Giunti e Terminali di Media Tensione CELLPACK
Transcription
Giunti e Terminali di Media Tensione CELLPACK
Medium Voltage D813 | SAP.Nr. 198693 | 1112 Catalogue 2013 Data, values and illustrations given in this documentation are correct and reliable according to the current state of our knowledge. They represent however no obligatory characteristic warranty. Such a warranty is made only by our product standards. The user of this product must decide on his own responsibility on its suitability for the intended application. Our liability for these products exclusively depends on our general trading conditions. Changes in the sense of technical progress and misprint reserved. © 2013, CELLPACK GmbH. All Rights Reserved. Safe connections www.cellpack.com 2 www.cellpack.com Medium Voltage 2013 Medium Voltage 2013 Page Introduction | Cellpack Technology 4 Cable accessories for unscreened cables 24 Cable accessories for screened cables 30 Cable accessories for paper-insulated cables 70 Cable accessories for screened cables according to British Standard 90 Cable accessories for the industries 102 Accessories 106 Index 136 www.cellpack.com 3 Introduction Medium Voltage 2013 Cable accessories are indispensable components of a cable network which exert a direct influence on its quality. The same level of operational safety must be guaranteed for the accessories as for the cable itself. Due to high operational costs incurred by medium voltage networks, it is necessary to avoid outages. The safe, quick and easy assembly of cable accessories is therefore essential for network reliability. Exceptional innovative solutions are thus required to ensure that excessive demands are not placed on the capabilities of assembly staff. We produce innovative, high-performance cable accessories for medium voltage networks based on the stress control system developed by Cellpack. Cellpack Villmergen | Switzerland Cellpack Tiengen | Germany Cellpack Radeberg | Germany We offer a full range of products for a wide variety of applications using heat shrink, silicone, slip-on, plug-in and cast resin technologies which comply with the standard requirements for energy suppliers and the set industrial norms. The system components of all of our cable accessories are compatible so as to ensure safe and reliable functioning. As a result of intensive testing carried out in our laboratories, as well as numerous type tests carried out in international test facilities, we are able to guarantee an operationally reliable conductor connection, an adequate insulation level and excellent resistance against all environmental influences for all our cable accessories. All our medium voltage products are tested according to DIN VDE 0278, CENELEC HD 629.1, HD 629.2, IEC 60502-4 and comply with IEEE and BS requirements. Cellpack Almere Buiten | Netherlands Cellpack Warschau | Poland Cellpack Ludres | France Cellpack Barcelona | Spain Cellpack Melaka | Malaysia Cellpack Singapur | Far East 4 www.cellpack.com Medium Voltage 2013 Removal of the cable insulation and the outer semi-conducting layer when connecting or terminating medium voltage cables results in damage to the cable structure. In addition to this, the electric field becomes strongly inhomogeneous at particular points. During this process the electric field strength value greatly increases, resulting in a risk of partial discharge, breakdown or spikes. Stress control influences the strong inhomogeneous field distribution at the cable end so as to reduce the high field strengths to a non-critical value. Refractive stress control is the most suitable method for medium voltage cable accessories. It offers the following significant advantages over other methods: • Leaner stress control element design, enabling the development of compact solutions which are very easy to assemble. • Reduced sensitivity to incorrect positioning or incorrect cable preparation, allowing compensation for errors made during assembly. Refractive stress control Refractive stress control influences the electric field by means of a combination of two insulation materials having different dielectric strengths. The insulation material with the higher dielectric constant is placed in the area at which the higher electrical field strength occurs. The use of the term „refractive“ derives from the fact that the process deflects electric field lines which cross the surface of these materials at an angle(see Figure 1). (Fig. 1: Interruption of electric field lines at the point of transition between materials with different dielectric constants) www.cellpack.com 5 Cellpack Technologie Stress control in MV cable accessories Medium Voltage 2013 Cellpack Technologie When using the above principle in medium voltage cable accessories, a thin stress control and insulation layer is placed in the region above the strippable edge of the outer semi-conducting layer (for cables with plastic insulation), or above the Hochstädter foil or lead sheath (for cables with paper insulation), or above the core insulation when the cable insulation has been removed. This layer has a considerably higher dielectric constant (εr) than the insulating material of the cable itself. This results in a targeted reduction of the original field strength (see Fig. 2). (Fig. 2: Comparison of lines of equipotentiality in a plastic-insulated cable with the insulation removed, with and without refractive stress control). Stress control element (FSE) In addition to stress control itself, the positioning of the contact surfaces of cable insulation and accessory during assembly is very significant. Trapped air can result in partial discharge even at low voltages, particularly in the area of stress control, resulting in the breakdown of the cable accessory. In order to avoid these problems, we have developed a stress control element (FSE) made from a special silicone rubber, manufactured using injection-moulding. This product owes its uniqueness to its optimised design and to the specific properties of the HTV silicone rubber used. The dimensions of the cylinder body have been carefully selected to ensure that a single stress control element size is compatible with a wide range of medium voltage cable cross-sections. The dimensions of the inner cylindrical area allow the positioning of the FSE on the smallest possible cross-sectional area, where it expands to the correct size, thus exerting a permanent contact ressure on the base. The permanent high elasticity of the silicone ensures that a constant pressure is applied to the contact surface under all operating conditions. The high gas permeability of the special material constitutes a significant advantage. As a result of constant pressure on the contact surface, pockets of air arising during assembly will completely diffuse through the stress control material within a few minutes (Fig. 3). This protects the cable accessory against partial discharge under all operating conditions. (Fig. 3 Disappearance of an air bubble in the gap between the sleeve insulating body and the FSE) 6 www.cellpack.com Medium Voltage 2013 Cellpack Technologie Stress control elements can be slid over any cable safely, quickly and easily with the aid of the AH slip-on auxiliary device patented by Cellpack. The slip-on auxiliary device has been designed so as to prevent damage to the inner cylindrical surface of the stress control element during assembly. www.cellpack.com 7 Medium Voltage 2013 Cellpack Technologie Hybrid technology Hybrid technology is a modular system developed by Cellpack which combines components made from silicone rubber with high voltage resistant heat shrink products. This renders our cable accessories compatible with all existing medium voltage cable cross-sections and ensures maximum operational reliability. The full product range comprises plug-in straight-through and transition joints, indoor and outdoor terminations for single- and three-core cables, which comply with the standard requirements for energy suppliers and the set industrial norms. We also offer products based on customer specifications. Advantages Our hybrid cable accessories offer a high level of operational safety in addition to the following advantages: • Safe, quick and easy installation • Compact and space-saving • Unlimited shelf life • Adaptability 8 www.cellpack.com Medium Voltage 2013 The main insulation material used in hybrid plug-in straight-through and transition joints consists of a combination of heat-shrink tubing supplied in telescoped form. The insulation materials are manufactured from high-performance polymeric materials with appropriate additives. The resulting joint system can be positioned and heat-shrunk onto the cable cores to be connected from the park position during assembly safely, quickly and easily. The dimensions of the tube are selected to ensure a defined insulation wall thickness for the appropriate voltage level and cable cross-section. Stress control is achieved by slipping the silicone rubber stress control elements onto the prepared cable end using the patented slip-on auxiliary device. A special filling tape possessing exceptionally high dielectric strength and oil-resistant properties is used to restrict the field strength around the connectors and to prevent air pockets. Assembly is safe, quick and easy, due to the compatibility of all system components. Diagram of type CHMSV straight-through joint: Connector 1. 2. Field control tape 3. Joint insulation 4. Stress control element 5. Screen continuity 6. Outer sheath Cable screen continuity for single-core cables is achieved in accordance with current standards by means of a copper braid sleeve, which is connected to the copper wire and/or tape screen using pressure springs. Other types of shielded connections are available upon request. A heat- shrink tube with integrated hot-melt adhesive developed especially for the outer sheath and possessing very high mechanical strength guarantees a reliable seal. www.cellpack.com 9 Cellpack Technologie Hybrid joint system Medium Voltage 2013 Hybrid termination system Cellpack Technologie Stress control within cable terminations is achieved in the same way as for the hybrid joint system- by simply slipping the tried and tested silicone rubber stress control elements onto the cable end, using the patented slip-on auxiliary device. A sealing tape- another well-established product- is wrapped around the cable shielding and the cable lug to provide a reliable seal. A heat-shrink spreader cap with integrated heat-sealing adhesive provides a reliable seal for the connector distributor and the cable sheath in the distribution region of three-core cables. The main insulation material used in terminations is heatshrink tubing, which is manufactured from high-performance tracking resistant polymeric materials. To establish the necessary creepage distances, highly-elastic shields manufactured from tracking resistant silicone rubber are installed on the tubing after shrinking. Once again, the use of the patented slip-on auxiliary device ensures safe, quick and easy assembly. Diagram of type CHE termination: 1. Cable lug 2. Seal 3. Stress control element 4. Leakage current-resistant outer tube 5. Leakage current-resistant silicone shield 10 www.cellpack.com Cellpack Technologie Medium Voltage 2013 The exceptional hydrophobic properties, resistance to leakage current and high elasticity of silicone rubber guarantee sustained operational safety. All materials characterised by exceptionally high resistance to ozone and UV radiation have undergone decades of rigorous testing under challenging climatic conditions and have proven themselves in innumerable installations all over the world. Standard hybrid terminations are designed for challenging climatic conditions and comply with CENELEC and IEC 60816 requirements. www.cellpack.com 11 Medium Voltage 2013 Contrax technology Cellpack Technologie All primary components of our Contrax technology system are integrated into a single-piece insulating body. This reduces the number of cable accessory components, greatly simplifying assembly. Its compact, optimised design reduces the associated assembly, storage and transportation costs to the energy supplier. Insulating bodies for joints and terminations are manufactured from high-voltage resistant silicone rubber using a controlled injection process. Rigorous quality control as well as high-voltage component testing during production ensures the technical reliability of all our Contrax cable accessories. Advantages Our Contrax cable accessories offer a high level of operational safety in addition to the following advantages: 12 • • • • • www.cellpack.com Safe, quick and easy installation Systems available for all cross sections Compact and space-saving Unlimited shelf life Adaptability Medium Voltage 2013 The single-piece insulating body of Contrax plug-in straight-through joints consists of an inner conductive electrode which acts as a Faraday cage around the connector with the main insulating layer above it, and an outer semi-conducting layer. Each joint body comes equipped with an integrated slip-on auxiliary device for easy assembly and the prevention of damage during installation. Diagram of CAM joint body: 1. Connector 2. Single-piece insulating body 3. Stress control element 4. Screen continuity 5. Outer sheath Stress control at the cable end is achieved as above, by simply sliding our tried and tested silicone rubber stress control element onto the prepared cable using the patented slip-on auxiliary device. A special feature of the Contrax joint is that the stress control element is also used to control the electric field on the inner semi-conducting layer of the insulating body at high voltage against the outer semi-conducting layer of the joint body at earth potential. Electric field strength and lines of equipotentiality of type CAM Contrax straight-through joints. www.cellpack.com 13 Cellpack Technologie Contrax joint system Medium Voltage 2013 Cellpack Technologie The resulting lean and compact design of the joint body has proven to be particularly suited to use in three-core cables, as the joint body can be placed on the prepared core insulation in park position in a safe and simple process. Cable screen continuity is achieved using a copper braid sleeve which is easily connected to the copper wire and/or tape screen using highly-elastic pressure springs. Other types of shielded connections are available to order. Special outdoor protection systems for Contrax plug-in straight-through joints are based on cast resin technology, thus ensuring a reliable seal and high mechanical strength. 14 www.cellpack.com Medium Voltage 2013 Contrax terminations consist of a single-piece insulating body manufactured from a creepage tracking resistant silicone rubber using a quality-controlled injection moulding process. The stress control element and necessary shields are also integrated into the insulating body. The compact optimised design minimises assembly, storage and transportation costs to energy suppliers. The silicone rubber used is characterised by excellent resistance against ozone and UV radiation, as well as exceptional hydrophobic properties. Its unique design has undergone years of rigorous testing under challenging climatic conditions. Contrax terminations are designed for challenging climatic conditions and thus comply with CENELEC and IEC 60815 requirements. Diagram of type CAE termination: 1. Cable lug 2. Seal 3. Single-piece insulating body with integrated stress control element Construction of Contrax terminations Hydrophobic properties of the silicone used www.cellpack.com 15 Cellpack Technologie Contrax termination system Medium Voltage 2013 Cellpack Technologie Assembly is carried out in a single-step process, in which the single-piece body is safely, quickly and easily slid onto the prepared cable end using the patented slip-on auxiliary device. A silicone spreader cap using special cold-shrink technology, patented by Cellpack, and silicone tubes with an integrated slip-on auxiliary device are used in the distribution region of three-core cable, ensuring simple and accurate assembly. A special sealing tape provides a reliable seal at the cable shielding and around the cable lug. 16 www.cellpack.com Medium Voltage 2013 Plug-in technology Cellpack Technologie Plug-in technology consists of four components- the conductor connection, main insulation, stress control element and outdoor protection system- which are combined to form a single element. This integrated system developed by Cellpack maximises the reduction of assembly, storage and transportation costs to energy suppliers. Compax and Cellplux plug-in connection technologies are the result of over 5 years of work in product development and constitute a perfect connection system for medium-voltage networks. • Can be installed safely, quickly and easily • Systems available for all cross sections • Integrated system components • Compact and space-saving • Unlimited shelf life • Tested and approved in accordance with CENELEC HD 629.1 Comprehensive quality control carried out in accordance with ISO 9001 as well as electrical component checks during production ensure the technical reliability of all our plug-in cable accessories. www.cellpack.com 17 Medium Voltage 2013 Compax plug-in straight-through joint Cellpack Technologie This joint has been especially developed for connecting plastic-insulated medium voltage single-core cables. All system components are compatible to ensure that assembly is extremely safe, quick and easy. This innovative integration concept allows for much of the assembly process, previously carried out on-site, to be performed under controlled conditions and subjected to electrical testing at the Cellpack factory. Only a few assembly steps remain to be performed on-site. Advantages: • • • • • • • 18 Safe, quick and easy assembly Only standard tools required Suitable for use in confined spaces Products available for all cross sections Robust design Reduction in storage and transportation costs Unlimited shelf-life www.cellpack.com Medium Voltage 2013 The insulation materials in the CKM joint are equipped with exceptional electrical and mechanical properties and are manufactured from high voltage- resistant silicone rubber in a controlled injection moulding process. Each individual material component has been subjected to years of extensive electrical and mechanical testing and has proven its reliability over decades of application. 7 6 1 2 3 4 5 Diagram of type CKM straight-through joint 1. Screw connector 2. Joint insulation 3. Insulating support 4. Stress control element 5. Screen continuity 6. Outer sheath 7. Seal Integrated screw connector A unique feature of the Compax connection system is that the insulating body of the joint comes equipped with a tried and tested integrated screw connection system. This screw connector is compatible with all cross-sections and has been designed to guarantee a reliable connection for both copper and aluminium conductors. The optimised design of the contact screws allows the use of a single standard tool for all cross-sections. Integrated field control The CKM joint insulation body comes equipped with the Cellpack refractive stress control system, a device which has been used time and time again by our customers all over the world. This permits the reduction of assembly errors due to poor cable preparation or incorrect positioning of the joint body. Stress control in the connector screw openings is achieved geometrically. www.cellpack.com 19 Cellpack Technologie Insulation materials Medium Voltage 2013 Cellplux plug-in connectors Cellpack Technologie Cellplux plug-in cable connection components have been especially developed to connect plasticinsulated medium voltage cables. All system components are compatible to ensure that assembly is extremely safe, quick and easy. This innovative integration concept allows for much of the assembly process, previously carried out on-site, to be performed under controlled conditions and subjected to electrical testing at the Cellpack factory. Only a few assembly steps remain to be performed on-site. Advantages: Cellplux plug-in cable connection components guarantee reliable operational safety and offer the following advantages: • • • • • • • 20 High level of operational safety Safe, quick and easy assembly Standard tools may be used Suitable for use in confined spaces Products available for all cross sections Robust design Unlimited shelf life www.cellpack.com Medium Voltage 2013 Insulation materials used in Cellplux plug-in cable components possess exceptional electrical and mechanical properties and are manufactured from high voltage resistant EPDM using a controlled injection moulding process. Stress control is achieved by means of the silicone stress control element, offering all the above-mentioned advantages. Each individual material component has been subjected to years of extensive electrical and mechanical testing and has proven its reliability over decades of application. 1. 2. 3. 4. 5. 6. 7. 8. Silicone stress control element Screw-in cable lug with shear bolt screw and integrated bracket Contact bolts with shear bolt screw Inner electrode Main insulation Shielding Screw-in insulating supports with capacitive test point Protective cap www.cellpack.com 21 Cellpack Technologie Insulating materials Medium Voltage 2013 Cellpack Technologie Screw-in cable lug and screw-in contact bolts Cellplux plug-in cable components are equipped with a tried and tested screw-in cable lug system, compatible with all cross-sections, which has been designed to guarantee reliable connection for both copper and aluminium conductors. The optimised design of the contact bolts permits the use of a single Monventional tool for assembly across the entire range of cross sections. The shear bolt screw system is also used for CTS screwtype plug-in connection contact bolts connecting the cable lug to the connecting terminal. This eliminates the possibilty of errors during assembly. Stress control This system is also equipped with Cellpack’s integrated refractive stress control system, which has a proven track record of reliability. This eliminates the possibility of incorrect cable preparation and dramatically reduces the number of possible assembly errors. Protection from exposed electrical parts Cellplux plug-in cable component shieldingaa is made from conductive EPDM rubber over 3mm thick. All products have successfully undergone tests for insulation failure detection. 22 www.cellpack.com Medium Voltage 2013 Quality system Cellpack Technologie All production sites have been certified according to ISO 9001, 2008 revision and ISO 14001, 2004 revision. www.cellpack.com 23 For pros by pros 24 www.cellpack.com Medium Voltage 2013 Medium Voltage 2013 Cable accessories for unscreened cables Page Straight-through joints 26 Terminations 28 www.cellpack.com 25 Straight-through joints Medium Voltage 2013 SMH3MS6 Three-core straight-through joint for armoured 3-core polymeric cables without semi-conducting layer up to 7.2 kV Type SMH3MS6 straight-through joints are suitable for three-core plastic-insulated cables (PVC, PE, XLPE, EPR) with no outer semi-conducting layer. They allow the connection of cables with different cross sections, conductive materials and structure. Dimensions Cable accessories for unscreened cables L = Length Characteristics • Compact dimensions • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation • High mechanical strength L mm Type Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Connectors not included max. Ø of connector mm U0/U (Um) 3.6/6 (7.2)kV - 3.8/6.6 (7.2)kV 25-70 MS6 850 20 1000 25 SMH3 50-150 MS6 120-300 MS6 1200 40 Appropriate connectors must be ordered separately. 