air curtains radiant heaters fan heaters convectors thermostats

Transcription

air curtains radiant heaters fan heaters convectors thermostats
Mini catalogue 2012
air curtains
radiant heaters
fan heaters
convectors
thermostats
For comfortable energy efficient indoor climate.
Welcome
News
… to the 2012 edition of the Frico Mini
Catalogue.
At Frico we are proud to be able to offer
energy-efficient products for a better indoor
climate. In our products, the focus is on
achieving the greatest possible function with
the least possible energy consumption – without
compromising on our core values of trust,
competence and design.
We hope this Mini Catalogue will be a useful
tool when choosing the correct product for
each application. For more extensive product
information, we welcome you to visit our
website, www.frico.se, where all technical
information regarding our products is available.
Together with company and product news, 3D
models of our products, specifications texts,
output calculation guide and much more,
www.frico.se is the ideal source for full
information regarding Frico’s product range.
Looking forward to hearing from you!
1
No
PA 3500/4200
Adaptable air curtains for installation
heights up to 3,5 / 4,2 metres
2
No
Carboninfra IC
For fast and gentle heat
with flexible installation
3
No
UF600
Air curtains that blow from
below for large doorways
Pontus Grimberg
International Sales Manager
Managing director
Jonas Valentin
Managing Director
T: +46 31 336 86 04
F: +46 31 26 28 25
[email protected]
International Sales
Sales support
Pontus Grimberg
Jan-Erik Lundholm
International Sales Manager
T: +46 31 336 86 35
F: +46 31 26 28 25
[email protected]
International Area Manager
T: +46 31 336 86 13
F: +46 31 26 28 25
[email protected]
Hossein Mohrsazha
Raimund Schüpp
International Area Manager
T: +46 31 336 86 45
F: +46 31 26 28 25
[email protected]
International Area Manager
T: +44 787 59 77 517
F: +46 31 26 28 25
[email protected]
Yvonne Stenholm
Sales Support Manager
T: +46 31 336 86 16
F: +46 31 26 28 25
[email protected]
Lena Majqvist
Sales Support
T: +46 31 336 86 38
F: +46 31 26 28 25
[email protected]
Ingvor Thomsson
Björklund
Technical support
2
Do not hesitate to contact us!
Mo - Fr 8.00 - 17.00 CET
T +46 31 336 86 00
F +46 31 26 28 60
[email protected]
Marketing and Sales
Coordinator
T: +46 31 336 86 06
F: +46 31 26 28 25
[email protected]
Björn Sandqvist
Susanne Andersson
Technical Support Manager
T: +46 31 336 86 14
F: +46 31 26 28 60
[email protected]
Technical Support
T: +46 31 336 86 17
F: +46 31 26 28 60
[email protected]
Martin Ekman
Adam Balogh
Stephan Hansson
Technical Support
T: +46 31 336 86 34
F: +46 31 26 28 60
[email protected]
Technical Support
T: +46 31 336 86 10
F: +46 31 26 28 60
[email protected]
Quality Manager
T: +46 31 336 86 10
F: +46 31 26 28 60
[email protected]
Cover: The new Opera house in
Oslo, Norway. Photo: Erik Berg
Air curtain AD200W (more information
about that product on p 11) creates
a comfortable indoor climate in this
spectacular building.
6
Thermozone® Air curtains
32
Radiant heaters
Thermozone guidelines
35 Thermoplus EC 3
10
Thermozone AD100 3, ADA 1
36 Thermocassette HP 3
11
Thermozone AD200 1 3 2
36 Elztrip EZ100 3
12
Thermozone AR200,
recessed 3 2 1
37 Elztrip EZ200 3
13
Thermozone AR3500,
recessed 3 2
38 Infrared heater IR 3
14
Thermozone AR300,
recessed 3 2
39 Infrared heater CIR 3
7
37 Elztrip EZ300 3
38 Infrared heater IRCF 3
15
Thermozone Portier 1 3
39 Infrared heater ELIR 3
16
Thermozone AC Corinte 1 3 2
40 Infrared heater IH 3
17
Thermozone AD Corinte 1 3 2
41 Infrared heater IC 3
Thermozone SF,
for circular/revolving doors 3 2
42 Comfort Panel SZR,
water heated, recessed 2
Thermozone RD,
for circular/revolving doors 3 2 1
43
18
19
20 Thermozone AD300 1 3 2
21
Thermozone AD400 1 3 2
22 Thermozone PA3500 1 3 2
Comfort Panel SZ,
water heated 2
44 Controls ERP, CIRT, S123
57
57
58
Ceiling fans
Ceiling fan ICF 3
Convectors
58
Benchheater SH 3
58
Frostguard FML 3
59
Ribbed pipe radiator 3
59
Thermowarm TWT, TWTC 3
60
Fan convector PFE, PFD 3
61
61
Fan convector PFW,
waterheated 2
Other products
61
Dehumidifier LAF10 3
61
Hand dryer HD2C 3
62
Thermostats and controls
62
Room ther mostats T, TK, TD
62
2-step room thermostats RTI2,
RTI2V
46 PA1006, doorheater
63
Capillary tube thermostats KRT
46 K21, 2 kW 3
63
Bimetal ther mostats TBK
63
Timer CBT, digital time switch
KUR
64
Water contr ols VOS, VOSP, VOT,
VMO, VMOP, VMT
66
Water contr ols VR20/25,
TVV20/25, SD20
45
Fan heaters
22
Thermozone PA4200 1 3 2
24
Thermozone AG4500/5000 1 2
25
Thermozone AC500 1
47 Tiger,
2-9 kW, 15 kW, 20 and 30 kW 3
25
Thermozone UF60 0 1
48 Cat, 3-9 kW 3
26 Thermozone AGI 1 2
49 Elektra C/F/V/H 3
27 Thermozone ADA Cool,
cold storage 1
50 Panther,
6-15 kW, 20 and 30 kW 3
28 Control system SIRe
52 SWH, water heated 2
30 Controls ADEA, CB, ADSR54, RTRD
55 SWS, water heated 2
31 Other accessories
56
67
Technical guide
SWT, ceiling mounted,
waterheated 2
Design and specifications are subject to
change without notice. See www.frico.se
for latest updated info.
Frico products
Today’s high and increasing energy prices often make heating costs substantial. Frico strives to develop products
and systems that provide energy saving heating solutions and better heating comfort at the same time. Reducing
energy losses and making optimum use of the heat is also important. Air curtains in doorways and openings,
radiant heaters or ceiling fans where the ceiling is high are examples of products that contribute to large energy
savings.
Air curtains
It makes sound economic sense to create an
efficient and invisible door that keeps the heat
inside. Air curtains can be even more effective
when used in air conditioned or cold storage
buildings.
Thermozone technology with its precisely
adjusted air velocity gives even protection
throughout the opening. Frico air curtains
provide the most efficient separation with the
lowest possible energy consumption, regardless
of whether it is the heat or the cold that you
want to keep inside.
Radiant heaters
Frico radiant heaters imitate the sun, the most
comfortable and efficient heat source available.
The heat is emitted only when the rays hit a
surface and the room temperature can thus be
lowered while occupants experience a comfortable
environment. This makes radiant heaters well
suited not only for total heating but also for
zone and spot heating, for example to avoid cold
draughts from windows.
Radiant heaters are easy to install and require
minimum maintenance. They heat directly when
switched on and give no air movement.
Fan heaters
We are proud of the worldwide fame Frico fan heaters
have gained. They are reliable and are designed for long
life. Our range covers all needs. The investment cost is
low compared to other heating systems.
A great advantage of fan heaters is the option of
combining heating and ventilation. Frico fan heaters are
compact, silent and light weight. They are available for
electrical heating as well as for water heating.
Convectors
The circulation of air that forms in a room
where the air is affected by a heat source is
called convection. The air gets warm and rises,
then cools and returns to be heated again. Heat
disperses effectively while the upward directed
warm air stream is utilized to counteract cold
draughts from windows for example.
Thermostats and controls
Ceiling fan
Ceiling fans push down overheated air from the
ceiling to the living area. Losses are decreased
and the heat is used to best effect.
The key to energy efficient heating and good
comfort is the combination of heating products
and good controls.
Frico offers a wide range of thermostats and
controls, read more under each product or in the
Frico Catalogues.
More information
More information on Frico and Frico products
can be found on our website www.frico.se,
in our main catalogues and other printed
material that you can order from us or from our
distributors.
4
Good reasons to choose Frico
More than 75 years of experience of developing
products for the varied Nordic climate has provided us
with a unique knowledge bank. This is our foundation
when creating today's energy efficient solutions for a
comfortable indoor climate.
Leading technique and design
Frico is the leading supplier of air curtains, radiant heaters and
fan heaters in Europe. All our products are well designed in
good Scandinavian tradition.
Knowledge and resources
Since we develop our own products, our knowledge on how to
create an energy efficient indoor climate is constantly growing.
We have one of Europe's most modern and advanced air and
sound laboratories to aid us.
Qualified local support
Frico is present locally in some 70 countries worldwide with
a network of wholly-owned subsidiaries and independent
distributors. Our highly qualified representatives are carefully
chosen and together we are able to provide you with the best
possible support. To find your nearest Frico subsidiary or
distributor, please visit www.frico.se.
Frico Academy
The Academy is an important platform for networking and
sharing inspiration and knowledge between us and our
distributors around the world. Through the Frico Academy
we share our knowledge on theory and technology, as well
as product knowledge and experience in manufacturing and
product development.
Quality and long life
Frico offers consistent and high product quality. Our product
warranty is there for your safety. It covers manufacturing faults
and is valid for five years and necessary components will be
replaced.
Frico products are designed for long life and are easy to
maintain. Through our distribution network we provide
reliable maintenance and service support which includes the
availability of spare parts for at least ten years.
Frico saves energy
Thanks to our broad product range and our many years of
experience, Frico is able to help you save energy. By offering
total solutions, including both complete heating systems and
products for additional heating, we can generate a comfortable
indoor climate at a low energy cost. Our regulation systems
for different levels ensure that you never use more energy
than is required. Through our parent company, Systemair,
we also possess knowledge about ventilation and can provide
appropriate solutions.
Climate-smart
At Frico, we are proud to be able to offer energy-efficient
products for a better indoor climate. In our product
development work, the focus is on achieving the greatest
possible function with the least possible energy consumption –
without compromising on our core values of trust, competence
and design.
This means that our products not only manage the local
climate in business complexes, industrial buildings, offices or
summer cottages; with optimum energy efficiency, we ensure
that our products are climate-smart.
Frico's headoffice is located outside Gothenburg in
Sweden and we are a part of the Systemair Group.
Today Frico is represented in 70 countries world
wide either by subsidiaries or distributors. Updated
information is always available on our website
www.frico.se.
We manufacture at production units in
Skinnskatteberg, Sweden and at other ISO-certified
production units in Europe. Our warehouses are
strategically placed in several places in Europe.
5
Air curtains - Thermozone®
Thermozone air curtains create an invisible barrier
at openings and doors which separates different
temperature zones without limiting access for people
and vehicles. With Thermozone Technology an efficient
air separation is created in combination with a low
sound level, giving comfortable climate and large
energy savings. Thermozone air curtains are appreciated
worldwide for their quality and operating efficiency, and
are currently used in over 50 countries.
Thermozone technology
Energy savings and good indoor climate
Scandinavian design
In many buildings, such as shops, warehouses, industrial premises
and goods terminals, doorways are open for a significant portion
of the day. Expensive heated or cooled air will be lost, especially
when the difference between the inside and outside temperatures
is substantial.
Thanks to Thermozone technology, performance
can be precisely adjusted to obtain an air curtain
with efficient separation that is also comfortable
to pass through.
R
Thermozone air curtains are optimized in:
•Airflowgeometry
•Performance
•Soundlevel
Frico cooperates with leading architects and product designers
to create today’s aesthetic products. The Thermozone range
has an elegant Scandinavian design and for visible mounting
there are models that harmonize with exclusive shop interiors
as well as industrial buildings. Recessed mounting is also
possible with only the outlet/inlet visible.
Low sound level and high performance
The Thermozone range has been developed and is manufactured
in our plant in Skinnskatteberg, Sweden. Here we have one of
the most sophisticated airflow and sound laboratories in Europe.
Advanced equipment and expertise make it possible to produce
air curtain products with the lowest sound level and the best
performance.
Air curtain knowledge
We at Frico know most of what there is to know about air
curtains and are happy to share that knowledge. We arrange
for example The Frico Academy, a training forum for our
distributors.Pleasesee"Thermozoneaircurtaincatalogue"for
further information, or contact us directly.
[oC]
[cm]
[cm]
Opening
Opening without aircurtain
[cm]
The heated or conditioned air escapes through this
unprotected opening. The result is energy loss and poor
comfort.
6
Opening
[cm]
Opening with correctly adjusted Thermozone®
A sharp separation between different temperature zones is
obtained with a correctly set up air curtain. Thermozone
creates a barrier that effectively prevents undesired air flows.
A i r cur t ai ns
Choose the right air curtain
For optimal air curtain effect, it is important to choose
the right air curtain. Thermozone air curtains are
available for doorways of any width and for heights up
to 8 metres. They blow from above, from the side or
from below. Choose between electrical, water heated or
unheated versions. To get the most out of the product,
the following hints are important to bear in mind.
•Theinstallationheightiscrucial.
•Theaircurtainunitsshouldcoverthewholewidth(or
height) of the opening. Thermozone can be obtained
indifferentlengths.Forwide(high)openings,several
unitsaremountedbeside(ontop)ofeachother.
•Theunitsshouldbepositionedasclosetotheopening
as possible.
•Foroptimalperformanceitisimportantthatthe
pressure difference between outside and inside is not
too big.
Control
For optimal comfort and energy saving the air curtain
needs to be controlled according to the requirements
and conditions at hand. A quick and precise control is
easily obtained. Our control kits on 3 different levels
for each product cover most needs. Read more about
the control kits in our air curtain catalogue or on
www.frico.se.
Thermozone® - overview
Type
Application
Installation
height/width
AD100
Small openings
Up to 1,5 m
ADA
Entrance/cold storage
Up to 2,5 m
AD200
Entrance/cold storage
Up to 2,5 m
AR200
Entrance
Up to 2,5 m
AR3500
Entrance
Up to 3,5 m
AR300
Entrance
Up to 3,5 m
Portier
Entrance
Up to 2,5 m
AC Corinte
Entrance
AD Corinte
El.
Water Ambient Mounting
heated heated unheated
Additional features
Page
Horizontal
Cable and plug.
AD105: only cable.
10
Horizontal
Cable and plug.
10
3
2
2
2
2
Up to 3 m
3
3
3
3
3
3
Entrance
Up to 3,5 m
3
2
SF
Entrance
Up to 4 m
RD
Entrance
Up to 3 m
AD300
Entrance/cold storage
2,5 m - 3,5 m
AD400
Industry/cold storage
3m-4m
PA3500
Entrance/cold storage
2,5 m - 3,5 m
PA4200
Industry/cold storage
3 m - 4,2 m
3
3
3
3
3
3
AG4500/5000
Industry/cold storage
Up to 5 m
2
2
2
2
2
2
2
AC500
Industry
3m-6m
UF600
Industry
Large doorways
AGI
Industry
Large doorways
ADA Cool
Cold storage
Up to 2,5 m
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
Horizontal
11
Horizontal
Recessed model.
12
Horizontal
Recessed model.
13
Horizontal
Recessed model.
14
Horizontal
Brushed stainless steel.
15
Horizontal/vertical
Brushed stainless steel as
standard.
16
Horizontal/vertical
Polished, mirror polished or
brushed stainless steel.
17
Vertical
For revolving doors.
18
Horizontal
For revolving doors.
19
Horizontal
20
Horizontal
21
Horizontal/vertical
Recessed mounting possible
Horizontal/vertical
Recessed mounting possible
22
23
Horizontal
24
Horizontal/vertical
25
Vertical
25
Horizontal/vertical
26
Horizontal
Special terminals for easy
connection of several units.
Cable and plug.
27
7
Air curtains - Thermozone®
Installation examples for air curtains
Thermozone air curtains are available for openings of different
sizes and for different application areas. To facilitate your
choice of product, you will find some typical cases on the
following pages. More detailed information on important factors
to consider when choosing an air curtain is found on the
previous pages.
Pleasenotethatitistheinstallationheightthatisdecisive
and not the height of the opening.
Basic criterias:
1. Type of premises: store, warehouse etc.
2. Height: installation height
3. Width: installation width
4. Mounting: horizontal or vertical
5.Connection:ambient,unheated(A),electrical(E),water(W)
Small openings
Kiosk or service hatch
1. Type of premises: Kiosk
2. Installation height: 1 m
3. Installation width: 0,8 m
4. Mounting: Horizontal
5. Connection: Electrical
1m
1m
Recommendation: An AD102/103 is recommended for these
conditions. For the 1,5 metre opening, two units are mounted
side by side to cover the whole width.
0,8 m
1,5 m
Shop
1. Type of premises: Shop
2. Installation height: 2,1 m
3. Installation width: 1 m
4. Mounting: Horizontal
5. Connection: Electrical
2,1 m
2,2 m
Recommendation: An AD210E06 or AD210E09 is
recommended for these conditions.
2. Installation height: 2,2 m
3. Installation width: 2 m
2m
1m
Recommendation: A shop with a large entrance and a lot of
traffic through the opening requires a larger unit to obtain
a comfortable climate. For these conditions we recommend
AD320E18.
Bank
1. Type of premises: Bank
2. Installation height: 2,2 m
3. Installation width: 2 m
4. Mounting: Horizontal or vertical
5. Connection: Water
2,2 m
2m
Entrance
Recommendation: For an opening with high demands on
design and performance we recommend one or two AD Corinte
depending on the premises. AD Corinte can be installed
horizontally or vertically.
8
2,2 m
2m
A i r cur t ai ns
Air curtains - Thermozone®
Goods reception, grocery store
1. Type of premises: Goods reception, grocery store
2. Installation height: 3 m
3. Installation width: 3 m
4. Mounting: Horizontal
5. Connection: Water
3m
Recommendation:TwoPA3515WLarerecommendedfor
these conditions.
3m
Warehouse
1. Type of premises: Warehouse
2. Installation height: 4 m
3. Installation width: 4 m
4. Mounting: Vertical
5. Connection: Water
4m
Recommendation: Four vertically mounted
PA4220WLbesidetheopening,twoateachsideare
recommended for these conditions.
4m
Factory, heavy industry
6m
Recommendation: For these conditions we recommend
UF600. Air is pressed out at high speed through a narrow
slot in the floor inside the opening. UF600 provides nearly
100 % protection against cold draughts along the floor.
4m
Industry
1. Type of premises: Factory, heavy industry
2. Installation height: 6 m
3. Installation width: 4 m
4. Mounting: Vertical
5. Connection: Ambient
Cold room
Recommendation: Two ADA Cool are recommended for
these conditions, mounted side by side above the opening.
2,5 m
2,5 m
Cold storage
1. Type of premises: Cold room
2. Installation height: 2,5 m
3. Installation width: 2,5 m
4. Mounting: Horizontal
5. Connection: Ambient
9
Thermozone® ADA
Designed primarily for smaller openings
such as kiosk and service hatches.
The airflow can be regulated in two steps.
Resetable overheat protection.
Built-in thermostat (5-35 °C).
Models AD102 and AD103 are equipped
with cable and plug, AD105 only cable.
Height: 217 mm
Depth: 131 mm
Colour: white, RAL 9016.
CE compliant.
Designed to prevent loss of conditioned air.
Installation height up to 2,5 metres.
Suitable where space is limited between the
ceiling and the upper edge of the doorway.
Without heat.
With cable and plug.
Built-in switch for high/low speed.
Height: 235 mm
Depth: 215 mm
Colour: white, RAL 9016.
CE compliant.
1,5 m
Thermozone® AD100
0,8 m
Thermozone AD100, electrically heated (IP20)
10
Type
Voltage
AD102
AD103
AD105
[V]
230V~
230V~
230V~
Heat
output
[kW]
0/1/2
0/1,5/3
0/3/4,5
Airflow
[m³/h]
400
400
500
Thermozone ADA, ambient, unheated (IP21)
3
Sound
level
[dB(A)]
36/48
36/48
50
Conditions for sound level measurements, see page 67.
Length
[mm]
806
806
806
Type
Voltage
ADA090H
ADA120H
ADA090L
ADA120L
[V]
230V~
230V~
230 V~
230 V~
Heat
output
[kW]
0
0
0
0
Airflow
[m³/h]
1150
1400
820
1350
2,5 m
Air curtains - Thermozone® Small openings and Entrance
0,9 / 1,2 m
1
Sound
level
[dB(A)]
43/54
44/51
43/54
48/55
Length
[mm]
900
1200
900
1200
A i r cur t ai ns
Air curtains - Thermozone® Entrance
Thermozone® AD200A/E/W
Installation height up to 2,5 metres.
Recessed mounting possible.
Height: 225 mm
Depth: 350 mm
Colour: white, RAL 9016.
Approved by SEMKO and CE compliant.
Thermozone AD200W, water heated (IP21)
Type
2,5 m
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AD210W
230V~
7
1200
38/49
1020
AD215W
230V~
12
1800
40/51
1530
AD220W
230V~
15
2400
41/52
1960
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
1 / 1,5 / 2 m
Thermozone AD200A, ambient, unheated (IP21)
Type
Voltage
AD210A
AD215A
AD220A
[V]
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
Airflow
[m³/h]
1400
2100
2800
1
Sound
level
[dB(A)]
41/51
43/53
44/54
Length
[mm]
1020
1530
1960
Thermozone AD200C, electrically heated, built-in thermostat
and control box, cable and plug (IP21) 3
Voltage
AD210C03
AD210C05
[V]
230V~
230V~
Heat
output
[kW]
0/2/3
0/2,3/4,5
Airflow
[m³/h]
1400
1400
Sound
level
[dB(A)]
41/47
41/47
Thermozone AD200E, electrically heated (IP21)
Type
Voltage
AD210E03
AD210E06
AD210E09
AD215E05
AD215E09
AD215E14
AD220E12
AD220E18
[V]
230V~
400V3N~
400V3N~
400V3N~
400V3N~
400V3N~
400V3N~
400V3N~
Heat
output
[kW]
0/1,5/3
0/3/6
0/4,5/9
0/2,3/4,5
0/4,5/9
0/6,7/13,5
0/6/12
0/9/18
Airflow
[m³/h]
1400
1400
1400
2100
2100
2100
2800
2800
Length
[mm]
1020
1020
3
Sound
level
[dB(A)]
41/51
41/51
41/51
43/53
43/53
43/53
44/54
44/54
Length
[mm]
1020
1020
1020
1530
1530
1530
1960
1960
Control kits AD200E 3
CK01E
CB32N, controls the airflow in 3 steps and the heat
Level 1
output in 2 steps
RTI2, 2-step room thermostat
CK02E
Level 2
CB32N, RTI2 and
MDC, magnetic door contact with time relay
CK03
Level 3
ADEA, air curtain control with outdoor sensor,
built-in room sensor and door contact
ADEAIS, external room sensor
ADEAEB, external control board
Conditions for sound level measurements, see page 67.
Control kits AD200W 2
CK01W
CB30N, controls the airflow in 3 steps
Level 1
T10, room thermostat
CK02W
Level 2
CB30N and RTI2, 2-step room thermostat
MDC, magnetic door contact with time relay
CK03
Level 3
ADEA, air curtain control with outdoor sensor,
built-in room sensor and door contact
ADEAIS, external room sensor
ADEAEB, external control board
Note! A valve set VR20/25 (option: TVV20/25 with SD20) should
be added for a complete control kit.
Control kit AD200A 1
Level 1
CB30N, controls the airflow in 3 steps
Type
2
Voltage
Accessories - AD200A/E/W
Type
Description
CK01E
Control kit Electric level 1 (CB32N, RTI2)
CK02E
Control kit Electric level 2 (CB32N, RTI2, MDC)
CK03
Control kit level 3 (ADEA, ADEAIS, ADEAEB)
CK01W
Control kit Water level 1 (CB30N, T10)
CK02W
Control kit Water level 2 (CB30N, RTI2, MDC)
CB30N
Control box (A/W)
CB32N
Control box (E)
ADSR54
Stepless fan speed control, IP54
ADEA
Air curtain control
ADEAEB
External control board, IP55
ADEAIS
External room sensor, IP30
ADEAGD1
Additional control board to acheive BMS functionality
KRT2800
2-step room thermostat, IP55
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
T10
Room thermostat, IP30
KRT1900
Room thermostat, IP55
MDC
Magnetic door contact with time relay, IP44
KUR
Digital time switch, IP55
CBT
Electronic timer, IP44
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
22003
False ceiling grille 1192 mm
22004
False ceiling grille 1515 mm
ADPK1
Suspension kit, max 1 m
ADPF1
Suspension brackets (pair)
More information about accessories on pages 30-31 and 62-66.
11
Air curtains - Thermozone® Entrance
Thermozone® AR200A/E/W
2,5 m
AR200 is especially suited for
environments with high demands in
respect of design. It is recessed in ceilings
above entry doors and other small doors
where the height is no greater than
2.5 metres. A low unit height makes it
possible to install AR200 where ceiling
space is limited. The recessed installation
and low sound level makes AR200 very
discreet.
1 / 1,5 / 2 m
The visible bottom plate may be
painted to make it blend even better with
the premises.
Just one model per length with a choice of outputs and
voltages selectable on installation making it simple and flexible
to adapt the output to current need.
Installation height up to 2.5 metres.
Height: 198 mm
Depht: 432 mm
Colour (bottom plate): white, RAL 9016
CE compliant.
