Acandis® Acclino® 1.9F Stent System

Transcription

Acandis® Acclino® 1.9F Stent System
Acandis® Acclino® 1.9F Stent System
1.9F self-expanding stent system
for aneurysm neck bridging
} Suitable for vessel diameter range 2 – 4 mm
} Retrievable and repositionable up to 90% of its deployment
} Conformable and flexible closed cell design optimized for curved vessels
} Low profile radiopaque gold markers
Set includes ultra low profile Acandis® 1.9F Microcatheter
with dual markers for stent placement and coil delivery
ENGINEERING STROKE SOLUTIONS
1275
Acandis GmbH & Co. KG
Theodor-Fahrner-Str. 6
75177 Pforzheim/Germany
Tel.: +49 7231 155 00 0
Fax.:+49 7231 155 00 129
www.acandis.com
Acandis® Acclino® 1.9F Stent System
TECHNICAL SPECIFICATIONS
Stent diameter / length:
3.5, 4.5 mm / 15, 25, 35 mm
Microcatheter outer / inner diameter:
1.9F / 0.0165“
Microcatheter usable length:
155 cm
Guidewire (recommended):
0.010” – 0.014“
Guiding catheter (recommended):
5F
Stent system features
Stent
Indicator for correct expansion
and positioning: 3 distal stent markers
Indicator for correct expansion
and positioning: 3 proximal stent markers
Transport wire
Atraumatic soft tip:
Indicator for correct positioning:
Indicator for release limit:
Distal marker (Highly flexible)
Middle marker
Proximal marker
_________________________________________________________________________________________________________________
Microcatheter features
Dual layer hydrophilic coating (100cm)
_________________________________________________________________________________________________________________
Ordering information
Stent length (mm)
01-000066
01-000067
01-000068
01-000069
01-000070
01-000071
15
25
35
15
25
35
Stent diameter (mm)
IMPORTANT INFORMATION: The Acandis® Acclino® 1.9F Stent
system is tested for compatibility with the included Acandis® 1.9F Microcatheter ONLY. Prior to use, refer to IFU supplied with the device
for indications, contraindications, side-effects, suggested procedure,
warnings and precautions. Acandis reserves the right to change
product specifications without prior notice.
ENGINEERING STROKE SOLUTIONS
Acandis GmbH & Co. KG
Theodor-Fahrner-Str. 6
75177 Pforzheim/Germany
Tel.: +49 7231 155 00 0
Fax.:+49 7231 155 00 129
www.acandis.com
Recommended vessel diameter (mm)
3.5
> 2.0 ≤ 3.0
4.5
> 3.0 ≤ 4.0
DISTRIBUTED BY:
1275
09-000029 EN 07/2012
01
Reference number