humidity/temperature measurement
Transcription
humidity/temperature measurement
HUMIDITY/TEMPERATURE MEASUREMENT 2006/2007 Unit 1A Crompton Fields Crompton Way Crawley, West Sussex RH10 9EE Telephone +44 1293 571000 Fax +44 1293 571008 www.rotronic.co.uk 56, bd Courcerin, Bat. 44 77183 Croissy Beaubourg, France Téléphone +33 1 60 95 07 10 Fax +33 1 60 17 12 56 www.rotronic.fr 160, East Main Street Huntington N.Y. 11743, USA Telephone +1 631 427 38 98 Fax +1 631 427 39 02 www.rotronic-usa.com 2B, Zao Fong Universe Building No. 1800 Zhong Shan West Road Shanghai 200233, China Telephone +86 21 644 03 55 Fax +86 21 644 03 77 www.rotronic.cn HUMIDITY / TEMPERATURE MEASUREMENT Einsteinstrasse 17- 23 D-76275 Ettlingen Telefon +49 7243 383 250 Fax +49 7243 383 260 www.rotronic.de 2005/ 2007 Grindelstrasse 6 CH-8303 Bassersdorf Telefon +41 44 838 11 44 Fax +41 44 837 00 73 www.rotronic.com How to contact ROTRONIC? ROTRONIC is a family owned group of companies with headquarters in Switzerland, and subsidiaries and distributors world-wide. Contact information can be found at www.rotronic-humidity.com. Rotronic Instruments Inc. is a subsidiary of Rotronic AG, with a team of sales, technical and support staff dedicated to humidity measurement products. Our territory includes all of North America as well as parts of Central America and South America. Te rm s a n d C o n d i t i o n s o f Tra d i n g WARRANTY If the Buyer fails to make advance payment when requested to do so by Rotronic, or if Subject to the exceptions and upon the conditions specified below Rotronic agrees to Buyer is or becomes delinquent in the payment of any sum due Rotronic, or refuses to correct, either by repair or at its election, by replacement any defects of material or work- accept C.O.D. shipments then Rotronic shall have the right, in addition to any other remedy manship which develop within one (1) year after date of shipment of the product to the to which it may be entitled in law or in equity, to cancel any Sales Order, refuse to make original Buyer by Rotronic, provided the investigation and inspection by Rotronic discloses further deliveries, and declare immediately due and payable all unpaid amounts for goods that the product had manufacturing defects. previously delivered to Buyer. Each shipment shall be considered a separate and independent transaction and payment therefore shall be made accordingly. Any product claimed to be defective must, if requested by Rotronic, be returned to the How to contact us: factory, transportation charges prepaid, and will be returned to Buyer with the transpor- SHIPMENTS tation charges collect. Products found by us to have any manufacturing defects will be Buyer is obligated to verify that any shipment corresponds to the packing slip. Shipments returned without charge to the Buyer, method of return to be determined by Rotronic. that show any shortages or discrepancy have to be reported in writing and returned in full to Rotronic within a period of ten (10) days from receipt of such shipment by the buyer Rotronic Instrument Corp. 160 E. Main Street Huntington, NY 11743 Rotronic shall be released from all obligations under all warranties either expressed or thereof. In the case a shortage or discrepancy claim is made, Rotronic’s sole liability is implied, if any product covered hereby is repaired or modified by persons other than its limited to correcting the shipment or refunding the Buyer if no correction can be made own authorized service personnel. unless such repair by others is made with the written within reasonable time. After expiration of the ten (10) day period, Rotronic will not be consent of Rotronic or unless such repair in the sole opinion of Rotronic is minor or unless responsible for any shortage or discrepancy and the shipment will be deemed to be con- such modification is merely the installation of a new Rotronic plug-in component for such forming to the packing slip. product CANCELLATION AND RESTOCKING CHARGES 800-628-7101 631-427-3902 Our Service to You ROTRONIC MAKES NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF Orders may not be cancelled and shipments returned without Rotronic’s written accep- THE PRODUCTS COVERED HEREBY OTHER THAN AS EXPRESSLY STATED HEREIN, tance and payment of a charge by the Buyer. Cancellation and restocking charges will be • Competitive prices ROTRONIC EXPRESSLY AND SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTY OF based on the cost, including engineering, drafting, materials, labor and sales work incur- MERCHANTABILITY AND MAKES NO WARRANTY WITH RESPECT TO THE FITNESS OF red by Rotronic. If cancellation or return is approved by Rotronic, the following will apply: • High quality products ANY PRODUCT COVERED HEREBY FOR ANY PARTICULAR PURPOSE OR USE UNLESS • ISO9001 production quality system • Comprehensive 12 month warranty [email protected] • Dedicated team, specializing in humidity SUCH A WARRANTY IS EXPRESSLY SET FORTH. 1) Minimum charge of 25% of sales price, prior to any discount, if order is not in manufacturing or if return concerns standard products in quantities of no more than ten (10) units. THE BUYER OR ANYONE CLAIMING UNDER ANY WARRANTY RELATING TO PRODUCTS 2) Minimum charge of 50% of sales price, prior to any discount, if order is in manufacturing SOLD HEREUNDER AGREES THAT IF ROTRONIC BREACHED ANY SUCH WARRANTY, or if return concerns non-standard products or standard products in quantities of more OR ANY WARRANTY IMPLlED EITHER IN FACT OR BY OPERATION OF LAW, OR IF ANY than ten (10) units. PRODUCTWARRANTED HEREUNDER PROVES DEFECTIVE IN ANY MANNERWHATSOEVER, ROTRONIC SOLE LIABILITY HEREUNDER IS LIMITED TO EITHER REPLACEMENT OF ANY DELIVERY DEFECTIVE PRODUCT OR AT THE, OPTION OF ROTRONIC, REFUNDING TO THE BUYER The scheduled shipping or delivery date is our best estimate of the time the order will be THE PURCHASE PRICE PAID FOR SUCH DEFECTIVE PRODUCT. THE BUYER AND ANYONE shipped and Rotronic assumes no liability for loss, general damages, or special or conse- ELSE CLAIMING UNDER ANY WARRANTY RELATING TO PRODUCTS SOLD HEREUNDER quential damages due to delays. EXPRESSLY AND SPECIFICALLY AGREE THAT ROTRONIC IS NOT RESPONSIBLE FOR, www.rotronic-usa.com AND THE BUYER OR SUCH OTHER CLAIMANT OR CLAIMANTS SHALL ASSUME, ANY TAXES AND DUTIES LIABILITY FOR PROPERTY DAMAGE, PROSPECTIVE PROFITS, SPECIAL, INDIRECT, OR Federal, state or local excise, sales or use taxes shall be paid by Buyer. Buyers claiming CONSEQUENTIAL DAMAGE, OR OTHER COMMERCIAL OR ECONOMIC LOSS ARISING OUT tax exemption are responsible for providing Rotronic with all legally required documents OF USE OR POSSESSION OF ANY PRODUCT SOLD HEREUNDER. ROTRONIC SHALL NOT and statements. Import duties and any other charges shall be paid by Buyers outside of BE LIABLE FOR, AND A BUYER OR ANYONE ELSE CLAIMING UNDER ANY WARRANTY the United States. RELATING TO PRODUCTS SOLD HEREUNDER FURTHER AGREES, AND SHALL ASSUME, ANY LIABILITY FOR PERSONAL INJURY ARISING OUT OF USE OR POSSESSION OF ANY PATENTS PRODUCT SOLD HEREUNDER. Rotronic agrees to defend any suit or proceeding brought against Buyer so far as based upon an assertion that any product, or any part thereof, sold under a Sales Order consti- Buying from ROTRONIC INSTRUMENTS Contact our experienced sales team for product and application advice, current pricing and availability. Our field sales team offer on-site application consultancy and product technical support throughout the United States. Core products can be purchased on-line at www.rotronic-usa.com Terms and conditions of trading see page 129. If a Rotronic Special Warranty covering a designated item or items is attached hereto the tutes a direct infringement of any United States patent having a claim or claims covering terms and conditions specified therein are incorporated herein by reference and shall solely the product itself, or any part thereof, or the normal use for which such product or supplement this warranty, in the event of a conflict between the terms and/or conditions part was designed, if notified promptly in writing and given authority, information and specified herein and those specified in such Special Warranty, the terms and/or conditions assistance (at Rotronic expense) for the defense of same, and Rotronic shall pay all da- of the Special Warranty shall control. mages and costs awarded therein against Buyer. If said product, or any part thereof, is in such suit held to constitute infringement and the use of said product or part is enjoined, Representations and warranties made by any person, including dealers and represen- Rotronic shall at its own option and at its own expense either (I) procure for Buyer the right tatives of Rotronic. which are inconsistent or in conflict with the terms of this warranty to continue using said product or part, (II) replace the same with a non-infringing product (including but not limited to the limitations of the liability of Rotronic as set forth above), or part, (III) modify it so it becomes non-infringing, or (IV) remove said product or part and shall not be binding upon Rotronic unless given in writing and approved by an expressly refund the purchase price and transportation costs thereof. The foregoing obligations of authorized representative of Rotronic. Rotronic shall not apply to any infringement claim based upon (I) any use of any product sold hereunder in any process (other than a process carried out by such product as an PRICES inherent function of such product or in conjunction with any other product (unless such The prices set forth are based upon the manufacture of the quantity and type ordered other product is an accessory especially designed and sold by Rotronic for use with the and are subject to revision when interruption, engineering changes or changes in quantity product sold hereby) or (II) any product manufactured to Buyer’s design or any product Warranty or quality are caused or requested by Buyer. Prices do not include warranty service or having a design arising out of compliance with Buyer’s specifications. The foregoing states installation outside the United States and Canada. Clerical errors made by Rotronic are the entire liability of Rotronic for patent infringement by said product. All ROTRONIC products now have a 1 year warranty. subject to correction. Service and Calibration Our technical support team offer a wide range of services including repairs, calibration and service contracts. Contact [email protected]. LIMITATION OF ACTIONS SPECIFICATIONS No action, shall be brought for any breach of this contract more than one (1) year after the Weights and dimensions set forth in sales literature are not guaranteed unless previously accrual of the cause of action therefore. certified in writing. Rotronic may, without affecting the obligations under a Sales Order, make insignificant changes in the specifications of the product or products delivered under ACCEPTANCE the Sales Order from those contained in sales literature. No acceptance of the terms and conditions of this sale shall be effective which varies the terms hereof or proposes additional terms. Any such proposals shall be deemed rejected TERMS OF PAYMENT unless expressly approved by Rotronic Terms of payment are net thirty (30) days from date of the invoice unless otherwise specifically stated. Invoices are payable at par on date due at any place of collection designated APPLICABLE LAW by Rotronic in funds bankable. All orders are accepted subject to and the obligation of This contract shall be governed and construed in accordance with the law of the State of Rotronic to make deliveries is subject to, the right of Rotronic to require of Buyer payment New York. The venue for any action arising out of this agreement shall be Suffolk County, of all or any part of the purchase price in advance of delivery or to make shipment C.O.D. New York. ROTRONIC – The Company I N T R O D U C T I O N LEADING IN HUMIDITY MEASUREMENT ROTRONIC has been manufacturing humidity instruments since 1967. Our products have been developed over the years to provide accurate and dependable measurements in a wide range of applications, at competitive prices, and with features which our customers appreciate. Throughout this catalog, you will find a range of units which solve the measurement requirements in almost any application. All products are developed and manufactured at our headquarters in Switzerland, where we maintain an ISO 9001:2000 quality system, as well as an accredited calibration laboratory, and a full repair facility. We have a worldwide network of subsidiary companies and distributors, who are highly trained to support the ROTRONIC product range. Calibration Mobile – Unique in Europe In some European countries, our customers can benefit from a unique on-site calibration service. With the new dynamic humidity generator FG-431, developed specifically for the calibration mobile, we are able to perform on-site humidity and temperature calibrations that are traceable to National Standards carried out to the usual high ROTRONIC quality directly at your site. Within a short time, a large number of instruments can be calibrated and, if necessary, adjusted. The downtime for customer’s instruments is minimized; additionally, the administration of the calibration is handled efficiently, reducing the workload for the company. On-site calibration using the mobile is cost effective even for a small number of instruments. How it works: Only a 230 VAC mains outlet is required for use by the calibration mobile. A four-point calibration is completed in approximately ten minutes. A calibration certificate traceable to the National Standard is issued with the calibrated instrument. Provided the probe diameter does not exceed 25 mm, even third party instruments can be calibrated with the dynamic calibrator. The calibration range of 0.1…99 %RH with a measurement uncertainty of 0.5…1.5 %RH (depending on the humidity) is unique. We also perform on-site temperature calibrations in the range -25…125 °C with a measurement uncertainty of 0.05…0.2 K (depending on the data interpretation and display resolution). We would be pleased to visit to your site with our calibration mobile! Please check with your local ROTRONIC subsidiary or distributor to see if this service is available in your country. Many famous international organizations place their trust in ROTRONIC measurement systems, our customer list includes: AGFA-GEVAERT BARILLA DEUTSCHER WETTERDIENST ROCHE HONEYWELL KODAK KNORR LG.PHILIPS LCD NASA NESTLÉ PROCTER & GAMBLE SAMSUNG CLARIANT BAYER BOEHRINGER INGELHEIM GLAXO SMITH KLINE HEWLETT PACKARD INTEL JOHNSON CONTROLS MÉTÉO FRANCE METEO SCHWEIZ NOVARTIS PHILIP MORRIS SIEMENS SCHERING PLOUGH 1 I N T R ROTRONIC Technology The measurement of humidity is a complex science, and over many years we have continuously developed our products to provide higher precision, better long term stability and the features our customers demand. There are certain core technologies which are common to many of our products, and which differentiate ROTRONIC instruments from many alternatives in the market: O D U C T I O N Hygromer® Sensor. The Hygromer sensor was introduced in 1979 in response to market demand for higher performance and lower costs. Since its launch, it has constantly been developed using the highest quality materials and the state-of-the-art production techniques. Today it still has the widest operating range of any %RH sensor in the market, working over the ranges of 0…100 %RH and –50…200 °C. Its superb reputation for long term stability is second to none, and many examples can be seen in use after more than 20 years. It is also able to withstand exposure to condensation without affecting calibration. The Hygromer® sensor is used in every product carrying the ROTRONIC brands Hygromer® and HygroClip®. Several versions are available with different characteristics, see page 125 for more information. The HygroClip® Concept. HygroClip® is a humidity and temperature measurement concept utilizing an exclusive digital semiconductor technology. It is based on a custom ASIC*, designed specifically for humidity and temperature measurement applications and works in conjunction with the Hygromer sensor. Products based on HygroClip® technology include features such as probe interchangeability, digital signal processing, digital calibration and much more. HygroClip® technology is used in every product carrying the ROTRONIC HygroClip® brand. * Application Specific Integrated Circuit Custom Mechanical Components The precise measurement of humidity needs careful consideration of temperature. Even the best humidity sensor and electronics cannot compensate for mechanical components that do not respond quickly to temperature changes. Our in-house design team has therefore created a range of custom mechanical components which provide the best combination of mechanical strength and optimum thermal properties to ensure that sensors have the best possible chance of accurate measurements. Compensation Hygrometers are usually only factory adjusted at ambient temperature, so ROTRONIC humidity instruments feature dynamic temperature compensation to ensure that measurement values are optimized across the entire working range. Even if you purchase a transmitter that measures humidity only, you will find a temperature sensor integrated into the probe for this purpose. Our Swiss Calibration Service (SCS) laboratory can provide calibrations at higher or lower temperatures if required. Thanks to the use of the latest digital technology, ROTRONIC humidity instruments can also be specified to include dynamic pressure compensation. Adjustment All ROTRONIC probes are factory adjusted according to the international standards, with a flow rate of 10 l/min and 1m/s at 23 ±5 °C. Only probes with exceptionally large dimensions such as AW-DIO or BFC are excluded from this. The accuracy mentioned in the catalog refers to our calibration laboratory with the Accreditation number SCS065 and the digital probe signal. 2 Dam p G u a rd ® Like bacteria and viruses, molds are micro-organisms. Micro-organisms are present everywhere, and our bodies are constantly exposed to them. Molds thrive well in environments where humidity is in the range of 70...80 %RH. To stop the formation of mold by means of ventilation, it is not enough just to know the room humidity. One also needs to know the humidity at the wall’s surface, as this is where mold will grow. Mold growth in buildings can result in significant repair costs, especially in apartment buildings. Molds produce tiny spores, which are emitted into the air in enormous quantities, and so they can be breathed in. Because of their surface characteristics, these spores can, amongst other things, trigger allergies similar to those caused by pollen from plants. Dampness and molds in closed environments can have a significant effect on occupant health. According to recent research, dampness and mold increase the risk of suffering with asthma by 50%. DampGuard® ● Prevention of damage to walls caused by excessive humidity ● Direct measurement of wall humidity ● Instant detection of condensation ● User friendly indicator of high humidity ● Prevention of moisture related problems in poorly insulated buildings ● Resolution of conflicts between tenants and landlords ● Saves heating costs ● Protects health, ideally suited for people prone to allergies and asthmatics ● Simple to use ● Swiss made DampGuard® works! In representative research, it was established that in Germany alone, almost one third of all dwellings are affected by damage caused by high humidity, 6 to 9 % of them with visible mold. Health authorities, consumer organizations and organizations for the protection of tenants often recommend buying simple hygrometers. In practice, experts could show that mold formation cannot be prevented effectively by using such instruments, as they do not measure the critical surface humidity of the construction material. The effective humidity of the wall and wall coverings can only be measured with the patented DampGuard. In close cooperation with the German laboratory Dr. Missel, ROTRONIC has developed a unique indicator for indoor wall surface humidity measurement. The sensors of the device are in close proximity to the surface. DampGuard® indicates the actual surface humidity by means of simple LEDs, and helps the occupant to manage the critical surface humidity. The current humidity value is displayed by 4 differently colored LEDs on a 4-point scale: LED‘s Humidity Growth of mould Action •• < 70 %RH 70...80 %RH 80…100 %RH 90…100 %RH Not possible Critical range Possible Highly likely none Ventilation Ventilation Ventilation • • • Technical note: In order to ensure accurate determination of the wall surface humidity, the sensor is designed so as to allow the water molecules to diffuse through the sensor. This prevents a microclimate under the sensor. This is possible only with ROTRONIC Hygromer®-sensors. Dam p G u a rd ® Cold air can hold much less moisture than warm air. At 0 °C, the air can hold a maximum of 4.84 g water per cubic meter, which corresponds to a relative humidity of 100 %RH. At an ambient temperature of 23 °C, 100 %RH is equal to 20.5 g/m3 that’s over four times more! Understanding these correlations is important, because it becomes evident that ventilation is always effective in winter time, even if it’s raining outside (outside humidity ~100 %RH). The cold air that is brought into the interior contains less water vapor than the warm interior air. When warming up, the air absorbs water vapor, which is released when ventilating again. Exchange of humidity at different conditions: Exterior Temp / rel. humidity -2 0 °C / 10 0 %RH - 10 ° C / 10 0 %RH 0 ° C / 10 0 %RH 10 ° C / 10 0 %RH Interior Temp / rel. humidity 20 ° C / 7 0 % R H 20 ° C / 5 0 % R H 23 ° C / 7 0 % R H 23 ° C / 5 0 % R H g/m3 1. 07 2.3 6 4.8 4 9.3 9 g/m3 12. 09 8 .63 14. 38 10. 27 Yield from interior to exterior 11.0 2 g/ m 3 6 .2 7 g /m 3 9 .5 4 g/m 3 0 .8 8 g/m 3 Even under the worst conditions, humidity is still transferred from the interior to the exterior, provided the interior conditions are warm. DampGuard® assists in the development of a ventilation plan, which is energy saving and at the same time suppresses the growth of mold very effectively. SPECIFICATIONS: Humidity sensor Capacitive humidity sensor Hygromer® AC-2 Indicators 4 LEDs, green, yellow, red, red Accuracy 80 %RH ± 2 %RH <70 %RH >90 %RH ± 4 %RH <30 %RH ± 6 %RH Adjustment at 80 %RH Display interval 5 seconds Supply 2 x AAA batteries 1.5 V Battery life time approx. 1 year Dimensions 61 x 58 x 50 mm Material ABS Relative wall humidity [%] Stosslüften The diagram above shows a huge surge of humidity in the air during the night hours. During the measurement period ventilation optimization was achieved; and humidity was reduced by approximately 10 %. Protection rating IP50/NEMA5 protection against dust and contact Signal-white RAL 9003 Order code: DampGuard-1 Scope of delivery: Instrument, adjusted, ready for use after inserting the batteries. Includes two batteries, 1 screw and 1 dowel, damp brochure with instruction manual and information regarding the correct use of the DampGuard®. Stosslüften Absolute humidity [g/m3] Color Absolute wall humidity [g/m3] This diagram shows that the wall surface climate cannot be changed simply by ventilation. The reason is a high degree of humidity in the wall. In such case, one should contact the landlord or install a dehumidifier. Contents Section Handheld Instruments I Products: Pages HygroPalm, HygroClip probes, S1, GTS 6 - 15 N T R O D Data Loggers HygroLog NT, HygroLog, HygroClip probes, Agent D, Agent probes 16 - 31 U C T Transmitters HygroFlex, M-Series, Roline L Series HygroClip, RO-DP60, RO-DP100, Hygrostat MB 32 - 71 I O N Meteorology Weather protection, MP100/400, MP100/400H, Mounting hardware 72 - 79 Water Activity HygroLab, AW Quick, AW-DIO, HygroClip probes HygroPalm AW1 80 - 91 Temperature Temperature Transmitters and Handhelds 92 - 95 OEM Products HygroClip, OEM options 96 - 99 Calibration SCS calibration standards, humidity generators, calibration devices 100 - 105 Software and Bus systems HW3, HW4 Features and options Bus systems 106 - 113 Accessories Filters, mounting hardware, cables etc. 114 - 119 Theory Sensors, definitions, pollutant tables 120 - 126 Index A BC… Z 127 5 H A N D H E L D I N S T R U M E N T S Introduction Measurement of humidity and temperature is very important in many production, storage, transportation and test applications. Many processes can only be performed, or goods correctly stored, if humidity and temperature conditions are within a specific range. Materials and products may not behave correctly, or can even degrade, if climatic conditions are incorrect. ROTRONIC handheld instruments are the perfect tool for spot checks, which must be the first step in defining ambient conditions and solving humidity or moisture related problems. Our handheld instruments are highly accurate, and include many useful features, yet they are easy to use and maintain. Configuration and calibration is carried out in the factory, so they are ready for immediate use on delivery. Certain models offer the facility to change the instrument’s configuration to suit specific application needs, either with user friendly software, or the integrated keypad. A range of interchangeable probes means application flexibility, simple maintenance and convenient calibration. Key Features Your Benefits ● Accuracy and long term stability ➤ Reliable data and less frequent calibration ● Interchangeable digital sensor modules ➤ Simple calibration and maintenance ● Wide range of digital probes ➤ One instrument – many applications ● Ergonomic and modern instruments ➤ Comfortable to use and handle ● Large display with good contrast ➤ Clear observation of measured values ● HOLD Function ➤ To capture measured values ● Battery powered ➤ Suitable for use anywhere Section contents HygroPalm Handheld Instruments for HygroClip probes ● ● ● ● ● Interchangeable probes Large easy-to-read display Optional Docking Station Temperature adaptors for Pt100 probes RS232 Interface HygroClip Probes for HygroPalm Handhelds ● ● ● ● ● ● ● ● 12/13 Sword probe for paper stacks Sets in practical carry cases Plate probe Accessories and Sets of HygroPalm Instruments ● 10/11 Wide range of options to suit any application 0…100 %RH, -50…200 °C 100 % interchangeable without adjustment Instruments for the Paper Industry 6 8/9 Complete equipment for measuring and calibration Handy cases Connecting cables 14 Handheld Applications Building Management /HVAC Accurate and reliable thermo-hygrometers are needed to verify correct system performance during commissioning. The ability of ROTRONIC handhelds to be calibrated on-site and their high accuracy certifies ROTRONIC instruments for this kind of applications. Climatic Test Cabinets Many products are tested over a variety of climatic conditions. The exceptionally wide measuring range of the ROTRONIC handheld units means these test conditions can be easily checked. Paper Industry The first ROTRONIC products were developed for the paper industry, and today we have the largest world-wide sales of sword hygrometers for paper stack ERH measurement. Health and Fitness Centers, Hospitals, Classrooms In public areas it is especially important to maintain correct humidity values to minimize health risks. H A N D H E L D Research Many research tests must have the humidity conditions defined for the results to be accepted or considered to be reliable. I N S T R U M E N T S Museums, Libraries and Art Galleries Conservation applications require dependable measurements and low cost of ownership. ROTRONIC handhelds have been a mainstay in this market for three decades. Warehouses and Storage Many products need to be stored in certain conditions to remain in good condition. Industrial Process Monitoring The maximum measurement temperature of 200 °C and the robust design of our probes means that even the most difficult process application can be checked with a ROTRONIC handheld. 7 H A N D H E L D I N S T R U M E N T S HygroPalm Series Humidity and Temperature Display Instrument for digital HygroClip®‚ Probes HygroPalm represents a new generation of portable humidity/temperature instruments, utilizing the very latest digital technology. The advantage of digital technology is clear; highest precision is assured as a result of digital signal processing and data transmission in a digital format, which means that signal loss over extended cable lengths and external interference cannot influence measured values. Calibration data is maintained within the probe itself, which means there is no need to calibrate the whole system when a probe change is required, and probes for different applications can be fitted in seconds. The HygroPalm 0 is a value engineered instrument designed to be cost effective, yet still provide high measurement performance. By removing some of the more advanced HygroPalm features such as probe interchangeability and external interface connections, the HygroPalm 0 is the perfect entry level instrument, yet maintains the core ROTRONIC values of high precision and excellent long term stability. Essential functionality such as dew point / wet bulb computation, keypad calibration adjustment and battery recharging options are retained to make the HygroPalm 0 the ideal balance of performance and price. HygroPalm 1, 2 and 3 feature interchangeable probes. New probes for changing measurement tasks can be installed in seconds. HygroPalm 0 Key features: • • • • • • • • Cost effective instrument 0…100 %RH, -10…60 °C Integrated probe Standard alkaline batteries or rechargeable Display of dew point or wet bulb temperature One-point calibration with keypad Optional docking station for battery recharging Large clear LC-display Order Code: HygroPalm 0 HygroPalm 1 The instrument has the same features as HygroPalm 0, but features interchangeable probes and additional functions: Key features: • Service interface for HygroFlex transmitters • One-point adjustment with keypad • Measurement range -50…200 °C (probe dependent) Order Code: HygroPalm 1 (probe must be ordered separately) HygroPalm 2 Key features: • • • • • • All functions of HygroPalm 1 Second probe input %RH and °C Multiple point probe adjustment RS232 PC interface Calculation of various psychrometric parameters Formula Editor for customer specific calculations Order Code: HygroPalm 2 (probe must be ordered separately) HygroPalm 3 Key features: • • • • All functions of HygroPalm 2 Universal input for pressure, air speed etc. Dynamic pressure compensation for calculations (requires pressure probe) Bi-directional interface for HygroFlex transmitters Order Code: HygroPalm 3 8 (probe must be ordered separately) HygroPalm H A N D H E L D HygroPalm Feature Overview Highly precise, stable humidity and temperature sensors Interchangeable probes Calibration can be updated, or the range of the application met by the simple connection of a different probe. I N S T R U M E N T S Interface connector for HygroFlex transmitters Large display with trend indicators for easy reading Universal probe input HOLD function for freezing the display Psychrometric calculations available Option: Lock 5-button keypad for easy operation Docking station Socket for power adaptor RS232 interface for use with a PC Battery charging 9 H A N D H E L D I N S T R U M E N T S HygroClip Probes for HygroPalm A range of probes for different applications are available for the HygroPalm instruments. All probes are based on digital HygroClip technology, and can be interchanged within seconds without the need for recalibration. With special adaptor cables, even probes designed for Industrial applications can be used (see pages 27 and 119). HygroClip S Standard probe for humidity and temperature. A wire mesh filter provides sensor protection against dust and high air velocity. Dimensions Ø15 x 100 mm. IP rating: IP65/NEMA4 Measurement range: -40…85 °C, 0…100 %RH Accuracy: Standard: ±1.5 %RH, ±0.3 K (at 23 ±5 °C) Output: ROV analog and DIO digital signal Order Code: HygroClip S Standard probe with certificate of conformance N.I.S.T. traceable Certificate of Calibration available on request. HygroClip SC04 / SC05 4 or 5 mm diameter cable mounted probes for humidity and temperature measurements in small spaces such as product and packaging testing, concrete, electronic test and climatic chambers. Cable length 2m Measurement range: Accuracy: Output: Recommended application range: -40…100 °C , 0…100 %RH ±1.5 %RH, ±0.3 K (at 23 ±5 °C) ROV analog and DIO digital signal -40...40 °C: 0...99 %RH / 40...100 °C: 0...70 %RH Order Code: HygroClip SC04 HygroClip SC05 Ø 4 x 2000 mm cable probe Ø 5 x 2000 mm cable probe HygroClip HK 25 / HK40 High temperature probe for measurements in ducts, dryers, climatic chambers etc. Probe length 250 or 400 mm. Measurement range: HK25: -50…150 °C, 0…100 %RH HK40: -50…200 °C, 0...100 %RH Accuracy: ±1.5 %RH, ±0.3K (at 23 ±5 °C) Output: ROV analog and DIO digital signal Wire mesh filter: Included. Other filters must be ordered separately! See page 114. Order Code: HygroClip HK 25 (250 mm probe, max. 150 °C, standard) HygroClip HK40 (400 mm probe, max. 200 °C, standard) HygroClip HK 25-B5 With Binder 5-pin connector HygroClip HK40-B5 With Binder 5-pin connector 10 HygroClip Probes for HygroPalm HygroClip SP05 Fast response 5 mm diameter insertion probe with laser cut air slots, suitable for use bulk goods such as corn, wheat and granules. Also suitable for measurements in concrete and brick. Not suitable for powders. Probe length 200 mm. Measurement range: -40…85 °C, 0…100 %RH, Accuracy: ±1.5 %RH, ±0.3 K (at 23 ±5 °C) Output: ROV analog and DIO digital signal Order Code: HygroClip SP05 HygroClip SP05-B5 Standard probe with Binder 5-pin connector H A N D H E L D I N S T R U M E N T S HygroClip HP28 Robust 10 mm diameter tubular probe for measurements in bulk products such as powders and granules. Probe length 280 mm, 2m cable, steel sinter filter. Measurement range: -40…85 °C, 0…100 %RH Accuracy: ±1.5 %RH, ±0.3 K (at 23 ±5 °C) Output: ROV analog and DIO digital signal Order Code: HygroClip HP28 HygroClip HP28-B5 Standard with Binder 5-pin connector HygroClip HS28 Sword Probe For measurements in paper stacks and rolls. Lightweight, yet robust aluminum blade for fast temperature and humidity equilibrium. Sword blade 280 x 18 x 4 mm, Measuring range: Accuracy: Output: -40…85 °C, 0… 100 %RH ±1.5 %RH, ±0.3 K (at 23 ±5 °C) ROV analog and DIO digital signal Order Code: HygroClip HS28 HygroClip HS28-B5 Standard with Binder 5-pin connector 11 H A N D H E L D I N S T R U M E N T S Instruments for the Paper Industry HygroPalm 2-Set-HS28 • • • • HygroPalm 2 handheld instrument HygroClip HS28 sword probe Calibration device EGS, for sword probes Humidity standard EA50-SCS (5 ampoules 50 %RH with SCS certificate) • Robust carrying case AC1117 • Software HW3 • Connection cable AC1622 Order Code: HygroPalm 2-Set-HS28 Suitable for: Paper processing industry Cut sheet material GTS and GTS-Set The GTS is a classic ROTRONIC product which has stood the test of time. It was designed specifically for the measurement of humidity and temperature within stacks of paper, cardboard or any other cut sheet material. The robust design, in combination with updated electronics make the GTS the most popular instrument for paper and card applications. GTS – for paper and cardboard stacks Main features: • Display of relative humidity or temperature • Strong but lightweight aluminum sword for fast equilibrium • Simple one button operation • Auto power off function • Low battery indicator Order code: GTS Measurement set for cut sheet material includes: • • • • GTS instrument Robust carrying case AC1102 Calibration device EGS Humidity standard EA50-SCS (5 ampoules 50 %RH with SCS certificate) • adjustment screw driver Order code: GTS-Set 12 Instruments for the Paper Industry PS1 for paper stack measurement Another classic design which we retain thanks to continuing demand from our customers: • • • • • • • • • Sword probe for equilibrium relative humidity and temperature Adjustable probe position Large, clear display Simple operation Hold function Auto power off Battery status indicator Battery operation Temperature display in °C or °F Order Code: PS1 Set V-701-S1 H A N D H E L D I N S T R U M E N T S Handheld instrument with integrated sword probe carrying case and calibration device Carry case for the S1 Plate probe for on-line ERH measurement on paper webs Complementary to the handheld instruments for the paper industry, ROTRONIC also manufacture a unique on-line ERH measurement probe, which can be used either with a handheld instrument or with a transmitter. Key Features ● Your Benefits On-line measurement of equilibrium humidity ➤ Enables on-line control of production process ● Continuous operation ➤ Minimizes further work for quality control ● Temperature compensated ➤ Accurate measurement at temperature variations ● Combined %RH °C measurement ➤ Both values available simultaneously ● Compatible software for data logging ➤ Independent data for analysis and reporting Detailed information for this probe may be found in the Transmitter section of this catalog (see page 38) Docking Station for HygroPalm instruments PalmDock Docking Station • Benchtop docking station designed for use with all HygroPalm models with RS232* PC interface and power connection (with external power adaptor). • HygroPalm 1 does not feature an RS232 interface. Order Code: PalmDock-1 Docking station for battery charging, incl. RS232 cable, HW3 Software & ACA, 9-volt adapter * Further information in the chapter HW3 Software 13 H A N D H E L D I N S T R U M E N T S Handheld Accessories and Sets Measuring instruments often need to be transported to site, or from building to building. Handheld measurement sets package together the most commonly used standard equipment and accessories. Carry cases are also useful for storing instruments, and help to maintain long-term stability by protecting the units from mechanical damage or contamination when being transported or stored. HygroPalm 1-Set: • • • • HygroPalm 1 handheld instrument HygroClip S probe Calibration device ER-15, suitable for HygroClip S Humidity standards EA50 (5 ampoules 50 %RH with SCS certificate) • Robust carrying case AC1116 • Suitable for facilities managers, HVAC technicians, surveyors. Order Code: Palm 1-Set HygroPalm 3-Set: • • • • HygroPalm 3 handheld instrument HygroClip S probe Calibration device ER-15, fitting for HygroClip S Humidity standard EA50 (5 ampoules 50 %RH with SCS certificate) • Robust carrying case AC1116 • Suitable for: Users who want to record measured values and calibrate their probes using a PC Order Code: Palm 3-Set Temperature adaptors for Pt100 probes Using these adapters, the HygroPalm can accept Pt100 probes either in probe input 1 using the TH100-DAT05, or via probe input 2 (where fitted) using TH100-B5 (standard Binder connector) see page 93 for a range of compatible Pt100 probes. Order Code: HygroClip TH100-DAT05 HygroClip TH100-B5 Special order: for HygroPalm 1, 2 and 3, probe input 1 for HygroPalm 2 and 3, probe input 2 North American Market Air velocity probe Mini Air6 Mini Air 6 can be connected to the HygroPalm 3 as well as to compatible data loggers and industrial transmitters Measuring range: 0.3 - 20 m/s Temperature range: -10…+80 °C Output signal: 0.03…2.0 V = 0…20 m / s Head-Size: Ø 22 x 28 mm Probe length 175 mm, cable length 5 m Order code: MiniAir6 Mini 20M-S Other air velocity probes are available on request. Special order: North American Market 14 Technical Data Summary H A N D H E L D Technical Data Features Humidity sensor Hygromer® HygroPalm 0 / 1 HygroPalm 2 HygroPalm 3 HygroClip S probes with Hygromer®‚ AC-1 Sensor (except HygroPalm 0: fixed probe, non-interchangeable) Temperature sensor Pt 100 1/3 DIN Probe connections (combined %RH/ °C) 1 2 Signal input 1 digital 2 digital 2 digital or 4 analog ROV* Input for 3rd party probe No 0…2.5 V Supply for 3rd party probe 9 V / 10 mA RS232 Interface No Yes Display 3-line alphanumeric LCD Formula Editor Remote Transmitter Interface Transmitter adjustment Adjustment against reference probe Transmitter measurement display Transmitter status display Specifications %RH, °C, °F, calculated parameters Selectable No Yes 0.1 %RH / 0.1 °C, calculated parameters 0.01 By Keypad No N/A N/A By Keypad or HW3 software By Keypad or HW3 software Yes No Yes Manually with software/ constant Yes No No No No Yes HygroPalm 1 only Yes No Yes Dynamically with probe input and manual 0…100 %RH, non condensing / -10...