6078 La Plaza Mall – Sunglass Hut – McAllen_TX
Transcription
6078 La Plaza Mall – Sunglass Hut – McAllen_TX
1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 REMODEL 2.0 PREMIUM K CONSULTANT PROJECT # 150343 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect J SEAL FOR LA PLAZA MALL H STORE # 6078 2220 S. 10TH STREET SPACE #Q14-C McALLEN, TX 78503 G IF REQ'D, STOCKROOM SHELVING TO BE UNDER SEPARATE PERMIT, SUBMITTED BY SHELVING MANUFACTURER. SIGNAGE AND SPRINKLER PLAN TO BE SUBMITTED UNDER SEPARATE COVER DRAWING INDEX DRAWING DESCRIPTION SUNGLASS HUT SPACE:#Q14-C LEVEL 1 OF 1 E RESTROOMS USER: JGRAY PLOTTED: 7/16/2015 - 4:03 PM C:\TempScan\AcPublish_1732\G-001_06078.dwg LAYOUT: G-001 D G-001 COVER SHEET G-002 RESPONSIBILITY & DOOR SCHEDULE A-101 DEMOLITION / LEASE PLAN A-102 FLOOR PLAN A-103 FINISH / FIXTURE PLAN A-104 REFLECTED CEILING PLAN A-201 ELEVATIONS A-301 NOT USED A-401 STOREFRONT ELEVATION A-501 NOT USED A-502 GENERAL DETAILS A-503 FRAMING DETAILS A-504 FRAMING DETAILS A-505 NOT USED A-701 ARCHITECTURAL SPECIFICATIONS A-702 ARCHITECTURAL SPECIFICATIONS THIS PROJECT IS A TENANT BUILD OUT OF A EXISTING MERCANTILE SPACE IN AN EXISTING INTERIOR CENTER. NORTH PROJECT CONTACTS C Project Manager B M-101 MECHANICAL PLAN & LEGEND M-501 MECHANICAL DETAILS & ABBREVIATIONS M-MERCANTILE IIB A TENANT SEPARATION WALLS: SALES/NON-SALES WALLS: CEILING: COLUMNS: 1 HR 0 HR 0 HR 0 HR SALES AREA: NON-SALES AREA: TOTAL: 436/30 = 15 21/300 = 1 16 EXITS REQUIRED: EXITS PROVIDED: 1 1 SHREMSHOCK ARCHITECTS 7400 W. CAMPUS RD. SUITE 150 NEW ALBANY, OH 43054 CONTACT: JASON RICHARDSON PHONE: 614-545-4550 E-MAIL: [email protected] SYMBOLS LEGEND A1 SECTION ID SHEET NUMBER A-301 A1 A-401 - - - NOT REQUIRED NOT REQUIRED NOT REQUIRED SUNGLASS HUT LA PLAZA MALL M-701 FIRE PROTECTION SPECIFICATIONS Architect LUXOTTICA 4000 LUXOTTICA PLACE MASON, OH 45040 CONTACT: SHEILA HULL PHONE: 513-765-3847 E-MAIL: [email protected] USE GROUP: CONSTRUCTION TYPE: SEISMIC CATEGORY: DRINKING FOUNTAIN: PUBLIC ACCESS: SERVICE SINK: M-301 MECHANICAL SCHEDULES SIMON PROPERTY GROUP 225 WEST WASHINGTON ST. INDIANAPOLIS, IN 46204 CONTACT: LUCRETIA SAPPINGTON PHONE: 317-263-7125 E-MAIL: [email protected] Store Planner IBC 2012 IPC 2012 NEC 2011 IMC 2012 IECC 2009 TAS WATER CLOSETS: LAVATORIES: Landlord LUXOTTICA 4000 LUXOTTICA PLACE MASON, OH 45040 CONTACT: SCOTT YOUNG PHONE: 940-445-3122 E-MAIL: [email protected] BUILDING CODE: PLUMBING CODE: ELECTRICAL CODE: MECHANICAL CODE: ENERGY CODE: ACCESSIBILITY: ROOM NAME DETAIL ID SHEET NUMBER 101 NAME NUMBER M-702 MECHANICAL SPECIFICATIONS E-101 POWER PLAN E-102 LIGHTING PLAN & LIGHTING LEGEND E-501 ELECTRICAL DETAILS & ABBREVIATIONS E-601 ELECTRICAL SINGLE LINE DIAGRAM AND PANEL SCHEDULES E-701 ELECTRICAL SPECIFICATIONS E-702 ELECTRICAL SPECIFICATIONS 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM AREA CALCULATIONS A1 MEP Consultant Purchasing Coordinator A LUXOTTICA 4000 LUXOTTICA PLACE MASON, OH 45040 CONTACT: DAWN SPARKS PHONE: 513-765-3947 E-MAIL: [email protected] 1 A1 SHREMSHOCK ENGINEERING, INC. 7400 W. CAMPUS RD. SUITE 150 NEW ALBANY, OH 43054 CONTACT: JEROMY PERRY PHONE: 614-545-4550 E-MAIL: [email protected] 2 3 ELEVATION ID SHEET NUMBER A-201 A-201 FLOOR 0'-0" 4 LOCATION ELEVATION STOREFRONT FRONTAGE: SHEET NUMBER ELEVATION ID A7 NORTH 1 1 5 6 SALES AREA STOCK ROOM: 435 SF 21 SF TOTAL: LEASE TOTAL 456 SF 446 SF 8 SGH STORE #: 6078 DRAWN BY: ALW REVIEWED BY: MLH/JMA AUTHORIZED FOR: 22 LF COVER SHEET G-001 MATERIAL NUMBER 7 LA PLAZA MALL F BUILDING CODE AT LANDLORD NOTES REV. 1 MALL KEY PLAN 9 10 11 12 13 14 4 5 6 ABBREVIATIONS K AMERICANS WITH DISABILITIES ACT ACCESSIBILITIES GUIDELINES ABOVE FINISH FLOOR CENTERLINE CEILING CERAMIC TILE COLUMN CONCRETE CONTINUOUS DIAMETER DIMENSION DETAIL DRAWINGS ELECTRICAL CONTRACTOR EXISTING EXPOSED EQUAL FIXTURE CONTRACTOR GYPSUM BOARD GENERAL CONTRACTOR A.F.F. CL. CLG. CT. COL. CONC. CONT. DIA. DIM. DTL. DWGS. E.C. EX. OR (E) EXP. EQ. F.C. G.B. G.C. J G.A.T. M.C. N.I.C. O.C. OPP. O/ P.C. REQ. R. SCH. SIM. TYP. U.N.O. V.I.F. VERT. W.C. WD. W.R. A1 H B1 NOMINAL SIZE MATERIAL FINISH MATERIAL FINISH FIRE RATING HDWR. (E)ROLLING GRILLE ENTRY SEE PLANS EXISTING EXISTING EXISTING EXISTING - A CLOSET 2'-8"W. x 7'-0"H. x 1 3/4" HOLLOW METAL P-3 HOLLOW METAL P-3 - - EXISTING TO REMAIN EXISTING TO REMAIN B - UNFINISHED DOOR AND FRAME SUPPLIED, INSTALLED AND FINISHED BY G.C. (U.N.O.) PUSH: HAGER HINGE CO.: #40R, 4"W x 16"H, FINISH US26D PULLS: HAGER HINGE CO.: #4L, WROUGHT DOOR PULL 1" DIA. x 12"H, FINISH US26D DOOR CLOSER: CORBIN RUSSWIN DC4610 SERIES PARALLEL ARM WITH HOLD OPEN. HINGES: BOMMER 1 1/2 PAIR PER LEAF, 4-1/2" x 4-1/2", NO. BB5004N STANDARD WEIGHT, AVERAGE FREQUENCY, FULL MORTISE, BALL BEARING HINGE, FINISH: STAINLESS STEEL KICKPLATE: STANLEY DOOR SYSTEM; FULL WIDTH x 10"H x 1/8" STAINLESS STEEL INSTALLED 1" FROM BOTTOM OF DOOR FLOOR MOUNTED STOP: IVES MODEL #FS13US26 CAST BRASS, CHROME PLATED (OR EQUAL) SILENCERS: G.C. TO SELECT F USER: JGRAY PLOTTED: 7/16/2015 - 4:03 PM D B1 A1 SE D 7'-0" C1 D1 VERIFYING EXISTING DOOR HARDWARE TYPE AT LOCATIONS WHERE EXISTING EXTERIOR/ENTRANCE DOORS ARE TO REMAIN. ANY NON-GENERIC/BRANDED DOOR HARDWARE TO BE IDENTIFIED AND REPLACEMENT MUST BE COORDINATED WITH LUXOTTICA PROJECT MANAGER. A1 SCALE: DOOR SCHEDULE 1 2 3 4 NOTE: VERIFY ALL ITEMS IN THIS SCHEDULE FOR ACCURACY PRIOR TO BEGINNING CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE PROJECT MANAGER IMMEDIATELY. 11 REMARKS BUILDING PERMIT T PERMIT APPLIED FOR BY TENANT / OBTAINED AND PAID FOR BY CONTRACTOR TEMPORARY BARRICADES (WITH GRAPHIC) T T TEMPORARY CONSTRUCTION WINDOW VINYL - - G.C. TO COORDINATE WITH LANDLORD AND BOSTON BARRICADE DIVISION 03 - CONCRETE FURN. INST. REMARKS CONCRETE SLAB E G.C. TO VERIFY AS REQUIRED, NOTIFY P.M. OF CONDITION OF SLAB B DIVISION 05 - METALS FURN. INST. STRUCTURAL STEEL E TENANT SEPARATION WALL E DIVISION 08 - OPENINGS 12 13 14 1. THE CONTRACTOR SHALL HAVE EVIDENCE OF CURRENT WORKER'S COMPENSATION INSURANCE ON FILE IN COMPLIANCE WITH LOCAL CODES. 2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL SHOW EVIDENCE OF ALL INSURANCE REQUIREMENTS. 3. THE CONTRACTOR SHALL BE FAMILIAR WILL ALL LANDLORD REQUIREMENTS AND SHALL BE RESPONSIBLE FOR COMPLIANCE WITH REQUIREMENTS. THE CONTRACTOR SHALL INVESTIGATE LOCAL CODES AND PROCEDURES AND SHALL COMPLY WITH REQUIREMENTS. 4. SIGN CONTRACTOR TO OBTAIN SIGN PERMITS FROM BUILDING DEPARTMENT AS APPLICABLE. 5. CONTRACTOR SHALL CONTACT LANDLORD REPRESENTATIVE BEFORE CONSTRUCTION COMMENCES. 6. ALL CONDUIT, EQUIPMENT AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST SAFETY RULES AND REGULATION OF ALL AUTHORITIES AND AGENCIES HAVING JURISDICTION. REMARKS FURN. INST. REMARKS THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE DURATION OF THE WORK ALL EXITS, EXIT LIGHTING, FIRE PROTECTION DEVICES AND ALARMS IN CONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES. 9. DURING ALL PHASES OF WORK DO NOT DISTURB THE DELIVERIES AND FUNCTIONS OF ADJACENT AND NEIGHBORING TENANTS. FURN. INST. REMARKS STOREFRONT SYSTEM - - N/A ROLLING GRILLE E E 10. EACH CONTRACTOR SHALL LEAVE THE SITE IN A NEAT, CLEAN AND ORDERLY CONDITION UPON THE COMPLETION OF THEIR WORK ON A DAILY BASIS. AREA OF WORK TO BE DUSTED, SWEPT AND MOPPED TO SAME CONDITION AS START OF WORK. ALL WASTE OR EXCESS MATERIALS SHALL BE REMOVED FROM THE SITE PROMPTLY. THE G.C. SHALL BE RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL TRASH, INCLUDING TRASH GENERATED FROM OWNER FURNISHED ITEMS AND BY OWNERS CONTRACTORS FOR THE DURATION OF THE PROJECT. DOOR LOCK CORES AND KEYS T T/G COORDINATE LOCKSMITH IF NOT COMPATIBLE WITH TENANT KEY SYSTEM 11. ALL EXISTING WORK NOT IN THIS SCOPE OF WORK SHALL BE MAINTAINED IN ITS ORIGINAL CONDITION, U.N.O. DIVISION 09 - FINISHES FURN. INST. REMARKS 12. PROTECT WORK FROM DAMAGE RESULTING FROM THIS WORK. TENANT SEPARATION PARTITIONS (GYPSUM WALLBOARD) E E/G G.C. TO VERIFY, PATCH/REPAIR AS REQUIRED STOREFRONT BULKHEAD E E/G G.C. TO VERIFY, PATCH/REPAIR AS REQUIRED CEILING E/G E/G STOREFRONT TILE - - CERAMIC TILE FLOORING T G GROUT G G MALL FLOORING E E ALUMINUM BASE MOULDING (HPL-06) T T MILLWORKER TO COORDINATE WITH G.C. WALK-OFF MAT (RECESSED) - - N/A DIVISION 10 - SPECIALTIES FURN. INST. REMARKS SIGNAGE E E (E) STOREFRONT SIGNAGE TO REMAIN 17. NO MATERIAL SUBSTITUTIONS WILL BE ALLOWED UNLESS NOTED OTHERWISE OR SUBMITTED IN WRITING TO AND APPROVED BY THE OWNER'S REPRESENTATIVE. AWNING - - N/A 18. ANY WOOD CONSTRUCTION SHALL BE FIRE RETARDANT TREATED, U.N.O. DIVISION 12 - FURNISHINGS FURN. INST. REMARKS MILLWORK FLOOR FIXTURES T T G.C. TO COORDINATE WITH VENDOR U-RAIL GRAPHIC HANGING SYSTEM (TBD) T G LOOSE FIXTURES/PROPS T T G.C. TO COORDINATE WITH VENDOR. G.C. TO UNBOX/ UNWRAP AND STORE IN B.O.H. MISCELLANEOUS EQUIPMENT T G SEE EQUIPMENT SCHEDULE GRAPHICS GRID - - N/A TOILET ACCESSORIES - - N/A DIVISION 21 - FIRE SUPPRESSION FURN. INST. REMARKS SPRINKLER SYSTEM MODIFICATIONS G COORDINATE WITH LANDLORD AND TENANT. LAYOUT TO ALIGN WITH LIGHT FIXTURES 21. G.C. SHALL COORDINATE WORK PERFORMED BY OTHER CONTRACTORS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE OWNER'S ATTENTION (VERBALLY AND DOCUMENTED IN WRITING) BEFORE PROCEEDING WITH WORK. FIRE SPRINKLER MAIN E REMARKS 22. SHOULD A CONFLICT EXIST BETWEEN THE CONSTRUCTION DOCUMENTS AND/OR THE SPECIFICATIONS, THE OWNER'S REPRESENTATIVE SHALL BE INFORMED (VERBALLY AND DOCUMENTED IN WRITING) OF THIS DISCREPANCY IMMEDIATELY, AT WHICH TIME OWNER'S REPRESENTATIVE SHALL PROVIDE DIRECTION ON HOW TO PROCEED. Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL 14. G.C. SHALL BE RESPONSIBLE FOR COORDINATION WITH OWNERS REPRESENTATIVE TO PROVIDE A TIMELY ARRIVAL OF ALL MATERIALS, EQUIPMENT AND OTHER SUCH ITEMS TO BE UTILIZED ON THIS PROJECT. G.C. SHALL NOTIFY OWNER'S REPRESENTATIVE IN WRITING WITHIN 5 DAYS OF DATE OF APPROVED WORK AUTHORIZATION OF THOSE ITEMS THAT MAY BY READILY AVAILABLE. IF NOTIFICATION IS NOT PROVIDED TO THE OWNER'S REPRESENTATIVE, THE CONTRACT ACCEPTS RESPONSIBILITY FOR THE PROPER ORDERING AND FOLLOW-UP OF SPECIFIED ITEMS AND WILL PURSUE WHATEVER MEANS NECESSARY AT NO ADDITIONAL COST TO OWNER. N/A 1/8" GROUT JOINTS TYP. 15. CONTRACTOR TO ENSURE AVAILABILITY OF ALL SPECIFIED ITEMS SO AS NOT TO CREATE A HARDSHIP TO THE OWNER AND NOT DELAY PROGRESS OF THE WORK. NO EXTENSION OF TIME SHALL BE PERMITTED. G 16. CONTRACTOR SHALL BE RESPONSIBLE TO RECEIVE, INVENTORY, STORE, AND SECURE ANY OWNER FURNISHED ITEMS SUPPLIES AND DELIVERED TO THE JOBSITE, OR OTHER AGREED UPON LOCATION, AND FORWARD THE RECEIVING DOCUMENTS TO THE OWNER. 19. G.C. SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTOR'S BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OR RESPONSIBILITY IN PERFORMANCE OF WORK. 20. ALL CONTRACTORS, SUBCONTRACTORS, VENDORS AND MATERIAL SUPPLIES SHALL BE RESPONSIBLE FOR REVIEWING THE COMPLETE SET OF DOCUMENTS AS SHOWN IN THE SHEET INDEX. FAILURE TO REVIEW CONSTRUCTION DOCUMENTS WILL NOT RELIEVE ANY CONTRACTORS, SUBCONTRACTORS, VENDORS OR MATERIAL SUPPLIES FOR PERFORMING WORK OR PROVIDING MATERIALS REQUIRED FOR THE COMPLETION OF THIS PROJECT AS DEFINED WITHIN THE DOCUMENTS AT TIME OF BID. - - WATER METER - - 23. INSPECT SITE AND VERIFY FIELD DIMENSIONS BEFORE COMMENCING WITH CONSTRUCTION. NOTIFY OWNER'S REPRESENTATIVE AND LANDLORD IMMEDIATELY IF THERE ARE ANY DISCREPANCIES. GAS METER - - 24. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DRAWINGS. PLUMBING FIXTURES - - DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING FURN. INST. 25. ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER OTHER DRAWINGS FOR LAYOUT DIMENSIONS AND NUMBER OF ITEMS PROVIDED. UPON DISCOVERY OF DISCREPANCIES BETWEEN ARCHITECTURAL DRAWINGS AND ENGINEERING DRAWINGS, OWNER SHALL BE IMMEDIATELY NOTIFIED IN WRITING. AIR CURTAIN - - EXHAUST FANS AND VENTING - - HVAC UNIT E - HVAC CONTROLS E G ENERGY MANAGEMENT SYSTEM (EMS) - - HVAC DISTRIBUTION DUCTWORK, DIFFUSERS E/G G CURBS & SUPPORTS FOR CONDENSING UNITS E - 29. COLUMN CENTER LINE (OR GRID LINES) ARE SHOWN FOR DIMENSIONS. VERIFY EXACT LOCATION IN FIELD. SMOKE EVACUATION SYSTEM & CONTROLS - - 30. OWNER'S REPRESENTATIVE AND TENANT ARE THE SAME FOR PURPOSES OF THESE DRAWINGS. DUCT SMOKE DETECTORS - - DIVISION 26 - ELECTRICAL FURN. INST. ELECTRICAL SERVICE, CONDUIT, WIRING E ELECTRIC METER, SEPARATE E REMARKS 26. IF ANY ERRORS OR OMISSIONS APPEAR IN THE CONTRACT DOCUMENTS, CONTRACTOR SHALL NOTIFY OWNER IN WRITING OF SUCH ERRORS OR OMISSIONS. 27. DIMENSIONS SHOWN ON PLANS ARE TO FACE OF CMU, CONCRETE COLUMNS OR GRID LINES AND FACE OF GYPSUM BOARD UNLESS NOTED OTHERWISE. REUSE AND RELOCATE EXISTING THERMOSTAT 28. THE CONTRACTOR SHALL REVIEW ALL CONSTRUCTION DOCUMENTS, VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND CONFIRM WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSIONS, ETC. SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT FOR CLARIFICATION PRIOR TO PERFORMANCE OF ANY WORK IN QUESTION. AIR BALANCING TO BE COMPLETED BY GC REMARKS 31. ALL OPENINGS, FLASHING, COUNTER FLASHING, AND EXPANSION JOINTS SHALL BE WATERTIGHT IN EXTERIOR STORES. G 120/208V, 3PH, 4W, 100A FUSED DISCONNECT TO REMAIN AS IS. GC TO REPLACE IF EXISTING FUSED DISCONNECT NOT IN GOOD WORKING ORDER. 32. ALL OPEN JOINTS, PENETRATIONS AND OTHER OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED OR WEATHER-STRIPPED TO LIMIT AIR LEAKAGE IN EXTERIOR STORES. G EXISTING ELECTRICAL METER TO REMAIN AS IS, GC TO COORDINATE WITH LANDLORD'S REPRESENTATIVE AND LOCAL UTILITY COMPANY. 33. ALL SAW CUTTING AND CORING LOCATIONS SHALL BE REVIEWED AND COORDINATED WITH THE LANDLORD PRIOR TO CUTTING/ CORING. (1) 120/208V, 3PH, 4W, 100A, MCB. GC TO PROVIDE CIRCUIT BREAKERS AND ANY MODIFIICATION TO PANEL BOARD AS INDICATED IN PANEL SCHEDULE. 34. G.C. IS RESPONSIBLE FOR MAINTAINING REQUIRED FIRE RATINGS AND FIRE PROOFING IN ALL INSTANCES. ELECTRICAL PANEL G G TRACK CURRENT LIMITING PANEL - - EMERGENCY LIGHTING G G EXIT SIGNS G G GC TO PROVIDE JUNCTION BOX TO TIE INTO LANDLORD'S FIRE ALARM SYSTEM, HORN AND STROBES. ALL FIRE ALARM SYSTEM DEVICES BE BY 'EDWARDS EST' ALL FIRE ALARM WORK TO BE DONE BY LANDLORD APPROVED CONTRACTOR 'GLOBAL RISK CONSULTANTS' AT TENANT CONTRACTOR'S EXPENSE. G G LIGHT FIXTURES G G LAMPS G G SOUND SYSTEM AND SPEAKERS T G G.C. TO COORDINATE WITH VENDOR TENANT TELEPHONE EQUIPMENT T G G.C. TO COORDINATE WITH VENDOR TELEPHONE CONDUIT TO SPACE E - TELEPHONE WIRING TO SPACE E - SECURITY - FACILITY/HARDWARE & WIRING/VECTOR (ALARMS) T T G.C. TO COORDINATE WITH VENDOR SECURITY - PRODUCT/HARDWARE & WIRING/- A1 (CAMERAS) T T G.C. TO COORDINATE WITH VENDOR TRAFFIC COUNTER T T G.C. TO COORDINATE WITH VENDOR 7 35. GC TO COVER THE STOREFRONT WINDOWS AND DOORS WITH KRAFT PAPER FROM THE TIME THE BARRICADE IS REMOVED UNTIL THE STORE OPENS. 36. GC TO SCHEDULE A PRE-TURNOVER CLEANING FOR WEDNESDAY MORNING AND A FINAL DETAIL CLEANING TUESDAY MORNING AT 9:00 AM PRIOR TO OPENING. FIRE ALARM SYSTEM 6 CONSULTANT PROJECT # 150343 13. WHEN CONTRACTOR ACCEPTS DELIVERY OF ALL ITEMS NOTED ON PLANS WHETHER IN CONTRACT OR NOT IN CONTRACT, THE G.C. SHALL BE RESPONSIBLE FOR LOSS AND/OR DAMAGE TO THESE ITEMS. WATER AND SEWER STUB 5 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 8. PROVIDE ADDITIONAL EXIT SIGNS AND FIRE EXTINGUISHERS IN TYPE , NUMBER, AND LOCATION AS DIRECTION BY THE AUTHORITIES HAVING JURISDICTION. SEE PLANS E 3'-0" NO TU 7'-0" NO TU (E) 1. 3'-0" 2'-8" 7'-0" B SE D PER PLAN 10 GENERAL NOTES DIVISION 01 - GENERAL FURN. INST. PER PLAN P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\G-002_06078.dwg LAYOUT: G-002 E C 9 7. LOCATION A A ITEM FRAME INFORMATION G.C. TO REPLACE ANY MISSING OR DAMAGED HARDWARE G T = TENANT/OWNER G = GENERAL CONTRACTOR L = LANDLORD E = EXISTING GYPSUM CEILING TILE MECHANICAL CONTRACTOR NOT IN CONTRACT ON CENTER OPPOSITE OVER PLUMBING CONTRACTOR REQUIRED RADIUS SCHEDULED SIMILAR TYPICAL UNLESS NOTED OTHERWISE VERIFY IN FIELD VERTICAL WATER CLOSET WOOD WATER RESISTANT DOOR INFORMATION MARK 8 RESPONSIBILITY SCHEDULE FURNISHED BY A.D.A.A.G. 7 LA PLAZA MALL 3 AT 2 INSTALLED BY 1 8 37. TIMECLOCK TO BE SET TO "ON" 30 MINUTES PRIOR TO MALL OPENING AND 30 MINUTES AFTER MALL CLOSE. 38. INSTRUCTIONS FOR MODIFYING THE TIMECLOCK OPERATION TO BE LEFT WITH THE STORE AND DETAILED MANAGEMENT AT TURNOVER. 39. GC IS RESPONSIBLE TO ACCEPT DELIVERY OF ALL PROPS - UN-BOX, SORT AND COUNT. THE SUPERINTENDENT SHOULD GIVE A CHECK-IN SHEET NOTING ALL DISCREPANCIES TO THE PROJECT MANAGER UPON ARRIVAL FOR THE PUNCHLIST. 40. ALL CARDBOARD SHOULD BE REMOVED FROM THE SITE PRIOR TO TURNOVER, HOWEVER, THE PROPS SHOULD BE LEFT IN THE PLASTIC TO PROTECT FROM DAMAGE/DUST. SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 DRAWN BY: ALW/CHC/EDS REVIEWED BY: MLH/JMA AUTHORIZED FOR: RESPONSIBILITY & DOOR SCHEDULE G-002 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 1. K TENANT TO SUPPLY GRAPHICS. COORDINATE WITH LANDLORD BARRICADE SIGNAGE REQUIREMENTS 13'-3"± A.F.F. 14 GENERAL NOTES ELEVATION SHOWN IS A REPRESENTATION OF INTENT. ACTUAL VINYL GRAPHIC IS TO BE SUBMITTED BY BOSTON BARRICADE TO LANDLORD FOR REVIEW BY EX PEDITOR TO PRODUCTION AND INSTALLATION. TURN IN BARRICADE 13 2. TURN IN BARRICADE 3. T.O. BARRICADE 4. 5. J 6. 7. TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKERS ON THE JOB AND TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON ON, ABOUT, OR ADJACENT TO THE PREMISES. COMPLY WITH ALL LAWS, ORDINANCES, CODES, RULES AND REGULATIONS RELATIVE TO SAFETY AND THE PREVENTION OF ACCIDENTS. THIS DEMOLITION PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET OF WORKING DRAWINGS. DO NOT REMOVE OR DEMOLISH ANYTHING WITHOUT VERIFYING AND COORDINATING WITH ALL GENERAL TRADES AS TO HOW THEY RELATE TO THE OVERALL PROJECT. ALL CONTRACTORS SHALL BE RESPONSIBLE FOR DEMOLISHING AND REMOVING EXISTING CONSTRUCTION WHICH WILL INTERFERE WITH THEIR NEW WORK AND ANY TEMPORARY BRACING OR PERMANENT SUPPORT STRUCTURES. WHEN EXISTING ELECTRICAL SERVICE, POWER, AND LIGHTING IS REMOVED, STUB BACK AND CAP AS REQUIRED IN AREAS BETWEEN EXISTING CONDITIONS AND NEW WORK. ANY EXISTING ROOFTOP AIR CONDITIONING UNIT, ROOF CURBS AND ALL ASSOCIATED DUCTWORK, GRILLES, DIFFUSERS, HANGER, CONTROL WIRING, ELECTRICAL WIRING, CONDUITS, AND CONDUIT HANGERS, IF APPLICABLE PER PROJECT STORE SITE, TO REMAIN UNLESS NOTED OTHERWISE ON PLANS. REFER TO MECHANICAL DRAWINGS. IN ACCORDANCE WITH THE DRAWINGS, THOSE ITEMS WHICH ARE REMOVED, AND ARE NOT RELOCATED OR REUSED, SHALL BE DISPOSED OF BY THE G.C. PROVIDE AND INSTALL TEMPORARY BARRICADE. COORDINATE REQUIREMENTS WITH LANDLORD. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150343 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL TEMPORARY BARRICADE H 0'-0" A.F.F. FINISH FLOOR 1. BOSTON BARRICADE SHALL CONSTRUCT A TEMPORARY BARRICADE PER LL REQUIREMENTS. 2. BARRICADE IS TO BE 100% COMPLETE AND READY FOR GRAPHICS TO BE INSTALLED NOT MORE THAN TWO DAYS AFTER CONSTRUCTION START. G.C. TO CONTACT OWNERS REPRESENTATIVE UPON COMPLETION TO COORDINATE GRAPHICS INSTALLATION. 3. G.C. IS RESPONSIBLE FOR MAINTAINING BARRICADE DURING CONSTRUCTION. BARRICADE PROVIDED BY BOSTON BARRICADE 4'-0"± (UNFOLDED) 4'-0"± (UNFOLDED) 22'-1"± 4. REMOVE BARRICADE WHEN 100% OF STOREFRONT IS COMPLETE ON THE EVENING BEFORE G.C.'S PUNCHLIST IS COMPLETED, PRIOR TO OWNER VERIFICATION, AND AFTER LANDLORD APPROVAL IS RECEIVED. CARE IS TO BE TAKEN WHEN DISASSEMBLING AND REMOVING BARRICADE. ON INTERIOR SIDE (STORE SIDE), PAPER WINDOWS WITH WHITE CONSTRUCTION PAPER OVER GLAZING ONLY. TRIM 1/2" OFF EDGES AND TAPE CONTINUOUSLY AROUND PERIMETER WITH WHITE TAPE. G.C. IS TO RESTORE NEUTRAL PIER(S), MALL FLOORING AND BULKHEAD TO A 'LIKE NEW' CONDITION AND FINISH. G G1 SCALE: BARRICADE ELEVATION F 20'-8" ADJACENT TENANT (N.I.C.) E 1 12 TYP. 6. NOT USED 7. EXISTING MILLWORK & VALANCE LIGHTING TO BE REMOVED. 5'-6" 13. NOT USED. 14. NOT USED. - 15. EXISTING TENANT SEPARATION WALL TO REMAIN. 16. EXISTING THERMOSTAT TO BE REMOVED. 17. EXISTING ELECTRICAL PANEL AND WALL TO BE REMOVED. 8 EXISTING SOFFIT TO REMAIN & BE REWORKED. SEE SHEET A-104 FOR NEW CONDITION. 22'-1" 5 9 10 G1 19. NOT USED. A-101 20. NOT USED. 1 12 7 22. (E) INSULATED ROOF DRAIN AT ±14'-11 1/2" AFF TO REMAIN MALL COMMON AREA 2 21 25 21. (E) ELECTRICAL CONDUIT RACK AT ±15'-0" AFF TO REMAIN 15'-0" 11 C REMOVE EXISTING CASHWRAP, FLOOR CASEWORK, AND ASSOCIATED ELECTRICAL & DATA HOOK-UP. REMOVE WIRING/ CONDUIT BACK TO SOURCE. 12. REMOVE EXISTING TRACK. 22 12 15 5. 11. SALVAGE EXISTING SPRINKLER HEADS FOR RELOCATION. REFER TO SHEET A-104 FOR NEW LOCATIONS. 3 23. (E) RTU AND SUPPLY/RETURN TRUNKS TO REMAIN 24. (E) SPRINKLER MAIN AND PIPES TO REMAIN 18 TYP. 25. (E) TENANT DUCTWORK AT ±13'-8" TO REMAIN / BE REWORKED. SEE MECHANICAL SHEETS 24 B 10" LAYOUT: A-101 P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\A-101_06078.dwg PLOTTED: 7/16/2015 - 4:03 PM USER: JGRAY FROM LEASE LINE 25 23 ADJACENT TENANT (N.I.C.) EXISTING ROLLING GRILLE ENTRY DOOR TO REMAIN. G.C. TO HAVE DOOR VENDOR SERVICE AND CLEAN ROLLING GRILL. 10. REMOVE EXISTING GYP. BD. CEILING, LIGHT FIXTURES, ACCESS PANEL, EXIT SIGNS, SPRINKLER HEADS, AND MECHANICAL DIFFUSERS ABOVE IN THIS AREA REFER TO SHEET A-104 FOR NEW CONDITIONS AND RELOCATIONS. - 16 4'-0" 1 3. 9. REMOVE EXISTING FLOORING MATERIAL. PATCH AND PREPARE FLOOR AS REQ'D TO PROVIDE SMOOTH FLOOR FOR NEW FLOORING PER PLAN ON SHEET A-103. CAP EXISTING MECHANICAL, PLUMBING AND ELECTRICAL SERVICES FLUSH WITH EXISTING SLAB AS REQ'D. 7 D BARRICADE BY BOSTON BARRICADE. REFER TO VENDOR SHOP DRAWINGS 8. EXISTING STOREFRONT SIGNAGE TO REMAIN. 9" 15 2. 4. NOT USED. 4" 20'-4" LEASE LINE AT - 1. 17 1 12 7 SGH STORE #: 6078 15 DRAWN BY: ALW GRAPHICAL KEY REVIEWED BY: MLH/JMA EXIST. TO BE REMOVED U.N.O. EXIST. TO REMAIN U.N.O. AUTHORIZED FOR: DEMOLITION / LEASE PLAN NORTH A A1 A-101 DEMOLITION / LEASE PLAN 1 2 SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM - ADJACENT TENANT (N.I.C.) SCALE: LA PLAZA MALL KEY NOTES 3 4 5 6 7 8 9 10 11 12 13 14 2 3 4 5 6 7 8 ACCESSORY ID DESCRIPTION MODEL # MANUFACTURER 1 GRAB BAR B-5806x42 BOBRICK 2 GRAB BAR B-5806x36 BOBRICK 3 VERTICAL GRAB BAR B-5806x18 BOBRICK 4 MIRROR B-165 1836 BOBRICK ABOVE LAV. REFER TO G6/A-502 5 MIRROR B-165 2460 BOBRICK RESTROOM DOOR K J 6 TOILET TISSUE DISPENSER B-5543 BOBRICK 7 UTILITY HOOK B-2116 BOBRICK 8 HOOK STRIP B-232x24 BOBRICK 9 MOP HOLDER B-223x24 BOBRICK REMARKS NON-LOCKING 10 EQUIPMENT NAME DESCRIPTION MODEL # MANUFACTURER LOCKERS(#) EMPLOYEE LOCKERS 36168/ 36368 LOCKERS.COM SAFE SMALL DROP SLOT SAFE UC-025K SENTRYSAFE MICRO MICROWAVE OVEN M01108SST AVANTI FRIDGE REFRIGERATOR RM3316B AVANTI XxYxZ PIPP SHELVING STORAGE SHELVING 11 REMARKS COLOR: GRAY, LOCKS: 33390, # = NUMBER OF 12" WIDE UNITS BOLTED TO FLOOR BY G.C. KT1024 SIMPLE HUMAN 11 LAVATORY FAUCET 7803.101 AMERICAN STANDARD X = WIDTH, Y = DEPTH, Z = HEIGHT, SEE A7/A-502 PIPP STAPLES #180969 TOILET ACCESSORY SCHEDULE EQUIPMENT SCHEDULE SCALE: 9. 10. 11. D E S U OT GRAB BAR (E) GRAB BAR (E) T O N 1'-7" MIN. 4'-0" 4'-0" 7"-9" 3'-4" 3'-4" N 3'-0" 3'-0" GRAB BAR (E) G 3'-4" 6'-2" 3'-0" MIN CL 2'-0" 12" MIN MIN 6'-0" PLAN VIEW 1'-4" MIN 1'-6" MAX MIRROR (E) MIRROR (N) TOILET TISSUE DISPENSER (N) UTILITY HOOK (N) HOOK STRIP (N) D E S U MOP HOLDER (N) 14 COORDINATE CORE DRILLING WITH MALL OPERATIONS MANAGER PRIOR TO BEGINNING WORK. PREPARE THE FLOOR SLAB AND PROCURE MATERIALS REQUIRED AT THE ENTRANCE TO PRODUCE A FLUSH CONDITION BETWEEN THE TENANT STORE CLOSURE LINE AND THE EXISTING MALL FLOORING. INSTALL ALL FINISH FLOORING (I.E.: CARPET, WOOD, TILE) AND ALL FINISH WALL MATERIALS BEHIND AND UNDER ALL MILLWORK. ADEQUATE ACCESS PANELS OR DOORS SHALL BE INCORPORATED INTO TENANT WORK FOR INSPECTION SERVICE AND REPLACEMENT OF BOTH LANDLORD AND TENANT EQUIPMENT, COORDINATE PLACEMENT WITH LANDLORD'S ON-SITE REPRESENTATIVE. PROVIDE 3/4" FIRE RETARDANT PLYWOOD BEHIND ALL ELECTRICAL AND TELEPHONE PANELS, PAINT TO MATCH WALL COLOR FINISH PRIOR TO HARDWARE INSTALLATION. PROVIDE EXPANSION BETWEEN ALL NEW WALLS AND THE EXISTING ROOF STRUCTURE ABOVE. PATCH/REPAIR ALL SURFACES (WALLS, FLOOR, CEILING, ETC.) AFFECTED BY DEMOLITION WORK. TRANSITIONS BETWEEN DISSIMILAR FLOOR MATERIALS TO BE SMOOTH AND FLUSH. REFER TO SHEET A-502 FOR FOR APPLICABLE FLOOR TRANSITION DETAILS. ALL FINISH MATERIALS SHALL BE INSTALLED PER MANUFACTURER'S STANDARD WRITTEN DETAILS AND SPECIFICATIONS. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE A LEVEL 4 GYP. BD. FINISH ON ALL NEW AND EXISTING WALLS. SEAL CONTROL JOINTS IN CONCRETE FLOORS. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150343 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL KEY NOTES 1. LEASE LINE. 2. NOT USED. 3. EXISTING TENANT SEPARATION WALL TO REMAIN. G.C. SHALL PATCH/ REPAIR GYP BD. AS REQUIRED. MAINTAIN REQUIRED RATING. PAPER TOWEL DISPENSER (N) 4. CONCRETE MUST BE LEVEL AND CLEAN OF ANY FOREIGN MATERIALS PRIOR TO INSTALLING NEW FINISHED FLOORING. G.C. TO PERFORM MOISTURE BARRIER TEST BEFORE INSTALLING ANY FLOORING - REFER TO SPECIFICATIONS FOR MOISTURE TEST PROCEDURES 5. LINE OF SOFFIT ABOVE. 6. ELECTRICAL DISTRIBUTION EQUIPMENT. REFER TO ELECTRICAL DRAWINGS. G4 SCALE: 4. 8. J8 1'-0" 2. 7. J4 3'-6" 1. 3. COLOR: BLACK 13 GENERAL NOTES 6. PAPER TOWEL DISPENSER H 12 5. 10 SCALE: 9 4'-0" 1 7. NOT USED. TOILET ACCESSORY MOUNTING HEIGHTS 8. NOT USED. 9. NOT USED. 10. TECH RACK & SECURITY SHELVES FOR EQUIPMENT/MUZAK. REFER TO D1/A-502 SIM. 11. 3'-6" CLEAR FLOOR SPACE IN FRONT OF ELECTRICAL PANELS 13. NOT USED. 14. PHONE BOARD. SEE D1/A-502 - 15. NOT USED. 20'-8" 16. SHORT WALL 9'-0" A.F.F. G.C. TO SEAL WALL CAVITY ABOVE WITH PLYWOOD AS NECESSARY 4" AT 20'-4" ADJACENT TENANT (N.I.C.) E 1 9" 3 LA PLAZA MALL 12. NOT USED. F PLOTTED: 7/16/2015 - 4:03 PM USER: JGRAY B D - 1 SALES 3 ADJACENT TENANT (N.I.C.) 100 E1 4 A-401 22'-1" 16'-312" HOLD 5 912" HOLD A FE 6 1 LEASE LINE OVERHEAD LINEWORK WALL CONSTRUCTION WALL INFILL CONSTRUCTION TO MATCH EXISTING EXISTING WALL CONSTRUCTION SAFE 11 10" B A 14 CLOSET 3 - 1 A1 101 4'-014"± 14'-318" V.I.F. HOLD SUNGLASS HUT LA PLAZA MALL GRAPHICAL KEY 2'-014" V.I.F. 10 4'-43 4"± 15'-0" 1'-6" MALL COMMON AREA (N.I.C.) HOLD B SIM. C 5'-107 8" 16 B1 P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\A-102_06078.dwg LAYOUT: A-102 5'-6" (E) A1 - 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 DOOR WITH TYPE AND SIZE - SEE G-002 & D4/A-502 DRAWN BY: ALW (E) A1 ADJACENT TENANT (N.I.C.) EXISTING DOOR WITH TYPE AND SIZE - SEE G-002 REVIEWED BY: MLH/JMA AUTHORIZED FOR: X A NORTH FE PARTITION TYPE - SEE A8/A-503 FIRE EXTINGUISHER. FOR EXACT LOCATIONS AND REQUIREMENTS CONSULT WITH LOCAL FIRE DEPARTMENT INSPECTOR A1 SCALE: A-102 FLOOR PLAN 1 FLOOR PLAN 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 P-3 FLOOR GR-01 K T-02 CERAMIC TILE ATLAS CONCORDE ATLAS CONCORDE EVOLVE COLOR: EVOLVE IRON FINISH: MATTE SIZE: 60x60 - 23 5/8”x23 5/8” GROUT SPACING: 1/8" P-6 7 8 9 10 11 ACRYLIC PAINT BENJAMIN MOORE REGAL SELECT COLOR: 2126-30 ANCHOR GRAY SHEEN: FLAT C-01 12 1. PROVIDE AND INSTALL FIRE EXTINGUISHERS AS DIRECTED BY THE FIRE MARSHAL. (SUGGESTED LOCATIONS ON PLAN. IF EXISTING AND NOT CURRENT, CONTACT P.M. 2. EXAMINE ALL SURFACES TO BE PAINTED UNDER THIS CONTRACT AND SEE THAT THE WORK OF OTHER TRADES HAVE BEEN LEFT OR INSTALLED IN A SATISFACTORY CONDITION TO RECEIVE PAINT OR SPECIFIED FINISH. 3. MAINTAIN ALL FINISHES IN THE STORE, WALLS, FLOOR AND CEILING PRIOR TO TURNOVER. TOUCH-UP ALL CORNER BEADS, WALLS, CEILING AND FLOORING AS REQUIRED PRIOR TO TURNOVER AND ANY DAMAGE CAUSED BY OTHER TRADES INCLUDING MILLWORKER. 4. SEE SHEET A-201 FOR SALES ELEVATIONS AND FINISH DESIGNATIONS. 5. G.C. TO CLEAN EXISTING FLOORING TO 'LIKE NEW' CONDITION. VINYL BASE JOHNSONITE 4" H. x 1/8" THICK COLOR: 38-PEWTER CONSULTANT PROJECT # 150343 Shremshock Architects, Inc. KEY NOTES 1. NOT USED 2. BACK OF HOUSE TECH RACK & SECURITY SHELVES FOR EQUIPMENT/MUZAK. REFER TO A-502 3. TYPICAL CLOSET FINISHES: FLOOR: VT-01, BASE: VB-01, WALLS: P-2, NON-SALES DOORS: P-3, CEILING: OPEN-PAINT P-6. WALL ACRYLIC PAINT BENJAMIN MOORE REGAL SELECT COLOR: 2132-10 BLACK SHEEN: EGGSHELL P-2 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect 24" X 24" SUSPENDED CEILING US GYPSUM MARS CLIMAPLUS SQUARE EDGE COLOR: WHITE 050 ACT GRID: 15/16" GRID - DX/DXL (SALES) - WHITE DECOMETAL LAMINATE APPLIED TO WOOD BASE. FORMICA FINISH: BRUSHED ALUMINIUM H 14 (E) GYPSUM BOARD C-02 P-1 13 GENERAL NOTES CEILING BASE VB-01 6 STOREFRONT VINYL TILE ARMSTRONG COMMERCIAL FLOORING STANDARD EXCELON IMPERIAL TEXTURE COLOR: 51861 SOFT WARM GRAY SIZE: 12" x 12" x 1/8" HPL-06 5 ACRYLIC PAINT BENJAMIN MOORE REGAL SELECT COLOR: 2132-10 BLACK SHEEN: SEMI-GLOSS GROUT FOR CERAMIC TILE LATTICRETE COLOR:45 RAVEN VT-01 J 4 SEAL 4. NOT USED ACRYLIC PAINT BENJAMIN MOORE REGAL SELECT COLOR: PM-1 SUPER WHITE SHEEN: EGGSHELL 5. H.C. ACCESSIBLE CASHWRAP. 