Ormazabal
Transcription
Ormazabal
Focus on Medium Voltage Value for the customer Solutions 2009 Ormazabal 2 Who We Are As one of the leading manufacturers of Medium Voltage switchgear worldwide, we provide our customers with solutions for electrical distribution networks that are based on high added-value products and services. We can rely on our personnel, their knowledge and commitment, to establish win-win relationships with our customers and suppliers. Our management is based on our values: Flexibility, Leadership, Innovation, Pragmatism and Support. Since its beginnings in 1967, Ormazabal has been a driving force for innovation in the electrical distribution sector, working closely with utilities around the world. ‘Flexibility’ ‘Leadership’ ‘Innovation’ ‘Pragmatism’ ‘Assistant’ 2009 Ormazabal 3 Distribution Power Network 2009 Ormazabal 4 Customer Orientated Based on: Generating value Meeting their present and future needs Promoting excellence in service Building long-term, win-win relationships Customer satisfaction is the result of close collaboration. This allows us to offer the best solutions, combining knowledge and experience, as well as products and service. 2009 Ormazabal 5 Focus on Medium Voltage Because …. 2009 Medium Voltage is our business We are committed to meeting our customers’ needs We enjoy close, direct relationships with our customers Our highly qualified team is closely involved in each project We offer extensive experience and breadth of knowledge Our enterprising spirit leads us to innovative technological breakthroughs in electrical equipment. Ormazabal 6 We Offer Solutions We are accessible to our customers, and offer them the best solutions to meet their needs. Our commitment to... The safety of people and property Quality The environment And our experience based on ... Customer orientated approach Developing customised products and services Intensive use of technology …. define us as the natural partner for our customers. 2009 Ormazabal 7 What We Offer Solutions Products Services Solutions: By correctly identifying the customers' needs, we can design the best solution, combining the most suitable products and services in order to ensure their complete satisfaction. 2009 Ormazabal 8 What We Offer Solutions Products Services Products: At Ormazabal we offer a complete range of products for Medium Voltage Electrical Distribution. 2009 Ormazabal 9 What We Offer Solutions Products Services Services: From the beginning we have been developing and providing customised services that complement our products, together with an extensive experience in their application. 2009 Ormazabal 10 Sustained Growth Foundation Lemona, Vizcaya, 1967 We are defined by our constant growth, own technology Spain and creation of value for our customers. Headquarters Our international expansion is principally based on: Zamudio, Vizcaya Spain Technological development No. of employees in 2008 1623 people Knowledge management Turnover in 2008 550 Mill. € Offering local solutions Internationalisation Ormazabal operates and sells in Establishing long-term relationships more than 30 countries Installed Product Units 600 · Distribution cubicles 500 of up to 36 kV > 1,000,000 f.u. 400 · Transformer Substations > 100,000 u. 300 Growth 200 · Low Voltage Boards > 130,000 u. 100 · Protection, Control > 78,000 u. 0 1994 2009 · Transformers > 124,000 u. 1995 1996 1997 1998 1999 2000 2001 2002 2003 2005 2006 2007 2008 Ormazabal · Automation > 3.000 u. 11 Ormazabal's size in 2008 Global Medium Voltage Market ABB ABB 9% Other manuf. Siemens Areva C. Hammer Schneider Schneider Siemens Areva Cutler - Hammer 4% Ormazabal is the world's second manufacturer of MV Secondary Distribution + Compact Substations 2009 Ormazabal is among the top