+60 °C Measuring ranges (probes) Probe dependent 0...100 %RH / -50…200 °C Accuracy at 23 °C** Reproducibility Long term Stability Power Supply 9 V PP3 alkaline battery 9 V rechargeable battery External supply voltage 8…20 VDC Type of enclosure/ IP Rating Housing material Dimensions in mm Weight (approx.) Dimensional Diagrams Accuracy of probe < 0.5 %RH / <0.1K < 1 %RH / Year No third party probe input No No No %RH 3 digit LCD °C. 3 ½ digit LCD %RH, °C, °F No By potentiometer No 35 / 80 / 10 % N/A 3-digit LCD (%RH or °C) %RH, °C, °F N/A 35 / 80 % No No No No No 0…100 %RH -10…50 °C 5…99.9 %RH 5…99.9 %RH -25…75 °C -10…50 °C ±2 %RH / ±0.3 K(±2.5 <15 %>90 %) No No Yes No 190 x 63 x 26 350 g S1 420 x 70 x 40 400 g GTS 40 86 298 72 15 18 65 27 ENTER 4 62.8 150 MENU 5 S1 191 188 274 196 18 * ROV = 0…1 V = 0…100 %RH/ -0.40 V…+0.85 V = -40…+85 °C ** HygroPalm 0: = ±1 %RH / ±0.3 K (at 23 ±5 °C) I N S T R U M E N T S Integrated probe No Operating ranges (electronics) 72 Hygromer® AC-1 No No Yes Yes Yes On docking station IP 50 / NEMA5 ABS 195 x 70 x 35 300 g HygroPalm 0 HygroPalm 1,2,3 GTS 260 Display units Display in Aw Resolution Probe adjustment 1 point %RH, °C 4 point %RH, 2 point °C 3-point %RH, T min/T max 2-point %RH, T min /T max Calculation & unit display Dew point and wet bulb temperature Full psychrometric calculation Pressure compensation of calculated values PS1 ~40 57 15 Introduction D A T A L O G G E R S Long term recording of humidity and temperature measurements is essential in many production, storage, transportation, display and test applications. They provide valuable information on the levels and variation of humidity and temperature which can have a significant impact on people, materials and objects. Compliance with the regulatory requirements GxP, 21 CFR part ll, EV GMP and the observation of established recommendations such as GAMP4 is considered essential, especially in the pharmaceutical and food industries. The HygroLog NT is ROTRONIC’s next generation datalogger. It has been newly developed to meet regulatory requirements, and to provide a range of features and functionality to satisfy even the most demanding needs. To complement this new product, a new software package has been developed to suit. It has functionality which is unique to modular data logger modules. The ROTRONIC range of data loggers and recorders are highly accurate and stable, but are easy to use and maintain. Configuration and programming can easily be performed by any operator, with user friendly software or integrated keypads. Data can be presented in a graphical or statistical format. A wide range of interchangeable probes means simple maintenance and application flexibility. Key features Your benefits ● Compact stand alone modules ➤ Easy to install and flexible ● Measurement display ➤ Easy observation of current values and alarm indicators ● Accuracy and long term stability ➤ Reliable data and reduced maintenance ● Interchangeable sensor modules ➤ Easy calibration and maintenance ● Wide range of probes ● Robust IP65/NEMA4 housing with shock protection ● Battery / rechargeable battery powered ● Custom mounting hardware ● Flash Card memory ● User friendly software ● Compliance with requirements for electronic records and signatures FDA 21CFR Part 11 ➤ One logger – many applications ➤ Suitable for industrial use. ➤ No installation costs and can be easily relocated ➤ Professional installation ➤ Practically unlimited recording time ➤ Easy to learn and use ➤ High quality assurance Section contents HygroLog NT – the new logger generation ● ● ● ● ● ● ● ● ● 16-23 Integrated or interchangeable probes Integrated display (optional) Alarm function Easy-to-use by keypad or software Compliance with requirements for electronic records and signatures FDA 21CFR Part 11 Interchangeable compact flash card memory for virtually limitless number of measurement values Probe adjustable directly in logger Docking stations for extended options Networkable HygroLog and HygroLog-D data loggers for HygroClip probes ● ● ● ● HygroClip probes for HygroLog data loggers ● ● ● 25-26 Wide range of options to suit any application 0…100 %RH, -50…200 °C 100% interchangeable without adjustment Accessories for data loggers ● ● ● ● ● ● ● ● 27 Installation hardware Impact protection Connecting cables Power supplies Agent D data logger for humidity and temperature 16 24 Interchangeable probes Integrated display Alarm function Validated, easy-to-use software 64,000 point memory Multi channel temperature only version EX- rated External start feature for instruments without keypad 30-31 Data l og ge r a ppl i ca t i on s D A T A L O Store rooms and warehouses G Museums, libraries and art galleries G E R S Clean rooms Controlled environments & cabinets Production areas Transportation 17 HygroLog NT D A T A L O G G E R Humidity and temperature logger for digital HygroClip® probes. The HygroLog NT-Series is a completely new range of advanced dataloggers, designed to meet and exceed today’s functional, performance and regulatory needs. Using flash-card memory, their logging capacity is virtually limitless, and the state-of-the-art digital electronics takes measurement performance to a higher standard. Data maybe stored in two different ways: In simple text mode or in protected mode, readable only by HW4 software. In text mode, 25,000 data records may be recorded per MB storage capacity of the flash card; in protected mode, 47,000 records per MB. Digital data communications guarantees best possible performance, 0 is always 0, and 1 is always 1, so accuracy of data transfer is absolute, and calibration can be maintained using digital probe interchangeability. Should you need to change the logger’s application, a range of alternative probe types can be connected without further need for calibration or loss of performance. The HygroLog NT loggers and HW4 software record all events such as configuration changes, battery replacement, operator intervention or change of the memory card. This meets the electronic record and signature requirements of compliance regulations such as FDA 21 CFR Part 11 and the industry equivalents GxP. More information regarding software can be found in the Software section of the catalog (pages 106 to 111) S HygroLog NT1 Data logger with integrated humidity/temperature sensor. Features • • • • • • • • • • • • Flash-card memory for virtually unlimited logging Data retrieval by card reader, PDA or PC with HW4 software or docking station 16 MB flash card included, extendable up to 1 GB Digital signal processing for maximum precision Real time clock Logging interval selectable from 5 s to 24 h Operation with batteries or rechargeable batteries Selectable logging modes, such as start/stop, text and protected mode Operating range: 0…100 %RH; -30 …70 °C; with display -10...60 °C Accuracy: ±1.5 %RH / ±0.3 K (at 23 ±5 °C) LED status indicator Optional display and keypad for actual measurement values, status, operation, adjustment and to view of logged data Options connected via optional docking station: Additional features when used with optional docking stations: (see pages 22...23) • Power supply and battery charge by mains adaptor AC1211 via docking station • RS232, RS485, USB and Ethernet wireless interfaces for networking and data retrieval • Connection of up to 4 additional analog or digital probes • Connection of up to 4 additional Pt100 probes • 2 digital inputs for the monitoring of doors etc. • 2 power-switching relays for simple control or alarm functions Order code: Special order: 18 North American Market HygroLog NT D A Features Overview T A L O Integrated or interchangeable probe G G Optional inputs compatible with Industrial probes E R S Full graphic display (optional) Optional inputs for Pt100 probes Networkable Lockable mounting option PDA-compatible Flash Card enables rapid data transfer Easy operation with keypad Battery charge function when in docking station Shockproof IP 65/NEMA4 housing USB / Bluetooth interface (optional) Audit trail – protected, Excel compatible data, suitable for pharmaceutical and chemical industries 19 HygroLog NT D A T A L O G G E R S HygroLog NT2 Data logger for single interchangeable humidity/temperature probe Features: • • • • • • • • • • • • • • Flash-card memory for virtually unlimited logging Data retrieval by card reader, PDA or PC with HW4 and docking station 16 MB flash card included, extendable up to 1 GB Digital signal processing for maximum precision Real time clock Logging interval selectable from 5 s to 24 h Operation with batteries or rechargeable batteries (recommended) Selectable logging modes, such as start/stop, text and protected mode Operating range: 0...100 %RH; -30 ...70 °C; with display -10...60 °C Measuring range: probe dependent, max. -50...200 °C Accuracy: probe dependent Probe adjustable in logger LED status indicator Optional display and keypad for actual measurement values, status, operation, adjustment and for viewing logged data • Remote display of measurement values by a second HygroLog NT for loggers without display • Audible alarm (beeper) HygroLog NT2 and NT2-D are shipped with an integrated HygroClip S probe. Further probes see pages 25-26 Order code: HygroLog NT2 HygroLog NT2-NP HygroLog NT2-D HygroLog NT2-D-NP MOK-xx-B5* MOK-xx-DAT05* Logger for interchangeable probe, without display Logger, no display Probe must be ordered separately, see pages 25-26 Logger for interchangeable probe with full graphic display, probe and keypad Logger, full graphic display and keypad Probe must be ordered separately, see pages 25-26 MOK-DS-ETH Adaptor cable for HygroClip probes with B5 connector Adaptor cable for HygroClip probes with DAT05 connector *xx= length in m. Available lengths: 1 m, 2 m, 5 m Probe adaptor cable for Ethernet docking stations HW4-E HW4-P HW4-OPC HW4-VAL Standard software for programming and data management Professional software with additional validation functions HW4-P with OPC server functionality HW4-OPC with complete validation documentation Options Additional features for HygroLog NT2 when used with optional docking stations: see pages 22-23 • Networkable via Ethernet /RS485 in master/slave mode • RS232, USB and RS485 interface • Connection of up to 4 additional analog or digital probes • Connection of up to 4 additional Pt100 probes • 2 digital inputs for the monitoring of doors etc. • 2 power-switching relays for simple control functions • Supply by mains adaptor AC1211 via docking station • Power supply to slaves via the RS485 network cable is possible Note: The Ethernet docking stations tend to self-heat due to the power consumption of the Ethernet module. You may wish to use the adaptor cable MOK-DS-ETH for probe 1, in order to separate the probe and module and prevent measurement errors. 20 HygroLog NT D A HygroLog NT3 T Data logger for up to 3 interchangeable humidity/temperature probes. 1 internal probe (interchangeable), 2 additional probes may be connected using an adaptor cable MOK-xx-B5. A Features: L • • • • • • • • • • • • • • Flash-card memory for virtually unlimited logging Data retrieval by card reader, PDA or PC with HW4 and docking station 16 MB flash-card included, extendable up to 1 GB Digital signal processing for maximum precision Real time clock Logging interval selectable from 5 s to 24 h Operation with batteries or rechargeable batteries (recommended) Selectable logging modes, such as start/stop, text and protected mode Operating range: 0...100 %RH; -30 ...70 °C; with display -10...60 °C Measuring range: probe dependent, max. -50...200 °C Accuracy: probe dependent Probe adjustable in logger LED status indicator Optional display and keypad for actual measurement values, status, operation, adjustment and for viewing logged data • Remote display of measurement values by a second HygroLog NT for loggers without display • Audible alarm (beeper) O G G E R S HygroLog NT3 and NT3-D are shipped with an installed HygroClip S probe. Further probes see pages 25...26. Order code: HygroLog NT3 HygroLog NT3-NP HygroLog NT3-D HygroLog NT3-D-BT HygroLog NT3-D-NP MOK-xx-B5* MOK-xx-DAT05* Logger for interchangeable probe, without display Logger, no display Probes must be ordered separately, see pages 25-26 Logger for interchangeable probe with full graphic display, probe and keypad Logger for interchangeable probe with full graphic display, probe, keypad and Bluetooth interface Logger, full graphic display and keypad Probes must be ordered separately, see pages 25-26 MOK-DS-ETH Adaptor cable for HygroClip probes with B5 connector Adaptor cable for HygroClip probes with DAT05 connector *xx= length in m. Available lengths: 1 m, 2 m, 5 m Probe adaptor cable for Ethernet docking stations HW4-E HW4-P HW4-OPC HW4-VAL Standard software for programming and data management Professional software with additional validation functions HW4-P with OPC server functionality HW4-OPC with complete validation documentation Options Additional features for HygroLog NT3 when used with optional docking stations: (see pages 22-23) • Networkable via Ethernet /RS485 in master/slave mode • RS232, USB and RS485 interface • Connection of up to 4 additional analog or digital probes • Connection of up to 4 additional Pt100 probes • 2 digital inputs for monitoring of doors etc. • 2 power-switching relays for simple control functions • Supply by mains adaptor AC1211 via docking station • Supply by RS485 network cable possible Note: The Ethernet docking stations tend to self-heat due to the power consumption of the Ethernet modules. You may wish to use the adaptor cable MOK-DS-ETH for probe 1, in order to separate probe and module and prevent measurement errors. 21 Options for HygroLog NT-Series D A T A The docking stations for the HygroLog NT-series serve various purposes: Depending on the model, a docking station may be a simple bracket for wall mounting, a power supply module, an interface module for Ethernet, RS485, USB, RS232, Wireless LAN or an expansion module to add further probes. With the exception of DS-NT0, all docking stations feature a connector for an external power supply using AC1211 mains adaptor (order separately). L O G G E R S 22 DS-NT0 Wall mount bracket, no electronics DS-NT1 Wall mount bracket, connector for external supply DS-NT2 Connector for external supply, RS232 & RS485 interface DS-NT3 Connector for external supply USB & RS485 interface DS-NT4 Connector for external supply Ethernet TCP/IP RJ45 & RS485 interface 2 digital inputs DS-NT4-WL Connector for external supply Wireless LAN TCP/IP & RS485 interface 2 digital inputs DS-U1 Connector for external supply, RS232 & RS485 interface 4 digital or analog probe inputs configured for 0...2.5 VDC 2 digital inputs DS-U2 Connector for external supply, USB & RS485 interface 4 digital or analog probe inputs configured for 0...2.5 VDC 2 digital inputs DS-U4 Connector for external supply Ethernet TCP/IP RJ45 & RS485 interface 4 digital or analog probe inputs configured for 0...2.5 VDC 2 digital inputs DS-U4-WL Connector for external supply, Wireless LAN TCP/IP & RS485 interface 2 digital or analog probe inputs configured for 0...2.5 VDC 2 digital inputs DS-U4-4-20 Connector for external supply Ethernet TCP/IP RJ45 & RS485 interface 4 digital or analog probe inputs configured for 0(4)...20 mA current signals 2 digital inputs DS-PT2 Connector for external supply, USB & RS485 interface 4 Pt100 probe inputs 2 digital inputs Options for HygroLog NT-Series D A T A L O G G E DS-PT4 Connector for external supply, Ethernet TCP/IP RJ45 & RS485 interface 2 Pt100 probe inputs 2 digital inputs DS-PT4-WL Connector for external supply Wireless LAN TCP/IP & RS485 interface 2 Pt100 probe inputs 2 digital inputs DS-R1 Connector for external supply USB &RS485 interface 2 digital inputs 2 relay outputs R S All docking stations, with a logger attached, can be mounted onto a wall; or used on a bench when combined with NT-Desk. Further accessories for HygroLog NT: Order code: MOK-xx-DAT05* MOK-xx-B5* Probe adaptor cable for HygroClip probes with DAT05 connector Adaptor cable for HygroClip probes with B5 connector *xx= length in m. Available lengths: 1 m, 2 m, 5 m MOK-DS-ETH Adaptor cable for Ethernet docking stations HW4-E HW4-P HW4-OPC HW4-VAL Standard software for programming and data management Professional software with additional validation functions HW4-P with OPC server functionality HW4-OPC with large validation documentation NT-Desk Desktop stand for HygroLog NT when combined with a docking station AC1211 Mains adaptor for docking stations (European) 12 VDC /200 mA, with adaptors for USA & UK AC-NT16MB AC-NT32MB AC-NT64MB Flash Card 16 MB, industry type -40...85 °C Flash Card 32 MB, industry type -40...85 °C Flash Card 64 MB, industry type -40...85 °C 15.08.6238 Flash Card Reader incl. USB cable and driver 11.01.6218 11.02.8818 AC1614-02 21.15.0601 RS232 data cable 1.8 m Docking Station < > PC Standard USB cable type A-B, 1.8 m RS485 cable for HygroLog NT, used for cabling via terminal box Patch cable cat. 5e UTP, crossover ET-409 AC-NT-REM 4-pin Binder connector for RS485 network Remote cable for loggers without display 23 D A T A L HygroLog and HygroLog D Humidity and Temperature logger for digital HygroClip® probes. The HygroLog data logger uses the HygroClip range of digital probes for long term recording of humidity and temperature conditions. By using the digital signal output from the HygroClip probes, measurement precision is optimized with no signal loss over extended cable lengths and no external interference can influence measured values. Calibration data is maintained within the probe, which means there is no need to calibrate the whole system, and probes can be interchanged in seconds. In conjunction with the HW3 software, the HygroLog can be supplied with full validation documentation. O G G E R S HygroLog Self contained data logger for HygroClip® digital probes Key features: • • • • • • Stores up to 2 x 5000 values for humidity and temperature Digital signal processing for maximum accuracy Logging interval from 15 seconds to 2 hours Standard alkaline batteries Operating modes selectable: start/stop or loop mode Operating range logger: 0…100 %RH; -30 …70 °C (Battery dependent; with alkaline batteries -10…50 °C) • Measuring range probes: -50…200 °C, probe dependent • Backup battery for data protection on Pcb Order code: HygroLog HygroLog1 w/HygroClip-S probe HygroLog w/o probe (probe must be ordered separately) HygroLog-D Humidity and temperature data logger with LCD display for HygroClip® digital probes Key features: • Stores up to 2 x 5000 values for humidity and temperature • Digital signal processing for maximum accuracy • Logging interval from 15 seconds to 2 hours • Standard alkaline batteries • Operating modes selectable: Start/stop or loop mode • Operating range Logger: 0…100 %RH; -10 …50 °C • Operating range probes: -50…200 °C (probe dependent) • Visual alarm indicators on LCD for temperature and humidity • Battery status display • Status display saving / busy • Backup battery for data protection on Pcb Order code: HygroLog-D HygroLog-D-1 w/HygroClip-S probe HygroLog-D w/o probe (probe must be ordered separately) Software HW3 and Data Cable (FDA CFR 21 Part 11 compliant) The validated HW3 software is used for logger programming as well as to retrieve data. Data may be displayed in a table or graph form. A language editor allows the user to translate the text into his own language. Psychrometric calculations such as dew point may also be performed within the software, and the option to show these values graphically is also included. Calculations may be executed by using a pressure constant or, depending on the instruments connected, dynamically with a pressure probe. As the software can also be used with the full ROTRONIC product range, it offers a variety of other features, such as sending e-mails in case of alarms, data archiving, etc. Of course, measurement data can also be exported to MS Office applications. For extended description see the software section of this catalog. Order code: HygroData HL 24 For HygroLog and HygroLog-D Cable and HW3 software HygroClip Probes for HygroLog Data loggers A range of probes for different applications are available for the HygroLog Data loggers. All probes are based on digital HygroClip technology, and can be interchanged within seconds without need for recalibration. With special adaptor cables, even probes designed for Industrial transmitters may be used. A T A HygroClip S Standard probe for humidity and temperature. A wire mesh filter provides sensor protection against dust and high air velocity. Dimensions Ø15 x 100 mm. IP rating: IP65/NEMA4 Measurement range: -40…85 °C, 0…100 %RH Accuracy: Standard: ±1.5 %RH, ±0.3 K (at 23 ±5 °C) Output: ROV analog and DIO digital signal Order Code: HygroClip S D Standard probe with factory certificate of conformance N.I.S.T. traceable Certificate of Calibration available upon request L O G G E R S HygroClip SC04 / SC05 4 or 5 mm diameter cable mounted probes for humidity and temperature measurements in small spaces such as product and packaging testing, concrete, electronic test and climatic chambers. Cable length 2 m. Measurement range: Accuracy: Output: Recommended application range: -40…100 °C , 0…100 %RH ±1.5 %RH, ±0.3 K (at 23 °C) ROV analog and DIO digital signal -40...40 °C: 0...99 %RH / 40...100 °C: 0...70 %RH Order Code: HygroClip SC04 HygroClip SC05 Ø 4 x 2000 mm cable probe Ø 5 x 2000 mm cable probe HygroClip HK 25 / HK40 High temperature probe for measurements in ducts, dryers, climatic chambers etc. Probe length 250 or 400 mm. Measurement range: HK25: -50…150 °C, 0…100 %RH HK40: -50…200 °C, 0...100 %RH Accuracy: ±1.5 %RH, ±0.3K (at 23 ±5 °C) Output: ROV analog and DIO digital signal Wire mesh filter: Included. Other filters must be ordered separately! See page 114. Order Code: HygroClip HK 25 HygroClip HK40 HygroClip HK 25-B5 HygroClip HK40-B5 (250 mm probe, max. 150 °C, standard) (400 mm probe, max. 200 °C, standard) With Binder 5-pin connector With Binder 5-pin connector Adaptor cable MOK-02-B5 Adaptor cable for probe inputs with Binder 5-pin connector (screw-in type for NT2, NT3 and docking stations) Order code: MOK-02-B5 2 m cable length Calibration devices and humidity standards see page 114/117 25 D A T A L O G G HygroClip probes for HygroLog data loggers HygroClip SP05 Fast response 5 mm diameter insertion probe with laser cut air slots, suitable for use in bulk goods such as corn, wheat and granules. Also suitable for measurements in concrete and brick. Not suitable for powders. Probe length 200 mm. Measurement range: -40…85 °C, 0…100 %RH, Accuracy: ±1.5 %RH, ±0.3 K (at 23 ±5 °C) Output: ROV analog and DIO digital signal Order Code: HygroClip SP05 HygroClip SP05-B5 Standard probe With Binder 5-pin connector E R S HygroClip HP28 Robust 10 mm diameter tubular probe for measurements in bulk products such as powders and granules. Probe length 280 mm, 2m cable, steel sinter filter. Measurement range: -40…85 °C, 0…100 %RH Accuracy: ±1.5 %RH, ±0.3 K (at 23 ±5 °C) Output: ROV analog and DIO digital signal Order Code: HygroClip HP28 HygroClip HP28-B5 Standard With Binder 5-pin connector HygroClip HS28 Sword Probe For measurements in paper stacks & rolls. Lightweight, yet robust aluminum blade for fast temperature and humidity equilibrium. Sword blade 280 x 18 x 4 mm, Measuring range: Accuracy: Output: -40…85 °C, 0… 100 %RH ±1.5 %RH, ±0.3 K (at 23 ±5 °C) ROV analog and DIO digital signal Order Code: HygroClip HS28 HygroClip HS28-B5 Standard with Binder 5-pin connector Adaptor cable MOK-02-B5 Adaptor cable for probe inputs with Binder 5-pin connector (screw-in type for NT2, NT3 and docking stations) Order code: MOK-02-B5 2 m cable length Calibration devices and humidity standards see page 114/117 26 Accessories for HygroLog-Series Wall Mounting Bracket IPH Wall mounting bracket with integrated power supply connector, suitable for AC1207 adaptor. The use of the external power supply extends battery life of the logger. However, it is not possible to operate the logger with rechargeable batteries. D A T A L O Anti Theft Device The anti theft device may be combined with the wall mounting brackets Hygrolog IPH and IPH-2. HygroLog IPH is fixed on a flat surface together with the securing plate by two screws. A steel rod with a padlock secures the logger in place. (Delivered without padlock) G Order code: HygroLog IPH HygroLog IPH-2 AC1207 AC1005 E HygroLog-SP With connection for power supply Without connection for power supply AC adaptor Anti theft device for HygroLog and HygroLog D, to be combined with HygroLog IPH and IPH-2 Impact protection for HygroLog / HygroLog D G R S Extension Cables and Adaptors For applications in high temperatures or in ducts, etc. where the logger housing may not be directly placed (e.g. high temperatures). Available in 2 lengths: Order code: MOK-01-DAT05 MOK-02-DAT05 1m 2m USB Adaptor for HygroLog The current generation of PCs often do not feature serial ports any more. In such case, the RS232 to USB adaptor may be used for the connection. Set includes: Adaptor cable and CD ROM with driver Order code: 12.02.1086 RS232 to USB Adaptor Adaptor cables for HygroClip industrial probes With these adaptor cables Industrial HygroClip probes may be connected to the HygroLog, HygroLog D and HygroLog NT loggers. Order code: T7-03-DAT05 T7-03-B5 3 m adapter cable for HygroLog D 3 m adapter cable for HygroLog NT Software for HygroLog and HygroLog D Order code: HygroData HL Software and data cable for HygroLog / HygroLog-D 27 HygroLog / HygroLog NT-Series D A T A L O G G E R S Technical Data Feature Humidity/temperature sensor Operating range electronics Humidity Temperature Operating range Alkaline batteries Lithium batteries Measuring range Accuracy at 23 °C Optional output signal Logger Standard output signals via docking station Power supply (recommended) Mains adaptor Battery life with 1 HygroClip probe, 15 min. memory interval no display Display HygroLog NT1 Integrated probe Event logging Menu Adjustment Remote function Docking station Usable probes Sensor protection Housing material Protection rating Memory media Memory capacity with 16 MB Flash Card Log interval Memory modes Alarm indicators Dimensions logger Theft protection Dimensions of docking station Weight-logger Docking station/Wall holder NT-Desk stand System requirements Processor RAM Hard disk capacity Monitor Operating systems Software for programming and analysis Computerized System Validation/Compliance 28 HygroLog NT2 HygroLog NT3 ROTRONIC HygroClip series 0…100 %RH -30...70 °C, with display -10...60 °C HygroLog HygroLog D -30...70 °C -10...50 °C -10...+50 °C (factory assembly) -30...+70 °C probe dependent, from -50…200 °C probe dependent, best ±1.5 %RH none Bluetooth none none RS232, RS485, USB , TCP/IP RS232 RS232 9 V battery ≥500 mAh Possible with docking station 3 x 1.5 V AA -AM3-LR6 With wall mounting bracket > 1 year Approx. 1 year Approx. 1/2 year LCD full graphic display (option) No LCD, alphanumerical All operator actions, alarms, programming Operator guidance, simple programming, retrieval No Possible with probe in logger Display of measurement values on a second HygroLog NT for devices without display Various options, see page 22-23 N/A HygroClip probes Pt100 probes (with docking station) Integrated Wire mesh filter ABS IP65/NEMA4 Flash Card 16 MB included. Possible up to 1 GB 400,000 measurement values in text mode 752,000 measurement values in protected mode Selectable from 5 s to 24 h Start/Stop, text mode, protected mode Optical indicator (LED, red /green), beeper 155 x 106 x 37 mm Integrated in docking station 110 x 70 x 37 mm Approx. 300 g N/A N/A N/A Approx. 175 g -10...+50 °C N/A Wall mounting bracket with supply HygroClip probes EEPROM 10000 values 15 s...120 min Start/Stop or loop mode no Visual indication 140 x 85 x 25 mm Option (184 x 90 x 25 mm) 178 x 90 x 33 mm ca. 200 g HygroLog IPH: 140 g HygroLog IPH-2: 100 g Approx. 350 g (The indicated values are minimal values. The program may be installed and will run. For work with optimal speed, we recommend the use of more powerful PCs. Pentium 2 with processor speed of min. 450 MHz Pentium 90 MHz or better min. 128 MB min. 64 MB Min. 50 MB free Min. 20 MB free VGA or SVGA Windows 98, XP, NT4, with service pack 6a or higher Windows 2000-family with service pack 2 or higher Windows 95/98/2000/NT/XP Windows Server 2003 or higher ROTRONIC HW4 ROTRONIC HW3 Compliant with requirements regarding electronic records and signatures (21 CFR Part 11) Dimensional diagrams and schematics HygroLog NT D A HygroLog / HygroLog D T A 85 L 25 O G 140 G E R S Pin assignment of HygroLog NT and docking stations (all seen from solder side of connectors) Inputs 1, 2 and 3 (HygroLog NT2, NT3) Connector ET-413 Remote connector (HygroLog NT2 / NT3) Connector ET-411 2 3 4 2 1: not used 2: Supply (DC+) 3: GND 4: DIO Signal 5: not used 1 3 1: RX 2: TX 3: GND 5 1 Inputs 4 to 7 (docking stations with HygroClip or analog signal input: DS-U-1, DS-U-2 and DS-U-4) Connector ET-413 Relay outputs (docking station) Connector ET-409 3 2 4 1 1: not used 2: Supply (DC+) 3: GND / Analog signal (-) 4: DIO Signal 5: Analog signal (+) 5 2 3 1 4 1: N.C. contact (Relay de-energized) 2: Common 3: N.O. contact (Relay energized) 4: not used Inputs 4 to 7 (docking stations with Pt100 inputs: DS-PT-2 and DS-PT-4) Connector ET-409 2 1 3 4 1: Supply (DC+) 2: Measurement line (+) 3: Measurement line (-) 4: Supply (DC-) RS-485 connector (docking station) Connector ET-409 2 3 1 4 1 2 1: 485 (-) 2: 485 (+) 3: GND (see notes) 4: DC + (see notes) 4-wire Pt100 3 4 Logical inputs (docking station) Connector ET-409 2 3 1 4 1: + 3.5 VDC 2: Input 1 3: Input 2 4: GND Note: use pins 3 and 4 to apply power to multi-drop RS485 networks with a single 12 VDC power supply with adequate mA rating. Pin 4 and the 12VDC power jack of the docking station are not connected. We recommend the use of electrical junction boxes at each connection point 29 D A T A L Agent-D Series Humidity and temperature logger The Agent-D series is a versatile family of dataloggers with integrated LC display for the measurement of humidity and temperature with both integrated and cable mounted sensors. Measurement ranges and logging interval can be configured with easy-to-use Windows software, or via the integrated keypad. A special version is available for hazardous areas (Zone 1). All versions feature a 64000 point memory, user replaceable batteries and the operating range of the logger is -35…55 °C / 0…100 %RH. Measurement range depends on the probe configuration (see Probes for Agent-D-NT & PT Series). When an extension cable is used, the maximum temperature is 70 °C. Agent-D-HT2 O 2-channel humidity and temperature logger G • Integrated probe for temperature / humidity Agent-D-Clip-S • Optional remote probe for humidity and temperature • Measuring range with: – integrated probe: -35…55 °C / 0…100 %RH – remote probe: -35…70 °C / 0…100 %RH • Single digital input for monitoring doors etc (switch status) G E R Order code: Agent-D-HT2 Agent-D-HT2-EX Agent-D-Clip S Special order: S includes probe Agent-D-Clip-S (for EX-zone 1) includes probe Agent-D-Clip-S Humidity/Temperature probe North American Market Remote cable for Agent-D-HT2 Remote cables for 1 or 2 Agent-D-Clip probes for D-sub connectors Lengths: 2 or 5 m Order code: Agent-D-D12 Agent-D-D22 Agent-D-D15 Agent-D-D25 Special order: 2 m / 1 probe 2 m / 2 probes 5 m / 1 probe 5 m / 2 probes North American Market Agent-D-NT3 3-channel temperature logger for NTC probes • 1 integrated NTC temperature sensor • 2 external NTC probes connected by D-sub-15 plug (Option) • Measuring range: -50…140 °C Order code: Agent-D-NT3 Agent-D-NT3-EX Special order: Universal NTC probe (for EX-Zone 1) North American Market Probes for Agent-D-NT series Universal NTC probe: -50...140 °C, 2 m cable, T max. cable: 140 °C Order code: AC3010-ND1 AC3010-ND2 Special order: 1 probe on D-sub connector 2 probes on D-sub connector North American Market Miniature NTC bead probe Miniature NTC bead probe -50...140 °C, 2 m cable, T max. cable: 140 °C NTC surface probe Order code: AC3055-ND1 AC3055-ND2 Special order: 1 probe on D-sub connector 2 probes on D-sub connector North American Market NTC surface probe -50...140 °C, 2 m cable, T max. cable: 140 °C Order code: AC3041-ND1 Special order: 30 1 probe on D-sub connector North American Market Agent-D-Series Accessories and Technical Data D A Accessories for Agent-D-Series: T Order codes: Agent-D-SW Agent-D-UP Agent-D-IPH Agent-D-IPH-L Agent-D-AL Agent-D-Bat Agent-D-Data Special order: Application software multilingual Software Update Wall mounting bracket Wall mounting bracket lockable Connector with screw terminals Lithium battery for Agent-D Data cable North American Market A L O G Technical data Agent Logger G Features Humidity sensor Temperature sensor Sensor protection Specifications Operating range (electronics) Measurement range Agent-D-HT2 Hygromer® AC-1 NTC Wire mesh filter Agent-D-NT3 None NTC E R S 0...100 %RH / -35...55 °C 0…100 %RH, -50…140 °C; -200…550 °C probe dependent ±1.5 %RH / 0.3K ±0.3 K <0.5 %RH / < 0.1 K < 0.1 K RS232 1 x Lithium 3.6 V battery Up to 2 years (depending on measurement and read-out interval) ABS IP63 IP65 Order code each Agent-D-....EX 64,000 Measurement values / RAM 1 s...180 min Start / Stop or loop Visual indicator on LCD 135 x 85 x 35 mm 110 x 85 x 35 mm approx. 160 g approx. 