6. NOT USED 7. (54) PRODUCT STORAGE TRAYS. FURNISHED BY OWNER, INSTALLED BY G.C. 8. NOT USED 9. NEW UTILITY HOOK. REFER TO J4/A-102 FOR ADDITIONAL INFORMATION 10. NOT USED 11. NOT USED G 12. NOT USED 13. NOT USED 14. START TILE (FULL TILE) CENTERED ON ENTRY AS SHOWN G1 SCALE: 15. NOT USED FINISH MATERIAL SCHEDULE 16. NOT USED 17. FIXTURE SHOWN IS IN THE LOCATION FOR STORE HOURS OF OPERATION AND INSIDE TENANT LEASE LINE. TENANT TO MOVE FIXTURE INSIDE LINE OF ROLLING GRILLE WHEN STORE IS CLOSED. - 20'-8" 4" AT 20'-4" ADJACENT TENANT (N.I.C.) 9" E STOR. PNL. USER: JGRAY PLOTTED: 7/16/2015 - 4:03 PM C 01 TVSAFE J9 3 5'-6" EQ. CL H1 A-201 E1 MALL COMMON AREA (N.I.C.) H6 5 22'-1" E6 T 02 GR 01 SUNGLASS HUT LA PLAZA MALL 3'-6" 2 G9 14 7'-0" 9 02 T- CT-1 15'-0" 3'-6" 2'-014" EQ. GO GO CW 3.1R ACCESSORY ADJACENT TENANT (N.I.C.) FS 1.0 100 SP 10.5L 3'-0" SP 10.4(18) SP 10.5R 4'-0" 3'-0" SALES D - 7 SP 10.1C 10 .6 SP 14.0-3 SP 11.4(18) SP 11.4(6) SP 11.5R SP 11.5L SP 11.1C SP 11.0C SP 11.0C 17 7 B 10" P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\A-103_06078.dwg LAYOUT: A-103 SP CAPACITY CALCULATIONS 101 ADJACENT TENANT (N.I.C.) A NORTH A1 FINISH/FIXTURE PLAN 1 2 3 4 5 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM - CLOSET SCALE: 6 LA PLAZA MALL F 7 8 9 10 11 FIXTURE ID THEME CT-HC CT-1 CT-2 FS 1.0 GO 1.0 SP 10.0C SP 10.1C SP 11.0C SP 11.1C STORY PANEL 12 SGH STORE #: 6078 FIXTURE QUANTITY 1 0 1 0 1 0 5 1 2 1 1 FIXTURE CAPACITY 0 0 0 0 52 144 108 54 108 54 -26 TOTAL 13 TOTAL FACINGS 0 0 0 0 52 0 540 54 216 54 -26 890 14 DRAWN BY: ALW REVIEWED BY: MLH/JMA AUTHORIZED FOR: FINISH / FIXTURE PLAN A-103 1 2 3 4 5 6 7 8 9 10 11 12 13 14 GENERAL NOTES 1. 2. K 3. 4. 5. 6. 7. J 8. 9. REFER TO LIGHTING SPECIFICATIONS SCHEDULE FOR ADDITIONAL INFORMATION. GRID LAYOUT FOR ACOUSTICAL CEILING TILE TO BE CENTRALLY LOCATED WITHIN RETAIL SPACE AS INDICATED AT PLAN LAYOUT UNLESS SPECIFICALLY NOTED OTHERWISE. REFER TO PLAN LAYOUT FOR EQUAL/EQUAL DIMENSIONS TO BE MAINTAINED. IT SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR AIMING TRACK HEADS PER SGH STANDARDS. ELECTRICAL CONTRACTOR TO CONTACT LUXOTTICA PM FOR FOCUSING DIRECTIVE IF NEEDED. G.C. IS RESPONSIBLE TO PATCH/REPAIR ALL GYP.BD. CEILING SURFACES AFFECTED BY DEMOLITION/NEW CONSTRUCTION. EXISTING GYP.BD. CEILING SURFACES TO RECEIVE A FRESH COAT OF PAINT UPON COMPLETION OF SCOPE OF CEILING WORK. LIGHTING INSTALLER IS RESPONSIBLE TO TOUCH UP ANY AREAS DAMAGED BY THEIR WORK. CENTER CEILING GRID & CEILING DEVICES U.N.O. SPRINKLER HEADS SHOWN FOR REFERENCE ONLY. FIRE PROTECTION CONTRACTOR TO DETERMINE ACTUAL AMOUNT AND LOCATION OF HEADS. SPRINKLER HEADS SHOULD BE LOCATED SYMMETRICALLY IN THE CEILING AND SURFACE MOUNTED WHEN APPLICABLE. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150343 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL KEY NOTES H 1. LOCATION OF TRAFFIC COUNTER (SHOPPER TRAK). REFER TO E-102. 2. PREFERRED SPEAKER LOCATION. SPEAKER TO MATCH CEILING COLOR. 3. LOCATION OF WIRELESS ACCESS POINT. REFER TO E-102. 4. LIGHT TRACK TO BE MOUNTED ON FACE OF EXISTING SOFFIT. 5. END OF LIGHT TRACK TO ALIGN WITH EXISTING SOFFIT. 6. SECURITY CAMERAS. REFER TO E-102 7. NOT USED 8. START TILE SHOWN HATCHED EXISTING SOFFIT TO BE REWORKED. VERTICAL FACE OF G NEW CONSTRUCTION TO ALIGN WITH ADJACENT EXISTING GYP. BD. SOFFIT. 10. EXISTING OVERHEAD ROLLING GRILLE DOOR. - 20'-8" 4" AT 20'-4" ADJACENT TENANT (N.I.C.) E D7 9" A-502 PLOTTED: 7/16/2015 - 4:03 PM USER: JGRAY 1 A3W A3W A3W A3W A3W A3W TW6'-0" 3 2 C4W TW10'-0" 5'-6" FIXTURE EXTENTS BELOW OF STOREFRONT OPENING MALL COMMON AREA (N.I.C.) 2 TW TB 9 A3W 10" A3B - ADJACENT TENANT (N.I.C.) 101 2x2 LED RECESSED MOUNT RETURN AIR GRILLE B2 2x4 LED RECESSED MOUNT B3 RECEPTACLE DUPLEX OPEN TO DECK VARIES (P-6) CLOSET B1 EXHAUST FAN 5 B RETURN AIR GRILLE SUPPLY DIFFUSER A3W A3W A3W A3W A3W A3W S S C 4 1'-10" C4W TC 618" C4W S A3W 6 AP 1 11" TW4'-0" S C SYMBOLS LEGEND / GRAPHICAL KEY X1A A3W A3W 100 8 A3W 22'-1" SALES TW12'-0" 10 C4W 15'-0" C4W C4W (E) SOFFIT (P-2) 9'-11" AFF 5 - A3W A3W A3W S C A3W A3W A3W ACT - C-02 11'-0" AFF 6 " '-6 9 4'-0" A3W A3WA3WA3W A3W TW12'-0" A3W A3W A3W A3W C A3W 4'-0" S A3W A3W A3W A3W A3WA3W A3W A3W A3W ADJACENT TENANT (N.I.C.) B3 P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\A-104_06078.dwg LAYOUT: A-104 S C D - 2 4'-0" 6 X1 RECESSED ADJUSTABLE DOWN LIGHT (BLACK) EXIT LIGHT (WHITE) X1B EXIT LIGHT (BLACK) ADJUSTABLE TRACK HEAD (WHITE) ADJUSTABLE TRACK HEAD (BLACK) C1B C4W A LIGHT TRACK w/ LENGTH (BLACK) RECESSED ADJUSTABLE DOWN LIGHT 4'-1 LED STRIP SUSPENDED AT 13'-0" A.F.F. CONCEALED SPRINKLER HEAD UPRIGHT SPRINKLER HEAD X1AW EXIT LIGHT - CEILING MOUNTED X1AB EXIT LIGHT - CEILING MOUNTED LIGHT TRACK w/ LENGTH C1W C4B X2 X3 X4 EXIT SIGN EXIT & EMERGENCY LIGHT COMBINATION EMERGENCY LIGHT REMOTE POWER SUPPLY RECESSED ADJUSTABLE DOWN LIGHT (WHITE) RECESSED ADJUSTABLE DOWN LIGHT (BLACK) NORTH A1 SCALE: AP WIRELESS ACCESS POINT TC TRAFFIC COUNTER (E) EXISTING (R) RELOCATION S C SECURITY CAMERA S SPEAKER 2 SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 DRAWN BY: ALW REVIEWED BY: MLH/JMA AUTHORIZED FOR: REFLECTED CEILING PLAN A-104 REFLECTED CEILING PLAN 1 LA PLAZA MALL F 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 GENERAL NOTES ON BOTH SIDES OF DOOR & FRAME P 3 K TURN IN WALL B.O. CEILING 11'-0" AFF P 1 P 1 P P 2 2 P 1 1. REFER TO OWNER'S SIGNAGE STANDARD FOR ADDITIONAL SIGN INFORMATION. SIGNAGE WORK TO BE SUBMITTED UNDER SEPARATE PERMIT. 2. SEE SHEET A-103 FOR FINISH MATERIAL SCHEDULE B.O. CEILING 11'-0" AFF A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150343 B.O. SOFFIT 9'-11" AFF T.O. LOW WALL 9'-0" AFF Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect J HPL 06 FINISH FLOOR 0'-0" AFF SP 14.0-3 HPL 06 H ON BOTH SIDES OF DOOR & FRAME P 3 SP 10.0C SP 10.5L SP 10.0C FINISH FLOOR 0'-0" AFF SP 10.6 HPL 06 SP 11.5L 11.0C SP 11.4(18) SP 11.1C 11.0C HPL 06 SP 11.5R SP 11.4(6) H6 H1 ELEVATION SCALE: G P ELEVATION 2 P B.O. CEILING 11'-0" AFF P 1 2 B.O. CEILING 11'-0" AFF B.O. SOFFIT 9'-11" AFF B.O. SOFFIT 9'-11" AFF OPEN TO MALL F STOR. PNL. FINISH FLOOR 0'-0" AFF FINISH FLOOR 0'-0" AFF SP 10.6 SP 10.0C SP 10.0C SP 10.1C SP 10.0C AT HPL 06 SP 10.8R SP 10.4(18) HPL 06 E E6 E1 USER: JGRAY PLOTTED: 7/16/2015 - 4:03 PM P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\A-201_06078.dwg LAYOUT: A-201 SCALE: ELEVATION SCALE: LA PLAZA MALL SCALE: SEAL ELEVATION D C SIGNAGE MATRIX B TYPE ID QTY. REMARKS BARRICADE LIFESTYLE GRAPHIC 1 BY BARRICADE VENDOR STOREFRONT - - BY SIGN VENDOR BLADE SIGN SGH.BL-1 SGH.BL-2 - BY SIGN VENDOR CRASH GRAPHICS SGH-CGL - BY SIGN VENDOR SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 DRAWN BY: ALW REVIEWED BY: MLH/JMA A A6 A1 SCALE: ELEVATION 1 SCALE: 2 3 4 5 ELEVATION 6 7 8 9 10 11 BACKWRAP SGH.BW - BY MILLWORKER IDENTIFICATION SIGN SGH.ID - BY MILLWORKER VINYL DOT PATTERN - - BY SIGN VENDOR 12 13 14 AUTHORIZED FOR: ELEVATIONS A-201 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 K B.O. MALL CEILING 14'-3" A.F.F. CONSULTANT PROJECT # 150343 B.O. BULKHEAD 13'-3" A.F.F. (E) STOREFRONT SIGN TO REMAIN Shremshock Architects, Inc. (E) STOREFRONT CONSTRUCTION AND FINISHES TO REMAIN. G.C. TO PATCH & REPAIR TO 'LIKE NEW' CONDITION J 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect T.O. STOREFRONT ENTRY 9'-11" A.F.F. H (E) STOREFRONT CONSTRUCTION AND FINISHES TO REMAIN. G.C. TO PATCH & REPAIR TO 'LIKE NEW' CONDITION G.C. TO PATCH & REPAIR (E) STOREFRONT CONSTRUCTION TO 'LIKE NEW' CONDITION. PAINT P-2 TO MATCH EXISTING STOREFRONT COLOR (E) FIRE STROBE TO REMAIN (E) TENANT STOREFRONT OPENING W/ ROLLING GRILLE TO REMAIN G.C. TO PATCH & REPAIR (E) STOREFRONT CONSTRUCTION TO 'LIKE NEW' CONDITION. PAINT P-2 TO MATCH EXISTING STOREFRONT COLOR G SEAL LEASE LINE LEASE LINE (E) NEUTRAL PIER TO REMAIN (E) NEUTRAL PIER TO REMAIN F (E) STOREFRONT BASE TO REMAIN (E) STOREFRONT BASE TO REMAIN G.C. TO HAVE DOOR VENDOR SERVICE AND CLEAN ROLLING GRILLE. 18'-3 3/8" 1'-10 1/8" AT 1'-11 5/8" 22'-1" E E1 USER: JGRAY PLOTTED: 7/16/2015 - 4:03 PM P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\A-401_06078.dwg LAYOUT: A-401 (ALT) SCALE: LA PLAZA MALL FIN. FLOOR 0'-0" STOREFRONT ELEVATION D C SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM B SGH STORE #: 6078 DRAWN BY: ALW REVIEWED BY: MLH/JMA AUTHORIZED FOR: STOREFRONT ELEVATION A A1 SCALE: A-401 NOT USED 1 2 3 4 5 6 7 8 9 10 11 12 13 14 5 J-CHANNEL G.C. TO MECHANICALLY FASTEN (EVERY 12"-18") THE TOP, BOTTOM, AND ONE SIDE J-CHANNEL, SLIDE MIRROR IN (WITH MIRROR MASTIC) AND ATTACH THE OTHER SIDE J-CHANNEL. GC TO USE ANCHORS AS REQUIRED TO SECURELY FASTEN. 9 10 11 BOBRICK B-1651836 MIRROR WITH STAINLESS STEEL CHANNEL FRAME PROVIDE IN-WALL BLOCKING AS REQUIRED DOOR FLASH PATCH BY G.C. 18" MIRROR BY G.C. J J4 J9 DOOR MIRROR DETAIL 36" FLOOR TRANSITION VCT TO PORCELAIN TILE 37 8" NOT USED SCALE: RESTROOM MIRROR DETAIL LINE OF EXISTING CONCRETE SLAB PHONE BOARD/SECURITY ELEVATION D E S U RESTROOM RESTROOM BRAILLE SIGN PER 1991 ADA REQ'TS 17-19" 4'-8" 9" 27" MIN 29" MIN 33"-36" 40" MAX ANSI APPROVED E.S. PLASTIC NEMA RATED SELF EXTINGUISHING ADHESIVE MOUNTED O N T O N REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS. FASTENING TO STRUCTURE ABOVE TO COMPLY WITH LANDLORD AND OR LOCAL BUILDING DEPARTMENT REQUIREMENTS. SCALE: SUSPENDED GYP. BD. CEILING DETAIL FRAMING AS REQUIRED. REFER TO SPECIFIC DETAILS AND STRUCTURAL DRAWINGS. D E S U T CONCEALED CONTINUOUS HINGE N T O D E S U REFER TO CEILING PLAN VARIES 5/8" GYP. BD. 2'-1114" 1'-05 8" SCREWDRIVER OPERATED LATCH. VARIES REFER TO CLG PLAN 1'-65 8" 1'-1114" FRONT 3 SIDE 3 4" SHELF SPACING AND BIN ARRANGEMENTS A7 TYPICAL LAVATORY/SHELVING ELEVATION 3 DISABLED ACCESS SIGNAGE 4 5 SCALE: 6 A11 PIPP SHELVING 7 SUNGLASS HUT LA PLAZA MALL SGH STORE #: 6078 1'-6" SCALE: ATTACH WITH #8 SHEET METAL SCREWS. 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM 3'-1114" LAVATORY, REFER TO PLUMBING DRAWINGS 2 G.C. IS TO PROVIDE A ONE-HOUR FIRE RATED CEILING SYSTEM (WHEN-REQUIRED). BRACKET D E S U A4 1 5/8" GYP. BD. 'TYPE X' METAL TRIM A1 SCALE: N T O INSTALLATION ON VERTICAL WALL TO BE SIMILAR. ALL FASTENER REQUIREMENTS AND SPECIFICATIONS ARE THE SAME. 12" 12" 12" 12" 12" 12" 12" O.C. O.C. O.C. O.C. O.C. O.C. O.C. 8'-0" 2'-0" 0.C. INSULATE HOT WATER AND DRAIN PIPING 1 1/2" CHANNEL 4'-0" O.C. MAX. 20 GA. METAL STUD WITH 1 5/8" FLANGE AND 1/2" LIPS. (MIN.) STANDARD STORES (LOW SEISMIC) IBC SEISMIC DESIGN CATEGORIES A,B&C ACOUSTICAL CEILING TILE NOTE: ALL SIGNAGE SHALL CONFORM WITH ADA ACCESSIBILITY GUIDELINES, INCLUDING BUT NOT LIMITED TO PROPORTION, COLOR CONTRAST AND RELIEF AND GRADE 2 BRAILLE REQUIREMENTS. BLUE A SCALE: D E S U ALIGN 3'-0" O N T LINE OF EXISTING CONCRETE SLAB 1/2" SHELF VARIES REFER TO PLAN CL PROVIDE LATEX LEVELING COMPOUND AS REQUIRED TO CREATE FLUSH CONDITION AT THRESHOLD. D11 7'-1118" C MIRROR, REFER TO G6/A-502 1 1/2" MAX VARIES SCALE: METAL FURRING CHANNEL CLIP INTERMEDIATE DUTY SUSPENDED GRID SYSTEM CROSS "T" MEMBER @ 2'-0" OR 4'-0" O.C. (REFER TO SPECIFIC CEILING TYPE). D7 3'-0" WIDE X 2" DEEP X 3/4" THICK WHITE MELAMINE SHELVING, FINISHED ON ALL SURFACES WITH WHITE DOUBLE SLOTTED BRACKETS & STANDARDS. FASTEN SHELVES TO BRACKETS REFER TO G4/A-102 FOR TOILET ACCESSORY MOUNTING HEIGHTS,TYP. VINYL TILE 24" O.C. MAX. SPACING WALL OR SOFFIT FRAMING AND FINISHES. REFER TO SPECIFIC DETAILS. HOLLOW METAL JAMB / HEAD DETAIL HANGER SPACING 4'-0" O.C. MAX. INTERMEDIATE DUTY SUSPENDED GRID SYSTEM MAIN RUNNER @ 2'-0" O.C. WALL MOLDING. SIZE TO MATCH SIZE OF MAIN RUNNERS HOLLOW METAL FRAME D4 SCALE: ALUMINUM THRESHOLD FLOOR TRANSITION CONCRETE TO VINYL MINIMUM OF 3 TIGHT TURNS AT ALL WIRES. MINIMUM OF 3 TIGHT TURNS AT ALL WIRES. ACOUSTICAL CEILING TILES 24" W. X 48" H. PHONE BOARD 2'-0" 1'-6" 3" 10" 3'-0" SAFE SCALE: REFER TO CEILING PLAN VARIES QUAD OUTLET TECH RACK G12 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EA. WAY. AND MAX. 8" FROM ALL EDGES. DSL D1 34" MIN LAYOUT: A-502 D T O NOTE: PREPARE EXISTING CONCRETE SLAB AS REQUIRED TO PROVIDE LEVEL TRANSITION TO MALL FLOORING 12 GA VERTICAL SUPPORT WIRE @ 4'-0" O.C. EA. WAY. AND MAX. 8" FROM ALL EDGES. 8" MAX. AT PERIMETER CLEAR SPACE FOR ELECTRICAL PANEL 12 PORT PATCH PANEL QUAD OUTLET BEHIND TECH RACK D E US SEAL LA PLAZA MALL SEE WALL TYPE FOR FRAMING A66 PHONE BLOCK P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\A-502_06078.dwg FLOOR TRANSITION TILE TO TILE N FLOOR TRANSITION TILE TO MALL CONFORM TO BASIC MINIMUM REQUIREMENTS ESTABLISHED IN ASTM C636 5/8" GYPSUM BOARD MONITOR Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect DOOR (E) MALL FLOORING. FIELD VERIFY TYPE. FASTENING TO STRUCTURE ABOVE TO COMPLY WITH LANDLORD AND OR LOCAL BUILDING DEPARTMENT REQUIREMENTS. 40" MIN 60" MAX E THIN SET MORTAR BED B.O. (E) ROOF DECK / STRUCTURE OR (E) FLOOR DECK / STRUCTURE 24" W. x 18" D. SHELVING RATED TO 100 LBS (TYP.) ON 24" WHITE DOUBLE SLOTTED STANDARDS.SCREW SHELVES TO BRACKETS MONITOR, KEYBOARD AND MOUSE ON SHELF SCALE: CONSULTANT PROJECT # 150343 AT NOT USED SCALE: G9 F PLOTTED: 7/16/2015 - 4:03 PM SCALE: A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 TILE FLOORING PER PLANS & SCHEDULE 1/8" THICK ZINC TRANSITION STRIP FURNISHED AND INSTALLED BY TILE CONTRACTOR. G.C. TO ADJUST SETTING BED AS REQUIRED TO ACHIEVE FLUSH TRANSITION G6 ELEVATION SHOWN IS FOR REFERENCE ONLY. REFER TO PLAN SHEETS FOR ACTUAL LOCATION OF SAFE, TECH RACK AND PHONE BOARD. USER: JGRAY J12 NOTE: PREPARE EXISTING CONCRETE SLAB AS REQUIRED TO PROVIDE LEVEL TRANSITION TO MALL FLOORING G4 T O NOTE: PREPARE EXISTING CONCRETE SLAB AS REQUIRED TO PROVIDE LEVEL TRANSITION TO MALL FLOORING TILE FLOORING PER PLANS & SCHEDULE G D E US 1/8" THICK ZINC TRANSITION STRIP FURNISHED AND INSTALLED BY TILE CONTRACTOR. THIN SET MORTAR BED 412" SCALE: 14 LINE OF EXISTING CONCRETE SLAB NOTE: PREPARE EXISTING CONCRETE SLAB AS REQUIRED TO PROVIDE LEVEL TRANSITION TO MALL FLOORING LOCKING DEVICES AUTOMATICALLY SECURE MIRROR TO CONCEALED WALL HANGER WHEN IT IS LOWERED INTO FINAL POSITION, TYP. G1 13 N TILE FLOORING PER PLANS & SCHEDULE LINE OF EXISTING CONCRETE SLAB SCALE: H B 12 1/8" THICK ZINC TRANSITION STRIP FURNISHED AND INSTALLED BY TILE CONTRACTOR. VINYL TILE ATTACH WALL HANGER TO IN-WALL BLOCKING W/ #8 X 1 1/2" F/H MTL SCREWS WHERE REQUIRED, TYP. SCALE: 8 1 " 4 T 7 36" MIN. TAPER D E S U K O N 6 212" 4 US ED 3 T 2 NO 1 SCALE: 8 9 10 4" 12 13 REVIEWED BY: MLH/JMA AUTHORIZED FOR: ACCESS PANEL WITH METAL DOOR. FINISH TO MATCH CEILING. CEILING MOUNTED ACCESS PANEL METAL FLUSH MOUNTED 11 DRAWN BY: ALW GENERAL DETAILS A-502 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 LIGHT GAUGE FRAMING - CROSS REFERENCE GUIDE K 25 GA. ------ 18 MIL 22 GA. ------ 27 MIL 20 GA. ------ 33 MIL 18 GA. ------ 43 MIL 3/4 " A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 16 GA. ------ 54 MIL 14 GA. ------ 68 MIL 12 GA. ------ 97 MIL CONSULTANT PROJECT # 150343 SCALE: DETAIL AT LATERAL BRACING SUPPORT NOTE: CONSTRUCT WALL PER UL ASSEMBLY REQUIREMENTS SHOWN ON ARCHITECTURAL DRAWINGS. INSTALL SLIP TRACK AND FIRE-SAFING MATERIALS PER MANUFACTURER'S RECOMMENDATIONS TO ACHIEVE ONE HOUR FIRE RATING F 18 GA DEEP LEG TRACK WITH 2" FLANGE. (DEPTH TO MATCH VERTICAL STUD DEPTH) ATTACH TO STRUCTURE W/ (2) #12 SCREWS AT 16" O.C. 3/4" MAX SE D 3/4" MAX NO 162T125-27 162T125-33 250T125-33 250T200-33 250T125-43 250T200-43 362T125-33 362T200-33 362T125-43 362T200-43 600T125-33 600T200-33 600T125-43 600T200-43 TYPICAL HAT (FURRING) CHANNELS 7/8", 25 GA. FURRING CHANNEL 7/8", 22 GA. FURRING CHANNEL 087F125-18 087F125-27 3 5/8" 20 GA. TRACK (TYP.) I.C.B.O. # ESR 3016 FINISH FLOOR 0'-0" A4 1 SCALE: 2 3 16" 28'-6" 16 16" 30'-0" SEAL STUD DESIGNATION STUD DEPTH FLANGE WIDTH 362S162-33 3-5/8" 1-5/8" 362S162-43 3-5/8" 1-5/8" 362S162-54 3-5/8" 1-5/8" STUD DESIGNATION STUD DEPTH FLANGE WIDTH 362S162-33 3-5/8" 1-5/8" SIM. SE D 6" STUD GAUGE STUD SPACING 20 16" 15'-0" 18 16" 16'-6" 16 16" 18'-0" STUD GAUGE STUD SPACING MAXIMUM HEIGHT TO DIAGONAL BRACE MAXIMUM HEIGHT TO DIAGONAL BRACE 15'-0" 16" 20 362S162-43 3-5/8" 1-5/8" 18 16" 16'-0" 362S162-54 3-5/8" 1-5/8" 16 16" 17'-0" NOTES: 1. DESIGN BASED ON ALLOWABLE DEFLECTION OF L/360. 2. DESIGN BASED ON FY = 33 KSI FOR 3 5/8" & 6" STUDS LESS THAN 16 GAUGE. FY = 50 KSI FOR 3 5/8", 16 GAUGE & 6", 16 GAUGE STUDS. 3. PROVIDE HORIZONTAL BRIDGING @ 4'-0" O.C. MAX PER MANUFACTURER'S RECOMMENDATIONS. 4. DESIGN BASED ON MINIMUM 5 PSF LATERAL LOAD, OR LATERAL SEISMIC LOAD, WHICHEVER CONTROLS. 5. TABLE IS VALID FOR (1) LAYER OF GYPSUM BOARD EACH FACE. 6. FOR STUD DESIGNATIONS REFER TO E8/A-503. STUD SIZE MATRIX SEISMIC DESIGN CATERGORIES A AND B REFER TO DIAGONAL BRACING ON SHEET A-504 PER PLAN (1) LAYER 5/8" GYPSUM BOARD (SEE FINISH SCHEDULE FOR APPLIED FINISH) SCHEDULED CEILING REFER TO CEILING PLAN (1) LAYER 5/8" GYPSUM BOARD (SEE FINISH SCHEDULE FOR APPLIED FINISH) METAL STUDS ANCHORED TO EXISTING CONSTRUCTION AS REQUIRED CONTINUOUS TOP TRACK SCHEDULED CEILING REFER TO CEILING PLAN (1) LAYER 5/8" GYPSUM BOARD (SEE FINISH SCHEDULE FOR APPLIED FINISH) G4 G4 G4 A-503 A-503 A-503 4 7/8" A4 A-503 METAL STUD - REFER TO METAL STUD SCHEDULE FOR SIZE AND SPACING. FOR 1 HOUR RATED WALL USE MIN. 25 GA. GALV. STEEL (1) LAYER 5/8" "TYPE X" GYP. BOARD CONT. 3 5/8" METAL BOTTOM RUNNER ATTACH TO CONC. FLOOR SLAB AS REQUIRED SCHEDULED BASE EACH SIDE LINE OF FINISH FLOOR C A COLUMN DETAIL 18 1-5/8" METAL STUD - REFER TO METAL STUD SCHEDULE FOR SIZE AND SPACING A4 A-503 SIM. SCHEDULED BASE LINE OF FINISH FLOOR 3 5/8" METAL STUDS AT 16" O.C. MAX. METAL STUD - REFER TO METAL STUD SCHEDULE FOR SIZE AND SPACING 4 7/8" (1) LAYER 5/8" "TYPE X" GYP. BOARD A4 A-503 CONT. 3 5/8" METAL BOTTOM RUNNER ATTACH TO CONC. FLOOR SLAB AS REQUIRED SCHEDULED BASE EACH SIDE LINE OF FINISH FLOOR 3 5/8" METAL STUD CONSTRUCTION WITH 5/8" GYPSUM BOARD EACH SIDE. EXTEND GYP. BD. IN NON-SALES TO ROOF DECK ABOVE. GYP. BD. IN SALES AREA TO STOP 6" ABOVE ADJACENT CEILING B 2 1/2" METAL STUD CONSTRUCTION WITH 5/8" GYPSUM BOARD ON ROOM SIDE. A A1 REFER TO METAL STUD SIZE MATRIX ON E11/A-503 OR SEISMIC SHEET IF USED. 3 5/8" METAL STUD CONSTRUCTION WITH 5/8" "TYPE X" GYPSUM BOARD EACH SIDE TO 6" ABOVE ADJACENT CEILING. 3 5/8" METAL STUD CONSTRUCTION WITH 5/8" "TYPE X" GYPSUM BOARD ON ONE SIDE TO 6" ABOVE ADJACENT CEILING. A8 FLOOR ATTACHMENT DETAIL 4 5 SCALE: 6 SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 DRAWN BY: ALW REVIEWED BY: MLH/JMA .177 DIA. HILTI POWDER ACTUATED FASTENER w/ 3/4'" EMBEDMENT AT 24" O.C. ICBO #ESR 1663 SCALE: 1-5/8" 6" PLAN VIEW #8 SCREWS EA. SIDE OF STUD TO TRACK (TYP.) A1 6" 600S162-54 EXISTING CONSTRUCTION NO TU PLAN VIEW METAL STUD FRAMING REFER TO NOTES AND PLANS FOR SIZE, GAUGE, AND SPACING B 600S162-43 SCALE: 3 5/8" METAL STUDS AT 16" O.C. MAX. C 26'-6" 20 IN ADDITION, THE SPACING OF THE TOP AND BOTTOM WALL TRACK CONNECTIONS TO THE EXISTING STRUCTURE SHALL BE REDUCED TO 6" O.C. MAX., AND DIAGONAL SPACING SHALL BE REDUCED TO 32" O.C. D4 DEFLECTION TRACK WALL ATTACHMENT TO METAL DECK 20'-6" 16" 1-5/8" DBL STUD METAL STUD SCHEDULE SECTION @ TOP D4 16" 1-5/8" E11 SEISMIC DESIGN CATEGORIES A & B 16 3-5/8" 6" Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect #8 SCREWS @ 8" O.C. E8 A-503 19'-0" NOTE: AT LOCATIONS WHERE A STUD WALL SUPPORTS BOTH SALES AND NON-SALES SHELVING, THE STUDS SHOWN IN THE TABLE BELOW SHALL BE "DOUBLED UP" AS FOLLOWS: UNLESS NOTED, LIGHT GAUGE FRAMING CONNECTIONS SHALL BE MADE USING #8 SCREWS. SEE DETAIL A1/A-504 FOR DIAGONAL BRACING CONNECTIONS. AT LOCATIONS WHERE SHEATHING MATERIAL IS PLACED AGAINST THE SCREW HEADS OF LIGHTGAUGE METAL FRAMING CONNECTIONS, PANCAKE HEAD SCREWS SHALL BE USED SO THAT THE SHEATHING MATERIAL REMAINS STRAIGHT AND SMOOTH. (ONE HOUR FIRE-RATED) 18 362S162-54 SECTION @ BASE PLOTTED: 7/16/2015 - 4:03 PM 1 5/8", 22 GA. TRACK w/ 1 1/4" LEG 1 5/8", 20 GA. TRACK w/ 1 1/4" LEG 2 1/2", 20 GA. TRACK w/ 1 1/4" LEG 2 1/2", 20 GA. TRACK w/ 2" LEG 2 1/2", 18 GA. TRACK w/ 1 1/4" LEG 2 1/2", 18 GA. TRACK w/ 2" LEG 3 5/8", 20 GA. TRACK w/ 1 1/4" LEG 3 5/8", 20 GA. TRACK w/ 2" LEG 3 5/8", 18 GA. TRACK w/ 1 1/4" LEG 3 5/8", 18 GA. TRACK w/ 2" LEG 6", 20 GA. TRACK w/ 1 1/4" LEG 6", 20 GA. TRACK w/ 2" LEG 6", 18 GA. TRACK w/ 1 1/4" LEG 6", 18 GA. TRACK w/ 2" LEG 17'-6" 16" 600S162-33 ROOF DECK VERIFY HEIGHT IN FIELD CONCRETE SLAB USER: JGRAY 1200S162-54 1200S162-97 SCALE: (1) #8 WAFERHEAD SCREW IN EACH FLANGE OF EACH VERT STUD. INSTALL PER MANUFACTURERS RECOMMENDATIONS (NON-RATED) 12", 16 GA. STUD w/ 1 5/8" FLANGE 12", 12 GA. STUD w/ 1 5/8" FLANGE SECTION @ BASE LAYOUT: A-503 D SCALE: P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\A-503_06078.dwg 1" DEFL. GAP SEE SCHEDULES FOR FINISHES AND STUD SIZES 1000S162-43 1000S162-54 LIGHT GAUGE FRAMING SCREW CONNECTIONS 3/4" MAX 3/4" MAX 1" DEFL. GAP TU E 18 GA DEEP LEG TRACK WITH 2" FLANGE. (DEPTH TO MATCH VERTICAL STUD DEPTH) ATTACH TO STRUCTURE W/ (2) #12 SCREWS AT 16" O.C. 10", 18 GA. STUD w/ 1 5/8" FLANGE 10", 16 GA. STUD w/ 1 5/8" FLANGE 16" 20 LA PLAZA MALL G4 800S162-43 800S162-54 1-5/8" AT G 8", 18 GA. STUD w/ 1 5/8" FLANGE 8", 16 GA. STUD w/ 1 5/8" FLANGE 1-5/8" 3-5/8" MAXIMUM WALL HEIGHT OR MAXIMUM HEIGHT TO DIAGONAL BRACE 6" MIN. 1 12" x 16 GA. COLD ROLLED CHANNEL LATERAL BRACING 362S162-33 362S162-43 600S162-33 600S162-43 3-5/8" 362S162-43 STUD SPACING SECTION @ TOP NOT USED 3 5/8", 20 GA. STUD w/ 1 5/8" FLANGE 3 5/8", 18 GA. STUD w/ 1 5/8" FLANGE 6", 20 GA. STUD w/ 1 5/8" FLANGE 6", 18 GA. STUD w/ 1 5/8" FLANGE 362S162-33 STUD GAUGE PLAN VIEW H1 2 1/2", 20 GA. STUD w/ 1 5/8" FLANGE 2 1/2", 18 GA. STUD w/ 1 5/8" FLANGE FLANGE WIDTH SECTION @ BASE METAL STUD FLANGE STUD WIDTH THICKNESS =1.625" =43 MIL (18 GA.) =1 5/8" NEW SSMA DESIGNATION (STEEL STUD MANUFACTURERS ASSOCIATION) 250S162-33 250S162-43 FORMER STANDARD DESIGNATION STUD DEPTH STUD DESIGNATION TYPICAL STRUCTURAL STUDS AND TRACKS FRAMING SCREWS (4) TYPICAL 2" x 2" 16 GA. CLIP ANGLE 14" LESS THAN STUD WIDTH METAL STUD 6" MIN. H SCALE: " 1/2 STUD (S=STUD) DEPTH (T=TRACK) =3.625" =3 5/8" FIRST LEVEL STARTS @ 4'-0" ABOVE FLOOR J " 3/4 3/4 " " 3/4 - SECTION @ TOP 8'-0" O.C. FULL WALL HEIGHT 3 5/8", 18 GA STRUCTURAL METAL STUD = 7 FRAMING DETAILS A-503 PARTITION TYPES 8 AUTHORIZED FOR: 9 10 11 12 13 14 1 K 2 3 4 5 6 7 8 9 (2)-1/4" DIA CONC ANCHORS (KWIK BOLT TZ BY HILTI) WITH 1 3/4" EMBED EXIST CONC FLOOR SLAB 11 12 13 14 EXIST CONC FLOOR SLAB 2"x2"x0'-6" LG, 12 GA FRAMING CLIP W/(3)-#12 SCREWS EA LEG (2)-1/4" DIA CONC ANCHORS (KWIK BOLT TZ BY HILTI) WITH 1 3/4" EMBED 10 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 EXIST CONC FLOOR SLAB (3)-#12 SCREWS D E S U T NO DIAG BRACE 2"x2"x1'-0" LG, 12 GA FRAMING CLIP J CONSULTANT PROJECT # 150343 DIAG BRACE PERPENDICULAR TO ROOF BEAMS. EXIST STL BM 2"x2"x0'-6" LG, 12 GA FRAMING CLIP (CENTER CLIP IN "UP" FLUTE OF DECK). (3)-#12 SCREWS DIAG BRACE Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect BEFORE INSTALLING ANCHORS, CONTRACTOR SHALL VERIFY WITH MALL MANAGEMENT THAT ATTACHMENT SHOWN IS ACCEPTABLE. SEAL DIAG BRACE PARALLEL TO ROOF BEAMS. H H1 SCALE: TYPICAL DIAGONAL BRACE CONNECTION COMP MTL DECK/ CONC SLAB ON STL BEAMS G EXIST JOIST CHORD OR BEAM FLG ATTACH TO EXIST STL W/(3)-#12 SCREWS EXIST MTL DECK OR COMP CONC SLAB (6)-#12 SCREWS AT EACH ATTACHMENT ATTACH TO EXIST STL W/(3)-#12 SCREWS EXIST MTL DECK OR COMP CONC SLAB DIAG BRACE LAYOUT: A-504 P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\A-504_06078.dwg EXIST BAR JOISTS OR STEEL BEAMS @ 6'-0" O.C. MAX DIAGONAL PERPENDICULAR TO EXIST BAR JOISTS OR STEEL BEAMS EXIST BAR JOISTS OR STEEL BEAMS @ 6'-0" O.C. MAX PLOTTED: 7/16/2015 - 4:03 PM CONTINUOUS DIAG BRACE E USER: JGRAY AT DIAG BRACE EXIST JOIST CHORD OR BEAM FLG LA PLAZA MALL F #12 SCREWS (TYP) (2) 2x2x0'-3", 12 GA FRAMING CLIPS D #12 SCREWS, TYP SEE VIEW B-B FOR CONNECTION DIAGONAL BRACING DIAGONAL BRACING DIAGONAL PARALLEL TO EXIST BAR JOISTS OR STEEL BEAMS C EXISTING JOIST SUNGLASS HUT LA PLAZA MALL CONTINUOUS SEE VIEW B-B FOR CONNECTION 6", 16 GA MTL STUD WITH 6", 16 GA DEEP LEG TRACK. B 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 #12 SCREWS @ 6" O.C. MAX AND 2" FROM EACH END DRAWN BY: ALW REVIEWED BY: MLH/JMA 2 x 2 x 12 GA x 6" LG FRAMING CLIP, ONE SIDE OF DIAG, W/(3)-#12 SCREWS EACH LEG. AUTHORIZED FOR: FRAMING DETAILS A A1 SCALE: A-504 TYPICAL DIAGONAL BRACING CONNECTION ATTACHMENT TO EXISTING BAR JOIST OR STEEL BEAM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 K B. 1. 3. 4. 5. 6. 7. 8. H 9. 10. C. G D. F E. 4 1. DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE COMPLIMENTARY. SPECIFIC INFORMATION MAY BE FOUND IN EITHER OR BOTH. 2. THE TERM 'OWNER' AS STATED IN THE FOLLOWING SPECIFICATIONS AND CONSTRUCTION DOCUMENTS, REFERS TO THE TENANT OF THIS SPACE ONLY AND DOES NOT REFER TO THE LANDLORD OF THE PREMISES. 3. APPROVED VARIANCES TO THE PLANS AND SPECIFICATIONS ON ONE PROJECT SHALL NOT CONSTITUTE AN APPROVAL OF LIKE VARIANCES ON SUBSEQUENT PROJECTS. 2. J 3 5 B. C. D. E. THE CONTRACTOR SHALL FURNISH FULL TIME CONTINUOUS SUPERVISION. THE PROJECT SUPERINTENDENT SHALL REMAIN ON SITE THROUGH THE MERCHANDISE DATE OR THE COMPLETION OF THE PUNCHLIST WHICHEVER IS LAST TO OCCUR. SUSPENSION OF ALL CEILING AND OVERHEAD FRAMING IS TO BE FROM STRUCTURAL MALL BEAMS AND TOP CHORD OF TRUSSES ONLY, NOT FROM MALL DECK. GENERAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF IN-WALL BLOCKING FOR ALL ITEMS IN STORE. REVIEW DRAWINGS THOROUGHLY. ALL OWNER-FURNISHED MATERIALS ARE FURNISHED TAILGATE DELIVERY ONLY. THE CONTRACTOR IS RESPONSIBLE TO UNLOAD, EXAMINE, AND TRANSPORT MATERIALS FROM THE POINT OF OFF-LOAD TO THE JOBSITE OR STORAGE AREA AS APPLICABLE. MATERIALS WILL BE DELIVERED TO THE CLOSEST AVAILABLE TRUCK DOCK OR OTHER LOCATION AS DIRECTED BY THE LANDLORD. THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE, LOSS, THEFT, OR DESTRUCTION OF ALL OWNER-FURNISHED MATERIALS. THE CONTRACTOR WILL BE BACK-CHARGED THE FULL COST OF REPLACEMENT MATERIALS INCLUDING FREIGHT CHARGES. THE GENERAL CONTRACTOR SHALL EMPLOY SUBCONTRACTORS WHO ARE EXPERIENCED AND WHO EMPLOY EXPERIENCED TRADESMEN. THE GENERAL CONTRACTOR SHALL NOT EMPLOY NOISY CONSTRUCTION TECHNIQUES OR EQUIPMENT DURING MALL OR STORE HOURS. THE CONTRACTORS SHALL WORK IN COOPERATION AND HARMONY WITH THE LANDLORD AND THE ADJACENT TENANTS IN SCHEDULING WORK IN ORDER TO CAUSE THE LEAST INCONVENIENCE TO PERSONNEL AND PROPERTY. IF SECURITY IS REQUIRED WHILE WORKING IN ADJACENT TENANTS SPACE, THIS COST WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL NOT UTILIZE GAS-OPERATED EQUIPMENT IN OCCUPIED SHOPPING CENTERS. THE CONTRACTOR SHALL WORK IN HARMONY WITH THE LANDLORD'S REQUIREMENTS RELATING TO NOISE ABATEMENT AND SAFETY. THE CONTRACTOR SHALL FURNISH DUMPSTERS AS REQUIRED FOR THE EXCLUSIVE USE BY STORE PERSONNEL DURING MERCHANDISING. THE CONTRACTOR SHALL INCLUDE IN THE BID A MINIMUM OF ONE 40-YARD DUMPSTER OR THE EQUIVALENT. IF THE SALES AREA EXCEEDS 8,000 SQUARE FEET, THE CONTRACTOR SHALL INCLUDE ONE ADDITIONAL DUMPSTER. F. 1. EXERCISE PROPER PRECAUTION TO VERIFY ALL EXISTING CONDITIONS AND LAYOUT OF WORK. CONTRACTOR TO NOTIFY OWNER'S CONSTRUCTION MANAGER OF ANY DISCREPANCIES IMMEDIATELY. CONTRACTOR IS RESPONSIBLE FOR ANY ERROR RESULTING FROM FAILURE TO EXERCISE SUCH PRECAUTION. SUCH ERROR WILL NOT BE CONSIDERED SUBSEQUENTLY AS A BASIS FOR EXTRA COMPENSATION. 2. SHOULD A CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS, OR SHOULD HE BE IN DOUBT AS TO THEIR MEANING, HE SHALL AT ONCE NOTIFY THE OWNER'S CONSTRUCTION MANAGER. 3. GENERAL CONTRACTOR IS RESPONSIBLE FOR SUPPLYING OR RENTING ALL TOOLS, WELDERS, GENERATORS, ETC. FOR COMPLETING PROJECT. 1. ALL WORK, MATERIALS AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH ALL ORDINANCES, STATE AND LOCAL BUILDING CODES, LATEST EDITION, AND FOLLOW APPLICABLE LANDLORD REQUIREMENTS. 2. DESIGN LOADS: LOADS AND CODE RESTRICTIONS FOR ALL DESIGN CONSIDERATIONS SHALL CONFORM TO THE LOCAL AND STATE CODES, AND ALL GOVERNING CODES. 1. F. THE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A201 "GENERAL CONDITIONS OF THE CONTRACTOR FOR CONSTRUCTION" IS A PART OF THE CONTRACT DOCUMENTS. 6 SHALL BE FOUR INCH THICK CONCRETE SLAB REINFORCED WITH 6"x 6"W.W.F.; CONCRETE TO BE 3,500 PSI OR HIGHER PLACED OVER COMPACTED SAND AGGREGATE BASE. PLACE 10 MIL VAPOR BARRIER AT THE MIDPOINT OF THE COMPACTED SAND/AGGREGATE BASE. THE SOIL SHALL BE INSECT TREATED IF CUSTOMARY TO THE LOCALITY OR AS REQUIRED BY LANDLORD. PROVIDE JOINT SEALANT IN ALL CONCRETE CONTROL JOINTS AS SPECIFIED IN DIVISION 7. PROVIDE JOINT FILLER STRIPS WHERE APPLICABLE: ASTM D-1751, CELLULOSE FIBER. VAPOR RETARDER, CLEAR 10 MIL POLYETHELENE SHEET. SLAB FINISHES 1. FLOAT FINISH FOR INTERIOR STEPS, RAMPS AND SURFACES TO RECEIVE WATER PROOFING OR OTHER DIRECT-APPLIED MATERIAL 2. TROWELED FINISH FOR FLOOR SURFACES AND FLOORS TO RECEIVE FLOOR COVERINGS, PAINT OR OTHER THIN FILM FINISH COATINGS. 