viesmann - Viessmann Direct
Transcription
viesmann - Viessmann Direct
Installation and service instructions VIESMANN for contractors Vitocom 100 Type LAN1 Communication interface for remote monitoring and control of heating systems via the internet, for the following user interfaces: ■ Vitotrol app ■ Vitodata 100 (www.vitodata100.com) For applicability, see the last page VITOCOM 100 5619 832 GB 03/2012 Please keep safe. Safety instructions Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained Danger This symbol warns against the risk of injury. ! Please note This symbol warns against the risk of material losses and environmental pollution. Note Details identified by the word "Note" contain additional information. ■ all current safety regulations as defined by DIN, EN, DVGW, TRGI, TRF, VDE and all locally applicable standards, ■ Gas Safety (Installation & Use) Regulations – the appropriate Building Regulation either the Building regulations, the Building Regulation (Scotland), Building Regulations (Northern Ireland), – the Water Fittings Regulation or Water Bylaws in Scotland, – the current I.E.E. Wiring Regulations. Target group If you smell gas Regulations Observe the following when working on this system ■ all legal instructions regarding the prevention of accidents, ■ all legal instructions regarding environmental protection, ■ the Code of Practice of relevant trade associations, 2 Danger Escaping gas can lead to explosions which may result in serious injury. ■ Never smoke. Prevent naked flames and sparks. Never switch lights or electrical appliances ON or OFF. ■ Close the gas shut-off valve. ■ Open windows and doors. ■ Remove all people from the danger zone. ■ Notify your gas or electricity supplier from outside the building. ■ Shut off the electricity supply to the building from a safe place (outside the building). 5619 832 GB These instructions are exclusively designed for qualified personnel. ■ Work on gas equipment must only be carried out by a qualified gas fitter. ■ Work on electrical equipment must only be carried out by a qualified electrician. ■ The system must be commissioned by the system installer or a qualified person authorised by the installer. Safety instructions Safety instructions (cont.) If you smell flue gas Danger Flue gas can lead to life-threatening poisoning. ■ Shut down the heating system. ■ Ventilate the boiler room. ■ Close all doors leading to the living space. Working on the system ■ When using gas as fuel, also close the main gas shut-off valve and safeguard against unauthorised reopening. ■ Isolate the system from the power supply and check that it is no longer 'live', e.g. by removing a separate fuse or by means of a main isolator. ■ Safeguard the system against unauthorised reconnection. ! Ancillary components, spare and wearing parts ! Please note Spare and wearing parts which have not been tested together with the heating system can compromise its function. Installing non-authorised components and non-approved modifications/conversion can compromise safety and may invalidate our warranty. For replacements, use only original spare parts from Viessmann or those which are approved by Viessmann. Please note Electronic modules can be damaged by electro-static discharges. Touch earthed objects, such as heating or water pipes, to discharge static loads. Repair work Please note Repairing components which fulfil a safety function can compromise the safe operation of your heating system. Replace faulty components only with original Viessmann spare parts. 5619 832 GB ! 3 Index Index Installation instructions Operational reliability and liability Operational reliability............................................................................................ Liability................................................................................................................. 6 6 Preparing for installation System requirements........................................................................................... 7 Operation with the Vitotrol app............................................................................. 8 Operation with Vitodata 100 user interface.......................................................... 10 Checking network settings................................................................................... 11 Installation sequence Sequence overview.............................................................................................. Installing wall mounting bracket........................................................................... Removing cover................................................................................................... Overview of connections...................................................................................... Installing communication module in the Vitotronic control unit............................. Connecting the Vitocom 100 to the Vitotronic control unit................................... Connecting to Vitodens 3..., type B3.................................................................... Connecting to network (LAN)............................................................................... Inserting Vitocom 100 in wall mounting bracket................................................... Power supply........................................................................................................ 