TANSA GÜVENLİK SİSTEMLERİ ve SAAT SAN. TİC. A.Ş.
Transcription
TANSA GÜVENLİK SİSTEMLERİ ve SAAT SAN. TİC. A.Ş.
TANSA GÜVENLİK SİSTEMLERİ ve SAAT SAN. TİC. A.Ş. SG-312 / SG-112 / SGWMC / LTT343 VIP SWING GATES OPERATION & MAINTANANCE MANUAL SG-312 SG-112 SGWMC LTT-343 SWING GATES Contents 1 2 3 4 5 6 Introduction 1.a 1.b 1.c 1.d Page General Information Safety Warnings Hardware Modifications Packing Contents 1 1 1 1 Technical Specifications 2.a General Description 2.b Technical Specifications Chart 2.c Dimentions 2.d Options and Standart Specifications 2 3 4 6 Installation 3.a 3.b 3.c 3.d 3.e 3.f 3.g 7 7 7 8 10 11 13 Unpacking Wiring Field Arrangement and Positioning Arm & Wing Installation Ground Installation Electrical Connections Synchronization of Two Swing Gates Mechanical & Electronical Specifications 4.a Opening the Lid 4.b Mechanism and Components 4.c Control Board and Specifications 4.d Setting Modes 14 15 16 17 Instructions for Use 5.a Usage 5.b Operating Modes 5.c Operating System Specifications 18 18 19 Maintanance 6.a Cleaning 6.b Maintanance 20 20 SWING GATES 1 Introduction 1.a General Information Please read this manual carefully before installation. This manual includes information about installation and maintanance for a long life-time of the product. TANSA have rights to make mechanical and electrical equipment changes on products so there can be minor differences between the information on operations manual and delivered products. OR TANSA reserves the right to make changes on the products. The products on the data sheets may have been upgraded or changed therefore may not reflect the units. 1.b Safety Warnings - The access keys to the mechanism must only be used by staff who have been informed of the electrical and mechanical risks that they would run in the event of negligent manipulation. - Before opening the housing, cut off the power supply. - Any internal element that could be live or in movement must be handled with care. - The equipment has been configurated in "minimum risk" for its users. Installation, settings and changings must be carried out with full knowledge of the facts by qualified personnel and shall in no way invoke any liability for TANSA. 1.c After Sales Modifications If there will be a modification, component adding or changing, TANSA should be informed for confirmation. Additional information can be needed and will be provided by TANSA. 1.d Packing Contents a- 1 Unit SG-112/SG-312/SGWMC/LTT-343 swing gate. b- 1 Unit 81cm arm (SG-312) b- 1 Unit 80cm wing (SG-112) b- 1 Unit 80cm wing (SGWMC) b- 3 Units Glass wing (LTT-343) c- 1 Unit Key (SG-112 / SG-312) d- 2 Units Guidance sticker e- Installation & Operating Manuel SWING GATES 2 SPECIFICATIONS 2.a General Discriptions Drive Bi-directional, electronic controlled and motorized opening and closing. Cabinet/Housing AISI 304 (EN10082-2Grade 1G/2G) stainless steel. Arms & Wings Clear acrylic in 10 mm thickness (SG-112, SGWMC, LTT-343) Aluminium (SG-312) Operating Modes Time setting for automatic closing or closing by a push button. Mechanism All mechanism parts are located at the monobloc body. body. Power Supply 220 VAC 50/60Hz, optional 110VAC Power Consumption 17/30 Watt Control Board PSU 12VDC / 24VDC Power Failure & Emergency Full integration with fire or alarm systems allowing automatic sate-free (fail-safe) mode in case of emergency or power failure (standard feature) Operating Temperature -10 to +55°C Shipping & Storage Temperature -20 to +55° C Operating Humidity 95% Max. SWING GATES 2.b Technical Specifications You can find the below table regarding the technical specifications of swing gates. MODEL MECHANISM CONTROL BOARD HEIGHT CABINET DIMENTIO WEIGHT POWER COMSUMP. OPERATING TEMP. POWER SUPPLY