26 www.cellpack.com Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Inner jacket sleeve • Copper braid tube • Pressure spring • Assembly instructions max. connector length mm 110 135 150 Nominal cross section Art.-No. mm² 25 - 70 50 - 150 120 - 300 145630 145633 145635 Straight-through joints Medium Voltage 2013 M...MS6 Three-core straight-through joint for armoured 3-core polymeric cables without semi-conducting layer up to 7.2 kV Type M.MS6 straight-through joints are suitable for three-core plastic-insulated cables (PVC, PE, XLPE, EPR) with no outer semi-conducting layer. They allow the connection of cables with different cross sections, conductive materials and structure. They do not contain any substances which inhibit paint wetting and are suitable for use in the automotive industry. Dimensions Characteristics • Quick, safe and easy assembly • Resistant to chemical agents • Longitudinally and transversely watertight • High mechanical strength Type U0/U (Um) M4 MS6 M5 MS6 M6 MS6 Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Connectors not included Nominal L1 L2 D1 D2 D3 Cable-Ø cross section mm mm mm mm mm mm² 3.6/6 (7.2)kV - 3.8/6.6 432 384 29 52 550 503.2 40 62 660 600 50 78 (7.2)kV 90 29 - 55 110 42 - 65 145 50 - 78 25 - 70 95 - 120 150 - 240 Scope of delivery • Distance sleeve • Hydrolysis resistance PUR type EG cast-resin, containing the correct volume ready for mixing. Packed in practical and easy-to-use two chamber bags • Transparent plastic moulds • Copper braid tube • Hose clamp • Fill and air-release funnel • PVC insulation tape • Protective gloves • Assembly instructions concentric conductor nominal cross section per conductor mm² Art.-No. 25/25 - 50/50 70/70 - 95/95 120/120 - 185/185 124318 124319 124320 Appropriate connectors must be ordered separately. www.cellpack.com 27 Cable accessories for unscreened cables L = Length D = Diameter Terminations Medium Voltage 2013 SEEV Three-core indoor termination for armoured 3-core polymeric cables without semi-conducting layer up to 7.2 kV Terminations Type SEEV for indoor applications are suitable to cover armoured three-core polymeric cables (PVC, PE, XLPE, EPR) without semi-conducting layer. Dimensions Cable accessories for unscreened cables L = Length Characteristics • Compact dimensions • Wide conductor and cross-section range • High mechanical strength • Quick, safe and easy assembly Application • Indoor Note • Cable lugs not included L mm Type U0/U (Um) 3.6/6 (7.2)kV - 3.8/6.6 (7.2)kV 16-50 280 70-120 280 SEEV 150-240 280 300-400 280 Appropriate cable lugs must be ordered separately. 28 www.cellpack.com Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Core insulating tubes (tracking resistant) • Spreader cap • Filling tape • Earthing accessories • Sealing tape • Assembly instructions Nominal cross section mm² Art.-No. 16 - 50 70 - 120 150 - 240 300 - 400 145458 145461 145464 171791 Terminations Medium Voltage 2013 SEEV-F Three-core outdoor termination for armoured 3-core polymeric cables without semi-conducting layer up to 7.2 kV Dimensions L = Length Ø S = Diameter of cable shed Characteristics • Compact dimensions • Wide conductor and cross-section range • High mechanical strength • Quick, safe and easy assembly Type Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Core insulating tubes (tracking resistant) • Filling tape • Silicone sheds • Earthing accessories • Sealing tape • Tracking resistant spreader cap • Assembly instructions Application • Outdoor Note • Cable lugs not included L mm U0/U (Um) 3.6/6 (7.2)kV - 3.8/6.6 (7.2)kV 16-50 400 400 SEEV-F 70-120 150-240 400 Appropriate cable lugs must be ordered separately. Nominal cross section mm² ØS mm Art.-No. 16 - 50 70 - 120 150 - 240 80 85 85 148152 182390 148153 www.cellpack.com 29 Cable accessories for unscreened cables Terminations Type SEEV -F for outdoor applications are suitable to cover armoured three-core polymeric cables (PVC, PE, XLPE, EPR) without semi-conducting layer. 30 www.cellpack.com Medium Voltage 2013 Medium Voltage 2013 Cable accessories for screened cables Page Straight-through joints for single-core cables 32 Termination for single-core cables 37 Straight-through joints for 3-core cables 59 Termination for 3-core cables 63 Scaling the heights safely www.cellpack.com 31 Straight-through joints for single-core cables Medium Voltage 2013 CHMSV Single-core straight-through joint with screw connector Cable accessories for screened cables for all polymeric single-core cables Type CHMSV straight-through joints are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR). They allow the connection of cables with different cross sections, conductive materials, semi-conducting layers (graphite-coated, removable or strippable) and screening (copper wire or tape). With screw connector. Dimensions Characteristics • Reliable stress control due to flexible silicone stress control elements • For both copper and aluminium conductors • For all cables with copper wire or tape screen • Wide conductor and cross-section range • Quick, safe and easy assembly • Ready for immediate operation • Suitable for a wide range of applications due to innovative integrated screw connector Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Thick wall heat-shrinkable insulation tubing • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Silicone stress-control elements • Copper braid tube • Pressure springs • Innovative screw connector with conductive sheath • Stress control filling tape (blue) • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) L mm Type Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Incl. Screw connectors • Joints with a range of Um = 12 kV must be used for cables of Um = 7.2 kV. (Check minimum diameter over conductor insulation). min. Ø over conductor insulation after removal of outer semi-conducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 25-95 600 70-150 600 CHMSV 12kV 95-240 600 240-400 650 U0/U (Um) 8.7/15 (17.5)kV 25-95 600 70-150 600 CHMSV 17kV 95-240 600 240-400 700 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-95 600 50-150 600 CHMSV 24kV 95-240 600 240-400 700 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 50-150 600 95-240 600 CHMSV 36kV 240-400 700 12.6 14.7 17.3 23.1 Nominal cross section mm² 12kV www.cellpack.com 17.5kV 24kV Art.-No. 36kV 258130 258131 258132 258133 25 - 95 70 - 150 95 - 240 240 - 400 14.7 18.0 19.9 24.0 14.7 17.3 19.9 27.3 20.9 24.2 32.0 Heat-shrinkable straight-through joints, larger cross section on request 32 L = Length 258135 258136 258137 258138 25 - 95 70 - 150 95 - 240 240 - 400 258140 258141 258142 258143 16 - 95 50 - 150 95 - 240 240 - 400 50 - 150 95 - 240 240 - 400 258144 258145 258146 Straight-through joints for single-core cables Medium Voltage 2013 CHM Single-core straight-through joint for all polymeric single-core cables Type CHM straight-through joints are suitable for all single-core plastic-insulated cables (PVC, PE, XLPE, EPR). They allow the connection of cables with different cross sections, conductive materials, semi-conducting layers (graphite-coated, removable or strippable) and screening (copper wire or tape). Suitable for compression connectors. Dimensions Characteristics • Reliable stress control due to flexible silicone stress control elements • For all cables with copper wire or tape screen • Wide conductor and cross-section range • Quick, safe and easy assembly • Ready for immediate operation Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Thick wall heat-shrinkable insulation tubing • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Silicone stress-control elements • Copper braid tube • Pressure springs • Stress control filling tape (blue) • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) www.cellpack.com 33 Cable accessories for screened cables Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included • Joints with a range of Um = 12 kV must be used for cables of Um = 7.2 kV. (Check minimum diameter over conductor insulation). L = Length Straight-through joints for single-core cables min. Ø over conductor max. insulation max. Ø of L connector after removal connector mm length of outer semimm mm conducting layer mm Cable accessories for screened cables Type U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 10-25 650 9.9 35-95 650 12.6 95-240 650 17.3 CHM 12KV 150-300 700 19.9 300-400 700 23.1 500-800 850 27.3 800-1000 850 36.8 U0/U (Um) 8.7/15 (17.5)kV 35-95 650 12.6 70-240 650 17.3 CHM 17KV 240-400 700 23.1 400-630 850 27.3 630-1000 850 36.8 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 10-35 650 12.6 50-150 650 17.3 70-240 700 19.9 CHM 24KV 150-300 700 23.1 400-630 850 27.3 630-1000 850 36.8 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 650 19.9 50-150 700 23.1 700 27.3 CHM 36KV 150-300 300-500 700 27.3 500-800 850 36.8 16 25 32 40 40 60 60 90 135 145 200 200 360 360 25 32 40 60 60 135 145 200 360 360 20 25 32 40 60 60 100 135 145 200 360 360 20 25 38 45 60 110 135 200 200 360 Armour continuity kit must be ordered separately. Appropriate compression connector must be ordered separately. 34 www.cellpack.com Medium Voltage 2013 Nominal cross section mm² Art.-No. 12kV 17.5kV 24kV 36kV 194072 194073 194074 194075 194076 194077 194078 10 - 25 35 - 95 95 - 240 150 - 300 300 - 400 500 - 800 800 - 1000 194079 194080 194082 194083 194085 35 - 95 70 - 240 240 - 400 400 - 630 630 - 1000 193339 193370 194086 194087 194088 194089 10 - 35 50 - 150 70 - 240 150 - 300 400 - 630 630 - 1000 35 - 70 50 - 150 150 - 300 300 - 500 500 - 800 194090 194091 194092 194093 194094 Straight-through joints for single-core cables Medium Voltage 2013 CAM-S Single-core straight-through joint for all polymeric single-core cables Characteristics • Reliable stress control due to flexible silicone stress control elements • Wide conductor and cross-section range • Ready for immediate operation • Silicone slip-on components for quick, safe and easy assembly Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included • Joints with a range of Um = 12 kV must be used for cables of Um = 7.2 kV. (Check minimum diameter over conductor insulation). min. Ø over conductor insulation after Type removal of outer semiconducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 25-95 700 12.6 CAM-S 12kV 50-240 700 14.7 150-400 700 19.9 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-120 700 14.7 CAM-S 24kV 70-240 700 19.9 L mm max. connector length mm 160 160 160 Dimensions L = Length Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Silicone stress-control elements • Silicone joint body with integrated semi-conducting layer (individually tested) • Copper braid tube • Pressure springs • Semi-conducting tape • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) Nominal cross section mm² 12kV 201385 201386 201388 25 - 95 50 - 240 150 - 400 160 160 Art.-No. 24kV 16 - 120 70 - 240 201393 201395 Appropriate compression connector must be ordered separately. www.cellpack.com 35 Cable accessories for screened cables Type CAM-S straight-through joints are suitable for all single-core plastic-insulated cables (PVC, PE, XLPE, EPR). They allow the connection of cables with different cross sections, conductive materials, semi-conducting layers (graphite-coated, removable or strippable) and screening (wire or tape screen). Suitable for compression connectors. Straight-through joints for single-core cables Medium Voltage 2013 CKM Single-core straight-through joint with screw connector for all polymeric single-core cables Type CKM straight-through joints are suitable for all single-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated, removable or strippable) and screening (wire or tape screen) up to a maximum network voltage of 24kV. With screw connectors integrated. Dimensions Cable accessories for screened cables L = Length H = Heigth B = Width Characteristics • Compact design • Quick, safe and easy assembly • With integrated screw connectors • Ready for immediate operation • Resistant to alkaline earth elements • Moisture-resistant • Corrosion-resistant • Superior mechanical properties L mm Type Application • Indoor • Underground • Installation ducts B mm H mm U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 50-150 470 71 85 CKM 24kV 95-240 470 71 85 36 www.cellpack.com min. Ø over conductor insulation after removal of outer semi-conducting layer mm 15.1 - 28.5 19.9 - 32.6 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Double plug • Joint body with integrated outer housing, inner semi-conducting layer, silicon stress-control element and shear-bolt connector • Pressure springs • Padding tape • Housing cover with integrated seal • Protective sleeve with slide-on applicator • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) Nominal cross section mm² 12kV 17.5kV 24kV 70 - 150 120 - 240 70 - 150 120 - 240 50 - 150 95 - 240 Art.-No. 252101 251713 Termination for single-core cables Medium Voltage 2013 CHE-I Single-core indoor termination for all polymeric single-core cables Dimensions Type CHE-I terminations are suitable for all single-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (copper wire or tape). L = Length Ø S = Diameter of cable sheds Application • Indoor Note • Cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). Each unit contains materials for one set of three terminations. Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • 1 Set for 3 phases • Tracking-resistant heat-shrink tubing • Silicone stress-control elements • Silicone sheds • Sealing tape • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) www.cellpack.com Cable accessories for screened cables Characteristics • Flexible silicone stress control elements ensure reliable stress control under all operating conditions • Combination of slip-on and heat-shrink components • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation 37 Cable accessories for screened cables Termination for single-core cables min. Ø Number over conductor of L insulation after ØS Type sheds mm removal of outer mm per semi-conducting phase layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 10-25 300 9.9 25-95 300 12.6 95-240 300 17.3 CHE-I 12kV 150-400 300 19.9 240-500 300 23.1 400-800 300 27.3 800-1000 300 36.8 U0/U (Um) 8.7/15 (17.5)kV 10-16 300 9.9 1 80 16-50 300 12.6 1 80 70-240 300 17.3 1 85 CHE-I 17kV 120-300 300 19.9 1 85 185-400 300 23.1 1 85 300-630 300 27.3 1 115 630-1000 300 36.8 1 123 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 10-35 300 12.6 1 85 25-150 300 17.3 1 85 70-240 300 19.9 1 85 CHE-I 24kV 120-300 300 23.1 1 85 240-500 300 27.3 1 115 630-1000 300 36.8 1 123 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 500 19.9 2 85 50-150 500 23.1 2 85 CHE-I 36kV 150-400 500 27.3 2 115 500-800 500 36.8 2 123 Medium Voltage 2013 Nominal cross section mm² 12kV www.cellpack.com 24kV 36kV 193414 193416 194017 194018 194019 194030 194031 10 - 25 25 - 95 95 - 240 150 - 400 240 - 500 400 - 800 800 - 1000 Appropriate cable lugs must be ordered separately. Type EGA earthing kit for cables with tape screen must be ordered separately. 38 17.5kV Art.-No. 194032 194033 194034 194035 194036 194037 194038 10 - 16 16 - 50 70 - 240 120 - 300 185 - 400 300 - 630 630 - 1000 194039 194040 194041 194042 194043 194044 10 - 35 25 - 150 70 - 240 120 - 300 240 - 500 630 - 1000 35 - 70 50 - 150 150 - 400 500 - 800 194045 194046 194047 194048 Termination for single-core cables Medium Voltage 2013 CHE-F Single-core outdoor termination for all polymeric single-core cables Dimensions Type CHE-F terminations are suitable for all single-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (copper wire or tape). L = Length Ø S = Diameter of cable sheds Application • Outdoor Note • Cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). Each unit contains materials for one set of three terminations. Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • 1 Set for 3 phases • Tracking-resistant heat-shrink tubing • Silicone stress-control elements • Silicone sheds • Sealing tape • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) www.cellpack.com Cable accessories for screened cables Characteristics • Flexible silicone stress control elements ensure reliable stress control under all operating conditions • Combination of slip-on and heat-shrink components • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation 39 Cable accessories for screened cables Termination for single-core cables min. Ø over conductor Number L insulation after of sheds Ø S Type mm removal of outer per mm semi-conducting phase layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 10-25 300 9.9 1 80 25-95 300 12.6 1 80 95-240 300 17.3 1 85 CHE-F 12kV 150-400 300 19.9 1 85 240-500 300 23.1 1 85 400-800 300 27.3 1 115 800-1000 300 36.8 1 123 U0/U (Um) 8.7/15 (17.5)kV 10-16 500 9.9 2 80 16-50 500 12.6 2 80 70-240 500 17.3 2 85 CHE-F 17kV 120-300 500 19.9 2 85 185-400 500 23.1 2 85 300-630 500 27.3 2 115 630-1000 500 36.8 2 123 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 10-35 500 12.6 3 85 25-150 500 17.3 3 85 70-240 500 19.9 3 85 CHE-F 24kV 120-300 500 23.1 3 85 240-500 500 27.3 3 115 630-1000 500 36.8 3 123 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 700 19.9 4 85 50-150 700 23.1 4 85 CHE-F 36kV 150-400 700 27.3 4 115 500-800 700 36.8 4 123 Medium Voltage 2013 Nominal cross section mm² 12kV www.cellpack.com 24KV 36kV 194049 194050 194051 194052 194053 194054 194055 10 - 25 25 - 95 95 - 240 150 - 400 240 - 500 400 - 8000 800 - 1000 Appropriate cable lugs must be ordered separately. Type EGA earthing kit for cables with tape screen must be ordered separately. 40 17.5kV Art.-No. 194056 194057 194058 194059 194061 194062 194063 10 - 16 16 - 50 70 - 240 120 - 300 185 - 400 300 - 630 630 - 1000 193372 193374 194064 194065 194066 194067 10 - 35 25 - 150 70 - 240 120 - 300 240 - 500 630 - 1000 35 - 70 50 - 150 150 - 400 500 - 800 194068 194069 194070 194071 Termination for single-core cables Medium Voltage 2013 CAESK-I Single-core indoor termination with screw cable lugs for all polymeric single-core cables Dimensions Type CAESK-I terminations are suitable for all single-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (wire or tape screen). With screw cable lug. Characteristics • Wide cross-section range • Silicone slip-on components for quick, safe and easy assembly • Ready for immediate operation Application • Indoor Note • Incl. Screw cable lugs • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • 3 one-piece slip-on silicone terminations with integrated stress control element • Silicone tube • Sealing tape • Screw cable lug for main conductor • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) min. Ø Nominal cross section Number over conductor mm² of L insulation after ØS Type sheds mm removal of outer mm per semi-conducting 12kV 17.5kV 24kV 36kV phase layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 95-150 310 17.3 1 87 95 - 150 150-240 330 19.9 1 90 150 - 240 CAESK-I 12kV 300-400 340 26.6 1 93 300 - 400 500-630 360 32.3 1 97 500 - 630 U0/U (Um) 8.7/15 (17.5)kV 50-95 310 17.3 1 87 50 - 95 95-150 310 19.9 1 90 95 - 150 CAESK-I 17kV 150-240 330 23.1 1 93 150 - 240 240-400 340 27.3 1 97 240 - 400 400-500 360 32.3 1 97 400 - 500 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 35-95 310 17.3 1 87 35 - 95 70-150 310 19.9 1 90 70 - 150 CAESK-I 24kV 120-240 330 23.1 1 90 120 - 240 240-400 340 27.3 1 97 240 - 400 400-500 360 32.3 1 97 400 - 500 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 16-95 360 20.9 4 93 16 - 95 70-150 360 24.2 4 93 70 - 150 CAESK-I 36kV 120-240 380 28.6 4 97 120 - 240 240-300 390 32.3 4 97 240 - 300 Art.-No. 289945 289947 289948 289949 289950 289951 289952 289953 289954 289955 289956 289957 289958 289959 289960 289961 289962 289963 Type EGA earthing kit for cables with tape screen must be ordered separately. www.cellpack.com 41 Cable accessories for screened cables L = Length Ø S = Diameter of cable sheds Termination for single-core cables Medium Voltage 2013 CAE-I Single-core indoor termination for all polymeric single-core cables Type CAE-I terminations are suitable for all single-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (wire or tape screen). Suitable for compression cable lugs. Dimensions Cable accessories for screened cables L = Length Ø S = Diameter of cable sheds Characteristics • Wide cross-section range • Silicone slip-on components for quick, safe and easy assembly • Ready for immediate operation Type U0/U (Um) CAE-I 12kV U0/U (Um) CAE-I 17kV U0/U (Um) CAE-I 24kV U0/U (Um) CAE-I 36kV Application • Indoor Note • Compression cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). min. Ø over conductor L insulation after mm removal of outer semi-conducting layer mm 6/10 (12)kV - 6.35/11 (12)kV 95-240 270 17.3 150-400 270 19.9 240-500 270 23.1 300-800 270 27.3 8.7/15 (17.5)kV 50-185 270 17.3 95-240 270 19.9 150-400 270 23.1 240-630 270 27.3 12/20 (24)kV - 12.7/22 (24)kV 35-120 270 17.3 70-240 270 19.9 120-400 270 23.1 240-630 270 27.3 18/30 (36)kV - 19/33 (36)kV 16-95 325 19.9 50-240 325 23.1 120-400 325 27.3 Number of ØS sheds mm per phase www.cellpack.com Nominal cross section mm² 12kV 1 1 1 1 87 95 - 240 90 150 - 400 93 240 - 500 97 300 - 800 1 1 1 1 87 90 93 97 1 1 1 1 87 90 93 97 4 4 4 90 93 97 Appropriate cable lugs must be ordered separately. Accessories for cables with tape screen must be ordered separately. 42 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • 3 one-piece slip-on silicone terminations with integrated stress control element • Sealing tape • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) 17.5kV 24kV Art.-No. 36kV 199151 199152 199154 199155 199157 199158 199159 199160 50 - 185 95 - 240 150 - 400 240 - 630 35 - 120 70 - 240 120 - 400 240 - 630 199162 199163 199164 199165 16 - 95 199166 50 - 240 199167 120 - 400 199168 Termination for single-core cables Medium Voltage 2013 CAESK-F Single-core outdoor termination with screw cable lugs for all polymeric single-core cables Type CAESK-F terminations are suitable for all single-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (wire or tape screen). With screw cable lug. Dimensions Characteristics • Wide cross-section range • Silicone slip-on components for quick, safe and easy assembly • Ready for immediate operation Application • Outdoor Note • Incl. Screw cable lugs • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • 3 one-piece slip-on silicone terminations with integrated stress control element • Silicone tube • Sealing tape • Screw cable lug for main conductor • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) min. Ø Nominal cross section over conductor Number mm² insulation after of L ØS Type removal of sheds mm mm outer semiper 12kV 17.5kV 24kV 36kV conducting phase layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 95-150 360 17.3 4 87 95 - 150 150-240 390 19.9 4 90 150 - 240 CAESK-F 12kV 300-400 390 26.6 4 93 300 - 400 500-630 410 32.3 4 97 500 - 630 U0/U (Um) 8.7/15 (17.5)kV 50-95 360 17.3 4 87 50 - 95 95-150 360 19.9 4 90 95 - 150 CAESK-F 17kV 150-240 390 23.1 4 97 150 - 240 240-400 410 27.3 4 97 240 - 400 400-500 410 32.3 4 97 400 - 500 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 35-95 360 17.3 4 87 35 - 95 70-150 360 19.9 4 90 70 - 150 CAESK-F 24kV 120-240 390 23.1 4 93 120 - 240 240-400 410 27.3 4 97 240 - 400 400-500 410 32.3 4 97 400 - 500 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 70-150 470 24.2 5 93 70 - 150 28.6 5 97 120 - 240 CAESK-F 36kV 120-240 500 240-300 500 32.3 5 97 240 - 300 Art.