Buckeye Fire Equipment Kings Mountain, NC
Transcription
Buckeye Fire Equipment Kings Mountain, NC
10/14/2011 Buckeye Fire Equipment Kings Mountain, NC BUCKEYE FIRE EQUIPMENT COMPANY AMERICAN MADE SINCE 1968 • • For over four decades Buckeye Fire Equipment has been an international leader in the development and manufacture of reliable fire protection products. A privately owned and operated company with its headquarters near Charlotte, NC, Buckeye Fire Equipment has earned an excellent reputation for quality, reliability and value within the commercial and industrial fire protection industry. We offer a complete line of handheld and wheeled fire extinguishers, extinguishing agents, fire suppressing foam concentrates & hardware and pre-engineered kitchen suppression systems. To ensure our distributors and customers get the highest quality fire protection equipment, all of our products undergo rigorous testing, both in-house and by third party testing organizations such as Underwriters Laboratories, Factory Mutual, ASME and the U.S. Government. We are committed to helpful and responsive customer service and knowledgeable and dependable technical support. This commitment has earned Buckeye Fire Equipment the coveted ISO 9001-2000 Quality Certification. Contact us for more information about the wide selection of Buckeye Fire Equipment Company products and services. We have trained personnel who are ready to assist you with your fire protection needs. Buckeye Fire Equipment. PO Box 428, 110 Kings Road, Kings Mountain, North Carolina 28086 Tel. 704 739 7415. Fax. 704 739 7418. Email: [email protected] 1 10/14/2011 NFPA 96 Overview Presented By: Michael J. Laderoute Director of PE Sales Buckeye Fire Equipment Michael J. Laderoute Bio: • 43 years experience in Fire Protection • First 20 years as a Fire Equipment Distributor • Remaining 23 years representing various manufacturers • Past Technical Committee Member: • NFPA 1, 10, 17, 17A, 96, 101, 505 & 5000 • Past Member UL STP Committee • 605, 300, 407 • Member ICC/NAFED …….. EDC ( PES ) • Served ( 9 years ) as FEMA’s Code Consultant • Inventor: Fire extinguisher discharge nozzle • Recipient NAFED’s Lifetime Achievement Award (2006) • Director of PE Sales, Buckeye Fire Equipment 2 10/14/2011 Seminar Content • NFPA 96, Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations • Based on 2011 Edition of NFPA 96 • Although helpful, you do not need to have this document with you. Special Note: • Although I will be reviewing many of the requirements directed at the hood and duct design, it is not my intent to make you an expert in mechanical design. • Instead, it is my hope to open your eyes to the possible hazards and problems that may exists down stream, looking beyond the tank and nozzles that can affect the performance of the Exhaust System and the Fire Suppression System. 3 10/14/2011 Seminar Content •Standards may not be highlighted in its entirety. •Sections may not be sequential. •When possible photos will be shown for clarity and for better understanding. Keep in Mind • There are many similarities among NFPA 96, 17A & NFPA 10. • NFPA standards are all setup the same • Contents are listed by Chapter at the front of each standard • The first three chapters are always Administration, Referenced Publications and Definitions 4 10/14/2011 Keep in Mind • • • • The chapters contain mandatory language and the annex contains explanatory and additional information for guidance. The index is located at the end of the standard An * by a section number indicates there is explanatory information in Annex A bar in the column indicates new text from the previous edition Presentation Guidelines • I will not be explaining why there are specific NFPA Requirements. • I may not cover every section or requirement of the standard. • For better understanding I may not cover each requirement in sequential order. 5 10/14/2011 Presentation Guidelines • I will attempt however, to show actual • examples of requirement when and where appropriate. (Approved & Unapproved) It is helpful to you if you are familiar with the setup of each standard and know how to find information in the specific standard that you are seeking. NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations 2011 Edition 6 10/14/2011 History Facts • First adopted in 1946 • There have been some 15 revisions since 1955 Brief History of NFPA 96 • In 1994 the standard underwent a name change from the “Standard for the Installation of Equipment for the Removal of Smoke & Grease Laden Vapors from Cooking Equipment” to the “Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations”. The title reflected changes in the standard such as re-circulating systems and solid fuel cooking operation. 