air curtains radiant heaters fan heaters convectors thermostats
Transcription
air curtains radiant heaters fan heaters convectors thermostats
Mini catalogue 2012 air curtains radiant heaters fan heaters convectors thermostats For comfortable energy efficient indoor climate. Welcome News … to the 2012 edition of the Frico Mini Catalogue. At Frico we are proud to be able to offer energy-efficient products for a better indoor climate. In our products, the focus is on achieving the greatest possible function with the least possible energy consumption – without compromising on our core values of trust, competence and design. We hope this Mini Catalogue will be a useful tool when choosing the correct product for each application. For more extensive product information, we welcome you to visit our website, www.frico.se, where all technical information regarding our products is available. Together with company and product news, 3D models of our products, specifications texts, output calculation guide and much more, www.frico.se is the ideal source for full information regarding Frico’s product range. Looking forward to hearing from you! 1 No PA 3500/4200 Adaptable air curtains for installation heights up to 3,5 / 4,2 metres 2 No Carboninfra IC For fast and gentle heat with flexible installation 3 No UF600 Air curtains that blow from below for large doorways Pontus Grimberg International Sales Manager Managing director Jonas Valentin Managing Director T: +46 31 336 86 04 F: +46 31 26 28 25 [email protected] International Sales Sales support Pontus Grimberg Jan-Erik Lundholm International Sales Manager T: +46 31 336 86 35 F: +46 31 26 28 25 [email protected] International Area Manager T: +46 31 336 86 13 F: +46 31 26 28 25 [email protected] Hossein Mohrsazha Raimund Schüpp International Area Manager T: +46 31 336 86 45 F: +46 31 26 28 25 [email protected] International Area Manager T: +44 787 59 77 517 F: +46 31 26 28 25 [email protected] Yvonne Stenholm Sales Support Manager T: +46 31 336 86 16 F: +46 31 26 28 25 [email protected] Lena Majqvist Sales Support T: +46 31 336 86 38 F: +46 31 26 28 25 [email protected] Ingvor Thomsson Björklund Technical support 2 Do not hesitate to contact us! Mo - Fr 8.00 - 17.00 CET T +46 31 336 86 00 F +46 31 26 28 60 [email protected] Marketing and Sales Coordinator T: +46 31 336 86 06 F: +46 31 26 28 25 [email protected] Björn Sandqvist Susanne Andersson Technical Support Manager T: +46 31 336 86 14 F: +46 31 26 28 60 [email protected] Technical Support T: +46 31 336 86 17 F: +46 31 26 28 60 [email protected] Martin Ekman Adam Balogh Stephan Hansson Technical Support T: +46 31 336 86 34 F: +46 31 26 28 60 [email protected] Technical Support T: +46 31 336 86 10 F: +46 31 26 28 60 [email protected] Quality Manager T: +46 31 336 86 10 F: +46 31 26 28 60 [email protected] Cover: The new Opera house in Oslo, Norway. Photo: Erik Berg Air curtain AD200W (more information about that product on p 11) creates a comfortable indoor climate in this spectacular building. 6 Thermozone® Air curtains 32 Radiant heaters Thermozone guidelines 35 Thermoplus EC 3 10 Thermozone AD100 3, ADA 1 36 Thermocassette HP 3 11 Thermozone AD200 1 3 2 36 Elztrip EZ100 3 12 Thermozone AR200, recessed 3 2 1 37 Elztrip EZ200 3 13 Thermozone AR3500, recessed 3 2 38 Infrared heater IR 3 14 Thermozone AR300, recessed 3 2 39 Infrared heater CIR 3 7 37 Elztrip EZ300 3 38 Infrared heater IRCF 3 15 Thermozone Portier 1 3 39 Infrared heater ELIR 3 16 Thermozone AC Corinte 1 3 2 40 Infrared heater IH 3 17 Thermozone AD Corinte 1 3 2 41 Infrared heater IC 3 Thermozone SF, for circular/revolving doors 3 2 42 Comfort Panel SZR, water heated, recessed 2 Thermozone RD, for circular/revolving doors 3 2 1 43 18 19 20 Thermozone AD300 1 3 2 21 Thermozone AD400 1 3 2 22 Thermozone PA3500 1 3 2 Comfort Panel SZ, water heated 2 44 Controls ERP, CIRT, S123 57 57 58 Ceiling fans Ceiling fan ICF 3 Convectors 58 Benchheater SH 3 58 Frostguard FML 3 59 Ribbed pipe radiator 3 59 Thermowarm TWT, TWTC 3 60 Fan convector PFE, PFD 3 61 61 Fan convector PFW, waterheated 2 Other products 61 Dehumidifier LAF10 3 61 Hand dryer HD2C 3 62 Thermostats and controls 62 Room ther mostats T, TK, TD 62 2-step room thermostats RTI2, RTI2V 46 PA1006, doorheater 63 Capillary tube thermostats KRT 46 K21, 2 kW 3 63 Bimetal ther mostats TBK 63 Timer CBT, digital time switch KUR 64 Water contr ols VOS, VOSP, VOT, VMO, VMOP, VMT 66 Water contr ols VR20/25, TVV20/25, SD20 45 Fan heaters 22 Thermozone PA4200 1 3 2 24 Thermozone AG4500/5000 1 2 25 Thermozone AC500 1 47 Tiger, 2-9 kW, 15 kW, 20 and 30 kW 3 25 Thermozone UF60 0 1 48 Cat, 3-9 kW 3 26 Thermozone AGI 1 2 49 Elektra C/F/V/H 3 27 Thermozone ADA Cool, cold storage 1 50 Panther, 6-15 kW, 20 and 30 kW 3 28 Control system SIRe 52 SWH, water heated 2 30 Controls ADEA, CB, ADSR54, RTRD 55 SWS, water heated 2 31 Other accessories 56 67 Technical guide SWT, ceiling mounted, waterheated 2 Design and specifications are subject to change without notice. See www.frico.se for latest updated info. Frico products Today’s high and increasing energy prices often make heating costs substantial. Frico strives to develop products and systems that provide energy saving heating solutions and better heating comfort at the same time. Reducing energy losses and making optimum use of the heat is also important. Air curtains in doorways and openings, radiant heaters or ceiling fans where the ceiling is high are examples of products that contribute to large energy savings. Air curtains It makes sound economic sense to create an efficient and invisible door that keeps the heat inside. Air curtains can be even more effective when used in air conditioned or cold storage buildings. Thermozone technology with its precisely adjusted air velocity gives even protection throughout the opening. Frico air curtains provide the most efficient separation with the lowest possible energy consumption, regardless of whether it is the heat or the cold that you want to keep inside. Radiant heaters Frico radiant heaters imitate the sun, the most comfortable and efficient heat source available. The heat is emitted only when the rays hit a surface and the room temperature can thus be lowered while occupants experience a comfortable environment. This makes radiant heaters well suited not only for total heating but also for zone and spot heating, for example to avoid cold draughts from windows. Radiant heaters are easy to install and require minimum maintenance. They heat directly when switched on and give no air movement. Fan heaters We are proud of the worldwide fame Frico fan heaters have gained. They are reliable and are designed for long life. Our range covers all needs. The investment cost is low compared to other heating systems. A great advantage of fan heaters is the option of combining heating and ventilation. Frico fan heaters are compact, silent and light weight. They are available for electrical heating as well as for water heating. Convectors The circulation of air that forms in a room where the air is affected by a heat source is called convection. The air gets warm and rises, then cools and returns to be heated again. Heat disperses effectively while the upward directed warm air stream is utilized to counteract cold draughts from windows for example. Thermostats and controls Ceiling fan Ceiling fans push down overheated air from the ceiling to the living area. Losses are decreased and the heat is used to best effect. The key to energy efficient heating and good comfort is the combination of heating products and good controls. Frico offers a wide range of thermostats and controls, read more under each product or in the Frico Catalogues. More information More information on Frico and Frico products can be found on our website www.frico.se, in our main catalogues and other printed material that you can order from us or from our distributors. 4 Good reasons to choose Frico More than 75 years of experience of developing products for the varied Nordic climate has provided us with a unique knowledge bank. This is our foundation when creating today's energy efficient solutions for a comfortable indoor climate. Leading technique and design Frico is the leading supplier of air curtains, radiant heaters and fan heaters in Europe. All our products are well designed in good Scandinavian tradition. Knowledge and resources Since we develop our own products, our knowledge on how to create an energy efficient indoor climate is constantly growing. We have one of Europe's most modern and advanced air and sound laboratories to aid us. Qualified local support Frico is present locally in some 70 countries worldwide with a network of wholly-owned subsidiaries and independent distributors. Our highly qualified representatives are carefully chosen and together we are able to provide you with the best possible support. To find your nearest Frico subsidiary or distributor, please visit www.frico.se. Frico Academy The Academy is an important platform for networking and sharing inspiration and knowledge between us and our distributors around the world. Through the Frico Academy we share our knowledge on theory and technology, as well as product knowledge and experience in manufacturing and product development. Quality and long life Frico offers consistent and high product quality. Our product warranty is there for your safety. It covers manufacturing faults and is valid for five years and necessary components will be replaced. Frico products are designed for long life and are easy to maintain. Through our distribution network we provide reliable maintenance and service support which includes the availability of spare parts for at least ten years. Frico saves energy Thanks to our broad product range and our many years of experience, Frico is able to help you save energy. By offering total solutions, including both complete heating systems and products for additional heating, we can generate a comfortable indoor climate at a low energy cost. Our regulation systems for different levels ensure that you never use more energy than is required. Through our parent company, Systemair, we also possess knowledge about ventilation and can provide appropriate solutions. Climate-smart At Frico, we are proud to be able to offer energy-efficient products for a better indoor climate. In our product development work, the focus is on achieving the greatest possible function with the least possible energy consumption – without compromising on our core values of trust, competence and design. This means that our products not only manage the local climate in business complexes, industrial buildings, offices or summer cottages; with optimum energy efficiency, we ensure that our products are climate-smart. Frico's headoffice is located outside Gothenburg in Sweden and we are a part of the Systemair Group. Today Frico is represented in 70 countries world wide either by subsidiaries or distributors. Updated information is always available on our website www.frico.se. We manufacture at production units in Skinnskatteberg, Sweden and at other ISO-certified production units in Europe. Our warehouses are strategically placed in several places in Europe. 5 Air curtains - Thermozone® Thermozone air curtains create an invisible barrier at openings and doors which separates different temperature zones without limiting access for people and vehicles. With Thermozone Technology an efficient air separation is created in combination with a low sound level, giving comfortable climate and large energy savings. Thermozone air curtains are appreciated worldwide for their quality and operating efficiency, and are currently used in over 50 countries. Thermozone technology Energy savings and good indoor climate Scandinavian design In many buildings, such as shops, warehouses, industrial premises and goods terminals, doorways are open for a significant portion of the day. Expensive heated or cooled air will be lost, especially when the difference between the inside and outside temperatures is substantial. Thanks to Thermozone technology, performance can be precisely adjusted to obtain an air curtain with efficient separation that is also comfortable to pass through. R Thermozone air curtains are optimized in: •Airflowgeometry •Performance •Soundlevel Frico cooperates with leading architects and product designers to create today’s aesthetic products. The Thermozone range has an elegant Scandinavian design and for visible mounting there are models that harmonize with exclusive shop interiors as well as industrial buildings. Recessed mounting is also possible with only the outlet/inlet visible. Low sound level and high performance The Thermozone range has been developed and is manufactured in our plant in Skinnskatteberg, Sweden. Here we have one of the most sophisticated airflow and sound laboratories in Europe. Advanced equipment and expertise make it possible to produce air curtain products with the lowest sound level and the best performance. Air curtain knowledge We at Frico know most of what there is to know about air curtains and are happy to share that knowledge. We arrange for example The Frico Academy, a training forum for our distributors.Pleasesee"Thermozoneaircurtaincatalogue"for further information, or contact us directly. [oC] [cm] [cm] Opening Opening without aircurtain [cm] The heated or conditioned air escapes through this unprotected opening. The result is energy loss and poor comfort. 6 Opening [cm] Opening with correctly adjusted Thermozone® A sharp separation between different temperature zones is obtained with a correctly set up air curtain. Thermozone creates a barrier that effectively prevents undesired air flows. A i r cur t ai ns Choose the right air curtain For optimal air curtain effect, it is important to choose the right air curtain. Thermozone air curtains are available for doorways of any width and for heights up to 8 metres. They blow from above, from the side or from below. Choose between electrical, water heated or unheated versions. To get the most out of the product, the following hints are important to bear in mind. •Theinstallationheightiscrucial. •Theaircurtainunitsshouldcoverthewholewidth(or height) of the opening. Thermozone can be obtained indifferentlengths.Forwide(high)openings,several unitsaremountedbeside(ontop)ofeachother. •Theunitsshouldbepositionedasclosetotheopening as possible. •Foroptimalperformanceitisimportantthatthe pressure difference between outside and inside is not too big. Control For optimal comfort and energy saving the air curtain needs to be controlled according to the requirements and conditions at hand. A quick and precise control is easily obtained. Our control kits on 3 different levels for each product cover most needs. Read more about the control kits in our air curtain catalogue or on www.frico.se. Thermozone® - overview Type Application Installation height/width AD100 Small openings Up to 1,5 m ADA Entrance/cold storage Up to 2,5 m AD200 Entrance/cold storage Up to 2,5 m AR200 Entrance Up to 2,5 m AR3500 Entrance Up to 3,5 m AR300 Entrance Up to 3,5 m Portier Entrance Up to 2,5 m AC Corinte Entrance AD Corinte El. Water Ambient Mounting heated heated unheated Additional features Page Horizontal Cable and plug. AD105: only cable. 10 Horizontal Cable and plug. 10 3 2 2 2 2 Up to 3 m 3 3 3 3 3 3 Entrance Up to 3,5 m 3 2 SF Entrance Up to 4 m RD Entrance Up to 3 m AD300 Entrance/cold storage 2,5 m - 3,5 m AD400 Industry/cold storage 3m-4m PA3500 Entrance/cold storage 2,5 m - 3,5 m PA4200 Industry/cold storage 3 m - 4,2 m 3 3 3 3 3 3 AG4500/5000 Industry/cold storage Up to 5 m 2 2 2 2 2 2 2 AC500 Industry 3m-6m UF600 Industry Large doorways AGI Industry Large doorways ADA Cool Cold storage Up to 2,5 m 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 Horizontal 11 Horizontal Recessed model. 12 Horizontal Recessed model. 13 Horizontal Recessed model. 14 Horizontal Brushed stainless steel. 15 Horizontal/vertical Brushed stainless steel as standard. 16 Horizontal/vertical Polished, mirror polished or brushed stainless steel. 17 Vertical For revolving doors. 18 Horizontal For revolving doors. 19 Horizontal 20 Horizontal 21 Horizontal/vertical Recessed mounting possible Horizontal/vertical Recessed mounting possible 22 23 Horizontal 24 Horizontal/vertical 25 Vertical 25 Horizontal/vertical 26 Horizontal Special terminals for easy connection of several units. Cable and plug. 27 7 Air curtains - Thermozone® Installation examples for air curtains Thermozone air curtains are available for openings of different sizes and for different application areas. To facilitate your choice of product, you will find some typical cases on the following pages. More detailed information on important factors to consider when choosing an air curtain is found on the previous pages. Pleasenotethatitistheinstallationheightthatisdecisive and not the height of the opening. Basic criterias: 1. Type of premises: store, warehouse etc. 2. Height: installation height 3. Width: installation width 4. Mounting: horizontal or vertical 5.Connection:ambient,unheated(A),electrical(E),water(W) Small openings Kiosk or service hatch 1. Type of premises: Kiosk 2. Installation height: 1 m 3. Installation width: 0,8 m 4. Mounting: Horizontal 5. Connection: Electrical 1m 1m Recommendation: An AD102/103 is recommended for these conditions. For the 1,5 metre opening, two units are mounted side by side to cover the whole width. 0,8 m 1,5 m Shop 1. Type of premises: Shop 2. Installation height: 2,1 m 3. Installation width: 1 m 4. Mounting: Horizontal 5. Connection: Electrical 2,1 m 2,2 m Recommendation: An AD210E06 or AD210E09 is recommended for these conditions. 2. Installation height: 2,2 m 3. Installation width: 2 m 2m 1m Recommendation: A shop with a large entrance and a lot of traffic through the opening requires a larger unit to obtain a comfortable climate. For these conditions we recommend AD320E18. Bank 1. Type of premises: Bank 2. Installation height: 2,2 m 3. Installation width: 2 m 4. Mounting: Horizontal or vertical 5. Connection: Water 2,2 m 2m Entrance Recommendation: For an opening with high demands on design and performance we recommend one or two AD Corinte depending on the premises. AD Corinte can be installed horizontally or vertically. 8 2,2 m 2m A i r cur t ai ns Air curtains - Thermozone® Goods reception, grocery store 1. Type of premises: Goods reception, grocery store 2. Installation height: 3 m 3. Installation width: 3 m 4. Mounting: Horizontal 5. Connection: Water 3m Recommendation:TwoPA3515WLarerecommendedfor these conditions. 3m Warehouse 1. Type of premises: Warehouse 2. Installation height: 4 m 3. Installation width: 4 m 4. Mounting: Vertical 5. Connection: Water 4m Recommendation: Four vertically mounted PA4220WLbesidetheopening,twoateachsideare recommended for these conditions. 4m Factory, heavy industry 6m Recommendation: For these conditions we recommend UF600. Air is pressed out at high speed through a narrow slot in the floor inside the opening. UF600 provides nearly 100 % protection against cold draughts along the floor. 4m Industry 1. Type of premises: Factory, heavy industry 2. Installation height: 6 m 3. Installation width: 4 m 4. Mounting: Vertical 5. Connection: Ambient Cold room Recommendation: Two ADA Cool are recommended for these conditions, mounted side by side above the opening. 2,5 m 2,5 m Cold storage 1. Type of premises: Cold room 2. Installation height: 2,5 m 3. Installation width: 2,5 m 4. Mounting: Horizontal 5. Connection: Ambient 9 Thermozone® ADA Designed primarily for smaller openings such as kiosk and service hatches. The airflow can be regulated in two steps. Resetable overheat protection. Built-in thermostat (5-35 °C). Models AD102 and AD103 are equipped with cable and plug, AD105 only cable. Height: 217 mm Depth: 131 mm Colour: white, RAL 9016. CE compliant. Designed to prevent loss of conditioned air. Installation height up to 2,5 metres. Suitable where space is limited between the ceiling and the upper edge of the doorway. Without heat. With cable and plug. Built-in switch for high/low speed. Height: 235 mm Depth: 215 mm Colour: white, RAL 9016. CE compliant. 1,5 m Thermozone® AD100 0,8 m Thermozone AD100, electrically heated (IP20) 10 Type Voltage AD102 AD103 AD105 [V] 230V~ 230V~ 230V~ Heat output [kW] 0/1/2 0/1,5/3 0/3/4,5 Airflow [m³/h] 400 400 500 Thermozone ADA, ambient, unheated (IP21) 3 Sound level [dB(A)] 36/48 36/48 50 Conditions for sound level measurements, see page 67. Length [mm] 806 806 806 Type Voltage ADA090H ADA120H ADA090L ADA120L [V] 230V~ 230V~ 230 V~ 230 V~ Heat output [kW] 0 0 0 0 Airflow [m³/h] 1150 1400 820 1350 2,5 m Air curtains - Thermozone® Small openings and Entrance 0,9 / 1,2 m 1 Sound level [dB(A)] 43/54 44/51 43/54 48/55 Length [mm] 900 1200 900 1200 A i r cur t ai ns Air curtains - Thermozone® Entrance Thermozone® AD200A/E/W Installation height up to 2,5 metres. Recessed mounting possible. Height: 225 mm Depth: 350 mm Colour: white, RAL 9016. Approved by SEMKO and CE compliant. Thermozone AD200W, water heated (IP21) Type 2,5 m Heat Airflow Sound Length output* level [V] [kW] [m³/h] [dB(A)] [mm] AD210W 230V~ 7 1200 38/49 1020 AD215W 230V~ 12 1800 40/51 1530 AD220W 230V~ 15 2400 41/52 1960 *) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC. 1 / 1,5 / 2 m Thermozone AD200A, ambient, unheated (IP21) Type Voltage AD210A AD215A AD220A [V] 230V~ 230V~ 230V~ Heat output [kW] 0 0 0 Airflow [m³/h] 1400 2100 2800 1 Sound level [dB(A)] 41/51 43/53 44/54 Length [mm] 1020 1530 1960 Thermozone AD200C, electrically heated, built-in thermostat and control box, cable and plug (IP21) 3 Voltage AD210C03 AD210C05 [V] 230V~ 230V~ Heat output [kW] 0/2/3 0/2,3/4,5 Airflow [m³/h] 1400 1400 Sound level [dB(A)] 41/47 41/47 Thermozone AD200E, electrically heated (IP21) Type Voltage AD210E03 AD210E06 AD210E09 AD215E05 AD215E09 AD215E14 AD220E12 AD220E18 [V] 230V~ 400V3N~ 400V3N~ 400V3N~ 400V3N~ 400V3N~ 400V3N~ 400V3N~ Heat output [kW] 0/1,5/3 0/3/6 0/4,5/9 0/2,3/4,5 0/4,5/9 0/6,7/13,5 0/6/12 0/9/18 Airflow [m³/h] 1400 1400 1400 2100 2100 2100 2800 2800 Length [mm] 1020 1020 3 Sound level [dB(A)] 41/51 41/51 41/51 43/53 43/53 43/53 44/54 44/54 Length [mm] 1020 1020 1020 1530 1530 1530 1960 1960 Control kits AD200E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 CB32N, RTI2 and MDC, magnetic door contact with time relay CK03 Level 3 ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board Conditions for sound level measurements, see page 67. Control kits AD200W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat CK02W Level 2 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay CK03 Level 3 ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit. Control kit AD200A 1 Level 1 CB30N, controls the airflow in 3 steps Type 2 Voltage Accessories - AD200A/E/W Type Description CK01E Control kit Electric level 1 (CB32N, RTI2) CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK03 Control kit level 3 (ADEA, ADEAIS, ADEAEB) CK01W Control kit Water level 1 (CB30N, T10) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (A/W) CB32N Control box (E) ADSR54 Stepless fan speed control, IP54 ADEA Air curtain control ADEAEB External control board, IP55 ADEAIS External room sensor, IP30 ADEAGD1 Additional control board to acheive BMS functionality KRT2800 2-step room thermostat, IP55 RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 KUR Digital time switch, IP55 CBT Electronic timer, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator 22003 False ceiling grille 1192 mm 22004 False ceiling grille 1515 mm ADPK1 Suspension kit, max 1 m ADPF1 Suspension brackets (pair) More information about accessories on pages 30-31 and 62-66. 