Thermozone AR200A, ambient, unheated (IP20)
Type
Voltage
Output
Airflow
AR210A
AR215A
AR220A
[V]
230V~
230V~
230V~
[kW]
0
0
0
[m³/h]
1200
1750
2400
1
Sound
level
[db(A)]
34/50
34/50
40/54
Length
[mm]
1042
1552
2042
Control kits AR200A 1
Level 1
CB30N, controls the airflow in 3 steps
Thermozone AR200E, electrically heated (IP20) 3
Type
Output
Output
Airflow
Sound
Length
steps
steps
level
400V3N~ 230V~
[kW]
[kW]
[m³/h]
[db(A)]
[mm]
0/3
0/6/9
AR210E09
1200
34/50
1042
0/3
0/3/5
0/4,5
0/6,8/11,3 AR215E11
1750
34/50
1552
0/4,5
0/4,5/6,8
0/6
0/12/18
AR220E18
2400
40/54
2042
0/6
0/6/10
AR200E is delivered as 9 kW, 11 kW and 18 kW (400 V3N~) models, but
they are convertible to 230 V~ and different outputs as shown in above
table.
Control kits AR200E 3
CK01E
CB32N, controls the airflow in 3 steps and the heat
Level 1
output in 2 steps
RTI2, 2-step room thermostat
CK02E
Level 2
12
CB32N, RTI2 and
MDC, magnetic door contact with time relay
Conditions for sound level measurements, see page 67.
Thermozone AR200W, water heated (IP20)
Type
Voltage
Output
2
Airflow
Sound
Length
level
[V]
[kW]
[m³/h]
[db(A)]
[mm]
AR210W
230V~
7
1000
41/49
1042
230V~
11
AR215W
1600
37/50
1552
AR220W
230V~
14
2000
44/53
2042
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
Control kits AR200W 2
CK01W
CB30N, controls the airflow in 3 steps
Level 1
T10, room thermostat
CK02W
Level 2
CB30N and RTI2, 2-step room thermostat
MDC, magnetic door contact with time relay
Note! A valve set VR20/25 (option: TVV20/25 with SD20) should
be added for a complete control kit.
Accessories - AR200
Type
Description
CK01E
Control kit Electric level 1 (CB32N, RTI2)
CK02E
Control kit Electric level 2 (CB32N, RTI2, MDC)
CK01W
Control kit Water level 1 (CB30N, T10)
CK02W
Control kit Water level 2 (CB30N, RTI2, MDC)
CB32N
Control box (E)
CB30N
Control box (A/W)
T10
Electronic thermostat, IP44
KRT2800 2-step room thermostat, IP55
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
MDC
Magnetic door contact with time relay, IP44
MDCDC
Magnetic door contact
CBT
Electronic timer, IP44
KUR
Digital time switch, IP55
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
More information about accessories on pages 30-31 and 62-66.
A i r cur t ai ns
Air curtains - Thermozone® Entrance
Thermozone® AR3500E/W
Accessories - AR3500E/W
Type
3,5 m
AR3500 is especially suited for
environments with high demands in
respect of design. The recessed installation
is very discreet and the built-in control
contributes further to the concealed
appearance.
Installation height up to 3,5 metres.
Easy to service via a large hatch in the
bottom of the unit. The filter is cleaned
from the outside.
Height: 302 mm
Depth: 595 mm
Colour (frame and hatch): white, RAL9016.
Other colours as option. Approved by
SEMKO and CE compliant.
1 / 1,5 / 2 m
Thermozone AR3500E, electrically heated (IP44)*
Type
Voltage
AR3510E09
AR3515E14
AR3520E18
[V]
400V3~
400V3~
400V3~
Heat
output
[kW]
0/4,5/9
0/7/13,5
0/9/18
Airflow
[m³/h]
2000
2800
4000
Thermozone AR3500W, water heated (IP44)*
Type
3
Sound
level
[dB(A)]
43/59
43/60
46/63
Length
[mm]
1057
1567
2073
2
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AR3510W
230V~
16
2000
43/58
1057
AR3515W
230V~
23
2800
43/59
1567
AR3520W
230V~
33
4000
46/62
2073
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
*) Protection class AR3500E/W recessed mounting: above false
ceiling – splash-proof design (IP44), below false ceiling: normal
design (IP20).
Control options
This air curtain is supplied with an intregrated PC board SIRe.
SIRe is an intelligent and well designed low voltage control
system which can be customised for each unique application
and environment. SIRe is supplied pre-programmed with quick
fit plug connections and is very easy to use and install. If more
than one air curtain should be controlled by a single SIRe, an
additional modular cable SIReCC per unit is needed. Cables
between units can easily be joined together by using joint
piece SIReCJ. There are three different levels with different
functionality to choose from, Basic, Competent or Advanced.
Description
Control system SIRe Basic
Control system SIRe Competent
Control system SIRe Advanced
External room temperature sensor
Kit for recessed installation
Clamp-on sensor
Used to join two RJ11(4/4)
Used to join two RJ12 (6/6)
Modular cable RJ12 3 m
Modular cable RJ12 5 m
SIReCC610 Modular cable RJ12 10 m
SIReCC615 Modular cable RJ12 15 m
SIReCC403 Modular cable RJ11 3 m
SIReCC405 Modular cable RJ11 5 m
SIReCC410 Modular cable RJ11 10 m
SIReCC415 Modular cable RJ11 15 m
VOS15LF
Valve kit on/off, low flow, DN15, Kvs 0,90
VOS15NF
Valve kit on/off, DN15, Kvs 1,8
VOS20
Valve kit on/off, DN20, Kvs 3,4
VOS25
Valve kit on/off, DN25, Kvs 7,2
VOSP15LF Pressure independent valve kit, low flow, DN15
VOSP15NF Pressure independent valve kit, DN15
VOSP20
Pressure independent valve kit, DN20
VOSP25
Pressure independent valve kit, DN25
VOT15
3-way control valve and actuator on/off, DN15, Kvs 1,7
VOT20
3-way control valve and actuator on/off, DN20, Kvs 2,5
VOT25
3-way control valve and actuator on/off, DN25, Kvs 4,5
VMO15LF
Modulating valve kit, low flow, DN15, Kvs 0,40
VMO15NF Modulating valve kit, DN15, Kvs 1,0
VMO20
Modulating valve kit, DN20, Kvs 2,0
VMO25
Modulating valve kit, DN25, Kvs 4,0
VMOP15LF Pressure independent modulating valve kit, low flow, DN15
VMOP15NF Pressure independent and modulating valve kit, DN15
VMOP20
Pressure independent and modulating valve kit, DN20
VMOP25
Pressure independent and modulating valve kit, DN25
VMT15
3-way control valve and modulating actuator, DN15, Kvs 1,7
VMT20
3-way control valve and modulating actuator, DN20, Kvs 2,5
VMT25
3-way control valve and modulating actuator, DN25, Kvs 4,5
VAT
Adjustment tool
AR35XTT10 Extension for AR3510
SIReB
SIReAC
SIReAA
SIReRTX
SIReUR
SIReWTA
SIReCJ4
SIReCJ6
SIReCC603
SIReCC605
AR35XTT15 Extension for AR3515
AR35XTT20 Extension for AR3520
More information about accessories on pages 28-29 and 66.
Product specific accessories, AR3500
Water control
Valve kit VOS(P), VOT, VMO(P) or VMT is used to control the
water flow, see final section of this catalogue.
AR35XTT, extension
Outlet/inlet extension for a discreet installation with only the
outlet and inlet visible in the ceiling.
13
Air curtains - Thermozone® Entrance
Thermozone® AR300E/W
Control
3,5 m
AR300 is especially suited for environments
with high demands in respect of design. The
recessed installation is very discreet and the
built-in control contributes further to the
concealed appearance.
Installation height up to 3,5 metres.
Easy to service via a large hatch in the
bottom of the unit. The filter is cleaned from
the outside.
Height: 302 mm
Depth: 595 mm
Colour (frame and hatch): white, RAL9016
Approved by SEMKO and CE compliant.
1 / 1,5 / 2 m
Thermozone AR300E, electrically heated (IP44)
Type
Voltage
AR310E09
AR315E14
AR320E18
[V]
400V3~
400V3~
400V3~
Heat
output
[kW]
0/4,5/9
0/7/13,5
0/9/18
Airflow
[m³/h]
2000
2800
4000
Thermozone AR300W, water heated (IP44)
Type
Accessories - AR300
3
Sound
level
[dB(A)]
43/59
43/60
46/63
The built-in control of AR300 is designed to give the highest
level of functionality while minimizing installation and daily
operation. No additional wiring or external controls are
needed. If the distance between the eye and the reflector is
too long, it is possible to use an external door contact instead
(accessory).
The air curtain operates at its maximum performance in all
situations and is not dependent on day-to-day adjustments.
When the door is open the air curtain separates outdoor and
indoor air and provides heat if it is needed.
When the door is closed the air curtain operates as part
of the heating system supplying additional heat if indoor
temperature falls below desired temperature. There are also
possibilities to connect the air curtain to a BMS system for on/
off control and alarm indication.
Length
[mm]
1057
1567
2073
2
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AR310W
230V~
16
2000
43/58
1057
AR315W
230V~
23
2800
43/59
1567
AR320W
230V~
33
4000
46/62
2073
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
Type
Description
AR300DS
External door contact, with 7 m cable
AR300ERS External room sensor, with 7 m cable
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
More information about accessories on page 66.
Recommended set of valves
Type
AR310W
AR315W
AR320W
Water temperature
VR20
60/40
80/60
60/40
80/60
60/40
80/60
X
X
X
Product specific accessories, AR300
The thermostat setting
and open door fan speed
selection is hidden under
the cover.
The IR-eye detects when the
door is open and closed. The
thermostat is located by the
air intake and heat or ambient
mode is set by a push button.
Alarm indication by LED.
14
Conditions for sound level measurements, see page 67.
VR25
AR300DS, external door contact
When the distance between the eye and the reflector
is too long an external door contact AR300DS is
needed. The external door contact is supplied with
7 m cable and a modular contact for easy and quick
installation (no other adjustments are needed to get
the accessories working). The connection of the door
contact is done on the control box accessible by
opening the service hatch of the AR300.
AR300ERS, external room sensor
If an external room sensor is needed, use the
AR300ERS. The external room sensor is supplied
with 7 m cable and a modular contact for easy and
quick installation (no other adjustments are needed
to get the accessories working). The connection
of the room sensor is done on the control box
accessible by opening the service hatch of the
AR300.
X
X
X
A i r cur t ai ns
Air curtains - Thermozone® Entrance
Thermozone® Portier 200 A/E
For exclusive entrances.
Installation height up to 2,5 metres.
Mounting brackets available as an accessory.
Overheat protection.
Height: 280 mm
Depth: 295 mm
Colour: brushed stainless steel.
CE compliant.
2,5 m
P2WB
1
1 / 1,5 m
Thermozone Portier 200A, ambient, unheated (IP21)
Type
Voltage
PS210A
PS215A
[V]
230V~
230V~
Heat
output
[kW]
0
0
Airflow
[m³/h]
1300
2000
1
Sound
level
[dB(A)]
44/54
46/56
Length
P2JK
[mm]
1020
1530
2
Control kits Portier 200A 1
Level 1
CB20, controls the airflow in 2 steps
3
Thermozone Portier 200E, electrically heated (IP21)
Type
3
Voltage
Heat
Airflow Sound
Length
output
level
[V]
[kW]
[m³/h] [dB(A)]
[mm]
PS210E03 230V~/400V3N~* 0/1,5/3
1200
44/50
1020
PS210E06 400V3N~*
0/3/6
1200
44/50
1020
PS210E09 400V3N~*
0/4,5/9
1200
44/50
1020
PS215E09 400V3N~*
0/4,5/9
1900
39/50
1530
PS215E14 400V3 + 230V~
0/6,7/13,5 1900
39/50
1530
*) Alternative 400 V3~ + 230 V~ (operating supply) if the current is
greater than 16 A. Applies when connecting several units.
Control kits Portier 200E 3
Level 1
CB22, controls the airflow in 2 steps and the heat
output in 2 steps
RTI2, 2-step room thermostat
Level 2
CB22, RTI2 and
MDC, magnetic door contact with time relay
Level 3
ADEA, air curtain control with outdoor sensor,
built-in room sensor and door contact
ADEAEB, external control board
Accessories - Portier 200A/E
Type
Description
CB20
Control box (A)
CB22
Control box (E)
ADSR54
Stepless fan speed control, IP54
ADEA
Air curtain control
ADEAEB
External control board, IP55
ADEAIS
External room sensor, IP30
ADEAGD1 Additional control board to acheive BMS functionality
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
MDC
Magnetic door contact with time relay, IP44
ADPK1
Suspension kit, max 1 m
ADPF1
Suspension brackets (pair)
P2WB
Wall mounting kit
P2JK
Joining kit 2x1 m
More information about accessories on pages 30-31 and 62-63.
15
Thermozone® AC Corinte E/W
For exclusive entrances with high demands on
design, noise level and finish.
Slim design in stainless steel.
Mounted with one unit on either side of the
opening, thus creating a classic symmetry.
Can also be mounted horizontally.
Installation width up to 5 metres (2 units).
Installation height up to 3 metres.
Height/depth: 393 mm
Depth/width: 314 mm
Colour: brushed stainless steel (option: polished
or mirror polished stainless steel)
CE compliant.
Ordering key: see AD Corinte
Thermozone AC Corinte E, electrically heated (IP20)
Type
5m
Type
2
Voltage
Airflow
Heat
Sound
Height/
output*2
level
Length
[kW]
[V]
[m³/h]
[dB(A)]
[mm]
230V~
19
1900
44/61
1500
ACC10WL*1
ACC15WL*1
230V~
29
2600
45/62
1500
ACC20WL
230V~
42
3800
47/64
2000
ACC25WL
230V~
52
4500
48/65
2500
ACC30WL
230V~
60
5100
48/65
3000
*1) ACC10WL and ACC15WL are available only for horizontal mounting
*2) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC
3
Voltage
Control kits ACC E 3
CK01E
CB32N, controls the airflow in 3 steps and the heat
Level 1
output in 2 steps
RTI2, 2-step room thermostat
CK02E
Level 2
CB32N, RTI2 and
MDC, magnetic door contact with time relay
CK03GD
Level 3
ADEA, air curtain control with outdoor sensor,
built-in room sensor and door contact
ADEAIS, external room sensor
ADEAEB, external control board
ADEAGD1, extra control board
Conditions for sound level measurements, see page 67.
1,0 / 1,5 / 2,0 / 2,5 / 3,0 m
Thermozone AC Corinte WL, water heated (IP20)
Heat
Airflow
Sound
Height/
output
level
Length
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
1900
44/61
1000
ACC10E*1 230V~/400V3~ 0/6/9
ACC15E*1 230V~/400V3~ 0/8/12
2600
45/62
1500
ACC20E
230V~/400V3~ 0/12/18
3800
47/64
2000
ACC25E
230V~/400V3~ 0/12/18
4500
48/65
2500
ACC30E*2 230V~/400V3~ 0/20/30
5100
48/65
3000
*1) ACC10E and ACC15E are available only for horizontal mounting
2
* ) ACC30E is available in special design with output steps 0/12/18 kW.
16
3m
2,0 / 2,5 / 3,0 m
Air curtains - Thermozone® Entrance
Control kit s ACC W 2
CK01W
CB30N, controls the airflow in 3 steps
Level 1
T10, room thermostat
CK02W
Level 2
CB30N and RTI2, 2-step room thermostat
MDC, magnetic door contact with time relay
CK03GD
Level 3
ADEA, air curtain control with outdoor sensor,
built-in room sensor and door contact
ADEAIS, external room sensor
ADEAEB, external control board
ADEAGD1, extra control board
Note! A valve set VR20/25 (option: TVV20/25 with SD20) should
be added for a complete control kit.
Accessories - AC Corinte E/W
Type
Description
Control kit Electric level 1 (CB32N, RTI2)
Control kit Electric level 2 (CB32N, RTI2, MDC)
Control kit level 3 (ADEA, ADEAIS, ADEAEB, ADEAGD1)
Control kit Water level 1 (CB30N, T10)
Control kit Water level 2 (CB30N, RTI2, MDC)
Control box (A/W)
Control box (E)
Air curtain control
External control board, IP55
External room sensor, IP30
Additional control board to acheive ADEA and BMS
functionality
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat, knob, IP44
T10
Room thermostat, IP30
KRT1900
Room thermostat, IP55
MDC
Magnetic door contact with time relay, IP44
AGB304
Door contact, IP44
KUR
Digital time switch, IP55
CBT
Electronic timer, IP44
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
ACCWBP
Wall bracket polished bright annealed*
ACCWBB
Wall bracket brushed stainless steel*
ACCWBMP Wall bracket mirror polished stainless steel*
AXP300
Collision protection
*) For ACC 1-1,5 m: order 2 pcs, for ACC 2-3 m: order 3 pcs.
More information about accessories on pages 30-31 and 62-66.
.
CK01E
CK02E
CK03GD
CK01W
CK02W
CB30N
CB32N
ADEA
ADEAEB
ADEAIS
ADEAGD1
For exclusive entrances with high demands on
design, noise level and finish.
Mounted with one unit on either side of the
opening, thus creating a classic symmetry.
Can also be mounted horizontally.
Installation width up to 5 metres (2 units).
Installation height up to 3,5 metres.
Height/depth: 500 mm
Depth/width: 350 mm
Colour: polished, mirror polished or brushed
stainless steel. Colour intake and outlet grille:
black, RAL 9005.
CE compliant.
ADCS17A*¹
ADCS22A
ADCS25A*²
[V]
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
Control options
This air curtain is supplied with an intregrated PC board SIRe.
SIRe is an intelligent and well designed low voltage control
system which can be customised for each unique application
and environment. SIRe is supplied pre-programmed with quick
fit plug connections and is very easy to use and install. If more
than one air curtain should be controlled by a single SIRe, an
additional modular cable SIReCC per unit is needed. Cables
between units can easily be joined together by using joint
piece SIReCJ. There are three different levels with different
functionality to choose from, Basic, Competent or Advanced.
Airflow
Voltage
[m³/h]
3000
4000
4500
ADCS17E*¹
ADCS22E
ADCS25E*²
[V]
230V~/400V3~
230V~/400V3~
230V~/400V3~
Heat
output
[kW]
0/7,5/15
0/10/20
0/11,2/22,5
1
Sound
level
[dB(A)]
40/60
42/61
43/63
Thermozone AD Corinte E, electrically heated (IP20)
Type
1,7 / 2,2 m
5m
Thermozone AD Corinte A, ambient, unheated (IP20)
Voltage
3,5 m
2,2 / 2,5 m
Thermozone® AD Corinte A/E/W
Type
A i r cur t ai ns
Air curtains - Thermozone® Entrance
Airflow
3
Sound
level
[dB(A)]
40/60
42/61
43/63
[m³/h]
3000
4000
4500
Height/
Length
[mm]
1700
2200
2450
Height/
Length
[mm]
1700
2200
2450
Water control
Valve kit VOS(P), VOT, VMO(P) or VMT is used to control the
water flow, see final section of this catalogue.
Accessories - AD Corinte A/E/W
Type
Description
SIReB
SIReAC
SIReAA
ADCMP
ADCMS
ADCEH
AXP300
Control system SIRe Basic
Control system SIRe Competent
Control system SIRe Advanced
Joining kit for suspended installation
Joining kit for wall installation
Extension hood AD Corinte
Collision protection
See AR3500 for accessories for SIRe and valve kits.
Thermozone AD Corinte W, water heated (IP20)
Type
2
Voltage
Airflow Sound Height/
Heat
output*3
level
Length
[kW]
[V]
[m³/h]
[dB(A)] [mm]
ADCS17WL*¹ 230V~
33
3000
39/59
1700
ADCS22WL
230V~
46
4000
42/60
2200
ADCS25WL*² 230V~
52
4500
42/61
2450
*¹) ADCS17 is available only for horizontal mounting.
*²) ADCS25 is available only for vertical mounting.
*3) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
Ordering key AC Corinte and AD Corinte
Type - Unit shape - Connections position - Finish / Material
Example: ADCS20WL - VL - A - P
Type
See technical specifications
Unit shape
HL (Horizontal, connections to the left),
HR (Horizontal, connections to the right)
VL (Vertical Left) or VR (Vertical Right)
seen from the inside
Connections position
A or B, see below.
Finish / material
P = Polished bright annealed
B = Brushed stainless steel
MP = Mirror polished stainless steel
Product specific accessories, AD Corinte
ADCEH, extension hood
Extension hood used to cover the space between
the ceiling and the air curtain for a neat finish.
Connections position
ADCM P/S, joining kit for horizontal mounting
Joining kit that is used when several AD Corinte
are put together to give a neater and more unified
installation. ADCMP for suspended installation and
ADCMS for wall installation.
HL
Conditions for sound level measurements, see page 67.
A
A
B
B
HR
17
Air curtains - Thermozone® Entrance
4m
Thermozone® SF
For circular and revolving doors with
openings up to 4 metres wide.
Mounted vertically beside the opening.
Curved design that integrates neatly with the
door.
Extension possible up to 3900 mm (extension
without fans). Units higher than 3000 mm are
delivered in two pieces.
Several optional finishes are available.
Depth: 270 mm
Width: 560 mm
CE compliant.
Thermozone SF E, electrically heated (IP20)
Type
Voltage
SF18E09
SF24E12
SF36E18
SF54E30
[V]
400V3~
400V3~
400V3~
400V3~
Heat
output
[kW]
0/6/9
0/8/12
0/12/18
0/20/30
Airflow
[m³/h]
1800
2400
3600
5400
Thermozone SF W, water heated (IP20)
Type
Heat
Airflow
Sound
Height
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
SF18WL
230V~
18
1800
55
2200
SF24WL
230V~
23
2400
56
2200
SF36WL
230V~
38
3600
57
2200
SF54WL
230V~
49
5400
57
2200
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
Control kit SF W 2
CK02W
CB30N, controls the airflow in 3 steps
Level 2
RTI2, 2-step room thermostat
MDC, magnetic door contact with time relay
3
Sound
level
[dB(A)]
55
56
57
57
2
Voltage
Height
[mm]
2200
2200
2200
2200
Control kit SF E 3
CK02E
CB32N, controls the airflow in 3 steps and the heat
Level 2
output in 2 steps
RTI2, 2-step room thermostat
MDC, magnetic door contact with time relay
Note! A three-way motor valve with actuator and by-pass valve
VKSF (option: VR20/25 or only TVV20/25 with SD20) should be
added for a complete control kit.
Accessories - SF E/W
Type
Description
CK02E
Control kit Electric level 2 (CB32N, RTI2, MDC)
CK02W
Control kit Water level 2 (CB30N, RTI2, MDC)
CB30N
Control box (W)
CB32N
Control box (E)
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
T10
Room thermostat, IP30
KRT1900
Room thermostat, IP55
MDC
Magnetic door contact with time relay, IP44
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
VKSF
Built-in valve set for SF
FH25
Flexible hose DN25, L=1 m, 2 pcs
More information about accessories on pages 30-31 and 62-66.
Finish / Material selection
18
Powder coating RAL
State RAL code
Powder coating NCS
State NCS code
Stainless steel, brushed grain 240
State B240
Stainless steel, polished bright annealed
State P
Stainless steel, mirror polished
State M (not standard)
Conditions for sound level measurements, see page 67.
A i r cur t ai ns
Air curtains - Thermozone® Entrance
Thermozone® RD
For circular and revolving doors of all
sizes with opening height up to 3 metres.
Discreet mounting on top of the revolving
door with only the outlet grille visible.
The outlet is adapted to fit the revolving
door.
Several optional finishes are available.
Height: 250 mm
Depth: 520 mm
CE compliant.
Thermozone RD E, electrically heated (IP20)
Type
Voltage
RD18E09
RD27E15
RD36E23
RD54E30
RD63E36
[V]
400V3~
400V3~
400V3~
400V3~
400V3~
Heat
output
[kW]
0/6/9
0/10/15
0/15/22,5
0/20/30
0/24/36
Airflow
[m³/h]
1800
2700
3600
5400
6300
Thermozone RD W, water heated (IP20)
Type
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
RD18WL
230V~
16
1800
48
1000
RD27WL
230V~
19
2400
49
1000
RD36WL
230V~
29
3500
50
1500
RD54WL
230V~
42
5100
51
2000
RD63WL
230V~
51
6000
52
2500
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
3m
Control kit RD W 2
CK02W
CB30N, controls the airflow in 3 steps
Level 2
RTI2, 2-step room thermostat
MDC, magnetic door contact with time relay
3
Sound
level
[dB(A)]
48
49
50
51
52
2
Voltage
Length
[mm]
1000
1000
1500
2000
2500
Control kit RD E 3
CK02E
CB32N, controls the airflow in 3 steps and the heat
Level 2
output in 2 steps
RTI2, 2-step room thermostat
MDC, magnetic door contact with time relay
Note! A three-way motor valve with actuator and by-pass valve
VKRD (option: VR20/25 or only TVV20/25 with SD20) should be
added for a complete control kit.
Accessories - RD E/W
Type
Description
CK02E
Control kit Electric level 2 (CB32N, RTI2, MDC)
CK02W
Control kit Water level 2 (CB30N, RTI2, MDC)
CB30N
Control box (W)
CB32N
Control box (E)
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
T10
Room thermostat, IP30
MDC
Magnetic door contact with time relay, IP44
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
VKRD
Built-in valve set for RD
AFTRD
Built-in antigel thermostat for RD
FH25
Flexible hose DN25, L=1 m, 2 pcs
More information about accessories on pages 30-31 and 62-66.
Finish / Material selection
Powder coating RAL
State RAL code
Powder coating NCS
State NCS code
Stainless steel, brushed grain 240
State B240
Stainless steel, polished bright annealed
State P
Stainless steel, mirror polished
State M (not standard)
Conditions for sound level measurements, see page 67.
19
Air curtains - Thermozone® Entrance
Thermozone® AD300A/E/W
Thermozone AD300W, water heated (IP20)
Installation height 2,5-3,5 metres.
Combines high performance with a
compact size and an elegant design.
Recessed mounting possible.
Height: 340 mm
Depth: 490 mm
Colour: white, RAL 9016.
Approved by SEMKO and CE compliant.