six MV manufacturers Ormazabal 12 Innovation and Development Since its foundation, Ormazabal has made a commitment to Innovation by creating a New Products Department (now R&D) to develop the most competitive solutions, thus anticipating our customers' needs. This drive to innovate has resulted in many patents, again demonstrating Ormazabal’s technological independence. Innovations in solutions, products and services require many different technologies to be incorporated into our designs and processes. The opening of our High Power Laboratory (HPL), with a capacity of up to 2500 MVA, has reinforced our ‘Technological Development’. As our innovation process evolves, we are giving greater importance to research projects, increasing our ability to offer better solutions to our customers. 2009 Ormazabal 13 Ormazabal Corporate Technology Research and Technology Centre The purpose of the Research and Technology Centre is to identify, acquire and spread strategic product or process technologies within Ormazabal. 2009 Ormazabal 14 Ormazabal Corporate Technology HPL (High Power Laboratory) HPL is the only High Power Laboratory (2500 MVA) in Spain and the most modern in the world (start-up in year 2008). 2009 Ormazabal 15 International Development Ormazabal's global presence demonstrates the ability of our personnel and organisation to succeed in our ongoing internationalisation process. This process has increased our presence in a large number of countries and facilitates our customer-orientated approach. In addition, this is reinforced through the establishment of in-country subsidiaries and collaboration with our partners. 2009 Ormazabal 16 Global Technology - Local Solutions Secondary D. Transformer Subs. Primary D. Distrib. Transf. Protec. & Automat. LV Boards Ormazabal's Locations 2009 Applications Commercial References Grupo Ormazabal's Diversification Ormazabal Product Tree 17 Solutions,Products Products Solutions, and Services for and Services for ElectricalDistribution Distribution Electrical Networks Networks 2009 Ormazabal 18 Global Technology - Local Solutions Primary D. Air - Insulation CPA-AMC Transf. Subst. Prefabricated miniBLOK miniSUB GIS CPG.0 MB CPG.1 CTR ormaSET VCB NVL ormaBAT CTC Secondary D. SF6 - Insulation RMU CGMCOSMOS CTO CGM.3 Enclosure Preforma-PF GA Modular PF CGMCOSMOS PFS CGM.3 Switching Subst. Air - Insulation PFU PF-15 EA Metallic Enc. LV Boards CDB CBTO Components KL / T / DES Distrib. Transf. ormaLINK P&A Up to 2500 Applications Protection 2009 Ormazabal's Size Wind Farms Solar Inst. Automation Ormazabal's Locations Up to 160 Commercial References Ormazabal Grupo Ormazabal's Diversification 19 Primary Distribution Switchgear CPA-AMC CPG.0 CPG.1 2009 NVL Ormazabal 20 Primary Distribution Switchgear Gas Insulation CPG System CPG.0 Cubicles Gas Insulation (SF6) Single busbar Technical Characteristics Rated voltage: Max. rated busbar current: Max. rated outgoing feeder current: Max. short time current: 2009 24 kV / 36 kV Up to 1600 A / Up to 1600 A Up to 1600 A / Up to 1250 A 25 kA/3s / 25 kA/3s Ormazabal 21 Primary Distribution Switchgear Gas Insulation CPG System CPG.1 Cubicles Gas Insulation (SF6) Single and Double Busbar Technical Characteristics Rated voltage: Max. rated busbar current: Max. rated outgoing feeder current: Max. short time current: 2009 24 kV / 36 kV Up to 2000 A / Up to 2000 A Up to 2000 A / Up to 2000 A 31.5 kA/3s / 31.5 kA/3s Ormazabal 22 Primary Distribution Switchgear Air Insulation CPA-AMC System Air Insulation Metal Clad Technical Characteristics Rated voltage: Max. rated current: Max. short time current: 2009 Up to 17.5 kV Up to 2500 A 31.5 kA/3s Ormazabal 23 Primary Distribution Switchgear Circuit Breaker NVL Vacuum Circuit Breaker Technical Characteristics Rated