12 12 14 14 15 15 16 17 18 18 Service instructions Commissioning Display and control elements............................................................................... Switching on the Vitocom 100.............................................................................. Checking the LON connection to the Vitotronic control unit................................. Registering user and setting up heating system.................................................. Function test......................................................................................................... 19 21 22 23 25 Service functions Enabling maintenance.......................................................................................... 26 Regular function testing........................................................................................ 26 Return to delivered condition................................................................................ 26 Parts lists Ordering parts...................................................................................................... 28 Parts..................................................................................................................... 28 4 5619 832 GB Troubleshooting Troubleshooting measures................................................................................... 27 Index Index (cont.) Specification....................................................................................................... 30 Certificates Declaration of conformity...................................................................................... 31 5619 832 GB Keyword index.................................................................................................... 32 5 Operational reliability and liability Operational reliability ! Please note The Vitocom 100 establishes communication via the internet between the connected Vitotronic control unit and the user interfaces, e.g. Vitodata 100 or Vitotrol app. Technical details on the control functions and the messages transferred should be taken from the installation and service instructions for the Vitotronic control unit or the heat source. Note The radio reception of the Vitocom 100 differs depending on the user interface. The respective range of functions will only be available if the following conditions are met: ■ The Vitotronic control units and the Vitocom 100 must be connected and configured correctly. ■ The Vitocom 100 is connected to the internet via a DSL router. ■ Internet access must be available at all times. ■ User registration has been carried out (see page 23). ■ In order to send messages via the Vitodata 100, the recipients must be set up correctly on the Vitodata server. ■ To ensure that messages can still be transferred during mains failure, we recommend connecting the Vitocom 100 and DSL router to the power supply via a UPS. Note ■ The heating system and the functionality of the message paths must be checked at regular intervals. ■ For further improvement of the operational reliability of the heating system, we recommend implementing supplementary measures, e.g. frost protection or monitoring for water damage. Liability 6 Viessmann accepts no liability for SMS or email services, which are provided by network operators. The terms and conditions of the respective network operators apply in this context. 5619 832 GB Viessmann accepts no liability for loss of profit, unattained savings, or other direct or indirect consequential losses resulting from use of the Vitocom 100, the Vitodata internet services or the software, or for damage resulting from inappropriate use. The Viessmann General Terms and Conditions apply, which are included in each current Viessmann pricelist. Preparing for installation System requirements Heating system ■ The Vitocom 100, type LAN1 can be used for one single boiler system with Vitotronic control unit, with or without heating circuits downstream. ■ The max. number of devices (LON subscribers) comprising boiler and heating circuit control units is 30. Installation Supported heat sources For an up to date list of supported heat sources, see Online help Vitodata 100 (www.vitodata100.com). IP network 5619 832 GB ■ DSL router with a free LAN connection (on site). ■ Internet connection with "flat rate" (flat rate tariff independent of time and data volume) with high level of availability, i.e. the Vitocom 100 is permanently connected with the Vitodata server. ■ Have dynamic IP addressing (DHCP) in the network (LAN) checked on site, and if required set up, by an IT expert prior to commissioning. ■ Determine the routing and safety parameters in the IP network (LAN) so that port 80 and port 443 are approved for direct outgoing connections. Prior to