Bremas sezionatori GB.qxd

Transcription

Bremas sezionatori GB.qxd
Industrial
Automation
For over 40 years, BREMAS has been producing electro
mechanical products such us switches dedicated to applications
as food processing machinery, wood working machinery, welding
machines, lifts, water management, productions lines, power
tools and electricity supply systems and many others.
Wide experience has allowed BREMAS to become a specialist in
the industrial automation field and to be able to address specific
customer requests through customized solutions.
BREMAS is known for having achieved high quality standards
certified by the most important entities ( , e ).
The company is focused on the evolution of the industrial
automation market in order to be able to provide the most
complete and flexible solutions to every applications
requirement.
The parts and components of Bremas products are made of the
most advanced materials that can guarantee the compliance to
the most important quality standards and safety requirements.
BREMAS product range includes: cam switches, switch
disconnectors, power tools switches, control and signalling
units Ø22, foot switches.
BREMAS ERSCE S.p.A. I-20060 Liscate (MI) - Via Milano, 26 - Tel. +39.02.95651611 Fax. +39.02.95651639 - [email protected] www.bremas.it
SWITCHES IP20
Rear mounting
KNZ series
HANDLE DEVICE IP65
XNA series
Front mounting with screw
YNUT4
Grey/Black
YNGT4
Grey/Black
YNUY4
Yellow/Red
YNGY4
Yellow/Red
Plate 48x48
YNUT6
Grey/Black
YNGT6
Grey/Black
YNUY6
Yellow/Red
YNGY6
Yellow/Red
YNUT6C
Grey/Black
Front mounting in centre hole ø22 mm
XNA series
XNF series
XNA series
change-over
Base mounting
KNZ series
Plate 67x67
DIN rail mounting
YNUK6
Grey/Black
YNGK6
Grey/Black
YNUL6
Yellow/Red
YNGL6
Yellow/Red
YNUK6C
Grey/Black
YNUL6C
Yellow/Red
Plate with padlock 67x67
ACCESSORIES
Base fixing plate
2
Shaft extension for door interlock
device B-GNAPX / B-GNAMO
Terminals cover
KNZ 16-30-40
Terminals cover
XNA XNF 16-32
ENCLOSED VERSION IP65
ENCLOSED VERSION IP55
KNZ 16-30-40 series
XA 50-63-80-100 series
Plate with padlock (Emergency)
Grey plate and black knob
Plate with padlock (Emergency)
Change-over / double-ways XA 50-63 series
XNA 16-32 series
Plate with padlock (Emergency)
Grey plate and black knob
Grey plate and black knob
Grey plate and black knob
ACCESSORI
XNA-XNF
16-32A
Terminals cover
XNA 50-63-80-100A
Part no.
XC16CN
XC16AN
XC32CN
XC32AN
XC32GN
Type no.
1NO
1NC
1NO
1NC
PE
XNA
50-63-80-100A
Part no.
XC012AB
XC012CB
XC100GB
XC050PB
XC063PB
XC080PB
XC100PB
Type no.
1NO
1NC
PE
N
N
N
N
Auxiliary contacts and additional poles
3
OVERVIEW
KNZ, XNA switch-disconnectors designed for the switching and isolation of electrical machinery power supply lines.
Also available in XNF fused version for protection against over-currents.
XNA
Box terminals
Terminals protection degree IP20
Open hooded terminal connectors with dual slot screw
Silver alloy terminal plates with dual switching on positive opening
Ratings 16 up to 100 A
XNF with fuses
Ratings 16 up to 32 A
Auxiliary contact and additional
poles PE and N may be added.
KNZ
Ratings 16 up to 40 A
The IP65 handle device are available in versions:
Standard gray-black and yellow-red(emergency) in two dimensions
67x67 mm
48x48 mm
White plastic insert
used as manoeuvre
indicator and fixing
screw cover for the
knob to the shaft
Locking grey-black and yellow-red (emergency)
67x67 mm
When ordering, indicate the codes for the switch (bodies) and handle device, as the two products are handled separately
4
OVERVIEW
Available in three and four poles versions
Available with four different mounting systems
Rear mounting with screw
■ A complete range of accessories allow the
installation on the panel with 32 mm or
28 mm fixing distance screws.
Rear mounting Ø22 mm
■ Easy and fast installation. The connections
between the switch and the front trim plate
is allowed by a snap-on fixing system.
Base mounting
■ With a door locking device to attach the
finishing structure to the terminal in the On
position. The door locking function
guarantee the safety at the application
against accidental opening cabinet. The
switch can be equipped with two different
shaft extenction telescopic or modular.
+
+
Telescopic
Modular
Enclosed version
■ Version in IP65 insulating box. The container
has four PG hole inlets for the cable.
When ordering, indicate the codes for the switch (bodies) and handle device, as the two products are handled separately
5
STANDARD VERSIONS
Rear mounting with screw
KNZ - Switch-disconnectors 0-1
3 poles
Part no.
Type no.
VQ335300 KNZ16R3000
VQ344500 KNZ30R3000
VQ353600 KNZ40R3000
4 poles
Part no.
Type no.
VQ336100 KNZ16R4000
VQ345200 KNZ30R4000
VQ354400 KNZ40R4000
Rated operat. Rated operat.
current
power
AC21
AC23
16 A
30 A
40 A
11 Kw
15 Kw
22 Kw
Rated operat.
current
AC21
16 A
32 A
Rated operat.
power
AC23
15 Kw
22 Kw
XNA - Switch-disconnectors 0-1
3 poles
4 poles
Part no.
Type no.
VQ364300 XNA163R
VQ382500 XNA323R
Part no.
Type no.
VQ367600 XNA164R
VQ385800 XNA324R
Base mounting
KNZ - Switch-disconnectors 0-1 (*)
3 poles
Part no.
VQ329600
VQ338700
VQ347800
Type no.
KNZ16B3000
KNZ30B3000
KNZ40B3000
4 poles
Part no.
VQ330400
VQ339500
VQ348600
Type no.
KNZ16B4000
KNZ30B4000
KNZ40B4000
Rated operat.
current
AC21
16 A
30 A
40 A
Rated operat.
power
AC23
11 Kw
15 Kw
22 Kw
Rated operat.
current
AC21
16 A
32 A
50 A
63 A
80 A
100 A
Rated operat.
power
AC23
15 Kw
22 Kw
18.5 Kw
18.5 Kw
22 Kw
30 Kw
Rated operat.
current
AC21
16 A
32 A
Rated operat.
power
AC23
15 Kw
22 Kw
XNA - Switch-disconnectors 0-1 (*)
3 poles
Part no.
VQ362700
VQ380900
VQ355100
VQ356900
VQ357700
VQ358500
Type no.
XNA163B
XNA323B
XNA0503B
XNA0633B
XNA0803B
XNA1003B
4 poles
Part no.
Type no.
VQ365000 XNA164B
VQ383300 XNA324B
XNF - Switch-disconnectors 0-1 (*)
3 poles
Part no.
Type no.
VQ413800 XNF163B
VQ422900 XNF323B
• Dimensions, see page 15-16
• Circuit diagrams, see page 14
• Accessories, see page 12-13
• Technical data, see page 24-25
4 poles
Part no.
Type no.
VQ416100 XNF164B
VQ425200 XNF324B
(*) The switch can be installed without extenction shaft for maximum distance between the panel and the door
locking bracket device of 9 mm.
When ordering, indicate the codes for the switch (bodies) and handle device, as the two products are handled separately
6
STANDARD VERSIONS
Base mounting
XNA - Change-over switch 1-0-2
3 poles
Part no.
ZN880800
ZN881000
ZN881200
ZN881400
(*)
4 poles
Type no.
XNA0503BC
XNA0633BC
XNA0803BC
XNA1003BC
Part no.
ZN880900
ZN881100
ZN881300
ZN881500
Rated operat.
current
AC21
50 A
63 A
80 A
100 A
Type no.
XNA0504BC
XNA0634BC
XNA0804BC
XNA1004BC
Rated operat.
power
AC23
18.5 Kw
18.5 Kw
22 Kw
30 Kw
(*) The switch can be installed without extenction shaft for maximum distance between the panel and the door
locking bracket device of 9 mm.
• Dimensions, see page 15-16
• Circuit diagrams, see page 14
• Accessories, see page 12-13
• Technical data, see page 24-25
Handle device for rear mounting with screw and base mounting
KNZ-XNA-XNF series
IP65
Type no. Plate dim.
YNUT4
48 YNUT6
67 YNUT6C
67 IP65
Yellow plate with padlock in “0” position and red
knob (Emergency)
Grey plate and black knob
Part no.
VQ438500
VQ439300
ZN881600
KNZ-XNA-XNF series
Plate for
switch 0-1
switch 0-1
change-over switch
1-0-2
KNZ-XNA-XNF series
IP65
Part no.
Type no.
VQ436900 YNUL6
ZN881700 YNUL6C
Plate dim.
67 67 KNZ-XNA-XNF series
Plate for
switch 0-1
change-over switch
1-0-2
IP65
Yellow plate and red knob (Emergency)
Grey plate with padlock in “0” position and black
knob
Part no.
Type no.
VQ441900 YNUY4
VQ442700 YNUY6
Part no.
Type no. Plate dim.
