HiMAP
Transcription
HiMAP
HYUNDAI DIGITAL PROTECTION & MEASURING DEVICE HiMAP&HiCAM-II Hyundai Intelligent Measuring & Protection Device HiMAP Hyundai Intelligent Communication & Measuring Device HiCAM-II HYUNDAI DIGITAL PROTECTION & MEASURING DEVICE HiMAP is a multifunctional digital protection relay that has a protection function to protect incoming and feeder lines, the motor and the transformer. It also has various kinds of measuring functions to check synchronization and a communication function for the Power Management System (HIPMS) to supervise operating conditions. HiCAM-II has integrated as many as 15 analog meters in one body. The measuring accuracy is below ±0.2-1.0% at rating. For power monitoring system connection, HiCAM has RS485 communication port, communication control device (HICM series) and support modbus protocol. Remote CB On/Off control is possible by the command from power monitoring system. Protection Relay Function Measuring Function Event Record Function Communication Function Circuit Breaker Remote Control Function Fault Wave Record Function HiMAP Hyundai Intelligent Measuring & Protection Device Characteristics M-2 Display M-4 Power Management System HIPMS-Plus M-6 Setting Range M-8 Connection Diagram M-9 Terminal Block Pin Specification M-11 Characteristic Curve M-12 Order Form M-14 View & Dimension M-15 HiMAP Hyundai Intelligent Measuring & Protection Device Characteristics ▶ Excellent operating characteristics using a 32 bit microprocessor. ▶ Easy to operate using an interactive menu system. ▶ Easy to connect monitoring system & local computer using four communication channels. ▶ Increased reliability using a self-diagnostic function. ▶ Designed for operator’s convenience. Easy Installation and Maintenance HiMAP is designed with a removable case so that the external electric lines can be connected to the inner part for easy installation and maintenance. Self-diagnosis Function HiMAP has a self-diagnosis function set to observe any system failures, send an alarm signal, and display it on the VFD window. Use of a Digital Filter HiMAP uses a digital filter, which prevents any harmonic effects from the high frequency on the power line. Circuit Breaker Remote Control Function HiMAP remotely controls circuit breakers by means of the command from SCADA Systems and controls the load of power in the computer through RS-485 communication port. If there is interfacing with another company’s monitoring system, it is easy to connect both systems because our communication control device provides various interface ports and protocols. Harmonic Analysis Function ▶ Harmonic contents (1st-18th) for three phase current can be measured. (THD, TDD) ▶ Harmonic contents for three phase fault wave can be analyzed using HiMAP manager program. Fault / Event Recording Function HiMAP saves fault events up to 100. Each event data has a fault phase, pick up ratio, operating time and fault date. Also, for the latest fault, HiMAP saves