Bremas sezionatori GB.qxd
Transcription
Bremas sezionatori GB.qxd
Industrial Automation For over 40 years, BREMAS has been producing electro mechanical products such us switches dedicated to applications as food processing machinery, wood working machinery, welding machines, lifts, water management, productions lines, power tools and electricity supply systems and many others. Wide experience has allowed BREMAS to become a specialist in the industrial automation field and to be able to address specific customer requests through customized solutions. BREMAS is known for having achieved high quality standards certified by the most important entities ( , e ). The company is focused on the evolution of the industrial automation market in order to be able to provide the most complete and flexible solutions to every applications requirement. The parts and components of Bremas products are made of the most advanced materials that can guarantee the compliance to the most important quality standards and safety requirements. BREMAS product range includes: cam switches, switch disconnectors, power tools switches, control and signalling units Ø22, foot switches. BREMAS ERSCE S.p.A. I-20060 Liscate (MI) - Via Milano, 26 - Tel. +39.02.95651611 Fax. +39.02.95651639 - [email protected] www.bremas.it SWITCHES IP20 Rear mounting KNZ series HANDLE DEVICE IP65 XNA series Front mounting with screw YNUT4 Grey/Black YNGT4 Grey/Black YNUY4 Yellow/Red YNGY4 Yellow/Red Plate 48x48 YNUT6 Grey/Black YNGT6 Grey/Black YNUY6 Yellow/Red YNGY6 Yellow/Red YNUT6C Grey/Black Front mounting in centre hole ø22 mm XNA series XNF series XNA series change-over Base mounting KNZ series Plate 67x67 DIN rail mounting YNUK6 Grey/Black YNGK6 Grey/Black YNUL6 Yellow/Red YNGL6 Yellow/Red YNUK6C Grey/Black YNUL6C Yellow/Red Plate with padlock 67x67 ACCESSORIES Base fixing plate 2 Shaft extension for door interlock device B-GNAPX / B-GNAMO Terminals cover KNZ 16-30-40 Terminals cover XNA XNF 16-32 ENCLOSED VERSION IP65 ENCLOSED VERSION IP55 KNZ 16-30-40 series XA 50-63-80-100 series Plate with padlock (Emergency) Grey plate and black knob Plate with padlock (Emergency) Change-over / double-ways XA 50-63 series XNA 16-32 series Plate with padlock (Emergency) Grey plate and black knob Grey plate and black knob Grey plate and black knob ACCESSORI XNA-XNF 16-32A Terminals cover XNA 50-63-80-100A Part no. XC16CN XC16AN XC32CN XC32AN XC32GN Type no. 1NO 1NC 1NO 1NC PE XNA 50-63-80-100A Part no. XC012AB XC012CB XC100GB XC050PB XC063PB XC080PB XC100PB Type no. 1NO 1NC PE N N N N Auxiliary contacts and additional poles 3 OVERVIEW KNZ, XNA switch-disconnectors designed for the switching and isolation of electrical machinery power supply lines. Also available in XNF fused version for protection against over-currents. XNA Box terminals Terminals protection degree IP20 Open hooded terminal connectors with dual slot screw Silver alloy terminal plates with dual switching on positive opening Ratings 16 up to 100 A XNF with fuses Ratings 16 up to 32 A Auxiliary contact and additional poles PE and N may be added. KNZ Ratings 16 up to 40 A The IP65 handle device are available in versions: Standard gray-black and yellow-red(emergency) in two dimensions 67x67 mm 48x48 mm White plastic insert used as manoeuvre indicator and fixing screw cover for the knob to the shaft Locking grey-black and yellow-red (emergency) 67x67 mm When ordering, indicate the codes for the switch (bodies) and handle device, as the two products are handled separately 4 OVERVIEW Available in three and four poles versions Available with four different mounting systems Rear mounting with screw ■ A complete range of accessories allow the installation on the panel with 32 mm or 28 mm fixing distance screws. Rear mounting Ø22 mm ■ Easy and fast installation. The connections between the switch and the front trim plate is allowed by a snap-on fixing system. Base mounting ■ With a door locking device to attach the finishing structure to the terminal in the On position. The door locking function guarantee the safety at the application against accidental opening cabinet. The switch can be equipped with two different shaft extenction telescopic or modular. + + Telescopic Modular Enclosed version ■ Version in IP65 insulating box. The container has four PG hole inlets for the cable. When ordering, indicate the codes for the switch (bodies) and handle device, as the two products are handled separately 5 STANDARD VERSIONS Rear mounting with screw KNZ - Switch-disconnectors 0-1 3 poles Part no. Type no. VQ335300 KNZ16R3000 VQ344500 KNZ30R3000 VQ353600 KNZ40R3000 4 poles Part no. Type no. VQ336100 KNZ16R4000 VQ345200 KNZ30R4000 VQ354400 KNZ40R4000 Rated operat. Rated operat. current power AC21 AC23 16 A 30 A 40 A 11 Kw 15 Kw 22 Kw Rated operat. current AC21 16 A 32 A Rated operat. power AC23 15 Kw 22 Kw XNA - Switch-disconnectors 0-1 3 poles 4 poles Part no. Type no. VQ364300 XNA163R VQ382500 XNA323R Part no. Type no. VQ367600 XNA164R VQ385800 XNA324R Base mounting KNZ - Switch-disconnectors 0-1 (*) 3 poles Part no. VQ329600 VQ338700 VQ347800 Type no. KNZ16B3000 KNZ30B3000 KNZ40B3000 4 poles Part no. VQ330400 VQ339500 VQ348600 Type no. KNZ16B4000 KNZ30B4000 KNZ40B4000 Rated operat. current AC21 16 A 30 A 40 A Rated operat. power AC23 11 Kw 15 Kw 22 Kw Rated operat. current AC21 16 A 32 A 50 A 63 A 80 A 100 A Rated operat. power AC23 15 Kw 22 Kw 18.5 Kw 18.5 Kw 22 Kw 30 Kw Rated operat. current AC21 16 A 32 A Rated operat. power AC23 15 Kw 22 Kw XNA - Switch-disconnectors 0-1 (*) 3 poles Part no. VQ362700 VQ380900 VQ355100 VQ356900 VQ357700 VQ358500 Type no. XNA163B XNA323B XNA0503B XNA0633B XNA0803B XNA1003B 4 poles Part no. Type no. VQ365000 XNA164B VQ383300 XNA324B XNF - Switch-disconnectors 0-1 (*) 3 poles Part no. Type no. VQ413800 XNF163B VQ422900 XNF323B • Dimensions, see page 15-16 • Circuit diagrams, see page 14 • Accessories, see page 12-13 • Technical data, see page 24-25 4 poles Part no. Type no. VQ416100 XNF164B VQ425200 XNF324B (*) The switch can be installed without extenction shaft for maximum distance between the panel and the door locking bracket device of 9 mm. When ordering, indicate the codes for the switch (bodies) and handle device, as the two products are handled separately 6 STANDARD VERSIONS Base mounting XNA - Change-over switch 1-0-2 3 poles Part no. ZN880800 ZN881000 ZN881200 ZN881400 (*) 4 poles Type no. XNA0503BC XNA0633BC XNA0803BC XNA1003BC Part no. ZN880900 ZN881100 ZN881300 ZN881500 Rated operat. current AC21 50 A 63 A 80 A 100 A Type no. XNA0504BC XNA0634BC XNA0804BC XNA1004BC Rated operat. power AC23 18.5 Kw 18.5 Kw 22 Kw 30 Kw (*) The switch can be installed without extenction shaft for maximum distance between the panel and the door locking bracket device of 9 mm. • Dimensions, see page 15-16 • Circuit diagrams, see page 14 • Accessories, see page 12-13 • Technical data, see page 24-25 Handle device for rear mounting with screw and base mounting KNZ-XNA-XNF series IP65 Type no. Plate dim. YNUT4 48 YNUT6 67 YNUT6C 67 IP65 Yellow plate with padlock in “0” position and red knob (Emergency) Grey plate and black knob Part no. VQ438500 VQ439300 ZN881600 KNZ-XNA-XNF series Plate for switch 0-1 switch 0-1 change-over switch 1-0-2 KNZ-XNA-XNF series IP65 Part no. Type no. VQ436900 YNUL6 ZN881700 YNUL6C Plate dim. 67 67 KNZ-XNA-XNF series Plate for switch 0-1 change-over switch 1-0-2 IP65 Yellow