3. TROWEL AND FINE BROOM FINISH FOR SURFACES TO RECEIVE THINSET TILE. 4. NON-SLIP BROOM FINISH FOR EXTERIOR CONCRETE PLATFORMS, STEPS AND RAMPS. ANHYDROUS CALCIUM CHLORIDE CONCRETE MOISTURE VAPOR EMISSION TEST KIT CONDUCTING THE MOISTURE TEST 1. : BEFORE YOU TEST, MAKE SURE YOU HAVE BASIC TOOLS FOR CLEANING THE SLAB, INCLUDING A SCRAPER AND WIRE BRUSH. MAKE SURE YOU HAVE A QUALITY GRAM SCALE AND A PROPER SUPPLY OF TEST KITS AND PROTECTIVE CONES. ENSURE BUILDING CLIMATE IS BETWEEN 65 & 85 DEGREES FAHRENHEIT WITH RELATIVE HUMIDITY % BETWEEN 40-60 FOR AT LEAST 48 HOURS PRIOR TO, AND DURING TESTING. 2. : THE SLAB MUST BE CLEAN OF DEBRIS AND ADHESIVE RESIDUE. SHOT BLAST SURFACE OR WIRE BRUSH SLAB CLEAN. REMOVE DUST THOROUGHLY. DO NOT USE CHEMICALS OF ANY KIND TO CLEAN THE FLOOR. AVOID TEST LOCATIONS NEAR CRACKS OR JOINTS, OR IN DIRECT SUNLIGHT. PREPARE 3 TEST SITES FOR THE FIRST 1,000 SQ. FT. AND INCLUDE 1 MORE TEST FOR EACH ADDITIONAL 1,000 SQUARE FEET OF AREA. 3. : READ THE WARNING LABEL ON PACKAGE AND THEN OPEN THE CONTAINER BAG. SET THE ENTIRE TAPE SEALED DISH ON THE GRAM SCALE AND RECORD ITS WEIGHT ON THE DISH LID AND ON THE TEST KIT BOOKLET. RECORD THE STARTING DATE AND TIME AS WELL. ENSURE THAT THE SAME SCALE WILL BE AVAILABLE FOR RE-WEIGHING THE DISH, OR THE VALIDITY OF THIS TEST WILL BE COMPROMISED. 4. : REMOVE THE BLUE VINYL TAPE FROM THE DISH. BE CAREFUL NOT TO LOSE THE TAPE AS YOU WILL NEED TO RESEAL THE DISH LATER. STORE THE DISH LID CAREFULLY AND STICK THE TAPE ALONG THE SIDE OF THE PLASTIC. DOME TO KEEP IT SAFE. SOME PEOPLE PREFER TO TAPE THE DISH'S LID TO THE INSIDE OF THE DOME WHERE IT CAN BE READ THROUGH THE TOP. DO NOT TOUCH OR SPILL THE CALCIUM CHLORIDE. 5. : PLACE THE OPEN DISH ON THE SLAB MAKING SURE THE CALCIUM CHLORIDE INSIDE IS FAIRLY LEVEL. DO NOT SET THE KIT DIRECTLY OVER A CONTROL JOINT OR CRACK. REMOVE THE WHITE PAPER ON THE DOME, AND CENTER THE DOME OVER THE DISH. THE ONLY MOISTURE ABSORBED BY THE CALCIUM CHLORIDE MUST BE WITHIN THE 70 SQUARE INCH AREA OF THE DOME THAT IS IN CONTACT WITH THE CONCRETE SLAB. 6. : USING THE HANDLE OF YOUR WIRE BRUSH OR OTHER TOOL, FIRMLY SQUASH THE GASKET UNDER THE FLANGES OF THE DOME. THE IDEAL INSTALLATION WILL SEAT THE OUTER FLANGE OF THE DOME TO THE SLAB. THEN THE GASKET MATERIAL WILL MOVE TO LINE UP WITH THE INSIDE EDGE OF THE DOME. PLACE YOUR HAND OVER THE DOME AND GENTLY APPLY PRESSURE. THERE SHOULD BE NO LEAKS IN THE GASKET. 7. : PLACE THE OPTIONAL SAFETY CONE OVER THE DOME AND LET THE TEST REMAIN UNDISTURBED FOR 60 TO 72 HOURS. MOST MANUFACTURERS OF FLOORING PRODUCTS RECOMMEND AT LEAST ONE KIT PER 1,000 SQUARE FEET. THE TEST ONLY MEASURES A SMALL AREA OF SLAB SURFACE AND MOISTURE LEVELS CAN VARY GREATLY OVER 1,000 SQ. FT. TEST SEVERAL AREAS WHENEVER POSSIBLE. 8. : AFTER 60 TO 72 HOURS, CUT OPEN THE DOME AND CAREFULLY RETRIEVE THE DISH. REPLACE THE LID AND SEAL IT BACK UP WITH THE BLUE TAPE. WEIGH THE DISH AGAIN ON THE SAME GRAM SCALE. RECORD THE ENDING WEIGHT, DATE, AND TIME ON THE DISH LID AS WELL AS ON THE TEST KIT BOOKLET. FOLLOW THE INSTRUCTIONS IN THIS BOOKLET TO COMPUTE THE MOISTURE VAPOR EMISSION RATE. CALCULATING RESULTS: USE THE FOLLOWING EQUATION TO DETERMINE THE VAPOR EMISSION VOLUME IN POUNDS PER 1,000 SQUARE FEET IN 24 HOURS. SEE FOOTNOTE. EQUATION TO DETERMINE VAPOR EMISSION IN POUNDS: E 1. 2. 3. 4. USER: JGRAY PLOTTED: 7/16/2015 - 4:03 PM P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\A-701_06078.dwg LAYOUT: A-701 5. D 6. C 7. 8. 9. 10. 11. B 12. 13. WEIGHT GAIN X 118.932 = WITHIN FIVE (5) DAYS OF COMMENCEMENT OF CONSTRUCTION, OR WITHIN TWO (2) DAYS FOLLOWING COMPLETION OF DEMOLITION, THE CONTRACTOR SHALL CAREFULLY EXAMINE THE SITE AND REPORT TO THE OWNER'S CONSTRUCTION MANAGER ANY DISCREPANCIES IN THE LEASE-HOLD DIMENSIONS OR CONFLICTS BETWEEN THE PHYSICAL SPACE AND THE INTENT OF THE WORKING DRAWINGS (G.C. TO PAY SPECIAL ATTENTION TO POP-UP CEILING AREAS, CEILING HEIGHTS, AND AVAILABLE HEIGHT FOR ROLL-UP ENTRANCE GRILLES). GENERAL CONTRACTOR IS TO CONTACT LANDLORD'S ON-SITE MANAGER PRIOR TO ANY DEMOLITION WORK TO DETERMINE THE AVAILABILITY OF DUMPSTER PLACEMENT, NOISE AND DUST ABATEMENT REQUIREMENTS, ETC. GENERAL CONTRACTOR IS TO ARRANGE WITH THE LANDLORD A CONVENIENT TIME TO PERFORM DEMOLITION WORK AND INSTALL TEMPORARY PROTECTED MEANS OF EGRESS FROM REQUIRED EXITS, INCLUDING TEMPORARY LIGHTING AND SAFETY DEVICES, ALL IN ACCORDANCE WITH GOVERNING STATE AND LOCAL CODE AND LANDLORD REQUIREMENTS. GENERAL CONTRACTOR TO ERECT BARRICADE AT STOREFRONT PER LANDLORD'S SPECIFICATIONS. GENERAL CONTRACTOR TO INSTALL OWNER SUPPLIED BARRICADE SIGN (IF PROVIDED) AS SHOWN ON INSTRUCTIONS SENT WITH BID PACKAGES. THE GENERAL CONTRACTOR SHALL REMOVE, REPAIR, RESTORE AND REPLACE WHERE NECESSARY OR INDICATED ON THE DRAWINGS OR AS REQUIRED. CUT ALL NECESSARY OPENINGS FOR ANY REQUIRED PURPOSE AND REPAIR, WHERE NECESSARY, AFTER CUTTING. INSOFAR AS POSSIBLE, ALL PROTRUSIONS, MARKS, CRACKS OR OTHER EVIDENCE OF A DEFICIENT OR DAMAGED CONDITION SHALL BE ELIMINATED UNLESS SPECIFICALLY NOTED OTHERWISE. ANY PARTS WHICH ARE SPLIT, CRACKED, CHIPPED, SPALLED, BROKEN, MISSING, OR OUT OF LINE OR ADJUSTMENT, MECHANICALLY OR STRUCTURALLY UNSAFE OR UNSOUND, BENT, TORN, OR OTHERWISE DEFICIENT OR INJURED IN ANY MANNER, SHALL BE REMOVED, REPLACED, RESTORED, OR SATISFACTORILY REPAIRED AS DIRECTED BY THE OWNER'S CONSTRUCTION MANAGER. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL LEASE-HOLD IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO: INTERIOR WALLS, CEILINGS, FLOOR COVERINGS (ALL ADHESIVES), PLATFORMS, STORE-FRONTS, ETC. (UNLESS INDICATED OTHERWISE ON ARCHITECTURAL DRAWINGS). ALL EXISTING UNUSED MECHANICAL, ELECTRICAL AND/OR PLUMBING FIXTURES AND EQUIPMENT, INCLUDING ABANDONED ROOFTOP HVAC EQUIPMENT AND CURBS (UNLESS INDICATED OTHERWISE ON MECHANICAL AND ELECTRICAL DRAWINGS) AND/OR SKYLIGHTS ARE TO BE REMOVED AND THE ROOF PATCHED PER ITEM #12 BELOW: CAPPING IS PERMITTED! GENERAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL LOOSE ITEMS SUCH AS, BUT NOT LIMITED TO: TRADE FIXTURES, MISCELLANEOUS DECORATIONS, KITCHEN EQUIPMENT, ETC. ALL ABANDONED ELECTRICAL/TELEPHONE CONDUIT, PLUMBING LINES AND MECHANICAL DUCTWORK MUST BE REMOVED TO THE POINT OF ORIGIN. INFORM THE LANDLORD'S ON-SITE MANAGER OF ANY UTILITY NEEDING TO BE DISCONNECTED OR CAPPED, PRIOR TO DOING SO. GENERAL CONTRACTOR IS TO EXERCISE EXTREME CARE DURING DEMOLITION SO AS NOT TO DAMAGE OR DISRUPT UTILITIES OR SPRINKLER LINES WHICH MIGHT PASS THROUGH THIS SPACE TO SERVICE OTHER MALL SPACES OR OTHER TENANTS (G.C. WILL BEAR SOLE RESPONSIBILITY FOR ANY SUCH DAMAGE OR DISRUPTION). GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK AND MUST INFORM OWNER'S CONSTRUCTION MANAGER OF THE EXTENT OF SUCH WORK, PRIOR TO BIDDING. GENERAL CONTRACTOR IS TO DETERMINE HIS RESPONSIBILITY FOR THE FLOOR SLAB AND DEMISING WALL INSTALLATION OR MODIFICATIONS WITH LANDLORD AND OWNER'S CONSTRUCTION MANAGER TO MEET ALL TENANT IMPROVEMENT CRITERIA AND RESPONSIBILITY SET BY THE LANDLORD OR OWNER. GENERAL CONTRACTOR IS TO VERIFY THE ACTUAL CONDITION OF THE PERIMETER DEMISING WALLS AND/OR FLOOR SLAB PRIOR TO BIDDING. BID IS TO INCLUDE ALL WORK REQUIRED. a. b. c. d. THE VAPRECISION ANHYDROUS CALCIUM CHLORIDE TEST KIT, INSTRUCTIONS, CALCULATIONS AND ALL OTHER PRINTED INFORMATION ARE PROPERTY OF VAPRECISION TESTING SYSTEMS, COPYRIGHT 1994. REVISED AUGUST 1999. THE VAPRECISION ANHYDROUS CALCIUM CHLORIDE TEST KIT CONFORMS TO THE AMERICAN SOCIETY FOR TESTING & MATERIALS DOCUMENTATION ASTM E-1907-97 AND ASTM-F_1869-98 AND IS ACTUALLY PICTURED IN THE ASTM E-1907 SPECIFICATION. ASTM DOCUMENTS ARE THE COPYRIGHT PROPERTY OF ASTM, AND CAN BE PURCHASED EASILY FROM THEIR WEB SITE AT WWW.ASTM.ORG. : THE FORMULA ABOVE COMPLIES TO ASTM DOCUMENTATION AS OF 8/99 AND DEDUCTS THE AREA OF THE CALCIUM CHLORIDE DISH IN CONTACT WITH THE SLAB. THERE IS A DEBATE REGARDING THIS ISSUE. TO CALCULATE THE TEST RESULT WITHOUT DEDUCTING THE AREA OF THE DISH, USE 108.846 INSTEAD OF 118.932. A. THE CONTRACTOR SHALL ACCOMPLISH ANY MISCELLANEOUS MASONRY WORK INDICATED ON THE PLANS, OR NOT INDICATED ON THE PLANS YET INCIDENTAL TO THE ACCOMPLISHMENT OF OTHER WORK. WHERE APPLICABLE, MASONRY WORK SHALL MATCH EXISTING WORK. FINISH BRICK WORK SHALL BE NEATLY TOOTHED INTO EXISTING MASONRY IF APPLICABLE. A. STRUCTURAL STEEL: REFER TO STRUCTURAL DRAWINGS (WHERE APPLICABLE.) B. METAL STUDS: COLD-FORMED GALVANIZED STEEL STUDS SIZED AS INDICATED ON DRAWINGS, WHICH CONFORM TO ASTM C955 & C1007 . INCLUDE ALL ACCESSORIES, SUCH AS BRIDGING, TRACK, ETC. PROVIDE ALL MISCELLANEOUS BOLTS, CLIPS, ANCHORS, ANGLES, BRACKETS, SLEEVES, FASTENERS, AND OTHER METAL ITEMS AS REQUIRED. WOOD STUDS MAY BE SUBSTITUTED WHERE PERMISSIBLE BY CODES. 1. COLD FORMED STEEL FRAMING SHALL CONFORM TO REQUIREMENTS OF THE LATEST EDITION OF ANSI "SPECIFICATION FOR DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" 2. STUDS SHALL BE INSTALLED SO THE ENDS ARE POSITIONED AGAINST THE INSIDE OF THE RUNNER TRACK WEB PRIOR TO FASTENING AND SHALL BE ATTACHED TO BOTH FLANGES OF THE UPPER AND LOWER RUNNER TRACKS. 3. FOR VERTICAL STUDS WHERE THERE IS NO SHEATHING ATTACHED (SUCH AS ABOVE THE CEILING,) OR WHERE SHEATHING IS ATTACHED TO ONLY ONE FACE, PROVIDE STANDARD BRIDGING AT 48" O.C. MAX. ATTACH PER MANUFACTURER'S SPECIFICATIONS. C. DECORATIVE METALS: INSTALL OWNER PROVIDED DECORATIVE METAL SUCH AS STAINLESS STEEL, PREFINISHED METAL, ETC. AS INDICATED ON DRAWINGS, PER MANUFACTURER'S RECOMMENDATIONS. D. OWNER SUPPLIED METALS: G.C. IS RESPONSIBLE TO CONTACT VENDOR FOR ORDERING OF PREFINISHED METAL STOREFRONT PANELS, CORNER GUARDS AT TILE FACED COLUMNS. REFER TO INDIVIDUAL DETAILS FOR APPLICATION AND INSTRUCTIONS. E. MISCELLANEOUS METALS: PROVIDE METAL SHAPES AND FABRICATIONS AS REQUIRED AND NOT INCLUDED AS PART OF OTHER SECTIONS, WITH ANCHORS AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. SUBMIT SHOP DRAWINGS FOR CUSTOM DATA, PRODUCT DATA FOR MANUFACTURED ITEMS AND TEMPLATES FOR ANCHOR INSTALLATION BY OTHERS. STEEL SHAPES TO BE ASTM A36 STEEL. A. PROVIDE NEW LUMBER, BEARING GRADE AND TRADEMARK OF ASSOCIATION UNDER WHICH IT WAS PRODUCED. B. LAYOUT, CUT, FIT AND ERECT FRAMING FOR ROUGH AND FINISHED WORK. INSTALL BLOCKING, NAILERS, FURRING AND OTHER ROUGH AND FINISHED MATERIALS AS REQUIRED. BRACE, PLUMB LEVEL MEMBERS IN TRUE ALIGNMENT AND RIGIDLY SECURE IN PLACE WITH SUFFICIENT NAILS, SCREWS AND BOLTS AS NECESSARY. C. USE FIRE RETARDANT LUMBER AND TRIM WHERE REQUIRED BY STATE OR LOCAL CODES, WHICH BEAR THE MANUFACTURER'S STAMP OF AUTHENTICITY. D. FURNISH AND INSTALL ALL GROUNDS OR BLOCKING REQUIRED TO RECEIVE STORE FIXTURES OR OTHER WALL HUNG ELEMENTS, IF SHOWN ON DRAWINGS. E. FURNISH AND INSTALL ALL ROUGH HARDWARE, ANCHORS, BOLTS, ETC., AS REQUIRED FOR CARPENTRY WORK. F. FINISH CARPENTRY: CONFORM TO ARCHITECTURAL WOODWORK INSTITUTE (AWI) QUALITY STANDARDS OR WOODWORK INSTITUTE OF CALIFORNIA (WIC) "MANUAL OF MILLWORK" STANDARDS. PROVIDE PRIMED WOOD WALL BASE - COPE ALL CORNERS, MITER ALL OUTSIDE CORNERS, COUNTER SINK AND PUTTY ALL NAIL HOLES AND SAND SMOOTH. A. THE CONTRACTOR IS RESPONSIBLE TO DETERMINE IF A NEW CONCRETE SLAB IS REQUIRED IN ALL OR PART OF THE LEASED SPACE. SUCH FLOOR SLAB SHALL BE INSTALLED IN ACCORDANCE WITH ALL REQUIREMENTS, LOCAL CODES, OR COMMON STANDARDS OF PRACTICE TO THE LOCALITY OF THE PROJECT OR WHICHEVER IS STRICTER. IN THE ABSENCE OF THE ABOVE, THE CONTRACTOR SHALL CONTACT THE OWNER FOR DIRECTION. MINIMUM REQUIREMENTS FOR THE FLOOR SLABS ON GRADE 1 2 3 POUNDS PER 1,000 SQUARE FEET IN 24 HOURS POUNDS PER 1,000 SQUARE FEET IN 24 HOURS A 4 5 9 10 11 12 6 7 13 14 (3) E. F. C. D. 1. 1. : GENERAL CONTRACTOR TO CONTACT LANDLORD'S ON-SITE MANAGER FOR SPECIFICATIONS ON ROOF PATCHING OR NAME OF ROOFING CONTRACTOR TO CONTACT FOR REPAIRS. : GENERAL CONTRACTOR TO PROVIDE AND INSTALL RIGID AND/OR FULL BATT INSULATION AND 4 MIL POLYETHELENE (VISQUEEN) VAPOR RETARDER AT WALLS AND CEILING AS REQUIRED BY LANDLORD AND CONSTRUCTION DRAWINGS. 1. GENERAL: PROVIDE EXTERIOR AND INTERIOR JOINT SEALERS NOT PROVIDED ELSEWHERE; TYPE SUITABLE FOR APPLICATION INDICATED WITH ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. 2. INSTALLER QUALIFICATIONS: FIRM WITH MINIMUM FIVE YEAR'S SUCCESSFUL EXPERIENCE ON PROJECTS OF SIMILAR TYPE AND SIZE, USING SPECIFIED PRODUCTS. 3. WARRANTY: REPAIR OR REPLACE JOINT SEALERS WHICH FAIL TO PERFORM AS INTENDED, BECAUSE OF LEAKING, CRUMBLING, HARDENING, SHRINKAGE, BLEEDING, SAGGING, STAINING OR LOSS OF ADHESION; WARRANTY PERIOD TWO YEARS. 4. EXTERIOR NON-TRAFFIC JOINTS: GE/SILPRUF, DOW/790-795 OR PECORA/854, LOW MODULES SILICONE SEALANT. 5. TRAFFIC BEARING JOINTS: MAMECO/VULKEM 245 OR PECORA/NR-200 UREXPAN, MULTI-COMPONENT POLYURETHANE, SELF-LEVELING JOINT SEALER. 6. MILDEW-RESISTANT SANITARY SEALANTS: GE/SANITARY SEALANT, DOW/BATHTUB CAULK, OR PECORA/863 #345 WHITE; PROVIDE AT INTERIOR AREAS WHERE SEALANT WILL BE EXPOSED TO WATER. 7. GENERAL INTERIOR JOINT SEALER: PECORA/AC-20 OR SONNEBORN/SONOLAC, ACRYLIC OR LATEX EMULSION. MISCELLANEOUS MATERIALS: PRIMERS, SEALERS, JOINT CLEANERS, BOND BREAKER TAPE 8. AND SEALANT BACKER RODS AS RECOMMENDED BY SEALANT MANUFACTURER FOR APPLICATIONS INDICATED. a. OVERSIZE BACKER ROD MINIMUM 30 % TO 50 %%% OF JOINT OPENING. 9. COLORS: AS INDICATED OR SELECTED BY OWNER'S PROJECT MANAGER FROM MANUFACTURER'S FULL RANGE OF COLORS. 10. PREPARATION: CLEAN JOINT SURFACES IMMEDIATELY BEFORE INSTALLATION OF JOINT SEALER AND PRIME OR SEAL JOINT SURFACES AS RECOMMENDED BY MANUFACTURER. 11. INSTALLATION: COMPLY WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND ASTM C1193. b. EMPLOY INSTALLATION TECHNIQUES WHICH WILL ENSURE JOINT SEALERS ARE DEPOSITED IN UNIFORM, CONTINUOUS RIBBONS WITHOUT GAPS OR AIR POCKETS, WITH COMPLETE "WETTING" OF BOND SURFACES. 1. 2. E. EDGE SEALING: IMMEDIATELY AFTER CUTTING THE FINAL SIZES, AND APPLYING EDGE TREATMENT; FACTORY SEAL EDGES OF MIRRORS WITH EDGE SEALER TO PREVENT CHEMICAL OR ATMOSPHERIC PENETRATION OF GLASS COATING. 6. MISCELLANEOUS MATERIALS a. SETTING BLOCK: NON-RUBBER OR NON-NEOPRENE BASED ELASTOMERIC MATERIAL MANUFACTURED FOR SETTING SILVERED FLAT GLASS MIRRORS, COMPATIBLE WITH ADHESIVE USED FOR PLACEMENT, WITH A TYPE A SHORE DUROMETER HARDNESS OF 85, PLUS OR MINUS 5. 1/8" WIDE X 1/4" HIGH X 4" LONG. b. EDGE SEALER: COATING COMPATIBLE WITH GLASS COATING AND APPROVED BY MIRROR MANUFACTURER FOR USE IN PROTECTING AGAINST SILVER DETERIORATION AT MIRROR EDGES. c. MIRROR MASTIC: PALMER PRODUCTS CORP., "MIRROR-MASTIC", (502) 893-3668, (800) 431-6151, FAX (502) 895-9253. d. DRYWALL AND PLYWOOD PAINT (POROUS SUBSTRATE PRIMER): PALMER PRODUCTS CORP. "MIRROR-MASTIC BOND", (502) 893-3668, (800) 431-6151, FAX (502) 895-9253. e. NEW CONSTRUCTION - GENERAL CONTRACTOR TO FURNISH AND INSTALL 48" WIDE REFLECTIVE BUBBLE INSULATION MADE WITH TWO LAYER REFLECTIVE METALIZED ALUMINUM SEPARATED BY A 5/16" ENCLOSED AIR SPACE. INSTALL PER MANUFACTURERS SPECIFICATIONS. EXISTING CONSTRUCTION - GENERAL CONTRACTOR TO FURNISH AND INSTALL 24" WIDE .024 WHITE ALUMINUM TRIM COIL. INSTALL PER MANUFACTURERS SPECIFICATIONS. 7. WEATHER BARRIER MEMBRANE (DUPONT TYVEK COMMERCIALWRAP) MANUFACTURER: DUPONT; 4417 LANCASTER PIKE, CHESTNUT RUN PLAZA 728, WILMINGTON, DE 19805; 1-800-44-TYVEK (8-9835); INSTALLATION SHALL BE IN ACCORDANCE WITH WEATHER BARRIER MANUFACTURER'S INSTALLATION GUIDELINES AND RECOMMENDATIONS. SECURE USING WEATHER BARRIER MANUFACTURER RECOMMENDED FASTENERS, SPACE 12-18 INCHES VERTICALLY ON CENTER ALONG STUD LINE, AND 24 INCHES ON CENTER, MAXIMUM HORIZONTALLY. 8. : 1. DOOR HARDWARE: REFER TO DOOR SCHEDULE FOR HARDWARE SPECIFICATIONS. 2. HOLLOW METAL FRAMES: K.D. MINIMUM 16 GAUGE. SIZE AND SHAPE PER DOOR SCHEDULE. 3. LABELED DOORS: WHERE REQUIRED, PROVIDE U.L. LABEL DOORS AND FRAMES PER APPLICABLE STATE AND LOCAL BUILDING CODES. LABEL DOORS TO RECEIVE DOOR CLOSER. 4. FABRICATE AND ERECT TRUE, PLUMB AND SQUARE AS SPECIFIED AND AS DETAILED AND PER MANUFACTURER'S RECOMMENDATIONS. B. : 1. GLASS a. STOREFRONT GLASS TO BE HORIZONTALLY TEMPERED. SIZE AND NUMBER OF PIECES AS SHOWN ON DRAWINGS. GLAZING CONTRACTOR TO PROVIDE AND INSTALL ALL GLAZING CHANNELS, GASKETS, BLOCKING, ETC., REQUIRED FOR COMPLETE INSTALLATION. PROVIDE NEAT, UNIFORM (1/4" WIDE UNLESS NOTED OTHERWISE) GAPS BETWEEN GLASS PANES AND BETWEEN PANES AND ADJACENT VERTICAL SURFACES. b. ARRISSED EDGE: EDGES TO BE DIAMOND GROUND 1/16" 45 DEGREE BEVEL AT FRONT AND BACK FACES WITH ALL EXPOSED EDGES UNIFORMLY MACHINE POLISHED. c. OWNER REQUIRES THAT STOREFRONT GLASS NOT BOW MORE THAN +/- 1/16" OUT OF VERTICAL. d. ALL GLASS TO BE SET IN GLAZING GASKETS THE SIZE AND SHAPE NECESSARY TO ACCOMPLISH GOOD WORKMANSHIP. CAULKING NOT PERMITTED. C. : 1. QUALITY ASSURANCE a. INSTALLER QUALIFICATIONS: AN EXPERIENCED INSTALLER WHO HAS COMPLETED MIRROR GLAZING SIMILAR IN MATERIAL, DESIGN, AND EXTENT TO THAT INDICATED; WHOSE WORK HAS RESULTED IN MIRROR INSTALLATIONS WITH A RECORD OF NOT LESS THAN 5 YEARS OF SUCCESSFUL IN-SERVICE PERFORMANCE. b. SOURCE LIMITATIONS FOR MIRRORS: OBTAIN MIRRORS FROM ONE SUPPLIER/MANUFACTURER FOR EACH TYPE OF MIRROR INDICATED. c. SOURCE LIMITATIONS FOR GLAZING ACCESSORIES: OBTAIN GLAZING ACCESSORIES FROM ONE SOURCE FOR EACH TYPE OF ACCESSORY INDICATED. d. GLAZING PUBLICATIONS: COMPLY WITH THE APPLICABLE RECOMMENDATIONS OF THE FOLLOWING. WHERE RECOMMENDATIONS CONFLICT THE MORE STRINGENT SHALL APPLY. e. GLASS ASSOCIATION OF NORTH AMERICA (GANA): "GLAZING MANUAL" AND THE MIRROR DIVISION'S "MIRRORS, HANDLE WITH EXTREME CARE: TIPS FOR THE PROFESSIONAL ON THE CARE AND HANDLING OF MIRRORS." f. NATIONAL GLASS ASSOCIATION (NGA): "CUSTOM MIRRORS, FABRICATION AND INSTALLATION. 2. DELIVERY, STORAGE, AND HANDLING. a. PROTECT MIRRORS ACCORDING TO MIRROR MANUFACTURER'S WRITTEN INSTRUCTIONS AND AS NEEDED TO PREVENT DAMAGE TO MIRRORS FROM CONDENSATION, TEMPERATURE CHANGES DIRECT EXPOSURE TO SUN, OR OTHER CAUSES. b. COMPLY WITH MIRROR MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SHIPPING, STORING, AND HANDLING MIRRORS AS NEEDED TO PREVENT DETERIORATION OF SILVERING, DAMAGE TO EDGES, AND ABRASION OF GLASS SURFACES AND APPLIED COATINGS. STORE INDOORS, PROTECTED FROM MOISTURE INCLUDING CONDENSATION. 3. PROJECTION CONDITIONS: ENVIRONMENTAL LIMITATIONS - DO NOT INSTALL MIRRORED GLASS UNTIL AMBIENT TEMPERATURE AND HUMIDITY CONDITIONS ARE MAINTAINED AT LEVELS INDICATED FOR FINAL OCCUPANCY. 4. SILVERED FLAT GLASS MIRROR MATERIAL: 6.0 MM THICK AND COMPLYING WITH ASTM C 1503, MIRROR SELECT QUALITY FOR USE IN VISUALLY DEMANDING APPLICATIONS REQUIRING MINIMAL DISTORTIONS AND BLEMISHES. 5. FABRICATION a. CUTOUTS: FABRICATE CUTOUTS FOR NOTCHES AND HOLES IN MIRRORS WITHOUT MARRING VISIBLE SURFACES. LOCATE AND SIZE CUTOUTS SO THEY FIT CLOSELY AROUND PENETRATIONS IN MIRRORS. b. MIRROR EDGE TREATMENT: CUTTING AND POLISHING (1) TYPICAL MIRRORS: FLAT EDGES WHERE THE CLEAN CUT "SQUARE" EDGE OF THE GLASS IS FLAT AND SURFACES EDGES ARE SLIGHTLY ARRISSED. AFTER GRINDING THE ARISSES, EDGES SHALL BE POLISHED TO A HIGH GLOSS SURFACE WHERE THE SURFACE REFLECTIVITY IS SIMILAR IN APPEARANCE TO THE MAJOR SURFACE OF THE GLASS. (2) BEVELED EDGED MIRRORS: PROVIDE BEVELED EDGED MIRRORS WHERE THE SURFACE EDGE OF THE GLASS IS BEVELED TO WIDTH INDICATED ON THE OWNER FURNISHED DRAWINGS. THE ANGLE FORMED BY THE INTERSECTION OF THE PLANCE OF THE BEVEL WITH THE MAJOR SURFACE FACE OF THE GLASS SHALL BE BETWEEN 3 TO 10 DEGREES. THE BEVELED SURFACE AND THE NOSE OF THE BEVEL SHALL BE POLISHED TO A HIGH GLOSS SURFACE WHERE THE SURFACE REFLECTIVITY IS SIMILAR IN APPEARANCE TO THE MAJOR SURFACE OF THE GLASS. 8 9 10 TOP AND BOTTOM ALUMINUM J CHANNELS: ALUMINUM EXTRUSIONS WITH A RETURN DEEP ENOUGH TO PRODUCE A GLAZING CHANNEL TO ACCOMMODATE 6 MM THICK MIRRORS AND HEAVY BODIED MIRROR MASTIC SPECIFIED AND IN A SINGLE PIECE. THE ENDS OF THE BACK LIPS OF ALL CHANNELS SHALL BE FACTORY SNIPPED AND FILED SO THAT THEY WILL NOT BE SEEN AFTER INSTALLATION. (1) BOTTOM AND SIDE TRIM: C.R. LAURENCE CO. INC., 1/4" STANDARD "J" CHANNEL (CATALOG NUMBER D636P POLISHED FINISH), (800) 421-6144, FAX (800) 262-3299. J-CHANNELS FORMED WITH FRONT LEG AND BACK LEG NOT LESS THAN 3/8" AND 7/8" IN HEIGHT, RESPECTIVELY. D. 1. 2. 4. 5. TOP TRIM: C.R. LAURENCE CO. INC., 1/4" DEEP NOSE "J" CHANNEL (CATALOG NUMBER D645P POLISHED FINISH), (800) 421-6144, FAX (800) 262-3299. J-CHANNELS FORMED WITH FRONT LEG AND BACK LEG NOT LESS THAN 5/8" AND 1-3/16" IN HEIGHT, RESPECTIVELY. f. STUD FASTENERS: PROVIDE #6 GAGE DIAMETER, 1-5/8" LONG, PHILLIPS BUGLE HEAD, SELF-DRILLING TYPE, FINE THREADED STEEL SCREW FASTENERS IN QUANTITY AS REQUIRED FOR SUPPORT AND FASTENING OF WOOD TRIMS AND MIRRORS CHANNELS TO DRYWALL STUD FRAMING AND SHEET METAL BACKER PLATES. HILTI KWI-PRO SELF DRILL DRYWALL SCREWS, ORDERING NAME: 6" X 1'-5/8" PBH SD, ITEM #: 00086216; HILTI CORPORATION (800) 879-8000. g. PLASTIC WOOD FILLER: COMMERCIAL QUALITY WOOD FILLER SPECIFICALLY MANUFACTURED TO ADVANCE THE FINAL BUILD AND SMOOTHNESS OF THE INSTALLED WOOD TRIM SURFACE BY FILLING DENTS, SCRATCHES, MITER JOINTS, AND VOIDS ABOVE COUNTERSUNK FASTENER HEADS. THE SELECTED FILLER SHALL BE EITHER NEUTRAL OR TINTED TO MATCH THE COLOR OF THE WOOD TRIM. h. PLYWOOD FASTENERS: PROVIDE MINIMUM #6 GAGE DIAMETER, PHILLIPS FLAT HEAD, SHARP POINTED, COARSE THREADED, STEEL WOOD SCREW FASTENERS IN QUANTITY AS REQUIRED. FURNISH PLYWOOD FASTENERS IN LENGTH AS REQUIRED TO SPAN THROUGH WOOD MIRROR TRIM, AND MIRROR CHANNELS, PLUS 3/4" i. WOOD MIRROR TRIM EXAMINATION a. EXAMINE SUBSTRATES, OVER WHICH MIRRORS ARE TO BE MOUNTED, WITH INSTALLER PRESENT, FOR COMPLIANCE WITH INSTALLATION TOLERANCES, SUBSTRATE PREPARATION, AND OTHER CONDITIONS AFFECTING PERFORMANCE. (1) VERIFY COMPATIBILITY AND SUITABILITY OF SUBSTRATES, INCLUDING COMPATIBILITY OF MIRROR MASTIC WITH EXISTING FINISHES OR PRIMERS. PROCEED WITH MIRRORED GLASS INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED AND SURFACES ARE DRY. PREPARATION a. COMPLY WITH MASTIC MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS FOR PREPARATION OF SUBSTRATES. (1) MIRROR, DRYWALL AND PLYWOOD SUBSTRATES SHALL BE FREE OF DUST, BE CLEAN, AND DRY PRIOR TO APPLICATION OF MIRROR MASTIC AND DRYWALL AND PLYWOOD PAINT. IF PLYWOOD OR DRYWALL SURFACES HAVE BEEN PAINTED PRIOR TO APPLICATION OF THE SPECIFIED DRYWALL AND PLYWOOD PAINT THE EXISTING PAINT SHALL BE SANDED THROUGH THE ORIGINAL SURFACE AND THE SUBSTRATE CLEANED PRIOR TO THE APPLICATION OF DRYWALL AND PLYWOOD PAINT. : GENERAL: INSTALL MIRRORS WITH MIRROR GLAZING CHANNELS TO COMPLY WITH WRITTEN INSTRUCTION OF MIRROR AND MIRROR GLAZING CHANNEL MANUFACTURERS, WITH REFERENCED GANA AND NGA PUBLICATIONS, OWNER FURNISHED DRAWINGS, AND AS SPECIFIED. MOUNT MIRRORS PLUMB, IN LINE AND IN A MANNER THAT AVOIDS DISTORTING REFLECTED IMAGES MIRROR CHANNEL INSTALLATION: a. TO PLYWOOD: DRILL, DO NOT DIMPLE, BACK LIP OF CHANNEL TO RECEIVE FASTENERS WITH HOLES PROPERLY SIZED AND SPACED TO RECEIVE FASTENERS. ATTACH MIRROR CHANNELS BY SCREW ATTACHING MIRROR CHANNEL THROUGH THE BACK LIP OF THE CHANNEL TO PLYWOOD SUBSTRATE IN ACCORDANCE WITH THE FASTENER MANUFACTURERS WRITTEN INSTRUCTIONS. INSTALL THE WEB OF THE TOP CHANNEL 1/4" HIGHER THAN THE HEIGHT OF THE MIRROR TO ALLOW THE RAISING OF THE MIRROR IN TO THE TOP CHANNEL AND ITS SUBSEQUENT LOWERING INTO THE BOTTOM CHANNEL. AFTER INSTALLING FASTENERS PLACE MASKING TAPE OVER THE ENTIRE LENGTH OF THE BACK LIP OF THE CHANNEL COMPLETELY COVERING THE FASTENER HEADS TO PROTECT THE MIRROR FROM BEING CHIPPED IN SETTING. ADHERE SETTING BLOCKS AT QUARTER POINTS FOR BOTTOM MIRROR CHANNELS USING ONLY 2 SETTING BLOCKS PER MIRROR PANEL. b. TO DRYWALL: MARK THE LOCATIONS FOR THE STUD FASTENERS ON THE BACK LIP OF EACH MIRROR CHANNEL AT EQUAL INTERVALS NOT OVER 8" ON CENTER, AND NOT MORE THAN 3" FROM ENDS PRIOR TO DRILLING THE CHANNEL. DRILL AND COUNTERSINK, DO NOT DIMPLE BACK LIP OF CHANNEL TO RECEIVE STUD FASTENERS AT MARKED LOCATIONS WITH HOLES PROPERLY SIZED TO RECEIVE STUD FASTENERS. ATTACH MIRROR CHANNELS BY SCREW ATTACHING MIRROR CHANNEL THROUGH THE BACK LIP OF THE CHANNEL THROUGH DRYWALL, STUD FRAMING AND SHEET METAL BACKER PLATE SUBSTRATES IN ACCORDANCE WITH THE FASTENERS MANUFACTURERS WRITTEN INSTRUCTIONS. (1) INSTALL THE WEB OF THE TOP CHANNEL 1/4" HIGHER THAN THE HEIGHT OF THE MIRROR TO ALLOW THE RAISING OF THE MIRROR INTO THE TOP CHANNEL AND ITS SUBSEQUENT LOWERING ONTO THE WEB OF THE BOTTOM CHANNEL. AFTER INSTALLING FASTENERS PLACE MASKING TAPE OVER THE ENTIRE LENGTH OF THE BACK LIP OF THE CHANNEL COMPLETELY COVERING THE FASTENER HEADS TO PROTECT THE MIRROR FROM BEING CHIPPED IN SETTING. ADHERE SETTING BLOCKS TO THE WEB OF THE BOTTOM MIRROR CHANNELS, LOCATED AT QUARTER POINTS, USING 2 SETTING BLOCKS PER MIRROR PANEL. WOOD TRIM & INSTALLATION a. BEFORE INSTALLING MIRROR WOOD TRIM, EXAMINE SHOP-FABRICATED WORK FOR COMPLETION AND COMPLETE WORK AS REQUIRED. PRIME TO ALL EXPOSED SURFACES OF THE MIRROR WOOD TRIM WHICH WILL BE IN CONTACT WITH THE MIRROR BACKING TO ELIMINATE INTERACTIONS BETWEEN THE RESINS IN THE WOOD AND THE MIRROR BACKING. b. INSTALL MIRROR WOOD TRIM PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. SCRIBE AND CUT MIRROR WOOD TRIM TO FIT ADJOINING WORK, AND REFINSH CUT SURFACES AND REPAIR DAMAGED FINISH AT CUTS. INSTALL WITH MINIMUM NUMBER OF JOINTS POSSIBLE, USING FULL-LENGTH PIECES (FROM MAXIMUM LENGTH OF WOOD TRIM AVAILABLE) TO GREATEST EXTENT POSSIBLE. DO NOT USE PIECES LESS THAN 16" LONG, EXCEPT WHERE SHORTER SINGLE-LENGTH PIECES ARE NECESSARY. SCARF RUNNING JOINTS. MITERS OVER 4" LONG SHALL BE SPLINED AND GLUED. PROTECTION AND CLEANING a. PROTECT MIRRORS FROM BREAKAGE AND CONTAMINATING SUBSTANCES RESULTING FROM CONSTRUCTION OPERATIONS. USING CLEAN WARM WATER, CLEAN MIRRORS BY METHODS RECOMMENDED IN REFERENCED GLAZING STANDARDS. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150343 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL (2) A. 4.5 X 118.932 = 8.3 64.5 TOTAL HOURS OVERALL WIDTH (FACE OF GYPSUM BOARD ON DEMISING WALL TO FACE OF GYPSUM BOARD ON DEMISING WALL). OVERALL LENGTH (LEASE LINE TO INNER-FACE OF GYPSUM BOARD ON REAR WALL.) ANY AND ALL COLUMN LOCATIONS - FREE STANDING OR PROJECTING. AVAILABLE CLEAR HEIGHT FOR GRILLE AND CEILING AS DIMENSIONED ON DRAWINGS. 8 NUMERIC EXAMPLE W/ A 4.5 GAIN IN 64.5 HRS. (ALWAYS ROUND TO THE NEAREST TENTH): WEIGHT GAIN X 118.932 = POUNDS TOTAL HOURS A. 7 LA PLAZA MALL A. 2 AT 1 SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 DRAWN BY: ALW REVIEWED BY: MLH/JMA AUTHORIZED FOR: ARCHITECTURAL SPECIFICATIONS A-701 11 12 13 14 3 E. : 1. GENERAL: INSTALL OWNER SUPPLIED EXTRUDED ALUMINUM STOREFRONT AND ENTRANCE SYSTEM WITH DOORS, FRAMES, HARDWARE, AND ACCESSORIES AS REQUIRED FOR COMPLETE WEATHERTIGHT INSTALLATION. STANDARDS: COMPLY WITH ARCHITECTURAL ALUMINUM MANUFACTURERS ASSOCIATION (AAMA) "ALUMINUM STORE FRONT AND ENTRANCE MANUAL." CODES AND REGULATIONS: COMPLY WITH APPLICABLE CODES AND REGULATIONS. SUBMITTALS: NOT REQUIRED. INSTALLATION WARRANTY MANUFACTURER: OLD CASTLE OR EQUAL , AS APPROVED BY OWNER. STOREFRONT: EXTRUDED ALUMINUM ENTRANCE SYSTEM AS INDICATED ON DRAWINGS. a. ALUMINUM TYPE: AS RECOMMENDED BY MANUFACTURER FOR APPLICATION INDICATED, BUT NOT LESS THAN EXTRUDED ALUMINUM, ASTM B221, 6061 OR 6063 ALLOY AND T5 OR T6 TEMPER. FINISH: SEE DRAWINGS GLAZING: ASTM C1048, PROVIDE FULLY TEMPERED SELECT GLAZING QUALITY CLEAR FLOAT GLASS; NOMINAL 1/2" SAFETY GLASS UNLESS OTHERWISE INDICATED. a. APPLIED GLAZING FILM: SUPPLY & APPLY 3M FILM ON ALUMINUM FRAMED STOREFRONT GLASS WHERE INDICATED ON DRAWINGS. GLAZING ACCESSORIES: OF TYPE RECOMMENDED BY MANUFACTURER TO SUIT SECURITY LOCATIONS AND APPLICATIONS FOR DRY GLAZING INSTALLATION. MISCELLANEOUS MATERIALS: a. STEEL REINFORCEMENT AND BRACKETS: MANUFACTURER'S STANDARD WITH MINIMUM 2 OZ. HOT-DIP ZINC COATING, ASTM A123, APPLIED AFTER FABRICATION. b. BITUMINOUS PAINT: COLD-APPLIED MASTIC, SSPC PAINT 12, COMPOUNDED FOR 30 MIL THICKNESS PER COAT. c. FLASHING: INSTALL SUB-SILL FLASHING MEMBERS; MINIMUM 22 GAGE SHEET ALUMINUM OF SIZES AND SHAPES INDICATED AND AS REQUIRED TO DRAIN WATER TO EXTERIOR; MATCH ADJACENT ALUMINUM MEMBER FINISH. d. ANCHORING DEVICES: CORROSION RESISTANT TYPE CAPABLE OF SUPPORTING ENTRANCE SYSTEM AND SUPERIMPOSED DESIGN LOADS; DESIGN TO ALLOW ADJUSTMENTS OF SYSTEM PRIOR TO BEING PERMANENTLY FASTENED IN PLACE. FABRICATION: a. ACCURATELY FIT TOGETHER JOINTS AND CORNERS; MATCH COMPONENTS ENSURING CONTINUITY OF LINE AND DESIGN; ENSURE JOINTS AND CONNECTIONS ARE FLUSH, 1/64th INCH MAX. AND WEATHERPROOF. NO CAULK AT ANY JOINTS OR CONNECTIONS. NO EXCEPTIONS! b. SEPARATE DISSIMILAR MATERIALS WITH BITUMINOUS PAINT OR PREFORMED SEPARATORS WHICH WILL PREVENT CORROSION. INSTALLATION: INSTALL ALUMINUM FRAMED STOREFRONT ASSEMBLIES, INCLUDING ENTRANCES, IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND TO MEET DESIGN REQUIREMENTS INDICATED, FOR WEATHERTIGHT INSTALLATION. a. ENSURE ASSEMBLIES ARE PLUMB, LEVEL AND FREE OF WARP OR TWIST; MAINTAIN DIMENSIONAL TOLERANCES AND ALIGNMENT WITH ADJACENT WORK. b. USE SUFFICIENT ANCHORAGE DEVICES TO SECURELY AND RIGIDLY FASTEN ASSEMBLIES TO BUILDING. c. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, USING PROPER TEMPLATES. COORDINATE INSTALLATION OF CYLINDERS WITH SECTION 08700. d. INSTALL SILL MEMBERS AND THRESHOLDS IN BED OF COMPOUND, JOINT FILLERS OR GASKETS TO PROVIDE WEATHERTIGHT CONSTRUCTION. e. GLASS INSTALLATION: COMPLY WITH GANA GLAZING MANUAL AND GLAZING MANUFACTURER INSTRUCTIONS. DO NOT ALLOW GLASS TO TOUCH METAL SURFACES. 2. 3. 4. 5. 6. 7. 8. 9. J 10. 11. H 12. 13. G 4 E. 1. 2. LAYOUT: A-702 D 3. 4. USER: JGRAY PLOTTED: 7/16/2015 - 4:03 PM P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\A-701_06078.dwg 5. 6. 7. C B A : CERAMIC TILE AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. (IF APPLICABLE) INSTALL CERAMIC TILE USING RECOMMENDED METHODS OF THE TILE CONTRACTORS ASSOCIATION OF AMERICA AND THE TILE COUNCIL OF AMERICA, INC. INSTALL CERAMIC TILE USING GROUT AND JOINT SPACING SPECIFIED IN FINISH SCHEDULE. ADHESIVE IS TO BE PROVIDED AND INSTALLED BY GENERAL CONTRACTOR (PER MANUFACTURER'S SPECIFICATIONS). CAREFULLY CLEAN ALL WORK AND REPLACE OR REPOINT ANY DAMAGED WORK AND LEAVE IN PERFECT CONDITION. USE NO ACID, AGENT OR DEVICE THAT WILL MAR SURFACE. CONSULT WITH OWNER'S CONSTRUCTION MANAGER FOR INSTRUCTIONS (DO NOT POLISH CERAMIC TILE). CERAMIC TILES ARE TO BE SET WITHOUT TRIPPING HAZARD TO CUSTOMERS OR STAFF. THE GENERAL CONTRACTOR IS RESPONSIBLE TO CORRECT RAISED CERAMIC TILES FOR THE ENTIRE DURATION OF THE WARRANTY PERIOD AT THE DIRECTION OF THE OWNER'S CONSTRUCTION MANAGER. C. : 1. FURNISH AND INSTALL CEILING SYSTEM COMPLETE WITH SUSPENSION SYSTEM AND RELATED ACCESSORIES AS SHOWN ON DRAWINGS AND AS SPECIFIED. 2. SUSPENSION SYSTEMS SHALL BE ADEQUATE TO SUPPORT LIGHT FIXTURES, CEILING, GRILLES, DIFFUSERS AND OTHER NORMAL ACCESSORIES. PROVIDE SYSTEM COMPONENTS FROM A SINGLE MANUFACTURER. 3. INSTALL CEILING AND SUSPENSION SYSTEMS IN STRICT ACCORDANCE WITH ASTM C754, ASTM C635 AND ASTM C636. FINISH CEILING SHALL BE LEVEL, WITH JOINTS SNUG AND SQUARE, AND TILES OR PANELS IN PERFECT CONDITION. 4. MATERIALS AND FINISHES a. REFER TO DRAWINGS FOR LOCATION OF SPECIFIED MATERIALS AND FINISHES WHEN APPLICABLE. b. NON-SALES CEILING: AS SCHEDULED OR EQUAL. CLASS "A" RATING. c. WHEN A ONE-HOUR FIRE-RATED CEILING ASSEMBLY IS REQUIRED BY LANDLORD, STATE OR LOCAL CODES, THEN GENERAL CONTRACTOR IS TO CONFORM WITH UNDERWRITER'S LABORATORIES DESIGN FOR A ONE-HOUR RATED ASSEMBLY AS SCHEDULED. d. G.C. TO PROVIDE ONE BOX OF THE SPECIFIED CEILING TILES ON SITE FOR FUTURE USE. 5. SEISMIC ZONES: PROVIDE TO COMPLY WITH STATE AND LOCAL REQUIREMENTS FOR SEISMIC BRACING OF CEILING SUSPENSION SYSTEM, WITH ASTM E580 AND AS DETAILED ON DRAWINGS. COMPLY ALSO WITH AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE 7-02) AND CEILING AND INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION (CISCA) STANDARDS. CONSULT LOCAL CODES FOR MINIMUM CEILING AREA REQUIREMENTS. D. 1. 2. : GENERAL: G.C. TO INSTALL OWNER SUPPLIED VINYL FLOORING SYSTEM WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. PROJECT CONDITIONS: PRIOR TO INSTALLATION OF ANY FLOORING, GC MUST ENSURE THAT THE JOBSITE AND SUB-FLOOR MEET THE REQUIREMENTS OF THE FOLLOWING INSTRUCTION. a. G.C. TO PERFORM MOISTURE TEST ON ALL CONCRETE FLOORS AS DIRECTED BY NWFA AND INSTALL BOSTIK MVP4 VAPOR BARRIER. MOISTURE CONTENT OF WOOD SUB-FLOOR MUST NOT EXCEED 12% AND CONCRETE MOISTURE CONTENT MUST NOT EXCEED 3LBS. b. G.C. TO PROVIDE MOISTURE TEST REPORT TO CONSTRUCTION MANAGER 1 2 3 : SEE FINISH SCHEDULE. BUTT BASE TO FLOOR AND WALL WITH NO GAPS. FILL ALL CRACKS, JOINTS, ETC. IN SUB-FLOOR WITH CRACK FILLER APPROVED BY FLOORING MANUFACTURER. INSTALL ALL MATERIALS WITH WATERPROOF TYPE ADHESIVES AS RECOMMENDED BY FLOORING MANUFACTURER FOR MATERIALS AND SURFACES INVOLVED. THIS SPECIFICATION DEFINES THE REQUIREMENTS FOR SURFACE PREPARATION, COATING SYSTEMS, MINIMUM AND MAXIMUM DRY FILM THICKNESS, SPECIAL APPLICATION INSTRUCTIONS WHEN NECESSARY AND INSPECTION FOR PAINTING OF SPECIFIED SUBSTRATES. 2. IF INSTRUCTIONS CONTAINED IN THIS SPECIFICATION, BID DOCUMENTS OR THE PAINTING SCHEDULE ARE AT VARIANCE WITH THE PAINT MANUFACTURER'S INSTRUCTIONS OR THE APPLICABLE STANDARDS AND CODES PUBLISHED BY SSPC OF OSHA, SURFACES SHALL BE PREPARED AND PAINT APPLIED TO MEET THE HIGHER STANDARD, AS DETERMINED BY THE DESIGN AUTHORITY. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REQUESTING PROMPT CLARIFICATION WHEN INSTRUCTIONS ARE LACKING, CONFLICTS OCCUR IN THE SPECIFICATION AND/OR PAINT MANUFACTURER'S LITERATURE, OR THE PROCEDURE SPECIFIED IS NOT CLEARLY UNDERSTOOD. IN THE EVENT, THE CONTRACTOR FAILS TO RESOLVE THE CONFLICTS, WHICH MAY EXIST, HE SHALL BE RESPONSIBLE FOR HANDLING THE DISCREPANCIES IN A MANNER AS PRESCRIBED BY THE DESIGN AUTHORITY AT NO ADDITIONAL COST TO THE OWNER. 4. ALL PERTINENT SAFETY REGULATIONS, BOTH THE OWNER'S AND OSHA'S SHALL BE ADHERED TO RIGIDLY. IN ADDITION, ALL SAFETY PRECAUTIONS NOTED ON THE MANUFACTURER'S PRODUCT DATA SHEETS AND LABELS SHALL BE OBSERVED FOR BOTH MATERIALS AND EQUIPMENT. 5. THE APPLICATION SHALL LEAVE NO SAGS, RUNS OR HOLIDAYS. ANY DAMAGE IN ANY COAT SHALL BE REPAIRED TO CONFORM TO THIS SPECIFICATION PRIOR TO FINAL INSPECTION. 6. WHERE REQUIRED, IMPERFECTIONS AND HOLES IN SURFACES TO BE COATED SHALL BE CLEANED AND REPAIRED ACCORDING TO HIGHEST INDUSTRY STANDARDS AND IN A MANNER APPROVED BY THE DESIGN AUTHORITY. 7. ALL MATERIALS SPECIFIED FROM BENJAMIN MOORE & CO., AND ARE INTENDED TO ESTABLISH STANDARDS OF QUALITY AND GENERIC TYPES. COATING SUBSTITUTIONS ARE PROHIBITED. 8. ALL COATING MATERIALS SHALL BE DELIVERED TO OTHER JOB SITE IN THE ORIGINAL AND UNOPENED CONTAINERS, PLAINLY MARKED WITH THE PROPER DESIGNATION OF THE PRODUCT, AS WELL AS THE NAME OF THE MANUFACTURER. ALL COATING MATERIALS AT THE JOB SITE SHALL BE SUBJECT TO INSPECTION BY THE OWNER'S REP. 9. ALL PAINTING MATERIALS SHALL BE STORED IN A CLEAN, DRY WELL VENTILATED PLACE, PROTECTED FROM SPARKS, FLAME, DIRECT RAYS OF THE SUN, AND EXCESSIVE HEAT OR COLD. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE PROTECTION AND SAFETY OF THE MATERIALS STORED BY G.C. AT THE JOB SITE. 10. PAINT ADDITIVES ARE PROHIBITED. 11. COLORS FOR INDIVIDUAL ITEMS SHALL BE AS SPECIFIED IN THE FINISH PAINTING SCHEDULE, OF THIS SPECIFICATION AND/OR THE PAINTING SCHEDULE SUBMITTED AS A PART OF THE SCOPE OF WORK DOCUMENTS WITH THE SCOPE OF WORK SCHEDULE TAKING PRECEDENCE. COLORS SHALL NOT BE SUBSTITUTED. 12. SURFACES NOT TO BE PAINTED SHALL BE PROTECTED DURING CLEANING & PAINTING OPERATIONS. 13. BEFORE ANY SURFACE IS COATED, IT SHALL BE CLEANED CAREFULLY OF ALL DUST, DIRT, GREASE, LOOSE RUST, MILL SCALE, OLD PAINT, ETC. 14. ALL CLEANED METAL SHALL BE PRIME COATED , AS SPECIFIED, IMMEDIATELY AFTER CLEANING TO PREVENT NEW RUSTING OR OXIDATION OF CLEANED SURFACES. 15. SURFACES 15.1 SURFACE PREPARATION (ALL METAL AND WOOD SURFACES) a. SOLVENT CLEANING SSPC-SP1 - THIS IS A METHOD FOR REMOVING OIL, GREASE, DRAWING AND CUTTING FLUIDS FROM THE SURFACE. A COMPLETE DESCRIPTION OF THE PROCEDURES CAN BE FOUND IN STEEL STRUCTURES PANTING COUNCIL SPECIFICATION "SSPC-SP-1 SOLVENT CLEANING" b. EMULSIFIER SOLVENT CLEANING - ALL AREAS TO BE PAINTED SHOULD BE CLEANED THOROUGHLY WITH A SOLUTION OF OIL AND GREASE EMULSIFIER. THIS CLEANER EMULSIFIES ALL OF THE OILY SUBSTANCE CONVERTING IT TO SOAP AND FLOATS IF OUT OF THE SURFACE. THOROUGHLY SCRUB ALL AREAS UNTIL SURFACE APPEARS CLEAN, AND THE RINSE WELL WITH CLEAN WATER. THIS PROCESS SHOULD BE REPEATED TO ENSURE THAT THERE ARE NO OTHER OILY CONTAMINANTS REMAINING. 15.2 WALLS AND COLUMNS - EGGSHELL FINISH a. PRIMER: APPLY ONE (1) COAT OF SUPER SPEC LATEX ENAMEL UNDERCOATER & PRIMER SEALER (PRODUCT # 253) AT A WET FILM THICKNESS OF 3.6 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.1 MILS PER COAT. (TINT PRIMER ONE SHADE LIGHTER THAN FINISH COAT). b. FINISH: APPLY TWO (2) COATS OF REGAL SELECT PREMIUM INTERIOR PAINT EGGSHELL FINISH (549) AT A WET FILM THICKNESS OF 3.8 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.5 MILS PER COAT. c. APPLICATION: BRUSH SMALL AREAS AND AROUND TRIM AND CEILING WITH PREMIUM QUALITY NYLON/POLYESTER BRUSH. FIRST COAT MAY BE SPRAYED, BUT BACKROLL WITH SOFT WOVEN COVER NO LARGER THAN ½” NAP TO MINIMIZE TEXTURE. SECOND COAT SHALL BE APPLIED BY ROLLER ONLY. 15.3 CEILINGS AND SOFFITS - FLAT FINISH a. PRIMER: APPLY ONE (1) COAT OF SUPER SPEC LATEX ENAMEL UNDERCOATER & PRIMER SEALER (PRODUCT # 253) AT A WET FILM THICKNESS OF 3.6 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.1 MILS PER COAT. (TINT PRIMER ONE SHADE LIGHTER THAN FINISH COAT). b. FINISH: APPLY TWO (2) COATS OF REGAL SELECT PREMIUM INTERIOR PAINT FLAT FINISH (547) AT A WET FILM THICKNESS OF 3.8 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.4 MILS PER COAT. c. APPLICATION: BRUSH SMALL AREAS AND AROUND TRIM AND CEILING WITH PREMIUM QUALITY NYLON/POLYESTER BRUSH. FIRST COAT MAY BE SPRAYED, BUT BACKROLL WITH SOFT WOVEN COVER NO LARGER THAN ½” NAP TO MINIMIZE TEXTURE. SECOND COAT SHALL BE APPLIED BY ROLLER ONLY. 15.4 WALL BASE, CASING, AND TRIM - SEMI GLOSS FINISH a. PRIMER: APPLY ONE (1) COAT OF SUPER SPEC LATEX ENAMEL UNDERCOATER & PRIMER SEALER (PRODUCT # 253) AT A WET FILM THICKNESS OF 3.6 MILS PER COAT TO ACHIEVE : FURNISH AND INSTALL ALL GYPSUM DRYWALL AND SYSTEMS COMPLETE WITH PARTITION FRAMING, CEILING SUSPENSION SYSTEMS AND RELATED ACCESSORIES, PARTS, MATERIALS, ETC. AS SHOWN ON DRAWINGS AND AS SPECIFIED. INSTALL ALL MATERIALS PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 2. GYPSUM DRYWALL: U.S. GYPSUM 5/8" THICK FIRE CODE SHEETROCK (TYPE 'X') PANELS OF STANDARD QUALITY. GENERAL CONTRACTOR MAY USE NON-RATED 5/8" THICK BOARD IN AREAS OF STORE WHERE ALLOWED BY STATE AND LOCAL CODES. ALWAYS USE TYPE 'X' ON DEMISING WALLS. 3. FASTENERS: DRYWALL SCREWS OF PROPER SIZE AND TYPE, PER MANUFACTURER'S RECOMMENDATIONS. 4. METAL ACCESSORIES: U.S. GYPSUM OR GOLD BOND SYSTEM OF COMPONENTS AND JOINT TAPE. 5. JOINT TREATMENT: U.S. GYPSUM OR GOLD BOND SYSTEM OF COMPONENTS AND JOINT TAPE. 6. METAL FRAMING: WHERE NOT SHOWN AND SPECIFIED TO BE COLD-FORMED METAL FRAMING IN THE DRAWINGS, CONFORM TO ASTM C645 AND ASTM C754. 7. FINISHING: COMPLY WITH GYPSUM ASSOCIATION (GA) "LEVELS OF GYPSUM BOARD FINISH" - GA LEVEL 4, THREE COAT FINISHING AND SANDING IS REQUIRED FOR SURFACES INDICATED TO BE PAINTED, PROVIDE FLUSH, SMOOTH JOINTS AND SURFACES READY FOR APPLIED PAINT FINISHES. 2. 7 F. 1. A. 1. B. 1. 6 IMMEDIATELY AFTER DEMOLITION AND/OR 1 WEEK PRIOR TO FLOOR INSTALLATION. IF THE G.C. FAILS TO PROVIDE REPORT, ANY FLOOR FAILURE ATTRIBUTED TO MOISTURE, IT WILL BE THE RESPONSIBILITY OF THE G.C. TO REPLACE (LABOR AND MATERIAL). c. ALL WORK INVOLVING WATER OR MOISTURE SHOULD BE COMPLETED BEFORE FLOOR INSTALLATION. d. ROOM TEMPERATURE AND HUMIDITY OF INSTALLATION AREA SHOULD BE CONSISTENT WITH NORMAL, YEAR-ROUND LIVING CONDITIONS FOR AT LEAST A WEEK BEFORE INSTALLATION. ROOM TEMPERATURE OF 60 TO 70 DEGREE F AND HUMIDITY RANGE OF 40 TO 60% IS RECOMMENDED. e. G.C. TO STORE FLOORING AT INSTALLATION SITE FOR 72 HOURS BEFORE INSTALLATION TO ALLOW FLOORING TO ADJUST TO ROOM TEMPERATURE AND HUMIDITY. DO NOT STORE DIRECTLY ON CONCRETE OR NEAR OUTSIDE WALLS. THIS FLOORING MAY NOT BE ACCEPTABLE FOR FULL BATHROOM INSTALLATIONS BECAUSE OF MOISTURE ASSOCIATED WITH SUCH LOCATIONS. f. COMMENCEMENT OF WORK IS ACCEPTANCE OF CONDITIONS. 3. MANUFACTURERS: REFER TO FINISH SCHEDULE. 4. ADHESIVE: AS RECOMMENDED BY MANUFACTURER TO ENSURE MAXIMUM DURABILITY OVER TIME; NONTOXIC, WATERPROOF TYPE SUITABLE FOR FLOORING, SUBSTRATE, AND ACCEPTABLE TO APPLICABLE AUTHORITIES. 5. MOISTURE VAPOR PROTECTION: BOSTIK MVP4 MOISTURE BARRIER OR AS RECOMMENDED BY MANUFACTURER; ONE-PART, TROWEL APPLIED, ELASTOMERIC, MOISTURE CURE URETHANE MEMBRANE. APPLY WITH 3/16" X 5/32" V-NOTCH TROWEL IS RECOMMENDED. 6. VINYL BASE: PROVIDE 1/8" COVED BASE FOR HARD FLOOR SURFACES AND STRAIGHT (TOP SET) BASE FOR CARPETED AREAS. PROVIDE PRE-MOULDED END STOPS AND EXTERNAL CORNERS. COLOR, TYPE AND HEIGHT AS SHOWN ON THE DRAWINGS. F E 5 4 5 6 7 8 9 10 A DRY FILM THICKNESS OF 1.1 MILS PER COAT. (TINT PRIMER ONE SHADE LIGHTER THAN FINISH COAT). b. FINISH: APPLY TWO (2) COATS OF REGAL SELECT PREMIUM INTERIOR PAINT SEMI-GLOSS FINISH (551) AT A WET FILM THICKNESS OF 3.8 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.4 MILS PER COAT. c. APPLICATION: BRUSH APPLY WITH PREMIUM QUALITY NYLON/POLYESTER BRUSH. PRIMER MAY BE SPRAYED. ALWAYS KEEP A WET EDGE DURING APPLICATION. A MAXIMUM OF ONE PINT PER GALLON OF CLEAN WATER MAY BE ADDED FOR A DESIRED CONSISTENCY AND FLOW. 15.5 METAL DOORS AND METAL DOOR JAMBS - SEMI GLOSS FINISH a. PRIMER: APPLY ONE (1) COAT OF SUPER SPEC HP ACRYLIC METAL PRIMER (P04) AT A WET FILM THICKNESS OF 4.0-4.5 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.7-2.3 MILS PER COAT. (TINT PRIMER ONE SHADE LIGHTER THAN FINISH COAT). b. FINISH: APPLY TWO (2) COATS OF REGAL SELECT PREMIUM INTERIOR PAINT SEMI-GLOSS FINISH (551) AT A WET FILM THICKNESS OF 3.8 MILS PER COAT TO ACHIEVE A DRY FILM THICKNESS OF 1.4 MILS PER COAT. c. APPLICATION: FOR JAMBS: BRUSH APPLY WITH PREMIUM QUALITY NYLON/POLYESTER BRUSH. ALWAYS KEEP A WET EDGE DURING APPLICATION. FOR DOORS, A SOFT WOVEN COVER OF NO MORE THAN ½” IS RECOMMENDED FOR A SMOOTH APPEARANCE. A MAXIMUM OF ONE PINT PER GALLON OF CLEAN WATER MAY BE ADDED FOR A DESIRED CONSISTENCY AND FLOW. 15.6 CONCRETE FLOOR SEALERS: PROVIDE AS INDICATED ON THE DRAWINGS OR, IF NOT INDICATED THERE PROVIDE AS FOLLOWS FOR ALL EXPOSED CONCRETE AREAS WITHOUT A SPECIFIED FINISH a. INTERIOR CLEAR CONCRETE FLOOR SEALER (WATER-BASED) MP1#58, H&C SILICONE ACRYLIC CONCRETE SEALER, APPLIED PER MANUFACTURER'S WRITTEN INSTRUCTIONS. b. EXTERIOR CLEAR CONCRETE SEALER MP1#99, H&C CONCRETE & MASONRY WATER PROOFING SEALER, APPLIED PER MANUFACTURER'S RECOMMENDATIONS. 15.7 NOTES AND CAUTIONS a. ENSURE PROPER CONDITIONS FOR APPLICATION - BEFORE ANY SURFACE IS COATED, IT SHALL BE CLEANED OF ALL DUST, DIRT, GREASE, LOOSE RUST, MILL SCALE, LOOSE PAINT, ETC. IMPERFECTIONS AND HOLES IS SURFACES TO BE COATED SHALL BE CLEANED AND FILLED IN AN APPROVED MANNER. b. ALL PROJECTS SHOULD BE INSPECTED - AT VARIOUS STAGES OF SURFACE PREPARATION AND COATING APPLICATION. INSPECTIONS SHOULD BE CARRIED OUT BY G.C. INSPECTION & OWNERS REP. OR BY OUTSIDE INSPECTION FIRMS. c. CLEAN ANY BOLTS AND PAINT THEM USING A BRUSH - COLORS SHOULD BE DEGREASED BEFORE PRIMING. THE PRIMER AND TOPCOATS SHOULD BE APPLIED BY BRUSH TO ACHIEVE COMPLETE AND UNIFORM COVERAGE. d. MASK FAYING SURFACES AFTER PRIMING - IF FAYING SURFACES ARE TO BE PRIMED, THEY MUST BE MASKED AFTER PRIMING TO PREVENT TOPCOATING OF THE FAYING SURFACES. APPLICATION OF THE TOPCOAT TO A FAYING SURFACE MY LEAD TO LOOSENING OF FRICTION JOINTS. e. ENSURE ADEQUATE VENTILATION - ADEQUATE VENTILATION WHILE APPLYING AND CURING COATINGS IS IMPORTANT FOR HEALTH AND SAFETY REASONS AND TO ENSURE PROPER CURING OF THE COATING. WHEN APPLYING COATINGS IN CONFINED SPACES, SOLVENT VAPORS MAY ACCUMULATE, LEADING TO INTOXICATION OF WORKERS OR FIRE AND EXPLOSION. FLAMMABLE SOLVENTS AND THE ATOMIZED COATINGS ARE GENERALLY HEAVIER THAN AIR AND TEND TO SETTLE IN THE LOWER AREAS OF CONFINED CONSIDER THIS WHEN DESIGNING AND INSTALLING THE VENTILATION SYSTEM. f. PAINT BEFORE INSTALLING HARDWARE. G. 1. GENERAL: INSTALL VINYL WALL COVERING AND PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. 2. MAINTENANCE INSTRUCTIONS: FURNISH MANUFACTURER'S RECOMMENDED CLEANING MATERIALS AND APPLICATION METHODS, INCLUDING PRECAUTIONS IN USE OF CLEANING MATERIALS WHICH MAY BE DETRIMENTAL TO SURFACES. 3. MANUFACTURER: AS NOTED ON DRAWINGS. 4. TYPE: VINYL WALL COVERING CONFORMING TO FS DD-G-408, TYPE II VINYL WALL COVERING WITH CLOTH BACKING, MINIMUM 24 TO 26 OZ.; WITH MAXIMUM 25 FLAME SPREAD AND SMOKE DEVELOPED, ASTM E84 (UL CLASS A, UBC CLASS I). 5. ADHESIVE: NONTOXIC TYPE RECOMMENDED BY WALL COVERING MANUFACTURER TO SUIT APPLICATION. 6. PRIMER: PROVIDE NON-STAINING, NON-TOXIC RELEASE COAT PRIMER AS RECOMMENDED BY WALL COVERING MANUFACTURER. a. PROVIDE PRIMER WHICH ALLOWS REMOVAL OF WALL COVERING FROM GYPSUM BOARD WITHOUT DAMAGING PAPER FACING OF BOARD, AND WITHOUT PREMATURE SEPARATION OF WALL COVERING FROM WALL. 7. EXAMINATION: ENSURE SURFACES TO RECEIVE WALL COVERING ARE CLEAN, TRUE AND FREE OF IRREGULARITIES, DO NOT COMMENCE WITH WORK UNTIL SURFACES ARE SATISFACTORY. a. ENSURE WALL SURFACE FLATNESS TOLERANCE DOES NOT VARY MORE THAN 1/8" IN 10'-0", NOR VARY AT A RATE GREATER THAN 1/16" PER RUNNING FOOT. 8. PREPARATION: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS; FILL NICKS, GOUGES AND OTHER MINOR IMPERFECTIONS OF SUBSTRATES WITH LATEX FILLER; SAND SMOOTH, FLUSH WITH SURFACE; APPLY PRIME COAT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 9. APPLICATION: HANDLE AND APPLY WALL COVERING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS; MIX AND APPLY ADHESIVE IN ACCORDANCE WITH ADHESIVE MANUFACTURER'S RECOMMENDATIONS. a. USE FABRIC PANELS IN EXACT ORDER AS CUT FROM ROLLS; USE ROLLS IN CONSECUTIVE ORDER AS NUMBERED BY MANUFACTURER. b. HORIZONTAL SEAMS AND CUTTING AT CORNERS ARE NOT ACCEPTABLE; CUT NO CLOSER THAN 2" OF AN INSIDE CORNER, AND NOT CLOSER THAN 6" OF AN OUTSIDE CORNER. c. FILL SPACES ABOVE AND BELOW WINDOWS, DOORS, AND SIMILAR AREAS IN SEQUENCE FROM ROLL. 11 H. 1. 2. 3. 4. 5. 6. 7. I. 1. 2. J. 1. 2. 12 13 14 GENERAL: PROVIDE TOILET ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS WITH DISABILITIES. MANUFACTURERS: AS NOTED ON DRAWINGS. TYPES: STAINLESS STEEL ACCESSORIES AS INDICATED ON DRAWINGS; PROVIDE GRAB BARS WITH CONCEALED MOUNTING, SIZES AND SHAPES AS INDICATED AND AS REQUIRED BY APPLICABLE CODES AND REGULATIONS. MATERIALS: STAINLESS STEEL, ASTM A666, COMMERCIAL GRADE, TYPE 302/304, NUMBER 4 SATIN FINISH, SATIN CHROME ACCEPTABLE WHERE STAINLESS STEEL IS NOT AVAILABLE FOR ACCESSORY ITEM SCHEDULED; GAGES AS STANDARD WITH MANUFACTURER OF SPECIFIED ITEMS. a. FASTENERS, SCREWS, AND BOLTS: HOT DIP GALVANIZED; AS RECOMMENDED BY ACCESSORY MANUFACTURER FOR COMPONENT AND SUBSTRATE. b. CONCEALED SURFACES: PRETREAT AND CLEAN, SPRAY APPLY ONE COAT PRIMER AND BAKED ENAMEL FINISH. FABRICATION: WELD AND GRIND SMOOTH JOINTS OF FABRICATED COMPONENTS; FORM EXPOSED SURFACES FROM ONE SHEET OF STOCK, FREE OF JOINTS. a. FABRICATE UNITS WITH TIGHT SEAMS AND JOINTS, EXPOSED EDGES ROLLED; HANG DOORS AND ACCESS PANELS WITH CONTINUOUS PIANO HINGES; PROVIDE CONCEALED ANCHORAGE WHERE POSSIBLE. b. PROVIDE STEEL ANCHOR PLATES AND ANCHOR COMPONENTS FOR INSTALLATION. c. FORM SURFACES FLAT WITHOUT DISTORTION; MAINTAIN FLAT SURFACES WITHOUT SCRATCHES AND WITHOUT DENTS; FINISH EXPOSED EDGES EASED, FREE OF SHARP EDGES WHERE POTENTIAL EXISTS FOR PHYSICAL CONTACT. d. HOT DIP GALVANIZE FERROUS METAL ANCHORS AND FASTENING DEVICES. e. SHOP ASSEMBLE COMPONENTS; PACKAGE COMPLETE WITH ANCHORS AND FITTINGS. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES AND REGULATIONS. 9 10 CONSULTANT PROJECT # 150343 Shremshock Architects, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com Gerald S. Shremshock, Architect Timothy J. Shremshock, Architect SEAL FIRE EXTINGUISHERS, CABINETS, AND ACCESSORIES AS REQUIRED BY APPLICABLE CODE. a. COMPLY WITH NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS. b. LISTED AND LABELED FOR TYPE, RATING, AND CLASSIFICATION BY AN INDEPENDENT TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. PRODUCTS a. FIRE EXTINGUISHERS: PORTABLE MULTIPURPOSE DRY-CHEMICAL TYPE, UL RATED 4-A: 60-B:, 10-LB NOMINAL CAPACITY, IN ENAMELED STEEL CONTAINER. b. FIRE EXTINGUISHER CABINETS: SIZED TO FIT FIRE EXTINGUISHER; APPROVED BY ARCHITECT. GENERAL: INSTALL STORAGE SHELVING AS INDICATED ON THE DRAWINGS; PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. INSTALL UNITS AND ACCESSORIES AT LOCATIONS SHOWN IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS, LEVEL, PLUMB, SECURE AND AT PROPER HEIGHT K. 1. PROVIDE SIGNAGE AS INDICATED ON THE DRAWINGS. COMPLY WITH APPLICABLE PROVISIONS IN ADA-ABA ACCESSIBILITY GUIDELINES AS APPLICABLE 2. ALL COLORS, TYPE, STYLE, FONT SIZE AND MATERIALS TO BE AS SHOWN ON DRAWINGS AND AS SELECTED AND APPROVED BY OWNER. 3. LOCATE SIGNS WHERE INDICATED, USING MOUNTING METHODS OF TYPES DESCRIBED AND COMPLYING WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, EXCEPT WHERE MORE STRINGENT REQUIREMENTS APPLY. A. GENERAL CONTRACTOR IS RESPONSIBLE FOR ASSEMBLY AND PLACEMENT OF OFFICE AND NON-SALES EQUIPMENT AND FURNITURE. B. THE CONTRACTOR IS RESPONSIBLE TO UNCRATE, ASSEMBLE, AND PLACE TRADE FIXTURES AND PRESENTATION ITEMS IN SALES AREA; FIXTURES TO BE LOCATED PER THE DIRECTION OF THE OWNER. A. ACCESS PANEL: FOR GYPSUM BOARD SOFFIT OR WALL (COLOR TO MATCH ADJACENT FINISH): 24" X 24" SURFACE MOUNTED, MODEL #AP24, AS MANUFACTURED BY INTEXFORMS INC. (916) 388-9933 OR OTHER WHICH MUST BE APPROVED BY OWNERS CONSTRUCTION MANAGER. SUBSTITUTE WITH "B" LABEL FIRE PANEL, MODEL FW 5050, KEY LOCK, ONLY IF A RATED DOOR IS REQUIRED PER CODES. B. ACCESS PANELS: FOR HVAC EQUIPMENT ARE NORMALLY INDICATED ON THE HVAC AND REFLECTED CEILING PLANS. IN ABSENCE OF DEFINED LOCATIONS, THE GENERAL CONTRACTOR IS TO FURNISH AND INSTALL ACCESS PANELS AS NECESSARY TO FURNISH REASONABLE, SAFE ACCESS TO SERVICE ALL SERVICEABLE COMPONENTS OF EACH PIECE OF EQUIPMENT. ASSUMED ACCESS SHALL BE BY A TECHNICIAN(S) STANDING FIRMLY ON A LADDER. WHERE ACCESS PANELS OR REMOVABLE DIFFUSERS CANNOT BE LOCATED IMMEDIATELY ADJACENT TO THE EQUIPMENT, C. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ASSEMBLE ALL MISCELLANEOUS NON-SALES AREA WALL STANDARDS, SHELVES, BRACKETS, ETC. D. LAVATORY FIXTURES & ACCESSORIES: REFER TO MECHANICAL DRAWINGS, TOILET ROOM DETAILS SHEET, AND RESPONSIBILITY SCHEDULE. E. RESTORE LANDLORD'S STRUCTURAL STEEL FIREPROOFING TO MAINTAIN INTEGRITY OF SAME AND FIREPROOF NEW STEEL AS REQUIRED. F. CLEANING: THE G.C. IS RESPONSIBLE FOR 2 PROFESSIONAL CLEANINGS. ONE CLEANING TO BE PRIOR TO THE PUNCH-LIST DATE. THE SECOND IS TO BE AFTER THE STORE IS MERCHANDISED BEFORE THE OPENING DATE. STORE IS TO BE TURNED OVER IN A DUST-FREE, DIRT-FREE CONDITION. CLEANING SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: 1. STOREFRONT GLASS (INSIDE AND OUT) 2. MIRRORS 3. STOREFRONT METAL 4. SIGNS 5. LIGHT FIXTURES INCLUDING CANS, TRIM, TRACK AND TRACK HEADS 6. FLOORING (PER MANUFACTURER'S RECOMMENDATIONS) 7. VINYL RESILIENT FLOOR TILE CLEANED AND WAXED 8. PRESENTATION ITEMS, PROPS, AND TRADE FIXTURES 9. WOOD BASE 10. WALL COVERINGS 11. NON-SALES SHELVING, STORAGE PLATFORMS, ETC. G. - GENERAL: G.C. TO COORDINATE AWNING AND FRAME INSTALLATION WITH OWNER'S PROJECT MANAGER. SUBCONTRACTOR TO PROVIDE BLOCKING AS REQUIRED. COORDINATE WITH OWNER'S VENDOR. 8 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 LA PLAZA MALL K 2 AT 1 SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 DRAWN BY: ALW REVIEWED BY: MLH/JMA AUTHORIZED FOR: ARCHITECTURAL SPECIFICATIONS A-702 11 12 13 14 3 4 5 6 HVAC LEGEND J INCLINED RISE IN DUCT 12"Ø ROUND DUCTWORK. DIAMETER IN INCHES. DROP INCLINED DROP IN DUCT 20/12 RECTANGULAR DUCTWORK. SIZE IN INCHES, FIRST NUMBER IS SIDE SHOWN. TURNING VANES SUPPLY OR OUTSIDE AIR DUCT POINT OF CONNECTION - NEW TO EXISTING RETURN , RELIEF OR EXHAUST AIR DUCT. MANUAL VOLUME DAMPER DIFFUSER/GRILLE LABEL: A - TYPE/DESIGNATION B - NECK SIZE (INCHES) C - AIRFLOW (CFM) FIRE DAMPER THERMOSTAT C T H 1. 2. 3. 4. 5. SENSOR SD RADIUS DUCTWORK ELBOW - ROUND OR RECTANGULAR. RECTANGULAR DUCTWORK BRANCH TAKE-OFF WITH 45 DEGREE BRANCH INLET. CARBON DIOXIDE SENSOR 6. DUCT SMOKE DETECTOR 7. SHEET KEYNOTE REFERENCE 8. 9. 10. ROUND Ø UC UNDERCUT DOOR 3/4" FOR AIRFLOW 11. ACCESS PANEL HIGH EFFICIENCY TAP WITH DAMPER AND FLEX DUCT (AT DIFFUSER CONNECTION). SWITCH S ROUND DUCT BRANCH TAKE-OFF FROM RECTANGULAR MAIN WITH CONICAL TAP. RECESSED MOUNTED SPRINKLER HEAD DUCTWORK SIZE TRANSITION. EXISTING RETURN/SUPPLY CALL OUT 12. 13. OPEN CEILING UPRIGHT SPRINKLER HEAD (E)X X XXX SPIN-IN W/ DAMPER X SUPPLY OR OUTSIDE AIR DUCT UP SUPPLY OR OUTSIDE AIR DUCT DOWN X XXX X RETURN AIR DUCT UP 14. 15. 16. 17. DIFFUSER CALL OUT NECK AND BRANCH DUCT SIZE CFM FOR BALANCE PURPOSES RETURN CALL OUT NECK AND BRANCH DUCT SIZE CFM FOR BALANCE PURPOSES SPIN-IN W/O DAMPER G 11 X XXX 18. 19. 20. 21. 22. 23. F 24. - - E (E)RTU 2 25. ADJACENT TENANT (N.I.C.) (E) SUPPLY & RETURN TRUNKS 26. 4 27. USER: JGRAY PLOTTED: 7/16/2015 - 4:03 PM 3 D 29. 14/12 3 (E) INSULATED ROOF DRAIN @ +/- 14'-11 1/2" A.F.F. S1 12 500 33. (E) ELECTRICAL CONDUIT RACK @ +/- 15'-0" A.F.F. S AP (E) ROOF DRAIN LEADS DOWN THROUGH ROOF DECK C PIPES ENTER WALL @ +/5 14'-0" A.F.F. 35. 36. 37. 38. MALL COMMON AREA 100 POSSIBLE VENT STACK LEADS THROUGH ROOF. BOTTOM OF PIPE ENTERS REAR DEMISING WALL @ +/- 12'-0" A.F.F. 34. 5 TC SALES (TYP) 6 5 30. 31. 32. 5 - ADJACENT TENANT (N.I.C.) 5 28. S 12/14 P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\M-101_06078.dwg LAYOUT: M-101 - RTU 14 900 12 13 14 GENERAL NOTES HUMIDISTAT 90 DEGREE DUCTWORK ELBOW W/ TURNING VANES. H 10 GENERAL CONTRACTOR SHALL RELOCATE EXISTING THERMOSTAT TO LOCATION AS SHOWN ON PLAN. EXTEND CONTROL WIRING FROM THERMOSTAT TO HVAC UNIT AS REQUIRED. CLEAN AND ADJUST AS REQUIRED FOR PROPER OPERATION. REPAIR/REPLACE ANY DEFECTIVE PARTS AND MAKE SYSTEM FULLY FUNCTIONAL. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO BID. 2. : GENERAL CONTRACTOR TO REUSE EXISTING ROOF TOP UNIT. PROVIDE 3 SETS OF 2" FILTERS, CHANGE FILTER AFTER FINAL STORE CLEANING AND AGAIN PRIOR TO AIR BALANCE. CLEAN COILS, REBALANCE FAN AND REPLACE BELTS, REPLACE/REPAIR ANY DEFECTIVE PARTS. GREASE (IF REQUIRED) FAN BEARINGS. CHECK CONTROLS FOR PROPER OPERATION AND MOTOR FOR PROPER FAN PERFORMANCE. CLEAN AND/OR REPLACE CONDENSATE LINE AS REQUIRED. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. VERIFY OUTSIDE AIR DAMPER IS IN GOOD WORKING ORDER PRIOR TO CONSTRUCTION. BALANCE SUPPLY AND OUTSIDE AIR DAMPER TO CFM SPECIFIED. 3. GENERAL CONTRACTOR TO FURNISH AND INSTALL AIR DEVICES PER SCHEDULE ON SHEET M-301. EXTEND DUCTWORK TO AIR DEVICE AS SHOWN. SEAL ALL JOINTS AIRTIGHT. BALANCE TO CFM AS INDICATED ON PLAN. R EFER TO DUCT MOUNTING DETAIL ON SHEET M-501. 4. CONNECT TO EXISTING SUPPLY AND RETURN AIR DUCT DROPS. CLEAN AND REPAIR EXISTING DUCTWORK AS REQUIRED TO ENSURE PROPER OPERATION. PATCH AND REPAIR ANY UNUSED OPENING. PATCH AND REPAIR INSULATION IF REQUIRED. TRANSITION TO DUCT SIZE SHOWN. 5. EXISTING UTILITIES TO REMAIN. FIELD VERIFY EXISTING SIZE AND LOCATION. 6. SPRINKLER HEADS SHOWN FOR REFERENCE ONLY. LICENSED FIRE PROTECTION PROFESSIONAL TO DETERMINE ACTUAL AMOUNT AND LOCATION OF HEADS. ALIGN SPRINKLER HEAD LOCATIONS WITH LIGHTS AND OTHER CEILING ELEMENTS. COORDINATE WITH LANDLORD AND TENANT. IN-LINE 90 DEGREE DROP (RISE) IN DUCT RISE B 9 1. RETURN AIR DUCT DOWN RETURN AIR GRILLE A 8 KEY NOTES SUPPLY AIR DIFFUSER - HATCHED PATTERN INDICATES BLOCKED DIRECTIONAL AIR FLOW AS SHOWN. K 7 ALL WORK MUST COMPLY WITH THE REQUIREMENTS OF LOCAL CODES AND ORDINANCES. WHERE INSPECTIONS ARE REQUIRED BY AUTHORITIES HAVING JURISDICTION, WORK MUST NOT BE CONCEALED UNTIL INSPECTIONS AND TESTING ARE COMPLETED AND ACCEPTED. PRIOR TO BID, CONTRACTOR MUST BECOME THOROUGHLY FAMILIAR WITH THE REQUIREMENTS OF THE GENERAL NOTES AS WELL AS ALL OTHER NOTES SHOWN ON THE CONTRACT DOCUMENTS. VISIT THE SITE TO ESTABLISH THE EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO ANY DUCT, PIPE OR EQUIPMENT FABRICATION. SYSTEMS MUST BE ERECTED USING CONTRACTOR'S FIELD MEASUREMENTS FOR COORDINATION WITH EQUIPMENT, STRUCTURE, FIRE PROTECTION AND ELECTRICAL CONDITIONS IN THE SPACE. ALL CONTRACT DOCUMENTS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENTS OR GEOMETRICAL RELATIONSHIPS OF EQUIPMENT AND SERVICES. THEY ARE NOT INTENDED TO SPECIFY OR SHOW EVERY OFFSET, SEQUENCE, DEVICE, OPTION, FITTING, OR COMPONENT. THE CONTRACT DOCUMENTS REFLECT A SYSTEM DESIGNED AROUND SPECIFIC REFERENCE PRODUCTS, THE SELECTION OF WHICH HAS IMPACTED THE DESIGNS OF OTHER TRADES. IF ALTERNATE MANUFACTURERS ARE SUBMITTED OR BID, IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE ALL DIFFERENCES AND IMPACTS WITH ALL TRADES PRIOR TO BID, INCLUDING COSTS ASSOCIATED WITH REQUIRED CHANGES TO OTHER TRADES. NO EXTRAS WILL BE ALLOWED FOR CHANGES REQUIRED TO OTHER TRADES IF ALTERNATE EQUIPMENT IS BID OR INSTALLED AT THE CONTRACTOR'S OPTION. EXISTING MECHANICAL INFORMATION IS BASED ON LIMITED EXISTING BUILDING DRAWINGS AND FIELD WORK. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED FOR REVISIONS TO THE DESIGN TO CORRECT FOR EXISTING CONDITIONS NOT AS INDICATED ON THE PLANS. CONTRACTOR SHALL NOTIFY OWNER, ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR INCREASE THE SCOPE OF WORK FROM THAT IS DESCRIBED IN THE DOCUMENTS. FIELD VERIFY EXACT CONDITIONS AND ROUTING OF WORK. CONTACT THE ENGINEER OR ARCHITECT IMMEDIATELY SHOULD ANY CONFLICT ARISE. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE CONFLICTS PRIOR TO BIDDING. ANYTHING NOT NOTED AS EXISTING IS TO BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT. INFORMATION AND COMPONENTS SHOWN ON DIAGRAMS OR DETAILS, BUT NOT SHOWN ON PLANS, AND VICE VERSA, MUST BE PROVIDED AS IF EXPRESSLY REQUIRED BY BOTH. REFER TO DRAWINGS, GENERAL NOTES OF OTHER DISCIPLINES, AND PROJECT SPECIFICATIONS FOR ADDITIONAL PROJECT INFORMATION AND REQUIREMENTS. NOTIFY ENGINEER OF ANY CONFLICTS BETWEEN THE INFORMATION PRESENTED AND FIELD CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING/PATCHING RELATED TO THEIR WORK. IF THE SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. CONSTRUCTION MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED TYPE PER NFPA 70. COORDINATE LOCATION AND ELEVATION OF MECHANICAL WORK WITH ALL DUCTWORK, LIGHT FIXTURES, AND OTHER CEILING BUILT-IN FIXTURES. CONTACT ENGINEER OR ARCHITECT IMMEDIATELY SHOULD ANY CONFLICT ARISE. REFER TO MALL CRITERIA MANUAL FOR ADDITIONAL STANDARDS AND REQUIREMENTS. COORDINATE ALL THERMOSTAT/SENSOR LOCATIONS WITH FURNITURE LAYOUT AND ARCHITECTURAL PLANS. CHANGES IN DUCT SIZES SHALL BE MADE BY UNIFORM TAPER SECTION WITH A MAXIMUM INCLUDED ANGLE OF DIVERGENCE OF 15 DEGREE. DUCT SIZE DIMENSIONS INDICATED REPRESENT INTERNAL FREE AREA. INCLUDE ADDITIONAL ALLOWANCE FOR INSULATION. ALL SUPPLY, AND MAKE-UP AIR DUCTWORK TO BE SHEET METAL CONSTRUCTION AND EXTERNALLY INSULATED. BRANCH DUCTS SERVING DIFFUSERS SHALL BE SIZED TO MATCH DIFFUSER NECK SIZE INDICATED. ALL ROUND DUCT ELBOWS SHALL BE LONG SWEEP, 1-1/2 TIMES THE CENTERLINE RADIUS. IT IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS, PLUMBING LOCATIONS, ELECTRICAL RUNS AND POINTS OF CONNECTION TO EXISTING DUCT SYSTEMS. ADDITIONALLY, MECHANICAL CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS HVAC EQUIPMENT, DUCTWORK, ETC. PRIOR TO COMMENCING ANY WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE MECHANICAL EQUIPMENT COMPONENTS ARE INSTALLED AT LOCATIONS AND ELEVATIONS WHICH MAKE THEM READILY ACCESSIBLE FOR ROUTINE MAINTENANCE WITHOUT REQUIRING ANY EXTRAORDINARY MEASURES. THE OWNER RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND SPECIFICATIONS. SHOULD THE OWNER FIND CORRECTIVE WORK NECESSARY, HE WILL NOTIFY CONTRACTOR OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS DEEMED TO BE NECESSARY, THE COST OF REINSPECTIONS WILL BE BORNE BY THE CONTRACTOR. IF WORK IS REQUIRED BY OWNER IN ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION, WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE STORE, CONTRACTOR SHALL BE DIRECTED BY TENANT TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT THE CONTRACTOR CAN NOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE, THE OWNER MAY AT HIS DISCRETION TAKE OVER SUCH WORK AND BACK CHARGE THE CONTRACTOR FOR ANY CORRECTIVE WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND/OR ADHERENCE TO PLANS AND SPECIFICATIONS. FIRE DAMPERS SHALL BE FURNISHED WITH INTERLOCKING HINGED BLADES. ALL DAMPERS SHALL BE UL APPROVED AND LABELED AND SHALL MEET ALL REQUIREMENTS OF NFPA NO 90A. FURNISH WITH UL LABELED FUSIBLE LINKS WITH TEMPERATURE RANGES TO CONFORM TO NFPA REQUIREMENTS. ALL FIRE DAMPERS SHALL BE TYPE "B" WITH BLADES OUT OF THE AIRSTREAM AND RATED FOR USE IN DYNAMIC SYSTEMS. ALL ROOF PENETRATIONS, PATCHING AND FLASHING SHALL BE PERFORMED BY A LANDLORD APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. COORDINATE ROOF PENETRATIONS AND ROOFTOP EQUIPMENT LOCATIONS WITH LANDLORD AND GENERAL CONTRACTOR. NOTHING IS PERMITTED TO BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THE ROOF DECK. CONTRACTOR MAY ATTACH TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL WHICH EXISTS ABOVE THE TENANT SPACE. COORDINATE FINAL ROOFTOP UNIT LOCATIONS WITH LANDLORDS STRUCTURAL ENGINEER. ROOFTOP UNITS AND MAKE-UP AIR UNIT TO BE LOCATED WITHIN STRUCTURAL BAY. PROVIDE 10' CLEARANCE FROM UNIT OUTSIDE AIR INTAKE TO ANY EXHAUST/VENTS ON ROOF. ALL ROOFTOP UNITS TO BE LOCATED ON FACTORY SUPPLIED ROOF CURBS. UNLESS NOTED OTHERWISE. PROVIDE AND INSTALL ALL ROOFTOP UNIT EQUIPMENT WITH SPRING ISOLATORS ON ROOF CURB. GENERAL CONTRACTOR TO LABEL ALL ROOFTOP EQUIPMENT WITH TENANT NAME, SPACE NUMBER AND EQUIPMENT IDENTIFICATION (RTU-1, ETC.), PER MALL SPECIFICATIONS AND STANDARDS. PITCH POCKETS ARE NOT PERMITTED ON THE ROOF FOR CONDENSATE DRAINS, POWER OR CONTROL WIRING. ALL CONNECTIONS ARE TO BE MADE INSIDE THE EQUIPMENT CURB OR THROUGH PRE-MANUFACTURED PIPING CURB. PROVIDE SAFE MEANS OF ACCESS HATCHES (24"x24") FOR ALL MECHANICAL EQUIPMENT LOCATED ABOVE A HARD CEILING. COORDINATE W/ ARCHITECTURAL CEILING PLANS. CONTRACTOR MUST REPLACE ALL AIR FILTERS IN HVAC UNITS WITH NEW CLEAN FILTERS BEFORE AIR BALANCING AND PRIOR TO FINAL TURNOVER TO TENANT. PROVIDE AND INSTALL ADJUSTABLE VOLUME CONTROL DEVICE FOR EACH SUPPLY AND DUCTED RETURN DIFFUSER AND REGISTER. ALL ROOFTOP UNIT CONNECTIONS (SUPPLY AND RETURN) TO BE WITH FLEXIBLE CONNECTORS. REFER TO RESPONSIBILITY SCHEDULE ON SHEET G-002. S1 12 500 T (E) 8" DIAMETER SPRINKLER MAIN @ 14'-0" A.F.F. 3 SEAL SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM - STOCK ROOM 101 SGH STORE #: 6078 5 ADJACENT TENANT (N.I.C.) DRAWN BY: CH (E) SPRINKLER PIPE @ +/- 14'-0" A.F.F. REVIEWED BY: JTP AUTHORIZED FOR: A MECHANICAL PLAN & LEGEND PLAN NORTH A1 M-101 MECHANICAL PLAN 2 Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com TX Registration Number: #F-9566 5 FE B 1 CONSULTANT PROJECT # 150343 1 S SCALE: A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 LA PLAZA MALL 2 AT 1 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 THERMOSTAT SCHEDULE K MODE HEAT SPRINKLER SYSTEM NOTES UNOCCUPIED OCCUPIED 68F 60F COOL 80F 73F OCCUPIED MODE: MONDAY-SATURDAY 8:00a.m.-9:00p.m. SUNDAY 11:00a.m.-6:15p.m. J H TAG SERVICE MOUNTING MFR S1 SUPPLY AIR LAY-IN TITUS TMS 24" X 24" R1 RETURN AIR LAY-IN TITUS 355RL 24" X 24" MODULE SIZE FINISH SEAL DESIGN STANDARDS: HARD CEILING AREA AT STOREFRONT: WHITE CONCEALED HEADS; RELIABLE MODEL 'G-4'; TYCO 'RF-11' CEILING TILE AT RETAIL, OD, AND LENS PROCESS: RECESSED CHROME HEADS WITH WHITE TRIM RINGS; RELIABLE MODEL "G-F1'; TYCO 'TY-L' CEILING TILE AT LOUNGE, OFFICE, AND BACK OF HOUSE: CHROME HEADS WITH CHROME TRIM RINGS; RELIABLE MODEL "G"; 'TY-L' NOTES STD. WHITE FINISH STD. WHITE FINISH Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com TX Registration Number: #F-9566 FOR EXISTING FIRE SPRINKLER SYSTEM: CONTRACTOR SHALL REWORK AND MODIFY THE SYSTEM IF NECESSARY FOR THE NEW SPACE CONFIGURATION. MODIFICATIONS SHALL BE DESIGNED AND INSTALLED BY A QUALIFIED FIRE SPRINKLER CONTRACTOR, WHO SHALL PREPARE DESIGN/SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO THE LANDLORD AND BUILDING AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA, STANDARD 101, AND ANY OTHER STATE OR LOCAL CODES HAVING JURISDICTION. GRILLE, REGISTER AND DIFFUSER SCHEDULE MODEL No. CONSULTANT PROJECT # 150343 FOR NEW FIRE SPRINKLER SYSTEM: CONTRACTOR SHALL PROVIDE A COMPLETE FIRE PROTECTION SPRINKLER SYSTEM FOR THE ENTIRE SPACE IN COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS AND THE LANDLORD'S CRITERIA. THE CONTRACTOR SHALL HAVE DRAWINGS, SHOP DRAWINGS, APPLICATIONS AND SUBMITTALS PREPARED BY A PROPERLY LICENSED PROFESSIONAL, WHO IS APPROVED BY THE LANDLORD. ALL DRAWINGS AND CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL CODES, REGULATIONS, INSURANCE ASSOCIATIONS AND RATING BUREAUS AND SHALL INCLUDE ALL PERMITS, TESTS, SHUT DOWN FEES AND CERTIFICATIONS TO PROVIDE A COMPLETE IN PLACE SYSTEM. 2 2 1. OPPOSED BLADE DAMPER G 2. LAY IN FRAME FOR T-BAR CEILING 3. PROVIDE WITH RAPID MOUNT FRAME FOR DRY WALL CEILING 4. MOUNT HIGH ON WALL ABOVE CEILING TO PROVIDE TRANSFER AIR INTO SALES PLENUM G11 SCALE: SPRINKLER SYSTEM NOTES EXISTING ROOFTOP HVAC UNIT SCHEDULE TAG MFR MODEL No. NOMINAL TONS SEER MIN OA (CFM) 3 15 150 E USER: JGRAY PLOTTED: 7/16/2015 - 4:03 PM P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\M-301_06078.dwg LAYOUT: M-301 RTU (E)RTU CARRIER 50HCA04 COOLING DATA ELECTRIC HEAT DATA INPUT (KW) OUTPUT (MBH) VOLTAGE (V/ɸ/Hz) UNIT MCA UNIT MOCP 6.5 - 208/3/60 30 30 SUPPLY AIR (CFM) ESP (IN WC) MOTOR (HP) EAT DB/WB LAT DB/WB TOTAL (MBH) 1000 0.8 0.6 75/67 - 35.5 SENSIBLE COOLING HEATING (MBH) STAGES STAGES 20.0 1 - UNIT CHARACTERISTICS AT SUPPLY FAN DATA NOTES/ OPERATING ACCESSORIES WEIGHT (LBS) - - LA PLAZA MALL F D C SUNGLASS HUT LA PLAZA MALL OUTSIDE AIR SCHEDULE SPACE DESIGNATION FLOOR AREA (SF) SPACE OUTSIDE AIR REQUIREMENTS (ASHRAE 62.1) OCCUPANCY B SALES FLOOR 464 8 CFM PER CFM PER PERSON SF 7.5 SERVICE OUTSIDE AIR (CFM) (E)RTU 150 MINIMUM CFM 145 0.12 MINIMUM OUTSIDE AIR DELIVERED = 150 CFM MINIMUM OUTSIDE AIR REQUIRED = 145 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 DRAWN BY: CHC REVIEWED BY: JTP AUTHORIZED FOR: MECHANICAL SCHEDULES A A1 SCALE: MECHANICAL SCHEDULES 1 2 A11 SCALE: 3 4 5 6 7 8 9 10 HVAC CALCULATIONS 11 12 M-301 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ABBREVIATIONS ABOVE AIR CONDITIONER, AIR CONDITIONING, ABOVE CEILING AFF ABOVE FINISHED FLOOR ARCH ARCHITECT, ARCHITECTURAL ARI AIR CONDITIONING & REFRIG INSTITUTE ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATION & AC ENGINEERS K J H G B/F BAS BD BLDG BMS BOD BOP BOS BTU BELOW FLOOR BUILDING AUTOMATION SYSTEM BACKDRAFT DAMPER BUILDING BUILDING MANAGEMENT SYSTEM BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STRUCTURE BRITISH THERMAL UNIT CFH CFM CL CLG CO CONN COP CW °C CUBIC FEET PER HOUR CUBIC FEET PER MINUTE CENTERLINE CEILING CLEANOUT CONNECT, CONNECTION CLEANOUT PLUG COLD WATER DEGREES CELSIUS DB dB DDC DEG DIA (Ø) DIM DISC DN DWG DX DRY BULB DECIBEL DIRECT DIGITAL CONTROL DEGREES DIAMETER DIMENSION DISCONNECT DOWN DRAWING DIRECT EXPANSION EAT EC EDB ELEV ELEC ESP ETR EWB EWC EWT EXH EX ENTERING AIR TEMPERATURE ELECTRICAL CONTRACTOR (DIV 15) ENTERING DRY BULB ELEVATION ELECTRICAL EXTERNAL STATIC PRESSURE EXISTING TO REMAIN ENTERING WET BULB ELECTRICAL WATER COOLER ENTERING WATER TEMPERATURE EXHAUST EXIST EXISTING FA FACP FCO FLA FLEX FP FPM FT °F FIRE ALARM FIRE ALARM CONTROL PANEL FLOOR CLEANOUT FULL LOAD AMPS FLEXIBLE FIRE PROTECTION FEET PER MINUTE FOOT, FEET DEGREES FAHRENHEIT G GA GAL GC GFI GPM GRND GAS GAUGE GALLON GENERAL CONTRACTOR GFIC GROUND FAULT INTERRUPTER GALLONS PER MINUTE GROUND H HORIZ HP HTG HTR HVAC HW HEIGHT HORIZONTAL HORSEPOWER, HEAT PUMP HEATING HEATER HEATING, VENTILATING & A/C HOT WATER ID IE INSIDE DIAMETER INVERT ELEVATION KVA KW KWH INCH, INCHES WC INCHES OF WATER COLUMN O/H OA OBD OC OD KILOVOLT-AMPS KILOWATTS KILOWATT-HOUR OSHA L LAT LBS, # LDB LF LP LRA LTG LWB LWT INTERNALLY LINED LEAVING AIR TEMPERATURE POUNDS LEAVING DRY BULB LINEAR FEET LOW PRESSURE LOCKED ROTOR AMPS LIGHTING LEAVING WET BULB LEAVING WATER TEMPERATURE MAX MBTU MBH MC MAXIMUM 1000 BTU PER HOUR 1000 BTU PER HOUR MECHANICAL CONTRACTOR (DIV 15) MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER MOTORIZED DAMPER MECHANICAL MANUFACTURER MINIMUM MAXIMUM OVER CURRENT PROTECTION MEDIUM PRESSURE MOUNTED MAKE-UP AIR MCA MCB MD MECH MFR MIN MOCP MP MTD MUA N/A NEC NEMA NFPA NIC NTS NOT APPLICABLE NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MFR'S ASSOC. NATIONAL FIRE PROTECTION ASSOC. NOT IN CONTRACT NOT TO SCALE OVERHEAD OUTSIDE AIR (VENTILATION AIR) OPPOSED BLADE DAMPER ON CENTER OVERFLOW DRAINAGE, OUTSIDE DIAMETER OCCUPATIONAL SAFETY &HEALTH ADMIN. PD PF PH PLBG PNL PSI PRV PVC PRESSURE DROP POWER FACTOR PHASE PLUMBING PANEL POUNDS PER SQUARE INCH PRESSURE RELIEF VALVE POLYVINYL CHLORIDE RA RCP RD RE: RECIRC REL REQD REV REX RH RLA RPM RWC RETURN AIR REFLECTED CEILING PLAN, ROOF DRAIN REFERENCE, REFER TO RECIRCULATE RELOCATED REQUIRED REVISION, REVISE REMOVE EXISTING RELATIVE HUMIDITY RUNNING LOAD AMPS REVOLUTIONS PER MINUTE RAIN WATER CONDUCTOR SA SAN SD SF SMACNA SUPPLY AIR SANITARY SMOKE DETECTOR SQUARE FEET, SQUARE FOOT SHEET METAL & A/C CONT NAT'L ASSOC. STATIC PRESSURE SPECIFICATION STANDARD SP SPEC STD TE THRU TP TSP TSTAT TYP TENANT EXHAUST (TOILET) THROUGH TOTAL PRESSURE TOTAL STATIC PRESSURE THERMOSTAT TYPICAL CONSULTANT PROJECT # 150343 U/F U/G U/S UL UON UNDERFLOOR UNDERGROUND UNDERSLAB UNDERWRITERS LABORATORIES, INC. UNLESS OTHERWISE NOTED V VA VAV VD VERT VTR VOLT, VENT VOLT-AMPERE, VALVE VARIABLE AIR VOLUME VOLUME DAMPER VERTICAL VENT THROUGH ROOF W W/ W/O WB WC WATT, WIDTH WITH WITHOUT WET BULB WATER COLUMN RECTANGULAR DUCTWORK F A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com TX Registration Number: #F-9566 SEAL ROUND DUCTWORK 2" MINIMUM COLLAR RECTANGULAR DUCTWORK ROUND DUCTWORK E AT 45° LATERAL FITTING RECTANGULAR TO ROUND "BUCKLEY FITTING" LAYOUT: M-501 SPLIT BRANCH DUCT HEIGHT DIMENSION 2" LESS THAN MAIN DUCT HEIGHT DIMENSION D D7 NOT USED D11 SCALE: C DUCT BRANCH TAKE-OFF DETAIL MAX. 12" TO BRANCH CONNECTION VANES PRE-ASSEMBLED ON RUNNER PLATES (TYP.) GALVANIZED SHEET METAL DUCT USE GALVANIZED VANES FOR GALVANIZED OR ALUMINUM DUCTS (TYP.) GALVANIZED ELBOW PLATE SAME GAUGE AS DUCT (TYP.) 9" P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\M-501_06078.dwg PLOTTED: 7/16/2015 - 4:03 PM RECTANGULAR TO RETANGULAR 90° COMBINATION TEE WITH OVAL TO ROUND TAP (IF BRANCH FLOW IS 2/3 OF THRU FLOW) SCALE: USER: JGRAY LA PLAZA MALL ABV A/C IN IN METAL STRAP CLAMP (TYPICAL) 2 PLACES SUNGLASS HUT LA PLAZA MALL INSULATED FLEXIBLE CONNECTION. (MAX. 5'-0") IN VERTICAL ONLY. IF GRILL IS TO BE USED AS LIFT OUT GRILL, MIN. 3'-0". VOLUME DAMPER B 3-1/4" 1-1/2" DUCT SIZE OVER 36"x36". SQUARE ELBOW WITH TYPE "A" DOUBLE THICKNESS VANES. LOCATE DAMPER IN HARD CEILING APPLICATIONS TO BE ACCESSIBLE FROM FACE OF DIFFUSER DUCT SIZE 36"x36" OR UNDER. 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 SUPPLY AIR DIFFUSER INSULATION WITH FOIL FACING DRAWN BY: CHC REVIEWED BY: JTP SQUARE ELBOW WITH SINGLE THICKNESS VANES. AUTHORIZED FOR: MECHANICAL DETAILS & ABBREVIATIONS A A1 SCALE: NOT USED 1 A7 SCALE: 2 3 4 5 6 TURNING VANE DETAIL 7 8 A11 SCALE: 9 10 DUCT MOUNTING DETAIL 11 12 M-501 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 O. CEILING GRID SYSTEMS SHALL NOT BE USED TO SUPPORT FIRE PROTECTION ITEMS, PIPING, OR ANY E. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF OTHER EQUIPMENT. EACH UTILITY AND THE CEILING GRID SYSTEM SHALL BE A SEPARATE INSTALLATION THIS DESIGN. A. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL A FIRE AND EACH SHALL BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE. WHERE F. PROVIDE AND INSTALL A VALVED TEST CONNECTION IN AN ACCESSIBLE LOCATION FOR THE SPRINKLER PROTECTION SYSTEM, COMPLETE AS INDICATED ON THE DRAWINGS AND AS REQUIRED BY CODE AND INTERFERENCE OCCURS, IN ORDER TO SUPPORT EQUIPMENT OR CEILING GRID SYSTEM, CONTRACTOR SYSTEM AS REQUIRED OR REQUESTED BY THE LANDLORD, LOCAL INSPECTOR, OR INSURANCE AS SPECIFIED HEREIN. MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL NOT BE LOCATED WHERE THEY CARRIER. INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, LIGHT FIXTURES, AND OTHER MECHANICAL OR B. THE GENERAL CONTRACTOR, UNLESS OTHERWISE NOTED IS TO PROVIDE POWER WIRING FOR EACH G. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY LEAKS IN ANY OF THE EQUIPMENT ELECTRICAL ITEMS. ITEM OF ELECTRICAL EQUIPMENT AND MAKE FINAL CONNECTIONS TO MOTORS. INSTALLED. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE BY THIS CONTRACTOR AT THIS P. INSTALL ALL SPRINKLER HEADS IN ROOMS IN AN ESTHETIC MANNER. SPRINKLER ARRANGEMENT SHALL C. ALL FINISH PAINTING IS TO BE PERFORMED BY THE GENERAL CONTRACTOR, EXCEPT AS NOTED CONTRACTOR'S EXPENSE. BE PARALLEL AND PERPENDICULAR TO THE BUILDING WALLS. COORDINATE WITH ARCHITECT AND ELSEWHERE. GENERAL CONTRACTOR, AT THIS CONTRACTOR'S EXPENSE, SHALL RESTORE TO ORIGINAL H. PROPERLY COMPLETED AND SIGNED "SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" TENANT. CONDITION ANY PAINTING DEFACED DURING CONSTRUCTION AND AFTER ORIGINAL PAINTING. SHALL BE FURNISHED TO THE LANDLORD, AND AUTHORITIES HAVING JURISDICTION. Q. CONTRACTOR SHALL VERIFY THE LOCATION OF UTILITIES AND NOTE CONDITIONS WHICH WOULD D. ALL WORK SHALL CONFORM TO CODES, RULES, AND REGULATIONS: AFFECT THE WORK. ALL DISCREPANCIES SHALL THEN BE REPORTED TO THE LANDLORD'S TENANT 21 05 30 SPRINKLER PIPING SPECIALTIES 1. NATIONAL ELECTRIC CODE. COORDINATOR PRIOR TO THE BID AWARD. 21 05 00 FIRE PROTECTION GENERAL PROVISIONS J H 3. CODE FOR SAFETY TO LIFE FROM FIRE IN BUILDINGS AND STRUCTURES, NFPA 101. 4. FEDERAL OCCUPATIONAL SAFETY AND HEALTH STANDARDS. 5. STATE MECHANICAL CODE. 6. STATE BUILDING CODE 7. STATE INDUSTRIAL COMMISSION REQUIREMENTS. 8. LOCAL BUILDING CODE REQUIREMENTS. 9. BUILDING INSURING AGENCY REQUIREMENTS. 10. STATE PLUMBING CODE. 11. NFPA. E. ALL PERMITS REQUIRED BY LAWS, ORDINANCES AND BUILDING CODES HAVING JURISDICTION SHALL BE OBTAINED AT THE PROPER TIME BY AND AT THE EXPENSE OF THIS CONTRACTOR. F. CONTRACTOR SHALL OBTAIN ALL INSPECTIONS REQUIRED BY ALL LAWS, ORDINANCES AND PUBLIC AUTHORITY HAVING JURISDICTION AND SHALL OBTAIN CERTIFICATES OF SUCH INSPECTIONS AND SUBMIT SAME TO THE ARCHITECT AND SHALL PAY ALL FEES, CHARGES, ASSESSMENTS AND OTHER EXPENSES IN CONNECTION THEREWITH. G. THE MATERIALS AND EQUIPMENT INSTALLED IN THE WORK SHALL MEET THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND NO MATERIALS OR EQUIPMENT SHALL BE ORDERED UNTIL REVIEWED BY THE ENGINEER, LANDLORD AND/OR ARCHITECT. H. G I. F STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS, NFPA 90A. R. S. CONTRACTOR TO MAINTAIN ONE SET OF DRAWINGS ON THE JOB TO BE USED STRICTLY FOR RECORDING ANY INSTALLATION DEVIATIONS FROM THE CONTRACT DRAWINGS. T. CONTRACTOR IS RESPONSIBLE FOR DAILY CLEAN-UP AND REMOVAL OF FIRE PROTECTION DEBRIS FROM THE SITE WEEKLY. THE PREMISES SHALL BE KEPT IN A NEAT AND ORDERLY CONDITION. U. CONTRACTOR SHALL REVIEW AND FOLLOW ALL LANDLORD REQUIREMENTS. THE SUBMITTING OF A BID AUTOMATICALLY IMPLIES THAT THESE REQUIREMENTS HAVE BEEN REVIEWED AND ARE IN THE BID PRICE AND INFORM LANDLORD IN ADVANCE OF ANY DOWN TIME. V. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. A. PROVIDE INSTRUCTION TO LANDLORD'S OPERATING PERSONNEL AS NECESSARY, SHOWING LOCATIONS AND PROPER OPERATION OF MAJOR ITEMS OF EQUIPMENT AND SYSTEM COMPONENTS AND B. REFERRING TO THE OPERATING INSTRUCTION MANUAL DESCRIBED BELOW AS A GUIDE. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING LANDLORD. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT. K. ANY REFERENCE TO TENANT OR TENANT'S CONSTRUCTION MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO LUXOTTICA GROUP. L. REFER TO RESPONSIBILITY SCHEDULE ON SHEET G-002 FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. C. M. DEMOLITION 1. N. E LAYOUT: M-701 P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\M-701_06078.dwg PLOTTED: 7/16/2015 - 4:03 PM USER: JGRAY D CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND LABOR PROVIDED UNDER THIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT NO ADDITIONAL COST ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT DISCOVERED WITHIN 12 MONTHS FROM THE DATE OF CERTIFICATE OF OCCUPANCY. THIS GUARANTEE SHALL EXTEND TO LABOR AND MISCELLANEOUS MATERIALS REQUIRED FOR THE INSTALLATION OF EQUIPMENT. THE CONTRACTOR IS RESPONSIBLE TO VERIFY, COORDINATE AND FOLLOW ALL PROPER HANDLING AND INSTALLATION TECHNIQUES WITH MANUFACTURER(S) IN ORDER TO MAINTAIN MANUFACTURER'S WARRANTY. C B CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT HAZARD CLASSIFICATION, AS WELL AS, THE QUANTITY, SPACING, AND PROTECTED AREA LIMITATION OF SPRINKLER HEADS. CONTRACTOR SHALL FURTHER BE RESPONSIBLE FOR CONFIRMING HIS DETERMINATION WITH THE LANDLORD'S INSURING AGENCY AND THE LOCAL FIRE AUTHORITY HAVING JURISDICTION OVER THE PROJECT. 2 3 1. SPRINKLERS (AS REQUIRED) 2. VALVES (AS REQUIRED) 3. TAMPER SWITCHES (AS REQUIRED) 4. WATER FLOW SWITCHES (AS REQUIRED) 5. HYDRAULIC CALCULATIONS (AS REQUIRED) 6. CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM WHEN SUBMITTED FOR THE ARCHITECT'S REVIEW, SHOP DRAWINGS SHALL BEAR GENERAL CONTRACTOR'S CERTIFICATION THAT THEY HAVE REVIEWED, CHECKED AND APPROVED THE SHOP DRAWINGS, THAT THEY ARE IN HARMONY WITH THE REQUIREMENTS OF THE PROJECT AND WITH THE PROVISIONS OF THE CONTRACT DOCUMENTS AND THAT THEY HAVE VERIFIED ALL FIELD MEASUREMENTS AND CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBER AND FIELD MEASUREMENTS AND SIMILAR DATA. CONTRACTOR SHALL ALSO CERTIFY THAT THE WORK REPRESENTED BY THE SHOP DRAWINGS IS RECOMMENDED BY CONTRACTOR AND THE CONTRACTOR'S GUARANTEE WILL FULLY APPLY. ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST EXAMINE THE SITE AND ALL CONDITIONS THEREIN. ALL PROPOSALS SHALL TAKE INTO CONSIDERATION ALL SUCH CONDITIONS AS THEY MAY AFFECT THE WORK UNDER THIS CONTRACT. THE SUBMITTING OF A BID AUTOMATICALLY IMPLIES THAT THIS EXAMINATION OF THE SITE HAS BEEN DONE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TESTING OF SPRINKLER PIPING PER NFPA. B. TEST SPRINKLER PIPING WITH A HYDROSTATIC TEST AT 200 PSI FOR 2 HOURS WITH NO VISIBLE LEAKAGE. C. TEST ALARMS, FLOW SWITCHES, AND TAMPERPROOF SWITCHES AND ADJUST AS NECESSARY. D. CONTRACTOR AND LANDLORD SHALL SIGN CERTIFICATES, INDICATING WITNESSING OF ALL TESTS REQUIRED BY NFPA-13 FOR ABOVE GROUND PIPING. E. REPAIR ANY LEAKING JOINTS AND REPAIR ANY DAMAGE TO THE FACILITY THAT THE LEAK MAY HAVE CREATED. CLEAN, PAINT, OR REPLACE ANY DAMAGED COVERINGS AS REQUIRED TO MEET THE LANDLORD'S APPROVAL. B. ALL HANGER ASSEMBLIES SHALL BE UL AND FM APPROVED. C. HANGER SPACING SHALL MEET NFPA-13 MINIMUM REQUIREMENTS. 21 05 26 INTERIOR PIPE TUBE AND FITTINGS AND SPRINKLER HEADS A. SPRINKLER HEADS: 1. PROVIDE AN NFPA-13 APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM IN BUILDING. SYSTEM SHALL BE APPROVED BY THE LOCAL AND STATE FIRE MARSHAL'S OFFICE. ALL SPRINKLER HEADS SHALL BE NEW, QUICK RESPONSE, U.L. LISTED, F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY STAR, RELIABLE, SIMPLEX-GRINNELL, VIKING, OR CENTRAL SPRINKLER CO. 2. F. THE INSTALLING CONTRACTOR SHALL BE LICENSED AND CERTIFIED IN THE INSTALLATION OF AUTOMATIC SPRINKLER SYSTEMS IN THIS STATE. ALL SPRINKLER HEADS SHALL BE RATED FOR 165°F UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. 3. G. CONTRACTOR SHALL OBTAIN AND PAY FOR ANY INSPECTION FEES, CHARGES, AND ANY OTHER GOVERNMENTAL FEES APPLICABLE. "SALES" AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE TO MATCH CEILING. 4. H. CONTRACTOR SHALL FILE ALL NECESSARY DRAWINGS, SPECIFICATIONS, CONTRACTOR'S MATERIAL AND TEST CERTIFICATES. "NON-SALES" AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE TO MATCH CEILING. 5. I. CONTRACTOR SHALL OBTAIN A CERTIFICATE OF INSPECTION AND APPROVAL AND SUBMIT TO THE ARCHITECT PRIOR TO THE REQUEST FOR FINAL PAYMENT. "NON-SALES" NO CEILING SPRINKLER HEADS ARE TO BE CHROME UPRIGHT, ADJUSTABLE SCREW TYPE. 6. J. CONTRACTOR SHALL PROVIDE ALL PRODUCTS AND LABOR REQUIRED TO COMPLETE THE INSTALLATION B. OF ALL FIRE PROTECTION SPRINKLER SYSTEMS. "MALL BULKHEAD" AREA SPRINKLER HEADS ARE TO BE FULLY CONCEALED ADJUSTABLE SCREW TYPE WITH WHITE COVER PLATE TO MATCH CEILING. K. FIRE PROTECTION PIPING AND EQUIPMENT LAYOUT SHALL BE COORDINATED WITH ALL EQUIPMENT, BOTH KNOWN AND UNKNOWN, AND EQUIPMENT INCLUDED UNDER OTHER DIVISIONS OF THE SPECIFICATIONS. L. ALL FIRE PROTECTION PIPING SHALL BE INSTALLED AS CONCEALED WORK, WHERE APPLICABLE. D. WHERE APPLICABLE, LOCATE SPRINKLER HEADS IN CENTER OF CEILING TILE, USE ARMOVER ON ALL SPRINKLER BRANCH LINES TO ACCOMPLISH EXACT LOCATION OF HEAD. E. SCHEDULE 40, BLACK STEEL PIPE, ASTM A-53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI B-36-10-70 FOR WROUGHT STEEL PIPE. 2. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. M. THE ARCHITECT RESERVES THE RIGHT TO CHANGE THE LOCATION OF ANY SPRINKLER HEAD DURING THE SUBMITTAL PROCESS EVEN IF THE MOVE SHOULD REQUIRE ADDITIONAL HEADS. 3. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. N. 4. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. 5. HANGERS SHALL COMPLY WITH LANDLORD AND CODE REQUIREMENTS. FILL ANNULAR SPACE BETWEEN SLEEVE AND PIPE OR INSULATION ON ALL PENETRATIONS THROUGH FIRE RATED WALLS. FIRESTOPPING MATERIALS SHALL BE UL CLASSIFIED AND MEET THE REQUIREMENTS OF ASTM. THE METHOD OF INSULATION SHALL CONFORM TO UL FIRE RESISTANCE DIRECTORY. 4 5 6 7 SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM PIPING: 1. A 1 SEAL F. NOTIFY THE LANDLORD IN WRITING FOR ANY SCHEDULING OF ANY TESTS OR DOWNTIME OF THE MODIFY THE EXISTING SPRINKLER SYSTEM AND FURNISH ALL MATERIALS, LABOR, TOOLS, EXISTING SPRINKLER SYSTEM. ADMINISTRATION, TRANSPORTATION, INCIDENTALS AND APPURTENANCES WHICH ARE REQUIRED TO COMPLETE IN EVERY DETAIL AND LEAVE IN WORKING ORDER ALL ITEMS OF WORK CALLED FOR HEREIN 21 05 25 SUPPORTS, ANCHORS, AND SEALS OR SHOWN ON THE ACCOMPANYING DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR CONNECTING TO A. UL LISTED HANGERS, BEAM CLAMPS, HANGER RODS, PIPE ATTACHMENTS, AND PIPE SLEEVES SHALL THE LANDLORD'S FIRE ALARM SYSTEM. COORDINATE WITH LANDLORD'S APPROVED FIRE ALARM AND BE PER SP-58. EQUAL MANUFACTURERS TO BE SIMPLEX GRINNELL, B-LINE, OR MICHIGAN HANGERS. SPRINKLER CONTRACTORS. B. INCLUDE ANY MINOR ITEMS OF WORK NECESSARY TO PROVIDE A COMPLETE AND FULLY OPERATIVE FIRE PROTECTION SYSTEM. C. THIS CONTRACTOR IS TO BECOME INFORMED OF THE EXACT DIMENSIONS OF FINISHED WORK WHERE PIPES, DUCTS AND EQUIPMENT ARE TO BE PLACED AND WILL ARRANGE THE WORK ACCORDINGLY, ASSUMING ALL RESPONSIBILITY FOR PROPER LOCATION AND COORDINATION OF THE WORK. Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com TX Registration Number: #F-9566 CONTRACTOR SHALL SUBMIT FOR THE ARCHITECT'S AND LANDLORD REVIEW SIX (6) COMPLETE COPIES OF THE CATALOG DATA AND/OR SHOP DRAWINGS FOR THE LISTED ITEMS OF EQUIPMENT AND ALL COMPONENTS TO BE USED IN THE WORK, INCLUDING SPECIFIC PERFORMANCE DATA, MATERIAL DESCRIPTION, RATING, CAPACITY, WORKING PRESSURE, MATERIAL GAUGE OF THICKNESS, BRAND NAME, CATALOG NUMBER AND GENERAL TYPE. THE SUBMISSION SHALL BE COMPILED BY CONTRACTOR AND REVIEWED BY ENGINEER BEFORE ANY OF THE EQUIPMENT IS ORDERED. A. 21 05 13 COMMON WORK RESULTS FOR FIRE SUPPRESSION A. B. PROVIDE ALL NECESSARY DRAINS. COORDINATE THE EXACT LOCATION WITH THE ARCHITECT AND LANDLORD PRIOR TO ANY INSTALLATION. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION AND REMOVAL OF EXISTING WORK. FIELD VERIFY AND COORDINATE ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT 21 05 19 TESTS AND PROTECT EQUIPMENT TO REMAIN DURING CONSTRUCTION. WARRANTY AND GUARANTEE 1. A. 21 05 16 SHOP DRAWINGS CATALOG DATA FOR EQUIPMENT REVIEWED BY THE ARCHITECT SHALL NOT SUPERSEDE THE ENGINEER'S CONTRACT DOCUMENTS. THE REVIEW OF THE ENGINEER SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS, PROVIDING PROPER CLEARANCE, FABRICATION PROCESS AND COORDINATION WITH OTHER TRADES. J. INSTALLATION WILL NOT BE CONSIDERED COMPLETE UNLESS AND UNTIL WRITTEN ACCEPTANCE IS RECEIVED FROM THE STATE FIRE MARSHAL AND THE LANDLORD'S INSURING AGENCY. LA PLAZA MALL 2. CONSULTANT PROJECT # 150343 AT K A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 C. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN "SALES" AREAS AND 100 SQ. FT. IN "STOCK" AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. D. ALL SPRINKLER LINES SHALL BE INSTALLED CONCEALED, AVOIDING INTERFERENCE WITH OTHER TRADES. 8 9 10 SGH STORE #: 6078 DRAWN BY: CHC REVIEWED BY: JTP AUTHORIZED FOR: FIRE PROTECTION SPECIFICATIONS M-701 11 12 13 14 3 4 5 6 7 K PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL A HEATING, VENTILATING, AIR CONDITIONING SYSTEM, COMPLETE AS INDICATED ON THE DRAWINGS, AS REQUIRED BY CODE AND AS SPECIFIED HEREIN. B. THE GENERAL CONTRACTOR, UNLESS OTHERWISE NOTED IS TO PROVIDE POWER WIRING FOR EACH ITEM OF ELECTRICAL EQUIPMENT AND MAKE FINAL CONNECTIONS TO MOTORS. C. ALL FINISH PAINTING IS TO BE PERFORMED BY THE GENERAL CONTRACTOR, EXCEPT AS NOTED ELSEWHERE. GENERAL CONTRACTOR, AT THIS CONTRACTOR'S EXPENSE, SHALL RESTORE TO ORIGINAL CONDITION ANY PAINTING DEFACED DURING CONSTRUCTION AND AFTER ORIGINAL PAINTING. D. J H ALL WORK SHALL CONFORM TO CODES, RULES, AND REGULATIONS: 1. NATIONAL ELECTRIC CODE. 2. STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS, NFPA 90A. 3. CODE FOR SAFETY TO LIFE FROM FIRE IN BUILDINGS AND STRUCTURES, NFPA 101. 