a fault wave which is 300 cycles with the resolution 36 sampling / cycle. This can be transfer to monitoring system by communication port. Vector Diagram Harmonic Analysis M-2 HiMAP Protection Relay Function Model Protection Object HiMAP–FI Incoming Feeder HiMAP–M Motor HiMAP-T Transformer HiMAP-SC Syncro-Check Relay Function •OCR(50/51) •SGR(67G) •UVR(27) •OCGR(50G/51G) •OVR(59) •PSR(47P/47N) •DGR(67G) •DOCR(67) •OVGR(64) •DOCGR(67N) •Trip coil supervision(94) (Option) •OCR(50) •NCHR(66) •SGR(67G) •51LR •UCR(37) •DFR(87M) •THR(49) •NSR(46) •OCGR(50G/51G) •DGR(67G) •Closing/Trip coil supervision(94)(Option) •OCR(50/51P)✽ •OCR(50/51S)✽ •DGR(67G) •Closing/Trip coil supervision(94)(Option) •DFR(87T) •OCGR(50G/51G) •SGR(67G) •SCR(25) •UVR(27) ✽ HiMAP-T Type has 2 OCRs. P means primary and S means secondary. Measuring Function HiMAP has a measuring function as shown in the below table. It displays the value of each measurement on the VFD window by operating a menu key and then transfers and displays the data on the HIMIX window, which has an outside digital indicator connected by a communication cable. Various kinds of measuring values are converted to a primary value by input of a CT/PT ratio and then displayed on the VFD window. Measuring Display Accuracy (%) 0-999999V ±0.2 Current(Ir, Is, It, Io, Ips, Ins, Iavg, ITHD, ITDD) 0-999999A ±0.2 Real Power 0-99999999 kW ±0.2 Reactive Power 0-99999999 kvar ±0.5 Accumulated Real Energy 0-99999999 kWh ±1.0 Accumulated Reactive Energy 0-99999999 kvarh ±1.0 Power Factor -1.0-1.0 PF ±0.5 Power Voltage(Vr, Vs, Vt, Vo, Vps, Vns, Vavg, Vomax) Frequency 45-65Hz ±0.01Hz ※ CT/PT ratio will be set by using relay control keys and then displayed via VFD window. The values will be saved at flash memory even though the power line will be off. Communication Function HiMAP has four communication ports. RS-485 ports transfer all information related to relay operation status, measuring information, and operation status of circuit breakers. This information is then perceived by HiMAP and sent to communication control device at the speed of 62.5 K bps, using RS-485 HDLC frame protocol and MODBUS-RTU protocol. The communication control device connects a master PC to the Power Management System (HIPMS) at the speed of 10M bps by Ethernet, TCP/IP. Please refer to the HIPMS manual for details on the monitoring function. HIMIX communication port transfers kinds of measuring values optional to HIMIX at the speed of 9600 bps. The external port of HiMAP transfers the fault record from a site to the PC for analysis, changes the relay element value to a correct one, and is an RS-232C communication port to monitor the status of all kinds of protection relay. Interface with SCADA Communication Control Device Type of Communication Protocol HICM-PC(II) Ethernet Modbus / TCP M-3 HiMAP Hyundai Intelligent Measuring & Protection Device Display Front View Display Window(VFD) Exterior Case Internal Case System Status Indicator CB Status