Reviewed
:
Jason Wu
PREPARE BY:
AXIOMTEK CO., LTD
5F. 2, LANE 235, PAO CHIAO ROAD,
HSIH TIEN, TAIPEI HSIEN, TAIWAN, R.O.C.
TEL : 886-2-29174550
FAX: 886-2-29147454
Table of Contents
RELEASE HISTORY..............................................................................................................................1
SUMMARY OF DVT RESULTS ...........................................................................................................2
CHAPTER 1 CPU CARD ONBOARD FUNCTION TESTING........................................................1
CHAPTER 2 O.S & ADD_ON CARD COMPATIBILITY TESTING .............................................3
I.
II.
III.
SYSTEM CONFIGURATION:.......................................................................................................................3
O.S. (OPERATING SYSTEM) INSTALLATION TEST: ..................................................................................3
ADD-ON CARD .....................................................................................................................................4
CHAPTER 3 RELIABILITY ................................................................................................................5
I.
II.
III.
OPERATING TEMPERATURE AND HUMIDITY TEST...................................................................................5
LOW/HIGH TEMPERATURE & ROOM TEMPERATURE COLD START TEST ...............................................7
TEMPERATURE/THERMAL PROFILE TEST ..........................................................................................10
CHAPTER 4 VIBRATION TESTING ...............................................................................................12
I. EUT TEST ....................................................................................................................................................12
II. TEST EQUIPMENT .......................................................................................................................................12
III. TEST CONDITION .......................................................................................................................................12
IV. TEST CRITERIA .........................................................................................................................................13
V. TEST RESULT..............................................................................................................................................13
CHAPTER 5 DROP TESTING ...........................................................................................................16
I. EUT TEST ....................................................................................................................................................16
II. TEST EQUIPMENT .......................................................................................................................................16
III. PACKING CONDITION ................................................................................................................................16
IV. DROPPING CONDITION ..............................................................................................................................16
V. TEST CRITERIA ...........................................................................................................................................17
VI. TEST RESULT ............................................................................................................................................17
APPENDIX 1 : APPROVED PROBLEM SUMMARY .......................................................................1
Release History
Report Version : A1.0
1. New product(First Edition)
Test Report
Summary Of DVT Results
Test Item
Description
Test Result
System Function testing
PASS
OS & Addon card Compatibilty testing
PASS
Reliability
Include
PASS
(1).Temp/Humidity test and
(2).Temp/Thermal measure
(3).Room/low/high Temp cold start
Vibration test
PASS
Drop test
PASS
Note:Product meeting the DVT requirement should not have any “Fatal” or “Serious” problem
remaining opened.
2
P1123-671
Test Report
CHAPTER 1 CPU Card Onboard Function Testing
NUM
Approve Item
Test Result
PASS FAIL N/A
1
CPU
ˇ
2
Memory Socket
ˇ
3
IDE Device Interface
ˇ
4
HDD Driver Bay
ˇ
5
HDD Power Cable
ˇ
6
External FDD Interface Connector
ˇ
7
External IDE Interface Connector
ˇ
8
External +5V &12V Output
ˇ
Remark
Connector
9
VGA CRT Connector
ˇ
10
COM1
ˇ
11
COM2(RS232/422/485)
ˇ
12
CMO3
ˇ
13
COM4
ˇ
14
Parallel Port(PRN)
ˇ
15
PS2 Keyboard Connect(K/B)
ˇ
16
PS/2 Mouse Connect(MOUSE)
ˇ
17
Disk-On-Chip
ˇ
SBC83671
18
Watchdog Function
ˇ
SBC83671
19
LAN RJ-45 (NET)
ˇ
20
Power Connect & Switch
ˇ
21
DIO(4-Channel Digital Input/Output)
ˇ
22
ELO Touch Screen (COM3)
ˇ
23
LCD
ˇ
P1123-671
Touch screen used
1
Test Report
2
Test Result
PASS FAIL N/A
NUM
Approve Item
24
PCI-1 Slot(Riser card,P1120 Vre.A1)
ˇ
25
ISA Slot(Riser card,P1120 Vre.A1)
ˇ
26
CPU Cooler
ˇ
27
System FAN
ˇ
28
Mechanism
ˇ
Remark
P1123-671
Test Report
CHAPTER 2 O.S & Add_on Card Compatibility Testing
I.