4. FEDERAL OCCUPATIONAL SAFETY AND HEALTH STANDARDS. 5. STATE MECHANICAL CODE. 6. STATE BUILDING CODE 7. STATE INDUSTRIAL COMMISSION REQUIREMENTS. 8. LOCAL BUILDING CODE REQUIREMENTS. 9. BUILDING INSURING AGENCY REQUIREMENTS. 10. STATE PLUMBING CODE. 11. NFPA. 23 05 01 HVAC BASIC MATERIALS AND METHOD F. CONTRACTOR SHALL OBTAIN ALL INSPECTIONS REQUIRED BY ALL LAWS, ORDINANCES AND PUBLIC AUTHORITY HAVING JURISDICTION AND SHALL OBTAIN CERTIFICATES OF SUCH INSPECTIONS AND SUBMIT SAME TO THE ARCHITECT AND SHALL PAY ALL FEES, CHARGES, ASSESSMENTS AND OTHER EXPENSES IN CONNECTION THEREWITH. C. ALL DUCTWORK SHALL BE PLACED SO AS TO AVOID INTERFERENCE WITH PLUMBING PIPES, ELECTRIC CONDUITS OR PIPES OF OTHER CONTRACTORS. D. ALL DUCTWORK MUST BE PROVIDED WITH SUFFICIENT DISTANCE FROM WALLS, PIPES AND OTHER OBSTACLES TO PERMIT THE APPLICATION OF FULL THICKNESS OF INSULATION SPECIFIED. E. THIS CONTRACTOR SHALL PERFORM AN ACCURATE AND COMPLETE BALANCE OF AIR SYSTEMS AS PART OF THIS CONTRACT, WHICH SHALL BE COMPLETED BEFORE FINAL ACCEPTANCE OF THE WORK OF THIS CONTRACT. AIR BALANCE SHALL BE SUBCONTRACTED TO A CERTIFIED MEMBER OF ASSOCIATED AIR BALANCE COUNCIL. F. VIBRATION ISOLATION DEVICES 1. 4. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. J. CATALOG DATA FOR EQUIPMENT REVIEWED BY THE ARCHITECT SHALL NOT SUPERSEDE THE ENGINEER'S CONTRACT DOCUMENTS. THE REVIEW OF THE ENGINEER SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS, PROVIDING PROPER CLEARANCE, FABRICATION PROCESS AND COORDINATION WITH OTHER TRADES. 5. CONSULT MANUFACTURER FOR APPLICATION DATA. K. WHEN SUBMITTED FOR THE ARCHITECT'S REVIEW, SHOP DRAWINGS SHALL BEAR THE CONTRACTOR'S CERTIFICATION THAT THE CONTRACTOR HAS REVIEWED, CHECKED AND APPROVED THE SHOP DRAWINGS, THAT THEY ARE IN HARMONY WITH THE REQUIREMENTS OF THE PROJECT AND WITH THE PROVISIONS OF THE CONTRACT DOCUMENTS AND THAT THE CONTRACTOR HAS VERIFIED ALL FIELD MEASUREMENTS AND CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBERS AND SIMILAR DATA. CONTRACTOR SHALL ALSO CERTIFY THAT THE WORK REPRESENTED BY THE SHOP DRAWINGS IS RECOMMENDED BY THE CONTRACTOR AND THE CONTRACTOR'S GUARANTEE WILL FULLY APPLY. L. ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST EXAMINE THE SITE AND ALL CONDITIONS THEREIN. ALL PROPOSALS SHALL TAKE INTO CONSIDERATION ALL SUCH CONDITIONS AS MAY AFFECT THE WORK UNDER THIS CONTRACT. THE SUBMITTING OF A BID AUTOMATICALLY IMPLIES THAT THIS EXAMINATION OF SITE HAS BEEN DONE. LAYOUT: M-702 P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\M-702_06078.dwg PLOTTED: 7/16/2015 - 4:04 PM USER: JGRAY D P. PROVIDE INSTRUCTION TO LANDLORD'S OPERATING PERSONNEL AS NECESSARY, SHOWING LOCATIONS AND PROPER OPERATION OF MAJOR ITEMS OF EQUIPMENT AND SYSTEM COMPONENTS AND REFERRING TO THE OPERATING INSTRUCTION MANUAL DESCRIBED BELOW AS A GUIDE. R. D. GENERAL CONTRACTOR SHALL REVIEW AIR BALANCE REPORT PRIOR TO SUBMISSION OF REPORT TO ENGINEER AND ARCHITECT. IF ENGINEER OR ARCHITECT REVIEW THE AIR BALANCE REPORT MULTIPLE TIMES DUE TO THE CONTRACTOR NOT FOLLOWING THESE GUIDELINES OR SENDING A PRELIMINARY REPORT FOR REVIEW IN LIEU OF THE FINAL REPORT, THE CONTRACTOR WILL BE BACKCHARGED FOR ALL REVIEWS BEYOND THE FIRST. VERIFY CONTROLS DURING BALANCING, INCLUDING HUMIDITY CONTROLS WHERE APPLICABLE. LIST OF MAJOR EQUIPMENT USED IN PROJECT ACCOMPANIED BY CONTRACTOR PURCHASE ORDER NUMBERS AND SUPPLIERS NAMES AND ADDRESSES. 4. ONE COPY OF EACH SHOP DRAWING GROUPED BY TYPES OF EQUIPMENT (I.E., ROOFTOP UNITS, FANS, ETC.) 5. SECTION FOR EACH SYSTEM INCLUDING: C. EXPOSED ROUND AND RECTANGULAR DUCTWORK SHALL HAVE NO INSULATION. a. BRIEF DESCRIPTION OF SYSTEM OPERATION WITH LOCATION OF MAJOR COMPONENTS. D. b. HVAC SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS AND SCHEMATICS. SUBMIT A COMPLETED COPY TITLED "HVAC OPERATING INSTRUCTION MANUAL" ON THE BINDING EDGE OF BINDER TO ARCHITECT FOR APPROVAL. AFTER ARCHITECT'S REVIEW AND ANY CORRECTIONS REQUIRED ARE COMPLETED, SUBMIT A COPY OF THE MANUAL TO THE LANDLORD. ANY REFERENCE TO TENANT OR TENANT CONSTRUCTION MANAGER, OR FURNISHED BY ANY OF THE ABOVE, REFERS TO LUXOTTICA. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO TENANT CONSTRUCTION MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR TENANT CONSTRUCTION MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF THE CONTRACTOR AND THE SUB-CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. DEMOLITION 1. 4 C. AFTER CORRECTING BALANCE OF ALL AIR SYSTEMS TO WITHIN 10% OF DESIGNED VALUES, SUBMIT FINAL AIR BALANCE REPORTS TO ARCHITECT, ENGINEER, AND LUXXOTICA. FINAL BALANCE REPORT MUST INDICATE AIR VALUES WITHIN 10% OF DESIGN, OR MUST STATE THE REASON THAT THE APPROPRIATE BALANCE COULD NOT BE ACHIEVED. 3. 2. 3 B. ALL AIR DISTRIBUTION SYSTEMS ARE TO BE BALANCED IN ACCORDANCE WITH GENERALLY ACCEPTED ENGINEERING STANDARDS BY A NEBB CERTIFIED VENDOR. DUCTED AIR RATES ARE TO BE MEASURED AND ADJUSTED TO DELIVER FINAL FLOW RATES WITHIN 10% OF DESIGN RATES. GENERAL CONTRACTOR TO DO ALL ADJUSTMENTS REQUIRED TO BALANCE THE SYSTEM WITHIN THE DESIGN PARAMETERS. UNITS RPMS ARE TO BE ADJUSTED FIRST TO GET THE UNIT TO THE LOWEST RPMS TO DELIVER THE REQUIRED CFM TO THE DIFFUSERS, THEN THE DAMPERS TO THE DIFFUSERS ARE TO BE ADJUSTED TO BALANCE THE SYSTEM. GENERAL CONTRACTOR IS TO PROVIDE ALL LABOR AND MATERIALS REQUIRED TO BALANCE THE SYSTEM. INDEX B 2 A. 2. 1. U. 23 05 93 TESTING, ADJUSTING AND BALANCING FOR HVAC TITLE PAGE: TITLE OF JOB, LANDLORD/TENANT, ADDRESS, DATE, SUBMISSION, CONTRACTOR AND ENGINEER. S. REFER TO RESPONSIBILITY SCHEDULE ON SHEET G-002 FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. T. 12 13 14 J. FLEXIBLE SUPPLY AIR DUCTWORK WITH 1" THICK FIBERGLASS BLANKET INSULATION WITH METALIZED FILM VAPOR BARRIER OUTER JACKET. FLEXIBLE DUCT IN RETURN AIR PLENUM TO BE CLEARLY LABELED "CLASS 1" EVERY FOUR FEET. FLEXIBLE DUCT LENGTH MAY NOT EXCEED FIVE FEET. INSULATION SHALL HAVE MIN. INSTALLED R-VALUE OF 4.2. K. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED. L. DUCT CONSTRUCTION SHALL BE AS FOLLOWS: 1. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT ALL LOW PRESSURE DUCT IN ACCORDANCE WITH THE LATEST EDITION OF SMACNA STANDARDS WITH THE FOLLOWING PRESSURE CLASSIFICATIONS: a. SUPPLY DUCTS: 2" W.G. POSITIVE. b. RETURN AND EXHAUST DUCTS: 2" W.G. NEGATIVE. 2. SEAL ALL LOW PRESSURE DUCTS PER SMACNA CLASS B AND ALL MEDIUM PRESSURE DUCTS TO SMACNA CLASS A. 3. REGARDLESS OF ABOVE DUCT CONSTRUCTION AND SEALANT PRESSURE CLASSIFICATIONS, MAXIMUM DUCT AIR LEAKAGE WILL NOT EXCEED 5% AS REQUIRED FOR FINAL AIR BALANCE APPROVAL. 6 7 CONSULTANT PROJECT # 150343 Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com TX Registration Number: #F-9566 SEAL M. ROUND DUCTWORK SHALL BE GALVANIZED STEEL WITH SPIRAL LOCK SEAM CONSTRUCTION FOR ALL SIZES 12" DIAMETER AND LARGER. ROUND DUCTWORK SIZES 10" DIAMETER AND SMALLER MAY BE SNAP-LOCK CONSTRUCTION. ALL SNAP-LOCK SEAMS SHALL BE SEALED AS DESCRIBED IN THESE SPECIFICATIONS. ROUND FITTINGS SHALL BE GALVANIZED STEEL WITH SPOT WELDED AND BONDED CONSTRUCTION. DUCTWORK SHALL BE AS MANUFACTURED BY UNITED MCGILL, SEMCO, OR APPROVED EQUAL. N. ALL JOINTS AND SEAMS SHALL BE SEALED WITH 2" WIDE, GLASS- FIBER FABRIC REINFORCED TAPE. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. LIQUID SEALANTS BY UNITED MCGILL CORP., DOW CORNING, MIRACLE ADHESIVES AND SUREBOND INC. WILL BE ACCEPTED IN LIEU OF TAPE. 23 07 00 HVAC INSULATION A. DUCT INSULATION AND APPURTENANCES SHALL HAVE A FLAME SPREAD RATING NOT EXCEEDING TWENTY-FIVE (25) AND A SMOKE DEVELOPED RATING NOT EXCEEDING FIFTY (50). B. RECTANGULAR AND ROUND SUPPLY, RETURN, AND OUTSIDE AIR DUCTWORK CONCEALED FROM VIEW SHALL HAVE FLEXIBLE FIBERGLASS DUCT WRAP LAMINATED TO FOIL REINFORCED KRAFT VAPOR BARRIER FACING WITH 2" STAPLING FLANGE AND MIN. INSTALLED R-VALUE OF 4.2. OR AS REQUIRED BY LOCAL CODES. OWENS-CORNING COMMERCIAL GRADE FIBERGLASS DUCT WRAP TYPE 100. ALL DUCTWORK IN UNCONDITIONED SPACES SHALL HAVE INSULATION DUCT WRAP WITH A MINIMUM INSTALLED R-VALUE OF 5.0. CONDITIONED SPACES SHALL HAVE INSULATION DUCT WRAP WITH A MINIMUM INSTALLED R-VALUE OF 4.2. IN ALL CASES THE INSULATING VALUES SHALL BE IN ACCORDANCE WITH LOCAL CODES. E. INSULATION SHALL NOT BE APPLIED UNTIL THE GENERAL CONSTRUCTION HAS PROGRESSED SUFFICIENTLY TO INSURE AGAINST PHYSICAL OR MOISTURE DAMAGE TO THE INSULATION. ALL INSULATION DAMAGED THROUGH FAILURE TO OBSERVE THIS DIRECTIVE SHALL BE REPLACED AT THIS CONTRACTOR'S EXPENSE. F. HANGER RODS MUST BE PERPENDICULAR TO DUCTWORK BEFORE INSULATION IS INSTALLED. 23 33 00 DAMPERS A. RECTANGULAR DUCT GALVANIZED STEEL MANUAL BALANCE AND MOTORIZED DAMPER 6" WIDE 16 GAUGE OPPOSED BLADES, CHANNEL FRAME WITH BRACED CORNERS, CONCEALED LINKAGE, TEFLON FILLED BEARINGS, 3/8" DIAMETER AXLE, 6" LONG CONTROL SHAFT. MOTORIZED DAMPER TO HAVE REPLACEABLE BUTYL RUBBER SEALS INSTALLED ALONG THE TOP, BOTTOM AND SIDES OF THE FRAME, AS WELL AS, ALONG ALL SIDES OF EACH BLADE. B. ROUND GALVANIZED STEEL MANUAL BALANCE DAMPER WITH SINGLE 16 GAUGE BLADE, CHANNEL FRAME, STAINLESS STEEL SLEEVE BEARINGS PRESSED INTO FRAME, 3/8" DIAMETER AXLE EXTENDED 6" FOR CONTROL SHAFT, BLADE STOP. C. EQUIP DAMPERS WITH LOCKING QUADRANTS. D. INSTALL BALANCE DAMPERS WHERE SHOWN ON THE DRAWINGS AND ELSEWHERE AS NECESSARY TO OBTAIN PROPER SYSTEM BALANCE. E. CHECK DAMPERS FOR PROPER OPERATION BEFORE AND AFTER INSTALLATION. F. DAMPERS SHALL BE RUSKIN. EQUAL PRODUCT BY AMERICAN WARMING AND VENTILATING, LOUVERS AND DAMPERS, OR PREFCO MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. 23 37 13 AIR DISTRIBUTION DEVICES A. SQUARE CEILING SUPPLY AIR DIFFUSER - STEEL SQUARE CEILING DIFFUSER, CONCENTRIC CONE FACE, ROUND NECK, VOLUME CONTROL DAMPER, TITUS MODEL TMS. B. CEILING RETURN AIR GRILLE - STEEL CEILING GRILLE, TITUS MODEL 355RL. C. FINISHES - FURNISH ALL AIR DISTRIBUTION DEVICES WITH PRIME COATED AND WHITE BAKED ENAMEL FINISH COAT UNLESS SPECIFIED OTHERWISE. D. COORDINATE AIR DISTRIBUTION DEVICE LOCATIONS WITH ALL AFFECTED CONTRACTORS BEFORE INSTALLING DUCTWORK. SIGNIFICANT DEVIATIONS IN LOCATIONS FROM THOSE SHOWN ON THE DRAWINGS MUST BE APPROVED BY ARCHITECT BEFORE INSTALLATION. E. SUSPEND CEILING AIR DEVICES FROM STRUCTURE ON WIRE HANGERS OR FROM RIGID DUCTWORK. CEILING MUST NOT BE USED TO SUPPORT AIR DISTRIBUTION DEVICES. F. SECURELY FASTEN SIDE WALL AIR DEVICES TO RIGID DUCTWORK OR STRUCTURE. G. AIR DISTRIBUTION DEVICES FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR SHALL BE TITUS OR EQUAL TO MODEL SHOWN ON SHEET M-301. G. INSTALL ALL INSULATION ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. H. INSULATION SHALL BE APPLIED OVER FLANGES, JOINTS AND SEAMS IN PIPING AND DUCTWORK. I. ALL JOINTS AND SEAMS IN INSULATION SHALL BE PROPERLY SEALED TO MAINTAIN VAPOR BARRIER INTEGRITY. J. INSULATION SHALL BE OWENS-CORNING. EQUAL PRODUCT BY ARMSTRONG, CERTAINTEED, SCHULLER OR KNAUF MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. SUNGLASS HUT LA PLAZA MALL 23 31 13 HVAC AIR DISTRIBUTION AND RETURN SYSTEMS A. 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM PROVIDE AND INSTALL DUCTWORK AND PLENUMS OF SIZE AND LOCATION AS SHOWN ON DRAWINGS. ALL DUCTS FOR AIR VELOCITIES LESS THAN 2000 FPM AND STATIC PRESSURE IN DUCT 2" OR LESS SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL. THE GAUGE OF STEEL USED IN ALL DUCTS SHALL BE AS FOLLOWS: SGH STORE #: 6078 1. WHERE GREATER RECTANGULAR DIMENSION IS 12" OR LESS USE 26 GAUGE. 2. WHERE GREATER RECTANGULAR DIMENSION IS FROM 12" THROUGH 30" USE 24 GAUGE. DRAWN BY: CHC 3. WHERE GREATER RECTANGULAR DIMENSION IS FROM 31" THROUGH 54" USE 22 GAUGE. REVIEWED BY: JTP 4. WHERE GREATER RECTANGULAR DIMENSION IS FROM 55" THROUGH 84" USE 20 GAUGE. AUTHORIZED FOR: B. TRANSVERSE JOINTS AND BRACING TO CONFORM TO "HVAC DUCT CONSTRUCTION STANDARDS CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION AND REMOVAL OF EXISTING METAL AND FLEXIBLE" (CURRENT SMACNA). WORK. FIELD VERIFY AND COORDINATE ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT C. ALL DUCTS SHALL BE RIGID AND SHALL BE CROSS-BROKEN, PROPERLY STIFFENED WITH SUITABLE AND PROTECT EQUIPMENT TO REMAIN DURING CONSTRUCTION. BRACES, TOES, OR ANGLES TO KEEP THEM TRUE TO SHAPE AND PREVENT BUCKLING. ALL VERTICAL DUCTS SHALL BE OF STRONG ENOUGH CONSTRUCTION TO CARRY 100 LBS. SUSPENDED LOAD FROM HANGERS WITHOUT BUCKLING. SOLDER ALL JOINTS WHERE NECESSARY TO INSURE TIGHT WORK. SEAMS OF ALL DUCTS AND JOINTS SHALL BE HAMMERED TO A SMOOTH SURFACE ON THE INSIDE. 5 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 O. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 1. Q. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING LANDLORD. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT DISTRIBUTION SYSTEM INCLUDING SIZES, AND THE AIR DESIGN FLOW RATES. 1 EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES, ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID "GROUNDING" THE ISOLATOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS PER THE DOCUMENTS PROVIDED BY THE TENANT/CONTRACTOR. O. COMPILE WRITTEN MANUAL OF OPERATING INSTRUCTIONS INCLUDING COPIES OF SHOP DRAWINGS AND A LISTING OF EQUIPMENT SUPPLIERS. ASSEMBLE IN 8-1/2" X 11" HARD BACKED INDEXED BINDER. MATERIAL SHALL BE AS FOLLOWS: A 3. I. N. C VIBRATION ISOLATION DEVICES SHALL BE FURNISHED AND INSTALLED WITH SUPPORTS BETWEEN VIBRATING EQUIPMENT AND THE STRUCTURE (FANS, AIR HANDLERS, ETC.) BY THIS CONTRACTOR. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES, VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 2. THE MATERIALS AND EQUIPMENT INSTALLED IN THE WORK SHALL MEET THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND NO MATERIALS OR EQUIPMENT SHALL BE ORDERED UNTIL REVIEWED BY THE ENGINEER, LANDLORD AND/OR ARCHITECT. M. CONTRACTOR SHALL VERIFY LOCATION OF UTILITIES AND NOTE CONDITIONS WHICH WOULD AFFECT THE WORK. ALL DISCREPANCIES SHALL THEN BE REPORTED PRIOR TO THE BID AWARD. E THIS CONTRACTOR IS TO BECOME INFORMED OF THE EXACT DIMENSIONS OF FINISHED WORK WHERE PIPES, DUCTS AND EQUIPMENT ARE TO BE PLACED AND WILL ARRANGE THE WORK ACCORDINGLY, ASSUMING ALL RESPONSIBILITY FOR PROPER LOCATION AND COORDINATION OF THE WORK. B. IN THE ERECTION OF THE DUCTWORK, SPECIAL CARE SHALL BE USED PROVIDING SUPPORT. ALL PERMITS REQUIRED BY LAWS, ORDINANCES AND BUILDING CODES HAVING JURISDICTION SHALL BE OBTAINED AT THE PROPER TIME BY AND AT THE EXPENSE OF THIS CONTRACTOR. F 11 D. CONSTRUCTION INCLUDING HANGERS AND SUPPORTING SYSTEMS OF ALL DUCTWORK SHALL ALSO ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, TENANT SHALL HAVE AN BE IN ACCORDANCE WITH "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" INDEPENDENT CONTRACTOR INSPECT THE FINISHED INSTALLATION UPON COMPLETION FOR (CURRENT SMACNA). COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR E. FLEXIBLE CONNECTIONS SHALL BE INSTALLED ON THE OUTLET AND INTAKE OF AIR HANDLING UNITS WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT CONTRACTOR UP AND FANS. THESE CONNECTIONS SHALL BE AT LEAST 6" LONG, MADE OF NFPA 90A APPROVED TO PLANS AND SPECIFICATION REQUIREMENTS. FLAMEPROOF FABRIC. W. WARRANTY AND GUARANTEE F. FURNISH AND INSTALL VOLUME CONTROLLER AND EXTRACTOR AT ALL BRANCH TAKEOFFS IN SUPPLY AND RETURN FROM MAIN DUCTS TO ALL BRANCH DUCTS WHERE SHOWN. UNIT SHALL BE OF TWO 1. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND LABOR PROVIDED UNDER THIS GAUGES HEAVIER THAN THE DUCT. CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT NO ADDITIONAL COST ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT DISCOVERED WITHIN 12 MONTHS FROM THE G. PROVIDE MANUAL ADJUSTING LEVER FOR EACH UNIT. UNITS SHALL MOVE FROM FULL OPEN TO DATE OF CERTIFICATE OF OCCUPANCY. THIS GUARANTEE SHALL EXTEND TO LABOR AND FULLY CLOSED POSITION TO CONTROL AIR DIRECTION AND VOLUME. MISCELLANEOUS MATERIALS REQUIRED FOR THE INSTALLATION OF EQUIPMENT FURNISHED H. FURNISH AND INSTALL TURNING VANES IN ALL ELBOWS OF RECTANGULAR DUCTS. THE BLADES TO THROUGH TENANT NATIONAL ACCOUNTS REPRESENTATIVE, BUT SHALL NOT OVERLAP WITH BE HOLLOW-FORMED DOUBLE THICKNESS VANES. WARRANTY PROVIDED BY MANUFACTURER. THE CONTRACTOR IS RESPONSIBLE TO VERIFY, I. INSTALL SUPPLY AND RETURN REGISTERS, GRILLES AND DIFFUSERS AS SHOWN ON THE DRAWINGS COORDINATE AND FOLLOW ALL PROPER HANDLING AND INSTALLATION TECHNIQUES WITH AND SCHEDULE. MANUFACTURER(S) IN ORDER TO MAINTAIN MANUFACTURER'S WARRANTY. A. E. H. 10 1. G. PIPING AND EQUIPMENT LAYOUT IS SCHEMATIC. EXACT LOCATIONS ARE DETERMINED BY STRUCTURAL AND OTHER CONDITIONS. DESIGN OF SYSTEM MAY NOT BE CHANGED. ONLY EXACT LOCATION OF PIPING AND DUCTS MAY BE REVISED TO SUIT CONSTRUCTION CONDITIONS AND AID IN COORDINATION WITH WORK OF OTHER CONTRACTORS. G 9 V. FINAL HVAC INSPECTIONS 23 05 00 GENERAL PROVISIONS FOR HVAC A. 8 LA PLAZA MALL 2 AT 1 8 9 10 11 MECHANICAL SPECIFICATIONS M-702 12 13 14 3 4 5 6 7 8 9 10 11 KEY NOTES 1. 2. K A-16 16 ADJACENT TENANT (N.I.C.) STUB-UP (TYPICAL) A-14 16 STUB-UP (TYPICAL) 3. A-17 A-37/39/41 13 13 4. 14 J ADJACENT TENANT (N.I.C.) H 101 TECH RACK A-13 29 IG V 5 T J 8. 9. c 25 11 3 18 (E)RTU 6 6. 7. 1,IG 5 STOCK ROOM G MALL COMMON AREA (N.I.C.) 4 A-1 A-5 USB CHARGING STATION 5. 13 16 A-18 8 17 (EX.) RTU STUB-UP (TYPICAL) SALES 10. 11. 100 12. 13. 23 TIME CLOCK AND 9 CONTACTORS A-15 14. 15. 16. 13 13 A-7 IG A-23 PANEL 'A' 17. - 10 7 8 A-22 16 PHONE STUB-UP (TYPICAL) 18. STUB-UP (TYPICAL) A-20 ADJACENT TENANT (N.I.C.) 19. 16 20. F PLAN NORTH 21. 22. 23. F1 SCALE: POWER PLAN 24. 25. 26. E 27. 28. 29. 12 LAYOUT: E-101 P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\E-101_06078.dwg PLOTTED: 7/16/2015 - 4:04 PM 14 GENERAL NOTES FURNISH AND INSTALL FLOOR MOUNTED RECEPTACLE. SEE DIMENSION PLAN THIS SHEET FOR LOCATION. FURNISH AND INSTALL FLOOR MOUNTED POWER/DATA COMBINATION. CONTRACTOR SHALL FURNISH AND INSTALL (1) 1-1/4" CONDUIT WITH CAT6 CABLE PULLED BACK TO RACK FOR DATA OUTLET, SEE DIMENSION PLAN THIS SHEET FOR LOCATION. ON DEDICATED 24 HOUR CIRCUIT. REFER TO DETAIL ON SHEET E-501 DETAIL 'A8' CONDUIT FOR CASH REGISTER POWER CIRCUIT. COORDINATE INSTALLATION REQUIREMENTS WITH CONSTRUCTION MANAGER AND MILLWORK CONTRACTOR . CHECK LENGTH OF SCREWS BEFORE ATTACHING OUTLETS TO MILLWORK. VERIFY SCREWS ARE NOT TOO LONG AND WILL NOT DAMAGE OTHER SIDE OF MILLWORK WHEN TIGHTENED. TRENCH AND PATCH FLOOR AS REQUIRED, COORDINATE LOCATION IN FIELD WITH LANDLORD'S REPRESENTATIVE AND OWNER'S FIELD REPRESENTATIVE PRIOR TO ROUGH-IN. PROVIDE 1" CONDUIT FOR POWER BELOW FLOOR. COORDINATE TRENCH LOCATIONS IN FIELD WITH LANDLORD'S REPRESENTATIVE. REPAIR FLOOR TO MATCH EXISTING CONDITIONS. PROVIDE 1-1/4" CONDUIT FOR TELE/DATA BELOW FLOOR. COORDINATE TRENCH LOCATIONS IN FIELD WITH LANDLORD'S REPRESENTATIVE. REPAIR FLOOR TO MATCH EXISTING CONDITIONS. EXTEND CONDUIT FOR TELE/DATA TO TELE/DATA DISTRIBUTION EQUIPMENT. EXTEND CONDUIT TO TELE/DATA DISTRIBUTION EQUIPMENT. FURNISH AND INSTALL 2'X4' TELEPHONE BOARD WITH SURFACE MOUNTED QUAD RECEPTACLE. EXTEND TELEPHONE SERVICE TO BOARD AND TERMINATE WITH A66 BLOCK. REFER TO ELEVATION SHEET A-502 FOR MORE INFOMATION. FURNISH AND INSTALL TIME CLOCK AND CONTACTORS REFER TO ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION. SEE LIGHTING CONTROL DETAIL ON E-501. ELECTRICAL DISTRIBUTION EQUIPMENT. SEE ONE LINE DIAGRAM ON SHEET E-601. FURNISH AND INSTALL (1) DUPLEX RECEPTACLE ON DEDICATED CIRCUIT MOUNTED AT 2'-6" A.F.F. (TO CENTER OF DEVICE) FOR FRAME WARMER. RECEPTACLE MOUNTED ON CEILING FOR SHOW WINDOW AS REQUIRED BY N.E.C. FURNISH AND INSTALL RECEPTACLE FOR POWER OF DISPLAY CASES BELOW BASE OF MILLWORK SO CORDS AND RECEPTACLE ARE CONCEALED BEHIND FIXTURES. COORDINATE EXACT LOCATION WITH MILLWORK VENDOR. MECHANICAL EQUIPMENT: PROVIDE FEEDERS AND DISCONNECTS PER MECHANICAL EQUIPMENT FEEDER/CONNECTION SCHEDULE ON SHEET E-601. WATER HEATER. SEE EQUIPMENT CONNECTION SCHEDULE ON SHEET E-601. CONTROL CIRCUIT THROUGH LIGHTING SWITCH BANK. SEE DETAIL ON SHEET E-501. FURNISH AND INSTALL GFI DUPLEX RECEPTACLE ADJACENT TO UNIT IF NOT EXISTING/FURNISHED WITH EQUIPMENT. CIRCUIT AS INDICATED, FURNISH WEATHER PROOF ENCLOSURES AND COVERS AS REQUIRED. JUNCTION BOX INSTALLED FLUSH WITHIN DRYWALL. EXTEND 1/2" CONDUIT TO ABOVE CEILING TO HVAC UNIT FOR THERMOSTAT/REMOTE SENSOR. DUCT SMOKE DETECTOR/REMOTE TEST STATION: DUCT MOUNTED SMOKE DETECTOR IS EXISTING. CONTRACTOR SHALL INTERLOCK SMOKE DETECTOR WITH HVAC UNIT, REMOTE TEST ALARM STATION AND FIRE ALARM SYSTEM (IF APPLICABLE). MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A COMPLETE SYSTEM. HVAC UNIT TO SHUT DOWN UPON ACTIVATION OF SMOKE DETECTOR. COORDINATE WITH LANDLORD TO AVOID CONFLICTS IN FIELD. INSTALL A DELIVERY BUZZER SYSTEM AS SHOWN, INCLUDING PUSH-BUTTON AT REAR DOOR, TRANSFORMER AND BUZZERS AS INDICATED. COORDINATE ALL REQUIREMENTS WITH TENANT AS TO LOCATIONS. REFER TO DETAIL ON SHEET E-501 FOR ADDITIONAL INFORMATION. AIR CURTAIN. AIR CURTAIN SPEED CONTROL. PROVIDE FIRE ALARM JUNCTION BOX. COORDINATE FINAL TIE-IN AND TESTING OF FIRE ALARM SYSTEM. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO BID. PROVIDE FIRE ALARM MANUAL PULL STATION AND CONNECT TO PANEL. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. PROVIDE FIRE ALARM HORN/STROBE, AND CONNECT TO LANDLORD'S MAIN FIRE ALARM SYSTEM. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. PROVIDE FIRE ALARM STROBE AND CONNECT TO LANDLORD'S MAIN FIRE ALARM SYSTEM. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. PROVIDE FIRE ALARM CEILING MOUNTED SMOKE DETECTOR AND CONNECT TO PANEL. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. PROVIDE FIRE ALARM REMOTE ANNUNCIATOR PANEL,AND CONNECT TO PANEL. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. PROVIDE 8" X 8" X 4" DEEP FLUSH-MOUNTED JUNCTION BOX WITH BUSHED-HOLE SCREW COVER, CENTER AT 16" AFF BEHIND TECH RACK, FOR CAT 6 CABLES. TERMINATE COMMUNICATIONS CONDUITS AT BOX AND EXTEND CABLES TO TECH RACK. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. USER: JGRAY 13 REFER TO MECHANICAL PLAN FOR LOCATION OF MECHANICAL EQUIPMENT. FIELD VERIFY EXACT LOCATIONS. PROVIDE AND INSTALL ALL CONVENIENCE RECEPTACLES, SAFETY SWITCHES, WIRING, OR OTHER EQUIPMENT TO ENSURE A COMPLETE AND OPERABLE HVAC SYSTEM. ALL WALL MOUNTED RECEPTACLES, SWITCHES, AND COVERPLATES SHALL MATCH WALL, REFER TO SHEET A-201 FOR FINISHES. THE CEILING RECEPTACLES AND COVERPLATES SHALL MATCH CEILING. CONDUIT FOR DATA/TELEPHONE OUTLETS SHALL HAVE NO MORE THAN THREE 90° BENDS. IF THE CONDUIT RUN REQUIRES MORE THAN THREE 90° BENDS, PROVIDE A PULL/JUNCTION BOX AFTER EACH SET OF THREE 90° BENDS. LABEL ALL COVERPLATES ON INSIDE FACE OF PLATE WITH CIRCUIT NUMBER AND PANEL DESIGNATION. I.E. "A-1". CIRCUIT SHALL BE WRITTEN WITH PERMANENT MARKER IN A CONTRASTING COLOR. ALL TELEPHONE/DATA CABLING TO BE RUN IN CONDUIT TO 6" ABOVE CEILING. PROVIDE 6' OF EXTRA CABLING AT ALL TELEPHONE/DATA TERMINATIONS. ALL CABLING SHALL BE PLENUM RATED. RUN PHONE/DATA CABLING (CAT 6) COMPLETELY IN CONDUIT IF LOCAL CODES/MUNICIPALITIES REQUIRE IT (FIELD VERIFY). ALL CABLING SHALL BE ROUTED AWAY FROM ALL ELECTRIC EQUIPMENT (WITHIN 18") AND SECURED TO STRUCTURE ABOVE. ALL TELEPHONE/DATA CABLING FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL MOUNTING HEIGHTS FROM THE CENTERLINE OF THE BOX TO THE FINISHED FLOOR ARE AS FOLLOWS, UNLESS NOTED OTHERWISE ON PLAN: SWITCHES-48", ELECTRICAL/TELEPHONE/DATA OUTLETS-18", THERMOSTATS-5'-0", TOP OF PANELBOARD-6'-6". ALL ROOF PENETRATIONS TO BE COORDINATED WITH THE LANDLORD'S DESIGNATED ROOFING CONTRACTOR. FLEXIBLE CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO MILLWORK, INTERIOR LIGHTING FIXTURES, AND EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 6'-0". CONDUIT AND OUTLETS FOR SECURITY, DATA, TELEPHONE, AND ELECTRIC MAY REQUIRE REMOVAL OF CONCRETE SLAB OR ROUTING OF CONDUIT UNDER FLOOR IN SPACE BELOW. ALL WORK TO BE COORDINATED WITH THE LANDLORD DISCONNECT SWITCHES SHALL BE GENERAL DUTY IN APPROPRIATE NEMA ENCLOSURES. A LINE VOLTAGE, HORSEPOWER RATED DISCONNECT SWITCH SHALL BE INSTALLED ADJACENT TO EACH MOTOR. TRANSFORMER NEUTRALS SHALL BE SECURELY GROUNDED TO THE BUILDING STEEL AND COLD WATER PIPING PER THE N.E.C. AND LOCAL CODE REQUIREMENTS. INSTALL TRANSFORMERS ON VIBRATION ISOLATION PADS. ELECTRICAL EQUIPMENT EXPOSED TO WEATHER MUST BE WEATHERPROOF. ALL TEMPORARY WIRING SHALL BE REMOVED WHEN PERMANENT POWER IS AVAILABLE. IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING "AS BUILT" DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING SAME TO SUNGLASS HUT. CONTRACTOR SHALL PURCHASE AT SGH NATIONAL ACCOUNT AGREED PRICING, ALL DISCONNECT SWITCHES, ELECTRIC DISTRIBUTION PANEL, CIRCUIT BREAKERS AND FUSES. CONTACT SUNGLASS HUT'S NATIONAL ACCOUNT REPRESENTATIVE FOR PRICING INFORMATION AND INCLUDE IN BID. SEE ARCHITECTURAL ELEVATIONS FOR ADDITIONAL INFORMATION ON PLACEMENT OF OUTLETS AND SWITCHES. FOR ALL CASHWRAP MILLWORK ELECTRIC, DATA, AND TELEPHONE OUTLETS, REFER TO THE DETAILS ON SHEET E-501. ALL DATA/PHONE CABLING MUST BE PROPERLY IDENTIFIED WITH NUMBER AND/OR COLOR SYSTEM AT BOTH ENDS. ANY PENETRATIONS THROUGH FIRE-RESISTANT/RATED WALLS, PARTITIONS, FLOORS, AND CEILINGS SHALL BE FIRESTOPPED USING APPROVED UL METHODS TO MAINTAIN THE FIRE RESISTANCE RATING. RECEPTACLE CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. RECEPTACLE CIRCUITS ABOVE 250'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. ELECTRICAL CONTRACTOR SHALL PROVIDE JUNCTION BOX AND RACEWAY FOR THERMOSTATS AT 60" A.F.F. THERMOSTATS AND TEMPERATURE SENSORS INSTALLED AND WIRED BY MECHANICAL CONTRACTOR. COORDINATE EXACT LOCATIONS WITH MECHANICAL CONTRACTOR. TYPICAL OF ALL. DUCTWORK AND PIPING SHALL NOT BE ROUTED OVER ELECTRIC PANEL. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REVIEW ALL ARCHITECTURAL, MECHANICAL, PLUMBING, STRUCTURAL, FIRE ALARM AND FIRE PROTECTION AND ELECTRICAL DRAWINGS AND NOTES TO ENSURE THAT ALL ELECTRICAL REQUIREMENTS ARE MET. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES AND ORDINANCES. GC'S ELECTRICIAN TO PULL ALL LOW VOLTAGE TELEPHONE AND DATA LINES INCLUDING INSTALLATION OF DEVICES. PUNCH DOWN OF LINE(S) AT THE TERMINAL BOARD IS BY OTHERS. REFER TO SHEET E-501 FOR ABBREVIATIONS AND SYMBOLS REFER TO SHEET G-002 FOR RESPONSIBILITY SCHEDULE. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150343 Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com TX Registration Number: #F-9566 SEAL LA PLAZA MALL 2 AT 1 D C SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM B SGH STORE #: 6078 DRAWN BY: EDS REVIEWED BY: KAH AUTHORIZED FOR: POWER PLAN A A1 SCALE: E-101 NOT USED 1 2 3 4 5 6 7 8 9 10 11 12 13 14 2 3 4 5 6 7 8 9 10 11 KEY NOTES 1. 2. 3. K 4. 5. 6. 7. 8. 9. J 10. LIGHTING SPECIFICATIONS MARK TYPE SUPPLIER A3W B3 EM H A3W CONTECH LIGHTING B3 EM PHILIPS C4W TW4'-0" RP X1A PRODUCT TYPE DESCRIPTION WATT #LP LAMP LED TRACK HEAD - GIMBAL RING, WHITE, PROVIDE FACTORY STICKER LIMITING LAMP TO 13 WATTS (WHITE) 4' LED STRIP FIXTURE 'FLUXSTRAM' 3500K, 3100 LUMENS W/ EMERGENCY PACK RECESSED ADJASTABLE-1 LIGHT ACCENT/DOWNLIGHT LED SOURCE (WHITE) #LED12P30SD30KNFL (1) 75W PAR 30 LAMP CTL830-P (WHITE) 13 - LF-4-FR-31-35-U-DZT-EM 31 N/A LED INCLUDED C4W CONTECH LIGHTING RAN7530X1-P-HB24 (WHITE) 13 1 TW CONTECH LIGHTING LT-(2, 4, 6, 8)-P N/A N/A N/A RP DUAL LIGHT LG-2-S 300 N/A N/A EMERGENCY 250 WATT REMOTE POWER PACK TO BE USED WITH FIXTURE TYPES B1, B3 OR C1 SERIES X1A LIGHT ALARMS LED INCLUDED SEMI RECESSED EXTRUDED ALUMINUM EDGE LIT EXIT SIGN WITH RED LETTERS FOR CEILING OR WALL MOUNTING. RED LED INCLUDED. SPLEDWRCD #LED12P30SD30KNFL LED FIXTURE N/A 3 11. 12. 13. 14. 15. 16. 12 13 14 GENERAL NOTES CIRCUIT VIA MASTER LIGHTING SWITCH BANK. SEE LIGHTING CONTROL DETAIL ON E-501. CIRCUIT SIGN LIGHTING THROUGH TIME CLOCK. FURNISH AND INSTALL JUNCTION BOX AND DISCONNECT TOGGLE TYPE SWITCH WITH MINIMUM 12" WHIP PER N.E.C. LOCATE ABOVE CEILING NEAR ACCESS PANEL IN CONCEALED LOCATION. CIRCUIT THROUGH TIMECLOCK/CONTACTOR. SEE ARCHITECTURAL SHEETS FOR SIGN LOCATION. FURNISH AND INSTALL GANGED SWITCH FOR LOCAL LIGHTING SWITCHES. PROVIDE COMMON FACEPLATE OR MULTIPLE FACEPLATES OF EQUAL WIDTHS. SEE LIGHTING CONTROL DETAIL ON E-501. CONNECT EMERGENCY FIXTURE TO EMERGENCY/NIGHT LIGHTING CIRCUIT (A-2) PER NEC 700-12(A) AND LIFE SAFETY CODE. EMERGENCY FIXTURE TO BE SERVED BY LOCAL LIGHTING CIRCUIT AHEAD OF ALL SWITCHING.PER NEC 700-12(A) AND LIFE SAFETY CODE. FURNISH AND INSTALL CEILING MOUNTED OCCUPANCY SENSOR. FURNISH AND INSTALL WALL MOUNTED OCCUPANCY SENSOR FURNISH AND INSTALL CONDUIT FROM TECK RACH TO 24" ABOVE CEILING FOR TERMINATION AT TRAFFIC COUNTER PROVIDE CAT6 DATA CABLE WITH MINIMUM 6FT COILED AND LABELED CABLE AT BOTH ENDS. FURNISH AND INSTALL CONDUIT FROM TECH RACK TO 24" ABOVE CEILING FOR TERMINATION AT WIRELESS POWER INJECTOR BRICK/WIRELESS ACCESS POINT PROVIDE CAT6 DATA CABLE WITH MINIMUM 6FT COILED AND LABELED CABLE AT BOTH ENDS. SECURITY CAMERA FOR CCTV SYSTEM. REFER TO DETAIL ON SHEET E-501 FOR INSTALLATION REQUIREMENTS. PROVIDE ADDITIONAL STRUCTURAL SUPPORT AS REQUIRED FOR MOUNTING OF REMOTE POWER PACK (78lbs). FURNISH AND INSTALL LIGHTING OVERRIDE SWITCH IN MASTER SWITCH BANK (SEE A8/E-501). FURNISH AND INSTALL TRACK LIGHTING CURRENT LIMITING BREAKERS ON TRACK. AIR CURTAIN 18"x18" CORIAN ACCESS PANEL 1. 