CB Control (Normal Operation, System Fail, Fault) Display Key Input Key Select Switch & Led RS232 Port Set M-4 Movement Key ACK HiMAP Specification Item Rating Accuracy Temperature Insulation Resistance Voltage Withstand Overland Withstand Specification Current 1A or 5A, Burden: Below 0.1VA/Phase Voltage 110V or 190V, Burden: Below 0.3VA/Phase Frequency 50Hz or 60Hz Measuring ±0.2% Protection Relaying ±2% Operation Guarantee -10℃ - 55℃ Restoration Guarantee -25℃ - 70℃ Circuits-Ground 10 MΩ Between Circuits 5 MΩ Between Contacts 5 MΩ Power Frequency AC 60Hz 2000V/1 Min Lightning Impulse 1.2/50㎲ 5 kV Current Circuit Rating Current×3: 3 hours / Rating Current × 20: 2sec Voltage Circuit Rating Voltage × 3: 3 hours Control Power Rating Voltage × 1.3: 3 hours Control Power Interruption Maximum 300 ms Control Power AC/DC 95V - 250V 50/60Hz, DC 48V Standards IEC 60255 / KEMC 1120 / IEC 61000-4 Communication Type RS-485 Multi Drop Protocol HD-BUS / DNP 3.0 / MODBUS Size 202.5(W) × 156(H) × 251(D) Weight 4.3kg I / O Point Item Input Point Remark AI Voltage 4 Default✽ AI Current 4 Default✽ DI 5 Default DO 7 Default(R1-R7) (21-34) Output 31, 32(R6): Remote CB On 33, 34(R7): Remote CB Off ✽ HiMAP-87M(Self-balancing Type) : Current(7CH), Voltage(1CH) HiMAP-87M(Differential Type) : Current(7CH), Voltage(0CH) HiMAP-T : Current(7CH), Voltage(1CH) M-5 HiMAP Hyundai Intelligent Measuring & Protection Device Power Management System HIPMS-Plus System Configuration Remote HIPMS-Plus Station To Wide and Local Area Networks Enterprise Management Network Web Client (Web Browser) Router Mobile Phone (SMS) GPS Web Server Maintenance & Operating Multi Server Maintenance & Operating Multi Server Internet Redundant Ethernet Network 10/100Mbps(Fiber Optic) FEP HICM860S(P) HICM860S(S) HICM860S(P) HICM860S(S) HICM860S(P) HICM860S(S) Notebook PC HiMAP-BC RTU(HRC-NET) HiCAM-II Display Configuration M-6 System Configuration System Detail(1) System Detail(2) HiMAP Detail RTU Detail Network Status HiMAP Alarm Printer External System Network Report Printer Color Hard Copler Gateway HICM860S(P) HICM860S(S) HiMAP-F HICM860S(P) HICM860S(S) HiMAP Trend Report Setting Report Alarm Fault Analysis Remote Setting HiMIX M-7 HiMAP Hyundai Intelligent Measuring & Protection Device Setting Range FI Type Mode OCR (50/51) OCGR (50G/51G) UVR (27) POR 47P NSOVR 47N OVR (59) OVGR Current (67GD) SGR (67GS) Below 0.05sec 0.05-10.0sec (0.01sec Step) Mode Instant Definite Current (67) DOCGR (67N) Inverse, Very Inverse, Extremely Inverse (0.02-1.0) × In (Time Delay) (0.1A Step) (0.1-12) × In (0.1A Step) Below 0.05sec 0.05-10.0sec (0.01sec Step) 0.05-10.0 Tap (Time Delay) (0.01 Step) Mode - Definite - Voltage - (0.2-1.0) × Vn (0.1V Step) - Time - 0.1-10.0sec (0.1sec Step) - Mode - Definite - Voltage - (0.5-1.0) × Vn (0.1V Step) - Time - 0.1-10.0sec (0.1sec Step) - Mode - Definite - Voltage - (0.02-0.5) × Vn (0.1V Step) - Time - 0.1-10.0sec (0.1sec Step) - Mode - Definite Inverse Voltage - Time - 