GA medTVdigital
Transcription
GA medTVdigital
Operating Instructions Mounting Instructions Service Instructions Camera System medTV digital Examination Lights ML 101 / ML 201 spanisch ML 101 / ML 201 französisch ML 101 / ML 201 italienisch ML 101 / ML 201 Martin medTV digital Operating/Mounting/Service Instructions Table of Contents 1 Safety Instructions ................................................................................4 2 General Information & Instructions......................................................7 2.1 2.2 User’s Inspection ................................................................................................7 Scope of Delivery ................................................................................................7 2.2.1 2.2.2 2.3 2.4 2.5 2.6 2.7 3 PAL System Delivery Options...................................................................................... 7 NTSC System Delivery Options ................................................................................... 9 Complaints ........................................................................................................11 Return of Goods................................................................................................11 Warranty ............................................................................................................11 Hotline................................................................................................................11 Disposal of the Unit ..........................................................................................12 Introduction and Description..............................................................13 3.1 3.2 Intended Use .....................................................................................................13 Design ................................................................................................................13 4 Parts & Spare Parts List......................................................................15 5 Installation and Start-Up .....................................................................18 5.1 5.2 5.3 Start-Up Step by Step .......................................................................................18 Control Unit .......................................................................................................18 Camera...............................................................................................................19 5.3.1 5.3.2 5.4 Mounting Instructions for Spring Arm with 5-Pole or 7-Pole Rotary Connector ..........................................................................................................21 Monitor and Additional Devices.......................................................................22 5.5 5.5.1 5.5.2 5.5.3 5.5.4 5.5.5 5.5.6 6 6.1 6.2 6.3 2 Mounting the Camera ................................................................................................ 19 Electrical Connection ................................................................................................. 20 Important Notes Concerning the Monitor and the Installation of Additional Equipment22 Ceiling-Tube-to-Wall Connection ............................................................................... 22 Control Unit with Monitor............................................................................................ 23 Control Unit with Video Recorder and Monitor ........................................................... 24 Camera System with Video Recorder, Video Printer and Monitor .............................. 25 Camera System with medTFT pro ............................................................................... 26 Operation .............................................................................................27 Button Functions ..............................................................................................27 Positioning the Camera ....................................................................................28 Correcting the Image Position .........................................................................28 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 7 Cleaning and Care ...............................................................................29 7.1 7.2 7.3 7.4 Cleaning the Camera’s Glass Plate .................................................................29 Replacing the Sterilizable Handle....................................................................29 Cleaning, Disinfecting and Sterilization of the Handle ..................................29 Cleaning and Disinfecting the Camera’s Externally Accessible Parts .........30 8 Troubleshooting ..................................................................................31 9 Wiring Diagram ....................................................................................32 10 Interconnection Diagrams ..................................................................33 10.1 10.2 10.3 10.4 10.5 10.6 10.7 10.8 10.9 10.10 Monitor and Camera Power Supply.................................................................33 Camera on Separate Arm / Light-Head Suspension ......................................34 Camera Support on Separate Arm...................................................................35 Camera Tracking/Spring