3 - BMWi
Transcription
3 - BMWi
Power Plant Solutions – Extreme Conditions Global Technical Consulting & Projects Agenda – Product Portfolio 1 Utility-grade PV in the multi-megawatt range 2 Extreme conditions require special solutions 3 Demanding stress tests for extreme conditions SMA Solar Technology AG 2 Power Plant Solutions – Inverter and system solutions ... 900 800 500 Max. AC Power (kW) Commercial and Utility grade 8, 10, 12, 15.17, 20 TL Utility grade Global Market 500 CP XT/JP 630 720 760 800 850 900 CP XT Utility grade UL-certified 500 SMA Solar Technology AG 630 720 750 800 CP-US 3 Power Plant Solutions – Inverter and system solution for all plant design ... 500 800 1000 1250 1600 1800 Max. AC Power (kW) Walkable 500MV 630MV TCS500 TCS630 800MV 1000MV 1250MV 1600MV Outdoor TCS800 TCS1000 TCS1250 TCS1600 TCS1800 US Skid Enclosure Skid Canopy Skid Open The complete product range for utility scale PV-plant SMA Solar Technology AG 4 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Substation optimized in terms of cost and technology SUNNY CENTRAL MV SUNNY CENTRAL CP XT 30t 1.9t incl. MV transformer incl. MV transformer substation, approx. 5t SMA Solar Technology AG 5 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Easy handling – less weight and size > Outdoor enclosure with IP 54 > Direct deployment in the field > Easy transport & handling in the field > Easy installation due to a separate connection area > Reduced weight > No special equipment for unloading in the field (cranes & trucks) > Less effort for construction roads and infrastructure on site Easy Installation worldwide SMA Solar Technology AG 6 Agenda – Product Portfolio 1 Utility-grade PV in the multi-megawatt range 2 Extreme conditions require special solutions 3 Leading quality by advanced tests SMA Solar Technology AG 7 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Grid-connected PV plants with SMA inverters in sunbelt regions Decentralized plants with string inverters Centralized plants with central inverters SMA Solar Technology AG 8 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Challenge: harsh climate conditions > Fact: utility-grade PV plants are being increasingly installed in desert-like regions of the earth’s sunbelt > Opportunities: exploiting new markets, huge areas, establishing utility-grade PV > Challenge: extreme environmental conditions > Desert conditions: hot & dusty areas > High altitudes > 2,000m > Tropical regions & monsoon > Chemically-aggressive environments > Seismic areas SMA Solar Technology AG SMA offers proven system solutions for extreme requirements 9 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Project examples for the sun belt Masdar City (Abu Dhabi) > Installed capacity: 10 MWp > 16 x Sunny Central 560HE > Conditions: > High temperatures (> 50°C) > Sand & dust > Salinity in air Hawaii (USA) > Installed capacity: 0.75 MWp > 3 x Sunny Central 250U > Conditions: > Salinity in air > Seismic area SMA Solar Technology AG 10 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Project examples for the sun belt Greenough River (Australia) > Installed capacity: 10 MWp > 16 x Sunny Central 720 CP > Conditions: > High temperatures up to 50°C > Dusty air Ragusa, Sicily Island (Italy) > Installed capacity: 65 MWp > 80 x Sunny Central 800 CP > Conditions: > Salinity in air > High temperatures up to 50°C SMA Solar Technology AG 11 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Project examples for the sun belt Kagoshima (Japan) > Installed capacity: 70 MWp > 140 x Sunny Central 500 CP-JP > Conditions: > Salinity in air > Seismic area Agua Caliente (USA) > Installed capacity: 290 MWp > 400 x Sunny Central 720 CP > Conditions: > High temperatures up to 50°C > Sand & dust SMA Solar Technology AG 12 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Inverter load profiles Typical load profile in Munich (fixed tilt system) Possible load profile in Riyadh – (dual-axis tracking system) Inverter frequently operates at upper load limit and high temperatures Increased stress level requires ambitious testing SMA Solar Technology AG 13 Agenda – Product Portfolio 1 Utility-grade PV in the multi-megawatt range 2 Extreme conditions require special solutions 3 Leading quality by advanced tests SMA Solar Technology AG 14 