plate and red knob (Emergency) Grey plate with padlock in “0” position and black knob Part no. Type no. VQ441900 YNUY4 VQ442700 YNUY6 Part no. Type no. Plate dim. VQ434400 YNUK6 67 ZN882200 YNUK6C 67 Plate dim. 48 67 Plate for switch 0-1 switch 0-1 Plate for switch 0-1 change-over switch 1-0-2 • Dimensions, see page 17 When ordering, indicate the codes for the switch (bodies) and handle device, as the two products are handled separately 7 STANDARD VERSIONS Rear mounting Ø 22 mm KNZ - Switch-disconnectors 0-1 3 poles Part no. VQ332000 VQ341100 VQ350200 4 poles Type no. KNZ16G3000 KNZ30G3000 KNZ40G3000 Part no. VQ333800 VQ342900 VQ351000 Type no. KNZ16G4000 KNZ30G4000 KNZ40G4000 Rated operat. current AC21 16 A 30 A 40 A Rated operat. power AC23 11 Kw 15 Kw 22 Kw Rated operat. current AC21 16 A 32 A Rated operat. power AC23 15 Kw 22 Kw XNA - Switch-disconnectors 0-1 3 poles 4 poles Part no. Type no. VQ363500 XNA163G VQ381700 XNA323G Part no. Type no. VQ366800 XNA164G VQ384100 XNA324G • Dimensions, see page 15-16 • Circuit diagrams, see page 14 • Accessories, see page 12-13 • Technical data, see page 24-25 Handle device for rear mounting Ø22 mm KNZ-XNA-XNF series IP65 Plate dim. 48 67 KNZ-XNA-XNF series IP65 Yellow plate and red knob (Emergency) Grey plate and black knob Part no. Type no. VQ430200 YNGT4 VQ431000 YNGT6 KNZ-XNA-XNF series Plate for switch 0-1 switch 0-1 IP65 Part no. Type no. VQ432800 YNGY4 VQ433600 YNGY6 Plate dim. 48 67 KNZ-XNA-XNF series Plate for switch 0-1 switch 0-1 IP65 Yellow plate with padlock in “0” position and red knob (Emergency) Grey plate with padlock in “0” position and black knob Part no. Type no. VQ429400 YNGL6 Part no. Type no. VQ428600 YNGK6 Plate dim. 67 Plate for switch 0-1 Plate dim. 67 Plate for switch 0-1 • Dimensions, see page 18 When ordering, indicate the codes for the switch (bodies) and handle device, as the two products are handled separately 8 STANDARD VERSIONS Enclosed KNZ series BYP version(*) IP65 Switch with grey plate and black knob 3 poles Part no. ZO061400 ZO062200 ZO063000 4 poles Type no. KNZ16B3000BYP KNZ30B3000BYP KNZ40B3000BYP KNZ series Part no. ZO061800 ZO062600 ZO063400 Type no. KNZ16B4000BYP KNZ30B4000BYP KNZ40B4000BYP Rated operat. current AC21 16 A 30 A 40 A BYN version(*) Rated operat. power AC23 11 Kw 15 Kw 22 Kw IP65 Main switch with padlock in ‘0’ position, grey plate and black knob 3 poles Part no. ZO061300 ZO062100 ZO062900 4 poles Type no. KNZ16B3000BYN KNZ30B3000BYN KNZ40B3000BYN KNZ series Part no. ZO061700 ZO062500 ZO063300 Type no. KNZ16B4000BYN KNZ30B4000BYN KNZ40B4000BYN Rated operat. current AC21 16 A 30 A 40 A BYL version(*) Rated operat. power AC23 11 Kw 15 Kw 22 Kw IP65 Emergency main switch with padlock in ‘0’ position, yellow plate and red knob 3 poles Part no. ZO061200 ZO062000 ZO062800 Type no. KNZ16B3000BYL KNZ30B3000BYL KNZ40B3000BYL 4 poles Part no. ZO061600 ZO062400 ZO063200 Type no. KNZ16B4000BYL KNZ30B4000BYL KNZ40B4000BYL Rated operat. current AC21 16 A 30 A 40 A Rated operat. power AC23 11 Kw 15 Kw 22 Kw (*) An auxiliary contact and a neutral pole may be added. See page 12, accessories: “Auxiliary contacts and additional poles for base mounting” • Dimensions, see page 22 • Circuit diagrams, see page 14 • Technical data, see page 24-25 9 STANDARD VERSIONS Enclosed XNA series BXP version(*) IP65 Switch with grey plate and black knob 3 poles 4 poles Part no. Type no. • VQ389000 XNA1630BXP • VQ405400 XNA3230BXP Part no. Type no. • VQ393200 XNA1640BXP VQ409600 XNA3240BXP Rated operat. current AC21 16 A 32 A Rated operat. power AC23 15 Kw 22 Kw (•) Available on request XNA series BXN version(*) IP65 Main switch with padlock in ‘0’ position, grey plate and black knob 3 poles 4 poles Part no. Type no. VQ388200 XNA1630BXN VQ404700 XNA3230BXN XNA series Part no. Type no. VQ392400 XNA1640BXN VQ408800 XNA3240BXN Rated operat. current AC21 16 A 32 A BXL version(*) Rated operat. power AC23 15 Kw 22 Kw IP65 Emergency main switch with padlock in ‘0’ position, yellow plate and red knob 3 poles Part no. Type no. VQ387400 XNA1630BXL VQ403900 XNA3230BXL 4 poles Part no. Type no. VQ391600 XNA1640BXL VQ407000 XNA3240BXL (*) An auxiliary contact and a neutral pole may be added. See page 12, accessories: “Auxiliary contacts and additional poles for base mounting” • Dimensions, see page 22 • Circuit diagrams, see page 14 • Technical data, see page 24-25 10 Rated operat. current AC21 16 A 32 A Rated operat. power AC23 15 Kw 22 Kw STANDARD VERSIONS Enclosed XA series BSP version(*) IP55 Switch with grey plate and black knob 3 poles 4 poles Part no. Type no. VC290500 XA0503BSP • VD420700 XA0633BSP VD422300 XA0803BSP VD424900 XA1003BSP (•) Available on request XA series Part no. VC291300 • VD421500 VD423100 VD425600 Type no. XA0504BSP XA0634BSP XA0804BSP XA1004BSP Rated operat. current AC21 50 A 63 A 80 A 100 A BSN version(*) Rated operat. power AC23 18.5 Kw 18.5 Kw 22 Kw 30 Kw IP55 Main switch with padlock in ‘0’ position, grey plate and black knob 3 poles Part no. VD444700 VD446200 • VD448800 VD450400 4 poles Type no. XA0503BSN XA0633BSN XA0803BSN XA1003BSN Part no. VD445400 VD447000 • VD449600 VD451200 Type no. XA0504BSN XA0634BSN XA0804BSN XA1004BSN Rated operat. current AC21 50 A 63 A 80 A 100 A Rated operat. power AC23 18.5 Kw 18.5 Kw 22 Kw 30 Kw (•) Available on request XA series BSL version(*) IP55 Emergency main switch with padlock in ‘0’ position, yellow plate and red knob 3 poles Part no. VD428000 VD430600 VD432200 VD434800 4 poles Type no. XA0503BSL XA0633BSL XA0803BSL XA1003BSL XA series Part no. VD429800 VD431400 VD433000 VD435500 Type no. XA0504BSL XA0634BSL XA0804BSL XA1004BSL Rated operat. current AC21 50 A 63 A 80 A 100 A BCSP/BDSP version Rated operat. power AC23 18.5 Kw 18.5 Kw 22 Kw 30 Kw IP55 Change-over switch or double-ways switch with grey plate and black knob 3 poles Part no. • VI809600 • VI808800 • VI807000 • VI806200 Type no. XA0503BCSP XA0633BCSP XA0503BDSP XA0633BDSP Description Change-over switch 3 poles 1-0-2 Change-over switch 3 poles 1-0-2 Double-ways switch 1-2 Double-ways switch 1-2 Rated operat. current AC21 50 A 63 A 50 A 63 A Rated operat. power AC23 18.5 Kw 18.5 Kw 18.5 Kw 18.5 Kw (•) Available on request • Dimensions, see page 23 • Circuit diagrams, see page 14 • Technical data, see page 24-25 (*) An auxiliary contact and a neutral pole may be added. See page 12, accessories: “Auxiliary contacts and additional poles for base mounting” 11 STANDARD VERSIONS Auxiliary contacts and additional poles for rear mounting XNA - XNF Auxiliary contact 1NC o 1NO PE Accessories Additional pole or auxiliary contact for XNA – XNF series Additional pole Part no. Additional pole Auxiliary contact 1NC o 1NO VC300200 VC301000 VC302800 VC303600 VC304400 Type no. Rating oper. current XC16AN 16 A XC16CN 16 A XC32AN 32 A XC32CN 32 A XC32GN 16-32 A Descrip. 1NO 1NC 1NO 1NC PE PE Max. 2 on each side (XNF series only right side) Auxiliary contact and additional poles for base mounting Accessories XNA - XNF PE Auxiliary contact 1NC o 1NO Additional pole or auxiliary contact for XNA – XNF series Additional pole XNA-XNF 16-32A Part no. XNA-XNF 16-32A Additional pole Auxiliary contact 1NC o 1NO PE Max. 2 on each side (XNF series only right side) VC301000 VC300200 VC303600 VC302800 VC304400 VD459500 VD460300 VD455300 VC298800 VD452000 VD453800 VD454600 Auxiliary contact 1NO XNA 50-63-80-100A Descrip. 