11 Air curtains - Thermozone® Entrance Thermozone® AR200A/E/W 2,5 m AR200 is especially suited for environments with high demands in respect of design. It is recessed in ceilings above entry doors and other small doors where the height is no greater than 2.5 metres. A low unit height makes it possible to install AR200 where ceiling space is limited. The recessed installation and low sound level makes AR200 very discreet. 1 / 1,5 / 2 m The visible bottom plate may be painted to make it blend even better with the premises. Just one model per length with a choice of outputs and voltages selectable on installation making it simple and flexible to adapt the output to current need. Installation height up to 2.5 metres. Height: 198 mm Depht: 432 mm Colour (bottom plate): white, RAL 9016 CE compliant. Thermozone AR200A, ambient, unheated (IP20) Type Voltage Output Airflow AR210A AR215A AR220A [V] 230V~ 230V~ 230V~ [kW] 0 0 0 [m³/h] 1200 1750 2400 1 Sound level [db(A)] 34/50 34/50 40/54 Length [mm] 1042 1552 2042 Control kits AR200A 1 Level 1 CB30N, controls the airflow in 3 steps Thermozone AR200E, electrically heated (IP20) 3 Type Output Output Airflow Sound Length steps steps level 400V3N~ 230V~ [kW] [kW] [m³/h] [db(A)] [mm] 0/3 0/6/9 AR210E09 1200 34/50 1042 0/3 0/3/5 0/4,5 0/6,8/11,3 AR215E11 1750 34/50 1552 0/4,5 0/4,5/6,8 0/6 0/12/18 AR220E18 2400 40/54 2042 0/6 0/6/10 AR200E is delivered as 9 kW, 11 kW and 18 kW (400 V3N~) models, but they are convertible to 230 V~ and different outputs as shown in above table. Control kits AR200E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 12 CB32N, RTI2 and MDC, magnetic door contact with time relay Conditions for sound level measurements, see page 67. Thermozone AR200W, water heated (IP20) Type Voltage Output 2 Airflow Sound Length level [V] [kW] [m³/h] [db(A)] [mm] AR210W 230V~ 7 1000 41/49 1042 230V~ 11 AR215W 1600 37/50 1552 AR220W 230V~ 14 2000 44/53 2042 *) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC. Control kits AR200W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat CK02W Level 2 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit. Accessories - AR200 Type Description CK01E Control kit Electric level 1 (CB32N, RTI2) CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK01W Control kit Water level 1 (CB30N, T10) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB32N Control box (E) CB30N Control box (A/W) T10 Electronic thermostat, IP44 KRT2800 2-step room thermostat, IP55 RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 MDC Magnetic door contact with time relay, IP44 MDCDC Magnetic door contact CBT Electronic timer, IP44 KUR Digital time switch, IP55 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator More information about accessories on pages 30-31 and 62-66. A i r cur t ai ns Air curtains - Thermozone® Entrance Thermozone® AR3500E/W Accessories - AR3500E/W Type 3,5 m AR3500 is especially suited for environments with high demands in respect of design. The recessed installation is very discreet and the built-in control contributes further to the concealed appearance. Installation height up to 3,5 metres. Easy to service via a large hatch in the bottom of the unit. The filter is cleaned from the outside. Height: 302 mm Depth: 595 mm Colour (frame and hatch): white, RAL9016. Other colours as option. Approved by SEMKO and CE compliant. 1 / 1,5 / 2 m Thermozone AR3500E, electrically heated (IP44)* Type Voltage AR3510E09 AR3515E14 AR3520E18 [V] 400V3~ 400V3~ 400V3~ Heat output [kW] 0/4,5/9 0/7/13,5 0/9/18 Airflow [m³/h] 2000 2800 4000 Thermozone AR3500W, water heated (IP44)* Type 3 Sound level [dB(A)] 43/59 43/60 46/63 Length [mm] 1057 1567 2073 2 Voltage Heat Airflow Sound Length output* level [V] [kW] [m³/h] [dB(A)] [mm] AR3510W 230V~ 16 2000 43/58 1057 AR3515W 230V~ 23 2800 43/59 1567 AR3520W 230V~ 33 4000 46/62 2073 *) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC. *) Protection class AR3500E/W recessed mounting: above false ceiling – splash-proof design (IP44), below false ceiling: normal design (IP20). Control options This air curtain is supplied with an intregrated PC board SIRe. SIRe is an intelligent and well designed low voltage control system which can be customised for each unique application and environment. SIRe is supplied pre-programmed with quick fit plug connections and is very easy to use and install. If more than one air curtain should be controlled by a single SIRe, an additional modular cable SIReCC per unit is needed. Cables between units can easily be joined together by using joint piece SIReCJ. There are three different levels with different functionality to choose from, Basic, Competent or Advanced. Description Control system SIRe Basic Control system SIRe Competent Control system SIRe Advanced External room temperature sensor Kit for recessed installation Clamp-on sensor Used to join two RJ11(4/4) Used to join two RJ12 (6/6) Modular cable RJ12 3 m Modular cable RJ12 5 m SIReCC610 Modular cable RJ12 10 m SIReCC615 Modular cable RJ12 15 m SIReCC403 Modular cable RJ11 3 m SIReCC405 Modular cable RJ11 5 m SIReCC410 Modular cable RJ11 10 m SIReCC415 Modular cable RJ11 15 m VOS15LF Valve kit on/off, low flow, DN15, Kvs 0,90 VOS15NF Valve kit on/off, DN15, Kvs 1,8 VOS20 Valve kit on/off, DN20, Kvs 3,4 VOS25 Valve kit on/off, DN25, Kvs 7,2 VOSP15LF Pressure independent valve kit, low flow, DN15 VOSP15NF Pressure independent valve kit, DN15 VOSP20 Pressure independent valve kit, DN20 VOSP25 Pressure independent valve kit, DN25 VOT15 3-way control valve and actuator on/off, DN15, Kvs 1,7 VOT20 3-way control valve and actuator on/off, DN20, Kvs 2,5 VOT25 3-way control valve and actuator on/off, DN25, Kvs 4,5 VMO15LF Modulating valve kit, low flow, DN15, Kvs 0,40 VMO15NF Modulating valve kit, DN15, Kvs 1,0 VMO20 Modulating valve kit, DN20, Kvs 2,0 VMO25 Modulating valve kit, DN25, Kvs 4,0 VMOP15LF Pressure independent modulating valve kit, low flow, DN15 VMOP15NF Pressure independent and modulating valve kit, DN15 VMOP20 Pressure independent and modulating valve kit, DN20 VMOP25 Pressure independent and modulating valve kit, DN25 VMT15 3-way control valve and modulating actuator, DN15, Kvs 1,7 VMT20 3-way control valve and modulating actuator, DN20, Kvs 2,5 VMT25 3-way control valve and modulating actuator, DN25, Kvs 4,5 VAT Adjustment tool AR35XTT10 Extension for AR3510 SIReB SIReAC SIReAA SIReRTX SIReUR SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 AR35XTT15 Extension for AR3515 AR35XTT20 Extension for AR3520 More information about accessories on pages 28-29 and 66. Product specific accessories, AR3500 Water control Valve kit VOS(P), VOT, VMO(P) or VMT is used to control the water flow, see final section of this catalogue. AR35XTT, extension Outlet/inlet extension for a discreet installation with only the outlet and inlet visible in the ceiling. 13 Air curtains - Thermozone® Entrance Thermozone® AR300E/W Control 3,5 m AR300 is especially suited for environments with high demands in respect of design. The recessed installation is very discreet and the built-in control contributes further to the concealed appearance. Installation height up to 3,5 metres. Easy to service via a large hatch in the bottom of the unit. The filter is cleaned from the outside. Height: 302 mm Depth: 595 mm Colour (frame and hatch): white, RAL9016 Approved by SEMKO and CE compliant. 1 / 1,5 / 2 m Thermozone AR300E, electrically heated (IP44) Type Voltage AR310E09 AR315E14 AR320E18 [V] 400V3~ 400V3~ 400V3~ Heat output [kW] 0/4,5/9 0/7/13,5 0/9/18 Airflow [m³/h] 2000 2800 4000 Thermozone AR300W, water heated (IP44) Type Accessories - AR300 3 Sound level [dB(A)] 43/59 43/60 46/63 The built-in control of AR300 is designed to give the highest level of functionality while minimizing installation and daily operation. No additional wiring or external controls are needed. If the distance between the eye and the reflector is too long, it is possible to use an external door contact instead (accessory). The air curtain operates at its maximum performance in all situations and is not dependent on day-to-day adjustments. When the door is open the air curtain separates outdoor and indoor air and provides heat if it is needed. When the door is closed the air curtain operates as part of the heating system supplying additional heat if indoor temperature falls below desired temperature. There are also possibilities to connect the air curtain to a BMS system for on/ off control and alarm indication. Length [mm] 1057 1567 2073 2 Voltage Heat Airflow Sound Length output* level [V] [kW] [m³/h] [dB(A)] [mm] AR310W 230V~ 16 2000 43/58 1057 AR315W 230V~ 23 2800 43/59 1567 AR320W 230V~ 33 4000 46/62 2073 *) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC. Type Description AR300DS External door contact, with 7 m cable AR300ERS External room sensor, with 7 m cable VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator More information about accessories on page 66. Recommended set of valves Type AR310W AR315W AR320W Water temperature VR20 60/40 80/60 60/40 80/60 60/40 80/60 X X X Product specific accessories, AR300 The thermostat setting and open door fan speed selection is hidden under the cover. The IR-eye detects when the door is open and closed. The thermostat is located by the air intake and heat or ambient mode is set by a push button. Alarm indication by LED. 14 Conditions for sound level measurements, see page 67. VR25 AR300DS, external door contact When the distance between the eye and the reflector is too long an external door contact AR300DS is needed. The external door contact is supplied with 7 m cable and a modular contact for easy and quick installation (no other adjustments are needed to get the accessories working). The connection of the door contact is done on the control box accessible by opening the service hatch of the AR300. AR300ERS, external room sensor If an external room sensor is needed, use the AR300ERS. The external room sensor is supplied with 7 m cable and a modular contact for easy and quick installation (no other adjustments are needed to get the accessories working). The connection of the room sensor is done on the control box accessible by opening the service hatch of the AR300. X X X A i r cur t ai ns Air curtains - Thermozone® Entrance Thermozone® Portier 200 A/E For exclusive entrances. Installation height up to 2,5 metres. Mounting brackets available as an accessory. Overheat protection. Height: 280 mm Depth: 295 mm Colour: brushed stainless steel. CE compliant. 2,5 m P2WB 1 1 / 1,5 m Thermozone Portier 200A, ambient, unheated (IP21) Type Voltage PS210A PS215A [V] 230V~ 230V~ Heat output [kW] 0 0 Airflow [m³/h] 1300 2000 1 Sound level [dB(A)] 44/54 46/56 Length P2JK [mm] 1020 1530 2 Control kits Portier 200A 1 Level 1 CB20, controls the airflow in 2 steps 3 Thermozone Portier 200E, electrically heated (IP21) Type 3 Voltage Heat Airflow Sound Length output level [V] [kW] [m³/h] [dB(A)] [mm] PS210E03 230V~/400V3N~* 0/1,5/3 1200 44/50 1020 PS210E06 400V3N~* 0/3/6 1200 44/50 1020 PS210E09 400V3N~* 0/4,5/9 1200 44/50 1020 PS215E09 400V3N~* 0/4,5/9 1900 39/50 1530 PS215E14 400V3 + 230V~ 0/6,7/13,5 1900 39/50 1530 *) Alternative 400 V3~ + 230 V~ (operating supply) if the current is greater than 16 A. Applies when connecting several units. Control kits Portier 200E 3 Level 1 CB22, controls the airflow in 2 steps and the heat output in 2 steps RTI2, 2-step room thermostat Level 2 CB22, RTI2 and MDC, magnetic door contact with time relay Level 3 ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAEB, external control board Accessories - Portier 200A/E Type Description CB20 Control box (A) CB22 Control box (E) ADSR54 Stepless fan speed control, IP54 ADEA Air curtain control ADEAEB External control board, IP55 ADEAIS External room sensor, IP30 ADEAGD1 Additional control board to acheive BMS functionality RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 MDC Magnetic door contact with time relay, IP44 ADPK1 Suspension kit, max 1 m ADPF1 Suspension brackets (pair) P2WB Wall mounting kit P2JK Joining kit 2x1 m More information about accessories on pages 30-31 and 62-63. 15 Thermozone® AC Corinte E/W For exclusive entrances with high demands on design, noise level and finish. Slim design in stainless steel. Mounted with one unit on either side of the opening, thus creating a classic symmetry. Can also be mounted horizontally. Installation width up to 5 metres (2 units). Installation height up to 3 metres. Height/depth: 393 mm Depth/width: 314 mm Colour: brushed stainless steel (option: polished or mirror polished stainless steel) CE compliant. Ordering key: see AD Corinte Thermozone AC Corinte E, electrically heated (IP20) Type 5m Type 2 Voltage Airflow Heat Sound Height/ output*2 level Length [kW] [V] [m³/h] [dB(A)] [mm] 230V~ 19 1900 44/61 1500 ACC10WL*1 ACC15WL*1 230V~ 29 2600 45/62 1500 ACC20WL 230V~ 42 3800 47/64 2000 ACC25WL 230V~ 52 4500 48/65 2500 ACC30WL 230V~ 60 5100 48/65 3000 *1) ACC10WL and ACC15WL are available only for horizontal mounting *2) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC 3 Voltage Control kits ACC E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 CB32N, RTI2 and MDC, magnetic door contact with time relay CK03GD Level 3 ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board ADEAGD1, extra control board Conditions for sound level measurements, see page 67. 1,0 / 1,5 / 2,0 / 2,5 / 3,0 m Thermozone AC Corinte WL, water heated (IP20) Heat Airflow Sound Height/ output level Length [V] [kW] [m³/h] [dB(A)] [mm] 1900 44/61 1000 ACC10E*1 230V~/400V3~ 0/6/9 ACC15E*1 230V~/400V3~ 0/8/12 2600 45/62 1500 ACC20E 230V~/400V3~ 0/12/18 3800 47/64 2000 ACC25E 230V~/400V3~ 0/12/18 4500 48/65 2500 ACC30E*2 230V~/400V3~ 0/20/30 5100 48/65 3000 *1) ACC10E and ACC15E are available only for horizontal mounting 2 * ) ACC30E is available in special design with output steps 0/12/18 kW. 16 3m 2,0 / 2,5 / 3,0 m Air curtains - Thermozone® Entrance Control kit s ACC W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat CK02W Level 2 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay CK03GD Level 3 ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board ADEAGD1, extra control board Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit. Accessories - AC Corinte E/W Type Description Control kit Electric level 1 (CB32N, RTI2) Control kit Electric level 2 (CB32N, RTI2, MDC) Control kit level 3 (ADEA, ADEAIS, ADEAEB, ADEAGD1) Control kit Water level 1 (CB30N, T10) Control kit Water level 2 (CB30N, RTI2, MDC) Control box (A/W) Control box (E) Air curtain control External control board, IP55 External room sensor, IP30 Additional control board to acheive ADEA and BMS functionality RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat, knob, IP44 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 AGB304 Door contact, IP44 KUR Digital time switch, IP55 CBT Electronic timer, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator ACCWBP Wall bracket polished bright annealed* ACCWBB Wall bracket brushed stainless steel* ACCWBMP Wall bracket mirror polished stainless steel* AXP300 Collision protection *) For ACC 1-1,5 m: order 2 pcs, for ACC 2-3 m: order 3 pcs. More information about accessories on pages 30-31 and 62-66. . CK01E CK02E CK03GD CK01W CK02W CB30N CB32N ADEA ADEAEB ADEAIS ADEAGD1 For exclusive entrances with high demands on design, noise level and finish. Mounted with one unit on either side of the opening, thus creating a classic symmetry. Can also be mounted horizontally. Installation width up to 5 metres (2 units). Installation height up to 3,5 metres. Height/depth: 500 mm Depth/width: 350 mm Colour: polished, mirror polished or brushed stainless steel. Colour intake and outlet grille: black, RAL 9005. CE compliant. ADCS17A*¹ ADCS22A ADCS25A*² [V] 230V~ 230V~ 230V~ Heat output [kW] 0 0 0 Control options This air curtain is supplied with an intregrated PC board SIRe. SIRe is an intelligent and well designed low voltage control system which can be customised for each unique application and environment. SIRe is supplied pre-programmed with quick fit plug connections and is very easy to use and install. If more than one air curtain should be controlled by a single SIRe, an additional modular cable SIReCC per unit is needed. Cables between units can easily be joined together by using joint piece SIReCJ. There are three different levels with different functionality to choose from, Basic, Competent or Advanced. Airflow Voltage [m³/h] 3000 4000 4500 ADCS17E*¹ ADCS22E ADCS25E*² [V] 230V~/400V3~ 230V~/400V3~ 230V~/400V3~ Heat output [kW] 0/7,5/15 0/10/20 0/11,2/22,5 1 Sound level [dB(A)] 40/60 42/61 43/63 Thermozone AD Corinte E, electrically heated (IP20) Type 1,7 / 2,2 m 5m Thermozone AD Corinte A, ambient, unheated (IP20) Voltage 3,5 m 2,2 / 2,5 m Thermozone® AD Corinte A/E/W Type A i r cur t ai ns Air curtains - Thermozone® Entrance Airflow 3 Sound level [dB(A)] 40/60 42/61 43/63 [m³/h] 3000 4000 4500 Height/ Length [mm] 1700 2200 2450 Height/ Length [mm] 1700 2200 2450 Water control Valve kit VOS(P), VOT, VMO(P) or VMT is used to control the water flow, see final section of this catalogue. Accessories - AD Corinte A/E/W Type Description SIReB SIReAC SIReAA ADCMP ADCMS ADCEH AXP300 Control system SIRe Basic Control system SIRe Competent Control system SIRe Advanced Joining kit for suspended installation Joining kit for wall installation Extension hood AD Corinte Collision protection See AR3500 for accessories for SIRe and valve kits. Thermozone AD Corinte W, water heated (IP20) Type 2 Voltage Airflow Sound Height/ Heat output*3 level Length [kW] [V] [m³/h] [dB(A)] [mm] ADCS17WL*¹ 230V~ 33 3000 39/59 1700 ADCS22WL 230V~ 46 4000 42/60 2200 ADCS25WL*² 230V~ 52 4500 42/61 2450 *¹) ADCS17 is available only for horizontal mounting. *²) ADCS25 is available only for vertical mounting. *3) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC. Ordering key AC Corinte and AD Corinte Type - Unit shape - Connections position - Finish / Material Example: ADCS20WL - VL - A - P Type See technical specifications Unit shape HL (Horizontal, connections to the left), HR (Horizontal, connections to the right) VL (Vertical Left) or VR (Vertical Right) seen from the inside Connections position A or B, see below. Finish / material P = Polished bright annealed B = Brushed stainless steel MP = Mirror polished stainless steel Product specific accessories, AD Corinte ADCEH, extension hood Extension hood used to cover the space between the ceiling and the air curtain for a neat finish. Connections position ADCM P/S, joining kit for horizontal mounting Joining kit that is used when several AD Corinte are put together to give a neater and more unified installation. ADCMP for suspended installation and ADCMS for wall installation. HL Conditions for sound level measurements, see page 67. A A B B HR 17 Air curtains - Thermozone® Entrance 4m Thermozone® SF For circular and revolving doors with openings up to 4 metres wide. Mounted vertically beside the opening. Curved design that integrates neatly with the door. Extension possible up to 3900 mm (extension without fans). Units higher than 3000 mm are delivered in two pieces. Several optional finishes are available. Depth: 270 mm Width: 560 mm CE compliant. Thermozone SF E, electrically heated (IP20) Type Voltage SF18E09 SF24E12 SF36E18 SF54E30 [V] 400V3~ 400V3~ 400V3~ 400V3~ Heat output [kW] 0/6/9 0/8/12 0/12/18 0/20/30 Airflow [m³/h] 1800 2400 3600 5400 Thermozone SF W, water heated (IP20) Type Heat Airflow Sound Height output* level [V] [kW] [m³/h] [dB(A)] [mm] SF18WL 230V~ 18 1800 55 2200 SF24WL 230V~ 23 2400 56 2200 SF36WL 230V~ 38 3600 57 2200 SF54WL 230V~ 49 5400 57 2200 *) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC. Control kit SF W 2 CK02W CB30N, controls the airflow in 3 steps Level 2 RTI2, 2-step room thermostat MDC, magnetic door contact with time relay 3 Sound level [dB(A)] 55 56 57 57 2 Voltage Height [mm] 2200 2200 2200 2200 Control kit SF E 3 CK02E CB32N, controls the airflow in 3 steps and the heat Level 2 output in 2 steps RTI2, 2-step room thermostat MDC, magnetic door contact with time relay Note! A three-way motor valve with actuator and by-pass valve VKSF (option: VR20/25 or only TVV20/25 with SD20) should be added for a complete control kit. Accessories - SF E/W Type Description CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (W) CB32N Control box (E) RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator VKSF Built-in valve set for SF FH25 Flexible hose DN25, L=1 m, 2 pcs More information about accessories on pages 30-31 and 62-66. Finish / Material selection 18 Powder coating RAL State RAL code Powder coating NCS State NCS code Stainless steel, brushed grain 240 State B240 Stainless steel, polished bright annealed State P Stainless steel, mirror polished State M (not standard) Conditions for sound level measurements, see page 67. A i r cur t ai ns Air curtains - Thermozone® Entrance Thermozone® RD For circular and revolving doors of all sizes with opening height up to 3 metres. Discreet mounting on top of the revolving door with only the outlet grille visible. The outlet is adapted to fit the revolving door. Several optional finishes are available. Height: 250 mm Depth: 520 mm CE compliant. Thermozone RD E, electrically heated (IP20) Type Voltage RD18E09 RD27E15 RD36E23 RD54E30 RD63E36 [V] 400V3~ 400V3~ 400V3~ 400V3~ 400V3~ Heat output [kW] 0/6/9 0/10/15 0/15/22,5 0/20/30 0/24/36 Airflow [m³/h] 1800 2700 3600 5400 6300 Thermozone RD W, water heated (IP20) Type Heat Airflow Sound Length output* level [V] [kW] [m³/h] [dB(A)] [mm] RD18WL 230V~ 16 1800 48 1000 RD27WL 230V~ 19 2400 49 1000 RD36WL 230V~ 29 3500 50 1500 RD54WL 230V~ 42 5100 51 2000 RD63WL 230V~ 51 6000 52 2500 *) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC. 3m Control kit RD W 2 CK02W CB30N, controls the airflow in 3 steps Level 2 RTI2, 2-step room thermostat MDC, magnetic door contact with time relay 3 Sound level [dB(A)] 48 49 50 51 52 2 Voltage Length [mm] 1000 1000 1500 2000 2500 Control kit RD E 3 CK02E CB32N, controls the airflow in 3 steps and the heat Level 2 output in 2 steps RTI2, 2-step room thermostat MDC, magnetic door contact with time relay Note! A three-way motor valve with actuator and by-pass valve VKRD (option: VR20/25 or only TVV20/25 with SD20) should be added for a complete control kit. Accessories - RD E/W Type Description CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (W) CB32N Control box (E) RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 T10 Room thermostat, IP30 MDC Magnetic door contact with time relay, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator VKRD Built-in valve set for RD AFTRD Built-in antigel thermostat for RD FH25 Flexible hose DN25, L=1 m, 2 pcs More information about accessories on pages 30-31 and 62-66. Finish / Material selection Powder coating RAL State RAL code Powder coating NCS State NCS code Stainless steel, brushed grain 240 State B240 Stainless steel, polished bright annealed State P Stainless steel, mirror polished State M (not standard) Conditions for sound level measurements, see page 67. 