0.1-10.0sec (0.1sec Step) 0.05-10.0 Tap (Time Delay) (0.01 Step) Mode Instant - Inverse (1.1-1.45) × Vn (0.1V Step) Voltage (0.11-0.5) × Vn (0.1V Step) Time Below 0.05sec Mode Definite Current (0.04-0.4) × In (0.1A Step) Voltage (0.1-0.2) × Vn (0.1V Step) Time 0.1-10.0sec (0.1sec Step) Angle 10°- 45°(1°Step) Mode Definite Current 1-10 mA (0.1 mA Step) Voltage (0.1-0.2) × Vn (0.1V Step) Time 0.1-10.0sec (0.1sec Step) Angle 45°-75°(1°Step) Instant - 0.05-10.0 Tap (Time Delay) (0.01 Step) Definite Inverse, Very Inverse, Extremely Inverse Current - (0.20-2.40) × In (0.01A Step) Voltage - (0.03-1.45) × Vn (0.1V Step) Time - Angle - Mode Instant Current - Voltage - Time - Angle - ※ - In: Rating Current, Vn: Rating Voltage - Example HiMAP Setting; In: 5A, OCR: (1-18)×In → 5-90A M-8 0.05-10.0 Tap (Time Delay) (0.01 Step) Time Mode DOCR (0.2-2.4) × In (Time Delay) (0.1A Step) (1-18) × In (0.1A Step) Time (64) DGR Inverse, Very Inverse, Extremely Inverse Definite Instant 0.05-10.00sec (0.01sec Step) 0.05-10.00 Tap (Time Delay) (0.01 Step) Ref. Angle: 0°-359°(1°Step), Op. Angle: ±30° -90°(1°Step) Definite Inverse, Very Inverse, Extremely Inverse (0.05-10.00) × In (0.01A Step) (0.1-0.5) × Vn (0.1V Step) 0.05-10.00sec (0.01sec Step) 0.05-10.0 Tap (Time Delay) (0.01 Step) Ref. Angle: 0°-359°(1°Step), Op. Angle: ±10° -170°(1°Step) HiMAP Connection Diagram HiMAP-FI(3CT, 3PT) R S T R1 PT / GPT 21 9 22 DISPLAY 10 11 R2 23 12 13 24 14 R3 Relay CPU 15 16 26 R4 Output 27 28 GPT 3rd CB Programmable 25 R5 29 1 30 2 R6 31 3 50 4 5 CT 51 6 7 32 R7 33 34 50G 8 Local/ Remote CB On Local/ Remote CB Off 35 NA 51G 36 27 37 CCS 38 47P Option 39 R S T DC 24 V 2 50 52a CT 52b 51 42 64 43 67G NA 45 46 6 Remote 52 67 67N 7 ZCT 41 44 4 5 40 59 1 3 TCS 47N 8 DI1 DI2 53 Vn Power 60 61 63 RS485 (Scada) 64 KEYBOARD 65 Vp Vn Control 48 62 54 59 When using ZCT (SGR) 47 Vp 66 67 RS485 (HIMIX) 68 Option P N FG M-9 HiMAP Hyundai Intelligent Measuring & Protection Device Connection Diagram HiMAP-FI(2CT, 2PT) R S T R1 PT × 2 21 9 22 DISPLAY 10 11 R2 23 12 13 24 14 R3 Relay CPU 15 26 R4 16 Programmable 25 Output 27 28 CB R5 29 1 30 2 R6 31 3 50 4 5 CT 51 6 7 32 R7 33 34 50G 8 Local/ Remote CB On Local/ Remote CB Off 35 ZCT NA 51G 36 27 37 CCS 38 47P Option 39 R S T DC 24 V TCS 47N 40 59 50 52a 41 42 64 43 44 52b 51 67G NA 45 46 Remote 47 52 Vp DI1 DI2 Vn 53 P N FG M - 10 61 63 RS485 (Scada) 64 KEYBOARD 65 Vp Vn Power 60 62 54 59 Control 48 66 67 RS485 (HIMIX) 68 Option HiMAP Terminal Block Pin Specification HiMAP-FI Type Control Power Terminal P N (+) (-) FG Communication Terminal 60 61 62 63 64 65 Vp Vn Vp Vn HIMIX Communication Terminal 66 67 68 Digital Output 41 42 43 44 45 46 47 48 Vp Vn N.A. N.A. Digital Input 50 51 52 53 54 55 56 57 58 59 52a 52b Remote D/I 1 D/I 2 N.A. Common(+24V) R1 R2 R3 R4 R5 R6(CB On) R7(CB Off) N.A. CCS TCS 21 23 25 27 29 31 33 35 37 39 Analog Input 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 Ia Ib Ic Io Va Vb Vc Vo N.A. N.A. Terminal No. Description