1NO 1NC 1NO 1NC PE XNA 50-63-80-100A Part no. Auxiliary contact 1NC Type no. Rating oper. current XC16CN 16 A XC16AN 16 A XC32CN 32 A XC32AN 32 A XC32GN 16-32 A Type no. Rating oper. currento XC012AB 50-63-80-100 A XC012CB 50-63-80-100 A XC100GB 50-63-80-100 A XC050PB 50 A XC063PB 63 A XC080PB 80 A XC100PB 100 A Descrip. 1NO 1NC PE N N N N PE Auxiliary contact 1NO Max. 1 for each side • Dimensions, see page 17 • Technical data, see page 24-25 12 Auxiliary contact 1NC Circuit diagrams of auxiliary contact and additional poles NO Auxiliary contact NC Auxiliary contact 3 1 4 2 PE earth N fourth advanced pole PE N PE N STANDARD VERSIONS Accessories Telescopic shaft extension L = mm ■ Used to adapt switches with base mounting to different mounting depths B-GNAPO min 165 168 180 188 Lam=100 mm max min 215 218 230 238 215 218 230 238 max min 265 268 280 288 265 268 280 288 max min 315 318 330 338 565 568 580 588 max 615 618 630 638 B-GNAP1 Lam=150 mm B-GNAP2 Lam=200 mm 5 B-GNAPO B-GNAP1 B-GNAP2 B-GNAP4 Metal shaft depth (Lam) 100 mm 150 mm 200 mm 500 mm 7,3 VQ447600 VQ448400 VQ449200 ZN869700 Type no. Quota L per numero di elementi L Part no. B-GNAP4 Lam=500 mm Modular shaft extension 4 max ■ Used to adapt switches with base mounting to different mounting depths ■ The pack contains 4 modules L = mm KNZ XNA-XNF XNA XNA 3/4PC BC (16÷40) (16÷32) (50÷100) (50÷100) Quota L per numero di elementi 3 1 2 L Part no. Type no. VQ446800 B-GNAMO KNZ XNA-XNF XNA XNA 3/4P BC (16÷40) (16÷32) (50÷100) (50÷100) 1 min 101 103 115 123 max min 111 113 125 133 126 128 140 148 max min 136 138 150 158 151 153 165 173 max min 161 163 175 183 176 178 190 198 max 186 188 200 208 2 Max. 4 modules B-GNAMO 5 7,3 3 4 Base fixing plate Part no. Type no. VC218600 B-KG6047 Terminal covers Used to raise the level of protection for the connector terminals For series: KNZ (16÷40 A) Part no. Type no. Description VC211100 B-G1280 3 or 4 poles * the code includes the upper and lower protection For series: XNA (50÷100 A) Part no. Type no. Description VD456100 B-G1305 3 poles * the code includes the upper and lower protection For series: XNA-XNF (16÷32 A) Part no. Type no. Description VC286300 B-G813 3 or 4 poles * the code includes the upper and lower protection For series: XNA (50÷100 A) Part no. Type no. Description VD457900 B-G1304 additional pole * the code includes the upper and lower protection 13 CIRCUIT DIAGRAMS Connection diagrams Type Diagram L1 L2 L3 KNZ XNA Switchdisconnectors 3 poles T1 T2 T3 Type Diagram L1 L2 L3 N KNZ XNA Switchdisconnectors 4 poles T1 T2 T3 N Type Diagram XNA (50-63 80-100 A) Change-over Double-ways 3 or 4 poles 1/L1 T1 14 T4 5/L3 3/L2 T2 T5 T3 T6 N N N DIMENSIONS (mm) Rear mounting Type Front view Side view 55,5 53 9 KNZ...R (16-30-40 A) 47 KNZ...G (16-30-40 A) 70 53 9 67,5 XNA...R (16-32 A) XNA...G (16-32 A) Base mounting Type Front view Side view 5 KZN...B (16-30-40 A) 47 DIN 46277/3 55,5 7,3 DIN 4627/3 6,5 with B-KG6047 76 70 67,5 DIN 46277/3 28,5 XNA...B (16-32 A) 67,5 4,2 7,3 5 64,5 78 15 DIMENSIONS (mm) Base mounting Type Front view Side view 90 60 5 L3 2 T1 4 T2 6 T3 5,2 68 3 L2 DIN 46277/3 1 L1 80 XNA...B (50-63-80 100 A) 90 7,3 23,5 25 6,5 70 64,5 78 28,5 DIN 46277/3 4,2 7,3 99,5 XNF...B (16 A) 72,5 5 70 64,5 78 28,5 DIN 46277/3 4,2 7,3 65 121,5 XNF...B (32 A) 56,5 75,5 120.5 (3 Pole) - 164.5 (4 Pole) XNA ... BC (50-63-80 100 A) 16 5 DIMENSIONS (mm) Handle devices Type Front view Side view Drilling template front mounting Drilling template Base mounting 37 32 32 19 32 48 YNUT4 YNUY4 28 (*) 10 48 3,7 3,7 (*) in alternative to 32 67 19 38 36 38 36 67 YNUT6 YNUY6 YNUT6C 39 3,7 28 (*) 10 32 67 32 67 19 32 YNUK6 YNUL6 YNUK6C YNUL6C 3,7 39 3,7 (*) in alternative to 32 Accessories Type 40 15 Front view XC100GB XC050PB XC063PB XC080PB XC100PB Side view 22 68 52 XC32GN XC012CB XC012AB XC16AN XC32AN XC16CN XC32CN Side view 48,5 Front view 67,5 Type 43,5 60 B-KG6047 M4 45 22 17 DIMENSIONS (mm) Handle devices Type Front view 48 37 39 3,2 max 67 24,1 max 67 YNGT6 YNGY6 Drilling template 48 YNGT4 YNGY4 Side view 22,5 max YNGK6 YNGL6 39 67 67 Assembly system body-handle device Rear mounting Ø22 mm 18 DIMENSIONS (mm) Base mounting – bodies/handle devices Type Front view Side view 5 L 37÷39 55,5 A A 48 67 YNUT4 - YNUY4 YNUT6 - YNUY6 DIN 46277/3 Bodies KNZ...B (16-30-40 A) + handle devices YNUT4 - YNUY4 YNUT6 - YNUY6 Dimensions 7,3 1÷4 76 150 Min 76 Max 86 Dimensions L To adapt the switches with base mounting to the various assembly depths, see page 13 5 Bodies KNZ...B (16-30-40 A) + handle devices YNUK6 - YNUL6 39 DIN 46277/3 67 L 76 Max 86 Dimensions L 67 Min 7,3 1÷4 76 150 To adapt the switches with base mounting to the various assembly depths, see page 13 28,5 67,5 4,2 5 1÷4 78 150 64,5 A 48 67 YNUT4 - YNUY4 YNUT6 - YNUY6 DIN 46277/3 70 A 37÷39 L 7,3 Bodies XNA...B (16-32 A) + handle devices YNUT4 - YNUY4 YNUT6 - YNUY6 Min 78 Max 88 Dimensions L To adapt the switches with base mounting to the various assembly depths, see page 13 67 Min 78 Max 88 Dimensions L 67 Bodies XNA...B (16-32 A) + handle devices YNUK6 - YNUL6 39 L DIN 46277/3 7,3 5 78 1÷4 150 To adapt the switches with base mounting to the various assembly depths, see page 13 19 DIMENSIONS (mm) Base mounting – Bodies/handle devices Type Front view Side view 7,3 DIN 46277/3 39 Min 90 Max 100 L 5,2 Dimensions 1÷4 23,5 25 6,5 150 90 7,3 To adapt the switches with base mounting to the various assembly depths, see page 13 L 39 67 80 Min 90 Max 100 Dimensions L 5,2 90 DIN 46277/3 67 60 Bodies XNA...B (50-63-80 100 A) + handle devices YNUK6 - YNUL6 L 67 80 Bodies XNA...B (50-63-80 100 A) + handle devices YNUT6 - YNUY6 90 67 60 Dimensions 1÷4 23,5 25 e 6,5 150 90 To adapt the switches with base mounting to the various assembly depths, see page 13 e Bodies XNA...BC + handle devices YNUT6C Min 97.5 Max 107.5 Dimensions L To adapt the switches with base mounting to the various assembly depths, see page 13 e Bodies XNA...BC + handle devices YNUK6C o YNUL6C e Min 97.5 Max 107.5 Dimensions L To adapt the switches with base mounting to the various assembly depths, see page 13 20 DIMENSIONS (mm) Base mounting – Bodies/Handle devices Type Front view Side view 70 64,5 A DIN 46277/3 28,5 4,2 5 78 Max 88 Dimensions L 37÷39 L A 48 67 78 Max 88 Dimensions L To adapt the switches with base mounting to the various assembly depths, see page 13 78 39 L DIN 46277/3 7,3 Min 150 65 70 67 Min YNUT4 - YNUY4 YNUT6 - YNUY6 5 67 L To adapt the switches with base mounting to the various assembly depths, see page 13 24 56,5 63,5 75,5 28,5 Dimensions 150 DIN 46277/3 28,5 4,2 4,2 88 39 78 7,3 4,2 Max DIN 46277/3 67 28,5 4,2 4,2 L 1÷4 4,2 78 To adapt the switches with base mounting to the various assembly depths, see page 13 1÷4 70 64,5 A 65 1÷4 150 Min 78 Max 88 Dimensions L 24 Bodies XNF...B (32 A) + handle devices YNUK6 - YNUL6 Min 150 78 7,3 58 72,5 Bodies XNF...B (32 A) + handle devices YNUT4 - YNUY4 YNUT6 - YNUY6 YNUT4 - YNUY4 YNUT6 - YNUY6 5 70 67 A 48 67 37÷39 1÷4 58 72,5 Bodies XNF...B (16 A) + handle devices YNUK6 - YNUL6 L 7,3 4,2 Bodies XNF...B (16 A) + handle devices YNUT4 - YNUY4 YNUT6 - YNUY6 Dimensions 56,5 63,5 75,5 5 78 To adapt the switches with base mounting to the various assembly depths, see page 13 21 DIMENSIONS (mm) Enclosed Type Front view Side view 78 37-39 80 98 KNZ BYP (16-32-40 A) 125 4.5 110 Drilling template N°4 ø Pg 16 - M20 78 80 98 125 KNZ BYL/BYN (16-32-40 A) 37-39 4.5 110 N°4 ø Pg 16 - M20 140 97 115 142 