-No. 289894 289897 289898 289899 289900 289901 289902 289903 289904 289905 289906 289907 289908 289909 289910 289911 289912 Type EGA earthing kit for cables with tape screen must be ordered separately. www.cellpack.com 43 Cable accessories for screened cables L = Length Ø S = Diameter of cable sheds Termination for single-core cables Medium Voltage 2013 CAE-F Single-core outdoor termination for all polymeric single-core cables Dimensions Type CAE-F terminations are suitable for all single-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (wire or tape screen). Suitable for compression cable lugs. Cable accessories for screened cables L = Length Ø S = Diameter of cable sheds Characteristics • Wide cross-section range • Silicone slip-on components for quick, safe and easy assembly • Ready for immediate operation Application • Outdoor Note • Compression cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). min. Ø over conductor Number insulation after of L ØS removal of outer sheds mm mm semi-conducting per layer mm phase Type U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 95-240 325 17.3 150-400 325 19.9 CAE-F 12kV 240-500 325 23.1 300-800 325 27.3 U0/U (Um) 8.7/15 (17.5)kV 50-185 325 17.3 95-240 325 19.9 CAE-F 17kV 150-400 325 23.1 240-630 325 27.3 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 35-120 325 17.3 70-240 325 19.9 CAE-F 24kV 120-400 325 23.1 240-630 325 27.3 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 50-240 440 23.1 CAE-F 36kV 120-400 440 27.3 www.cellpack.com Nominal cross section mm² 12kV 4 4 4 4 87 95 - 240 90 150 - 400 93 240 - 500 97 300 - 800 4 4 4 4 87 90 93 97 4 4 4 4 87 90 93 97 5 5 93 97 Appropriate compression cable lugs must be ordered separately. Type EGA earthing kit for cables with tape screen must be ordered separately. 44 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • 3 one-piece slip-on silicone terminations with integrated stress control element • Sealing tape • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) 17.5kV 24kV Art.-No. 36kV 199184 199185 199186 199187 199189 199190 199191 199192 50 - 185 95 - 240 150 - 400 240 - 630 35 - 120 70 - 240 120 - 400 240 - 630 199194 199195 199196 199197 50 - 240 199198 120 - 400 199199 Termination for single-core cables Medium Voltage 2013 CWS 250A/M Elbow separable cable connector with capacitive measuring point for all polymeric single-core cables Cellplux elbow separable cable connectors are suitable for the connection of all plastic-insulated single-core cables (PVC,PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated, removable or strippable) and screening (wire or tape screen) to switching equipment and transformers having plug-in connections for Type A outer cone system terminals (in accordance with EN 50180, EN 50181 and DIN 47636) up to a maximum network voltage of 24 kV. Dimensions L = Length H = Heigth B = Width Type L mm Application • Indoor B mm U0/U (Um) 6/10 (12)kV - 12.7/22 (24)kV 16-95 M/EGA 176 80 CWS 250A 24kV 70-150 M/EGA 176 80 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Set of 3 separable cable connectors • Silicone stress-control elements • Earthing kit • Assembly accessories • Screw cable lug for main conductor • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) min. Ø over conductor insulation after H removal of outer mm semi-conducting layer mm 178 178 14.7 19.9 Nominal cross section mm² 12kV 17.5kV Cable accessories for screened cables Characteristics • with capacitive measuring point • Individually tested • Outer semi-conducting layer made of semi-conductive EPDM provides protection from exposed electrical parts. • Cable sheath insulation fault test may be performed under voltage • For both copper and aluminium conductors • Quick, safe and easy assembly • Suitable for a wide range of applications due to integrated screw cable lug Art.-No. 24kV 50 - 95 25 - 95 16 - 95 295167 120 - 150 95 - 150 70 - 150 293792 www.cellpack.com 45 Termination for single-core cables Medium Voltage 2013 CGS 250A/M Straight separable cable connector with capacitive measuring point for all polymeric single-core cables Cellplux straight separable cable connectors are suitable for the connection of all plastic-insulated single-core cables (PVC,PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (wire or tape screen) to switching equipment and transformers having plug-in connections for Type A outer cone system terminals (in accordance with EN 50180, EN 50181 and DIN 47636) up to a maximum network voltage of 24 kV. Dimensions Cable accessories for screened cables L = Length B = Width Characteristics • with capacitive measuring point • Individually tested • Outer semi-conducting layer made of semi-conductive EPDM provides protection from exposed electrical parts. • Cable sheath insulation fault test may be performed under voltage • For both copper and aluminium conductors • Quick, safe and easy assembly • Suitable for a wide range of applications due to integrated screw cable lug L mm Type Application • Indoor B mm U0/U (Um) 6/10 (12)kV - 12.7/22 (24)kV 25-95 M/EGA 248 110 CGS 250A 24kV 70-150 M/EGA 248 110 46 www.cellpack.com Storage conditions/Shelf life • 12 months • Unlimited shelf life Scope of delivery • Set of 3 separable cable connectors • Silicone stress-control elements • Earthing kit • Assembly accessories • Screw cable lug for main conductor • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) min. Ø over conductor insulation after removal of outer semi-conducting layer mm 14.7 19.9 Nominal cross section mm² 12kV 17.5kV 24kV 50 - 95 120 - 150 25 - 95 95 - 150 25 - 95 70 - 150 Art.-No. 295283 293797 Termination for single-core cables Medium Voltage 2013 CVS 250A Connector element up to 24kV for plug-in cable connector type CWS, CGS The CVS plug-in connector element is suitable for the connection of two elbow and/or straight separable CWS 250A or CGS 250A connectors. Its dimensions correspond to Type A outer cone systems according to EN 50180, EN 50181 and DIN 47636. Dimensions L = Length Ø = Diameter Application • Indoor Type U0/U (Um) 6/10 (12)kV - 12.7/22 (24)kV CVS 24kV Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Set of 3 connectors • Assembly accessories • Assembly instructions Cable accessories for screened cables Characteristics • Individually tested • Easy assembly • Safe and easy to handle L mm ØD mm Art.-No. 136 100 225844 www.cellpack.com 47 Termination for single-core cables Medium Voltage 2013 CWS 400A Elbow separable cable connector for all polymeric single-core cables Cellplux elbow separable cable connectors are suitable for the connection of all plastic-insulated single-core cables (PVC,PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (wire or tape screen) to switching equipment and transformers having plug-in connections for Type B outer cone system terminals (in accordance with EN 50180, EN 50181 and DIN 47636) up to a maximum network voltage of 36 kV. Dimensions Cable accessories for screened cables L = Length H = Heigth B = Width Characteristics • Outer semi-conducting layer made of semi-conductive EPDM provides protection from exposed electrical parts. • Cable sheath insulation fault test may be performed under voltage • For both copper and aluminium conductors • Quick, safe and easy assembly • Suitable for a wide range of applications due to integrated screw cable lug • With capacitive measurement • Individually tested Application • Indoor Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Set of 3 separable cable connectors • Silicone stress-control elements • Earthing kit • Assembly accessories • Screw cable lug for main conductor • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) min. Ø over Nominal cross section conductor mm² L B H insulation after Type mm mm mm removal of outer semi-conducting 12kV 17.5kV 24kV 36kV layer mm U0/U (Um) 6/10 (12)kV - 12.7/22 (24)kV 25-70 EGA 215 107 250 14.7 50 - 95 25 - 95 25 - 70 CWS 400A 24kV 95-240 EGA 215 107 250 22.0 150 - 240 120 - 240 95 - 240 U0/U (Um) 12/20 (24)kV - 19/33 (36)kV 50-95 EGA 215 107 250 22.0 95 - 95 50 - 95 CWS 400A 36kV 150-240 EGA 215 107 250 30.8 240 - 240 150 - 240 Type EGA earthing kit for cables with tape screen must be ordered separately. 48 www.cellpack.com Art.-No. 250720 246176 250726 247102 Termination for single-core cables Medium Voltage 2013 CTS 630A T-separable cable connector for all polymeric single-core cables CTS shear bolt Cellplux separable cable connectors are suitable for connecting all plastic-insulated single-core cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (wire or tape) to substations and transformers for a maximum system voltage of 36 kV, with plug-type connections for Type C Taper Male Plug System complying with EN 50180 and EN 50181. Dimensions L = Length H = Heigth B = Width Type L mm Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Set of 3 separable cable connectors • Silicone stress-control elements • Earthing kit • Assembly accessories • Screw cable lug for main conductor • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) Application • Indoor B mm U0/U (Um) 6/10 (12)kV - 12.7/22 (24)kV 25-70 EGA 194 85 194 85 CTS 630A 24kV 95-240 EGA 240-300 EGA 194 85 U0/U (Um) 12/20 (24)kV - 19/33 (36)kV 50-95 EGA 194 85 95-150 EGA 194 85 CTS 630A 36kV 150-240 EGA 194 85 240-400 EGA 194 85 H mm min. Ø over conductor insulation after removal of outer semi-conducting layer mm 250 250 250 14.7 22 23.7 250 250 250 265 22 22 30.8 31.5 Cable accessories for screened cables Characteristics • Individually tested • Outer semi-conducting layer made of semi-conductive EPDM provides protection from exposed electrical parts. • Cable sheath insulation fault test may be performed under voltage • For both copper and aluminium conductors • Quick, safe and easy assembly • Suitable for a wide range of applications due to integrated screw cable lug • With capacitive measurement Nominal cross section mm² Art.-No. 12kV 17.5kV 24kV 36kV 50 - 95 25 - 95 25 - 70 150 - 240 120 - 240 95 - 240 240 - 400 240 - 300 240 - 300 95 - 95 50 - 95 95 - 240 95 - 150 240 - 240 150 - 240 300 - 400 240 - 400 250711 220775 302732 250715 256010 224826 256328 Type EGA earthing kit for cables with tape screen must be ordered separately. More T-socket connexions on request www.cellpack.com 49 Termination for single-core cables Medium Voltage 2013 CTKS 630A T-separable coupling connector for all polymeric single-core cables The CTKS coupling connectors are suitable for connecting all plastic-insulated single-core cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (wire or tape), to the back of Cellplux separable cable connectors, model CTS 630 A. Dimensions Cable accessories for screened cables L = Length B = Width Characteristics • Outer semi-conducting layer made of semi-conductive EPDM provides protection from exposed electrical parts. • Cable sheath insulation fault test may be performed under voltage • For both copper and aluminium conductors • Quick, safe and easy assembly • Suitable for a wide range of applications due to integrated screw cable lug • With capacitive measurement • Individually tested Application • Indoor Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Set of 3 coupling elements • Silicone stress-control elements • Earthing kit • Assembly accessories • Screw cable lug for main conductor • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) min. Ø Nominal cross section over conductor mm² insulation after L B H Type removal of outer mm mm mm semi-conducting 12kV 17.5kV 24kV 36kV layer mm mm U0/U (Um) 6/10 (12)kV - 12.7/22 (24)kV 25-70 EGA 290 74 250 14.7 50 - 95 25 - 95 25 - 70 CTKS 630A 24kV 95-240 EGA 290 74 250 22 150 - 240 120 - 240 95 - 240 U0/U (Um) 12/20 (24)kV - 19/33 (36)kV 50-95 310 85 250 22 95 - 95 50 - 95 CTKS 630A 36kV 150-240 310 85 250 30.8 240 - 240 150 - 240 Type EGA earthing kit for cables with tape screen must be ordered separately. 50 www.cellpack.com Art.-No. 256838 256839 257581 257582 Termination for single-core cables Medium Voltage 2013 CTKSA Coupling Surge Arrester Class 1 The CTKSA Surge Arrester is designed for the protection of encapsulated medium voltage installations with a maximum operating voltage of 24 kV. Its compact design allows direct connection to double-row CTS 630A screw plugs and complies with International Standard IEC 60099-4. Application • Indoor Note • Each unit contains materials for one set of three plugs Scope of delivery • Set of three surge arresters, electrically tested • Assembly accessories • Secondary components • Assembly instructions Cable accessories for screened cables Characteristics • Individually tested • Protection from exposed electrical parts by EPDM outer protection • Quick, safe and easy assembly • Protection from exposed electrical parts • With capacitive measurement Maximum ambient temperature: 60°C System overvoltage (per unit of MCOV) (Per unit of Ur) Time (seconds) Art.-No. Nominal leakage current I [kA] Rated voltage Ur [kV] Maximum Operating Voltage Uc [kV] Partial discharge at Uc [pC] Residual voltage [kV] at: Steep current impulse 1/20 μs Switching impulse current 125A Switching impulse current 500A Lightning impulse current 8/20 μs CTKSA 12kV CTKSA 17kV CTKSA 19.5kV CTKSA 24kV 262054 10 15 12.7 <5 262055 10 21 17 <5 262816 10 24 19.5 <5 262056 10 30 24 <5 41.8 28.2 30.1 37.6 58.5 39.4 42.2 52.6 66.9 45.1 48.2 60.2 83.5 56.5 60.3 75.5 www.cellpack.com 51 Termination for single-core cables Medium Voltage 2013 CTKSA Coupling Surge Arrester Class 2 Characteristics • Individually tested • Protection from exposed electrical parts by EPDM outer protection • Quick, safe and easy assembly • Protection from exposed electrical parts Application • Indoor Note • Each unit contains materials for one set of three plugs Scope of delivery • Set of three surge arresters, electrically tested • Assembly accessories • Secondary components • Assembly instructions Maximum ambient temperature: 60°C (Per unit of Ur) System overvoltage (per unit of Uc) Cable accessories for screened cables The CTKSA Surge Arrester is designed for the protection of encapsulated medium voltage installations with a maximum operating voltage of 34 kV. Its compact design allows direct connection to double-row CTS 630A screw plugs and complies with International Standard IEC 60099-4. Time (seconds) CTKSA 34kV Art.-No. Nominal leakage current I [kA] Rated voltage Ur [kV] Maximum Operating Voltage Uc [kV] Partial discharge at Uc [pC] Residual voltage [kV] at: Steep current impulse 1/20 μs Switching impulse current 250A Switching impulse current 500A Lightning impulse current 8/20 μs 52 www.cellpack.com 301492 10 42 34 <5 120.4 84 89.6 108.4 Termination for single-core cables Medium Voltage 2013 CIK Voltage-proof Insulating Cap The CIK Voltage-proof Insulation Cap provides electrical insulation for Types A 250A and C 630A bushings in encapsulated substations and transformers up to 36kV, in compliance with EN 50180 and EN 50181. Note • Each unit contains materials for one set of three isulating caps Scope of delivery • 3 x Voltage-proof Insulating caps • Assembly accessories • Assembly instructions Cable accessories for screened cables Characteristics • Submersible • Easy assembly • Protection from exposed electrical parts Type Art.-No. U0/U (Um) 6/10 (12)kV - 12.7/22 (24)kV CIK 250A 24kV U0/U (Um) 6/10 (12)kV - 19/33 (36)kV CIK 630A 36kV 265023 265024 www.cellpack.com 53 Termination for single-core cables Medium Voltage 2013 ZS-CTS Accessory Kit for Type CTS 630A Cellplux separable cable Connectors The ZS-CTS Accessory Kit is designed for the reinstallation of separable cable connectors in substations and transformers with bushings for Type C outer cone systems complying with EN 50180, EN 50181. The inclusion of the tried and tested contact pin with shear bolt in this kit eliminates the possibility of faulty assembly of cable systems. Cable accessories for screened cables Application • Reinstallation of Type CTS separable Cable Connector Note • Each unit contains materials for one set of three shear bolts Scope of delivery • Set of 3 contact pins with shear bolt • Assembly accessories • Assembly instructions Type Art.-No. ZS-CTS 257622 54 www.cellpack.com Medium Voltage 2013 Termination for single-core cables Mounting Ring The Mounting Ring is designed to secure CWS 250A and CGS 250A Cellplux separable Cable Connectors to a special bushing for Type A outer cone systems. The Mounting Ring is simply placed in the prefabricated groove in the cable connector. The two components may then be mounted on the bushing together. Scope of delivery • 1 x Mounting Ring Cable accessories for screened cables Characteristics • Easy assembly • Secure connection to special Type A bushing Type Art.-No. Mounting Ring 264366 www.cellpack.com 55 Termination for single-core cables Medium Voltage 2013 CKS 630A Coupling connector up to 24kV for separable cable connector type CTS The CKS shear bolt coupling connector is intended for the connection of two CTS separable cable connectors up to 24 kV at up to a rated current of 630 A. The dimensions of the longer outer cone correspond to Type C outer cone systems in accordance with EN 50180, EN 50181. Dimensions L = Length D = External diameter Cable accessories for screened cables Characteristics • Individually tested • Easy assembly • Safe and easy to handle Application • Indoor L mm Type U0/U (Um) 6/10 (12)kV - 12.7/22 (24)kV CKS 630A 24kV 196.5 56 www.cellpack.com Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Set of 3 coupling elements • Assembly accessories • Assembly instructions L1 mm L2 mm D mm D1 mm D2 mm Art.-No. 61.5 91 70 56 46 224853 Termination for single-core cables Medium Voltage 2013 CPES Test and earthing Kit The Test and Earthing Kit is designed for the establishment of galvanic connections between cable conductors and is compatible with all Type CTS and CTKS Cellplux T-plugs. Scope of delivery • 1 x Test adapter • 3 x Earthing adapter • 1 x Case • Assembly instructions Cable accessories for screened cables Application • Cable testing • Cable fault location • Phase compensation • Earthing for work Type Art.-No. U0/U (Um) 6/10 (12)kV - 19/33 (36)kV CPES Test and Earthing Kit 259101 www.cellpack.com 57 Termination for single-core cables Medium Voltage 2013 CPS Test-Kit The Test- Kit is designed for the establishment of galvanic connections between cable conductors and is compatible with all Type CTS and CTKS Cellplux T-plugs. Scope of delivery • 3 x Test adapter • 1 x Case • Assembly instructions Cable accessories for screened cables Application • Cable testing • Cable fault location • Phase compensation Type Art.-No. U0/U (Um) 6/10 (12)kV - 19/33 (36)kV CPS Test-Kit 302227 58 www.cellpack.com Straight-through joints for 3-core cables Medium Voltage 2013 CHMSV3 Three-core straight-through joint with screw connector for all 3-core polymeric cables Type CHMSV 3 straight-through joints are suitable for connecting three-core polymeric cable (PVC, PE, XLPE, EPR). They allow the connection of cables with copper wire screen, with different cross sections, conductor materials, semi-conducting layers (graphite-coated, removable or strippable). Screw connectors included. Dimensions Characteristics • Reliable stress control due to flexible silicone stress control elements • For both copper and aluminium conductors • For all cables with copper-wire screen • Wide conductor and cross-section range • Quick, safe and easy assembly • Ready for immediate operation • Suitable for a wide range of applications due to innovative integrated screw connector Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Thick wall heat-shrinkable insulation tubing • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Silicone stress-control element • Copper braid tape • Innovative screw connector with conductive sheath • Stress control filling tape (blue) • Screw connector for copper-wire screen • Assembly instructions Type min. Ø over conductor insulation after L removal of outer mm semi-conducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 25-95 1050 12.6 70-150 1050 14.7 CHMSV 3 12kV 95-240 1100 17.3 240-400 1250 23.1 U0/U (Um) 8.7 /15 (17.5)kV 25-95 1050 14.7 70-150 1050 18 CHMSV 3 17kV 95-240 1100 19.9 240-400 1250 24 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-95 1050 14.7 50-150 1050 17.3 CHMSV 3 24kV 95-240 1100 19.9 240-400 1250 27.3 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 50-150 1050 20.9 CHMSV 3 36kV 95-240 1100 24.2 240-400 1250 32 Nominal cross section mm² Art.-No. 12kV 17.5kV 24kV 36kV 297348 297350 297260 297358 25 - 95 70 - 150 95 - 240 240 - 400 297349 297351 297310 297360 25 - 95 70 - 150 95 - 240 240 - 400 297433 297352 297104 297361 16 - 95 50 - 150 95 - 240 240 - 400 50 - 150 95 - 240 240 - 400 297353 297311 297362 www.cellpack.com 59 Cable accessories for screened cables Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Incl. screw connectors L = Length Straight-through joints for 3-core cables Medium Voltage 2013 CHMSV3-1 Straight-through joint with screw connector for connecting from three-core with single-core polymeric cable Type CHMSV 3-1 straight-through joints are suitable for connecting three-core polymeric cable with three single-core polymeric cable (PVC, PE, XLPE, EPR). They allow the connection of cables with copper wire screen, with different cross sections, conductor materials, semi-conducting layers (graphite-coated, removable or strippable). Screw connectors included. Dimensions Cable accessories for screened cables L = Length Characteristics • Reliable stress control due to flexible silicone stress control elements • For both copper and aluminium conductors • For all cables with copper-wire screen • Wide conductor and cross-section range • Quick, safe and easy assembly • Ready for immediate operation • Suitable for a wide range of applications due to innovative integrated screw connector L mm Type Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Incl. screw connectors min. Ø over conductor insulation after removal of outer semi-conducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 25-95 900 70-150 900 CHMSV 3-1 12kV 95-240 900 240-400 1000 U0/U (Um) 8.7/15 (17.5)kV 25-95 900 70-150 900 CHMSV 3-1 17kV 95-240 900 240-400 1000 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-95 900 50-150 900 CHMSV 3-1 24kV 95-240 900 240-400 1000 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 50-150 900 CHMSV 3-1 36kV 95-240 900 240-400 1000 60 www.cellpack.com 12.6 14.7 17.3 23.1 17.4 18 19.9 24 14.7 17.3 19.9 27.3 20.9 24.2 32 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Thick wall heat-shrinkable insulation tubing • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Silicone stress-control element • Copper braid tape • Innovative screw connector with conductive sheath • Stress control filling tape (blue) • Screw connector for copper-wire screen • Assembly instructions Nominal cross section mm² 12kV 17.5kV 24kV Art.