Application 50 51 52 53 54 21-22 23-24 25-26 27-28 29-30 31-32 33-34 35-36 37-38 39-40 CB On Status 52a CB Off Status 52b Remote Input General DI General DI R1 R2 R3 R4 R5 R6(CB On) R7(CB Off) N.A. TCS TCS Fixed Fixed Fixed Variable Variable 2 4 6 8 10 12 14 16 18 20 Programmable Relay Output Fixed Fixed N.A. Fixed Fixed M - 11 HiMAP Hyundai Intelligent Measuring & Protection Device Characteristic Curve OCR & OCGR Inverse | OP LEVEL 0.05-10.0 0.01 Very Inverse | OP LEVEL 0.05-10.0 0.01 DOCR Extremely Inverse | OP LEVEL 0.05-10.0 0.01 M - 12 DOCR Op. Current Ia Ib Ic Ref. Volt Vbc Vca Vab HiMAP OVR Inverse | OP LEVEL 0.05-10.0 OVGR Very Inverse | OP LEVEL 0.05-10.0 0.01 0.01 DGR / SGR / DOCGR DGR SGR DOCGR M - 13 HiMAP Hyundai Intelligent Measuring & Protection Device Order Form A. Type Selection of HiMAP Please check mark(⋏) into the type required. HiMAP – ❶ – ❷ ❸ – ❹ (Option) ❶ ❷ Relay Type Feeder/Incoming FI Motor M 87M Big Motor Transformer T SY Synchro check ❹ (option) 4) ❸ Ground Fault Type C OCGR D DGR / DOCGR S SGR Communication RS-485 HDLC C No System Interface X M MODBUS-RTU T X TCS Function Required Not Apply ※ Type of 87M (Protection for big motor): ( ) self-balancing type / ( ) differential type B. System Specification Required Please check mark(⋏) into a parenthesis. 1) Measuring Current (CT) Inputs for OCR: ( ) 5A / ( ) 1A 2) Measuring Zero Phase Current (ZCT) Inputs for GFR: ( ) 5A / ( ) 1A / ( ) 1.5 mA 3) Frequency 3): ( ) 50Hz / ( ) 60Hz 4) Measuring Voltage (line to ground) inputs: ( ) 110V / ( ) 190V / Others ( V) C. Ground Fault Function Selection Table 1 (FI) DGR(67G) / DOCGR(67N) Item OCR(50/51) OCGR(50/51G) C D S ● ● ● ● Item MPR OCGR(50/51G) C D S ● ● ● ● Item 87M MPR OCGR(50/51G) C D S ● ● ● ● ● ● ● SGR(67G) OVR(59) UVR(27) OVGR(64) PSR(47P/47N) ● ● ● ● ● ● ● ● ● ● ● ● ● ● Table 2 (M) DGR(67G) / DOCGR(67N) SGR(67G) ● ● Table 3 (87M) DGR(67G) / DOCGR(67N) SGR(67G) ● ● Table 4 (T) Item DFR C D S ● ● ● OCR P(50/51P) 1) OCR S(50/51S) 2) OCGR(50/51G) DGR(67G) / DOCGR(67N) ● ● ● ● ● ● ● ● ※ 1) OCR P is transformer primary OCR 2) OCR S is transformer secondary OCR 3) The control voltage of HiMAP is only allow AC / DC 95 - 250V, 50 / 60Hz as a free voltage 4) TCS(Trip Coil Supervision): Circuit breaker coil disconnection check. (option) Note Ground fault function shell be selected in accordance with the system ground method. - OCGR (50G/51G): Effective ground system - DGR (67G): Resister ground system - SGR (67G): Floated ground system M - 14 SGR(67G) ● HiMAP View & Dimension 139 Weight 4.3Kg 186 Panel Cut-out Dimension 156 Top View 33 218 251 206 Side View 138 Front View 185 Rear View M - 15 HiCAM-II Hyundai Intelligent Communication & Measuring Device Characteristics C-2 Display C-2 Connection Diagram C-4 Terminal Block Pin Specification C-5 View & Dimension C-6 HiCAM-II Hyundai Intelligent Communication & Measuring Device Characteristics Accuracy ▶ ±0.2~1.0% at rating Compact Size and Display ▶ Various indicator