142 165 XNA Type BXP (16-32 A) 115 6,5 60 140 97 XNA Type BXL/BXN (16-32 A) 22 165 6,5 60 DIMENSIONS (mm) Enclosed Type Front view Side view 150 100 Drilling template 30 N° 4 Ø Pg 29 - M40 150 185 N° 8 Ø Pg 21 - M25 220 6,5 XA Type BSP/BSG (50-63-80 100 A) 115 100 30 N° 4 Ø Pg 29 - M40 190 185 N° 4 Ø Pg 21 - M25 220 6,5 XA Type BSL/BSN (50-63-80 100 A) 115 125 30 N° 4 Ø Pg 29 - M40 205,4 6,5 2 N° 8 Ø Pg 21 - M25 1 240 XA Type BCSP/BDSP (50-63 A) 155,4 23 TECHNICAL DATA Conformity to standards IEC 947-1 EN 60947-1 Rated insulation voltage Rated operating voltage Rated impulse withstand voltage Rated thermal current open enclosed Rated operation frequency Power dissipation for each pole Rated operating current Ie in category AC-21A Switching resistive loads with light overloads AC-22A Switching mixed resistive and inductive loads with light overloads Rated operating power AC-23A Periodic switching of motors and interruption while running AC-3 Starting of cage motors and interruption while running Ui Ue Uimp Ith Ithe V V kW A A Hz W KNZ16 690 690 6 25 25 50 1 KNZ30 690 690 6 32 32 50 1.1 KNZ40 690 690 6 40 40 50 1.6 3 phases – 3 poles + neutral 3 phases – 3 poles + neutral 690V 690V A A 20 16 30 32 40 32 3 phases – 3 poles 230V 400V 500V 690V 230V 400V 500V 690V 230V 400V A/kW A/kW A/kW A/kW A/kW A/kW A/kW A/kW A A 22/5.5 18/8 14/9 14/11 16/4 18/7.5 12/7.5 10/9 184 160 24/7.5 20/12 16/11 16/15 17/6 15/9.5 14/9.5 12/11.5 248 264 31/10 33/18.5 32/22 23/22 27/9 27/17 28/19 24/22 Icw Icm A A kA A 600 1500 10 16 600 1500 10 16 800 2000 10 32 Cycles 106 Nm 2 B6 1.5-10 1.5-16 M4 1.4 2 B6 1.5-10 1.5-16 M4 1.4 2 B6 1.5-10 1.5-16 M4 1.4 600Vac A 25 30 30 120V 240V 120V 240V 480V 600V HP/FLA HP/FLA HP/FLA HP/FLA HP/FLA HP/FLA -/-/2/5/7.5/7.5/- 2/24 3/17 3/19.2 7.5/12 10/14 10/11 3/5/5/7.5/22 10/14 10/11 AWG AWG lb.in. 16-8 16-6 12 16-8 16-6 12 16-8 16-6 12 3 phases – 3 poles Rated breaking capacity in category AC-23A (Cosϕ 0,45) Short-circuit safety Rated short time with stand current (1s) Rated short-circuit make capacity Rated conditional short-circuit current With fuses class gG Mechanical data Mechanical life (120 cycles/hour) Connection according to IEC 947-1 and EN 60947-1 Connecting capacity stranded wires plus connector solid wires Connection terminal screw dimensions Screw tightening torque 500V Min-Max Min-Max Technical data UL/CSA General Use current Rated operating power 1 phase - 2 poles 3 phases - 3 poles Mechanical data Connecting capacity stranded wires plus connector solid wires Screw tightening torque mm2 mm2 Protection degree according to IEC 529 EN 60529 Body Handle devices Normal service conditions Ambient temperature operative storage Weather resistance, according to IEC 68 part: 24 IP20 IP65 °C °C constant hot-damp climate cyclic hot-damp climate -25 +55 -30 +70 2-8 2-30 TECHNICAL DATA Conformity to standards IEC 947-3 EN 60947-3 Rated insulation voltage Rated operating voltage Rated impulse withstand voltage Rated thermal current open enclosed Rated operation frequency Power dissipation for each pole Rated operating current Ie in category AC-21A Switching resistive loads with light overloads 3 phases – 3 poles + neutral AC-22A Switching mixed resistive and inductive loads with light overload 3 phases – 3 poles + neutral Rated operating power AC-23A Periodic switching of motors and interruption while running 3 phases – 3 poles AC-3 Starting of cage motors and interruption while running 3 phases – 3 poles Rated breaking capacity in category AC-23A (Cosϕ 0,45) Short-circuit safety Rated short time with stand current (1s) Rated short-circuit make capacity Rated conditional short-circuit current With fuses class gG Mechanical data Mechanical life (120 cycles/hour) Connection according to IEC 947-1 and EN 60947-1 Connecting capacity stranded wires plus connector solid wires Connection terminal screw dimensions Screw tightening torque Technical data UL/CSA General Use current Rated operating power 1 phase - 2 poles 3 phases - 3 poles Mechanical data Connecting capacity Ui Ue Uimp Ith Ithe V V kW A A Hz W XNA16 690 690 6 25 16 50 0.9 690V 690V A A 20 16 40 32 230V 400V 500V 690V 230V 400V 500V 690V 230V 400V A/kW A/kW A/kW A/kW A/kW A/kW A/kW A/kW A A 7.5 13 13 15 6 10 10 12 184 192 33/10 33/18.5 32/18.5 28/22 27/15 27/15 27/15 23/18.5 256 264 Icw Icm A A kA A 400 1500 10 16 800 2000 10 32 1500 2000 15 63 1500 2000 15 63 1500 2500 15 80 Cycles 106 Nm 2 B6 1.5-10 1.5-16 M4 1.4 2 B6 1.5-10 1.5-16 M4 1.4 0.1 B9 6-35 10-50 M5 2.8 0.1 B9 6-35 10-50 M5 2.8 600Vac A 20 40 80 120V 240V 120V 240V 480V 600V HP/FLA HP/FLA HP/FLA HP/FLA HP/FLA HP/FLA 1.5 2 2 5 10 10 3/34 5/28 5/30.5 10/28 15/27 15/27 3/34 5/28 10/32 (*) 20/54 25/34 30/32 AWG AWG lb.in. 16-8 16-6 12 16-8 16-6 12 500V Min-Max Min-Max stranded wires plus connector solid wires Screw tightening torque mm2 mm2 XNA32 XNA050 XNA063 XNA080 XNA100 XNF16 690 690 690 690 690 690 690 690 690 690 690 690 6 6 6 6 6 6 40 50 63 80 100 16 32 50 63 80 80 16 50 50 50 50 50 50 1.6 1.8 (**) 50 50 Weather resistance, according to IEC 68 part: 100 100 16 16 32 32 24/7.5 24/13 16/13 16/15 19/16 18/10 14/10 13/2 192 240 33/10 33/18.5 32/18.5 23/22 28/9 27/15 27/15 23/18.5 256 330 1500 2500 15 100 400 800 10 16 10 32 0.1 B9 6-35 10-50 M5 2.8 0.1 B9 6-35 10-50 M5 2.8 2 B6 1.5-10 1.5-16 M4 1.4 2 B6 1.5-10 1.5-16 M4 1.4 100 100 10-1 8-1 24 10-1 8-1 24 5/56 5/56 7.5/40 10/40 15/48 (*) 20/62 (*) 20/54 25/68 40/52 50/65 50/52 50/52 10-1 8-1 24 10-1 8-1 24 IP20 IP65 operative storage constant hot-damp climate cyclic hot-damp climate °C °C Conformity to standards IEC 947-3-5 EN 60947-3-5 Auxiliary contacts Rated insulation voltage Rated thermal current open AC-21A Switching resistive loads with light overloads AC-15 Electromagnetic loads in AC 80 80 40/11 47/15 58/18.5 70/22 40/22 47/25 54/30 63/35 32/22 43/30 54/37 65/45 19/18.5 19/18.5 24/22 31/30 35/11 35/11 17/45 58/18.5 18.5/33 33/18.5 43/22 54/30 28/18.5 32/22 43/30 53/37 16/15 16/15 19/10.5 23/22 320 376 464 560 320 376 432 504 Protection degree according to IEC 529 EN 60529 Body Handle devices Normal service conditions Ambient temperature 63 63 XNF32 690 690 6 32 32 50 3.5 (**) Ui Ith 690V 230V Type no. XC16AN XC32AN Type no. XC16CN XC32CN V 690 690 A 20 40 A 6 6 A 20 40 -25 +55 -30 +70 2-8 2-30 XC012AB XC012CB 690 12 6 XC16AN XC32AN XC16CN XC32CN 690 690 20 40 6 6 20 40 (**) for each single fuse (*) test at 200V 25 APPROVALS XNF SERIES XNA SERIES KNZ SERIES SERIES 26 i C ® US KNZ16 ✔ ✔ KNZ30 ✔ ✔ KNZ40 ✔ ✔ ✔ XNA016 ✔ ✔ ✔ XNA032 ✔ ✔ ✔ XNA050 ✔ ✔ ✔ ✔ XNA063 ✔ ✔ ✔ ✔ XNA080 ✔ ✔ ✔ ✔ XNA100 ✔ ✔ ✔ ✔ XNF16 ✔ ✔ XNF32 ✔ ✔ TECHNICAL INFORMATION - STANDARDS BREMAS switchgears and controlgears are designed, manufactured and tested in accordance with the requirements laid down in the most important national and international specifications and standards. In most countries, the use of electrical devices is permitted if the manufacturer, upon his own responsibility, guarantees the conformity to the requirements. In other countries, the law lays down compulsory approval procedures. For better understanding of the subject, the information set out below deals with REQUIREMENT, CONFORMITY, APPROVAL. REQUIREMENTS This refers to the definitions contained in a standard relating to normal operating conditions, performance requirements, test procedures, etc. Requirements can be subdivided into: QUALITY MARK This is a special form of approval adopted