19 Air curtains - Thermozone® Entrance Thermozone® AD300A/E/W Thermozone AD300W, water heated (IP20) Installation height 2,5-3,5 metres. Combines high performance with a compact size and an elegant design. Recessed mounting possible. Height: 340 mm Depth: 490 mm Colour: white, RAL 9016. Approved by SEMKO and CE compliant. Type 2,5 - 3,5 m Heat Airflow Sound Length output* level [V] [kW] [m³/h] [dB(A)] [mm] AD310W 230V~ 22 1800 44/57 1025 AD315W 230V~ 37 3000 46/59 1565 AD320W 230V~ 46 3600 47/60 2028 *) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC. 1 / 1,5 / 2 m Thermozone AD300A, ambient, unheated (IP20) Type Voltage AD310A AD315A AD320A [V] 230V~ 230V~ 230V~ Heat output [kW] 0 0 0 Airflow [m³/h] 1900 3200 3800 1 Sound level [dB(A)] 46/57 47/60 50/61 Length [mm] 1025 1565 2028 CB30N and MDC, magnetic door contact with time relay Thermozone AD300E, electrically heated (IP20) Type Voltage AD310E09 AD315E14 AD320E18 [V] 400V3~ 400V3~ 400V3~ Heat output [kW] 0/4,5/9 0/7/13,5 0/9/18 Airflow [m³/h] 1900 3200 3800 Length [mm] 1025 1565 2028 Control kits AD300E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 CB32N, RTI2 and MDC, magnetic door contact with time relay CK03 Level 3 ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB*, external control board *) ADEAEB can be replaced by internal control board ADEAIB, all items must then be ordered separately and not as a kit. 20 Conditions for sound level measurements, see page 67. CK02W Level 2 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay CK03 Level 3 ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB*, external control board Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit. Accessories - AD300A/E/W 3 Sound level [dB(A)] 46/57 47/60 50/61 Control kits AD300W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat *) ADEAEB can be replaced by internal control board ADEAIB, all items must then be ordered separately and not as a kit. Control kits AD300A 1 Level 1 CB30N, controls the airflow in 3 steps Level 2 2 Voltage Type Description CK01E Control kit Electric level 1 (CB32N, RTI2) CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK03 Control kit level 3 (ADEA, ADEAIS, ADEAEB) CK01W Control kit Water level 1 (CB30N, T10) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (A/W) CB32N Control box (E) ADSR54 Stepless fan speed control, IP54 ADEA Air curtain control ADEAEB External control board, IP55 ADEAIS External room sensor, IP30 ADEAIB Internal control board ADEAGD1 Additional control board to acheive BMS functionality KRT2800 2-step room thermostat, IP55 RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 40001 2-step room thermostat, IP55 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 KUR Digital time switch, IP55 CBT Electronic timer, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator 22003 False ceiling grille 1192 mm 22004 False ceiling grille 1515 mm ADPK1 Suspension kit, max 1 m ADPF1 Suspension brackets (pair) More information about accessories on pages 30-31 and 62-66. A i r cur t ai ns Air curtains - Thermozone® Industry Thermozone® AD400A/E/W Thermozone AD400W, water heated (IP20) Installation height up to 4 metres Combines high performance with a compact size and an elegant design. Recessed mounting possible. Height: 340 mm Depth: 490 mm Colour: white, RAL 9016. Approved by SEMKO and CE compliant. Type 4m Heat Airflow Sound level Length output* [V] [kW] [m³/h] [dB(A)] [mm] AD410W3 230V~ 25 2300 53/62 1025 AD415W3 230V~ 43 3800 39/63 1565 AD420W3 230V~ 56 4800 55/65 2028 *) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC. 1 / 1,5 / 2 m Thermozone AD400A, ambient, unheated (IP20) Type AD410A AD415A AD420A Voltage [V] 230V~ 230V~ 230V~ Heat output [kW] 0 0 0 Airflow [m³/h] 2500 4200 5000 1 Sound level [dB(A)] 48/63 35/64 50/65 Length [mm] 1025 1565 2028 CB30N and MDC, magnetic door contact with time relay Thermozone AD400E, electrically heated (IP20) Type Voltage AD410E14 AD415E20 AD420E27 [V] 400V3~ 400V3~ 400V3~ Heat output [kW] 0/9/13,5 0/13,5/20 0/18/27 Airflow [m³/h] 2500 4200 5000 CB32N, RTI2 and MDC, magnetic door contact with time relay CK03 Level 3 ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB*, external control board [mm] 1025 1565 2028 *) ADEAEB can be replaced by internal control board ADEAIB, all items must then be ordered separately and not as a kit. Conditions for sound level measurements, see page 67. CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay CK03 Level 3 ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB*, external control board Accessories - AD400A/E/W Length Control kits AD400E 3 CK01E CB32N, controls the airflow in 3 steps and the heat Level 1 output in 2 steps RTI2, 2-step room thermostat CK02E Level 2 CK02W Level 2 Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit. 3 Sound level [dB(A)] 48/63 35/64 50/65 Control kits AD400W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat *) ADEAEB can be replaced by internal control board ADEAIB, all items must then be ordered separately and not as a kit. Control kits AD400A 1 Level 1 CB30N, controls the airflow in 3 steps Level 2 2 Voltage Type Description CK01E Control kit Electric level 1 (CB32N, RTI2) CK02E Control kit Electric level 2 (CB32N, RTI2, MDC) CK03 Control kit level 3 (ADEA, ADEAIS, ADEAEB) CK01W Control kit Water level 1 (CB30N, T10) CK02W Control kit Water level 2 (CB30N, RTI2, MDC) CB30N Control box (A/W) CB32N Control box (E) ADSR54 Stepless fan speed control, IP54 ADEA Air curtain control ADEAEB External control board, IP55 ADEAIS External room sensor, IP30 ADEAIB Internal control board ADEAGD Additional control board to acheive BMS functionality KRT2800 2-step room thermostat, IP55 RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 40001 2-step room thermostat, IP55 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 AGB304 Door contact, IP44 KUR Digital time switch, IP55 CBT Electronic timer, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator 22003 False ceiling grille 1192 mm 22004 False ceiling grille 1515 mm ADPK1 Suspension kit, max 1 m ADPF1 Suspension brackets (pair) More information about accessories on pages 30-31 and 62-66. 21 3,5 / 4,2 m Air curtains - Thermozone® Entrance 1 / 1,5 / 2 / 2,5 m 1,5 / 2 / 2,5 m Thermozone® PA3500/4200 Air curtain PA3500/4200 gives more possibilities than ever before, packed into the same product. There are therefore many areas of use. PA3500/4200 has a modern and stylish design developed to fit all entrances. The air curtain is available for horizontal, vertical and recessed installation. •Colourfrontandservicehatch:RAL9016,NCS0500(white). Colour grille, rear section and ends: RAL 7046 (grey). Thermozone® PA3500 Thermozone® PA4200 PA3500 is particularly suitable in entrances to stores and shopping centres for example. •Installationheightupto3,5metres •Installationwidthupto5metres(2units) •Height:270mm •Depth:525mm •CEcompliant. PA4200 is specifically designed for doorways in for example, industrial and warehouse buildings or large commercial installations. •Installationheightupto4,2metres •Installationwidthupto6metres(2units) •Height:295mm •Depth:611mm •CEcompliant. Thermozone PA3500 A, ambient, unheated (IP20) 1 Type Voltage PA3510A PA3515A PA3520A PA3525A [V] 230V~ 230V~ 230V~ 230V~ Heat output [kW] 0 0 0 0 Airflow [m³/h] 1800 2600 3200 4600 Sound level [dB(A)] 40/57 41/59 42/60 42/61 Thermozone PA4200 A, ambient, unheated (IP20) 1 Length Type Voltage [mm] 1039 1549 2039 2549 PA4210A PA4215A PA4220A PA4225A [V] 230V~ 230V~ 230V~ 230V~ Thermozone PA3500 E, electrically heated (IP20) 3 Type Voltage PA3510E08 PA3515E12 PA3520E16 PA3525E20 [V] 230V~/400V3~ 230V~/400V3~ 230V~/400V3~ 230V~/400V3~ Heat output [kW] 2,7/5,4/8,0 3,9/7,8/12,0 5,4/10,8/16,0 6,6/13,2/20,0 Airflow Sound level [m³/h] [dB(A)] 1800 40/57 2600 41/59 3200 42/60 4600 42/61 Voltage • Longer3mmodel • ModelwithECmotorsfor extra energy efficiency • WatercoilWLLforverylow water temperatures 22 Airflow [m³/h] 2700 3700 5300 6350 Sound level [dB(A)] 46/64 46/64 47/65 49/67 Length [mm] 1039 1549 2039 2549 Thermozone PA4200 E, electrically heated (IP20) 3 Type Voltage [mm] 1039 1549 2039 2549 PA4210E12 PA4215E18 PA4220E24 PA4225E30 [V] 230V~/400V3~ 230V~/400V3~ 230V~/400V3~ 230V~/400V3~ Heat Airflow Sound Length output* level [V] [kW] [m³/h] [dB(A)] [mm] PA3510WL 230V~ 22 1800 40/57 1039 PA3515WL 230V~ 33 2600 41/59 1549 PA3520WL 230V~ 42 3200 42/60 2039 PA3525WL 230V~ 59 4600 42/61 2549 *) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC. Future models: Heat output [kW] 0 0 0 0 Length Thermozone PA3500 WL, water heated (IP20) 2 Type 5/6m Heat output [kW] 3,9/7,8/12,0 6,0/12,0/18,0 7,8/15,6/24,0 9,9/19,8/30,0 Airflow Sound level [m³/h] [dB(A)] 2700 46/64 3700 46/64 5300 47/65 6350 49/67 Length [mm] 1039 1549 2039 2549 Thermozone PA4200 WL, water heated (IP20) 2 Type Voltage Heat Airflow Sound Length output* level [V] [kW] [m³/h] [dB(A)] [mm] PA4210WL 230V~ 31 2700 46/64 1039 PA4215WL 230V~ 45 3700 46/64 1549 PA4220WL 230V~ 64 5300 47/65 2039 PA4225WL 230V~ 79 6350 49/67 2549 *) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC. Recessed mounting in false ceiling PA3XT/PA4XT, outlet extension Outlet extension with telescopic function. Used for recessed installation of units in suspended ceilings. Horizontal mounting PA34WB, wall brackets Brackets for installing unit horizontally on a wall. PA34CB, ceiling brackets Ceiling brackets for installing the unit from the ceiling using wires or threaded bars (not included). Best combined with vibration dampers (PA34VD) when using threaded bars. PA34WS, wire suspension kit Galvanized wires with wire locks to secure the unit from the ceiling. Used together with ceiling brackets (PA34CB). Control options This air curtain is supplied with an intregrated PC board SIRe. SIRe is an intelligent and well designed low voltage control system which can be customised for each unique application and environment. SIRe is supplied pre-programmed with quick fit plug connections and is very easy to use and install. If more than one air curtain should be controlled by a single SIRe, an additional modular cable SIReCC per unit is needed. Cables between units can easily be joined together by using joint piece SIReCJ. There are three different levels with different functionality to choose from, Basic, Competent or Advanced. Valve kit VOS(P), VOT, VMO(P) or VMT is used to control the water flow, see final section of this catalogue. A i r cur t ai ns Air curtains - Thermozone® Industry PA34TR, threaded bars Threaded bars for installing unit on to a ceiling. Used together with ceiling brackets (PA34CB). Supplemented with vibration dampers (PA34VD) for reduced vibration. PA3JK/PA4JK, joining kit Used to join horizontal units together for a sleek and unified installation. Consists of joint bracket and mounting parts. PA3DW/PA4DW, design kit for wall mounting Gives a neater installation on the wall by covering mountings, cables and pipes. Used together with wall brackets PA34WB. PA3DC/PA4DC, design kit for ceiling mounting Gives a neater installation on the ceiling by covering mountings, cables and pipes. Consists of start parts, intermediate parts and telescopic parts for attachment to ceilings. The design kit can also be used for non-recessed mounting in suspended ceilings, telescopic parts are however not then needed. The kit can be combined with any type of ceiling mounting (wires, rods, etc.) No start parts are needed for PA4200. For more information about the design kit, see www.frico.se. Vertical mounting PA3JK/PA4JK, vertical kit Used to adapt a horizontal unit for a vertical installation. Consists of floor edging, mounting parts and bracket to brace the top of the unit. The edging is also used as a joint bracket making it possible to mount two units on top of each other. PA3VDW/PA4VDW, design kit for vertical mounting Gives a neater vertical installation by covering cables and pipes. PA3HE/PA4HE, extension hood Fills the space between the unit and the ceiling for vertical mounting and provides a neater installation. Special order to required dimension. Horizontal and vertical mounting PA34EF, external intake filter Fine mesh filter that prevents ingress of dirt and deposits to the unit. The filter is easy to attach and remove thanks to the integrated magnetic strips. Makes maintenance easier since the unit does not need to be opened. FHDN20, flexible hoses Flexible hoses for easy and practical installation of water heated unit. Accessories - PA3500/4200A/E/W Type Description SIReB SIReAC SIReAA PA34WB15 PA34WB20 PA34WB30 PA34CB15 PA34CB20 PA34CB30 PA34WS15 PA34WS20 PA34WS30 PA34TR15 PA34TR20 PA34TR30 PA34VD15 PA34VD20 PA34VD30 PA3JK PA4JK PA3DW10 PA3DW15 PA3DW20 PA3DW25 PA4DW10 PA4DW15 PA4DW20 PA4DW25 PA3XT10 PA3XT15 PA3XT20 PA3XT25 PA4XT10 PA4XT15 PA4XT20 PA4XT25 PA3JK PA4JK PA3VDW15 PA3VDW20 PA3VDW25 PA4VDW15 PA4VDW20 PA4VDW25 PA3HE PA4HE PA34EF10 PA34EF15 PA34EF20 PA34EF25 FHDN20 Control system SIRe Basic Control system SIRe Competent Control system SIRe Advanced Wall brackets for PA3510/3515/4210/4215 Wall brackets for PA3520/4220 Wall brackets for PA3525/4225 Ceiling brackets for PA3510/3515/4210/4215 Ceiling brackets for PA3520/4220 Ceiling brackets for PA3525/4225 Wire suspension kit for PA3510/3515/4210/4215 Wire suspension kit for PA3520/4220 Wire suspension kit for PA3525/4225 Threaded bars for PA3510/3215/4210/4215 Threaded bars for PA3520/4220 Threaded bars for PA3525/4225 Vibration dampers for PA3510/3515/4210/4215 Vibration dampers for PA3520/4220 Vibration dampers for PA3525/4225 Joining kit PA3500 Joining kit PA4200 Design kit for wall mounting PA3510 Design kit for wall mounting PA3515 Design kit for wall mounting PA3520 Design kit for wall mounting PA3525 Design kit for wall mounting PA4210 Design kit for wall mounting PA4215 Design kit for wall mounting PA4220 Design kit for wall mounting PA4225 Outlet extension for PA3510, 130-200 mm Outlet extension for PA3515, 130-200 mm Outlet extension for PA3520, 130-200 mm Outlet extension for PA3525, 130-200 mm Outlet extension for PA4210, 130-200 mm Outlet extension for PA4215, 130-200 mm Outlet extension for PA4220, 130-200 mm Outlet extension for PA4225, 130-200 mm Vertical kit for PA3500 Vertical kit for PA4200 Design kit for vertical mounting PA3515 Design kit for vertical mounting PA3520 Design kit for vertical mounting PA3525 Design kit for vertical mounting PA4215 Design kit for vertical mounting PA4220 Design kit for vertical mounting PA4225 Extension hood for PA3500 Extension hood for PA4200 External intake filtre for PA3510/4210 External intake filtre for PA3515/4215 External intake filtre for PA3520/4220 External intake filtre for PA3525/4225 Flexible hoses DN20, inside thread, 90° bend 23 Air curtains - Thermozone® Industry Thermozone® AG4500/5000A/W Accessories - AG4500/5000A/W Installation height up to 5 metres. Clean, stylish and simple design. Height: 450 mm Depth: 750 mm Colour: white, RAL 9016. CE compliant. 5m Type 1/1,5/2/2,5m Thermozone AG4500/5000A, ambient, unheated (IP23) Type Voltage AG4515A AG4520A AG4525A AG5010A AG5015A AG5020A AG5025A [V] 230V~ 230V~ 230V~ 230V~ 230V~ 230V~ 230V~ Heat output [kW] 0 0 0 0 0 0 0 Airflow [m³/h] 5300 7600 10200 4700 7100 9300 11600 Sound level [dB(A)] 48/67 50/69 51/70 48/67 50/69 51/70 52/71 1 Length [mm] 1500 2000 2500 1000 1500 2000 2500 Control kits AG4500/5000A 1 Level 1 CB30N, controls the airflow in 3 steps Level 2 CB30N and MDC, magnetic door contact with time relay Description Control kit Water level 1 (CB30N, T10) Control kit Water level 2 (CB30N, RTI2, MDC) Control kit level 3 (ADEA, ADEAIS, ADEAEB, ADEAGD1) Control box (A/W) Control box (E) Air curtain control External control board, IP55 External room sensor, IP30 Additional control board to acheive ADEA and BMS functionality RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 AGB304 Door contact, IP44 KUR Digital time switch, IP55 CBT Electronic timer, IP44 VR20 Valve set, DN 20 mm VR25 Valve set, DN 25 mm TVV20 2-way control valve, DN 20 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator GWB640 Wall bracket. AG4510/4515 and AG5010/5015 require 2 pcs. AG4520/AG4525 and AG5020/AG5025 require 3 pcs. More information about accessories on pages 30-31 and 62-66. CK01W CK02W CK03GD CB30N CB32N ADEA ADEAEB ADEAIS ADEAGD1 Product specific accessories, AG4500/5000 Thermozone AG4500/5000W, water heated (IP23) Type 2 Voltage Heat Airflow Sound Length output* level [V] [kW] [m³/h] [dB(A)] [mm] AG4515WL 230V~ 44 4800 48/67 1500 AG4520WL 230V~ 71 7000 50/69 2000 AG4525WL 230V~ 92 9400 51/70 2500 AG5010WL 230V~ 43 4200 48/67 1000 AG5015WL 230V~ 56 6500 50/69 1500 AG5020WL 230V~ 81 8500 51/70 2000 AG5020WL 230V~ 100 10600 52/71 2500 *) Applicable at water temperature 80/60 °C, air temperature, in +15 ºC. Control kits AG4500/5000W 2 CK01W CB30N, controls the airflow in 3 steps Level 1 T10, room thermostat CK02W Level 2 CB30N and RTI2, 2-step room thermostat MDC, magnetic door contact with time relay CK03GD Level 3 ADEA, air curtain control with outdoor sensor, built-in room sensor and door contact ADEAIS, external room sensor ADEAEB, external control board ADEAGD1, extra control board Note! A valve set VR20/25 (option: TVV20/25 with SD20) should be added for a complete control kit. 24 Conditions for sound level measurements, see page 67. GWB, wall bracket The brackets are screwed into place in the wall. The air curtain is then suspended from the brackets using threaded bars. 2 brackets are needed for units up to 1,5 metres and 3 brackets are needed for 2 and 2,5 metre units. 4-8 m A i r cur t ai ns Air curtains - Thermozone® Industry 3-8 m UF600 Installation height 3 - 6 metres. Can also be mounted vertically. Without heat. Height: 785 mm Depth: 520 mm Colour: white, RAL 9016. CE compliant. UF600 consists of one or two pillars with inlet hood, silencers and fans, as well as a floor channel with its slot at floor level. The pillars are placed inside or outside the door on either (or both) sides of the opening. Air at high speed is pressed out through the narrow slot in the floor at the door opening. The width of the slot and the blow angle are adapted to the opening. Complete slot with inspection hatch could be custom made. UF600 creates a very effective air barrier at the door opening, when pressing air at high speed out through a narrow slot. The air curtain is angled upwards and gives best possible protection against colder and heavier air getting into the building. Diameter: 700/900 mm Colour: grey. CE compliant. 3-6 m Thermozone® AC500 1 / 1,5 m Thermozone AC500, ambient, unheated (IP24) Type AC501 AC502 Voltage Heat output [V] [kW] 230V~/400V3~ 0 230V~/400V3~ 0 Airflow [m³/h] 5200 7700 1 Sound level [dB(A)] 63 65 Length [mm] 1030 1550 Control kits AC500 1 Level 1 AGB304, door contact, starts/stops the air curtain when the door is opened/closed RTRD7, RTRD14, 5-step fan speed control Level 2 AGB304 and PKDM12, stepless fan speed control, high/low speed Accessories - AC500 Type Description RTRD7 5-step fan speed control, Max 7 A RTRD14 5-step fan speed control, Max 14 A RTRDU7 5-step fan speed control, high/low speed PKDM12 Stepless fan speed control, high/low speed AGB304 Door contact, IP44 More information about accessories on pages 30-31 and below. UF600, ambient, unheated (IPX4) Type Voltage [V] UF601 400V3~ UF602 400V3~ UF603 400V3~ UF604 400V3~ UF605 400V3~ UF606* 400V3~ *) UF606 consists of two pillars. 