7 10/14/2011 Brief History of NFPA 96 • The 2004 edition added a chapter that addressed the requirements for downdraft appliance ventilation, as well as, clarifications of the requirements for cleaning and maintaining exhaust systems and diagrams detailing new arrangements for hoods with integrated supply air. • This edition also added the definition of Certified and also required Certified Person(s) or Company acceptable to the AHJ.. NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations 2011 Edition 8 10/14/2011 Preamble Commercial cooking operations are complicated and involve multiple levels and degree of hazard. Properly designed, they encompass an exhaust hood(s), an exhaust duct(s), ventilation fan(s) and grease extractor(s) device(s). Additionally, located beneath this ventilation system are cooking appliances in many variations and design. This unique hazard presents a risk of fire if not properly designed, installed, inspected and maintained. Preamble Each component is critical link to the overall success of fire suppression or extinguishment should a fire occur. NFPA 96 attempts to outline requirements that are critical to a complete system assuring the greatest degree of operation and success. Ventilation systems, ducts, extractors, cooking equipment installed outside these requirements are not covered in this standard and are not consider suitable in meeting the intent of this document. 9 10/14/2011 Preamble It is imperative that any person(s) involved with inspection, maintenance and installation be familiar with the problems that can result when the requirements of NFPA 96, the product Listing and the Manufacturer installation and maintenance instruction are not adhered. Preamble Pre-engineered extinguishing systems are tested and listed for protection of cooking hazards designed and installed in accordance with NFPA 96. If an installed system is outside of the scope of NFPA 96, its expected performance, should it be called upon is questionable. There is a greater possibility that the system may not extinguish a fire if the hazard is outside of the system’s design scope. 10 10/14/2011 Preamble The following presentation is intended to provide some insight as to what one may encounter in the real world and how it might affect the overall hazard. Meeting or complying with a standard or code is only the minimum threshold. Ask Yourself….. “How many restaurants Am I prepared to own?” 11 10/14/2011 Standard applies to commercial kitchens Who’s – Who’s •3.2.1* Approved. Acceptable to the Authority Having Jurisdiction •3.2.2* Authority Having Jurisdiction (AHJ). An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, and installation, or procedure. 12 10/14/2011 3.2.4 Listed 3.2.4* Listed. Equipment, materials, or services included in a list published by an organization that is acceptable to the AHJ and concerned with evaluation of products or services, that maintains periodic inspection of production of listed equipment or materials or periodic evaluation of services, and whose listing states that either the equipment, material, or service meets appropriate designated standards or has been tested and found suitable for a specified purpose. NRTL Shall Vs Should • 3.2.5 Shall. Indicates a mandatory requirement. (always found within the enforceable part of the standard) • 3.2.6 Should. Indicates a recommendation or that which is advised but not required. (usually found in the Annex of the standard) 13 10/14/2011 3.3.34* Hood 3.3.33 A device provided for a cooking appliance(s) to direct and capture grease-laden vapors and exhaust gases. 14 10/14/2011 Direct and Capture Gases •Trail of smoke must be able to be captured by the hood. •Air flow must be able to pull all affluent from the cooking line. 15 10/14/2011 F Direct and Capture Gases Correct •Trail of smoke must be able to be captured by the hood. •Air flow must be able to pull all affluent from the cooking line. Incorrect 16 10/14/2011 3.3.35 Interconnected 3.3.35 Mutually assembled to another component in such a manner that the operation of one directly affects the other or that the contents of one specific duct system are allowed to encounter or contact the products being moved by another duct system. Back to Back Exhibition Cooking Single Hazard Area 3.3.45 Where two or more hazards can be simultaneously involved in fire by reason of their proximity, as determined by the AHJ. exhausted separately 17 10/14/2011 Baffle Filters 3.3.25 Filters 3.3.25.1* Grease Filter. A removable component of the grease removal system designed to capture grease and direct it to a safe collection point. Grease collects on baffle plates 18 10/14/2011 19 10/14/2011 Mesh-Type