company profile
Transcription
company profile
COMPANY PROFILE Ganges group is a multi faced professionally managed organization, dealing in different fields of manufacturing. The group has interest & strong presence in di ersified field like solar turnkey diversified t rnke projects, projects telecom turnkey t rnke projects, projects steel tubes t bes & pipes, heavy fabrication, roller flour mills, bread manufacturing. The Group turnover is over 1000 cr. with employee strength of over 1500. The Group is thinking of newer Horizon and our working harmoniously to achieve excellence under effective guidance of highly experienced and integrated top management. Ganges Internationale (P) Ltd is Primarily a Construction Company, having interest in design, manufacturing and erection of Pre Engineered Buildings (PEB), Solar panel mounting structure, telecom structure. The Company have two plants one at Pondicherry & another at Raipur with modern equipments, having facilities for manufacturing complete range of PEB, solar panel mounting structure & telecom structure. We are leading manufacturers of Pre Engineered Buildings. We are equipped with latest machinery and equipments. We have in house manufacturing capabilities to fabricate all type of structures. We have indigenously developed and manufactured these products under stringent quality checks at every stage of production to achieve best performance standards. We are setting up one more facility in Raipur with the capacity for Production of 30000 MT of PEB per Annum. Production will be started by the year end. Objectives: Customer satisfaction Maintain Highest Quality Standards Maintain pace with Technology Advent Offering a Solution to every need under one roof Turnkey Responsibility: Single source integrated solutions Design Engineering Procurement Supply & Installation Our core values are: Integrity Commitment Excellence Pre Engineered Building Components: Primary Members: – Columns, Rafters, Frames, (Hot Rolled / Built up Sections) Bracings Purlins, Purlins Girts, Girts (Cold formed Sections) Roof & Wall Secondary Members – Bracings, Cladding – Roofing, Cladding, PU Sandwitched panels, Flashings (Ridge, Gutter etc) Accessories: - Anchor Bolts, Fasteners, Connectors. Optional Extra: – Fascia, Canopies, louvers, Skylights, Crane Gantry, false Ceilings, Mezzanine, Turbovents. Applications of Pre Engineered Buildings: •Warehouses •Factories •Cold Stores •Offices, Schools, Hospitals, Site Offices •Gas Stations, Bus Shelters, Car Parks •Commercial C i lC Complexes, l Sh Shopping i M Malls ll •Aircraft Hangars •Sports and other recreational facilities •Metro / Railway Stations DETAILS OF DESIGNING AND DRAFTING FACILITIES Applicable Codes:Loads are applied in accordance with: •The 2005 Edition of Low Rise Building System Manual •Metal Building Manufacturers Association (MBMA) p sections are designed g in accordance with: Hot rolled and Built up •Manual of Steel Construction, 9th Edition •American Institute of Steel Construction (AISC) Cold-formed members are designed in accordance with: •1996 1996 Edition of Cold formed Steel Design Manual •American Iron and Steel Institute (AISI) Welding is applied in accordance with: •American Welding Society (AWS D1.1.98) Structural Welding Code – Steel Loads on all buildings are applied in accordance with: IS-875 (Part-I) – 1987: Code of Practice for Design Dead Loads for Building and Structures. IS-875 (Part-II) – 1987: Code of Practice for Design Imposed Loads for Building and Structures. IS-875 (Part-III) – 1987: Code of Practice for Design Wind Loads for Building and Structures. IS-1893 (Part-I) – 2002: Criteria for Earthquake Resistance Design of Structures. Design of prismatic Hot Rolled and Built up sections is in accordance with: IS-800 ((1984): ) Code of Practice for general g Construction in Steel. Cold – Formed members are designed in accordance with: IS-801 (1975): Code of Practice for use of Cold –Formed Light Gauge Steel Structure. Welding is applied in accordance with: Structure Steel Welding Code of American Welding Society (AWS D1.1.98) IS-816 (1969): Code of Practice for use of Metal Arc Welding for general construction in steel. l DESIGN FACILITY: IN HOUSE. CODES FOLLOWED, “IS”/“ASIC” AND AS PER MBMA. Auto Cad is being used for Designing/Drafting. Plant Details Plant No‐1:‐Pondicherry Area: 18 Acre Plant No‐2:‐Raipur Area: 5 Acre Ganges Purlins Advantage oSaving upto 35 35-40% 40% in weight and 20% in cost when compared to hot rolled purlins. oTruss spacing can be increased, hence less numbers of trusses columns and foundation work resulting in further economy. oThe purlins are supplied in required lengths with pre-punched holes. hence, reduction in constrained time and cost in fabrication & erection and no wastage. oPurline erection is easier than oyhers. oClose tolerances on sectional dimensions due to process of cold roll forming. oLow o o transportation t a spo tat o cost due to reduced educed weight. oHigh versatility, durability and uniform quality. Plant No‐3:‐Raipur Area: 23 Acre Under Construction Types of Frames Roofing and Wall Cladding GANGES HI‐RIB PROFILE GANGES Hi Rib profile is developed to provide GANGES Hi‐Rib profile is developed to provide scientific solution for roof & side walls of industrial as well as commercial buildings. GANGES Hi‐Rib is provided with a precisely engineered wide Rib & flute design to ensure wide spanning & quick recovery after being subjected to excessive load. GANGES KLIPPON GANGES Klippon is stiffened trapezoidal profile with wide spanning capability. it is suitable for roofing application on very long roofs down to fi li i l f d 2 pitch. its bold profile and broad flat outline makes a strong and striking appearance. GANGES SS‐2000 This is field seamed system that combines a slim rib with exceptional uplift resistance. This panel has been designed to withstand This panel has been designed to withstand the most rigorous conditions for data details and fixing procedures, please refer to GANGES Metal Roofing & SSR catalogues. Building Accessories Sliding Doors GANGES standard double/single sliding doors are of size 4.0 X 4.0 M. We are also equipped to offer any size up to 8.0 X 6.0 M as per customers' requirements. Louvers GANGES standard louvers are of size 2.0 M long X 0.60 M wide. Sky Lights and Wall Lights Sky Lights and Wall Lights GANGES standard sky lights/wall lights come in two variations, either in FRP or Polycarbonate of 1.5 mm thi k thickness and size 1.0 M X 3.0 M. d i 10MX30M Building Accessories Ridge Ventilators GANGES standard ridge ventilators are of 0.3 M throat width and can be supplied either continuous or in modules of 3.0 M length. Roof Jacks & Curbs Roof jacks are available in opening sizes from 50 ‐300 mm dia and roof curbs are available in 900 mm square, and are used for fixing powered ventilators supplied by others. PLANT AND MACHINERY LIST OF PLANT AND MACHINERY THANKS For Ganges Internationale Pvt. Ltd Corp Office: B‐36,Lawrence Road Industrial Area New Delhi‐110035 Tel No 011 45870565 Tel No.‐011‐45870565 Fax No.‐011‐47451135 Mob No‐8826663815 E‐mail‐[email protected] Web:www.gangesintl.com g g