commissioning have this checked on site by an IT expert and, if necessary, set up. Note During operation, the Vitocom 100 establishes a secure internet connection to the Vitodata server. The Vitocom 100 cannot be connected to any other servers. User account on the Vitodata server Operating a Vitocom 100 and using the Vitotrol app require a valid user account on the Vitodata server. Registration is possible either using the Vitodata 100 user interface or the Vitotrol app (see page 23). Operator unit for the Vitotrol app Recommended mobile end device (for operating system, see App Store): ■ iPhone 4 and iPhone 4S ■ iPad and iPad2 ■ iPod Touch with retina display 7 Preparing for installation System requirements (cont.) Operator unit for the Vitodata 100 user interface Recipients Computer equipped with the following: ■ Windows XP, Windows Vista, Windows 7 operating system ■ Web browser Microsoft Internet Explorer, Version 8.0 or Mozilla Firefox, Version 3.0 ■ 'Live' internet connection ■ End device (e.g. computer) for receiving email. ■ Mobile phone for receiving SMS (only with internet service "Vitodata 100 fault management"). ■ Fax for receiving messages (only with internet service "Vitodata 100 fault management"). Operation with the Vitotrol app For remote control of Viessmann heating systems with Vitotronic control units via IP networks. B C D E H A F G 8 G Vitodata server H Mobile end device (see page 7) with the Vitotrol app: ■ Remote control of the heating system. ■ Message retrieval. 5619 832 GB A Heat source with control unit (see page 7) B LON cable C Vitocom 100 D IP network (on site) E DSL router (on site) F Secure internet connection to the Vitodata server Preparing for installation Operation with the Vitotrol app (cont.) Functions ■ Setting set temperatures. ■ Setting operating programs. ■ Scanning operating conditions and temperatures Note ■ The Vitotrol app only allows the user to access one system at a time using a single end device. ■ For further information on the Vitotrol app, see www.viessmann.de/vitotrolapp. Note Heating system messages are only displayed if the Vitotrol app is enabled on the mobile end device. Content of messages ■ Notification type ■ Message code ■ Message text Heat source installation and service instructions Forwarding messages 5619 832 GB Pending messages in the heating system, e.g. sensor or burner faults are transferred via LON to the Vitocom 100. The Vitocom 100 transmits these messages to the Vitodata server. The Vitotrol app scans the status of the heating system cyclically and displays the messages. 9 Installation Vitotrol app control functions Preparing for installation Operation with Vitodata 100 user interface For remote monitoring and control of Viessmann heating systems with Vitotronic control units via IP networks. B C D E H A F K G A Heat source with control unit (see page 7) B LON cable C Vitocom 100 D IP network (on site) E DSL router (on site) F Secure internet connection to the Vitodata server G Vitodata server, registration and log-in via www.vitodata100.com H Computer: ■ Remote control of the heating system via the Vitodata 100 user interface ■ Receipt of messages via email L K Fax for receiving messages (only with internet service "Vitodata 100 fault management") L Mobile phone for receiving messages via SMS (only with internet service "Vitodata 100 fault management") Functions ■ Setting set temperature values, heating curve slope and level. ■ Setting operating programs, holiday programs and switching times. 10 ■ Setting party or economy mode. ■ Scanning operating conditions and temperatures 5619 832 GB Vitodata 100 control functions Preparing for installation Operation with Vitodata 100 user interface (cont.) Pending messages in the heating system, e.g. sensor or burner faults, are transferred via LON to the Vitocom 100. The Vitocom 100 transmits these messages to the Vitodata server. The messages can be displayed on the Vitodata 100 user interface. If recipients (email, fax or SMS) are stored on the Vitodata server, the messages are automatically forwarded to these recipients. Content of messages ■ Date and time ■ System description ■ Message text ■ Fault code ■ System status Heat source installation and service instructions Installation Forwarding messages Note The Vitodata fault management internet service is required for forwarding messages by fax or SMS (Vitocom 100 standard delivery, free of charge for 3 years). Checking network settings 5619 832 GB Have the following settings on the DSL router checked, and if necessary adjusted, by an IT expert: ■ Dynamic IP addressing (DHCP) must be enabled. ■ Port 80 and port 443 must be approved for outgoing connections. 11 Installation sequence Sequence overview Sequence Installation 1 Check system requirements. 2 3 Fit wall mounting bracket. Install communication module in Vitotronic control unit. 4 Connect Vitocom 100 to the Vitotronic control unit. 5 Connect Vitocom 100 to Vitodens 3..., type B3. 6 Connect Vitocom 100 to network (LAN). 7 Insert Vitocom 100 in wall mounting bracket. 