-No. 36kV 297449 297462 297442 297466 25 - 95 70 - 150 95 - 240 240 - 400 297460 297463 297443 297467 25 - 95 70 - 150 95 - 240 240 - 400 16 - 95 50 - 150 95 - 240 240 - 400 297461 297464 297441 297468 50 - 150 297465 95 - 240 297444 240 - 400 297469 Straight-through joints for 3-core cables Medium Voltage 2013 CHM3 Three-core straight-through joint for all 3-core polymeric cables Type CHM3 straight-through joints are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR). They allow the connection of cables with different cross sections, conductive materials, semi-conducting layers (graphite-coated, removable or strippable) and screen (copper wire or tape). Suitable for compression connectors. Dimensions Characteristics • Reliable stress control due to flexible silicone stress control elements • Wide conductor and cross-section range • Quick, safe and easy assembly • Ready for immediate operation Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Thick wall heat-shrinkable insulation tubing • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Silicone stress-control element • Copper braid tube • Pressure springs • Stress control filling tape (blue) • Assembly instructions min. Ø Nominal cross section over conductor max. max. mm² insulation Ø of connector L Type after removal mm connector length of outer semimm mm 12kV 17.5kV 24kV 36kV conducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 10-25 1200 9.9 16 90 10 - 25 35-95 1200 12.6 25 135 35 - 95 CHM3 12kV 95-240 1200 17.3 32 145 95 - 240 150-300 1200 19.9 40 200 150 - 300 U0/U (Um) 8.7/15 (17.5)kV 35-95 1200 12.6 25 135 35 - 95 70-240 1200 17.3 32 145 70 - 240 CHM3 17kV 120-300 1200 19.9 34 150 120 - 300 240-400 1200 23.1 40 200 240 - 400 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 10-35 1200 12.6 20 100 10 - 35 50-150 1200 17.3 25 135 50 - 150 CHM3 24kV 70-240 1200 19.9 32 145 70 - 240 150-300 1200 23.1 40 200 150 - 300 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 1200 19.9 20 110 35 - 70 1200 23.1 25 135 50 - 150 CHM3 36kV 50-150 150-300 1200 27.3 38 200 150 - 300 Art.-No. 194293 194294 194295 194296 194297 194298 194299 194300 194301 194302 194303 194304 194305 194306 194307 Appropriate compression connectors must be ordered separately. Armour continuity kit for armoured cable available to order. www.cellpack.com 61 Cable accessories for screened cables Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included • Joints with a range of Um = 12 kV must be used for cables of Um = 7.2 kV. (Check minimum diameter over conductor insulation). L = Length Straight-through joints for 3-core cables Medium Voltage 2013 CAM3-S Three-core straight-through joint with heat-shrink outer protection for all 3-core polymeric cables Cable accessories for screened cables Dimensions Type CAM3-S straight-through joints are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR). They allow the connection of cables with different cross sections, conductive materials, semi-conducting layers (graphite-coated, removable or strippable) and screening (wire or tape screen). Suitable for compression connectors. Characteristics • Reliable stress control due to flexible silicone stress control elements • Wide conductor and cross-section range • Ready for immediate operation • Quick, safe and easy assembly Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included • Joints with a range of Um = 12 kV must be used for cables of Um = 7.2 kV. (Check minimum diameter over conductor insulation). L mm Type min. Ø over conductor mm U0/U (Um) 6/10 (12)kV - 12.7/22 (24)kV 16-120 1200 CAM3-S 24kV 70-240 1200 U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 50-240 1200 CAM3-S 12kV 150-400 1200 U0/U (Um) 8.7/15 (17.5)kV 35-150 1200 CAM3-S 17kV 95-300 1200 14.7 19.9 160 160 14.7 19.9 160 160 14.7 19.9 160 160 Appropriate compression connectors must be ordered separately. Armour continuity kit for armoured cable available to order. 62 www.cellpack.com max. connector length mm L = Length Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Silicone joint body with integrated semi-conducting layer (individually tested) • Copper braid tube • Pressure spring • Lubricant • Protective gloves • Silicone stress-control elements • Assembly instructions Nominal cross section mm² 12kV 17.5kV Art.-No. 24kV 16 - 120 201382 70 - 240 201374 201375 201377 50 - 240 150 - 400 35 - 150 95 - 300 201379 201381 Termination for 3-core cables Medium Voltage 2013 CHE-3I(A) Three-core indoor termination for all 3-core polymeric cables Type CHE-3I(A) terminations are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (copper wire or tape). Dimensions Characteristics • Flexible silicone stress control elements ensure reliable stress control under all operating conditions • Combination of slip-on and heat-shrink components • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Application • Indoor Note • Cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). min. Ø over conductor L insulation after Type mm removal of outer semi-conducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 10-25 300 9.9 25-95 300 12.6 CHE-3I(A) 12kV 95-240 300 17.3 150-400 300 19.9 U0/U (Um) 8.7/15 (17.5)kV 16-50 300 12.6 70-240 300 17.3 CHE-3I(A) 17kV 150-300 300 19.9 185-400 300 23.1 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 10-35 300 12.6 25-95 300 17.3 CHE-3I(A) 24kV 70-240 300 19.9 120-300 300 23.1 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 500 19.9 500 23.1 CHE-3I(A) 36kV 50-150 150-400 500 27.3 Number of ØS sheds mm per phase Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Tracking-resistant heat-shrink tubing • Heat-shrink tube • Silicone stress-control elements • Silicone sheds • Pressure spring • Silicone stress control element • Assembly accessories • Sealing tape • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) Nominal cross section mm² 12kV 17.5kV 24kV 36kV 146228 146216 146217 146218 10 - 25 25 - 95 95 - 240 150 - 400 1 1 1 1 85 85 85 85 1 1 1 1 85 85 85 85 2 2 2 85 85 115 Art.-No. 195365 171761 171762 171763 16 - 50 70 - 240 150 - 300 185 - 400 10 - 35 25 - 95 70 - 240 120 - 300 146300 146302 146301 146297 35 - 70 146158 50 - 150 146159 150 - 400 146160 Appropriate cable lugs must be ordered separately. Type EGA earthing kit for cables with tape screen and armouring must be ordered separately. www.cellpack.com 63 Cable accessories for screened cables L = Length Ø S = Diameter of cable shed Termination for 3-core cables Medium Voltage 2013 CHE-3F(A) Three-core outdoor termination for all 3-core polymeric cables Type CHE-3F(A) terminations are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (copper wire or tape). Dimensions Cable accessories for screened cables L = Length Ø S = Diameter of cable shed Characteristics • Flexible silicone stress control elements ensure reliable stress control under all operating conditions • Combination of slip-on and heat-shrink components • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Application • Outdoor Note • Cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Spreader cap • Tracking-resistant heat-shrink tubing • Silicone stress-control elements • Silicone sheds • Sealing tape • Pressure spring • Assembly accessories • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) min. Ø Number Nominal cross section over conductor of mm² L insulation after ØS Type sheds mm removal of outer mm per 12kV 17.5kV 24kV 36kV semi-conducting phase layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 10-25 300 9.9 1 80 10 - 25 25-95 300 12.6 1 85 25 - 95 CHE-3F(A) 12kV 95-240 300 17.3 1 85 95 - 240 150-400 300 19.9 1 85 150 - 400 U0/U (Um) 8.7/15 (17.5)kV 16-50 500 12.6 2 85 16 - 50 70-240 500 17.3 2 85 70 - 240 CHE-3F(A) 17kV 150-300 500 19.9 2 85 150 - 300 185-400 500 23.1 2 85 185 - 400 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 10-35 500 12.6 3 85 10 - 35 25-95 500 17.3 3 85 25 - 95 CHE-3F(A) 24kV 70-240 500 19.9 3 85 70 - 240 120-300 500 23.1 3 85 120 - 300 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 700 19.9 4 85 35 - 70 700 23.1 4 85 50 - 150 CHE-3F(A) 36kV 50-150 150-400 700 27.3 4 115 150 - 400 Appropriate cable lugs must be ordered separately. Type EGA earthing kit for cables with tape screen and armouring must be ordered separately. 64 www.cellpack.com Art.-No. 146226 146220 146222 146224 195366 171756 171757 146296 146303 146304 146306 146298 146234 146235 146242 Termination for 3-core cables Medium Voltage 2013 CHE-3I(B) Three-core indoor termination for all 3-core polymeric cables Type CHE-3I(B) terminations are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (copper wire or tape). Dimensions Characteristics • Flexible silicone stress control elements ensure reliable stress control under all operating conditions • Combination of slip-on and heat-shrink components • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Tracking resistant spreader cap • Tracking-resistant heat-shrink tubing • Silicone stress-control elements • Silicone sheds • Pressure spring • Assembly accessories • Sealing tape • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) Application • Indoor Note • Cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). min. Ø over conductor L insulation after Type mm removal of outer semi-conducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 10-25 350 9.9 25-95 350 12.6 CHE-3I(B) 12kV 95-240 350 17.3 150-400 350 19.9 U0/U (Um) 8.7/15 (17.5)kV 25-50 400 12.6 70-240 400 17.3 CHE-3I(B) 17kV 150-300 400 19.9 185-400 400 23.1 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 10-35 500 12.6 25-95 500 17.3 CHE-3I(B) 24kV 70-240 500 19.9 120-400 500 23.1 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 650 19.9 650 23.1 CHE-3I(B) 36kV 50-150 150-400 650 27.3 Number of ØS sheds mm per phase Nominal cross section mm² 12kV 17.5kV 24kV 36kV 184796 173134 173132 180522 10 - 25 25 - 95 95 - 240 150 - 400 182731 182732 182733 182734 25 - 50 70 - 240 150 - 300 185 - 400 1 1 1 1 85 85 85 85 2 2 2 85 85 115 Art.-No. 10 - 35 25 - 95 70 - 240 120 - 400 184797 184798 184799 184800 35 - 70 184801 50 - 150 184802 150 - 400 184803 Appropriate cable lugs must be ordered separately. Type EGA earthing kit for cables with tape screen must be ordered separately. www.cellpack.com 65 Cable accessories for screened cables L = Length Ø S = Diameter of cable shed Termination for 3-core cables Medium Voltage 2013 CHE-3F(B) Three-core outdoor termination for all 3-core polymeric cables Type CHE-3F(B) terminations are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (copper wire or tape). Dimensions Cable accessories for screened cables L = Length Ø S = Diameter of cable shed Characteristics • Flexible silicone stress control elements ensure reliable stress control under all operating conditions • Combination of slip-on and heat-shrink components • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Application • Outdoor Note • Cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Tracking-resistant heat-shrink tubing • Silicone stress-control elements • Silicone sheds • Sealing tape • Pressure spring • Assembly accessories • Tracking resistant spreader cap • Assembly instructions Tests • CENELEC HD 629.1 (DIN VDE 0278, part 629-1) min. Ø Number Nominal cross section over conductor of mm² L insulation after ØS Type sheds mm removal of outer mm per 12kV 17.5kV 24kV 36kV semi-conducting phase layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 10-25 700 9.9 1 80 10 - 25 25-95 700 12.6 1 85 25 - 95 CHE-3F(B) 12kV 95-240 700 17.3 1 85 95 - 240 150-400 700 19.9 1 85 150 - 400 U0/U (Um) 8.7/15 (17.5)kV 25-50 700 12.6 2 85 25 - 50 70-240 700 17.3 2 85 70 - 240 CHE-3F(B) 17kV 150-300 700 20.9 2 85 150 - 300 185-400 700 23.1 2 85 185 - 400 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 10-35 850 12.6 3 85 10 - 35 25-95 850 17.3 3 85 25 - 95 CHE-3F(B) 24kV 70-240 850 20.9 3 85 70 - 240 120-400 850 23.1 3 85 120 - 400 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 850 22.5 4 85 35 - 70 850 23.1 4 85 50 - 150 CHE-3F(B) 36kV 50-150 150-400 850 27.3 4 115 150 - 400 Appropriate cable lugs must be ordered separately. Type EGA earthing kit for cables with tape screen must be ordered separately. 66 www.cellpack.com Art.-No. 184805 184806 184807 184808 182735 182736 182737 182738 184472 184809 184811 184812 184813 184815 184816 Termination for 3-core cables Medium Voltage 2013 CAE-3I Three-core indoor termination for all 3-core polymeric cables Type CAE-3I terminations are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (wire or tape screen). Suitable for compression cable lugs. Dimensions L = Length Ø S = Diameter of cable shed Application • Indoor Note • Compression cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). min. Ø over conductor L insulation after Type mm removal of outer semi-conducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 95-240 270 17.3 CAE-3I 12kV 150-400 270 19.9 U0/U (Um) 8.7/15 (17.5)kV 50-185 270 17.3 CAE-3I 17kV 95-240 270 19.9 150-400 270 23.1 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 35-120 270 17.3 CAE-3I 24kV 70-240 270 19.9 120-400 270 23.1 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 16-95 325 19.9 325 23.1 CAE-3I 36kV 50-240 120-400 325 27.3 Number of ØS sheds mm per phase 1 1 87 90 1 1 1 87 90 93 1 1 1 87 90 93 4 4 4 90 93 97 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • 3 one-piece slip-on silicone terminations with integrated stress control element • Silicone tube • Silicone cold-shrink spreader cap • Assembly accessories • Sealing tape • Assembly instructions Nominal cross section mm² 12kV 17.5kV 24kV Cable accessories for screened cables Characteristics • Wide cross-section range • Silicone slip-on components for quick, safe and easy assembly • Ready for immediate operation Art.-No. 36kV 199170 199171 95 - 240 150 - 400 199173 199174 199175 50 - 185 95 - 240 150 - 400 35 - 120 70 - 240 120 - 400 199177 199178 199179 16 - 95 199180 50 - 240 199182 120 - 400 199181 Appropriate compression cable lugs must be ordered separately. Type EGA earthing kit for cables with tape screen must be ordered separately. www.cellpack.com 67 Termination for 3-core cables Medium Voltage 2013 CAE-3F Three-core outdoor termination for all 3-core polymeric cables Type CAE-3F terminations are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (wire or tape screen). Suitable for compression cable lugs. Dimensions Cable accessories for screened cables L = Length Ø S = Diameter of cable shed Characteristics • Wide cross-section range • Silicone slip-on components for quick, safe and easy assembly • Ready for immediate operation min. Ø over conductor L insulation after Type mm removal of outer semi-conducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 95-240 325 17.3 CAE-3F 12kV 150-400 325 19.9 U0/U (Um) 8.7/15 (17.5)kV 50-185 325 17.3 CAE-3F 17kV 95-240 325 19.9 150-400 325 23.1 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 35-120 325 17.3 CAE-3F 24kV 70-240 325 19.9 120-400 325 23.1 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 50-240 440 23.1 CAE-3F 36kV 120-400 440 27.3 Number of ØS sheds mm per phase Nominal cross section mm² 12kV 4 4 87 95 - 240 90 150 - 400 4 4 4 87 87 93 4 4 4 87 90 93 5 5 93 97 Appropriate compression cable lugs must be ordered separately. Type EGA earthing kit for cables with tape screen must be ordered separately. 68 www.cellpack.com Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • 3 one-piece slip-on silicone terminations with integrated stress control element • Silicone tube • Silicone cold-shrink spreader cap • Assembly accessories • Sealing tape • Assembly instructions Application • Outdoor Note • Compression cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). 17.5kV 24kV Art.-No. 36kV 199201 199202 199204 199205 199206 50 - 185 95 - 240 150 - 400 35 - 120 70 - 240 120 - 400 199208 199209 199210 50 - 240 199211 120 - 400 199212 Termination for 3-core cables Cable accessories for screened cables Medium Voltage 2013 www.cellpack.com 69 Medium Voltage 2013 We help you achieve the highest standards 70 www.cellpack.com Medium Voltage 2013 Page Belted cables Transition joints 72 Straight-through joints 76 Terminations 77 Cable accessories for paper-insulated cables Page Hoechstaedterkabel Transition joints 79 Straight-through joints 81 Terminations 82 Three-core single lead sheath cables Transition joints 84 Straight-through joints 86 Terminations 87 www.cellpack.com 71 Transition joints Medium Voltage 2013 M...MSPB6 Three-core transition joint Cable accessories for paper-insulated cables from belted cable to polymeric cable without external conductive layer Type M.MSPB6 transition joints are suitable for transitions between paper-insulated lead cables and three-core cables with plastic insulation (PVC, PE, XLPE, EPR) and no outer semi-conducting layer. They allow the connection of cables with different cross Type M.MSPB6 transition joints are suitable for transitions between paper-insulated lead cables and three-core cables with plastic insulation (PVC, PE, XLPE, EPR) and no outer semi-conducting layer. They allow the connection of cables with different cross sections, conductive materials and structure. They do not contain any substances which inhibit paint wetting and are suitable for use in the automotive industry. Dimensions Characteristics • Quick, safe and easy assembly • Resistant to chemical agents • Longitudinally and transversely watertight • High mechanical strength Scope of delivery • Distance sleeve • Hydrolysis-resistant PUR type EG cast-resin, containing the correct volume ready for mixing • Transparent plastic moulds • Spreader cap • Armour continuity kit • Fill and air-release funnel • Heat-shrinkable tubing for sealing • Assembly accessories • Assembly instructions Type L1 mm L2 mm Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Connectors not included D1 mm D2 mm U0/U (Um) 3.6/6 (7.2)kV - 3.8/6.6 (7.2)kV M4MSPB6 432 384 28.9 52 M5MSPB6 550 503 41.6 62 Appropriate connectors must be ordered separately. 72 www.cellpack.com L = Length D = Diameter D3 mm Cable-Ø mm 3x Nominal cross section per conductor Polymeric cable mm² Art.-No. 90 110 29 - 55 42 - 65 25 - 70 70 - 120 124334 124335 Transition joints Medium Voltage 2013 CHMPRSV 3-1 Transition joint with screw connectors, from belted cable to polymeric cables Type CHMPRSV3-1 hybrid transition joints for transition to three single-core plasticinsulated cables are suitable for both paper-insulated lead cables and Hochstädter cables up to 17.5 kV. With screw connectors. Dimensions Characteristics • Reliable stress control due to flexible silicone stress control elements • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation • Suitable for a wide range of applications due to innovative integrated screw connector Type Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Incl. Screw connectors min. Ø over conductor L insulation after removal of outer mm semi-conducting layer mm U0/U (Um) 6/10 (12)kV - 8.7 /15 (17.5)kV 35-95 1200 70-150 1200 CHMPRSV3-1 17kV 95-240 1200 240-400 1200 12.6 17.3 17.3 23.1 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Spreader cap • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Oil barrier tubing • Heat-shrink tubing • Silicone stress-control elements • Earthing wire • Copper braid tape • Pressure spring • Assembly accessories • Sealing tape • Stress control filling tape (blue) • Fire protection wrap • Screw connector for copper-wire screen • Innovative screw connector with conductive sheath • Assembly instructions Nominal cross section mm² 12kV 17.5kV 50 - 95 95 - 150 95 - 240 240 - 400 35 - 95 70 - 150 95 - 240 240 - 400 Art.-No. 264988 265205 264769 265501 www.cellpack.com 73 Cable accessories for paper-insulated cables L = Length Transition joints Medium Voltage 2013 CHMPR 3-1 Transition joint from belted cable to polymeric cables Type CHMPR3-1 hybrid transition joints for transition to three single-core plasticinsulated cables are suitable for both paper-insulated lead cables and Hochstädter cables up to 17.5 kV. Padding kits for paper-insulated cables are available for downwards enlargement of the operational area. Suitable for Compression connectors. Dimensions L = Length Cable accessories for paper-insulated cables Characteristics • Reliable stress control due to flexible silicone stress control elements • Wide conductor and cross-section range • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Spreader cap • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Oil barrier tubing • Heat-shrink tubing • Silicone stress-control elements • Earthing wire • Copper braid tape • Pressure spring • Assembly accessories • Sealing tape • Stress control filling tape (blue) • Fire protection wrap • Assembly instructions min. Ø 12 kV 17.5 kV over conductor insulation after L max. max. Nominal max. max. Type removal of Nominal mm cross Ø of connector cross Ø of connector outer semisection connector length section connector length conducting mm² mm mm mm² mm mm layer mm U0/U (Um) 6/10 (12)kV - 8.7 /15 (17.5)kV 35-50 1100 12.6 50 - 95 25 145 35 - 50 20 110 CHMPR3-1 70-240 1100 17.3 95 - 300 34 145 70 - 240 34 145 17kV 240-400 1100 23.1 300 - 400 42 170 240 - 400 42 170 Art.-No. 197603 197604 197606 Appropriate connectors must be ordered separately. Padding kits must be ordered separately. Padding kit PS(G+H)17/1 (Art.-No.197690) to be used with Art.-No. 197604 sur 35-50mm² (17.5kV) and 35-70mm² (12kV). 74 www.cellpack.com Transition joints Medium Voltage 2013 CHMPR 3 Transition joint from belted cable to polymeric cables Type CHMPR3 hybrid transition joints for transition to three-core plastic-insulated cables are suitable for both paper-insulated lead cables and Hochstädter cables up to 17.5 kV. Padding kits for paper-insulated cables are available for downwards enlargement of the operational area. Suitable for Compression connectors. Dimensions Characteristics • Reliable stress control due to flexible silicone stress control elements • Quick, safe and easy assembly • Ready for immediate operation • Wide cross-section range Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Spreader cap • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Oil barrier tubing • Heat-shrink tubing • Silicone stress-control elements • Earthing wire • Copper braid tape • Pressure spring • Assembly accessories • Sealing tape • Stress control filling tape (blue) • Fire protection wrap • Assembly instructions min. Ø 12 kV 17 kV over conductor insulation after L Nominal max. max. Nominal max. max. Type removal of Art.-No. mm cross Ø of connector cross Ø of connector outer semisection connector length section connector length conducting mm² mm mm mm² mm mm layer mm U0/U (Um) 6/10 (12)kV - 8.7 /15 (17.5)kV 35-50 1400 12.6 50 - 95 25 145 35 - 50 20 110 197618 CHMPR3 70-240 1400 17.3 95 - 300 34 145 70 - 240 34 145 197619 17kV 240-400 1400 23.1 300 - 400 42 170 240 - 400 42 170 197620 Appropriate compression connectors must be ordered separately. Padding kits must be ordered separately. Padding kit PS(G+H)17/1 (Art.-No.197690) tob e used with Art.