Arms.........................................................................36 ML 501 R / ML 701 R with Camera on Light Head Suspension .....................37 ML 501 E / ML 701 E with Camera on Light Head Suspension......................38 ML 502 Xvario with Camera on Light Head Suspension ..................................39 ML 502 Xe-vario with Camera on Light Head Suspension ................................40 ML 702 HXvario with Camera on Light Head Suspension................................41 ML 702 HXe-vario with Camera on Light Head Suspension ..............................42 11 Technical Data .....................................................................................43 V 1.0 3 Martin medTV digital Operating/Mounting/Service Instructions We appreciate your decision to buy a Martin product. This product carries the CE-mark, which means that it satisfies the essential requirements laid down in the EC Directive relating to medical devices. We are the manufacturer of this product: Gebrüder Martin GmbH & Co. KG Ludwigstaler Straße 132 • Postfach (P.O. box) 60 D-78501 Tuttlingen • Germany Phone: +49 74 61 706-0 • Fax: +49 74 61 706-193 E-mail: [email protected] • Web site: www.martin-med.com. 1 Safety Instructions The Martin medTV digital camera system is a quality product designed and manufactured in accordance with recognized technical rules! The system left the manufacturer’s premises in perfectly safe condition! Our quality regulations comply fully with DIN ISO 9001 provisions. Please observe the following instructions: • Read the instructions! These Operating/Mounting/Service Instructions will help you to avoid safety hazards. Be sure to read them before using the system and the devices connected to it. • Follow the Instructions! • Keep the Instructions at hand! This enables you to check specific points and retrieve required information anytime. • Be sure also to heed any warnings given on the product! • Only persons who have been specially authorized by the manufacturer may service this camera system. • Servicing tasks must be carried out in accordance with the technical regulations in force at the time. • Before servicing the unit, be sure to deenergize all electric supply lines by disconnecting them from the power source to prevent any accidental voltage supply! • Upon completion of servicing tasks carried out by an authorized firm, the responsible service technician is required to issue a certificate containing the following information: 4 • the date when the service/repair work was performed • the nature and scope of the work performed • the firm’s details • the service technician’s signature V 1.0 Martin medTV digital Operating/Mounting/Service Instructions • If a party other than the manufacturer performed the service, all modified, repaired or replaced parts must be additionally marked with the service technician’s ID label. • After completion of installation or servicing tasks, the service technician is required to check all functions of the camera system and the power supply system for proper working order and operational safety. • No liability will be accepted for damage caused by overvoltage. • Be sure that all connecting cables are properly connected to the system as specified in the attached connection diagram, and that all cables and connectors make safe and solid contact. • Be sure to disconnect the unit from the supply before connecting any cables. • Do not twist cables or lay them in too narrow a radius. Specifically, avoid kinks! • To guarantee safety, the cable shields must be reliably and securely connected to the correct, specially marked grounding terminals and connector sockets. • All appliances and connectors must be kept dry! • Be sure to operate this camera system only within the temperature range specified herein. For details, refer to “Technical Data“! • Do not try to take the unit apart! Only authorized service technicians may perform such work! • Prior to cleaning, always switch off all the units belonging to the operating light system. • All of the system’s components must be protected from dropping, shocks and strong vibrations! Note that improper handling or storage can damage the camera and the control unit. • Never place the control unit on unstable trolleys, stands, supports or tables because it could fall off, getting damaged in the process or causing serious injuries. • Ventilation: Do not operate the control unit in an enclosed space where no ventilation is possible (such as built-in cupboards or closed racks). Never stack units directly on top of each other! • Ingress of liquids or entry of objects: Avoid inserting tools or other objects through the unit’s openings because you might touch dangerous voltage points (live components), which might cause fire or an electric shock! Also, do not let any liquid infiltrate into the device! • Maintenance: Do not attempt to service the camera beyond the recommended care and cleaning measures. Any repairs that become necessary must be performed by qualified specialists! This includes the following cases and incidents: • • Liquids or objects have got inside the camera. • The camera no longer functions in accordance with the Operating Instructions. • The unit was dropped or damaged. • The image quality changes/deteriorates markedly. Spare parts: If replacement parts are needed, make sure that the service technician