voltage: Max. rated current: Max. short time current: 2009 12 / 17.5 / 24 kV 2500 / 2000 / 1600 A 40 kA 3 s / 31.5 kA 3 s / 25 kA 3s Ormazabal 24 Secondary Distribution Switchgear GA ormaLINK CGMCOSMOS CGM.3 GAE 2009 Ormazabal 25 Secondary Distribution Switchgear KL / T / DES CDB (Chinese market) EA 2009 Ormazabal 26 Secondary Distribution Switchgear Gas Insulation - Ring Main Units CGMCOSMOS System Ring Main Unit (Compact) Gas Insulation (SF6) Technical Characteristics Rated voltage: Max. rated current: Max. short time current: 2009 Up to 12 kV / Up to 24 kV Up to 630 A / Up to 630 A Up to 25 kA / Up to 20 kA Ormazabal 27 Secondary Distribution Switchgear Gas Insulation - Ring Main Units CGM.3 System Ring Main Unit (Compact) Gas Insulation (SF6) Technical Characteristics Rated voltage: Max. rated current: Max. short time current: 2009 Up to 36 kV Up to 630 A 20 kA Ormazabal 28 Secondary Distribution Switchgear Gas Insulation - Ring Main Units GA System Ring Main Unit (Compact) Gas Insulation (SF6) Technical Characteristics Rated voltage: Max. rated current: Max. short time current: 2009 Up to 24 kV Up to 630 A Up to 20 kA Ormazabal 29 Secondary Distribution Switchgear Gas Insulation - Modular Cubicles CGMCOSMOS System Modular / Extensible Cubicles Gas Insulation (SF6) Technical Characteristics Rated voltage: Max. rated current: Max. short time current: 2009 Up to 12 kV / Up to 24 kV Up to 630 A / Up to 630 A Up to 25 kA / Up to 20 kA Ormazabal 30 Secondary Distribution Switchgear Gas Insulation - Modular Cubicles CGM.3 System Modular / Extensible Cubicles Gas Insulation (SF6) Technical Characteristics Rated voltage: Max. rated current: Max. short time current: 2009 Up to 36 kV Up to 630 A 20 kA Ormazabal 31 Secondary Distribution Switchgear Gas Insulation - Modular Cubicles GAE System Modular / Extensible Cubicles Gas Insulation (SF6) Technical Characteristics Rated voltage: Max. rated current: Max. short time current: 2009 Up to 24 kV Up to 1250 A Up to 20 kA Ormazabal 32 Secondary Distribution Switchgear Air Insulation EA System Air Insulation Metal - Enclosed Technical Characteristics Rated voltage: Max. rated current: Max. short time current: 2009 Up to 24 kV Up to 630 A 20 kA / 1 s Ormazabal 33 Secondary Distribution Switchgear Air Insulation CDB Cable distribution box Chinese market Technical Characteristics Rated voltage: 2009 Up to 12 kV Ormazabal 34 Secondary Distribution Switchgear Components Switches KL type: Switch DES type: Earthing switch T type: Disconnector DES T KL 2009 Ormazabal 35 Secondary Distribution Switchgear Components ORMALINK Connecting set Patented by Ormazabal Applications: CGMCOSMOS System CGM.3 System 2009 Ormazabal 36 Transformer Substations PFU PF (EDF ) Preforma-PF 2009 Ormazabal 37 Transformer Substations CTO ormaBAT CTC (EDF) (Chinese market) TS PF-15 ormaSET 2009 Ormazabal 38 Transformer Substations Underground PFS 2009 Ormazabal 39 Transformer Substations minibLOK CTR miniSUB 2009 MB Ormazabal 40 Transformer Substations Prefabricated miniBLOK Compact Outdoor Technical Characteristics Rated voltage: Number of transformers: Power per transformer: 2009 12 /24 kV 1 ≤ 630 kVA Ormazabal 41 Transformer Substations Prefabricated miniSUB Compact Underground Technical Characteristics Rated voltage: Number of transformers: Power per transformer: 2009 12 /24 kV 1 ≤ 630 kVA Ormazabal 42 Transformer Substations Electric Compact Equipment MB Assembled in Factory Equipment: • • • • • MT cubicles Transformer CBT Interconnections Frame Technical Characteristics Rated voltage: Number of transformers: Power per transformer: 2009 12 /24 kV 1 ≤ 630 kVA Ormazabal 43 Transformer Substations Prefabricated CTR Rural applications Compact Outdoor Technical Characteristics Rated voltage: Number of transformers: Power per transformer: 2009 24 /36 kV 1 ≤ 250 kVA Ormazabal 44 Transformer Substations Prefabricated ormaSET Minimal visual impact Outdoor Non-walk-in type Technical Characteristics Rated voltage: Number of transformers: Power per transformer: 2009 12 / 24 / 36 kV 1 ≤ 1000 kVA Ormazabal 45 Transformer Substations Prefabricated ormaBAT ‘End of line’ type Outdoor Non-walk-in type Technical Characteristics Rated voltage: Number of transformers: Power per transformer : 2009 12 /24 kV 1 ≤ 160 kVA Ormazabal 46 Transformer Substations Prefabricated CTC ‘Under pole’ type It includes: • Transformer • LVB • Interconnections Technical Characteristics Rated voltage: Number of transformers: Power per transformer: 2009 12 / 24 / 36 kV 1 ≤ 250 kVA Ormazabal 47 Transformer Substations Prefabricated CTO Compact Outdoor Covered walk-in-type French market Technical Characteristics Rated voltage: Number of transformers: Power per transformer: 2009 24 kV 1 ≤ 630 kVA Ormazabal 48 Transformer Substations In Ormazabal's Enclosure PFU Concrete enclosure Monoblock Outdoor Technical Characteristics Rated voltage: Number of transformers: Power per transformer: 2009 12 / 24 / 36 kV 1 or 2 ≤ 1000 kVA Ormazabal 49 Transformer Substations In Ormazabal's Enclosure PREFORMA-PF PAC type Monoblock Outdoor French market Technical Characteristics Rated voltage: Number of transformers: Power per transformer: 2009 24 kV 1 ≤ 1000 kVA Ormazabal 50 Transformer Substations In Ormazabal's Enclosure PF Concrete enclosure Modular Outdoor Technical Characteristics Rated voltage: Number of transformers: Power per transformer: 2009 12 / 24 / 36 kV 1, 2, 3… ≤ 1000 kVA Ormazabal 51 Transformer Substations In Ormazabal's Enclosure PFS Concrete enclosure Monoblock Underground Technical Characteristics Rated voltage: Number of transformers: Power per transformer: 2009 12 / 24 / 36 kV 1 or 2 ≤ 1000 kVA Ormazabal 52 Transformer Substations Switching and Breaking Substations PF-15 Outdoor Non-walk-in type It only includes MV cubicles Technical Characteristics Rated voltage: 2009 12 /24 kV Ormazabal 53 Distribution Transformers Up to 160 kVA From 25 kVA to 160 kVA 24 kV / 36 kV Liquid dielectric Usage: Indoor Outdoor On pole Technical Characteristics Power: Primary Voltage: Secondary Voltage: 2009 From 25 to 160 kVA Up to 36 kV 420 V Ormazabal 54 Distribution Transformers Up to 2500 kVA From 250 kVA to 2500 kVA 24 kV / 36 kV Liquid dielectric Usage: Indoor Outdoor Technical Characteristics Power: Primary Voltage: Secondary Voltage: 2009 From 250 to 2500 kVA Up to 36 kV 420 V Ormazabal 55 Low Voltage Boards 2009 Ormazabal 56 Low Voltage Boards Metallic Enclosure AC4+AM4 Up to 4 outputs Extension module + 4 outputs AC5 Up to 5 outputs AC6 Up to 6 outputs Technical Characteristics 2009 AC4+AM4 AC5 /AC6 Rated Voltage: 440 V 440 V Rated Current: 1600 A 1000 A Ormazabal 57 Low Voltage Boards Optimised Low Voltage Board CBTO Up to 8 outputs Disconnector included Technical Characteristics of the disconnector Operation Type: Rated Voltage: Rated Current: 2009 Dependent manual 440 V 1000 A /1600 A Ormazabal 58 Ormazabal Protection & Automation ekorSYS family Protection Protections for Switching and Private Industrial Substations MV customer supply ekorRPG 2009 ekorRPT ekorRPS Ormazabal Protection for Rural TS ekorRPT-K 59 Ormazabal Protection & Automation ekorSYS family Automation Automatic transfers Remote control Fault detection Voltage presence acoustic alarm ekorCCP ekorUCT 2009 ekorRCI ekorSTP Ormazabal ekorDPF ekorSAS 60 Renewable Energy Application Applications for Wind Farms 2009 Ormazabal 61 Renewable Energy Application Applications for Solar Installations CFI Integrated Photovoltaic Substation It includes: Concrete enclosure Transformer substation Inverter compartment 2009 