160 g Accuracy at 23 °C ±5 °C Reproducibility Interface Power supply Battery lifetime Housing material Protection rating EX protection: Zone 1 (optional) Memory size / Memory type Log interval Logging modes Alarm indicators Dimensions weight (with probe inserted) PC-System requirements Processor Operating system Software for programming and analysis Pentium 233 MHz or better, min. 64 MB RAM, VGA or SVGA monitor Windows 95 / 98 / 2000 / NT / XP Agent-D-SW Agent-D-HT2 9 NTC +Ref A B C D GND +Ref DigitIn Alarm + RxD Busy NTC1 NTC2 D1, 2 DigitIn Alarm 0…50VDC, max. 200mA 13 8 34 111.5 Interchangeable probe for humidity and temperature 58 1 15 14 13 12 11 10 9 84 15 GND TxD + Ref. A1 A2 B1 B2 C1, 2 34 8 8 7 6 5 4 3 2 1 F1 F2 F3 GND Agent-D-NT3 1 9 4 3 Res NTC3 11 10 2 1 +Ref NTC1 9 RxD Busy Res. Start/ Inpos Ubat Alarm Reset Alarm NTC 111 .5 34 +Ref UBat 58 15 14 13 12 84 15 GND TxD NTC2 +Ref NTC Sensor integrated in logger housing Start/Inpos Ubat Alarm Reset 34 8 8 7 6 5 31 Introduction T R A N S M I T T E R S ROTRONIC humidity and temperature transmitters are world renowned for their excellent precision, long term stability and reliability. Today our transmitter range offers an unrivalled range of innovative features to complement the core ROTRONIC abilities of measurement accuracy, reliability and long term stability. Transmitters are measuring instruments for fixed installation with an electronic signal output; primarily used for process monitoring and control. In climate control applications, ROTRONIC transmitters are used to optimize energy use and create a comfortable environment. Key features are accuracy, long term stability, simple installation, and easy maintenance; they will easily outperform low cost products typically used in commercial BMS/HVAC systems. Typical applications include building management systems, office buildings, warehouses, clean rooms, hospitals, computer rooms, and telecommunications centers. ROTRONIC industrial transmitters are robust, high quality products designed specifically for demanding commercial and industrial applications. They tolerate exposure to wide temperature variations, condensation and high levels of chemical pollution thanks to the unique properties of the Hygromer® humidity sensor, which ensures excellent long term stability in even the most demanding applications. High precision over a wide operating range (-50…200 °C) is achieved with dynamic temperature compensation The new generation of HygroClip industrial transmitters is based on the latest digital flash technology so probes can be interchanged with no effect on system accuracy. The modular probe concept means on-site calibration and maintenance is virtually eliminated. State of the art features also include calculation of a wide range of humidity parameters such as dewpoint & absolute humidity, user programmable scaling of output signals and networkable digital communications. Typical applications include process monitoring and optimization, test cells, drying processes up to 200 °C, climatic chambers, and high value product environments such as the pharmaceutical and semiconductor industries. Key features Your benefits ● Excellent long term stability <1 %RH per year ➤ Stable measurements and low maintenance ● High accuracy ±1.5 %RH (±1 %RH option) ➤ Precise measurements ● Dynamic temperature compensation ➤ Precision over full operating temperature range ● Chemically resistant humidity sensor ➤ Suitable for harsh industrial applications ● Robust housings ➤ IP65 / NEMA4 protection ● Modular construction ➤ Easy and safe installation ● Wide range of probe configurations ➤ Suitable for any application ● Digital humidity measurement technology ➤ High stability electronics, precision and flexibility ● Interchangeable digital probes ➤ Simple low cost maintenance and minimum down time ● User programmable ➤ Outputs and measurement values can be rescaled ● RS485 networking ➤ Up to 32 instruments can be connected together Section contents HygroFlex Industrial Transmitters ● ● ● ● 32-39 Interchangeable industrial probes Intrinsically safe option 0…100 %RH, -50…200 °C HygroClip Alarm Control module M120 / M130 Light Industrial Transmitters ● ● Duct- and wall-mount types 0...150 °C M-Series/Roline L-Series Transmitters ● ● 54-62 Wide range of options to suit any application 0...100 %RH, -40...100 °C HygroClip S and accessories ● ● ● 32 52-53 HygroClip S probes Ethernet & wireless LAN TCP/IP Interfaces Accessories for HygroClip S 64-71 Transmitter Applications T R A N S M I High Temperature HygroFlex offers the highest direct humidity measurement currently available. T T E Power Stations Power generation, whether nuclear or fossil fuelled, requires carefully controlled environments for best performance and reliability. Intrinsically safe In combination with the HygroClip EX, the HygroFlex can be used to measure humidity and temperature in the most hazardous areas and is ATEX and FM approved. R S Hazardous storage areas Explosive materials such as weapons or chemicals also need to be kept at the correct humidity and temperature conditions. Drying processes Monitoring and control of any industrial drying process can have significant benefits in terms of product quality, energy use and productivity. Ceramics Industry The measurement and control of the drying processes in the ceramics industry. Environmental Test Every product from mobile telephones to a car is today subjected to thorough climatic testing to establish and maintain reliability. Humidity and temperature conditions are a critical part of this process. Paper Industry Monitoring and control of the drying process. 33 HygroFlex T R A N The Digital Advantage HygroFlex is a new generation of industrial humidity and temperature transmitters based on the very latest digital technology. Digital signal processing significantly benefits measurement performance in five key areas: S M I T T 1. Measurement Accuracy: Digital processing of sensor signals provides much more scope and flexibility for the compensation of error components such as linearity and temperature coefficients. ROTRONIC sensors have always been regarded as amongst the most precise and stable in the world; with this new technology, small errors become even smaller! E R S 2. Maintenance and Calibration: Digital signal communication allows components to be ‘hot swapped’ without loss of measurement precision – calibration and sensor data are retained permanently within each digital HygroClip probe. HygroClip probes can be ‘hot swapped’ in seconds, significantly reducing the maintenance and downtime costs associated with the removal of instruments to laboratories or workshops for difficult, time consuming calibration and repair. HygroFlex can also be field calibrated and adjusted directly using the HygroPalm 3 calibrator. 3. Precision and Stability: Digital circuits are inherently more stable than analog, and are less affected by temperature changes. Calibration adjustment is made purely by software, meaning no unstable, hard-to-reach potentiometers. The option for multiple calibration points is extended across the full measurement range. 4. Application Flexibility: Measurement change? Need dew point instead of %RH? Or the mixing ratio? Simply connect the HygroFlex to a PC and change the configuration! New application? If your application needs change, simply fit one of the wide range of probes with an alternative configuration or temperature operating range. Multiple-point measurement? Need to expand? The HW4 software package offers a comprehensive networking solution. HW4 features data logging (reporting), graphical and alarm functions and operates on any standard Windows based PC. The transmitters are compatible with HW4 from instrument firmware version V4.0. Older instruments (from V1.8) may be upgraded if returned to ROTRONIC. 5. Measurement of Dew Point and other Parameters: Digital technology makes it possible to obtain parameters such as dew point or the mixing ratio with economical, versatile and easy-to-maintain instruments and probes. Taking the chilled mirror technology as an example, typical requirements and problems are eliminated: no sampling system is required in most applications, there is no longer any uncertainty between dew and frost, and the requirement for frequent mirror cleaning fully disappears. 34 HygroFlex T R Core features A N S High quality electronics High quality, high stability electronics ensure consistent long term performance. Temperature compensated All ROTRONIC transmitters are dynamically temperature compensated to maintain best possible humidity measurement accuracy over very wide temperature ranges. User calibration All ROTRONIC transmitters can be adjusted by the user to provide optimum precision throughout the product’s life without expensive ‘return to base’ maintenance. M I T T E R S High temperature capability ROTRONIC transmitters have the widest direct humidity measurement range in the world working from -50…200 °C. Digital technology Digital signal processing not only provides the best possible precision, but also allows fully digital adjustment for all industrial HygroClip probes. High quality sensor The Hygromer® IN-1 humidity sensor is arguably the best in the world. Precise factory adjustment and superb long term stability provide consistent measurement results with minimum maintenance. Interchangeable probes. Across the entire ROTRONIC transmitter range it is possible to specify interchangeable probes; simplifying field maintenance and maximising application flexibility. Probe simulators are available for system validation purposes. These provide a fixed value for humidity and temperature. Because the accuracy of the digital signal is absolute, the whole measurement loop can be validated and adjusted. 35 HygroFlex 1 T R A N S Industrial transmitter with 2 analog outputs HygroFlex 1 accepts one HygroClip probe and provides two linear analog outputs for relative humidity and temperature. Standard factory configuration is 4...20 mA, but this can be easily changed to 0...20 mA, 0...1 V, 0...5 V or 10 V. Scaling of the output range can be modified from the standard 0...100 %RH and 0...100 °C using the internal service connection, connecting cable AC1623 and a PC running the HW3/ HW4 software. For system validation purposes, you may want to use our probe simulators. See page 118. M Key features: I • 1 probe input for interchangeable HygroClip Industrial probes • Combined measurement of humidity and temperature. • Probe input suitable for analog ROTRONIC probes (0...2.5 V, 10 Bit A/D interpolated: 12 Bit) • 2 linear, scaleable analog outputs • Configuration of output signals by jumpers • Remote connector for HygroPalm reference instrument • Operating ranges: electronics 0...100 %RH / -40...60 °C, with display -30...60 °C • M16 cable gland • Optional display/keypad for monitoring /adjustment T T E R S Dimensional diagrams (for all HygroFlex types, except metal housing Probe calibration HygroFlex 1 Ordering Information For ordering information within North America please contact us at: Rotronic Instrument Corp. 160 E. Main Street Huntington, NY 11743 800-628-7101 Visit our website at: www.rotronic-usa.com Suitable probes see pages 40 to 43. HygroFlex 1 Standard Connection Layout M16 cable glands for power and signal cables Probe (Tuchel) Test socket (Binder 712, 2-pin) 36 HygroFlex 2 T R Digital transmitter for monitoring applications HygroFlex 2 measures and transmits humidity and temperature measurements only in a digital format. Up to 32 transmitters can be networked in master/slave mode via RS232/RS485. The master transmits the data via RS232 signal to a PC, while the slaves communicate via RS485 with the master. HygroFlex 2 transmitters may be networked in combination with HygroLog NT data loggers. If control functions must be performed in addition to monitoring, the network can be used with a HygroClip Alarm module. HygroClip Alarm monitors the network according to user defined values or limits and can perform alarming and control functions with 4 relays. Details see pages 46...47. HygroFlex 2 transmitters may have 2 probes connected. So it is possible to set up a network with up to 64 probes and therefore 128 measuring values at a very reasonable price. Probe cables up to 10 m and optional probe extension cables up to 200 m length cover all applications and installations. An external test socket is standard. The HygroFlex 2 may be fully configured by the user. Psychrometric calculations for parameters such as dew point or mixing ratio are also available. A N S M I T T Key features: E • Combined measurement of humidity and temperature. • Optional 2nd probe input (Tuchel), suitable for analog probes (e.g. pressure probe) (0...2.5 V, 10 Bit A/D interpolated: 12 Bit) • Digital output signal for monitoring (RS232 / RS485) • Psychrometric calculation such as dew point, mixing ratio etc. (with display/keypad option) • Networkable (RS485) • Remote connector for HygroPalm reference instrument • M16 cable gland • Fully user programmable • Operating ranges: electronics 0...100 %RH / -40...60 °C, with display -30...60 °C • Optional display/keypad for monitoring /adjustment R S Option: Metal housing USB/RS232 TCP/IP RS485 HygroFlex 2 Ordering Information For ordering information within North America please contact us at: Rotronic Instrument Corp. 160 E. Main Street Huntington, NY 11743 800-628-7101 Visit our website at: www.rotronic-usa.com Suitable probes see pages 40 to 43. HygroFlex 2 Standard Connection Layout Test socket (Binder 712, 2-pin) Probe 1 (Tuchel) Serial connection RS232/485 (Binder 763/5-pin) Optional Probe 2 (Tuchel) Power connection (M16 cable gland) 37 HygroFlex 3 T R A N S M I T Process Control, Monitoring and Absolute Humidity Calculation HygroFlex 3 combines all the features of the HygroFlex 1 and 2 into a highly specified instrument, and represents probably the most advanced humidity and temperature transmitter available today. Additional features include a third analog output for greater flexibility, a simultaneous serial output and the ability to dynamically compensate calculated humidity parameters for variations in application pressure. HygroFlex 3 is particularly well suited to combined monitoring and control applications. The analog outputs can be connected to the application’s control system, while the digital network data signal interfaces with a local PC where engineers can monitor the process and set up alarms via Email or SMS text messages. With the dynamic pressure compensation feature, humidity measurement can be optimized whenever pressure dependent values such as enthalpy and wet bulb temperature are to be calculated. T E Key features: R • Combined measurement of humidity and temperature. • Probe input for digital or analog ROTRONIC probes • Optional 2nd probe input (Binder), suitable for analog probes (e.g. pressure probe) (0...2.5 V, 10 Bit A/D interpolated: 12 Bit) • 3 linear, scaleable analog outputs: humidity, temperature and calculated value (e.g. dew point, mixing ratio etc.) • Digital signal for networking / monitoring (RS232 / RS485) • Fully user programmable • Operating range electronics 0...100 %RH / -40...60 °C, with display -30...60 °C • Configuration of output signals by jumpers • Remote connector for HygroPalm reference instrument • Optional display/keypad for monitoring / adjustment • 2 M16 cable glands S USB/RS232 TCP/IP RS485 HygroFlex 3 Ordering Information For ordering information within North America please contact us at: Rotronic Instrument Corp. 160 E. Main Street Huntington, NY 11743 800-628-7101 Visit our website at: www.rotronic-usa.com Suitable probes see pages 40 to 43. HygroFlex 3 Standard Connection Layout Power & analog output connection (M16 cable glands) Probe 1 (Tuchel) Test socket (Binder 712, 2 pin) 38 Probe 2 (Option) Binder 712, 5 Pin Serial connection RS232/485 (Binder 763/ 5-pol) HygroFlex Technical Data T R HygroFlex technical data A Specifications Inputs Probe connections (combined %RH / °C) Signal input Third party probe input (1 analog) Outputs Analog outputs Output signal allocation: configured at factory (jumper selectable) Type of output: (jumper selectable) RS232 interface RS485 networkable (up to 32 devices) Input/output scaling range Adjustment of probes 1 point %RH, °C/°F 4 points %RH, 2 points °C/°F 4 points %RH, 2 points °C/°F, via PC Test connector for communication with HygroPalm handheld Calculation & Unit Display Calculated humidity values display and output Pressure compensation for calculated values Technical Data (included probes) Measuring range (including probes) Accuracy at 23 °C Reproducibility Sensors Electronic operating range Display/Keypad (Option) Display resolution (Option) Housing/dimensions IP protection rating Weight Supply voltage Electrical connections Connection terminals Analog output configured at factory HygroFlex 1 HygroFlex 2 HygroFlex 3 1 2 2 (1 is an option) Digital or analog: 0…2,5 V, 0…20mA, 10 Bit A/D, 15 V DC, max. 10 mA supply available No Yes, Input impedance > 1 MΩ 2 scaleable Output 1= humidity Output 2 = temperature No N/A 0…1 V, 0…5 V, 0…10 V, 0…20 mA or 4…20 mA No No -999…9999 None 3 scaleable Output 1= humidity Output 2 = temperature Output 3 = calc. parameter 0…1 V, 0…5 V, 0…10 V, 0…20 mA or 4…20 mA Yes Yes S M I T T E R S Yes, with display/keypad option Yes, with display/keypad option No Yes Yes No Full range of calculated values including Dew point, wet bulb, enthalpy, mixing ratio, water vapor pressure, saturation vapor pressure. User defined scale No Manual or automatic with optional pressure probe CE Conformity Probe dependent, 0…100 %RH, -50…200 °C, 0…2000 hPa Probe dependent, see HygroFlex probes Probe dependent, see HygroFlex probes Probe dependent, see HygroFlex probes 0…100 %RH (non condensing), -40…60 °C, with display -30…60 °C Liquid Crystal 3 line numeric, membrane keypad 0.1 %RH, 0.1 °C, 0.01 calculated value ABS, 207 x 150 x 58,3 mm, Metal housing optional IP65 / NEMA4 310 g Standard 12…35 VDC (140 mA), 12…24 V AC, optional: 90…250 VAC, 3.5 VA M16 cable gland (7 mm cable) 18 AWG Current output (0/4…20 mA), max. load 500 Ω, others are jumper selectable Voltage (0…1, 5, 10 V), min. load 1000Ω. Automatic load compensation Complies to standards: EN61000-6-2:2001, EN61000-6-4:2001 Schematics: Voltage outputs Current outputs K1-1 K1-2 K1-3 N VDC – (HTS11, 21, 31) or VAC neutral (HTS12,22,32) VDC + (HTS11, 21, 31) or VAC Phase (HTS12,22,32) Protective ground K2-1 K2-2 K2-3 K2-4 Relative humidity (+) Temperature (+) Calculated parameter (+) Signal ground (-) 39 T R A N S M I T T E R Industrial Probes for HygroFlex A fully interchangeable range of probes, each with integral calibration, simply choose the best option to suit your application. If your application needs change, choose a different probe! HygroClip IW For wall mounting applications (area monitoring), lightweight construction for fast thermal response. Measurement range: 0…100 %RH, -40…85 °C Accuracy: Standard: ±1 %RH / ±0.3 K (at 23 ±5 °C) Output: ROV analog and DIO digital signal Probe: Sensor protection: Order code: HygroClip IW S Delrin 25/15 mmØ Wire mesh filter (replaceable) Standard probe with factory certificate of conformance N.I.S.T. traceable Certificate of Calibration available upon request HygroClip IC Cable mounted probe for flexible installation in varied applications such as high temperatures, climatic chambers, ducts etc. Two versions are available, 120 & 250 mm probe length. Measurement range: Accuracy: Probe: Cable: Sensor Protection: 0…100 %RH, -50…200 °C ±1 %RH / ±0.3 K (at 23 ±5 °C) PPS 15 mmØ 2 m / 5 m / 10 m Metal slotted cap, wire mesh Order code: HygroClip IC-1 HygroClip IC-1-5 HygroClip IC-1-10 HygroClip IC-3 HygroClip IC-3-5 HygroClip IC-3-10 120 mm probe, cable length 2 m 120 mm probe, cable length 5 m 120 mm probe, cable length 10 m 250 mm probe, cable length 2 m 250 mm probe, cable length 5 m 250 mm probe, cable length 10 m HygroClip IM Robust stainless steel probe for duct, or through-wall installation. Suitable for use in the food industry. Two versions are available, 120 & 270 mm probe length. 40 Measurement range: Accuracy: Probe: Cable: Sensor Protection: 0…100 %RH, -50…200 °C ±1 %RH / ±0.3 K (at 23 ±5 °C) Stainless steel, V2A / 1.4305, 15 mmØ 2 m / 5 m / 10 m available on request Metal slotted cap, wire mesh Order code: HygroClip IM-1 HygroClip IM-1-5 HygroClip IM-1-10 HygroClip IM-3 HygroClip IM-3-5 HygroClip IM-3-10 120 mm probe, cable length 2 m 120 mm probe, cable length 5 m 120 mm probe, cable length 10 m 270 mm probe, cable length 2 m 270 mm probe, cable length 5 m 270 mm probe, cable length 10 m Industrial Probes for HygroFlex R HygroClip IE Screw-in probe for pressure or vacuum applications between 0.002 and 100 bar and temperatures of -50 to 200 °C. Two versions are available with different threads 1⁄2” G or 1⁄2” NPT. Measurement range: Accuracy: Probe Probe body: Housing: Cable length: Sensor protection: Order code: HygroClip IE-1 HygroClip IE-1-M HygroClip IE-3 HygroClip IE-3-M T 0…100 %RH, -50…200 °C (depends on version) ±1 %RH / ±0.3 K (at 23 ±5 °C) Stainless steel AISI 303 POM plastic for use up to 85 °C, stainless steel up to 200 °C 2m Metal slotted cap, sintered steel filter A N S M I T T /2” G fitting pressure probe, POM body, max. 85 °C 1 /2” G fitting pressure probe, stainless steel body (max. 200 °C) 1 /2” NPT pressure probe, POM body (max. 85 °C) 1 /2” NPT pressure probe, stainless steel body (max. 200 °C) 1 E R S HygroClip IC04 / 05 4 or 5 mm diameter probes for measurement in tight spaces such as climatic test applications, or monitoring conditions of materials such as brick, concrete or timber. Measurement range: Accuracy: Probe: Recommended application range: %RH Order code: HygroClip IC04 HygroClip IC05 0…100 %RH, -40…100 °C ±1.5 %RH / ±0.3 K (at 23 ±5 °C) Nickel plated brass -40...40 °C: 0...99 %RH / 40...100 °C: 0...70 probe Ø 4 mm, cable length 2 m probe Ø 5 mm, cable length 2 m HygroClip ICx with 15/25 mm Probe HygroClip industrial probe with maximum probe diameter of 25 mm to replace old transmitter series such as the I-1000, I-200 and I-2000 without the need to change pre-existing mounting hardware. Specifications are the same as for the standard HygroClip IC probes. The order codes are the same as for the standard probes, but with the extension HygroClip IC-x-15-25, where x defines the probe length. The robust mechanical construction allows probe lengths up to 700 mm. Example: HygroClip IC-3-15-25 (probe length = 250mm) Sensor Protection: Metal slotted cap, wire mesh Special Order: North American Market Order code: HygroClip IC-……15 /25 Probe lengths available (…): 250mm (3), 400mm (4), 500 (5) and 700mm (7) Probe simulators with fixed output values for system validation are available; values may be defined by the user. See page 118. 41 BFC Plate Probe for On-Line ERH Measurements T R The BFC plate probe is specifically designed for the measurement of Equilibrium Relative Humidity (ERH) on moving webs such as paper, card and textiles. It measures the ERH by direct contact with the moving web up to certain speeds. If the web speed is high or the surface is not smooth, measurement can still be performed by separating the BFC from the web by 0.5 to 1mm to reduce friction, create an ‘air-cushion’ and therefore minimize any temperature errors. A N S The BFC is used in combination with the HygroFlex range of transmitters, and is based on the same digital measurement technology as the standard HygroClip Industrial probes. Cable length can be up to 200m when using the active extension cables detailed on page 39. Depending on the HygroFlex version selected, two probes can be connected simultaneously, and up to 32 HygroFlex connected together on an RS485 network to allow multiple web positions. M I T T E R S Features: Benefit: ● On-Line ERH measurement ➤ Allows on-line monitoring and control of manufacturing process ● Continuous operation ➤ Minimizes need for further quality control measurements ● Temperature compensated ➤ Precise measurement when temperature varies ● Combined %RH/°C measurement ➤ Both key parameters measured simultaneously ● Compatible data logging software ➤ Independent data for process analysis and reporting ● Software alarm function ➤ Email/SMS notification of control problems Technical data BFC probe Humidity Measurement Range Temperature Measurement Range Accuracy at 23°C Repeatability Response time Long Term Stability Sensors Digital Adjustment Points Electronics operating range Output signal Power Conformity Order codes: BFC-DIO-T7 EBFC ET-W24-Set Special Order: 0…100 %RH/ERH 0…50 °C ±1.5 %RH, 0.3 °C <0.5 %RH, 0.1 °C %RH < 15 s if probe and web are at the same temperature < 1 %RH, 0.1 °C per year %RH Hygromer IN1, °C Pt100 1/3 DIN 35, 80, 10, & 0 %RH, Single point user defined, T0 & Tmax 0…50 °C DIO Digital to HygroFlex, HygroFlex can provide 4…20 mA, 0…10 V, RS232/RS485 VDC (provided by HygroFlex) EN61000-6-2:2001, EN61000-6-4:2001 Plate probe with 1 m cable, terminated in 7-pin Tuchel plug to suit HygroFlex probe input 1. For extension cables see page 45 Calibration device for BFC (see page 103 for calibration standards) Replacement filter for BFC North American Market HygroFlex transmitter Installed and maintained correctly, the BFC will provide many years of accurate service for a fraction of the cost of on-line moisture measurement equipment. Maintenance is limited to occasional replacement of the sensor protection filter, and periodic checks of calibration. Output analog Plate probe BFC-DIO 42 Plate probe BFC-DIO The performance of paper is highly dependent on the final ERH value. Issues such as curl, tight edges, dust, print mis-register and feed problems can be virtually eliminated if ERH and the associated ambient %RH conditions are considered and maintained. The BFC, HygroFlex and complementary products such as ambient measurement probes, handheld sword hygrometers, data loggers and software, can be integrated together to provide the measurements needed to optimize the production of web based sheet material production. The equipment is supplied pre-calibrated and ready to use. All that is required is for the plate to be installed mechanically onto the customer’s machinery, using either the in-house or the equipment manufacturer’s engineer. HygroClip EX T R HygroClip EX probes are based on the digital ROTRONIC HygroClip technology and may be used in hazardous areas. They can be used as analog 2-wire 4...20 mA devices for humidity or temperature and in combination with a HygroFlex transmitter - also as digital instruments for both parameters. Each probe is made of high grade stainless steel. In order to fulfill the regulations for hazardous zones, a Zener barrier or galvanic separation must be installed between the probe and the HygroFlex transmitter or the respective control unit. N Applications S ATEX 2180 Zone 0/20 Zone 1/21 T5 T6 Class ll, Division1 Group E,F,G Zone 1/21 T6 Class l, Division1 Group A, B, C, D Safe zone Zener barrier or galvanic separation A M HygroClip IC-EX I HygroClip IC-1-EX ll 1 G EEx ia llC T5 resp. ll 2 G EEx ia lC T6 II 1/2 D IP6X T 80°C HygroClip IE-1-EX T T E R HygroClip IE-1-EX ll 1 G EEx ia llC T5 resp. ll 2 G EEx ia lC T II 1/2 D IP6X T 80°C S HygroClip ID-EX In zone 21, only the sinter filter must be used. In zone 21, only the sinter filter must be used. HygroClip ID-1-EX ll 1 G EEx ia llC T5 resp. ll 2 G EEx ia lC T II 1/2 D IP6X T 80°C HygroClip IW-1-EX HygroClip IW-1-EX ll 1 G EEx ia llC T5 resp. ll 2 G EEx ia lC T6 II 2D IP6X T 80 °C Order code: HygroClip IC1-EX HygroClip IC3-EX HygroClip IE-1-EX HygroClip IE-3-EX HygroClip ID-EX HygroClip IW-EX Cable probe with 120 mm probe length, 2 m cable Cable probe with 270 mm probe length, 2 m cable Screw-in probe with G 1⁄2 “ thread Screw-in probe with NPT 1⁄2 “ thread Duct probe with 250 mm probe length Wall mount probe with 150 mm probe length xx ET-7018 Blue cable between HygroClip and Zener barrier, Ø= 5.2 mm xx = cable length. Note: The cable color MUST be blue. Mounting flange for HygroClip IC-EX Zener barrier Z722 for use with HygroFlex (DIO signal) Zener barrier Z788H, for 2- wire 4...20 mA applications without HygroFlex Zener barrier Z722 with housing (space for 4 Z722) Zener barrier Z788H with housing (space for 4 ZB788H) Housing for 4 Zener barriers Z722 or Z788H) Cable between Zener barrier and HygroFlex, with converter. xxx= length m (must be used in combination with HygroFlex). Wire mesh filter element, for high humidity, minimal measuring delay Sinter filter element, stainless steel Teflon filter for best filtration, not for high humidity applications Service / calibration cable Calibration device for all HygroClip Ex probes Pack of 5 SCS certified humidity standards xx = 00, 05, 10, 11, 20, 35, 50, 65, 75, 80, 95 %RH AC1301-MEX ZB1 ZB1-420 ZB2 ZB2-420 ZB housing AC1617-ZBxxx SP-M15 SP-S15 SP-T15 SPB5-WIN ER-15 EAxx Notes: The total cable length between HygroClip-EX probe and HygroFlex transmitter must not exceed 200 m. HygroClip EX probes MUST NOT be calibrated in the hazardous zones! 43 T R H yg ro Clip EX Technical Specifications and Ordering Information s HygroClip EX Technical Specifications A N S M I T T E R S Specifications Humidity measuring range: Operating range: Best accuracy at 23 °C: Repeatability: Response time: Long term stability: Sensors: Adjustment points: Electronics operating range: Output signals: Load max: Power: Enclosure: Probe dimensions / cable length: 2 m cable Electrical connections: Inspection certificate: PTB Marking: FM approval: FM marking HygroClip ID-EX HygroClip IW-EX HygroClip IC-EX HygroClip IE-x-Ex 0...100 %RH Electronics: -40...40 °C; at probe: temperature of medium, max. -50...200 °C ±1 %RH, ±0.2 K < 0.3 %RH, 0.1 °C <15 s at 1 m/s air velocity at 23 °C < 1 %RH, 0.1°C per year Humidity - Hygromer® IN-1; Temperature -Pt100 1/3 DIN Digital; 1...4 point %RH, 2 point °C -40...40 °C, 0...100 %RH DIO digital, analog 4...20 mA Max. 800 Ω at 26 VDC Max. 26 VDC, 4...20 mA in loop power configuration High grade stainless steel 316, DIN1.4401, 150 x 100 x 58 mm / IP65 / NEMA4 250 x 15 mm Ø 150 x 15 mm Ø IC1: 120 x 15 mm Ø, 142 x 25 mm x 1/2” other lengths possible IC3: 270 x 15 mm Ø, 27 mm wrench size Cable glands/terminal block PTB01 ATEX 2180 ll 1 G EEx ia llC T5 resp. ll 2 G EEx ia lC T6 II 1/2 D IP6X T 80 °C) II 2 D IP6X T 80 °C II 1/2 D IP6X T 80 °C) FM 3015571 IS / I, II, III / 1 / ABCDEFG / T6 – 12.0724.0006 IP66 Application with HygroFlex transmitter Safe zone 4...20 mA application without HygroFlex Safe zone Ex zone Ex zone XXET-7018 Zener Barrier XXET-7018 RS232/RS485 4…20 mA HygroClip ID / IW / IC-EX Zener Barrier Dimensional diagrams Duct-mount probe 44 Wall-mount probe Cable type Screw-in probe Accessories T R HygroFlex Probe Extension Cable A Should you wish to extend the distance between the HygroFlex transmitter and probe, the extension cable AC1616 can be specified with lengths up to 200 m thanks to an integral signal booster. Order code: AC1616 N S Where required length = 2 to 200 m (Specify length separately) M I T T E R Probe options and filters S Function: Protects sensors against pollution and high air velocity (up to 40m/s). A filter is required for air velocity above 3 m/s. Order code BS15 Type of filter Steel sinter filter element pore size approx. 5 µ Material: DIN1.4401 (V4A) Properties High level of filtration Marginal effect on response times. Not suitable for high humidity applications V max. 40 m/s BG15 Wire mesh filter element mesh size approx. 20-25 µ Material: DIN1.4401 (V4A) 20 m/s BF15 Teflon filter element pore size approx. 10 µ SP-MSB15 Metal slotted sleeve, serves as filter carrier Material: Nickel plated brass Minimal measuring delay Reduced filtration efficiency for small particles. Suitable for high humidity applications Good filtration effect Extends response time in low air velocity. Water repellent but water vapor permeable Protects against mechanical damage when filter is removed No filter effect ET-W24-Set Wire mesh filter mesh size approx. 20-25 µ Material: DIN1.4401 (V4A) Minimal measuring delay Reduced filtration efficiency for small particles. Suitable for high humidity applications 20 m/s 3 m/s 20 m/s Mounting accessories for 15 and 25 mm diameter probes. When the electronics housing is mounted directly onto a wall or duct, no accessories are required. When the probe is mounted on a duct, an AGRO screw fitting and flange are to be used (duct and cable types). The flange is only required if the AGRO screw fitting cannot be fixed alone; e.g. in small ducts with no access. Order code Sealing Probe Ø T max. AG H (mm) Flange QMA-15 Viton 15 mm 200 °C M 20 x 1.5 26 AC1305 QMA-25 Viton 25 mm 200 °C M 32 x 1.5 31.5 AC1306 ½" G thread on request 45 HygroClip Alarm T R A N S M I HygroClip Alarm is a universal programmable alarm and control system that can be interfaced with the HygroLog NT, HygroFlex, HygroLab and M-Series instruments on an RS485 network, or operated independently from measurement equipment and PCs. It can alarm or control in a variety of ways, including with a fully customizable logic diagram. With four relays, it is possible to control four single alarm conditions or a block of up to 128 AND / OR linked alarms. The configuration of the relays and the related logic array is performed with the Rotronic HW3 software to precisely meet the requirements of the user. The relays can be directly used for switching loads up to 2500W. 2 digital inputs are also available to provide switch inputs, for example, to indicate when a door is opened. Also included is a timer function which could for example be used to control a ventilation system at night time, control opening and closing of the windows of a greenhouse, or switch lights depending on the time periods set etc. The possible applications are extensive. T T E R Features S • 4 alarm relays assigned to independent values • 1 alarm computed from up to 128 measured values (AND / OR linked) • Dew point calculation from humidity/temperature values • 2 digital inputs • 4 relay outputs (with status LEDs) • Real time clock with battery backup • Freely configurable internal logic, consisting of: - 12 Signal delays - 6 Flipflops - 12 Gates (AND / OR / XOR) - 2 Monoflops - 1 Pulse width modulator - 2 Alarm times from the real time clock - 4 virtual keys (controlled by PC software) - Event protocol generation by HW3 Software Order code: HygroClip Alarm1 HygroClip Alarm2 HW3 with power supply 12...35 VDC/12...24 VAC with power supply 90...250 VAC software Functions 1. Checking measured values: The measurement data from a HygroFlex, HygroLab or M-Series transmitter are interrogated via the RS485 network. If a preset alarm condition is detected, the device sets an alarm by switching on one or more relays according to the programming of the HygroClip Alarm. Any of the parameters measured by the instruments mentioned above can be monitored (humidity, temperature, pressure, air flow etc.) 2. Independent control unit. HygroClip Alarm may be used as an independent control unit, and as such, switch various devices. For example, switching on a ventilation unit for 10 minutes every hour. In this mode, HygroClip Alarm is completely independent of any PC or other device. 3. Remote control. Using HW3 software, virtual keys can be operated. This may be useful to cancel an alarm or switch a relay remotely. Example: Monitoring of a cold store The temperature of a cold store as well as the status of the door - door open or closed - is monitored. Controlled by a relay, a siren or flashing light is switched on if the temperature is too high or the door is open for an extended period of time. Operating modes Basic Mode In the basic mode, HygroClip Alarm is configured using the HW3 software, where the user interface allows a maximum of 4 parameters and 2 external signals (switches) to be directly assigned to the relays. An example might be where the humidity value exceeds a user defined set-point, and hence the relay activates to switch on a fan or dehumidifier. Programmable Logic Mode In this mode, the alarm functions are displayed graphically, and are programmed by dragging and dropping various logic symbols onto a logic diagram. Programming is performed directly within the HW3 software and is arranged in a very user-friendly way. With more complex functions such as AND / OR / NAND, more intelligent alarming or control functions can be configured. An example might be where a dehumidifier will run only when the humidity value is greater than set-point, and access doors are closed. Data logging Data logging is performed by the HW3 software. All alarm events are logged together with the measured values, even if the PC is switched off (e.g. due to power failure or at night time). HygroClip Alarm logs up to 20 events, these may be evaluated afterwards from a PC. Cancelling an alarm or activating a digital input is considered to be an event. 