8 Power supply Commissioning 9 Switch on Vitocom 100. 10 Check LON connection to the Vitotronic control unit. 11 Register user and set up heating system. ■ Operation with the Vitotrol app ■ Operation with the Vitodata 100 user interface 12 Trigger heating system fault and check reporting. Responsibility Page Heating contractor/IT 7 expert Heating contractor 12 Heating contractor See communication module installation instrucHeating contractor tions System user 16 Heating contractor/IT expert Heating contractor 17 18 Heating contractor 18 Heating contractor Heating contractor 21 22 Heating contractor/ system user 23 24 Heating contractor 25 Installing wall mounting bracket Please note The installation site must be dry and free from the risk of frost. Safeguard ambient temperatures between 0 and 40 °C. Note When selecting the installation site, bear in mind the length of the connecting cables (standard delivery). 12 5619 832 GB ! Installation sequence Installing wall mounting bracket (cont.) 5619 832 GB Installation Connecting cables Length LAN connecting cable (may 2m be extended on site by IT expert) LON connecting cable, red 7m (may be extended with accessory, see communication module installation instructions) Connecting cable for plug-in Approx. power supply unit 1.9 m 13 Installation sequence Removing cover Refit in reverse order. Overview of connections § $ ! Plug-in power supply unit connection, 5 V–, internal +, external –, min. 1.6 A (see page 21) 14 ) aÖ § Service interface: Do not make any on-site connections. 5619 832 GB ! Installation sequence Overview of connections (cont.) $ RJ 45 connector for LON connection cable to DSL router (see page 17 and "Explanation of displays" see page 20) ) LON terminator, is enabled in the delivered condition (position of switch left, do not adjust) aÖ RJ 45 connector for LON connection cable (red) to the Vitotronic control unit (see communication module installation instructions) Installation Installing communication module in the Vitotronic control unit Communication module installation instructions Connecting the Vitocom 100 to the Vitotronic control unit 5619 832 GB Communication module installation instructions 15 Installation sequence Connecting to Vitodens 3..., type B3 Vitodens 300-W, type B3HA A 1. Route cable with RJ 45 LON coupling A downwards out of the control unit support. 2. Connect LON connecting cable to the LON coupling of the Vitodens and to the LON connection aÖ of the Vitocom 100. Vitodens 333-F, type B3TA and Vitodens 343-F, type B3UA 5619 832 GB Note LON coupling A can be mounted on the left or right, as well as below the feedthrough openings on the sides. 16 Installation sequence Connecting to Vitodens 3..., type B3 (cont.) Installation A Connect LON connecting cable to the LON coupling of the Vitodens and to the LON connection aÖ of the Vitocom 100. Connecting to network (LAN) 1. Plug LAN connecting cable into LAN connection $ of the Vitocom 100. 2. Plug the free end of the LAN connecting cable into a LAN connection on the DSL router or at the on-site network installation. 5619 832 GB DSL router documentation (on site) 17 Installation sequence Inserting Vitocom 100 in wall mounting bracket Power supply 5619 832 GB See chapter "Switching on the Vitocom 100" on page 21. 18 Commissioning Display and control elements Without cover Remove cover, see page 14. A "4" "5" No function IP connection status (green and yellow LED) Operating status display (green and red LED) Display for data transfer service interface (green LED) Service "2" "3" 5619 832 GB A Type plate "T1" Maintenance button (see page 26) "T2" No function "T3" LON key, only when integrating the Vitocom 100 into a BMS (send service PIN). "T4" Reset button (see page 26) "1" LON service indicator (green LED) 19 Commissioning Display and control elements (cont.) With cover "T1" Maintenance button (see page 26) "3" IP connection status (green and yellow LED) "4" Operating status display (green and red LED) 3 4 T1 Explanation of displays 5619 832 GB LON service indicator "1" Flashes green LON subscriber check successful (see page 22). IP State of connection "3" Flashes yellow/illu- Establishing a connection (see page 21), or connection fault minates yellow (see page 27), to the DSL router (DHCP server), internet or Vitodata server. Illuminates green Connection to the Vitodata server established. Flashes green Data transfer between the Vitocom 100 and Vitodata server enabled. Operating status display "4" Illuminates red Service enabled (see page 26). Flashes red Heating system fault. Flashes green lon- Fault when initialising the Vitocom 100 (see page 27). ger than 3 min Illuminates green "Standard mode", no heating system or Vitocom 100 fault. 20 Commissioning Display and control elements (cont.) Flashes green Flashes green quickly The Vitocom 100 will initialise after the power supply unit is plugged in or the reset button is pressed. Software update is being installed. The device must not be isolated from the mains. Switching on the Vitocom 100 ! Please note If the connection values of the power supply unit do not match the power consumption of the Vitocom 100, this can lead to interruption of operations and damage to the power supply or the Vitocom 100. Only use the power supply unit supplied. 