VQ434400 YNUK6
67 ZN882200 YNUK6C
67 Plate dim.
48 67 Plate for
switch 0-1
switch 0-1
Plate for
switch 0-1
change-over switch
1-0-2
• Dimensions, see page 17
When ordering, indicate the codes for the switch (bodies) and handle device, as the two products are handled separately
7
STANDARD VERSIONS
Rear mounting Ø 22 mm
KNZ - Switch-disconnectors 0-1
3 poles
Part no.
VQ332000
VQ341100
VQ350200
4 poles
Type no.
KNZ16G3000
KNZ30G3000
KNZ40G3000
Part no.
VQ333800
VQ342900
VQ351000
Type no.
KNZ16G4000
KNZ30G4000
KNZ40G4000
Rated operat.
current
AC21
16 A
30 A
40 A
Rated operat.
power
AC23
11 Kw
15 Kw
22 Kw
Rated operat.
current
AC21
16 A
32 A
Rated operat.
power
AC23
15 Kw
22 Kw
XNA - Switch-disconnectors 0-1
3 poles
4 poles
Part no.
Type no.
VQ363500 XNA163G
VQ381700 XNA323G
Part no.
Type no.
VQ366800 XNA164G
VQ384100 XNA324G
• Dimensions, see page 15-16
• Circuit diagrams, see page 14
• Accessories, see page 12-13
• Technical data, see page 24-25
Handle device for rear mounting Ø22 mm
KNZ-XNA-XNF series
IP65
Plate dim.
48 67 KNZ-XNA-XNF series
IP65
Yellow plate and red knob (Emergency)
Grey plate and black knob
Part no.
Type no.
VQ430200 YNGT4
VQ431000 YNGT6
KNZ-XNA-XNF series
Plate for
switch 0-1
switch 0-1
IP65
Part no.
Type no.
VQ432800 YNGY4
VQ433600 YNGY6
Plate dim.
48 67 KNZ-XNA-XNF series
Plate for
switch 0-1
switch 0-1
IP65
Yellow plate with padlock in “0” position and red
knob (Emergency)
Grey plate with padlock in “0” position and black
knob
Part no.
Type no.
VQ429400 YNGL6
Part no.
Type no.
VQ428600 YNGK6
Plate dim.
67 Plate for
switch 0-1
Plate dim.
67 Plate for
switch 0-1
• Dimensions, see page 18
When ordering, indicate the codes for the switch (bodies) and handle device, as the two products are handled separately
8
STANDARD VERSIONS
Enclosed
KNZ series
BYP version(*)
IP65
Switch with grey plate and black knob
3 poles
Part no.
ZO061400
ZO062200
ZO063000
4 poles
Type no.
KNZ16B3000BYP
KNZ30B3000BYP
KNZ40B3000BYP
KNZ series
Part no.
ZO061800
ZO062600
ZO063400
Type no.
KNZ16B4000BYP
KNZ30B4000BYP
KNZ40B4000BYP
Rated operat.
current
AC21
16 A
30 A
40 A
BYN version(*)
Rated operat.
power
AC23
11 Kw
15 Kw
22 Kw
IP65
Main switch with padlock in ‘0’ position, grey plate and black knob
3 poles
Part no.
ZO061300
ZO062100
ZO062900
4 poles
Type no.
KNZ16B3000BYN
KNZ30B3000BYN
KNZ40B3000BYN
KNZ series
Part no.
ZO061700
ZO062500
ZO063300
Type no.
KNZ16B4000BYN
KNZ30B4000BYN
KNZ40B4000BYN
Rated operat.
current
AC21
16 A
30 A
40 A
BYL version(*)
Rated operat.
power
AC23
11 Kw
15 Kw
22 Kw
IP65
Emergency main switch with padlock in ‘0’ position, yellow plate and red knob
3 poles
Part no.
ZO061200
ZO062000
ZO062800
Type no.
KNZ16B3000BYL
KNZ30B3000BYL
KNZ40B3000BYL
4 poles
Part no.
ZO061600
ZO062400
ZO063200
Type no.
KNZ16B4000BYL
KNZ30B4000BYL
KNZ40B4000BYL
Rated operat.
current
AC21
16 A
30 A
40 A
Rated operat.
power
AC23
11 Kw
15 Kw
22 Kw
(*) An auxiliary contact and a neutral pole may be added. See page 12, accessories:
“Auxiliary contacts and additional poles for base mounting”
• Dimensions, see page 22
• Circuit diagrams, see page 14
• Technical data, see page 24-25
9
STANDARD VERSIONS
Enclosed
XNA series
BXP version(*)
IP65
Switch with grey plate and black knob
3 poles
4 poles
Part no.
Type no.
• VQ389000 XNA1630BXP
• VQ405400 XNA3230BXP
Part no.
Type no.
• VQ393200 XNA1640BXP
VQ409600 XNA3240BXP
Rated operat.
current
AC21
16 A
32 A
Rated operat.
power
AC23
15 Kw
22 Kw
(•) Available on request
XNA series
BXN version(*)
IP65
Main switch with padlock in ‘0’ position, grey plate and black knob
3 poles
4 poles
Part no.
Type no.
VQ388200 XNA1630BXN
VQ404700 XNA3230BXN
XNA series
Part no.
Type no.
VQ392400 XNA1640BXN
VQ408800 XNA3240BXN
Rated operat.
current
AC21
16 A
32 A
BXL version(*)
Rated operat.
power
AC23
15 Kw
22 Kw
IP65
Emergency main switch with padlock in ‘0’ position, yellow plate and red knob
3 poles
Part no.
Type no.
VQ387400 XNA1630BXL
VQ403900 XNA3230BXL
4 poles
Part no.
Type no.
VQ391600 XNA1640BXL
VQ407000 XNA3240BXL
(*) An auxiliary contact and a neutral pole may be added. See page 12, accessories:
“Auxiliary contacts and additional poles for base mounting”
• Dimensions, see page 22
• Circuit diagrams, see page 14
• Technical data, see page 24-25
10
Rated operat.
current
AC21
16 A
32 A
Rated operat.
power
AC23
15 Kw
22 Kw
STANDARD VERSIONS
Enclosed
XA series
BSP version(*)
IP55
Switch with grey plate and black knob
3 poles
4 poles
Part no.
Type no.
VC290500 XA0503BSP
• VD420700 XA0633BSP
VD422300 XA0803BSP
VD424900 XA1003BSP
(•) Available on request
XA series
Part no.
VC291300
• VD421500
VD423100
VD425600
Type no.
XA0504BSP
XA0634BSP
XA0804BSP
XA1004BSP
Rated operat.
current
AC21
50 A
63 A
80 A
100 A
BSN version(*)
Rated operat.
power
AC23
18.5 Kw
18.5 Kw
22 Kw
30 Kw
IP55
Main switch with padlock in ‘0’ position, grey plate and black knob
3 poles
Part no.
VD444700
VD446200
• VD448800
VD450400
4 poles
Type no.
XA0503BSN
XA0633BSN
XA0803BSN
XA1003BSN
Part no.
VD445400
VD447000
• VD449600
VD451200
Type no.
XA0504BSN
XA0634BSN
XA0804BSN
XA1004BSN
Rated operat.
current
AC21
50 A
63 A
80 A
100 A
Rated operat.
power
AC23
18.5 Kw
18.5 Kw
22 Kw
30 Kw
(•) Available on request
XA series
BSL version(*)
IP55
Emergency main switch with padlock in ‘0’ position, yellow plate and red knob
3 poles
Part no.
VD428000
VD430600
VD432200
VD434800
4 poles
Type no.
XA0503BSL
XA0633BSL
XA0803BSL
XA1003BSL
XA series
Part no.
VD429800
VD431400
VD433000
VD435500
Type no.
XA0504BSL
XA0634BSL
XA0804BSL
XA1004BSL
Rated operat.
current
AC21
50 A
63 A
80 A
100 A
BCSP/BDSP version
Rated operat.
power
AC23
18.5 Kw
18.5 Kw
22 Kw
30 Kw
IP55
Change-over switch or double-ways switch with grey plate and black knob
3 poles
Part no.
• VI809600
• VI808800
• VI807000
• VI806200
Type no.
XA0503BCSP
XA0633BCSP
XA0503BDSP
XA0633BDSP
Description
Change-over switch 3 poles 1-0-2
Change-over switch 3 poles 1-0-2
Double-ways switch 1-2
Double-ways switch 1-2
Rated operat.
current
AC21
50 A
63 A
50 A
63 A
Rated operat.
power
AC23
18.5 Kw
18.5 Kw
18.5 Kw
18.5 Kw
(•) Available on request
• Dimensions, see page 23
• Circuit diagrams, see page 14
• Technical data, see page 24-25
(*) An auxiliary contact and a neutral pole may be added. See page 12, accessories:
“Auxiliary contacts and additional poles for base mounting”
11
STANDARD VERSIONS
Auxiliary contacts and additional poles for rear mounting
XNA - XNF
Auxiliary contact 1NC o 1NO
PE
Accessories
Additional pole or auxiliary contact
for XNA – XNF series
Additional pole
Part no.
Additional pole
Auxiliary contact 1NC o 1NO
VC300200
VC301000
VC302800
VC303600
VC304400
Type no. Rating oper.
current
XC16AN 16 A
XC16CN 16 A
XC32AN 32 A
XC32CN 32 A
XC32GN 16-32 A
Descrip.