46 HygroClip Alarm T R Application example of networked transmitters and HygroClip Alarm A N S M I T T Supply E R RS485 S USB/RS232 TCP/IP Relay outputs Configuration of HygroClip Alarm Configuration of HygroClip Alarm is performed by a logic diagram in a simple and user friendly way. The diagram may be saved as a configuration file. This makes it very easy to adapt HygroClip Alarm to changing conditions: you may want to run different programs during the week and at weekends, or in summer or winter time. Technical Data HygroClip Alarm Power supply Power consumption Inputs Outputs Clock Interface Housing material Dimensions Electrical connections Protection class 12...35 VDC / 12...24 VAC (HygroClip Alarm 1) Or 90...250 VAC (HygroClip Alarm 2) 50 mA (without relays) 2 digital inputs 0...5 V or switches 4 Relays (10 A @ 250 VAC/30 VDC, 12 A @ 125 VAC) Real-time clock RS485 interface Makrolon 160 x120 x 75 mm 3x M12, 5x M16 Cable glands IP65 47 Dew point probes RODP60 and RODP10 0 T R A N S Measurement of relative humidity using Rotronic capacitive Hygromer® sensors allows software based calculation of the dew or frost (Dp/Fp) point temperature. However, below -30°C Dp/Fp specific sensors are recommended. ROTRONIC offers dew/frost point sensors that are compatible with the HygroFlex transmitter range, and that can also be used as autonomous 2-wire loop powered transmitters. The sensors used in these products are aluminium oxide based, and are pre-calibrated over the specific measurement ranges. M I T RODP60 / RODP 100 T Features: E • • • • • • • R S Dew point measurement to -100 °C (Dp/Fp) 2-wire loop powered HART digital output signal Aluminum oxide sensor High grade stainless steel enclosure Measurements in pressurized or atmospheric environments Various connection threads are available Order code: RODP60 RODP100 Special Order: -60...30 °C (Dp/Fp) -100...20 °C (Dp/Fp) North American Market Technical Data Specifications Sensor Voltage supply Dew point range Operating range (sensor) Operating range (transmitter) Accuracy Repeatability Resolution (input) Output signals Electrical connection Threading Enclosure Dimensions and weight Approvals (pending) FM NEMKO RODP60 Aluminum oxide sensor 5...28 VDC, 4...20 mA 2-wire loop powered -60...30 °C (Dp/Fp) -10...70 °C -30...85 °C ±2 °C (Dp/Fp) ±0.2 °C 0.1 °C (Dp/Fp) 4...20 mA or digital HART protocol selectable 4-pin standard industrial connector, 9.4 mm, IP65 / NEMA4 M14 x 1.25 and 3⁄4”-16 UNF-2A, others on request High grade stainless steel enclosure ~32 x 136 mm, 230 g IS Classl,ll,lll, Division 1, Groups A,B,C,D,E,F,G T6 at 40 °C ambient T4 at 85 °C ambient Class1 Zone 0, AEx ia llC T6 (-20 ≤ Ta ≤ 40 °C);T4 (-20≤ Ta ≤ 85 °C) NI Class 1, Division 2, Groups A,B,C & D; Suitable for Class ll, Division 2, Groups E,F & G and Class lll, Division 2 Ll1 GD ATEX EEx ia llC T6 EEx nA llC T6 Please contact ROTRONIC when you need an EX-rated probe. .750-16UNF-2A thread M14 x 1.25 thread 48 RODP100 -100...20 °C (Dp/Fp) Hi-Accuracy Industrial HygroStat MB HygroStat MB is the new HygroClip-compatible Hygro-Thermostat for the direct control of two 230 V relays with change-over contacts. The device is microprocessor controlled and may be used with all ROTRONIC Industrial probes (see pages 40 to 41). With an adaptor cable T7-03-MOK-DIO, HygroClip S probes may also be connected. The HygroStat MB requires no maintenance. Calibrating and adjusting or replacement of the probe is sufficient. Due to the digital signal processing, there is no loss of accuracy. HygroStat MB allows direct control of simple tasks such as the switching of dryers or humidifiers etc. Additionally, HygroStat IM features a timer, which allows operation of the Hygrostat only at specified times, such as work days etc. T R A N S M I HygroStat MB T Main Features • • • • • • • • • 2 relays with change-over contacts for mains voltage Control of humidity and temperature values Networkable Indication of relay status by 2 LEDs Programmable by HW4 software USB programming interface RS232/485 / Ethernet / wireless LAN TCP/IP interfaces optional High accuracy ±1 %RH / ±0.2K (at 23 °C ±5°C) Programmable hysteresis T E R S Order codes: For ordering information within North America please contact us at: Rotronic Instrument Corp. 160 E. Main Street Huntington, NY 11743 800-628-7101 Visit our website at: www.rotronic-usa.com Technical Data Probe connections Operating range electronics Measurement range Hysteresis Display Number of relays with LED status indicator Real time clock functions Psychrometric calculations Programming by HW4 software / PC Engineering units Programming interface Communication interfaces (Option) Networkable with Adjustment Power supply / power consumption IP-protection rating / fire resistance Approvals 1 socket for interchangeable HygroClip Industrial probes (see pages 40...41) 0...100 %RH / -40....+ 85 °C (with display) -10... + 60 °C (without display) Probe dependent (max. 0...100 %RH / -50...200 °C) Freely programmable LC display optional 2 x 250 VAC/ 2 A rated, with change-over contacts Yes All standard calculations available Set-points, hysteresis, signal assignment, calculated values, relay functions Metric or English USB on pcb (access only with enclosure opened) RS232/485 or Ethernet / wireless LAN TCP/IP HygroFlex, HygroLog NT with docking station Single- and multi-point adjustments with HW4 software / PC 12...35 VDC / 12...24 VAC (IM-1x) or 90...230 VAC (IM-2x) / <300mA IP65, UL94-HB compliant (with TCP/IP interface: IP54) EN 61000-6-3 + EN 61000-6-1 EN 61000-6-4 + EN 61000-6-2 Schematic 49 M 10 0 – Light Industrial, M-Series and Roline L-Series Transmitte r s T R A N S M I T T E The measurement and control of humidity in light industrial applications is becoming more demanding and widespread. Occupant comfort and energy saving benefits are recognized by today’s commercial and industrial markets. Heating, air conditioning and ventilation are increasingly sophisticated; cooled ceilings provide an agreeable atmosphere, hardly any air movement may be felt, controlled humidity maintains comfortable conditions and minimizes energy use. Air changes in buildings are reduced to an absolute minimum in order to save energy, so temperature and humidity values are controlled within ever smaller margins. The accuracy of measurement instruments must meet these increasing demands, and ROTRONIC has developed a completely new range of instruments to suit. The M100 light industrial series replace the I-1000 transmitters and are fully compatible. The HVAC transmitters of the M-Series represent the latest development in digital humidity measurement. Their excellent capabilities of high precision and long-term stability are well known. By making best use of digital technology, they also offer a range of useful and convenient features to further improve measurement performance and handling. For example, it is now possible to rescale the measurement output range to suit the control application (e.g. 40...60 %RH = 4...20 mA) improving resolution, and ultimately control. The L-Series represents a new direction for Rotronic into the lower cost HVAC market segment. Our design engineers have developed a product that combines ROTRONIC’s core values of long-term stability, precision and fast response, but which at the same time is extremely cost effective. R S Key features Your benefits ● Compact, modern instruments ➤ Easy to handle and flexible ● Optional display ➤ Easy observation of measured values ● Accuracy and long term stability ➤ Reliable data and reduced maintenance ● Interchangeable sensor module ➤ Easy calibration and maintenance ● Scaleable output signals ➤ Better resolution, more precise control ● All standard signals available ➤ One instrument for all types of control systems ● Aesthetic housing ➤ Suitable to office environments ● Psychrometric calculations ➤ Dew point, wet bulb, enthalpy etc. measurement This sub-section contains M100 Light Industrial Transmitters ● ● ● ● ● M-Series ● ● ● ● ● ● 54-59 Interchangeable probes Optional display Scaleable output signals Psychrometric calculations High accuracy Remote adjustment with handheld Roline L Series ● ● ● ● ● 50 52-53 Integrated probes Duct- and cable-mount probes Scaleable output signals Digital signal processing and adjustment High accuracy Best price / performance ratio Fixed probe 2x2 wire technology Humidity or temperature only versions Remote adjustment with handheld 60-62 Applications T R A N S Storage rooms M I T Libraries T E R Cold stores S Green houses Computer/Server rooms Museums Climate control in office buildings Snow guns Railway stations 51 M10 0-Series Light Industrial Transmitters T R A N S The M100 Series has been developed to meet the needs of the light industrial market. Their high specification, compact design and extensive range of configurations make them suitable for a wide range of applications, including the harshest environments and where space is limited. The specification and configuration options of the M100 have also been developed to provide a replacement for the I-1000 series. Using the same IP65/NEMA4 industrial enclosure, they are a direct and convenient replacement option, but introduce the improved measurement performance and features of current digital technology. M M100-Series I Key features: R • • • • • • • S Range summary: T T E High accuracy and excellent long term stability Cable and duct mount versions Measurement of humidity and temperature Large measurement range: 0...100 %RH, -30...150 °C 2-wire loop 4...20 mA or 3-wire types available Calibration using HygroPalm handheld PPS probes with sealed cable M120 M130 M132 Humidity and temperature measurement, 2 x 2 wire loop powered, 4... 20 mA signals Humidity and temperature measurement, 3-wire type, all standard signals, low voltage supply Humidity and temperature measurement, 3-wire type, all standard signals, mains supply Order Information for M100 Transmitters M100 Series Transmitter Feature Power supply *15 V for 0...10 V & current signals 2 x 2- wire loop power , 4...20 mA 3-wires, 12(15)*...35 VDC / 12....24 VAC supply 3-wires, 230 VAC mains supply Measured parameters Humidity and temperature Humidity only Probe type Cable mount Duct mount Probe format 15 mm PPS probe Probe length 250 mm Cable length 2m Duct probe Output signal 0...20 mA 4...20 mA 0...1 V 0...5 V 0...10 V Electrical connection M16 cable gland M12 cable glands Measurement range = output signal Humidity: always 0...100 %RH Temperature none 0...100 °F 0...200 °F 0...100 °C -30...70 °C Special Range Filters must be ordered separately. See page 114/115 52 M1 20 30 32 HT HX X C D P 3 2 X 1 2 3 4 5 M1 M2 X 1 2 3 4 S M10 0-Series Light Industrial Transmitters T R Technical Data M100-Series Specification Humidity sensor Temperature sensor Circuit type Output signals Operating range at the probe Operating range electronics M120 M130 M132 Capacitive Rotronic Hygromer® IN1 sensor Pt100 RTD Class B 1/3 DIN 2-wire loop powered 4...20 mA 3-wires 4...20 mA 0...1 V, 0...5V, 0...10 V, 0...20 mA, 4...20 mA -30...150 °C / 100 %RH up to 85 °C / 90 %RH at 90 °C / 50 %RH at 120 °C 0...99 %RH, non-condensing / -40...60 °C Standard output ranges Accuracy at 23 ±5 °C Repeatability Long term stability humidity sensor Response time (without filter) On-site adjustment Power supply 0...100 %RH / 0...100 °C / -30...70 °C ± 1.5 %RH and ± 0.3 K ± 0.3 %RH and better than ±0.1 K better than 1 %RH per year 10 seconds (%RH and temperature) Requires HygroPalm 3 calibrator and service cable ACRLXB5 10...28VDC 12...35VDC / 12...24 VAC Min. 10 V+ (0.02 x Load*) (min. 15 VDC for 10 V * Load in Ohms and current signals) 20 mA per output < 50 mA 250 Ω 250 Ω N/A 1000 Ω Terminals and cable glands Wire mesh 20 m /s ABS IP65 / NEMA 4 / UL-94 HB compliant Power consumption Max. load current outputs Min. load voltage outputs Electrical connections Sensor protection (Standard) V max. at probe Housing material Protection ratings Dimensions Housing: Probe: Probe cable: Weight CE Conformance A N S M I T T E R 90...250 VAC , 3.5 VA S 160 (L) x 80 (W) x 55 (H) mm Ø 15 or 15 /25 x 250 mm (standard) Ø 15 x 100 mm(optional) 2m (M120C / M130C / M132 C) 370 to 560 g, depending on model and probe configuration EN61000-6-2:2001, EN61000-6-4:2001 Schematic K4 K4 K5 1 +1 K5 1 1 1 3 3 2 + – 2 Ue UB UB M120 2 x 2-wires 4...20 mA current signals 2 4 M130 3/4-wires 0...10 V voltage signals K4 1 RL RL 2 2 2 RL K3 RL K1 +1 4 M130 3/4-wires 0(4)...20 mA current signals K5 K4 K5 1 1 1 3 UB 2 3 M132 3/4-wires 0...10V voltage signals 3 UB 3 4 RL RL 2 M132 3/4-wires 4...20 mA current signals 3 2 4 Dimensional diagrams 55 L = 100 / 250 / 400 / 550 / 700 mm 80 50 Ø 4,2 160 Ø 15 31,5 148 L L 53 ROTRONIC M-Series Transmitter T R A N S M I General Description The new ROTRONIC M-Series transmitters are the latest development of combined humidity / temperature transmitters, based on HygroClip technology. Output signals of 0…1 V, 0…5 V, 0…10 V, 0…20 mA or 4…20 mA are available. The M-Series consists of three models, each offering different features to suit the application requirement, with the facility for most units to be reprogrammed by the customer or reseller. The main features of the three M-Series are as follows: M1 Humidity and temperature transmitters with fixed probe, with electronics based on digital technology M2 Humidity and temperature transmitter with interchangeable HygroClip probes M3 Humidity, calculated humidity (e.g. dew point, enthalpy) and temperature transmitter with interchangeable HygroClip probes T M1 T Key features E • • • • • • • • • • • • • R S High accuracy and excellent long term stability Wall, space and duct mount versions with fixed probe Compatible with FT/FH-Series base plate (except M1xS types) Retractable probe on space mount versions Combined relative humidity and temperature measurement Humidity or temperature only versions available Digital technology Wide measuring range 0…100 %RH, -40…60 °C Diagnosis and calibration with handheld instrument Industry standard output signals (current / voltage) Wire mesh filter provides sensor protection against dust and high air velocity. IP65 / NEMA4 housing; IP52 / NEMA5 for space version Optional display (space version only) Ordering Information - Standard M1 with fixed probes M1 Specification Probe Type Electrical Connection *15 V for 0...10 V & current signals Description Integrated probe 2 wire 4...20 mA 12(15)*...35 VDC /12...24 VAC, 3/4 wires Mounting type Duct Wall Space Output parameters Humidity and temperature Humidity only Temperature only Output signal 0...20 mA 4...20 mA 0...1 V 0...5 V 0...10 V Output range (Scaling of the output signal) Temperature and humidity 0… 50 °C / 0…100 %RH -30…70 °C / 0…100 %RH 0…100 °C / 0…100 %RH No Temperature Output 1 M 2 1 3 4 5 6 H H X T X T 7 8 9 10 - 1 2 3 X 2 3 D W S 1 2 3 4 5 The probe length of all duct mount transmitters is 207 mm; 100 mm for wall mount. Note: Space mount transmitters of the M-series with current output signals inevitably suffer from a degree of ‘self heating’ as a result of the proximity of measurement sensors to the electronics. The effect has been minimized by careful design of the enclosure, pcb and probes In addition, an active compensation system is now integrated into the circuit design, but for this to function correctly the transmitter should be allowed to equilibrate in its installation position for 30-60 minutes (depends on ambient temperature) before the most precise values are obtained. 54 ROTRONIC M-Series Transmitters T R M22 / M23 A Humidity and temperature transmitters for interchangeable HygroClip S probes. N Key features • • • • • • • • • • • • S Probe interchangeable within seconds Wall and duct mounting types Compatible with FT/FH-Series base plate Measures humidity and temperature simultaneously Use of digital technology Wide measuring range High accuracy ±1.5 %RH, 0.3 K and excellent long term stability Optional display Diagnosis and calibration with hand-held instrument Temperature range -40…60 °C / -30…60 °C with integrated display Wire mesh filter provides sensor protection against dust and high air velocity. IP65/NEMA4 housing M I T T E R By means of simulators, the entire measuring section can be validated. Simulators create a defined value both for humidity and temperature. See page 118. S Ordering Information - Standard M2 for interchangeable probes Specification Probe type Electrical connection *15 V for 0...10 V & current signals Mounting type Options 1 M Interchangeable HygroClip probe 2 wire 4...20mA (no display possible) 12(15)*...35 VDC /12...24 VAC, 3/4 wires Duct Wall LC Display (not for M22) No display Output signal 4...20 mA 0...20 mA 0...1 V 0...5 V 0...10 V Output range (Scaling of the output signals) Humidity and temperature 0…100 °F / 0…100 %RH 0…200 °F / 0…100 %RH -50…150 °F / 0…100 %RH 0…100 °C / 0…100 %RH 0… 50 °C / 0…100 %RH -30… 70 °C / 0…100 %RH Special Temperature Range 2 2 3 4 5 6 7 8 - 1 2 3 4 5 6 S 9 10 2 3 D W D N 1 2 3 4 5 The probe length of all M2 standard duct-type transmitters is 250 mm; 100 mm for wall mount types. Standard versions are defined in the price list. HygroClip Probe for M2-Series transmitters HygroClip S Standard sensor module for humidity and temperature. A wire mesh filter provides sensor protection against dust and high air velocity. Dimensions: Ø15 x 100 mm. IP rating: IP65 / NEMA4 Measurement range: -40…85 °C, 0…100 %RH Accuracy: ±1.5 %RH, ±0.3 K (at 23 ±5 °C) Order code: HygroClip S 86.3 Probe extension cables To connect HygroClip S probes to the M2-Series transmitters 1 m length 2 m length 5 m length 79 ø1 5 75.3 Order code: MOK-01-DAT05 MOK-02-DAT05 MOK-05-DAT05 55 ROTRONIC M-Series Transmitters T R M33 A M3 transmitters use the interchangeable HygroClip S probe, and provide outputs of humidity, temperature and calculated parameters such as dew point, wet bulb temperature and enthalpy. N S Key Features M • • • • • • • • • • • • • • • I T T E R S Psychrometric calculations (dew point, enthalpy etc.) Probe interchangeable within seconds Wall- and duct-mounting types Compatible with DPT-Series base plate Measures humidity and temperature simultaneously Use of digital technology Large measuring range Excellent long term stability High accuracy Optional display with trend indicator Remote diagnosis with handheld instrument Temperature range -40…60 °C; -30…60 °C with display Wire mesh filter provides sensor protection against dust and high air velocity. IP65 / NEMA4 housing The M33 transmitters can be networked via RS485 By means of simulators, the entire measuring section can be validated. Simulators create a defined value both for humidity and temperature. See page 118. Order codes for standard M3-Series (other custom types can be defined on page 57) Order code* For ordering information within North America please contact us at: Rotronic Instrument Corp. 160 E. Main Street Huntington, NY 11743 800-628-7101 Visit our website at: www.rotronic-usa.com The probe length of all M3 standard duct-type transmitters is 250 mm; 100 mm for wall mount types. * Probes must be ordered separately, see below. HygroClip Probes for M-Series transmitters HygroClip S Standard sensor module for humidity and temperature. A wire mesh filter provides sensor protection against dust and high air velocity. Dimensions: Ø15 x 100 mm. IP rating: IP65/NEMA4 Measurement range: -40…85 °C , 0…100 %RH Accuracy: ±1.5 %RH, ±0.3 K (at 23 ±5 °C) Order code: HygroClip S 86.3 Probe extension cables To connect HygroClip S probes to the M2-Series transmitters ø1 5 75.3 56 79 Order code: MOK-01-DAT05 MOK-02-DAT05 MOK-05-DAT05 1m 2m 5m ROTRONIC M-Series Transmitters T R Order Codes M33 types with calculations (standard versions are defined in the price list) A Specification 1 2 M3 M 3 3 4 5 6 7 8 9 10 11 12 13 N S M Electrical connections 12(15)*...35 VDC/12...24 VAC, 3/4 wires *15 V for 0...10 V & current signals Mounting type Duct Wall 3 I T D W T E Option Display No display D N R S Output signal 4...20 mA 0...20 mA 0...1 V 0...5 V 0...10 V Output parameters Humidity and calculated parameter Temperature and calculated parameter Humidity and temperature Output range (Scaling of the temperature output signal) Humidity output signal is always 0...100 %RH Calculated parameter No temperature output signal 0…100 °F 0…200 °F -50…150 °F 0…100 °C 0…50 °C - 30…70 °C Special range Dewpoint Wetbulb temperature Enthalpy Specific absolute humidity Mixing ratio Specific humidity Partial pressure Vapor concentration 1 2 3 4 5 - 1 2 3 - X 1 2 3 4 5 6 S 1 2 3 4 5 6 7 8 Note: Output assignment: On M33 transmitters with calculated parameters, output 1 is always assigned to the calculated parameter or, if no such parameter is configured, to the humidity signal. The temperature signal is always assigned to output 2. Adjustment: The transmitters of the M-Series can be adjusted easily by the handheld HygroPalm instrument. 57 Technical Data M-Series T R A N S M I T T E R S Specification Humidity sensor Temperature sensor Probe connection Service Interface Display Display units M1xD & M1xW M1xS Hygromer® AC-1 Pt100 1/3 DIN Integrated probe (%RH/ °C) DIO / Via HygroPalm PC direct RS232 No display option Option %RH, °C, °F Display resolution Output signal Trend indication RS485 interface Serial number in EEPROM Scaleable output signal Electronics operating range Measurement range (probe) Humidity Temperature Output scaling (humidity) Output scaling (temperature) N/A 0.1 %RH / 0.1 °C N/A 0…1/5/10 V, 0…20 mA, 4…20 mA 4…20 mA No Yes on display No No Yes Yes, with HW3 software and HygroPalm No -40…60 °C, versions with display -30…60 °C 0...100 %RH Probe dependant max. -40…85 °C Scaleable Scaleable between -40...100 °C M22x M23x 1 for HygroClip probe (%RH/ °C) No display option 0...100 %RH -50...100 °C or -30...70 °C Option %RH, °C, °F, calculated value 0.1 %RH / 0.1 °C; 0.01 calculated value 0…1/5/10 V, 0…20 mA, 4…20 mA Yes on display Yes Yes, with HW3 software Scaleable Scaleable between -50...100 °C Accuracy at 23 °C ±1.5 %RH /±0.3 K Probe dependant With probe extended N/A ±1.5 %RH/± 0.3 K N/A Reproducibility Probe dependant Long term stability < 1 %RH / Year Adjustment functions 1 point %RH, °C Yes, with HygroPalm 4 point %RH, 2 point °C Yes, with HygroPalm Against reference probe Yes, with HygroPalm Calculations and constants Psychrometric calculation No computations possible Pressure compensation N/A of calcualted value Default pressure constant N/A Transmitter remote functions with HygroPalm 3 Transmitter/probe adjustment Multi-point adjustments Adjustment against reference Yes, one point adjustment against reference probe on HygroPalm 3 Measurement display Yes Transmitter status Yes Electrical specifications Power supply 2-wire types 2-wire 4…20 mA, 10… 28 VDC, min. 10 +(0.02 x load) N/A 3/4-wire types Maximum load Automatic load compensation Electrical connections Mechanical Data Enclosure rating Sensor protection Maximum air velocity Housing material Probe length/diameter for duct mount types Probe length/diameter for wall mount types Dimensions Weight M33x HW3 or HygroPalm Yes Possible with HW4 software 1013.25 hPa 12(15)*…35 VDC /12…24 VAC 12(15)*…35 VDC /12…24 VAC *15 V for 0…10 V & current signals N/A *15 V for 0…10 V & current signals Current output: ≤ 250 Ω; 2-wire at 24 V 500 Ω; Voltage output ≥ 1000 Ω No Terminals on mounting base plate / M16 cable gland Yes IP 65 / NEMA4 Type D15G 20 m/s ABS IP20/ NEMA1 Plastic cage 3 m/s IP65 / NEMA4 Wire mesh filter, stainless steel 20 m/s 207 x 15 mmØ N/A 250 x 15 mmØ 100 x 15 mmØ 154 x 73 x 48 mm Approx. 300 g 38 x 10 mmØ 82 x 82 x 27 mm Approx. 170 g 100 x 15 mmØ 154 x 73 x 48 mm Approx. 300 g Note: Space mount transmitters of the M-Series with current output signals inevitably suffer from a degree of ‘self heating’ as a result of the proximity of measurement sensors to the electronics. The effect has been minimized by careful design of the enclosure, pcb and probes. In addition, an active compensation system is now integrated into the circuit design, but for this to function correctly the transmitter should be allowed to equilibrate in its installation position for 30-60 minutes (depends on ambient temperature) before the most precise values are obtained. 58 M-Series Schematic and Dimensional Diagrams 3 / 4 wire supply current signal 0/4…20 mA 2 or 2 x 2 wire supply 4…20 mA T R 10(15)*…35VDC /12…24 VAC *15 V für 0…10 V & current signals A N S M I T Terminal 3 / 4 wire supply voltage signal 10(15)*…35VDC /12…24 VAC *15 V für 0…10 V & current signals 1+ M1 series Term Detail Supply max. 35 V DC, 24 V AC 2– GND Common ground 3+ Temperature Temperature value as voltage or current signal 4+ Humidity Humidity value as voltage or T E R current signal (M33 only) 5+ + RS485 RS485 Positive Signal (only M33) 6– – RS485 RS485 Negative Signal (only M33) S Only 2- wire and 2 x 2 wire types: 1/3 Supply Supply 15…28 VDC, 2- resp. 2 x 2 wire 2 Temperature Temperature signal 4...20 mA 4 Humidity Humidity signal 4…20 mA Base plate M- series M2 / M3 series (compatible with F/T series) M16 Cable gland North American Market – M1 series includes a 100 mm wall mount probe. M1xS instruments Base plate M1xS Note: Terminal 5 & 6 are reserved for direct Pt100 connection. 59 Roline L-Series Transmitters T R A The Roline L-transmitter has been designed for cost sensitive applications where the highest accuracy or widest measuring ranges are not required. Two versions are available, 2 wire 4…20mA loop and 3/4 wire formats for current and voltage signals. N S M I T T E Key features Your benefits ● Cost effective ➤ Suitable for volume applications ● Compact, well designed instruments ➤ Easy to install ● Excellent long term stability ➤ Reliable data and reduced maintenance ● All standard output signals available ➤ Compatible with most control systems ● Aesthetic housing ➤ Suitable for public areas R S L12 • • • • • • • • • • 2 wire or 2x2 wire loop powered 4…20 mA Integrated probe Duct and wall mounting versions Combined humidity and temperature measurement Humidity or temperature only versions Use of digital technology Excellent long term stability Good accuracy Temperature range 0…50 °C Humidity range 0…100 %RH L13 • • • • • • • • • • • 3/4 wire model for 10 (15)…35 VDC /12…24 VAC supply 4…20 mA, 0…20 mA, 0…1 V, 0…5 V, 0…10 V outputs Integrated probe Duct and wall mounting versions Combined humidity and temperature measurement Humidity or temperature only versions Use of digital technology Excellent long term stability Good accuracy Temperature range 0…50 °C Humidity range 0…100 %RH L1xS • • • • • • • • • • • 60 Space mount transmitter with 2, 2x2 and 3/4 wire technology 4…20 mA, L13S - 0…20 mA, 0…1 V, 0…5 V, 0…10 V outputs Integrated probe Duct and wall mount versions Combined humidity and temperature measurement Humidity or temperature only versions Use of digital technology Excellent long term stability Good accuracy Temperature range 0…50 °C Humidity range 0…100 % Roline L-Series Transmitters T R Ordering Information Roline L-Series (standard types are defined in the price list) A Specification Roline L with integrated probe Electrical connections Mounting Output parameters Output signal 2, 2 x 2-wire 4...20 mA 12*...35 VDC, 3/4 wire Duct (probe length 205 mm) Wall (probe length 55 mm) Space Humidity and Temperature Humidity only Temperature only 0...20 mA (not for L12) 4...20 mA 0...1 V (not for L12) 0...5 V (not for L12) 0...10 V (not for L12) 1 2 L 1 3 4 5 6 7 N S 2 3 M D W S I T 1 2 3 T 1 2 3 4 5 E R S North American Market: Specify temperature output signal “C” (0…50 °C) or “F“ (0…100 °F) * 15V for 0/4…20mA and 0…10V Note: Space mount transmitters of the L-Series with current output signals inevitably suffer from a degree of ‘self heating’ as a result of the proximity of measurement sensors to the electronics. The effect has been minimized by careful design of the enclosure, pcb and probes. In addition, an active compensation system is now integrated into the circuit design, but for this to function correctly the transmitter should be allowed to equilibrate in its installation position for 30-60 minutes (depends on ambient temperature) before the most precise values are obtained. Technical data Roline L-Series Specification Humidity sensor Temperature sensor Output signal type Transmitter adjustment Measurement range Humidity Temperature Output scaling Temperature compensation Accuracy at 23°C Reproducibility Long term stability Supply Current consumption Max. Load for current output Min. Load for voltage output Electrical connections Maximum air velocity Enclosure rating Housing material / fire resistance Dimensions Duct mount Wall mount Space mount Weight *15 V for 0...10 V and current signals L12 L13 Hygromer® AC-1 Pt 100 1/3 DIN 2, 2x2-wire, 4…20 mA 0…1/ 5 /10 V; 0/4…20 mA With HygroPalm 3 handheld instrument 0…100 %RH (non condensing) -40…60 °C Scaleable Yes ±3 %RH / ±0.5 K < 0.6 %RH / 0.5 K < 1 %RH / Year 2, 2x2 wire 4…20 mA 10…28 VDC 10(15)*...35VDC /12...24 VAC Max. 20 mA /output < 50 mA ≤ 250 Ω ; with 24 V supply ≤ 500 Ω < 250 Ω >1000 Ω/V Screw terminals / M16 cable gland L1xD & L1xW: Max. 20 m/s; L1xS: max. 3m/s Duct/wall mount IP 65 / NEMA4; Space mount IP 52/NEMA5 ABS/PP-H / UL94 HB compliant Ø 82 x 43 mm; Probe length 207 mm; Probe � 15 mm Ø 82 x 43 mm; Probe length 52 mm; Probe � 15 mm 82 x 82 x 27 mm Approx. 200 g 61 S chematic and Dimensional Diagrams for Roline L-Series T R 3 / 4 wire supply current signal 2 or 2 x 2 wire supply 4…20 mA S M I T T E R S 3 / 4 wire supply voltage signal Terminal 10(15)*…35VDC /12…24 VAC *15 V for 0…10 V & current signals N 10(15)*…35VDC /12…24 VAC *15 V for 0…10 V & current signals A Term Detail V+ (1) Supply max. 35 V DC, 24 V AC GND (2) GND Common ground T Out (3) Temperature Temperature value as voltage or current signal H Out (4) Humidity Humidity value as voltage or current signal (M33 only) 3-wire types Only 2- wire and 2 x 2 wire types: V+ Supply Supply 15…28 VDC, 2- resp. 2 x 2 wire T Out Temperature Temperature signal 4...20 mA H Out Humidity Humidity signal 4…20 mA Dimensional drawings Roline L Wall-mount type Duct-mount type L12: M16 Cable gland Roline L 62 AC1625 Space-mount type V+ H Out V+ T Out V+ GND H Out T Out L13: Installation, Maintenance and Accessories T Installation of ROTRONIC transmitters is simple. The various models are mounted using either a mounting plate onto which the whole transmitter is fixed, or by a connection base plate which is screwed onto the wall or duct, or by direct mounting onto a duct by fixing the probe with an AGRO fitting. Some models feature screw holes inside the enclosure, which are sealed against the electronics. R A N S Mounting M HygroFlex HygroFlex transmitters are mounted by a separate mounting plate. The plate is screwed onto the wall, and the transmitter enclosure positioned in place. I T T M120 / M130 E M120 / M130 transmitters can be mounted onto a wall or duct by 4 screws through interior holes. Duct mount probes are fixed by a compression fitting and a flange. R S M-Series The connection base plate of the M-Series is used for mounting. The base plate may be mounted and wired during construction. Once construction is completed the electronics can be plugged in and secured. Roline L Roline L-Series transmitters are mounted onto a duct or wall directly with screw tags. Duct mount probes may also be fixed by a compression fitting and a flange. Maintenance ROTRONIC transmitters require hardly any maintenance. Due to excellent long term stability, a calibration interval of one year will be sufficient in most cases. However, in some applications, for example where pollutants are present, it may be advisable to perform calibrations more often. For detailed calibration information, please refer to the chapter on calibration. In dusty and polluted environments, the sensor protection filters require some maintenance. We recommend that a spare filter be available and to exchange it on site. The soiled filter may be cleaned in the workshop with soap and water. Ultrasonic cleaners may also be used. Allow the filter dry thoroughly before re-use. Installation accessories for all 15 and 25mm diameter probes. If the transmitter electronics are mounted directly onto a wall or duct, no further mounting hardware is needed. If just the probe is installed in a duct, an AGRO compression fitting and flange are used. The flange is used only if the AGRO compression fitting cannot be fastened directly to the duct. Order code Gasket Probe Ø T max. Thread AG H (mm) Flange QMA-15 Viton D 15 mm 200 °C M 20 x 1.5 26 AC 1305 QMA-25 Viton 25 mm 200 °C M 32 x 1.5 31.5 AC 1306 ½" G thread on request Filters: Suitable filters may be found in the chapter Accessories (pages 114 / 115) 63 HygroClip Introduction T R A N S M I T T E R S What is the HygroClip? HygroClip® is a high quality probe for the measurement of humidity and temperature. It is used in a wide range of applications including handheld instruments, dataloggers and transmitters. It provides digital and analog output signals for both temperature and humidity. Different output ranges are distinguished by different colors of the housings. The digital DIO signal is perfectly suited for networked applications. With the digital interfaces DI-LANCLIP, DI-WLANCLIP and DI-USBCLIP, new possibilities for online monitoring applications become available. The digital signal is also suitable for OEM applications. An increasing number of OEMs make use of the digital technology. The probes may be adjusted digitally by either software or handheld instruments such as the HygroPalm-Series. Calibration data is stored in an EE-Prom, therefore the probes can be used with any ROTRONIC display instrument, transmitter, even OEM instruments without the need for further adjustment. ROTRONIC offers an exchange service for the HygroClip probes, where every refurbished HygroClip comes with a new sensor and is supplied with a factory adjustment certificate of conformance. Rotronic’s extensive experience of humidity technology, coupled with the HygroClip’s unique range of features and benefits provides us the opportunity to satisfy the measurement and practical needs of any user. As the first manufacturer to provide an interchangeable humidity probe concept, and through continuous dialogue with our customers, we continue to expand the performance, quality and advantages for the benefit of our customers. Key features Your benefits ● Simple replacement within seconds ➤ Negligible down time; reduction of servicing costs ● No on-site adjustment necessary ➤ No specific knowledge required, minimal site time ● Global availability from stock ➤ Available from your local dealer ● Digital output signal ➤ High accuracy and interchangeability ● Analog interface ➤ Also suitable for analog display instruments ● Wide supply voltage range ➤ Suitable for almost every OEM instrument ● Networkable over USB, RS485, TCP/IP ➤ Easy monitoring OEM applications and advantages The availability of digital and analog output signals and the wide supply voltage range of 3.5 to 24 VDC makes the HygroClip suitable for a wide variety of applications. The application ranges of 0…100 %RH and -40 to 85 °C are unique, they cover the majority of application requirements. HygroClip S is the standard type. However, ROTRONIC is capable of manufacturing customized types according to your requirements. The HygroClip is ideally suited as an integral part of complete humidity and temperature measurement systems, such as: ● ● ● ● ● Display devices Process control applications Multi channel data loggers Handheld instruments High precision climate control ● ● ● ● ● ● Electronic cabinets Incubators and environmental chambers Fermentation chambers EDP applications Gas detection systems & portable instrumentation Air conditioned containers Section contains HygroClip Probe ● ● 64-66 Standard HygroClip S HygroClip S3 for meteorological applications HygroClip Interfaces ● ● 67 TCP-IP: RJ45 and wireless LAN USB HygroClip Accessories ● 64 Accessories for HygroClip probes 68-71 HygroClip T R Feature Overview A N Replaceable sensor protection filter Universal probe for multiple applications S M I T T E R Compact dimensions – suits many applications S Probe body filled with resin to avoid condensation IP-65/NEMA4 protection Analog and digital interfaces Available for standard and meteorological applications Sockets with lock-ring 3.5...24 VDC supply voltage OEM-types available 65 T R A N S HygroClip S and Accessories The majority of ROTRONIC instruments use a HygroClip S probe for the measurement of humidity and temperature. The probe is used in combination with handheld instruments, data loggers and transmitters. Many OEM customers use it either as a transmitter or sensor module in their own products. HygroClip probes are interchangeable without adjustment. HygroClip probes can actually be connected and networked directly by a TCP/IP (LAN or W-LAN) interface to a PC. This allows cost effective on-line monitoring for various applications. A USB interface is also available. These types may also be networked by RS485. M I T T E R S HygroClip S • • • • • • • • • 100 % interchangeable 1 digital and 2 analog outputs ROTRONIC Hygromer humidity sensor 0...100 %RH Accuracy: Standard ±1.5 %RH, ±0.3 K (at 23 ±5 °C) Long term stability better than 1 %RH / year High precision Pt100 1/3 DIN temperature sensor Short response time Includes wire mesh filter Black housing Order code: HygroClip S Standard probe with factory certificate of conformance 0...100 %RH = 0...1 V / -40...85°C = -0.4...0.85V N.I.S.T. traceable Certificate of Calibration available upon request HygroClip S3 HygroClip S3 is the meteorology version of the HygroClip S • • • • • • • • • 100 % interchangeable 1 digital and 2 analog outputs ROTRONIC Hygromer humidity sensor 0...100 %RH Accuracy: Standard ±1.5 %RH, ±0.3 K (at 23 ±5 °C) Long term stability better than 1 %RH/year High precision Pt100 1/3 DIN temperature sensor Short response time Includes wire mesh filter White housing Order code: HygroClip S3 Standard probe with factory certificate of conformance 0...100 %RH = 0...1 V / -40...60 °C = 0...1 V N.I.S.T. traceable Certificate of Calibration available upon request Note: These probes feature a DAT05 connector. The order codes of probes available with a Binder 5-pin connector have the suffix–B5 For more HygroClip probes: see pages 10-11 MOC, MOC 3 • • • • • Mounting connector for HygroClip S 30 cm connecting wires Mounting hole 12.7 mm diameter or PG7 thread HygroClip connector with bayonet locking ring MOC3 in white for HygroClip S3 Order code: MOC MOC 3 66 (black) (white) HygroCli p S and Accessories HygroClip DI Interfaces T R A The new cost effective DI interfaces allow the networking of up to 64 devices using an RS485 network with a master interface unit connecting to a PC using either an Ethernet, Wireless LAN or USB interface. The HygroClip interface units can be integrated onto existing networks of data loggers and / or transmitters. N One or two HygroClip probes may be connected to the interface units. With the user friendly HW4 software, the devices can be configured, monitored and managed. Adjustment and calibration by software is also possible via the network. M The interfaces are available in three different versions: DI-3 • • • • • • • I T T USB PC Interface 2 digital HygroClip probe connections Connector for mains adaptor Operating range -40...85 °C Software compatible with ROTRONIC HW4 RS485 bus interface Power supply available via RS485 cable Order code: S E R S DI-3 DI-4 • • • • • • • Ethernet LAN TCP/IP interface (RJ45) 2 digital HygroClip probe connections Connector for mains adaptor Operating range -40...85 °C Software compatible with ROTRONIC HW4 RS485 bus interface Power supply available via RS485 cable Order code: DI-4 DI-4-WL • • • • • • • Wireless LAN TCP/IP interface 2 digital HygroClip probe connections Connector for mains adaptor Operating range -40...85 °C Software compatible with ROTRONIC HW4 RS485 bus interface Power supply available via RS485 cable Order code: DI-4-WL Probe connections and cables The two 5-pin Binder connectors accept HygroClip probes with B5 connectors, while probes with a DAT05 or Industrial Tuchel connector require an adaptor cable. Order code: MOK-01-B5 T7-0.5-B5 1 m adaptor cable for probes with DAT05 connector (see next page) 0.5 m adaptor cable for probes with Industrial Tuchel 7-pin connector (see page 119) 67 HygroClip S and Accessories T R MOK, MOK3 A Passive extension cables for HygroClip S and S3 (no electronics) • 2 or 5 m connection cable with stripped wires • 5-pin Binder connector or DAT05 connection to extend cable length N S Active adaptor: with integrated amplifier • Ranges 0…1 V, 0…2.5 V, 0…5 V, 0…10 V at 0…100 %RH and, for example -40…60 °C • Length of connection cable up to 20 m • MOK3 in white for HygroClip S3 M I T T E R S Order codes MOK adaptors Order codes passive adaptors Standard type (anthracite) White housing Cable length: 1m 2m 5m Stripped wires Binder 5 pin connector DAT05 connector (HygroClip-plug) 1 2 M O Order codes active adaptors Anthracite housing (Standard type) White housing 1 2 M O Cable length 2m 5m Stripped wires Output signal 0…1 V 0…5 V 0…10 V 3 K 3 K 4 3- 4 3- 5 6 0 0 0 1 2 5 5 6 0 0 2 5 7 8 9 10 11 12 13 14 15 16 - X B D X 5 A 7 8 9 10 11 12 13 14 15 16 - X X (min. supply 5.5 V) (min. supply 10 V) (min. supply 15 V) T - 0 0 0 0 5 0 0 1 Not for MOK3 1 5 0 Remarks Max. cable: 2m 10 m 20 m V V V - Temperature range 0…100 °C ( not possible for MOK3-XX) -30…70 °C (not possible for MOK3-XX) -40…60 °C Minimum load: 1 kΩ/V 1 2 3 HygroWin HygroWin is a probe for direct connection to the RS232 interface of a PC, to be used for example to monitor climatic data in a wine cellar or similar. • • • • • • 15 mm probe for direct connection to a PC with a serial port DB25 / DB 9 adaptor Measurement range 0...100 %RH, -25...85 °C Accuracy ±3 %RH, ±0.5 K (at 23 ± 5°C) Comprehensive software with data storage Cost effective probe Not adjustable Order code: HygroWin AC1207 Probe with software Mains adaptor Note: Some PCs may not provide sufficient power on the COM port. We recommend powering the HygroWin with the optional mains adaptor AC1207. 