Filter 3.3.25.2* Mesh-Type Filter. A filter construction consisting of a net made from intersecting strands with a space between each strand. Spark Arrester 3.3.49 Spark Arrester. A device or method that minimizes the passage of airborne sparks and embers into a plenum, duct, and flue. Frame and Arrester Screen Mandatory when using solid fuel for cooking 20 10/14/2011 Approved filters will carry a stamped or metal label 21 10/14/2011 Grease Filters and Drip Trays • 6.2.4.1 Filters shall be equipped with a drip tray beneath their lower edges. • 6.2.4.2 The tray shall be kept to the minimum size needed to collect grease • 6.2.4.3 Grease drip trays shall be pitched to drain into an enclosed metal container having a capacity not exceeding one gallon. • 6.2.5 Grease filters that require a specific orientation to drain grease shall be clearly so designated …cannot be installed in the wrong direction 22 10/14/2011 Chapter 4 General Requirements 4.1.1 Cooking equipment used in processes producing smoke or grease-laden vapors shall be equipped with an exhaust system that complies with all the equipment and performance requirements of this standard. 23 10/14/2011 Chain Broiler or Pizza Oven 3.3.46 Solid Cooking Fuel 3.3.34 Any solid, organic, consumable fuel such as briquettes, mesquite, hardwood, or charcoal. Charcoal or Briquettes Mesquite or Hardwood 24 10/14/2011 25 10/14/2011 Improper method of collecting ashes 26 10/14/2011 This type of rotisserie has its fuel supplied from charcoal which is also classified as a solid fuel Solid Fuel Cooking Operations • 14.3.3 Exhaust systems serving solid fuel cooking equipment, including gas or electrically operated equipment, shall be separate from all other exhaust systems. • 14.3.4 Cooking processes, including but not limited to those that use any solid fuel for cooking enhancement or smoke flavoring, shall comply with 14.3.3 and Section 14.8. 27 10/14/2011 Solid Fuel Cooking Operations • 14.7.1 Solid fuel cooking appliances that produce grease laden vapors shall be protected by listed fire-extinguishing equipment. • 14.7.5 Listed fire extinguishing equipment for solid fuel burning cooking appliances, where required, shall comply with Chapter 10 and shall use water based agents. Solid Fuel Cooking Operations • 14.7.8 All solid fuel appliances (whether or not under a hood) with fire boxes of 5 cu ft (0.14 m 3 ) volume or less shall at least have a 2-A-rated water spraytype or a 6 L wet chemical fire extinguisher listed for Class K fires in accordance with NFPA 10 with a maximum travel distance of 20 ft. to the appliance.. OR Water 2A Rated Wet Chemical K Rated 28 10/14/2011 Acceptable Design Hood Construction 5.1.1 The hood or that portion of a primary collection means designed for collecting cooking vapors and residues shall be constructed of and be supported by steel not less than 1.09 mm (0.43 in.) (No. 18 MSG) in thickness, stainless steel not less than 0.94 mm (0.37 in.) (No. 20 MSG) in thickness, or other approved material of equivalent strength and fire and corrosion resistance. 5.3 Exhaust Hood Assembly with Integrated Supply Air Plenums Unacceptable Design exhaust air in •5.3.4.1 A fire actuated damper shall be installed in the supply air plenum at each point where a supply air duct inlet or a supply air outlet penetrates the continuously welded shell of the assembly. •5.3.4.2 The fire damper shall be listed for such use or be a part of a listed exhaust hood with or without exhaust damper. Supply air shall be shutdown upon system activation 29 10/14/2011 Fusible Links on Fire Damper Assemblies •11.3.1 Actuation components for fire dampers shall be inspected for proper operation in accordance with the manufacturer’s listed procedures. •11.3.2.1 Fusible links on fire damper assemblies shall be replaced at least semiannually or more frequently as necessary. •11.3.2.2 Replacement shall be made by a certified person(s) acceptable to the AHJ. 30 10/14/2011 31 10/14/2011 PLYWOOD!!! 32 10/14/2011 IMC 507.12 requires a 6” overhang 5.2 Hood 5.2 Hood. Hoods shall be sized and configured to provide for the capture and removal of grease-laden vapors. 33 10/14/2011 Seams & Joints 5.1.2 All seams, joints, and penetrations of the hood enclosure that direct and capture grease-laden vapors and exhaust gases shall have a liquidtight continuous external weld to the hood’s lower outermost perimeter. 