for equipment for household use. The best known Authorities are: IMQ Istituto Marchio di Qualità, Italy KEMA-KEUR Keuring van Elektrotechnische Materialen, The Netherlands MARINE CLASSIFICATION This is a special form of approval adopted for equipment installed on board of ships. The best known Authorities are: RINA Registro Italiano Navale, Italy LROS Lloyd’s Register of Shipping, Great Britain BV Bureau Veritas, France Internationals requirements These are the requirements issued by the following Authorities: IEC International Electrotechnical Commission This international commission, with members from all the major industrialised countries, issues recommendations that are taken up as the basis of the single national standards. CENELEC Comité Européen de Normalisation Electrotechnique This committee issues the EN standards for the European countries. National Requirements For example, the requirements issued by the following Authorities: CEI Comitato Elettrotecnico Italiano, Italy VDE Verband Deutscher Elektrotechniker, Germany NF Normes Françaises, France CSA Canadian Standards Association, Canada UL Underwriter’s Laboratories, United States of America CONFORMITY Conformity to a standard consists of a declaration made by the manufacturer under his own responsibility to the effect that a specific product comply with all the requirements of the relevant standard. Recently, the CE Mark has been introduced, for which the manufacturer declares that the products comply with the EEC applicable Directives. For the electrical material the EEC applicable Directives are: LOW VOLTAGE Directive (72/23/EEC, modified to 93/68/EEC) for the safety of electric products and E.M.C. Directive (89/339/EEC, modified to 92/31/EEC and to 93/68/EEC) and Electromagnetic Compatibility. APPROVAL IIn some countries, approval of electric materials is compulsory by law. This consists of a certificate of conformity with the requirements issued not by the manufacturer, but by an independent Testing Laboratory legally recognized. Each approved item has to carry the mark of approval, such as CSA or UL. For this last, two different levels of acceptance are required: RECOGNIZED = The device should be marked with the letters UR only, and can be used in electrical equipment only by qualified personnel who are fully aware of the limits of use of the product. The sale of this equipment for general use is not permitted. LISTED = The device should be marked with the letters UL alongside the mark of approval and can be fitted in electrical appliances or sold loose, as it complies with all the requirements in the relevant standard. 27 TECHNICAL INFORMATION - DEFINITIONS Utilization category The standards define a certain number of categories with regard to the normal applications of contactors. Each category defines the current and the voltage values (expressed as multiples of the rated values) that corresponds to the connection and the switching of the load. Operating cycle A succession of operations from one position to another and back to the first position through all other positions, if any. Main circuit All the conductive parts of a switching device included in the circuit which it is designed to close or open Control circuit All the conductive parts (other than the main circuit) of a switching device which are included in a circuit used for the closing operation or opening operation, or both, of the device. Auxiliary circuit All the conductive parts of a switching device which are intended to be included in a circuit other than the main circuit and the control circuits of the device. Rated operational current Ie Current which takes into account the rated voltage, the rated frequency, the rated duty, the utilization category. Rated thermal current Ith The maximum current that a switching device can carry on eight-hour duty, without the temperature rise of its several parts exceeding the limits specified. Short-time withstand current The current that a switching device can withstand in the closed position during a specified short time, under prescribed conditions of use and behaviour. Time constant or Power factor The ratio between the inductance and resistance, that is L/R = mH/Ω=ms Clearance The distance between two conductive parts, along a string stretched the shortest way between these conductive parts Creepage distance The shortest distance along the surface of an insulating material between two conductive parts. Electrical durability It is defined as the number of on-load operating cycles which will be attained or exceeded by 90% of all devices tested without repair or replacement of any part. Mechanical durability It is defined as the number of no-load operating cycles which will be attained or exceeded by 90% of all devices tested without repair or replacement of any part. Pole impedance This is the complex resistance of a pole at rated current. Breaking or making capacity A value of prospective breaking or making current that a switching device is capable of breaking or making at the stated voltage under prescribed condition of use and behaviour. 28 Intermittent duty A duty with on-load periods, in which the main contacts of the equipment remain closed, having a definite relation to off-load periods, both periods being short to allow the equipment to reach thermal equilibrium. Intermittence ratio (I.R.) or operation factor (m) It represents the ratio between “t” duration of the current flow and “T” total operating cycle time, that is I.R. or m=t/T. Often this ratio is expressed as a percentage. For total operating cycle time, it is understood the time elapsing between the beginning of two consecutive passings of current. Opening time The interval of time between the specified instant of initiation of the opening operation and the instant when the arcing contacts have separated in all poles. Closing time The interval of time between the initiation of the closing operation and the instant when the contacts touch in all poles. Air ambient temperature It is the temperature, determined under prescribed conditions, of the air surrounding the complete switching device. For devices installed inside an enclosure, it is the temperature of the air outside the enclosure. Rated operational voltage Ue A value of voltage which, combined with a rated operational current, determines the application of the equipment and to which the elevant tests and the utilization categories are referred. Rated insulation voltage Ui The value of voltage to which dielectric tests and creepage distances are referred. TECHNICAL INFORMATION - UTILIZATION CATEGORIES Utilization with alternating current Utilization with direct current Power equipment , switchgear and controlgear according to EN 60947-4 and IEC 947-4 (contactors, equipment for starting of motors) Power equipment, switchgear and controlgear according to EN 60947-4 and IEC 947-4 (contactors, equipment for starting of motors) AC1 Connection or disconnection of non-inductive or slightly inductive loads (e.g. resistance furnaces). This equipment should have a cos no less than 0,95 DC1 AC2 Starting, counter-current braking and switching off of slip-ring motors. The contactor makes and breaks the starting current, which can reach 1,5 ÷ 3 times the rated current of the motor. DC3 AC3 Starting and switching off of squirrel-cage motors during running. The contactor makes the starting current, which can reach 4 ÷ 8 times