1 Max door dimensions HxW [m] 3x4 3x6 4x5 4x6 6x6 5x8 Control UF600 1 For more information please visit www.frico.se. Product specific accessories, AC500 PKDM12, 3-phase stepless fan speed control The appropriate fan speed is set for open and closed door respectively (high/low speed). The fan speed can be controlled with an external 0–10 V signal. Max input 12 A. IP54. Conditions for sound level measurements, see page 67. 25 1,2 / 1,8 / 2,4 / 3,0 m Air curtains - Thermozone® Industry Thermozone® AGI A/W 1,2 / 1,8 / 2,4 / 3,0 m Thermozone AGI is a robust air curtain for industrial doors that can be mounted horizontally or vertically. Four module lengths means you can easily combine the curtains to cover the individual needs of every door. An adjustable air blower grille allows you to direct the airflow to achieve an optimal air curtain effect. Width: 730 mm Depth: 490 mm Colour: grey, RAL 9006. CE compliant. Thermozone AGI W, water heated, vertical mounting, (IP54) Type Heat Airflow Sound Height output* level [V] [kW] [m³/h] [dB(A)] [mm] AGIV2WL 400V3~ 50 7000 69 1200 AGIV3WL 400V3~ 77 10500 71 1800 AGIV4WL 400V3~ 106 14000 72 2400 AGIV5WL 400V3~ 132 17500 73 3000 *) Applicable at water temperature 80/60 °C, air temperature, in +15 ºC. Thermozone AGI A, ambient, unheated, vertical mounting, (IP54) 1 Type Voltage AGIV2A AGIV3A AGIV4A AGIV5A [V] 400V3~ 400V3~ 400V3~ 400V3~ Heat output [kW] 0 0 0 0 Airflow [m³/h] 7000 10500 14000 17500 Sound level [dB(A)] 69 71 72 73 Height [mm] 1200 1800 2400 3000 Thermozone AGI A, ambient, unheated, horizontal mounting, (IP54) 1 Type Voltage AGIH2A AGIH3A AGIH4A AGIH5A [V] 400V3~ 400V3~ 400V3~ 400V3~ Heat output [kW] 0 0 0 0 Airflow [m³/h] 7000 10500 14000 17500 Sound level [dB(A)] 69 71 72 73 Length [mm] 1200 1800 2400 3000 Control kits AGI A 1 Level 1 AGB304, door contact, starts/stops the air curtain when the door is opened/closed RTRD7, RTRD14, 5-step fan speed control 26 2 Voltage Conditions for sound level measurements, see page 67. Thermozone AGI W, water heated, horizontal mounting, (IP54) 2 Type Voltage Heat Airflow Sound Length output* level [V] [kW] [m³/h] [dB(A)] [mm] AGIH2WL 400V3~ 56 7000 69 1200 AGIH3WL 400V3~ 86 10500 71 1800 AGIH4WL 400V3~ 118 14000 72 2400 AGIH5WL 400V3~ 147 17500 73 3000 *) Applicable at water temperature 80/60 °C, air temperature, in +15 ºC. Control kit s AGI W 2 Level 1 RTRD7, RTRD14, 5-step fan speed control T10, room thermostat Level 2 RTRD, T10 and MDC, magnetic door contact with time relay Accessories - AGI A/W Type Description RTRD7 5-step fan speed control, Max 7 A RTRD14 5-step fan speed control, Max 14 A RTRDU7 5-step fan speed control, Max 7 A, high/low speed T10 Room thermostat, IP30 KRT1900 Room thermostat, IP55 MDC Magnetic door contact with time relay, IP44 AGB304 Door contact, IP44 KUR Digital time switch, IP55 CBT Electronic timer, IP44 VR25 Valve set, DN 25 mm TVV25 2-way control valve, DN 25 mm SD20 Actuator More information about accessories on pages 30-31 and 62-66. Our cool models Frico offers several models without heat that are suitable for keeping the cold in cold storages. Choose the appropriate unit according to the dimensions of the opening. There are units for horizontal and vertical mounting and in different designs. Thermozone® ADA Cool Horizontal mounting For cold storage openings. Installation height up to 2,5 metres. Suitable where space is limited between the ceiling and the upper edge of the doorway. With cable and plug. Should be mounted on the outside (warm side). ADAC has a simple connection making it possible to link units together in order to cover wide openings such as open cold storages. All connections are done with cable and plug, including the control. Recessed mounting possible. Height: 235 mm Depth: 215 mm Colour: white, RAL 9016. CE compliant. Installation height up to 2,5 m A i r cur t ai ns Air curtains - Thermozone® Cold storage 2,5 m ADA Cool AD200A Lengths: 1, 1,5 and 2 metres. AD200 0,9 / 1,2 m Installation height up to 3,5 m PA3500A Lengths: 1, 1,5, 2 and 2,5 metres. AD300A Lengths: 1, 1,5 and 2 metres. AD300/400 Thermozone ADA Cool, ambient, unheated (IP22) Type Voltage ADAC090 ADAC120 [V] 230V~ 230V~ Heat output [kW] 0 0 Airflow [m³/h] 1150 1400 1 Sound level [dB(A)] 54 51 Length [mm] 900 1200 Description ADACR 5-step fan speed control AD400A Lengths: 1, 1,5 and 2 metres. Installation height up to 4,2 m Accessories - ADA Cool Type Installation height up to 4 m PA3500/4200 PA4200A Lengths: 1, 1,5, 2 and 2,5 metres. Installation height up to 5 m Product specific accessories, ADA Cool AG4500A and AG5000A Lengths: 1, 1,5, 2 and 2,5 metres. 2,2 m ADACR, 5-step fan speed control ADACR is a control and connection set consisting of a 5-step fan speed control, flexible cable and earthed plug. Can control a maximum of 7-9 units (max. 7 units at 60 Hz). Max input: 5 A. Dimensions: 200x105x105 mm. IP30. ADACR 5A AG4500/5000 Vertical mounting Installation width up to 3,5 m 2,2 m PA3500A Heights: 1,5, 2 and 2,5 metres. Installation width up to 4,2 m PA4200A Heights: 1,5, 2 and 2,5 metres. PA3500/4200 Conditions for sound level measurements, see page 67. 27 Air curtains - Thermozone® Controls SIReB Basic SIReAC Competent ur e m rat ste pe -sy em MS rn xl im it o fr e tu Ad v an ce wa te rt dB er ti v Pro ac Co mf eg ort ula mo tio n de e od om sy SBM ple Ec ste m rm ala Sim un rf da Ca len Fil te r cti on de en Op xib Fle mo e od le m mo tic ma Au to Ma nu al op era tio n de SIReAA Advanced SIRe is an intelligent and well designed low voltage control system which can be customised for each unique application and environment. SIRe is supplied pre-programmed with quick fit plug connections and is very easy to use and install. The control system is pre-installed in air curtains PA3500, PA4200, AR3500 and AD Corinte with an integrated PC board. SIRe learns the requirements in the entrance it is installed in (e.g. opening frequency and outdoor temperature). It has calendar function and selectable switch off at set temperatures for up to nine units. Because the fan speed is adapted, the sound level is optimised and is never higher than is necessary for comfort. With SIRe Advanced it is possible to choose between Eco and Comfort mode dependent on whether energy savings or optimal comfort has been prioritised. There are three different levels with different functionality to choose from, Basic, Competent or Advanced. Functions SIReB Basic •Manualregulationofthefanandtemperature •Automaticcontroloffanspeedandtemperaturewith integrated thermostat. Functions SIReAC Competent •AllfunctionsforBasic •Calendarfunction •Filteralarm •SimpleBMScontrol-on/off,fanspeedandalarmfunctions •Flexiblemode-fordoorsthatopenandclosefrequently •Openmode-fordoorsthatstayopen Functions SIReAA Advanced •AllfunctionsforCompetent •Ecomode-extraenergy-efficientmode •Comfortmode-whencomfortisimportant •AdvancedBMScontrol •Proactiveregulation–measuresoutdoortemperaturesfor proactive reaction. 28 Ma Control system SIRe Included in SIReB Basic: •SIReB1,integratedPCboardBase •SIReIT,internaltemperaturesensor •SIReUB1,controlunit.Wallunitcoverincluded. •SIReCC,modularcable,RJ12(6/6),5m Options: •SIReRTX,externalroomtemperaturesensor •VOS(P),(pressureindependent)valvekiton/offorVOT,three way valve and actuator on/off Included in SIReAC Competent: •SIReB1,integratedPCboardBase •SIReIT,internaltemperaturesensor •SIReUA1,controlunit.Wallunitcoverincluded. •SIReC1X,PCboardHUBCompetent •SIReDC,doorcontact •SIReCC,modularcables,RJ12(6/6),3mresp.5m Options: •SIReRTX,externalroomtemperaturesensor •SIReUR,kitforrecessedinstallation •VOS(P),(pressureindependent)valvekiton/offorVOT,three way valve and actuator on/off Included in SIReAA Advanced: •SIReB1,integratedPCboardBase •SIReIT,internaltemperaturesensor •SIReUA1,controlunit.Wallunitcoverincluded. •SIReA1X,PCboardHUBAdvanced •SIReOTX,outdoortemperaturesensor •SIReDC,doorcontact •SIReCC,modularcables,RJ12(6/6),3mresp.5m Options: •SIReRTX,externalroomtemperaturesensor •SIReUR,kitforrecessedinstallation •SIReWTA,clamp-onsensor •VMO(P),(pressureindependent)modulatingvalvekitor VMT, three way valve and modulating actuator Air conditioner control Building Management System SIReDC A i r cur t ai ns Air curtains - Thermozone® Controls Elevator control Fire alarm system SIReRTX/OTX SIReUR SIReWTA Entrance control Air curtain control Integration of air curtains AR3500, AD Corinte, PA3500 and PA4200 in an overall control system (BMS) BMS-control - level 1 With SIRe Competent the above air curtains can be integrated in an overall control system (BMS). The air curtain can be started/stopped and the fan speed regulated via the BMS system. A 5-30V control signal is required for starting/stopping. A 0-10V control signal is required to control the fan speed. Potential free contact for buzzer. BMS-control - level 2 With SIRe Advanced the above air curtains can be integrated in an overall control system (BMS). The air curtain can be started/stopped, the fan speed and heating regulated smoothly via the BMS system. A 5-30V control signal is required for starting/stopping. A 0-10V control signal is required to control the fan speed and heating. Input for alarm and night reduction via external potential free contact. Potential free contact for buzzer and operation indication. BMS-control - level 3 With SIRe Advanced it is also possible to communicate via Modbus RTU (RS485). Contact Frico for more information. Control system SIRe Type Description SIReB SIReAC SIReAA Control system SIRe Basic Control system SIRe Competent Control system SIRe Advanced Accessories - SIRe Type Description SIReRTX SIReUR SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 External room temperature sensor Kit for recessed installation Clamp-on sensor Used to join two RJ11(4/4) Used to join two RJ12 (6/6) Modular cable RJ12 3 m Modular cable RJ12 5 m Modular cable RJ12 10 m Modular cable RJ12 15 m Modular cable RJ11 3 m Modular cable RJ11 5 m Modular cable RJ11 10 m Modular cable RJ11 15 m SIReCC610 SIReCC615 SIReCC403 SIReCC405 SIReCC410 SIReCC415 Water control Valve kit VOS(P), VOT, VMO(P) or VMT is used to control the water flow, see final section of this catalogue. 29 Air curtains - Thermozone® Controls ADEA CB22/ CB32N ADSR54 CB30N RTRD7 RTRD14 RTRDU7 ADEA, air curtain control ADSR54, stepless fan speed control For Portier, AD, ACC, AG. An outdoor sensor, room sensor and door contact govern the control, which adapts the heat and fan speed, according to the preset parameters, to the prevailing conditions. In its basic design the fan speed is controlled in 3 steps, but can, via a 0-10 V signal, govern an external controller (ADSR54 or frequency inverter) to provide fully variable control. A control board needs to be added, ADEAIB for internal mounting (for AD300/400 only) or ADEAEB (IP55) for external mounting (for all units). Depending on the motor current, one or more units may be controlled with one control board. An extra control board ADEAGD1 is needed to control AG and ACC air curtains. The control board also makes it possible to connect any Frico air curtain running with ADEA to an advanced BMS system. For AD200/300/400 A/W. For unheated and water heated air curtains (single phase supply 230 V~, max 3 A). Controls the motor without causing disturbing electro magnetic noise. Can be controlled with an external 0–10 V signal. Max. input 3 A, 230 V~. IP54. RTRD7, 5-step fan speed control For AC500 and AGI. With RTRD7 the air velocity is adjusted in 5 steps for optimum efficiency. The air velocity is set to accommodate different external conditions. Max input 7 A. IP21. RTRD14, 5-step fan speed control For AC500 and AGI. With RTRD14 the air velocity is adjusted in 5 steps for optimum efficiency. The air velocity is set to accommodate different external conditions. Max input 14 A. IP21. CB22, control box For Portier. Controls the airflow in 2 steps and heat output in 2 steps. CB22 is used for electrically heated units. Can control several units. Max input 10 A. IP44. RTRDU7, 5-step fan speed control (high/low speed) For AC500 and AGI. With RTRDU7 the air velocity is set in 5 steps for maximum efficiency. When the door is closed the fan runs at a preset low speed to keep the room warm, when the door is open the fan is preset at a high speed to accommodate different external conditions. Max input 7 A. IP21. CB20, control box For Portier. Controls the airflow in 2 steps. CB20 is used for unheated units. Can control several units. Max input 10 A. IP44. CB32N, control box For AD E, AR200 E, AG E, AC Corinte E, SF E and RD E. Controls the airflow in 3 steps and heat output in 2 steps. CB32N is used for electrically heated units. Can control several units. Max input 10 A. IP44. CB30N, control box For AD A/W, AR200 A/W, AG A/W, AC Corinte W, SF W and RD W. Controls the airflow in 3 steps. CB30N is used for unheated and water heated units. Can control several units. Max input 10 A. IP44. Portier A ADEA Air curtain control E A E AD 200/300/400 W A X E W X X SF, RD E W AC Corinte AG4500/5000 A E W X X ADEAOS Outdoor sensor X X X X X ADEAEB External control board X X X X X ADEAIB Internal control board X *¹ X*¹ ADEAIS External room sensor X X X X X ADEAGD1 Extra control board for ADEAEB, BMS X X X X*2 X*2 AC500 AGI A W CB20 Control box CB22 Control box X CB30N Control box CB32N Control box ADSR54 Stepless fan speed control RTRD7 5-step fan speed control X X RTRD14 5-step fan speed control X X X X X RTRDU7 5-step fan speed control *¹) only for AD300/400. *²) ADEAGD1 is required when ADEA is used with these products. *3) Max.input 3A. 30 AR200 X X X X X X X*3 X X X X X X*3 A i r cur t ai ns Air curtains - Thermozone® Accessories ADPF ADPK1 4x 2x MDC MDCDC AGB304 22003, 22004 AXP300 MDC, magnetic door contact with time relay 22003, 22004, false ceiling grille Starts the air curtain or increases from low to high speed when the door is opened. When the door is closed, the fan continues to run for the preset time (2 s–10 min). Prevents the fan from starting/stopping continuously and is especially suitable for doors that are frequently opened. Three alternating volt-free contacts 10 A, 230 V~. Is activated by a volt-free make. A MDCDC is included in MDC. IP44. For AD200/300/400. Primarily used as air inlet grille when the air curtain is recessed into a false ceiling. Available in two sizes; 1192x192 mm and 1515x192 mm. Colour: white. ADPK1, suspension kit For AD200/300/400 and Portier. Mounting kit for suspension mounting of the AD-range. Consists of 2 hanging brackets, length 1 metre, and 4 bracket fixtures, 2 for the unit and 2 for the ceiling. The hanging brackets are covered by a white plastic trim to cover the cables. The brackets may be cut to shorter length, if required. Note! The 2-metres AD-units need 3 fixing points. Colour: white. MDCDC, magnetic door contact Indicates door status. Extra MDCDC are used when several doors are connected to a MDC. IP44. AGB304, door contact Starts the air curtain or activates a fan speed control when the door is opened. When the door closes, AGB304 stops the air curtain or changes fan speed through a fan speed control. Alternating contact 4 A, 230 V~. IP44. ADPF1, suspension brackets For AD200/300/400 and Portier. Suspension brackets for the AD-range. Consists of 4 brackets, 2 for the unit and 2 for the ceiling. Note! The 2-metres long AD-units need 3 fixing points. Colour: white. AXP300, collision protection AXP300ismountedonthegroundnexttoaverticalaircurtain to prevent it from being hit by trucks, shopping trolleys and similar. Colour: metal grey. Portier MDC AC Corinte AR200 AD 200/300/400 RD, SF E E W A E W A E W E W A E W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AGB304 22003 22004 ADPK1 X ADPF1 X AXP300 AG4500/5000 X X X AC500 A AGI A UF600 W A X X X X X X 31 Radiant heaters Heating with radiant heaters is indirect. The heat is transferred from the radiant heaters at the ceiling to surfaces such as floors, walls, fixtures and the like, which in their turn give off heat to the air in the room. No losses occur on the way from ceiling to floor. Radiant heating can be compared to ordinary light. Dispersion and reflection occur in relatively the same way. Radiant heaters create a very equal temperature distribution between floor and ceiling. The expensive cushion of overheated air that is easily formed when using other heating systems can be avoided. In rooms with high ceilings, radiant heaters give significantly lower energy consumption. Total heating Radiant heaters heat people first, then the air. The operative temperature, being the temperature a person senses, is therefore a little higher than the actual air temperature. For a specific comfort level, use of a radiant heating system will allow a reduction in air temperature of a couple of degrees when compared to a conventional system, and every degree reduction will reduce energy consumption by approx. 5 %. Zone and spot heating There are many advantages with radiant heaters: Economy • Heatpeopleandobjectsfirstandthenthesurrounding air. This allows the temperature to be reduced while maintaining comfort. • Producesinstantheat,thusmuchquickerthan traditional heating systems. This is especially useful outdoor and in buildings that is used occasionally such as sport centres and country houses. • Heatatfloorlevel,notattheceiling. • Reducednighttemperturepossiblewithrightcontrols thanks to quick heat-up time. With a radiant heating system, different zones within the same room can have different temperatures. It is therefore possible to divide any area into smaller zones and maintain a different comfort level in each zone. It is also possible to focus the heat on a certain spot, such as a single workstation. A spot heating application can be controlled much as spot lighting, with the level of heating being increased when needed. Safety Complementary heating Simplicity As addition to other heating systems and when expanding an existing system, radiant heaters are often a simple, inexpensive solution. For a water heated building, putting up a single or a few electrical heaters is often a smoother and more flexible solution than extending the water pipe system. Cold draught protection A cool surface such as a window has a chilling effect on the neighbouring air. Radiant heaters provide efficient and economical protection against cold draughts caused by windows by heating the window’s surface. The colder the window, the more radiant heat it will draw. The radiated heat ”automatically” migrates to where it is most needed, which facilitates the creation of a comfortable indoor climate. • Bypositioningtheheatersathighleveltheriskofgetting in contact with the heater is greatly reduced. The heater is also protected against damage. • Someradiantheatersareidealforpremiseswithfirerisk or highly explosive environments (see radiant heaters ComfortPanelSZandSZR). • Easyandflexibleinstallation. • Requiresaminimumofmaintenance. Space • Byputtingtheheaterontheceiling,valuablewalland floor space is saved. Comfort • Usingtheradiationprincipleairisnotheateddirectly. This results in a soft, draught-free, comfortable indoor climate and an even temperature. • Doesnotcauseanyairmovement,astraditional heating systems often do. Reducing the spread of dust, bacteria or odours improves the quality of the indoor environment. Discreet • Thesystemiscompletelysilent. • Mountingontheceilingorrecessedinafalseceiling gives a discreet heating. 32 Choose the right radiant heater Radiant heaters are available in various designs – it is primarily the installation height, the surrounding environment and the type of heating wanted (see previous page)thatdeterminethechoiceofproduct. Our radiant heaters are divided into three main application areas: "Offices, shops and public premises", "Industry and large premises" and "Outdoors" but most of them can be used in several application areas as you can see in below table. Comfort Radiant heaters To acheive good comfort, it is essential to choose the right type of radiant heater. An infrared heater equipped with halogen lamps at approx. 2000 °C provides intense, short-wave radiation. It is well-suited to outdoor use or in rooms with high ceilings. For a similar but softer heat an infrared heater with tube elements at approx. 750 °C can be used. The heat emitted from these radiant heaters can be compared to the radiant heat felt from an open fireplace. A Thermocassette with a large element surface and a surface temperature of approx. 