1. Plug LV side of the plug-in power supply unit into terminal ! (see page 14) of the Vitocom 100. 2. Plug power supply unit into standard 230 V~ socket. Vitocom 100 is initialised (see "Initialisation"). When the Vitocom 100 is initialising, the following processes run in sequence: 5619 832 GB 1. The Vitocom 100 starts and loads the internal operating software The operating status display "4" (see page 19) flashes green after max. 40 s. After a few minutes, operating status display "4" illuminates green. 2. Connect with the Vitodata server IP connection status display "3" (see page 19) shows the procedure for establishing the connection: ■ Flashes yellow slowly: The Vitocom 100 is integrated into the on-site IP network (obtain IP address of DHCP server). ■ Flashes yellow quickly: Internet connection is being established. ■ Illuminates yellow: Connection to the Vitodata server is being established. ■ Illuminates green: Secure connection to the Vitodata server is established. 21 Service Initialisation Commissioning Switching on the Vitocom 100 (cont.) 3. Connect with the Vitotronic control unit via LON The Vitocom 100 creates a list of all LON subscribers. Note It may take several minutes to establish the connection via LON. Initialisation not successful If a fault occurs during initialisation, this is indicated by the associated LED indicators. For troubleshooting measures, see page 27. Initialisation successful The Vitocom 100 is ready for operation. The following LED indicators illuminate green: operating status display "4" and IP connection status "3". Checking the LON connection to the Vitotronic control unit To check the LON connection, carry out LON subscriber check on the Vitotronic control unit. Requirements: ■ The Vitocom 100 is connected to the Vitotronic control unit via LON. ■ All devices are switched on. ■ LON subscriber numbers are assigned to the Vitotronic control units. ■ The Vitotronic control unit is the fault manager. Performing a subscriber check ■ Heat source installation and service instructions or ■ Vitotronic control unit service instructions Note If the subscriber check was successful, LON service display "1" flashes green (see page 19) at the Vitocom 100 for approx. 1 min and "Check OK" appears in the Vitotronic display. 5619 832 GB Note The Vitocom 100 has the LON subscriber number "99" (fixed). 22 Commissioning Checking the LON connection to the Vitotronic… (cont.) Updating LON subscriber list In the following cases, the LON subscriber list in the Vitocom 100 must be updated: ■ New LON subscriber installed. ■ LON subscriber has been removed. ■ The LON communication module of an existing subscriber has been replaced. To update the LON subscriber list, hold down reset button "T4" (see page 19) for approx. 10 s. Note If the reset button is held down for approx. 30 s, the Vitocom 100 is returned to its delivered condition. Registering user and setting up heating system For operation of the heating system via the Vitodata 100 user interface and the Vitotrol app, a user account must be created on the Vitodata server and the heating system must be set up. For this, carry out one-off user registration. Via the Vitotrol app 2. Press on "Create access" and complete all fields on the registration form. 4. Open the email in your inbox and follow the activation link provided to complete the registration. The user account and the system are fully set up. 5619 832 GB Note ■ In the "Password" field, assign a new password (min. 6 characters: a..z, A..Z, 0..9) and confirm this in the "Enter password again" field. ■ "Connection data" can be found on the Vitocom 100 type plate (see page 19). 3. Press "Register". An email is sent (Subject: "Your registration for the Vitodata 100") is sent with an activation link to the previously specified email address. 23 Service 1. Start the Vitotrol app. Commissioning Registering user and setting up heating system (cont.) 5. In the Vitotrol app, press "Log in" and log in with the following access details: User name: Password: Vitotrol app online help Note It is also possible to register via the Vitodata 100 user interface, using the access details specified. Email address specified Password indicated The heating system can be operated via the Vitotrol app. Via the Vitodata 100 user interface Register user 1. Open with internet browser "http://www.vitodata100.com". 2. On the start page, press "Register" and complete all fields on the registration form. Note In the "Password" field, assign a new password (min. 6 characters: a..z, A..Z, 0..9) and confirm this in the "Enter password again" field. 