1NO
1NC
1NO
1NC
PE
PE
Max. 2 on each side
(XNF series only right side)
Auxiliary contact and additional poles for base mounting
Accessories
XNA - XNF
PE
Auxiliary contact 1NC o 1NO
Additional pole or auxiliary contact
for XNA – XNF series
Additional pole
XNA-XNF 16-32A
Part no.
XNA-XNF 16-32A
Additional pole
Auxiliary contact 1NC o 1NO
PE
Max. 2 on each side
(XNF series only right side)
VC301000
VC300200
VC303600
VC302800
VC304400
VD459500
VD460300
VD455300
VC298800
VD452000
VD453800
VD454600
Auxiliary contact 1NO
XNA 50-63-80-100A
Descrip.
1NO
1NC
1NO
1NC
PE
XNA 50-63-80-100A
Part no.
Auxiliary contact 1NC
Type no. Rating oper.
current
XC16CN 16 A
XC16AN 16 A
XC32CN 32 A
XC32AN 32 A
XC32GN 16-32 A
Type no. Rating oper.
currento
XC012AB 50-63-80-100 A
XC012CB 50-63-80-100 A
XC100GB 50-63-80-100 A
XC050PB 50 A
XC063PB 63 A
XC080PB 80 A
XC100PB 100 A
Descrip.
1NO
1NC
PE
N
N
N
N
PE
Auxiliary contact 1NO
Max. 1 for each side
• Dimensions, see page 17
• Technical data, see page 24-25
12
Auxiliary contact 1NC
Circuit diagrams of auxiliary
contact and additional poles
NO Auxiliary contact
NC Auxiliary contact
3
1
4
2
PE earth
N fourth advanced pole
PE
N
PE
N
STANDARD VERSIONS
Accessories
Telescopic shaft extension
L = mm
■ Used to adapt switches with base
mounting to different mounting depths
B-GNAPO
min
165
168
180
188
Lam=100 mm
max
min
215
218
230
238
215
218
230
238
max
min
265
268
280
288
265
268
280
288
max
min
315
318
330
338
565
568
580
588
max
615
618
630
638
B-GNAP1
Lam=150 mm
B-GNAP2
Lam=200 mm
5
B-GNAPO
B-GNAP1
B-GNAP2
B-GNAP4
Metal shaft
depth (Lam)
100 mm
150 mm
200 mm
500 mm
7,3
VQ447600
VQ448400
VQ449200
ZN869700
Type no.
Quota L per numero di elementi
L
Part no.
B-GNAP4
Lam=500 mm
Modular shaft extension
4 max
■ Used to adapt switches with base
mounting to different mounting depths
■ The pack contains 4 modules
L = mm
KNZ XNA-XNF XNA XNA 3/4PC BC
(16÷40) (16÷32) (50÷100) (50÷100)
Quota L per numero di elementi
3
1
2
L
Part no.
Type no.
VQ446800 B-GNAMO
KNZ XNA-XNF XNA XNA 3/4P BC
(16÷40) (16÷32) (50÷100) (50÷100)
1
min
101
103
115
123
max
min
111
113
125
133
126
128
140
148
max
min
136
138
150
158
151
153
165
173
max
min
161
163
175
183
176
178
190
198
max
186
188
200
208
2
Max. 4 modules
B-GNAMO
5
7,3
3
4
Base fixing plate
Part no.
Type no.
VC218600 B-KG6047
Terminal covers
Used to raise the level of protection for the connector
terminals
For series: KNZ (16÷40 A)
Part no.
Type no. Description
VC211100 B-G1280 3 or 4 poles
* the code includes the upper and lower protection
For series: XNA (50÷100 A)
Part no.
Type no.
Description
VD456100 B-G1305 3 poles
* the code includes the upper and lower protection
For series: XNA-XNF (16÷32 A)
Part no.
Type no.
Description
VC286300 B-G813
3 or 4 poles
* the code includes the upper and lower protection
For series: XNA (50÷100 A)
Part no.
Type no.
Description
VD457900 B-G1304 additional pole
* the code includes the upper and lower protection
13
CIRCUIT DIAGRAMS
Connection diagrams
Type
Diagram
L1 L2 L3
KNZ
XNA
Switchdisconnectors
3 poles
T1 T2 T3
Type
Diagram
L1 L2 L3 N
KNZ
XNA
Switchdisconnectors
4 poles
T1 T2 T3 N
Type
Diagram
XNA
(50-63
80-100 A)
Change-over
Double-ways
3 or 4 poles
1/L1
T1
14
T4
5/L3
3/L2
T2
T5
T3
T6
N
N
N
DIMENSIONS (mm)
Rear mounting
Type
Front view
Side view
55,5
53
9
KNZ...R
(16-30-40 A)
47
KNZ...G
(16-30-40 A)
70
53
9
67,5
XNA...R
(16-32 A)
XNA...G
(16-32 A)
Base mounting
Type
Front view
Side view
5
KZN...B
(16-30-40 A)
47
DIN 46277/3
55,5
7,3 DIN 4627/3
6,5 with B-KG6047
76
70
67,5
DIN 46277/3
28,5
XNA...B
(16-32 A)
67,5
4,2
7,3
5
64,5
78
15
DIMENSIONS (mm)
Base mounting
Type
Front view
Side view
90
60
5
L3
2
T1
4
T2
6
T3
5,2
68
3
L2
DIN 46277/3
1
L1
80
XNA...B
(50-63-80
100 A)
90
7,3
23,5
25
6,5
70
64,5
78
28,5
DIN 46277/3
4,2
7,3
99,5
XNF...B
(16 A)
72,5
5
70
64,5
78
28,5
DIN 46277/3
4,2
7,3
65
121,5
XNF...B
(32 A)
56,5
75,5
120.5 (3 Pole) - 164.5 (4 Pole)
XNA ... BC
(50-63-80
100 A)
16
5
DIMENSIONS (mm)
Handle devices
Type
Front view
Side view
Drilling template front mounting
Drilling template Base mounting
37
32
32
19
32
48
YNUT4
YNUY4
28 (*)
10
48
3,7
3,7
(*) in alternative to 32
67
19
38
36
38
36
67
YNUT6
YNUY6
YNUT6C
39
3,7
28 (*)
10
32
67
32
67
19
32
YNUK6
YNUL6
YNUK6C
YNUL6C
3,7
39
3,7
(*) in alternative to 32
Accessories
Type
40
15
Front view
XC100GB
XC050PB
XC063PB
XC080PB
XC100PB
Side view
22
68
52
XC32GN
XC012CB
XC012AB
XC16AN
XC32AN
XC16CN
XC32CN
Side view
48,5
Front view
67,5
Type
43,5
60
B-KG6047
M4
45
22
17
DIMENSIONS (mm)
Handle devices
Type
Front view
48
37
39
3,2 max
67
24,1
max
67
YNGT6
YNGY6
Drilling template
48
YNGT4
YNGY4
Side view
22,5
max
YNGK6
YNGL6
39
67
67
Assembly system body-handle device
Rear mounting Ø22 mm
18
DIMENSIONS (mm)
Base mounting – bodies/handle devices
Type
Front view
Side view
5
L
37÷39
55,5
A
A
48
67
YNUT4 - YNUY4
YNUT6 - YNUY6
DIN 46277/3
Bodies
KNZ...B
(16-30-40 A)
+
handle devices
YNUT4 - YNUY4
YNUT6 - YNUY6
Dimensions
7,3
1÷4
76
150
Min
76
Max
86
Dimensions
L
To adapt the switches with base mounting
to the various assembly depths,
see page 13
5
Bodies
KNZ...B
(16-30-40 A)
+
handle devices
YNUK6 - YNUL6
39
DIN 46277/3
67
L
76
Max
86
Dimensions
L
67
Min
7,3
1÷4
76
150
To adapt the switches with base mounting
to the various assembly depths,
see page 13
28,5
67,5
4,2
5
1÷4
78
150
64,5
A
48
67
YNUT4 - YNUY4
YNUT6 - YNUY6
DIN 46277/3
70
A
37÷39
L
7,3
Bodies
XNA...B
(16-32 A)
+
handle devices
YNUT4 - YNUY4
YNUT6 - YNUY6
Min
78
Max
88
Dimensions
L
To adapt the switches with base mounting
to the various assembly depths,
see page 13
67
Min
78
Max
88
Dimensions
L
67
Bodies
XNA...B
(16-32 A)
+
handle devices
YNUK6 - YNUL6
39
L
DIN 46277/3
7,3
5
78
1÷4
150
To adapt the switches with base mounting
to the various assembly depths,
see page 13
19
DIMENSIONS (mm)
Base mounting – Bodies/handle devices
Type
Front view
Side view
7,3
DIN 46277/3
39
Min
90
Max
100
L
5,2
Dimensions
1÷4
23,5
25
6,5
150
90
7,3
To adapt the switches with base mounting
to the various assembly depths,
see page 13
L
39
67
80
Min
90
Max
100
Dimensions
L
5,2
90
DIN 46277/3
67
60
Bodies
XNA...B
(50-63-80
100 A)
+
handle devices
YNUK6 - YNUL6
L
67
80
Bodies
XNA...B
(50-63-80
100 A)
+
handle devices
YNUT6 - YNUY6
90
67
60
Dimensions
1÷4
23,5
25
e
6,5
150
90
To adapt the switches with base mounting
to the various assembly depths,
see page 13
e
Bodies
XNA...BC
+
handle devices
YNUT6C
Min
