plgc ii software
Transcription
plgc ii software
Gal-078 PLCG2Broch 4pg PLGC II 3/26/04 4:21 PM Page 1 天燃气气相色谱仪 PLGC II GAS CHROMATOGRAPH GAS COMPOSITION INCLUDING BTU/HEATING VALUE CALCULATION SPECIFIC GRAVITY CALCULATION Gal-078 PLCG2Broch 4pg 3/26/04 4:21 PM Page 2 PLGC II GAS CHROMATOGRAPH FOR PIPELINE AND PROCESS APPLICATIONS 2 1 3 The PLGC II is a compact and low cost gas chromatograph equipped with a universal thermal conductivity detector. The unit offers a wide range of applications where hydrocarbon gas or fixed gas analysis is required, such as in BTU measurement for the natural gas industry. 5 4 6 7 8 6 9 10 The PLGC II can be used in many measurement applications where an isothermal TCD scheme is suitable. It is a fully automated system designed to perform on-line, real time analysis. The Windows® based configuration software allows the user to view most recent or saved chromatograms as well as configure the analyzer. The PLGC II calculates the following for up to 8 streams: • Heating value • Compressibility • Specific gravity • Specific heat ratios • Wobbe index • Component concentrations Features: • 24 volt DC operation • No instrument air required • Division II electrical classification • Low helium consumption standard (Div I optional) • Thermistor TCD detector The excitation board provides power for the thermal conductivity detector. 3 The individual components are separated in the column by process of adsorption and diffusion. Up to two columns are supported. 4 The micro volume diaphram valve is actuated by carrier gas to perform the sample injection. 6 7 Customer connections for helium carrier gas, calibration gas and sample gas. Solenoids electromechanically switch the flow of gas to inject sample gas into the system. The computations, setup and communications for the PLGC II are performed by the Motherboard. 8 The LCD display is capable of displaying all information about the sample or status of the PLGC II. 9 Optional AC power adapter 10 Optional extended box to allow such options as: AC power and multiple streams. The detector is a temperature type TCD selected for high sensitivity at ambient temperatures and short response time. It consists of a heated filament contained in a stainless steel block. Gas flowing through the block loses heat to the block depending on the concentration and the thermal conductivity of the gas. The detector is in a temperature controlled enclosure to minimize the effect of ambient temperature changes. To further reduce temperature and flow effects, a reference filament is used in a wheatstone bridge configuration. TCD Detection 8 Milliamp Constant Current 4 Analyzer Detector Filament Support 525 A-A Mount T T 5 6 2 3 1 INTELLIGENT LCD Displays a choice of: • Heating valve/specific gravity • Component values • Chromatograms Output to Pre-amp 500 Ohm 500 Ohm FILAMENT SUPPORT 525 LU B 5 DETECTOR ED R 2 • Low maintenance R ED The TCD measures the concentration of the components of the sample gas based on changes in the thermal conductivity of the components. G R N 1 • Reliability • Temperature control • Output alarms • Status Gal-078 PLCG2Broch 4pg 3/26/04 4:21 PM Page 3 Sample SAMPLE INJECTION VALVE The chromatograph is composed of a 10-port micro volume diaphragm valve and generally 2 columns (some applications may only require one). The DV22 performs the injection and the backflush. It is specifically designed for heavy-duty applications and is rated at 1,000,000 injections before requiring service. In two column systems, column 1 passes all components except C6+, trapping C6+ for a quick backflush out. Column 2 separates the remaining components. Total analysis time is approximately 15 minutes and is run iso-thermally at 40°C (optional 5 min cycle time is also available). The temperature of the chromatography enclosure is controlled to minimize retention time shifts due to ambient temperature changes. Vent 1 10 PLGC 2 9 II Sample Handling Equipment 3 8 Carrier 4 col 1 7 6 5 col 2 Detector Valve On Sample Vent 10 1 2 9 3 8 4 Carrier col 1 7 6 Detector PLGC II SOFTWARE 5 col 2 Valve Off The PLGC II software has been designed to receive, interpret, and plot data from the PLGC II gas chromatograph. Peaks in the resulting chromatogram identify the compounds by retention time and the concentration by the area of the peak. Various parameters, including heating value, specific gravity, and compressibility factor, can be displayed with the software. The Graphical User Interface (GUI) for the software is a user friendly Windows® based system. Computer Requirements: Operating System: DIMAC Gas Chromatogram ® An IBM compatible PC with “Windows 98, NT or ME” operating system will be required. Memory: The PC must have a minimum of 64 MB of RAM. Disk Drives: The PLGC II configuration program is provided on CD Rom, and requires at least 20MB on the disk drive. Extra space will be required to save data. Serial Port: To run the PLGC II configuration program a supplied serial cable is required to connect the personal computer to the PLGC II. Most computers will have multiple COM ports to select from. The COM port selected cannot be shared with any other device. Gal-078 PLCG2Broch 4pg 3/29/04 9:47 AM Page 4 SPECIFICATIONS DIMENSIONS Range: 0-1000 ppm to 100% for individual components PLGC II - DIVISION II (Optional Cabinet - 28”x28”x15”) Components: 16 maximum Streams: 8 plus calibration 25” Response: 15 minutes to C6+ (4 minutes optional), 2 minutes nominal for single components depending on background composition 9” 16” 12” 25” 17” Linearity: 1% for individual components Repeatability: +/- 1 BTU or 0.1% Temperature ambient: 10 to 40° C Humidity: 0-95% non-condensing PLGC II - DIVISION I (Optional Cabinet - 30”x36”x15”) 10” 27” Electrical: 24 volts DC @ maximum 50 watts (nominal 24 watts) Certified Class 1 Div 2 Grp B, C, D(CUL) Temp code T3 EEX nA II B T3 (ATEX) Inputs: 6 dry contacts Display: 240 x 64 backlit LCD 33” Relays: Four user selectable for alarm or fault (SPDT, 5 amps, 120 VAC) Analog: Four isolated 4-20 mA (user selectable) Serial: Two RS-232, One RS-485 modbus Data logging: Hourly 32 Daily 32 Weekly 32 Monthly 32 Yearly 32 By Analysis 32 items items items items items items 2 years 10 years 10 years 20 years 20 years 9400 analysis Input A/D: Three channels 24 bit sigma delta Real time clock: Time and date stamp, 1 ms resolution Sampling rate: 60 HZ Chromatograph valve: Maximum eight Columns: One to four 1/16” stainless steel (application dependent) Dimensions: 17” H X 16” W X 9” D Weight: 35 pounds Utilities: UHP helium @ 10 cc/min @ 60 PSI Sample: 10 to100 PSI clean, Dry gas @ 95 cc/min MODIFIED SPECIFICATIONS FOR THE PLGC II EXPLOSION PROOF Electrical: 120/240 VAC @ 50 watts Class 1 Div 1 Grp C,D Temp Code T3 Weight: 50 pounds Dimensions: 29” H X 13” W X 9” D Cabinet may vary in size according to the number of streams and valves. ISO 9001: 2000 Registered QMS QCB # 00-1403 www.gasanalyzer.cn