68 HygroCli p S and Accessories R MOK-xx-WIN With the calibration cable MOK-xx-WIN, HygroClip probes can be calibrated /adjusted directly with a PC. • • • • • • Direct PC connection including a serial port DB25 / DB 9 adaptor Cable length: 1 m, 2 m, 3 m Use with calibration software HW3 Printing of calibration certificates if so desired Fitted with power connector Maximum supply voltage 27 VDC Order code: MOK-01-WIN MOK-02-WIN MOK-03-WIN T7-03-WIN AC1207 T A N S M I T for probes with DAT05 connector, with 1 m cable for probes with DAT05 connector, with 2 m cable for probes with DAT05 connector, with 3 m cable for probes with Tuchel T7 connector (Industrial type), with 3 m cable Mains adaptor Note: Some PCs may not provide sufficient power on the COM port. We recommend powering the probe / cable using the probe with the optional mains adaptor AC1207. Order HygroClip probes and HW3 software separately. T E R S HygroClip Simulators For system validation, ROTRONIC offers HygroClip simulators for both Industrial probes with Tuchel 7-pin connector and probes with DAT05 connector. A HygroClip simulator generates a fixed digital value for both humidity and temperature, which is provided as digital and analog output signals. These signals serve as fixed data points, providing instrument calibration and loop validation. Simulators with DAT05 connector Order code: HCLP-S-35RH/25C simulates 35 %RH and 25 °C HCLP-S-80RH/25C simulates 80 %RH and 25 °C Simulators with Tuchel 7-pin connector (Industrial types) Order code: AC1618/20/25 simulates 20 %RH and 25 °C AC1618/50/18 simulates 50 %RH and 18 °C Details and order information see page 118. HPH Signal Booster • Allows cable lengths up to 99 m • Cable length compensation, therefore no measuring errors when using long cable runs • ROV interface (10 mV/ %RH, 10 mV/ °C, 0 %RH, 0 °C = 0 V) Order code: HPH-CG05B5 HPH-CG99B5 HPH-CG05XX HPH-CG99XX Booster, 5 m connecting cable with Binder 5-pin connector Booster, connecting cable up to 99 m selectable, Binder 5-pin connector Booster, 5 m connecting cable, stripped wires Booster, connecting cable up to 99 m selectable, stripped wires Technical data of the HPH signal booster Outputs Cable length Cable compensation Connecting cable Humidity Temperature 0…100 %RH = 0…1 V (N.B. DIO digital signal is not available via the HPH) -40…85 °C= -0.4…0.85 V 2…99 m Up to 99 m Open terminations or 5 pin connector 69 HygroClip S and Accessories T R HygroClip Technical data, Order Information A N S M I T T E R S Supply voltage Current consumption Operating range Accuracy at 23 °C Output signals Digital output signal Start up time Resolution HygroClip HygroClip 3.5…24 VDC Approx. 4 mA 0…100 %RH / -40…85 °C ±1.5 %RH / ±0.3 K Humidity /Temperature 0…100 %RH = 0…1V / -40…85 °C = -0.4…0.85V Humidity /Temperature 0…100 %RH = 0…1V / -40…60 °C = 0…1V One Wire DIO 2.7s first measurement; 0.7 s subsequent 0.02 %RH Analog, 0.004 %RH Digital 0.06 °C Analog, 0.004 °C Digital Via PC (EE-Prom) or compatible instrument <0.5 %RH <0.1 °C Hygromer AC-1 / Pt100 1/3 DIN >10 kOhm max. 5 m Wire filter (max. 20 m/s) 100 x 15 mm IP65/NEMA4 Black RAL 7016 White PC Novarex 7022 No. 31204, corresponds to RAL 9010 HygroClip S HygroClip S3 Humidity Temperature Adjustment Reproducibility Humidity Reproducibility Temperature Sensors Humidity / Temperature Output load Cable length Sensor protection Dimensions with MOC Type of enclosure Color HygroClip S HygroClip S3 Pin and color configuration MOC, MOK, MOK-WIN MOC, stripped wires Term Wire color +VDC Green GND Black Shield (GND) N/C Temperature Brown Humidity White DIO Signal Yellow Compensation N/A Pin 2 3 3 1 5 4 N/A MOK B5 Plug Wire color Green Grey and Blue Shield Pin 2 3 1 5 Yellow N/A 4 MOC MOK 70 HPH B5 Plug Wire color Green Grey N/C Brown White Term TXD RXD RTS SG DTR MOK-WIN D-sub 25 plug 2 3 4 7 20 Yellow Pin 1 2 3 4 5 Color brown green black yellow white Function Temperature +VDC GND DIO Rel. humidity Pin 1 2 3 4 5 Color brown green grey/ blue yellow white Function Temperature +VDC GND DIO Rel. humidity Pin 1 2 3 4 5 Color brown green grey yellow white Function Temperature +VDC GND Compensation Rel. humidity App li cat io n examples for Digital Interfaces T R DI-3 A MOK-XX-B5 N S M MOK-XX-B5 I T AC1614/xx RS485 T E AC1211 R S USB DI-4 MOK-XX-B5 MOK-XX-B5 RJ45 (Ethernet) LAN AC1614/xx RS485 AC1211 DI-4-WL MOK-XX-B5 MOK-XX-B5 Wireless LAN AC1614/xx RS485 AC1211 71 Introduction M E T E O R O L O G Y In Meteorology, the accuracy of the climatic measurement data is essential for accurate forecasting and decision making. ROTRONIC humidity probes have an excellent reputation for providing reliable results, even in the most demanding conditions where high humidity and low temperatures can prevail. Our current product range offers high performance, wide range of configurations and price levels that are compatible with any application’s demands. ROTRONIC also supplies ventilated shields that provide improved protection from rain, snow and radiation, and, most importantly, improve the accuracy of temperature measurement. Compared to previous generations of ventilated shields, the performance has been greatly improved. In practice it matches the values measured by the widely used, but expensive, condensation hygrometers that represent the reference in many national meteorological organizations throughout the world. This is not to say they are an alternative, more that they will provide high levels of performance in cost sensitive situations. Why is the correct temperature essential? In the past, combined temperature and humidity probes have been integrated into weather stations, or screens (such as the Stevenson type), usually made of wood and painted white. Despite the white color, the screens tended to heat up as a result of solar radiation, and the internal deviation from actual temperature could be quite high. Such a deviation obviously leads to incorrect measurement of the humidity, because relative humidity is temperature dependent. Example: Assuming an absolute humidity Q of 5 g/kg; the relative humidity at 20°C is 34.74 %RH; at 21°C 32.66 %RH and at 19°C 36.97 %RH. Hence, it is clear that an incorrect temperature measurement will result in an incorrect relative humidity value. The new ROTRONIC ventilated weather shields minimize thermal effects and provide for improved temperature accuracy, as the probe is not as severely effected by solar effects. An air flow constantly cools the shield, and air temperature is measured at the air inlet. Shields developed with The new shields have been developed in cooperation with the Swiss National Meteorological Service. Their tests showed the excellent accuracy of the combination of ROTRONIC meteorological probes and ventilated shields. Key features Your benefits ● High accuracy and stability ➤ Reliable measurement data and low maintenance costs ● Digital probes ➤ No on-site calibration required ● Fast and easy probe exchange ➤ Saves installation and on-site costs ● Ventilated shields ➤ Optimum temperature performance ● Easy mounting ➤ Saves installation and on-site costs Section contents: Weather Protection Shields ● ● ● Probes and Adaptors ● ● ● 72 74 Ventilated weather protection shields Non-ventilated weather protection shields State-of-the-art meteorological probes Analog meteorological probes Digital HygroClip probes MOK cable adaptors for HygroClip 75-79 Meteorology Applications M E ROTRONIC Weather Station for Temperature and Relative Humidity T E O R O L Agronomic applications O G Y Snow guns Alpine observation applications Ice warning systems Weather stations BMS / HVAC applications 73 M E T Weather and Radiation Protection Shields Ventilated weather shield RS-series O The new RS ventilated shield has been developed in close cooperation with the Swiss National Meteorological Service. It is a highly advanced product, designed to minimize the influence of thermal radiation on humidity and temperature measurements, while maximizing protection from the worst weather conditions, including horizontally driven wind and rain. The performance of the RS shield in combination with the latest ROTRONIC meteorological probes is such that in comparative tests, measurement performance was practically identical to reference chilled mirror condensation hygrometers which are used by many National Meteorological Organizations. R All ROTRONIC Meteorology probes can be used in conjunction with the RS-Series shield. E O L O Key features G • • • • Y Easy-to-install protection shield with built-in ventilator Special white paint minimizes solar gain Easy probe mounting 12 VDC or 24 VDC supply for fan and probe Operating range: Material: Color: Fan supply: Aspiration rate: Dimensions: Fan: Lifetime of fan: Order code: RS12T RS24T -30…60 °C Aluminum, POM White, RAL 9010 approx. 2 W 3.5 m/s / 900 l/min see drawing on page 78 Papst fan IP54 70,000 hours @40 °C, 35,000 hours @70 °C Weather shield with 12 VDC ventilator Weather shield with 24 VDC ventilator See diagrams page 78 Mounting kits for RS weather protection shield Order code: MKRS-1-15 MKRS-2-15 MKRS-3-25 MKRS-4-25 MKRS-5-25 Probe used / Adaptor HygroClip S3 HygroClip with HygroFlex-connector MP100/MP400 w. Tuchel 7-pin connector MP100/MP400 w. Tuchel 4-pin connector MP100H /MP400H Cable connection Terminals / Cable glands Terminals / Tuchel 7-pin connector Terminals / Cable glands Terminals / Cable glands Terminals / Cable glands Weather and radiation protection shield with natural ventilation The naturally ventilated shield is recommended for applications where the accuracy is less important. • It offers fairly good protection against radiation and precipitation. • Suitable for humidity and temperature probes series MP100A, MP400A, MP100H, MP400H • Protects against horizontally driven wind and rain up to 68 km/h. • Includes probe protection tube 74 Order code: SMP-41002 SMP-41002A SMP-41202-7 Suitable for: For MP100A series (12 plates) For MP400A, MP100H, MP400H (16 plates) For HygroClip S/S3 probes; in conjunction with AC1002-AC1012 Accessories: ET-234 ET-230 Mating connector Tuchel 7 pin female Mating connector Tuchel 4 pin female MP10 0H / MP40 0H / HygroClip S3 M E MP100H/MP400H for interchangeable HygroClip sensor module T High performance meteorological probe with advanced features and a wide range of configuration options. Key features: E • • • • • O Humidity and temperature measurement using interchangeable HygroClip S3 sensor module Highly accurate temperature measurement option, direct Pt100 sensor element. Temperature operating range: -40…+60 ºC Current or voltage output signals Cable length compensation to 99m (V outputs) R O See page 78 for technical data L O G Order codes for MP100H & MP400H probes Specification: Y 1 Basic model voltage output Basic model current output Without auxiliary Pt100 With auxiliary Pt100, active signal With auxiliary Pt100, passive signal 2-wire With auxiliary Pt100, passive signal 3-wire With auxiliary Pt100, passive signal 4-wire Output signal for MP100H 0…1 V = 0…100 %RH; -40…60 °C = -0.4…0.6 V 0…1 V =0…100 %RH; -30…70 °C 0…1 V = 0…100 %RH; -40…60 °C Output signal for MP400H 4…20 mA = 0…100 %RH, 0…100 °C (max. 60 °C operation) 4…20 mA = 0…100 %RH -40…60 °C 4…20 mA = 0…100 %RH -30…70 °C PUR connection cable (3 m standard) Maximum 99 m 7-pin Tuchel plug (not for 3/4 wire auxiliary Pt100) No cable termination Auxiliary temperature sensor Pt100 1/3 DIN Pt100 1/5 DIN Pt100 1/10 DIN 2 3 4 5 0 9 3 9 6 7 0 * 0 8 9 10 11 12 13 - 0 0 1 MP100HMP400H0 1 2 3 4 1 2 3 7 8 9 3 5 0 N.B. Tuchel 4-pin connector is not possible! * On request HygroClip S3 Standard probe for humidity and temperature measurement in very cost sensitive meteorological applications. Key Features: • HygroClip configured for meteorology applications. • Wire mesh filter to protect sensor Measurement range: Accuracy: Dimensions: Rating: -40...60 °C, 0...100 %RH = 0…1 V ±1.5 %RH, ±0.3 K (at 23 ±5 °C) 100 x 15 mm Ø IP65 / NEMA4 Order Code: HygroClip S3 75 MP101A / MP40 0A M E MP101A with linear voltage output MP400A with linear current output T E Standard type meteorological probe with fixed sensors with high performance based on analog technology. O Key features: • • • • • Accuracy and long term stability Resistant to condensation and air-borne pollutants Temperature operating range: -40…60 °C Temperature measurement by direct Pt100 resistance or linear analog output Cable length compensation circuit; no signal errors for cables up to 100 m with 0…1V output • Universal power supply 5…26.5 VDC • Rapid start up time suits some data acquisition systems R O L O G Y Order codes of standard types: Humidity Range: 0…100 %RH = 0…1 V (MP100A) or 4…20 mA (MP400A) Order Code Temp. Range MP101A-C4 MP101A-C5 MP101A-T7 -0.4…0.6 V = -40…60 °C Connector Cable compensation Amphenol 4 pin Amphenol 5 pin Tuchel 7 pin Yes Order codes of non - standard types MP100 & MP400 (Special Order: North American Market) 76 Column No. Example: 1 2 M P 3 1 4 0 Output signals: Humidity: Temperature: Voltage 0…1 VDC = 0…100 %RH -0.4…0.6 V = -40…60 °C 0…1 VDC = -30…70 °C 0…1 VDC = -40…60 °C Auxiliary Pt100 for 4/4 wire connection M P 1 0 Output signals: Current 0…20 mA = 0…100 %RH / Pt100 4-wire 4…20 mA = 0…100 %RH / Pt100 4-wire 4…20 mA = 0…100 %RH (2-wire) 4…20 mA= 0…100 %RH (2-wire)/ Pt100 4-wire 0…20 mA = 0…100 %RH, 0…100 °C 0…20 mA = 0…100 %RH, -40…60 °C 0…20 mA = 0…100 %RH, -30…70 °C 4…20 mA = 0…100 %RH, 0…100 °C 4…20 mA = 0…100 %RH, -40…60 °C 4…20 mA = 0…100 %RH -30…70 °C Common terms for MP100 & MP400 Version: Integrated Tuchel 4-pin connector Integrated Tuchel 7-pin connector Connection cable: PUR cable, grey Cable length: 2m (for example) Cable plug: Cannon 4-pin connector Without plug, stripped wires M P 5 1 6 A 7 8 9 10 11 12 13 14 - T7 - W 4 W - - 0 1 2 3 4 5 6 7 8 9 A T4 T7 CG 02 C4 00 Operating range: -40…60 °C 0 Sensor protection: Wire filter 4 Humidity sensor: Hygromer® IN-1 1 2 3 6 HygroClip Probes HygroClip S3C03 for meteorological applications Typical applications include low cost weather stations and data acquisition systems. Fitted with 3 m cable (un-terminated) • • • • • • • • Approved by Meteo France Precise and stable measurement of temperature and humidity Economical price Configured for outdoor measurements Compact dimensions Weather protection shield available Technical data equal to HygroClip S3, except cable Available with Pt100 1/5 DIN in 4-wire technique Measurement range: HygroClip S3: Accuracy: Humidity: Temperature: Dimensions : IP rating: M E T E O R O L -40…60 °C, 0…100 %RH = 0…1 V O ±1.5 %RH, at 23 ±5 °C ±0.2 K (at 23 ±5 °C, active) G Ø 15 x 100 mm, 3 m cable IP65 / NEMA4 Order Code: HygroClip S3C03 HygroClip S3C03-PT15 Y Active cable probe (Special Order: North American Market) Probe with passive Pt100 1/5 DIN (Special Order: North American Market) HygroClip S3 Standard sensor module for humidity and temperature designed for meteorology applications . A wire mesh filter provides sensor protection against dust and high air velocity. • • • • Economical price Configured for outdoor measurements Compact dimensions Weather protection shield available Measurement range: HygroClip S3: Accuracy: Humidity: Temperature: ±1.5 %RH, at 23 ±5 °C ±0.2 K (at 23 ±5 °C) Dimensions: IP rating: Ø15 x 100 mm IP65 / NEMA4 -40…60 °C, 0…100 %RH = 0…1 V Order Code: HygroClip S3 MOK Adaptors for meteorology applications with HygroClip Probes The MOK adaptors provide a simple and low cost means of connecting a HygroClip probe to a signal processing device. They can amongst many other applications be used in conjunction with the weather protection shields RS12 / RS24. MOK3-05-XX Passive adaptor without electronics for HygroClip S3 MOK3-…-1/2.5/5/10 V Active adaptors with integrated amplifier Order codes see page 68 77 Technical data M E T E Technical data MP100A, MP400A, MP100H, MP400H Series Output signal type Supply voltage MP101H Voltage 3.6…35 VDC MP100A 4.8...30 VDC O MP400H Current 5.0 + (0.02*Load) VDC, max. 15 VDC R O L O G Y MP400A MP402/403: 8+ (0.02*load) VDC Others: 5+ (0.02*load) VDC max. 26. VDC Power consumption: Load Cable length compensation Operating range electronics Measuring temperature span Measuring range humidity Option humidity only (2/3 wires) Internal temperature sensor type Aux. Pt100 1/5 DIN / 1/10 DIN Option Humidity sensor Accuracy of temperature Accuracy of humidity at 23°C Humidity 0…100 %RH 10…95 %RH <10, >95 %RH Reproducibility Long term stability Time constant at 1m/s air movement Adjustment points (potentiometers) Humidity Temperature Housing material Protection (IP-rating) Weight 10 mA with HygroClip < 10 mA 45 mA with HygroClip > 1 kΩ <500 Ω up to 99 m N/A -40…+60 °C / 0…100 %RH Various temperature ranges in °C, see ordering information 0…100 %RH N/A yes N/A Pt100 1/3 DIN 1/5 DIN 1/10 DIN N/A 1/5/DIN 1/10DIN HygroClip Hygromer® IN-1 HygroClip ±0.2 K 20 mA / 2x20 mA Yes N/A Hygromer® IN-1 ±1.5 %RH N/A N/A ±1.5 %RH N/A ±2.5 %RH Humidity: <0.5 %RH, Temperature = 0.1 K < 1 %RH / year, < ±0.1°C <15 s ±1.5 %RH N/A N/A N/A ±1.5 %RH ±2.5 %RH N/A (HygroClip) N/A (HygroClip) Delrin (POM) IP65/NEMA4 approx. 200 g N/A (HygroClip) N/A (HygroClip) 35, 80, Hmin Tmin, Tmax 35, 80, Hmin Tmin, Tmax SMP-41002 (12 Plates) and SMP-41002A (16 plates) AC1004 1 2 3 4 5 6 7 8 9 10 11 12 50 220 MKRS-1-15 Ø85 90 1 2 3 4 5 6 7 8 9 10 11 12 Technical drawings 153 200 1 2 3 4 5 6 7 8 9 10 11 12 MKRS-2-15 1 2 3 4 5 6 7 8 9 10 11 12 MKRS-3-25 / MKRS-4-25 MKRS-5-25 78 RS12T/ RS24T Dimensional Diagrams M E MP101 A / MP400 A T MP100A-T7 30 25 MP100A-CG TUCHEL PLUG 7P HOUSING: WHITE 210 E PG7 WITH KINK PROTECTION HOUSING: WHITE 40,5 52 O 40,5 252 7 R O MP100H / MP400 H L MP100H / MP400H /-0 MP100H /MP400H / 1…4 O G Y Connector pinning for MP100-, MP400- Series Tuchel T4 Tuchel T7 MP100 Tuchel T7 with separate Pt100 Accessories: Order code: D15G-White Description Filter for HygroClip S3 probes Pore size: 20…25 µm Material Polycarbonate / Wire mesh MF25MP Filter for MP100 /MP400 series Pore size: 20…25 µm Polycarbonate / Wire mesh Cable length compensation The integrated cable length compensation allows the use of a connection cable up to 99 m long, without an adverse affect on measurements. The additional “0” cable wire is connected according to the diagrams shown. The combination of ROTRONIC instruments with ROTRONIC cables includes the cable length compensation facility as standard. The connection from probe to display instrument consists of a 5-core cable, where the shielding may also be used for the common ground. The “0” cable compensation is connected to the common ground “GND” at the display instrument. It is possible to use the probe with a non-ROTRONIC instrument, such as a datalogger, chart recorder or controller and retain the compensation, by connecting the cable compensation “0” to the common ground “GND” of the termination point (the load). The cable compensation “0” can be connected with the common ground “GND” at the plug, if a 5-core cable is extended by a 5-core cable. If this is terminated by a 4-pin plug, in this case the cable compensation is effective in the 5-core cable up to the 4-pin plug. Probes with integrated 4-pin connector: The cable compensation is effective up to the connector. 79 Introduction W A T E R The measurement of Water Activity, or Equilibrium Relative Humidity, as it is sometimes known, is a key parameter in the quality control of any moisture sensitive product or material. ROTRONIC has designed and manufactured instruments for the measurement of Water Activity for over 30 years. Our product range is based on our comprehensive application experience, which when combined with the very latest digital technology and software, offers the user the ideal combination of features, performance and competitive pricing. A Why is water activity measured? C T I V I T Water activity aw = 0.91…0.95 aw = 0.88 aw = 0.80 aw = 0.75 aw = 0.70 aw = 0.65 Contaminant most bacteria most yeast most mildew halophile bacteria osmiophile yeast xerophile mildew Y Water activity defines the active part of a product’s moisture content, or ‘free’ water. It influences the microbiological, chemical and enzymatic stability of perishable products such as foods, grain and seeds. The table shows typical growth thresholds below which the specified contaminant cannot replicate, and therefore spoil the product. Control of water activity therefore has a significant impact on shelf life. For similar reasons, water activity is equally relevant in the pharmaceutical industry where it also provides useful information regarding properties such as the cohesion of tablets, agglomeration of powders, and adherence of coatings. Key features Your benefits ● Wide operating range ➤ Suitable for any product or application ● Aw Quick mode ➤ Results in 4…6 minutes ● High measurement precision ➤ Reliable data every time ● Long term stability ➤ Reduced maintenance and calibration ● Interchangeable measurement stations ➤ Simple calibration and maintenance ● Multi channel display units ➤ 1 to 4 simultaneous measurements ● Validated PC analysis software ➤ Secure data acquisition and data handling Section contents HygroLab Laboratory Display Units/Analyzers ● ● ● ● ● Digital technology Multiple probes inputs Networkable Validated, easy to use software Integrated AW Quick function HygroPalm AW Portable Analyzers ● ● ● 85 Digital technology Integrated AW Quick function Measurement sets HygroClip water activity stations and probes ● ● ● ● ● 86-87 Wide range of measurement options to suit any application Digital calibration 100% interchangeable without adjustment Accessories for Water Activity measurement 88 Sample holders Disposable sample containers Water Activity Theory and reference, Technical Data ● ● 80 84 What is water activity? Water activity or moisture content? 89-91 Water Activity Applications W A T E R A Food industry – cheese Building materials Tobacco industry Bakery products Food industry – meat products C T I V I T Y Pet food – it’s important our best friends eat well! Pharmaceutical industry; tablet and powder ERH Paper manufacturing, converting, storing and printing Horticulture – seeds – prevention of germination during storage 81 W Introducing Water Activity Products A T E R A C T I The ROTRONIC range of water activity instruments uses the latest digital technology to introduce new levels of measurement performance, application flexibility and new features. Multiple probe inputs, PC based data handling, instrument networking, software based calibration, and interchangeable measurement stations are just some of the features included in our latest instruments. The humidity sensors used in our measurement probes have an enviable reputation for precision and reliability. Their performance is now augmented by software based analysis modes and new developments in mechanical probe design. These combine to achieve consistently high levels of performance with significantly reduced sampling times, and extremely cost effective pricing. Our range of water activity measurement stations and probes feature the HygroClip digital signal processing technology, including signal transmission and calibration. This produces a significant gain in accuracy, data integrity and stability, as well as convenient features such as simplified PC based configuration, data acquisition and calibration using easy-to-use Windows software. Bench top display instrumentation is also now complemented by a handheld portable solution; using the same high precision measurement technology to ensure consistently precise results and full interchangeability between laboratory and production data. V I T Y HygroLab HygroLab is a range of three high quality benchtop display instruments for the laboratory environment. HygroLab 1 is a cost effective 2 channel instrument with measurements displayed in %RH and °C units. HygroLab 2 has 4 probe inputs plus the option to display measurements in aw units, and an RS232 interface for display, data acquisition or configuration. HygroLab 3 is the flagship of our range, with all the features of the HygroLab 2, plus the addition of Aw Quick which has specialized features specific to water activity analysis including rapid equilibrium in typically 5 minutes or less, plus automatic capture of final values. HygroPalm AW1 In some instances, the ability to measure water activity in production or storage environments can be very useful. For example, when bulk deliveries are received, they can be checked on receipt to make sure that supply specifications are met. The new HygroPalm AW1 has been specially configured to offer the key functions of the HygroLab 3, including Aw Quick in a portable package, but without RS232 interface. Aw Quick Aw Quick is advanced software for water activity analysis which is either integrated within the HygroLab 3 or HygroPalm AW1 display instruments, or can be run on a PC connected to a HygroLab. AW Quick provides the user with final measurement results in typically five minutes or less, or can run a conventional water activity analysis with automatic detection and capture of equilibrium values. 82 HygroLab W A HygroLab Feature Overview T E R A C LC Display: Includes probe input indicator, three line numeric display with trend indicator Multiple inputs: 4 probes simultaneously T I V ENTER: Confirms selection I T Y MENU: Press this key to activate the functions menu Latched sealing ensures firm closure of the sample holder Probe for paste-like and solid products ON / Off key Up to 32 HygroLab 2 + 3 instruments can be networked together. 128 measurement probes controlled by one PC! Penetration probe for bulk goods UP/DOWN: Switches probes to be displayed & provides menu navigation. 83 HygroLab W A T HygroLab 1: E Basic two-probe bench top indicator of %RH and °C. R Key features: A • Accepts 2 ROTRONIC digital or analog probes • Display of % relative humidity and temperature • Software-based probe calibration (1-point or multi-point) C T Order code: HygroLab 1 I V I HygroLab 2: T Bench-top display instrument with four probe inputs, display in Aw units, %RH and °C. Ideally suited for climatic cabinets Y Key features: • • • • • • • • Accepts 4 ROTRONIC digital or analog probes Full psychrometric calculations Software-based probe calibration (1-point or multi-point) Can use one of the four probes as a reference to perform a 1-point adjustment of the other probes RS232 interface for PC running HW3 software RS485 interface for networking instruments together Optional analog outputs Optional: Accelerated water activity measurement with up to 4 probes (AwQuick mode): allows the measurement of most products in typically 5 minutes; requires HW3 software Order code: HygroLab 2 HygroDATA Lab HygroData Quick: Software HW3 and RS232 cable Aw Quick function HygroLab 3 Water activity analyzer with four probe inputs and integrated AW Quick. Key features: • Accelerated water activity measurement with up to 4 probes: (AwQuick mode): allows the measurement of most products in typically 5 minutes • Full equilibration measurement with up to 4 probes (Standard mode) with automatic detection of equilibrium conditions • Accepts 4 ROTRONIC digital or analog probes • Full psychrometric calculations • Software-based probe calibration (single-point or multi-point) • Can use one of the four probes as a reference to make a 1-point adjustment of the other probes • RS232 interface for PC running HW3 software • RS485 interface for networking instruments together • Audible signal when measurement is terminated Order code: HygroLab 3 HW3 Software The HW3 software package has a comprehensive range of functions which are compatible with the HygroLab. Order code: HygroDATA Lab Software HW3 and RS232 cable See chapter HW3 Software for full information. 84 HygroPalm AW1 W A HygroPalm AW1 T The HygroPalm AW1 is a portable instrument specifically configured for the measurement of water activity. It includes many of the advanced features of the HygroLab, including the AW Quick mode for results in 4 - 6 minutes. This makes it perfectly suited for users who wish to perform water activity analysis in production, goods receiving or storage areas where portable instrumentation is more convenient. A Key features: C • Accelerated water activity measurement: (AW Quick mode): allows the measurement of most products in typically 5 minutes • Full equilibration measurement (Standard mode) with automatic detection of equilibrium conditions • Single digital probe input • Single or multiple point digital calibration directly with the keypad • Aw display units • Available as a set with carry case • Optional docking station for battery charging or mains operation T Order code: HygroPalm AW1 PalmDock ACA E R I V I T Y Docking Station for AW1 with connector for AC1207 power adaptor Power adaptor HygroPalm AW1 Sets For on-site measurements, or for the first time user, the HygroPalm AW1 sets are a perfect solution. The sets are supplied in a lightweight but tough ABS carry case, and include all the items required to perform measurements and maintain the instrument. The difference between the two sets is the size of the sample holder and sample containers. AW1-Set-14 includes the WP-14/PS-14 for sample sizes such as tablets, powders, seeds, powdered spices, tea etc. AW1-Set/40 includes the WP-40/PS-40 for larger samples such as pet food, ore, nuts, beans, etc. (see also “Accessories & Consumables” for more information) Order Information HygroPalm AW1-Set-14 HygroPalm AW1-Set-40 Description HygroPalm AW1 HygroPalm AW1 Handheld display instrument AW-DIO WP-14 PS-14 EA35 EA80 AC1119 AW-DIO WP-40 PS-40 EA35 EA80 AC1119 Measurement probe Sample holder Sample container 35 %RH Calibration standards 80 %RH Calibration standards Carrying case 85 W Water Activity Probes A T Based on HygroClip digital electronics technology for high performance and convenient digital calibration, our selection of probes will suit almost any application. All water activity stations and probes incorporate temperature measurement as standard. E R AW-DIO Water Activity Station A C T I V I T Y The AW-DIO is a water activity measurement station which measures over the range 0…1 aw (0…100 %RH) and provides a digital output signal to interface with HygroLab and HygroPalm AW1 display units. Digital calibration can be performed using the display instrument. Minimized internal volume of the sensor chamber ensures fast equilibrium with all products, and an all metal construction ensures good temperature stability during measurements, with stainless steel used on all critical surfaces. Sample holders, sample containers and a sealing mechanism are detailed in accessories. AW-DIO is now the single option for water activity measurements in a sample chamber. It replaces previous products such as the WA-14, WA40, AS-ST, and WAO. It also has superseded the AWVC model with integrated air circulation fan. Through our continuous research and development program we have been able to match or improve the equilibrium performance of the ventilated system with our new Aw specific sensor, and upgraded mechanical design. Measuring range: Signal types: 0...100 %RH (0...1 aw), 5...50 °C ROV Analog signal, DIO Digital signal Order code: AW-DIO Dimensions of AW-DIO probe Temperature Control Stable temperature during measurements can be very important with some products in order to obtain precise results. Our measurement probes are designed with a high thermal mass to prevent variations during measurement, but for the highest precision or where laboratory temperature changes, temperature control solutions are available. Please contact ROTRONIC or your local distributor for more information. 86 Wate r Activity Probes W A HygroClip SP05 Insertion Probe For direct measurement of water activity in bulk samples. Applications include tablets, gel capsules, grain and plastic granules. HygroClip SP05 features a precisely engineered 5 mm diameter stainless steel probe with laser cut slots to allow the humidity measurement sensor exposure to water vapor in the air (not suitable for powders or dusty products). Measuring range: Accuracy: Signal types: 0...100 %RH (0...1 aw), -40...85 °C ±1.5 %RH / 0.015 aw, ±0.3K ROV Analog signal, DIO Digital signal Order code: HygroClip SP05-B5 5 mm insertion probe, Binder 5-pin connector T E R A C T I V I T Y HygroClip HP28 Insertion Probe For direct measurement of water activity in bulk samples. Applications include powders, granules, grain and cereals. HygroClip HP28 features a robust 10 mm diameter stainless steel probe with replaceable sintered steel dust filter to allow the humidity measurement sensor exposure to water vapor in the air or product. Measuring range: Accuracy: Signal type: 0...100 %RH (0...1 aw), -40...85 °C ±1.5 %RH / 0.015 aw, ±0.3K ROV Analog signal, DIO Digital signal Order code: HygroClip HP28-B5 10 mm insertion probe HygroClip SC04 /SC05 Suitable for air measurement in small spaces thanks to the 5 mm probe diameter and compact dimensions. For customers measuring water activity, the HygroClip SC05 is useful for the measurement of humidity and temperature in packaging, storage containers and incubators. Measuring range: Accuracy: Signal types: Recommended application range: Order code: HygroClip SC04 HygroClip SC05 MOK-02-B5 0...100 %RH (0...1 aw), -40...100 °C ±1.5 %RH / 0.015 aw, ±0.3K ROV Analog signal, DIO Digital signal -40...40 °C: 0...99 %RH / 40...100 °C: 0...70 %RH 4 mm cable mounted probe 5 mm cable mounted probe Cable, HygroClip SC04 / SC05 to HygroLab/HygroPalm AW1 87 W Accessories and Consumables A T E R A C T I V I T Y Sample Holders Stainless steel sample holders that are precisely engineered to work with the AW/DIO water activity chamber. Two sizes are available, WP14 is for small product samples (14 mm depth) and WP40 for larger materials (40 mm depth). Both products provide excellent sample containment and optimum temperature stability. WP-40TH has an integrated water jacket for temperature control. Recommended temperature control level max. ±5 °C from ambient temperature. Material: WP14 and WP-40: V2A Steel, WP-40-TH: Brass, nickel coated. Order code: WP-14 WP-40 WP-40TH for PS14 for PS14 and PS40 with water jacket for temperature control approx. 