97.5
Max 107.5
Dimensions
L
To adapt the switches with base mounting
to the various assembly depths,
see page 13
e
Bodies
XNA...BC
+
handle devices
YNUK6C
o
YNUL6C
e
Min
97.5
Max 107.5
Dimensions
L
To adapt the switches with base mounting
to the various assembly depths,
see page 13
20
DIMENSIONS (mm)
Base mounting – Bodies/Handle devices
Type
Front view
Side view
70
64,5
A
DIN 46277/3
28,5
4,2
5
78
Max
88
Dimensions
L
37÷39
L
A
48
67
78
Max
88
Dimensions
L
To adapt the switches with base mounting
to the various assembly depths,
see page 13
78
39
L
DIN 46277/3
7,3
Min
150
65
70
67
Min
YNUT4 - YNUY4
YNUT6 - YNUY6
5
67
L
To adapt the switches with base mounting
to the various assembly depths,
see page 13
24
56,5
63,5
75,5
28,5
Dimensions
150
DIN 46277/3
28,5
4,2
4,2
88
39
78
7,3
4,2
Max
DIN 46277/3
67
28,5
4,2
4,2
L
1÷4
4,2
78
To adapt the switches with base mounting
to the various assembly depths,
see page 13
1÷4
70
64,5
A
65
1÷4
150
Min
78
Max
88
Dimensions
L
24
Bodies
XNF...B
(32 A)
+
handle devices
YNUK6 - YNUL6
Min
150
78
7,3
58
72,5
Bodies
XNF...B
(32 A)
+
handle devices
YNUT4 - YNUY4
YNUT6 - YNUY6
YNUT4 - YNUY4
YNUT6 - YNUY6
5
70
67
A
48
67
37÷39
1÷4
58
72,5
Bodies
XNF...B
(16 A)
+
handle devices
YNUK6 - YNUL6
L
7,3
4,2
Bodies
XNF...B
(16 A)
+
handle devices
YNUT4 - YNUY4
YNUT6 - YNUY6
Dimensions
56,5
63,5
75,5
5
78
To adapt the switches with base mounting
to the various assembly depths,
see page 13
21
DIMENSIONS (mm)
Enclosed
Type
Front view
Side view
78
37-39
80
98
KNZ
BYP
(16-32-40 A)
125
4.5
110
Drilling template
N°4 ø Pg 16 - M20
78
80
98
125
KNZ
BYL/BYN
(16-32-40 A)
37-39
4.5
110
N°4 ø Pg 16 - M20
140
97
115
142
142
165
XNA
Type
BXP
(16-32 A)
115
6,5
60
140
97
XNA
Type
BXL/BXN
(16-32 A)
22
165
6,5
60
DIMENSIONS (mm)
Enclosed
Type
Front view
Side view
150
100
Drilling template
30
N° 4 Ø Pg 29 - M40
150
185
N° 8 Ø Pg 21 - M25
220
6,5
XA
Type
BSP/BSG
(50-63-80
100 A)
115
100
30
N° 4 Ø Pg 29 - M40
190
185
N° 4 Ø Pg 21 - M25
220
6,5
XA
Type
BSL/BSN
(50-63-80
100 A)
115
125
30
N° 4 Ø Pg 29 - M40
205,4
6,5
2
N° 8 Ø Pg 21 - M25
1
240
XA
Type
BCSP/BDSP
(50-63 A)
155,4
23
TECHNICAL DATA
Conformity to standards IEC 947-1 EN 60947-1
Rated insulation voltage
Rated operating voltage
Rated impulse withstand voltage
Rated thermal current
open
enclosed
Rated operation frequency
Power dissipation for each pole
Rated operating current Ie in category
AC-21A Switching resistive loads with light overloads
AC-22A Switching mixed resistive and inductive loads with light overloads
Rated operating power
AC-23A Periodic switching of motors and interruption while running
AC-3
Starting of cage motors and interruption while running
Ui
Ue
Uimp
Ith
Ithe
V
V
kW
A
A
Hz
W
KNZ16
690
690
6
25
25
50
1
KNZ30
690
690
6
32
32
50
1.1
KNZ40
690
690
6
40
40
50
1.6
3 phases – 3 poles + neutral
3 phases – 3 poles + neutral
690V
690V
A
A
20
16
30
32
40
32
3 phases – 3 poles
230V
400V
500V
690V
230V
400V
500V
690V
230V
400V
A/kW
A/kW
A/kW
A/kW
A/kW
A/kW
A/kW
A/kW
A
A
22/5.5
18/8
14/9
14/11
16/4
18/7.5
12/7.5
10/9
184
160
24/7.5
20/12
16/11
16/15
17/6
15/9.5
14/9.5
12/11.5
248
264
31/10
33/18.5
32/22
23/22
27/9
27/17
28/19
24/22
Icw
Icm
A
A
kA
A
600
1500
10
16
600
1500
10
16
800
2000
10
32
Cycles 106
Nm
2
B6
1.5-10
1.5-16
M4
1.4
2
B6
1.5-10
1.5-16
M4
1.4
2
B6
1.5-10
1.5-16
M4
1.4
600Vac
A
25
30
30
120V
240V
120V
240V
480V
600V
HP/FLA
HP/FLA
HP/FLA
HP/FLA
HP/FLA
HP/FLA
-/-/2/5/7.5/7.5/-
2/24
3/17
3/19.2
7.5/12
10/14
10/11
3/5/5/7.5/22
10/14
10/11
AWG
AWG
lb.in.
16-8
16-6
12
16-8
16-6
12
16-8
16-6
12
3 phases – 3 poles
Rated breaking capacity in category AC-23A (Cosϕ 0,45)
Short-circuit safety
Rated short time with stand current (1s)
Rated short-circuit make capacity
Rated conditional short-circuit current
With fuses class gG
Mechanical data
Mechanical life (120 cycles/hour)
Connection according to IEC 947-1 and EN 60947-1
Connecting capacity
stranded wires plus connector
solid wires
Connection terminal screw dimensions
Screw tightening torque
500V
Min-Max
Min-Max
Technical data UL/CSA
General Use current
Rated operating power
1 phase - 2 poles
3 phases - 3 poles
Mechanical data
Connecting capacity
stranded wires plus connector
solid wires
Screw tightening torque
mm2
mm2
Protection degree according to IEC 529 EN 60529
Body
Handle devices
Normal service conditions
Ambient temperature operative
storage
Weather resistance, according to IEC 68 part:
24
IP20
IP65
°C
°C
constant hot-damp climate
cyclic hot-damp climate
-25 +55
-30 +70
2-8
2-30
TECHNICAL DATA
Conformity to standards IEC 947-3 EN 60947-3
Rated insulation voltage
Rated operating voltage
Rated impulse withstand voltage
Rated thermal current
open
enclosed
Rated operation frequency
Power dissipation for each pole
Rated operating current Ie in category
AC-21A Switching resistive loads with light overloads
3 phases – 3 poles + neutral
AC-22A Switching mixed resistive and inductive loads with light overload 3 phases – 3 poles + neutral
Rated operating power
AC-23A Periodic switching of motors and interruption while running 3 phases – 3 poles
AC-3 Starting of cage motors and interruption while running
3 phases – 3 poles
Rated breaking capacity in category AC-23A (Cosϕ 0,45)
Short-circuit safety
Rated short time with stand current (1s)
Rated short-circuit make capacity
Rated conditional short-circuit current
With fuses class gG
Mechanical data
Mechanical life (120 cycles/hour)
Connection according to IEC 947-1 and EN 60947-1
Connecting capacity
stranded wires plus connector
solid wires
Connection terminal screw dimensions
Screw tightening torque
Technical data UL/CSA
General Use current
Rated operating power
1 phase - 2 poles
3 phases - 3 poles
Mechanical data
Connecting capacity
Ui
Ue
Uimp
Ith
Ithe
V
V
kW
A
A
Hz
W
XNA16
690
690
6
25
16
50
0.9
690V
690V
A
A
20
16
40
32
230V
400V
500V
690V
230V
400V
500V
690V
230V
400V
A/kW
A/kW
A/kW
A/kW
A/kW
A/kW
A/kW
A/kW
A
A
7.5
13
13
15
6
10
10
12
184
192
33/10
33/18.5
32/18.5
28/22
27/15
27/15
27/15
23/18.5
256
264
Icw
Icm
A
A
kA
A
400
1500
10
16
800
2000
10
32
1500
2000
15
63
1500
2000
15
63
1500
2500
15
80
Cycles 106
Nm
2
B6
1.5-10
1.5-16
M4
1.4
2
B6
1.5-10
1.5-16
M4
1.4
0.1
B9
6-35
10-50
M5
2.8
0.1
B9
6-35
10-50
M5
2.8
600Vac
A
20
40
80
120V
240V
120V
240V
480V
600V
HP/FLA
HP/FLA
HP/FLA
HP/FLA
HP/FLA
HP/FLA
1.5
2
2
5
10
10
3/34
5/28
5/30.5
10/28
15/27
15/27
3/34
5/28
10/32 (*)
20/54
25/34
30/32
AWG
AWG
lb.in.