Type
2,5 - 3,5 m
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AD310W
230V~
22
1800
44/57
1025
AD315W
230V~
37
3000
46/59
1565
AD320W
230V~
46
3600
47/60
2028
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
1 / 1,5 / 2 m
Thermozone AD300A, ambient, unheated (IP20)
Type
Voltage
AD310A
AD315A
AD320A
[V]
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
Airflow
[m³/h]
1900
3200
3800
1
Sound
level
[dB(A)]
46/57
47/60
50/61
Length
[mm]
1025
1565
2028
CB30N and MDC, magnetic door contact with time
relay
Thermozone AD300E, electrically heated (IP20)
Type
Voltage
AD310E09
AD315E14
AD320E18
[V]
400V3~
400V3~
400V3~
Heat
output
[kW]
0/4,5/9
0/7/13,5
0/9/18
Airflow
[m³/h]
1900
3200
3800
Length
[mm]
1025
1565
2028
Control kits AD300E 3
CK01E
CB32N, controls the airflow in 3 steps and the heat
Level 1
output in 2 steps
RTI2, 2-step room thermostat
CK02E
Level 2
CB32N, RTI2 and
MDC, magnetic door contact with time relay
CK03
Level 3
ADEA, air curtain control with outdoor sensor,
built-in room sensor and door contact
ADEAIS, external room sensor
ADEAEB*, external control board
*) ADEAEB can be replaced by internal control board ADEAIB, all items
must then be ordered separately and not as a kit.
20
Conditions for sound level measurements, see page 67.
CK02W
Level 2
CB30N and RTI2, 2-step room thermostat
MDC, magnetic door contact with time relay
CK03
Level 3
ADEA, air curtain control with outdoor sensor,
built-in room sensor and door contact
ADEAIS, external room sensor
ADEAEB*, external control board
Note! A valve set VR20/25 (option: TVV20/25 with SD20) should
be added for a complete control kit.
Accessories - AD300A/E/W
3
Sound
level
[dB(A)]
46/57
47/60
50/61
Control kits AD300W 2
CK01W
CB30N, controls the airflow in 3 steps
Level 1
T10, room thermostat
*) ADEAEB can be replaced by internal control board ADEAIB, all items
must then be ordered separately and not as a kit.
Control kits AD300A 1
Level 1
CB30N, controls the airflow in 3 steps
Level 2
2
Voltage
Type
Description
CK01E
Control kit Electric level 1 (CB32N, RTI2)
CK02E
Control kit Electric level 2 (CB32N, RTI2, MDC)
CK03
Control kit level 3 (ADEA, ADEAIS, ADEAEB)
CK01W
Control kit Water level 1 (CB30N, T10)
CK02W
Control kit Water level 2 (CB30N, RTI2, MDC)
CB30N
Control box (A/W)
CB32N
Control box (E)
ADSR54
Stepless fan speed control, IP54
ADEA
Air curtain control
ADEAEB
External control board, IP55
ADEAIS
External room sensor, IP30
ADEAIB
Internal control board
ADEAGD1
Additional control board to acheive BMS functionality
KRT2800
2-step room thermostat, IP55
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
40001
2-step room thermostat, IP55
T10
Room thermostat, IP30
KRT1900
Room thermostat, IP55
MDC
Magnetic door contact with time relay, IP44
KUR
Digital time switch, IP55
CBT
Electronic timer, IP44
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
22003
False ceiling grille 1192 mm
22004
False ceiling grille 1515 mm
ADPK1
Suspension kit, max 1 m
ADPF1
Suspension brackets (pair)
More information about accessories on pages 30-31 and 62-66.
A i r cur t ai ns
Air curtains - Thermozone® Industry
Thermozone® AD400A/E/W
Thermozone AD400W, water heated (IP20)
Installation height up to 4 metres
Combines high performance with a
compact size and an elegant design.
Recessed mounting possible.
Height: 340 mm
Depth: 490 mm
Colour: white, RAL 9016.
Approved by SEMKO and CE compliant.
Type
4m
Heat
Airflow
Sound level Length
output*
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AD410W3 230V~
25
2300
53/62
1025
AD415W3 230V~
43
3800
39/63
1565
AD420W3 230V~
56
4800
55/65
2028
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
1 / 1,5 / 2 m
Thermozone AD400A, ambient, unheated (IP20)
Type
AD410A
AD415A
AD420A
Voltage
[V]
230V~
230V~
230V~
Heat output
[kW]
0
0
0
Airflow
[m³/h]
2500
4200
5000
1
Sound level
[dB(A)]
48/63
35/64
50/65
Length
[mm]
1025
1565
2028
CB30N and
MDC, magnetic door contact with time relay
Thermozone AD400E, electrically heated (IP20)
Type
Voltage
AD410E14
AD415E20
AD420E27
[V]
400V3~
400V3~
400V3~
Heat
output
[kW]
0/9/13,5
0/13,5/20
0/18/27
Airflow
[m³/h]
2500
4200
5000
CB32N, RTI2 and
MDC, magnetic door contact with time relay
CK03
Level 3
ADEA, air curtain control with outdoor sensor,
built-in room sensor and door contact
ADEAIS, external room sensor
ADEAEB*, external control board
[mm]
1025
1565
2028
*) ADEAEB can be replaced by internal control board ADEAIB, all items
must then be ordered separately and not as a kit.
Conditions for sound level measurements, see page 67.
CB30N and RTI2, 2-step room thermostat
MDC, magnetic door contact with time relay
CK03
Level 3
ADEA, air curtain control with outdoor sensor,
built-in room sensor and door contact
ADEAIS, external room sensor
ADEAEB*, external control board
Accessories - AD400A/E/W
Length
Control kits AD400E 3
CK01E
CB32N, controls the airflow in 3 steps and the heat
Level 1
output in 2 steps
RTI2, 2-step room thermostat
CK02E
Level 2
CK02W
Level 2
Note! A valve set VR20/25 (option: TVV20/25 with SD20) should
be added for a complete control kit.
3
Sound
level
[dB(A)]
48/63
35/64
50/65
Control kits AD400W 2
CK01W
CB30N, controls the airflow in 3 steps
Level 1
T10, room thermostat
*) ADEAEB can be replaced by internal control board ADEAIB, all items
must then be ordered separately and not as a kit.
Control kits AD400A 1
Level 1
CB30N, controls the airflow in 3 steps
Level 2
2
Voltage
Type
Description
CK01E
Control kit Electric level 1 (CB32N, RTI2)
CK02E
Control kit Electric level 2 (CB32N, RTI2, MDC)
CK03
Control kit level 3 (ADEA, ADEAIS, ADEAEB)
CK01W
Control kit Water level 1 (CB30N, T10)
CK02W
Control kit Water level 2 (CB30N, RTI2, MDC)
CB30N
Control box (A/W)
CB32N
Control box (E)
ADSR54
Stepless fan speed control, IP54
ADEA
Air curtain control
ADEAEB
External control board, IP55
ADEAIS
External room sensor, IP30
ADEAIB
Internal control board
ADEAGD
Additional control board to acheive BMS functionality
KRT2800
2-step room thermostat, IP55
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
40001
2-step room thermostat, IP55
T10
Room thermostat, IP30
KRT1900
Room thermostat, IP55
MDC
Magnetic door contact with time relay, IP44
AGB304
Door contact, IP44
KUR
Digital time switch, IP55
CBT
Electronic timer, IP44
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
22003
False ceiling grille 1192 mm
22004
False ceiling grille 1515 mm
ADPK1
Suspension kit, max 1 m
ADPF1
Suspension brackets (pair)
More information about accessories on pages 30-31 and 62-66.
21
3,5 / 4,2 m
Air curtains - Thermozone® Entrance
1 / 1,5 / 2 / 2,5 m
1,5 / 2 / 2,5 m
Thermozone® PA3500/4200
Air curtain PA3500/4200 gives more possibilities than ever
before, packed into the same product. There are therefore
many areas of use. PA3500/4200 has a modern and stylish
design developed to fit all entrances. The air curtain is
available for horizontal, vertical and recessed installation.
•Colourfrontandservicehatch:RAL9016,NCS0500(white).
Colour grille, rear section and ends: RAL 7046 (grey).
Thermozone® PA3500
Thermozone® PA4200
PA3500 is particularly suitable in entrances to stores and
shopping centres for example.
•Installationheightupto3,5metres
•Installationwidthupto5metres(2units)
•Height:270mm
•Depth:525mm
•CEcompliant.
PA4200 is specifically designed for doorways in for example,
industrial and warehouse buildings or large commercial
installations.
•Installationheightupto4,2metres
•Installationwidthupto6metres(2units)
•Height:295mm
•Depth:611mm
•CEcompliant.
Thermozone PA3500 A, ambient, unheated (IP20) 1
Type
Voltage
PA3510A
PA3515A
PA3520A
PA3525A
[V]
230V~
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
0
Airflow
[m³/h]
1800
2600
3200
4600
Sound
level
[dB(A)]
40/57
41/59
42/60
42/61
Thermozone PA4200 A, ambient, unheated (IP20) 1
Length
Type
Voltage
[mm]
1039
1549
2039
2549
PA4210A
PA4215A
PA4220A
PA4225A
[V]
230V~
230V~
230V~
230V~
Thermozone PA3500 E, electrically heated (IP20) 3
Type
Voltage
PA3510E08
PA3515E12
PA3520E16
PA3525E20
[V]
230V~/400V3~
230V~/400V3~
230V~/400V3~
230V~/400V3~
Heat
output
[kW]
2,7/5,4/8,0
3,9/7,8/12,0
5,4/10,8/16,0
6,6/13,2/20,0
Airflow Sound
level
[m³/h] [dB(A)]
1800
40/57
2600
41/59
3200
42/60
4600
42/61
Voltage
• Longer3mmodel
• ModelwithECmotorsfor
extra energy efficiency
• WatercoilWLLforverylow
water temperatures
22
Airflow
[m³/h]
2700
3700
5300
6350
Sound
level
[dB(A)]
46/64
46/64
47/65
49/67
Length
[mm]
1039
1549
2039
2549
Thermozone PA4200 E, electrically heated (IP20) 3
Type
Voltage
[mm]
1039
1549
2039
2549
PA4210E12
PA4215E18
PA4220E24
PA4225E30
[V]
230V~/400V3~
230V~/400V3~
230V~/400V3~
230V~/400V3~
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
PA3510WL
230V~
22
1800
40/57
1039
PA3515WL
230V~
33
2600
41/59
1549
PA3520WL
230V~
42
3200
42/60
2039
PA3525WL
230V~
59
4600
42/61
2549
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
Future models:
Heat
output
[kW]
0
0
0
0
Length
Thermozone PA3500 WL, water heated (IP20) 2
Type
5/6m
Heat
output
[kW]
3,9/7,8/12,0
6,0/12,0/18,0
7,8/15,6/24,0
9,9/19,8/30,0
Airflow Sound
level
[m³/h] [dB(A)]
2700
46/64
3700
46/64
5300
47/65
6350
49/67
Length
[mm]
1039
1549
2039
2549
Thermozone PA4200 WL, water heated (IP20) 2
Type
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
PA4210WL
230V~
31
2700
46/64
1039
PA4215WL
230V~
45
3700
46/64
1549
PA4220WL
230V~
64
5300
47/65
2039
PA4225WL
230V~
79
6350
49/67
2549
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
Recessed mounting in false ceiling
PA3XT/PA4XT, outlet extension
Outlet extension with telescopic function. Used for
recessed installation of units in suspended ceilings.
Horizontal mounting
PA34WB, wall brackets
Brackets for installing unit horizontally on a wall.
PA34CB, ceiling brackets
Ceiling brackets for installing the unit from the ceiling using wires
or threaded bars (not included). Best combined with vibration
dampers (PA34VD) when using threaded bars.
PA34WS, wire suspension kit
Galvanized wires with wire locks to secure the unit from the
ceiling. Used together with ceiling brackets (PA34CB).
Control options
This air curtain is supplied with an intregrated PC board SIRe.
SIRe is an intelligent and well designed low voltage control
system which can be customised for each unique application
and environment. SIRe is supplied pre-programmed with quick
fit plug connections and is very easy to use and install. If more
than one air curtain should be controlled by a single SIRe, an
additional modular cable SIReCC per unit is needed. Cables
between units can easily be joined together by using joint
piece SIReCJ. There are three different levels with different
functionality to choose from, Basic, Competent or Advanced.
Valve kit VOS(P), VOT, VMO(P) or VMT is used to control the
water flow, see final section of this catalogue.
A i r cur t ai ns
Air curtains - Thermozone® Industry
PA34TR, threaded bars
Threaded bars for installing unit on to a ceiling. Used together
with ceiling brackets (PA34CB). Supplemented with vibration
dampers (PA34VD) for reduced vibration.
PA3JK/PA4JK, joining kit
Used to join horizontal units together for a sleek and unified
installation. Consists of joint bracket and mounting parts.
PA3DW/PA4DW, design kit for wall mounting
Gives a neater installation on the wall by covering mountings,
cables and pipes. Used together with wall brackets PA34WB.
PA3DC/PA4DC, design kit for ceiling mounting
Gives a neater installation on the ceiling by covering mountings,
cables and pipes. Consists of start parts, intermediate parts and
telescopic parts for attachment to ceilings. The design kit can
also be used for non-recessed mounting in suspended ceilings,
telescopic parts are however not then needed. The kit can be
combined with any type of ceiling mounting (wires, rods, etc.) No
start parts are needed for PA4200. For more information about
the design kit, see www.frico.se.
Vertical mounting
PA3JK/PA4JK, vertical kit
Used to adapt a horizontal unit for a vertical installation. Consists
of floor edging, mounting parts and bracket to brace the top of the
unit. The edging is also used as a joint bracket making it possible
to mount two units on top of each other.
PA3VDW/PA4VDW, design kit for vertical mounting
Gives a neater vertical installation by covering cables and pipes.
PA3HE/PA4HE, extension hood
Fills the space between the unit and the ceiling for vertical
mounting and provides a neater installation. Special order to
required dimension.
Horizontal and vertical mounting
PA34EF, external intake filter
Fine mesh filter that prevents ingress of dirt and deposits to
the unit. The filter is easy to attach and remove thanks to the
integrated magnetic strips. Makes maintenance easier since the
unit does not need to be opened.
FHDN20, flexible hoses
Flexible hoses for easy and practical installation of water heated
unit.
Accessories - PA3500/4200A/E/W
Type
Description
SIReB
SIReAC
SIReAA
PA34WB15
PA34WB20
PA34WB30
PA34CB15
PA34CB20
PA34CB30
PA34WS15
PA34WS20
PA34WS30
PA34TR15
PA34TR20
PA34TR30
PA34VD15
PA34VD20
PA34VD30
PA3JK
PA4JK
PA3DW10
PA3DW15
PA3DW20
PA3DW25
PA4DW10
PA4DW15
PA4DW20
PA4DW25
PA3XT10
PA3XT15
PA3XT20
PA3XT25
PA4XT10
PA4XT15
PA4XT20
PA4XT25
PA3JK
PA4JK
PA3VDW15
PA3VDW20
PA3VDW25
PA4VDW15
PA4VDW20
PA4VDW25
PA3HE
PA4HE
PA34EF10
PA34EF15
PA34EF20
PA34EF25
FHDN20
Control system SIRe Basic
Control system SIRe Competent
Control system SIRe Advanced
Wall brackets for PA3510/3515/4210/4215
Wall brackets for PA3520/4220
Wall brackets for PA3525/4225
Ceiling brackets for PA3510/3515/4210/4215
Ceiling brackets for PA3520/4220
Ceiling brackets for PA3525/4225
Wire suspension kit for PA3510/3515/4210/4215
Wire suspension kit for PA3520/4220
Wire suspension kit for PA3525/4225
Threaded bars for PA3510/3215/4210/4215
Threaded bars for PA3520/4220
Threaded bars for PA3525/4225
Vibration dampers for PA3510/3515/4210/4215
Vibration dampers for PA3520/4220
Vibration dampers for PA3525/4225
Joining kit PA3500
Joining kit PA4200
Design kit for wall mounting PA3510
Design kit for wall mounting PA3515
Design kit for wall mounting PA3520
Design kit for wall mounting PA3525
Design kit for wall mounting PA4210
Design kit for wall mounting PA4215
Design kit for wall mounting PA4220
Design kit for wall mounting PA4225
Outlet extension for PA3510, 130-200 mm
Outlet extension for PA3515, 130-200 mm
Outlet extension for PA3520, 130-200 mm
Outlet extension for PA3525, 130-200 mm
Outlet extension for PA4210, 130-200 mm
Outlet extension for PA4215, 130-200 mm
Outlet extension for PA4220, 130-200 mm
Outlet extension for PA4225, 130-200 mm
Vertical kit for PA3500
Vertical kit for PA4200
Design kit for vertical mounting PA3515
Design kit for vertical mounting PA3520
Design kit for vertical mounting PA3525
Design kit for vertical mounting PA4215
Design kit for vertical mounting PA4220
Design kit for vertical mounting PA4225
Extension hood for PA3500
Extension hood for PA4200
External intake filtre for PA3510/4210
External intake filtre for PA3515/4215
External intake filtre for PA3520/4220
External intake filtre for PA3525/4225
Flexible hoses DN20, inside thread, 90° bend
23
Air curtains - Thermozone® Industry
Thermozone® AG4500/5000A/W
Accessories - AG4500/5000A/W
Installation height up to 5 metres.
Clean, stylish and simple design.
Height: 450 mm
Depth: 750 mm
Colour: white, RAL 9016.
CE compliant.
5m
Type
1/1,5/2/2,5m
Thermozone AG4500/5000A, ambient, unheated (IP23)
Type
Voltage
AG4515A
AG4520A
AG4525A
AG5010A
AG5015A
AG5020A
AG5025A
[V]
230V~
230V~
230V~
230V~
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
0
0
0
0
Airflow
[m³/h]
5300
7600
10200
4700
7100
9300
11600
Sound
level
[dB(A)]
48/67
50/69
51/70
48/67
50/69
51/70
52/71
1
Length
[mm]
1500
2000
2500
1000
1500
2000
2500
Control kits AG4500/5000A 1
Level 1
CB30N, controls the airflow in 3 steps
Level 2
CB30N and MDC, magnetic door contact with time
relay
Description
Control kit Water level 1 (CB30N, T10)
Control kit Water level 2 (CB30N, RTI2, MDC)
Control kit level 3 (ADEA, ADEAIS, ADEAEB, ADEAGD1)
Control box (A/W)
Control box (E)
Air curtain control
External control board, IP55
External room sensor, IP30
Additional control board to acheive ADEA and BMS
functionality
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
T10
Room thermostat, IP30
KRT1900
Room thermostat, IP55
MDC
Magnetic door contact with time relay, IP44
AGB304
Door contact, IP44
KUR
Digital time switch, IP55
CBT
Electronic timer, IP44
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
GWB640
Wall bracket. AG4510/4515 and AG5010/5015 require 2
pcs. AG4520/AG4525 and AG5020/AG5025 require 3 pcs.
More information about accessories on pages 30-31 and 62-66.
CK01W
CK02W
CK03GD
CB30N
CB32N
ADEA
ADEAEB
ADEAIS
ADEAGD1
Product specific accessories, AG4500/5000
Thermozone AG4500/5000W, water heated (IP23)
Type
2
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AG4515WL
230V~
44
4800
48/67
1500
AG4520WL
230V~
71
7000
50/69
2000
AG4525WL
230V~
92
9400
51/70
2500
AG5010WL
230V~
43
4200
48/67
1000
AG5015WL
230V~
56
6500
50/69
1500
AG5020WL
230V~
81
8500
51/70
2000
AG5020WL
230V~
100
10600
52/71
2500
*) Applicable at water temperature 80/60 °C, air temperature, in +15 ºC.
Control kits AG4500/5000W 2
CK01W
CB30N, controls the airflow in 3 steps
Level 1
T10, room thermostat
CK02W
Level 2
CB30N and RTI2, 2-step room thermostat
MDC, magnetic door contact with time relay
CK03GD
Level 3
ADEA, air curtain control with outdoor sensor,
built-in room sensor and door contact
ADEAIS, external room sensor
ADEAEB, external control board
ADEAGD1, extra control board
Note! A valve set VR20/25 (option: TVV20/25 with SD20) should
be added for a complete control kit.
24
Conditions for sound level measurements, see page 67.
GWB, wall bracket
The brackets are screwed into place in the wall.
The air curtain is then suspended from the
brackets using threaded bars. 2 brackets are
needed for units up to 1,5 metres and 3 brackets
are needed for 2 and 2,5 metre units.
4-8 m
A i r cur t ai ns
Air curtains - Thermozone® Industry
3-8 m
UF600
Installation height 3 - 6 metres.
Can also be mounted vertically.
Without heat.
Height: 785 mm
Depth: 520 mm
Colour: white, RAL 9016.
CE compliant.
UF600 consists of one or two pillars with inlet
hood, silencers and fans, as well as a floor
channel with its slot at floor level. The pillars
are placed inside or outside the door on either
(or both) sides of the opening. Air at high
speed is pressed out through the narrow slot
in the floor at the door opening.
The width of the slot and the blow angle are
adapted to the opening. Complete slot with
inspection hatch could be custom made.
UF600 creates a very effective air barrier
at the door opening, when pressing air at
high speed out through a narrow slot. The
air curtain is angled upwards and gives best
possible protection against colder and heavier
air getting into the building.
Diameter: 700/900 mm
Colour: grey.
CE compliant.
3-6 m
Thermozone® AC500
1 / 1,5 m
Thermozone AC500, ambient, unheated (IP24)
Type
AC501
AC502
Voltage
Heat
output
[V]
[kW]
230V~/400V3~ 0
230V~/400V3~ 0
Airflow
[m³/h]
5200
7700
1
Sound
level
[dB(A)]
63
65
Length
[mm]
1030
1550
Control kits AC500 1
Level 1
AGB304, door contact, starts/stops the air curtain
when the door is opened/closed
RTRD7, RTRD14, 5-step fan speed control
Level 2
AGB304 and
PKDM12, stepless fan speed control, high/low speed
Accessories - AC500
Type
Description
RTRD7
5-step fan speed control, Max 7 A
RTRD14
5-step fan speed control, Max 14 A
RTRDU7
5-step fan speed control, high/low speed
PKDM12
Stepless fan speed control, high/low speed
AGB304
Door contact, IP44
More information about accessories on pages 30-31 and below.
UF600, ambient, unheated (IPX4)
Type
Voltage
[V]
UF601
400V3~
UF602
400V3~
UF603
400V3~
UF604
400V3~
UF605
400V3~
UF606*
400V3~
*) UF606 consists of two pillars.
1
Max door dimensions
HxW
[m]
3x4
3x6
4x5
4x6
6x6
5x8
Control UF600 1
For more information please visit www.frico.se.
Product specific accessories, AC500
PKDM12, 3-phase stepless fan speed control
The appropriate fan speed is set for open and
closed door respectively (high/low speed). The fan
speed can be controlled with an external 0–10 V
signal. Max input 12 A. IP54.
Conditions for sound level measurements, see page 67.
25
1,2 / 1,8 / 2,4 / 3,0 m
Air curtains - Thermozone® Industry
Thermozone® AGI A/W
1,2 / 1,8 / 2,4 / 3,0 m
Thermozone AGI is a robust air curtain
for industrial doors that can be mounted
horizontally or vertically. Four module
lengths means you can easily combine the
curtains to cover the individual needs of
every door.
An adjustable air blower grille allows you
to direct the airflow to achieve an optimal
air curtain effect.
Width: 730 mm
Depth: 490 mm
Colour: grey, RAL 9006.
CE compliant.
Thermozone AGI W, water heated, vertical mounting, (IP54)
Type
Heat
Airflow
Sound
Height
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AGIV2WL
400V3~
50
7000
69
1200
AGIV3WL
400V3~
77
10500
71
1800
AGIV4WL
400V3~
106
14000
72
2400
AGIV5WL
400V3~
132
17500
73
3000
*) Applicable at water temperature 80/60 °C, air temperature, in +15 ºC.
Thermozone AGI A, ambient, unheated, vertical mounting,
(IP54) 1
Type
Voltage
AGIV2A
AGIV3A
AGIV4A
AGIV5A
[V]
400V3~
400V3~
400V3~
400V3~
Heat
output
[kW]
0
0
0
0
Airflow
[m³/h]
7000
10500
14000
17500
Sound
level
[dB(A)]
69
71
72
73
Height
[mm]
1200
1800
2400
3000
Thermozone AGI A, ambient, unheated, horizontal mounting,
(IP54) 1
Type
Voltage
AGIH2A
AGIH3A
AGIH4A
AGIH5A
[V]
400V3~
400V3~
400V3~
400V3~
Heat
output
[kW]
0
0
0
0
Airflow
[m³/h]
7000
10500
14000
17500
Sound
level
[dB(A)]
69
71
72
73
Length
[mm]
1200
1800
2400
3000
Control kits AGI A 1
Level 1
AGB304, door contact, starts/stops the air curtain
when the door is opened/closed
RTRD7, RTRD14, 5-step fan speed control
26
2
Voltage
Conditions for sound level measurements, see page 67.
Thermozone AGI W, water heated, horizontal mounting,
(IP54) 2
Type
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AGIH2WL
400V3~
56
7000
69
1200
AGIH3WL
400V3~
86
10500
71
1800
AGIH4WL
400V3~
118
14000
72
2400
AGIH5WL
400V3~
147
17500
73
3000
*) Applicable at water temperature 80/60 °C, air temperature, in +15 ºC.
Control kit s AGI W 2
Level 1
RTRD7, RTRD14, 5-step fan speed control
T10, room thermostat
Level 2
RTRD, T10 and
MDC, magnetic door contact with time relay
Accessories - AGI A/W
Type
Description
RTRD7
5-step fan speed control, Max 7 A
RTRD14
5-step fan speed control, Max 14 A
RTRDU7
5-step fan speed control, Max 7 A, high/low speed
T10
Room thermostat, IP30
KRT1900
Room thermostat, IP55
MDC
Magnetic door contact with time relay, IP44
AGB304
Door contact, IP44
KUR
Digital time switch, IP55
CBT
Electronic timer, IP44
VR25
Valve set, DN 25 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
More information about accessories on pages 30-31 and 62-66.