350 g approx. 1250 g approx. 1550 g Sample Containers Disposable sample containers that ensure the optimum sample volume is introduced into the WP-14 and WP-40. They help to prevent the sample holders from coming into direct contact with product being tested, and hence prevent soiling or cross contamination. The sample containers also provide a convenient means of collecting and storing samples. Order code: PS-14 PS-40 Pack 100 sample containers 14 mm deep to suit WP-14-S Pack 100 sample containers 40mm deep to suit WP-40 approx. 880 g approx. 1250 g Clamp Sealing Mechanism In some circumstances additional mechanical sealing of the AW measurement station and sample holder is required to prevent external conditions influencing the sample. The AW-KHS provides a strong mechanical seal (Only in combination with WP-40 and WP-40TH). Order code: AW-KHS approx. 1100 g Humidity Standards The ROTRONIC SCS certified humidity standards provide a reference value against which instruments can be calibrated. They are supplied in packs of 5, complete with certificates of calibration. They can be applied to all probe types, with Water Activity probes using sample holders and containers, for other probes (HygroClip SP05, SC04 and HP28) a calibration device is required. Order code: EA-xx-SCS Where xx = 0.5, 05, 10, 11, 20, 35, 50, 65, 75, 80 & 95 %RH approx. 32 g Calibration Devices Provide a sealed environment around probes where ROTRONIC humidity standards can be applied. Order code: ER-05 ER-15 EGL for 5 mm diameter probes (HygroClip-SP05 / SC05) for 15 mm diameter probes (HygroClip S) for 10 mm diameter probes (HygroClip HP28) AW-DIO can be calibrated in combination with the sample holder and container (WP-14/PS14). 88 Water Activity Explained W A What is Water Activity? T Water Activity (aw) is the relative humidity which is reached at equilibrium in a sealed container in which a hygroscopic product has been placed, but expressed on a scale of 0…1. Water Activity measurement is most commonly used in the food industry, where it is used to determine shelf life and quality. R What is Equilibrium Relative Humidity? A Equilibrium Relative Humidity (ERH) is the value of relative humidity into which a Hygroscopic product can be placed where no net exchange of moisture between the product and the surrounding environment can take place. It is expressed on a scale of 0…100%. ERH is typically used in the paper and pharmaceutical industries, but can be applied to almost any product that is sensitive to moisture, or where the presence of moisture can effect product handling. C E T I V Water Activity or ERH? Both aw and ERH are an expression of the amount of free water vapor present on a product, both at its surface and within its structure, and are practically the same measurement expressed in a slightly different way. Throughout this document we will refer to Water Activity, but this can be interchanged with ERH. Where specified, ROTRONIC products offer the user the possibility to select display units of aw or %RH. I T Y What is Moisture Content? Moisture content, when referring to a solid material, is an expression of the percentage of the material’s weight which is water (both in liquid or gaseous phase); usually referred to as ‘percent moisture content’. This term is widely used in many areas of industry. Correlation between Water Activity and Moisture Content The correlation between Water Activity and Moisture Content can be related by a graph called a Sorption Isotherm (see diagram). Due to the complexity of the sorption processes, the isotherms cannot be computed but only be determined experimentally. Each Isotherm is valid for one specific product at one particular temperature only. Why is Water Activity measured? Water Activity is an important parameter in the food and pharmaceutical industries. It represents the mass of free water within a product, which is of fundamental importance for many enzymatic reactions and especially for the growth of micro-organisms. The water within a product such as food is bound by various ingredients such as proteins, salt or sugar. This chemically bound water is not available for the micro-organisms, and hence they cannot replicate. The higher the amount of water-binding ingredients in a product is, the less water can evaporate. Therefore, the water vapor pressure over the product is in direct correlation to the amount of water that is available for the micro organisms. Water activity has an important influence on product stability (e.g. microbiological stability, flavor retention), handling properties such as the agglomeration of powders, chemical stability and physical properties such as dimensions of paper. Water Activity measurement offers a non-destructive, easy-to-use measurement in a wide range of convenient configurations for both laboratory and on-site use. 89 Schematics and Diagrams W A T E R Networking (HygroLab 2 and 3) Optional HW3 software offers a simple means of quickly establishing a PC based network. Up to 32 HygroLab indicators and/or HygroFlex transmitters can be connected together on a network. Any instrument can be used either as a slave or a master, without special configuration. Each unit must be given a unique network address with the HW3 software (0 to 31). The master is automatically the unit that is connected to the COM port of the PC by means of the RS232 port. See Connectors – RS232 / RS485 for details. A Adr. 0 C Adr. 1 Adr. 2 Adr. 31 T I V I T Y RS232 (3 wires) max. 12 m RS485 (2 wires) max. 1000 m Dimensional diagrams WP-14 WP-40 ~160 ~220 200 x 120 WP-40TH 90 AW-KHS Technical data W A Aw Quick Function T Higher productivity in the laboratory and greater application flexibility at lower cost per measurement. E R Aw Quick is a software tool developed by ROTRONIC for the fast determination of water activity. The average measurement time can be reduced to roughly five minutes when 4 probes are used simultaneously. A C HygroLab 3 incorporates this feature. The function can be called directly from the keypad or be controlled from a PC. For HygroLab 2, the feature is only available as a PC-option, which can be retrofitted. T I V Easy and efficient operation: the functions are selectable with a mouse click. As soon as the measurement value is underlined with a green bar, the measurement is terminated. I T Y Technical Data HygroLab 1, 2, 3 and HygroPalm AW1 Key Features Probe connections PC Interface Networking Aw Quick mode Calibration functions with keypad 1 point %RH (aw), 4 point %RH (aw), 2 point °C/F Calibration functions using PC and HW3 1 point %RH (aw) 4 point %RH (aw), 2 point °C/F Display units Calculated parameters Audible signal at measurement end: Instrument operating range Display Type Trend indicator Display resolution Housing Power supply Power consumption CE conformity Weight HygroLab 1 2 No No No Yes No No No No %RH, °C, °F, None HygroLab 2 HygroLab 3 4 4 RS232/485 Up to 32 instruments using RS485 Option. Via PC with Integrated & with HygroData Quick PC and HW3 Software Software and data cable) Yes Yes Yes Yes %RH, aw, °C,°F, calculated parameters Dew point, wet bulb, enthalpy, mixing ratio, moisture content, partial water vapor pressure, saturation water vapor pressure No No 0…99 %RH, -10…60 °C (14…140 °F) Liquid Crystal 3 line alphanumeric No Yes 0.1 %RH/0.1 °C/F 0.1 %RH/0.1 °C/F, 0.001 aw Aluminum, 220 x 170 x 55 mm 9 V Power adapter, +tip max. 20 mA EN 61000-6-2:2001, EN61000-6-4:2001 1100 g HygroPalm AW 1 1 No No Integrated No No aw, °C, °F, None Yes No 0.1 %RH/0.1 °C/F, 0.01 calculated value 0.001 aw ABS 9 V battery 300 g Note: Many older products have been replaced by new ones, that perform better. ROTRONIC will continue to support the old products as long as possible. Our customers are used to the fact that we still maintain probes and instruments that are over 20 years old. We will continue this tradition for the benefit of our customers who will thus always get the best price / performance ratio and have their investments secured. 91 T E M P E R Temperature Measuring Instruments Temperature Measuring Instruments T1 and TI1 series The measurement of temperature is essential in many production, storage and transportation applications. In many countries, the law demands that products for human consumption, such as food and drugs, are stored at specific temperatures, which must be controlled and recorded. ROTRONIC offers a range of handheld meters and fixed installation transmitters for temperature measurement. They are easy to use and simple to install, with a wide range of configurations and measurement ranges to make them suitable for most applications. The M-Series and Roline L series of transmitters detailed in the transmitter section of this catalog are also available in temperature only versions. A T U R E Handheld measuring instrument T1 for Pt100 probes • • • • • • • Measuring range: -100…500 °C Plug in Pt100 probes, see next page Automatic range adjustment at 200 °C Large, 3 1/2 digit LCD display DATA HOLD °C/°F selectable on PCB by jumper Adjustable Order code: T1 AC1115 Carry case Special Order: North American Market TI Transmitter for Pt100 probes • • • • • • Transmitter for the most demanding industrial processes IP65 housing Linear output signals Probe connector on housing Connectable Pt100 probes, see next page Optional digital display Order code: see table on page 95 Special Order: North American Market 92 Pt10 0 Probes Temperature Measurement Probes Probe Type Specification Material Connection AC1900 Rod type 100 x 3 mm -70...500 °C Pt100 Class A DIN1.4401 Binder 4pin plug Rod type 250 x 3 mm -70...500 °C Pt100 Class A DIN1.4401 Cable type 250 x 3 mm T max. cable: 80 °C -70...500 °C Pt100 Class A Cable type 200 x 6 mm Not waterproof -70...500 °C Pt100 Class A T max. cable: 110 °C DIN1.4401 AC1904 Cable type 50 x 6 mm Waterproof -50...110 °C Pt100 Class A T max. cable: 110 °C DIN1.4401 2m straight thermoplastic cable, Binder 4 pin plug AC1905 Surface type 40 x 10 x 5 mm -70...500 °C Pt100 Class A T max. cable: 180 °C DIN1.4301 2 m straight silicon cable, Binder 4 pin plug Surface type 90 ° bend, 200/60 x 4.5 mm 0...120 °C Pt100 Class B Do not calibrate in oil! T max. cable: 80 °C DIN1.4401 AC1908 Handheld type for measurement in air 250 x 4.5 mm -50...120 °C Pt100 Class A T max. cable: 80 °C DIN1.4401 1m PUR helix cable, Binder 4 pin Plug AC1909 Rod type for measurement in air 100 x 4.5 mm -50...120 °C Pt100 Class A DIN1.4401 Binder 4 pin Plug AC1910 Screw-in type 1 4 / ” G, 30 mm screw-in depth -70...500 °C Pt100 Class A T max. cable: 180 °C DIN1.4401 2 m straight silicon cable, Binder 4 pin Plug -70...500 °C Pt100 Class A T max. cable: 180 °C DIN1.4401 Screw-in type -70...500 °C DIN1.4401 / ” G, 100 mm screw-in depth Pt100 Class A T max. cable: 180 °C 1 4 AC1913 Foil type 26 x 32 x 2.5 mm -50...200 °C Pt100 Class B All probes are special order: North American Market A T 1m PUR helix cable, Binder 4 pin plug U R 2m straight thermoplastic cable, Binder 4 pin plug E 10 ø4.5 100 30 1m PUR helix cable, Binder 4 pin Plug 2 m straight silicon cable, Binder 4 pin Plug 30 50 30 50 30 50 1 m silicon cable, Binder 4 pin Plug ø3 1/4"G 60 x 5 200 x 5 L L 2 m silicon cable, straight, Binder 4 pin Plug Silicon 5 40 ø3 DIN1.4401 ø3 AC1912 Screw-in type 1 4 / ” G, 50 mm screw-in depth R Binder 4pin plug L 32 2.5 AC1911 E 1/4"G AC1907 P 1/4"G AC1903 M 25 AC1902 E Pt100 Probes Order Nr. AC1901 T 93 Accessories / Pt10 0 Temperature Sensors T E M P Accessories Order code: Description AC2001 Screw-in measuring sleeve for 3 mm probes; thread 1⁄4 “ G Immersion depth 50 mm AC2002 Screw-in measuring sleeve for 3 mm probes; thread 1⁄4 “ G Immersion depth 100 mm HygroClip TH100-B5 Adaptor for all Pt100 probes for HygroPalm 2/3 & HygroLab instruments with Binder 5-pin plug AC1607-2 AC1607-3 AC1607-5 Extension cable for Pt100 probes Binder 4 pin male/female plugs Extension cable for Pt100 probes Binder 4 pin male/female plugs Extension cable for Pt100 probes Binder 4 pin male/female plugs E R A T U R E 2m 3m 5m Special Order: North American Market Pt100 temperature sensors A Pt100 sensor changes its electrical resistance with temperature; its value is 100 Ohms at 0 °C. Changes are measured using a bridge circuit to generate a signal suitable for conversion to an output signal or displayed value. Like any manufactured object, a Pt100 sensor is subject to variations. Today, 5 accuracy classes are obtained by selection: Class B, Class A, 1/3 DIN, 1/5 DIN and 1/10 DIN. This corresponds to tolerances (at 0 °C) of ±0.3, ±0.15, ±0.1, ±0.06 and ±0.03 °C. The adjacent table illustrates this. Because of the expense of the selection process, a 1/10 DIN Pt100 sensor is more expensive than 1/3 DIN version. As Pt100 measurement errors increase with temperature, adjustment of the measurement circuit close to the working temperature ensures that good results can be obtained with the more cost effective Pt100 grades. This procedure should not be used for portable Pt100 measuring instruments where wide temperature variations can occur. Another way of improving measurement accuracy is to use 3- or 4-wire connection, which eliminates additional errors due to connecting cable resistance. ROTRONIC exclusively use platinum Pt100 sensors for temperature measurement within combined humidity/temperature probes. Temperature and humidity sensors should be matched to one another to provide accurate results. 94 Class B Temp +/+/°C °C Ω -200 1.3 0.56 -100 0.8 0.32 0 0.3 0.12 100 0.8 0.30 200 1.3 0.48 300 1.8 0.64 400 2.3 0.79 500 2.8 0.93 600 3.3 1.06 650 3.6 1.13 Tolerance Class A 1/3 DIN +/+/+/+/°C Ω °C Ω 0.55 0.24 0.44 0.19 0.35 0.14 0.27 0.11 0.15 0.06 0.10 0.04 0.35 0.13 0.27 0.10 0.55 0.20 0.44 0.16 0.75 0.27 0.60 0.21 0.95 0.33 0.77 0.26 1.15 0.38 0.94 0.31 1.35 0.43 1.10 0.35 1.45 0.46 1.20 0.38 1/5 DIN +/+/°C Ω 0.26 0.11 0.16 0.06 0.06 0.02 0.16 0.05 0.26 0.10 0.36 0.13 0.46 0.16 0.56 0.19 0.66 0.21 0.72 0.23 1/10 DIN +/+/°C Ω 0.13 0.06 0.08 0.03 0.03 0.01 0.08 0.03 0.13 0.05 0.18 0.06 0.23 0.08 0.28 0.09 0.33 0.10 0.36 0.11 Temperature Transmitters T E Order Code TI temperature transmitters Order code Example: Transmitter series Power supply: Output signal Cable connection Display Temperature range = Output signal 1 2 TI1 TI1 230 VAC 115 VAC 4…20mA loop power (Umin =10 V+0.02 x load) 24 VAC galvanically separated 10(15)…35 VDC/12…24 VAC PT100 connector Binder 4-pin 0…20 mA 4…20 mA 0…1 V 0…5 V 0…10 V 1 M16, Terminals 2 M12, Terminals Tuchel plug 7-pin None With Display 0… 50 °C - 30… 70 °C 0…100 °C - 40… 60 °C 0…200 °C - 50…150 °C -100…100 °C -100…200 °C -100…300 °C 3 2 4 - 5 B 6 4 7 - 8 4 9 10 11 12 13 14 A 1 X - 1 4 0 1 2 3 8 M P E R A B 4 0 4 1 5 0 T A A V V V U R 1 2 7 E X D 1 1 1 1 2 2 2 2 2 0 1 4 9 0 1 2 3 4 Special Order: North American Market Some transmitters of the M1 and Roline L-series are available as temperature only transmitters. See pages 52 to 53 Technical data temperature measuring instruments T1 Handheld IP50 9 V PP3 alkaline battery 340 hrs. TI1-series Transmitter IP65 AC/DC/mains supply N/A N/A N/A N/A ≤ 32 mA ≤ 20 mA ≤ 22 mA N/A N/A N/A 1 3-wire 0…50 °C0…90 %RH -100…500 °C ±0.1 K 0.1 K 0.1 K/year Yes Yes Yes Yes 240 g < 500 Ω >1000 Ω Option 80 108 50 120 Series Instrument Type Protection rating Power supply Battery life max. Power consumption 3-wire current output signal 2-wire current output signal 3-wire voltage output signal Load Current output signal Voltage output signal Galvanic isolation Number of probe inputs Probe connection type Operating range (electronics) Measuring range with Pt100 Accuracy at 23 °C Reproducibility Long term stability Display 3 1/2 Digits Auto power off function Battery indicator Hold Function Weight -20…50 °C /0…100 %RH Probe dependent ±0.3 K 0.1 K Option, not for 2-wire types N/A N/A N/A 400 g TI-series Industrial transmitter Wall mount and cable type 95 O E M P OEM Original Equipment Manufacturers (OEM) require individual solutions to suit the needs of their customers. ROTRONIC has been producing customized humidity measurement products to suit the OEM market for many years, and has a wide breadth of experience in satisfying this specialist need. Today, our OEM capability is greater than ever, from the simplest sensor supply, right through to complex transmitters for the industrial process market. The HygroClip probes in particular are sought for by OEM customers. Thanks to their compact dimensions and accuracy at a very reasonable price they are very often the product of choice. R O D U C T S OEM customer requirements and final applications vary widely, so the need for an experienced and flexible supplier is key. As each project is different, our experienced sales team will discuss project objectives, technical requirements and target costs at an early stage. We will then formulate an initial proposal based on these discussions and submit this to the customer. After agreeing a final specification, samples can then be submitted for technical approval and testing. During this phase, ROTRONIC is able to participate in the customer assessment of product suitability, and if required, provide secondary testing of the completed assembly in our own accredited test facilities. We are also able to advise on the final assembly and calibration process. Wherever possible, we will utilize existing products or sub assemblies in the creation of an OEM solution. This can provide significant advantages in design and development costs, as well as reducing production start up time. ROTRONIC OEM Product Capability • • • • • HygroClip probes %RH sensors Calibrated sensor modules Transmitter or probe sub-assemblies Standard ROTRONIC products with customer’s own branding OEM Applications and Advantages The availability of digital and analog output signals and the wide supply voltage range of 3.5 to 24 VDC makes the HygroClip suitable for a wide variety of applications. The application range of 0…100 %RH and -40 to 85 °C is unique. ROTRONIC is capable of manufacturing customized types according to your requirements. The HygroClip is ideally suited as an integral part of complete humidity and temperature measurement systems, such as: display and handheld instruments, incubators and environmental chambers, process control applications, multi channel data loggers, high precision climate control, electronic cabinets, EDP applications, fermentation chambers, gas detection systems and portable instrumentation, air conditioned containers and many others. ROTRONIC OEM Support Capability • • • • • • • • 96 Custom design Custom packaging Labelling and barcodes Documentation, including manuals CAD drawings for manufacturing records Calibration materials and systems Calibration seminars for OEM customers Training of customer technical and sales staff OEM Humidity Sensors In many high volume applications, the supply of only the %RH sensor is a cost effective option. In these circumstances the OEM should carefully consider the process of calibrating the final measurement circuit to obtain the required performance. When calculating the actual cost of the implementation of humidity measurement, the sensor cost must include provision of the calibration process, circuit design and final assembly. In many cases, the specification of a pre-calibrated measurement module can be equally cost effective, and can reduce the ongoing costs of production. ROTRONIC can supply a range of %RH sensors based on capacitive technology. Various standard products are available with pre-defined specifications, dimensions and characteristics. We are also able to offer customized sensor production to suit specific project requirements. O E M P R O D U C T S Calibrated %RH Sensor Modules The advantage of implementing a pre-calibrated sensor module is that the OEM does not have to develop a measurement circuit or an in-house calibration system. The appropriate product can be specified to be compatible with existing interface and power supply requirements, and with simple connection to the final application prior to delivery. The whole specification, design and supply of the humidity measurement element of the OEM need can be handled by ROTRONIC, leaving the customer to focus on their core product development and support. ROTRONIC in-house calibration procedures have been developed over many years, and proven in many thousands of instances. The end result for the OEM customer is a well developed production process that assures best possible measurement performance with zero investment. Humidity Transmitter or Probe Sub-Assemblies For OEM customers who offer their own branded range of %RH sensors, for end uses such as HVAC/BMS, process control or data acquisition, ROTRONIC can supply a completed and calibrated product to fit the customers own housings. In these circumstances, the customer has two main advantages. The responsibility for product design, assembly and calibration is handled by ROTRONIC, which minimizes production costs and component stock risk. The customer also benefits from an ‘own brand’ product which has the very best performance capability, and has access to ongoing development to keep the product at the leading edge of the humidity market. Standard Products with Customers Own Branding Throughout the pages of this catalog you will find a range of humidity measurement products that are market leading in terms of performance, features and price. ROTRONIC is happy to effect a simple ‘re-brand’ of the standard product range so that the OEM can offer a class leading product with no development cost and minimal stock risk. Ancillary products such as calibration materials, replacement filter elements and software are of course already available. Support documentation such as manuals, software validation, type approvals and drawings can be easily re-branded on behalf of the OEM customer. 97 Example OEM Products O E M The products described are standard OEM products which are mass produced in different quantities for many existing customers. They are available on very short delivery times, often from stock, and require no further development or documentation. Full technical datasheets are available in standard formats and show full technical and mechanical specifications. The range of products shown is by no means definitive. If you need a customized product, we shall be pleased to quote you, based on a requirement specification. Please do contact us for further information. P CS %RH sensor R The CS %RH sensor is a substrate based capacitive %RH sensor. It is designed specifically for applications where high quality is as important as cost. Two standard versions are available to suit most applications. O D Features overview: • • • • • • • U C T S Wide operating range Chemically resistant Good long term stability Fast response times Low hysteresis Compact dimension and high sensitivity (CS10) Fast response and solvent resistant (CS30) Technical Data Humidity measuring range Temperature operating range Typical capacitance at 30 %RH and 23 °C Typical sensitivity (15 ... 95 %RH) Linearity at 23°C Hysteresis Response time t90 Frequency range Electrical range, signal form Connections CS10 0...100 %RH -30...150 °C 140 pF ±40 pF 0.4 pF / %RH ± 1.5 %RH (20...90 %RH) < 1.5 %RH <12 sec 1...70 kHz AC ±12 V, no DC SIL CS30 0...100 %RH -40...190 °C 300 pF ±40 pF 0.45 pF / %RH ±2.0 %RH (20...95 %RH < 2.0 %RH <10 sec 1...100 kHz HygroClip S / S3 • • • • • • 100 % interchangeable 1 digital and 2 analog outputs ROTRONIC Hygromer humidity sensor 0...100 %RH Accuracy ±1.5 %RH /0.3 K (at 23 ±5 °C) Long term stability better than 1 %RH/year High precision Pt100 1/3 DIN temperature sensor Order code: HygroClip S HygroClip S3 Black White -40...85°C = -0.4...0.85V -40...60°C = 0...1V HygroClip technical data and order information Voltage supply / current consumption Operating range Accuracy at 23 ± 5 °C Output signals HygroClip S HygroClip S3 Digital output signal Start up time Resolution %RH / °C Adjustment Humidity sensor / temperature sensor Output load Cable length for DIO signal Sensor protection Dimensions with MOC Type of enclosure Color (HygroClip S) (HygroClip S3) 98 3.5...24 VDC / approx. 4 mA Humidity / temperature 0...100 %RH / -40...85 °C Humidity / temperature ±1 %RH / ±0.3 K Humidity / temperature 0...100 %RH = 0...1V / -40...85 °C = -0.4...0.85 V Humidity / temperature 0...100 %RH = 0...1V / -40...60 °C = 0...1 V One wire DIO 2.7 s first measurement; 0.7 s subsequent Analog: 0.02 %RH, 0.06 °C / Digital: 0.004 %RH, 0.004 °C By PC / software or handheld instrument (EE-Prom) Hygromer® AC-1 / Pt100 1/3 DIN >10 kOhm max. 5m Wire mesh filter (max. 20m/s) 100 x 15 mm IP65 / NEMA4 Anthracite RAL 7016 PC Novarex white 7022Nr. 312043; corresponds to RAL 9010 Example OEM Products H290 Transmitter sub-assembly H290 is an OEM humidity and temperature product with an impressive specification. It is particularly well suited to applications such as climatic chambers and drying systems. It is available either as a pcb and probe combination for fitting into the customer’s own enclosures or housings, and can also be supplied in an industry standard IP65 case. H290 provides a linear analog output of 4...20 mA or 0...10 V from a power supply of 10...35 VDC or 12...24 VAC. In addition, it can be produced with the digital DIO signal. Temperature measurement is by direct connection to a Pt100 or thermistor, depending on the customer’s requirements. Also featured on the H290 is a compensation system for operation over a wide -50...200 °C range, with integrated cable length compensation. This means that whatever the measurement temperature, or the differential in temperature between sensors and electronics, optimum results will be obtained. O E M P R O D U C T S THT Series A range of humidity transmitters with excellent stability and very cost effective pricing. The THT series offers a range of analog outputs such as 4...20 mA and 0...10 Volt, for both humidity and temperature. There is also as the option to connect directly a temperature sensor such as Pt100 or thermistor. THT is highly suitable for close control applications such as air conditioning or building monitoring where steady state conditions are usual. OEM-HUM-2W-2 This low cost 2-wire loop powered transmitter features a 4...20 mA output signal for 20...100 %RH, with measurement accuracy of ±5%RH. It accepts supply voltages between 9...28 VDC and can operate over a temperature range of -10...60 °C; Roline L-Series Our standard low cost transmitter is particularly well suited to OEM application thanks to its excellent combination of performance and price. It has a wide choice of measurement ranges and output signals, and its compact printed circuit board dimensions means that it can be easily integrated or reconfigured into existing housings. It may also be customer branded. Further details see pages 60...62 10786 Series A 2 x 2-wire transmitter for 4...20 mA signals, operating in combination with a connected HygroClip probe. The 10786 and HygroClip probe must be adjusted at the same time using the on-board digital interface to provide optimum accuracy of the output signal. 10797 Series The 10797-Series is available either as humidity transmitter only, or as combined humidity / temperature device with an operating range of -30...70 °C. 0...20 or 4...20 mA output signals can be chosen. For full technical specifications, dimensions, and specific product features, please request the individual datasheets. 99 Introduction C A L I ROTRONIC instruments have excellent long term stability characteristics, with better than ±1 %RH stability over a year in normal conditions, but we still recommend that regular calibration checks are performed (once per year typically). Normal conditions can be defined when high temperature or humidity, or MAC (Maximum Allowable Concentration) levels of chemical pollutants are not normally experienced in the environment being measured. Many company operating procedures call for calibrations more frequently, depending on internal quality assurance systems. B R A T I Why is calibration essential? Today, many companies are working to ISO 9000 standards and are obliged to calibrate their measuring equipment on a regular basis. Regulators such as the FDA (Food and Drug Administration in the USA), EMEA, Swissmedic etc. demand that the devices are calibrated and traceable to National Standards. Last but not least, the quality standards defined by each company specify the best possible accuracy and proof of traceability. Hence, it is in the interest of the user to have equipment calibrated and adjusted in order to maintain optimum performance. Rotronic offers calibration devices and accessories for all probes we probes we produce as well as by other manufacturers. Please contact us for guidance on the most appropriate calibration device and humidity standards. O N Accredited Calibration Laboratory for humidity and temperature SCS 065 ROTRONIC maintains a calibration laboratory which is accredited by the Swiss METAS (Metrology and Accreditation Switzerland) for the parameters relative humidity and temperature. We can offer calibration services and Swiss Calibration Service certificates that are traceable to the National Standard. Accreditations and certificates are mutually acknowledged by most national organizations. Section contains Humidity standards and certificates ● ● ● ● Long shelf life – up to 10 years Precise and easy to handle Ready for use – no solution preparation Sample calibration certificates for the standards Calibration devices ● ● ● 101 Easy to use Robust Optimized chamber volume Calibration by PC ● ● 101 Calibration with HygroLab Calibration with MOK-WIN calibration interface cable Temperature calibration ● ● 103 Temperature calibration in Fluorine-Inert SCS certificates for -25...125 °C Humidity generators ● ● HygroGen – Portable generator for reference climate FG431 - Multiple generator for reference climate ROTRONIC or subsidiaries and some ROTRONIC distributors offer calibration seminars for their customers. Ask your distributor or Rotronic subsidiary for further information. 100 101 104 Humidity Standards and Certificates A SCS* humidity standards The humidity standards from ROTRONIC are delivered in boxes of five sealed ampoules of the same humidity value. Each ampoule is marked with the %RH value and a serial number. The most frequently used values are 35 and 80 %RH, which are used to perform a 2-point calibration. All ampoules contain a non-saturated salt solution, apart from the 0 %RH standard, which uses a highly porous ceramic material (molecular sieve). The standards are subject to tests, performed by high precision dew point mirrors. An SCS certificate stating the traceability and uncertainty of the humidity standard is enclosed with every pack. The National Metrology Standards world-wide regularly carry out calibration inter-comparisons to ensure their standards are comparable. As a result there is now a Mutual Recognition (ILAC) Agreement, and standards from the participating countries are accepted world-wide. Humidity value 0.5 %RH 5.0 %RH 10.0 %RH 11.3 %RH 20.0 %RH 35.0 %RH 50.0 %RH 65.0 %RH 75.3 %RH 80.0 %RH 95.0 %RH L I B R A T I Order information humidity standards Order code EA00 EA05 EA10 EA11 EA20 SCS EA35 EA50 EA65 EA75 EA80 EA95 C Uncertainty at 23 ± 2°C ± 0.1 %RH ± 0.1 %RH ± 0.3 %RH ± 0.3 %RH ± 0.3 %RH ± 0.5 %RH ± 0.9 %RH ± 0.9 %RH ± 0.9 %RH ± 1.2 %RH ± 1.2 %RH O N DPH 911 Reference dew point mirror for SCS certification of RH standards. Calibration Devices The ROTRONIC calibration devices are small, airtight chambers that fit exactly to the respective probes. The lower part is a screw-on lid, into which the humidity standard is added on to a textile pad. After a period of stabilization, typically 60 minutes at stable temperature, the required humidity value is attained. The instrument can then be calibrated against the humidity reference value. Calibration devices are available for the entire range of ROTRONIC products, and we can also supply calibration devices for third party probes. Ask us for custom products. The detailed list of all available calibration devices may be found in the Accessories section, page 117. Electronic calibration with HygroLab 2 & 3 and MOK-WIN With a bench top instrument HygroLab 2 or HygroLab 3, up to four probes can be calibrated simultaneously via the keypad. When the instruments are connected to a PC, calibrations can be done even easier and faster using HW4 software. A few mouse clicks will do! The HygroLab instruments can be used for calibration of all digital HygroClip probes. Depending on the probe type, an adaptor cable should be used. The system prints calibration certificates on request - all you need to do is to click the mouse button! Order code: HygroLab 2 HygroLab 3 (4-probe inputs & psychrometric calculations) (4-probe inputs, psychrometric calculations, AW-Quick) Calibration with MOK-WIN calibration interface With the MOK-WIN calibration interface and the HW3 software single HygroClip S probes may be calibrated and adjusted directly from the PC. Order code: MOK-02-WIN HW3 calibration interface calibration software Details regarding MOK-WIN may be found in section Transmitters / HygroClip. * SCS = Swiss Calibration Service 101 Humidity Standards and Certificates C A L I B Do I need a factory adjustment certificate or an SCS*-certificate? Factory Adjustment Certificate All ROTRONIC probes are delivered with a factory adjustment certificate. The certificate shows the probe type and serial number, the ambient temperature, adjustment points, the date of calibration and the inspection equipment used. Format of certificates supplied within the North American market will be different from that shown. R A T I O N SCS * Certificate SCS certificates are demanded especially by the pharmaceutical, chemical and food industry. As an accredited calibration laboratory for relative humidity, we are capable of performing SCS calibrations at 23 °C with the best possible measurement uncertainty. ROTRONIC is accredited by METAS (Metrology and Accreditation Switzerland) with the number SCS 065. N.I.S.T traceable Certificate of Calibration provided upon request within the North American market. * SCS = Swiss Calibration Service 102 Calibration FG-431 calibrator uses a conditioned process air system developed by ROTRONIC. It enables the simultaneous calibration of four humidity probes of any kind with a maximum diameter of 25 mm. Four extremely stable humidity values are available. A calibration according to international rules (flow rate 10 l/min at 1 m/s air speed) is terminated after only 2 minutes. In order to perform traceable and reliable calibrations, special attention was given to the conditioning of the process air. The flow of the humid air can be adjusted by high precision needle valves over the entire range up to 99 %RH. Each outlet is equipped with a SCS-calibrated HygroClip, which controls the air stream. ROTRONIC digital probes can be directly adjusted via the serial interface. Various adaptors for probe diameters from 4 to 25 mm and for pcb-mounted sensors are available. The calibration system is designed for medium-size companies or calibration laboratories. It can be extended in master-slave mode. With a throughput of 1000 probes per year, the system cost is amortized within four years! Key features Your benefits ● Generates 4 reference climates simultaneously ➤ Rapid multi point calibration ● Integrated temperature adjustment ➤ Stable flow rates ● Large control range of the 3 controlled outputs ➤ Calibration over the entire humidity range ● Flow rate according to international norms ➤ Approved and reproducible values ● Short equilibrium time ➤ Ready and stable within 5 minutes C A L I B R A T I O N Technical data Functional principle Standard humidity values Control range 0 %RH 10 %RH 35 %RH 80 %RH Flow rate Air speed Principle of humidifier Principle of dryer Reference probes Accuracy of reference Stability Temperature of process air Reference display Testee display Interface Dimensions HxWxD Weight External resources Power supply Compressed air supply Water quality Order code: Conditioned process air for 4 air outlets 0 %RH, 10 %RH, 35 %RH, 80 %RH Fixed to 0.1 %RH 5...50 %RH 10...80 %RH 20...99 %RH 10 l/min for every outlet 1 m/s Heated humidifier columns Self-regenerating adsorption dryers with molecular sieve HygroClip S1 <1 %RH/ <0.2 K at standard values < 0.5 %RH at stable environment temperature Updated environmental temperature Humidity & temperature per outlet %RH/ °C for ROTRONIC digital probes %RH/ °C for analog probes RS232 for digital probes and reference 990x560x770 /1060 mm (with table) 140 kg 230 VAC / 2 A 6 bar, min. 50 l/min (uncompressed), with cold dryer 0 °C and oil separator De-ionised water, <1 µS FG-431 Special Order: North American Market Temperature Calibration in Fluorine-inert Bath The calibration of temperature is always a delicate task. ROTRONIC now offers SCS certificates for temperature calibration of combined humidity/temperature probes or temperature probes only. The wide temperature range is -25 to 125 °C. Accuracy is ±0.03 °C. Fluorine-inert is a liquid with a high boiling point that does not react with any material and is electrically isolating. Therefore, even humidity probes may be calibrated directly in the bath without being influenced. Order code: see price list. 103 M obile ROTRONIC Hu midity and Temperature Generator C A L HygroGen® is a mobile generator of controlled % relative humidity and temperature environments, designed to be used on-site to calibrate measurement equipment. It is a compact and self-contained unit. Of course, it is also suitable for customers who need to calibrate a number of probes using a simple and low cost instrument. Two models are available. I B R A T I O Key features Your benefits ● Generates a controlled reference environment ➤ Any value can be set ● Fully integrated temperature control ➤ Set your own stable temperature ● Suitable for all humidity/temperature probes ➤ Low costs ● Self-contained ➤ Requires mains power only ● Measurement chamber for max. 5 probes ➤ Fast calibration of multiple probes ● Large control range ➤ Also suitable for extreme values ● Fast reached equilibrium ➤ Save time ● Portable, stainless steel housing ➤ On site use, cleanable surfaces N HygroGen 1A A self-contained humidity generator for calibration of humidity instrumentation requires no external resources except mains power, and is light enough to be portable for use on-site. The wide control ranges of 5...95 %RH / 5...50 °C and the extremely control stability make the HygroGen devices indispensable wherever there is a need for fast and precise calibration. HygroGen 2A HygroGen 2 includes a sample loop and pump to allow the connection of a chilled mirror reference instrument. The maximum dew point is limited by the ambient temperature through which the sample tubes are connected. HygroGen 0 The HygroGen 0 does not include active temperature control of the chamber. The ambient conditions therefore define the chamber temperature, with carefully designed ventilation ensuring the best possible homogeneity . Order code: see table on next page The HygroGen uses a mixed flow method for generating the humidity required by the user; a desiccant cell provides low humidity and a custom saturator generates high humidity. Temperature is controlled using a Peltier element (Except HygroGen 0). Measurement and control are provided by a combination of a ROTRONIC HygroClip probe and a multi-loop controller. Set-points can be easily adjusted, either via the front panel, and/or via the standard RS232 interface and software. The key advantage of the HygroGen is the speed to reach equilibrium of the set values, which means that a multiple-point calibration check can be performed in minutes, rather than hours. A further feature of the calibration chamber is the provision of two additional probe connection points, enabling calibrated reference probes to be added. Probe options The HygroGen chamber includes three internal connection sockets for the control and optional monitoring probes. As standard, a HygroClip S1 probe is used for %RH measurement and control, and a special Pt100 direct HygroClip for temperature. Depending on the application, a variety of different configurations are possible, the most common being to add a second HygroClip reference probe into a spare connection socket. When any standard HygroClip is connected, the DIO digital signal is available on the rear panel of the HygroGen for connection to a HygroLab or HygroPalm display instrument using a B5-02-B5 cable. 