16-8
16-6
12
16-8
16-6
12
500V
Min-Max
Min-Max
stranded wires plus connector
solid wires
Screw tightening torque
mm2
mm2
XNA32 XNA050 XNA063 XNA080 XNA100 XNF16
690
690
690
690
690
690
690
690
690
690
690
690
6
6
6
6
6
6
40
50
63
80
100
16
32
50
63
80
80
16
50
50
50
50
50
50
1.6
1.8 (**)
50
50
Weather resistance, according to IEC 68 part:
100
100
16
16
32
32
24/7.5
24/13
16/13
16/15
19/16
18/10
14/10
13/2
192
240
33/10
33/18.5
32/18.5
23/22
28/9
27/15
27/15
23/18.5
256
330
1500
2500
15
100
400
800
10
16
10
32
0.1
B9
6-35
10-50
M5
2.8
0.1
B9
6-35
10-50
M5
2.8
2
B6
1.5-10
1.5-16
M4
1.4
2
B6
1.5-10
1.5-16
M4
1.4
100
100
10-1
8-1
24
10-1
8-1
24
5/56
5/56
7.5/40 10/40
15/48 (*) 20/62 (*)
20/54
25/68
40/52
50/65
50/52
50/52
10-1
8-1
24
10-1
8-1
24
IP20
IP65
operative
storage
constant hot-damp climate
cyclic hot-damp climate
°C
°C
Conformity to standards IEC 947-3-5 EN 60947-3-5
Auxiliary contacts
Rated insulation voltage
Rated thermal current
open
AC-21A Switching resistive loads with light overloads
AC-15 Electromagnetic loads in AC
80
80
40/11 47/15 58/18.5 70/22
40/22 47/25 54/30
63/35
32/22 43/30 54/37
65/45
19/18.5 19/18.5 24/22
31/30
35/11 35/11 17/45 58/18.5
18.5/33 33/18.5 43/22
54/30
28/18.5 32/22 43/30
53/37
16/15 16/15 19/10.5 23/22
320
376
464
560
320
376
432
504
Protection degree according to IEC 529 EN 60529
Body
Handle devices
Normal service conditions
Ambient temperature
63
63
XNF32
690
690
6
32
32
50
3.5 (**)
Ui
Ith
690V
230V
Type no. XC16AN XC32AN
Type no. XC16CN XC32CN
V
690
690
A
20
40
A
6
6
A
20
40
-25 +55
-30 +70
2-8
2-30
XC012AB
XC012CB
690
12
6
XC16AN XC32AN
XC16CN XC32CN
690
690
20
40
6
6
20
40
(**) for each single fuse
(*) test at 200V
25
APPROVALS
XNF
SERIES
XNA SERIES
KNZ SERIES
SERIES
26
i
C
®
US
KNZ16
✔
✔
KNZ30
✔
✔
KNZ40
✔
✔
✔
XNA016
✔
✔
✔
XNA032
✔
✔
✔
XNA050
✔
✔
✔
✔
XNA063
✔
✔
✔
✔
XNA080
✔
✔
✔
✔
XNA100
✔
✔
✔
✔
XNF16
✔
✔
XNF32
✔
✔
TECHNICAL INFORMATION - STANDARDS
BREMAS switchgears and controlgears are designed, manufactured and
tested in accordance with the requirements laid down in the most
important national and international specifications and standards.
In most countries, the use of electrical devices is permitted if the
manufacturer, upon his own responsibility, guarantees the conformity to the
requirements. In other countries, the law lays down compulsory approval
procedures.
For better understanding of the subject, the information set out below deals
with REQUIREMENT, CONFORMITY, APPROVAL.
REQUIREMENTS
This refers to the definitions contained in a standard relating to normal
operating conditions, performance requirements, test procedures, etc.
Requirements can be subdivided into:
QUALITY MARK
This is a special form of approval adopted for equipment for household use.
The best known Authorities are:
IMQ
Istituto Marchio di Qualità, Italy
KEMA-KEUR Keuring van Elektrotechnische Materialen,
The Netherlands
MARINE CLASSIFICATION
This is a special form of approval adopted for equipment installed on board
of ships.
The best known Authorities are:
RINA
Registro Italiano Navale, Italy
LROS
Lloyd’s Register of Shipping, Great Britain
BV
Bureau Veritas, France
Internationals requirements
These are the requirements issued by the following Authorities:
IEC
International Electrotechnical Commission
This international commission, with members from all the
major industrialised countries, issues recommendations that
are taken up as the basis of the single national standards.
CENELEC Comité Européen de Normalisation Electrotechnique
This committee issues the EN standards for the European
countries.
National Requirements
For example, the requirements issued by the following Authorities:
CEI
Comitato Elettrotecnico Italiano, Italy
VDE
Verband Deutscher Elektrotechniker, Germany
NF
Normes Françaises, France
CSA
Canadian Standards Association, Canada
UL
Underwriter’s Laboratories, United States of America
CONFORMITY
Conformity to a standard consists of a declaration made by the
manufacturer under his own responsibility to the effect that a specific
product comply with all the requirements of the relevant standard.
Recently, the CE Mark has been introduced, for which the manufacturer
declares that the products comply with the EEC applicable Directives. For
the electrical material the EEC applicable Directives are: LOW VOLTAGE
Directive (72/23/EEC, modified to 93/68/EEC) for the safety of electric
products and E.M.C. Directive (89/339/EEC, modified to 92/31/EEC and to
93/68/EEC) and Electromagnetic Compatibility.
APPROVAL
IIn some countries, approval of electric materials is compulsory by law.
This consists of a certificate of conformity with the requirements issued not
by the manufacturer, but by an independent Testing Laboratory legally
recognized. Each approved item has to carry the mark of approval, such as
CSA or UL. For this last, two different levels of acceptance are required:
RECOGNIZED = The device should be marked with the letters UR only, and
can be used in electrical equipment only by qualified personnel who are
fully aware of the limits of use of the product.
The sale of this equipment for general use is not permitted.
LISTED = The device should be marked with the letters UL alongside the
mark of approval and can be fitted in electrical appliances or sold loose, as
it complies with all the requirements in the relevant standard.
27
TECHNICAL INFORMATION - DEFINITIONS
Utilization category
The standards define a certain number of categories with regard to the
normal applications of contactors.
Each category defines the current and the voltage values (expressed as
multiples of the rated values) that corresponds to the connection and the
switching of the load.
Operating cycle
A succession of operations from one position to another and back to the
first position through all other positions, if any.
Main circuit
All the conductive parts of a switching device included in the circuit which
it is designed to close or open
Control circuit
All the conductive parts (other than the main circuit) of a switching device
which are included in a circuit used for the closing operation or opening
operation, or both, of the device.
Auxiliary circuit
All the conductive parts of a switching device which are intended to be
included in a circuit other than the main circuit and the control circuits of
the device.
Rated operational current Ie
Current which takes into account the rated voltage, the rated frequency, the
rated duty, the utilization category.
Rated thermal current Ith
The maximum current that a switching device can carry on eight-hour duty,
without the temperature rise of its several parts exceeding the limits
specified.
Short-time withstand current
The current that a switching device can withstand in the closed position
during a specified short time, under prescribed conditions of use and
behaviour.
Time constant or Power factor
The ratio between the inductance and resistance, that is L/R = mH/Ω=ms
Clearance
The distance between two conductive parts, along a string stretched the
shortest way between these conductive parts
Creepage distance
The shortest distance along the surface of an insulating material between
two conductive parts.
Electrical durability
It is defined as the number of on-load operating cycles which will be
attained or exceeded by 90% of all devices tested without repair or
replacement of any part.
Mechanical durability
It is defined as the number of no-load operating cycles which will be
attained or exceeded by 90% of all devices tested without repair or
replacement of any part.
Pole impedance
This is the complex resistance of a pole at rated current.
Breaking or making capacity
A value of prospective breaking or making current that a switching device
is capable of breaking or making at the stated voltage under prescribed
condition of use and behaviour.
28
Intermittent duty
A duty with on-load periods, in which the main contacts of the equipment
remain closed, having a definite relation to off-load periods, both periods
being short to allow the equipment to reach thermal equilibrium.
Intermittence ratio (I.R.) or operation factor (m)
It represents the ratio between “t” duration of the current flow and “T” total
operating cycle time, that is I.R. or m=t/T.
Often this ratio is expressed as a percentage.
For total operating cycle time, it is understood the time elapsing between
the beginning of two consecutive passings of current.
Opening time
The interval of time between the specified instant of initiation of the
opening operation and the instant when the arcing contacts have separated
in all poles.
Closing time
The interval of time between the initiation of the closing operation and the
instant when the contacts touch in all poles.
Air ambient temperature
It is the temperature, determined under prescribed conditions, of the air
surrounding the complete switching device.
For devices installed inside an enclosure, it is the temperature of the air
outside the enclosure.
Rated operational voltage Ue
A value of voltage which, combined with a rated operational current,
determines the application of the equipment and to which the elevant tests
and the utilization categories are referred.
Rated insulation voltage Ui
The value of voltage to which dielectric tests and creepage distances are
referred.
TECHNICAL INFORMATION - UTILIZATION CATEGORIES
Utilization with alternating current
Utilization with direct current
Power equipment , switchgear and controlgear according
to EN 60947-4 and IEC 947-4
(contactors, equipment for starting of motors)
Power equipment, switchgear and controlgear according
to EN 60947-4 and IEC 947-4
(contactors, equipment for starting of motors)
AC1
Connection or disconnection of non-inductive or slightly inductive
loads (e.g. resistance furnaces).
This equipment should have a cos no less than 0,95
DC1
AC2
Starting, counter-current braking and switching off of slip-ring
motors.
The contactor makes and breaks the starting current, which can
reach 1,5 ÷ 3 times the rated current of the motor.