uses only genuine V 1.0 5 Martin medTV digital Operating/Mounting/Service Instructions spare parts as prescribed and supplied by the manufacturer. Note that the use of nonauthorized parts voids the warranty given! • Safety check: Following completion of any service or repair work, make sure the service technician performs a safety check to ensure that the product is in safe working condition. • Transportation and storage: For transportation and for storage periods up to 15 weeks, the following conditions apply: Temperature: –50°C to +50°C Relative humidity: 10–75% Atmospheric pressure: 500 hPa to 1060 hPa Thereafter, the values specified for the following operating conditions apply. Operating conditions: Temperature: 0°C to +50°C Relative humidity: 30–75% Atmospheric pressure: 700 hPa to 1060 hPa Storage: shock-free in closed or roofed rooms. • Regular safety checks: At least every 24 months, the following checks must be performed on this unit by fully qualified and sufficiently trained and experienced persons who, as a result, are able to perform such work competently and independently (i.e. not bound by instructions): • Inspect the camera and its accessories for mechanical damage. • Check all safety-related labels for legibility. • Enter the results of these checks, together with the date, in a medical equipment log. If the device is not functionally and/or operationally safe, it must either be repaired or the operator must be informed of the hazards associated with its use. 6 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 2 General Information & Instructions 2.1 User’s Inspection Please check the camera and its accessories for possible transport damage or defects immediately upon receipt of the goods. 2.2 Scope of Delivery 2.2.1 PAL System Delivery Options 84-830-00 medTV digital on light-head suspension, PAL basic version • Camera suspension for installation on light-head arm, complete with clamping mechanism • Wall-mounting box (with 15-m data and Y/C line) • Case including: • medTV digital camera • medTV digital control unit, basic version • Data line, 5 m • Y/C cable (S-video cable), 5 m • RJ45 LAN cable, 2 m • RS-232 serial interface cable, 2 m • Software CD • Plug-in power supply unit • medTV digital Operating Instructions 84-830-01 medTV digital on light-head suspension, PAL full version Same as basic version 84-830-00, plus • integrated MPEG 2/4 codec and higher plug-in power supply unit • RS-232 serial interface cable, 2 m 84-830-02 medTV digital on separate arm system, PAL basic version • Camera suspension for installation on separate arm, complete with clamping mechanism • Wall-mounting box (with 15-m data and Y/C line) • Case including: • medTV digital camera • medTV digital control unit, basic version • Data line, 5 m V 1.0 7 Martin medTV digital Operating/Mounting/Service Instructions • Y/C cable (S-video cable), 5 m • RJ45 LAN cable, 2 m • RS-232 serial interface cable, 2 m • Software CD • Plug-in power supply unit • medTV digital Operating Instructions 84-830-03 medTV digital on separate arm system, PAL full version Same as basic version 84-830-02, plus • integrated MPEG 2/4 codec and higher plug-in power supply unit • RS-232 serial interface cable, 2 m 84-830-04 medTV digital mounting set for light-head suspension • Camera suspension for installation on light-head arm, complete with clamping mechanism • Wall-mounting box (with 15-m data and Y/C line) 84-830-05 medTV digital mounting set for separate arm system Only available in conjunction with operating light • Camera suspension for installation on separate arm, complete with clamping mechanism • Wall-mounting box (with 15-m data and Y/C line) 84-830-06 medTV digital retrofit set, PAL basic version Retrofit set for camera installation on pre-wired light head suspension or separate arm system. Case including: 8 • medTV digital camera • medTV digital control unit, basic version • Data line, 5 m • Y/C cable (S-video cable), 5 m • RJ45 LAN cable, 2 m • RS-232 serial interface cable, 2 m • Software CD • Plug-in power supply unit • medTV digital Operating Instructions V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 84-830-07 medTV digital retrofit set, PAL full version (for both versions, i.e. camera installation on light-head suspension or separate arm) Same as basic version 84-830-06, plus • integrated MPEG 2/4 codec and higher plug-in power supply unit • RS-232 serial interface cable, 2 m 84-830-08 medTV digital codec retrofit set • MPEG 2/4 codec for later installation in basic-version control unit 84-830-09 medTV digital Y-cable for operating a medTV digital camera installed on a medTV proplus mounting set 2.2.2 NTSC System Delivery Options 84-830-10 medTV digital on light-head suspension, NTSC basic version • Camera suspension for installation on light-head arm, complete with clamping mechanism • Wall-mounting box (with 15-m data and Y/C line) • Case including: • medTV digital camera • medTV digital control unit, basic version • Data line, 5 m • Y/C cable (S-video cable), 5 m • RJ45 LAN cable, 2 m • RS-232 serial interface cable, 2 m • Software CD • Plug-in power supply unit • medTV digital Operating Instructions 84-830-11 medTV digital on light-head suspension, NTSC full version Same as basic version 84-830-10, plus • integrated MPEG 2/4 codec and higher plug-in power supply unit • RS-232 serial interface cable, 2 m V 