100 °C, provides longwave heat radiation, giving comfortable heating and good dispersioninroomsofnormalheight(2,7m). In a building with high demands on comfort, a larger number of heaters with low output should be used instead of fewer heaters with high output. When zone- or spot heating an area, the heaters should be placed so that the heat comes from at least two directions. This is especially important when the heaters are mounted at lower heights. Belowtableandtheexamplesonthefollowingpageswill help you to choose the right radiant heater. Quick selection guide radiant heaters Type Heating Installation height [m] [W] [°C] Offices Thermoplus 3 3 3 3 3 3 3 3 3 3 2–3 300-900 180 ++ + Radiant aluminium panel 33 <3 300-600 100 ++ + Heating film 34 2,5–4 600-1500 280 ++ + Radiant aluminium panel 34 3–10 800-2200 340 ++ Radiant aluminium panel 35 4–15 3600-4500 350 ++ Radiant aluminium panel 35 4,5–20 3000-6000 700 ++ Infrared heating rod 36 3–5 1500-4500 2200*3 ++ + Halogen lamp 36 2–2,5 500-2000 750 + ++ Infrared heating rod 37 2–3 1200 2200*3 + ++ Halogen lamp 37 1,8–3,5 1000-1500 2200*3 + ++ Halogen lamp 38 3 1,8–3,5 800-3000 1000/1200*3 + ++ Carbon fibre lamp 39 2,5–10 100-580*2 80 Thermocassette Elztrip EZ100 Elztrip EZ200 Elztrip EZ300 Infrared IR Infrared IRCF Infrared CIR Infrared ELIR Infrared IH Carbon Infrared IC Comfort panel SZR 2 2 Output Surface temp. Application area*1 ++ Heating element Page Industry Outdoors + Radiant steel panel 3–15 50-1900*2 80 ++ Radiant steel panel Comfort panel SZ *1) Our products are divided into three main application areas: "Offices, shops and public premises", "Industry and large premises" and "Outdoors" but most products can be used in several application areas. *2) Per metre, depending on water temperature. *3) Filament temperature 40 41 33 Radiant heaters Installation examples for radiant heaters Frico radiant heaters are available for different kinds of heating and for different application areas. To facilitate your choice of product, you will find some typical cases onthefollowingpages.Moredetailedinformationon important factors to consider when choosing a radiant heater is found on the previous pages. Basic criterias: 1. Type of premises – store, warehouse etc. 2. Type of heating - total heating, zone heating, cold draught protection 3.Height,installationheight 4.Mounting:wallorceiling Industry and large premises Offices, shops and public premises 5. Connection: with electrical heat or water heat Total heating, cafeteria 1. Type of premises: cafeteria 2. Type of heating: total heating 3.Height:2,80metres 4.Mounting:ceiling 5. Connection: electrical Recommendation: Thermocassette can be recessed into a false ceiling. When using Thermocassette for total heating, the units should be spread out through the ceiling for example as shown. Total heating, workshop 1. Type of premises: workshop 2. Type of heating: total heating 3.Height:5metres 4.Mounting:ceiling 5. Connection: with electrical heat Recommendation:AnumberofEZ300evenly positioned over the area to be heated creates comfortable heat. Zone heating, restaurant terrace 1. Type of premises: restaurant terrace 2. Type of heating: zone heating 3.Height:3metres 4.Mounting:ceiling(abovethetables) Outdoors 5. Connection: with electrical heat 34 Recommendation:SeveralCIRmountedin line above the tables ensure the comfort for all customers in deep terraces. Radiant heaters - Offices, shops and public premises Thermoplus •Thermoplusisavailableinthreeversions: - Type EC, for dry rooms. Controlled by a separate thermostat or output control. IP20. - Type ECVT, for wet rooms. With a built-in cord switch and thermostat. IP44. - Type ECV, for wet rooms. Primarily designed for connection as slave device to ECVT, but can also be controlled separately using the same methods as for EC. IP44. •Bracketsforwallmountingareincluded.Fixturesforceiling mounting are extra. •Max.surfacetemperature:180°C. •Colour:white,RAL9010,NCS0502-B. •CEcompliant. Thermoplus EC for dry rooms (IP20) Type EC45021 EC45031 EC60021 EC60031 EC75021 EC75031 EC90021 EC90031 Voltage [V] 230V~ 400V~ 230V~ 400V~ 230V~ 400V~ 230V~ 400V~ 3 Heat output [W] 450 450 600 600 750 750 900 900 LxHxD [mm] 1076x100x90 1076x100x90 1505x100x90 1505x100x90 1810x100x90 1810x100x90 2140x100x90 2140x100x90 Weight [kg] 2,6 2,6 3,7 3,7 4,4 4,4 4,8 4,8 Radi an t h e at e r s Thermoplus is mounted above windows and gives an effecient protection against cold draught. The slim shape also makes it 2-3m suitable for heating areas with limited space, like for example bathrooms. Thermoplus can furthermore be a cost-effective and flexible alternative to floor heating. Thermoplus is covered with white enamel which makes it discreet and schratch-resistant. The slim shape makes it practically invisible when mounted in the celing angle. Thermoplus ECVT for wet rooms, with built-in switch and thermostat (IP44) 3 Type ECVT30021 ECVT55021 ECVT55031 ECVT70021 ECVT70031 Voltage [V] 230V~ 230V~ 400V~ 230V~ 400V~ Heat output [W] 300 550 550 700 700 LxHxD [mm] 870x100x90 1505x100x90 1505x100x90 1810x100x90 1810x100x90 Weight [kg] 2,6 4,3 4,3 5,0 5,0 Thermoplus ECV slave unit to ECVT, for wet rooms (IP44) Type ECV30021 ECV55021 ECV55031 ECV70021 ECV70031 Voltage [V] 230V~ 230V~ 400V~ 230V~ 400V~ Heat output [W] 300 550 550 700 700 LxHxD [mm] 870x100x90 1505x100x90 1505x100x90 1810x100x90 1810x100x90 3 Weight [kg] 2,3 4,0 4,0 4,7 4,7 Accessories - Thermoplus Type Description ERP Electric heating control, master, IP20 ERPS Electric heating control, slave, IP20 T10 Room thermostat, IP30 TKS16 Room thermostat with knob and 1-pole main switch, IP30 TD10 Room thermostat with digital display, IP30 KRT1900 Room thermostat, IP55 TF1 Fixtures for ceiling mounting (2 pcs) OS1 Protection net 1070 mm OS2 Protection net 1500 mm For controls, see pages 44 and 62-63. Min. distances EC [mm] Ceiling Wall / long side of the unit (EC) Flammable material/ front side (EC) Flammable material/ lower side (EC) Floor A B C D E 60 25 90 25 1800 35 Radiant heaters - Offices, shops and public premises Thermocassette HP Elztrip EZ100 Thermocassette is intended for discreet heating in offices, bathrooms, schools etc. Designed for either surface or recessed mounting it <3m is well suited for total heating as well as for spot heating of for example a reception desk. Mountedinafalseceilingitiswellprotected against damage and can easily be moved if necessary (model with cable and plug). Recessedmountingmaketheheateranintegralpartofthe ceiling. EZ100isintendedfortotalandsupplementary heating as well as protection against cold draughts from windows in environments such as offices, shops, restaurants etc. EZ100isasinglepanelradiantheaterwith clean and simple design that blends well with electrical fittings. •Thermocassetteisavailableintwoversions: - HP300/600, for false ceiling systems. IP20. - HP305/605, standard model with brackets, approved for rooms where there is risk of fire and recommended for use inagriculturalbuildings.IP55. •Thelowsurfacetemperature(max.100°C)makes Thermocassette well suited for low ceiling heights. There is no risk of burns to the person(s) in this vicinity. •Max.surfacetemperature:100°C. •Colour:white,RAL9016,NCS0500. •ApprovedbySEMKOandCEcompliant. Type HP300 HP600 Voltage [V] 230V~ 230V~ Heat output [W] 300 600 LxHxD [mm] 593x30x593 593x30x1193 Weight [kg] 5,4 10,3 Thermocassette HP with mounting brackets and cable (IP55) Type HP305 HP605 Voltage [V] 230V~ 230V~ Heat output [W] 300 600 LxHxD [mm] 593x30x593 593x30x1193 •Surfacestructureforbestefficiency. •Theheatersareapprovedforserialconnection. •Fixturesforeasymountingontheceilingareincluded. •Bracketforwallmounting(EZMVK)isavailableasan accessory. •Max.surfacetemperature:280°C. •Colour:white,RAL9010,NCS0502-B. •ApprovedbySEMKOandCEcompliant. Elztrip EZ100 (IP44) Type EZ106 EZ111 EZ115 Thermocassette HP for false ceilings, with cable and plug (IP20) 3 3 Weight [kg] 5,8 10,7 3 Voltage [V] 230V~ 230V~ 230V~ Heat output [W] 600 1050 1500 Type Min. distances HP [mm] Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor 36 80 50 50 500 1800 80 50 500 1800 Weight [kg] 3,7 5,4 7,8 Description ERP Electric heating control, master, IP20 ERPS Electric heating control, slave, IP20 CIRT Stepless output control with timer, IP44 T10 Room thermostat, IP30 TKS16 Room thermostat with knob and 1-pole main switch, IP30 TD10 Room thermostat with digital display, IP30 KRT1900 Room thermostat, IP55 EZMVK Wall mounting bracket For controls, see pages 44 and 62-63. Description ERP Electric heating control, master, IP20 ERPS Electric heating control, slave, IP20 T10 Room thermostat, IP30 TKS16 Room thermostat with knob and 1-pole main switch, IP30 TD10 Room thermostat with digital display, IP30 KRT1900 Room thermostat, IP55 74701 Wire mounting kit For controls, see pages 44 and 62-63. LxHxD [mm] 1000x50x150 1500x50x150 2000x50x150 Accessories - EZ100 Accessories - Thermocassette Type 2,5 - 4 m Min. distances EZ100 [mm] Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor A B C D E 50 50 50 500 1800 Elztrip EZ200 Elztrip EZ300 EZ200 is intended for total and supplementary heating as well as protection against cold draughts from windows in environments such as, department stores, assembly halls, industrial premises etc. EZ200 is a double panel radiant heater with clean and simple design that blends well with electrical fittings. EZ300 is intended for total and supplementary heating in industrial environments such as warehouses, workshops etc. EZ300 is a triple panel radiant heater with discreet and robust design that blends well with electrical fittings. 3 - 10 m Type EZ208 EZ212 EZ217 EZ222 EZ20831 EZ21231 EZ21731 EZ22231 Elztrip EZ300 (IP44) 3 Voltage [V] 230V~ 230V~ 230V~ 230V~ 400V2~ 400V2~ 400V2~ 400V2~ Heat output [W] 800 1200 1700 2200 800 1200 1700 2200 LxHxD [mm] 683x64x282 923x64x282 1221x64x282 1520x64x282 683x64x282 923x64x282 1221x64x282 1520x64x282 Weight [kg] 4,9 6,8 8,8 10,7 4,9 6,8 8,8 10,7 Accessories - EZ200 Type 4 - 15 m •Surfacestructureforbestefficiency. •Theheatersareapprovedforserialconnection. •Fixturesforeasymountingontheceilingareincluded. •Max.surfacetemperature:350°C. •Colour:Casingofgreyalu-zinccoatedsteelpanelswithhigh corrosion resistance. Heating panel of naturally anodised aluminium. •ApprovedbySEMKOandCEcompliant. •Surfacestructureforbestefficiency. •Theheatersareapprovedforserialconnection. •Fixturesforeasymountingontheceilingareincluded. •Max.surfacetemperature:340°C. •Colour:white,RAL9016,NCS0500. •ApprovedbySEMKOandCEcompliant. Elztrip EZ200 (IP44) Radi an t h e at e r s Radiant heaters - Industry and large premises Description Type EZ336 EZ345 3 Voltage [V] 230V3~/400V3N~ 230V3~/400V3N~ Heat output [W] 3600 4500 LxHxD [mm] 1670x63x420 2030x63x420 Weight [kg] 20 24 Accessories - EZ300 Type Description S123 Manual switch for 1-2-3 steps, IP42 T10 Room thermostat, IP30 TK10 Room thermostat with knob, IP30 KRT1900 Room thermostat, IP55 CBT Electronic timer, IP44 For controls, see pages 44 and 62-63. ERP Electric heating control, master, IP20 ERPS Electric heating control, slave, IP20 CIRT Stepless output control with timer, IP44 T10 Room thermostat, IP30 TKS16 Room thermostat with knob and 1-pole main switch, IP30 TD10 Room thermostat with digital display, IP30 KRT1900 Room thermostat, IP55 For controls, see pages 44 and 62-63. Min. distances EZ200 [mm] Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor A B C D E Min. distances EZ300 [mm] 80 150 150 600 1800 Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor A B C D E 115 250 250 700 1800 37 Radiant heaters - Industry and large premises Industrial infrared heater IR Halogen infrared heater IRCF IRissuitabefortotalorsupplementaryheating of premises with large volume and high ceilings. It can also be used outdoors for example on sport arena stands or to keep loading bays dry and frostless. IRhasarobustindustrialdesign. IRCFisespeciallydesignedforspotheating of premises with large air volumes, such as churches, aircraft hangars and marquees. With itshighefficiencyandcompactsizeitisperfect for many difficult applications. IRCFhasadiscreetandcompactdesign. Equipped with one to three halogen lamps and with glossy finished reflectors. 4,5 - 20m •Reflectorsofshinyanodisedaluminiumfor optimal heat distribution. •Themountinghingesallowtheheatertobeangledinfive different positions. •Max.surfacetemperature:700°C. •Colour:Casingofgreyalu-zinccoatedsteelpanelswithhigh corrosion resistance. •ApprovedbySEMKOandCEcompliant. Industrial infrared heater IR (IP44) 3 Voltage Heat output LxHxD Weight [V] [W] [mm] [kg] IR3000 400V3N~* 3000 1125x83x358 9,0 IR4500 400V3N~* 4500 1500x83x358 11,1 IR6000 400V3N~* 6000 1875x83x358 13,2 *) Can be connected without neutral, but then without output steps. With neutral, one elements at a time can be connected. 3 - 10 m •Equippedwithonetothreehalogenlampsandwithglossy finished reflectors. •Easymountingwithmountingbracketonthewallorceiling. The heater can be angled. •Protectiongrilleavailableasanaccessory. •Max.elementtemperature:2200°C. •Colour:grey,RAL9006. •CEcompliant. Type Accessories - Industrial infrared heater IR Type Description Type Min. distances IR [mm] 3 Voltage [V] 230V~ 230V~ 230V~/400V3~ IRCF1500 IRCF3000 IRCF4500 Heat output [W] 1500 3000 4500 HxWxD [mm] 490x230x140 490x375x140 490x515x140 Description Manual switch for 1-2-3 steps, IP42 Electronic timer, IP44 Electronic thermostat with concealed knob Electronic thermostat with visible knob Capillary room thermostat, IP55 Extra lamp Protection grille for IRCF1500. IRCF3000 require 2 pcs, IRCF4500 require 3 pcs. For controls, see pages 44 and 62-63. S123 CBT T10 TK10 KRT1900 LIRCF IRCG1 Min. distances IRCF [mm] A B C D E 400 400 400 700 2300 A A B B C C Ceiling Wall Floor 38 Weight [kg] 2,0 2,5 3,0 Accessories - IRCF Type S123 Manual switch for 1-2-3 steps, IP42 T10 Room thermostat, IP30 TK10 Room thermostat with knob, IP30 KRT1900 Room thermostat, IP55 CBT Electronic timer, IP44 IRG3000 Protection grille IR3000 IRG4500 Protection grille IR4500 IRG6000 Protection grille IR6000 For controls, see pages 44 and 62-63. Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor Infrared heater IRCF (IP20) A B C 500 50 2300 Ceiling Wall Floor A B C 180 500 2300 Infrared heater CIR Halogen infrared heater ELIR CIRprovidecomfortallyeararoundon terraces, balconies and open-air restaurants. CIRcanalsobeusedforspotheatingin workshopsandwarehouses.Requiresno protection against bad weather and has fiveyear corrosion warranty. CIRisdiscreetwithitsslimdesignand silent, invisible operation and needs little space to fit in. ELIRgivesanintenseheatsuitable for all outdoor applications and rough industrialpremises.WhileELIRislight, 2-3 m stable and portable it is also well suited for temporary heating on building sites etc. With its concentrated heat it is a good complement to dehumidifiers for drying in areas damaged by water. High protection class(IP65)makesitpossibletoinstallthe heater in almost any environment. ELIRhasathoroughdesigninacompactformat.Simple, robustandlight(1kg).ELIRhasnoprotectiveglasswhich means10–15%higherefficiencycomparedtoaheaterwith glass with the same protection class. 2 - 2,5 m •InfraredheaterCIRisavailableintwoversions: - CIR100withoutputsbetween500and2000W. - CIR200 with the same outputs and built-in switch. •Reflectorsofhigh-glosspolishedaluminiumwithmaximum resistance against corrosion. •Greyterminalboxesofheatandweatherresistant polycarbonate. •Adjustablemountingbracketsforeasymountingonthewall or ceiling. •Max.surfacetemperature:750°C. •Colour:white,RAL9002,NCS1502-Y. •ApprovedbySEMKOandCEcompliant. Infrared heater CIR without built-in switch (IP24) Type CIR10521 CIR11021 CIR11031 CIR11521 CIR11531 CIR12021 CIR12031 Voltage [V] 230V~ 230V~ 400V2~ 230V~ 400V2~ 230V~ 400V2~ Heat output [W] 500 1000 1000 1500 1500 2000 2000 Infrared heater CIR with built-in switch (IP24) Type CIR20521 CIR21021 CIR21031 CIR21531 CIR22031 Voltage [V] 230V~ 230V~ 400V2~ 400V2~ 400V2~ Heat output [W] 500 1000 1000 1500 2000 3 LxHxD [mm] 710x44x94 1250x44x94 1250x44x94 1755x44x94 1755x44x94 2180x44x94 2180x44x94 Weight [kg] 1,5 2,2 2,2 3,0 3,0 3,7 3,7 •Allpartsareanti-corrosive. •Casing/reflectorsofhigh-glosspolishedaluminiumwith maximum resistance against corrosion. •ELIRismountedonthewallwiththeaccompanying mounting bracket or suspended from the ceiling. It can also bemountedonastandforportableuse.Suspensiondetails and stand are extra. •Greyterminalboxesofheatandweatherresistantplastic. Colour:RAL7035. •Max.surfacetemperature:2200°C. •CEcompliant. Infrared heater ELIR (IP65) Type ELIR12 Voltage [V] 230V~ 3 Heat output [W] 1200 LxHxD [mm] 712x112x83 Weight [kg] 1,0 Accessories - ELIR 3 LxHxD [cm] 710x44x94 1250x44x94 1250x44x94 1755x44x94 2180x44x94 Radi an t h e at e r s Radiant heaters - Outdoors Weight [kg] 1,5 2,2 2,2 3,0 3,7 Type Description ELIRC Chain for ceiling mounting ELIRS Floor stand (tripod) with bracket for ELIR included ELIRB Universal bracket when using any floor stand (i.e. tripod) IREL12 Extra lamp CBT Electronic timer, IP44 For controls, see pages 44 and 62-63. Accessories - CIR Type Description CIRT Stepless output control with timer, IP44 CBT Electronic timer, IP44 For controls, see pages 44 and 62-63. Min. distances ELIR [mm] Min. distances CIR [mm] 150 150 300 700 1800 Ceiling Wall / long side of the unit Wall / short side of the unit Flammable material Floor A B C D E 400 600 600 1000 1800 39 Radiant heaters - Outdoors Halogen infrared heater IH Accessories - IH Halogen infrared heater IH is the perfect choice for exposed outdoor environments where design is important, for example, 1,8 - 3,5 m balconies, pavement cafés, etc. IH can also be used as local heating in large premises such as churches, industries and warehouses. IH is easy to position thanks to its compact design. The discreet and appealing look makes it suitable for outdoor environments with design demands. •IHisavailableintwoversions: - IHWprovideswideheatdistribution(60°),recommended installationheight1.8–2.5m. - IHFprovidesdirectedheatdistribution(40°), recommendedinstallationheight2.3–3.5m. •IHconsistsofahalogenlampwithaveryhighintensityanda highly-polished reflector for optimum heat distribution. •Gives10-15%higherefficiencythanaglassfrontedheaterof the same enclosure. •Bracketforwallmounting.Canalsobesuspendedfrom theceilingormountedone.g.aparasolorapost.Other mounting alternatives are available as accessories. •Max.elementtemperature:2200°C. •Colour:grey,RAL9006. •ApprovedbySEMKOandCEcompliant. Infrared heater IHW with wide heat distribution (IPX4) Type IHW10 IHW15 Voltage [V] 230V~ 230V~ Heat output [W] 1000 1500 LxHxD [mm] 500x77x169 500x77x169 IHF10 IHF15 Voltage [V] 230V~ 230V~ Heat output [W] 1000 1500 Description CBT IHUB IHXH IHXL IHT IHTW Electronic timer, IP44 Universal bracket for IH Drooping extension bracket for high level mounting Arching extension bracket for low level mounting Triple bracket Set of three bright galvanized wires for easy hanging of IHT Post for freestanding installation Halogen lamp 1000W Halogen lamp 1500W IHP IHL1000 IHL1500 IHXH IHXL 3 Weight [kg] 1,9 1,9 Infrared heater IHF with directed heat distribution (IPX4) Type Type LxHxD [mm] 500x77x169 500x77x169 3 Weight [kg] 1,9 1,9 IHUB Min. distances IH [mm] A IHT + IHTW B C Ceiling Flammable material Floor 40 A B C 200 1000 1800 IHP + IHT Radiant heaters - Outdoors ICW ICWP ICSR ICB ICS Carbon infrared heater IC Carbon infrared heater IC produces gentle and direct heat that is ideal for indoors and conservatories as well as out on terrace. ICW gives a comfortable heat at close range and 1,8 - 3,5 m alsowiderheatdistribution.ICShasmore directed heat distribution and is designed forinstallationhigherup.ICBisespecially intended for bathrooms. The design and heating technology makes itpossibletoplaceICverticallyaswellashorizontally. The different accessories also allow a range of installation possibilities. ICW with wide heat distribution •SeveralversionsofICareavailable: - ICW provides wide heat distribution, recommended installationheight1.8-2.5m. - ICSR can be controlled by remote control or by control panel on the heater. It provides directed heat distribution, recommendedinstallationheight1.8-3.5m.Models withoutcontrolpanel/remotecontrolareavailableunder the designation ICS. - ICWPisportable(with1.5mhighstand)andproduces wide heat distribution. - ICB is intended for bathrooms. •Carbonfibrelampthatproducesgentleandfastradiantheat. Servicelife:10,000hrs •Flexiblemountingbracketforhorizontalorvertical installation,directonwallorceiling.Severalmounting options are available as accessories, such as wall and ceiling mounting on aluminium rail or with a flexible universal bracket, installation on stand or awning. •Equippedwitha1.9metrelongcordwithplugforconnection to an earthed mains socket. •Integratedoutputselectorandthermostat. •Max.elementtemperature:1200°C+/-100°C. ICB:1000°C+/-100°C. •Protectionclass,horizontalinstallation:IP44,vertical installation IP42. •Colourcasing:grey(ICW(P))silver(ICS(R)ICB). Plasticends,RAL7022(ICW(P))RAL7037(ICS(R),ICB). Chromed steel grille. •ApprovedbyTÜVandCEcompliant. ICS with directed heat distribution ICW15 ICW20 ICW30 Voltage [V] 230V~ 230V~ 230V~ Type ICSR20 ICSR30 Type ICS15* ICS20* ICS30* Voltage [V] 230V~ 230V~ Heat output [W] 2000 3000 Voltage [V] 230V~ 230V~ 230V~ Heat output [W] 1500 2000 3000 LxHxW [mm] 854x209x238 1070x209x238 Type Voltage Heat output ICWP17 [V] 230V~ [W] 1750 ICB for bathrooms 3 Weight [kg] 6,2 7,1 3 LxHxW [mm] 746x209x238 854x209x238 1070x209x238 ICWP, portable with stand, wide heat distribution LxHxW heater [mm] 837x228x231 Weight [kg] 5,0 5,2 6,3 3 Height stand [mm] 1500 Weight [kg] 10 3 Type Voltage [V] ICB8* 230V~ ICB10 230V~ ICB12* 230V~ *) Not kept in stock. Heat output [W] 800 1000 1200 LxHxW [mm] 729x228x231 729x228x231 729x228x231 Weight [kg] 4,7 4,7 4,7 Accessories - carbon infrared heater IC Type Description CBT ICPP20 ICPB ICAP15 ICAP20 ICUB ICAB ICL1500 ICL1000 ICL875 ICL750 ICL500 Electronic timer, IP44 Post, L = 2 m Stand foot Aluminium rail L = 1,5 m Aluminium rail L = 2 m Universal bracket Awning bracket Extra lamp 1500W Extra lamp 1000W Extra lamp 875W Extra lamp 750W Extra lamp 500W Min. distances ICWP [mm] Can be rotated to the vertical position. Vertical mounting IC 1-2 kW: 300 IC 3 kW: 500 Weight [kg] 5,0 5,2 6,3 100 400 (ICB: 300) 500 (ICB: 300) 2200 1800 (ICB: 400) 1800 (ICB: 400) 500 (ICB: 300) L=1500 400 LxHxW [mm] 783x228x231 891x228x231 1107x228x231 ICSR with remote control and directed heat distribution Min. distances ICW/ICSR/ICS/ICB [mm] Horizontal mounting 3 Heat output [W] 1500 2000 3000 Radi an t h e at e r s Type 400 41 Radiant heaters- water heated Comfort Panel SZR ComfortPanelSZRisusedforwatersupplied heating/coolingsystems.Itcanbemounted free hanging or integrated in false ceilings and 2,5 - 10 m perfectly suits in fine environments such as offices, shops, etc. Discreet flat satin finished surface that matchesmostfalseceilingpaneldesigns.A perfectsymmetricanbecreatedwithheating/coolingpanelsin combination with non active panels. •ComfortPanelSZRisavailableinfollowingversions: - SZRxxxP for recessed mounting in false ceilings. - SZRxxxM for free hanging mounting. •Thepanelsareavailableinfivelengthswiththreedifferent pipe settings. The lengths can be combined to a total panel lengthdesired.Nonactivepanelsareavailable. •CompliestoEN14037whichisbasedontheEUConstruction ProductDirectives89/106/CEE.EN14037iscompulsoryfora CE mark for water heated radiant heaters. •Maxworkingpressure:4bar. •Maxwatertemperature:90°C •Colour:white,RAL9016,NCS0500. •CEcompliant. Insulation 30 mm (included, not mounted) Comfort Panel SZR for recessed mounting Type*1 SZR060P SZR120P SZR180P SZR240P SZR300P SZRN60P SZRN120P Heat output*2 [W/pcs] 178 355 534 713 893 Non active Non active Weight [kg] 7 14 21 28 35 4 8 LxHxW [mm] 595x35x595 1195x35x595 1795x35x595 2395x35x595 2995x35x595 595x35x595 1195x35x595 Suspension Insulation holding strip Comfort Panel SZR for free hanging mounting Type*1 Heat output*2 Weight LxHxW [W/pcs] [kg] [mm] SZR060M 178 7 595x35x595 SZR120M 355 14 1234x35x610 SZR180M 534 21 1858x35x610 SZR240M 713 28 2482x35x610 SZR300M 893 35 3106x35x610 SZRN60M Non active 4 610x35x610 SZRN120M Non active 8 1234x35x610 *¹) The panels are available with three different pipe settings. *2) Applicable at water temperature 80/60 °C, air temperature +20 °C. Accessories - Comfort Panel SZR Type Description RTI2 Room thermostat, IP44 T10 Room thermostat, IP30 TVV20/25 2-way control valve, DN 20/25 mm SD20 Actuator TRV20/25 3-way control valve, DN 20/25 mm Suspension accessories are priced on request. A Comfort Panel handbook with detailed information is available at www.frico.se. Further information can also be obtained by contacting Frico. 