DC3
AC3
Starting and switching off of squirrel-cage motors during running.
The contactor makes the starting current, which can reach 4 ÷ 8
times the rated current of the motor, and breaks the rated current
absorbed by the motor.
The switching conditions are easy, as the voltage at the motor
terminals is approximately 20 ÷ 30% of the supply voltage.
Starting, plugging and inching of squirrel-cage motors.
The contactor makes and breaks the starting current, which can
reach 4 ÷ 88 times the rated current of the motor.
The switching conditions are severe, as the voltage at the motor
terminals can be equal to that of the supply voltage.
Switching of electric discharge lamp controls.
Switching of incandescent lamps.
The peaks of current at the connection of the lighting circuits and
the power factor are function of the type of lamp, the wiring system
and the presence or not of the compensation.
Switching of transformers.
High peaks of current characterize the commutation of transformers
during the connection phase, due to the phenomenon of
magnetization.
Switching of capacitor banks.
High peaks of current characterize the commutation of capacitor
banks during the connection phase, due to the presence of
harmonic currents.
AC4
AC5a
AC5b
AC6a
AC6b
DC5
DC6
Connection or disconnection of non-inductive or slightly inductive
loads (e.g. resistance furnaces).
This equipment should operate with a L/R time-constant less than
or equal to 1ms.
Starting, plugging and inching of shunt-motors. Dynamic breaking
of DC motors.
This equipment should operate with a L/R time-constant less than
or equal to 2,5ms.
The contactor makes and breaks the starting current, which is close
to 2,5 times the rated current of the motor.
The switching conditions are severe, as the voltage at the motor
terminals can be equal to that of the supply voltage.
Starting, plugging and inching of series-motors. Dynamic breaking
of DC motors.
This equipment should operate with a L/R time-constant less than
or equal to 15ms.
The contactor makes and breaks the starting current, which is close
to 2,5 times the rated current of the motor.
The switching conditions are severe, as the voltage at the motor
terminals can be equal to that of the supply voltage.
Switching of incandescent lamps.
Power equipment, switchgear and controlgear according
to EN 60947-3 and IEC 947-3
(switches, disconnectors, switch-disconnectors, fuse-combination units)
DC20 Connecting and disconnecting under no-load conditions.
DC21 Switching of resistive loads including moderate overloads.
DC22 Switching of mixed resistive and inductive loads, including
moderate overloads (e.g. shunt-motors).
DC23 Switching of highly inductive loads (e.g. series-motors).
Power equipment, switchgear and controlgear according
to EN 60947-3 and IEC 947-3
(switches, disconnectors, switch-disconnectors, fuse-combination units)
Control circuit devices and switching elements according
to EN 60947-5 and IEC 947-5
(control relays, auxiliary contacts, units for control and signalling)
AC20 Connecting and disconnecting under no-load conditions.
AC21 Switching of resistive loads including moderate overloads.
AC22 Switching of mixed resistive and inductive loads, including
moderate overloads.
DC12 Control of resistive loads and solid state loads with isolation by
optocouplers.
DC13 Control of electromagnets without economy resistor in circuit.
DC14 Control of electromagnetic loads having economy resistor in circuit.
AC23 Switching of motor loads or other highly inductive loads.
Control circuit devices and switching elements according
to EN 60947-5 and IEC 947-5
(control relays, auxiliary contacts, units for control and signalling)
AC12 Control of resistive loads and solid-state loads with isolation by
optocouplers.
AC13 Control of solid state loads with transformer isolation.
AC14 Control of small electromagnetic loads ( ≤ 72VA).
AC15 Control of electromagnetic loads ( > 72VA).
- By plugging is understood stopping or reversing the motor rapidly by
reversing motor primary connections while the motor is running.
- By inching (jogging) is understood energizing a motor once or repeatedly
for short periods to obtain small movements of the driven mechanism.
- The designation of AC20-AC21-AC22-AC23-DC20-DC21-DC22-DC23
utilization categories is completed by the suffix A or B according to
wheter the intended applications require frequent or infrequent
operations.
Utilization categories with suffix B are appropriate for devices which, due
to design or application, are only intended for infrequent operation (e.g.
disconnectors normally only operated to provide isolation for
maintenance work).
29
TECHNICAL INFORMATION - CABLE DIMENSIONS TABLE
Standard cross-sections of round copper conductors
corresponding to the conventional thermal currents
Range of rated thermal current ■
A
0
8
8
12
12
15
15
20
20
25
25
32
32
50
50
65
65
85
85
100
100
115
115
130
130
150
150
175
175
200
200
225
225
250
250
275
275
300
300
350
350
400
400
500
500
630
630
800
Range of rated thermal current ■
A
400
500
500
630
630
800
800
1000
1000
1250
1250
1600
1600
2000
2000
2500
2500
3150
Section of2 copper conductors / cables
mm
AWG/MCM
1
18
1,5
16
2,5
14
2,5
12
4
10
6
10
10
8
16
6
25
4
35
3
35
2
50
1
50
0
70
00
95
000
95
0000
120
250
150
300
185
350
185
400
240
500
2x150
2x250
2x185
2x350
2x240
2x300
Section of copper bars ▲
N°
mm
inch
2
30x5 1.00x0.250
2
40x5 1.25x0.250
2
50x5 1.50x0.250
2
60x5 2.00x0.250
2
80x5 2.50x0.250
2
100x5 3.00x0.250
3
100x5 3.00x0.250
4
100x5 3.00x0.250
3
100x10 6.00x0.250
■ The current value should always be greater than the left-hand value and less than or equal
to the right-hand value.
▲ Bars are assumed to be arranged with their long faces vertical. Arrangements with long
faces horizontal may be used if specified by the manufacturer.
Where 4 bars are used they shall be in two sets of two bars with not more than 100mm
between pair centres.
30
TECHNICAL INFORMATION - PROTECTION DEGREES
The International Recommendations IEC 529 to which the single national standards refer, as well as the European Harmonized Standards EN 60529 and EN
50102, classify the degree of protection provided by the enclosures for electrical equipment as regards:
a) protection of the persons against access to hazardous parts inside the enclosure (e.g. low-voltage live parts, mechanical parts).
b) protection of the equipment inside the enclosure against ingress of solid foreign objects.
c) protection of the equipment inside the enclosure against the harmful effects due to the ingress of water.
d) protection of the enclosure against damage due to harmful external mechanical impacts.
The degrees of protection relating to the first three items are designed by the IP part no, followed by a combination of two characteristic numerals, to which a
first additional letter and a second supplementary letter, both optional, can be added.
IP Part no
First characteristic numeral
Second characteristic numeral
Protection against ingress of solid objects.
Protection against harmful ingress of water
Protection of persons against access to hazardous
parts.
0
No protection.
1
Full penetration of 50 mm
diameter sphere not
allowed.
Protection against access
with the back of a hand.
IK Part no
Characteristic group numeral
Protection against harmful external mechanical
impacts.
0
No protection.
1
Protection against
vertically falling drops of
water.
Limited ingress permitted.
01
2
Full penetration of 12,5
mm diameter sphere not
allowed.
Protection against access
with a finger.
2
Protected against vertically
falling drops of water with
enclosure tilted 15° from the
vertical. Limited ingress permitted.
Dripping up to 15° from the vertical.
02
3
The access probe of 2,5
mm diameter shall not
penetrate.
Protection against access
with a tool.
3
Protected against sprays
to 60° from the vertical.
Limited ingress permitted.
Limited spraying.
03
4
The access probe of 1,0
mm diameter shall not
penetrate.
Protection against
4
Protected against water
splashed from all
directions. Limited ingress
permitted. Splashing from
all directions.
04
5
Limited ingress of dust
permitted (no harmful
deposit).
Protection against access
with a wire.
5
Protected against jets of
water.
Limited ingress permitted.
Hosing jets from all
directions.
05
6
Total protection against
ingress of dust.
Protection against access
with a wire.
6
Protected against strong
jets of water.
Limited ingress permitted.
Strong hosing jets from all
directions.
06
Protected against the
effects of immersion
between 15 cm and 1 m.
Temporary immersion.
07
Protected against long
periods of immersion
under pressure.
Continuous immersion
08
29,5 cm
09
20 cm
10
40 cm
15 cm mini ↕
7
1m
m
8
0
No protection.
Resistance to impact of a
mass of 200 g with a
striking energy of 0,15 J.
20
0g
7,5 cm
Resistance to impact of a
mass of 200 g with a
striking energy of 0,20 J.
20
0g
10 cm
20
Resistance to impact of a
mass of 200 g with a
striking energy of 0,35 J.
20
Resistance to impact of a
mass of 200 g with a
striking energy of 0,50 J.
20
0g
Resistance to impact of a
mass of 200 g with a
striking energy of 0,70 J.
50
Resistance to impact of a
mass of 500 g with a
striking energy of 1 J.
0g
17,5 cm
0g
25 cm
25 cm
0g
20 cm
50
0g
Resistance to impact of a
mass of 500 g with a
striking energy of 2 J.
40 cm
1,7
kg
5k
g
5k
g
When the equipment is classified for one of the two main types of protection only, that is to say with
only one numeral, the omitted numeral should be replaced with the letter X (e.g. IPX5 or IP2X).
Resistance to impact of a
mass of 1,7 kg with a
striking energy of 5 J.
Resistance to impact of a
mass of 5 kg with a
striking energy of 10 J.