Our cool models
Frico offers several models without heat that are suitable for
keeping the cold in cold storages. Choose the appropriate unit
according to the dimensions of the opening. There are units for
horizontal and vertical mounting and in different designs.
Thermozone® ADA Cool
Horizontal mounting
For cold storage openings.
Installation height up to 2,5 metres.
Suitable where space is limited between the
ceiling and the upper edge of the doorway.
With cable and plug.
Should be mounted on the outside
(warm side).
ADAC has a simple connection making
it possible to link units together in order
to cover wide openings such as open cold
storages. All connections are done with
cable and plug, including the control.
Recessed mounting possible.
Height: 235 mm
Depth: 215 mm
Colour: white, RAL 9016.
CE compliant.
Installation height up to 2,5 m
A i r cur t ai ns
Air curtains - Thermozone® Cold storage
2,5 m
ADA Cool
AD200A
Lengths: 1, 1,5 and 2 metres.
AD200
0,9 / 1,2 m
Installation height up to 3,5 m
PA3500A
Lengths: 1, 1,5, 2 and 2,5 metres.
AD300A
Lengths: 1, 1,5 and 2 metres.
AD300/400
Thermozone ADA Cool, ambient, unheated (IP22)
Type
Voltage
ADAC090
ADAC120
[V]
230V~
230V~
Heat
output
[kW]
0
0
Airflow
[m³/h]
1150
1400
1
Sound
level
[dB(A)]
54
51
Length
[mm]
900
1200
Description
ADACR
5-step fan speed control
AD400A
Lengths: 1, 1,5 and 2 metres.
Installation height up to 4,2 m
Accessories - ADA Cool
Type
Installation height up to 4 m
PA3500/4200
PA4200A
Lengths: 1, 1,5, 2 and 2,5 metres.
Installation height up to 5 m
Product specific accessories, ADA Cool
AG4500A and AG5000A
Lengths: 1, 1,5, 2 and 2,5 metres.
2,2 m
ADACR, 5-step fan speed control
ADACR is a control and connection set
consisting of a 5-step fan speed control,
flexible cable and earthed plug. Can control a
maximum of 7-9 units (max. 7 units at 60 Hz).
Max input: 5 A.
Dimensions: 200x105x105 mm. IP30.
ADACR
5A
AG4500/5000
Vertical mounting
Installation width up to 3,5 m
2,2 m
PA3500A
Heights: 1,5, 2 and 2,5 metres.
Installation width up to 4,2 m
PA4200A
Heights: 1,5, 2 and 2,5 metres.
PA3500/4200
Conditions for sound level measurements, see page 67.
27
Air curtains - Thermozone® Controls
SIReB Basic
SIReAC Competent
ur
e
m
rat
ste
pe
-sy
em
MS
rn
xl
im
it o
fr
e tu
Ad
v
an
ce
wa
te
rt
dB
er
ti v
Pro
ac
Co
mf
eg
ort
ula
mo
tio
n
de
e
od
om
sy
SBM
ple
Ec
ste
m
rm
ala
Sim
un
rf
da
Ca
len
Fil
te r
cti
on
de
en
Op
xib
Fle
mo
e
od
le
m
mo
tic
ma
Au
to
Ma
nu
al
op
era
tio
n
de
SIReAA Advanced
SIRe is an intelligent and well designed low voltage control
system which can be customised for each unique application
and environment. SIRe is supplied pre-programmed with quick
fit plug connections and is very easy to use and install. The
control system is pre-installed in air curtains PA3500, PA4200,
AR3500 and AD Corinte with an integrated PC board.
SIRe learns the requirements in the entrance it is installed
in (e.g. opening frequency and outdoor temperature). It has
calendar function and selectable switch off at set temperatures
for up to nine units. Because the fan speed is adapted, the
sound level is optimised and is never higher than is necessary
for comfort. With SIRe Advanced it is possible to choose
between Eco and Comfort mode dependent on whether energy
savings or optimal comfort has been prioritised.
There are three different levels with different functionality to
choose from, Basic, Competent or Advanced.
Functions SIReB Basic
•Manualregulationofthefanandtemperature
•Automaticcontroloffanspeedandtemperaturewith
integrated thermostat.
Functions SIReAC Competent
•AllfunctionsforBasic
•Calendarfunction
•Filteralarm
•SimpleBMScontrol-on/off,fanspeedandalarmfunctions
•Flexiblemode-fordoorsthatopenandclosefrequently
•Openmode-fordoorsthatstayopen
Functions SIReAA Advanced
•AllfunctionsforCompetent
•Ecomode-extraenergy-efficientmode
•Comfortmode-whencomfortisimportant
•AdvancedBMScontrol
•Proactiveregulation–measuresoutdoortemperaturesfor
proactive reaction.
28
Ma
Control system SIRe
Included in SIReB Basic:
•SIReB1,integratedPCboardBase
•SIReIT,internaltemperaturesensor
•SIReUB1,controlunit.Wallunitcoverincluded.
•SIReCC,modularcable,RJ12(6/6),5m
Options:
•SIReRTX,externalroomtemperaturesensor
•VOS(P),(pressureindependent)valvekiton/offorVOT,three
way valve and actuator on/off
Included in SIReAC Competent:
•SIReB1,integratedPCboardBase
•SIReIT,internaltemperaturesensor
•SIReUA1,controlunit.Wallunitcoverincluded.
•SIReC1X,PCboardHUBCompetent
•SIReDC,doorcontact
•SIReCC,modularcables,RJ12(6/6),3mresp.5m
Options:
•SIReRTX,externalroomtemperaturesensor
•SIReUR,kitforrecessedinstallation
•VOS(P),(pressureindependent)valvekiton/offorVOT,three
way valve and actuator on/off
Included in SIReAA Advanced:
•SIReB1,integratedPCboardBase
•SIReIT,internaltemperaturesensor
•SIReUA1,controlunit.Wallunitcoverincluded.
•SIReA1X,PCboardHUBAdvanced
•SIReOTX,outdoortemperaturesensor
•SIReDC,doorcontact
•SIReCC,modularcables,RJ12(6/6),3mresp.5m
Options:
•SIReRTX,externalroomtemperaturesensor
•SIReUR,kitforrecessedinstallation
•SIReWTA,clamp-onsensor
•VMO(P),(pressureindependent)modulatingvalvekitor
VMT, three way valve and modulating actuator
Air conditioner
control
Building
Management
System
SIReDC
A i r cur t ai ns
Air curtains - Thermozone® Controls
Elevator control
Fire alarm system
SIReRTX/OTX
SIReUR
SIReWTA
Entrance control
Air curtain control
Integration of air curtains AR3500, AD Corinte, PA3500 and
PA4200 in an overall control system (BMS)
BMS-control - level 1
With SIRe Competent the above air curtains can be integrated
in an overall control system (BMS). The air curtain can be
started/stopped and the fan speed regulated via the BMS
system. A 5-30V control signal is required for starting/stopping.
A 0-10V control signal is required to control the fan speed.
Potential free contact for buzzer.
BMS-control - level 2
With SIRe Advanced the above air curtains can be integrated
in an overall control system (BMS). The air curtain can be
started/stopped, the fan speed and heating regulated smoothly
via the BMS system. A 5-30V control signal is required for
starting/stopping. A 0-10V control signal is required to control
the fan speed and heating. Input for alarm and night reduction
via external potential free contact. Potential free contact for
buzzer and operation indication.
BMS-control - level 3
With SIRe Advanced it is also possible to communicate via
Modbus RTU (RS485). Contact Frico for more information.
Control system SIRe
Type
Description
SIReB
SIReAC
SIReAA
Control system SIRe Basic
Control system SIRe Competent
Control system SIRe Advanced
Accessories - SIRe
Type
Description
SIReRTX
SIReUR
SIReWTA
SIReCJ4
SIReCJ6
SIReCC603
SIReCC605
External room temperature sensor
Kit for recessed installation
Clamp-on sensor
Used to join two RJ11(4/4)
Used to join two RJ12 (6/6)
Modular cable RJ12 3 m
Modular cable RJ12 5 m
Modular cable RJ12 10 m
Modular cable RJ12 15 m
Modular cable RJ11 3 m
Modular cable RJ11 5 m
Modular cable RJ11 10 m
Modular cable RJ11 15 m
SIReCC610
SIReCC615
SIReCC403
SIReCC405
SIReCC410
SIReCC415
Water control
Valve kit VOS(P), VOT, VMO(P) or VMT is used to control the
water flow, see final section of this catalogue.
29
Air curtains - Thermozone® Controls
ADEA
CB22/
CB32N
ADSR54
CB30N
RTRD7
RTRD14
RTRDU7
ADEA, air curtain control
ADSR54, stepless fan speed control
For Portier, AD, ACC, AG. An outdoor sensor, room sensor and
door contact govern the control, which adapts the heat and fan
speed, according to the preset parameters, to the prevailing
conditions.
In its basic design the fan speed is controlled in 3 steps, but
can, via a 0-10 V signal, govern an external controller (ADSR54
or frequency inverter) to provide fully variable control.
A control board needs to be added, ADEAIB for internal
mounting (for AD300/400 only) or ADEAEB (IP55) for external
mounting (for all units). Depending on the motor current, one
or more units may be controlled with one control board.
An extra control board ADEAGD1 is needed to control AG
and ACC air curtains. The control board also makes it possible
to connect any Frico air curtain running with ADEA to an
advanced BMS system.
For AD200/300/400 A/W. For unheated and water heated air
curtains (single phase supply 230 V~, max 3 A). Controls the
motor without causing disturbing electro magnetic noise. Can
be controlled with an external 0–10 V signal. Max. input 3 A,
230 V~. IP54.
RTRD7, 5-step fan speed control
For AC500 and AGI. With RTRD7 the air velocity is adjusted
in 5 steps for optimum efficiency. The air velocity is set to
accommodate different external conditions. Max input 7 A.
IP21.
RTRD14, 5-step fan speed control
For AC500 and AGI. With RTRD14 the air velocity is adjusted
in 5 steps for optimum efficiency. The air velocity is set to
accommodate different external conditions. Max input 14 A.
IP21.
CB22, control box
For Portier. Controls the airflow in 2 steps and heat output in
2 steps. CB22 is used for electrically heated units. Can control
several units. Max input 10 A. IP44.
RTRDU7, 5-step fan speed control (high/low speed)
For AC500 and AGI. With RTRDU7 the air velocity is set in 5
steps for maximum efficiency. When the door is closed the fan
runs at a preset low speed to keep the room warm, when the
door is open the fan is preset at a high speed to accommodate
different external conditions. Max input 7 A. IP21.
CB20, control box
For Portier. Controls the airflow in 2 steps. CB20 is used for
unheated units. Can control several units. Max input 10 A.
IP44.
CB32N, control box
For AD E, AR200 E, AG E, AC Corinte E, SF E and RD E.
Controls the airflow in 3 steps and heat output in 2 steps.
CB32N is used for electrically heated units. Can control several
units. Max input 10 A. IP44.
CB30N, control box
For AD A/W, AR200 A/W, AG A/W, AC Corinte W, SF W and RD
W. Controls the airflow in 3 steps. CB30N is used for unheated
and water heated units. Can control several units. Max input
10 A. IP44.
Portier
A
ADEA
Air curtain control
E
A
E
AD 200/300/400
W
A
X
E
W
X
X
SF, RD
E
W
AC Corinte
AG4500/5000
A
E
W
X
X
ADEAOS
Outdoor sensor
X
X
X
X
X
ADEAEB
External control board
X
X
X
X
X
ADEAIB
Internal control board
X *¹
X*¹
ADEAIS
External room sensor
X
X
X
X
X
ADEAGD1
Extra control board for ADEAEB, BMS
X
X
X
X*2
X*2
AC500
AGI
A
W
CB20
Control box
CB22
Control box
X
CB30N
Control box
CB32N
Control box
ADSR54
Stepless fan speed control
RTRD7
5-step fan speed control
X
X
RTRD14
5-step fan speed control
X
X
X
X
X
RTRDU7
5-step fan speed control
*¹) only for AD300/400.
*²) ADEAGD1 is required when ADEA is used with these products.
*3) Max.input 3A.
30
AR200
X
X
X
X
X
X
X*3
X
X
X
X
X
X*3
A i r cur t ai ns
Air curtains - Thermozone® Accessories
ADPF
ADPK1
4x
2x
MDC
MDCDC
AGB304
22003, 22004
AXP300
MDC, magnetic door contact with time relay
22003, 22004, false ceiling grille
Starts the air curtain or increases from low to high speed when
the door is opened. When the door is closed, the fan continues
to run for the preset time (2 s–10 min). Prevents the fan from
starting/stopping continuously and is especially suitable for
doors that are frequently opened. Three alternating volt-free
contacts 10 A, 230 V~. Is activated by a volt-free make. A
MDCDC is included in MDC. IP44.
For AD200/300/400. Primarily used as air inlet grille when
the air curtain is recessed into a false ceiling. Available in two
sizes; 1192x192 mm and 1515x192 mm. Colour: white.
ADPK1, suspension kit
For AD200/300/400 and Portier. Mounting kit for suspension
mounting of the AD-range. Consists of 2 hanging brackets,
length 1 metre, and 4 bracket fixtures, 2 for the unit and 2 for
the ceiling.
The hanging brackets are covered by a white plastic trim to
cover the cables. The brackets may be cut to shorter length,
if required. Note! The 2-metres AD-units need 3 fixing points.
Colour: white.
MDCDC, magnetic door contact
Indicates door status. Extra MDCDC are used when several
doors are connected to a MDC. IP44.
AGB304, door contact
Starts the air curtain or activates a fan speed control when
the door is opened. When the door closes, AGB304 stops the
air curtain or changes fan speed through a fan speed control.
Alternating contact 4 A, 230 V~. IP44.
ADPF1, suspension brackets
For AD200/300/400 and Portier. Suspension brackets for the
AD-range. Consists of 4 brackets, 2 for the unit and 2 for the
ceiling. Note! The 2-metres long AD-units need 3 fixing points.
Colour: white.
AXP300, collision protection
AXP300ismountedonthegroundnexttoaverticalaircurtain
to prevent it from being hit by trucks, shopping trolleys and
similar. Colour: metal grey.
Portier
MDC
AC Corinte
AR200
AD 200/300/400
RD, SF
E
E
W
A
E
W
A
E
W
E
W
A
E
W
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AGB304
22003
22004
ADPK1
X
ADPF1
X
AXP300
AG4500/5000
X
X
X
AC500
A
AGI
A
UF600
W
A
X
X
X
X
X
X
31
Radiant heaters
Heating with radiant heaters is indirect. The heat is
transferred from the radiant heaters at the ceiling to
surfaces such as floors, walls, fixtures and the like,
which in their turn give off heat to the air in the room.
No losses occur on the way from ceiling to floor.
Radiant heating can be compared to ordinary light.
Dispersion and reflection occur in relatively the same
way.
Radiant heaters create a very equal temperature
distribution between floor and ceiling. The expensive
cushion of overheated air that is easily formed when using
other heating systems can be avoided. In rooms with high
ceilings, radiant heaters give significantly lower energy
consumption.
Total heating
Radiant heaters heat people first, then the air. The
operative temperature, being the temperature a person
senses, is therefore a little higher than the actual air
temperature.
For a specific comfort level, use of a radiant heating
system will allow a reduction in air temperature of a couple
of degrees when compared to a conventional system, and
every degree reduction will reduce energy consumption by
approx. 5 %.
Zone and spot heating
There are many advantages with radiant heaters:
Economy
• Heatpeopleandobjectsfirstandthenthesurrounding
air. This allows the temperature to be reduced while
maintaining comfort.
• Producesinstantheat,thusmuchquickerthan
traditional heating systems. This is especially useful
outdoor and in buildings that is used occasionally such
as sport centres and country houses.
• Heatatfloorlevel,notattheceiling.
• Reducednighttemperturepossiblewithrightcontrols
thanks to quick heat-up time.
With a radiant heating system, different zones within the
same room can have different temperatures. It is therefore
possible to divide any area into smaller zones and maintain
a different comfort level in each zone.
It is also possible to focus the heat on a certain spot, such
as a single workstation. A spot heating application can be
controlled much as spot lighting, with the level of heating
being increased when needed.
Safety
Complementary heating
Simplicity
As addition to other heating systems and when expanding
an existing system, radiant heaters are often a simple,
inexpensive solution. For a water heated building, putting
up a single or a few electrical heaters is often a smoother
and more flexible solution than extending the water pipe
system.
Cold draught protection
A cool surface such as a window has a chilling effect on
the neighbouring air. Radiant heaters provide efficient and
economical protection against cold draughts caused by
windows by heating the window’s surface. The colder the
window, the more radiant heat it will draw. The radiated
heat ”automatically” migrates to where it is most needed,
which facilitates the creation of a comfortable indoor
climate.
• Bypositioningtheheatersathighleveltheriskofgetting
in contact with the heater is greatly reduced. The heater
is also protected against damage.
• Someradiantheatersareidealforpremiseswithfirerisk
or highly explosive environments (see radiant heaters
ComfortPanelSZandSZR).
• Easyandflexibleinstallation.
• Requiresaminimumofmaintenance.
Space
• Byputtingtheheaterontheceiling,valuablewalland
floor space is saved.
Comfort
• Usingtheradiationprincipleairisnotheateddirectly.
This results in a soft, draught-free, comfortable indoor
climate and an even temperature.
• Doesnotcauseanyairmovement,astraditional
heating systems often do. Reducing the spread of dust,
bacteria or odours improves the quality of the indoor
environment.
Discreet
• Thesystemiscompletelysilent.
• Mountingontheceilingorrecessedinafalseceiling
gives a discreet heating.
32
Choose the right radiant heater
Radiant heaters are available in various designs – it
is primarily the installation height, the surrounding
environment and the type of heating wanted (see previous
page)thatdeterminethechoiceofproduct.
Our radiant heaters are divided into three main
application areas: "Offices, shops and public premises",
"Industry and large premises" and "Outdoors" but most of
them can be used in several application areas as you can
see in below table.
Comfort
Radiant heaters
To acheive good comfort, it is essential to choose the right
type of radiant heater.
An infrared heater equipped with halogen lamps at
approx. 2000 °C provides intense, short-wave radiation. It
is well-suited to outdoor use or in rooms with high ceilings.
For a similar but softer heat an infrared heater with tube
elements at approx. 750 °C can be used. The heat emitted
from these radiant heaters can be compared to the radiant
heat felt from an open fireplace.
A Thermocassette with a large element surface and a
surface temperature of approx. 100 °C, provides longwave heat radiation, giving comfortable heating and good
dispersioninroomsofnormalheight(2,7m).
In a building with high demands on comfort, a larger
number of heaters with low output should be used instead
of fewer heaters with high output.
When zone- or spot heating an area, the heaters should
be placed so that the heat comes from at least two
directions. This is especially important when the heaters
are mounted at lower heights.
Belowtableandtheexamplesonthefollowingpageswill
help you to choose the right radiant heater.
Quick selection guide radiant heaters
Type
Heating
Installation
height
[m]
[W]
[°C]
Offices
Thermoplus
3
3
3
3
3
3
3
3
3
3
2–3
300-900
180
++
+
Radiant aluminium panel
33
<3
300-600
100
++
+
Heating film
34
2,5–4
600-1500
280
++
+
Radiant aluminium panel
34
3–10
800-2200
340
++
Radiant aluminium panel
35
4–15
3600-4500
350
++
Radiant aluminium panel
35
4,5–20
3000-6000
700
++
Infrared heating rod
36
3–5
1500-4500
2200*3
++
+
Halogen lamp
36
2–2,5
500-2000
750
+
++
Infrared heating rod
37
2–3
1200
2200*3
+
++
Halogen lamp
37
1,8–3,5
1000-1500
2200*3
+
++
Halogen lamp
38
3
1,8–3,5
800-3000
1000/1200*3
+
++
Carbon fibre lamp
39
2,5–10
100-580*2
80
Thermocassette
Elztrip EZ100
Elztrip EZ200
Elztrip EZ300
Infrared IR
Infrared IRCF
Infrared CIR
Infrared ELIR
Infrared IH
Carbon Infrared IC
Comfort panel SZR
2
2
Output
Surface
temp.
Application area*1
++
Heating element
Page
Industry Outdoors
+
Radiant steel panel
3–15
50-1900*2
80
++
Radiant steel panel
Comfort panel SZ
*1) Our products are divided into three main application areas: "Offices, shops and public premises", "Industry and large premises" and
"Outdoors" but most products can be used in several application areas.
*2) Per metre, depending on water temperature.
*3) Filament temperature
40
41
33
Radiant heaters
Installation examples for radiant heaters
Frico radiant heaters are available for different kinds of
heating and for different application areas. To facilitate
your choice of product, you will find some typical cases
onthefollowingpages.Moredetailedinformationon
important factors to consider when choosing a radiant
heater is found on the previous pages.
Basic criterias:
1. Type of premises – store, warehouse etc.
2. Type of heating - total heating, zone heating,
cold draught protection
3.Height,installationheight
4.Mounting:wallorceiling
Industry and large premises
Offices, shops and public premises
5. Connection: with electrical heat or water heat
Total heating, cafeteria
1. Type of premises: cafeteria
2. Type of heating: total heating
3.Height:2,80metres
4.Mounting:ceiling
5. Connection: electrical
Recommendation: Thermocassette can be recessed into
a false ceiling. When using Thermocassette for total
heating, the units should be spread out through the
ceiling for example as shown.
Total heating, workshop
1. Type of premises: workshop
2. Type of heating: total heating
3.Height:5metres
4.Mounting:ceiling
5. Connection: with electrical heat
Recommendation:AnumberofEZ300evenly
positioned over the area to be heated creates
comfortable heat.
Zone heating, restaurant terrace
1. Type of premises: restaurant terrace
2. Type of heating: zone heating
3.Height:3metres
4.Mounting:ceiling(abovethetables)
Outdoors
5. Connection: with electrical heat
34
Recommendation:SeveralCIRmountedin
line above the tables ensure the comfort for
all customers in deep terraces.
Radiant heaters - Offices, shops and public premises
Thermoplus
•Thermoplusisavailableinthreeversions:
- Type EC, for dry rooms. Controlled by a separate
thermostat or output control. IP20.
- Type ECVT, for wet rooms. With a built-in cord switch and
thermostat. IP44.
- Type ECV, for wet rooms. Primarily designed for
connection as slave device to ECVT, but can also be
controlled separately using the same methods as for EC.
IP44.
•Bracketsforwallmountingareincluded.Fixturesforceiling
mounting are extra.
•Max.surfacetemperature:180°C.
•Colour:white,RAL9010,NCS0502-B.
•CEcompliant.
Thermoplus EC for dry rooms (IP20)
Type
EC45021
EC45031
EC60021
EC60031
EC75021
EC75031
EC90021
EC90031
Voltage
[V]
230V~
400V~
230V~
400V~
230V~
400V~
230V~
400V~
3
Heat output
[W]
450
450
600
600
750
750
900
900
LxHxD
[mm]
1076x100x90
1076x100x90
1505x100x90
1505x100x90
1810x100x90
1810x100x90
2140x100x90
2140x100x90
Weight
[kg]
2,6
2,6
3,7
3,7
4,4
4,4
4,8
4,8
Radi an t h e at e r s
Thermoplus is mounted above windows
and gives an effecient protection against
cold draught. The slim shape also makes it
2-3m
suitable for heating areas with limited space,
like for example bathrooms. Thermoplus can
furthermore be a cost-effective and flexible
alternative to floor heating.
Thermoplus is covered with white enamel
which makes it discreet and schratch-resistant. The slim shape
makes it practically invisible when mounted in the celing
angle.
Thermoplus ECVT for wet rooms, with built-in switch and
thermostat (IP44) 3
Type
ECVT30021
ECVT55021
ECVT55031
ECVT70021
ECVT70031
Voltage
[V]
230V~
230V~
400V~
230V~
400V~
Heat output
[W]
300
550
550
700
700
LxHxD
[mm]
870x100x90
1505x100x90
1505x100x90
1810x100x90
1810x100x90
Weight
[kg]
2,6
4,3
4,3
5,0
5,0
Thermoplus ECV slave unit to ECVT, for wet rooms (IP44)
Type
ECV30021
ECV55021
ECV55031
ECV70021
ECV70031
Voltage
[V]
230V~
230V~
400V~
230V~
400V~
Heat output
[W]
300
550
550
700
700
LxHxD
[mm]
870x100x90
1505x100x90
1505x100x90
1810x100x90
1810x100x90
3
Weight
[kg]
2,3
4,0
4,0
4,7
4,7
Accessories - Thermoplus
Type
Description
ERP
Electric heating control, master, IP20
ERPS
Electric heating control, slave, IP20
T10
Room thermostat, IP30
TKS16
Room thermostat with knob and 1-pole main switch, IP30
TD10
Room thermostat with digital display, IP30
KRT1900
Room thermostat, IP55
TF1
Fixtures for ceiling mounting (2 pcs)
OS1
Protection net 1070 mm
OS2
Protection net 1500 mm
For controls, see pages 44 and 62-63.
Min. distances EC [mm]
Ceiling
Wall / long side of the unit (EC)
Flammable material/ front side (EC)
Flammable material/ lower side (EC)
Floor
A
B
C
D
E
60
25
90
25
1800
35
Radiant heaters - Offices, shops and public premises
Thermocassette HP
Elztrip EZ100
Thermocassette is intended for discreet heating
in offices, bathrooms, schools etc. Designed
for either surface or recessed mounting it
<3m
is well suited for total heating as well as for
spot heating of for example a reception desk.
Mountedinafalseceilingitiswellprotected
against damage and can easily be moved if
necessary (model with cable and plug).
Recessedmountingmaketheheateranintegralpartofthe
ceiling.
EZ100isintendedfortotalandsupplementary
heating as well as protection against cold
draughts from windows in environments such as
offices, shops, restaurants etc.