2. 3. 4. 5. 6. 7. 8. 9. G 10. 11. 12. 13. 14. 15. 16. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150343 Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com TX Registration Number: #F-9566 SEAL AT F EMERGENCY (EM) LUMINAIRES THAT ARE NOT POWERED FROM INVERTER SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF. ALL NIGHT-LIGHT (NL) LUMINAIRES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE CONTRACTOR SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON-SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT SGH PROJECT MANAGER FOR DIRECTION. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT SGH PROJECT MANAGER FOR DIRECTION. LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE THRU-WIRING WHEREVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. LIGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE THRU-WIRING, ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPS FURNISHED BY SGH. CONTRACTOR IS RESPONSIBLE TO ENSURE THE ADJUSTABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, CONTRACTOR SHALL CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH SGH. EMERGENCY AND EXIT LUMINAIRES SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST NATIONAL ELECTRICAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL-VOLTAGE WITH BATTERY BACKUP (120/277 VOLT INPUT). INSTALL A CENTRAL BATTERY SYSTEM WHERE THE USE OF INDIVIDUAL BATTERY UNITS ARE PROHIBITED BY LOCAL CODES. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT SGH PROJECT MANAGER FOR DIRECTION. CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND QUANTITY OF LIGHTING FIXTURES. CONTRACTOR IS RESPONSIBLE FOR ALL REFLECTED CEILING PLAN NOTES ON ARCHITECTURAL DRAWINGS. LOW VOLTAGE WIRING: THE GC IS RESPONSIBLE TO DETERMINE IF LOW VOLTAGE WIRING IS REQUIRED BY EITHER LL OR BUILDING DEPARTMENT TO BE ENCASED IN CONDUIT, IF SO, CONDUIT TO BE PROVIDED AND INSTALLED BY GC'S ELECTRICIAN. REFER TO SHEET E-501 FOR SYMBOLS LEGEND. REFER TO RESPONSIBILITY SCHEDULE ON SHEET G-002. CONTRACTOR SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVY CONSTRUCTION PERIOD. E E1 SCALE: LA PLAZA MALL 1 LIGHTING FIXTURE SCHEDULE D 11 TW12'-0" C4W STOCK ROOM 6 101 AP C4W SALES 100 S TC NL/EM C4W C4W 9 SUNGLASS HUT LA PLAZA MALL 2 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM TW10'-0" A-6 RP S C 3 A-4 X1A TW4'-0" C4W 5 TW6'-0" NL/EM - A3W A3W A3W 10 (TYP) MALL COMMON AREA (N.I.C.) 1 C4W A3W A3W A3W A3W A3W A3W 4 12 B A3W A3W A-10 A3W A3W 1 A3W A3W 5 A3W A3W A3W A3W A3W A3WA3WA3W A3W A3W A3W A3W A3W A3WA3W A3W A3W S P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\E-102_06078.dwg ADJACENT TENANT B3 PLOTTED: 7/16/2015 - 4:04 PM C S S C (TYP) USER: JGRAY - SPEAKER (TYPICAL) TW12'-0" LAYOUT: E-102 ADJACENT TENANT A3W A3W A3W S C A3W A3W A3W A3W A3W A3W SGH STORE #: 6078 S S C DRAWN BY: EDS EM A-12 A REVIEWED BY: RAP - AUTHORIZED FOR: ADJACENT TENANT A9 A1 SCALE: LIGHTING PLAN & LIGHTING LEGEND PLAN NORTH LIGHTING PLAN 1 SCALE: 2 3 4 5 6 7 8 E-102 NOT USED 9 10 11 12 13 14 2 3 4 5 6 7 8 9 10 11 12 13 ELECTRICAL SYMBOLS IG @ 16" 120 VOLT IG DUPLEX RECEPTACLE @ 16" 120 VOLT DOUBLE DUPLEX (QUAD) RECEPTACLE @ 16" 120 VOLT SIMPLEX RECEPTACLE @ 16" 208V OR 120/208V RECEPTACLE @ 16" JUNCTION BOX T THERMOSTAT SN HVAC SENSOR ZD ZONE DAMPER TELEPHONE OUTLET BOX @ 16" DATA OUTLET BOX @ 16" @ 16" TELEPHONE OUTLET - FLOOR MOUNTED DATA OUTLET BOX - FLOOR MOUNTED DATA/TELEPHONE - FLOOR MOUNTED VC WALL MOUNTED VOLUME CONTROL @ 48" VS WALL MOUNTED VARIABLE SPEED CONTROLLER @ 48" K KEYPAD P TC TRAFFIC COUNTER AP WIRELESS ACCESS POINT FABP FIRE ALARM BOOSTER PANEL FAAP FIRE ALARM ANNUNCIATOR PANEL (REMOTE) S CEILING MOUNTED PHOTO/IONIZATION DETECTOR H CEILING MOUNTED HEAT DETECTOR S PHOTO/IONIZATION DETECTOR-DUCT MOUNTED V ALARM HORN WITH VISUAL INDICATOR V VISUAL ALARM INDICATOR WITH NO HORN B ALARM BELL S FIRE ALARM SPEAKER WITH VISUAL INDICATOR S FIRE ALARM SPEAKER F MANUAL PULL STATION PS PRESSURE SWITCH TS TAMPER SWITCH R FIRE ALARM RELAY FA FIRE ALARM JUNCTION BOX D H MAGNETIC DOOR HOLDER-WALL OR FLOOR MOUNTED AS INDICATED PUSHBUTTON G GLASS BREAK SENSOR WALL SWITCH - NUMBER INDICATES 2, 3 OR 4 POLE; LETTER INDICATES FIXTURE(S) TO BE CONTROLLED BY SWITCH S C SECURITY CAMERA @ 48" S CEILING MOUNTED SPEAKER O S OCCUPANCY SENSOR @ 48" O S OCCUPANCY SENSOR - CEILING MOUNTED DOUBLE REMOTE HEAD DS DAYLIGHT SENSOR TRACK HEAD DD DIMMING SENSOR WALL MOUNTED FIXTURE V VACANCY SENSOR EM/NL WALL MOUNTED FIXTURE CURRENT LIMITER - NUMBER INDICATES AMPERAGE OF BREAKER RECESSED CAN LIGHT TS TIMER SWITCH @ 48" D DIMMER SWITCH @ 48" @ 80" SEAL DEDICATED QUAD RECEPTACLE 1. F6 SCALE: CEILING MOUNTED EXIT SIGN F11 NOT USED SCALE: MAGNETIC COMBINATION MOTOR STARTER OR CONTACTOR DISCONNECT SWITCH WALL MOUNTED EMERGENCY LIGHT C E R CEILING MOUNTED EXISTING RELOCATED S LAYOUT: E-501 P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\E-501_06078.dwg PLOTTED: 7/16/2015 - 4:04 PM USER: JGRAY AWG B C BREAKER BUILDING BUILDING MANAGEMENT SYSTEM C CONDUIT CABLE TELEVISION SYSTEM CLOSED CIRCUIT TELEVISION CIRCUIT CEILING HEATER HEATING, VENTILATING & A/C HERTZ KILOVOLT-AMPS KILOWATTS KILOWATT-HOUR MAX MCA MCB MH MIN MOCP dB DECIBEL DIA (OR Ø) DIAMETER DISC DISCONNECT DN DOWN DWG DRAWING DPST DOUBLE POLE SINGLE THROW ETR EWC EXH EX, EXIST LOCKED ROTOR AMPS LIGHTING M MTD MAXIMUM MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER MANHOLE, METAL HALIDE MINIMUM MAXIMUM OVER CURRENT PROTECTION MOUNTED N/A NEC NEMA NFPA NIC N.O. NTS EXISTING TO REMAIN ELECTRICAL WATER COOLER EXHAUST EXISTING F OC OSHA P PF PH PVC SCALE: REFLECTED CEILING PLAN, REVISION, REVISE REMOVE EXISTING RUNNING LOAD AMPS ROOM NOT APPLICABLE NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MFR'S ASSOC. NATIONAL FIRE PROTECTION ASSOC. NOT IN CONTRACT NORMALLY OPEN NOT TO SCALE NOT USED 1 DVD-R QUADRUPLEX RECEPTACLE SQUARE FEET, SQUARE FOOT SINGLE POLE SINGLE THROW THROUGH TYPICAL U UL UON UPS V VA MONITOR UNDERWRITERS LABORATORIES, INC. UNLESS OTHERWISE NOTED UNINTERRUPTABLE POWER SUPPLY 1. CAMERA (QUANTITY ON PLAN) VOLT VOLT-AMPERE WATT FIRE ALARM FIRE ALARM CONTROL PANEL FULL LOAD AMPS FOOT, FEET REFER TO ARCH DETAILS ON SHEET A-502 AND RESPONSIBILITY SCHEDULE ON SHEET G-002 FOR ADDITIONAL INFORMATION. EXTEND CABLE TO PROPOSED HEAD END EQUIPMENT LOCATION. PROVIDE ENOUGH EXCESS CABLE TO REACH ANY WALL IN BACK ROOM. COIL AND MARK CABLE AS CCTV. HEAD END EQUIPMENT LOCATION MUST BE WITHIN 10' OF THE 'NETWORK SWITCH ACCESS'. W W 2. FOR CAMERAS, PROVIDE WHITE PLENUM RATED CAT 6 CABLING. COIL 5' OF CABLING AT EACH CAMERA LOCATION FOR CONNECTIONS. 3. PROVIDE RJ-45 CONNECTORS AT CAMERA LOCATIONS ONLY. CONNECTORS NOT NEEDED AT THE HEAD END EQUIPMENT LOCATION. A6 ABBREVIATIONS AND SYMBOLS 1 2 SCALE: 3 4 5 FURNISH AND INSTALL ANNUNCIATING DEVICES, SEE SHEET E-101 FOR LOCATION AND QUANTITY. GENERAL SALES (a) (SPST) DISPLAY CASE RECEPTACLES (c) (SPST) NOTE: GENERAL CONTRACTOR TO LABEL LIGHT SWITCHES. POWER CONTACTOR AND TC1 FROM CIRCUIT A-15 CONTACTOR CONTROLLED BY TIMECLOCK A-4 SPARE SPARE SPARE C2 6 SEE SHEET E-101 FOR ACTUAL NUMBER OF DEVICES, AND ADDITIONAL NOTES. ALL MATERIALS SHALL BE NEW AND BEAR UL LABELS. SUPPLY SHOP DRAWINGS FOR FIRE ALARM SYSTEM TO LOCAL AUTHORITY FOR APPROVAL PRIOR TO INSTALLATION. 4. FURNISH AND INSTALL ALL LABOR AND MATERIALS REQUIRED FOR A COMPLETE INSTALLATION AS INDICATED. 5. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NEC, NFPA, STATE AND LOCAL CODES. 1. SALES SALES SALES SALES SALES SALES TRACK LIGHTS AREA DISPLAY CASES AREA DISPLAY CASES AREA DISPLAY CASES AREA DISPLAY CASES AREA DISPLAY CASES SUNGLASS HUT LA PLAZA MALL NOTES: ALL CONTACTORS ARE NORMALLY OPEN, ELECTRICALLY HELD CLOSED, WITH THE NUMBER OF POLES AS SHOWN. SUPPLY POWER TO CONTACTORS THRU A-15 IN ALL CASES. LOCATE CONTACTORS AND TIME CLOCK ADJACENT TO PANEL 'A'. UPON ALARM SIGNAL FROM ANY INITIATING DEVICE THE FIRE ALARM PANEL SHALL: A. INITIATE AN ALARM SIGNAL AT TENANT'S PANEL AND LANDLORD'S MAIN FIRE ALARM SYSTEM. B. SHUT DOWN TENANT'S HVAC SYSTEM (IF APPLICABLE) C. INITIATE MALL'S AND TENANT'S HORN/STROBES. D. ACTIVATE THE TENANT ZONE SMOKE CONTROL EXHAUST SYSTEM AND THE MALL OUTSIDE AIR SUPPLY. (IF APPLICABLE) E. NOTIFY LOCAL FIRE DEPARTMENT OF FIRE EMERGENCY LOCATION. 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 DRAWN BY: EDS REVIEWED BY: KAH AUTHORIZED FOR: ELECTRICAL DETAILS & ABBREVIATIONS SCALE: 7 A-6 A-14 A-16 A-18 A-20 A-22 SPARE SPARE 1. 2. 3. A8 CCTV SYSTEM STOREFRONT SIGN POWER CONTACTOR FROM CIRCUIT A-15 THRU SWITCH 'c' 3 T THRU TYP V 'C2' 2 S SF SPST V GENERAL CONTRACTOR SHALL CONTRACT WITH MALL APPROVED FIRE ALARM CONTRACTOR 'GLOBAL RISK CONSULTANT'S' FOR FINAL CONNECTION TO LANDLORD'S MAIN FIRE ALARM SYSTEM. VERIFY EXACT LOCATION AND REQUIREMENTS WITH MALL OPERATIONS MANAGER. R RCP REV REX RLA RM J A-10 C1 D6 POWER FACTOR PHASE POLYVINYL CHLORIDE A1 SCALE: FIRE ALARM JUNCTION BOX. SEE SHEET E-101 FOR LOCATION AND ADDITIONAL NOTES ON CENTER OCCUPATIONAL SAFETY &HEALTH ADMIN. V N E A KVA KW KWH LRA LTG D FA FACP FLA FT H L C CATV CCTV CKT CLG B GAS, GROUND GENERAL CONTRACTOR GROUND FAULT INTERRUPTER GROUND K BKR BLDG BMS CHECK LENGTH OF SCREWS BEFORE ATTACHING OUTLETS TO MILLWORK. VERIFY SCREWS ARE NOT TOO LONG, SO AS NOT TO DAMAGE OTHER SIDE OF CASHWRAP WHEN SCREWS ARE TIGHTENED. 1 REGISTER CASHWRAP ELEVATION FURNISH AND INSTALL DUCT MOUNTED SMOKE DETECTORS FOR HVAC EQUIPMENT AND TIE INTO TENANT'S FIRE ALARM SYSTEM. O G HTR HVAC HZ ONE (1) 1-1/4" DIA. RIGID CONDUIT FOR TELE/DATA STUBBED BELOW CASHWRAP BASE. PROVIDE 2 CAT6 CABLES. MASTER LIGHTING SWITCH BANK ABBREVIATIONS D ONE (1) 1" DIA. RIGID CONDUIT FOR POWER STUBBED BELOW CASHWRAP BASE (FRAME WARMER) ONE (1) 1" DIA. RIGID CONDUIT FOR POWER (IG) STUBBED BELOW CASHWRAP BASE (1 CIRCUIT) WALL MOUNTED EXIT SIGN REMOTE EMERGENCY POWER PACK G GC GFI, GFCI GRND CKT#1 GENERAL DETAIL NOTES: EQUIPMENT DISCONNECT SWITCH ABOVE FINISHED CEILING ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERES AMERICAN NAT'L STANDARDS INST. ARCHITECT, ARCHITECTURAL AMERICAN SOCIETY OF HEATING, REFRIGERATION & AC ENGINEERS AMERICAN WIRE GAUGE DEDICATED QUAD RECEPTACLE DEVICE LOCATIONS EM/NL RECESSED CAN LIGHT NON-MAGNETIC MANUAL MOTOR STARTER AFC AFF AFG AMP ANSI ARCH ASHRAE CKT#2 CUT HOLES AS REQUIRED AT REAR OF BASE FOR FLEX CONDUIT MOTION DETECTOR COMBINATION EMERGENCY AND EXIT LIGHT A DEDICATED DUPLEX RECEPTACLE J J J THREE PHASE MOTOR MAGNETIC STARTER OR CONTACTOR @ 80" SINGLE REMOTE HEAD SINGLE PHASE MOTOR E Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com TX Registration Number: #F-9566 BURGULAR SYSTEM PANEL DOOR CONTACT S OPEN CONSULTANT PROJECT # 150343 DATA OUTLET DC XX TRASH CKT#1 CHIME/BELL TRANSFORMER B JUNCTION BOXES IN CASHWRAP SHALL BE PRE-INSTALLED BY THE MILLWORK MANUFACTURER SUPPLIES PRINTER DATA OUTLET WATER FLOW SWITCH D BAGS @ 60" @ 48" WF BURG A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 EQUIPMENT LOCATIONS M S TELEPHONE FRAME WARMER CASH DRAWER REMOTE ANNUNCIATOR/TEST STATION CHIME/BELL G F FIRE ALARM CONTROL PANEL ALARM HORN DATA/TELEPHONE OUTLET BOX H FACP A 120 VOLT DUPLEX RECEPTACLE FLOOR MOUNTED J RECEIPT PRINTER MONITOR TRANSFORMER (XFMR) 120 VOLT DUPLEX RECEPTACLE CEILING MOUNTED SF = STOREFRONT J LIGHTING/POWER PANELBOARD AT K 120 VOLT DUPLEX RECEPTACLE WP = WEATHERPROOF GFI = GROUND FAULT INTERRUPTER 14 LA PLAZA MALL 1 A11 FIRE ALARM SYSTEM 8 9 SCALE: 10 E- 501 LIGHTING CONTROL DIAGRAM 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 K CONSULTANT PROJECT # 150343 MECHANICAL EQUIPMENT FEEDER/CONNECTION SCHEDULE J FEEDERS ITEM VOLTAGE HP KW M.C.A. (E)RTU 208V 3PH --- --- 30.0 WIRE COND 3#10 THHN 1#10 G 3/4" Shremshock Engineering, Inc. TYPE OF CONN DISC SW BRANCH BREAKER REMARKS THRU DISC. SWITCH 30A 30A-3P SEE NOTE #1 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com TX Registration Number: #F-9566 NOTE: 1. EXISTING WITH UNIT. 2. DISCONNECT IS TO BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR SEAL H G G1 F LANDLORD EXISTING NEW TENANT LANDLORD PROVIDE 1-1/4 "C. FIELD VERIFY PRIOR TO BID. AT GENERAL CONTRACTOR TO PROVIDE J-BOX AS REQUIRED TO EXTEND 1-1/4" C. TO PANEL BOARD. E GENERAL CONTRACTOR TO PROVIDE 4#4 THHN AND 1#8 GROUND AND #8 ISOLATED GROUND IN 1-1/4"C. FROM PANEL TO SWITCHBOARD. USER: JGRAY PLOTTED: 7/16/2015 - 4:04 PM P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\E-601_06078.dwg LAYOUT: E-601 EXISTING ELECTRICAL METER TO REMAIN AS IS. COORDINATE WITH LANDLORD'S REPRESENTATIVE AND LOCAL UTILITY COMPANY. PANEL 'A' 120/208V 3PH, 4W 100A MCB 42 CKT EXISTING 100A FUSED DISCONNECT TO REMAIN. IF NOT IN GOOD CONDITIONS GENERAL CONTRACTOR TO PROVIDE NEW 100A DISCONNECT SWITCH. PROVIDE WITH (3) 70A REPLACEMENT FUSES. D LA PLAZA MALL EQUIPMENT SCHEDULES LEASE LINE SCALE: C-1 C-2 ZONE ZONE "SF" "C" TC FINISH FLOOR APPROX. DISTANCE 30'-0" C 1. 2. 3. 4. B 5. 6. 7. 8. 9. 10. HVAC CIRCUIT BREAKERS TO BE "HACR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. TENANTS ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT K.A.I.C. RATING OF LANDLORD'S DISTRIBUTION EQUIPMENT. FURNISH AND INSTALL TENANTS ELECTRICAL SYSTEM TO MATCH. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT, UNDER LOAD CONDITIONS, TO ±7% BETWEEN PHASES: A/B, B/C, A/C REGARDLESS OF CIRCUITING INDICATED. ELECTRICAL CONTRACTOR SHALL MAINTAIN PROPER CLEARANCE FOR ELECTRICAL EQUIPMENT PER N.E.C. ARTICLE 110.26. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM/ AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. TENANT'S NAME AND SPACE SHALL BE ENGRAVED ON A BAKELITE PLATE WITH 1" HIGH LETTERS. SCREW FASTEN TO THE METER SOCKET AND DISCONNECT SWITCH AT THE SERVICE DISTRIBUTION POINT. ALL CONNECTIONS TO LANDLORD'S SERVICE EQUIPMENT SHALL BE AS DIRECTED BY LANDLORD'S SITE REPRESENTATIVE. TENANT ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TERMINATION EXPENSES. SYSTEM SHALL BE GROUNDED TO THE MAIN BUILDING'S GROUNDING SYSTEM. ELECTRICAL CONTRACTOR SHALL INCLUDE IN BID ALL WORK AND MODIFICATIONS REQUIRED TO COMPLY WITH LANDLORDS TENANT CRITERIA, ENERGY CODES, NATIONAL, STATE AND LOCAL CODES. ALL EQUIPMENT TO BE SUPPLIED AND INSTALLED PER RESPONSIBILITY SCHEDULE AS SHOWN ON THIS SHEET. SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM SGH STORE #: 6078 DRAWN BY: EDS REVIEWED BY: KAH AUTHORIZED FOR: ELECTRICAL SINGLE LINE DIAGRAM AND PANEL SCHEDULES A A9 A1 SCALE: ELECTRICAL SINGLE LINE DIAGRAM 1 2 3 SCALE: 4 5 6 7 8 E-601 PANEL SCHEDULES AND LOAD SUMMARY 9 10 11 12 13 14 3 4 P. 26 05 00 COMMON WORK RESULTS FOR ELECTRICAL A. THE FOLLOWING TERMS SHALL APPLY TO ALL WORK DONE UNDER THIS CONTRACT: 1. K 2. 3. 4. 5. J 6. B. 10. 11. G 12. 13. C. F E USER: JGRAY PLOTTED: 7/16/2015 - 4:04 PM P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\E-701_06078.dwg LAYOUT: E-701 (208v) E. ELECTRICAL EQUIPMENT FURNISHED BY OTHER TRADES OR BY TENANT AND SPECIFIED IN OR SHOWN ON CONTRACT DOCUMENTS SHALL BE INSTALLED AND CONNECTED BY GENERAL CONTRACTOR, EXCEPT AS OTHERWISE NOTED. PROVIDE BRANCH CIRCUIT CONNECTIONS TO ELECTRICALLY OPERATED EQUIPMENT FURNISHED BY OTHERS AS SPECIFIED IN OR SHOWN ON THE CONTRACT DOCUMENTS. TEMPORARY WIRING FOR OTHER CONTRACTORS SHALL BE INSTALLED BY THE GENERAL CONTRACTOR WHO SHALL BE ENTIRELY RESPONSIBLE TO THE TENANT FOR THE SAFE AND SATISFACTORY OPERATION OF SAID TEMPORARY WIRING. CONTRACTOR REQUIRING SUCH TEMPORARY WIRING SHALL PAY FOR ALL DAMAGE TO PROPERTY RESULTING FROM ITS USE. COMPLY WITH LATEST REQUIREMENTS OF OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA). PROVIDE PERSONNEL GROUND FAULT PROTECTION ON ALL TEMPORARY POWER AND LIGHTING CIRCUITS 30 AMPERES OR LESS. GROUND FAULT CIRCUIT INTERRUPTERS ON CONSTRUCTION CIRCUITS ARE NOT REQUIRED WHERE CIRCUIT IS A PERMANENT CIRCUIT TO BE A PART OF THE COMPLETED BUILDING. HOWEVER, CONTRACTOR SHALL PROVIDE APPROVED CORD SETS INCORPORATING GFCI PROTECTION FOR PERSONNEL. SEE THE LOCALLY ADOPTED EDITION OF THE N.E.C. ALL FINISH PAINTING IS TO BE PERFORMED BY GENERAL CONTRACTOR EXCEPT THAT THIS CONTRACTOR SHALL RESTORE TO ORIGINAL CONDITION ANY PAINTING DEFACED BY THIS CONTRACTOR AFTER ORIGINAL PAINTING. ANY ACCESS PANELS REQUIRED, BUT NOT SPECIFIED OR SHOWN ON DRAWINGS, SHALL BE FURNISHED BY GENERAL CONTRACTOR WITH DESIGN TO BE APPROVED BY ARCHITECT BEFORE STARTING INSTALLATION. H. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS NECESSARY TO COMPLETE THE WORK OR WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF CONTRACT. 5. 6. 7. K. B L. O. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING, THROUGH SHOP DRAWING SUBMITTAL PROCESS, BY TENANT'S CONSTRUCTION MANAGER PRIOR TO ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. 1 2 3 THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING CONDUIT, FIRE ALARM SYSTEM, SWITCH GEAR, PITCH POCKETS AND EQUIPMENT, ETC. UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, CONDUIT AND SWITCH GEAR PRIOR TO REMOVAL. PITCH POCKETS SHALL BE REMOVED AND THE ROOF PATCHED, AS REQUIRED BY THE LANDLORD. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO LIKE NEW CONDITION. EXISTING ABANDONED CONDUIT OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE, ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED CONDUIT MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN PROPOSAL. U. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. V. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL CONDUIT, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. W. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, WIRE, UNISTRUT, C-CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. X. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO OTHER CONDUIT OR PIPING. HANGERS UPPER ATTACHMENT MUST BE SUPPORTED FROM THE TOP OF THE BAR JOIST. HANGING FROM METAL DECK IS NOT PERMITTED. WHERE INTERFERENCES OCCUR, IN ORDER TO SUPPORT CONDUIT, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, JUNCTION BOXES, ACCESS DOORS, OTHER EQUIPMENT SERVICE REQUIREMENTS AND/OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA. Y. UPON COMPLETION OF THE WORK, GENERAL CONTRACTOR SHALL FURNISH TO THE ARCHITECT A CERTIFICATE OF INSPECTION AND APPROVAL FROM THE ABOVE DEPARTMENT BEFORE FINAL PAYMENT ON CONTRACT WILL BE ALLOWED. Z. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND GROUNDS BEFORE ANY EQUIPMENT IS CONNECTED. WHEN DIRECTED BY ARCHITECT, DEMONSTRATE BY PROPER VOLTAGE MEGGER TEST OF INSULATION RESISTANCE OF ANY CONDUCTORS AND REPLACE ALL CONDUCTORS WHICH FAIL SAID TESTS UNTIL ALL CONDUCTORS ARE FREE FROM INSULATION FAULTS. AG. GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS PER THE DOCUMENTS PROVIDED BY THE TENANT. AH. MANUFACTURER'S CATALOG CUTS MAY BE SUBMITTED FOR STANDARD CATALOG LIGHTING FIXTURES AND OTHER EQUIPMENT. CATALOG CUTS MAY BE MARKED UP TO MEET THE PROJECT SPECIFICATIONS. CUTS SHALL BE MARKED TO INDICATE MODEL NUMBER, SIZE, TYPE, COLOR, RATING, ETC., OF THE ITEM TO BE FURNISHED. AI. AK. SHOULD DEFECTS DEVELOP WITHIN GUARANTEE PERIOD, GENERAL CONTRACTOR SHALL, UPON NOTICE OF SAME, REMEDY SUCH DEFECTS AND HAVE DAMAGES TO OTHER WORK OR FURNISHINGS CAUSED BY DEFECTS OR WORK OR CORRECTIONS TO SAME REPAIRED AND/OR REPLACED AT THIS EXPENSE TO CONDITION BEFORE SUCH DEFECTS OR DAMAGE. 4 5 6 7 10 11 G. 1. 2. 3. 4. 5. TITLE PAGE: TITLE OF JOB, LANDLORD, OWNER ADDRESS, DATE OF SUBMISSION, CONTRACTOR, AND ENGINEER. INDEX LIST OF MAJOR EQUIPMENT USED IN PROJECT ACCOMPANIED BY CONTRACTOR PURCHASE ORDER NUMBERS AND SUPPLIERS' NAMES AND ADDRESSES. H. ONE COPY OF EACH SHOP DRAWING GROUPED BY TYPES OF EQUIPMENT, I.E., LIGHTING FIXTURES, PANELBOARDS, ETC. SECTION FOR EACH SYSTEM, INCLUDING: a. BRIEF DESCRIPTION OF SYSTEM OPERATION WITH LOCATION OF MAJOR COMPONENTS. b. LIST OF ITEMS IN SYSTEM REQUIRING PERIODIC SERVICE. REQUIRES SEPARATE SECTION FOR EACH OF: ELECTRICAL DISTRIBUTION SYSTEM FROM THE SERVICE ENTRANCE TO EACH LIGHTING AND POWER PANEL AND OTHER SYSTEMS (I.E. CONTROL SYSTEMS AND ANY OTHER GENERAL I. CONTRACTOR SYSTEM LISTED IN THESE SPECIFICATIONS.) AM. OWNER SHALL PROVIDE A COMPLETE 12-MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY TENANT AND TENANT'S VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONIES SHOULD BE INCLUDED J. IN THE BID. AN. AT THE END OF THE PROJECT, THIS CONTRACTOR SHALL CLEAN ALL EQUIPMENT, INCLUDING LIGHT FIXTURES, TO THE SATISFACTION OF OWNER. ALL DUST, DIRT, DEBRIS, PAINT AND FOREIGN MATTER SHALL BE REMOVED FROM ALL EQUIPMENT. 26 05 19 LOW VOLTAGE ELECTRICAL POWER CONDUCTORS A. SWITCHES SHALL BE QUICK-MAKE, QUICK-BREAK. THE OPERATING HANDLE SHALL BE AN INTEGRAL PART OF THE BOX, NOT THE COVER. PROVISIONS FOR PADLOCKING THE SWITCH IN THE "OFF" POSITION WITH AT LEAST THREE LOCKS SHALL BE PROVIDED. SWITCHES SHALL HAVE A DUAL COVER INTERLOCK TO PREVENT UNAUTHORIZED OPENING OF THE SWITCH DOOR WHEN THE HANDLE IS IN THE "ON" POSITION, AND TO PREVENT CLOSING OF THE SWITCH MECHANISM WITH THE DOOR OPEN. THE HANDLE POSITION SHALL INDICATE WHETHER THE SWITCH IS "ON" OR "OFF". SWITCHES SHALL BE FURNISHED IN NEMA 1 GENERAL PURPOSE ENCLOSURE EXCEPT ALL SWITCHES LOCATED OUTDOORS SHALL BE NEMA 3R WEATHERPROOF (WP). NEMA 3R ENCLOSURE SHALL BE MANUFACTURED FROM GALVANIZED STEEL. ENCLOSURES SHALL HAVE A GRAY BAKED ENAMEL FINISH, ELECTRODEPOSITED, ON CLEANED, PHOSPHATIZED STEEL. L. ALL FUSES SHALL BE BUSSMANN, SIZES AS NOTED ON DRAWINGS. M. ALL FUSES SHALL BE UL LISTED, CURRENT-LIMITING TYPE, MINIMUM 200,000 AMPS INTERRUPTING CAPACITY. N. FUSES 1 AMP AND ABOVE SHALL BE BUSSMANN "LOW PEAK" RK-1. 250 VOLT FUSES SHALL BE USED ON 208/120 VOLT SYSTEMS. R. FURNISH AND INSTALL CIRCUIT BREAKER TYPE POWER, HEATING AND LIGHTING PANELBOARD AS SHOWN ON THE DRAWINGS. CONDUCTORS MAY BE STRANDED FOR SIZES #10 AWG AND LARGER. CONDUCTORS SIZE #12 AND SMALLER SHALL BE SOLID (NOT STRANDED). S. PANELBOARD SHALL BE LISTED UNDER UL 67 AND SHALL HAVE APPROPRIATE LABELING. ALL BUSSING SHALL BE SOLID COPPER. ON ALL 20 AMP BRANCH CIRCUITS, CONDUCTORS LARGER THAN #10 AWG SHALL BE REDUCED TO #10 AWG WITHIN 10 FEET OF PANELBOARD AND DEVICES IN JUNCTION BOXES ON RATED TERMINAL STRIPS. T. PANELBOARD FOR USE ON 208Y/120V VOLT SYSTEM SHALL HAVE A MINIMUM INTEGRATED EQUIPMENT SHORT CIRCUIT CURRENT RATING OF 10,000 AMPS RMS SYMMETRICAL. EXACT RATING SHALL BE DETERMINED BY AVAILABLE FAULT CURRENT FROM UTILITY. GENERAL CONTRACTOR SHALL FURNISH PANELS BASED ON UTILITY COMPANY INFORMATION. ALL LUG CONNECTIONS SHALL BE 75 DEGREE RATED. U. PANELBOARD FRONT ASSEMBLY SHALL INCLUDE A HINGED DOOR WITH A FLUSH MOUNTED CYLINDER LOCK TYPE SPRING LOADED LATCH. ALL LOCKS SHALL BE KEYED ALIKE. DOOR SHALL INCLUDE A TYPED CIRCUIT DIRECTORY CARD MOUNTED IN A FRAME WITH A CLEAR PLASTIC PROTECTIVE COVER. V. PANELBOARD SHALL HAVE A FULL CAPACITY SOLID COPPER NEUTRAL SUBASSEMBLY. W. PANELBOARD SHALL INCLUDE A SOLID COPPER GROUND BUS SUBASSEMBLY, SIMILAR IN CONSTRUCTION TO THE NEUTRAL SUBASSEMBLY, FACTORY MOUNTED AND BONDED TO THE BOX. X. PANELBOARD SHALL INCLUDE (WHERE SPECIFIED) A SOLID COPPER ISOLATED GROUND BUS SUBASSEMBLY, SIMILAR IN CONSTRUCTION TO THE NEUTRAL SUBASSEMBLY, FACTORY SUPPLIED FIELD INSTALLED. Y. INTERIOR LABELING SHALL INCLUDE A CONNECTION DIAGRAM AND LABELS INDICATING PROPER TORQUE AND WIRE TYPES FOR MAIN INPUT CONNECTIONS AND BOTH LINE AND LOAD SIDE CIRCUIT BREAKER CONNECTIONS. Z. CIRCUIT BREAKERS SHALL BE QUICK MAKE, QUICK BREAK, THERMAL MAGNETIC TRIP (ENCLOSURE COMPENSATED), MOLDED CASE TYPE, UL LISTED. 15 AND 20 AMP SINGLE POLE BREAKERS SHALL CARRY THE UL "SWD" MARKING. LINE SIDE TERMINALS SHALL BE BOLTED TO MAIN BUSBARS. BREAKER RATINGS SHALL BE PER DRAWINGS. PHASE A PHASE B PHASE C NEUTRAL GROUND ISOLATED GROUND BLACK RED BLUE WHITE GREEN GREEN/ YELLOW STRIPE CIRCUIT BREAKER/FUSE AND WIRE SIZE COMBINATIONS NOT SHOWN ABOVE SHALL BE APPROVED BY THE ENGINEER PRIOR TO INSTALLATION. 26 05 26 GROUNDING AND BONDING A. FURNISH AND INSTALL A COMPLETE GROUNDING SYSTEM IN COMPLIANCE WITH ALL REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE. B. A SEPARATE EQUIPMENT GROUNDING CONDUCTOR, MINIMUM SIZE PER NEC TABLE 250.122, SHALL BE INSTALLED IN CONDUIT ALONG WITH ALL FEEDERS, BRANCH CIRCUITS AND CONTROL CIRCUITS. CONDUCTOR INSULATION SHALL BE GREEN. C. CONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS. ALL ENCLOSURES AND NON-CURRENT CARRYING METALS TO BE GROUNDED. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON-CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. ALL RECEPTACLES SHALL BE BONDED TO A GROUND CONDUCTOR USING A #12 AWG MINIMUM BONDING JUMPER BETWEEN RECEPTACLE TERMINAL AND GROUND CONDUCTOR. METAL-TO-METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. BOND ALL STRUCTURAL STEEL TO EARTH, GROUND RODS OR PLATES, OR WATER SYSTEM. H. BOND ALL ROOF MOUNTED EQUIPMENT TO ACCEPTABLE GROUNDS PER THE N.E.C. AC. MANUFACTURER: GENERAL ELECTRIC TYPE AQ FOR 208Y/120V APPLICATIONS. EQUAL EQUIPMENT BY SQUARE D, SIEMENS, OR CUTLER HAMMER WILL BE ACCEPTED. AF. TEST AND MAKE CORRECTIONS/ADJUSTMENTS FOR PHASE BALANCING. (ELECTRICAL SPECIFICATIONS CONTINUED ON SHEET E-702) ALL CONDUCTORS SHALL BE COPPER. ALUMINUM CONDUCTORS ARE C. COORDINATE WORK PROVIDED BY LANDLORD PRIOR TO BID AND INCLUDE THE COST OF ANY SUCH WORK AS DIRECTED BY LANDLORD. WIRING OF METERING EQUIPMENT SHALL BE BY GENERAL CONTRACTOR AS DIRECTED BY THE ELECTRIC COMPANY. D. METERING EQUIPMENT SHALL BE FURNISHED BY GENERAL CONTRACTOR AND INSTALLED TO THE MALLS REQUIREMENTS. E. DISCONNECT SWITCHES SHALL BE HEAVY-DUTY TYPE, UL LISTED. 8 9 SGH STORE #: 6078 DRAWN BY: EDS PERMITTED. 10 SUNGLASS HUT LA PLAZA MALL 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM GENERAL CONTRACTOR SHALL FURNISH ALL LABOR, MISC. MATERIALS AND EQUIPMENT NECESSARY TO INSTALL ALL OF THE ELECTRICAL SERVICE FROM THE LANDLORD'S ELECTRICAL SERVICE ROOM INCLUDING (AS INDICATED ON SHEET E4.0) BUT NOT LIMITED TO THE SECONDARY CABLES, CONDUIT, PULL WIRE AND GROUND ROD AND SLEEVE AS REQUIRED. COORDINATE REQUIREMENTS WITH LANDLORD PRIOR TO BID. THE GENERAL CONTRACTOR SHALL COORDINATE INSTALLATION OF THE DISCONNECT SWITCHES AND PANELBOARD WITH THIS WORK. B. SEAL AB. NAMEPLATES AS SCHEDULED ON DRAWINGS SHALL INDICATE FUNCTION OF EACH DEVICE. NAMEPLATES SHALL BE LAMINATED PHENOLIC WITH A WHITE SURFACE AND BLACK CORE. USE 1/16" THICK MATERIAL FOR PLATES UP TO 2" X 4". FOR LARGER SIZES, USE 1/8" THICK MATERIAL 26 05 29 DISTRIBUTION A. Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com TX Registration Number: #F-9566 AA. TERMINALS FOR CONNECTION OF THE FEEDER TO THE PANELBOARD MAINS TO MAIN BREAKER SHALL BE UL RECOGNIZED AS SUITABLE FOR THE TYPE OF CONDUCTORS SPECIFIED. AD. PANELBOARD SHALL BE INSTALLED WITH TOP CIRCUIT BREAKER AT 6'-0" ABOVE FLOOR, FLUSH OR THE GROUNDING ELECTRODE CONDUCTOR FOR SEPARATELY DERIVED SYSTEMS, SUCH AS SURFACE MOUNTED. DRY-TYPE TRANSFORMERS, SHALL BE RUN IN NON-METALLIC (PVC) CONDUIT TO MINIMIZE GROUND IMPEDANCE. AE. ALL CONNECTIONS AT PANEL AND SWITCHES ARE TO BE MADE, ALL SPLICES COMPLETE, ALL FUSES IN PLACE, AND ALL CIRCUITS CONTINUOUS FROM POINT OF SERVICE CONNECTION TO IT'S LIGHTING FIXTURES SHALL BE GROUNDED BY THE USE OF A PIGTAIL FASTENED ON BARE METAL FINAL DESTINATION, AND ALL COVERS AND PLATES INSTALLED AND FINAL ELECTRICAL INSPECTION THAT IS FREE OF PAINT. PRIOR TO THE TIME OF FINAL INSPECTION BY OWNER CONSTRUCTION MANAGER. G. CONSULTANT PROJECT # 150343 CONTROL FUSES FOR MOTOR STARTERS, CONTACTORS, AND CONTROL PANEL TRANSFORMERS SHALL BE BUSSMANN FNQ-R SIZED AT 500% RATED CURRENT. CONDUCTORS USED FOR EMERGENCY LIGHTING CIRCUITS SHALL BE #10 AWG, MINIMUM, AND SHALL BE RUN IN SEPARATE CONDUIT USED FOR NO OTHER PURPOSE. PERMITTED. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 SWITCHES SHALL BE RATED FOR AC. FUSIBLE SWITCHES MUST ACCEPT CLASS R FUSES AND HAVE PROVISIONS TO REJECT ALL FUSES EXCEPT CLASS R. THE UL LISTED SHORT CIRCUIT RATING OF THE SWITCHES SHALL BE 200,000 RMS SYMMETRICAL AMPERES WHEN CLASS R FUSES ARE USED. TYPED LIST OF ALL SPARES SHALL ALSO BE INCLUDED. THE FOLLOWING COLOR CODE SHALL BE USED: F. ALL SWITCHES SHALL HAVE SWITCH BLADES WHICH ARE FULLY VISIBLE IN THE "OFF" POSITION WHEN THE SWITCH DOOR IS OPEN. SWITCHES SHALL HAVE REMOVABLE ARC SUPPRESSORS WHERE NECESSARY TO PERMIT EASY ACCESS TO LINE SIDE LUGS. LUGS SHALL BE FRONT REMOVABLE AND UL LISTED FOR 75 DEGREES C., ALUMINUM OR COPPER WIRES. Q. C. E. DISCONNECT SWITCHES SHALL BE BY SQUARE D, SIEMENS, CUTLER HAMMER, OR GENERAL ELECTRIC. FURNISH SPARE FUSES TO THE TENANT IN THE FOLLOWING QUANTITIES: 10% OF TOTAL PROJECT QUANTITY (BUT NOT LESS THAN THREE (3) FOR EACH TYPE AND RATING OF FUSES). ALUMINUM CONDUCTORS ARE D. 14 P. B. D. 13 NAMEPLATES SHALL INDICATE FUNCTION OF EACH DEVICE. NAMEPLATES SHALL BE LAMINATED PHENOLIC WITH A WHITE SURFACE AND BLACK CORE. USE 1/16" THICK MATERIAL FOR NAMEPLATES UP TO 2"x4" AND USE 1/8" THICK MATERIAL FOR LARGER SIZES. ALL NAMEPLATES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. GENERAL CONTRACTOR TO COORDINATE WITH THE LOCAL BUILDING AUTHORITY OR BUILDING INSPECTOR ON WHICH ITEMS SHOULD HAVE A NAMEPLATE. MINIMUM WIRE SIZES FOR 20A BRANCH CIRCUITS SHALL BE ADJUSTED FOR DISTANCE, MEASURED FROM THE PANELBOARD CIRCUIT BREAKER TO THE FURTHEST OUTLET, O. AS FOLLOWS: LESS THAN 100 FT - #12 BETWEEN 101 AND 150 FEET - #10 BETWEEN 151 AND 250 FEET - #8 OVER 251 FEET - #6 12 K. CONDUCTORS SHALL BE COPPER. UNLESS NOTED OTHERWISE ON THE DRAWINGS, THE MINIMUM COPPER WIRE SIZES FOR WET AND DRY AREAS AS DEFINED BY THE N.E.C. SHALL BE AS FOLLOWS: 20 AMP CKT BKR OR FUSE = #12 AWG, THHN/THWN 30 AMP CKT BKR OR FUSE = #10 AWG, THHN/THWN 40 AMP CKT BKR OR FUSE = #8 AWG, THHN/THWN 50 AMP CKT BKR OR FUSE = #8 AWG, THHN/THWN 100 AMP CKT BKR OR FUSE = #3 AWG, THHN/THWN 125 AMP CKT BKR OR FUSE = #1 AWG, THHN/THWN 200 AMP CKT BKR OR FUSE = #3/0 AWG, THHN/THWN PROVIDE INSTRUCTION TO TENANT'S OPERATING PERSONNEL AS NECESSARY, SHOWING LOCATIONS AND PROPER OPERATION OF MAJOR ITEMS OF EQUIPMENT AND SYSTEM COMPONENTS AND REFERRING TO THE OPERATING INSTRUCTION MANUAL DESCRIBED BELOW AS A GUIDE. AJ. GENERAL CONTRACTOR SHALL GUARANTEE THIS WORKMANSHIP AND MATERIALS, EXCEPT FOR TENANT-SUPPLIED MATERIALS, FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY TENANT'S CONSTRUCTION MANAGER/ENGINEERING MANAGER AND LEAVE THIS WORK IN PERFECT ORDER AT COMPLETION. 9 F. AL. COMPILE TWO (2) WRITTEN MANUALS OF OPERATING INSTRUCTIONS INCLUDING COPIES OF SHOP DRAWINGS AND A LISTING OF EQUIPMENT SUPPLIERS. ASSEMBLE IN 8-1/2" X 11" HARD BACKED INDEXED BINDER. MATERIAL SHALL BE AS FOLLOWS: GENERAL CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. AF. THE MATERIALS AND EQUIPMENT INSTALLED IN THE WORK SHALL MEET THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. ALL ELECTRICAL WORK SHALL BE INSPECTED BY THE GOVERNMENTAL AGENCY HAVING JURISDICTION, INCLUDING LOCAL INSPECTION AUTHORITIES. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK. COORDINATE ANY EXISTING EQUIPMENT TO BE LEFT INTACT AND ADVISE TENANT'S CONSTRUCTION MANAGER AT TIME OF BID. AE. AT COMPLETION OF PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY OF DRAWINGS STAMPED "DO NOT REMOVE" SHALL BE PLACED IN DRAWING TUBE LOCATED NEXT TO THE ELECTRICAL PANELS (SEE ARCHITECTURAL DRAWINGS FOR LOCATION). A SECOND AS-BUILT SET SHALL BE SENT TO OWNER OFFICES. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES, THE LANDLORD OR TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MOST STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS NOTED OTHERWISE. N. 8 FOR ANY PHASED STORE CONSTRUCTION, THIS CONTRACTOR IS TO INCLUDE IN THIS BID ALL NECESSARY ELECTRICAL SERVICE CHANGES REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE'S ELECTRIC SERVICE IN OPERATION. CONTRACTOR MUST SCHEDULE WITH TENANT'S CONSTRUCTION MANAGER AND LANDLORD (IN WRITING) ONE WEEK PRIOR TO ANY SHUT DOWN OF THE P.O.S., CASH REGISTERS, ELECTRICAL, TELEPHONE OR FIRE ALARM SYSTEMS. ADVISE GENERAL CONTRACTOR AND TENANT AT TIME OF BID IF ANY CONFLICTS EXIST. AD. GENERAL CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: 1. LOCATION OF JUNCTION BOXES AND RECEPTACLES. 2. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. 3. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. GENERAL CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY TENANT TO THE CONTRACTOR. ALL PERMITS REQUIRED BY LAWS, ORDINANCES AND BUILDING CODES HAVING JURISDICTION SHALL BE OBTAINED AT PROPER TIME BY AND AT THE EXPENSE OF THE GENERAL CONTRACTOR. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO TENANT'S CONSTRUCTION MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW SEVEN (7) WORKING DAYS FOR TENANT'S CONSTRUCTION MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL CONTRACTOR AND/OR SUB-CONTRACTOR SHOWING THAT THEY HAVE REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. AC. THE ARCHITECT RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ANY ITEM WHICH, IN THEIR OPINION, SHALL NOT PRESENT AN ORDERLY OR REASONABLY NEAT OR WORKMANLIKE APPEARANCE, PROVIDED THAT SUCH ITEM CAN BE PROPERLY INSTALLED IN SUCH ORDERLY WAY BY METHODS USUAL IN SUCH WORK, OR WHICH DOES NOT COMPLY WITH CONTRACT DRAWINGS OR SPECIFICATIONS. SUCH REMOVALS OR REPLACEMENTS SHALL BE DONE BY CONTRACTOR WHEN SO DIRECTED IN WRITING BY ARCHITECT AND AT CONTRACTOR'S EXPENSE. THE NATIONAL ELECTRICAL CODE. STATE, CITY, AND COUNTY BUILDING CODES AND ORDINANCES. NATIONAL BOARD OF FIRE UNDERWRITERS. CERTAIN CODES AND STANDARDS AS SET UP BY VARIOUS TECHNICAL SOCIETIES SUCH AS UL, NEMA, NECA, IEEE, ASTM, IES, IPCEA, AND ANSI. THIS WORK SHALL BE GOVERNED ALSO BY LOCAL INSPECTOR'S REQUIREMENTS. FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT STANDARDS. AMERICANS WITH DISABILITIES ACT. M. 7 AB. ELECTRICAL DRAWINGS ARE INTENDED TO INDICATE APPROXIMATE LOCATIONS OF SWITCHES, RECEPTACLES, LIGHTING FIXTURES AND OTHER ITEMS OF VARIOUS ELECTRICAL SYSTEMS OF PROJECT. EXACT LOCATIONS AND ROUGH-IN DIMENSIONS FOR ALL WORK AND EQUIPMENT SHALL BE OBTAINED FROM ARCHITECT OR ARCHITECT'S REPRESENTATIVE AS WORK PROGRESSES. SHOULD THE GENERAL CONTRACTOR FAIL TO PROPERLY OBTAIN SUCH LOCATIONS OR DIMENSIONS, THE ARCHITECT SHALL CHANGE THIS WORK AT THE GENERAL CONTRACTORS EXPENSE WHEN REQUESTED BY ARCHITECT. ARCHITECT RESERVES THE RIGHT TO MAKE MINOR CHANGES IN LOCATION OF ELECTRICAL WORK OR EQUIPMENT PRIOR TO ROUGHING IN WITH NO ADDITIONAL COST TO TENANT. TENANT'S CONSTRUCTION MANAGER RESERVES THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. ALL WORK SHALL BE DONE IN ACCORDANCE WITH: 1. 2. 3. 4. J. S. 6 AA. ELECTRICAL LAYOUTS ARE SCHEMATIC. EXACT LOCATIONS ARE DETERMINED BY EXACT LOCATION OF EQUIPMENT, ETC., AND MAY BE REVISED TO SUIT THE CONSTRUCTION CONDITIONS AND AID IN COORDINATION WITH WORK OF OTHER CONTRACTORS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE TENANT'S CONSTRUCTION MANAGER IN WRITING OF ANY VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF THE BID. OTHERWISE, TENANT'S CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. GENERAL CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY TENANT'S CONSTRUCTION MANAGER AND THE LANDLORD. PATCHING IS TO BE "AS NEW CONDITION". G. C A TEMPERATURE CONTROL WIRING THAT IS FURNISHED BY OTHERS PRE-WIRED IN UNITS. TELEPHONES AND FINAL CONNECTION OF WIRING THERETO. INTERNAL WIRING OF EQUIPMENT FURNISHED AND PRE-WIRED BY OTHERS. SECURITY SYSTEM FURNISHED AND INSTALLED BY SECURITY CONTRACTOR. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. I. R. T. TEMPORARY SERVICE AS REQUIRED. PRIMARY DISTRIBUTION BY ELECTRIC COMPANY. EMERGENCY AND EXIT LIGHTING SYSTEMS. CONDUIT AND CABLES FOR TELEPHONE AND DATA SYSTEMS AS SHOWN ON THE DRAWINGS. ELECTRICAL PANEL AND BRANCH CIRCUIT WIRING. WIRING DEVICES AND PLATES. LIGHTING FIXTURES AND LAMPS, INSTALLATION AND WIRING. LIGHTING CONTROLS. ELECTRICAL CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS, SIGNS, CORNICE LIGHTING, CASE LIGHTING, ETC., AS SHOWN ON DRAWINGS. INSTALLATION OF CONDUIT AND CABLES FOR SOUND SYSTEM AS SHOWN ON DRAWINGS. SMOKE/FIRE ALARM WIRING, DEVICES AND CONDUIT, AS SHOWN OR DESCRIBED ON DRAWINGS OR AS NECESSARY TO MEET LANDLORD, STATE, LOCAL, INSURANCE AND FIRE DEPARTMENT REQUIREMENTS. INSTALLATION OF CONDUITS STUBBED TO ABOVE CEILING FOR HVAC. ALSO, ANY ADDITIONAL CONDUIT FOR HVAC CONTROL EQUIPMENT WHERE PLENUM RATED CABLES ARE NOT PERMITTED. THE GENERAL CONTRACTOR SHALL PAY FOR ALL ELECTRICITY PRIOR TO STORE MERCHANDISING, AND INCLUDE COST IN BID. F. D Q. WORK WHICH SHALL BE PERFORMED BY OTHERS, UNLESS NOTED OTHERWISE, INCLUDES THE FOLLOWING: 1. 2. 3. 4. D. ANY REFERENCE TO TENANT OR TENANT'S CONSTRUCTION MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO SUNGLASS HUT. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATIONS SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 26 THROUGH 28. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF THE SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK AND THE WORK OF THE SUBCONTRACTORS TO COMPLY WITH THE OWNER SCHEDULE AND THE PROJECT COMPLETION DATE. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTOR'S BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. REFER TO RESPONSIBILITY SCHEDULE ON THE ARCHITECTURAL DRAWINGS FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL NEW COMPLETE ELECTRICAL SYSTEM AS INDICATED ON DRAWINGS, AS REQUIRED BY CODE AND AS SPECIFIED HEREIN, IN DIVISIONS 26, 27, AND 28. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING: 1. 2. 3. 4. 5. 6. 7. 8. 9. H 5 LA PLAZA MALL 2 AT 1 REVIEWED BY: KAH AUTHORIZED FOR: ELECTRICAL SPECIFICATIONS 11 12 13 14 3 B. 26 05 33 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS A. K B. J D. RECESSED OUTLET BOXES SHALL BE STAMPED STEEL SUITABLE FOR THE DEVICE INSTALLED. SURFACE MOUNTED OUTLET BOXES SHALL BE CAST IRON SUITABLE FOR THE DEVICE INSTALLED. F. RACEWAY AND ENCLOSURE SIZES SHALL BE AS SHOWN ON DRAWINGS OR, IF NOT SHOWN, SHALL BE SIZED TO COMPLY WITH N.E.C. FILL REQUIREMENTS FOR CONDUCTORS ENCLOSED. J. G K. L. M. F N. O. P. E USER: JGRAY PLOTTED: 7/16/2015 - 4:04 PM P:\SGH\150343 SGH-La Plaza Mall Mcallen, TX\E-701_06078.dwg LAYOUT: E-702 (208v) Q. D R. S. T. C U. B B. SINGLE POLE SWITCHES: 20AMP - 120-277V: HUBBELL "HBL1221PL" DOUBLE POLE SWITCHES: 20AMP - 120-277V: HUBBELL "HBL1222PL" DUPLEX RECEPTACLES: 20AMP - 125V: HUBBELL "HBL5362" DUPLEX RECEPTACLES - BLACK: 20AMP - 125V: HUBBELL "HBL5362BLK" ISOLATED GROUND RECEPTACLES: 20AMP - 125V: HUBBELL "IG5362" GFCI RECEPTACLES: 20AMP - 125V: HUBBELL "GF5362A" FLOOR BOX - MODEL S1PFB NON-METALLIC ROUND FLOOR BOX POKE-THRU - MODEL S1PTFIT THRU-FLOOR FITTING (DUAL CHANNEL) SUB PLATE - MODEL S1SP SUB-PLATE(STYLE LINE/GFCI) COVER - MODEL S1TFCAL (ALUMINUM FINISH). ALL DEVICE COVER PLATES SHALL BE PASS AND SEYMOUR SERIES "RP" OR EQUAL BY EAGLE ELECTRIC MFG. CO. OTHER EQUIVALENT DEVICES WITH MATCHING COVER PLATES MAY BE FURNISHED AS APPROVED BY OWNER. FLEXIBLE METAL CONDUIT (FMC) SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND E. AS THE FINAL CONNECTION TO RECESSED FIXTURES, MOTORS, AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. FMC SHALL BE UL APPROVED, AND BOTH THE CONDUIT AND FITTINGS SHALL BE LISTED FOR GROUNDING. FMC SHALL BE KEPT TO SIX FEET (6'-0") MAXIMUM LENGTH AND SHALL BE MINIMUM ONE-HALF INCH (1/2") ELECTRICAL TRADE SIZE. WHEN CONNECTED TO HARD CONDUIT, THE FMC MUST BE THE SAME SIZE AS THE HARD F. CONDUIT IT IS CONNECTED TO. AN EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED IN ALL RUNS OF FMC. LIQUID-TIGHT FLEXIBLE METAL CONDUIT (LFMC) AND LIQUID-TIGHT FITTINGS SHALL BE USED IN AREAS EXPOSED TO THE WEATHER OR EXCESSIVE MOISTURE AS THE FINAL CONNECTION TO MOTORS, AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. LFMC SHALL BE UL APPROVED, AND BOTH THE CONDUIT AND FITTINGS SHALL BE LISTED FOR GROUNDING. LFMC SHALL BE KEPT TO SIX FEET (6'-0") MAXIMUM LENGTH AND SHALL BE MINIMUM ONE-HALF INCH (1/2") ELECTRICAL TRADE SIZE. WHEN CONNECTED TO HARD CONDUIT, THE LFMC MUST BE THE SAME SIZE AS THE HARD CONDUIT IT IS CONNECTED TO. AN EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED IN ALL RUNS OF LFMC. CONDUIT SHALL GENERALLY BE CONCEALED WHERE POSSIBLE. NO CONDUIT SHALL BE RUN IN SLAB, EXCEPT AS REQUIRED FOR FLOOR-MOUNTED DEVICES. PROVIDE PROPERLY LABELED PULL STRING IN ALL EMPTY CONDUITS. ALL CONDUIT FITTINGS SHALL BE GALVANIZED MALLEABLE IRON OR STEEL. CONNECTORS AND COUPLINGS SHALL BE THREADED OR CUPPED SET SCREW TYPE, CONCRETE TIGHT. CONDUIT BODIES SHALL BE MALLEABLE IRON, THREADED FOR HEAVYWALL CONDUIT AND CUPPED SET SCREW TYPE FOR EMT, WITH CADMIUM FINISH AND CADMIUM PLATED SHEET STEEL COVERS. SYNTHETIC RUBBER GASKETS SHALL BE USED UNDER BODY COVERS EXPOSED TO WEATHER. EMT CONNECTORS SHALL BE INSULATED THROAT TYPE. INSTALL EXPANSION FITTINGS AT ALL LOCATIONS WHERE CONDUITS CROSS BUILDING EXPANSION JOINTS OR TRAVERSE FROM ONE INDEPENDENT STRUCTURE TO ANOTHER. INSTALL WHEREVER CONDUITS TRAVERSE STRUCTURES HAVING SEPARATE FOUNDATIONS OR WHERE EXISTING BUILDINGS ARE JOINED TO A NEW STRUCTURE. DURING ROUGHING-IN, CAP ALL CONDUITS WHICH MAY BECOME FOULED WITH FOREIGN MATERIAL. W. NO MORE THAN THREE (3) 90 DEGREE BENDS WILL BE ALLOWED IN ANY ONE CONDUIT RUN. WHERE MORE BENDS ARE NECESSARY IN ANY SINGLE RUN, A PULL BOX SHALL BE INSTALLED. ALL CONDUIT EXCEPT IN CONCRETE SLAB OR EARTH SHALL BE ROUTED PARALLEL OR PERPENDICULAR TO THE LINES OF THE BUILDING, AND NO OUT-OF-PLUMB OR DIAGONAL LINES WILL BE ACCEPTED. 26 09 23 LIGHTING CONTROLS 1 2 3 FURNISH AND INSTALL CONTACTORS, CONTROL RELAYS, PUSHBUTTON STATIONS, SELECTOR SWITCHES, PILOT LIGHTS, FUSES AND SIMILAR CONTROL AUXILIARIES AS SHOWN ON DRAWINGS AND/OR REQUIRED TO PROVIDE PROPER CONTROL AND ISOLATION BETWEEN VARIOUS AUTOMATIC CONTROLLERS AND EQUIPMENT SHOWN ON THE DRAWINGS. ALL CIRCUIT BREAKERS FEEDING MOTOR LOADS SHALL BE HACR TYPE. H. EQUIPMENT SHALL BE SAME MAKE AS MOTOR STARTERS. PUSHBUTTON STATIONS, SELECTOR SWITCHES, PILOT LIGHTS: HEAVY DUTY, OIL TIGHT, STANDARD SIZE, WITH TRANSFORMER TYPE PILOT LIGHTS, FLUSH MOUNTED WHERE PRACTICAL. I. ALL OVERLOAD DEVICES, INCLUDING EQUIPMENT FURNISHED UNDER OTHER CONTRACTS, SHALL BE SET AND ADJUSTED TO SUIT THE LOAD CONDITIONS. C. INSTALL LIGHTING FIXTURES AS SHOWN ON THE DRAWINGS. LAMPS SHALL BE MANUFACTURED BY PHILIPS, OSRAM/SYLVANIA OR GENERAL ELECTRIC. ALL LAMP TYPES SHALL BE BY THE SAME MANUFACTURER. D. FIXTURES ARE TO BE PROVIDED COMPLETE WITH BALLASTS, SOCKET, LAMPS, END AND TRIP PLATES AND ALL MOUNTING ACCESSORIES REQUIRED FOR A COMPLETE FIXTURE INSTALLATION. E. INCANDESCENT AND HIGH INTENSITY DISCHARGE RECESSED LIGHTING FIXTURES TO BE FURNISHED WITH THERMAL CUT OUTS AS REQUIRED BY THE NEC. F. USE RAPID-START HIGH-POWER-FACTOR ELECTRONIC BALLASTS AND T8 LAMPS, UNLESS NOTED OTHERWISE. FURNISH SPECIAL LOW TEMPERATURE BALLASTS FOR EXTERIOR MOUNTED FIXTURES. G. UNLESS OTHERWISE NOTED, ALL LENSES ON FLUORESCENT FIXTURES ARE TO BE ACRYLIC AND A MINIMUM OF 0.125 IN. THICK. H. ALL RECESSED HID FIXTURES SHALL CARRY A ULR LISTING. THEY SHALL HAVE A THERMAL CUT OUT ON BOTH THE BALLAST AND THE FIXTURE ITSELF. I. USE STEEL WIRE HANGERS FASTENED TO THE BUILDING STRUCTURE TO SUPPORT RECESSED FIXTURES AT EACH CORNER. (FOUR CORNER SUSPENDED). FIXTURES TO FIT TIGHT AGAINST CONSTRUCTION TO ELIMINATE LIGHT LEAKS. 4 WALL-MOUNTED FIXTURES SHALL BE MOUNTED PLUMB WITH BUILDING LINES AND INSTALLED WITH PROPER BOX AND COVER HARDWARE. SURFACE-MOUNTED FIXTURES SHALL COVER MOUNTING HARDWARE. USE A CANOPY THAT IS NO LONGER THAN THE LENGTH AND WIDTH OF THE FIXTURE AND AT A HEIGHT THAT IS NO HIGHER THAN REQUIRED TO MOUNT FIXTURE ABSOLUTELY VERTICAL. CANOPY FINISH SHALL MATCH FIXTURE FINISH. 11 F. ALL NEW MATERIAL AND EQUIPMENT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS: TELECOMMUNICATIONS INDUSTRY ASSOC./ELECTRONIC INDUSTRIES ALLIANCE (TIA/EIA): a. TIA/EIA 568A.1, 2, AND 3 TELECOMMUNICATION CABLING STANDARD. b. TIA/EIA 569 TELECOMMUNICATION PATHWAYS AND SPACES. c. TIA/EIA 606 ADMINISTRATION OF INFRASTRUCTURE d. TIA/EIA 607 GROUNDING AND BONDING e. COMPLY WITH TIA/EIA 568, 569, AND BIC STANDARDS. f. COMPLY WITH NFPA 70. 12 13 14 WIRING METHOD: INSTALL HORIZONTAL CABLING IN RACEWAY WITHIN RACKS AND ENCLOSURES, AND EXCEPT IN ACCESSIBLE CEILING SPACES AND IN GYPSUM BOARD PARTITIONS WHERE CABLE WIRING METHOD MAY BE USED. CONCEAL RACEWAY AND CABLING EXCEPT IN UNFINISHED SPACES. IN ACCESSIBLE CEILINGS, USE APPROPRIATELY SIZED J-HOOKS TO SUPPORT THE CABLING EVERY FOUR FEET (MAXIMUM). G. INSTALL CABLE USING TECHNIQUES, PRACTICES, AND METHODS THAT ARE CONSISTENT WITH CATEGORY 6 RATING OF COMPONENTS AND THAT INSURE CATEGORY 6 PERFORMANCE OF COMPLETED AND LINKED SIGNAL PATHS, END TO END. H. DO NOT BEND CABLE IN HANDLING OR IN INSTALLING TO SMALLER RADII THAN MINIMUMS RECOMMENDED BY MANUFACTURER. I. HORIZONTAL CABLES: LABEL CABLES AT THE WORK AREA END AND AT THE CLOSET END WITH THE PATCH PANEL PORT NUMBER. LABEL EACH CABLE WITHIN 3 INCHES OF EACH TERMINATION, WHERE IT IS ACCESSIBLE IN A CABINET OR JUNCTION OR OUTLET BOX, AND ELSEWHERE AS INDICATED. D. THE CONTRACTOR SHALL BEAR ALL COSTS OF PERMITS, INSPECTIONS TESTS, AND/OR APPROVALS. WORKSTATION: LABEL CABLES WITHIN OUTLET BOXES AND NEATLY TYPED ON THE INTEGRAL LABEL IN THE FACEPLATE WITH THE PATCH PANEL PORT NUMBER. K. E. THE CONTRACTOR SHALL PROVIDE ON-SITE PERSONNEL TO TROUBLESHOOT AND REPAIR ANY PROBLEMS THAT ARISE DURING CUTOVER AS THEY RELATE TO THEIR INSTALLED SYSTEM. WARRANTY PERIOD FOR COMMUNICATIONS CONNECTIVITY (INCLUDING ALL COPPER): MANUFACTURER'S STANDARD, BUT NOT LESS THAN 25 YEARS FROM DATE OF CONTRACT COMPLETION. F. AFTER COMPLETION, A WARRANTY SHALL BE FURNISHED FOR ALL COMPONENTS, PARTS, AND ASSEMBLIES AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. WARRANTY SERVICES SHALL BE PROVIDED BY A CERTIFIED, FACTORY TRAINED REPRESENTATIVE OF THE EQUIPMENT MANUFACTURER FOR A MINIMUM OF ONE YEAR OR AS SPECIFIED IN EACH INDIVIDUAL SECTION. 27 05 10 TELEPHONE AND DATA CONDUIT SYSTEM 23 31 11 DIGITAL ADDRESSABLE FIRE ALARM SYSTEM 6 7 Shremshock Engineering, Inc. 7400 W. Campus Rd. Suite 150 New Albany, OH 43054 t: 614 545 4550 | f: 614 545 4555 | shremshock.com TX Registration Number: #F-9566 SEAL A. INSTALLATION OF FIRE ALARM SYSTEM SHALL BE UNDER A SEPARATE PERMIT. ALL REQUIRED FIRE ALARM DEVICES, CONDUITS, WIRES, BACKBOXES, ETC. SHALL BE INSTALLED AT TENANT CONTRACTOR'S EXPENSE UNDER A SEPARATE PERMIT BY MALL FIRE/LIFE SAFETY CONTRACTOR. INDICATE ON PLANS THAT IF REQUIRED, A VARIANCE WILL BE PROVIDED. (END OF ELECTRICAL SPECIFICATIONS) A. FURNISH AND INSTALL A SYSTEM OF CONDUIT RACEWAYS, OUTLET BOXES, PULL WIRES, AND TERMINAL BOARDS AS SHOWN ON THE DRAWINGS UNLESS OTHERWISE NOTED ON PLANS. TELEPHONE SWITCHING APPARATUS, CONDUCTORS, INSTRUMENTS, MISCELLANEOUS EQUIPMENT AND APPURTENANCES ARE NOT PART OF THIS CONTRACT AND WILL BE PROVIDED AND INSTALLED BY OTHERS. B. CONDUITS FOR TELEPHONE WALL OUTLETS AND DATA WIRING SHALL BE A MINIMUM OF 1" UNLESS NOTED OTHERWISE. C. FURNISH AND INSTALL A 3/4" THICK, FIRE-TREATED, PLYWOOD TELECOM BACKBOARD AT LOCATION SHOWN ON THE DRAWINGS. PAINT WITH FIRE RETARDANT "P-1B" OR AS DIRECTED BY TENANT'S CONSTRUCTION MANAGER. THE PLYWOOD BACKBOARD SHALL BE SECURELY ATTACHED TO THE BUILDING WALLS TO SUPPORT RELAY PANEL, TERMINAL BLOCKS AND OTHER HARDWARE WEIGHING APPROXIMATELY 10 POUNDS PER SQUARE FOOT. D. ALL CONDUIT RUNS FOR DATA AND TELEPHONE SHALL BE CONTINUOUS WITH NO JUNCTION BOXES EXCEPT AS NOTED ON DRAWINGS. THIS INCLUDES BUT IS NOT LIMITED TO RUNS BETWEEN TELEPHONE BOARD, MANAGER'S OFFICE, SOUND SYSTEM, CASHWRAPS AND TELEPHONE SETS. E. INSTALL PULL STRING IN EMPTY CONDUITS. ALL CONDUITS SHALL BE LABELED FOR PURPOSE DESIGNATED. F. FURNISH AND INSTALL GROUND ROD AND #6 GROUND WIRE FROM TELECOM BACKBOARD TO SERVICE ENTRANCE GROUND AND GROUND ROD PER TELEPHONE COMPANY'S REQUIREMENTS. G. OUTLET BOXES TO BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. 27 05 15 INTERIOR COMMUNICATIONS PATHWAYS A. INTERIOR COMMUNICATIONS PATHWAYS SHALL BE INSTALLED BY THE GENERAL CONTRACTOR AND BY THE TELECOMMUNICATIONS CONTRACTOR AS SPECIFIED HEREIN. B. CONDUITS SHALL BE INSTALLED, AS DETAILED IN DRAWINGS. THESE CONDUITS SHALL BE INSTALLED BY THE GENERAL CONTRACTOR. 27 11 00 HORIZONTAL CABLING AND CONNECTIVITY A. PROVIDE A 10/100/1000 MBPS FULL-DUPLEX TRANSMISSION ETHERNET NETWORK OVER 4-PAIR, CATEGORY 6 UTP HORIZONTAL CABLING. THE SYSTEM SHALL BE A CERTIFIED SOLUTION BY THE CONNECTIVITY MANUFACTURER. THE HORIZONTAL INFRASTRUCTURE SHALL SUPPORT BOTH VOICE AND DATA APPLICATIONS. B. THIS SECTION INCLUDES WIRE, CABLE, CONNECTING DEVICES, INSTALLATION, AND TESTING FOR WIRING SYSTEMS TO BE USED AS SIGNAL PATHWAYS FOR VOICE, VIDEO, AND DATA TRANSMISSION. THE SYSTEM SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: 1. MOUNTING ELEMENTS 2. UNSHIELDED TWISTED-PAIR CABLE. 3. PATCH, STATION, AND CROSS CONNECT CORDS 4. JACKS AND FACEPLATES 5. TERMINATION AND PATCH PANELS C. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. 2. D. SUNGLASS HUT LA PLAZA MALL HORIZONTAL CABLES FOR VOICE/DATA/VIDEO INFRASTRUCTURE: 1. 2. 3. 4. 5. 6. E. COPPER CABLES (UTP): a. BERK-TEK, INC. b. BELDEN c. MOHAWK d. GENERAL e. UNIPRISE MODULAR JACKS AND FACEPLATES: a. LEVITON b. HUBBELL c. ORTRONICS d. PANDUIT e. UNIPRISE LISTED AS COMPLYING WITH CATEGORY 6 OF TIA/EIA. CONDUCTORS: SOLID COPPER. UTP CABLE: COMPLY WITH TIA/EIA. FOUR THERMOPLASTIC-INSULATED, INDIVIDUALLY TWISTED PAIR OF CONDUCTORS; NO. 2 AWG, COLOR-CODED; ENCLOSE IN A JACKET. CABLE RATING: PLENUM - LISTED FOR USE IN AIR-HANDLING SPACES, NON-PLENUM IN ALL OTHER AREAS. COLOR CODING: BLUE FOR DATA, YELLOW FOR VOICE AND WHITE FOR VIDEO 2200 S. 10TH STREET McALLEN, TX 78503 SPACE #Q14-C 2.0 TYPE: PREMIUM WORKSTATION OUTLETS: SINGLE JACK CONNECTOR ASSEMBLIES MOUNTED IN FACEPLATE. 1. 2. 3. 4. SGH STORE #: 6078 FACEPLATE: HIGH IMPACT PLASTIC; COLOR TO BE WHITE. MOUNTING: FLUSH, UNLESS OTHERWISE INDICATED. LABELING: SHALL HAVE INTEGRAL LABEL WITH LABEL COVER. JACK SPACES: AS INDICATED ON THE DRAWINGS WITH ANY NECESSARY BLANKS. BLANKS SHALL MATCH FACEPLATE COVER. DRAWN BY: EDS REVIEWED BY: KAH AUTHORIZED FOR: ELECTRICAL SPECIFICATIONS STEM-MOUNTED FIXTURES SHALL BE MOUNTED SO AS TO BE ABSOLUTELY VERTICAL AND HORIZONTAL. INSTALL AND SUPPORT AS SHOWN ON DRAWINGS. 5 A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 CONSULTANT PROJECT # 150343 J. ALL FIXTURES TO BE LISTED AND LABELED BY UNDERWRITERS LABORATORIES AND ALL BALLASTS TO BE CBM CERTIFIED BY ETL. C. L. 10 FURNISH NEW AND UN-DETERIORATED MATERIALS OF A QUALITY NOT LESS THAN WHAT IS SPECIFIED. ALL NEW MATERIAL SHALL HAVE MANUFACTURER'S NAME, MODEL NUMBER, OR OTHER IDENTIFICATION MARKING. 26 51 00 INTERIOR LIGHTING WHERE LIGHTING CONTACTORS ARE INDICATED ON THE DRAWINGS, THEY WILL BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR COMPLETE WITH CONDUIT. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE TO INSTALL THE CONTACTORS AND PULL ALL WIRES AS DETAILED ON THESE J. DRAWINGS AND CIRCUITED EXACTLY AS DIAGRAMMED ON THE ELECTRICAL DETAIL DRAWINGS. NO VARIATIONS TO THE CIRCUITING ARE ALLOWED. K. 26 27 26 WIRING DEVICES INSTALL ALL WIRING DEVICES, INCLUDING SWITCHES, RECEPTACLES AND POWER RECEPTACLES, TELEPHONE OUTLET BOXES, COVER PLATES AND BLANK OUTLET PLATES AS SHOWN OR DESCRIBED ON DRAWINGS. PROTECTIVE RELAYS SHALL HAVE ADJUSTABLE TIME DELAY RELAY IN CIRCUIT TO AVOID NUISANCE SHUT DOWNS. TIME MARK OR SIMILAR EQUIPMENT IS ACCEPTABLE, IF PROTECTION IS NOT PART OF STARTER. DO NOT RELY ON PROPERLY SIZED FUSES AND MOTOR STARTER OVERLOAD HEATERS ALONE TO AVOID SINGLE PHASING BURNOUTS. G. A. EXPOSED CONDUIT WILL BE PERMITTED IN ELECTRIC ROOMS, AND SIMILAR UNFINISHED SPACES, OVERHEAD IN AREAS WITHOUT CEILINGS AND ELSEWHERE AT THE DISCRETION OF THE ARCHITECT. B. 9 PROVIDE ALL MATERIALS, LABOR, TOOLS, TRANSPORTATION INCIDENTALS AND APPURTENANCES TO COMPLETE IN EVERY DETAIL AND LEAVE IN WORKING ORDER ALL WORK CALLED FOR HEREIN. 1. COLOR OF DEVICES AND PLATES SHALL MATCH WALL. THE DEVICES SHALL BE OF THE TYPES AND RATINGS LISTED, OR EQUALS BY ARROW-HART, GENERAL ELECTRIC OR PASS AND SEYMOUR. WEATHERPROOF GFCI RECEPTACLES SHALL BE INSTALLED WHERE SHOWN ON DRAWINGS OR AS REQUIRED BY CODE. DEVICES SHALL BE OF THE FOLLOWING SPECIFICATIONS, UNLESS OTHERWISE INDICATED SPECIFICALLY ON PLANS. A. A SWITCH HEIGHT 48" FROM FINISHED FLOOR TO CENTERLINE OF OUTLET. CONVENIENCE OUTLETS: a. SALES: 16" FROM FINISHED FLOOR TO BOTTOM OF OUTLET. b. NON-SALES: 16" FROM FINISHED FLOOR TO BOTTOM OF OUTLET TELEPHONE OUTLETS SHALL BE LOCATED AS NOTED ON DRAWINGS. PULL OR JUNCTION BOXES SHALL BE PROVIDED IN ALL RACEWAY SYSTEMS AT MAXIMUM OF 100 FOOT INTERVALS AND WHERE REQUIRED TO AVOID EXCESSIVE NUMBER OF BENDS, TO FACILITATE WIRE PULLING OR TO PROVIDE ACCESS TO RACEWAY SYSTEM. BOXES AND COVERS SHALL BE F. WIRING DEVICES, UNLESS OTHERWISE PROPERLY AUTHORIZED, SHALL BE SAME MANUFACTURERS GALVANIZED STEEL OF CODE GAUGE SIZE. TO THE EXTENT POSSIBLE, AVOID THE USE OF ONLY; NO ADDITIONAL MANUFACTURERS SHALL BE PERMITTED UNLESS SPECIFICALLY JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL AUTHORIZED BY TENANT OR TENANT'S REPRESENTATIVE. CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. JUNCTION AND PULL BOXES G. LOW VOLTAGE CONTROL DEVICES SHALL BE AS NOTED ON DRAWINGS OR AS REQUIRED. MUST BE LABELED WITH CIRCUIT NUMBER IDENTIFICATION AND SYSTEM TYPE ON COVER. 26 29 13 MOTOR CONTROLLERS RACEWAYS AND ENCLOSURES SHALL BE ADEQUATELY SUPPORTED FROM BUILDING STRUCTURE WITH APPROVED SUPPORT RODS AND/OR CLAMPS. A. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL MOTOR CONTROLS, INCLUDING STARTERS, SAFETY DEVICES AND REMOTE CONTROL STATIONS, UNLESS FURNISHED BY ALL CONDUIT SHALL BE RIGID HEAVYWALL GALVANIZED STEEL OR THIN WALL EMT WHERE EQUIPMENT MANUFACTURER IN PRE-WIRED ASSEMBLIES. PERMITTED BY CODE OR AS HEREINAFTER SPECIFIED. PVC SCHEDULE 80 CONDUIT MAY BE USED UNDER FLOOR SLAB. ROMEX, BX OR AC, ETC., ARE NOT PERMITTED. B. FURNISH AND INSTALL MANUAL MOTOR STARTERS WITH OVERLOAD RELAYS IN EACH LINE CONDUCTOR FOR ALL FRACTIONAL HORSEPOWER MOTORS NOT EQUIPPED WITH BUILT-IN MINIMUM SIZE OF CONDUIT SHALL BE 1/2" FOR INDIVIDUAL LIGHTING FIXTURE CONNECTIONS OR RUNNING OVERCURRENT PROTECTION, NOT REQUIRING AUTOMATIC CONTROLLERS. TO INDIVIDUAL LIGHT SWITCHES (IF ACCEPTABLE BY THE LANDLORD AND LOCAL CODE OFFICIALS) AND 3/4" FOR ALL OTHER LOCATIONS. IF HVAC CONTROL WIRING IS REQUIRED TO BE RUN IN C. MANUAL MOTOR STARTERS SHALL INCLUDE OVERLOAD RELAYS IN ALL LINE POLES SIZED TO TRIP CONDUIT, IT SHALL BE A MINIMUM OF 1/2", UNLESS NOTED OTHERWISE ON DRAWINGS. ALL SWITCH AT 125% OF MOTOR FULL LOAD RUNNING CURRENT, NEON PILOT LIGHTS, AND NEMA IN/UNDER FLOOR CONDUIT SHALL BE OF MINIMUM 1" SIZE. ENCLOSURES, AS MANUFACTURED BY GENERAL ELECTRIC, ALLEN BRADLEY, CUTLER HAMMER, SIEMENS, OR SQUARE-D. EMT THIN WALL CONDUIT MAY BE USED INSIDE HOLLOW PARTITIONS, AND ABOVE SUSPENDED CEILINGS AND EXPOSED ABOVE 8'-0" ABOVE FINISHED FLOOR OR ABOVE PANELBOARDS. EMT D. FURNISH AND INSTALL AUTOMATIC MOTOR STARTERS FOR ONE (1) HP OR LARGER SINGLE PHASE CONDUIT MAY NOT BE USED BURIED IN EARTH OR FILL, IN OR UNDER CONCRETE FLOOR OR IN AND THREE PHASE MOTORS OR MOTORIZED EQUIPMENT FURNISHED WITHOUT STARTERS, POURED CONCRETE CONSTRUCTION. REQUIRING AUTOMATIC STARTERS FOR CONTROL REGARDLESS OF HORSEPOWER RATING. ALL THREE PHASE STARTERS SHALL HAVE ANTI-SINGLE PHASING, UNDERVOLTAGE PROTECTION, AND PVC CONDUIT USED UNDER FLOOR SLABS SHALL HAVE RIGID GALVANIZED STEEL ELLS AND PHASE REVERSAL PROTECTION RELAYS EITHER INCLUDED IN STARTERS OR WIRED TO STARTER METALLIC CONDUIT ABOVE FLOOR SLAB. CONTROL CIRCUIT. V. A. A. D. E. 8 27 00 00 GENERAL REQUIREMENTS DUPLEX RECEPTACLES SHALL BE A MINIMUM OF 20 AMPERE RATING. ALL ELECTRICAL CONDUCTORS SHALL BE ENCLOSED IN CONTINUOUS GROUNDED RACEWAY SYSTEM EXCEPT AS OTHERWISE NOTED (I.E. LOW-VOLTAGE PLENUM-RATED WIRE). I. 7 C. INSTALL BOXES RIGIDLY FROM BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF FLOORS, CEILINGS, WALLS ETC. ALL OUTLET BOXES TO BE PROVIDED WITH CADDY "QUICK-MOUNT BOX SUPPORT" TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING/UNPLUGGING INTO THESE DEVICES. NO OTHER CIRCUITS ARE TO BE RUN IN SAME CONDUIT FEEDING ISOLATED GROUND RECEPTACLES. 6 UNLESS OTHERWISE NOTED ON DRAWINGS OR OTHERWISE REQUIRED BY THE NATIONAL ELECTRICAL CODE, ACCESSIBILITY CODES OR LOCAL CODES, OUTLET HEIGHTS SHALL BE AS FOLLOWS: 3. EXTERIOR BOXES SHALL BE CAST RUST-RESISTING METAL WITH GASKETED COVERS. H. 5 1. 2. ALL OUTLET BOXES SHALL BE GALVANIZED PRESSED STEEL OF THE STANDARD KNOCKOUT TYPE. NO ROUND OUTLET BOXES SHALL BE PERMITTED, EXCEPT AS SPECIFICALLY NOTED ON DRAWINGS. CONCEALED BOXES SHALL NOT BE LESS THAN 4" SQUARE AND 1-1/2" DEEP, WITH PLASTER RINGS. ALL KNOCKOUT BOXES, UPON WHICH LIGHTING FIXTURES ARE TO BE INSTALLED, SHALL BE EQUIPPED WITH 3/8" FIXTURE STUDS. G. H FURNISH AND INSTALL OUTLET BOXES FOR ALL DEVICES AS REQUIRED, (RECEPTACLES, LIGHTING FIXTURES, MOTORS, SYSTEMS EQUIPMENT CONNECTIONS, SPECIAL OUTLETS AND AS OTHERWISE REQUIRED). C. E. 4 LA PLAZA MALL 2 AT 1 8 9 10 11 12 13 14