SG-112 VIP02v4 ECB-201R03 1050 mm 320X200 mm 35kg max. 30 watt - 10°, +55° 220 VAC/50 Hz SG-312 VIP02v4 ECB-201R03 1050 mm 320X200 mm 31kg max. 30 watt - 10°, +55° 220 VAC/50 Hz SGWMC VIP04v2 ECB-201R03 1000 mm 170x170 mm 42kg max. 30 watt - 10°, +55° 220 VAC/50 Hz LTT-343 VIP01v2 ECB-201R03 1000 mm 170x170 mm 73kg max. 30 watt - 10°, +55° 220 VAC/50 Hz * All dimentions in milimeters. * Standard arm length for SG-312 is 810 mm. Optional 1000 mm arm is available. * Standard arm length for SG-112 is 800 mm. Optional 900 mm arm is available. * Standard arm length for SGWMC is 800 mm. Optional 950 mm arm is available. * All products can me manufactured in mild steel and powder coated upon request. SWING GATES 2.c Dimensions SWING GATES SWING GATES 2.d Optional Accessories OPTIONAL ACCESSORIES MODEL SG-112 SG-312 SGWMC LTT-343 OPTIONAL OPTIONAL OPTIONAL -- AUTOMATI SECURITY C OPENING PHOTOCEL COUNTER PHOTOCEL L L OPTIONAL -OPTIONAL OPTIONAL OPTIONAL OPTIONAL -- OPTIONAL -- OPTIONAL OPTIONAL -- OPTIONAL -- OPTIONAL -- OPTIONAL OPTIONAL -- OPTIONAL STANDARD -- OPTIONAL -- REMOTE AUTOMATI BUTTON CONTROLL C OPENING CONTROL ER SENSOR BOX GLASS WING Remote Controller: Can be used to control all automatic swing gates. Open and Close functions can be controlled seperately by two different buttons. Automatic Opening Sensor: Can be used to control SG112 and SG312 swing gates in entrance and exit directions seperately. For each direction a small ultrasonic sensor is mounted on the body to sense the pedestrians from 20 cm up to 1 meter distance. Button Control Box: Can be used to control all automatic swing gates. With two push buttons (NO) Open and Close functions can be controlled seperately. Up to 5 different swing gates can be controlled. Glass Wing: Glass wing is standard in LTT-343 model. It is not used for other swing gates because of its weight. Security Photocell: Can be used in all models except LTT-343. This sensor prevents closing if there is a pedestrian who stands in front of the closed arm position. Also during closing, if a pedestrian comes to the closed arm position, the arm will stops and re-opens in order to prevent hitting. This sensor consists two seperate parts. Transmitter and the reflector. Counter: Can be used only in LTT-343 model to count the total passages in every direction. Automatic Opening Photocell: Can be used in all models except LTT-343. This sensor consists two seperate parts. Transmitter and the reflector. Both parts should be installed face to face from any distance to swing gate to maintain a corridor. Wiring needed between the transmitter and the swing gate. The sensor senses the pedestrian when he/she passes through the transmitter and reflector, and the gate will opened automatically. SWING GATES 3 INSTALLATION 3.a Unpacking Please check the swing gate visually after unpacking. If any damage or missing part is realized place contact with TANSA. 3.b Wiring 3x1.5mm power cable and 5A fuse needed for operating. 10A fuse recommended for earth. Data cables should run on a different line than electrical cables. 3.c Placing the Swing Gate Ground should be flat. The body should be installed first and the arms later. 50 mm distance recommanded between the swing gate and any other object around (See Part 3.e). It is optional to leave the distance more or less than that. Steel or chemical dowel should be used for ground connections. SWING GATES 3.d Arm & Wing Installation SG 112 1. Remove the bolts on the compression section. 2. Place the acrylic wing between the compression section and the gate body. 3. Screw on the bolts tightly. SG 312 1. Remove the M4 socket cap bolts. 2. Place the aluminium arm through the arm support grip. 3. Screw on the M4 socket cap bolts tightly. SWING GATES SGWMC 1. Pull and remove the top lid. 2. Remove the bolts on the compression section. 