EZ100isasinglepanelradiantheaterwith
clean and simple design that blends well with
electrical fittings.
•Thermocassetteisavailableintwoversions:
- HP300/600, for false ceiling systems. IP20.
- HP305/605, standard model with brackets, approved for
rooms where there is risk of fire and recommended for use
inagriculturalbuildings.IP55.
•Thelowsurfacetemperature(max.100°C)makes
Thermocassette well suited for low ceiling heights. There is
no risk of burns to the person(s) in this vicinity.
•Max.surfacetemperature:100°C.
•Colour:white,RAL9016,NCS0500.
•ApprovedbySEMKOandCEcompliant.
Type
HP300
HP600
Voltage
[V]
230V~
230V~
Heat output
[W]
300
600
LxHxD
[mm]
593x30x593
593x30x1193
Weight
[kg]
5,4
10,3
Thermocassette HP with mounting brackets and cable (IP55)
Type
HP305
HP605
Voltage
[V]
230V~
230V~
Heat output
[W]
300
600
LxHxD
[mm]
593x30x593
593x30x1193
•Surfacestructureforbestefficiency.
•Theheatersareapprovedforserialconnection.
•Fixturesforeasymountingontheceilingareincluded.
•Bracketforwallmounting(EZMVK)isavailableasan
accessory.
•Max.surfacetemperature:280°C.
•Colour:white,RAL9010,NCS0502-B.
•ApprovedbySEMKOandCEcompliant.
Elztrip EZ100 (IP44)
Type
EZ106
EZ111
EZ115
Thermocassette HP for false ceilings, with cable and plug
(IP20) 3
3
Weight
[kg]
5,8
10,7
3
Voltage
[V]
230V~
230V~
230V~
Heat output
[W]
600
1050
1500
Type
Min. distances HP [mm]
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
36
80
50
50
500
1800
80
50
500
1800
Weight
[kg]
3,7
5,4
7,8
Description
ERP
Electric heating control, master, IP20
ERPS
Electric heating control, slave, IP20
CIRT
Stepless output control with timer, IP44
T10
Room thermostat, IP30
TKS16
Room thermostat with knob and 1-pole main switch, IP30
TD10
Room thermostat with digital display, IP30
KRT1900
Room thermostat, IP55
EZMVK
Wall mounting bracket
For controls, see pages 44 and 62-63.
Description
ERP
Electric heating control, master, IP20
ERPS
Electric heating control, slave, IP20
T10
Room thermostat, IP30
TKS16
Room thermostat with knob and 1-pole main switch, IP30
TD10
Room thermostat with digital display, IP30
KRT1900
Room thermostat, IP55
74701
Wire mounting kit
For controls, see pages 44 and 62-63.
LxHxD
[mm]
1000x50x150
1500x50x150
2000x50x150
Accessories - EZ100
Accessories - Thermocassette
Type
2,5 - 4 m
Min. distances EZ100 [mm]
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
A
B
C
D
E
50
50
50
500
1800
Elztrip EZ200
Elztrip EZ300
EZ200 is intended for total and supplementary
heating as well as protection against cold
draughts from windows in environments such
as, department stores, assembly halls, industrial
premises etc.
EZ200 is a double panel radiant heater with
clean and simple design that blends well with
electrical fittings.
EZ300 is intended for total and supplementary
heating in industrial environments such as
warehouses, workshops etc.
EZ300 is a triple panel radiant heater with
discreet and robust design that blends well with
electrical fittings.
3 - 10 m
Type
EZ208
EZ212
EZ217
EZ222
EZ20831
EZ21231
EZ21731
EZ22231
Elztrip EZ300 (IP44)
3
Voltage
[V]
230V~
230V~
230V~
230V~
400V2~
400V2~
400V2~
400V2~
Heat output
[W]
800
1200
1700
2200
800
1200
1700
2200
LxHxD
[mm]
683x64x282
923x64x282
1221x64x282
1520x64x282
683x64x282
923x64x282
1221x64x282
1520x64x282
Weight
[kg]
4,9
6,8
8,8
10,7
4,9
6,8
8,8
10,7
Accessories - EZ200
Type
4 - 15 m
•Surfacestructureforbestefficiency.
•Theheatersareapprovedforserialconnection.
•Fixturesforeasymountingontheceilingareincluded.
•Max.surfacetemperature:350°C.
•Colour:Casingofgreyalu-zinccoatedsteelpanelswithhigh
corrosion resistance. Heating panel of naturally anodised
aluminium.
•ApprovedbySEMKOandCEcompliant.
•Surfacestructureforbestefficiency.
•Theheatersareapprovedforserialconnection.
•Fixturesforeasymountingontheceilingareincluded.
•Max.surfacetemperature:340°C.
•Colour:white,RAL9016,NCS0500.
•ApprovedbySEMKOandCEcompliant.
Elztrip EZ200 (IP44)
Radi an t h e at e r s
Radiant heaters - Industry and large premises
Description
Type
EZ336
EZ345
3
Voltage
[V]
230V3~/400V3N~
230V3~/400V3N~
Heat output
[W]
3600
4500
LxHxD
[mm]
1670x63x420
2030x63x420
Weight
[kg]
20
24
Accessories - EZ300
Type
Description
S123
Manual switch for 1-2-3 steps, IP42
T10
Room thermostat, IP30
TK10
Room thermostat with knob, IP30
KRT1900
Room thermostat, IP55
CBT
Electronic timer, IP44
For controls, see pages 44 and 62-63.
ERP
Electric heating control, master, IP20
ERPS
Electric heating control, slave, IP20
CIRT
Stepless output control with timer, IP44
T10
Room thermostat, IP30
TKS16
Room thermostat with knob and 1-pole main switch, IP30
TD10
Room thermostat with digital display, IP30
KRT1900
Room thermostat, IP55
For controls, see pages 44 and 62-63.
Min. distances EZ200 [mm]
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
A
B
C
D
E
Min. distances EZ300 [mm]
80
150
150
600
1800
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
A
B
C
D
E
115
250
250
700
1800
37
Radiant heaters - Industry and large premises
Industrial infrared heater IR
Halogen infrared heater IRCF
IRissuitabefortotalorsupplementaryheating
of premises with large volume and high ceilings.
It can also be used outdoors for example on
sport arena stands or to keep loading bays dry
and frostless.
IRhasarobustindustrialdesign.
IRCFisespeciallydesignedforspotheating
of premises with large air volumes, such as
churches, aircraft hangars and marquees. With
itshighefficiencyandcompactsizeitisperfect
for many difficult applications.
IRCFhasadiscreetandcompactdesign.
Equipped with one to three halogen lamps and
with glossy finished reflectors.
4,5 - 20m
•Reflectorsofshinyanodisedaluminiumfor
optimal heat distribution.
•Themountinghingesallowtheheatertobeangledinfive
different positions.
•Max.surfacetemperature:700°C.
•Colour:Casingofgreyalu-zinccoatedsteelpanelswithhigh
corrosion resistance.
•ApprovedbySEMKOandCEcompliant.
Industrial infrared heater IR (IP44)
3
Voltage
Heat output LxHxD
Weight
[V]
[W]
[mm]
[kg]
IR3000
400V3N~*
3000
1125x83x358
9,0
IR4500
400V3N~*
4500
1500x83x358
11,1
IR6000
400V3N~*
6000
1875x83x358
13,2
*) Can be connected without neutral, but then without output steps. With
neutral, one elements at a time can be connected.
3 - 10 m
•Equippedwithonetothreehalogenlampsandwithglossy
finished reflectors.
•Easymountingwithmountingbracketonthewallorceiling.
The heater can be angled.
•Protectiongrilleavailableasanaccessory.
•Max.elementtemperature:2200°C.
•Colour:grey,RAL9006.
•CEcompliant.
Type
Accessories - Industrial infrared heater IR
Type
Description
Type
Min. distances IR [mm]
3
Voltage
[V]
230V~
230V~
230V~/400V3~
IRCF1500
IRCF3000
IRCF4500
Heat output
[W]
1500
3000
4500
HxWxD
[mm]
490x230x140
490x375x140
490x515x140
Description
Manual switch for 1-2-3 steps, IP42
Electronic timer, IP44
Electronic thermostat with concealed knob
Electronic thermostat with visible knob
Capillary room thermostat, IP55
Extra lamp
Protection grille for IRCF1500. IRCF3000 require 2 pcs,
IRCF4500 require 3 pcs.
For controls, see pages 44 and 62-63.
S123
CBT
T10
TK10
KRT1900
LIRCF
IRCG1
Min. distances IRCF [mm]
A
B
C
D
E
400
400
400
700
2300
A
A
B
B
C
C
Ceiling
Wall
Floor
38
Weight
[kg]
2,0
2,5
3,0
Accessories - IRCF
Type
S123
Manual switch for 1-2-3 steps, IP42
T10
Room thermostat, IP30
TK10
Room thermostat with knob, IP30
KRT1900
Room thermostat, IP55
CBT
Electronic timer, IP44
IRG3000
Protection grille IR3000
IRG4500
Protection grille IR4500
IRG6000
Protection grille IR6000
For controls, see pages 44 and 62-63.
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
Infrared heater IRCF (IP20)
A
B
C
500
50
2300
Ceiling
Wall
Floor
A
B
C
180
500
2300
Infrared heater CIR
Halogen infrared heater ELIR
CIRprovidecomfortallyeararoundon
terraces, balconies and open-air restaurants.
CIRcanalsobeusedforspotheatingin
workshopsandwarehouses.Requiresno
protection against bad weather and has fiveyear corrosion warranty.
CIRisdiscreetwithitsslimdesignand
silent, invisible operation and needs little
space to fit in.
ELIRgivesanintenseheatsuitable
for all outdoor applications and rough
industrialpremises.WhileELIRislight,
2-3 m
stable and portable it is also well suited
for temporary heating on building sites
etc. With its concentrated heat it is a good
complement to dehumidifiers for drying in
areas damaged by water. High protection
class(IP65)makesitpossibletoinstallthe
heater in almost any environment.
ELIRhasathoroughdesigninacompactformat.Simple,
robustandlight(1kg).ELIRhasnoprotectiveglasswhich
means10–15%higherefficiencycomparedtoaheaterwith
glass with the same protection class.
2 - 2,5 m
•InfraredheaterCIRisavailableintwoversions:
- CIR100withoutputsbetween500and2000W.
- CIR200 with the same outputs and built-in switch.
•Reflectorsofhigh-glosspolishedaluminiumwithmaximum
resistance against corrosion.
•Greyterminalboxesofheatandweatherresistant
polycarbonate.
•Adjustablemountingbracketsforeasymountingonthewall
or ceiling.
•Max.surfacetemperature:750°C.
•Colour:white,RAL9002,NCS1502-Y.
•ApprovedbySEMKOandCEcompliant.
Infrared heater CIR without built-in switch (IP24)
Type
CIR10521
CIR11021
CIR11031
CIR11521
CIR11531
CIR12021
CIR12031
Voltage
[V]
230V~
230V~
400V2~
230V~
400V2~
230V~
400V2~
Heat output
[W]
500
1000
1000
1500
1500
2000
2000
Infrared heater CIR with built-in switch (IP24)
Type
CIR20521
CIR21021
CIR21031
CIR21531
CIR22031
Voltage
[V]
230V~
230V~
400V2~
400V2~
400V2~
Heat output
[W]
500
1000
1000
1500
2000
3
LxHxD
[mm]
710x44x94
1250x44x94
1250x44x94
1755x44x94
1755x44x94
2180x44x94
2180x44x94
Weight
[kg]
1,5
2,2
2,2
3,0
3,0
3,7
3,7
•Allpartsareanti-corrosive.
•Casing/reflectorsofhigh-glosspolishedaluminiumwith
maximum resistance against corrosion.
•ELIRismountedonthewallwiththeaccompanying
mounting bracket or suspended from the ceiling. It can also
bemountedonastandforportableuse.Suspensiondetails
and stand are extra.
•Greyterminalboxesofheatandweatherresistantplastic.
Colour:RAL7035.
•Max.surfacetemperature:2200°C.
•CEcompliant.
Infrared heater ELIR (IP65)
Type
ELIR12
Voltage
[V]
230V~
3
Heat output
[W]
1200
LxHxD
[mm]
712x112x83
Weight
[kg]
1,0
Accessories - ELIR
3
LxHxD
[cm]
710x44x94
1250x44x94
1250x44x94
1755x44x94
2180x44x94
Radi an t h e at e r s
Radiant heaters - Outdoors
Weight
[kg]
1,5
2,2
2,2
3,0
3,7
Type
Description
ELIRC
Chain for ceiling mounting
ELIRS
Floor stand (tripod) with bracket for ELIR included
ELIRB
Universal bracket when using any floor stand (i.e. tripod)
IREL12
Extra lamp
CBT
Electronic timer, IP44
For controls, see pages 44 and 62-63.
Accessories - CIR
Type
Description
CIRT
Stepless output control with timer, IP44
CBT
Electronic timer, IP44
For controls, see pages 44 and 62-63.
Min. distances ELIR [mm]
Min. distances CIR [mm]
150
150
300
700
1800
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
A
B
C
D
E
400
600
600
1000
1800
39
Radiant heaters - Outdoors
Halogen infrared heater IH
Accessories - IH
Halogen infrared heater IH is the perfect
choice for exposed outdoor environments
where design is important, for example,
1,8 - 3,5 m
balconies, pavement cafés, etc. IH can also be
used as local heating in large premises such as
churches, industries and warehouses.
IH is easy to position thanks to its compact
design. The discreet and appealing look makes
it suitable for outdoor environments with design demands.
•IHisavailableintwoversions:
- IHWprovideswideheatdistribution(60°),recommended
installationheight1.8–2.5m.
- IHFprovidesdirectedheatdistribution(40°),
recommendedinstallationheight2.3–3.5m.
•IHconsistsofahalogenlampwithaveryhighintensityanda
highly-polished reflector for optimum heat distribution.
•Gives10-15%higherefficiencythanaglassfrontedheaterof
the same enclosure.
•Bracketforwallmounting.Canalsobesuspendedfrom
theceilingormountedone.g.aparasolorapost.Other
mounting alternatives are available as accessories.
•Max.elementtemperature:2200°C.
•Colour:grey,RAL9006.
•ApprovedbySEMKOandCEcompliant.
Infrared heater IHW with wide heat distribution (IPX4)
Type
IHW10
IHW15
Voltage
[V]
230V~
230V~
Heat output
[W]
1000
1500
LxHxD
[mm]
500x77x169
500x77x169
IHF10
IHF15
Voltage
[V]
230V~
230V~
Heat output
[W]
1000
1500
Description
CBT
IHUB
IHXH
IHXL
IHT
IHTW
Electronic timer, IP44
Universal bracket for IH
Drooping extension bracket for high level mounting
Arching extension bracket for low level mounting
Triple bracket
Set of three bright galvanized wires for easy hanging
of IHT
Post for freestanding installation
Halogen lamp 1000W
Halogen lamp 1500W
IHP
IHL1000
IHL1500
IHXH
IHXL
3
Weight
[kg]
1,9
1,9
Infrared heater IHF with directed heat distribution (IPX4)
Type
Type
LxHxD
[mm]
500x77x169
500x77x169
3
Weight
[kg]
1,9
1,9
IHUB
Min. distances IH [mm]
A
IHT + IHTW
B
C
Ceiling
Flammable material
Floor
40
A
B
C
200
1000
1800
IHP + IHT
Radiant heaters - Outdoors
ICW
ICWP
ICSR
ICB
ICS
Carbon infrared heater IC
Carbon infrared heater IC produces gentle
and direct heat that is ideal for indoors and
conservatories as well as out on terrace. ICW
gives a comfortable heat at close range and
1,8 - 3,5 m
alsowiderheatdistribution.ICShasmore
directed heat distribution and is designed
forinstallationhigherup.ICBisespecially
intended for bathrooms.
The design and heating technology makes
itpossibletoplaceICverticallyaswellashorizontally.
The different accessories also allow a range of installation
possibilities.
ICW with wide heat distribution
•SeveralversionsofICareavailable:
- ICW provides wide heat distribution, recommended
installationheight1.8-2.5m.
- ICSR can be controlled by remote control or by control
panel on the heater. It provides directed heat distribution,
recommendedinstallationheight1.8-3.5m.Models
withoutcontrolpanel/remotecontrolareavailableunder
the designation ICS.
- ICWPisportable(with1.5mhighstand)andproduces
wide heat distribution.
- ICB is intended for bathrooms.
•Carbonfibrelampthatproducesgentleandfastradiantheat.
Servicelife:10,000hrs
•Flexiblemountingbracketforhorizontalorvertical
installation,directonwallorceiling.Severalmounting
options are available as accessories, such as wall and ceiling
mounting on aluminium rail or with a flexible universal
bracket, installation on stand or awning.
•Equippedwitha1.9metrelongcordwithplugforconnection
to an earthed mains socket.
•Integratedoutputselectorandthermostat.
•Max.elementtemperature:1200°C+/-100°C.
ICB:1000°C+/-100°C.
•Protectionclass,horizontalinstallation:IP44,vertical
installation IP42.
•Colourcasing:grey(ICW(P))silver(ICS(R)ICB).
Plasticends,RAL7022(ICW(P))RAL7037(ICS(R),ICB).
Chromed steel grille.
•ApprovedbyTÜVandCEcompliant.
ICS with directed heat distribution
ICW15
ICW20
ICW30
Voltage
[V]
230V~
230V~
230V~
Type
ICSR20
ICSR30
Type
ICS15*
ICS20*
ICS30*
Voltage
[V]
230V~
230V~
Heat output
[W]
2000
3000
Voltage
[V]
230V~
230V~
230V~
Heat output
[W]
1500
2000
3000
LxHxW
[mm]
854x209x238
1070x209x238
Type
Voltage
Heat output
ICWP17
[V]
230V~
[W]
1750
ICB for bathrooms
3
Weight
[kg]
6,2
7,1
3
LxHxW
[mm]
746x209x238
854x209x238
1070x209x238
ICWP, portable with stand, wide heat distribution
LxHxW
heater
[mm]
837x228x231
Weight
[kg]
5,0
5,2
6,3
3
Height
stand
[mm]
1500
Weight
[kg]
10
3
Type
Voltage
[V]
ICB8*
230V~
ICB10
230V~
ICB12*
230V~
*) Not kept in stock.
Heat output
[W]
800
1000
1200
LxHxW
[mm]
729x228x231
729x228x231
729x228x231
Weight
[kg]
4,7
4,7
4,7
Accessories - carbon infrared heater IC
Type
Description
CBT
ICPP20
ICPB
ICAP15
ICAP20
ICUB
ICAB
ICL1500
ICL1000
ICL875
ICL750
ICL500
Electronic timer, IP44
Post, L = 2 m
Stand foot
Aluminium rail L = 1,5 m
Aluminium rail L = 2 m
Universal bracket
Awning bracket
Extra lamp 1500W
Extra lamp 1000W
Extra lamp 875W
Extra lamp 750W
Extra lamp 500W
Min. distances ICWP [mm]
Can be rotated to the vertical
position.
Vertical mounting
IC 1-2 kW: 300
IC 3 kW: 500
Weight
[kg]
5,0
5,2
6,3
100
400
(ICB: 300)
500
(ICB: 300)
2200
1800
(ICB: 400)
1800
(ICB: 400)
500
(ICB: 300)
L=1500
400
LxHxW
[mm]
783x228x231
891x228x231
1107x228x231
ICSR with remote control and directed heat distribution
Min. distances ICW/ICSR/ICS/ICB [mm]
Horizontal mounting
3
Heat output
[W]
1500
2000
3000
Radi an t h e at e r s
Type
400
41
Radiant heaters- water heated
Comfort Panel SZR
ComfortPanelSZRisusedforwatersupplied
heating/coolingsystems.Itcanbemounted
free hanging or integrated in false ceilings and
2,5 - 10 m
perfectly suits in fine environments such as
offices, shops, etc.
Discreet flat satin finished surface that
matchesmostfalseceilingpaneldesigns.A
perfectsymmetricanbecreatedwithheating/coolingpanelsin
combination with non active panels.
•ComfortPanelSZRisavailableinfollowingversions:
- SZRxxxP for recessed mounting in false ceilings.
- SZRxxxM for free hanging mounting.
•Thepanelsareavailableinfivelengthswiththreedifferent
pipe settings. The lengths can be combined to a total panel
lengthdesired.Nonactivepanelsareavailable.
•CompliestoEN14037whichisbasedontheEUConstruction
ProductDirectives89/106/CEE.EN14037iscompulsoryfora
CE mark for water heated radiant heaters.
•Maxworkingpressure:4bar.
•Maxwatertemperature:90°C
•Colour:white,RAL9016,NCS0500.
•CEcompliant.
Insulation 30 mm (included, not
mounted)
Comfort Panel SZR for recessed mounting
Type*1
SZR060P
SZR120P
SZR180P
SZR240P
SZR300P
SZRN60P
SZRN120P
Heat output*2
[W/pcs]
178
355
534
713
893
Non active
Non active
Weight
[kg]
7
14
21
28
35
4
8
LxHxW
[mm]
595x35x595
1195x35x595
1795x35x595
2395x35x595
2995x35x595
595x35x595
1195x35x595
Suspension
Insulation holding
strip
Comfort Panel SZR for free hanging mounting
Type*1
Heat output*2
Weight
LxHxW
[W/pcs]
[kg]
[mm]
SZR060M
178
7
595x35x595
SZR120M
355
14
1234x35x610
SZR180M
534
21
1858x35x610
SZR240M
713
28
2482x35x610
SZR300M
893
35
3106x35x610
SZRN60M
Non active
4
610x35x610
SZRN120M
Non active
8
1234x35x610
*¹) The panels are available with three different pipe settings.
*2) Applicable at water temperature 80/60 °C, air temperature +20 °C.
Accessories - Comfort Panel SZR
Type
Description
RTI2
Room thermostat, IP44
T10
Room thermostat, IP30
TVV20/25
2-way control valve, DN 20/25 mm
SD20
Actuator
TRV20/25
3-way control valve, DN 20/25 mm
Suspension accessories are priced on request.
A Comfort Panel handbook with detailed information is available at
www.frico.se. Further information can also be obtained by contacting
Frico.
42
Recessed mounting in false ceiling
Radiant heaters- water heated
Comfort Panel SZ
3 - 15 m
Radi an t h e at e r s
ComfortPanelSZistheidealsystemsolution
for water supplied heating of larger buildings
such as industrial buildings, commercial
buildingsandsportscentres.ComfortPanelSZ
is suitable for both high and low installation,
and extremely high installations are possible
withpressurizedhotwater.
•CompliestoEN14037whichisbasedontheEUConstruction
ProductDirectives89/106/CEE.EN14037iscompulsoryfora
CE mark for water heated radiant heaters.
•Forceilingmountinginpanellengthsof4metersupto120
meters.
•Maxworkingpressure:10bar(specialversion:16bar).
•Maxwatertemperature:120°C(specialversion:180°C).
•Colour:white,RAL9016,NCS0500orlightgrey,RAL9002,
NCS1502-Y.Othercoloursavailableonrequest.
•CEcompliant.
Comfort Panel SZ max 120 °C
2
Type
Heat output* Weight
Width
[W/m]
[kg/m]
[mm]
SZ23
162
4
300
SZ26
289
8
600
SZ29
406
12
900
SZ212
543
16
1200
SZ33
194
6
300
SZ36
345
12
600
SZ39
501
18
900
SZ312
639
24
1200
*) Applicable at water temperature 80/60 °C, air temperature +15 °C.
Comfort Panel SZ special max 180 °C
2
Type
Heat output* Weight
Width
[W/m]
[kg/m]
[mm]
SZ23SP
267
5
300
SZ26SP
477
10
600
SZ29SP
667
15
900
SZ212SP
870
20
1200
SZ33SP
324
7
300
SZ36SP
574
14
600
SZ39SP
790
21
900
SZ312SP
1005
28
1200
*) Applicable at water temperature 130/70 °C, air temperature +15 °C.
Accessories - Comfort Panel SZ
Type
Description
RTI2
T10
TVV20/25
SD20
TRV20/25
Room thermostat, IP44
Room thermostat, IP30
2-way control valve, DN 20/25 mm
Actuator
3-way control valve, DN 20/25 mm
1. Threaded male connection (Ø 1/2” - 3/4” - 1” - 1.1/4”)
2. Connection for drain valve Ø 3/8”
3. Connection for air vent. valve Ø 3/8”
4. First or end header
5. Steel pipe Ø 1/2”
6. Radiant panel
7. Suspension bracket
8. Insulation
9. Side edging strip
10. Insulation retaining clip
11. Anti-convective side skirts (accessory)
12. Skirt hook
13. Pipe ends adapted for press fitting or compression fitting
or belled end for welding
14. Make-up joint
15. Make-up joint between panel and header (accessory)
A Comfort Panel handbook with detailed information is available at
www.frico.se. Further information can also be obtained by contacting Frico.
43
Radiant heaters - Controls
ERP, electric heating control
CIRT, stepless output control with timer
Steplesspulsecontrolintendedforsinglephase(3600W/230V)
ortwophase(6000W/400V2~)electricheaters.Cannotcontrol
3phaseloads.Pulsetime60secs.Triaccontrol(quietcontrol).
Integrated temperature sensor. External sensors available as
anaccessory.Savereductionfunctionviaexternalconnection
timer(1–10degrees).Forlargerpoweroutputsaslaveunit
(ERPS)canbeconnected.EachERPScanhandlethesame
powerasERP.
Steplessoutputcontrolwithtimer,primarilyintendedfor
infrared heaters and other radiant heaters. Intended for single
phase(3600W/230V~)ortwophase(6000W/400V2~)electric
heaters.Especiallysuitedforspotamdzoneheating.Theheat
contributionisregulatedforbestcomfort(25-100%).The
built-intimercanbesetfor0.5to4or4to24hours.High
protection class (IP44).
