company profile

Transcription

company profile
COMPANY PROFILE
Ganges group is a multi faced professionally managed organization, dealing in
different fields of manufacturing. The group has interest & strong presence in
di ersified field like solar turnkey
diversified
t rnke projects,
projects telecom turnkey
t rnke projects,
projects steel tubes
t bes
& pipes, heavy fabrication, roller flour mills, bread manufacturing. The Group
turnover is over 1000 cr. with employee strength of over 1500. The Group is
thinking of newer Horizon and our working harmoniously to achieve excellence
under effective guidance of highly experienced and integrated top management.
Ganges Internationale (P) Ltd is Primarily a Construction Company, having
interest in design, manufacturing and erection of Pre Engineered Buildings
(PEB), Solar panel mounting structure, telecom structure.
The Company have two plants one at Pondicherry & another at Raipur with
modern equipments, having facilities for manufacturing complete range of PEB,
solar panel mounting structure & telecom structure.
We are leading manufacturers of Pre Engineered Buildings. We are equipped with latest machinery
and equipments. We have in house manufacturing capabilities to fabricate all type of structures. We
have indigenously developed and manufactured these products under stringent quality checks at
every stage of production to achieve best performance standards. We are setting up one more
facility in Raipur with the capacity for Production of 30000 MT of PEB per Annum.
Production will be started by the year end.
Objectives:
Customer satisfaction
Maintain Highest Quality Standards
Maintain pace with Technology Advent
Offering a Solution to every need under one roof
Turnkey Responsibility:
Single source integrated solutions
Design
Engineering
Procurement
Supply & Installation
Our core values are:
Integrity
Commitment
Excellence
Pre Engineered Building Components:
Primary Members: – Columns, Rafters, Frames, (Hot Rolled / Built up Sections)
Bracings Purlins,
Purlins Girts,
Girts (Cold formed Sections) Roof & Wall
Secondary Members – Bracings,
Cladding – Roofing, Cladding, PU Sandwitched panels, Flashings (Ridge, Gutter etc)
Accessories: - Anchor Bolts, Fasteners, Connectors.
Optional Extra: – Fascia, Canopies, louvers, Skylights, Crane Gantry, false Ceilings,
Mezzanine, Turbovents.
Applications of Pre Engineered Buildings:
•Warehouses
•Factories
•Cold Stores
•Offices, Schools, Hospitals, Site Offices
•Gas Stations, Bus Shelters, Car Parks
•Commercial
C
i lC
Complexes,
l
Sh
Shopping
i M
Malls
ll
•Aircraft Hangars
•Sports and other recreational facilities
•Metro / Railway Stations
DETAILS OF DESIGNING AND DRAFTING FACILITIES
Applicable Codes:Loads are applied in accordance with:
•The 2005 Edition of Low Rise Building System Manual
•Metal Building Manufacturers Association (MBMA)
p sections are designed
g
in accordance with:
Hot rolled and Built up
•Manual of Steel Construction, 9th Edition
•American Institute of Steel Construction (AISC)
Cold-formed members are designed in accordance with:
•1996
1996 Edition of Cold formed Steel Design Manual
•American Iron and Steel Institute (AISI)
Welding is applied in accordance with:
•American Welding Society (AWS D1.1.98)
Structural Welding Code – Steel
Loads on all buildings are applied in accordance with:
IS-875 (Part-I) – 1987: Code of Practice for Design Dead Loads for Building and Structures.
IS-875 (Part-II) – 1987: Code of Practice for Design Imposed Loads for Building and Structures.
IS-875 (Part-III) – 1987: Code of Practice for Design Wind Loads for Building and Structures.
IS-1893 (Part-I) – 2002: Criteria for Earthquake Resistance Design of Structures.
Design of prismatic Hot Rolled and Built up sections is in accordance with:
IS-800 ((1984):
) Code of Practice for general
g
Construction in Steel.
Cold – Formed members are designed in accordance with:
IS-801 (1975): Code of Practice for use of Cold –Formed Light Gauge Steel Structure.
Welding is applied in accordance with:
Structure Steel Welding Code of American Welding Society (AWS D1.1.98)
IS-816 (1969): Code of Practice for use of Metal Arc Welding for general construction in
steel.
l
DESIGN FACILITY:
IN HOUSE. CODES FOLLOWED, “IS”/“ASIC” AND AS PER MBMA. Auto Cad is
being used for Designing/Drafting.
Plant Details
Plant No‐1:‐Pondicherry
Area: 18 Acre
Plant No‐2:‐Raipur
Area: 5 Acre
Ganges Purlins Advantage
oSaving upto 35
35-40%
40% in weight and 20% in
cost when compared to hot rolled purlins.
oTruss spacing can be increased, hence less
numbers of trusses columns and foundation
work resulting in further economy.
oThe purlins are supplied in required lengths
with pre-punched holes. hence, reduction in
constrained time and cost in fabrication &
erection and no wastage.
oPurline erection is easier than oyhers.
oClose tolerances on sectional dimensions
due to process of cold roll forming.
oLow
o
o transportation
t a spo tat o cost due to reduced
educed
weight.
oHigh versatility, durability and uniform
quality.
Plant No‐3:‐Raipur
Area: 23 Acre
Under Construction
Types of Frames
Roofing and Wall Cladding
GANGES HI‐RIB PROFILE
GANGES Hi Rib profile is developed to provide
GANGES Hi‐Rib profile is developed to provide scientific solution for roof & side walls of industrial as well as commercial buildings. GANGES Hi‐Rib is provided with a precisely engineered wide Rib & flute design to ensure wide spanning & quick recovery after being subjected to excessive load.
GANGES KLIPPON
GANGES Klippon is stiffened trapezoidal profile with wide spanning capability. it is suitable for roofing application on very long roofs down to fi
li i
l
f d
2 pitch. its bold profile and broad flat outline makes a strong and striking appearance.
GANGES SS‐2000
This is field seamed system that combines a slim rib with exceptional uplift resistance. This panel has been designed to withstand
This panel has been designed to withstand the most rigorous conditions for data details and fixing procedures, please refer to GANGES Metal Roofing & SSR catalogues.
Building Accessories
Sliding Doors
GANGES standard double/single
sliding doors are of size 4.0 X 4.0 M.
We are also equipped to offer any
size up to 8.0 X 6.0 M as per
customers' requirements.
Louvers
GANGES standard louvers are of size 2.0 M long X 0.60 M wide. Sky Lights and Wall Lights
Sky
Lights and Wall Lights
GANGES standard sky lights/wall lights come in two variations, either in FRP or Polycarbonate of 1.5 mm thi k
thickness and size 1.0 M X 3.0 M. d i 10MX30M
Building Accessories
Ridge Ventilators
GANGES standard ridge ventilators are of 0.3 M throat width and can be supplied either continuous or in modules of 3.0 M length.
Roof Jacks & Curbs
Roof jacks are available in opening sizes from 50 ‐300 mm dia and roof curbs are available in 900 mm square, and are used for fixing powered ventilators supplied by others.
PLANT AND MACHINERY
LIST OF PLANT AND MACHINERY
THANKS
For
Ganges Internationale Pvt. Ltd
Corp Office: B‐36,Lawrence Road Industrial Area
New Delhi‐110035
Tel No 011 45870565
Tel No.‐011‐45870565
Fax No.‐011‐47451135
Mob No‐8826663815
E‐mail‐[email protected]
Web:www.gangesintl.com
g g