3. Place the acrylic wing between the compression sections. 4. Screw on the bolts tightly. 5. Wear the top lid by pushing SWING GATES 3.e Ground Installation SG112 / SG312: 1. Place the swing gate to its installation position. 2. Mark around bottom of the body. 3. Remove the swing gate 4. Remove the M6 socket head bolts to release the installation plate. 5. Place the installation plate on the marked surface. 6. Mark the installation holes. 7. Drill the ground from marked spots. 8. Bolt down the installation plate. 9. Place the swing gate on the installation plate and thighten the M6 socket head bolts. 2mm Distance SGWMC / LTT-343: 1. Remove the upper part of the body from the bottom part 2. Remove the bottom part from the frame which is welded to installation plate. 3. Mark and drill the installation holes. 4. Place the bottom part of the body and screw on to the frame. 5. Complete the wiring. 6. Place the upper part of the body and screw on tightly. Drw 3 Drw 1 Drw 4 Drw 2 Drw 5 Drw 6 SWING GATES 3.f Electrical Connections (External Connections) 1 1- +24 VDC1 2- GND2 3- +12 VDC2 4- GND1 1- +24VDC Out 2- Direction A-B control input (NO) 3- Direction B-A control input (NO) 4- Optional Input 5- Emergency input (NC) 6- GND 1- +24VDC Out 2- Security photocell input 3- Optional input 4- Optional input 5- Direction switch input 6- GND 1- Direction A output COM 2- Direction A output NO (SG343) 3- Direction B output COM 4- Direction B output NO (SG343) 5- Optional output COM 6- Optional output NO - NO relays or PNP should be connected for direction control inputs. - NC relays should be connected for emergency input. On J17 terminal #1 and #2 should be connected by short-circuit if there will be no emergency control. SWING GATES Direction Control Inputs (NO) Direction Control Inputs (+9/24VDC) J17 + OUT + A-B Reader J17 + - OUT + A-B B-A B-A Reader NC Emergency Input Connection (If not used connect with a shortcircuit) Counter Input SG343 J18 J19 Drawing shows a counter connection on direction A-B. For a counter on B-A direction use #3 and #4 of the J19 terminal. Counter 24VDC SWING GATES 3.g Synchronization of Two Swing Gates For synchronization of two swing gates which placed face to face below connections required. Control Board (1st swing gate) Control Board (2nd swing gate) !!! SHOULD NOT BE CONNECTED A-B Direction B-A Direction Control Input Control Input (NO) (NO) + - D 24VDC PNP NO Security Photocell !!! SHOULD NOT BE CONNECTED A-B Direction Control Input (NO) + - D 24VDC PNP NO Free passage sensor SWING GATES 4. Mechanical & Electronical Specifications 4.a Openning the Lid (SG-112 / SG-312) 1 2 1. Unlock the lid by turning clockwise. 2. Pull the front part of the lid 1/2 cm. 3. Push the lid to the back side. 4. Pull the complete lid up. 3 4 SWING GATES 4.b Mechanism SG112 / SG312 1 14 2 3 3 12 4 5 11 7 8 10 9 15 6 1- A-B direction locking solenoid 2- B-A direction locking solenoid 3- Solenoid bracket 4- Motor 5- Motor mounting and streching bracket 6- Motor belt 7- Rotor pulley 8- Sensor plate 9- Sensor mounting plate 10- Optical sensor 11- Lock arm 12- Lock arm spring 13- Motor strecher spring 14- Main mechanism plate 15- Motor pulley 10 13 SWING GATES 4.c Control Board & Specifications - Green led ligh always flashes if the microprocessor is on. - Red led lights always on and shows the power is on. - The barcode on the microprocessor should never removed. The barcode defines the version and operatioanl mode of the control board. ECB-201 R03 Swing Gate Control Board 13 4 3 2 1 6 5 11 10 14 1 7 8 9 1- Control Board Main Power Input 24VDC / 12VDC 2- Swing speed control relay connection 3- Not used 