-No. 197619 sur 35-50mm² (17.5kV and resp. 35-70mm² (12kV). www.cellpack.com 75 Cable accessories for paper-insulated cables Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included L = Length Straight-through joints Medium Voltage 2013 CHMPPR3 Straight-through joint for belted cables up to 17.5 kV (MIND) Type CHMPPR3 hybrid transition joints are suitable for belted cables and Hochstädter cables up to 17.5 kV. Suitable for compression connectors. Dimensions L = Length Cable accessories for paper-insulated cables Characteristics • Quick, safe and easy assembly • Ready for immediate operation • Wide cross-section range Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Spreader cap • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Oil barrier tubing • Heat-shrink tubing • Earthing wire • Copper braid tape • Pressure spring • Assembly accessories • Sealing tape • Stress control filling tape (blue) • Fire protection wrap • Assembly instructions min. Ø 12 kV 17.5kV over conductor insulation after L Nominal max. max. Nominal max. max. Type removal of mm cross Ø of connector cross Ø of connector outer semisection connector length section connector length conducting mm² mm mm mm² mm mm layer mm U0/U (Um) 6/10 (12)kV - 8.7 /15 (17.5)kV 35-50 1400 15.2 50 - 95 25 145 35 - 50 20 110 CHMPPR3 70-240 1400 17.9 95 - 300 34 145 70 - 240 34 145 17kV 240-400 1400 26.3 300 - 400 42 170 240 - 400 42 170 Appropriate compression connectors must be ordered separately. 76 www.cellpack.com Art.-No. 197658 197659 197660 Terminations Medium Voltage 2013 CHEP-3I Indoor termination for belted cables up to 17.5 kV (MIND) Type CHEP-3I indoor terminations are suitable for belted cables up to 17.5 kV for MIND cables only. For cables with draining compound please contact us. Dimensions L = Length Type Application • Indoor Note • Cable lugs not included L mm U0/U (Um) 6/10 (12)kV - 8.7 /15 (17.5)kV 16-50 500 25-240 500 CHEP-3I 12kV 95-300 500 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Tracking resistant spreader cap • Tracking-resistant heat-shrink tubing • Earthing kit • Assembly accessories • Sealing tape • Assembly instructions Nominal cross section mm² min. Ø over conductor mm 12 kV 17.5kV 9.9 13.2 16.5 70 - 240 120 - 400 16 - 50 25 - 240 95 - 300 Art.-No. 197515 197516 197517 Appropriate cable lugs must be ordered separately. www.cellpack.com 77 Cable accessories for paper-insulated cables Characteristics • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Terminations Medium Voltage 2013 CHEP-3F Outdoor termination for belted cables up to 17.5 kV (MIND) Type CHEP-3F outdoor terminations are suitable for belted cables up to 17.5 kV for MIND cables only. For cables with draining compound please contact us. Dimensions L = Length Ø S = Diameter of cable shed Cable accessories for paper-insulated cables Characteristics • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation L mm Type Application • Outdoor Note • Cable lugs not included min. Ø over conductor mm U0/U (Um) 6/10 (12)kV - 8.7 /15 (17.5)kV 16-50 500 9.9 25-240 500 13.2 CHEP-3F 17kV 95-300 500 16.5 Appropriate cable lugs must be ordered separately. 78 www.cellpack.com Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Tracking resistant spreader cap • Tracking-resistant heat-shrink tubing • Silicone sheds • Earthing kit • Assembly accessories • Sealing tape • Assembly instructions Number of sheds per phase ØS mm 2 2 2 80 85 85 Nominal cross section mm² 12 kV 17.5kV 70 - 240 16 - 50 25 - 240 95 - 300 Art.-No. 197537 197538 197539 Transition joints Medium Voltage 2013 CHMP(H) 3-1 Transition joint for H-cables to polymeric cables Type CHMP(H)3-1 hybrid transition joints for transition to three single-core plasticinsulated cables are suitable for Hochstädter cables up 24 to 36 kV. Padding kits for paper-insulated cables are available for downwards enlargement of the operational area. Suitable for compression connectors. Dimensions Characteristics • Reliable stress control due to flexible silicone stress control elements • Wide conductor and cross-section range • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Spreader cap • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Oil barrier tubing • Heat-shrink tubing • Silicone stress-control elements • Earthing wire • Copper braid tape • Pressure spring • Assembly accessories • Sealing tape • Stress control filling tape (blue) • Fire protection wrap • Assembly instructions min. Ø Nominal cross section over conductor max. max. mm² L insulation after Ø of connector Type Art.-No. mm removal of outer connector length 24kV 36kV semi-conducting mm mm layer mm U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-35 1200 12.6 15 100 16 - 35 197607 35-70 1200 17.3 20 110 35 - 70 197608 CHMP(H)3-1 24 kV 95-240 1200 19.9 34 145 95 - 240 197609 185-300 1200 23.1 42 145 185 - 300 197610 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-50 1200 19.9 20 110 35 - 50 197614 1200 23.1 28 145 70 - 150 197616 CHMP(H)3-1 36 kV 70-150 150-300 1200 27.3 36 145 150 - 300 197617 Appropriate compression connectors must be ordered separately. Padding kits must be ordered separately. Padding kit PS(H)24/1 (Art.-No.197692) to be used with Art.-No. 197609 sur 35-70mm² (24kV) and 35-70mm² (24kV). www.cellpack.com 79 Cable accessories for paper-insulated cables Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included L = Length Transition joints Medium Voltage 2013 CHMP(H) 3 Transition joint Cable accessories for paper-insulated cables for H-cables to polymeric cables Type CHMP(H)3 hybrid transition joints for transition to three-core plastic-insulated cables are suitable for Hochstädter cables up 24 to 36 kV. Padding kits for paper-insulated cables are available for downwards enlargement of the operational area. Suitable for compression connectors. Dimensions Characteristics • Reliable stress control due to flexible silicone stress control elements • Quick, safe and easy assembly • Ready for immediate operation • Wide cross-section range Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Spreader cap • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Oil barrier tubing • Heat-shrink tubing • Silicone stress-control elements • Earthing wire • Copper braid tape • Pressure spring • Assembly accessories • Sealing tape • Stress control filling tape (blue) • Fire protection wrap • Assembly instructions Type U0/U (Um) 12/20 (24)kV 16-35 35-70 CHMP(H)3 24kV 95-240 185-300 U0/U (Um) 18/30 (36)kV 35-50 70-150 CHMP(H)3 36kV 150-300 Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included min. Ø over conductor L insulation after mm removal of outer semi-conducting layer mm 12.7/22 (24)kV 1400 12.6 1400 17.3 1400 19.9 1400 23.1 19/33 (36)kV 1400 19.9 1400 23.1 1400 27.3 L = Length max. max. Ø of connector connector length mm mm 15 20 34 42 100 110 145 145 20 28 36 110 145 145 Nominal cross section mm² Art.-No. 24kV 36kV 197621 197622 197623 197624 16 - 35 35 - 70 95 - 240 185 - 300 35 - 50 70 - 150 150 - 300 197625 197626 197627 Appropriate compression connectors must be ordered separately. Padding kits must be ordered separately. Padding kit PS(H)24/1 (Art.-No.197692) to be used with Art.-No. 197623 sur 35-70mm² (24kV) and 35-70mm² (24kV). 80 www.cellpack.com Straight-through joints Medium Voltage 2013 CHMPP(H)3 Straight-through joint for H-cables from 24 up to 36 kV Type CHMPP(H)3 hybrid transition joints are suitable for Hochstädter cables up to 24 to 36 kV. Padding kits for paper-insulated cables are available for downwards enlargement of the operational area. Suitable for compression connectors. Dimensions Characteristics • Quick, safe and easy assembly • Ready for immediate operation • Wide cross-section range Type U0/U (Um) 12/20 CHMPP(H)3 24kV U0/U (Um) 18/30 CHMPP(H)3 36kV Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Spreader cap • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Oil barrier tubing • Heat-shrink tubing • Silicone stress-control elements • Earthing wire • Copper braid tape • Pressure spring • Assembly accessories • Sealing tape • Spacers • Stress control filling tape (blue) • Fire protection wrap • Assembly instructions min. Ø over conductor max. max. L insulation after Ø of connector mm removal of outer connector length semi-conducting mm mm layer mm (24)kV - 12.7/22 (24)kV 16-35 1400 16.5 15 100 35-70 1400 17.4 20 110 95-240 1400 21.6 34 145 185-300 1400 25.8 42 145 (36)kV - 19/33 (36)kV 35-50 1400 21.4 20 110 70-150 1400 24 28 145 150-300 1400 28.2 36 145 Nominal cross section mm² Art.-No. 24kV 36kV 197661 197662 197663 197664 16 - 35 35 - 70 95 - 240 185 - 300 35 - 50 70 - 150 150 - 300 197665 197666 197667 Appropriate compression connectors must be ordered separately. www.cellpack.com 81 Cable accessories for paper-insulated cables L = Length Terminations Medium Voltage 2013 CHEP(H)-3I Indoor termination for H-cables from 24 up to 36 kV Type CHEP(H)-3F outdoor terminations are suitable for Hoechstaedter cables from 24 up to 36 kV for MIND cables only. For cables with draining compound please contact us. Dimensions L = Length Ø S = Diameter of cable shed Cable accessories for paper-insulated cables Characteristics • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation L mm Type min. Ø over conductor mm U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-35 500 12.6 50-150 500 17.3 CHEP(H)-3I 24kV 70-240 500 19.9 120-300 500 23.1 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 650 19.9 CHEP(H)-3I 36kV 50-240 650 23.1 Appropriate cable lugs must be ordered separately. 82 www.cellpack.com Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Tracking-resistant heat-shrink tubing • Conductive spreader cap • Conductive heat-shrink tubing • Oil barrier tubing • Filling tape • Silicone sheds • Earthing wire • Pressure spring • Assembly instructions Application • Indoor Note • Cable lugs not included Number of sheds per phase ØS mm 1 1 1 1 80 85 85 85 2 2 85 85 Nominal cross section mm² 24kV Art.-No. 36kV 197531 197532 197533 197534 16 - 35 50 - 150 70 - 240 120 - 300 35 - 70 50 - 240 197535 197536 Terminations Medium Voltage 2013 CHEP(H)-3F Outdoor termination for H-cables from 24 up to 36 kV Type CHEP(H)-3F outdoor terminations are suitable for Hoechstaedter cables from 24 up to 36 kV for MIND cables only. For cables with draining compound please contact us. Dimensions Characteristics • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Type L mm Application • Outdoor Note • Cable lugs not included min. Ø over conductor mm U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-35 850 12.6 50-150 850 17.3 CHEP(H)-3F 24kV 70-240 850 19.9 120-300 850 23.1 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 850 19.9 CHEP(H)-3F 36kV 50-240 850 23.1 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Tracking-resistant heat-shrink tubing • Conductive spreader cap • Oil barrier tubing • Filling tape • Silicone sheds • Earthing wire • Pressure spring • Sealing tape • Oil-barrier stress control filling tape (blue) • Assembly instructions Number of sheds per phase ØS mm 3 3 3 3 80 85 85 85 4 4 85 85 Nominal cross section mm² 24kV Art.-No. 36kV 197543 197544 197545 197546 16 - 35 50 - 150 70 - 240 120 - 300 35 - 70 50 - 240 197547 197548 Appropriate cable lugs must be ordered separately. www.cellpack.com 83 Cable accessories for paper-insulated cables L = Length Ø S = Diameter of cable shed Transition joints Medium Voltage 2013 CHMP(3Pb) 3-1 Transition joint for 3-core single lead sheath cables to polymeric cables Type CHMP(3Pb)3-1 hybrid transition joints for transition to three single-core cables are suitable for all three-core lead sheath cables up to 36 kV. Padding kits for paper-insulated cables are available for downwards enlargement of the operational area. Suitable for compression connectors. Dimensions L = Length Cable accessories for paper-insulated cables Characteristics • Reliable stress control due to flexible silicone stress control elements • Wide conductor and cross-section range • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included Scope of delivery • Spreader cap • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Oil barrier tubing • Heat-shrink tubing • Silicone stress-control elements • Earthing wire • Copper braid tape • Pressure spring • Assembly accessories • Sealing tape • Stress control filling tape (blue) • Fire protection wrap • Assembly instructions min. Ø over 12 kV 17 kV conductor L insulation after Nominal max. max. Nominal max. max. Type Art.-No. mm removal of outer cross Ø of connector cross Ø of connector semi-conducting section connector length section connector length layer mm mm² mm mm mm² mm mm U0/U (Um) 6/10 (12)kV - 8.7 /15 (17.5)kV 25-50 1200 12.6 50 - 95 25 110 25 - 50 20 110 197628 17.3 95 - 185 32 140 70 - 150 25 140 198782 CHMP(3Pb)3-1 70-150 1200 17 kV 120-240 1200 19.9 150 - 300 36 150 120 - 240 34 150 197629 240-300 1200 23.1 300 - 400 40 170 240 - 300 40 150 197630 min. Ø over conductor max. insulation after max. Ø of L connector Type removal of outer connector mm length semi-conducting mm mm layer mm U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-25 1200 12.6 20 100 1200 17.3 25 110 CHMP3Pb3-1 35-95 24kV 95-240 1200 19.9 34 150 185-300 1200 23.1 40 150 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-50 1200 19.9 20 110 CHMP3Pb3-1 70-150 1200 23.1 25 150 36kV 150-300 1200 27.3 38 160 Nominal cross section mm² 24kV Art.-No. 36kV 197631 197632 197633 197634 16 - 25 35 - 95 95 - 240 185 - 300 35 - 50 70 - 150 150 - 300 197635 197636 197637 Appropriate compression connectors must be ordered separately. Padding kits must be ordered separately. Padding kit PS(3Pb+Pb), (Art.-No.197699) to be used with Art.-No. 197633 sur 35-70mm² (24kV). Please use the padding kit PS(3Pb+Pb), (Art.-No.197701) for the following case: for Art.-No. 197636 sur 35-70mm² (36kV). Please use the padding kit PS(3Pb+Pb), (Art.Nr.197702) for the following case: for Art.-No. 197637 sur 70-150mm² (36kV). 84 www.cellpack.com Transition joints Medium Voltage 2013 CHMP(3Pb) 3 Transition joint for 3-core single lead sheath cables to polymeric cables Type CHMPP(3Pb)3 hybrid transition joints are suitable for all three-core lead sheath Dimensions cables up to 36 kV. Padding kits for paper-insulated cables are available for downwards enlargement of the operational area. Suitable for compression connectors. Characteristics • Reliable stress control due to flexible silicone stress control elements • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Spreader cap • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Oil barrier tubing • Heat-shrink tubing • Silicone stress-control elements • Earthing wire • Copper braid tape • Pressure spring • Assembly accessories • Sealing tape • Stress control filling tape (blue) • Fire protection wrap • Assembly instructions min. Ø 12 kV 17.5 kV over conductor L insulation after Nominal max. max. Nominal max. max. Type mm removal of outer cross Ø of connector cross Ø of connector semi-conducting section connector length section connector length layer mm mm² mm mm mm² mm mm U0/U (Um) 6/10 (12)kV - 8.7 /15 (17.5)kV 25-50 1400 12.6 50 - 95 25 110 25 - 50 20 110 17.3 95 - 185 32 140 70 - 150 25 140 CHMP(3Pb)3 70-150 1400 17kV 120-240 1400 19.9 150 - 300 36 150 120 - 240 34 150 240-300 1400 23.1 300 - 400 40 170 240 - 300 40 150 min. Ø over conductor max. max. insulation after L Ø of connector Type removal of outer mm connector length semi-conducting mm mm layer mm U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-25 1400 12.6 20 100 1400 17.3 25 110 CHMP(3Pb)3 35-95 24kV 95-240 1400 19.9 34 150 185-300 1400 23.1 40 150 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-50 1400 19.9 20 110 CHMP(3Pb)3 70-150 1400 23.1 25 150 36kV 150-300 1400 27.3 38 160 Nominal cross section mm² 24kV Art.-No. 197638 198783 197639 197640 Art.-No. 36kV 197641 197642 197643 197644 16 - 25 35 - 95 95 - 240 185 - 300 35 - 50 70 - 150 150 - 300 197645 197646 197647 Appropriate compression connectors must be ordered separately. Padding kits must be ordered separately. Padding kit PS(3Pb+Pb), (Art.-No.197699) to be used with Art.-No. 197633 sur 35-70mm² (24kV). Please use the padding kit PS(3Pb+Pb), (Art.-No.197701) for the following case: for Art.-No. 197636 sur 35-70mm² (36kV). Please use the padding kit PS(3Pb+Pb), (Art.Nr.197702) for the following case: for Art.-No. 197637 sur 70-150mm² (36kV). www.cellpack.com 85 Cable accessories for paper-insulated cables L = Length Straight-through joints Medium Voltage 2013 CHMPP(3Pb)3 Straight-through joint for 3-core single lead sheath cables Type CHMPP(3Pb)3 hybrid transition joints are suitable for all three-core lead sheath cables up to 36 kV. Suitable for compression connectors. Dimensions L = Length Cable accessories for paper-insulated cables Characteristics • Quick, safe and easy assembly • Ready for immediate operation • Wide cross-section range Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Spreader cap • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Oil barrier tubing • Heat-shrink tubing • Silicone stress-control elements • Earthing wire • Copper braid tape • Pressure spring • Assembly accessories • Sealing tape • Stress control filling tape (blue) • Fire protection wrap • Assembly instructions 12 kV 17.5 kV min. Ø max. max. Nominal max. max. Nominal L over Type Art.-No. cross Ø of connector cross Ø of connector mm conductor section connector length section connector length mm mm² mm mm mm² mm mm U0/U (Um) 6/10 (12)kV - 8.7 /15 (17.5)kV 25-50 1400 14.1 50 - 95 25 110 25 - 50 20 110 197668 17.6 95 - 185 32 140 70 - 150 25 140 198784 CHMPP(3Pb)3 70-150 1400 12kV 120-240 1400 20.5 150 - 300 36 150 120 - 240 34 150 197669 240-300 1400 25.6 300 - 400 40 170 240 - 300 40 150 197670 min. Ø L over conductor mm mm Type U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-25 1400 15.4 1400 17.4 CHMPP(3Pb)3 35-95 24kV 95-240 1400 21.6 185-300 1400 25.8 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-50 1400 21.4 CHMPP(3Pb)3 70-150 1400 24 36kV 150-300 1400 28.2 max. Ø of connector mm max. connector length mm 20 25 34 40 100 110 150 150 20 25 36 110 150 160 Appropriate compression connector must be ordered separately. 86 www.cellpack.com Nominal cross section mm² 24kV Art.-No. 36kV 197671 197672 197673 197674 16 - 25 35 - 95 95 - 240 185 - 300 35 - 50 70 - 150 150 - 300 197675 197676 197677 Terminations Medium Voltage 2013 CHEP(3Pb)-3I Indoor termination for 3-core single lead sheath cables Type CHEP(3Pb)-3I indoor terminations are suitable for three-core single lead sheath cables from 24 up to 36 kV – for MIND cables only. For cables with draining compound please contact us. Dimensions L = Length Ø S = Diameter of cable shed Type Application • Indoor Note • Cable lugs not included L mm min. Ø over conductor mm U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-35 450 50-150 450 CHEP(3Pb)-3I 24kV 70-240 450 120-300 450 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 600 CHEP(3Pb)-3I 36kV 95-240 600 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Tracking-resistant heat-shrink tubing • Oil barrier tubing • Silicone sheds • Sealing tape • Oil-barrier stress control filling tape (blue) • Earthing wire • Pressure spring • Assembly instructions Number of sheds per phase ØS mm 12.2 17.2 19.9 23.1 1 1 1 1 80 85 85 85 19.9 23.1 2 2 85 85 Nominal cross section mm² 24kV Art.-No. 36kV 197555 197556 197557 197558 16 - 35 50 - 150 70 - 240 120 - 300 35 - 70 95 - 240 197559 197560 Appropriate cable lugs must be ordered separately. www.cellpack.com 87 Cable accessories for paper-insulated cables Characteristics • Combination of slip-on and heat-shrink components • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Terminations Medium Voltage 2013 CHEP(3Pb)-3F Outdoor termination for 3-core single lead sheath cables Type CHEP(3Pb)-3F outdoor terminations are suitable for three-core single lead sheath cables from 24 up to 36 kV – for MIND cables only. For cables with draining compound please contact us. Dimensions L = Length Ø S = Diameter of cable shed Cable accessories for paper-insulated cables Characteristics • Combination of slip-on and heat-shrink components • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation L mm Type min. Ø over conductor mm U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 16-35 600 50-150 600 CHEP(3Pb)-3F 24kV 70-240 600 120-300 600 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 35-70 750 CHEP(3Pb)-3F 36kV 95-240 750 Number of sheds per phase ØS mm 12.2 17.2 19.9 23.1 3 3 3 3 80 85 85 85 19.9 23.1 4 4 85 85 Appropriate cable lugs must be ordered separately. 88 www.cellpack.com Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Weatherproof spreader cap • Tracking-resistant heat-shrink tubing • Oil barrier tubing • Silicone sheds • Sealing tape • Oil-barrier stress control filling tape (blue) • Earthing wire • Pressure spring • Assembly instructions Application • Outdoor Note • Cable lugs not included Nominal cross section mm² 24kV Art.-No. 36kV 197567 197568 197569 197570 16 - 35 50 - 150 70 - 240 120 - 300 35 - 70 95 - 240 197571 197572 Terminations Cable accessories for paper-insulated cables Medium Voltage 2013 www.cellpack.com 89 Complete safety 90 www.cellpack.com Medium Voltage 2013 Medium Voltage 2013 Page Straight-through joints for single-core cables 92 Straight-through joints for 3-core cables 93 Terminations for single-core cables 94 Terminations for 3-core cables 96 Accessories 98 Cable accessories for screened cables according to British Standard www.cellpack.com 91 Straight-through joints for single-core cables Medium Voltage 2013 CHM(BS) Single-core straight-through joint Cable accessories for screened cables according to British Standard for all polymeric single-core cables Type CHM (BS) straight-through joints are suitable for all single-core plasticinsulated cables (PVC, PE, XLPE, EPR). They allow the connection of cables with different cross sections, conductive materials, semi-conducting layers (graphite-coated, removable or strippable) and screening (copper wire or tape). Suitable for compression connectors. Dimensions Characteristics • Reliable stress control due to flexible silicone stress control elements • Quick, safe and easy assembly • Ready for immediate operation • Wide cross-section range Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Thick wall heat-shrinkable insulation tubing • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Silicone stress-control elements • Copper braid tube • Pressure springs • Assembly accessories • Steel cage • Stress control filling tape (blue) • Assembly instructions Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included • Joints with a range of Um = 12 kV must be used for cables of Um = 7.2 kV. (Check minimum diameter over conductor insulation). L = Length min. Ø Nominal cross section over conductor max. mm² max. Ø of L insulation after connector Type connector Art.-No. mm removal of outer length mm semi-conducting mm 12kV 36kV layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV CHM(BS) 12kV 400-630 1100 27.3 60 360 400 - 630 253845 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 150-400 900 27.3 38 200 150 - 400 253844 CHM(BS) 36kV 500-800 1100 36.8 60 360 500 - 800 253843 Appropriate compression connectors must be ordered separately. 