Electric heating control ERP (IP20)
Output control CIRT (IP44)
Type
ERP
ERPS
Voltage
[V]
230/400V~
230/400V~
HxWxD
[mm]
153x93x40
153x93x40
Type
CIRT
Voltage
[V]
230/400V2~
HxWxD
[mm]
155x87x43
Accessories ERP
Type
Description
ERPRG
ERPGG
Room sensor ERP
Floor/duct sensor ERP
S123, manual switch for 1-2-3 steps
Controlstheoutputinthreesteps0-1/3-2/3-3/3.
Manual switch S123 (IP44)
Type
S123
44
Voltage
[V]
230/400V3~
HxWxD
[mm]
72x64x46
Fan heaters
For decades Frico has been the world leader in fan
heater design. Today we have a complete range of
high quality equipment modelled on the demanding
climate of Scandinavia. Frico’s worldwide distribution
network encounters many different environmental
conditions, such as storage rooms, pump rooms,
building sites, mines, sports centres, shops, drying
rooms, stables, boats, etc.
We are proud of the worldwide acclaim we have
gained through our line of fan heaters. They are
known as reliable and long-lasting products. The
heaters are also robust and will withstand rough
treatment in aggressive environments, at the same
time having the lowest sound level on the market.
Exceptionally quiet
One of the most important tasks in our product development,
is the construction of low noise fan heaters.
At our plant in Skinnskatteberg, Sweden, you will find one
of the most sophisticated air and sound laboratories in Europe,
staffed by highly skilled technicians making it possible to
manufacture products of the finest quality.
Lots of power, small investment
Fan heaters
Compared to other heating systems, the investment cost for
fan heaters is low. Frico fan heaters give you lots of power for
the money.
Compact and robust
Frico fan heaters are compact and light. Therefore they are
easy to carry or can easily be mounted on the wall.
The heaters are also very robust and withstand heavy
handling in aggressive environments.
Electricity or water?
Frico fan heaters are available for electrical or water heating you have the choice!
Heating and ventilation
A great advantage of fan heaters is the option of combining
heating and ventilation. Mixing cabinets for stationary fan
heaters create economic heating and ventilation, by mixing the
return air with fresh air.
45
Fan heaters - electrically heated
Door heater PA1006
Fan heater K21
PA1006isacompactdoorheaterwhichheatstheincomingair
andgivesincreasedcomfortontheinside.Whenwallmounted,
theunitcanactasastationaryfanheater.
Thedoorheaterhasaclean,straightforwarddesign.Asthe
air inlet is placed on top of the unit the front of the unit is kept
free of dirt and dust.
K21 is a compact and safe fan heater designed for portable use.
Ideal for heating small areas, for example, garages, caravans,
awnings, weekend cottages, offices, patios, etc.
K21 fan heater is small and compact in white metal finish
and is equipped with a solid handle.
•Compactandeasytoposition.
•Lowsoundlevel.
•Theunitiseasilyangledonthebracket,whichisusedfor
both wall and ceiling mounting.
•Integratedcontrol.
•Designedforpermanentinstallationandisconnectedvia
cable without plug.
•Colour:white,RAL9016,NCS0500.
•CEcompliant.
•Self-regulatingceramicPTCelementthatcannotbe
overheated.
•Intensiveandconcentratedheatemission.Theairisheated
toapprox.65°CwhenitpassesthroughK21.
•Equippedwith2metrelongcordwithplugforconnectionto
an earthed outlet socket.
•Thermostat(+5–+35°C)andoutputselector(0/1/2kW).
•DimensionsHxBxD:220x160x200mm.
•Colour:white,RAL9016,NCS0500.
•ApprovedbySEMKOandCEcompliant.
Door heater PA1006E03 (IP20)
Fan heater K21 (IP21)
Type
3
Voltage Output Airflow Sound HxWxD
Weight
steps
level*
[V]
[kW]
[m³/h] [dB(A)] [mm]
[kg]
PA1006E03 230V~
0/1.5/3 230
44
153x164x650 5,3
*) Conditions for sound level measurements, see page 67.
46
Type
3
Voltage Output Airflow Sound
[V]
steps
level*
[kW]
[m³/h]
[dB(A]
K21
230V~
0/1/2
90
43
*) Conditions: Distance to unit 5 metres.
HxWxD
Weight
[mm]
220x160x200
[kg]
2,5
Fan heaters - electrically heated
Fan heater Tiger
•TheTigerfanheaterisavailableinthefollowingdesigns:
-P21 and P31 have a 1.8 m cord with plug for connection to
earthedoutletsockets.Canbehungonthewall.
-P33, P53 and P93havea1.8mcablewithCEE-plug.
230V-outletsocket(typeE)attherear.Canbehungonthe
wall.
-P153hasa1.8mcablewithCEE-plug.Canbehungonthe
wall.
-P203, P303 and P305 are supplied with a 1.8 m cable
withoutaplug.P305canbeconnectedto440V3~and
500V3~.
•Lowsoundlevel.
•Integratedthermostatwithsettingrange+5–+35°Cand
output selector.
•Colour:red,RAL3020,NCS1090-Y80R.
•CEcompliant.
Conditions for sound level measurements, see page 67.
Fan heater Tiger 2–9 kW (IP44)
Type
3
Voltage
Output Airflow Sound HxWxD
Weight
steps
level
[V]
[kW]
[m³/h] [dB(A)] [mm]
[kg]
P21
230V~
0/2
280
41
450x290x390 5,7
P31
230V~
0/2/3
280
41
450x290x390 6,0
P51
230V~
0/3,3/5 480
41
450x290x390 6,4
P33
400V3N~* 0/1,5/3 280
41
450x290x390 6,3
P53
400V3N~* 0/2,5/5 480
40
450x290x390 6,7
P93
400V3N~* 0/4,5/9 720
44
530x350x480 10
*) Also available without neutral and are then called P33-0, P53-0 and
P93-0. These models do not have a 230 V~ socket on the back.
Fan heater Tiger 15 kW (IP44)
Type
Voltage
P153
[V]
400V3~
Output
steps
[kW]
0/7,5/15
3
Airflow Sound
level
[m³/h] [dB(A)]
1120
47
Fan heater Tiger 20 and 30 kW (IP44)
Type
HxWxD
Weight
[mm]
510x410x530
[kg]
16
3
Voltage Output
Airflow
Sound HxWxD
steps
level
[V]
[kW]
[m³/h]
[dB(A)] [mm]
P203
400V3~ 0/10/20
1900/2600 60
590x630x600
P303
400V3~ 0/10/20/30 1900/2600 52
590x630x600
P3053* 440V3~ 0/7,5/15/23 1900/2600 52
590x630x600
500V3~ 0/10/20/30
*) Can be connected to 440V3~ and 500V3~.
Fan heaters
Tigerisarangeofrobustandcompactfanheatersfor
professionalswithhighdemands.TheTigerfanheateris
portable,modelsupto15kWcanalsobehungonthewall.
Tiger2-9kWareintendedforheatinganddryingareassuch
as garages, workshops and shops.
Tiger15,20and30kWareidealforheatinganddrying
larger premises such as industrial premises and workshops,
where higher outputs are required.
TheTigerfanheaterhasacompactandrobustsheetsteel
designwitharedfinish.Theheavy-dutytubularframeactsas
awell-balancedandergonomiccarryinghandle.Thedesign
protects against impact and vibrations and permits use in
exacting environments.
Weight
[kg]
26
30
30
Accessories - Tiger
Type
Description
LT22406
Wall bracket
47
Fan heaters - electrically heated
Fan heater Cat
Catisarangeofcompactandquietfanheatersforstationary
use.Itisideallysuitedforsmallstockrooms,inagarage,
workshoporshop.Themixingcabinet(accessory)allows
heating and ventilation to be combined, through mixing the
return air and outdoor air.
TheCatfanheaterhasaclassiccleandesigninwhite
enamelled sheet steel. It is small and unobtrusive and with
thateasytoposition.
CMB35 with Cat
•Lowsoundlevel.
•Wallbracketwith10°tiltangleforgoodheatdistribution.
•Integratedthermostatwithsettingrange+5–+35°Cand
outputselector.Externalcontrol,forexample,thermostat
and timer is possible.
•Colour:white,RAL9016,NCS0500.
•CEcompliant.
Fan heater Cat (IP44)
Type
Voltage
3
Output
steps
[kW]
0/1,5/3
Airflow Sound HxWxD
level
[m³/h] [dB(A)] [mm]
280
41
255x335x276
Weight
[V]
[kg)
230V~
6,3
400V3N~
C5
400V3N~ 0/2,5/5
480
40
255x335x276 6,7
C9
400V3N~ 0/4,5/9
720
44
315x405x335 10,2
*) C3 can be connected for 230V~ and 400V3N~. Other models should
not be connected for single phase, 230V~.
C3*
EV300
EV300, output selector
Outputselectorwithoutputsteps0-1/2-1/1.IP44.
CMB35, mixing cabinet
MixingcabinetforC3andC5.Saveenergybymixingthe
outdoorairwiththereturnairinindividuallyselected
proportions.Anouterwallgrille,awalling-inframeandahand
controller are supplied with the mixing cabinet.
TP3/5 and TP9, cover panel for switches
Coverstheswitchesontheheaterandpreventschangesinthe
settings.
Accessories - Cat
Control kits Cat
Built-in control:
Thebuilt-inthermostatcontrolsfanspeedandheat,or
heatonly.Thechoiceismadewiththemodeselector.
Theoutputcanbecontrolledviathebuilt-inoutput
selector(0-1/2-1/1).
External regulation:
- T10/TK10roomthermostats
- EV300,outputselector
- CBT,electronictimer
48
Type
Description
T10
Room thermostat, IP30
TK10
Room thermostat with knob, IP30
TKS16
Room thermostat with knob, 1-pole switch, IP30
KRT1900
Room thermostat, IP55
EV300
Output selector, IP44
CBT
Electronic timer, IP44
KUR
Digital time switch, IP55
CMB35
Mixing cabinet for C3 and C5
TP3/5
Cover panel for switches for C3 and C5
TP9
Cover panel for switches for C9
For controls, see pages 62-63.
Conditions for sound level measurements, see page 67.
Fan heaters - electrically heated
Elektra - C/F/V/H
•TheElektrafanheaterisavailableinfourdesigns:
-Elektra C is intended for corrosive and damp
environments,forexample,car-washhallsandsewage
works.Outercasingofacid-proofsheetsteel.IP65.
-Elektra F has a low element temperature and is approved
foruseincombustibleareas,forexample,joinery
workshopsandagriculturalbuildings.IP65.
-Elektra V is designed to withstand vibrations on ships and
offshoreplatformsandisapprovedbyDetNorskeVeritas.
Alsoavailablefor440V/60Hz.IP44.
-Elektra H is designed for rooms with high temperatures, up
to70°C.IP44.
•Colour:stainlesssteeloutercasing(ElektraChasanacidproofoutercasing).Grilleandbracket:red,RAL3020.
•ApprovedbySEMKOandCEcompliant.ElektraVis
approvedbyDetNorskeVeritas.
Fan heater Elektra C for corrosive and humide environments (IP65)
Type
Voltage
ELC331
ELC633
ELC933
ELC1533
Airflow HxWxD
Weight
[V]
230V~
[m³/h]
400
[mm]
375x300x340
[kg]
13
400V3~
400V3~
400V3~
0/3/6
0/4,5/9
0/7,5/15
1000
1000
1300
445x375x430
445x375x430
445x375x430
20
20
20
Type
Vvoltage
ELF331
ELF633
ELF933
[V]
230V~
400V3~
400V3~
Output
steps
[kW]
0/1,5/3
0/3/6
0/4,5/9
3
Airflow HxWxD
Weight
[m³/h]
400
700
1000
[kg]
13
13
20
[mm]
375x300x340
375x300x340
445x375x430
Fan heater Elektra V for ships and offshore platforms (IP44)
Type
Voltage
ELV331
ELV3333
ELV3344
ELV5333
ELV6344
[V]
230V~
400V3~
400/440V3~
400V3~
400/440V3~
Output
steps
[kW]
0/2/3
0/1,5/3
0/1,8/3,6
0/2,5/5
0/3/6
Weight
[m³/h]
400
400
400
700
700
[kg]
13
13
13
13
13
Fan heater Elektra H for high temperatures (IP44)
Type
Voltage
ELH633
ELH933
[V]
400V3N~
400V3N~
Output
steps
[kW]
0/3/6
0/4,5/9
3
Airflow HxWxD
[mm]
375x300x340
375x300x340
375x300x340
375x300x340
375x300x340
Elektra C / Elektra V
-ELSRT,controlbox,controlsoneunit
-ELSRT4,controlbox,controlsfourunits
Elektra F
-ELS,controlbox,controlsoneunit
Elektra H
-ELRT,roomthermostat
ELSRT
ELSRT4
ELS
ELRT
ELSRT/ELSRT4, control panel
Therequiredoutputandtemperaturecanbesetonthecontrol
panel.Integratedthermostat,+5–+35°C.Usedforexternal
control, for example, when installed high on a wall. ELSRT
controlsonlyoneunit.ELSRT4 can control up to four units.
IP65.
ELS, control panel start/stop
Controlpanelthatstarts/stopsthefan,forexternalcontrol,for
example,wheninstalledhighonawall.Onlyoneunitcanbe
controlledfromonecontrolpanel.IP65.
ELRT, room thermostat
Capillarytubethermostatwithvisibledial.Settingrange
0-+70°C.Max.breakingcurrent:16A.IP44.
Accessories - Elektra
Type
Description
Control box with thermostat for ELC and ELV, start/stop,
175x150x100 mm, IP65
ELSRT4
Control box with thermostat for ELC and ELV, start/stop,
for 4 units, 255x360x110 mm, IP65
ELS
Control box for ELF, start/stop, 105x70x80 mm, IP65
ELRT
Room thermostat for ELH, 175x150x100 mm, IP44
KRT1900
Room thermostat, IP55
For controls, see pages 62-63.
ELSRT
3
Airflow HxWxD
Weight
[m³/h]
1000
1000
[kg]
20
20
[mm]
445x375x430
445x375x430
FanheaterElektraHfeaturesanintegratedthermostat
withtheworkingrange0–+70°C,othermodelsfeaturean
integratedthermostatwiththeworkingrange0–+35°C.The
output can be selected using the output selector on the unit or
on the external control panel.
3
Output
steps
[kW]
0/1,5/3
Fan heater Elektra F for combustible areas (IP65)
Control options
Fan heaters
Elektraisarangeoffanheatersdesignedforuseindemanding
environments.Thedifferentmodelscanbeusedanywhere
from corrosive environments and combustible areas to rooms
with high temperatures as well as onboard ships and offshore
platforms.Elektraismainlydesignedforstationaryuse,yet
can also be used as a portable fan heater.
TheElektrafanheaterhasamoderndesignwithastainless
steeloutercasing,redgrilleandredbrackets.Thebrackets
canberotated,whichmeansElektracanalsobeusedasa
portable fan heater.
49
Fan heaters - electrically heated
Fan heater Panther 6-15
Fan heater Panther 20-30
Panther6-15isarangeofveryquietandefficientfanheaters
forstationaryuse.Theyareintendedforheating,dryingand
ventilationine.g.workshops,sporthalls,shops,assembly
roomsanddryingrooms.Themixingcabinet(accessory)
allows heating and ventilation to be combined, through mixing
the return air and outdoor air.
ThePantherfanheaterhasaclassiccleandesigninwhite
enamelled sheet steel.
Panther20–30isarangeofpowerfulandquietfanheaters
forstationaryuse.Theyareintendedforheating,dryingand
ventilationoflargepremises,forexample,industries.The
mixingcabinet(accessory)allowsheatingandventilationtobe
combined, through mixing the return air and outdoor air.
ThePantherfanheaterhasaclassiccleandesigninwhite
enamelled sheet steel.
•Lowsoundlevel.
•Suppliedwithwallbracketthatmakesitpossibletodirect
the airflow down and to the side.
•Timedelaybetweentheoutputsteps.
•Integratedthermostatwithsettingrange+5–+35°C,
possibilitytoconnectanexternalthermostat.
•ExternalcontrolpanelPP15(orderedseparately)with
master/slavefunction,foruptosixunitsgivesgoodand
simple control.
•Colour:white,RAL9016,NCS0500.
•CEcompliant.
Fan heater Panther 6-15 kW (IP44)
Type
Voltage
Fan heater Panther 20 and 30 kW (IP44)
3
Output Airflow
Sound
steps
level
[V]
[kW]
[m³/h]
[db(A)]
SE06
400V3N~ 0/3/6
900/1300 39/47
SE09
400V3N~ 0/4,5/9 900/1300 39/47
SE12
400V3N~ 0/6/12
900/1300 39/47
SE15
400V3N~ 0/7,5/15 900/1300 39/47
SE135 440V3~
0/5/10
900/1300 39/47
500V3~* 0/7/13,5 900/1300
*) Can be connected to 440V3~ and 500V3~.
HxWxD
Weight
[mm]
520x450x510
520x450x510
520x450x510
520x450x510
520x450x510
520x450x510
[kg]
21
22
22
22
23
Control kits Panther 6-15 kW
Fan speed and thermostat control:
- RTI2orKRT2800,2-steproomthermostats
- PP15,controlbox,controlstheoutputintwostepsand
the airflow in three steps.
Automatic temperature control:
- PTA,automatictemperaturecontrol
Control of mixing cabinet:
- PHR01,controllever,manualdampercontrolor
- PSA01,automaticdamperandtemperaturecontrol
- PSM01,dampermotor,isusedincombination
withPSA01whenseveralmixingcabinetsshouldbe
controlled
50
•Suppliedwithwallbracketthatmakesitpossibletodirect
the airflow down and to the side.
•Timedelaybetweentheoutputsteps.
•Post-runningthermostatforefficientcooling.
•ExternalcontrolpanelPP20/30(orderedseparately)with
master/slavefunction,foruptosixunits,andexternal
thermostat,forexample,RTI2givesgoodandsimplecontrol.
•Colour:white,RAL9016,NCS0500.
•CEcompliant.
Conditions for sound level measurements, see page 67.
Type
3
Voltage
Output
Airflow
Sound
steps
level
[V]
[kW]
[m³/h]
[db(A)]
SE20 400V3N~ 0/10/20
1900/2600 52/60
SE30 400V3N~ 0/10/20/30 1900/2600 52/60
SE305 440V3~
0/7,5/15/23 1900/2600 52/60
500V3~* 0/10/20/30 1900/2600
*) Can be connected to 440V3~ and 500V3~.
HxWxD
Weight
[mm]
576x478x545
576x478x545
576x478x545
576x478x545
[kg]
27
31
32
Control kits Panther 20 -30 kW
Fan speed and thermostat control:
- RTI2orKRT2800,2-steproomthermostats
- PP20,controlbox,controlstheoutputintwostepsand
theairflowintwosteps(SE20)
- PP30,controlbox,controlstheoutputinthreesteps
andtheairflowinthreesteps(SE30,SE305).
Automatic temperature control:
- PTA,automatictemperaturecontrol
Control of mixing cabinet:
- PHR01,controllever,manualdampercontrolor
- PSA01,automaticdamperandtemperaturecontrol
- PSM01,dampermotor,isusedincombination
withPSA01whenseveralmixingcabinetsshouldbe
controlled
Fan heaters - electrically heated
PTRP
4h
2h
1h
12
CBT
CBT
TTF140
PP15/20/30
PTA01
PSA01
KRT1900
PBS01/02
PP15/20/30, control box
Thedesiredoutputandfanspeedcanbesetonthecontrol
box.Upto6unitscanbecontrolledbyonecontrolbox.
Protectionclass:IP44.
PTA01, automatic temperature control
PHR01, control lever for mixing cabinet
Usedwiththemixingcabinet,ifyouwishtocontrolthe
dampermanually.Thepull-rod(notincluded)forthelever
should have a diameter of 8 mm.
PSA01, automatic damper and temperature regulator
Usedonthemixingcabinet.Lowersthetemperatureand
reduces the amount of outdoor air during periods with a low
requirement.Consistsoftimer(weeklytimer),thermostat
with external sensor, potentiometer and damper motor.
Exhaustairfanscanpossiblybecontrolledfromtheautomatic
system.Onedampermotor(PSM01)included.IP55.
PSM01, damper motor
UsedincombinationwithPSA01whenseveralmixingcabinets
shouldbecontrolled.(1dampermotorisincludedinPSA01.)
Protectionclass:IP54.
Accessories Panther 6-12, 20 and 30 kW
Type
Description
PP15
Control box SE06 - SE15, IP44
PP20
Control box SE20, IP44
PP30
Control box SE30 and SE305, IP44
PTA01
Automatic temperature control, IP55
PBS01
Mixing cabinet SE06 – SE15
PBS02
Mixing cabinet SE20, SE30 and SE305
PHR01
Control lever for mixing cabinet
PSM01
Damper motor, IP54
PLR15
Air director SE06 – SE15
PLR30
Air director SE20, SE30 and SE305
PSA01
Automatic damper and temp. control, IP55
PTRP
Drying room kit without fan heater
PFF15
Exhaust air fan SE06 – SE15, IP54
PFF30
Exhaust air fan SE20, SE30 and SE305, IP54
KRT2800
2-step room thermostat, IP55
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
CBT
Electronic timer, IP44
KUR
Digital time switch, IP55
For controls, see pages 62-63.
Fan heaters
PTA01canbeusedtolowertheheatwhennecessary
(1–10°C),forexampleatnightorweekends.Thecontrol
consists of an electronic timer and thermostat with an external
sensor.Thetimeralternatesbetweendayandnightmode.
Protectionclass:IP55.
PBS01/02, mixing cabinet
Savesenergybymixingreturnairwithfreshairinpreset
proportions.Themixingcabinetisdeliveredwithawallframe
and outer wall grille.
PLR15/30, air director
Theairdirectordirectstheairflowverticallyorlaterally.PLR
issnappedonthefrontoftheheater.Torsional(turning)angle
0–35°.
PFF15, exhaust air fan
Canbeusedwithfanheater/mixingcabinettoobtaingood
ventilation.Airflowapprox.1400m³/h.Protectionclass:IP54.
PFF30, exhaust air fan
Canbeusedwithfanheater/mixingcabinettoobtaingood
ventilation.Airflowapprox.2600m³/h.Protectionclass:IP54.
PTRP, drying room kit
ConsistsofexhaustairfanTTF140withflexihoseand
connectionsleeve,thermostatKRT1900andtimerCBT.The
exhaustairfanworksalternatelywith,forexample,afan
heater,whichgivestheshortestpossibledryingtimeand
minimalenergyconsumption.Supplementedwithafanheater
fromthePantherrangewithoutput6-12kW.
51
Fan heaters - water heated
Fan heater SWH
SWHbelongstoanewgenerationofintelligentfanheaters
withSIReintegratedcontrols.SWHandSIRetogethercan
providefullyautomaticroomheating,adaptabletoeacharea
of use.
SWHissuitableforuseinpremiseswherefanheatersare
traditionallyused,suchasindustrialbuildings,aswellas
environments with low sound requirements.
•IntegratedcontrolsystemSIRe.
•Verylowsoundlevel.
•Fivefanspeeds.
•Mountedonthewallorceiling.
•Intendedforwatertemperaturesupto+125°Cand10barin
standard design.
•Colour:RAL9016,NCS0500(white).Aluminiumlouvres.
•CEcompliant.
Fan heater SWH (IPX4)
Type
Output*
Airflow
Sound HxWxD
Weight
level
[kW]
[m³/h]
[dB(A)] [mm]
[kg]
SWH02
12
1120
39
525x515x320
15
SWH12
20
1810
48
600x535x340
19
SWH22
33
3260
55
725x680x370
27
SWH32
51
5860
58
850x820x450
46
SWH33
66
5420
58
850x820x450
46
*) Applicable at water temperature 80/60 °C, air temperature, in +15 °C
Control options
SWHissuppliedwithanintelligentandwelldesignedlow
voltagecontrolsystemSIRewhichcanbecustomisedforeach
uniqueapplicationandenvironment.Thecontrolsystemis
pre-installedinSWHwithanintegratedPCboard.Ifmorethan
oneSWHshouldbecontrolledbyasingleSIRe,anadditional
modularcableSIReCCperunitisneeded.Cablesbetween
unitscaneasilybejoinedtogetherbyusingjointpiece
SIReCJ.SIReissuppliedpre-programmedwithquickfitplug
connectionsandisveryeasytouseandinstall.
SIRelearnstherequirementsandcanprovidefully
automated room heating with calendar function and selectable
switchoffatsettemperaturesforuptonineunits.UsingSIRe
nomoreenergyisconsumedthannecessary.Becausethefan
speed is adapted , the sound level is optimised and is never
higherthanisnecessaryforcomfort.WithSIReAdvanced
itispossibletochoosebetweenEcoandComfortmode
dependentonwhetherenergysavingsoroptimalcomforthas
beenprioritised.SIReAdvancedcanalsobeusedforsimple
and safe ventilation solutions using mixing cabinets, control
isfullyautomaticandalsohasbuilt-infrostprotection.There
arethreedifferentlevelswithdifferentfunctionalitytochoose
from,Basic,CompetentorAdvanced.TheSIRecontrolsystem
can be supplemented with a valve kit for a complete solution.
Functions SIReB Basic
•Manualregulationofthefanandtemperature
•Automaticcontroloffanspeedandtemperaturewith
integrated thermostat.
Functions SIReFC Competent
•AllfunctionsforBasic
•Calendarfunction
•Filteralarm
•SimpleBMScontrol-on/off,fanspeedandalarmfunctions
Functions SIReFA Advanced
•AllfunctionsforCompetent
•Ecomode-extraenergy-efficientmode
•Comfortmode-whencomfortisimportant
•AdvancedBMScontrol
•Maxlimitofreturnwatertemperature.
•Steplessheatcontrol.
•Possibilitytouseanexternalfilterguard.
•Model(SIReFAWM)Forfullyautomaticcontrolofventilation
andheatingwithmixingcabinet.OneSIReFAWMperunitis
needed. Integrated frost protection.
Control - Fan heater SWH
52
Conditions for sound level measurements, see page 67.