1.0 9 Martin medTV digital Operating/Mounting/Service Instructions 84-830-12 medTV digital on separate arm system, NTSC basic version • Camera suspension for installation on separate arm, complete with clamping mechanism • Wall-mounting box (with 15-m data and Y/C line) • Case including: • medTV digital camera • medTV digital control unit, basic version • Data line, 5 m • Y/C cable (S-video cable), 5 m • RJ45 LAN cable, 2 m • RS-232 serial interface cable, 2 m • Software CD • Plug-in power supply unit • medTV digital Operating Instructions 84-830-13 medTV digital on separate arm system, NTSC full version Same as basic version 84-830-12, plus • integrated MPEG 2/4 codec and higher plug-in power supply unit • RS-232 serial interface cable, 2 m 84-830-16 medTV digital retrofit set, NTSC basic version Retrofit set for camera installation on pre-wired light head suspension or separate arm system. Case including: • medTV digital camera • medTV digital control unit • Data line, 5 m • Y/C cable (S-video cable), 5 m • RJ45 LAN cable, 2 m • RS-232 serial interface cable, 2 m • Software CD • Plug-in power supply unit • medTV digital Operating Instructions 84-830-17 medTV digital retrofit set, NTSC full version Same as basic version 84-830-16, plus 10 • integrated MPEG 2/4 codec and higher plug-in power supply unit • RS-232 serial interface cable, 2 m V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 2.3 Complaints Claims for damages can only be recognized if either the seller or the carrier is notified immediately of any damage or loss that may have occurred in transit. In such a case, the damage or loss must be established at once and the corresponding report sent to the nearest Martin representative or directly to Gebrüder Martin so that the compensation claims involved can be duly filed with the insurer. 2.4 Return of Goods When returning a product to Gebrüder Martin or a Martin service representative, please use the original packaging as far as possible and include the following documentation: • Name and address of customer/owner • Type and serial numbers • Description of the defect 2.5 Warranty Gebrüder Martin’s Standard Terms of Business shall apply (as revised and updated from time to time). Within the warranty period, we will remedy free of cost – either through our Technical Service or directly in the factory – any defects caused by a manufacturing error or the use of defective material. Important note! The unit may be repaired only by us or by a person or firm expressly authorized by us to carry out such work. If the repair is performed by an authorized person or firm, the repairer is required to issue to the operator of the unit a certificate with details about the nature and scope of the repair work done. This certificate must be dated and signed and must include the firm’s details. In addition, repaired devices or components must be clearly marked with the service technician’s ID label in all cases where a party other than the manufacturer of the product performed the work. 2.6 Hotline Should you have any technical questions or require replacement parts, please contact our hotline. Gebrüder Martin Hotline Technical Service Spare Parts Phone: +49 74 61 706-343 Phone: +49 74 61 706-199 Fax: +49 74 61 706-190 Fax: +49 74 61 706-190 V 1.0 11 Martin medTV digital Operating/Mounting/Service Instructions E-mail: [email protected] Our service representatives are available Monday through Friday from 8 a.m. to 5 p.m. (CET). In case you have any questions concerning maintenance contracts or training courses, please contact our Technical Service Manager under +49 74 61 706-332, or send an e-mail to: [email protected]. 2.7 Disposal of the Unit In designing the unit, we tried to avoid using composite materials wherever possible. This concept ensures that a significant part of the unit can be recycled once it has reached the end of its useful life. This also explains why we offer to take back the unit so it can be appropriately disposed of and recycled. We would also like to point out that the provisions of the electronic waste regulation must be duly observed at the time of disposal. 12 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 3 Introduction and Description 3.1 Intended Use The medTV digital camera system is intended for recording the surgical procedures during an operation. Thus, the video images can be used for patient-specific documentation as well as for training purposes, e.g. in the form of a live operation transmission. 3.2 Design 1 2 The medTV digital camera system consists of the camera and the control unit. The camera can be installed either on the operating light’s own suspension (see Fig. 1) or on a separate arm (Fig. 2). The very high resolution in conjunction with a wide zoom and sensitivity range satisfies the highest demands and enables an excellent image quality. The horizontal resolution, with about 460 TV lines, is so high that the composite color video signal usually used in television engineering is no longer sufficient for transmission. Therefore, the camera features a Y/C output (S-video) that makes this system compatible with conventional video systems as well as S-video recorders and S-video monitors. Needless to say, the system also allows you to connect TFT flat screens, medical screens and commercial monitors. V 1.0 13 Martin medTV digital Operating/Mounting/Service Instructions The camera system offers electronic focus, zoom and shutter control, thus giving the user excellent control of the video image, enabling him to focus precisely, change the image scale as appropriate (e.g. magnify image sections) and adjust the brightness. 