6. Open the email in your inbox and follow the activation link provided to complete the registration. The user registration is complete. The user account is fully set up. Setting up the heating system 1. Open with internet browser "http://www.vitodata100.com" and log in to the Vitodata server. User name: Password: 3. Press "Next". Email address specified Password indicated 4. Check and enter the confirmation code from the graphic displayed. Tick to accept the terms of use. 5619 832 GB 5. Press "Register". An email is sent (Subject: "Your registration for the Vitodata 100") with an activation link to the previously specified email address. 24 Commissioning Registering user and setting up heating system (cont.) 2. Select "Create a new system", select system type "Vitocom 100, type LAN1" and enter "Connection data". Vitodata 100 online help Note The manufacturer's details can be found on the Vitocom 100 type plate (see page 19). Function test 1. Simulate a fault in the heating system, e.g. sensor fault. Heat source service instructions 2. Check the following: ■ Operating status display "4" (see page 19) flashes red. ■ The fault message is displayed in the Vitotrol app and sent to the recipients stored in the Vitodata 100. 5619 832 GB Service Note ■ If a fault is rectified, this is confirmed with a message. ■ If the fault is not rectified, then a repeat message is sent on the 3 days following. 25 Service functions Enabling maintenance With this function, the transfer of messages from the heating system to the Vitodata server is suppressed, e.g. for maintenance work. 1. Prior to maintenance work on the heating system, briefly press the maintenance button (approx. 1 s). ■ Operating status display "4" (see page 19) illuminates red. ■ The message "Maintenance button ON" is displayed in the Vitotrol app and sent to the recipients stored in the Vitodata 100. 2. Briefly press the maintenance button again once the maintenance work has been carried out (approx. 1 s). ■ The operating status display "4" (see page 19) changes from red to green (if no fault has developed in the heating system). ■ The message "Maintenance button OFF" is displayed in the Vitotrol app and sent to the recipients stored in the Vitodata 100. Note The maintenance function is automatically reset after 8 h. Note If the maintenance button was not pressed before maintenance work, then a fault message may be sent, depending on the activity. Regular function testing The functionality of the message paths must be checked at regular intervals (see "Function testing" on page 25). Press reset button "T4" (see page 19) (approx. 30 s), until operating status display "4" and IP connection status display "3" go out. The following processes are performed: ■ The Vitocom 100 LON subscriber list is updated. ■ The Vitocom 100 is newly initialised (see page 21). 26 5619 832 GB Return to delivered condition Troubleshooting Troubleshooting measures Faults on the Vitocom 100 are indicated by various LED indicators (see page 19). Measures Check the Vitocom 100 power supply. Check configuration of the recipients in the Vitodata 100. Check LON connecting cables. 5619 832 GB Faults without LED indicator Fault All displays on the Vitocom 100 are off. The messages are displayed in the Vitotrol app, but not sent to the recipients. The Vitocom 100 reports "subscriber failure". 27 Service Faults with LED indicator Type of fault and measures IP connection status"3" Flashes yellow slowly IP address could not be obtained. ■ Check LAN connecting cable. ■ At the router, check whether DHCP has been set, check other network settings. ■ If necessary, replace the Vitocom 100. Flashes yellow quickly IP address obtained, but no internet connection. ■ Check internet connection using another LAN subscriber, e.g. laptop. ■ If no internet connection is possible even with another LAN subscriber, have the network settings checked at the DSL router by an IT expert. Illuminates yellow Internet connection available, but the Vitodata server cannot be reached. Disconnect plug-in power supply unit and reconnect again after approx. 15 s. Connection attempt is repeated (see page 21). Operating status display "4" Flashes green longer Fault when initialising the Vitocom 100 than 3 min ■ Disconnect plug-in power supply unit and reconnect again after approx. 15 s. ■ If necessary, replace the Vitocom 100. Parts lists Ordering parts The following information is required: ■ Serial no. (see Vitocom 100 type plate A) ■ Position number of the required part (from this parts list) Standard parts are available from your local supplier. Parts Vitocom 100 Casing LON communication module LAN connecting cable LON connecting cable, red Plug -in power supply unit 5619 832 GB 0001 0002 0003 0004 0005 0006 28 Parts lists Parts (cont.) A 0001 0002 Service 0003 5619 832 GB 0004 0005 0006 A Vitocom 100 type plate (under the cover) 29 Specification Specification Vitocom 100, type LAN1 Operating voltage Rated current Power consumption Protection class Protection Permiss. ambient temperature ■ during operation ■ during storage and transport 0 to +55 °C Installation in living spaces and boiler rooms (standard ambient conditions) −20 to +85 °C 100 to 240 V~ 50/60 Hz 0.25 A 5 V– 1.6 A II 0 to +40 °C -40 to +70 °C 5619 832 GB Plug-in power supply unit Rated voltage Rated frequency Rated current Output voltage Output current Safety category