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Routine tests > Every single inverter that leaves our factory has been thoroughly tested: > Optical inspection > Wiring test > Protective conductor inspection > High-voltage test > Function test > Endurance test (6h at48°C and nominal load) > At least 1 device is subject to a 48-hour endurance test every week SMA Solar Technology AG Highest reliability included 15 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Test Facilities / Overview of SC Test Center • 1 400 m² test area • 8 test chambers and 7 system test stations • In-house medium-voltage station with three 1.25 MVA transformers • Two 2 500 A busbars for powering the test chambers • Climatic chamber with a 48 m³ test area • Variable DC and AC sources • State-of-the-art measurement technology, e.g. in the areas: voltage, current, power, temperature, humidity and air pressure • Proprietary PV plants for systemtests: • 2,4 MW roof top PV plant (building 58 / Waldau), as of April 2012 • 600 kW roof top PV plant (building 70 / Sanderhäuser-Berg), as of April 2012 SMA Solar Technology AG 9 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Leading quality by ambitious testing > Climate test Î UL 1741 • -25°C (cold start test) to 50°C (16h full load) > Temperature with humidity Î EN 60068-2-78/30 • +30°C, 93% humidity, 4h, no operation, open doors • +30°C, 93% humidity, 72h, operation, closed doors • cycling -35°C … +55°C, 2.25°C/min, 96% humidity, 48h > Arizona dust test Î EN 60068-2-68 • Sand concentration: 1; 3; 5 and 10 g/m³ with particle speed 20 m/s • Sand particle size: < 2µm to 150µm (for comparison typical sand size: 149µm up to 850µm) > Vibration test Î EN 60068-2-64/29 • Transport simulation Class 2M2; 10g > Noise emission Î EN 3744:11 • SC 800CP XT : 80.83 dB(A) @ 1m; 60.82 dB(A) @ 10m > Harmonics test • SC 800CP XT : THD = 1.74% Highest reliability included > Islanding test AID Î IEEE 1547 SMA Solar Technology AG 17 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Seismic qualification test Vibration tests > Tri-axial simultaneous time history tests at a test level of 1.51g, comparable to an earthquake of 8.5 on the Richter scale > Meets the requirements of: > IEC 60068-2-6 > ICC-ES AC156 No damages or changes detected SMA Solar Technology AG 18 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Electromagnetic compatibility > Own absorber chamber 8m x 6m x 12m > Norm-compliant chamber with ferrite pyramid lining, suitable up to 18 GHz > Test options: including electro-magnetic compatibility, electromagnetic emissions The result: normative requirements fulfilled (IEC61000-6-2 (EMC immunity for industrial environments), IEC61000-6-4 (electro-magnetic emissions in industrial environments)) Even more stringent SMA requirements fulfilled Highest reliability included SMA Solar Technology AG 19 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Demanding stress tests ensure reliability under all conditions > Walk-in climate chamber (48m³) in our own development test center > Inverters are tested to the limits of their operational capabilities at temperatures ranging from -40 °C to +65 °C > Single components (e.g. SC20Cont) are proved up to 120°C (Shock –Test) > The chamber can also create relative humidity of between 10% and 95%. > Endurance tests of up to 1,000 hours Quality is tested and not just simulated Highest reliability in extreme climate conditions SMA Solar Technology AG 20 1. Utility-Grade PV | 2. Proven technology | 3. New and upcoming features | 4. Extreme conditions | 5. Advanced tests Sand & dust test > In accordance with IEC 68-2-68 Cat. Lc1 (circulation chamber) > Particle composition similar to the desert in Arizona > Wind speeds up to 20 m/s > Certificate available on request SMA Solar Technology AG No sand or dust in the inverter or the fans 21 Fault Ride Through Test • Fault ride-through test at low-voltage levels: • Transformer power e.g. 700kW • Power of testsystem: 1000 kW • test procedure: interruption-free switching of the transformer secondary Æ voltage drop Æ inverter will react on this event Proven grid management SMA Solar Technology AG 22 Thank you for your attention… Global Technical Consulting & Projects
Similar documents
SMA
> Flexible production output according to market growth SMA Solar Technology AG
More information