Ormazabal 62 Development, manufacture, commercialisation and maintenance of products and applications based on Medium Voltage Power Electronics 2009 Products: Target Market: - Voltage regulation - Reactive energy compensation - Static circuit-breakers - Converters - UPS - Utilities - Power generation - Industry - Telecommunications - Railway - Other Ormazabal 63 2009 Ormazabal 64 SOLID-STATE BREAKER COMPENSATED VOLTAGE, POWER FACTOR, HARMONICS, , SENSITIVE LOAD SOLID-STATE CURRENT LIMITER DSTATCOM Reduced transients and harmonics ENERGY STORAGE DYNAMIC NON-LINEAR LOAD DVR SENSITIVE LOAD ENERGY STORAGE Continuous duty SSTS CRITICAL LOAD 2009 Ormazabal 65 Locations Production Zhuhai - China Krefeld - Germany Beijing - China 2009 Ormazabal 66 Locations Madrid - Spain Zamudio - Spain Igorre - Spain 2009 Ormazabal 67 Locations Production Torcy - France Toledo - Spain Malaga - Spain 2009 Ormazabal 68 Locations Ormazabal Corporate Technology March 2008 High Power Laboratory for testing MV switchgear up to 2500 MVA 2009 Ormazabal 69 Locations Commercialisation 2009 Ormazabal 70 Some examples • HORNS REEF Offshore Wind Farm - Denmark • NORTH HOYLE Offshore Wind Farm - U.K. • Gottard tunnel - Switzerland • Larnaca desalination plant - Cyprus • Lotsburg tunnel - Switzerland • President M. Ben Ali Royal Palace - Tunisia • Headquarters of Spanish Utilities • Argentina National Treasury Headquarters • Ministro Pistarini Airport in Buenos Aires - Argentina • Bangkok New Airport - Thailand • Liceu and National Theatre of Barcelona - Spain • Sports City of Real Madrid - Spain • AVE, Spain high-speed rail • Lehrter Bahnhof, Berlin railway station - Germany • Langer Eugen, Bonn (Telekom) - Germany • Tiananmen Square - China • Oriental Pearl Tower in Shanghai - China • Daya Bay Nuclear P.S. - China • People’s Congress Hall of Nanning - China • Guangzhou University City - China • Zhuhai Airport - China • ... 2009 Ormazabal 1.000.000 1.000.000 f.u. f.u. of of primary primary and and secondary secondary distribution distribution installed installed on on the the 55 continents. continents. Other worldwide references • Airports • Hospitals • Military installations • Theme parks • Museums • Universities • Research Centres • Undergrounds / Metros • Hotels • Sports facilities 71 Other Activities Polsa / ASSL SMC/BMC Tecnichapa Polyester moulders High precision sheet metal parts www.tecnichapa.es www.polsa.com Ribate Tecnoexpress 2009 Physical security Engineering & Consultancy www.tecnoexpress.com www.ribate.com Barik Knock Telecom Telecommunications Solutions Telecommunications Equipment www.barik.es www.knocktelecom.com Ormazabal 72 Other Activities Polsa Solutions in SMC/BMC polyester moulders www.polsa.com 2009 Ormazabal 73 Other Activities Tecnoexpress Physical security systems http://www.tecnoexpress.es 2009 Ormazabal 74 Other Activities Tecnichapa Global solutions in high precision sheet metal parts www.tecnichapa.com 2009 Ormazabal 75 Other Activities Knock Telecom Equipment for telecommunications www.knocktelecom.com 2009 Ormazabal 76 Other Activities Ribate Engineering and consultancy www.ribate.com 2009 Ormazabal 77 Other Activities Barik Solutions for telecommunications www.barik.es 2009 Ormazabal 78 2009 Ormazabal 79
Similar documents
ORMAZABAL uk Welcome to
We encourage the development of the electrical sector towards the challenges of the future energy needs. We cooperate with the world’s leading local, regional and global companies in the electrical...
More informationORMAZABAL centRAL And SOUtH AFRIcA Welcome to
challenges of the future energy needs. We cooperate with the world’s leading local, regional and global companies in the electrical sector with a strong commitment to innovation towards personal sa...
More information