Permiss. ambient temperature ■ during operation ■ during storage and transport 5 V– 1.6 A 8W II IP 30 to EN 60 529 30 Certificates Declaration of conformity We, Viessmann Werke GmbH & Co KG, D-35107 Allendorf, declare as sole responsible body that the product Vitocom 100, type LAN1 complies with the following standards: EN 50090-2-2 EN 55011 EN 55014-1 EN 55014-2 EN 55022 EN 55024 EN 60335-1 EN 61000-3-2 EN 62233 This product is _ designated in accordance with the terms of the following Directives: 2006/95/EC Allendorf, 04 October 2011 2004/108/EC Viessmann Werke GmbH&Co KG 5619 832 GB Service Authorised signatory Manfred Sommer 31 Keyword index Keyword index B Browser................................................8 C Cascade control unit............................7 Check connection..............................12 Checking connection via LON............22 Commissioning..................................19 Communication module, installation...............................................12, 15 Confirmation code..............................24 Connecting cable for plug-in power supply unit................................................13 Connection ■ Plug-in power supply unit...............14 ■ To network (LAN).....................12, 17 ■ To the Vitotronic control unit.....12, 15 Connection, establishing....................20 Connection fault.................................20 Connections.......................................14 Connection values of the power supply unit.....................................................21 Control elements................................19 D Delivered condition, returning to........26 DHCP.......................................7, 11, 27 Display elements................................19 Display for data transfer service interface....................................................19 DSL router..................................7, 8, 11 Dynamic IP addressing........................7 E Economy mode..................................10 Email....................................................6 32 F Fault ■ Heating system...............................20 ■ On the Vitocom 100........................20 Fault indicator..............................26, 27 Fault manager....................................22 Fault message...................................26 Fax.....................................................10 Fax reception.......................................8 Forwarding messages....................9, 11 Frost protection....................................6 Functions ■ With the Vitotrol app.........................9 ■ With Vitodata 100...........................10 Function test......................................25 G General terms and conditions............24 General Terms and Conditions............6 H Heating curve.....................................10 Heating system, setting up...........23, 24 Heating system set up.......................12 Heat sources........................................7 Holiday program.................................10 HTTPS protocol.............................8, 10 I Initialisation..................................21, 22 Installation of wall mounting bracket. .12 Installation site...................................12 Internet access.....................................6 Internet browser...................................8 Internet connection, establishing.......21 iPad......................................................7 IP address..........................................11 IP addressing.......................................7 IP connection status...19, 20, 21, 26, 27 iPhone..................................................7 IP network......................................8, 10 iPod......................................................7 5619 832 GB A Access details....................................24 Activation link...............................23, 24 Ambient temperature...................12, 30 Keyword index Keyword index (cont.) L LAN connecting cable............13, 17, 28 LAN connection............................15, 17 Liability.................................................6 LON ■ Checking the connection................22 ■ Making the connection....................22 LON cable......................................8, 10 LON communication module..............23 LON connecting cable..................13, 28 LON connection.................................15 LON key.............................................19 LON service display...........................22 LON service indicator.........................19 LON subscriber....................................7 LON subscriber check..................20, 22 LON subscriber list.......................23, 26 LON subscriber number.....................22 LON terminator..................................15 M Maintenance and fault indicator.........26 Maintenance button...............19, 20, 26 Malfunction.........................................27 Measures for troubleshooting............27 Message code................................9, 11 Messages, forwarding ...................9, 11 Message