42 Recessed mounting in false ceiling Radiant heaters- water heated Comfort Panel SZ 3 - 15 m Radi an t h e at e r s ComfortPanelSZistheidealsystemsolution for water supplied heating of larger buildings such as industrial buildings, commercial buildingsandsportscentres.ComfortPanelSZ is suitable for both high and low installation, and extremely high installations are possible withpressurizedhotwater. •CompliestoEN14037whichisbasedontheEUConstruction ProductDirectives89/106/CEE.EN14037iscompulsoryfora CE mark for water heated radiant heaters. •Forceilingmountinginpanellengthsof4metersupto120 meters. •Maxworkingpressure:10bar(specialversion:16bar). •Maxwatertemperature:120°C(specialversion:180°C). •Colour:white,RAL9016,NCS0500orlightgrey,RAL9002, NCS1502-Y.Othercoloursavailableonrequest. •CEcompliant. Comfort Panel SZ max 120 °C 2 Type Heat output* Weight Width [W/m] [kg/m] [mm] SZ23 162 4 300 SZ26 289 8 600 SZ29 406 12 900 SZ212 543 16 1200 SZ33 194 6 300 SZ36 345 12 600 SZ39 501 18 900 SZ312 639 24 1200 *) Applicable at water temperature 80/60 °C, air temperature +15 °C. Comfort Panel SZ special max 180 °C 2 Type Heat output* Weight Width [W/m] [kg/m] [mm] SZ23SP 267 5 300 SZ26SP 477 10 600 SZ29SP 667 15 900 SZ212SP 870 20 1200 SZ33SP 324 7 300 SZ36SP 574 14 600 SZ39SP 790 21 900 SZ312SP 1005 28 1200 *) Applicable at water temperature 130/70 °C, air temperature +15 °C. Accessories - Comfort Panel SZ Type Description RTI2 T10 TVV20/25 SD20 TRV20/25 Room thermostat, IP44 Room thermostat, IP30 2-way control valve, DN 20/25 mm Actuator 3-way control valve, DN 20/25 mm 1. Threaded male connection (Ø 1/2” - 3/4” - 1” - 1.1/4”) 2. Connection for drain valve Ø 3/8” 3. Connection for air vent. valve Ø 3/8” 4. First or end header 5. Steel pipe Ø 1/2” 6. Radiant panel 7. Suspension bracket 8. Insulation 9. Side edging strip 10. Insulation retaining clip 11. Anti-convective side skirts (accessory) 12. Skirt hook 13. Pipe ends adapted for press fitting or compression fitting or belled end for welding 14. Make-up joint 15. Make-up joint between panel and header (accessory) A Comfort Panel handbook with detailed information is available at www.frico.se. Further information can also be obtained by contacting Frico. 43 Radiant heaters - Controls ERP, electric heating control CIRT, stepless output control with timer Steplesspulsecontrolintendedforsinglephase(3600W/230V) ortwophase(6000W/400V2~)electricheaters.Cannotcontrol 3phaseloads.Pulsetime60secs.Triaccontrol(quietcontrol). Integrated temperature sensor. External sensors available as anaccessory.Savereductionfunctionviaexternalconnection timer(1–10degrees).Forlargerpoweroutputsaslaveunit (ERPS)canbeconnected.EachERPScanhandlethesame powerasERP. Steplessoutputcontrolwithtimer,primarilyintendedfor infrared heaters and other radiant heaters. Intended for single phase(3600W/230V~)ortwophase(6000W/400V2~)electric heaters.Especiallysuitedforspotamdzoneheating.Theheat contributionisregulatedforbestcomfort(25-100%).The built-intimercanbesetfor0.5to4or4to24hours.High protection class (IP44). Electric heating control ERP (IP20) Output control CIRT (IP44) Type ERP ERPS Voltage [V] 230/400V~ 230/400V~ HxWxD [mm] 153x93x40 153x93x40 Type CIRT Voltage [V] 230/400V2~ HxWxD [mm] 155x87x43 Accessories ERP Type Description ERPRG ERPGG Room sensor ERP Floor/duct sensor ERP S123, manual switch for 1-2-3 steps Controlstheoutputinthreesteps0-1/3-2/3-3/3. Manual switch S123 (IP44) Type S123 44 Voltage [V] 230/400V3~ HxWxD [mm] 72x64x46 Fan heaters For decades Frico has been the world leader in fan heater design. Today we have a complete range of high quality equipment modelled on the demanding climate of Scandinavia. Frico’s worldwide distribution network encounters many different environmental conditions, such as storage rooms, pump rooms, building sites, mines, sports centres, shops, drying rooms, stables, boats, etc. We are proud of the worldwide acclaim we have gained through our line of fan heaters. They are known as reliable and long-lasting products. The heaters are also robust and will withstand rough treatment in aggressive environments, at the same time having the lowest sound level on the market. Exceptionally quiet One of the most important tasks in our product development, is the construction of low noise fan heaters. At our plant in Skinnskatteberg, Sweden, you will find one of the most sophisticated air and sound laboratories in Europe, staffed by highly skilled technicians making it possible to manufacture products of the finest quality. Lots of power, small investment Fan heaters Compared to other heating systems, the investment cost for fan heaters is low. Frico fan heaters give you lots of power for the money. Compact and robust Frico fan heaters are compact and light. Therefore they are easy to carry or can easily be mounted on the wall. The heaters are also very robust and withstand heavy handling in aggressive environments. Electricity or water? Frico fan heaters are available for electrical or water heating you have the choice! Heating and ventilation A great advantage of fan heaters is the option of combining heating and ventilation. Mixing cabinets for stationary fan heaters create economic heating and ventilation, by mixing the return air with fresh air. 45 Fan heaters - electrically heated Door heater PA1006 Fan heater K21 PA1006isacompactdoorheaterwhichheatstheincomingair andgivesincreasedcomfortontheinside.Whenwallmounted, theunitcanactasastationaryfanheater. Thedoorheaterhasaclean,straightforwarddesign.Asthe air inlet is placed on top of the unit the front of the unit is kept free of dirt and dust. K21 is a compact and safe fan heater designed for portable use. Ideal for heating small areas, for example, garages, caravans, awnings, weekend cottages, offices, patios, etc. K21 fan heater is small and compact in white metal finish and is equipped with a solid handle. •Compactandeasytoposition. •Lowsoundlevel. •Theunitiseasilyangledonthebracket,whichisusedfor both wall and ceiling mounting. •Integratedcontrol. •Designedforpermanentinstallationandisconnectedvia cable without plug. •Colour:white,RAL9016,NCS0500. •CEcompliant. •Self-regulatingceramicPTCelementthatcannotbe overheated. •Intensiveandconcentratedheatemission.Theairisheated toapprox.65°CwhenitpassesthroughK21. •Equippedwith2metrelongcordwithplugforconnectionto an earthed outlet socket. •Thermostat(+5–+35°C)andoutputselector(0/1/2kW). •DimensionsHxBxD:220x160x200mm. •Colour:white,RAL9016,NCS0500. •ApprovedbySEMKOandCEcompliant. Door heater PA1006E03 (IP20) Fan heater K21 (IP21) Type 3 Voltage Output Airflow Sound HxWxD Weight steps level* [V] [kW] [m³/h] [dB(A)] [mm] [kg] PA1006E03 230V~ 0/1.5/3 230 44 153x164x650 5,3 *) Conditions for sound level measurements, see page 67. 46 Type 3 Voltage Output Airflow Sound [V] steps level* [kW] [m³/h] [dB(A] K21 230V~ 0/1/2 90 43 *) Conditions: Distance to unit 5 metres. HxWxD Weight [mm] 220x160x200 [kg] 2,5 Fan heaters - electrically heated Fan heater Tiger •TheTigerfanheaterisavailableinthefollowingdesigns: -P21 and P31 have a 1.8 m cord with plug for connection to earthedoutletsockets.Canbehungonthewall. -P33, P53 and P93havea1.8mcablewithCEE-plug. 230V-outletsocket(typeE)attherear.Canbehungonthe wall. -P153hasa1.8mcablewithCEE-plug.Canbehungonthe wall. -P203, P303 and P305 are supplied with a 1.8 m cable withoutaplug.P305canbeconnectedto440V3~and 500V3~. •Lowsoundlevel. •Integratedthermostatwithsettingrange+5–+35°Cand output selector. •Colour:red,RAL3020,NCS1090-Y80R. •CEcompliant. Conditions for sound level measurements, see page 67. Fan heater Tiger 2–9 kW (IP44) Type 3 Voltage Output Airflow Sound HxWxD Weight steps level [V] [kW] [m³/h] [dB(A)] [mm] [kg] P21 230V~ 0/2 280 41 450x290x390 5,7 P31 230V~ 0/2/3 280 41 450x290x390 6,0 P51 230V~ 0/3,3/5 480 41 450x290x390 6,4 P33 400V3N~* 0/1,5/3 280 41 450x290x390 6,3 P53 400V3N~* 0/2,5/5 480 40 450x290x390 6,7 P93 400V3N~* 0/4,5/9 720 44 530x350x480 10 *) Also available without neutral and are then called P33-0, P53-0 and P93-0. These models do not have a 230 V~ socket on the back. Fan heater Tiger 15 kW (IP44) Type Voltage P153 [V] 400V3~ Output steps [kW] 0/7,5/15 3 Airflow Sound level [m³/h] [dB(A)] 1120 47 Fan heater Tiger 20 and 30 kW (IP44) Type HxWxD Weight [mm] 510x410x530 [kg] 16 3 Voltage Output Airflow Sound HxWxD steps level [V] [kW] [m³/h] [dB(A)] [mm] P203 400V3~ 0/10/20 1900/2600 60 590x630x600 P303 400V3~ 0/10/20/30 1900/2600 52 590x630x600 P3053* 440V3~ 0/7,5/15/23 1900/2600 52 590x630x600 500V3~ 0/10/20/30 *) Can be connected to 440V3~ and 500V3~. Fan heaters Tigerisarangeofrobustandcompactfanheatersfor professionalswithhighdemands.TheTigerfanheateris portable,modelsupto15kWcanalsobehungonthewall. Tiger2-9kWareintendedforheatinganddryingareassuch as garages, workshops and shops. Tiger15,20and30kWareidealforheatinganddrying larger premises such as industrial premises and workshops, where higher outputs are required. TheTigerfanheaterhasacompactandrobustsheetsteel designwitharedfinish.Theheavy-dutytubularframeactsas awell-balancedandergonomiccarryinghandle.Thedesign protects against impact and vibrations and permits use in exacting environments. Weight [kg] 26 30 30 Accessories - Tiger Type Description LT22406 Wall bracket 47 Fan heaters - electrically heated Fan heater Cat Catisarangeofcompactandquietfanheatersforstationary use.Itisideallysuitedforsmallstockrooms,inagarage, workshoporshop.Themixingcabinet(accessory)allows heating and ventilation to be combined, through mixing the return air and outdoor air. TheCatfanheaterhasaclassiccleandesigninwhite enamelled sheet steel. It is small and unobtrusive and with thateasytoposition. CMB35 with Cat •Lowsoundlevel. •Wallbracketwith10°tiltangleforgoodheatdistribution. •Integratedthermostatwithsettingrange+5–+35°Cand outputselector.Externalcontrol,forexample,thermostat and timer is possible. •Colour:white,RAL9016,NCS0500. •CEcompliant. Fan heater Cat (IP44) Type Voltage 3 Output steps [kW] 0/1,5/3 Airflow Sound HxWxD level [m³/h] [dB(A)] [mm] 280 41 255x335x276 Weight [V] [kg) 230V~ 6,3 400V3N~ C5 400V3N~ 0/2,5/5 480 40 255x335x276 6,7 C9 400V3N~ 0/4,5/9 720 44 315x405x335 10,2 *) C3 can be connected for 230V~ and 400V3N~. Other models should not be connected for single phase, 230V~. C3* EV300 EV300, output selector Outputselectorwithoutputsteps0-1/2-1/1.IP44. CMB35, mixing cabinet MixingcabinetforC3andC5.Saveenergybymixingthe outdoorairwiththereturnairinindividuallyselected proportions.Anouterwallgrille,awalling-inframeandahand controller are supplied with the mixing cabinet. TP3/5 and TP9, cover panel for switches Coverstheswitchesontheheaterandpreventschangesinthe settings. Accessories - Cat Control kits Cat Built-in control: Thebuilt-inthermostatcontrolsfanspeedandheat,or heatonly.Thechoiceismadewiththemodeselector. Theoutputcanbecontrolledviathebuilt-inoutput selector(0-1/2-1/1). External regulation: - T10/TK10roomthermostats - EV300,outputselector - CBT,electronictimer 48 Type Description T10 Room thermostat, IP30 TK10 Room thermostat with knob, IP30 TKS16 Room thermostat with knob, 1-pole switch, IP30 KRT1900 Room thermostat, IP55 EV300 Output selector, IP44 CBT Electronic timer, IP44 KUR Digital time switch, IP55 CMB35 Mixing cabinet for C3 and C5 TP3/5 Cover panel for switches for C3 and C5 TP9 Cover panel for switches for C9 For controls, see pages 62-63. Conditions for sound level measurements, see page 67. Fan heaters - electrically heated Elektra - C/F/V/H •TheElektrafanheaterisavailableinfourdesigns: -Elektra C is intended for corrosive and damp environments,forexample,car-washhallsandsewage works.Outercasingofacid-proofsheetsteel.IP65. -Elektra F has a low element temperature and is approved foruseincombustibleareas,forexample,joinery workshopsandagriculturalbuildings.IP65. -Elektra V is designed to withstand vibrations on ships and offshoreplatformsandisapprovedbyDetNorskeVeritas. Alsoavailablefor440V/60Hz.IP44. -Elektra H is designed for rooms with high temperatures, up to70°C.IP44. •Colour:stainlesssteeloutercasing(ElektraChasanacidproofoutercasing).Grilleandbracket:red,RAL3020. •ApprovedbySEMKOandCEcompliant.ElektraVis approvedbyDetNorskeVeritas. Fan heater Elektra C for corrosive and humide environments (IP65) Type Voltage ELC331 ELC633 ELC933 ELC1533 Airflow HxWxD Weight [V] 230V~ [m³/h] 400 [mm] 375x300x340 [kg] 13 400V3~ 400V3~ 400V3~ 0/3/6 0/4,5/9 0/7,5/15 1000 1000 1300 445x375x430 445x375x430 445x375x430 20 20 20 Type Vvoltage ELF331 ELF633 ELF933 [V] 230V~ 400V3~ 400V3~ Output steps [kW] 0/1,5/3 0/3/6 0/4,5/9 3 Airflow HxWxD Weight [m³/h] 400 700 1000 [kg] 13 13 20 [mm] 375x300x340 375x300x340 445x375x430 Fan heater Elektra V for ships and offshore platforms (IP44) Type Voltage ELV331 ELV3333 ELV3344 ELV5333 ELV6344 [V] 230V~ 400V3~ 400/440V3~ 400V3~ 400/440V3~ Output steps [kW] 0/2/3 0/1,5/3 0/1,8/3,6 0/2,5/5 0/3/6 Weight [m³/h] 400 400 400 700 700 [kg] 13 13 13 13 13 Fan heater Elektra H for high temperatures (IP44) Type Voltage ELH633 ELH933 [V] 400V3N~ 400V3N~ Output steps [kW] 0/3/6 0/4,5/9 3 Airflow HxWxD [mm] 375x300x340 375x300x340 375x300x340 375x300x340 375x300x340 Elektra C / Elektra V -ELSRT,controlbox,controlsoneunit -ELSRT4,controlbox,controlsfourunits Elektra F -ELS,controlbox,controlsoneunit Elektra H -ELRT,roomthermostat ELSRT ELSRT4 ELS ELRT ELSRT/ELSRT4, control panel Therequiredoutputandtemperaturecanbesetonthecontrol panel.Integratedthermostat,+5–+35°C.Usedforexternal control, for example, when installed high on a wall. ELSRT controlsonlyoneunit.ELSRT4 can control up to four units. IP65. ELS, control panel start/stop Controlpanelthatstarts/stopsthefan,forexternalcontrol,for example,wheninstalledhighonawall.Onlyoneunitcanbe controlledfromonecontrolpanel.IP65. ELRT, room thermostat Capillarytubethermostatwithvisibledial.Settingrange 0-+70°C.Max.breakingcurrent:16A.IP44. Accessories - Elektra Type Description Control box with thermostat for ELC and ELV, start/stop, 175x150x100 mm, IP65 ELSRT4 Control box with thermostat for ELC and ELV, start/stop, for 4 units, 255x360x110 mm, IP65 ELS Control box for ELF, start/stop, 105x70x80 mm, IP65 ELRT Room thermostat for ELH, 175x150x100 mm, IP44 KRT1900 Room thermostat, IP55 For controls, see pages 62-63. ELSRT 3 Airflow HxWxD Weight [m³/h] 1000 1000 [kg] 20 20 [mm] 445x375x430 445x375x430 FanheaterElektraHfeaturesanintegratedthermostat withtheworkingrange0–+70°C,othermodelsfeaturean integratedthermostatwiththeworkingrange0–+35°C.The output can be selected using the output selector on the unit or on the external control panel. 3 Output steps [kW] 0/1,5/3 Fan heater Elektra F for combustible areas (IP65) Control options Fan heaters Elektraisarangeoffanheatersdesignedforuseindemanding environments.Thedifferentmodelscanbeusedanywhere from corrosive environments and combustible areas to rooms with high temperatures as well as onboard ships and offshore platforms.Elektraismainlydesignedforstationaryuse,yet can also be used as a portable fan heater. TheElektrafanheaterhasamoderndesignwithastainless steeloutercasing,redgrilleandredbrackets.Thebrackets canberotated,whichmeansElektracanalsobeusedasa portable fan heater. 49 Fan heaters - electrically heated Fan heater Panther 6-15 Fan heater Panther 20-30 Panther6-15isarangeofveryquietandefficientfanheaters forstationaryuse.Theyareintendedforheating,dryingand ventilationine.g.workshops,sporthalls,shops,assembly roomsanddryingrooms.Themixingcabinet(accessory) allows heating and ventilation to be combined, through mixing the return air and outdoor air. ThePantherfanheaterhasaclassiccleandesigninwhite enamelled sheet steel. Panther20–30isarangeofpowerfulandquietfanheaters forstationaryuse.Theyareintendedforheating,dryingand ventilationoflargepremises,forexample,industries.The mixingcabinet(accessory)allowsheatingandventilationtobe combined, through mixing the return air and outdoor air. ThePantherfanheaterhasaclassiccleandesigninwhite enamelled sheet steel. •Lowsoundlevel. •Suppliedwithwallbracketthatmakesitpossibletodirect the airflow down and to the side. •Timedelaybetweentheoutputsteps. •Integratedthermostatwithsettingrange+5–+35°C, possibilitytoconnectanexternalthermostat. •ExternalcontrolpanelPP15(orderedseparately)with master/slavefunction,foruptosixunitsgivesgoodand simple control. •Colour:white,RAL9016,NCS0500. •CEcompliant. Fan heater Panther 6-15 kW (IP44) Type Voltage Fan heater Panther 20 and 30 kW (IP44) 3 Output Airflow Sound steps level [V] [kW] [m³/h] [db(A)] SE06 400V3N~ 0/3/6 900/1300 39/47 SE09 400V3N~ 0/4,5/9 900/1300 39/47 SE12 400V3N~ 0/6/12 900/1300 39/47 SE15 400V3N~ 0/7,5/15 900/1300 39/47 SE135 440V3~ 0/5/10 900/1300 39/47 500V3~* 0/7/13,5 900/1300 *) Can be connected to 440V3~ and 500V3~. HxWxD Weight [mm] 520x450x510 520x450x510 520x450x510 520x450x510 520x450x510 520x450x510 [kg] 21 22 22 22 23 Control kits Panther 6-15 kW Fan speed and thermostat control: - RTI2orKRT2800,2-steproomthermostats - PP15,controlbox,controlstheoutputintwostepsand the airflow in three steps. Automatic temperature control: - PTA,automatictemperaturecontrol Control of mixing cabinet: - PHR01,controllever,manualdampercontrolor - PSA01,automaticdamperandtemperaturecontrol - PSM01,dampermotor,isusedincombination withPSA01whenseveralmixingcabinetsshouldbe controlled 50 •Suppliedwithwallbracketthatmakesitpossibletodirect the airflow down and to the side. •Timedelaybetweentheoutputsteps. •Post-runningthermostatforefficientcooling. •ExternalcontrolpanelPP20/30(orderedseparately)with master/slavefunction,foruptosixunits,andexternal thermostat,forexample,RTI2givesgoodandsimplecontrol. •Colour:white,RAL9016,NCS0500. •CEcompliant. Conditions for sound level measurements, see page 67. Type 3 Voltage Output Airflow Sound steps level [V] [kW] [m³/h] [db(A)] SE20 400V3N~ 0/10/20 1900/2600 52/60 SE30 400V3N~ 0/10/20/30 1900/2600 52/60 SE305 440V3~ 0/7,5/15/23 1900/2600 52/60 500V3~* 0/10/20/30 1900/2600 *) Can be connected to 440V3~ and 500V3~. HxWxD Weight [mm] 576x478x545 576x478x545 576x478x545 576x478x545 [kg] 27 31 32 Control kits Panther 20 -30 kW Fan speed and thermostat control: - RTI2orKRT2800,2-steproomthermostats - PP20,controlbox,controlstheoutputintwostepsand theairflowintwosteps(SE20) - PP30,controlbox,controlstheoutputinthreesteps andtheairflowinthreesteps(SE30,SE305). Automatic temperature control: - PTA,automatictemperaturecontrol Control of mixing cabinet: - PHR01,controllever,manualdampercontrolor - PSA01,automaticdamperandtemperaturecontrol - PSM01,dampermotor,isusedincombination withPSA01whenseveralmixingcabinetsshouldbe controlled Fan heaters - electrically heated PTRP 4h 2h 1h 12 CBT CBT TTF140 PP15/20/30 PTA01 PSA01 KRT1900 PBS01/02 PP15/20/30, control box Thedesiredoutputandfanspeedcanbesetonthecontrol box.Upto6unitscanbecontrolledbyonecontrolbox. Protectionclass:IP44. PTA01, automatic temperature control PHR01, control lever for mixing cabinet Usedwiththemixingcabinet,ifyouwishtocontrolthe dampermanually.Thepull-rod(notincluded)forthelever should have a diameter of 8 mm. PSA01, automatic damper and temperature regulator Usedonthemixingcabinet.Lowersthetemperatureand reduces the amount of outdoor air during periods with a low requirement.Consistsoftimer(weeklytimer),thermostat with external sensor, potentiometer and damper motor. Exhaustairfanscanpossiblybecontrolledfromtheautomatic system.Onedampermotor(PSM01)included.IP55. PSM01, damper motor UsedincombinationwithPSA01whenseveralmixingcabinets shouldbecontrolled.