the rated current of the motor, and breaks the rated current absorbed by the motor. The switching conditions are easy, as the voltage at the motor terminals is approximately 20 ÷ 30% of the supply voltage. Starting, plugging and inching of squirrel-cage motors. The contactor makes and breaks the starting current, which can reach 4 ÷ 88 times the rated current of the motor. The switching conditions are severe, as the voltage at the motor terminals can be equal to that of the supply voltage. Switching of electric discharge lamp controls. Switching of incandescent lamps. The peaks of current at the connection of the lighting circuits and the power factor are function of the type of lamp, the wiring system and the presence or not of the compensation. Switching of transformers. High peaks of current characterize the commutation of transformers during the connection phase, due to the phenomenon of magnetization. Switching of capacitor banks. High peaks of current characterize the commutation of capacitor banks during the connection phase, due to the presence of harmonic currents. AC4 AC5a AC5b AC6a AC6b DC5 DC6 Connection or disconnection of non-inductive or slightly inductive loads (e.g. resistance furnaces). This equipment should operate with a L/R time-constant less than or equal to 1ms. Starting, plugging and inching of shunt-motors. Dynamic breaking of DC motors. This equipment should operate with a L/R time-constant less than or equal to 2,5ms. The contactor makes and breaks the starting current, which is close to 2,5 times the rated current of the motor. The switching conditions are severe, as the voltage at the motor terminals can be equal to that of the supply voltage. Starting, plugging and inching of series-motors. Dynamic breaking of DC motors. This equipment should operate with a L/R time-constant less than or equal to 15ms. The contactor makes and breaks the starting current, which is close to 2,5 times the rated current of the motor. The switching conditions are severe, as the voltage at the motor terminals can be equal to that of the supply voltage. Switching of incandescent lamps. Power equipment, switchgear and controlgear according to EN 60947-3 and IEC 947-3 (switches, disconnectors, switch-disconnectors, fuse-combination units) DC20 Connecting and disconnecting under no-load conditions. DC21 Switching of resistive loads including moderate overloads. DC22 Switching of mixed resistive and inductive loads, including moderate overloads (e.g. shunt-motors). DC23 Switching of highly inductive loads (e.g. series-motors). Power equipment, switchgear and controlgear according to EN 60947-3 and IEC 947-3 (switches, disconnectors, switch-disconnectors, fuse-combination units) Control circuit devices and switching elements according to EN 60947-5 and IEC 947-5 (control relays, auxiliary contacts, units for control and signalling) AC20 Connecting and disconnecting under no-load conditions. AC21 Switching of resistive loads including moderate overloads. AC22 Switching of mixed resistive and inductive loads, including moderate overloads. DC12 Control of resistive loads and solid state loads with isolation by optocouplers. DC13 Control of electromagnets without economy resistor in circuit. DC14 Control of electromagnetic loads having economy resistor in circuit. AC23 Switching of motor loads or other highly inductive loads. Control circuit devices and switching elements according to EN 60947-5 and IEC 947-5 (control relays, auxiliary contacts, units for control and signalling) AC12 Control of resistive loads and solid-state loads with isolation by optocouplers. AC13 Control of solid state loads with transformer isolation. AC14 Control of small electromagnetic loads ( ≤ 72VA). AC15 Control of electromagnetic loads ( > 72VA). - By plugging is understood stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running. - By inching (jogging) is understood energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism. - The designation of AC20-AC21-AC22-AC23-DC20-DC21-DC22-DC23 utilization categories is completed by the suffix A or B according to wheter the intended applications require frequent or infrequent operations. Utilization categories with suffix B are appropriate for devices which, due to design or application, are only intended for infrequent operation (e.g. disconnectors normally only operated to provide isolation for maintenance work). 29 TECHNICAL INFORMATION - CABLE DIMENSIONS TABLE Standard cross-sections of round copper conductors corresponding to the conventional thermal currents Range of rated thermal current ■ A 0 8 8 12 12 15 15 20 20 25 25 32 32 50 50 65 65 85 85 100 100 115 115 130 130 150 150 175 175 200 200 225 225 250 250 275 275 300 300 350 350 400 400 500 500 630 630 800 Range of rated thermal current ■ A 400 500 500 630 630 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 2500 3150 Section of2 copper conductors / cables mm AWG/MCM 1 18 1,5 16 2,5 14 2,5 12 4 10 6 10 10 8 16 6 25 4 35 3 35 2 50 1 50 0 70 00 95 000 95 0000 120 250 150 300 185 350 185 400 240 500 2x150 2x250 2x185 2x350 2x240 2x300 Section of copper bars ▲ N° mm inch 2 30x5 1.00x0.250 2 40x5 1.25x0.250 2 50x5 1.50x0.250 2 60x5 2.00x0.250 2 80x5 2.50x0.250 2 100x5 3.00x0.250 3 100x5 3.00x0.250 4 100x5 3.00x0.250 3 100x10 6.00x0.250 ■ The current value should always be greater than the left-hand value and less than or equal to the right-hand value. ▲ Bars are assumed to be arranged with their long faces vertical. Arrangements with long faces horizontal may be used if specified by the manufacturer. Where 4 bars are used they shall be in two sets of two bars with not more than 100mm between pair centres. 30 TECHNICAL INFORMATION - PROTECTION DEGREES The International Recommendations IEC 529 to which the single national standards refer, as well as the European Harmonized Standards EN 60529 and EN 50102, classify the degree of protection provided by the enclosures for electrical equipment as regards: a) protection of the persons against access to hazardous parts inside the enclosure (e.g. low-voltage live parts, mechanical parts). b) protection of the equipment inside the enclosure against ingress of solid foreign objects. c) protection of the equipment inside the enclosure against the harmful effects due to the ingress of water. d) protection of the enclosure against damage due to harmful external mechanical impacts. The degrees of protection relating to the first three items are designed by the IP part no, followed by a combination of two characteristic numerals, to which a first additional letter and a second supplementary letter, both optional, can be added. IP Part no First characteristic numeral Second characteristic numeral Protection against ingress of solid objects. Protection against harmful ingress of water Protection of persons against access to hazardous parts. 0 No protection. 1 Full penetration of 50 mm diameter sphere not allowed. Protection against access with the back of a hand. IK Part no Characteristic group numeral Protection against harmful external mechanical impacts. 0 No protection. 1 Protection against vertically falling drops of water. Limited ingress permitted. 01 2 Full penetration of 12,5 mm diameter sphere not allowed. Protection against access with a finger. 2 Protected against vertically falling drops of water with enclosure tilted 15° from the vertical. Limited ingress permitted. Dripping up to 15° from the vertical. 