and measuring display ▶ Size : 202.5 (W) × 156 (H) × 189 (D) Voltage / Current Input Power Management System Connection ▶ CT : 0.1~10 A ▶ PT : 10~380 V ▶ RS485 HD-Bus ▶ Modbus protocol by communication control device Various Measuring (HICM Series) ▶ 15 measuring points Display Front View Display Window Communication Address Current, Active Power % Display D/I Status LED Select Key D/O Status LED Navigation Key CB Control Switch/LED Remote Key C- 2 HiCAM-II I / O Point Point Item Input Output AI Voltage AI Current Remark 4 Default 4 Default DI 12 Default(41~55) DO 5 Default(31~40) 37, 38(D04) : Remote CB On 39, 40(D05) : Remote CB Off 31~36(D01~D03) use current demand output. Specification Specification Item Rating Accuracy Temperature Insulation Resistance Voltage Withstand Overland Withstand Current 1 A or 5 A(0.1 A~10 A), Burden : Below 0.1 VA / Phase Voltage 110 V or 190 V(10 V~380 V), Burden : Below 0.3 VA / Phase Frequency 50 Hz or 60 Hz Measuring ±0.2 % Operation Guarantee -10 ℃ ~ 55 ℃ Restoration Guarantee -25 ℃ ~ 70 ℃ Circuit-Ground 10 ㏁ Between Circuits 5㏁ Between Contacts 5㏁ Power Frequency AC 60 Hz 2,000V/1 Min Lightning Impulse 1.2/50 ㎲ 5 kV Current Circuit Rating Current×3 : 3 hours / Rating Current×20 : 1 sec Voltage Circuit Rating Voltage×3 : 3 hours Control Power Rating Voltage×1.3 : 3 hours Control Power AC 85 ~ 264 V (50 / 60 Hz), DC 90 ~ 120 V Power Consumption 18 VA, AC 220 V Communication Type RS–485 / Multi Drop Protocol HD-BUS / Modbus Standards KEMC1110, IEC1036 Size 202.5 (W)×156 (H)×189 (D) Weight 1.5 Kg Measuring Accuracy Remark Voltage 0~999999 V ±0.2% Line to Line Voltage Current 0~999999 A ±0.2% Phase Current Real Power 0~99999999 kW ±0.2% Reactive Power 0~99999999 kvar ±0.5% Apparent Power 0~99999999 kVA ±1.0% Accumulated Real Energy 0~99999999 kWh ±1.0% Accumulated Reactive Energy 0~99999999 kvarh ±1.0% Power Factor -1.0~1.0 PF ±0.5% Frequency 45~65 Hz ±0.01 Hz Reverse Real Power 0~999999 kW ±0.5% (-) Sign Reverse 0~999999 kWh ±1.0% (-) Sign Measuring Display C- 3 HiCAM-II Hyundai Intelligent Communication & Measuring Device Connection Diagram 3P 4W 3PT_3CT RS T N 3P 3W 2PT_2CT 45/50/55 41 PT/GPT 42 43 44 46 47 48 49 51 52 53 RS T 54 45/50/55 41 PT 9 10 12 Vp Vn 15 16 AI 1 2 3 4 5 6 7 8 48 49 51 52 53 54 DI Vp Vn 66 67 15 16 L N FG AD/DC R5 39 R4 38 37 R3 36 R2 35 34 33 95~250V 50/60Hz R1 32 1 2 3 4 5 6 7 8 CT COMM. L N FG DO AD/DC R5 40 31 Remote CB On : 37, 38 Terminal Remote CB Off : 39, 40 Terminal 66 67 68 69 70 AI COMM. DO 40 39 R4 38 37 R3 36 R2 35 34 33 R1 32 95~250V 50/60Hz 31 Remote CB On : 37, 38 Terminal Remote CB Off : 39, 40 Terminal 3P 3W 3PT_3CT 3P 3W 2PT_3CT 45/50/55 41 42 43 44 46 47 48 49 51 52 53 RS T 54 45/50/55 41 PT 9 10 11 42 43 44 46 47 48 49 51 52 53 54 9 10 11 12 12 DI 13 Vp Vn 15 16 14 AI 15 16 L N FG AD/DC R5 40 39 R4 38 37 R3 36 35 R2 34 33 R1 32 Remote CB On : 37, 38 Terminal Remote CB Off : 39, 40 Terminal 31 95~250V 50/60Hz CT 66 67 68 69 70 AI COMM. DO Vp Vn 66 67 68 