Type
Description
SIReB
SIReFC
SIReFA
SIReFAWM
Control system SIRe Basic
Control system SIRe Competent for fan heaters
Control system SIRe Advanced for fan heaters
Control systemSIRe Advanced for fan heaters with
mixing cabinet
Fan heaters - water heated
SIReRTX
SIReUR
SIReWTA
SIRe Competent /Advanced
Included in SIReB Basic:
•SIReB1,integratedPCboardBase
•SIReIT,internaltemperaturesensor
•SIReUB1,controlunit.Wallunitcoverincluded.
•SIReCC,modularcable,RJ12(6/6),5m
Options:
•SIReRTX,externalroomtemperaturesensor
•VOS(P),(pressureindependent)valvekiton/offorVOT,three
wayvalveandactuatoron/off
Included in SIReFC Competent:
•SIReB1,integratedPCboardBase
•SIReIT,internaltemperaturesensor
•SIReUA1,controlunit.Wallunitcoverincluded.
•SIReC1X,PCboardHUBCompetent
•SIReCC,modularcables,RJ12(6/6),3mresp.5m
Options:
•SIReRTX,externalroomtemperaturesensor
•SIReUR,kitforrecessedinstallation
•VOS(P),(pressureindependent)valvekiton/offorVOT,three
wayvalveandactuatoron/off
Included in SIReFA Advanced:
•SIReB1,integratedPCboardBase
•SIReIT,internaltemperaturesensor
•SIReUA1,controlunit.Wallunitcoverincluded.
•SIReA1X,PCboardHUBAdvanced
•SIReOTX,outdoortemperaturesensor
•SIReCC,modularcables,RJ12(6/6),3mresp.5m
Options:
•SIReRTX,externalroomtemperaturesensor
•SIReUR,kitforrecessedinstallation
•SIReWTA,clamp-onsensor
•VMO(P),(pressureindependent)modulatingvalvekitor
VMT,threewayvalveandmodulatingactuator
Included in SIReFAWM Advanced with mixing cabinet:
•SIReB1,integratedPCboardBase
•SIReIT,internaltemperaturesensor
•SIReUA1,controlunit.Wallunitcoverincluded.
•SIReA1X,PCboardHUBAdvanced
•SIReOTX,outdoortemperaturesensor
•SIReWTA,clamp-onsensor
•SMM24,dampermotor
•SIReCC,modularcables,RJ12(6/6),3mresp.5m
Options:
•SIReRTX,externalroomtemperaturesensor
•SIReUR,kitforrecessedinstallation
•VMO(P),(pressureindependent)modulatingvalvekitor
VMT,threewayvalveandmodulatingactuator
Accessories - SIRe
Type
Description
SIReRTX
SIReUR
SIReWTA
SIReCJ4
SIReCJ6
SIReCC603
SIReCC605
SIReCC610
SIReCC615
SIReCC403
SIReCC405
SIReCC410
SIReCC415
External room temperature sensor
Kit for recessed installation
Clamp-on sensor
Joint piece for two pcs RJ11 (4/4)
Joint piece for two pcs RJ12 (6/6)
Modular cable RJ12 3 m
Modular cable RJ12 5 m
Modular cable RJ12 10 m
Modular cable RJ12 15 m
Modular cable RJ11 3 m
Modular cable RJ11 5 m
Modular cable RJ11 10 m
Modular cable RJ11 15 m
Fan heaters
SIRe Basic
Water control
ValvekitVOS(P),VOT,VMO(P)orVMTisusedtocontrolthe
water flow, see final section of this catalogue.
Water control - SWH
Type
Description
Valve kit on/off, low flow, DN15, Kvs 0,90
Valve kit on/off, DN15, Kvs 1,8
Valve kit on/off, DN20, Kvs 3,4
Valve kit on/off, DN25, Kvs 7,2
Pressure independent valve kit on/off, low flow, DN15
Pressure independent valve kit on/off, DN15
Pressure independent valve kit on/off, DN20
Pressure independent valve kit on/off, DN25
3-way control valve and actuator on/off, DN15, Kvs 1,7
3-way control valve and actuator on/off, DN20, Kvs 2,5
3-way control valve and actuator on/off, DN25, Kvs 4,5
Modulating valve kit, low flow, DN15, Kvs 0,40
Modulating valve kit, DN15, Kvs 1,0
Modulating valve kit, DN20, Kvs 2,0
Modulating valve kit, DN25, Kvs 4,0
Pressure independent and modulating valve kit, low flow,
DN15
VMOP15NF Pressure independent and modulating valve kit, DN15
VMOP20
Pressure independent and modulating valve kit, DN20
VMOP25
Pressure independent andmodulating valve kit, DN25
VMT15
3-way control valve and modulating actuator, DN15,
Kvs 1,7
VMT20
3-way control valve and modulating actuator, DN20,
Kvs 2,5
VMT25
3-way control valve and modulating actuator,DN25,
Kvs 4,5
VAT
Adjustement tool for valve kits
VOS15LF
VOS15NF
VOS20
VOS25
VOSP15LF
VOSP15NF
VOSP20
VOSP25
VOT15
VOT20
VOT25
VMO15LF
VMO15NF
VMO20
VMO25
VMOP15LF
53
Fan heaters - water heated
2
3
SWB, mounting brackets
Whennotusingthefiltersectionormixingcabinetthemain
unitissuspendedfromthewallorceilingusingbracketsSWB
(fig2).Bracketsareextraandsuppliedasapair.
6
4
SWFTN, basic filter
Usedasanalternativetothefiltersection.Providestheheating
coilwithbasicprotection.ThefilteriseasilyfittedintotheSW
unitandcanbecleanedfromeitherthetoporbottom.The
SWHunithasare-usablefilter(fig3).
SWF, filter section
Fig.4.Filterstheoutdoorairor/andreturnairfromparticles
thatmightreducetheperformanceandreliabilityofSWH.
Thedisposabledeep-pleatedbagfilterisacassetteofsynthetic
material.FilterclassG85(EU3).Thefiltersectionisequipped
withfilterondelivery.
Note!Ifthefiltersectionisnotusedincombinationwiththe
mixingcabinet,areturnairintake(SWD)isrequired.
SWEF, extra filtercassette
ReplacementfilterforSWF.
SWD, return air intake
Fig.5.Allowsairintakewhenfiltersectionisusedwithout
mixingcabinetSWBS.Returnairintakeisnotrequiredwhen
the mixing cabinet is used.
SWBS, mixing cabinet
Fig.6.Themixingcabinetisusedtocombineventilationwith
heatingbymixingoutdoorairwithreturnair.Themixture
ratioiscontrolledandinfinitelyvariablewithadamper,either
manuallyorwithadampermotor.
SWY, outer wall grille
Fig.7.Forintakeoffreshairintothemixingcabinet.Grilleof
hotzinc-platedsteelpanels.
SWLR, extra air director
Fig.8.Todirecttheairstreamsideways.Ondelivery,SWHis
equipped with an air director for vertical direction of the air
stream.Individuallyadjustablelouvresinanodisedaluminium.
TheextraairdirectorismountedtoSWHbyhookingitonto
the existing air director.
54
1
8
5
1) Fan heater SWH
2) Mounting brackets SWB
3) Basic filter SWFTN
4) Filter section SWF
5) Return air intake SWD
6) Mixing cabinet SWBS
7) Outer wall grille SWY
8) Extra air director SWLR
Accessories - Fan heater SWH and SWS
Type
Description
SWB0
SWB1
SWB2
SWB3
SWFTN02
SWFTN1
SWFTN2
SWFTN3
SWF1
SWF2
SWF3
SWEF1
SWEF2
SWEF3
SWD1
SWD2
SWD3
SWBS1
SWBS2
SWBS3
SWY1
SWY2
SWY3
SWLR1
SWLR2
SWLR3
Mounting brackets SWH/SWS02
Mounting brackets SWH/SWS12
Mounting brackets SWH/SWS22
Mounting brackets SWH/SWS32/33
Basic filter SWH/SWS12
Basic filter SWH/SWS12
Basic filter SWH/SWS22
Basic filter SWH/SWS32/33
Filter section SWH/SWS12
Filter section SWH/SWS22
Filter section SWH/SWS32/33
Extra filter cassette SWH/SWS12
Extra filter cassette SWH/SWS22
Extra filter cassette SWH/SWS32/33
Return air inlet (SWF1) SWH/SWS12
Return air inlet (SWF2) SWH/SWS22
Return air inlet (SWF3) SWH/SWS32/33
Mixing cabinet SWH/SWS12
Mixing cabinet SWH/SWS22
Mixing cabinet SWH/SWS32/33
Outer wall grille SWH/SWS12
Outer wall grille SWH/SWS22
Outer wall grille SWH/SWS32/33
Extra air director SWH/SWS12
Extra air director SWH/SWS22
Extra air director SWH/SWS32/33
7
Fan heaters - water heated
Fan heater SWS
3
2
FanheaterSWSisintendedforwater-heatingorcooling.SWS
issuitableforplaceswherefanheatersaretraditionallyused,
such as industrial premises, workshops and storage rooms.
Thefanheatercanbemountedonthewallortheceiling.By
turning the unit the water connections will be positioned on
the left or right side.
FanheaterSWShasacompactandfunctionaldesignwell
suitable for the applications it is intended for.
7
6
4
Fan heater SWS (IPX4)
2
Type
Voltage Output* Airflow Sound HxBxD
Weight
level
[V]
[kW]
[m³/h] [dB(A)] [mm]
[kg]
SWS02 230V~
12
1260
50
470x520x260 14
SWS12 230V~
19
2340
57
545x540x275 18
SWS22 230V~
30
3560
58
675x690x275 26
SWS32 230V~
50
6300
64
800x830x350 45
SWS33 230V~
65
6090
64
800x830x350 45
SWS323 400V3~ 48
5890
62
800x830x350 45
SWS333 400V3~ 62
5660
62
800x830x350 45
*) Applicable at water temperature 80/60 °C, surrounding temperature
+15 °C, fan position: max.
Control options 230V~
Control by thermostat only
-KRT1900orT10/TK10,roomthermostat
-TVV20/25,valve+SD20,actuator
5-step control of airflow only
-RE1,5,5-stepregulatormax1,5A,or
RE3,5-stepregulatormax3A,or
RE7,5-stepregulatormax7A
Thermostat and 5-step control
-RE1,5,5-stepregulatormax1,5A,or
RE3,5-stepregulatormax3A,or
RE7,5-stepregulatormax7A
-KRT1900orT10/TK10,roomthermostat
-TVV20/25,valve+SD20,actuator
Control options 400V~
2-step control of airflow only
-SWYD1,2-stepchange-overswitchforairflow(Y/D)
-STDT16,thermalcontactmotorprotection
Termostatstyrning av värmen och 2-stegsreglering av luftflödet
-SWYD1,2-stepchange-overswitchforairflow(Y/D)
-STDT16,thermalcontactmotorprotection
-KRT1900orT10/TK10,roomthermostat
-TVV20/25,valve+SD20,actuator
Conditions for sound level measurements, see page 67.
5
1
8
1) Fan heater SWS
2) Mounting brackets SWB
3) Basic filter SWFTN
4) Filter section SWF
9
5) Return air intake SWD
6) Mixing cabinet SWBS
7) Outer wall grille SWY
8) Extra air director SWLR
9) Drip tray SWST
RE1,5/RE3/RE7, 5-step change-over switch for air flow
Controlstheairflowin5steps.RE1,5 controls maximum 1,5
A.RE3controlsmaximum3A.RE7controlsmaximum7A.To
controltheheat,asuitablethermostatandavalve+actuator
areneeded.IP54.
Fan heaters
•Mountedonthewallorceiling.
•Intendedforwatertemperaturesupto+125°Cand10barin
standard design.
•Colour:grey.Louvresinanodisedaluminium.
•CEcompliant.
STDT16, thermal contact motor protection
Switchesoffthesupplyvoltagetothemotorwhenthethermal
contactinthemotorwindingsistripped.Themotorprotector
isresetbypressingtheblackbuttonassoonasthemotor
windingshavecooledsufficiently.IP55.
SWYD1, 2-step change-over switch for air flow (Y/D)
Controlstheairflowintwosteps.Onechange-overswitchfor
eachunit.IP66.
SWST, drip tray
Usedtocollectcondensationwhentheunitisusedforcooling.
Forinformationaboutotheraccessories,seefanheaterSWH.
Accessories - Fan heater SWS
Type
Description
RE1,5
RE3
RE7
T10
TK10
KRT1900
TVV20
TVV25
SD20
STDT16
SWYD1
SWST02
SWST1
SWST2
SWST3
5-step change-over switch for airflow 1,5 A
5-step change-over switch for airflow 3 A
5-step change-over switch for airflow 7 A
Room thermostat, IP30
Room thermostat with knob, IP30
Room thermostat, IP55
2-way control valve DN20
2-way control valve DN25
Actuator
Thermal contact motor protection, IP55
2-step change-over switch for air flow (Y/D), IP66
Drip tray SWS02
Drip tray SWS12
Drip tray SWS22
Drip tray SWS32/33
55
Fan heaters - water heated
Fan heater SWT
TheSWTfanheaterisusedforheatingentrances,stores,
industrial premises, workshops, sports halls, garages and shops.
ThelowheightmeansthatSWTcanalsoberecessedintoa
suspended ceiling.
TheSWTfanheaterhasarobustdesigninwhiteenamelled
steelpanels.SWTisintendedforwaterconnectionandis
ceiling mounted.
•Installeddirectlytotheceilingorsuspendedfrombrackets.
•Intendedforwatertemperaturesupto+80°Cand10bar.
•Twofanspeeds.
•Colour:white.
•CEcompliant.
Fan heater SWT (IPX4)
Type
2
1
3
1) Fan heater SWT
2) Filter SWTCF
3) Air director SWTCL
4) Extension collar SWTCE
4
Output* Airflow
Sound
HxWxD
Weight
level
[kW]
[m³/h]
[dB(A)]
[mm]
[kg]
SWT02
11
1100
53
330x705x535
19
SWT12
18
2000
57
355x825x675
26
SWT22
40
3900
60
415x1135x710
41
*) Applicable at water temperature 80/60 °C, air temperature, in +15 °C
SWTCF, filter
Withthefilterinstalledtheintervalforcleaningthewatercoil
isextended.Thefilterisdeliveredintwopieces.
SWTCL, air director
Control options
Control by thermostat only
Toavoiddraughtsatlowceilingheightstheairdirectorcanbe
installed to direct air more to the side.
-KRT1900orT10/TK10,roomthermostat
-TVV20/25,valve+SD20,actuator
SWTCE, extension collar
2-step control of airflow only
-CB20,controlbox
Thermostat and 2-step control
-CB20,controlbox
-KRT1900orT10/TK10,roomthermostat
-TVV20/25,valve+SD20,actuator
t
5-step control of airflow only
-RE1,5,5-stepregulatormax1,5A,or
RE3,5-stepregulatormax3A,or
RE7,5-stepregulatormax7A
Thermostat and 5-step control
-RE1,5,5-stepregulatormax1,5A,or
RE3,5-stepregulatormax3A,or
RE7,5-stepregulatormax7A
-KRT1900orT10/TK10,roomthermostat
-TVV20/25,valve+SD20,actuator
CB20, control box
Controlstheairflowin2steps.Deliveredinencapsulatedbox
forwallmounting.Cancontrolseveralunits.Maxinput12A.
IP44.
RE1,5/RE3/RE7, 5-step change-over switch for air flow
Controlstheairflowin5steps.RE1,5 controls maximum
1,5A.RE3controlsmaximum3A.RE7 controls maximum
7A.Tocontroltheheat,asuitablethermostatandavalve+
actuatorareneeded.IP54.
56
AthighinstallationtheoutletcollarfortheSWTcanbe
extended.Thisincreasesthethrowpatternoftheair.
SWTCE02increasesthethrowpatternto4-7m,SWTCE12
increasesitto5-8mandSWTCE22to7-12m.
Accessories - Fan heaters SWT
Type
Description
CB20
RE1,5
RE3
RE7
T10
TK10
KRT1900
RTI2
RTI2V
TVV20
TVV25
SD20
SWTCE02
SWTCE12
SWTCE22
SWTCF02
SWTCF12
SWTCF22
SWTCL02
SWTCL12
SWTCL22
Control box
5-step change-over switch for airflow 1,5 A
5-step change-over switch for airflow 3 A
5-step change-over switch for airflow 7 A
Room thermostat, IP30
Room thermostat with knob, IP30
Room thermostat, IP55
2-step room thermostat, IP44
2-step room thermostat with knob, IP44
2-way control valve DN20
2-way control valve DN25
Actuator
Extension collar 350 mm SWT02
Extension collar 350 mm SWT12
Extension collar 350 mm SWT22
Filter SWT02, 2 pcs
Filter SWT12, 2 pcs
Filter SWT22, 2 pcs
Air director SWT02
Air director SWT12
Air director SWT22
Conditions for sound level measurements, see page 67.
Industrial ceiling fan ICF
Industrial ceiling fan ICF
•Thebladespushdownlargevolumesofairwithoutcausing
excessive air speed.
•Canoperateclockwiseandanti-clockwise.
•Canopywithvibrationabsorption.
•Fanbladesanddownrodcoatedwithzinc.
•Colour:white,NCSS0505-R90B.
•ProtectionclassICF20:IPX0.
•ProtectionclassICF55:IPX5.
•ApprovedbyIMQandCEcompliant.
Control options
-CAR15,automaticfanspeedcontrol,formaximum15fans,
reversible
-CFR1R,5-stepcontrolfor1fan,reversible
-RE5,5-stepcontrolforamaximumof12fans
-PE1,variablefanspeedcontrolforamaximumof2fans
-PE2,5,variablefanspeedcontrolforamaximumof6fans
CAR15, automatic fan speed control
Automaticfanspeedcontrol,through
external sensor, in accordance with
variations in the temperature between the
ceilingandthefloor.Built-inswitchfor
reversedrotation.Controlsamaximumof
15fans.IP33.
CAR15
Fan heaters
Ceilingfansareusedprimarilytoequalizethetemperature
in rooms with high ceilings, such as industrial and warehouse
buildings,gymnasiums,andshops.Severalcontrolsaswellas
downrodsandbladesofdifferentsizesareavailable,makingit
possibletoadaptceilingfanICFtoalmostallapplications.
CeilingfanICFpushesthewarmairfromtheceilingand
thus lowers the temperature there, the heat losses through the
roofandwallsarereducedandinmanycases,heatingcosts
canbereducedbyupto30%.
CeilingfanICFisahighquality,maintenancefreeproduct
withlonglifetime,whichresultsinaveryshortpay-offtime,
thatisoftenlessthanoneyear.
IndustrialceilingfanICFhasafunctionaldesignandwhite
colourwhichblendswellinmostpremises.Thelowsound
level makes it even more discreet.
CFR1R, 5-step control
5-stepcontrol.Built-inswitchforreversed
rotation.Controlsamaximumof1fan.
IPX0.
CFR1R
RE5, 5-step control
5-stepcontrol.Controlsamaximumof12
fans.IP54.
Ceiling fan ICF (ICF20:IPX0 / ICF55:IPX5)
Type
ICF20
ICF55
Voltage
[V]
230V~
230V~
Output
[W]
70
70
3
PE1/PE2,5, variable fan speed control
Airflow
[m³/h]
13500
13500
Height x Ø
[mm]
545x1422
545x1422
Weight
[kg]
6,2
6,2
Single-phasemanualthyristorforvariable
speedadjustmentofthefanandon/off
regulation.Externalmounting(IP54)or
recessedmounting(IP44).PE1controls
amaximumof2fans.PE2,5controlsa
maximum of 6 fans.
RE5
PE1/PE2,5
Accessories - ICF
a
a/2
a‘
Type
Description
CAR15
CFR1R
PE1
PE2,5
RE5
CFAP200
CFAP750
CFB900
CFB1200
Automatic fan speed control
5-step fan speed control for 1 fan
Stepless fan speed control for 2 fans
Stepless fan speed control for 6 fans
5-step fan speed control for 12 fans
Short downrod, total height 395 mm
Long downrod, total height 945 mm
Fan blades Ø 914 mm (3 pcs)
Fan blades Ø 1218 mm (3 pcs)
a‘/2
Ceiling height (m)
Distance between fans a (m)
Recommended distance between fans
4
6
8
10
12
5
7
8
9
10
57
Convectors
The circulation of air that forms in a room where the
air is affected by a heat source is called convection.
The air gets warm and rises, then cools and returns
to be heated again. Heat disperses effectively while
the upward directed warm air stream is utilized to
counteract cold draughts from windows for example.
Convectors and radiators are simple to install.
Our range contains a convector to suit all needs:
small, discreet, robust and hard-wearing or quick and
economical, all with the same high level of quality.
Bench heater SH
Mini radiator/Frost guard
BenchheaterSHisdesignedforusewithchurchpews,waiting
roombenchesandthelike.Thebenchheaterisinstalled
undertheseatanddistributesheatintheoccupiedzone
through convection and radiant heat.
Asheatisproducedassoonastheheaterisswitchedon,SH
isalsoanidealandefficientoptioninslowlyheatedbuildings
suchaschurches.Onlyheatingthebuildingwhennecessary
helps to keep down heating costs.
BenchheaterSHhasadiscreetdesignespeciallyadaptedto
fit under benches and seats.
Theminiradiator/frostguardgivesoffalotofheatdespitethe
smallsize.Thecompactradiatorsaresuitableforproviding
frostprotection,butcanalsobeusedtoheatmanydifferent
areas, for example, homes, close to water pipes, small
warehouses, greenhouses and electrical cabinets.
Theminiradiator/frostguardisavailableinwhiteor
stainlesssteeldesignsandisveryeasytopositiononaccount
ofitssmallsize.
•Approvedforserialconnection.
•Equippedwithproteciongrilleandtubeelementofstainless
steel.
•Dualreflectors(externalandinternal)givedownwardheat
dispersion.
•Outerreflectorisofzinc-platedsteelpanelsandtheheateris
greylacquered.Colour:NCS4000,RAL7036(grey).
•CEcompliant.
•Mountedhorizontally(FML/FMLR)orvertically(FMS)onthe
wall.
•Stainlesssteeltubularelement.
•Equippedwith1metrelongcordwithplugforconnectionto
an earthed outlet socket.
•Integratedoverheatingprotection.
•Integratedthermostatwithsettingrange+5–+35°C.
•Colourfront:NCS1103-Y06R(white).FMLR200hasa
stainless steel design.
•CEcompliant.
Bench heater (IP21)
Frostguard FMS, FML, FMLR (IP31)
Type
SH17521
SH17531
SH25021
SH25031
SH37521
SH37531
58
3
Voltage
[V]
230V~
400V2~
230V~
400V2~
230V~
400V2~
Heat output
[W]
175
175
250
250
375
375
LxHxD
[mm]
700x100x200
700x100x200
1000x100x200
1000x100x200
1500x100x200
1500x100x200
Weight
[kg]
1,4
1,4
1,9
1,9
2,9
2,9
Type
FMS200
FMLR200
FML200
FML300
FML450
Voltage
[V]
230V~
230V~
230V~
230V~
230V~
3
Heat output
[W]
200
200
200
300
450
LxHxD
[mm]
90x298x68
298x90x68
298x90x68
398x90x68
498x90x68
Weight
[kg]
0,7
0,7
0,7
0,9
1,1
Convectors
TWTC
TWT
Ribbed pipe radiator
Thermowarm
Frico's ribbed pipe radiators are designed for harsh
environments and are approved for wet rooms, but are also
availableindesignsforroomsatriskoffire.Theretrodesign
has also created a new application area in modern housing.
Frico's ribbed pipe radiators have a hard wearing and robust
designindarkgreensheetsteel.Thecompactformatmeans
the radiator has a small footprint, but gives a lot of heat.
Thermowarmisaseriesofeasilyinstalledconvectorsdesigned
for public buildings such as changing rooms, stores and
toilets.TWTCcanalsobeusedincorrosiveandaggressive
environments.TWT200hasasurfacetemperatureaslow
as60°C,whichmakesitidealfordaycarecentresand
bathrooms.
Thermowarmiseasytopositionandhas,despiteitssmall
size,alargeheatoutput.Thethreedifferentsurfacefinishes:
white,greycoveredpanelcoveredandstainlesssteel,make
Thermowarmsuitableformostenvironments.Thefront
cover can be opened making it straightforward to keep the
convectorscleanandtidy.
Ribbed pipe radiator (IP44)
Type
125-12B
125-22B
125-32B
125-42B
126-32B
126-42B
126-52B
127-22B
127-42B
Voltage
[V]
230V~
230V~
230V~
230V~
230V~
230V~
230V~
230V~
230V~
TWT100 (IP44) white, with circuit breaker
3
Heat output
[W]
200
375
575
775
575
775
1150
500
800
•Withribbedflangesandtubularelements.
•Integratedthermostatwithsettingrange0–+35°C.
•Resettableoverheatingprotectionalongthefulllengthofthe
convector.
•ColourTWT100andTWT300:whitefront,RAL9016,
NCS0500,greysides
ColourTWT200:greycoveredfrontpanel,greysides
ColourTWTC:stainlesssteeldesign,blacksides
•CEcompliant.
LxHxD
[mm]
370x180x185
530x180x185
730x180x185
880x180x185
730x180x185
880x180x185
1185x180x185
980x180x185
1925x180x185
Weight
[kg]
2,4
3,3
4,5
5,5
4,7
5,7
7,5
10,9
33,3
Type
TWT10321
TWT10331
TWT10521
TWT10531
TWT11021
TWT11031
Voltage
[V]
230V~
400V~
230V~
400V~
230V~
400V~
Heat output
[W]
300
300
500
500
1000
1000
3
LxHxD
[mm]
345x205x123
345x205x123
465x205x123
465x205x123
765x205x123
765x205x123
TWT200 (IP44) covered front, with circuit breaker 60 °C
Type
TWT20321
TWT20331
TWT20521
TWT20531
TWT21021
TWT21031
Voltage
[V]
230V~
400V~
230V~
400V~
230V~
400V~
Heat output
[W]
300
300
500
500
1000
1000
TWT30321
TWT30521
TWT31021
Voltage
[V]
230V~
230V~
230V~
Heat output
[W]
300
500
1000
Weight
[kg]
1,5
1,5
2,0
2,0
3,0
3,0
3
LxHxD
[mm]
345x205x123
465x205x123
765x205x123
TWTC (IP54) stainless steel, with mains cord and plug
Type
3
LxHxD
[mm]
345x205x123
345x205x123
465x205x123
465x205x123
765x205x123
765x205x123
TWT300 (IP21) white, with mains cord and plug
Type
Weight
[kg]
1,5
1,5
2,0
2,0
3,0
3,0
Convec tors
•Theribbedpiperadiatorisavailableinthefollowingdesigns:
-Model 125, without output selector.