4- Not used 5- A-B direction solenoid output 6- B-A direction solenoid output 7- Control inputs 8- Optional input 9- Counter output relay NO kontak (SG343) 10- Power voltage selection for control 11- Rotation sensor input 12- PC communication port (TTL Optional) 13- Mode setting switches 14-Motor connector SWING GATES 4.d Sw1 - Sw2 Setting Modes Automatic Closing Time Setting Sw1 ON - Sw2 ON Sw1 OFF - Sw2 ON Sw1 ON - Sw2 OFF Sw1 OFF - Sw2 OFF Sw3 - Sw4 Sw5 Direction Control Sw3 ON Sw3 OFF Sw4 ON Sw4 OFF 20 seconds 15 seconds 10 seconds 5 seconds A-B direction controlled A-B direction free B-A direction controlled B-A direction free Not Used Sw5 ON Sw5 OFF After the gate is completely opened, an automatic closing time can be set. These switches are not used. Should always be ON position. Not used. Can be on ON or OFF position. Sw6 Automatic Closing Setting Sw6 ON Automatic closing active When the automatic closing is active, the Sw6 OFF Automatic closing passive gate will be closed automatically after the set time. When the automatic closing is passive, control signal needed (E.G.push button) for closing the gate. Sw7 Minumum control input signal time Sw7 ON 200mS Sw7 OFF 20mS Control input signal Sw8 Warning Voice Control Sw8 ON Warning voice ON Sw8 OFF Warning voice OFF If the control input signal time is too short or several control signals received for group entrances or exits, switch should be in OFF position. For standard use, switch should be in ON position. If the switch is ON position, after receiving an OPEN signal, a continious "beep tone" is heard. SWING GATES 5 Instructions for Use 5.a Usage Any kind of access control system can be easily connected to swing gate (card or biometric readers, push botton, remote controller, coin or token acceptor... etc). Do not push or pull the arm during operation. Do not put anything such as purse, suitcase etc. on the gate cabinet. Swing gates are fail-safe during emergency or power failure. 5.b Operating Modes Swing gates are fail-safe during emergency or power failure (Standard) Swing gates are fail-locked during emergency or power failure (Optional) SWING GATES 5.c Operating System Specification Swing gates have full control in both directions by a microprocessor controller and can be easily connected to any kind of access control system (card or biometric readers, push botton, remote controller, coin or token acceptor... etc). Can remain OPEN for allotted times. Double units can be controlled syncronised in face to face installation in order to prevent larger entrances or exits. MODEL MECHANICAL SYS. MANUEL OPERATING SYSTEM MATERIAL SPECIFICATION MOTOR DRIVE LOCKING BRAKE CABINET/HOUSING ARMS/WINGS SHAFT SG112 YES Motor Solenoid Electronic Stainless /Powder Coated 10mm Acrylic Stainless SG312 YES Motor Solenoid Electronic Stainless /Powder Coated 10mm Acrylic Stainless SGWMC YES Motor Solenoid Electronic Stainless /Powder Coated 10mm Acrylic Stainless LTT-343 YES Pushing/Motor Solenoid Electronic Stainless /Powder Coated 10mm Tempered Glass Stainless SWING GATES 6 Maintanance 6.a Cleaning Periodical body, arm and wing cleaning is recommanded. Cleaning supplies that contain acidic chemicals might damage AISI 304 stainless steel and leave a stain on it. Please use liqued cleaners that contain soft chemicals such as stainless steel or window cleaning sprays. 6.b Maintanance Dust and dirt can effect the life-time of the mechanism. Mechanizm should be cleaned periodically. - Before opening the housing, cut off the power supply. SWING GATES *TANSA reserves the right to modify design and details. Address Abdurrahman Gazi Mah. Alparslan Cad. Selma Sok. No:2 34887 Sancaktepe – Istanbul TURKEY Telephones +90 216 561 96 71-72-73 Fax +90 216 561 96 74-75