5.1.3 Seams, joints, and penetrations of the hood shall be permitted to be internally welded, provided that the weld is formed smooth or ground smooth, so as to not trap grease, and is cleanable. Must be liquidtight •Seams not welded •Not liquidtight 34 10/14/2011 35 10/14/2011 36 10/14/2011 Penetrations Pipe and Conduit Screw Penetration 5.1.5 Penetrations shall be permitted to be sealed by devices that are listed for such use and whose presence does not detract from the hood’s or duct’s structural integrity. Pipe and Conduit Penetration Access Panel Penetration 37 10/14/2011 38 10/14/2011 4.2* Clearance 4.2.1 Where enclosures are not required, hoods, grease removal devices, exhaust fans, and ducts shall have a clearance of at least 457 mm (18 in.) to combustible material, 76 mm (3 in.) to limited combustible material, and 0 mm (0 in.) to noncombustible material. In each case above min. clearance was not adhered to 39 10/14/2011 Clearance Exhaust 4.2.4.3 Protection shall be provided on the wall from the bottom of the hood to the floor, or to the top of the noncombustible material extending to the floor. Red indicates noncombustible area 40 10/14/2011 Duct Systems •7.1.1 “Shall” not pass through fire walls. •7.1.2 “Shall” lead as directly as possible to the outside of the building. •7.1.3 “Shall” not be interconnected with any other building ventilation or exhaust system. Must Provide Clearance of at least (18 in.) to combustible 41 10/14/2011 No clearances 42 10/14/2011 Charred wood due to improper clearances Example: Improper Duct Installation •Duct Tape •Leaking Seams 43 10/14/2011 44 10/14/2011 Clearance •Explosive Hazard •Exposed combustible •Clearance and termination point code violation 45 10/14/2011 46 10/14/2011 Would be acceptable if Listed 5.4* Listed Hood Assemblies 5.4.1 Listed hood assemblies shall be installed in accordance with the terms of their listing and the manufacturer’s instructions. 5.4.2 Listed hood assemblies shall be tested in accordance with UL 710 or equivalent. 5.5 Listed Ultraviolet Hoods. Listed ultraviolet hoods shall be installed and maintained in accordance with the terms of their listing and the manufacturer’s instructions. 5.6 Listed Ventilated Ceiling Technology. Listed ventilated ceiling technology shall be installed and maintained in accordance with the terms of its listing and the manufacturer’s instructions. 47 10/14/2011 Openings / Clean-outs •7.3.1 openings shall be provided at the sides or at the top of the duct, whichever is more accessible, and at changes of direction. •7.3.2 Openings shall be protected by approved access. Clean outs are required every 12 feet and in every change of directions 48 10/14/2011 Openings/Clean-Outs 7.1.6 A sign stating the following shall be placed on all access panels ACCESS PANEL DO NOT OBSTRUCT 49 10/14/2011 4.1.8 4.1.8 All interior surfaces of the exhaust system shall be accessible for cleaning and inspection purposes. 7.3.1 sides, top, change in direction Accessible for cleaning and inspection •What you don’t see •Home made access panel 7.4.1.1 requires 20” X 20” 50 10/14/2011 51 10/14/2011 7.3.1 sides, top, change in direction Accessible for cleaning and inspection •Excessive grease •Note “Duct Tape” •No approved duct 52 10/14/2011 Down Draft Appliance Ventilation Systems 15.1 General Requirements. Down draft appliance ventilation systems containing or for use with appliances used in processes producing smoke or grease laden vapors shall be equipped with components complying with the following chapters: 4, 5, 6, 7, 8, 9,10,11,12 15.1.2 The down draft appliance ventilation system shall be capable of capturing and containing all of the effluent discharging from the appliance(s) it is serving. 53 10/14/2011 Down Draft Ventilation Systems 15.1.1 Down draft appliance ventilation systems containing or for use with appliances used in processes producing smoke or grease-laden vapors shall be equipped with components complying with the following: •(8) Fire-extinguishing equipment complying with the requirements of Chapter 10 and as specified in Section 15.2 Annex Note A15.1 Interlock (1) Cooking surface protection shall be provided. (2) At least one fusible link or heat detector shall be installed within each exhaust duct opening in accordance with the manufacturer's listing. (3) A fusible link or heat detector shall be provided above each protected cooking appliance and in accordance with the extinguishing system manufacturer’s listing. (4) A manual activation device shall be provided as part of each appliance at a height acceptable to the authority having jurisdiction. 