Resistance to impact of a
mass of 5 kg with a
striking energy of 20 J.
31
TECHNICAL INFORMATION - RATED MOTOR CURRENTS
3-phases motors
Single-phase motors
Rated current of the motor and the recommended aM fuses
Rated current
Potenza
Power
220-230 V
380-400 V
415 V
440 V
500 V
220 / 230 V
kW
CV
motor
A
aM
A
motor
A
aM
A
motor
A
aM
A
motor
A
aM
A
motor
A
aM
A
0,37
0,55
0,75
1,1
1,5
2,2
3
3,7
4
5,5
7,5
9
10
11
13
15
18,5
22
25
30
33
37
40
45
51
55
59
63
75
80
85
90
100
110
129
132
140
147
150
160
180
185
200
220
280
295
300
335
355
0,5
0,75
1
1.5
2
3
4
5
5,5
7,5
10
12
13,5
15
17,5
20
25
30
35
40
45
50
54
60
70
75
80
85
100
110
115
125
136
150
175
180
190
200
205
220
245
250
270
300
380
400
410
450
480
1,8
2,75
3,5
4,4
6,1
8,7
11,5
13,5
14,5
20
27
32
35
39
45
52
64
75
85
103
113
126
134
150
170
182
195
203
240
260
280
295
325
356
420
425
450
472
483
520
578
595
626
700
900
950
980
1100
1150
2
4
4
6
8
10
12
16
16
20
32
32
40
40
50
63
63
80
100
125
125
160
160
160
200
200
200
250
250
315
315
315
400
400
500
500
500
500
500
630
630
630
630
800
1000
1000
1000
1200
1200
1,03
1,6
2
2,6
3,5
5
6,6
7,7
8,5
11,5
15,5
18,5
20
22
26
30
37
44
52
60
68
72
79
85
98
105
112
117
138
147
156
170
188
205
242
245
260
273
280
300
333
342
370
408
510
550
565
620
636
2
2
2
4
4
6
8
8
10
12
16
20
20
25
32
32
40
50
63
63
80
80
80
100
100
125
125
125
160
160
160
200
200
250
250
250
315
315
315
315
400
400
400
500
630
630
630
630
800
1
1,5
2
2.5
3,5
5
6,5
7,5
8,4
11
14
17
19
21
25
28
35
40
47
55
60
66
71
80
90
100
105
115
135
138
147
165
182
200
230
240
250
260
270
280
320
325
340
385
475
500
510
550
580
2
2
2
4
4
6
8
8
10
12
16
20
20
25
25
32
40
40
50
63
63
80
80
80
100
100
125
125
160
160
160
200
200
200
250
250
250
315
315
315
400
400
400
400
500
500
630
630
630
1
1,36
1,68
2,37
3,06
4,42
5,77
7,1
7,9
10,4
13,7
16,9
18,5
20,1
21,9
26,5
32,8
39
45,3
51,5
58
64
67
76
83
90
97
109
125
131
139
146
162
178
209
215
227
236
246
256
289
295
321
353
448
473
483
518
549
2
2
2
4
4
6
8
8
8
12
20
20
20
25
25
32
40
40
50
63
63
80
80
80
100
100
100
125
125
160
160
160
200
200
250
250
250
250
250
315
315
315
400
400
500
500
500
630
630
1
1,21
1,5
2
2,6
3,8
5
5,9
6,5
9
12
13,9
15
18,4
20,5
23
28,5
33
39,4
45
50
55
60
65
75
80
85
89
105
112
118
129
143
156
184
187
200
207
210
220
254
263
281
310
400
416
420
472
500
2
2
2
2
4
4
6
6
8
10
12
20
20
20
25
25
32
40
40
50
63
63
63
80
80
80
100
100
125
125
125
160
160
160
200
200
200
250
250
250
315
315
315
315
400
500
500
500
500
kW
CV
motor
A
aM
A
0,07
0,1
0,12
0,18
0,25
0,37
0,55
0,75
1,1
1,5
1,8
2,2
3
4
4,4
5,2
5,5
6
7
7,5
1/12
1/8
1/6
1/4
1/3
0,5
0,75
1
1,5
2
2,5
3
4
5
6
7
7,5
8
9
10
1,2
1,6
1,9
2,3
2,9
3,9
5,2
6,6
9,6
12,7
15,7
18,6
24,3
29,6
34,7
39,8
42,5
44,5
49,5
54,4
2
2
2
4
4
4
6
6
10
16
16
20
25
32
40
40
50
50
50
63
Notes
The table contains the value of the current absorbed by the motor and the corresponding aM fuse for protection against short-circuit.
The current values indicated refer to those absorbed at full load by 3-phase squirrel-cage motors, 4 pole, 1500 rpm, 50 Hz, and by single-phase motors.
These values are approximate, as they can slightly change according to the type of motor and the manufacturer.
The thermal overload relay should therefore be adjusted for the current indicated on the motor nameplate and the rating of the fuse should be in proportion to this value,if
different from that given in the table.
32
TECHNICAL INFORMATION - CO-ORDINATION WITH SHORT-CIRCUIT PROTECTIVE DEVICE
When a disconnector, a contactor, a thermal overload relay, an automatic circuit breaker or a set of three fuses are chosen to realizes a plant, the problem of
their mutual behaviour arises, that is to say their “co-ordination” on the basis of the electrical function carried out by each device.
Symbol
Device
Function
Notes
Switch
Control
It makes, carries and switches the currents up to its making and breaking
capacity.
Being a device characterised usually by a limited breaking capacity, it is not able
to switch high over-currents as those of short-circuit.
Thermal overload
relay
Protection
against
overcurrent and
phase failure
It protects against thermal overloads included between 1,2 and times the rated
current of the load (up to locked rotor condition, case of motors).
This relay is characterised by a precise limit, represented by the max specific
passing energy, beyond which an alteration of its tripping characteristic may
occurs and, as an extreme case, the fusion of the heater elements. In fact, the
thermal overload relay points out only the overload condition, delegating the real
protection to the contactor, which switches the circuit.
Fuses
Protection
against
short-circuits
They have not to trip in presence of a normal current overload.
In order to avoid the fusion during the current peak which occurs
motor starting, the fuse type gG will be chosen sized from 1,5 to 2,5 the full load
current of the motor. Such fuse has therefore to carry for a relatively long time a
current higher than the rated one and this may cause a thermal overload
dangerous for the motor. In order to assure an effective protection of the motor,
it is recommended to couple the thermal overload relay with fuses type aM
(motor accompanying) whose current is of the same order of size than the
current of themotor to be protected.
Disconnector
Disconnection
This device allow to insulate, in a total and sure way, all the conductors placed
on the load side, before carrying out any intervention on the plant, following a
failure or a need of maintenance.
Switch-disconnector
Control
Disconnection
It groups all the above mentioned functions, relating to disconnector.
Automatic circuit
braker
Control
Protection against
overloads
Protection
against
short-circuits
Direct-on-line
starter
Control
Protection
against
overloads
It groups more than one of the above mentioned functions.
This equipment consists of a contactor coupled to a thermal overload relay, able
of starting, stopping and protecting a motor.
Notes
The protective device (fuse or automatic circuit breaker) should be chosen in such a way to co-ordinate the starter for failure currents which exceed the
breaking capacity of the contactor or the limit let through energy of the thermal overload relay.
The device should be located on the supply side of the starter and have a short-circuit breaking capacity not less than the short-circuit prospective current
at its location. “Fuse-combination unit” is a general term covering the combination of a switch, a disconnector or a switch-disconnector and one or more
fuses in a composite unit.
Such unit performs the different functions carried out by each electrical device composing the unit
33
PROGRESSIVE PART No. INDEX
Part no.
ord.
VC211100
VC218600
VC286300
VC290500
VC291300
VC298800
VC300200
VC301000
VC302800
VC303600
VC304400
VD420700
VD421500
VD422300
VD423100
VD424900
VD425600
VD428000
VD429800
VD430600
VD431400
VD432200
VD433000
VD434800
VD435500
VD444700
VD445400
VD446200
VD447000
VD448800
VD449600
VD450400
VD451200
VD452000
VD453800
VD454600
VD455300
VD456100
VD457900
VD459500
VD460300
VI806200
VI807000
VI808800
VI809600
VQ329600
VQ330400
VQ332000
VQ333800
VQ335300
VQ336100
VQ338700
VQ339500
VQ341100
VQ342900
VQ344500
VQ345200
VQ347800
VQ348600
VQ350200
VQ351000
VQ353600
VQ354400
VQ355100
VQ356900
VQ357700
34
Type no.
B-G1280
B-KG6047
B-G813
XA0503BSP
XA0504BSP
XC050PB
XC16AN
XC16CN
XC32AN
XC32CN
XC32GN
XA0633BSP
XA0634BSP
XA0803BSP
XA0804BSP
XA1003BSP
XA1004BSP
XA0503BSL
XA0504BSL
XA0633BSL
XA0634BSL
XA0803BSL
XA0804BSL
XA1003BSL
XA1004BSL
XA0503BSN
XA0504BSN
XA0633BSN
XA0634BSN
XA0803BSN
XA0804BSN
XA1003BSN
XA1004BSN
XC063PB
XC080PB
XC100PB
XC100GB
B-G1305
B-G1304
XC012AB
XC012CB
XA0633BDSP
XA0503BDSP
XA0633BCSP
XA0503BCSP
KNZ16B3000
KNZ16B4000
KNZ16G3000
KNZ16G4000
KNZ16R3000
KNZ16R4000
KNZ30B3000
KNZ30B4000
KNZ30G3000
KNZ30G4000
KNZ30R3000
KNZ30R4000
KNZ40B3000
KNZ40B4000
KNZ40G3000
KNZ40G4000
KNZ40R3000
KNZ40R4000
XNA0503B
XNA0633B
XNA0803B
IPage
13
13
13
11
11
12
12
12
12
12
12
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
12
12
12
12
13
13
12
12
11
11
11
11
6
6
8
8
6
6
6
6
8
8
6
6
6
6
8
8
6
6
6
6
6
Part no.
ord.