System Configuration:
Item
Description
Item
Description
CPU Type
PIII-1.4G
DRAM
P1123-671
Sansung 512MB x 1
System BIOS
B10.1F.0
HDD
Toshiba 20GB
FDD
Mitsumi D353T6
Monitor
ADI 15”
Mouse
Logitech M-S34 PS/2
CD_ROM
ASUS 52X
K/B Keyboard
Sampo 101 Key
Model
II. O.S. (Operating System) Installation Test:
O.S.
Version
MS-DOS
V6.22
MS-Windows NT
Workstation
(Chinese Version)
V4.0
SP6A
MS-Windows 95
(English Version)
(Chinese Version)
4.00.95
4.00.95B
MS-Windows 98
(English Version)
(Japanese Version)
(Chinese Version)
MS-Windows ME
(English Version)
(Chinese Version)
4.10.98SE
Windows 2000
Professional
(English Version)
(Chinese Version)
Windows 2000 Server
(English Version)
(Chinese Version)
5.00.2195
SP3
P1123-671
4.90.3000
5.00.2195
SP3
Feature Test
Result
Installation
Boot, Warm Boot And Cold Boot
Suspend and Resume
Installation
Boot, Login, Shutdown, Reboot
Suspend and Resume
Pass
Installation
Start Win, Enter DOS, Exit DOS,
Exit Win
Suspend and Resume
Installation
Start Win, Enter DOS, Exit DOS,
Exit Win
Suspend and Resume
Installation
Start Win, Enter DOS, Exit DOS,
Exit Win
Suspend and Resume
Installation
Start Win, Enter DOS, Exit DOS,
Exit Win
Suspend and Resume
Installation
Start Win, Enter DOS, Exit DOS,
Exit Win
Suspend and Resume
Pass
Remarks
Pass
Pass
Pass
Pass
Pass
3
Test Report
MS-WindowsXP
HomeEdition
2002
SP1
MS-WindowsXP
Professional
(English,Chinese Version)
Red Hat Linux
(English,Chinese Version)
2002
SP1
Installation, Driver,
Start Win,Shutdown,Suspend
and Resume
Installation, Driver,
Start Win,Shutdown,Suspend
and Resume
Installation
Boot, Reboot, X-Windows
V7.2
Pass
Pass
pass
III. Add-on Card
Vender
Function
Model
Bus
Result
Adaptec
SCSI
ACS-39160
PCI
PASS
ACS-29160
PCI
PASS
AHA-1542C
ISA
PASS
DE-530
PCI
PASS
DE-220PCT
ISA
PASS
3C-905C
PCI
PASS
3C-509B
ISA
PASS
Intel 82550
PCI
PASS
Intel 82559
PCI
PASS
Intel 82540
PCI
PASS
GVC-F1
PCI
D-Link
LAN
3COM
Intel
GVC
4
Modem
Remark
PASS
P1123-671
Test Report
CHAPTER 3 Reliability
I. Operating Temperature and Humidity Test
System Configuration:
Item
Description
Item
Description
P1123-671
Samsung 512MB(Unigen)
CPU Type
HDD
Toshiba MK2018GAP
20GB,2.5”
K/B
Sampo 101 key
Monitor
ADI 15”
Mouse
Logitech M-S34 PS/2
Model
DRAM
PIII-1.4GMHz
System BIOS B10.1F.0
Test Equipment
Temperature & Humidity Chamber
C SUN Indostrial Co., LTD
Model: HCP-3P
S/N: F42627
Date of Calibration: 05/14/2002
Test Ambience
Temperature: 19℃ ~ 27℃
Humidity: 54 ~ 64% (RH)
Test Condition
Run HCT9.5 System Stress under Win2000
Humidity
95%RH
1Hr
5Hr
1Hr
50%RH
Time
5Hr
//
10%RH
No Humidity
Temperature
40℃
1 Hr
11Hr
1Hr
25℃
11Hr
Time
0℃
P1123-671
5
Test Report
Number of Cycle
2 cycles (Total Time:48 hours)
Test Criteria
During and after the test:
1. Electrical Function:
(1) The system must function normal
2.Appearance and mechanical function:
(1)No mold speckle.
(2)No unclear letter,broken line.
(3)No letters or symbols on cabinet are missing
(4)No stiffness or squeak for buttons when pressed
(5)No warp or rust for metal parts
Test Result
■ PASS Electrical function and appearance&mechanical function were normal.:.