54 10/14/2011 Dips or Traps • 7.1.4 All ducts shall be installed without forming dips or traps that might collect residues. • 7.1.4.2 Exhaust dusts used in downdraft appliance ventilation systems shall be allowed to include an upturn in the duct provided the trapped area contains a low point drain to an approved grease reservoir not exceeding 1 gallon in capacity and the entire length of the duct is easily accessible for cleaning. Problem Area Need Drain Installation and Maintenance Issues Actual Facilities 55 10/14/2011 Installation and Maintenance Installation and Maintenance Problems Grease buildup is running out of the fan and down the roof, down a wood fence and onto the gas meter 56 10/14/2011 Poorly designed Make up air •Improper pitch measurements •Poorly pieced together ductwork with holes and gaps Improper Termination •Incorrect placement •Curb sits on wooden base •No cleaning provisions •Clearance issues to combustibles •Utility wires •Window 57 10/14/2011 Improper Termination •Lacks 10’ clearance to windows •Not 40” above roofline •Clearance to combustible issue Up-blast Fans • 8.1.1.1 Approved up-blast fans with motors surrounded by the airstream shall be hinged, supplied with flexible weatherproof electrical cable and service hold-open retainers, and listed for this use. • 8.1.2.1 In-Line Exhaust Fans – motors outside airstream – belts, pulleys protected with greasetight housing. • 8.1.4 Exhaust fan housings shall be constructed of carbon steel not less than 16 gauge or stainless 18 gauge or per the terms of the listing. 58 10/14/2011 Code Violation! No wires allowed in duct work Chain 59 10/14/2011 Proper Rooftop Installation •Hinged Up-Blast Fan •Proper Housing •40” Above Roofline •UL listed for Kitchen Exhaust •Wired per NEC Chapter 10 -Fire Extinguishing Equipment • 10.1.1 Fire-extinguishing equipment for the protection of grease removal devices, hood exhaust plenums, and exhaust duct systems shall be provided. 60 10/14/2011 UL 300 & Listings •10.2.3* Automatic fire-extinguishing systems shall comply with standard UL300 … or other equivalent standards and shall be installed in accordance the requirements of the listing. •10.2.3.1 In existing systems, when changes in the cooking media, positioning, or replacement of cooking equipment occur, the fire extinguishing system shall be made to comply with 10.2.3 (UL 300). UL300 Fire Test 60” Griddle. Nozzle installed on one end at 10’ off the surface. 61 10/14/2011 10.1.2 * Cooking equipment that produces grease laden vapors and that might be a source of ignition of grease in the hood, grease removal device, or duct shall be protected by fire-extinguishing equipment. More Appliances Split Vat Fryer Single Vat Fryer 62 10/14/2011 Unique Appliances Chapter 10 -Fire Extinguishing Equipment • 10.2.1 Fire extinguishing equipment shall include BOTH automatic fire extinguishing systems as primary protection and portable fire extinguishers as secondary backup. Positive Result Both 63 10/14/2011 NFPA 10 Portable Extinguishers 2010 Edition • 5.5. Class K Cooking Media Fires. Fire extinguishers provided for the protection of cooking appliances that use combustible cooking media (vegetable or animal oils and fats) shall be listed and labeled for Class K fires. K •10.2.2 A placard shall be conspicuously placed near each extinguisher that states that “the fire protection system shall be activated prior” to using the fire extinguisher. Placard ATTENTION 64 10/14/2011 Class “K” Extinguisher Example Must have placard near extinguisher 10.2.7 Modifications to Existing Hood Systems •10.2.7.1 Any abandoned pipe or conduit from a previous installation shall be removed from within the hood, plenum, and exhaust duct. •10.2.7.2 Penetrations and holes resulting from the removal of conduit or piping shall be sealed with listed or equivalent liquidtight sealing devices. 65 10/14/2011 Appliances on Wheels •12.1.2.2* Cooking appliances requiring protection shall not be moved, modified, or rearranged without prior re-evaluation of the fire extinguishing system by the system installer or servicing agent, unless otherwise allowed by the design of the fire extinguishing system. •12.1.2.3 Fire extinguishing system shall not require reevaluation where cooking appliances are moved for the purposes of maintenance & cleaning, provided the appliances are returned to the original design location. •12.1.2.3.1 An approved method shall be provided that will ensure that the appliance is returned to the original design location. 66 10/14/2011 • 12.1.2.4 All deep fat fryers shall be installed with at least a 16 in. space between the fryer and surface flames from adjacent cooking equipment. • 12.1.2.5 Where a steel or tempered glass baffle plate is installed at a minimum 8 in. (203 mm) in height between the fryer and surface flames of the adjacent appliance the requirement does not apply • 12.1.2.5.1 If the fryer and the surface flames are at different planes the minimum height shall be measured from the higher of the two. 67 10/14/2011 10.4 Fuel Shut Off • 10.4.1 Upon activation of any fire extinguishing system for a cooking operation, all sources of fuel and electric power that produce heat to all equipment requiring protection by that system shall automatically shut off. • 10.4.3 Any gas appliance not requiring protection, but located under the same ventilating equipment, shall also automatically shut off upon activation of any extinguishing system. • 10.4.4 Shutoff devices shall require manual reset. 