CULTEC TYPICAL INLET CONNECTION
CULTEC RECHARGER 150XLHD HEAVY DUTY TYPICAL CROSS SECTION
CULTEC RECHARGER 150XLHD HEAVY DUTY TYPICAL INTERLOCK
1-2" [25-51 mm] WASHED, CRUSHED
STONE SURROUNDING CHAMBERS
AND 8.0" [203 mm] MIN. INTO CHAMBER
PAVEMENT OR FINISHED GRADE
RECHARGER 150XL HEAVY DUTY CHAMBER
4 OZ. NON-WOVEN FILTER FABRIC AROUND STONE.
TOP AND SIDES ARE MANDATORY; BOTTOM PER
ENGINEER'S DESIGN PREFERENCE
24.2" [614 mm]
PAVEMENT SUB-BASE (WHEN APPLICABLE)
OPTIONAL INSPECTION PORT
(SEE DETAIL
)
27.2" [691 mm] MIN.
SQUARE
MINIMUM 95% COMPACTED FILL
4 OZ. NON-WOVEN FILTER FABRIC AROUND
STONE. TOP AND SIDES ARE MANDATORY;
BOTTOM PER ENGINEER'S DESIGN
PREFERENCE
MODEL FC 24
10.25"
[260 mm]
PAVEMENT OR FINISHED GRADE
6.0" [152 mm] MIN.
12.0" [300 mm]
MAX. INLET
12.0" [305 mm] MIN.
6.0 INCH [152 mm] MIN. DEPTH OF 1-2 INCH
[25-51 mm] WASHED CRUSHED
STONE BENEATH AND ABOVE CHAMBERS
16.0" [406 mm]
CULTEC FC
NEENAH FOUNDRY
MODEL R-5900-A
(OR EQUAL) HEAVY DUTY
FRAME AND LID
CULTEC, Inc.
Subsurface Stormwater Management Systems
CULTEC
P.O. Box 280
878 Federal Road
Brookfield, CT 06804
www.cultec.com
6.0" [152 mm] MIN.
MAINTAIN 6.0" [152 mm] CLEARANCE BETWEEN
HEAVY DUTY LID AND PVC CLEAN-OUT CAP
SIDE PORTAL TO BE CUT IN FIELD TO ALLOW FOR
HVLV FC-24 FEED CONNECTOR AS NEEDED. CUT
SHALL BE WITHIN 1/4" [6 mm] TOLERANCE OF
SIDE PORTAL TRIM GUIDELINE
6.0" [150 mm] SDR-35 / SCH. 40 PVC ENDCAP
CLEAN-OUT ADAPTER W/ SCREW-IN CAP
PH: (203) 775-4416
PH: (800) 4-CULTEC
FX: (203) 775-1462
[email protected]
12.0" [305 mm] MIN.
CULTEC NO. 20L POLYETHYLENE LINER TO BE
PLACED BENEATH HVLV FC-24 FEED CONNECTORS
WHEN UTILIZING INTERNAL MANIFOLD AND BENEATH
ALL INLET PIPES
6.0" [150 mm] SDR-35 / SCH. 40 PVC COUPLING
TRIM CHAMBER INSPECTION PORT KNOCK-OUT TO
MATCH O.D. OF 6.0" [150 mm] INSPECTION PORT PIPE
12.0 INCH [305 mm] MIN. WIDTH OF 1-2 INCH
[25-51 mm] WASHED CRUSHED STONE
BORDER SURROUNDING ALL CHAMBERS
TM
12.0" [300 mm] SDR-35 / SCH. 40 PVC COLLAR
6.0" [150 mm] SDR-35 / SCH. 40 PVC RISER
6.0' [1.8 m] MIN.
CULTEC NO. 20L POLYETHYLENE
LINER BENEATH FEED CONNECTORS
CULTEC RECHARGER 150XLHD HEAVY DUTY PLAN VIEW
18.5" [471 mm]
FIELD PLACED CLASS "C" CONCRETE
CULTEC RECHARGER 150XLHD
HEAVY-DUTY CHAMBER
PIPE DESIGN AND ELEVATION TBD BY ENGINEER.
PIPE TO BE INSERTED 8.0 INCHES [203 mm] MIN. INTO CHAMBER.
MAX. 12.0 INCHES [300 mm] PIPE ALLOWED IN ENDWALL
8.0" [202 mm] MIN.
FOR PAVED
10.0" [254 mm] MIN.
FOR UNPAVED
PAVEMENT OR
FINISHED GRADE
16.4" [418 mm]
CULTEC HVLV FC-24 FEED CONNECTOR
WHERE SPECIFIED
10.0' [3.0 m] MIN.
CULTEC NO. 20L POLYETHYLENE
LINER BENEATH INLET PIPES
MIN. 95% COMPACTED FILL
12.0' [3.65m] MAX.
BURIAL DEPTH
6.0" [150 mm] SDR-35 / SCH 40 PVC
(INSERTED 8.0" [203 mm] INTO CHAMBER)
12.0" [305 mm]
CULTEC HVLV FC-24
FEED CONNECTOR THREE VIEW
OPTIONAL INSPECTION PORT - ZOOM DETAIL
THIS DRAWING WAS PREPARED TO SUPPORT THE DESIGN ENGINEER FOR THE PROPOSED SYSTEM. IT IS THE
ULTIMATE RESPONSIBILITY OF THE DESIGN ENGINEER TO ASSURE THAT THE STORMWATER SYSTEM'S DESIGN IS IN
FULL COMPLIANCE WITH ALL APPLICABLE LAWS AND REGULATIONS. IT IS THE DESIGN ENGINEER'S RESPONSIBILITY
TO ENSURE THAT THE CULTEC PRODUCTS ARE DESIGNED IN ACCORDANCE WITH CULTEC'S MINIMUM REQUIREMENTS.
CULTEC INC. DOES NOT APPROVE PLANS, SIZING, OR SYSTEM DESIGNS. THE DESIGNING ENGINEER IS RESPONSIBLE
FOR ALL DESIGN DECISIONS.
CULTEC INTERNAL MANIFOLD - OPTIONAL INSPECTION PORT DETAIL
RECHARGER 150XLHD
DETAIL SHEET
TRAFFIC APPLICATION
CULTEC RECHARGER® 150XLHD
PROJECT NO:
DATE:
04/2014
DESIGNED BY: CULTEC, INC
DRAWN BY:
TECH
SCALE:
SHEET NO:
1 OF 2
N.T.S.