□ FAIL : __________________________________________________________
Figure 3-1: P1123-671 Operating Temp/Humidity test
6
P1123-671
Test Report
II. Low/High Temperature & Room Temperature Cold Start Test
System Configuration:
Item
Description
Item
Description
P1123-671
Samsung 512MB(Unigen)
CPU Type
HDD
Toshiba MK2018GAP
20GB,2.5”
K/B
Sampo 101 key
Monitor
ADI 15”
Mouse
Logitech M-S34 PS/2
Model
DRAM
PIII-1.4GMHz
System BIOS B10.1F.0
Test Equipment
Temperature & Humidity Chamber
C SUN Indostrial Co., LTD
Model: HCP-3P
S/N: F42627
Date of Calibration: 05/14/2002
Test Ambience
Temperature: 19℃ ~ 27℃
Humidity: 54 ~ 64% (RH)
Test Condition
(1) Low Temperature
Test Procedure:
Section Temp.
1
2
3
4
5
6
7
8
9
10
11
P1123-671
0℃
0℃
0℃
0℃
0℃
0℃
0℃
0℃
0℃
0℃
0℃
Time
Operation
Remarks
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
(Power off)
1 Hour
10Min
10Min
10Min
1 Hour
10Min
7
Test Report
12
13
14
15
16
0℃
0℃
0℃
0℃
0℃
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
10Min
10Min
Humidity
No Humidity
95%RH
//
50%RH
5 times
5 times
5 times
5 times
10%RH
//
5 times
5 times
5 times
5 times
Temperature
Power On/Off
Times
60℃
50℃
25℃
0℃
-5℃
1 Hr
1Hr
10 min 10 min 10 min
10 min 10 min 10 min
Power Off
Time
Figure 3-2: Test Profile for Low Temperature Cold Start test
(2) High Temperature
Test Procedure:
Section Temp.
1
40℃
2
40℃
3
40℃
4
40℃
5
40℃
6
40℃
7
40℃
8
40℃
9
40℃
10
40℃
11
40℃
12
40℃
13
40℃
14
40℃
8
Time
1 Hour
Operation
Remarks
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
Power on/off 5 Times
Cold Start
10Min
10Min
10Min
1 Hour
10Min
10Min
P1123-671
Test Report
15
16
40℃
40℃
10Min
Power on/off 5 Times
Cold Start
Humidity
95%RH
50%RH
5 times
5 times
5 times
5 times
5 times
5 times Power On/Off
Times
5 times
5 times
10%RH
Temperature
60℃
40℃
1 Hr
1Hr
10 min 10 min 10 min
10 min 10 min 10 min
Power Off
Time
25℃
Figure 3-3: Test Profile for High Temperature Cold Start test
(3) Room Temperature
(3-1) System On (cold start,Booting Ok and Entering OS successfully)
(3-2) System Off Time:10 Second
(3-3) System ON/OFF Cycle :100 Times
Test Criteria
The system must function normally from POST to entering Windows 2000 professional at the
cold boot for temperature factor
Test Result
(1) Cold start test at Low temperature :PASS
(2) Cold start test at high temperature :PASS
(3) Cold start test at Room temperature:PASS
P1123-671
9
Test Report
III. Temperature/Thermal profile Test
System Configuration
Item
Description
Item
Description
P1123-671
Samsung 512MB(Unigen)
CPU Type
HDD
Toshiba MK2018GAP
20GB,2.5”
K/B
Sampo 101 key
Monitor
ADI 15”
Mouse
Logitech M-S34 PS/2
Model
DRAM
PIII-1.4GMHz
System BIOS B10.1F.0
Test Equipment:
Temperature & Humidity Chamber
C SUN Indostrial Co., LTD
Model: HCP-3P
S/N: F42627
Date of Calibration: 05/14/2002
Temperature Record
YOKOGAWA
Model:UR1800
Test Condition:
Chamber Temp: 40℃
Test program:System stress for Win2000(HCT 9.5)
Time:24 hrs. Dynamic Burn-In
Test Criteria
The measured temperature for each point must meet the components spec.
