Making Sizing Easier
Transcription
Making Sizing Easier
SV s G the only self-apposing® stent LAR G E SSELS VE NEW Indications NEW Results in STEMI BIFUR C A N IO T ECTATIC V E LS SE S PERING V A ES T S EL S MAKING SIZING EASIER... MAKING SIZING EASIER... Which stent size? 3.0? 3.5? 3.0 3.5 Malapposition, Underexpansion Overdilation Stent thrombosis Restenosis Dissection/ Perforation No reflow THE SELF-APPOSING® STENTYS BMS & DES(P) STENTS 1 One stent size provides a range of vessel diameters making sizing easier when the actual diameter is obscured (eg. in STEMI) 2 The stent adapts itself to the shape of the natural artery and can expand to different diameters at distal and proximal points, so is well-apposed to tapering vessels or aneurysms 3 The stent has disconnectable interconnections between struts which create access to the sidebranch if required. 4 The stent can continue to expand after deployment in case of vasodilation, thrombus resolution or positive remodelling over time CHOOSE THE SELF-APPOSING ® STENT! APPOSITION III REGISTRY - 1 YEAR RESULTS IN 965 STEMI PATIENTS1 20 Cumulative event rate (%) Cardiac Death at 1 year MACE at 1 year 18 16 8% 14 7% 12 6% MACE : 9.3% 10 5% 8 3.9 % 4% 6 3% Cardiac death or TV-MI : 3.2% 4 2.0 % 2% 2 Cardiac death : 2.0% 1% 0 R O E E X H A M IN Time since STENTYS placement (months) P A S 12 O 10 N 8 M 6 A T IO 4 K O 2 E BMS / DES use in population: 74% / 26% M R U IZ LT O IS N T S R A T E G O Y N -T IM E 2 TA P A T S Y P H O O N P A S W S ei IO gh N te d m ea n A P P O S IT IO N III 0% 0 Importance of Post-Dilatation* Results at 1 year With post-dilatation Without post-dilatation P-value Cardiac death/TV-MI 2.4% 5.0% 0.03 Definite Stent Thrombosis 1.9% 5.0% 0.01 * ONLY 2.4% CARDIAC DEATH /TV-MI AT 1 YEAR WHEN POST-DILATATION WAS PERFORMED DEPLOYING A STENTYS STENT 1 The Self-Apposing® STENTYS Stent is positioned over the lesion before deployment. 2 The STENTYS Stent is deployed from distal to proximal by retracting the outer sheath. 3 The STENTYS Stent is fully deployed in the artery of the patient. Post-dilatation is recommended to ensure adequate stent expansion. OPTIONAL DISCONNECTION AT A SIDEBRANCH 1 Position the guidewire into the side-branch through the stent cell closest to the carina. 2 Inflate a regular PTCA balloon at low pressure (8atm) at the side-branch opening to disconnect the struts. 4 The STENTYS Stent expands with the vessel during vasodilation and as thrombus resolves. Only 3.7% TLR at 6 months in bifurcations2 3 Stent interconnectors separate due to the combined effect of flexion and torsion created by the balloon. 4 Deflate and withdraw the 1. Pooled analysis by the ACTION study Group at Pitié-Salpêtrière Hospital (www.action-coeur.org - Prof. G. Montalescot) 1 year results presented at ACC.13 by Prof. Gilles Montalescot 2. Results of DES(P) arm in OPEN I trial - S. Verheye et al., Eurointervention 2011;7:580-587 balloon allowing the stent to expand fully. This creates an opening to the side- branch. Final kissing balloon is not required. STENTYS BMS and DES(P) ORDERING CODES BMS THE SELF-APPOSING Indicated Vessel TM DES (P) STENT T H E S E L F - A P P O S I N G TM S T E N T Stent nominal length Diameter (mm) 17mm Side-branch Stent nominal length 22mm 27mm 17mm 22mm 27mm diameter (mm) ≥ 2.20 2.5-3.0 (Small) STY00-2530-17 STY00-2530-22 STY00-2530-27 STY01-2530-17 STY01-2530-22 STY01-2530-27 3.0-3.5 (Medium) STY00-3035-17 STY00-3035-22 STY00-3035-27 STY01-3035-17 STY01-3035-22 STY01-3035-27 ≥ 2.25 3.5-4.5 (Large) STY00-3545-17 STY00-3545-22 STY00-3545-27 STY01-3545-17 STY01-3545-22 STY01-3545-27 ≥ 2.50 SELF-APPOSING® TECHNOLOGY* B A D C 145cm * Indicated vessel diameter ** Approximate length when expanded at indicated vessel diameter A - The STENTYS Stent is a self-expanding, nitinol, bare-metal or drug-eluting (Paclitaxel) stent. B - The catheter is a rapid-exchange, single-wire system with hydrophilic coating. C - Guidewire compatibility: 0.014’’ (0.35mm). Guiding catheter compatibility: 6F (2.0mm). D - Deployment handle with retractable trigger. Strut width: 68µm (0.0027’’) Stent recoil: 0% *Technical data from STENTYS DISCONNECTION TECHNOLOGY The Self-Apposing® STENTYS Stent has disconnectable interconnections between struts which create access to the sidebranch if required. Disconnectors along the stent Disconnector Disconnection The STENTYS stents are CE marked when intended for improving coronary luminal diameter in the treatment of ACS, de novo lesions, in vessels involving a sidebranch (bifurcation) or with diameter variations (e.g. tapered ectatic), in native coronary arteries and coronary bypass grafts (CABG). CAUTION: Indications, contraindications, warnings and instructions for use can be found in the product leaflet supplied with the device. Not available for sale in the United States. © STENTYS S.A. 2013 STENTYS S.A. 25, rue de Choiseul 75002 Paris France Tel: +33 1 44 53 99 42 Fax: +33 1 44 53 99 24 STY-SIZ-130514 www.stentys.com