-Model 126, with output selector that regulates the heat in
three steps.
-Model 127,withoutoutputselector,sand-filledand
suitable for rooms at risk to fire.
•Theribbedflangesincreasetheheatingsurfaceandprovide
good heat transfer combined with a compact design.
•Resettableoverheatingprotectionalongthefulllengthofthe
ribbed pipe radiator.
•Aprotectivesteelcasegivealowersurfacetemperatureand
extraprotectionagainstimpact(model125and126).
•Colour:darkgreen,RAL6005,NCS7020-B90G.
•CEcompliant.
Weight
[kg]
1,5
2,0
3,0
3
TWTC30321
Voltage
[V]
230V~
Heat output
[W]
300
LxHxD
[mm]
345x205x123
Weight
[kg]
1,5
TWTC30521
230V~
500
465x205x123
2,0
TWTC31021
230V~
1000
765x205x123
3,0
59
Convectors
Fan convector PF
FanconvectorPFissuitableformostenvironments,for
example, homes and offices. It is also ideal for use in buildings
thatarerarelyused,forexample,weekendcottages,where
quickheatingisrequired.Thefanconvectoralsohasvery
gooddryingproperties.Modelsupto800Whaveasurface
temperature of less than 60°Cwhichmakesthemextremely
suitablefordaycarecentresandbathrooms.
Thefanconvectorconsumeslessenergythanstandard
convectors.Theairflowfromtheconvector,whichbalances
the temperature difference between the floor and ceiling, gives
higherefficiencyandlowerenergyconsumptioncomparedto
convectors without a fan.
FanconvectorPFhasanattractiveandcleandesignina
whitefinish.Abrushedaluminiumfrontisavailableasan
accessory.Thelowsurfacetemperaturemakesitpossible
tofinishthefrontpanelinanycolourorafilmfinishcanbe
applied.
•FanconvectorPFisavailableinthefollowingdesigns:
-PFE is equipped with a 1.2 metre long cord with plug for
connectiontoanearthedoutletsocket(230V~).Canbe
used as a portable unit, a floor stand is available as an
accessory.
-PFDisdesignedforpermanentinstallation(400V2~).
-PFWisforwaterbasedheating.Equippedwitha1.2
metre long cord with plug for connection to an earthed
outletsocket.Suppliedwithtwo,0.9mPEXhosesforeasy
installation.Workswithaheatpump.
•Lowsoundlevel.
•Master/slavefunction(PFE/PFD).
•Integratedthermostatwithsettingrange5–+35°C(PFE/
PFD).
•Preparedfornighttariffsviaexternalsignal(PFE/PFD).
•DepthwallbracketPFE/PFD:30mm.
•DepthwallbracketPFW:45mm.
•Colour:white,RAL9016,NCS0500(standard),brushed
aluminiumasanaccessory.
•CEcompliant.
60
Fan convector PFE/PFD, electrically heated (IP23)
Type
PFE5
PFE8
PFE10
PFE12
PFD5
PFD8
PFD10
PFD12
Voltage
[V]
230V~
230V~
230V~
230V~
400V2~
400V2~
400V2~
400V2~
Heat output
[W]
500
800
1000
1200
500
800
1000
1200
Fan convector PFW, water heated (IP23)
Type
Voltage
3
LxHxD
[mm]
598x330x90
598x330x90
598x330x90
598x330x90
598x330x90
598x330x90
598x330x90
598x330x90
Weight
[kg]
6
6
6
6
6
6
6
6
2
Airflow Sound LxHxD
Heat
Weight
level*2
output*1
[kW]
[V]
[m3/h] [dB(A)] [mm]
[kg]
PFW10
230V~
1,1
59
42/32
598x330x90 7,3
PFW20
230V~
3,0
65
44/33
1058x330x90 13
*1) Applicable at water temperature 80/60 °C, air temperature, in +20 °C.
*2) Conditions: Distance to the unit: 3 metres. Directional factor: 2.
Equivalent absorption area: 200 m2.
Accessories - PFE/PFD/PFW
Type
Description
PFFAL
PFFS
Front, brushed aluminium
Floor stand PFE/PFD
Dehumidifier/Hand dryer
Dehumidifier LAF10
Hand dryer HD2C
LAF10isadehumidifierthatreducessurplusmoistureatthe
sametimeasitprovidesadditionalheattotheroom.The
dehumidifierisalsoidealforuseinareasfrequentlyexposed
to moisture, for example, basements, warehouses, washrooms,
and sports halls or after minor water damage.
LAF10isveryeasytouseandhaslowpowerconsumption.
Withacontrolledhumidityyoureducetheriskofmoisture
damage indoors that can be expensive to repair.
Withitsstraightforwarddesignandneutralfinish,LAF10is
suitableformostenvironments.Itscastorsandcarryinghandle
makeiteasytomoveandplace.
HD2Cisahanddryerofmoderndesigninstainlesssteel
intendedtobeinstalledinpublicsanitaryareassuchasrest
roomsanddressingrooms.Nopapertowelwasteandthe
premises are kept nice and clean.
HanddryerHD2Chasastainlesssteelhousingofmodern
designandiseasytokeepclean.Theroundedtopmakesit
impossibletoputobjectsonthehanddryer.
•Dehumidifyingcapacity:
5litres/dayattheconditionRT27°C,RH60%.
10litres/dayattheconditionRT30°C,RH80%.
•Inbuiltfilter.
•Automaticdefrosting.
•Inbuiltcollectioncontainerwithlevelguardandindicator
lamp.
•Adjustablehygrostat(30-80%relativehumidity).
•Twofanspeeds.
•Equippedwitha2metrelongcordwithplugforconnection
to an earthed outlet socket.
•Operatingtemperaturerange:8-35°C
•Powerconsumption:220W
•Refrigeranttype(Freon-free):R134a
•DimensionsHxWxD:550x270x364mm
•Weight:13,5kg
•Colour:white,Pantone428C.
•ApprovedbyTÜVandCEcompliant.
•Highairspeedandhighoutputgivesashortdryingtime.
•Built-inthermocontactwithautomaticresetprotectsfrom
overheating.
•HD2Cstartswhentheuser’shandsare5-10cmunderthe
appliance(photocellwithadjustablesensitivity).Stops2-3s
afterthehands’removal.
•Solidhousingin1.2mmstainlesssteel.
•DimensionsHxWxD:322x260x148mm.
•CEcompliant.
Hand dryer HD2C (IPX3)
Type
HD2C
Output
[W]
2125
Airflow
[m3/h]
150
Airspeed
[m/s]
28
Amperage Weight
[A]
[kg]
9,2
4,0
Type
Voltage
Air flow
LAF10
[V]
230V~
[m3/h]
90/115
Sound
level*1
[dB(A)]
40/45
Amp*2
Weight
[A]
1,0
[kg]
13,5
*1) Conditions: Distance to unit 3 metres.
*2) Applicable at water temperature 20 ºC.
Capacity (litres/day)
Type
LAF10
At 30°C
80%RH
10,0
At 27°C
60%RH
5,0
At 20°C
60%RH
4,0
Convec tors
Dehumidifier LAF10 (IP21)
At 8°C
60%RH
1,8
61
Thermostats and controls
The control system is the intelligent centre and the
”brain” of a heating system and essential for good
comfort level and low energy consumption. The
temperature of an electric heating system can be
quickly, easily and precisely regulated and is more
responsive than any other heating system.
Frico offers a wide range of thermostats and controls,
read more under each product or in the Frico
catalogues.
T10
TKS16(400)
TK10
TD10
RTI2
T, TK, TD, basic offer thermostats
RTI, electronic 2-step thermostats
Processorcontrolledthermostatsforroom/floorheating.
Availablewithconcealed/visibleknobordigitaldisplay.Model
withvisibleknobalsoavailablewithswitchandin400V.
On/offcontrol(forslowsystems)orproportionalcontrol(for
fastersystems)inthesamethermostat.TD10hasadjustable
P-bandandtimeofcycle.
Internaland/orexternalsensors(externalsensorRTS01
availableasanaccessory)givethepossibilityofselectingthe
sensorfunctione.glimitingexternalsensors(min/max).Save
reductioneitherbybuilt-inmanualswitchorviaexternal
timer.CEcompliant.
Processorcontrolled2-stepthermostatsforroomheating/
cooling.Availablewithconcealedorvisibleknob.Adjustable
temperaturedifferencebetweenthesteps(1–10degrees).
Savereductionviaexternalconnectiontimer(1–10degrees).
Externalsensor(RTS01)availableasanaccessory.
Highprotectionclass(IP44).CEcompliant.
Type
T10
TK10
TKS16
TKS16400
TD10
62
RTI2V
Voltage
[V]
230~
230~
230~
400V2~
230V~
Max input
[A]
10
10
16
16
10
Setting range
[°C]
5 - +30
5 - +30
5 - +30
5 - +30
5 - +37
HxWxD
[mm]
80x80x31
80x80x31
80x80x39
80x80x39
80x80x31
Type
RTI2
RTI2V
Voltage
[V]
230V~
230V~
Setting range
[°C]
5 - +35
5 - +35
Accessories
Type
Description
RTS01
External floor/duct sensor
HxWxD
[mm]
155x87x43
155x87x43
Thermostats and controls
KRT1900/1
KRTV19
TBK10
KRT2800
TBKS10
KRT, capillary tube thermostats
TBK, bimetal thermostats
Capillarytubethermostatsforroomheating/cooling.Available
with concealed and visible knob, and control in 1 or 2 steps.
KRT2800controlsin2stepsandhasadjustabletemperature
differencebetweenthesteps(1–4degrees).KRT1901hasa
temperaturerangeof-35–+10°C.Highprotectionclass(IP44
resp.IP55).CEcompliant.
Mechanicalbimetalthermostatswithaccelerationresistance
forroomheating/cooling.TBKS10alsohasa1-poleswitch.
CEcompliant.
Type
Voltage
[V]
230/400V~
230/400V~
230/400V~
230/400V~
KRT1900
KRT1901
KRTV19
KRT2800
Setting range
[°C]
0 - +40
-35 - +10
0 - +40
0 - +40
Type
Voltage
[V]
230V~
230V~
TBK10
TBKS10
HxWxD
[mm]
165x57x60
165x57x60
165x57x60
165x57x60
Setting range
[°C]
5–30
5–30
CBT
HxWxD
[mm]
80x80x43
80x80x43
KUR
CBT, electronic timer
KUR, digital time switch
Electronictimerwithalternatingcontact.Settingrange1/2-12-4or4-8-16-24hoursrespectively.Thesettingrangecanbe
limiteddowntoamaximumtimeof1/2hours.IP44.
Digitalweeklytimerwith8differentprogramsteps(36
memoryplaces)equippedwithachangeovercontact.Max.
breakingcurrent:10A.IP55.
Type
Voltage
[V]
230V~
CBT
Type
Voltage
[V]
230V~
KUR
HxWxD
[mm]
175x85x105
Thermostats
Basic offer
T10
TK10
Electronic 2-step
TKS16
TD10
TKS16400
RTI2
KRTV19
KRT2800
TBK10
TBKS10
X
X
X
X
X
X
X
X
X
X
X
Internal sensor
X
X
X
X
X
X
X*¹
X*²
X*¹
X*²
X*¹
X*¹
X*¹
X*¹
X*²
X*²
X*²
X*²
X
X
X
X
X
1-pole switch
Volt free contact
X
X
Contact, 1-pole closing
X
X
X
X
X
Contact, 1-pole alternating
X
Internal setting
X
Processor controlled
X
X
X
X
X
X
X
Capillary tube
Adjustable temp.diff. between the
steps
*¹) External sensor (RTS01) as accessory.
*²) Can be used with an external timer.
*³) See manuals on www.frico.se.
X
X
X
X
X
X
X
X
Bimetallic
2-step
X
X
Advanced extra functions*³
Fits wall box system
X
X
Digital display
Heating or cooling function
Bimetallic
RTI2V
External sensor
Save reduction
Capillary tube
KRT1900
KRT1901
Ther mos t at s and c ontrols
Functions |
HxWxD
[mm]
155x87x43
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
63
Water control
VOS
VOSP
TBVC
SD230
AV
BPV10
VMO
TBVCMP
SD230
AV
TBVCM
SDM24
TBVCMP
SDM24
AV
ST23024
AV
ST23024
BPV10
VOT
VMOP
VMT
Completevalvekitswithmultifunctionalterminalvalvesmakes
new functions possible and ensures stable flows and exact control
usingthemodulatingactuator.Theyaresuppliedatdifferentlevels
andhavealowinstallationcostwithfewcomponents.Thevalve
kitgivesexactadjustmentandmeansextraenergysavings.Usedto
controlthewatersupplytowaterheatedunitswithcontrolsystem
SIRe.
Used with SIRe Basic and Competent
Used with SIRe Advanced
VOS, valve kit on/off
VMO, modulating valve kit
Twowaycombinedcontrolandadjustmentvalvewithon/off
actuator,shut-offvalveandbypass.DN15/20/25.230V.Used
withSIReBasicandCompetent.
Thevalvekitconsistsofthefollowing:
•TBVC,regulationandadjustmentvalve
•SD230,actuatoron/off230V
•AV,shutoffvalve
•BPV10,bypassvalve
Twowaycombinedcontrolandadjustmentvalvewith
modulatingactuatorandshut-offvalve.DN15/20/25.24V.Used
withSIReAdvanced.
Thevalvekitconsistsofthefollowing:
•SDM24,modulatingactuator24V
•TBVCM,regulationandadjustmentvalve
•AV,shutoffvalve
•ST23024,24Vtransformerforvalveactuator(invalvekit
with24V)
VOSP, pressure independent valve kit on/off
Twowaypressureindependentcontrolandadjustmentvalve
withon/offactuator,shut-offvalveandbypass.DN15/20/25.
230V.UsedwithSIReBasicandCompetent.
Thevalvekitconsistsofthefollowing:
•TBVCMP,pressureindependentregulationandadjustment
valve
•SD230,actuatoron/off230V
•AV,shutoffvalve
•BPV10,bypassvalve
VOT, three way control valve and actuator on/off
VMOP, pressure independent and modulating valve kit
Twowaypressureindependentcontrolandadjustmentvalve
withmodulatingactuatorandshut-offvalve.DN15/20/25.24V.
UsedwithSIReAdvanced.
Thevalvekitconsistsofthefollowing:
•TBVCMP,pressureindependentregulationandadjustment
valve
•SDM24,modulatingactuator24V
•AV,shutoffvalve
•ST23024,24Vtransformerforvalveactuator(invalvekit
with24V)
DN15/20/25.230V.UsedwithSIReBasicandCompetent.
VMT, three way control valve and modulating actuator
DN15/20/25.24V.UsedwithSIReAdvanced.
64
Type
Flow
Connection
Kvs
Type
Flow
Connection
Kvs
VOS15LF
VOS15NF
VOS20
VOS25
VOSP15LF
VOSP15NF
VOSP20
VOSP25
VOT15
VOT20
VOT25
Low flow
Normal flow
Normal flow
Normal flow
Low flow
Normal flow
Normal flow
Normal flow
Normal flow
Normal flow
Normal flow
DN15
DN15
DN20
DN25
DN15
DN15
DN20
DN25
DN15
DN20
DN25
0,90
1,8
3,4
7,2
1,7
2,5
4,5
VMO15LF
VMO15NF
VMO20
VMO25
VMOP15LF
VMOP15NF
VMOP20
VMOP25
VMT15
VMT20
VMT25
Low flow
Normal flow
Normal flow
Normal flow
Low flow
Normal flow
Normal flow
Normal flow
Normal flow
Normal flow
Normal flow
DN15
DN15
DN20
DN25
DN15
DN15
DN20
DN25
DN15
DN20
DN25
0,40
1,0
2,0
4,0
1,7
2,5
4,5
Water control
TBVCMP
AV
BPV10
SD230
SDM24
VAT
TBVC/TBVCM, regulation and adjustment valve
BPV10, by-pass valve
Theregulationandadjustmentvalvecanbeusedtofinely
adjustorshutoffthewaterflowmanually.Thewaterflowis
setusingtheadjustmenttool(option).Theregulationand
adjustment valve also has a shut off function, which makes
maintenance easier, and a self sealing measurement outlet
whichallowsforeasyandfastmeasurements.
Ifthevalveisclosed,alowflowpassesthroughtheby-pass
valve(BPV10)sothatthereisalwayshotwaterinthewater
coil.Thisistoprovidequickheatsupplywhenadooris
opened but also to provide a degree of frost protection.
TBVCMP, regulation and adjustment valve
Theregulationandadjustmentvalvecanbeusedtofinely
adjustorshutoffthewaterflowmanually.TBVCMPis
independent of the available differential pressure, which
contributestostableandaccurateregulation(ensuresthe
correct flow to the heater even if the differential pressure in
therestofthepipesystemchanges).Thewaterflowisset
usingtheadjustmenttool(option).Withtheregulationand
adjustmentvalveeasyflush-throughisalsopossible,which
makesforeasyandfastmaintenance.
AV, shut off valve
SD, actuator
Theactuatorcontrolstheheatsupplyon/off.Inunpowered
modeSD230isopen.
SDM24, actuator
Theactuatorismodulatedandgivesthecorrectheat.SDMcan
besettoalwaysallowasmallleakageflowthrough.Thisisto
providequickheatsupplywhenadoorisopenedbutalsoto
provide a degree of frost protection.
VAT, adjustment tool for valve kit VOS, VOSP, VMO, VMOP
Withtheadjustmenttoolthewaterflowcanbeaccuratelyand
easilyset.
Fan heaters
TBVC/TBVCM
Theshutoffvalveconsistsofaballvalvewhichiseitheropen
or closed and is used to shut off the flow, when servicing for
example.
65
Water control
VR20/25
JVF20/25
TRV20/25
VR20/25
VR20/25
AV20/25
BPV10
AV20/25
AV20/25
JVF20/25
BPV10
JVF20/25
BPV10
TRV20/25
SD20
TRV20/25
SD20
T10/KRT
SD20
TVV20/25
T10/KRT
°C
230V ~
SD20
230V ~
TVV20/25
SD20
SD20
T10/KRT
T10/KRT
°C
°C
230V ~
VR 20/25, valve kit
For control of water flow to water heated air curtains.
Thevalvekitconsistsofthefollowing:
•AV20/25,stopvalve
•JVF20/25,adjustmentvalve
•TRV20/25,on/off3-waycontrolvalve
•BPV10,by-passvalve
•SD20,actuatoron/off230V~
Thestopvalve(AV20/25)consistsofaballvalvewhichis
either open or closed. It is used to turn the water flow off
andon.Thewaterflowcanbefine-tunedmanuallywiththe
adjustmentvalveandcanalsobecompletelyturnedoff.The
waterflowmaybereadoffthevalve.ThekvvalueforJVF20is
3,5andforJVF25itis5,5.
Ifthe3-wayvalve(TRV20/25)isclosed,theflowthroughthe
by-passvalve(BPV10)islowtoensurepresenceofwarmwater
intheheatingcoil.Thisleadstoinstantheatsupplywhen
neededandsomedegreeoffrostprotection.Theactuator
(SD20)workson/off.
Thevalvekitisavailablewithtwodifferentvalve
dimensions:VR20-DN20(3/4”)andVR25-DN25(1”).The
by-passvalvedimensionisDN10(3/8”).ToregulateVR20/25,
a suitable thermostat has to be added.
TVV20/25
°C
230V ~
TVV20/25, valves + SD20, actuator
TVV20/25,2-wayregulationvalveandSD20,actuatoron/
off provides a basic form of water regulation, without the
possibilityofadjustingorshuttingthewaterflowoff,e.g.
whenmakingmaintenance.Asuitablethermostatischosento
regulateTVV20/25andSD20.DN20/25.
TVV20/25, 2-way control valve
TVV20hasapipedimensionofDN20(3/4”)andTVV25of
DN25(1”).PressureclassPN16.
Maximumpressure2MPa(20bar).
MaximumpressuredropTVV20:100kPa(1bar)
MaximumpressuredropTVV25:62kPa(0,62bar)
Thekv-valueisadjustablein3steps:
TVV20:kv1,6,kv2,5andkv3,5
TVV25:kv2,5,kv4,0andkv5,5
TRV20/25, 3-way control valve
Ifa3-wayvalveispreferred,TRV20/25canbeusedinsteadof
TVV20/25.
SD20, actuator on/off 230V~
SD20regulatestheheatsupply.Workson/off.A5second
closing of the valve prevents sudden pressure changes in the
pipesystem.Protectionclass:IP40.
TE3434
Flexiblehose,length0,8metres,forwaterheatedunits(2is
neededforaunit)withexternalthread3/4”(DN20)atoneend
andcouplingnutinternalthread3/4”(DN20),ontheother.
TheseproductsshouldnotbeusedtogetherwithcontrolsystemSIRe.
66
Technical data
Symbols for model types
= normal design (no symbols), IPX0
= drip-proof design, IPX1
= splash-proof design, IPX4
= jet-proof design, IPX5
Protection classes for electrical material
Heat insulation, U-value
U = thermal transmittance value [W/m²°C]
U-values indicate the heat insulating capacity of a building
section.
Material
U-value
[W/m² °C]
IP, first figure
Protection against solid objects
0
No protection
Walls
1
Protection against solid objects ≥50 mm
New building
2
Protection against solid objects ≥12,5 mm
Wooden fascia with 15 cm insulation and plaster
0,27
3
Protection against solid objects ≥2,5 mm
Wooden fascia with 20 cm insulation and plaster
0,25
4
Protection against solid objects ≥1,0 mm
Wooden fascia with 25 cm insulation and plaster
0,22
5
Protection against dust
Brick fascia with 15 cm insulation and plaster
0,27
6
Dust-tight
Brick fascia with 20 cm insulation and plaster
0,24
Light concrete with 15 cm insulation
0,25
IP, second figure
Protection against water
Light concrete with 20 cm insulation
0,2
0
No protection
Sheet metal fascia with 5 cm insulation
0,8
1
Protection against vertically dripping water
Sheet metal fascia with 10 cm insulation
0,4
2
Protection against dripping water angled at max 15°
Sheet metal fascia with 15 cm insulation
0,3
3
Protection against sprinkled water
New construction for low energy house
0,18
4
Protection against spraying with water
Warehouse
0,3
5
Protection against water jets
One layer PVC (900 g)
5,0
6
Protection against heavy seas
Insulated hall (Thermohall)
0,6
7
Protection against short-term immersion in water
Older building
8
Protection against the effects of long-term
immersion in water
Single brick 12 cm
1,8
1 1/2 brick 18 cm
1,1
Light concrete block 20 cm
0,8
Light concrete block 30 cm
0,6
Concrete 15 cm
2,8
Concrete with 5 cm insulation
0,8
Concrete with 10 cm insulation
0,4
Frame wall with 5 cm insulation
0,8
Frame wall with 10 cm insulation
0,4
Frame wall with 15 cm insulation
0,3
New construction
0,3
How is sound measured?
Sound level is measured in decibels (dB). The dB is a
logarithmic unit used to describe a ratio. If the sound level is
increased by 10 dB, the result is twice as loud (as perceived by
human ear).
It is also useful to know that two equally strong sound
sources give an added sound level of 3 dB. Assume you have
two entrances with two air curtains in each entrance, all four
units with a sound level of 50 dB. The total sound level will
then be 56 dB. The first opening will have a total sound level of
53 dB plus an extra 3 dB from the other opening.
Roof
New building
Sheet metal pitched roof, with 20 cm insulation
0,24
Brick pitched roof, with 20 cm insulation
0,23
Older building
Points of reference – dB
Concrete beam frame 15 cm
2,8
0
The softest sound a person can hear
Concrete beam frame with 5 cm insulation
0,8
10
Normal breathing
Concrete beam frame with 10 cm insulation
0,4
30
Recommended max. level for bedrooms
Light concrete 20 cm
0,8
40
Quiet office, library
Light concrete 30 cm
0,6
50
Large office
Sheet metal roof, uninsulated
4,0
Sheet metal roof with 5 cm insulation
0,8
60
Normal conversation
Sheet metal roof with 10 cm insulation
0,6
80
Ringing telephone
Sheet metal roof with 25 cm insulation
0,2
85
Noisy restaurant
Windows
110
Shouting in ear
120
The threshold of pain
The sound level is stated for most of our product in the mini
catalogue. Our sound measurements are done according to
international standards BS 848, AMCA standard 210-85 and
DIN 24 163, (the distance to the product* 5 metres, directional
factor 2, equivalent absorption area 200 m²).
*) For fan heaters Tiger, Cat and Panther as well as convector
PF, the distance to the product is 3 metres.
New building
1+1 pane window (1 outer pane and 1 insulated pane)
2,5
2 pane window (2 insulated panes)
2,7
2+1 pane window (1 outer pane and 2 insulated panes)
1,0
3 pane window (3 insulated panes)
1,2
Energy class A
0,9
Energy class B
1,0
Energy class C
1,1
Energy class D
1,2
Energy class E
1,3
Energy class F
1,4
Energy class G
1,5
Older building
1 pane window
5,0
2 pane window
3,0
3 pane window
2,0
3 pane window insulation pane
1,8
67
Frico AB
Box 102, SE-433 22 Partille
Sweden
T
+ 46 31 336 86 00
F
+ 46 31 26 28 60
[email protected] • www.frico.se