(1dampermotorisincludedinPSA01.) Protectionclass:IP54. Accessories Panther 6-12, 20 and 30 kW Type Description PP15 Control box SE06 - SE15, IP44 PP20 Control box SE20, IP44 PP30 Control box SE30 and SE305, IP44 PTA01 Automatic temperature control, IP55 PBS01 Mixing cabinet SE06 – SE15 PBS02 Mixing cabinet SE20, SE30 and SE305 PHR01 Control lever for mixing cabinet PSM01 Damper motor, IP54 PLR15 Air director SE06 – SE15 PLR30 Air director SE20, SE30 and SE305 PSA01 Automatic damper and temp. control, IP55 PTRP Drying room kit without fan heater PFF15 Exhaust air fan SE06 – SE15, IP54 PFF30 Exhaust air fan SE20, SE30 and SE305, IP54 KRT2800 2-step room thermostat, IP55 RTI2 2-step room thermostat, IP44 RTI2V 2-step room thermostat with knob, IP44 CBT Electronic timer, IP44 KUR Digital time switch, IP55 For controls, see pages 62-63. Fan heaters PTA01canbeusedtolowertheheatwhennecessary (1–10°C),forexampleatnightorweekends.Thecontrol consists of an electronic timer and thermostat with an external sensor.Thetimeralternatesbetweendayandnightmode. Protectionclass:IP55. PBS01/02, mixing cabinet Savesenergybymixingreturnairwithfreshairinpreset proportions.Themixingcabinetisdeliveredwithawallframe and outer wall grille. PLR15/30, air director Theairdirectordirectstheairflowverticallyorlaterally.PLR issnappedonthefrontoftheheater.Torsional(turning)angle 0–35°. PFF15, exhaust air fan Canbeusedwithfanheater/mixingcabinettoobtaingood ventilation.Airflowapprox.1400m³/h.Protectionclass:IP54. PFF30, exhaust air fan Canbeusedwithfanheater/mixingcabinettoobtaingood ventilation.Airflowapprox.2600m³/h.Protectionclass:IP54. PTRP, drying room kit ConsistsofexhaustairfanTTF140withflexihoseand connectionsleeve,thermostatKRT1900andtimerCBT.The exhaustairfanworksalternatelywith,forexample,afan heater,whichgivestheshortestpossibledryingtimeand minimalenergyconsumption.Supplementedwithafanheater fromthePantherrangewithoutput6-12kW. 51 Fan heaters - water heated Fan heater SWH SWHbelongstoanewgenerationofintelligentfanheaters withSIReintegratedcontrols.SWHandSIRetogethercan providefullyautomaticroomheating,adaptabletoeacharea of use. SWHissuitableforuseinpremiseswherefanheatersare traditionallyused,suchasindustrialbuildings,aswellas environments with low sound requirements. •IntegratedcontrolsystemSIRe. •Verylowsoundlevel. •Fivefanspeeds. •Mountedonthewallorceiling. •Intendedforwatertemperaturesupto+125°Cand10barin standard design. •Colour:RAL9016,NCS0500(white).Aluminiumlouvres. •CEcompliant. Fan heater SWH (IPX4) Type Output* Airflow Sound HxWxD Weight level [kW] [m³/h] [dB(A)] [mm] [kg] SWH02 12 1120 39 525x515x320 15 SWH12 20 1810 48 600x535x340 19 SWH22 33 3260 55 725x680x370 27 SWH32 51 5860 58 850x820x450 46 SWH33 66 5420 58 850x820x450 46 *) Applicable at water temperature 80/60 °C, air temperature, in +15 °C Control options SWHissuppliedwithanintelligentandwelldesignedlow voltagecontrolsystemSIRewhichcanbecustomisedforeach uniqueapplicationandenvironment.Thecontrolsystemis pre-installedinSWHwithanintegratedPCboard.Ifmorethan oneSWHshouldbecontrolledbyasingleSIRe,anadditional modularcableSIReCCperunitisneeded.Cablesbetween unitscaneasilybejoinedtogetherbyusingjointpiece SIReCJ.SIReissuppliedpre-programmedwithquickfitplug connectionsandisveryeasytouseandinstall. SIRelearnstherequirementsandcanprovidefully automated room heating with calendar function and selectable switchoffatsettemperaturesforuptonineunits.UsingSIRe nomoreenergyisconsumedthannecessary.Becausethefan speed is adapted , the sound level is optimised and is never higherthanisnecessaryforcomfort.WithSIReAdvanced itispossibletochoosebetweenEcoandComfortmode dependentonwhetherenergysavingsoroptimalcomforthas beenprioritised.SIReAdvancedcanalsobeusedforsimple and safe ventilation solutions using mixing cabinets, control isfullyautomaticandalsohasbuilt-infrostprotection.There arethreedifferentlevelswithdifferentfunctionalitytochoose from,Basic,CompetentorAdvanced.TheSIRecontrolsystem can be supplemented with a valve kit for a complete solution. Functions SIReB Basic •Manualregulationofthefanandtemperature •Automaticcontroloffanspeedandtemperaturewith integrated thermostat. Functions SIReFC Competent •AllfunctionsforBasic •Calendarfunction •Filteralarm •SimpleBMScontrol-on/off,fanspeedandalarmfunctions Functions SIReFA Advanced •AllfunctionsforCompetent •Ecomode-extraenergy-efficientmode •Comfortmode-whencomfortisimportant •AdvancedBMScontrol •Maxlimitofreturnwatertemperature. •Steplessheatcontrol. •Possibilitytouseanexternalfilterguard. •Model(SIReFAWM)Forfullyautomaticcontrolofventilation andheatingwithmixingcabinet.OneSIReFAWMperunitis needed. Integrated frost protection. Control - Fan heater SWH 52 Conditions for sound level measurements, see page 67. Type Description SIReB SIReFC SIReFA SIReFAWM Control system SIRe Basic Control system SIRe Competent for fan heaters Control system SIRe Advanced for fan heaters Control systemSIRe Advanced for fan heaters with mixing cabinet Fan heaters - water heated SIReRTX SIReUR SIReWTA SIRe Competent /Advanced Included in SIReB Basic: •SIReB1,integratedPCboardBase •SIReIT,internaltemperaturesensor •SIReUB1,controlunit.Wallunitcoverincluded. •SIReCC,modularcable,RJ12(6/6),5m Options: •SIReRTX,externalroomtemperaturesensor •VOS(P),(pressureindependent)valvekiton/offorVOT,three wayvalveandactuatoron/off Included in SIReFC Competent: •SIReB1,integratedPCboardBase •SIReIT,internaltemperaturesensor •SIReUA1,controlunit.Wallunitcoverincluded. •SIReC1X,PCboardHUBCompetent •SIReCC,modularcables,RJ12(6/6),3mresp.5m Options: •SIReRTX,externalroomtemperaturesensor •SIReUR,kitforrecessedinstallation •VOS(P),(pressureindependent)valvekiton/offorVOT,three wayvalveandactuatoron/off Included in SIReFA Advanced: •SIReB1,integratedPCboardBase •SIReIT,internaltemperaturesensor •SIReUA1,controlunit.Wallunitcoverincluded. •SIReA1X,PCboardHUBAdvanced •SIReOTX,outdoortemperaturesensor •SIReCC,modularcables,RJ12(6/6),3mresp.5m Options: •SIReRTX,externalroomtemperaturesensor •SIReUR,kitforrecessedinstallation •SIReWTA,clamp-onsensor •VMO(P),(pressureindependent)modulatingvalvekitor VMT,threewayvalveandmodulatingactuator Included in SIReFAWM Advanced with mixing cabinet: •SIReB1,integratedPCboardBase •SIReIT,internaltemperaturesensor •SIReUA1,controlunit.Wallunitcoverincluded. •SIReA1X,PCboardHUBAdvanced •SIReOTX,outdoortemperaturesensor •SIReWTA,clamp-onsensor •SMM24,dampermotor •SIReCC,modularcables,RJ12(6/6),3mresp.5m Options: •SIReRTX,externalroomtemperaturesensor •SIReUR,kitforrecessedinstallation •VMO(P),(pressureindependent)modulatingvalvekitor VMT,threewayvalveandmodulatingactuator Accessories - SIRe Type Description SIReRTX SIReUR SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 SIReCC610 SIReCC615 SIReCC403 SIReCC405 SIReCC410 SIReCC415 External room temperature sensor Kit for recessed installation Clamp-on sensor Joint piece for two pcs RJ11 (4/4) Joint piece for two pcs RJ12 (6/6) Modular cable RJ12 3 m Modular cable RJ12 5 m Modular cable RJ12 10 m Modular cable RJ12 15 m Modular cable RJ11 3 m Modular cable RJ11 5 m Modular cable RJ11 10 m Modular cable RJ11 15 m Fan heaters SIRe Basic Water control ValvekitVOS(P),VOT,VMO(P)orVMTisusedtocontrolthe water flow, see final section of this catalogue. Water control - SWH Type Description Valve kit on/off, low flow, DN15, Kvs 0,90 Valve kit on/off, DN15, Kvs 1,8 Valve kit on/off, DN20, Kvs 3,4 Valve kit on/off, DN25, Kvs 7,2 Pressure independent valve kit on/off, low flow, DN15 Pressure independent valve kit on/off, DN15 Pressure independent valve kit on/off, DN20 Pressure independent valve kit on/off, DN25 3-way control valve and actuator on/off, DN15, Kvs 1,7 3-way control valve and actuator on/off, DN20, Kvs 2,5 3-way control valve and actuator on/off, DN25, Kvs 4,5 Modulating valve kit, low flow, DN15, Kvs 0,40 Modulating valve kit, DN15, Kvs 1,0 Modulating valve kit, DN20, Kvs 2,0 Modulating valve kit, DN25, Kvs 4,0 Pressure independent and modulating valve kit, low flow, DN15 VMOP15NF Pressure independent and modulating valve kit, DN15 VMOP20 Pressure independent and modulating valve kit, DN20 VMOP25 Pressure independent andmodulating valve kit, DN25 VMT15 3-way control valve and modulating actuator, DN15, Kvs 1,7 VMT20 3-way control valve and modulating actuator, DN20, Kvs 2,5 VMT25 3-way control valve and modulating actuator,DN25, Kvs 4,5 VAT Adjustement tool for valve kits VOS15LF VOS15NF VOS20 VOS25 VOSP15LF VOSP15NF VOSP20 VOSP25 VOT15 VOT20 VOT25 VMO15LF VMO15NF VMO20 VMO25 VMOP15LF 53 Fan heaters - water heated 2 3 SWB, mounting brackets Whennotusingthefiltersectionormixingcabinetthemain unitissuspendedfromthewallorceilingusingbracketsSWB (fig2).Bracketsareextraandsuppliedasapair. 6 4 SWFTN, basic filter Usedasanalternativetothefiltersection.Providestheheating coilwithbasicprotection.ThefilteriseasilyfittedintotheSW unitandcanbecleanedfromeitherthetoporbottom.The SWHunithasare-usablefilter(fig3). SWF, filter section Fig.4.Filterstheoutdoorairor/andreturnairfromparticles thatmightreducetheperformanceandreliabilityofSWH. Thedisposabledeep-pleatedbagfilterisacassetteofsynthetic material.FilterclassG85(EU3).Thefiltersectionisequipped withfilterondelivery. Note!Ifthefiltersectionisnotusedincombinationwiththe mixingcabinet,areturnairintake(SWD)isrequired. SWEF, extra filtercassette ReplacementfilterforSWF. SWD, return air intake Fig.5.Allowsairintakewhenfiltersectionisusedwithout mixingcabinetSWBS.Returnairintakeisnotrequiredwhen the mixing cabinet is used. SWBS, mixing cabinet Fig.6.Themixingcabinetisusedtocombineventilationwith heatingbymixingoutdoorairwithreturnair.Themixture ratioiscontrolledandinfinitelyvariablewithadamper,either manuallyorwithadampermotor. SWY, outer wall grille Fig.7.Forintakeoffreshairintothemixingcabinet.Grilleof hotzinc-platedsteelpanels. SWLR, extra air director Fig.8.Todirecttheairstreamsideways.Ondelivery,SWHis equipped with an air director for vertical direction of the air stream.Individuallyadjustablelouvresinanodisedaluminium. TheextraairdirectorismountedtoSWHbyhookingitonto the existing air director. 54 1 8 5 1) Fan heater SWH 2) Mounting brackets SWB 3) Basic filter SWFTN 4) Filter section SWF 5) Return air intake SWD 6) Mixing cabinet SWBS 7) Outer wall grille SWY 8) Extra air director SWLR Accessories - Fan heater SWH and SWS Type Description SWB0 SWB1 SWB2 SWB3 SWFTN02 SWFTN1 SWFTN2 SWFTN3 SWF1 SWF2 SWF3 SWEF1 SWEF2 SWEF3 SWD1 SWD2 SWD3 SWBS1 SWBS2 SWBS3 SWY1 SWY2 SWY3 SWLR1 SWLR2 SWLR3 Mounting brackets SWH/SWS02 Mounting brackets SWH/SWS12 Mounting brackets SWH/SWS22 Mounting brackets SWH/SWS32/33 Basic filter SWH/SWS12 Basic filter SWH/SWS12 Basic filter SWH/SWS22 Basic filter SWH/SWS32/33 Filter section SWH/SWS12 Filter section SWH/SWS22 Filter section SWH/SWS32/33 Extra filter cassette SWH/SWS12 Extra filter cassette SWH/SWS22 Extra filter cassette SWH/SWS32/33 Return air inlet (SWF1) SWH/SWS12 Return air inlet (SWF2) SWH/SWS22 Return air inlet (SWF3) SWH/SWS32/33 Mixing cabinet SWH/SWS12 Mixing cabinet SWH/SWS22 Mixing cabinet SWH/SWS32/33 Outer wall grille SWH/SWS12 Outer wall grille SWH/SWS22 Outer wall grille SWH/SWS32/33 Extra air director SWH/SWS12 Extra air director SWH/SWS22 Extra air director SWH/SWS32/33 7 Fan heaters - water heated Fan heater SWS 3 2 FanheaterSWSisintendedforwater-heatingorcooling.SWS issuitableforplaceswherefanheatersaretraditionallyused, such as industrial premises, workshops and storage rooms. Thefanheatercanbemountedonthewallortheceiling.By turning the unit the water connections will be positioned on the left or right side. FanheaterSWShasacompactandfunctionaldesignwell suitable for the applications it is intended for. 7 6 4 Fan heater SWS (IPX4) 2 Type Voltage Output* Airflow Sound HxBxD Weight level [V] [kW] [m³/h] [dB(A)] [mm] [kg] SWS02 230V~ 12 1260 50 470x520x260 14 SWS12 230V~ 19 2340 57 545x540x275 18 SWS22 230V~ 30 3560 58 675x690x275 26 SWS32 230V~ 50 6300 64 800x830x350 45 SWS33 230V~ 65 6090 64 800x830x350 45 SWS323 400V3~ 48 5890 62 800x830x350 45 SWS333 400V3~ 62 5660 62 800x830x350 45 *) Applicable at water temperature 80/60 °C, surrounding temperature +15 °C, fan position: max. Control options 230V~ Control by thermostat only -KRT1900orT10/TK10,roomthermostat -TVV20/25,valve+SD20,actuator 5-step control of airflow only -RE1,5,5-stepregulatormax1,5A,or RE3,5-stepregulatormax3A,or RE7,5-stepregulatormax7A Thermostat and 5-step control -RE1,5,5-stepregulatormax1,5A,or RE3,5-stepregulatormax3A,or RE7,5-stepregulatormax7A -KRT1900orT10/TK10,roomthermostat -TVV20/25,valve+SD20,actuator Control options 400V~ 2-step control of airflow only -SWYD1,2-stepchange-overswitchforairflow(Y/D) -STDT16,thermalcontactmotorprotection Termostatstyrning av värmen och 2-stegsreglering av luftflödet -SWYD1,2-stepchange-overswitchforairflow(Y/D) -STDT16,thermalcontactmotorprotection -KRT1900orT10/TK10,roomthermostat -TVV20/25,valve+SD20,actuator Conditions for sound level measurements, see page 67. 5 1 8 1) Fan heater SWS 2) Mounting brackets SWB 3) Basic filter SWFTN 4) Filter section SWF 9 5) Return air intake SWD 6) Mixing cabinet SWBS 7) Outer wall grille SWY 8) Extra air director SWLR 9) Drip tray SWST RE1,5/RE3/RE7, 5-step change-over switch for air flow Controlstheairflowin5steps.RE1,5 controls maximum 1,5 A.RE3controlsmaximum3A.RE7controlsmaximum7A.To controltheheat,asuitablethermostatandavalve+actuator areneeded.IP54. Fan heaters •Mountedonthewallorceiling. •Intendedforwatertemperaturesupto+125°Cand10barin standard design. •Colour:grey.Louvresinanodisedaluminium. •CEcompliant. STDT16, thermal contact motor protection Switchesoffthesupplyvoltagetothemotorwhenthethermal contactinthemotorwindingsistripped.Themotorprotector isresetbypressingtheblackbuttonassoonasthemotor windingshavecooledsufficiently.IP55. SWYD1, 2-step change-over switch for air flow (Y/D) Controlstheairflowintwosteps.Onechange-overswitchfor eachunit.IP66. SWST, drip tray Usedtocollectcondensationwhentheunitisusedforcooling. Forinformationaboutotheraccessories,seefanheaterSWH. Accessories - Fan heater SWS Type Description RE1,5 RE3 RE7 T10 TK10 KRT1900 TVV20 TVV25 SD20 STDT16 SWYD1 SWST02 SWST1 SWST2 SWST3 5-step change-over switch for airflow 1,5 A 5-step change-over switch for airflow 3 A 5-step change-over switch for airflow 7 A Room thermostat, IP30 Room thermostat with knob, IP30 Room thermostat, IP55 2-way control valve DN20 2-way control valve DN25 Actuator Thermal contact motor protection, IP55 2-step change-over switch for air flow (Y/D), IP66 Drip tray SWS02 Drip tray SWS12 Drip tray SWS22 Drip tray SWS32/33 55 Fan heaters - water heated Fan heater SWT TheSWTfanheaterisusedforheatingentrances,stores, industrial premises, workshops, sports halls, garages and shops. ThelowheightmeansthatSWTcanalsoberecessedintoa suspended ceiling. TheSWTfanheaterhasarobustdesigninwhiteenamelled steelpanels.SWTisintendedforwaterconnectionandis ceiling mounted. •Installeddirectlytotheceilingorsuspendedfrombrackets. •Intendedforwatertemperaturesupto+80°Cand10bar. •Twofanspeeds. •Colour:white. •CEcompliant. Fan heater SWT (IPX4) Type 2 1 3 1) Fan heater SWT 2) Filter SWTCF 3) Air director SWTCL 4) Extension collar SWTCE 4 Output* Airflow Sound HxWxD Weight level [kW] [m³/h] [dB(A)] [mm] [kg] SWT02 11 1100 53 330x705x535 19 SWT12 18 2000 57 355x825x675 26 SWT22 40 3900 60 415x1135x710 41 *) Applicable at water temperature 80/60 °C, air temperature, in +15 °C SWTCF, filter Withthefilterinstalledtheintervalforcleaningthewatercoil isextended.Thefilterisdeliveredintwopieces. SWTCL, air director Control options Control by thermostat only Toavoiddraughtsatlowceilingheightstheairdirectorcanbe installed to direct air more to the side. -KRT1900orT10/TK10,roomthermostat -TVV20/25,valve+SD20,actuator SWTCE, extension collar 2-step control of airflow only -CB20,controlbox Thermostat and 2-step control -CB20,controlbox -KRT1900orT10/TK10,roomthermostat -TVV20/25,valve+SD20,actuator t 5-step control of airflow only -RE1,5,5-stepregulatormax1,5A,or RE3,5-stepregulatormax3A,or RE7,5-stepregulatormax7A Thermostat and 5-step control -RE1,5,5-stepregulatormax1,5A,or RE3,5-stepregulatormax3A,or RE7,5-stepregulatormax7A -KRT1900orT10/TK10,roomthermostat -TVV20/25,valve+SD20,actuator CB20, control box Controlstheairflowin2steps.Deliveredinencapsulatedbox forwallmounting.Cancontrolseveralunits.Maxinput12A. IP44. RE1,5/RE3/RE7, 5-step change-over switch for air flow Controlstheairflowin5steps.RE1,5 controls maximum 1,5A.RE3controlsmaximum3A.RE7 controls maximum 7A.Tocontroltheheat,asuitablethermostatandavalve+ actuatorareneeded.IP54. 56 AthighinstallationtheoutletcollarfortheSWTcanbe extended.Thisincreasesthethrowpatternoftheair. SWTCE02increasesthethrowpatternto4-7m,SWTCE12 increasesitto5-8mandSWTCE22to7-12m. Accessories - Fan heaters SWT Type Description CB20 RE1,5 RE3 RE7 T10 TK10 KRT1900 RTI2 RTI2V TVV20 TVV25 SD20 SWTCE02 SWTCE12 SWTCE22 SWTCF02 SWTCF12 SWTCF22 SWTCL02 SWTCL12 SWTCL22 Control box 5-step change-over switch for airflow 1,5 A 5-step change-over switch for airflow 3 A 5-step change-over switch for airflow 7 A Room thermostat, IP30 Room thermostat with knob, IP30 Room thermostat, IP55 2-step room thermostat, IP44 2-step room thermostat with knob, IP44 2-way control valve DN20 2-way control valve DN25 Actuator Extension collar 350 mm SWT02 Extension collar 350 mm SWT12 Extension collar 350 mm SWT22 Filter SWT02, 2 pcs Filter SWT12, 2 pcs Filter SWT22, 2 pcs Air director SWT02 Air director SWT12 Air director SWT22 Conditions for sound level measurements, see page 67. Industrial ceiling fan ICF Industrial ceiling fan ICF •Thebladespushdownlargevolumesofairwithoutcausing excessive air speed. •Canoperateclockwiseandanti-clockwise. •Canopywithvibrationabsorption. •Fanbladesanddownrodcoatedwithzinc. •Colour:white,NCSS0505-R90B. •ProtectionclassICF20:IPX0. •ProtectionclassICF55:IPX5. •ApprovedbyIMQandCEcompliant. Control options -CAR15,automaticfanspeedcontrol,formaximum15fans, reversible -CFR1R,5-stepcontrolfor1fan,reversible -RE5,5-stepcontrolforamaximumof12fans -PE1,variablefanspeedcontrolforamaximumof2fans -PE2,5,variablefanspeedcontrolforamaximumof6fans CAR15, automatic fan speed control Automaticfanspeedcontrol,through external sensor, in accordance with variations in the temperature between the ceilingandthefloor.Built-inswitchfor reversedrotation.Controlsamaximumof 15fans.IP33. CAR15 Fan heaters Ceilingfansareusedprimarilytoequalizethetemperature in rooms with high ceilings, such as industrial and warehouse buildings,gymnasiums,andshops.Severalcontrolsaswellas downrodsandbladesofdifferentsizesareavailable,makingit possibletoadaptceilingfanICFtoalmostallapplications. CeilingfanICFpushesthewarmairfromtheceilingand thus lowers the temperature there, the heat losses through the roofandwallsarereducedandinmanycases,heatingcosts canbereducedbyupto30%. CeilingfanICFisahighquality,maintenancefreeproduct withlonglifetime,whichresultsinaveryshortpay-offtime, thatisoftenlessthanoneyear. IndustrialceilingfanICFhasafunctionaldesignandwhite colourwhichblendswellinmostpremises.Thelowsound level makes it even more discreet. CFR1R, 5-step control 5-stepcontrol.Built-inswitchforreversed rotation.Controlsamaximumof1fan. IPX0. CFR1R RE5, 5-step control 5-stepcontrol.Controlsamaximumof12 fans.IP54. Ceiling fan ICF (ICF20:IPX0 / ICF55:IPX5) Type ICF20 ICF55 Voltage [V] 230V~ 230V~ Output [W] 70 70 3 PE1/PE2,5, variable fan speed control Airflow [m³/h] 13500 13500 Height x Ø [mm] 545x1422 545x1422 Weight [kg] 6,2 6,2 Single-phasemanualthyristorforvariable speedadjustmentofthefanandon/off regulation.Externalmounting(IP54)or recessedmounting(IP44).PE1controls amaximumof2fans.PE2,5controlsa maximum of 6 fans. RE5 PE1/PE2,5 Accessories - ICF a a/2 a‘ Type Description CAR15 CFR1R PE1 PE2,5 RE5 CFAP200 CFAP750 CFB900 CFB1200 Automatic fan speed control 5-step fan speed control for 1 fan Stepless fan speed control for 2 fans Stepless fan speed control for 6 fans 5-step fan speed control for 12 fans Short downrod, total height 395 mm Long downrod, total height 945 mm Fan blades Ø 914 mm (3 pcs) Fan blades Ø 1218 mm (3 pcs) a‘/2 Ceiling height (m) Distance between fans a (m) Recommended distance between fans 4 6 8 10 12 5 7 8 9 10 57 Convectors The circulation of air that forms in a room where the air is affected by a heat source is called convection. The air gets warm and rises, then cools and returns to be heated again. Heat disperses effectively while the upward directed warm air stream is utilized to counteract cold draughts from windows for example. Convectors and radiators are simple to install. Our range contains a convector to suit all needs: small, discreet, robust and hard-wearing or quick and economical, all with the same high level of quality. Bench heater SH Mini radiator/Frost guard BenchheaterSHisdesignedforusewithchurchpews,waiting roombenchesandthelike.Thebenchheaterisinstalled undertheseatanddistributesheatintheoccupiedzone through convection and radiant heat. Asheatisproducedassoonastheheaterisswitchedon,SH isalsoanidealandefficientoptioninslowlyheatedbuildings suchaschurches.Onlyheatingthebuildingwhennecessary helps to keep down heating costs. BenchheaterSHhasadiscreetdesignespeciallyadaptedto fit under benches and seats. Theminiradiator/frostguardgivesoffalotofheatdespitethe smallsize.Thecompactradiatorsaresuitableforproviding frostprotection,butcanalsobeusedtoheatmanydifferent areas, for example, homes, close to water pipes, small warehouses, greenhouses and electrical cabinets. Theminiradiator/frostguardisavailableinwhiteor stainlesssteeldesignsandisveryeasytopositiononaccount ofitssmallsize. •Approvedforserialconnection. •Equippedwithproteciongrilleandtubeelementofstainless steel. •Dualreflectors(externalandinternal)givedownwardheat dispersion. •Outerreflectorisofzinc-platedsteelpanelsandtheheateris greylacquered.Colour:NCS4000,RAL7036(grey). •CEcompliant. •Mountedhorizontally(FML/FMLR)orvertically(FMS)onthe wall. •Stainlesssteeltubularelement. •Equippedwith1metrelongcordwithplugforconnectionto an earthed outlet socket. •Integratedoverheatingprotection. •Integratedthermostatwithsettingrange+5–+35°C. •Colourfront:NCS1103-Y06R(white).FMLR200hasa stainless steel design. •CEcompliant. Bench heater (IP21) Frostguard FMS, FML, FMLR (IP31) Type SH17521 SH17531 SH25021 SH25031 SH37521 SH37531 58 3 Voltage [V] 230V~ 400V2~ 230V~ 400V2~ 230V~ 400V2~ Heat output [W] 175 175 250 250 375 375 LxHxD [mm] 700x100x200 700x100x200 1000x100x200 1000x100x200 1500x100x200 1500x100x200 Weight [kg] 1,4 1,4 1,9 1,9 2,9 2,9 Type FMS200 FMLR200 FML200 FML300 FML450 Voltage [V] 230V~ 230V~ 230V~ 230V~ 230V~ 3 Heat output [W] 200 200 200 300 450 LxHxD [mm] 90x298x68 298x90x68 298x90x68 398x90x68 498x90x68 Weight [kg] 0,7 0,7 0,7 0,9 1,1 Convectors TWTC TWT Ribbed pipe radiator Thermowarm Frico's ribbed pipe radiators are designed for harsh environments and are approved for wet rooms, but are also availableindesignsforroomsatriskoffire.Theretrodesign has also created a new application area in modern housing. Frico's ribbed pipe radiators have a hard wearing and robust designindarkgreensheetsteel.Thecompactformatmeans the radiator has a small footprint, but gives a lot of heat. Thermowarmisaseriesofeasilyinstalledconvectorsdesigned for public buildings such as changing rooms, stores and