02 3 The access probe of 2,5 mm diameter shall not penetrate. Protection against access with a tool. 3 Protected against sprays to 60° from the vertical. Limited ingress permitted. Limited spraying. 03 4 The access probe of 1,0 mm diameter shall not penetrate. Protection against 4 Protected against water splashed from all directions. Limited ingress permitted. Splashing from all directions. 04 5 Limited ingress of dust permitted (no harmful deposit). Protection against access with a wire. 5 Protected against jets of water. Limited ingress permitted. Hosing jets from all directions. 05 6 Total protection against ingress of dust. Protection against access with a wire. 6 Protected against strong jets of water. Limited ingress permitted. Strong hosing jets from all directions. 06 Protected against the effects of immersion between 15 cm and 1 m. Temporary immersion. 07 Protected against long periods of immersion under pressure. Continuous immersion 08 29,5 cm 09 20 cm 10 40 cm 15 cm mini ↕ 7 1m m 8 0 No protection. Resistance to impact of a mass of 200 g with a striking energy of 0,15 J. 20 0g 7,5 cm Resistance to impact of a mass of 200 g with a striking energy of 0,20 J. 20 0g 10 cm 20 Resistance to impact of a mass of 200 g with a striking energy of 0,35 J. 20 Resistance to impact of a mass of 200 g with a striking energy of 0,50 J. 20 0g Resistance to impact of a mass of 200 g with a striking energy of 0,70 J. 50 Resistance to impact of a mass of 500 g with a striking energy of 1 J. 0g 17,5 cm 0g 25 cm 25 cm 0g 20 cm 50 0g Resistance to impact of a mass of 500 g with a striking energy of 2 J. 40 cm 1,7 kg 5k g 5k g When the equipment is classified for one of the two main types of protection only, that is to say with only one numeral, the omitted numeral should be replaced with the letter X (e.g. IPX5 or IP2X). Resistance to impact of a mass of 1,7 kg with a striking energy of 5 J. Resistance to impact of a mass of 5 kg with a striking energy of 10 J. Resistance to impact of a mass of 5 kg with a striking energy of 20 J. 31 TECHNICAL INFORMATION - RATED MOTOR CURRENTS 3-phases motors Single-phase motors Rated current of the motor and the recommended aM fuses Rated current Potenza Power 220-230 V 380-400 V 415 V 440 V 500 V 220 / 230 V kW CV motor A aM A motor A aM A motor A aM A motor A aM A motor A aM A 0,37 0,55 0,75 1,1 1,5 2,2 3 3,7 4 5,5 7,5 9 10 11 13 15 18,5 22 25 30 33 37 40 45 51 55 59 63 75 80 85 90 100 110 129 132 140 147 150 160 180 185 200 220 280 295 300 335 355 0,5 0,75 1 1.5 2 3 4 5 5,5 7,5 10 12 13,5 15 17,5 20 25 30 35 40 45 50 54 60 70 75 80 85 100 110 115 125 136 150 175 180 190 200 205 220 245 250 270 300 380 400 410 450 480 1,8 2,75 3,5 4,4 6,1 8,7 11,5 13,5 14,5 20 27 32 35 39 45 52 64 75 85 103 113 126 134 150 170 182 195 203 240 260 280 295 325 356 420 425 450 472 483 520 578 595 626 700 900 950 980 1100 1150 2 4 4 6 8 10 12 16 16 20 32 32 40 40 50 63 63 80 100 125 125 160 160 160 200 200 200 250 250 315 315 315 400 400 500 500 500 500 500 630 630 630 630 800 1000 1000 1000 1200 1200 1,03 1,6 2 2,6 3,5 5 6,6 7,7 8,5 11,5 15,5 18,5 20 22 26 30 37 44 52 60 68 72 79 85 98 105 112 117 138 147 156 170 188 205 242 245 260 273 280 300 333 342 370 408 510 550 565 620 636 2 2 2 4 4 6 8 8 10 12 16 20 20 25 32 32 40 50 63 63 80 80 80 100 100 125 125 125 160 160 160 200 200 250 250 250 315 315 315 315 400 400 400 500 630 630 630 630 800 1 1,5 2 2.5 3,5 5 6,5 7,5 8,4 11 14 17 19 21 25 28 35 40 47 55 60 66 71 80 90 100 105 115 135 138 147 165 182 200 230 240 250 260 270 280 320 325 340 385 475 500 510 550 580 2 2 2 4 4 6 8 8 10 12 16 20 20 25 25 32 40 40 50 63 63 80 80 80 100 100 125 125 160 160 160 200 200 200 250 250 250 315 315 315 400 400 400 400 500 500 630 630 630 1 1,36 1,68 2,37 3,06 4,42 5,77 7,1 7,9 10,4 13,7 16,9 18,5 20,1 21,9 26,5 32,8 39 45,3 51,5 58 64 67 76 83 90 97 109 125 131 139 146 162 178 209 215 227 236 246 256 289 295 321 353 448 473 483 518 549 2 2 2 4 4 6 8 8 8 12 20 20 20 25 25 32 40 40 50 63 63 80 80 80 100 100 100 125 125 160 160 160 200 200 250 250 250 250 250 315 315 315 400 400 500 500 500 630 630 1 1,21 1,5 2 2,6 3,8 5 5,9 6,5 9 12 13,9 15 18,4 20,5 23 28,5 33 39,4 45 50 55 60 65 75 80 85 89 105 112 118 129 143 156 184 187 200 207 210 220 254 263 281 310 400 416 420 472 500 2 2 2 2 4 4 6 6 8 10 12 20 20 20 25 25 32 40 40 50 63 63 63 80 80 80 100 100 125 125 125 160 160 160 200 200 200 250 250 250 315 315 315 315 400 500 500 500 500 kW CV motor A aM A 0,07 0,1 0,12 0,18 0,25 0,37 0,55 0,75 1,1 1,5 1,8 2,2 3 4 4,4 5,2 5,5 6 7 7,5 1/12 1/8 1/6 1/4 1/3 0,5 0,75 1 1,5 2 2,5 3 4 5 6 7 7,5 8 9 10 1,2 1,6 1,9 2,3 2,9 3,9 5,2 6,6 9,6 12,7 15,7 18,6 24,3 29,6 34,7 39,8 42,5 44,5 49,5 54,4 2 2 2 4 4 4 6 6 10 16 16 20 25 32 40 40 50 50 50 63 Notes The table contains the value of the current absorbed by the motor and the corresponding aM fuse for protection against short-circuit. The current values indicated refer to those absorbed at full load by 3-phase squirrel-cage motors, 4 pole, 1500 rpm, 50 Hz, and by single-phase motors. These values are approximate, as they can slightly change according to the type of motor and the manufacturer. The thermal overload relay should therefore be adjusted for the current indicated on the motor nameplate and the rating of the fuse should be in proportion to this value,if different from that given in the table. 32 TECHNICAL INFORMATION - CO-ORDINATION WITH SHORT-CIRCUIT PROTECTIVE DEVICE When a disconnector, a contactor, a thermal overload relay, an automatic circuit breaker or a set of three fuses are chosen to realizes a plant, the problem of their mutual behaviour arises, that is to say their “co-ordination” on the basis of the electrical function carried out by each device. Symbol Device Function Notes Switch Control It makes, carries and switches the currents up to its making and breaking capacity. Being a device characterised usually by a limited breaking capacity, it is not able to switch high over-currents as those of short-circuit. Thermal overload relay Protection against overcurrent and phase failure It protects against thermal overloads included between 1,2 and times the rated current of the load (up to locked rotor condition, case of motors). This relay is characterised by a precise limit, represented by the max specific passing energy, beyond which an alteration of its tripping characteristic may occurs and, as an extreme case, the fusion of the heater elements. In fact, the thermal overload relay points out only the overload condition, delegating the real protection to the contactor, which switches the circuit. Fuses Protection against short-circuits They have not to trip in presence of a normal current overload. In order to avoid the fusion during the current peak which occurs motor starting, the fuse type gG will be chosen sized from 1,5 to 2,5 the full load current of the motor. Such fuse has therefore to carry for a relatively long time a current higher than the rated one and this may cause a thermal overload dangerous for the motor. In order to assure an effective protection of the motor, it is recommended to couple the thermal overload relay with fuses type aM (motor accompanying) whose current is of the same order of size than the current of themotor to be protected. Disconnector Disconnection This device allow to insulate, in a total and sure way, all the conductors placed on the load