104 M o bile ROTRONIC Humidity and Temperature Generator C A Technical data and Order Information Specification Control range maximum: Control range minimum Control stability Temperature gradient Typical time to set-point L HygroGen 0 HygroGen 1A HygroGen 2A 5...95 %RH 5...95 %RH and 5...50 °C 10...90 %RH over the range of 10...30 °C 10...90 %RH over the range of 10...50 °C N/A ≤ ± 0.3 %RH, 0.1 °C (at 23 °C) 0.2 °C (full range) ≤ �0.2 °C at 23 °C 2 minutes (35 to 80 %RH 2 minutes (35 to 80 %RH change at 23 °C), change at 23 °C) 10 minutes (23 to 45 °C change) HygroClip S, calibrated at 5, 23 & 50 °C / 10, 35, 65 & 95 %RH (N.I.S.T. traceable – North American Market) �≤ ± 1 %RH (10...95 %RH) ±0.3 K at 23±5 °C No Yes Ethernet, ROTRONIC DIO (two connections fitted) Molecular sieve, user refillable Front panel fill. Low level warning on controller Approximately 2 liters 455 x 420 x 212 mm (maximum) Max. 80 %RH at 10...30 °C Max. 80 %RH for temperatures up to 31 °C, decreasing linearly to 50 %RH at 40 °C. Indoor use only. Altitude up to 2000 m 15 kg 17 kg 17.5 kg 110/230 VAC, 3 A 50/60 Hz, Class1 EN61326: 1998, EN61000-3-2: 2000, EN61000-3-3: 1995, EN61010-1: 2001 Standard control probe Control probe accuracy Pump and sample loop connectors External interface Desiccant Saturator Chamber volume Enclosure dimensions Environment Weight Power Approvals I B R A T I O N Order codes Humidity and Temperature Calibrator. Includes 1x HG-DC, 1x HG-FILL, instructions. Chamber doors to be ordered separately Humidity and Temperature Calibrator with rear panel sampling points and pump for connection of reference hygrometer. Includes 1x HG-DC, 1x HG-FILL, operating instructions. Chamber doors to be ordered separately. HygroGen 0 Humidity Calibrator. Includes 1x HG-DC, 1x HG-FILL, operating instructions. Chamber doors to be ordered separately. Accessories & Spares HG-D-11234 Chamber door, for five probes, 25, 20, 15, 15 and 10 mm (including plugs) HG-D-11111 Chamber door, for five 15 mm diameter probes (including plugs) HG-D-xxxxx Chamber door for max. 5 probes, custom configuration, including plugs. Configuration see table below. HG-D-99999 Clear chamber door with 5 adjustable probe fittings for probes with 9...17 mm Ø HG-DP-99999 Insulated chamber door with 5 adjustable probe fittings for probes with 9...17 mm Ø HG-D-00000 Clear chamber door without openings, for calibration of e.g. data loggers with displays HG-Bxx Customer specified plugs where xx = probe diameter, see table below HG-B25A 25 mm plugs with Ø 6mm hole for Pt100 or cable HG-DC Additional desiccant cartridge , pre-filled with molecular sieve HG-DES Refill pack of molecular sieve desiccant HG-FILL Fill tube and syringe HG-CON Spare/replacement controller, supplied pre-configured and with backup disk HG-TC HygroGen heavy duty transit case HG-ICS Inner chamber sleeve (spare part) HG-ITOOLS PC software for controller; enables PC view of controller set-points, graphing of set points & process variables and loading of controller upgrades 11.01.6218 RS232 cable, HygroGen control to PC B5-02-B5 Interface cable, control or reference probes to HygroLab or HygroPalm 2/3 Probe & Display Options HygroClip-S1 Control or reference probe with Swiss Calibration Service calibration certificate (one included as standard) HygroLab 2 Bench-top display unit for control/reference probes (needs 1x B5-02-B5 per probe) AC1207 Power adapter for HygroLab (required) HygroPalm 2 Hand-held display unit for control/reference probes (needs 1x B5-02-B5 per probe) HygroGen 1A HygroGen 2 A Order codes for chamber doors and plugs x= Ø (mm) Example: 1 15 2 20 3 25 HG-D-11234 HG-B-7 4 10 5 5 6 12 7 18 8 30 9 9-17 A 6 B 4 C 22 D 23 E 13 F 19 G 21 H 18.5 I 18.2 Door for 2 x 15 mm, 1 x 25 mm, 1 x 20 mm, 1 x 10 mm probes with plugs Plug 18 mm Ø 105 S Software Overview O Most instruments produced by ROTRONIC feature a practical bi-directional interface for instrument configuration, the display of measured data and the download of recorded measurements from data loggers. Software is developed and maintained in-house at ROTRONIC by a skilled team of software developers, which ensures optimum performance with fast and competent support. F T Since Rotronic first supplied PC compatible instrumentation, we have received many customer requests for new features and enhancements. The feedback we receive is always considered when we are developing our software. Together with the new HygroLog NT, HW4 software is a new development, with most features suggested by our customers. HW4 is probably the most comprehensively featured and user friendly package on the market today. W It is impossible to detail the functionality of HW4 here. We have prepared a free trial version for your convenience. Visit http://www.rotronic.ch/link/hw4 A HW4 Software overview R E Software type HW4 Trial Product key 05 xxx HW4 -E Product key 24 xxx Application Trial version HW4 -P Product key 64 xxx Networked applications in the pharmaceutical and food industry HW4-OPC Product key 88 xxx Networked applications with integration in customer’s software programs For users who are subject to regulatory requirements. (GxP) Software for the older devices such as HygroLog and HygroLog D HW4-VAL Product key 12 xxx HW3 Product key 24 xxx Single instrument applications Functionality Full functionality of the Professional Edition, including OPC functions. Limited trial period of maximum 30 days. For users with single instrument applications. Display of an unlimited number of loggers and their respective measurement values, one at a time. Monitoring, data logger programming, data retrieval, scaling, device settings, alarming, service and configuration tool for ROTRONIC devices, date/time synchronization, adjustment and calibration of ROTRONIC probes. No password protection. All functions of the Standard Edition. Compliant with the requirements regarding electronic records and signatures (FDA 21 CFR Part 11). Networking, grouping of devices, graph overlays, printing of protocols. All functions of the Professional Edition. Contains an OPC server by which data can be integrated in customer’s own software such as SCADA, LIMS and BMS software. Same as HW4 OPC. In addition, the “HW4 e-compliance package” is delivered. This substantial documentation supports the regulated user in qualification / validation of HW4-based solutions. Programming of the older generation of data loggers, water activity instruments etc. Aw Quick function, display of measurement values and monitoring of max. 32 devices. Programming of HygroClip Alarm. Qualification / Computerized System Validation Many ROTRONIC customers have come to depend on the accuracy and reliability of our humidity and temperature measurement systems. The advent of PC compatible products for measurement display and display archiving, as well as instrument configuration and maintenance, has opened many new application possibilities. In many high value and critical applications, accurate measurement is only part of the story. Data integrity and security is today an essential requirement, and many customers in the pharmaceutical and food industries must prove that their data is reliable and accurate. For this purpose software must be validated. ROTRONIC understands these requirements and provides solutions to our customers. The validation and compliance declaration, ERES white paper regarding electronic records and signatures as well as document templates for the system validation are available. Of particular importance is the fulfilment of the requirements of GxP and “E-compliance”. 21 CFR Part 11: Guideline of the American Food and Drug Administration (FDA). Specifies the requirements regarding the handling of electronic records and signatures. EU-Annex 11: Annex 11 regarding computerized systems to the “EU-Guidelines of Good Manufacturing Practice for Medicinal Products” Specifies the requirements regarding the use of computerized systems in GxP processes. GxP: Good “x” practice, where “x” means: Clinical (C), Distribution (D), Laboratory (L), Manufacturing (M). PIC/S: Guidance PI-011-2 “Good Practices for Computerized Systems in regulated GxP environments”. Gives the “regulated user” instructions regarding the basic requirements for the use of computerized systems in GxP processes. Electronic Records: Electronic recording of measurement data, events and configuration parameters. Electronic Signature: Electronic signatures are signatures in digital form that allow the identification of users and devices when used with HW4 software. Audit Trail: System control routine which allows the tracking of data entry or processing of files to their origins. (APV). 106 Fe ature Overview S O F Validated software FDA 21 CFR Part 11 compliant. T W Connect transmitters for configuration, calibration, measurement display and data acquisition. A R E Connect handheld instruments for configuration, calibration, display and to record measured values. Program data loggers and download data. Setting and notification of alarms, audible, visual, SMS or e-mail. Monitoring and display of water activity measurements including accelerated analysis and automatic data capture. Display measured values from a network of HygroFlex or HygroLab instruments. Control the calibration and adjustment of digital probes, including production of calibration certificates. 107 Software Overview S A R E 108 X X X X X X X X X X X X X X X X X X Max.32 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X HW3 HW4-VAL W Measurement data / monitoring Scope presentation of measurement values for single and multiple devices Scope presentation of an unlimited number of measurement values Scope presentation of measurement values in groups Comparison and overlay of measurement values of different groups ROTRONIC networkable (unlimited number of devices) Data storage Automatic storage of measurement data (monitoring) New file creation period freely selectable Presentation of measurement data Numerical and graphical presentation Graphical comparison and overlay function Graphic tools and alarm display Process display (01/2007) File format / data handling / Export functions Protected file format (Binary) and export to text format Text format Analysis and calculations tool Psychrometric calculations Statistics Printing / protocols Automatic creation of adjustment, calibration and configuration protocols Numerical and graphical print out of measurement data Users and passwords Password protection User and user rights freely selectable Alarms Visual presentation of active alarms Alarming via e-mail, SMS Alarm thresholds and alarm events freely definable Alarm acknowledgment Alarming: visual, by relays, printing of alarm report OPC Server (OLE for process control) Server client functionality Electronic records, electronic signatures, audit trail (ERES) Registration of all HW4 user events and automatic creation of protocols Detection and tracking of manipulations granted at any time Tracking by protocols of all alarms and manipulations Self event logging Automatic electronic signature on all text files (protocols etc.) Standards, Laws, Guidelines, Directives FDA 21 CFR Part 11 FDA 21 CFR Part 11, Drugs and 21 CFR 110, Human Food EU Guidelines of Good Manufacturing Practice of Medicinal Products EU Annex 11 to the EU Guidelines of Good Manufacturing Practice of Medicinal Poducts Pic/s Guidance PI -011-2 “Good Practices for Computerized system in Regulated GxP” environments GAMP® 4 guide Validation of Automated Systems GAMP® Good Practices Guide “ A Risk – Based Approach to Complainant Electronic Records and Signatures Validation System Qualification Guide CD (English) White Paper conformity Qualification report ERES assessment System validation guide System validation test report Instruction manual: Software and all associated devices Inspected by external supervisor HW4-OPC T All versions of HW4 support HygroLogNT, HygroFlex, HygroLab, HygroPalm, M33, IOEM and future devices. HW3 supports HygroLab Aw-Quick, HygroLog D, HygroWin, MOK-WIN, M1, HygroClip Alarm. All software versions are multilingual. HW4-P F Functions overview HW4-E O X X X X X Software Overview HW4-P HW4-OPC HW4-VAL X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X O HW3 All versions of HW4 support HygroLogNT, HygroFlex, HygroLab, HygroPalm, M33, IOEM and future devices. HW3 supports HygroLab Aw-Quick, HygroLog D, HygroWin, MOK-WIN, M1, HygroClip Alarm. All software versions are multilingual. Help Documentation, guidance Online help, remote maintenance, Internet download and update information Supported interfaces USB, Ethernet, WLAN, Bluetooth, modem connection RS232 RS485 OPC Diverse auto functions Autostart Automatic file retrieval and archiving of logged data (04/2006) Device specific functions Device settings, scaling, programming, data retrieval, monitoring, data logger function Monitoring, alarming, servicing and configuration of ROTRONIC devices Adjustment and calibration of ROTRONIC probes Date / Time synchronisation Supported operating systems Microsoft Windows 95, 98, ME, NT, 2000 Microsoft Windows NT4 (SP6a), 2000, XP, Server 2003, or better Central software management, multi-user compatible HW4-E S F X T X X W A R E X Validation All versions of HW4 are validated and controlled by an external body. COMPLIANCE DECLARATION DV04-30.787.01-1 for Software HW4 version 1.2.1.14714 physical devices HygroLogNT: firmware release 1.2 HygroFlex, HygroLab, HygroPlam, HygroMid: firmware release 4.0 We attest that the validated version of the rotronic HW4 software and associated devices fulfill the requirements defined in the rotronic ERES White Paper, version 1.0, based on the following paragraphs: 21 CFR Part 11 21 CFR 110 21 CFR 210-211 EU Annex 11 validated by ROTRONIC Instrument Corp. Inspected by Kereon AG, December 2005 The HW4 software and devices have been reviewed against the specifications and the ERES White Paper, version 1.0, in order to provide evidence that the above mentioned regulations are fulfilled accordingly. The measuring devices and the software have been validated and verified against the specifications provided by the manufacturer. Inspected by Yves Samson Kereon AG Accepted by the manufacturer ROTRONIC AG 109 S O F T HW4 Functions Viewing of measurement values / monitoring Viewing of measurement values is very easy and user-friendly. Files of any device present in the device tree may be directly copied to a PC and opened by the HW4 explorer. Data is presented either in graphical mode or as a table. In the online monitoring mode, both a table and graph are displayed. W A R Presentation of measurement values E The measurement values may be displayed as a graph or in table form. The graph module may be configured by the user. Archiving measurement data Measurement data can be automatically written into different files. The user may configure the system to create a new file e.g. every month or after 200,000 measurements. File formats / handling data / export functions The file format may be determined by the user. For log files, the formats .xls and .log are available. The .LOG format saves the data in a binary format, which can be read by HW4 only, while the .XLS formatted files can be opened by a standard editor or MS Excel. Data may be exported. Psychrometric calculations tool All ROTRONIC instruments measure percentage relative humidity (%RH) and temperature (°C/F). From the two values it is possible to calculate other psychrometric values such as dew point, frost point, wet bulb temperature, mixing ratio, absolute humidity, enthalpy, partial water vapor pressure, saturation vapor pressure and more. The calculation software in HW4 uses WMO* verified formula to make these calculations, and also provides the user with the option to input their own parameters (e.g. input mixing ratio and temperature to calculate %RH). Other advanced options such as dew/frost differentiation, and pressure or altitude compensation are included. * World Meteorological Organization 110 HW4 Functions S Statistical functions O The detailed log data, which may be considerable, is of little interest for many users. For them, it is only important whether or not the values were within certain ranges during the period of interest. The statistical functions allow a fast overview. F The statistics will show the following values: • • • • • Minimum Maximum Average Standard deviation Number of measurements T W A R E Printing /protocols If so desired, protocols may be printed. The user may determine whether the standard editor or MS Word should be used for that purpose. Users and passwords User name and passwords may be assigned freely. Each user may be assigned different rights. Users that have been deleted cannot be created under the same name. Alarms When in monitoring mode, HW4 can trigger an alarm when predefined conditions prevail. An alarm condition may be present when a device or file storage path is not available, a software error happens, measurement values exceed defined ranges or a logger sends an error message. Alarms can be displayed on the screen, printed out or forwarded by e-mail. Mails can be sent to single or multiple recipients. OPC Sever (Object Linking and Embedding for Process Control) HW4-OPC features an OPC Server which enables the data integration into third party software. 111 S O F Instrument Network Bus Systems The availability of bus systems was an often discussed issue in the past. The huge choice of available systems and the comparatively small demand always led to the decision not to develop and offer bus systems in the short term. Currently far more than hundred different systems are available on the market. The growing variety of industrial networks demands flexible solutions for the realization of a bus interface. T Meanwhile, a few systems are established as quasi standards. ROTRONIC has developed a new transmitter with modular bus interface for these standard systems: the DI-BUS. Due to the modularity of the used interfaces, the question of the right system has become obsolete. We shall be able to offer a bus-compatible measurement system beginning autumn 2006. W The system consists of a digital measuring transmitter for digital HygroClip Industrial probes, which features an interface for the integration of various optional bus modules. Depending on the desired bus type, simply use a different module! A R E DI-BUS Digital transmitter with bus integration for HygroClip Industrial probes Main features: • • • • • • • One probe input for humidity/temperature measurement Interchangeable probes Digital signal processing 12...24 VDC supply Modular construction Robust housing Suitable for various bus systems The transmitters are delivered without probe and bus module. These must be ordered separately. Suitable probes: all HygroClip Industrial probes may be used. See pages 40-43 Order code: DI-BUS DI-BUS-D Transmitter without display Transmitter with display Following bus-modules are available: Profibus, DeviceNet, CanOpen, ModbusRTU. Further types on request. Bus Functions: • Read measuring values: values • Probe adjustment: Humidity: Temperature: • Measurement value status: • Unit system: 112 Humidity, temperature, calculated single point and multi-point adjustment single point and multi-point adjustment Valid / invalid selectable Instrument Network Bus Systems Specifications DI-BUS Humidity / Temperature sensor Accuracy at 23 ± 5 °C Operating range electronics Measuring range Psychrometric calculations Unit system Supply voltage Output signal Probe adjustment Display Dimensions IP protection grade Housing material Color O HygroClip Industrial probe with Tuchel 7-pin connector (order separately) See pages 40 to 43 Probe dependent Humidity / temperature 0...100 %RH / -40...70 °C / -40...60 ° with display Probe dependent All standard calculations selectable Selectable 12...24 VDC ± 10% Depending on the bus module used Via Bus interface or by separate calibration interface Option 160 x 100 x 55 mm (with connector) IP50/NEMA5 Polycarbonate Black F T W A R E Profibus • • • • • • S Active module with serial and parallel device interface Complete Profibus-DP and DPV1 Slave Max. 400 Byte cyclic input and output data additional acyclic DPV1- parameter data Supports master class 1 and master class 2 read and write functions Potential free Profibus interface with automatic baud rate detection 9.6 kBit/s to12 Mbit/s Order code: DI-BUS-AB6200 DeviceNet • Active module with serial and parallel device interface • Complete DeviceNet 2.0 Adaptor according to ODVA profile Group 2 Server • Max. 512 Byte input and output data (implicit messaging) • Additional acyclic DPV1- parameter data (explicit messaging) • Supports Change-of-State, Cyclic I/O, Polled I/O and bit-strobed I/O • Potential free DeviceNet interface with automatic baud rate detection 125 to 500 kBit/s Order code: DI-BUS-AB6201 CANopen • Active module with serial and parallel device interface • Complete CANopen Slave according to DS301-4 standard. • Max. 32 TPDO and max. 32 RPDO Process data objects: totally max. 256 Byte Process data. • Additional 16383 SDO Objects for parameter data • Potential free CANopen interface with automatic baud rate detection 10 / 1000 kBit/s • Connection via 5-pin screw terminal with external 24 V supply Order code: DI-BUS-AB6202 Modbus-RTU • • • • • • • Active module with serial and parallel device interface Complete Modbus-RTU / ASCII Server (Slave) interface Max. 400 Bytes I/O Data Acyclic parameter data transmission Modbus-RTU/ASCII Class 0, Class 1 and partly Class 2 Functions Baud rates: 1.2 kBit/s to 115 kBit/s. RS232 or RS485 connection Order code: DI-BUS-AB6203 113 Sample Containers, Humidity Standards and Filters A C C E S S O R I E S Order code Description Disposable sample containers PS-14 Pack of 100 disposable plastic sample containers, for all sample holders of 14 mm height PS-40 Pack of 100 disposable plastic sample containers, for all sample holders of 40 mm height Humidity Standards EA00 Humidity Standard 0.5 %RH EA05 Humidity Standard 5.0 %RH EA10 Humidity Standard 10.0 %RH EA11 Humidity Standard 11.3 %RH EA20 Humidity Standard 20.0 %RH EA35 Humidity Standard 35.0 %RH EA50 Humidity Standard 50.0 %RH EA65 Humidity Standard 65.0 %RH EA75 Humidity Standard 75.3 %RH EA80 Humidity Standard 80.0 %RH EA95 Humidity Standard 95.0 %RH Filter for BFC and water activity probes W-24 Flat wire mesh filter with retaining ring, Ø 24 mm for AW-DIO, BFC-DIO, BFC-DIO-T7 probes, Mesh size approx. 20...25 µm, Material: DIN 1.4401 S23 Flat sinter filter with retaining ring, Ø 23 mm, for AW-DIO, BFC-DIO, BFC-DIO-T7 probes, Pore size approx. 5 µm W-37 Flat wire mesh filter with retaining ring, Ø 37 mm for AWVC, AWVD and BFC probes, Mesh size approx. 20...25 µm, Material: DIN 1.4401 Filters for probes with Ø 5 and 10 mm MF05 Teflon filter for Ø 5 mm probes Outer diameter 7 mm Pore size approx. 10µm MF12 Teflon filter for Ø 10 mm penetration probes Outer diameter 12 mm Pore size approx. 10µm ET-Z10 Steel sinter filter for Ø 10 mm penetration probes Outer diameter 10.5 mm Pore size approx. 5µm Material: DIN 1.4401 Filters for industrial probes -50...200 °C SP-MSB15 Filter carrier (direct screw-on) Slotted sleeve for Ø 15 mm probes Nickel-coated brass 114 SP-S15 Steel sinter filter element for Ø 15 mm probes Pore size approx. 5µm Material: DIN 1.4401 BS15 Steel sinter filter element for Ø 15 mm probes with filter carrier (direct screw-on) Pore size approx. 5µm Material: DIN 1.4401 SP-M15 Wire mesh filter for Ø 15 mm probes Mesh size approx. 20...25 µm Material: DIN 1.4401 Filters (continued) Order code Description BG15 Wire mesh filter element for Ø 15 mm probes with filter carrier Mesh size approx. 20...25 µm Material: DIN 1.4401 SP-T15 Teflon filter element for Ø 15 mm probes Pore size approx. 10µm A C C E S S O BF15 Filters for ambient probes SP-FN15 Teflon filter element for Ø 15 mm probes with filter carrier Pore size approx. 10µm Steel sinter filter for Ø 15 mm probes direct screw-on, -50...200 °C Pore size approx. 5µm Material: DIN 1.4401 Steel sinter filter for Ø 25 mm probes direct screw-on, -50...200 °C Pore size approx. 5µm Material: DIN 1.4401 SP-W15 Wire mesh filter in PPS cage for Ø 15 mm probes direct screw-on, -50...200 °C Mesh size approx. 20...25 µm Material: DIN 1.4401 SP-W25 Wire mesh filter in PPS cage for Ø 25 mm probes direct screw-on, -50...200 °C Mesh size approx. 20...25 µm Material: DIN 1.4401 Ditto, white D15G D15G-White Teflon filter in PPS cage for Ø 15 mm probes direct screw-on, -50...200 °C Pore size approx. 10µm SP-TF25 Teflon filter in PPS cage for Ø 25 mm probes direct screw-on, -50...200 °C Pore size approx. 10µm Ditto, white PE15 SP-PE15G-N S Wire mesh filter in polycarbonate cage for Ø 15 mm probes, direct screw-on, -40...85 °C Mesh size approx. 20...25 µm Material: DIN 1.4401 Ditto, white SP-TF15 SP-TF3-25 I E SP-FN25 SP-W3-25 R Polyethylene filter for Ø 15 mm probes in polycarbonate cage, direct screw-on, -30...80 °C Pore size approx. 10 µm Ditto, grey cage for Roline L-transmitters SP-NC15 PPS slotted sleeve for Ø 15 mm probes, direct screw-on, -50...200 °C No filter, protection against contact only SP-NC25 PPS slotted sleeve for Ø 25 mm probes, direct screw-on, -50...200 °C No filter, protection against contact only 115 M a t i n g C onnectors, Carry Cases, Cable Glands and Mounting Flan ge s A C Order code Mating connectors ET-229 Description ET-230 Tuchel connector 4-pin, female S ET-233 Tuchel connector 7-pin, male S ET-234 Tuchel connector 7-pin, female ET-240 Lemo connector, 5-pin, male ET-409 Binder connector 4-pin, male. For Pt100 to T1, HygroClip TH100, docking stations of HygroLog NT ET-410 Binder connector 4-pin, female ET-411 Binder connector 3-pin, male, for remote logger HygroLog NT ET-413 Binder connector 5-pin, male MOC Connector for HygroClip S MOC3 Connector for HygroClip S3 Carry cases AC1102 Carrying case for GTS AC1116 Carrying case for HygroPalm and HygroClip S AC1117 Carrying case for HygroPalm and HygroClip HS28 AC1119 Carrying case for HygroPalm-AW AC1121 AC1122 Carrying case for HygroLab Universal carrying case or HygroLog, HygroPalm 0 C E O R I E S Tuchel connector, 4-pin, male Cable glands and mounting flanges AC1301-M Cable gland AGRO, with Perbunan gasket(<100 °C), for Ø 15 mm industrial probes, metric thread M20 x 1.5 nickel coated brass 116 AC1301-MEX Ditto, with metric thread for HygroClip EX probes AC1302-M Cable gland AGRO, with Perbunan gasket(<100 °C), for Ø 25 mm industrial probes, metric thread M32 x 1.5 nickel coated brass AC1303-M Cable gland AGRO, with Viton gasket (<200 °C), for Ø 15 mm industrial probes, metric thread M20 x 1.5 nickel coated brass AC1304-M Cable gland AGRO, with Viton gasket (<200 °C), for Ø 25 mm industrial probes, metric thread M32 x 1.5 nickel coated brass AC1305 Mounting flange for AC1301-M and AC1303-M Ø 80 mm nickel coated steel AC1306 Mounting flange for AC1302-M and AC1304-M Ø 80 mm nickel coated steel Calibration Devices Order code EBFC Description Calibration device for plate probes BFC / BFC DIO EDM-15-15 Calibration device for 2 Ø 15 mm probes Push-on type EDM-15-25 Calibration device for 1 Ø 15mm and 1 Ø 25 mm probe screw-in type A C C E S S EGL EGS Calibration device for Ø 10 mm probes Push-on type Calibration device for all sword probes Push-on type EM-15 Calibration device for Ø 15 mm probes screw-in type ER-10MS Calibration device vertical for M1S Push-on type EM-25 Calibration device for Ø 25 mm probes screw-in type EM-G Calibration device for probes type E, HP... IE... screw-in type EMV-15 Calibration device vertical for Ø 15 mm probes screw-in type EMV-25 Calibration device vertical for Ø 25 mm probes screw-in type ER-05 Calibration device for Ø 4 / Ø 5 mm probes Push-on type ER-15 Calibration device for Ø 14...15 mm probes Push-on type ER-18K Calibration device for Ø 18 mm probes Push-on type ER-20K Calibration device for 20 mm probes Push-on type ERV-15 Calibration device vertical for Ø 15 mm probes Push-on type WP14-S Calibration device for bell probes AWD, AWVC, AW-DIO, Stainless steel, DIN 1.4401 O R I E S 117 Accessories A C Order code Mains adaptors Description E ACA-HP S AC1211 Mains adaptor RNG 11, 9V/ 200 mA, 3.5 mm Stereo jack, tip + Mains adaptor for HygroLog NT series, 12 VDC S Service cables for Transmitters ACML232 Service cable for M23 and M33 transmitters C O R For scaling, adjustment and programming of the transmitters with a PC and HW3 software I E S ACRLXB5 Service cable for M-Series and Roline L-transmitters Probe adjustment with HygroPalm or HygroLab, no scaling of analog outputs. Probe adjustment, scaling and programming with a PC and HW3, using a HygroPalm 2 or 3 handheld or a HygroLab 2 or 3 bench top device. ACRLYB5 Service cable for M-Series and Roline L-transmitters Probe adjustment and validation of the analog outputs with HygroPalm or HygroLab. Works only in conjunction with ACRL001-ACRL420 Simulators for HygroClip S probes HCLPS-XXH/XXC HygroClip S simulator with predefined values Simulators for HygroClip industrial probes AC1618/XX-XXX HygroClip – Industrial probe simulator with T7 connector Temperature adaptor HygroClip HygroClip-TH100-B5 Temperature adaptor for HygroPalm probe input 2, HygroLab, HygroFlex 3 probe input 2 HygroClip-TH100-DAT05 Temperature adaptor for HygroPalm probe input 1 HygroClip-TH100-T7 Temperature adaptor for HygroFlex probe input 1 Extension cables for Pt100 probes (max. -40...90 °C) AC1607/xx Extension cable for Pt100 probes xx= length in m Available lengths: 1, 2, 3, 5, 10, 15, 20 m 118 Any value is possible. Order code: HCLPS-[0...100]H/[-50…100]C (negative values depicted by “-“ Example: HCLPS-35H/-25C for 35 %RH and -25°C Any value is possible. Order code: AC1618- /[0…100]-[-50…200] (negative values depicted by “-“. Example: AC1618/35/-40 for 35 %RH and -40°C Accessories Order code Description Extension and adaptor cables for HygroClip S probes MOK-xx-B5 Adaptor cable for HygroClip S probes Suitable for HygroLab, HygroPalm probe input 2, HygroLog NT, docking stations with HygroClip probe input. xx = length in m Binder connector. Available lengths: 1 m, 2 m, 5 m MOK-xx-DAT05 Extension cable for HygroClip probes with DAT05 connector xx = length in m Available lengths: 1 m, 2 m, 5 m A C C E S S O R Calibration cable for HygroClip S, with serial port D-sub25 /D-Sub 9 connector for PC RS232 Interface Available length: 3 m MOK-xx-XX Extension cable with open strands for HygroClip S xx = length in m Available lengths: 1 m, 2 m, 3 m, 5 m MOK3-xx-XX Extension cable white, with open strands for HygroClip S3 xx = length in m Available lengths: 1 m, 2 m, 3 m, 5 m AC1604 Extension cable Binder 5-pin male / female Available length: 2 m Extension, adaptor and calibration cables for HygroClip Industrial probes AC1616/xxx Probe extension cable for HygroClip Industrial probes with Tuchel 7-pin connector, connects to HygroFlex Available lengths: xx = length in m 2 m…200 m AC1676-x Adaptor cable for BFC-DIO probes to HygroFlex Tuchel 7-pin connector / Binder 5-pin connector (female) xx = length in m Available lengths: 1 m, 4 m, 5 m T7-03-WIN Calibration cable for HygroClip Industrial probes, with serial port D-sub25 /D-Sub 9 connector for PC RS232 Interface Cable length: 3 m T7-0.5-B5 Adaptor cable for HygroClip Industrial probes. Tuchel 7-pin female and Binder 5-pin male connectors Cable length: 0.5 m T7-03-B5 Adaptor cable for HygroClip Industrial probes. Tuchel 7-pin female and Binder 5-pin male connectors Cable length: 3 m T7-03-DAT05 Adaptor cable for Industrial probes to HygroPalm /HygroLog MOKX-03-WIN I E S Remote and calibration cables AC1620 Remote cable HygroFlex <> HygroPalm 2/3, B5 connector AC1621 Remote cable HygroFlex <> HygroPalm 2/3, DAT05 connector AC1622 RS232 cable HygroPalm <> PC AC1623 Configuration cable HygroFlex PCB <> PC AC1624 RS232 cable HygroFlex B5-(763) connector<> PC AC1625 Calibration cable M1xS <> HygroPalm 2/3 AC1628 Calibration cable HygroClip I-EX <> HygroPalm 2/3 SPB5-WIN Calibration cable HygroClip I-EX <> PC Zener barriers for HygroClip EX probes ZB1 Zener barrier Z722 for application with HygroFlex transmitter ZB2 Zener barrier Z722 and housing for 4 Zener barriers ZB1-420 Zener barrier Z788H for loop powered 4...20 mA application without HygroFlex transmitter ZB2-420 Zener barrier Z788H and housing for 4 Zener barriers Adaptor for compressed air for screw-in probe HygroClip IE Pressure-FI1 Pressure adaptor for screw-in probe HygroClip IE-1 (1/2 “ G thread). Max. 16 bar 119 Humidity Measurement in Air T H E O R Humidity in the form of water vapor is always present in the air. It is measured either as absolute or relative humidity. These two terms are defined as follows: Absolute humidity of a gas mixture The absolute humidity of a gas mixture is defined as the quantity of water vapor (kg) contained in each volume of the gas mixture. It is expressed in terms of kg water vapor per kg gas mixture. The water vapor present in the gas mixture generates a pressure, which is part of the total barometric gas pressure. The vapor pressure and the absolute humidity cannot exceed the saturation level at a given temperature. Above this level, water is separated out in liquid form. The maximum pressure is described as saturation pressure and is highly temperature dependent. The absolute humidity of the air is of limited practical significance, because one essential factor, the temperature, is not taken into account in the determination of absolute humidity. Relative humidity of a gas mixture Relative humidity is defined as the ratio of the actual water vapor pressure to the highest possible water vapor pressure at a given temperature: Y %RH = 100 x p/ps p = Water vapor pressure in the gas mixture at ambient temperature ps = Saturated water vapor pressure at ambient temperature Therefore, 100 %RH corresponds to the maximum amount of water vapor, which a gas mixture can contain. Below the saturation level, the water vapor pressure (p) and hence also the relative humidity (%RH) are proportional to the total barometric pressure. Since the highest possible water vapor pressure (ps) is extremely temperature dependent, the relative humidity is also temperature dependent. The relative humidity therefore decreases, when the temperature rises, and vice versa. Influence of temperature fluctuations of ±1 °C at various temperatures and humidities: %RH 10 %RH 50 %RH 90 %RH 10 °C ±0.7 %RH ±3.5 %RH ±6.3 %RH 20 °C ±0.6 %RH ±3.2 %RH ±5.7 %RH 30 °C ±0.6 %RH ±3.0 %RH ±5.4 %RH 50 ±0.5 %RH ±2.6 %RH ±4.6 %RH C 70 °C ±0.5 %RH ±2.3 %RH ±4.1 %RH It is extremely important that the probe and the sample to be measured have the same temperature to achieve useful measurements. To gain a better understanding of the relationships, we refer to the h-x diagram of humidity in air (Mollier’s diagram). This illustrates clearly the relationship between temperature, moisture content and relative humidity. Relative humidity below 0 °C At temperatures below 0 °C, the saturation pressure above water in liquid form differs from the saturation pressure above ice: (ei). ew = Water vapor saturation pressure above water at ambient temperature ei = Water vapor saturation pressure above ice at ambient temperature T °C 0 - 5 -10 -15 -20 -25 -30 ew hPa 6,11 4,22 2,87 1,91 1,26 0,81 0,51 ei hPa 6,11 4,02 2,60 1,65 1,03 0,63 0,38 %RH – 100 95 91 87 82 78 75 For this reason, a measurement of 75 %RH at -30 °C corresponds to saturation (100 %RH) above ice. 120 Humidity Measurement in Solids T Similar to gases, solids such as paper or food can also absorb and retain water as well as desorb it. Materials with this property are called hygroscopic. Depending on the point of view, there are two different observations that characterize the humidity state of a material. Water content H E The water content of a material is the amount of water contained in the material, expressed in percentage of weight. This aspect is interesting for situations where a material is sold by weight. However, if we talk of the physical properties of a material, then the water content is of no interest, as it provides no meaningful information. O Equilibrium humidity A hygroscopic material tries to establish equilibrium of its humidity with that of its environment. The presence of water in the material produces a water vapor pressure (pm) on the material surface. If this pressure (pm) is equal to the water vapor pressure (p) of the ambient atmosphere, then the material achieved equilibrium humidity with its environment. Any difference between the pm and the p produces a water exchange and therefore a change of the water content of the material concerned, until equilibrium is achieved. Equilibrium humidity of a material is therefore defined as the relative humidity of the ambient atmosphere that has to prevail in order to cause no exchange of water. R Y Water activity The relative humidity, which must prevail in the surrounding atmosphere to avoid water exchange between material and air, is defined as water activity. It is practically the same as the equilibrium humidity of a material in the definition, but is not stated in 0….100 %, but in 0…1 aw. The water activity is a measure of the degree of freedom of the water retained in various ways in a material. The water activity directly determines the physical, mechanical, chemical and microbiological properties of the material as well as interactions, such as pourability, lump formation, cohesion, static electricity, etc. In the food industry, water is a highly significant factor in the shelf life of semi-finished and finished products. Sorption isotherms At equilibrium, the relation between water content and equilibrium humidity of a material can be displayed graphically by a curve, the so-called sorption isotherm. For each humidity value, a sorption isotherm indicates the corresponding water content value of the material at a given, constant temperature. If the composition or quality of the material changes, then its sorption behavior also changes. Because of the complexity of sorption processes, the isotherms cannot be determined by calculation, but must be recorded experimentally for each product. Therefore in practice, water content and water activity should be viewed as two independent parameters. Accuracy of HygroClip probes (* = with SCS certificate) Humidity Temperature Standard SCS If a probe has been operated for prolonged periods of time, it may show too high values by approx. 