68 10/14/2011 Manual Activation • 10.5.1 A readily accessible means for manual activation shall be located between 42 in. and 48 in. above the floor, located in a path of exit or egress, and clearly identify the hazard protected. • 10.5.1.1 A manual actuation device shall be located a minimum of 10 ft. when possible and a maximum of 20 ft. from the protected kitchen appliance(s) within the path of egress. • 10.5.2 The automatic and manual means of system activation external to the control head or releasing device, shall be separate and independent of each other so that failure of one will not impair the operation of the other except as permitted by 10.5.3. 10.9 Review & Certification • 10.9.1 Where required, complete drawing of the system installation, including the hood(s), exhaust duct(s), and appliances, along with the interface of the fire extinguishing system detectors, piping, nozzles, fuel shutoff devices, agent storage container(s), and manual actuation device(s), shall be submitted to the authority having jurisdiction. 69 10/14/2011 When Drawings are required they shall include sufficient details to satisfy the AHJ. Drawings can range from a simple 8 ½ x 11 hand sketch to detailed AutoCAD. Sample only 10.9.2* Installation Requirements • 10.9.2.1 Installation of systems shall be performed only by persons properly trained and qualified to install the specific system being provided. • 10.9.2.2 The installer shall provide certification to the authority having jurisdiction that the installation is in complete agreement with the terms of the listing and the manufacturer's instructions and/or approved design. • Annex - Although training and qualification may be available elsewhere, the manufacturer of the equipment being installed should be considered an appropriate source of training and qualification. 70 10/14/2011 MFG. Certification Required Industry Certification Required by NFPA 17A & 96 71 10/14/2011 Certification to AHJ Proper Systems Installation •Fuel shut off operable gas/electric •Fully functioning •Accessories tested •Pull Station •Detection •Building Alarm •Cylinder full •CO2 cart replaced •Pulleys free and operational •As per the System Manual •Special Considerations •Etc…………………. Sample Procedures for the use and Maintenance of Equipment • 11.2.4* Fusible links of the metal alloy type (including fusible links on fire damper assemblies and automatic sprinkler heads) shall be replaced at least semiannually, or more frequently if necessary where required by the manufacturer. • 11.2.5 Year of mfg. and date of installation shall be marked on system inspection tag. • 11.2.5.1 The tag shall be signed or initialed by the installer. 72 10/14/2011 3.3.29 Fusible Link 3.3.29 A form of fixed temperature heat detecting device sometimes employed to restrain the operation of an electrical of mechanical control until its designed temperature is reached. 73 10/14/2011 74 10/14/2011 Inspection Issues a few examples Improper installation creates a grease trap 75 10/14/2011 76 10/14/2011 77 10/14/2011 78 10/14/2011 79 10/14/2011 80 10/14/2011 Important Note: The previous slides serve as a reminder of the importance of doing Hazard Analysis, PROPER Installation, as well as, DETAILED system Inspections. They serve as examples of actual installations where “so called” qualified persons designed, installed, and were maintaining these systems. Please recognize that these deficiencies represent a small fraction of actual system installations. Trained and Certified persons are essential in order to assure AHJ’s and End-Users that proper Hazard Analysis, correct Installations and complete Inspections are being done as per the appropriate codes and standards, as well as the Manufacturers’ Installation & Maintenance Manuals. 81 10/14/2011 Use and Maintenance of Equipment •11.4* The entire exhaust system shall be inspected for grease buildup by properly trained, qualified, and certified company or person(s) acceptable to the AHJ in accordance with Table 11.4 Please stop by our Table #25 To view our products. 82 10/14/2011 Q&A 83
Similar documents
NFPA 96 Overview - Johnson Diversified Products
7.8.2.1 Rooftop terminations shall be arranged with or provided with the following: • (1) A minimum of 3.05 m (10 ft) of horizontal clearance from the outlet to adjacent buildings, property lines a...
More information