side, before carrying out any intervention on the plant, following a failure or a need of maintenance. Switch-disconnector Control Disconnection It groups all the above mentioned functions, relating to disconnector. Automatic circuit braker Control Protection against overloads Protection against short-circuits Direct-on-line starter Control Protection against overloads It groups more than one of the above mentioned functions. This equipment consists of a contactor coupled to a thermal overload relay, able of starting, stopping and protecting a motor. Notes The protective device (fuse or automatic circuit breaker) should be chosen in such a way to co-ordinate the starter for failure currents which exceed the breaking capacity of the contactor or the limit let through energy of the thermal overload relay. The device should be located on the supply side of the starter and have a short-circuit breaking capacity not less than the short-circuit prospective current at its location. “Fuse-combination unit” is a general term covering the combination of a switch, a disconnector or a switch-disconnector and one or more fuses in a composite unit. Such unit performs the different functions carried out by each electrical device composing the unit 33 PROGRESSIVE PART No. INDEX Part no. ord. VC211100 VC218600 VC286300 VC290500 VC291300 VC298800 VC300200 VC301000 VC302800 VC303600 VC304400 VD420700 VD421500 VD422300 VD423100 VD424900 VD425600 VD428000 VD429800 VD430600 VD431400 VD432200 VD433000 VD434800 VD435500 VD444700 VD445400 VD446200 VD447000 VD448800 VD449600 VD450400 VD451200 VD452000 VD453800 VD454600 VD455300 VD456100 VD457900 VD459500 VD460300 VI806200 VI807000 VI808800 VI809600 VQ329600 VQ330400 VQ332000 VQ333800 VQ335300 VQ336100 VQ338700 VQ339500 VQ341100 VQ342900 VQ344500 VQ345200 VQ347800 VQ348600 VQ350200 VQ351000 VQ353600 VQ354400 VQ355100 VQ356900 VQ357700 34 Type no. B-G1280 B-KG6047 B-G813 XA0503BSP XA0504BSP XC050PB XC16AN XC16CN XC32AN XC32CN XC32GN XA0633BSP XA0634BSP XA0803BSP XA0804BSP XA1003BSP XA1004BSP XA0503BSL XA0504BSL XA0633BSL XA0634BSL XA0803BSL XA0804BSL XA1003BSL XA1004BSL XA0503BSN XA0504BSN XA0633BSN XA0634BSN XA0803BSN XA0804BSN XA1003BSN XA1004BSN XC063PB XC080PB XC100PB XC100GB B-G1305 B-G1304 XC012AB XC012CB XA0633BDSP XA0503BDSP XA0633BCSP XA0503BCSP KNZ16B3000 KNZ16B4000 KNZ16G3000 KNZ16G4000 KNZ16R3000 KNZ16R4000 KNZ30B3000 KNZ30B4000 KNZ30G3000 KNZ30G4000 KNZ30R3000 KNZ30R4000 KNZ40B3000 KNZ40B4000 KNZ40G3000 KNZ40G4000 KNZ40R3000 KNZ40R4000 XNA0503B XNA0633B XNA0803B IPage 13 13 13 11 11 12 12 12 12 12 12 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 12 12 12 12 13 13 12 12 11 11 11 11 6 6 8 8 6 6 6 6 8 8 6 6 6 6 8 8 6 6 6 6 6 Part no. ord. VQ358500 VQ362700 VQ363500 VQ364300 VQ365000 VQ366800 VQ367600 VQ380900 VQ381700 VQ382500 VQ383300 VQ384100 VQ385800 VQ387400 VQ388200 VQ389000 VQ391600 VQ392400 VQ393200 VQ403900 VQ404700 VQ405400 VQ407000 VQ408800 VQ409600 VQ413800 VQ416100 VQ422900 VQ425200 VQ428600 VQ429400 VQ430200 VQ431000 VQ432800 VQ433600 VQ434400 VQ436900 VQ438500 VQ439300 VQ441900 VQ442700 VQ446800 VQ447600 VQ448400 VQ449200 Z0063400 ZN869700 ZN880800 ZN880900 ZN881000 ZN881100 ZN881200 ZN881300 ZN881400 ZN881500 ZN881600 ZN881700 ZN882200 ZO061200 ZO061300 ZO061600 ZO061700 ZO062000 ZO062100 ZO062400 ZO062500 Type no. XNA1003B XNA163B XNA163G XNA163R XNA164B XNA164G XNA164R XNA323B XNA323G XNA323R XNA324B XNA324G XNA324R XNA1630BXL XNA1630BXN XNA1630BXP XNA1640BXL XNA1640BXN XNA1640BXP XNA3230BXL XNA3230BXN XNA3230BXP XNA3240BXL XNA3240BXN XNA3240BXP XNF163B XNF164B XNF323B XNF324B YNGK6 YNGL6 YNGT4 YNGT6 YNGY4 YNGY6 YNUK6 YNUL6 YNUT4 YNUT6 YNUY4 YNUY6 B-GNAM0 B-GNAP0 B-GNAP1 B-GNAP2 KNZ40B4000BYP B-GNAP4 XNA0503BC XNA0504BC XNA0633BC XNA0634BC XNA0803BC XNA0804BC XNA1003BC XNA1004BC YNUT6C YNUL6C YNUK6C KNZ16B3000BYL KNZ16B3000BYN KNZ16B4000BYL KNZ16B4000BYN KNZ30B3000BYL KNZ30B3000BYN KNZ30B4000BYL KNZ30B4000BYN IPage 6 6 8 6 6 8 6 6 8 6 6 8 6 10 10 10 10 10 10 10 10 10 10 10 10 6 6 6 6 8 8 8 8 8 8 7 7 7 7 7 7 13 13 13 13 9 13 7 7 7 7 7 7 7 7 7 7 7 9 9 9 9 9 9 9 9 Part no. ord. ZO062600 ZO062800 ZO062900 ZO063000 ZO063200 ZO063300 ZOO61400 ZOO61800 ZOO62200 Type no. KNZ30B4000BYP KNZ40B3000BYL KNZ40B3000BYN KNZ40B3000BYP KNZ40B4000BYL KNZ40B4000BYN KNZ16B3000BYP KNZ16B4000BYP KNZ30B3000BYP IPage 9 9 9 9 9 9 9 9 9 PROGRESSIVE TYPE No. INDEX Type no. ord. B-G1280 B-G1304 B-G1305 B-G813 B-GNAM0 B-GNAP0 B-GNAP1 B-GNAP2 B-GNAP4 B-KG6047 KNZ16B3000 KNZ16B3000BYL KNZ16B3000BYN KNZ16B3000BYP KNZ16B4000 KNZ16B4000BYL KNZ16B4000BYN KNZ16B4000BYP KNZ16G3000 KNZ16G4000 KNZ16R3000 KNZ16R4000 KNZ30B3000 KNZ30B3000BYL KNZ30B3000BYN KNZ30B3000BYP KNZ30B4000 KNZ30B4000BYL KNZ30B4000BYN KNZ30B4000BYP KNZ30G3000 KNZ30G4000 KNZ30R3000 KNZ30R4000 KNZ40B3000 KNZ40B3000BYL KNZ40B3000BYN KNZ40B3000BYP KNZ40B4000 KNZ40B4000BYL KNZ40B4000BYN KNZ40B4000BYP KNZ40G3000 KNZ40G4000 KNZ40R3000 KNZ40R4000 XA0503BCSP XA0503BDSP XA0503BSL XA0503BSN XA0503BSP XA0504BSL XA0504BSN XA0504BSP XA0633BCSP XA0633BDSP XA0633BSL XA0633BSN XA0633BSP XA0634BSL XA0634BSN XA0634BSP XA0803BSL XA0803BSN XA0803BSP XA0804BSL Part no. VC211100 VD457900 VD456100 VC286300 VQ446800 VQ447600 VQ448400 VQ449200 ZN869700 VC218600 VQ329600 ZO061200 ZO061300 ZOO61400 VQ330400 ZO061600 ZO061700 ZOO61800 VQ332000 VQ333800 VQ335300 VQ336100 VQ338700 ZO062000 ZO062100 ZOO62200 VQ339500 ZO062400 ZO062500 ZO062600 VQ341100 VQ342900 VQ344500 VQ345200 VQ347800 ZO062800 ZO062900 ZO063000 VQ348600 ZO063200 ZO063300 Z0063400 VQ350200 VQ351000 VQ353600 VQ354400 VI809600 VI807000 VD428000 VD444700 VC290500 VD429800 VD445400 VC291300 VI808800 VI806200 VD430600 VD446200 VD420700 VD431400 VD447000 VD421500 VD432200 VD448800 VD422300 VD433000 IPage 13 13 13 13 13 13 13 13 13 13 6 9 9 9 6 9 9 9 8 8 6 6 6 9 9 9 6 9 9 9 8 8 6 6 6 9 9 9 6 9 9 9 8 8 6 6 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 Type no. ord. XA0804BSN XA0804BSP XA1003BSL XA1003BSN XA1003BSP XA1004BSL XA1004BSN XA1004BSP XC012AB XC012CB XC050PB XC063PB XC080PB XC100GB XC100PB XC16AN XC16CN XC32AN XC32CN XC32GN XNA0503B XNA0503BC XNA0504BC XNA0633B XNA0633BC XNA0634BC XNA0803B XNA0803BC XNA0804BC XNA1003B XNA1003BC XNA1004BC XNA1630BXL XNA1630BXN XNA1630BXP XNA163B XNA163G XNA163R XNA1640BXL XNA1640BXN XNA1640BXP XNA164B XNA164G XNA164R XNA3230BXL XNA3230BXN XNA3230BXP XNA323B XNA323G XNA323R XNA3240BXL XNA3240BXN XNA3240BXP XNA324B XNA324G XNA324R XNF163B XNF164B XNF323B XNF324B YNGK6 YNGL6 YNGT4 YNGT6 YNGY4 YNGY6 Part no. VD449600 VD423100 VD434800 VD450400 VD424900 VD435500 VD451200 VD425600 VD459500 VD460300 VC298800 VD452000 VD453800 VD455300 VD454600 VC300200 VC301000 VC302800 VC303600 VC304400 VQ355100 ZN880800 ZN880900 VQ356900 ZN881000 ZN881100 VQ357700 ZN881200 ZN881300 VQ358500 ZN881400 ZN881500 VQ387400 VQ388200 VQ389000 VQ362700 VQ363500 VQ364300 VQ391600 VQ392400 VQ393200 VQ365000 VQ366800 VQ367600 VQ403900 VQ404700 VQ405400 VQ380900 VQ381700 VQ382500 VQ407000 VQ408800 VQ409600 VQ383300 VQ384100 VQ385800 VQ413800 VQ416100 VQ422900 VQ425200 VQ428600 VQ429400 VQ430200 VQ431000 VQ432800 VQ433600 IPage 11 11 11 11 11 11 11 11 12 12 12 12 12 12 12 12 12 12 12 12 6 7 7 6 7 7 6 7 7 6 7 7 10 10 10 6 8 6 10 10 10 6 8 6 10 10 10 6 8 6 10 10 10 6 8 6 6 6 6 6 8 8 8 8 8 8 Type no. ord. YNUK6 YNUK6C YNUL6 YNUL6C YNUT4 YNUT6 YNUT6C YNUY4 YNUY6 Part no. VQ434400 ZN882200 VQ436900 ZN881700 VQ438500 VQ439300 ZN881600 VQ441900 VQ442700 IPage 7 7 7 7 7 7 7 7 7 35 NOTE 36