92 www.cellpack.com Straight-through joints for 3-core cables Medium Voltage 2013 CHM3(BS) Three-core straight-through joint for all 3-core polymeric cables Type CHM3(BS) straight-through joints are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR). They allow the connection of cables with different cross sections, conductive materials, semi-conducting layers (graphite-coated, removable or strippable) and screening (copper wire or tape). Suitable for compression connectors. Dimensions Characteristics • Reliable stress control due to flexible silicone stress control elements • For all cables with copper wire or tape screen • Quick, safe and easy assembly • Ready for immediate operation • Wide cross-section range Type Application • Indoor • Outdoor • Underground • Water • Installation ducts • Ductwork Note • Compression connectors not included • Joints with a range of Um = 12 kV must be used for cables of Um = 7.2 kV. (Check minimum diameter over conductor insulation). min. Ø over conductor max. max. insulation after Ø of connector L removal of mm connector length outer semimm mm conducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 35-95 1500 12.6 CHM3(BS) 95-240 1500 17.3 12kV 150-300 1500 19.9 U0/U (Um) 8.7/15 (17.5)kV 35-95 1500 12.6 CHM3(BS) 70-240 1500 17.3 17kV 120-300 1500 19.9 U0/U (Um) 12/20 (24)kV - 12.7/22 (24)kV 35-95 1500 17.3 CHM3(BS) 70-240 1500 19.9 24kV 150-300 1500 23.1 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 50-150 1500 23.1 CHM3(BS) 36kV 150-300 1500 27.3 19 29 32 90 125 125 19 29 32 90 125 125 19 29 32 90 125 125 23 32 105 125 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Thick wall heat-shrinkable insulation tubing • Thick wall heat-shrinkable outer tubing with hot melt adhesive • Silicone stress-control element • Copper braid tube • Pressure springs • Stress control filling tape (blue) • Assembly instructions • Steel cage • Assembly accessories Nominal cross section mm² Art.-No. 12kV 17.5kV 24kV 36kV 248770 248718 248717 35 - 95 95 - 240 150 - 300 249471 249474 249476 35 - 95 70 - 240 120 - 300 35 - 95 70 - 240 150 - 300 253917 253911 253929 50 - 150 248716 150 - 300 248719 Appropriate compression connectors must be ordered separately. www.cellpack.com 93 Cable accessories for screened cables according to British Standard L = Length Terminations for single-core cables Medium Voltage 2013 CHE-I (BS) Single-core indoor termination for all polymeric single-core cables Dimensions Cable accessories for screened cables according to British Standard Type CHE-I(BS) terminations are suitable for all single-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (copper wire or tape). L = Length Ø S = Diameter of cable shed Characteristics • Flexible silicone stress control elements ensure reliable stress control under all operating conditions • Combination of slip-on and heat-shrink components • Compatible with all cable lugs • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation L mm Type Application • Indoor Note • Cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). min. Ø over conductor insulation after removal of outer semi-conducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV CHE-I(BS) 12kV 400-630 400 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV CHE-I(BS) 36kV 150-400 600 www.cellpack.com ØS mm 27.3 27.3 Appropriate cable lugs must be ordered separately. 94 Number of sheds per phase Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • 1 Set for 3 phases • Tracking-resistant heat-shrink tubing • Silicone stress-control elements • Silicone sheds • Earthing kit • Sealing tape • Assembly instructions Nominal cross section mm² 12kV 36kV 253847 400 - 630 2 115 Art.-No. 150 - 400 253849 Terminations for single-core cables Medium Voltage 2013 CHE-F(BS) Single-core outdoor termination for all polymeric single-core cables L = Length Ø S = Diameter of cable shed Characteristics • Flexible silicone stress control elements ensure reliable stress control under all operating conditions • Combination of slip-on and heat-shrink components • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Type Application • Outdoor Note • Cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • 1 Set for 3 phases • Tracking-resistant heat-shrink tubing • Silicone stress-control elements • Silicone sheds • Earthing kit • Sealing tape • Assembly instructions min. Ø over conductor insulation after Number of ØS L removal of outer sheds per mm mm semi-conducting phase layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV CHE-F(BS) 12kV 400-630 400 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV CHE-F(BS) 36kV 150-400 800 27.3 1 115 27.3 4 115 Nominal cross section mm² 12kV Art.-No. 36kV 253848 400 - 630 150 - 400 253850 Appropriate cable lugs must be ordered separately. www.cellpack.com 95 Cable accessories for screened cables according to British Standard Dimensions Type CHE-F(BS) terminations are suitable for all single-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (copper wire or tape). Terminations for 3-core cables Medium Voltage 2013 CHE-3I(BS) Three-core indoor termination for all 3-core polymeric cables Type CHE-3I(BS) terminations are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (copper wire or tape). Cable accessories for screened cables according to British Standard Dimensions L = Length Ø S = Diameter of cable shed Characteristics • Flexible silicone stress control elements ensure reliable stress control under all operating conditions • Combination of slip-on and heat-shrink components • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Application • Indoor Note • Cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). Each unit contains materials for one set of three terminations. min. Ø over conductor L insulation after Type mm removal of outer semi-conducting layer mm U0/U (Um) 6/10 (12)kV - 6.35/11 (12)kV 25-95 350 12.6 CHE-3I(BS) 12kV 95-240 350 17.3 150-400 350 19.9 U0/U (Um) 8.7/15 (17.5)kV 25-50 400 12.6 CHE-3I(BS) 17kV 150-300 400 19.9 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 50-150 650 23.1 CHE-3I(BS) 36kV 150-400 650 27.3 Appropriate cable lugs must be ordered separately. 96 www.cellpack.com Number of sheds per phase ØS mm Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Tracking-resistant heat-shrink tubing • Silicone stress-control elements • Silicone sheds • Earthing kit • Sealing tape • Tracking resistant spreader cap • Assembly instructions Nominal cross section mm² Art.-No. 12kV 17.5kV 249328 249331 249332 25 - 95 95 - 240 150 - 400 25 - 50 150 - 300 2 2 85 115 36kV 249468 249469 50 - 150 249333 150 - 400 249334 Terminations for 3-core cables Medium Voltage 2013 CHE-3F(BS) Three-core outdoor termination for all 3-core polymeric cables Type CHE-3F(BS) terminations are suitable for all three-core plastic-insulated cables (PVC, PE, XLPE, EPR) with different types of semi-conducting layers (graphite-coated or strippable) and screening (copper wire or tape). L = Length Ø S = Diameter of cable shed Characteristics • Flexible silicone stress control elements ensure reliable stress control under all operating conditions • Combination of slip-on and heat-shrink components • Wide cross-section range • Quick, safe and easy assembly • Ready for immediate operation Type L mm Application • Outdoor Note • Cable lugs not included • 12 kV terminations must be used for 7.2 kV cables (Check minimum diameter over conductor insulation). min. Ø over conductor insulation after removal of outer semi-conducting layer mm (12)kV 12.6 17.3 19.9 U0/U (Um) 6/10 (12)kV - 6.35/11 25-95 1200 CHE-3F(BS) 12kV 95-240 1200 150-400 1200 U0/U (Um) 8.7/15 (17.5)kV 25-50 1200 CHE-3F(BS) 17kV 150-300 1200 U0/U (Um) 18/30 (36)kV - 19/33 (36)kV 50-150 1200 CHE-3F(BS) 36kV 150-400 1200 Number of ØS sheds per mm phase 1 1 1 85 85 85 12.6 19.9 2 2 85 85 23.1 27.3 3 3 85 115 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Tracking-resistant heat-shrink tubing • Silicone stress-control elements • Silicone sheds • Earthing kit • Sealing tape • Tracking resistant spreader cap • Assembly instructions Nominal cross section mm² Art.-No. 12kV 17.5kV 36kV 249191 249192 249193 25 - 95 95 - 240 150 - 400 25 - 50 150 - 300 249464 249466 50 - 150 249194 150 - 400 249195 Appropriate cable lugs must be ordered separately. www.cellpack.com 97 Cable accessories for screened cables according to British Standard Dimensions Accessories Medium Voltage 2013 AUF(BS) Armour continuity for three-core joints Armour continuity for armoured three-core polymeric cables in accordance with British Standard. Dimensions Cable accessories for screened cables according to British Standard L = Length Characteristics • Quick, safe and easy assembly • Superior electrical properties • High mechanical strength Type AUF 98 1100/53 1100/73 1100/87 1100/97 1100/107 www.cellpack.com Application • Earthing continuity and earth contactor • For cast resin, heat-shrink and slip-on cable accessories • Enables solder-free electrical connection of metal cable components (screen, armouring, metal sheath). L mm Internal-Ø mm 1100 1100 1100 1100 1100 53 73 87 97 107 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Hose clamp • Steel cage • Cloth tape • Backup-ring Nominal cross section mm² 7.2 kV 12 kV 17.5 kV 24 kV 150 150 - 300 95 120 - 300 70 95 - 240 150 - 300 50 70 - 150 150 - 300 Art.-No. 36 kV 95 120 - 185 150 - 300 240 - 400 195369 195380 195381 195382 304089 Accessories Medium Voltage 2013 EGA(BS) Earthing accessories for cables with tape screen and/or armouring for terminations Characteristics • Quick, safe and easy assembly • Superior electrical properties • High mechanical strength • Suitable for indoor and outdoor use Type EGA3BS (53) (68) (73) (87) (97) (107) Application • Earth connection and contactor • For cast resin, heat-shrink and slip-on cable accessories • Enables solder-free electrical connection of metal cable components (screen, armouring, metal sheath). Note • Incl. cable lug Internal-Ø mm Nominal cross section Copper braid mm² 53 68 73 87 97 107 25 25 25 35 35 35 Storage conditions/Shelf life • Unlimited shelf life Scope of delivery • Heat-shrink tube • Earthing wire • Earthing accessories • Pressure springs • Hose clamp • Backup-ring Nominal cross section mm² 7.2 kV 12 kV Cable accessories for screened cables according to British Standard Type EGA(BS) earthing kit for three-core polymeric cables in accordance with British Standard. 17.5 kV 24 kV Art.-No. 36 kV 150 95 70 50 150 - 240 120 - 240 95 - 185 70 - 150 50 240 - 300 185 - 300 150 - 240 120 - 185 70 - 95 185 - 300 185 - 300 120 - 185 185 - 300 400 185050 185051 185052 185053 185054 304092 www.cellpack.com 99 Accessories Medium Voltage 2013 CG Cable entry points for XLPE- and paper-insulated cables Cable entry point for junction boxes for transformers and substations. Dimensions Cable accessories for screened cables according to British Standard CG A CG B Scope of delivery • Heat-shrink tube • 1 Cable entry point • Assembly accessories • Assembly instructions Type CGA CGB 100 Ø mm² under armouring paper-insulated cable 30 - 46 47 - 75 www.cellpack.com under armouring of XLPE-cable 36 - 52 53 - 80 Art.-No. 183662 183661 Cable accessories for screened cables according to British Standard Medium Voltage 2013 Accessories www.cellpack.com 101 Customised solutions 102 www.cellpack.com Medium Voltage 2013 Medium Voltage 2013 Cable accessories for the industries Page Cable accessories for industries 104 www.cellpack.com 103 Cable accessories for shipyard-industrie Medium Voltage 2013 Cellpack‘s product portfolio also includes special solutions for the oil and gas, mining and shipbuilding industries as well as for offshore applications.These cable accessories are exposed to rain, salt, chemicals and extreme mechanical loads. Cable accessories for the shipbuilding industry The products especially designed for these applications comply with current international norms such as IEC and Cenelec, and with industry specific accreditation requirements. More specific information is available on request. 104 www.cellpack.com Cable accessories for shipyard-industrie Cable accessories for the shipbuilding industry Medium Voltage 2013 www.cellpack.com 105 106 www.cellpack.com Medium Voltage 2013 Medium Voltage 2013 We won‘t leave you in the lurch! Page Heat-shrink tubing 106 Compression cable lugs and Compression connectors complying with DIN 112 Screw cable lugs 119 Earthing components 120 Tapes 123 Tools 127 Chemical products 131 Accessories www.cellpack.com 107 Heat-shrink tubing Medium Voltage 2013 SRBB Heat-shrink tubing up to 36kV protection for busbar systems and reduction of minimum clearance Characteristics • Medium-walled • Stabilized against UV rays • Halogen-free • Tracking resistant • Non-corrosive • Resistant to bacteria and fungi Recommended application range round Ø mm Type 19-6 35-11 50-18 80-26 120-40 min. 6.5 13 18 28 45 max. 12 25 35 65 100 Colour(s) • red brown Material • Cross-linked polyolefin Recommended application range Width (B) + Height (H) rectangular mm min. 12 22 31 55 80 max. 18 36 60 95 150 Art.-No. 201942 201943 201944 201945 201946 Accessories SRBB Application • Allows for clearance reduction between busbars in medium voltage substations up to 36kV. • Corrosion protection L m Typ SRBB SRBB 108 19-6 35-11 50-18 80-26 120-40 19-6 35-11 50-18 80-26 120-40 www.cellpack.com 1 1 1 1 1 30 30 30 30 30 Internal-Ø before shrinkage mm 19 35 50 80 120 19 35 50 80 120 after shrinkage mm 6 11 18 26 40 6 11 18 26 40 Recovered Packing unit wall thickness Art.-No. piece x m mm 2.3 2.5 2.7 2.8 3 2.3 2.5 2.7 2.8 3 1x1 1x1 1x1 1x1 1x1 1 x 30 (Roll) 1 x 30 (Roll) 1 x 30 (Roll) 1 x 30 (Roll) 1 x 30 (Roll) 237858 237859 237860 237861 237862 201942 201943 201944 201945 201946 Heat-shrink tubing Medium Voltage 2013 Technical Data Physical properties Density Hardness Elongation at break Tensile strength at break Longitudinal shrinkage Shrink ratio Concentricity expanded Concentricity recovered Thermal properties Operating temperature range Shrinkage temperature Burning behaviour Flexibility at low temperatures Electrical properties Dielectric strength Volume resistivity Chemical properties Corrosion Water absorption Resistance to fungus and decay Value Test 1.22 g/cm³ 89 Shore A 500 % 16 N/mm² +5 % / -10 % 3:1 50 % 85 % IEC 60684-2 DIN 53 505 IEC 60684-2 IEC 60684-2 IEC 60684-2 IEC 60684-2 -40 °C up to 120 °C > 125 °C not self-extinguishing -40 °C IEC 60684-2 CP-PM-1004* IEC 60684-2 mode C IEC 60684-2 20 kV/mm 1012 Ω x cm IEC 60684-2 IEC 60684-2 none < 0.15 % Ra. 1 IEC 60684-2 IEC 60684-2 IEC 60684-2 IEC 60684-2 Busbar (round shaped) without isolation Ph/Ph and Ph/E with isolation Ph/Ph with isolation Ph/E Busbar (rectangular shaped) without isolation Ph/Ph and Ph/E with isolation Ph/Ph with isolation Ph/E 12kV mm 17.5kV mm 24kV mm 36kV mm 120 50 60 160 65 80 220 90 120 320 145 200 120 60 70 180 80 100 220 110 145 320 195 280 www.cellpack.com Accessories Minimum allowance between the busbars: 109 Heat-shrink tubing Medium Voltage 2013 SRAT Thick wall heat-shrink tubing Shrinkage ratio 3:1 Characteristics • Thick-walled • Stabilized against UV rays • Halogen-free • Non-corrosive • Infusible • Highly resistant to electrical breakdown • Tracking resistance in compliance with IEC 112 • High tensile strength • Resistant to cold flow (thermally stable) Accessories in 1m sections 19-6 29-9 38-12 48-15 SRAT 60-20 80-26 120-40 on rolls 19-6 29-9 38-12 SRAT 48-15 60-20 80-26 110 www.cellpack.com Internal-Ø Colour(s) • red brown Material • Cross-linked polyolefin • Free of lead and cadmium before shrinkage mm after shrinkage mm Recovered wall thickness mm 1 1 1 1 1 1 1 19 29 38 48 60 80 120 6 9 12 15 20 26 40 3 3 3.1 3.1 3.1 3.1 3.1 1x1 1x1 1x1 1x1 1x1 1x1 1x1 144888 144892 144898 132464 144921 144935 144943 30 30 30 30 30 30 19 29 38 48 60 80 6 9 12 15 20 26 3 3 3.1 3.1 3.1 3.1 1 x 30 (Roll) 1 x 30 (Roll) 1 x 30 (Roll) 1 x 30 (Roll) 1 x 30 (Roll) 1 x 30 (Roll) 144884 144882 144880 144878 144886 144876 L m Type Application • Insulation tube for conductors in terminations of 3.6 to 42 kV • Corrosion protection Packing unit Art.-No. piece x m Heat-shrink tubing Medium Voltage 2013 Physical properties Density Hardness Elongation at break Tensile strength at break Longitudinal shrinkage Shrink ratio Concentricity expanded Concentricity recovered Thermal properties Operating temperature range Shrinkage temperature Burning behaviour Flexibility at low temperatures Effect of thermal ageing (168h at 150°C) on elongation at break Electrical properties Dielectric strength Chemical properties Water absorption Resistance to fungus and decay Value Test 1.30 g/cm³ 50 Shore D 350 % 13 N/mm² +5% / -15% > 3:1 50 % 85 % DIN 53 479 DIN 53 505 DIN IEC 15C/590/CD DIN IEC 15C/590/CD DIN IEC 15C/590/CD DIN IEC 15C/590/CD -40 °C up to 120 °C > 125 °C not self-extinguishing -40 °C DIN IEC 15C/590/CD CP-PM-1004* DIN VDE 0304 DIN IEC 15C590/CD DIN IEC 15C/590/CD 300 % 16 kV/mm DIN VDE 0303 Part 2 < 0.15 % Ra. 1 DIN IEC 15C/590/CD Accessories Technical Data www.cellpack.com 111 Compression cable lugs and Compression connectors complying with DIN Medium Voltage 2013 DV-CU-V Cu compression connector complies with DIN 46267, without separator Strain relief connector (hexagonally compressed) for copper conductor, suitable for joints. Dimensions D L L = Length D = Centric bore hole Q = Cross section K = Die code no.~outer diameter Application • For RM/SM copper conductors complying with DIN VDE 0295 Accessories Type DV-CU-V 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 625 800 1000 L mm D mm Q mm² K Art.-No. 30 30 50 50 50 56 56 70 70 80 85 90 100 150 160 160 200 200 3.8 4.5 5.5 7.0 8.2 10.0 11.5 13.5 15.5 17.0 19.0 21.5 24.5 27.5 31.0 34.5 40.0 44.0 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 625 800 1000 5 6 8 10 12 14 16 18 20 22 25 28 32 38 42 44 52 58 125895 125950 125951 125952 125953 125954 125955 125956 125957 125958 125959 125960 125961 125962 125967 125963 125964 125965 To be used with suitable compression tool with DIN dies. Fixed price – no metal surcharge 112 www.cellpack.com Material • Copper tin-plated Compression cable lugs and Compression connectors complying with DIN Medium Voltage 2013 DVZ-CU-V-LD Cu compression connector complies with DIN 46267, with separator Strain relief connector (hexagonally compressed) with separator for copper conductor, suitable for joints. Dimensions D L L = Length D = Centric bore hole Q = Cross section K = Die code no.~outer diameter Type L m 6 30 10 30 16 50 25 50 35 50 50 56 DVZ-CU-V-LD 70 56 95 70 120 70 150 80 185 85 240 90 300 100 To be used with suitable compression tool with DIN dies. Fixed price – no metal surcharge Material • Copper tin-plated D mm Q mm² K Art.-No. 3.8 4.5 5.5 7.0 8.2 10.0 11.5 13.5 15.5 17.0 19.0 21.5 24.5 6 10 16 25 35 50 70 95 120 150 185 240 300 6 6 8 10 12 14 16 18 20 22 25 28 32 166374 125966 125897 125898 125899 125900 125901 125902 125903 125904 125905 125906 125907 www.cellpack.com 113 Accessories Application • Especially for transition sleeves and pot end joints • For RM/SM copper conductors complying with DIN VDE 0295 Compression cable lugs and Compression connectors complying with DIN Medium Voltage 2013 DV-AL Al Compression connector complies with DIN 46267, without separator Strain relief connector (hexagonally compressed) without separator for aluminium conductor, suitable for joints. Dimensions D L Application • RM/SM, SE and RE aluminium conductors complying with DIN VDE 0295 Note • *does not comply with DIN Standards Accessories Type DV-AL 16* 25 35 50 70 95 120 150 185 240 300 400 500 L mm D mm 55 70 85 85 105 105 105 125 125 145 145 210 210 5.8 6.8 8.0 9.8 11.2 12.6 14.7 16.3 18.3 21.0 23.3 26.0 29.0 To be used with suitable compression tool with DIN dies. Fixed price – no metal surcharge 114 www.cellpack.com RM/SM 16 25 35 50 70 95 120 150 185 240 300 400 500 Q mm² SE 25 35 50 70 95 120 150 185 240 300 L = Length D = Centric bore hole Q = Cross section RM = Multi-core stranded round SM = Multi-core stranded sector shaped SE = Sector shaped solid RE = Round solid K = Die code no.~outer diameter Material • Blank aluminium RE 16 25 35 50 K Art.-No. 12 12 14 16 18 22 22 25 28 32 34 38 44 195344 195345 195346 195347 125947 125948 125888 125889 125890 125891 125892 195348 195349 Compression cable lugs and Compression connectors complying with DIN Medium Voltage 2013 DVZ-AL-LD Al Compression connector complies with DIN 46267, with separator Strain relief connector (hexagonally compressed) with separator for aluminium conductor. Dimensions D L L = Length D = Centric bore hole Q = Cross section RM = Multi-core stranded round SM = Multi-core stranded sector shaped SE = Sector shaped solid K = Die code no.~outer diameter Application • RM/SM, SE and RE aluminium conductors complying with DIN VDE 0295 • Especially for transition sleeves and pot end joints DVZ-AL-LD 16 25 35 50 70 95 120 150 185 240 300 L mm D mm 75 75 90 90 110 110 110 130 130 150 155 5.4 6.8 8.0 9.8 11.2 13.2 14.7 16.3 18.3 21.0 23.3 Q mm² RM/SM 16 25 35 50 70 95 120 150 185 240 300 SE 25 35 50 70 95 120 150 185 240 300 K Art.-No. 12 12 14 16 18 22 22 25 28 32 34 198217 198219 198220 198221 198222 198223 198225 198226 198228 198230 198232 To be used with suitable compression tool with DIN dies. Fixed price – no metal surcharge www.cellpack.com 115 Accessories Type Material • Blank aluminium Compression cable lugs and Compression connectors complying with DIN Medium Voltage 2013 DK-CU-V Cu compression cable lug complies with DIN 46235 Cable lugs (hexagonally compressed) for copper conductors, suitable for indoor terminations. Dimensions D D1 B L L = Length B = Width D = Centric bore hole D1 = Flat hole diameter Q = Cross section K = Die code no.~outer diameter Application • Cable lugs for RM/SM copper conductors complying with DIN VDE 0295 Note • *does not comply with DIN Standards L mm Accessories Type B mm 6/6 24 8.5 10/8* 27 13.0 16/8 36 13.0 16/12* 36 18.0 25/10 38 17.0 25/12 38 19.0 35/10 42 19.0 35/12 42 21.0 50/10 52 22.0 50/12 52 24.0 70/10 55 24.0 70/12 55 24.0 95/12 65 28.0 95/16 65 32.0 DK-CU-V 120/12 70 32.0 120/16 70 32.0 150/12 78 34.0 150/16 78 34.0 185/12 82 37.0 185/16 82 37.0 240/12 92 42.0 240/16 92 42.0 300/14* 100 48.0 300/16 100 48.0 400/16 115 55.0 500/16* 125 60.0 625/16* 135 60.0 800/20 165 75.0 To be used with suitable compression tool with DIN dies. Fixed price – no metal surcharge 116 www.cellpack.com Material • Copper tin-plated Test standard • DIN 46235, Cable lugs for compression connections (lug mould for copper conductor) D mm D1 mm Q mm² K mm Art.-No. 3.8 4.5 5.5 5.5 7.0 7.0 8.2 8.2 10.0 10.0 11.5 11.5 13.5 13.5 15.5 15.5 17.0 17.0 19.0 19.0 21.5 21.5 24.5 24.5 27.5 31.0 34.5 40.0 6.4 8.4 8.4 13.0 10.5 13.0 10.5 13.0 10.5 13.0 10.5 13.0 13.0 17.0 13.0 17.0 13.0 17.0 13.0 17.0 13.0 17.0 15.0 17.0 17.0 17.0 17.0 21.0 6 10 16 16 25 25 35 35 50 50 70 70 95 95 120 120 150 150 185 185 240 240 300 300 400 500 625 800 5 6 8 8 10 10 12 12 14 14 16 16 18 18 20 20 22 22 25 25 28 28 32 32 38 42 44 52 126040 126044 126046 126048 126051 126052 126054 126055 126059 126060 126064 126065 126070 126072 126074 126077 126080 126082 126085 126087 126089 126091 126093 126094 126096 126098 126099 126102 Compression cable lugs and Compression connectors complying with DIN Medium Voltage 2013 DK-CU-V-LD Cu compression cable lug complies with DIN 46235, blocked Cable lugs Cu (hexagonal compression type) for copper conductors, designed for outdoor terminations. Dimensions D D1 B L L = Length B = Width D = Centric bore hole D1 = Flat hole diameter Q = Cross section K = Die code no.