VQ358500
VQ362700
VQ363500
VQ364300
VQ365000
VQ366800
VQ367600
VQ380900
VQ381700
VQ382500
VQ383300
VQ384100
VQ385800
VQ387400
VQ388200
VQ389000
VQ391600
VQ392400
VQ393200
VQ403900
VQ404700
VQ405400
VQ407000
VQ408800
VQ409600
VQ413800
VQ416100
VQ422900
VQ425200
VQ428600
VQ429400
VQ430200
VQ431000
VQ432800
VQ433600
VQ434400
VQ436900
VQ438500
VQ439300
VQ441900
VQ442700
VQ446800
VQ447600
VQ448400
VQ449200
Z0063400
ZN869700
ZN880800
ZN880900
ZN881000
ZN881100
ZN881200
ZN881300
ZN881400
ZN881500
ZN881600
ZN881700
ZN882200
ZO061200
ZO061300
ZO061600
ZO061700
ZO062000
ZO062100
ZO062400
ZO062500
Type no.
XNA1003B
XNA163B
XNA163G
XNA163R
XNA164B
XNA164G
XNA164R
XNA323B
XNA323G
XNA323R
XNA324B
XNA324G
XNA324R
XNA1630BXL
XNA1630BXN
XNA1630BXP
XNA1640BXL
XNA1640BXN
XNA1640BXP
XNA3230BXL
XNA3230BXN
XNA3230BXP
XNA3240BXL
XNA3240BXN
XNA3240BXP
XNF163B
XNF164B
XNF323B
XNF324B
YNGK6
YNGL6
YNGT4
YNGT6
YNGY4
YNGY6
YNUK6
YNUL6
YNUT4
YNUT6
YNUY4
YNUY6
B-GNAM0
B-GNAP0
B-GNAP1
B-GNAP2
KNZ40B4000BYP
B-GNAP4
XNA0503BC
XNA0504BC
XNA0633BC
XNA0634BC
XNA0803BC
XNA0804BC
XNA1003BC
XNA1004BC
YNUT6C
YNUL6C
YNUK6C
KNZ16B3000BYL
KNZ16B3000BYN
KNZ16B4000BYL
KNZ16B4000BYN
KNZ30B3000BYL
KNZ30B3000BYN
KNZ30B4000BYL
KNZ30B4000BYN
IPage
6
6
8
6
6
8
6
6
8
6
6
8
6
10
10
10
10
10
10
10
10
10
10
10
10
6
6
6
6
8
8
8
8
8
8
7
7
7
7
7
7
13
13
13
13
9
13
7
7
7
7
7
7
7
7
7
7
7
9
9
9
9
9
9
9
9
Part no.
ord.
ZO062600
ZO062800
ZO062900
ZO063000
ZO063200
ZO063300
ZOO61400
ZOO61800
ZOO62200
Type no.
KNZ30B4000BYP
KNZ40B3000BYL
KNZ40B3000BYN
KNZ40B3000BYP
KNZ40B4000BYL
KNZ40B4000BYN
KNZ16B3000BYP
KNZ16B4000BYP
KNZ30B3000BYP
IPage
9
9
9
9
9
9
9
9
9
PROGRESSIVE TYPE No. INDEX
Type no.
ord.
B-G1280
B-G1304
B-G1305
B-G813
B-GNAM0
B-GNAP0
B-GNAP1
B-GNAP2
B-GNAP4
B-KG6047
KNZ16B3000
KNZ16B3000BYL
KNZ16B3000BYN
KNZ16B3000BYP
KNZ16B4000
KNZ16B4000BYL
KNZ16B4000BYN
KNZ16B4000BYP
KNZ16G3000
KNZ16G4000
KNZ16R3000
KNZ16R4000
KNZ30B3000
KNZ30B3000BYL
KNZ30B3000BYN
KNZ30B3000BYP
KNZ30B4000
KNZ30B4000BYL
KNZ30B4000BYN
KNZ30B4000BYP
KNZ30G3000
KNZ30G4000
KNZ30R3000
KNZ30R4000
KNZ40B3000
KNZ40B3000BYL
KNZ40B3000BYN
KNZ40B3000BYP
KNZ40B4000
KNZ40B4000BYL
KNZ40B4000BYN
KNZ40B4000BYP
KNZ40G3000
KNZ40G4000
KNZ40R3000
KNZ40R4000
XA0503BCSP
XA0503BDSP
XA0503BSL
XA0503BSN
XA0503BSP
XA0504BSL
XA0504BSN
XA0504BSP
XA0633BCSP
XA0633BDSP
XA0633BSL
XA0633BSN
XA0633BSP
XA0634BSL
XA0634BSN
XA0634BSP
XA0803BSL
XA0803BSN
XA0803BSP
XA0804BSL
Part no.
VC211100
VD457900
VD456100
VC286300
VQ446800
VQ447600
VQ448400
VQ449200
ZN869700
VC218600
VQ329600
ZO061200
ZO061300
ZOO61400
VQ330400
ZO061600
ZO061700
ZOO61800
VQ332000
VQ333800
VQ335300
VQ336100
VQ338700
ZO062000
ZO062100
ZOO62200
VQ339500
ZO062400
ZO062500
ZO062600
VQ341100
VQ342900
VQ344500
VQ345200
VQ347800
ZO062800
ZO062900
ZO063000
VQ348600
ZO063200
ZO063300
Z0063400
VQ350200
VQ351000
VQ353600
VQ354400
VI809600
VI807000
VD428000
VD444700
VC290500
VD429800
VD445400
VC291300
VI808800
VI806200
VD430600
VD446200
VD420700
VD431400
VD447000
VD421500
VD432200
VD448800
VD422300
VD433000
IPage
13
13
13
13
13
13
13
13
13
13
6
9
9
9
6
9
9
9
8
8
6
6
6
9
9
9
6
9
9
9
8
8
6
6
6
9
9
9
6
9
9
9
8
8
6
6
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
Type no.
ord.
XA0804BSN
XA0804BSP
XA1003BSL
XA1003BSN
XA1003BSP
XA1004BSL
XA1004BSN
XA1004BSP
XC012AB
XC012CB
XC050PB
XC063PB
XC080PB
XC100GB
XC100PB
XC16AN
XC16CN
XC32AN
XC32CN
XC32GN
XNA0503B
XNA0503BC
XNA0504BC
XNA0633B
XNA0633BC
XNA0634BC
XNA0803B
XNA0803BC
XNA0804BC
XNA1003B
XNA1003BC
XNA1004BC
XNA1630BXL
XNA1630BXN
XNA1630BXP
XNA163B
XNA163G
XNA163R
XNA1640BXL
XNA1640BXN
XNA1640BXP
XNA164B
XNA164G
XNA164R
XNA3230BXL
XNA3230BXN
XNA3230BXP
XNA323B
XNA323G
XNA323R
XNA3240BXL
XNA3240BXN
XNA3240BXP
XNA324B
XNA324G
XNA324R
XNF163B
XNF164B
XNF323B
XNF324B
YNGK6
YNGL6
YNGT4
YNGT6
YNGY4
YNGY6
Part no.
VD449600
VD423100
VD434800
VD450400
VD424900
VD435500
VD451200
VD425600
VD459500
VD460300
VC298800
VD452000
VD453800
VD455300
VD454600
VC300200
VC301000
VC302800
VC303600
VC304400
VQ355100
ZN880800
ZN880900
VQ356900
ZN881000
ZN881100
VQ357700
ZN881200
ZN881300
VQ358500
ZN881400
ZN881500
VQ387400
VQ388200
VQ389000
VQ362700
VQ363500
VQ364300
VQ391600
VQ392400
VQ393200
VQ365000
VQ366800
VQ367600
VQ403900
VQ404700
VQ405400
VQ380900
VQ381700
VQ382500
VQ407000
VQ408800
VQ409600
VQ383300
VQ384100
VQ385800
VQ413800
VQ416100
VQ422900
VQ425200
VQ428600
VQ429400
VQ430200
VQ431000
VQ432800
VQ433600
IPage
11
11
11
11
11
11
11
11
12
12
12
12
12
12
12
12
12
12
12
12
6
7
7
6
7
7
6
7
7
6
7
7
10
10
10
6
8
6
10
10
10
6
8
6
10
10
10
6
8
6
10
10
10
6
8
6
6
6
6
6
8
8
8
8
8
8
Type no.
ord.
YNUK6
YNUK6C
YNUL6
YNUL6C
YNUT4
YNUT6
YNUT6C
YNUY4
YNUY6
Part no.
VQ434400
ZN882200
VQ436900
ZN881700
VQ438500
VQ439300
ZN881600
VQ441900
VQ442700
IPage
7
7
7
7
7
7
7
7
7
35
NOTE
36