Test Result:
Item
10
Temperature(max)
Environment Temp
40.60C
Above CPU Board
52.60C
Tcase for Touch screen Controller
51.80C
Tcase for Power Heatsink
58.20C
Tcase for RTL 8139C(U11)
54.80C
P1123-671
Test Report
Tcase for VGA C&T69000 (U1)
66.80C
Tcase for CLK Generator (U4)
63.30C
Tcase for VIA VT82C694T (U2)
60.30C
Tcase for VIA VT82C686B (U5)
58.50C
Tcase for Winbond W83877TF (U7)
54.70C
Power around
51.50C
Riser around
47.30C
Tcase for HDD
54.40C
Tcase for CPU PIII 1.4GHz
63.60C
■ PASS: The P1123-671 meets the profile test
Figure 3-4 : Temperature / Thermal profile test
P1123-671
11
Test Report
CHAPTER 4 Vibration Testing
I. EUT Test
Model: P1123-671
CPU: Intel PIII-1.4GHz
DIMM: Samsung 512MB x 1
HDD: Toshiba MK2018GAP 20 GB(2.5”)
II. Test Equipment
Vibration Simulator System
KING DESIGN Co., LTD
Model: KD-9363EM-300F2K-30N80
S/N: 9Y103059387
Date of Calibration: 06/04/2002
III. Test Condition
Frequency: 5Hz-------17Hz----------500Hz
Amplitude/Acceleration: 0.1” p-p / 1.5G
Direction: X, Y, Z Axis
Time: 1hour each Axis
Acceleration
1.5G
1.5G
0.1”p-p
5 Hz
12
17Hz
500Hz
Frequency Herztz
P1123-671
Test Report
Top
Z axis
Y axis
X axis
Front Panel
IV. Test Criteria
After the test:
2. Electrical Function:Test all function and boot to OS(win2000 professional)
3. Appearance and mechanical function:
(1) The EUT should not suffer permanent deformation or fracture.
(2) No fixed part or assembly shall be loosening
(3) No moving or movable part of an assembly should become free or sluggish in the testing
process
(4) No movable part should shift in setting ,position or adjustment.
V. Test Result
■PASS: Electrical function and appearance&mechanical function were normal.
□FAIL :
P1123-671
13
Test Report
Figure 4-1: P1123-671 Package Vibration test for Z axis
Figure 4-2: P1123-671 Package Vibration test for Y axis
14
P1123-671
Test Report
Figure 4-3: P1123-671 Package Vibraiton test for X axis
P1123-671
15
Test Report
CHAPTER 5 Drop Testing
I. EUT Test
Model: P1123-671 /W SBC83671VEA
CPU: Intel PIII-1.4GHz
DIMM Samsung 512MB (Unigen)
HDD: Toshiba MK2018GAP 20GB 2.5”
II. Test Equipment
Drop Simulator System
KING DESIGN Co., LTD
Model: KD128
S/N: 9V103059487
III. Packing Condition
Weight: 6.958KG
Dimension: 42cm x 43 cm x 21 cm
IV. Dropping Condition
Height: 91cm
Dropping direction: 10 directions (1 corner, 3 edges, 6 faces)
16
P1123-671
Test Report
1: Top
6: Far end
2: Right side
4: Left side
5: Near end
3: Buttom
Packaging drop sequence of the total 10 times dropping test:
1. The 3-4- 6Corner
6. The Right side face
2. The 3-4 Edge
7. The Bottom face
3. The 4-6 Edge
8. The Top face
4. The 3-6 Edge
9. The Near end face
5. The Left side face
10. The Far end face
V. Test Criteria
After the test:
1. Electrical Function:Test all function and boot to OS(win2000 professional)
2.Appearance and mechanical function:
(1) No scratch.
(2) No dent
(3) No crack
(4) No mold speckle.
(5) No warp for metal parts
(6) No slack(e.g. screw loose
(7) No fixed part or assembly shall be loosening
(8) No moving or movable part of an assembly should become free or sluggish in the testing process
(9) No movable part should shift in setting ,position or adjustment.
(10) No severe cracks to cushion
(11) No severe damage to carton box
VI. Test Result
■ PASS: Electrical function and appearance&mechanical function were normal.
□FAIL :
P1123-671
17
Test Report
Figure 5-1: P1123-671 Package Dropping Test for the 3-4-6 Corner
Figure 5-2: P1123-671 Package Dropping Test for the left face
18
P1123-671
Test Report
Figure 5-3: P1123-3671 Package Droping Test for the 4-6 edge
P1123-671
19
Test Report
APPENDIX 1 : Approved Problem Summary
Revised Date:05/09/2003
Model Name: Panel 1123-671
Hardware Revision: A0
BIOS Revision:SBC83671VEA BIOS:B10.1F.0
Test Engineer: Lewis,,Jason
Problem Problem Problem Operating Problem Description
ID
level
Status
System
P1123-671
Problem Solution
1