~outer diameter Type DK-CU-V-LD 16/12* 25/10 35/12 50/12 70/12 95/12 120/12 150/16 185/16 240/16 300/16 400/16 500/16* Material • Copper tin-plated Test standard • DIN 46235, Cable lugs for compression connections (lug mould for copper conductor) L mm B mm D mm D1 mm Q mm² K mm Art.-No. 36 38 42 52 55 65 70 78 82 92 100 115 125 18 17 21 24 24 28 32 34 37 42 46 54 60 5.5 7.0 8.2 10.0 11.5 13.5 15.5 17.0 19.0 21.5 24.5 27.5 31.0 13.0 10.5 13.0 13.0 13.0 13.0 13.0 17.0 17.0 17.0 17.0 17.0 17.0 16 25 35 50 70 95 120 150 185 240 300 400 500 8 10 12 14 16 18 20 22 25 28 32 38 42 159667 126134 159670 126135 148432 126136 195350 126137 195351 126138 176369 126105 126106 To be used with suitable compression tool with DIN dies. Fixed price – no metal surcharge www.cellpack.com 117 Accessories Application • Cable lugs for RM/SM copper conductors complying with DIN VDE 0295 Note • *does not comply with DIN Standards Compression cable lugs and Compression connectors complying with DIN Medium Voltage 2013 DK-AL-LD Al compression cable lug complies with DIN 46329, blocked Cable lugs (hexagonally compressed) for aluminium conductors, suitable for indoor and outdoor terminations. Dimensions D D1 B L Note • *does not comply with DIN Standards L = Length B = Width D = Centric bore hole D1 = Flat hole diameter Q = Cross section RM = Multi-core stranded round SM = Multi-core stranded sector shaped SE = Sector shaped solid RE = Round solid K = Die code no.~outer diameter Material • Blank aluminium Test standard • DIN 46329, Cable lugs for compression connections (circular mould for aluminium conductor) Accessories Type DK-AL-LD 16/10* 25/10 25/12 35/10 35/12 50/12 70/12 95/12 95/16* 120/12 120/16 150/12 150/16 185/12 185/16 240/16 300/16 400/20 500/20 L mm B mm D mm D1 mm 50 50 50 62 62 62 72 75 80 80 80 90 90 91 91 103 103 116 122 20 25 25 25 25 25 25 25 30 30 30 30 30 30 30 38 38 38 44 5.4 6.8 6.8 8.0 8.0 9.8 11.2 12.6 12.6 14.7 14.7 16.3 16.3 18.3 18.3 21.0 23.3 26.0 29.0 10.5 10.5 13.0 10.5 13.0 13.0 13.0 13.0 17.0 13.0 17.0 13.0 17.0 13.0 17.0 17.0 17.0 21.0 21.0 To be used with suitable compression tool with DIN dies. Fixed price – no metal surcharge 118 www.cellpack.com RM/SM 16 25 25 35 35 50 70 95 95 120 120 150 150 185 185 240 300 400 500 Q mm² RE 16 25 25 35 35 50 SE 25 35 35 50 50 70 95 120 120 150 150 185 185 240 240 300 K mm Art.-No. 12 12 12 14 14 16 18 22 22 22 22 25 25 28 28 32 34 38 44 194950 194949 194947 194945 194944 194943 194942 194941 194940 194939 194938 194937 194936 194935 194934 194933 194932 194930 194908 Screw cable lugs Medium Voltage 2013 CSK Screw cable lugs for Cu and AI blocked, aluminium tin-plated with shear bolts Screw cable lugs for RM, RE, SM, and SE aluminium and copper conductors, suitable for indoor and outdoor terminations. Dimensions Note • *CSK 240-400 : RM/RE cross section from 240 to 400 mm², SM/SE cross section from 240 to 300mm². • Cellpack counter bracket 255404 recommended for installation. L = Length L1 = Centric bore hole D = Outer diameter D1 = Flat hole diameter D2 = Bore hole diameter Q = Cross section S = Number of bolts Type CSK 6-50 16-95 50-150 95-240 240-400* L mm L1 mm D mm D1 mm D2 mm Q mm² S Art.-No. 65 65 80 110 135 30 30 35 60 75 22.0 22.0 26.0 33.0 40.0 13 13 13 13 17 9 13 16 20 26 6 - 50 16 - 95 50 - 150 95 - 240 240 - 400 1 1 1 2 2 255414 255415 255416 289968 255418 Other screw connectors available to order. Fixed price – no metal surcharge www.cellpack.com 119 Accessories Material • Aluminium, tin-plated Test standard • EN 61238-1 Earthing components Medium Voltage 2013 EGA Earthing accessories for cables with tape screen and/or armouring for terminations Type EGA earthing kits for terminations for single-core cables with copper braid or aluminium screen (Fig. 1), and for unarmoured three-core cables (Fig. 3). Kit components: 3 flat-rolled copper wires and 3 pressure springs Dimensions 1 Note • 1) Single core cables with copper tape or aluminium screens, non armoured. • 2) Single core cables with copper tape or aluminium screens, armoured: Please order extra pressure spring ZR1. • 3) Three core cables with copper tape or aluminium screens, non armoured. • 4) Three core cables with copper tape or aluminium screens, armoured: Please order extra pressure spring ZR2. Scope of delivery • Copper wire • Pressure spring 3 4 LS = external semi-conducting layer BS = Cu-Tape screen KM = Cable sheath RF = Type RF pressure spring ES = Cu-Earthing wire, flat tin-plated AR = Armouring ZR = Additional type RF pressure spring Accessories Characteristics • Quick, safe and easy assembly • Superior electrical properties • High mechanical strength • Suitable for indoor and outdoor use Application • Earthing continuity and earth contactor • For cast resin, heat-shrink and slip-on cable accessories • Enables solder-free electrical connection of metal cable components (screen, armouring, metal sheath). 2 Copper braid L Pressure mm spring Type EGA 16-2 16-3 25-3 25-4 35-4 35-5 500 500 500 500 500 500 RF 2 RF 3 RF 3 RF 4 RF 4 RF 5 Nominal ZR1 ZR2 Art.-No. Ø cross of hole 7.2 kV 12 kV 17.5 kV 24 kV 36 kV section mm mm² 8.5 16 150 120 70 50 RF 3 RF 5 143502 8.5 16 150 - 240 120 - 240 95 - 185 70 - 150 120 RF 4 RF 5 143503 10.5 25 150 - 500 120 - 500 95 - 300 70 - 300 70 - 240 RF 4 RF 6 143505 10.5 25 150 - 300 RF 5 RF 6 143506 10.5 35 500 - 1000 500 - 1000 400 - 800 300 - 800 185 - 500 RF 5 RF 6 143508 10.5 35 800 - 1000 800 - 1000 500 - 1000 RF 6 143509 For armoured cables, please order the pressure springs separately. 120 www.cellpack.com Nominal cross section mm² Earthing components Medium Voltage 2013 AUF Armour continuity for three-core joints Armour continuity kit for armoured three-core polymeric cables. Dimensions L = Length 1. Pressure spring 2. Copper wire 3. Pressure spring Type AUF 5 AUF 6 L mm Pressure spring 1200 1200 RF 5 RF 6 Application Scope of delivery • Earthing continuity and earth contactor • Copper wire • For cast resin, heat-shrink and slip-on • Pressure springs cable accessories • Enables solder-free electrical connection of metal cable components (screen, armouring, metal sheath). Nominal cross section mm² Copper braid 35 35 Art.-No. 7.2kV 12kV 17.5kV 24kV 36kV 300 400 240 300 - 400 240 300 - 400 150 185 - 300 70 95 - 300 195367 195368 For armoured cables, please order the pressure springs separately. www.cellpack.com 121 Accessories Characteristics • Quick, safe and easy assembly • Superior electrical properties • High mechanical strength Earthing components Medium Voltage 2013 RF Pressure spring Accessories Characteristics • Corrosion-resistant • Fatigue-proof • Guarantees consistent radial contact stress Application • For cast resin, heat-shrink and slip-on cable accessories • Enables solder-free electrical connection of metal cable components (screen, armouring, metal sheath) and earthing materials (copper grounding wire, cooper mesh sleeve) Colour(s) • brass Material • Special stainless steel Type Width mm External-Ø mm Cable-Ø mm Art.-No. RF 2 RF 3 RF 4 RF 5 RF 6 16 16 16 20 20 17.5 21.5 29.0 37.8 51.3 17 - 28 24 - 37 33 - 49 44 - 70 55 - 92 126296 126297 126298 126299 126300 Pressure springs are no current-carrying parts. 122 www.cellpack.com Tapes Medium Voltage 2013 No. 60, No. 62 High-voltage insulation tape self-amalgamating, pliable Type No. 60 No. 62 Application • Sealing of casting moulds • Padding of cable insulation • Conductor insulation for plastic-insulated cables up to 69 kV • Repairing and connection of various insulating and cable materials e.g. PE, XLPE, EPR, PVC, butyl, neoprene Colour(s) • black Material • EPR-Base Length m Width mm Thickness mm Art.-No. 10 10 5 10 19 19 38 38 0.5 0.75 0.75 0.75 125533 145908 125584 125589 Technical Data Elongation at break Tensile strength at break Dielectric constant Dissipation factor (50Hz) Dielectric strength Volume resistivity Temperature range Water absorption Value 900 % 3 N/mm² 2.8 0.0060 42 kV/mm 1012 Ω x cm -40 °C up to 100 °C 0.05 % www.cellpack.com 123 Accessories Characteristics • Easy application • Fuses to form a homogeneous, cavity-free compound within a short space of time. • Fully removable • Durable • Ozone-resistant • No electrolytic corrosion • Non tacky • Extremely ductile • Superior electrical properties • Excellent adherence to a wide range of substances • Superior physical properties • Weatherproof Tapes Medium Voltage 2013 No. 61 Conductive tape highly elastic, self-amalgamating Characteristics • Printed „CAUTION-CONDUCTING TAPE“ to eliminate danger of confusion • Fuses to form a homogeneous, cavity-free compound within a short space of time. • Durable • Ozone-resistant • No electrolytic corrosion • Self-fusing • Highly flexible • Superior physical properties Type Accessories No. 61 Technical Data Elongation at break Tensile strength at break Volume resistivity Temperature range 124 www.cellpack.com Application • Repairing of semi-conducting layer in medium voltage cables • Electrical field smoothing • For smoothing rough surfaces of connectors and cable lugs Colour(s) • black Material • EPR-Base Length m Width mm Thickness mm Art.-No. 9.1 4.6 19 19 0.76 0.76 125590 125604 Value 900 % 3 N/mm² 10 Ω x cm -40 °C up to 100 °C Tapes Medium Voltage 2013 No. 63 Copper braid tape tinned Type No. 63 25mm x 9.1m 25mm x 5m 60mm x 10m 60mm x 5m Application • Earthing continuity and earth contactor • Electrostatic shielding continuity • Semi-conducting continuity for connectors • Voltage grading continuity Colour(s) • silver Material • Braided tinned copper wires Length m Width mm Thickness mm Art.-No. 9.1 5.0 10.0 5.0 25 25 60 60 0.5 0.5 0.5 0.5 126303 126313 126316 126315 www.cellpack.com 125 Accessories Characteristics • Wrinkle-free application to all contours • High flexibility • Break-proof Tapes Medium Voltage 2013 No. 72 Repair tape Characteristics • Self-fusing • 100% waterproof • Superior electrical properties • High tensile strength Type Accessories No. 72 126 www.cellpack.com Application • Repairing of damaged sheaths of all plastic- and rubber-insulated cables and conductors Note • The use of a repair joint such as MZ is mandatory in case of damage extending beyond the cable sheath to the core insulation, screen or armour. Colour(s) • black Length m Width mm Thickness mm Art.-No. 10 25 0.75 125587 Tools Medium Voltage 2013 CPB Heat-shrink torch kit Application • Suitable for thick wall adhesive-lined heat-shrink tubing • Shrinking of heat-shrinkable polyolefin products using flame or hot air on pre-extruded compound Caution note • Warning: liquid gas is heavier than air. Adhere strictly to safety instructions provided with heat-shrink torch kit. Type CPB 5 (Set) * CPB 6 (Set) * Handle CPB 5/6 with piezo ignition Needle point burner Heat-shrink torch Hot-air torch Gas tube HD 4.4 R 3/8 LH x R 3/8 LH Anti-rupture device for tubing R 3/8” x 3/8” LH Pressure balance R 3/8“ x 3/8“ LH Pressure balance DIN/Kombi 21,8-14 LH x R 3/8 LH Refill connector, DIN Kombi Small gas bottle, refillable Scope of delivery • Wooden case with aluminium profile • Handle • Angulated hot-air torch • Angulated heat-shrink torch • Angulated needle point burner • 3 x R 3 pressure control device, 8“ li • Anti-rupture device for tubing • Gas tube • Open-end spanner SW 17/19 • Small gas bottle (0.4l content), incl. tube connection valve and suspension hook (CPB6) • Refill connector for a small gas bottle (CPB6) • 3 x DIN Kombi pressure control device (CPB5 8“ li) Length m Content ml 4 400 Art.-No. 146765 146766 146781 146782 146783 146784 146769 146770 146780 123960 146786 146785 Delivered in an aluminium side-faced wooden case. Components can also be ordered separately. www.cellpack.com 127 Accessories Characteristics • User-friendly rotating tube connector • Gas supply shuts off automatically if burner head not installed • Minimal risk of overheating • Flame extinguished immediately upon releasing push button • Continuously adjustable flame • Bayonet fitting facilitates substitution of burner head • Quick-starting piezo ignition Tools Medium Voltage 2013 Clamp tool Assembly guide for CSV screw connectors and CSK screw cable lugs Assembly guide for CSV screw connectors and CSK screw cable lug with a diameter 14-40mm. Scope of delivery • Clamp tool • Tool for diameter reduction Type Art.-No. CSV/CSK Accessories Clamp tool 128 www.cellpack.com 255404 Tools Medium Voltage 2013 CP-FLM20 Multi tool The CP-FLM20 is designed for the cutting and stripping of outer cable sheaths and conductor insulation, in addition to cold-strippable semi-conducting layers. Characteristics • Suitable for cables with a diameter of 15-50mm • For cold-strippable conducting layer. 0.3/0.4mm or 0.7/0.8mm according to thickness of material • Adjustable stop and limiting bar • Cut depth of the insulation and external sheath up to 10mm • Suitable for PVC/PE/XLPE insulation • Adjustable feed motion Application • Cutting and stripping of outer sheath • Controlled initial cutting of cold-strippable semi-conducting layer • Cutting and stripping of conductor insulation Scope of delivery • Allen key • Carrying case • CP-FLM20 Multi-tool Replacement cutter Multitool Art.-No. CP-FLM 20-S1 (for cable sheath) CP-FLM 20-S2 (for semiconductor-layer) CP-FLM 20 250355 250358 250351 www.cellpack.com 129 Accessories Type Tools Medium Voltage 2013 CP-P20 Peeling tool For removal of the co-extruded semi-conducting layer of medium voltage cables. Characteristics • Minimum strip length ca.30mm • Stripping depth adjustable from 0-1,2 mm in 0,1mm steps • Maintains high quality of stripped surface • Hard metal peeling knife • Operating range 10-50mm • Predefined rounded corners • Begin stripping at cable end • Automatic working feed Accessories Type Case assembly Peeling tool 130 CP-P 20 www.cellpack.com Application • Cutting and stripping of solid extruded semi-conducting layer. Length mm Width mm Height mm 200 300 90 Art.-No. 255897 250354 Chemical products Medium Voltage 2013 UNIVERSAL CLEANER 121 Detergent Type Universal Cleaner No.121 No.121 No.121 No.121 No.121 Application Colour(s) • Cleaning of semi-conducting layers • clear • Removal of semi-conductive residues (such as graphite) • Cleaning and degreasing of motors and electrical equipment • Cleaning of cables and conductors Note • Clean all parts thoroughly. Air dry or wipe with a cloth. Repeat operation as required. Always test a small area prior to cleaning plastics or finished surfaces. Content l Art.-No. 0.4 1 5 20 200 146404 124026 124027 146405 124029 Technical Data Density Vapour pressure (at 20°C) Flash point Ignition temperature Lower explosion limit (Vol.-%) Upper explosion limit Vol.-% Value 0.62 g/cm3 200 hPa -19 °C 260 °C 1.1 13.0 www.cellpack.com 131 Accessories Characteristics • For use with Neoprene, Polyethylene, EPR, XLPE, PVC; Butyl rubber and thermoplastic insulation • Protection against accidental discharge • Cleans and degreases without leaving residue. Non-conductive • Fast-acting, safe • No degradation Chemical products Medium Voltage 2013 ZINC SPRAY 171 Anti-corrosion spray Zinc spray No. 171 binds to steel and iron surfaces using an electrochemical application to build a flexible protection film. This gives the parts an active cathodic corrosion protection. Characteristics • Smooth, fine porous film • With hydrocarbon propellant (flammable) • Varnishable • Can be spot-welded • Dries quickly • Unmarked in compliance with ARB material regulations • No hazard rating, in compliance with VBF • Weatherproof • Electrically conductive • Frost-resistant Type Accessories Zinc spray No.171 Application • Long-lasting corrosion protection • Repairing of damaged zinc layer • Repairing of galvanised surfaces • Substitute for red lead primer • Primer for use in auto repair • Sealing of cavities • Cold galvanising • Oxidation protection • Rust prevention • Underground protection Colour(s) • grey Content l Art.-No. 0.4 124030 Zinc spray No. 171 is not approved according to the the food regulations and the construction material norms release 8/76 from the Institute for Construction Technology. Technical Data Density Degree of zinc purity 132 www.cellpack.com Value 0.95 g/cm3 99 % Chemical products Medium Voltage 2013 INDUSTRIE 3-36 Protective agent Type Industrie 3-36 Application • Dissolves rust • Corrosion protection • Protection of ferrous and non-ferrous metals during storage, processing, and transport • Release of tightly-sealed components • Moisture protection Farbe • green Content l Art.-No. 0.4 5 20 200 124014 124015 124016 124013 Technical Data Density Viscosity (cP) Flash point Dielectric strength Value 0.81 g/cm3 30/40 °C 105 °C 180 kV/mm www.cellpack.com 133 Accessories Characteristics • Forms a clear, transparent film • Lubricates and permeates Chemical products Medium Voltage 2013 Easy Glide Lubricant Easy-Glide simplifies and accelerates the feeding of cables through electrical installation conduits and cable ducts. Damage to the outer sheath is thus avoided. Characteristics • Available in light, practical 1050 ml plastic bottle or in handy 5 litre-buckets • Agreeable odour • Harmless ingredients • Biologically degradable • Non-corrosive • Superior lubricating properties • Non-adherent and does not stain • Does not cause skin irritation, easily washable • Nonflammable Application • Lubricant for feeding cables and wires through electrical installation conduits Drum Content l Art.-No. Plastic bottle Bucket 1.05 5 219647 246993 Type Accessories Easy Glide 1050ml 5000ml Easy-Glide can be used with bare hands. Apply evenly. Technical Data max. Heat resistance 134 www.cellpack.com Value 80 °C Chemical products Medium Voltage 2013 Easy Clean Hand wipes Easy Clean combines a powerful cleaning solution with a microfiber cloth developed especially for thorough wiping. The special Easy Clean cleaning solution dissolves grime but is gentle on hands. It removes heavy fat stains, grease, glue, oil, tar, asphalt, ink, wax, carbon stains, graphite, grass stains and resin, amongst others. Application • To remove ingrained dirt apply the darker side of the cloth. Leave to soak in, then rub. If the stain has not come out, leave to soak for longer • Remove most of the dirt using the darker textured side of the cloth, then polish with the soft side to achieve a completely clean residue-free finish • Skin may feel slightly sticky after use due to moisturising emulsion, as absorption time varies according to skin type Note • For external use only • Avoid contact with eyes • Keep dispenser away from heat sources • Keep out of reach of children Type Easy Clean Sales display in plastic dispenser Content Piece Art.-No. 40 72 265196 264705 www.cellpack.com 135 Accessories Characteristics • Heavy-duty one-step cleaning system • Easily removes even the toughest stains • Retains dirt without leaving traces • Quick-drying cleaning solution with moisturising effect • Biodegradable wipes • Antibacterial • Free from harmful substances • Non-toxic • Nonirritant • Contains moisturising substances 136 www.cellpack.com Medium Voltage 2013 Medium Voltage 2013 Ahead through groundbreaking technology Page Type index 138 Catalogue number index 140 Index www.cellpack.com 137 A Accessory Kit for Type CTS 630A Cellplux Plug-In Cable Connectors ...................................................54 Al compression cable lug ......................................118 Al Compression connector ............................114, 115 Anti-corrosion spray ..............................................132 Armour continuity for three-core joints ...........98, 121 Assembly guide for CSV screw connectors and CSK screw cable lugs ...................................................128 AUF ......................................................................121 AUF(BS) ..................................................................98 Index C Cable entry points for XLPE- and paper-insulated cables ...................................................................100 CAE-3F ...................................................................68 CAE-3I ....................................................................67 CAE-F .....................................................................44 CAE-I ......................................................................42 CAESK-F .................................................................43 CAESK-I ..................................................................41 CAM3-S ..................................................................62 CAM-S ....................................................................35 CG .......................................................................100 CGS 250A ..............................................................46 CHE-3F(A) ..............................................................64 CHE-3F(B) ...............................................................66 CHE-3F(BS) .............................................................97 CHE-3I(A) ...............................................................63 CHE-3I(B) ...............................................................65 CHE-3I(BS) .............................................................96 CHE-F .....................................................................39 CHE-F(BS) ...............................................................95 CHE-I ......................................................................37 CHE-I ......................................................................94 CHEP(3Pb)-3F .........................................................88 CHEP(3Pb)-3I .........................................................87 CHEP(H)-3F ............................................................83 CHEP(H)-3I .............................................................82 CHEP-3F .................................................................78 CHEP-3I ..................................................................77 CHM ......................................................................33 CHM(BS) ................................................................92 CHM3 ....................................................................61 CHM3(BS) ..............................................................93 CHMP(3Pb) 3 .........................................................85 CHMP(3Pb) 3-1 ......................................................84 CHMP(H) 3 .............................................................80 CHMP(H) 3-1 .........................................................79 CHMPP(3Pb)3 ........................................................86 CHMPP(H)3 ............................................................81 CHMPPR3 ...............................................................76 CHMPR 3 ................................................................75 CHMPR 3-1 ............................................................74 CHMPRSV 3-1 ........................................................73 CHMSV ..................................................................32 CHMSV3 ................................................................59 CHMSV3-1 .............................................................60 