toilets.TWTCcanalsobeusedincorrosiveandaggressive environments.TWT200hasasurfacetemperatureaslow as60°C,whichmakesitidealfordaycarecentresand bathrooms. Thermowarmiseasytopositionandhas,despiteitssmall size,alargeheatoutput.Thethreedifferentsurfacefinishes: white,greycoveredpanelcoveredandstainlesssteel,make Thermowarmsuitableformostenvironments.Thefront cover can be opened making it straightforward to keep the convectorscleanandtidy. Ribbed pipe radiator (IP44) Type 125-12B 125-22B 125-32B 125-42B 126-32B 126-42B 126-52B 127-22B 127-42B Voltage [V] 230V~ 230V~ 230V~ 230V~ 230V~ 230V~ 230V~ 230V~ 230V~ TWT100 (IP44) white, with circuit breaker 3 Heat output [W] 200 375 575 775 575 775 1150 500 800 •Withribbedflangesandtubularelements. •Integratedthermostatwithsettingrange0–+35°C. •Resettableoverheatingprotectionalongthefulllengthofthe convector. •ColourTWT100andTWT300:whitefront,RAL9016, NCS0500,greysides ColourTWT200:greycoveredfrontpanel,greysides ColourTWTC:stainlesssteeldesign,blacksides •CEcompliant. LxHxD [mm] 370x180x185 530x180x185 730x180x185 880x180x185 730x180x185 880x180x185 1185x180x185 980x180x185 1925x180x185 Weight [kg] 2,4 3,3 4,5 5,5 4,7 5,7 7,5 10,9 33,3 Type TWT10321 TWT10331 TWT10521 TWT10531 TWT11021 TWT11031 Voltage [V] 230V~ 400V~ 230V~ 400V~ 230V~ 400V~ Heat output [W] 300 300 500 500 1000 1000 3 LxHxD [mm] 345x205x123 345x205x123 465x205x123 465x205x123 765x205x123 765x205x123 TWT200 (IP44) covered front, with circuit breaker 60 °C Type TWT20321 TWT20331 TWT20521 TWT20531 TWT21021 TWT21031 Voltage [V] 230V~ 400V~ 230V~ 400V~ 230V~ 400V~ Heat output [W] 300 300 500 500 1000 1000 TWT30321 TWT30521 TWT31021 Voltage [V] 230V~ 230V~ 230V~ Heat output [W] 300 500 1000 Weight [kg] 1,5 1,5 2,0 2,0 3,0 3,0 3 LxHxD [mm] 345x205x123 465x205x123 765x205x123 TWTC (IP54) stainless steel, with mains cord and plug Type 3 LxHxD [mm] 345x205x123 345x205x123 465x205x123 465x205x123 765x205x123 765x205x123 TWT300 (IP21) white, with mains cord and plug Type Weight [kg] 1,5 1,5 2,0 2,0 3,0 3,0 Convec tors •Theribbedpiperadiatorisavailableinthefollowingdesigns: -Model 125, without output selector. -Model 126, with output selector that regulates the heat in three steps. -Model 127,withoutoutputselector,sand-filledand suitable for rooms at risk to fire. •Theribbedflangesincreasetheheatingsurfaceandprovide good heat transfer combined with a compact design. •Resettableoverheatingprotectionalongthefulllengthofthe ribbed pipe radiator. •Aprotectivesteelcasegivealowersurfacetemperatureand extraprotectionagainstimpact(model125and126). •Colour:darkgreen,RAL6005,NCS7020-B90G. •CEcompliant. Weight [kg] 1,5 2,0 3,0 3 TWTC30321 Voltage [V] 230V~ Heat output [W] 300 LxHxD [mm] 345x205x123 Weight [kg] 1,5 TWTC30521 230V~ 500 465x205x123 2,0 TWTC31021 230V~ 1000 765x205x123 3,0 59 Convectors Fan convector PF FanconvectorPFissuitableformostenvironments,for example, homes and offices. It is also ideal for use in buildings thatarerarelyused,forexample,weekendcottages,where quickheatingisrequired.Thefanconvectoralsohasvery gooddryingproperties.Modelsupto800Whaveasurface temperature of less than 60°Cwhichmakesthemextremely suitablefordaycarecentresandbathrooms. Thefanconvectorconsumeslessenergythanstandard convectors.Theairflowfromtheconvector,whichbalances the temperature difference between the floor and ceiling, gives higherefficiencyandlowerenergyconsumptioncomparedto convectors without a fan. FanconvectorPFhasanattractiveandcleandesignina whitefinish.Abrushedaluminiumfrontisavailableasan accessory.Thelowsurfacetemperaturemakesitpossible tofinishthefrontpanelinanycolourorafilmfinishcanbe applied. •FanconvectorPFisavailableinthefollowingdesigns: -PFE is equipped with a 1.2 metre long cord with plug for connectiontoanearthedoutletsocket(230V~).Canbe used as a portable unit, a floor stand is available as an accessory. -PFDisdesignedforpermanentinstallation(400V2~). -PFWisforwaterbasedheating.Equippedwitha1.2 metre long cord with plug for connection to an earthed outletsocket.Suppliedwithtwo,0.9mPEXhosesforeasy installation.Workswithaheatpump. •Lowsoundlevel. •Master/slavefunction(PFE/PFD). •Integratedthermostatwithsettingrange5–+35°C(PFE/ PFD). •Preparedfornighttariffsviaexternalsignal(PFE/PFD). •DepthwallbracketPFE/PFD:30mm. •DepthwallbracketPFW:45mm. •Colour:white,RAL9016,NCS0500(standard),brushed aluminiumasanaccessory. •CEcompliant. 60 Fan convector PFE/PFD, electrically heated (IP23) Type PFE5 PFE8 PFE10 PFE12 PFD5 PFD8 PFD10 PFD12 Voltage [V] 230V~ 230V~ 230V~ 230V~ 400V2~ 400V2~ 400V2~ 400V2~ Heat output [W] 500 800 1000 1200 500 800 1000 1200 Fan convector PFW, water heated (IP23) Type Voltage 3 LxHxD [mm] 598x330x90 598x330x90 598x330x90 598x330x90 598x330x90 598x330x90 598x330x90 598x330x90 Weight [kg] 6 6 6 6 6 6 6 6 2 Airflow Sound LxHxD Heat Weight level*2 output*1 [kW] [V] [m3/h] [dB(A)] [mm] [kg] PFW10 230V~ 1,1 59 42/32 598x330x90 7,3 PFW20 230V~ 3,0 65 44/33 1058x330x90 13 *1) Applicable at water temperature 80/60 °C, air temperature, in +20 °C. *2) Conditions: Distance to the unit: 3 metres. Directional factor: 2. Equivalent absorption area: 200 m2. Accessories - PFE/PFD/PFW Type Description PFFAL PFFS Front, brushed aluminium Floor stand PFE/PFD Dehumidifier/Hand dryer Dehumidifier LAF10 Hand dryer HD2C LAF10isadehumidifierthatreducessurplusmoistureatthe sametimeasitprovidesadditionalheattotheroom.The dehumidifierisalsoidealforuseinareasfrequentlyexposed to moisture, for example, basements, warehouses, washrooms, and sports halls or after minor water damage. LAF10isveryeasytouseandhaslowpowerconsumption. Withacontrolledhumidityyoureducetheriskofmoisture damage indoors that can be expensive to repair. Withitsstraightforwarddesignandneutralfinish,LAF10is suitableformostenvironments.Itscastorsandcarryinghandle makeiteasytomoveandplace. HD2Cisahanddryerofmoderndesigninstainlesssteel intendedtobeinstalledinpublicsanitaryareassuchasrest roomsanddressingrooms.Nopapertowelwasteandthe premises are kept nice and clean. HanddryerHD2Chasastainlesssteelhousingofmodern designandiseasytokeepclean.Theroundedtopmakesit impossibletoputobjectsonthehanddryer. •Dehumidifyingcapacity: 5litres/dayattheconditionRT27°C,RH60%. 10litres/dayattheconditionRT30°C,RH80%. •Inbuiltfilter. •Automaticdefrosting. •Inbuiltcollectioncontainerwithlevelguardandindicator lamp. •Adjustablehygrostat(30-80%relativehumidity). •Twofanspeeds. •Equippedwitha2metrelongcordwithplugforconnection to an earthed outlet socket. •Operatingtemperaturerange:8-35°C •Powerconsumption:220W •Refrigeranttype(Freon-free):R134a •DimensionsHxWxD:550x270x364mm •Weight:13,5kg •Colour:white,Pantone428C. •ApprovedbyTÜVandCEcompliant. •Highairspeedandhighoutputgivesashortdryingtime. •Built-inthermocontactwithautomaticresetprotectsfrom overheating. •HD2Cstartswhentheuser’shandsare5-10cmunderthe appliance(photocellwithadjustablesensitivity).Stops2-3s afterthehands’removal. •Solidhousingin1.2mmstainlesssteel. •DimensionsHxWxD:322x260x148mm. •CEcompliant. Hand dryer HD2C (IPX3) Type HD2C Output [W] 2125 Airflow [m3/h] 150 Airspeed [m/s] 28 Amperage Weight [A] [kg] 9,2 4,0 Type Voltage Air flow LAF10 [V] 230V~ [m3/h] 90/115 Sound level*1 [dB(A)] 40/45 Amp*2 Weight [A] 1,0 [kg] 13,5 *1) Conditions: Distance to unit 3 metres. *2) Applicable at water temperature 20 ºC. Capacity (litres/day) Type LAF10 At 30°C 80%RH 10,0 At 27°C 60%RH 5,0 At 20°C 60%RH 4,0 Convec tors Dehumidifier LAF10 (IP21) At 8°C 60%RH 1,8 61 Thermostats and controls The control system is the intelligent centre and the ”brain” of a heating system and essential for good comfort level and low energy consumption. The temperature of an electric heating system can be quickly, easily and precisely regulated and is more responsive than any other heating system. Frico offers a wide range of thermostats and controls, read more under each product or in the Frico catalogues. T10 TKS16(400) TK10 TD10 RTI2 T, TK, TD, basic offer thermostats RTI, electronic 2-step thermostats Processorcontrolledthermostatsforroom/floorheating. Availablewithconcealed/visibleknobordigitaldisplay.Model withvisibleknobalsoavailablewithswitchandin400V. On/offcontrol(forslowsystems)orproportionalcontrol(for fastersystems)inthesamethermostat.TD10hasadjustable P-bandandtimeofcycle. Internaland/orexternalsensors(externalsensorRTS01 availableasanaccessory)givethepossibilityofselectingthe sensorfunctione.glimitingexternalsensors(min/max).Save reductioneitherbybuilt-inmanualswitchorviaexternal timer.CEcompliant. Processorcontrolled2-stepthermostatsforroomheating/ cooling.Availablewithconcealedorvisibleknob.Adjustable temperaturedifferencebetweenthesteps(1–10degrees). Savereductionviaexternalconnectiontimer(1–10degrees). Externalsensor(RTS01)availableasanaccessory. Highprotectionclass(IP44).CEcompliant. Type T10 TK10 TKS16 TKS16400 TD10 62 RTI2V Voltage [V] 230~ 230~ 230~ 400V2~ 230V~ Max input [A] 10 10 16 16 10 Setting range [°C] 5 - +30 5 - +30 5 - +30 5 - +30 5 - +37 HxWxD [mm] 80x80x31 80x80x31 80x80x39 80x80x39 80x80x31 Type RTI2 RTI2V Voltage [V] 230V~ 230V~ Setting range [°C] 5 - +35 5 - +35 Accessories Type Description RTS01 External floor/duct sensor HxWxD [mm] 155x87x43 155x87x43 Thermostats and controls KRT1900/1 KRTV19 TBK10 KRT2800 TBKS10 KRT, capillary tube thermostats TBK, bimetal thermostats Capillarytubethermostatsforroomheating/cooling.Available with concealed and visible knob, and control in 1 or 2 steps. KRT2800controlsin2stepsandhasadjustabletemperature differencebetweenthesteps(1–4degrees).KRT1901hasa temperaturerangeof-35–+10°C.Highprotectionclass(IP44 resp.IP55).CEcompliant. Mechanicalbimetalthermostatswithaccelerationresistance forroomheating/cooling.TBKS10alsohasa1-poleswitch. CEcompliant. Type Voltage [V] 230/400V~ 230/400V~ 230/400V~ 230/400V~ KRT1900 KRT1901 KRTV19 KRT2800 Setting range [°C] 0 - +40 -35 - +10 0 - +40 0 - +40 Type Voltage [V] 230V~ 230V~ TBK10 TBKS10 HxWxD [mm] 165x57x60 165x57x60 165x57x60 165x57x60 Setting range [°C] 5–30 5–30 CBT HxWxD [mm] 80x80x43 80x80x43 KUR CBT, electronic timer KUR, digital time switch Electronictimerwithalternatingcontact.Settingrange1/2-12-4or4-8-16-24hoursrespectively.Thesettingrangecanbe limiteddowntoamaximumtimeof1/2hours.IP44. Digitalweeklytimerwith8differentprogramsteps(36 memoryplaces)equippedwithachangeovercontact.Max. breakingcurrent:10A.IP55. Type Voltage [V] 230V~ CBT Type Voltage [V] 230V~ KUR HxWxD [mm] 175x85x105 Thermostats Basic offer T10 TK10 Electronic 2-step TKS16 TD10 TKS16400 RTI2 KRTV19 KRT2800 TBK10 TBKS10 X X X X X X X X X X X Internal sensor X X X X X X X*¹ X*² X*¹ X*² X*¹ X*¹ X*¹ X*¹ X*² X*² X*² X*² X X X X X 1-pole switch Volt free contact X X Contact, 1-pole closing X X X X X Contact, 1-pole alternating X Internal setting X Processor controlled X X X X X X X Capillary tube Adjustable temp.diff. between the steps *¹) External sensor (RTS01) as accessory. *²) Can be used with an external timer. *³) See manuals on www.frico.se. X X X X X X X X Bimetallic 2-step X X Advanced extra functions*³ Fits wall box system X X Digital display Heating or cooling function Bimetallic RTI2V External sensor Save reduction Capillary tube KRT1900 KRT1901 Ther mos t at s and c ontrols Functions | HxWxD [mm] 155x87x43 X X X X X X X X X X X X X X X X X X X X 63 Water control VOS VOSP TBVC SD230 AV BPV10 VMO TBVCMP SD230 AV TBVCM SDM24 TBVCMP SDM24 AV ST23024 AV ST23024 BPV10 VOT VMOP VMT Completevalvekitswithmultifunctionalterminalvalvesmakes new functions possible and ensures stable flows and exact control usingthemodulatingactuator.Theyaresuppliedatdifferentlevels andhavealowinstallationcostwithfewcomponents.Thevalve kitgivesexactadjustmentandmeansextraenergysavings.Usedto controlthewatersupplytowaterheatedunitswithcontrolsystem SIRe. Used with SIRe Basic and Competent Used with SIRe Advanced VOS, valve kit on/off VMO, modulating valve kit Twowaycombinedcontrolandadjustmentvalvewithon/off actuator,shut-offvalveandbypass.DN15/20/25.230V.Used withSIReBasicandCompetent. Thevalvekitconsistsofthefollowing: •TBVC,regulationandadjustmentvalve •SD230,actuatoron/off230V •AV,shutoffvalve •BPV10,bypassvalve Twowaycombinedcontrolandadjustmentvalvewith modulatingactuatorandshut-offvalve.DN15/20/25.24V.Used withSIReAdvanced. Thevalvekitconsistsofthefollowing: •SDM24,modulatingactuator24V •TBVCM,regulationandadjustmentvalve •AV,shutoffvalve •ST23024,24Vtransformerforvalveactuator(invalvekit with24V) VOSP, pressure independent valve kit on/off Twowaypressureindependentcontrolandadjustmentvalve withon/offactuator,shut-offvalveandbypass.DN15/20/25. 230V.UsedwithSIReBasicandCompetent. Thevalvekitconsistsofthefollowing: •TBVCMP,pressureindependentregulationandadjustment valve •SD230,actuatoron/off230V •AV,shutoffvalve •BPV10,bypassvalve VOT, three way control valve and actuator on/off VMOP, pressure independent and modulating valve kit Twowaypressureindependentcontrolandadjustmentvalve withmodulatingactuatorandshut-offvalve.DN15/20/25.24V. UsedwithSIReAdvanced. Thevalvekitconsistsofthefollowing: •TBVCMP,pressureindependentregulationandadjustment valve •SDM24,modulatingactuator24V •AV,shutoffvalve •ST23024,24Vtransformerforvalveactuator(invalvekit with24V) DN15/20/25.230V.UsedwithSIReBasicandCompetent. VMT, three way control valve and modulating actuator DN15/20/25.24V.UsedwithSIReAdvanced. 64 Type Flow Connection Kvs Type Flow Connection Kvs VOS15LF VOS15NF VOS20 VOS25 VOSP15LF VOSP15NF VOSP20 VOSP25 VOT15 VOT20 VOT25 Low flow Normal flow Normal flow Normal flow Low flow Normal flow Normal flow Normal flow Normal flow Normal flow Normal flow DN15 DN15 DN20 DN25 DN15 DN15 DN20 DN25 DN15 DN20 DN25 0,90 1,8 3,4 7,2 1,7 2,5 4,5 VMO15LF VMO15NF VMO20 VMO25 VMOP15LF VMOP15NF VMOP20 VMOP25 VMT15 VMT20 VMT25 Low flow Normal flow Normal flow Normal flow Low flow Normal flow Normal flow Normal flow Normal flow Normal flow Normal flow DN15 DN15 DN20 DN25 DN15 DN15 DN20 DN25 DN15 DN20 DN25 0,40 1,0 2,0 4,0 1,7 2,5 4,5 Water control TBVCMP AV BPV10 SD230 SDM24 VAT TBVC/TBVCM, regulation and adjustment valve BPV10, by-pass valve Theregulationandadjustmentvalvecanbeusedtofinely adjustorshutoffthewaterflowmanually.Thewaterflowis setusingtheadjustmenttool(option).Theregulationand adjustment valve also has a shut off function, which makes maintenance easier, and a self sealing measurement outlet whichallowsforeasyandfastmeasurements. Ifthevalveisclosed,alowflowpassesthroughtheby-pass valve(BPV10)sothatthereisalwayshotwaterinthewater coil.Thisistoprovidequickheatsupplywhenadooris opened but also to provide a degree of frost protection. TBVCMP, regulation and adjustment valve Theregulationandadjustmentvalvecanbeusedtofinely adjustorshutoffthewaterflowmanually.TBVCMPis independent of the available differential pressure, which contributestostableandaccurateregulation(ensuresthe correct flow to the heater even if the differential pressure in therestofthepipesystemchanges).Thewaterflowisset usingtheadjustmenttool(option).Withtheregulationand adjustmentvalveeasyflush-throughisalsopossible,which makesforeasyandfastmaintenance. AV, shut off valve SD, actuator Theactuatorcontrolstheheatsupplyon/off.Inunpowered modeSD230isopen. SDM24, actuator Theactuatorismodulatedandgivesthecorrectheat.SDMcan besettoalwaysallowasmallleakageflowthrough.Thisisto providequickheatsupplywhenadoorisopenedbutalsoto provide a degree of frost protection. VAT, adjustment tool for valve kit VOS, VOSP, VMO, VMOP Withtheadjustmenttoolthewaterflowcanbeaccuratelyand easilyset. Fan heaters TBVC/TBVCM Theshutoffvalveconsistsofaballvalvewhichiseitheropen or closed and is used to shut off the flow, when servicing for example. 65 Water control VR20/25 JVF20/25 TRV20/25 VR20/25 VR20/25 AV20/25 BPV10 AV20/25 AV20/25 JVF20/25 BPV10 JVF20/25 BPV10 TRV20/25 SD20 TRV20/25 SD20 T10/KRT SD20 TVV20/25 T10/KRT °C 230V ~ SD20 230V ~ TVV20/25 SD20 SD20 T10/KRT T10/KRT °C °C 230V ~ VR 20/25, valve kit For control of water flow to water heated air curtains. Thevalvekitconsistsofthefollowing: •AV20/25,stopvalve •JVF20/25,adjustmentvalve •TRV20/25,on/off3-waycontrolvalve •BPV10,by-passvalve •SD20,actuatoron/off230V~ Thestopvalve(AV20/25)consistsofaballvalvewhichis either open or closed. It is used to turn the water flow off andon.Thewaterflowcanbefine-tunedmanuallywiththe adjustmentvalveandcanalsobecompletelyturnedoff.The waterflowmaybereadoffthevalve.ThekvvalueforJVF20is 3,5andforJVF25itis5,5. Ifthe3-wayvalve(TRV20/25)isclosed,theflowthroughthe by-passvalve(BPV10)islowtoensurepresenceofwarmwater intheheatingcoil.Thisleadstoinstantheatsupplywhen neededandsomedegreeoffrostprotection.Theactuator (SD20)workson/off. Thevalvekitisavailablewithtwodifferentvalve dimensions:VR20-DN20(3/4”)andVR25-DN25(1”).The by-passvalvedimensionisDN10(3/8”).ToregulateVR20/25, a suitable thermostat has to be added. TVV20/25 °C 230V ~ TVV20/25, valves + SD20, actuator TVV20/25,2-wayregulationvalveandSD20,actuatoron/ off provides a basic form of water regulation, without the possibilityofadjustingorshuttingthewaterflowoff,e.g. whenmakingmaintenance.Asuitablethermostatischosento regulateTVV20/25andSD20.DN20/25. TVV20/25, 2-way control valve TVV20hasapipedimensionofDN20(3/4”)andTVV25of DN25(1”).PressureclassPN16. Maximumpressure2MPa(20bar). MaximumpressuredropTVV20:100kPa(1bar) MaximumpressuredropTVV25:62kPa(0,62bar) Thekv-valueisadjustablein3steps: TVV20:kv1,6,kv2,5andkv3,5 TVV25:kv2,5,kv4,0andkv5,5 TRV20/25, 3-way control valve Ifa3-wayvalveispreferred,TRV20/25canbeusedinsteadof TVV20/25. SD20, actuator on/off 230V~ SD20regulatestheheatsupply.Workson/off.A5second closing of the valve prevents sudden pressure changes in the pipesystem.Protectionclass:IP40. TE3434 Flexiblehose,length0,8metres,forwaterheatedunits(2is neededforaunit)withexternalthread3/4”(DN20)atoneend andcouplingnutinternalthread3/4”(DN20),ontheother. TheseproductsshouldnotbeusedtogetherwithcontrolsystemSIRe. 66 Technical data Symbols for model types = normal design (no symbols), IPX0 = drip-proof design, IPX1 = splash-proof design, IPX4 = jet-proof design, IPX5 Protection classes for electrical material Heat insulation, U-value U = thermal transmittance value [W/m²°C] U-values indicate the heat insulating capacity of a building section. Material U-value [W/m² °C] IP, first figure Protection against solid objects 0 No protection Walls 1 Protection against solid objects ≥50 mm New building 2 Protection against solid objects ≥12,5 mm Wooden fascia with 15 cm insulation and plaster 0,27 3 Protection against solid objects ≥2,5 mm Wooden fascia with 20 cm insulation and plaster 0,25 4 Protection against solid objects ≥1,0 mm Wooden fascia with 25 cm insulation and plaster 0,22 5 Protection against dust Brick fascia with 15 cm insulation and plaster 0,27 6 Dust-tight Brick fascia with 20 cm insulation and plaster 0,24 Light concrete with 15 cm insulation 0,25 IP, second figure Protection against water Light concrete with 20 cm insulation 0,2 0 No protection Sheet metal fascia with 5 cm insulation 0,8 1 Protection against vertically dripping water Sheet metal fascia with 10 cm insulation 0,4 2 Protection against dripping water angled at max 15° Sheet metal fascia with 15 cm insulation 0,3 3 Protection against sprinkled water New construction for low energy house 0,18 4 Protection against spraying with water Warehouse 0,3 5 Protection against water jets One layer PVC (900 g) 5,0 6 Protection against heavy seas Insulated hall (Thermohall) 0,6 7 Protection against short-term immersion in water Older building 8 Protection against the effects of long-term immersion in water Single brick 12 cm 1,8 1 1/2 brick 18 cm 1,1 Light concrete block 20 cm 0,8 Light concrete block 30 cm 0,6 Concrete 15 cm 2,8 Concrete with 5 cm insulation 0,8 Concrete with 10 cm insulation 0,4 Frame wall with 5 cm insulation 0,8 Frame wall with 10 cm insulation 0,4 Frame wall with 15 cm insulation 0,3 New construction 0,3 How is sound measured? Sound level is measured in decibels (dB). The dB is a logarithmic unit used to describe a ratio. If the sound level is increased by 10 dB, the result is twice as loud (as perceived by human ear). It is also useful to know that two equally strong sound sources give an added sound level of 3 dB. Assume you have two entrances with two air curtains in each entrance, all four units with a sound level of 50 dB. The total sound level will then be 56 dB. The first opening will have a total sound level of 53 dB plus an extra 3 dB from the other opening. Roof New building Sheet metal pitched roof, with 20 cm insulation 0,24 Brick pitched roof, with 20 cm insulation 0,23 Older building Points of reference – dB Concrete beam frame 15 cm 2,8 0 The softest sound a person can hear Concrete beam frame with 5 cm insulation 0,8 10 Normal breathing Concrete beam frame with 10 cm insulation 0,4 30 Recommended max. level for bedrooms Light concrete 20 cm 0,8 40 Quiet office, library Light concrete 30 cm 0,6 50 Large office Sheet metal roof, uninsulated 4,0 Sheet metal roof with 5 cm insulation 0,8 60 Normal conversation Sheet metal roof with 10 cm insulation 0,6 80 Ringing telephone Sheet metal roof with 25 cm insulation 0,2 85 Noisy restaurant Windows 110 Shouting in ear 120 The threshold of pain The sound level is stated for most of our product in the mini catalogue. Our sound measurements are done according to international standards BS 848, AMCA standard 210-85 and DIN 24 163, (the distance to the product* 5 metres, directional factor 2, equivalent absorption area 200 m²). *) For fan heaters Tiger, Cat and Panther as well as convector PF, the distance to the product is 3 metres. New building 1+1 pane window (1 outer pane and 1 insulated pane) 2,5 2 pane window (2 insulated panes) 2,7 2+1 pane window (1 outer pane and 2 insulated panes) 1,0 3 pane window (3 insulated panes) 1,2 Energy class A 0,9 Energy class B 1,0 Energy class C 1,1 Energy class D 1,2 Energy class E 1,3 Energy class F 1,4 Energy class G 1,5 Older building 1 pane window 5,0 2 pane window 3,0 3 pane window 2,0 3 pane window insulation pane 1,8 67 Frico AB Box 102, SE-433 22 Partille Sweden T + 46 31 336 86 00 F + 46 31 26 28 60 [email protected] • www.frico.se