2 percent when operated at low humidity afterwards. The probe can be regenerated by heating it during two hours at 120 to 150 °C / < 10 %RH. 121 T H E O R Y 122 HX Diagram Explanations to the h-x Diagram T 1 Signs and symbols 1.1 1.2 1.3 1.4 1.5 ß: t: x: h: ϕ: Dry air quantity in kg per m3 process air Temperature of the process air in °C Water vapor content in g per kg dry air of the process air Heat content (enthalpy) in kJ per kg dry air of the process air Relative humidity of the process air 1.6 ∆h: Heat consumption in kJ per kg water ∆x NB: We designate process air as air in different states, as found during drying (fresh air/warmed air from the furnace and/or a heater/conditioned air, also exhaust air). 2. Use of the h-x diagram H E O R 2.1 Dry air porition ß in kg per m3 process air Example: Measured values of the exhaust air in a drying plant tA=46°C; ϕ =80%RH; exhaust air quantity 12000m3/h The line drawn parallel to the dotted lines of the diagram through the status point of the exhust air (Intersection of the t-line 46°C and the humidity curve 80%) results in its extension at the Intersection with the left margin scale at ß=1,018kg dry air per m3 of this exhaust air. At 12000m3/h, the dry air quantity is thus 12000 • 1,018=12200kg/h. Y 2.2 Water vapor content in g per kg dry air of the process air 2.2.1 The vertical line drawn through the status point (in our example 46°C; 80%RH) results at the intersection with the horizontal abscissa a water vapor content of x2=54g per kg dry air of this exhaust air. 2.2.2 If the hot air fed into the drying chamber is created by heating outside air (in the example temperature 20 °C; 70 %RH) this hot air contains x1 = 10 g hot water per kg dry air (determination of x1 as described in 2.2.1]). This means that each kg of dry air has absorbed ∆x = x2- x 1 = 44 g of water. 2.2.3 With 12200kg dry air/h, 12200 • 0,044=536,8kg water are withdrawn from the product being dried per hour. 2.3 Heat content in kJ per kg dry air of the processed air. 2.3.1 The line drawn parallel to the lines of equal heat content (h lines) through the status point (in our example 46°C; 80%RH) results on the one hand at the intersection with the inclined abscissa in a heat content h2=185kJ/kg dry air of this exhaust air. (Conversion to kcal: 1 kcal=4,1868 kJ). On the other hand this extended parallel line in the upper part of the diagram helps to determine the approximate hot air temperature (see 2.5) for this heat content. 2.3.2 The heat content of the outside air (in our example 20 °C; 70 %) is h1 = 45 kJ, (determined as described in 2.3.1) so that heating by ∆h=h2-h1=140 kJ per kg dry air is necessary for drying. However, the actual heating must be higher than this ∆h, due to various heat losses such as radiation, heating of the goods to be dried, the drying cars and frame etc. But for well insulated plants, no more than 15 kJ/kg dry air. 2.3.3 The theoretical heat consumption in our example is thus: 12200 • 140 = 1,708 million kJ/h. 2.4 Theoretically required heat quantity per kg of expelled water: The parallel line drawn through the zero point to the connecting line of the status points for outside air and exhaust air indicates the theoretical heat consumption at the intersection with the right margin scale: ∆h = 318 ∆x kJ theoretical heat consumption kg per kg H2O calculation: ∆h (from 2.3.2) ∆x (from 2.2.2) = 140 = 3182 kJ 0,044 kg 2.5 Hot air temperature The vertical line drawn through the status point of the outside air (see 2.2.2) intersects with the h line of the exhaust air (see 2.2.1) at a particular point. If one draws a line through this point parallel to the lines of equal temperature (t lines), one obtains the theoretically required hot air temperature at the intersection with the ordinate, in our example 157°C. 123 Humidity Definitions T Relative humidity (%RH) H Is defined as the ratio of the quantity of water vapor present in the air to the maximum possible water vapor at the same temperature. Dew point (Dp) E O The dew point is that temperature, where gas being cooled, begins to condense water vapor into liquid water. The dew point may also occur below 0 °C (super-cooled water). This point has to be distinguished from frost point (see below). Frost point (Fp) The frost point is that temperature, where gas being cooled begins to condense water vapor in the form of ice. Frost point occurs only at temperatures below freezing. R Water vapor density (Dv) in g/m3 This is the ratio between the mass of the water vapor to the volume of the gas mixture, in which the water vapor is present. Y Water vapor content (Q) in g/kg This is also called specific humidity and is the ratio between the mass of the water vapor to the mass of the gas mixture, in which the water vapor is present. Mixing ratio ( R) in g/kg This is the ratio of the mass of the water vapor to the mass of the dry gas mixture, in which the water vapor is present. Water vapor partial pressure (E) in hPa This is the pressure of the gaseous phase of the water in a gas mixture. Water vapor saturation pressure (Ew) in hPa This is the maximum pressure that the water vapor can reach at saturation for the appropriate temperature. Enthalpy (H) Enthalpy is the measurement for the determination of the energy required, to change the gas mixture from a certain temperature/humidity state to another. Enthalpy is not used as an absolute value, but as the difference between two points of particular interest. The choice of 0 °C and 0 %RH for zero enthalpy was arbitrary. Mixing ratio/Volume (PPMv) This is the relationship between the number of water vapor molecules to the number of molecules of the other components in the gas. Once this value is determined, it does not change with pressure or temperature. Common faults/remedies Not only humidity, but also many other physical parameters are measured in industrial processes. The most important are temperature, pressure, air speed, etc. The measurement of humidity is different to other parameters in one important aspect, namely that humidity cannot be considered as an absolute value, because the measuring principle is based on the exchange of water vapor between the sensor and the surrounding gas or gas mixture, e.g. air. In our capacity as an experienced manufacturer, we are well aware of our responsibility to provide our customers with instruments, that will withstand even the most demanding operating conditions and which are at the same time easy to use and require little maintenance. However, we wish to remind our customers that our instruments will provide an excellent service and provide accurate results, if the following simple operation and maintenance instructions are followed: 1. Analysis of the measuring medium, in which the probe is to be used. What suspended matter and/or chemicals are present and in what concentration? 2. The probe should be mounted at the correct measuring location, and not where it is most convenient. In case of doubt please contact your ROTRONIC representative. 3. The filter has to be changed regularly if the probe is used in demanding environments. ROTRONIC filters can be cleaned in an ultrasonic bath with suitable detergents. However, it is advisable to keep spares in stock. 4. The functioning of the sensor should be checked every 6 to 12 months. 5. Calibration of the sensor can be performed by the user with the aid of the SCS certified humidity standards, supplied by ROTRONIC. Calibration of the instruments will ensure, that your measurements are always verifiable. 124 ROTRONIC Humidity Sensors With the HYGROMER® series, ROTRONIC provides the most advanced capacitive polymer sensor system for relative humidity measurement. It is the sensor with the largest temperature range (-50…200 °C) available on the market. This measuring principle is recognized internationally and is based on the change of the dielectric properties of a polymer as a function of the prevailing relative humidity. The polymer used for the HYGROMER® sensor is hygroscopic and has a natural tendency towards equilibrium with the humidity environment which surrounds it. A corresponding water vapor pressure is formed at the surface of the polymer depending upon the temperature and the amount of water absorbed into the polymer. Any difference between this water vapor pressure and the water vapor pressure of the environment is balanced by an exchange of water molecules until the two are equal. These changes are measured electrically, amplified and indicated as relative humidity. The amount of water which is absorbed into the polymer is determined by the ambient humidity and temperature, thus the resulting dielectric properties of the sensor reflect the percentage relative humidity (%RH) to which the sensor is exposed. For many years, the ROTRONIC HYGROMER® C94 was the best sold sensor. With the disappearance of the Hygrolyt sensors, new elements were developed in order to even better fulfill customer’s requirements. An industrial sensor does not necessarily need the same properties as a sensor for Water Activity or a sensor for high humidity applications. The new sensors represent the results of continuous research and development. Sensor Designation HYGROMER® IN-1 Temperature range: -50…200 °C Humidity window Used for: Industry applications, meteorology, food technology, Laboratories, cold rooms, drying processes, incubators Improvements: Gold connectors, better chemical resistance, no corrosion after condensation HYGROMER® RS-70 Temperature range: -50…180 °C Used for: High humidity applications, cheese stocks, meat processing, test environments, tropical greenhouses climatic chambers, brick and tile making Improvements: Heated sensor, no condensation, better accuracy in high range of humidity HYGROMER® AC-1 Temperature range: -30…100 ° C Used for: HVAC applications, Cold rooms Storage and transport, wine cellars, greenhouses, museums, churches Improvements: Better chemical resistance, better long term stability HYGROMER® WA-1 Temperature range: -30…100 °C Used for: Water activity applications, food/pharmacy quality assurance, Product stability determination, shelf life determination Improvements: Optimized dimensions for minimal chamber volume, Very little hysteresis T H E O R Y HYGROMER® humidity sensors are always fitted to a probe or instrument. Thanks to the ROV interface, probes and instruments with HYGROMER® sensors can be connected to any display unit with ROV input. (10 mV/ °C and 10 mV/ %RH) Characteristics of the sensor Response time/Time constant The time constant of a sensor is defined as the time required to perform 63 % of a humidity change. The time constant is larger at low temperature, low air movement and high humidity. The time constant also increases when a filter is used. The filter reduces the airflow over the sensor and a slower diffusion of water molecules results in a slower response time. Therefore humidity equilibrium is reached after an extended period of time. Reproducibility The specifications stated refer to a humidity cycle of 10-95-10 %RH. 125 Pollutant Table T H Some gases, especially pure gases, do not influence the humidity sensor. Others have very little influence, and some have important influence. E O R These gases have insignificant or no influence: Argon Carbon dioxide Helium Hydrogen Neon Nitrogen Nitrogen oxides (laughing gas) Oxygen These gases have little or no influence on the sensor and humidity measurement: Ar CO2 He H2 Ne N2 N2O O2 C4H10 C2H6 CH4 Butane Ethane Methane Natural gas Propane C3H8 The following gases have, in the given concentrations, no or little influence on the sensor and the humidity measurement. The data is only a guide. The resistance of the sensor depends strongly on the temperature and humidity conditions and the duration of the exposure to the pollutant. Allowed fault caused from the pollutant: ±2 %RH Y Pollutant Acetic acid Acetone Ammonia 2-Butanone (MEK) Chlorine Ethanol Ethyl acetate Ethylene glycol Formaldehyde Hydrochloric acid Hydrogen sulphide Isopropanol Methanol Methylethylketone Nitrogen oxides Ozone Sulphur dioxide Toluene / Xylene Xylol Formula CH3COOH CH3COCH3 NH3 Cl2 C2H5OH CH3COOC2H5 HOCH2CH2OH HCHO HCl H2S (CH3)2CHOH CH3OH C2H5COCH3 NOx O3 SO2 C6H5CH3 C6H5(CH3)2 Maximum Workplace Concentration ppm mg/m3 10 25 500 1200 20 14 300 1200 0.5 1.5 500 960 400 1400 100 260 0.3 0.37 2 3 10 15 200 500 200 260 200 590 5 9 0.1 0.2 5 13 100 380 100 440 Allowed Concentration Continuous Operation ppm mg/m3 800 2000 3300 8000 5500 4000 150000 0.7 2 3500 6000 4000 15000 1200 3000 2400 3000 300 500 350 500 4800 12000 3500 6000 3300 8000 5 9 0.5 1 5 13 1300 5000 1300 5000 Practical limits The specified operating ranges must be complied with, otherwise significant errors can arise or the measuring element could be destroyed. A replaceable dust filter must be used in dusty environments. Oil and grease vapors will damage the sensor, as they can condense on the sensor and thus prevent or inhibit response (insulating layer). Flue gases can therefore not be measured . A filter must be used at air velocities above 3 m/s. The sensor must also be protected mechanically from the high air velocities above 40 m/s (for filters, see general accessories). Sensor properties HYGROMER® Operating range Humidity Temperature in °C Air velocity in m/s without sensor protection with sensor protection Output signals Reproducibility Long term stability Time constant at 1m/s air speed Typical operating lifetime Saturation resistance Pressure dependence Maintenance interval Energy requirement/stability 126 IN-1 0…100 %RH -50…200 AC-1 WA-1 RS-70 -30…100 3 m/s 20 – 40 m/s capacitance range better than 0.5 %RH <1%RH/12 months <12 s >10 years fully recovers after exposure no depends on application none/immediately stable 10 mW, adapt. time Accuracy and Uncertainty T Rotronic Accuracy Specifications: Throughout the pages of this catalog instrument accuracies are defined. Bearing in mind the explanations below, we wish to clearly explain the meaning of our specifications: H Accuracy (standard) ± 1 %RH, ± 0.3 K (at 23 ±5 °C): Based on our standard factory adjustment procedure, the instrument when compared with a reference standard such as the Rotronic AG SCS* laboratory, and within the specified temperature range, would be no more than ±1 %RH or ±0.3 K in error. Instruments with this specification are delivered with a Factory Adjustment Certificate (see page 102) E Accuracy (SCS) ±0.6 %RH, ± 0.2 K(at 23 ±5 °C): Based on an SCS* calibration, the instrument has been compared with the SCS* reference standard to provide the best possible accuracy, provided any calibration corrections are applied. For integration into an uncertainty budget, the calibration certificate defines the reference uncertainty across the instruments range. Instruments with this specification are delivered with an SCS* calibration certificate (see page 102). O * SCS – Swiss Calibration Services ROTRONIC is accredited by METAS (Metrology and Accreditation Switzerland) under the number SCS 065 R Accuracy: Y When checking the specifications of an instrument, one of the key elements that users compare is the stated ‘accuracy’. For manufacturers there is continuous pressure to state the best possible ‘accuracy’ so that their own specifications compare favorably with that of other manufacturers, or to comply with customer demands. But what does the term ‘accuracy’ really mean? In most cases, ‘accuracy’ could be defined as an instruments capability to measure a value correctly, and is usually expressed as plus or minus (±) a value or percentage. In the case of percentage relative humidity (%RH) instruments, an example would be ±1%RH over a range of 10…90 %RH (for example). This is saying that at any given point over the specified range, the instruments measurement will be no more than 1% from the true value. Accordingly, a customer can check that an instrument meets its published ‘accuracy’ specification by comparing it with a calibration standard. But this is where the situation can become more complicated, as the calibration standard itself will also have a certain ‘accuracy’. It is often the situation that manufacturers receive claims that an instrument does not meet specification, but in many cases, it can be that the calibration method itself has larger errors than the user expects. In any measurement there are always a number of factors that influence the overall measurement ‘accuracy’ and these should be defined and combined to derive a best estimate of the true measurement performance. The well established method that is used by all accredited calibration organizations world-wide is to state performance in terms of uncertainty. Uncertainty: In only a few sentences it is very difficult to explain uncertainty in any depth. The reference followed by all National Measurement Institutes (NMI) is found within standard ISO5725 (Accuracy (trueness and precision) of measurement methods and results. General principles and definitions) as well as the ‘Guide to the Expression of Measurement Uncertainty’. These define agreed methods for the presentation of measurement and calibration in terms of uncertainty instead of accuracy. In order to define an uncertainty for any measurement, all possible sources of error must be established or a best estimate made. For a %RH measurement instrument, these may include: • • • • • Calibration uncertainty (Ua) Drift (Ub) Temperature effects (Uc) Instrument resolution (Ud) Repeatability (Ue) And they would be combined to give an overall uncertainty (U) thus: U = Ua 2 + Ub 2 + Uc 2 + Ud 2 + Ue 2 ........ This is a highly simplified example of an uncertainty budget, but gives you some idea of the type of analysis and error combination that may be required. We would recommend contact with your National Accreditation body or NMI for more detailed guidance. 127 Alphabetical Index I Keyword N D Page A Accelerated water activity measurement Accessories Accessories for Agent- series Accessories for HygroLog Adaptor for pressurized air Agent-D-HT2, NT3 Air velocity probe Aw Quick function 82, 91 114 - 119 31 27 119 30 14 82, 91 BFC plate probe Bluetooth interface Bus-systems 42 21 112 - 113 C X Cable glands and mounting flanges Cable length compensation Cable probe 4 / 5 mm Calibration Calibration devices CANopen Carry cases 116 79 10, 25, 41 100 - 105 101, 117 113 116 D Damp Guard Data loggers DeviceNet Dew point probes Difgital interfaces for HygroClip Disposable sample containers HygroLab HygroLog NT HygroLog-D HygroPalm 0 HygroPalm 2 HygroPalm 3 HygroPalm AW1 HygroPalm handheld instruments HygroWin Page 82, 84 16 - 21 24 8 8 8 82, 85 8 68 I B E Keyword 1 16 - 31 113 48 67 88, 114 Industrial Hygrostat Industrial probes for HygroFlex Installation accessories and maintenance Intrinsically safeprobes 49 40 - 43 63 43 - 44 M M100-series M1-Series M22 / M23 M3-Series Mains adaptors Mating connectors Measurements in bulk products Modbus-RTU Mounting accessories M-Series transmitters 52 - 53 54 55 56 118 116 11 113 39 54 - 59 O OEM Products Options for HygroLog NT Order codesMOK adaptors 96 - 99 22 - 23 68 E Ethernet docking stations Extension / adaptor cables 22 - 23 118 - 119 F Filters 45, 114 - 115 H High performance meteorological probes High temperature probe HygroClip HK 25/HK40 HPH signal booster Humidity generators Humidity standards HVAC transmitters HW4 software functions HygroClip Alarm HygroClip HP28 penetration probe HygroClip HS28 sword probe HygroClip IC HygroClip IC04 / 05 HygroClip IC-EX HygroClip ID-EX HygroClip IE-x-EX HygroClip IM HygroClip IW-EX HygroClip probe for M-series HygroClip S HygroClip S3 HygroClip S3C03 HygroClip SC04 HygroClip SC05 HygroClip series introduction HygroClip simulators HygroClip SP05 HygroClip S-S1 HygroFlex industrial transmitters HygroFlex probe accessories 128 75 - 77 10, 25 69 103 - 104 101, 114 54 - 61 106 - 111 46 - 47 11, 26 11, 26 40 41 43 43 43 40 43 55, 56 10, 25, 55, 56, 98 66, 75, 98 77 10, 25, 87 10, 26, 87 64 - 71 35, 69, 118 11, 26, 87 10, 25, 35 - 39 45 P Paper industry instruments Pollutant table Probe extension cables Probe options and filters Profibus-DP / DPV1 12 126 118 - 119 45 113 R Roline-L Series transmitters 60 - 62 S Screw in probe SCS* humidity standards Simulators for HygroClip probes Software Standard type meteorological probe Sword probe 41 101, 114 35, 69, 118 106 - 111 76 11, 26 T Temperature adaptor for Pt100 RTD Temperature calibration in Fluorine-inert bath Temperature measuring instruments Theory 10, 94, 118 103 92 - 95 120 - 124 U Universal NTC probe USB Adaptor 30 23 V Ventilated weather shield RS-series Water Activity Water Activity Probes 72 - 74 80 - 85 86 - 87 Z Zener barrier 43, 119 How to contact ROTRONIC? ROTRONIC is a family owned group of companies with headquarters in Switzerland, and subsidiaries and distributors world-wide. Contact information can be found at www.rotronic-humidity.com. Rotronic Instruments Inc. is a subsidiary of Rotronic AG, with a team of sales, technical and support staff dedicated to humidity measurement products. Our territory includes all of North America as well as parts of Central America and South America. Te rm s a n d C o n d i t i o n s o f Tra d i n g WARRANTY If the Buyer fails to make advance payment when requested to do so by Rotronic, or if Subject to the exceptions and upon the conditions specified below Rotronic agrees to Buyer is or becomes delinquent in the payment of any sum due Rotronic, or refuses to correct, either by repair or at its election, by replacement any defects of material or work- accept C.O.D. shipments then Rotronic shall have the right, in addition to any other remedy manship which develop within one (1) year after date of shipment of the product to the to which it may be entitled in law or in equity, to cancel any Sales Order, refuse to make original Buyer by Rotronic, provided the investigation and inspection by Rotronic discloses further deliveries, and declare immediately due and payable all unpaid amounts for goods that the product had manufacturing defects. previously delivered to Buyer. Each shipment shall be considered a separate and independent transaction and payment therefore shall be made accordingly. Any product claimed to be defective must, if requested by Rotronic, be returned to the How to contact us: factory, transportation charges prepaid, and will be returned to Buyer with the transpor- SHIPMENTS tation charges collect. Products found by us to have any manufacturing defects will be Buyer is obligated to verify that any shipment corresponds to the packing slip. Shipments returned without charge to the Buyer, method of return to be determined by Rotronic. that show any shortages or discrepancy have to be reported in writing and returned in full to Rotronic within a period of ten (10) days from receipt of such shipment by the buyer Rotronic Instrument Corp. 160 E. Main Street Huntington, NY 11743 Rotronic shall be released from all obligations under all warranties either expressed or thereof. In the case a shortage or discrepancy claim is made, Rotronic’s sole liability is implied, if any product covered hereby is repaired or modified by persons other than its limited to correcting the shipment or refunding the Buyer if no correction can be made own authorized service personnel. unless such repair by others is made with the written within reasonable time. After expiration of the ten (10) day period, Rotronic will not be consent of Rotronic or unless such repair in the sole opinion of Rotronic is minor or unless responsible for any shortage or discrepancy and the shipment will be deemed to be con- such modification is merely the installation of a new Rotronic plug-in component for such forming to the packing slip. product CANCELLATION AND RESTOCKING CHARGES 800-628-7101 631-427-3902 Our Service to You ROTRONIC MAKES NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF Orders may not be cancelled and shipments returned without Rotronic’s written accep- THE PRODUCTS COVERED HEREBY OTHER THAN AS EXPRESSLY STATED HEREIN, tance and payment of a charge by the Buyer. Cancellation and restocking charges will be • Competitive prices ROTRONIC EXPRESSLY AND SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTY OF based on the cost, including engineering, drafting, materials, labor and sales work incur- MERCHANTABILITY AND MAKES NO WARRANTY WITH RESPECT TO THE FITNESS OF red by Rotronic. If cancellation or return is approved by Rotronic, the following will apply: • High quality products ANY PRODUCT COVERED HEREBY FOR ANY PARTICULAR PURPOSE OR USE UNLESS • ISO9001 production quality system • Comprehensive 12 month warranty [email protected] • Dedicated team, specializing in humidity SUCH A WARRANTY IS EXPRESSLY SET FORTH. 1) Minimum charge of 25% of sales price, prior to any discount, if order is not in manufacturing or if return concerns standard products in quantities of no more than ten (10) units. THE BUYER OR ANYONE CLAIMING UNDER ANY WARRANTY RELATING TO PRODUCTS 2) Minimum charge of 50% of sales price, prior to any discount, if order is in manufacturing SOLD HEREUNDER AGREES THAT IF ROTRONIC BREACHED ANY SUCH WARRANTY, or if return concerns non-standard products or standard products in quantities of more OR ANY WARRANTY IMPLlED EITHER IN FACT OR BY OPERATION OF LAW, OR IF ANY than ten (10) units. PRODUCTWARRANTED HEREUNDER PROVES DEFECTIVE IN ANY MANNERWHATSOEVER, ROTRONIC SOLE LIABILITY HEREUNDER IS LIMITED TO EITHER REPLACEMENT OF ANY DELIVERY DEFECTIVE PRODUCT OR AT THE, OPTION OF ROTRONIC, REFUNDING TO THE BUYER The scheduled shipping or delivery date is our best estimate of the time the order will be THE PURCHASE PRICE PAID FOR SUCH DEFECTIVE PRODUCT. THE BUYER AND ANYONE shipped and Rotronic assumes no liability for loss, general damages, or special or conse- ELSE CLAIMING UNDER ANY WARRANTY RELATING TO PRODUCTS SOLD HEREUNDER quential damages due to delays. EXPRESSLY AND SPECIFICALLY AGREE THAT ROTRONIC IS NOT RESPONSIBLE FOR, www.rotronic-usa.com AND THE BUYER OR SUCH OTHER CLAIMANT OR CLAIMANTS SHALL ASSUME, ANY TAXES AND DUTIES LIABILITY FOR PROPERTY DAMAGE, PROSPECTIVE PROFITS, SPECIAL, INDIRECT, OR Federal, state or local excise, sales or use taxes shall be paid by Buyer. Buyers claiming CONSEQUENTIAL DAMAGE, OR OTHER COMMERCIAL OR ECONOMIC LOSS ARISING OUT tax exemption are responsible for providing Rotronic with all legally required documents OF USE OR POSSESSION OF ANY PRODUCT SOLD HEREUNDER. ROTRONIC SHALL NOT and statements. Import duties and any other charges shall be paid by Buyers outside of BE LIABLE FOR, AND A BUYER OR ANYONE ELSE CLAIMING UNDER ANY WARRANTY the United States. RELATING TO PRODUCTS SOLD HEREUNDER FURTHER AGREES, AND SHALL ASSUME, ANY LIABILITY FOR PERSONAL INJURY ARISING OUT OF USE OR POSSESSION OF ANY PATENTS PRODUCT SOLD HEREUNDER. Rotronic agrees to defend any suit or proceeding brought against Buyer so far as based upon an assertion that any product, or any part thereof, sold under a Sales Order consti- Buying from ROTRONIC INSTRUMENTS Contact our experienced sales team for product and application advice, current pricing and availability. Our field sales team offer on-site application consultancy and product technical support throughout the United States. Core products can be purchased on-line at www.rotronic-usa.com Terms and conditions of trading see page 129. If a Rotronic Special Warranty covering a designated item or items is attached hereto the tutes a direct infringement of any United States patent having a claim or claims covering terms and conditions specified therein are incorporated herein by reference and shall solely the product itself, or any part thereof, or the normal use for which such product or supplement this warranty, in the event of a conflict between the terms and/or conditions part was designed, if notified promptly in writing and given authority, information and specified herein and those specified in such Special Warranty, the terms and/or conditions assistance (at Rotronic expense) for the defense of same, and Rotronic shall pay all da- of the Special Warranty shall control. mages and costs awarded therein against Buyer. If said product, or any part thereof, is in such suit held to constitute infringement and the use of said product or part is enjoined, Representations and warranties made by any person, including dealers and represen- Rotronic shall at its own option and at its own expense either (I) procure for Buyer the right tatives of Rotronic. which are inconsistent or in conflict with the terms of this warranty to continue using said product or part, (II) replace the same with a non-infringing product (including but not limited to the limitations of the liability of Rotronic as set forth above), or part, (III) modify it so it becomes non-infringing, or (IV) remove said product or part and shall not be binding upon Rotronic unless given in writing and approved by an expressly refund the purchase price and transportation costs thereof. The foregoing obligations of authorized representative of Rotronic. Rotronic shall not apply to any infringement claim based upon (I) any use of any product sold hereunder in any process (other than a process carried out by such product as an PRICES inherent function of such product or in conjunction with any other product (unless such The prices set forth are based upon the manufacture of the quantity and type ordered other product is an accessory especially designed and sold by Rotronic for use with the and are subject to revision when interruption, engineering changes or changes in quantity product sold hereby) or (II) any product manufactured to Buyer’s design or any product Warranty or quality are caused or requested by Buyer. Prices do not include warranty service or having a design arising out of compliance with Buyer’s specifications. The foregoing states installation outside the United States and Canada. Clerical errors made by Rotronic are the entire liability of Rotronic for patent infringement by said product. All ROTRONIC products now have a 1 year warranty. subject to correction. Service and Calibration Our technical support team offer a wide range of services including repairs, calibration and service contracts. Contact [email protected]. LIMITATION OF ACTIONS SPECIFICATIONS No action, shall be brought for any breach of this contract more than one (1) year after the Weights and dimensions set forth in sales literature are not guaranteed unless previously accrual of the cause of action therefore. certified in writing. Rotronic may, without affecting the obligations under a Sales Order, make insignificant changes in the specifications of the product or products delivered under ACCEPTANCE the Sales Order from those contained in sales literature. No acceptance of the terms and conditions of this sale shall be effective which varies the terms hereof or proposes additional terms. Any such proposals shall be deemed rejected TERMS OF PAYMENT unless expressly approved by Rotronic Terms of payment are net thirty (30) days from date of the invoice unless otherwise specifically stated. Invoices are payable at par on date due at any place of collection designated APPLICABLE LAW by Rotronic in funds bankable. All orders are accepted subject to and the obligation of This contract shall be governed and construed in accordance with the law of the State of Rotronic to make deliveries is subject to, the right of Rotronic to require of Buyer payment New York. The venue for any action arising out of this agreement shall be Suffolk County, of all or any part of the purchase price in advance of delivery or to make shipment C.O.D. New York. FEUCHTE- UND TEMPERATURMESSUNG 2006/2007 Einsteinstrasse 17- 23 D-76275 Ettlingen Telefon +49 7243 383 250 Fax +49 7243 383 260 www.rotronic.de 2005/ 2007 Grindelstrasse 6 CH-8303 Bassersdorf Telefon +41 44 838 11 44 Fax +41 44 837 00 73 www.rotronic.com 56, bd Courcerin, Bat. 44 77183 Croissy Beaubourg, France Téléphone +33 1 60 95 07 10 Fax +33 1 60 17 12 56 www.rotronic.fr 160, East Main Street Huntington N.Y. 11743, USA Telephone +1 631 427 38 98 Fax +1 631 427 39 02 www.rotronic-usa.com 2B, Zao Fong Universe Building No. 1800 Zhong Shan West Road Shanghai 200233, China Telephone +86 21 644 03 55 Fax +86 21 644 03 77 www.rotronic.cn FEUCHTE- UND TEMPERATURMESSUNG Unit 1A Crompton Fields Crompton Way Crawley, West Sussex RH10 9EE Telephone +44 1293 571000 Fax +44 1293 571008 www.rotronic.co.uk