CIK .........................................................................53 CKM .......................................................................36 CKS 630A ...............................................................56 138 www.cellpack.com Medium Voltage 2013 Clamp tool ...........................................................128 Conductive tape ...................................................124 Connector element up to 24kV ..............................47 Copper braid tape ................................................125 Coupling connector 630A up to 24kV .....................56 CPB ......................................................................127 CPES .......................................................................57 CP-FLM20 ............................................................129 CP-P20 .................................................................130 CPS ........................................................................58 CSK ......................................................................119 CTKS 630A .............................................................50 CTKSA ....................................................................51 CTKSA ....................................................................52 CTS 630A ...............................................................49 Cu compression cable lug .............................116, 117 Cu compression connector ...........................112, 113 CVS 250A ...............................................................47 CWS 250A ..............................................................45 CWS 400A ..............................................................48 D Detergent .............................................................131 DK-AL-LD .............................................................118 DK-CU-V ...............................................................116 DK-CU-V-LD .........................................................117 DV-AL ...................................................................114 DV-CU-V ...............................................................112 DVZ-AL-LD ...........................................................115 DVZ-CU-V-LD .......................................................113 E Earthing accessories ........................................99, 120 Easy Clean ............................................................135 Easy Glide .............................................................134 EGA ......................................................................120 EGA(BS) ..................................................................99 Elbow plug-in cable connector ...............................48 Elbow plug-in cable connector with capacitive measurement .........................................................45 H Hand wipes ..........................................................135 Heat-shrink torch kit .............................................127 Heat-shrink tubing up to 36kV ..............................108 High-voltage insulation tape .................................123 I Indoor termination .....................................77, 82, 87 INDUSTRIE 3-36 ...................................................133 L Lubricant ..............................................................134 M M...MS6 .................................................................27 M...MSPB6 .............................................................72 Mounting Ring .......................................................55 Multi tool .............................................................129 Medium Voltage 2013 N Z No. 60, No. 62 .....................................................123 No. 61 ..................................................................124 No. 63 ..................................................................125 No. 72 ..................................................................126 ZINC SPRAY 171 ...................................................132 ZS-CTS ...................................................................54 O Outdoor termination ..................................78, 83, 88 P Peeling tool ..........................................................130 Plug- In Surge Arrester ......................................51, 52 Pressure spring .....................................................122 Protective agent ...................................................133 R Repair tape ...........................................................126 RF .........................................................................122 S Screw cable lugs for Cu and AI .............................119 SEEV .......................................................................28 SEEV-F ....................................................................29 Single-core indoor termination ...................37, 42, 94 Single-core indoor termination with screw cable lugs .....................................................41 Single-core outdoor termination .................39, 44, 95 Single-core outdoor termination with screw cable lugs .....................................................43 Single-core straight-through joint ...............33, 35, 92 Single-core straight-through joint with screw connector ...............................................32, 36 SMH3MS6 ..............................................................26 SRAT .....................................................................110 SRBB .....................................................................108 Straight plug-in cable connector with capacitive measurement .........................................46 Straight-through joint .................................76, 81, 86 Straight-through joint with screw connector ...........60 T Index Test and Earthing Kit ...............................................57 Test-Kit ...................................................................58 Thick wall heat-shrink tubing ................................110 Three-core indoor termination ........28, 63, 65, 67, 96 Three-core outdoor termination .....29, 64, 66, 68, 97 Three-core straight-through joint ..........26, 27, 61, 93 Three-core straight-through joint with heat-shrink outer protection ...................................62 Three-core straight-through joint with screw connector .....................................................59 Three-core transisition joint ....................................72 T-plug and socket connexion ..................................50 Transition joint 73, 74, 75, 79, 80, 84, 85 T-socket connexion .................................................49 U UNIVERSAL CLEANER 121 .....................................131 V Voltage-proof Insulating Cap ..................................53 www.cellpack.com 139 123... 126... 123960...........127 126040...........116 126044...........116 126046...........116 126048...........116 126051...........116 126052...........116 126054...........116 126055...........116 126059...........116 126060...........116 126064...........116 126065...........116 126070...........116 126072...........116 126074...........116 126077...........116 126080...........116 126082...........116 126085...........116 126087...........116 126089...........116 126091...........116 126093...........116 126094...........116 126096...........116 126098...........116 126099...........116 126102...........116 126105...........117 126106...........117 126134...........117 126135...........117 126136...........117 126137...........117 126138...........117 126296...........122 126297...........122 126298...........122 126299...........122 126300...........122 126303...........125 126313...........125 126315...........125 126316...........125 124... 124013...........133 124014...........133 124015...........133 124016...........133 124026...........131 124027...........131 124029...........131 124030...........132 124318.............27 124319.............27 124320.............27 124334.............72 124335.............72 Index 125... 125533...........123 125584...........123 125587...........126 125589...........123 125590...........124 125604...........124 125888...........114 125889...........114 125890...........114 125891...........114 125892...........114 125895...........112 125897...........113 125898...........113 125899...........113 125900...........113 125901...........113 125902...........113 125903...........113 125904...........113 125905...........113 125906...........113 125907...........113 125947...........114 125948...........114 125950...........112 125951...........112 125952...........112 125953...........112 125954...........112 125955...........112 125956...........112 125957...........112 125958...........112 125959...........112 125960...........112 125961...........112 125962...........112 125963...........112 125964...........112 125965...........112 125966...........113 125967...........112 140 www.cellpack.com 132... 132464...........110 143... 143502...........120 143503...........120 143505...........120 143506...........120 143508...........120 143509...........120 144... 144876...........110 144878...........110 144880...........110 144882...........110 144884...........110 144886...........110 144888...........110 144892...........110 144898...........110 144921...........110 144935...........110 144943...........110 145... 145458.............28 145461.............28 145464.............28 145630.............26 145633.............26 145635.............26 145908...........123 146... 146158.............63 146159.............63 146160.............63 146216.............63 146217.............63 146218.............63 146220.............64 146222.............64 146224.............64 146226.............64 146228.............63 146234.............64 146235.............64 146242.............64 146296.............64 146297.............63 146298.............64 146300.............63 146301.............63 146302.............63 146303.............64 146304.............64 146306.............64 146404...........131 146405...........131 146765...........127 146766...........127 146769...........127 146770...........127 146780...........127 146781...........127 146782...........127 146783...........127 146784...........127 146785...........127 146786...........127 148... 148152.............29 148153.............29 148432...........117 Medium Voltage 2013 159... 185... 159667...........117 159670...........117 166374...........113 185050.............99 185051.............99 185052.............99 185053.............99 185054.............99 171... 193... 171756.............64 171757.............64 171761.............63 171762.............63 171763.............63 171791.............28 193339.............34 193370.............34 193372.............40 193374.............40 193414.............38 193416.............38 173... 194... 173132.............65 173134.............65 194017.............38 194018.............38 194019.............38 194030.............38 194031.............38 194032.............38 194033.............38 194034.............38 194035.............38 194036.............38 194037.............38 194038.............38 194039.............38 194040.............38 194041.............38 194042.............38 194043.............38 194044.............38 194045.............38 194046.............38 194047.............38 194048.............38 194049.............40 194050.............40 194051.............40 194052.............40 194053.............40 194054.............40 194055.............40 194056.............40 194057.............40 194058.............40 194059.............40 194061.............40 194062.............40 194063.............40 194064.............40 194065.............40 194066.............40 194067.............40 194068.............40 194069.............40 194070.............40 194071.............40 194072.............34 194073.............34 166... 176... 176369...........117 180... 180522.............65 182... 182390.............29 182731.............65 182732.............65 182733.............65 182734.............65 182735.............66 182736.............66 182737.............66 182738.............66 183... 183661...........100 183662...........100 184... 184472.............66 184796.............65 184797.............65 184798.............65 184799.............65 184800.............65 184801.............65 184802.............65 184803.............65 184805.............66 184806.............66 184807.............66 184808.............66 184809.............66 184811.............66 184812.............66 184813.............66 184815.............66 184816.............66 Medium Voltage 2013 195... 195344...........114 195345...........114 195346...........114 195347...........114 195348...........114 195349...........114 195350...........117 195351...........117 195365.............63 195366.............64 195367...........121 195368...........121 195369.............98 195380.............98 195381.............98 195382.............98 197... 197515.............77 197516.............77 197517.............77 197531.............82 197532.............82 197533.............82 197534.............82 197535.............82 197536.............82 197537.............78 197538.............78 197539.............78 197543.............83 197544.............83 197545.............83 197546.............83 197547.............83 197548.............83 197555.............87 197556.............87 197557.............87 197558.............87 197559.............87 197560.............87 197567.............88 197568.............88 197569.............88 197570.............88 197571.............88 197572.............88 197603.............74 197604.............74 197606.............74 197607.............79 197608.............79 197609.............79 197610.............79 197614.............79 197616.............79 197617.............79 197618.............75 197619.............75 197620.............75 197621.............80 197622.............80 197623.............80 197624.............80 197625.............80 197626.............80 197627.............80 197628.............84 197629.............84 197630.............84 197631.............84 197632.............84 197633.............84 197634.............84 197635.............84 197636.............84 197637.............84 197638.............85 197639.............85 197640.............85 197641.............85 197642.............85 197643.............85 197644.............85 197645.............85 197646.............85 197647.............85 197658.............76 197659.............76 197660.............76 197661.............81 197662.............81 197663.............81 197664.............81 197665.............81 197666.............81 197667.............81 197668.............86 197669.............86 197670.............86 197671.............86 197672.............86 197673.............86 197674.............86 197675.............86 197676.............86 197677.............86 198... 198217...........115 198219...........115 198220...........115 198221...........115 198222...........115 198223...........115 198225...........115 198226...........115 198228...........115 198230...........115 198232...........115 198782.............84 198783.............85 198784.............86 199... 199151.............42 199152.............42 199154.............42 199155.............42 199157.............42 199158.............42 199159.............42 199160.............42 199162.............42 199163.............42 199164.............42 199165.............42 199166.............42 199167.............42 199168.............42 199170.............67 199171.............67 199173.............67 199174.............67 199175.............67 199177.............67 199178.............67 199179.............67 199180.............67 199181.............67 199182.............67 199184.............44 199185.............44 199186.............44 199187.............44 199189.............44 199190.............44 199191.............44 199192.............44 199194.............44 199195.............44 199196.............44 199197.............44 199198.............44 199199.............44 199201.............68 199202.............68 199204.............68 199205.............68 199206.............68 199208.............68 199209.............68 199210.............68 199211.............68 199212.............68 201... 201374.............62 201375.............62 201377.............62 201379.............62 201381.............62 201382.............62 201385.............35 201386.............35 201388.............35 201393.............35 201395.............35 201942...........108 201942...........108 201943...........108 201943...........108 201944...........108 201944...........108 201945...........108 201945...........108 201946...........108 201946...........108 219... 219647...........134 220... 220775.............49 224... 224826.............49 224853.............56 225... 225844.............47 237... 237858...........108 237859...........108 237860...........108 237861...........108 237862...........108 246... 246176.............48 246993...........134 247... 247102.............48 248... 248716.............93 248717.............93 248718.............93 248719.............93 248770.............93 249... 249191.............97 249192.............97 249193.............97 249194.............97 249195.............97 249328.............96 249331.............96 249332.............96 249333.............96 249334.............96 249464.............97 249466.............97 249468.............96 249469.............96 249471.............93 249474.............93 249476.............93 250... 250351...........129 www.cellpack.com 141 Index 194074.............34 194075.............34 194076.............34 194077.............34 194078.............34 194079.............34 194080.............34 194082.............34 194083.............34 194085.............34 194086.............34 194087.............34 194088.............34 194089.............34 194090.............34 194091.............34 194092.............34 194093.............34 194094.............34 194293.............61 194294.............61 194295.............61 194296.............61 194297.............61 194298.............61 194299.............61 194300.............61 194301.............61 194302.............61 194303.............61 194304.............61 194305.............61 194306.............61 194307.............61 194908...........118 194930...........118 194932...........118 194933...........118 194934...........118 194935...........118 194936...........118 194937...........118 194938...........118 194939...........118 194940...........118 194941...........118 194942...........118 194943...........118 194944...........118 194945...........118 194947...........118 194949...........118 194950...........118 250354...........130 250355...........129 250358...........129 250711.............49 250715.............49 250720.............48 250726.............48 251... 251713.............36 252... 252101.............36 253... 253843.............92 253844.............92 253845.............92 253847.............94 253848.............95 253849.............94 253850.............95 253911.............93 253917.............93 253929.............93 255... 255404...........128 255414...........119 255415...........119 255416...........119 255418...........119 255897...........130 256... 256010.............49 256328.............49 256838.............50 256839.............50 257... 257581.............50 257582.............50 257622.............54 Index 258... 258130.............32 258131.............32 258132.............32 258133.............32 258135.............32 258136.............32 258137.............32 258138.............32 258140.............32 258141.............32 258142.............32 258143.............32 258144.............32 258145.............32 258146.............32 259... 259101.............57 262... 262054.............51 262055.............51 262056.............51 262816.............51 264... 264366.............55 264705...........135 264769.............73 264988.............73 265... 265023.............53 265024.............53 265196...........135 265205.............73 265501.............73 289... 289894.............43 289897.............43 289898.............43 289899.............43 289900.............43 289901.............43 289902.............43 289903.............43 289904.............43 289905.............43 289906.............43 289907.............43 289908.............43 289909.............43 289910.............43 289911.............43 289912.............43 289945.............41 289947.............41 289948.............41 289949.............41 289950.............41 289951.............41 289952.............41 289953.............41 289954.............41 289955.............41 289956.............41 289957.............41 289958.............41 289959.............41 289960.............41 289961.............41 289962.............41 289963.............41 289968...........119 132... 293792.............45 142 www.cellpack.com 293797.............46 295... 295167.............45 295283.............46 297... 297104.............59 297260.............59 297310.............59 297311.............59 297348.............59 297349.............59 297350.............59 297351.............59 297352.............59 297353.............59 297358.............59 297360.............59 297361.............59 297362.............59 297433.............59 297441.............60 297442.............60 297443.............60 297444.............60 297449.............60 297460.............60 297461.............60 297462.............60 297463.............60 297464.............60 297465.............60 297466.............60 297467.............60 297468.............60 297469.............60 301... 301492.............52 302... 302227.............58 302732.............49 304... 304089.............98 304092.............99 Medium Voltage 2013 Index Medium Voltage 2013 www.cellpack.com 143 Cellpack AG Electrical Products Anglikerstrasse 99 5612 Villmergen Schweiz Tel. +41 56 618 12 34 Fax +41 56 618 12 45 [email protected] Cellpack Far East (PTE) LTD. 128 Joo Seng Road # 06 – 01 Singapore 368356 Tel. +65 6747 7024 Fax +65 6841 4554 [email protected] Cellpack GmbH Carl-Zeiss-Straße 20 79761 Waldshut-Tiengen Deutschland Tel. +49 7741 6007-0 Fax +49 7741 64989 [email protected] Behr Bircher Cellpack BBC Malaysia Sdn. Bhd. No. 8, Jalan TU 50 Taman Tasik Utama Ayer Keroh 75450 Melaka Malaysia Tel. + 60 6 251 95 30 Fax + 60 6 251 95 31 [email protected] www.cellpack.com.my Cellpack Benelux B.V. Keersluisweg 13 1332 EE Almere Buiten Nederland Tel. +31 36 549 03 36 Fax +31 36 532 74 99 [email protected] Behr Bircher Cellpack Ibérica, S.A. C/.Mas Pujol, nr. 47 – Nave 4 Pol. Ind. Sector V 08520 – Les Franqueses del Vàllès Barcelona – España Tel. +34 93 846 63 76 Fax +34 93 849 12 06 [email protected] Behr Bircher Cellpack BBC France s.à.r.l. 277, Boulevard des Technologies 54710 Ludres France Tel. +33 3 83 25 60 07 Fax +33 3 83 25 88 27 [email protected] Cellpack Polska Sp. z o.o. ul. Matuszewska 14, 03-876 Warszawa Polska Tel. +48 022 853 53 54 Fax +48 022 853 53 56 [email protected] www.cellpack.com