text..................................9, 11 Mobile phone.....................................10 Mounting............................................12 5619 832 GB N Network..........................................8, 10 Network installation............................17 Network operator.................................6 Network settings................................11 Notification type.............................9, 11 O Obtain IP address..............................21 Online help, Vitodata 100...................25 Operating conditions, scanning............9 Operating program.........................9, 10 Operating software.............................21 Operating status display........19, 20, 26 Operating system.............................7, 8 Operating voltage...............................30 Operation ■ With the Vitotrol app.........................8 ■ With Vitodata 100 user interface....10 Operational reliability...........................6 Operator unit ■ for the Vitodata 100 user interface. . .8 ■ for the Vitotrol app............................7 Output current....................................30 Output voltage....................................30 Overview of connections....................14 P Parts...................................................28 Parts list.............................................28 Party mode.........................................10 Password ■ For the Vitodata 100 user interface 24 ■ For the Vitotrol app.........................24 Plug-in power supply unit...................28 ■ Ambient temperature......................30 ■ Output current.................................30 ■ Output voltage................................30 ■ Rated current..................................30 ■ Rated frequency.............................30 ■ Rated voltage.................................30 ■ Safety category...............................30 Port 443.........................................7, 11 Port 80...........................................7, 11 Power supply.....................................18 Protection...........................................30 Protection class..................................30 R Rated current.....................................30 Rated frequency.................................30 Rated voltage.....................................30 Recipients......................................6, 11 Registering user.................................23 Registration form..........................23, 24 33 Keyword index Keyword index (cont.) Remote control...............................8, 10 Remote monitoring.........................8, 10 Reporting system, checking of...........12 Requirements.......................................6 Reset..................................................26 Reset button...........................19, 23, 26 U User, registering.................................12 User, registration................................24 User account........................................7 User interface.......................................6 User name ■ For the Vitodata 100 user interface 24 ■ For the Vitotrol app.........................24 V Vitodata 100 user interface................10 Vitotrol app.........................................23 Vitotronic control unit.....................8, 10 W Wall mounting bracket, installation....12 Web browser........................................8 Web server...........................8, 9, 10, 11 5619 832 GB S Safety category..................................30 Safety parameters................................7 Scan operating condition...................10 Secure connection.........................8, 10 Serial no.............................................28 Service functions................................26 Service interface................................14 Set temperatures.................................9 Set temperature value........................10 Single boiler system.............................7 Smartphone.........................................8 SMS.....................................................6 Spare parts........................................28 Specification.......................................30 Subscriber check...............................22 Subscriber list..............................23, 26 Switching times..................................10 System, setting up.......................23, 24 System requirements ■ Heating system.................................7 ■ IP network.........................................7 System set up ...................................12 T Tablet PC.............................................8 Terms and Conditions..........................6 Troubleshooting.................................27 Type plate..........................................19 34 35 5619 832 GB 7494755 Viessmann Werke GmbH&Co KG D-35107 Allendorf Telephone: +49 6452 70-0 Fax: +49 6452 70-2780 www.viessmann.com 36 Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: +44 1952 675000 Fax: +44 1952 675040 E-mail: [email protected] Subject to technical modifications. Serial No.: 7501472 5619 832 GB Applicability