69 70 1 2 3 4 5 6 7 8 DI 13 14 C- 4 47 14 68 69 70 GPT CT 46 13 14 PT 44 12 DI 13 RS T 43 11 11 CT 42 9 10 1 2 3 4 5 6 7 8 COMM. L N FG DO AD/DC R5 40 39 R4 38 37 R3 36 35 R2 34 33 R1 32 Remote CB On : 37, 38 Terminal Remote CB Off : 39, 40 Terminal 31 95~250V 50/60Hz HiCAM-II Terminal Block Pin Specification Control Power Terminal L N FG (+) (-) FG Terminal 56 57 58 59 60 61 62 63 64 65 N.A. Communication Terminal 66 67 68 69 70 Vp Vn Vp Vn N.A. Digital Input 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 52a 52b Remote DI 1 Common(+24V) DI 2 DI 3 DI 4 DI 5 Common(+24V) DI 6 DI 7 DI 8 DI 9 Common(+24V) Digital Output 31 32 33 34 35 36 37 38 39 40 1 3 5 7 9 11 13 15 17 19 R1(+) R1(-) R2(+) R2(-) R3(+) R3(-) R4(CB On) R4(CB On) R5(CB Off) R5(CB Off) Terminal No. Description 31~32 R1 33~34 R2 35~36 R3 37~38 R4(Remote On) Fixed 39~40 R5(Remote Off) Fixed 41 CB On Status 52a 42 CB Off Status 52b 43 Remote Input 44 General DI Variable 45 Common HiCAM Self Power +24V 46 General DI Analog Input 47 General DI Ia Ib Ic Io Vab Vbc Vca Vo N.A. N.A. 48 General DI 49 General DI 2 4 6 8 10 12 14 16 18 20 50 Common 51 General DI 52 General DI 53 General DI 54 General DI 55 Common Application Variable Fixed Variable HiCAM Self Power +24V Variable HiCAM Self Power +24V C- 5 HiCAM-II Hyundai Intelligent Communication & Measuring Device View & Dimension Weight 1.5Kg 139 186 Panel Cut-out Dimension Top View 189 33 141 156 206 Side View Front View 138 185 Rear View C- 6 15 HHIS-WC-SE-B11-04, 2009.12 Designed by MERMONT Head Office 1, Jeonha-dong, Dong-gu, Ulsan, Korea Tel: 82-52-202-8101~8 Fax: 82-52-202-8100 Seoul (Sales & Marketing) 140-2, Gye-dong, Jongno-gu, Seoul, Korea Tel: 82-2-746-7579, 7523 Fax: 82-2-746-7648 Orlando 3452 Lake Lynda Drive, Suite 170, Orlando, Florida 32817, U.S.A. Tel: 1-407-249-7350 Fax: 1-407-275-4940 New Jersey 300 Sylvan Avenue, Englewood Cliffs, NJ 07632, U.S.A. Tel: 1-201-816-0286 Fax: 1-201-816-4083 London 2nd Floor, The Triangle, 5-17 Hammersmith Grove, London, W6 0LG, UK Tel: 44-20-8741-0501 Fax: 44-20-8741-5620 Tokyo 8th Fl., Yurakucho Denki Bldg.1-7-1, Yuraku-cho, Chiyoda-gu, Tokyo, 100-0006, Japan Tel: 81-3-3212-2076, 3215-7159 Fax: 81-3-3211-2093 Osaka I-Room 5th Fl. Nagahori-Plaza Bldg. 2-4-8, Minami Senba, Chuo-Ku, Osaka, 542-0081, Japan Tel: 81-6-6261-5766, 5767 Fax: 81-6-6261-5818 Dubai Level 2, Unit 205, Emaar Square-Bldg.4 Sheikh Zayed Road, P.O.Box 252458, Dubai, U.A.E. Tel: 971-4-425-7995 Fax: 971-4-425-7996 Sofia 1271, Sofia 41, Rojen Blvd., Bulgaria Tel: 359-2-803-3200 Fax: 359-2-803-3203 Yangzhong No. 9 Xiandai Road, Xinba Scientific and Technologic Zone, Yangzhong, Jiangsu, P.R.C. Zip: 212212, China Tel: 86-511-8842-0666, 0212 Fax: 86-511-8842-0668, 0231
Similar documents
C7 VIMAC 3000
Reverse Active Power Reactive Power Apparent Power Active Electric Energy Reactive Electric Energy Apparent Electric Energy Reverse Active Power Power Factor Frequency Voltage Harmonics Current Har...
More information