3 The camera is controlled via a separate control unit (Fig. 3) installed in the operating room and/or through the supplied software that can be installed on any computer. (The software documentation is contained on the CD-ROM supplied with the product.) Important notes! • The camera is NOT sterilizable! • The objective is not suitable for wet disinfection! 14 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 4 Parts & Spare Parts List Pos. Description/Designation Item Number Units 1 Control cable, 5-m data line with LEMO plug at both ends 08-207-00-11 1 2 Plug-in power supply unit for control unit 08-230-00-03 1 3 Y/C (S-video) connecting cable 08-247-00-01 1 4 RJ45 LAN cable 08-071-00-01 1 5 Software CD 08-230-00-05 1 08-230-00-04 1 08-230-00-50 1 08-218-00-08 1 6 medTV digital control unit 7 RS-232 serial interface cable 8 medTV digital camera 9 Snap-action mechanism for medTV light-head suspension digital camera fitted to cardan joint of 08-074-00-07 1 10 Snap-action mechanism for medTV digital camera installed on separate arm 08-074-00-09 1 11 Exchangeable handle sleeve (ML501/502/701/702/1001) 86-900-00 1 12 Rocker switch, black, round 08-233-00-01 1 13 Wall-mounting connecting box and ceiling-mounted supply-and-suspension digital system complete for medTV (incl. 15-m cable) 08-201-00-02 1 14 Transformer, 65 VA (only for camera on separate arm) (not shown) 86-500-08-04 1 08-060-02-01 1 16 Spring arm, 9–15 kg, RAL 9002, with tracking arm adapter (for digital ML 501 E/R, ML 502 + medTV ) (not shown) 08-060-01-05 1 17 Spring arm, 14 kg, RAL 9002 (for ML701 + camera) 08-060-02-05 1 18 Transformer, 168 VA (monitor + control unit) (not shown) 86-500-15-04 1 19 Video codec (MPEG2/4) 08-248-00-01 1 15 Spring arm, 3.2 kg, RAL 9002 (for medTV (not shown) V 1.0 digital camera on separate arm) 15 Martin medTV digital Operating/Mounting/Service Instructions Camera, control unit and connecting cables in carrying case Basic version 16 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions Camera adapter 10 9 12 11 Wall-mounting box / connection to ceiling tube 13 Control signal socket (connection to control unit) V 1.0 Control cable for connection to ceiling tube 17 Martin medTV digital Operating/Mounting/Service Instructions 5 Installation and Start-Up 5.1 Start-Up Step by Step Please perform the following steps in the given sequence. Details are provided in the following subsections. • Disconnect the system from the supply before connecting the camera and making it ready for operation. • Insert the camera into the snap-action mechanism provided on the light-head suspension or on the separate arm (camera must lock audibly), then insert the elbow plug into the appropriate socket. • Connect the monitor or video recorder to a grounding outlet. • To enable control of the camera’s functions, connect the “Camera” socket of the control unit to the wall-mounting box, using the control cable supplied. • Turn on the camera (separate switch only when camera is mounted on an arm of its own; when installed on the light’s suspension, the camera is switched on together with the light). • Turn on the control unit and the monitor or video recorder. • On first installation or in the case of unnatural colors, adjust color rendition following the instructions given in the monitor’s user manual. 5.2 Control Unit ON/OFF switch 18 Insert control cable here (connects control unit to wall-mounting box) V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 5.3 5.3.1 Camera Mounting the Camera To mount the camera on the light-head suspension or a separate arm, insert the camera pin into the adapter sleeve provided for this purpose until it locks in place (see photo). Adapter sleeve Ball-joint clamping mechanism with arresting lever Camera pin with guide pin Mounting procedure: Insert the camera pin with its guide pin correctly into the adapter sleeve, then push the camera in the direction indicated until it clicks in place audibly. Important: Before letting go of the camera, verify that the camera pin has engaged properly! Elbow plug Dismounting procedure: Hold the camera firmly, then slide the adapter sleeve in the direction shown (on the photo: upwards). Now remove the camera in opposite direction. Attention: Never move the adapter sleeve unless you have firmly taken hold of the camera! V 1.0 19 Martin medTV digital Operating/Mounting/Service Instructions 5.3.2 Electrical Connection Insert the elbow plug into the appropriate socket, then secure it with the knurled nut ON/OFF switch for camera (only with separate arm system) MedTV 20 digital on separate arm system Item number 84-014-01 MedTV digital on light-head suspension Item number 84-013-01 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 5.4 Mounting Instructions for Spring Arm with 5-Pole or 7-Pole Rotary Connector Spring arms with multi-pole rotary connectors (plugs/sockets) feature protective caps (see pos. 1) or protective sleeves (see pos. 2) that need to be removed prior to installation. 1 3 2 Avoid improper handling (tilting/jamming, mechanical impact such as shocks or knocks) because this might damage the connector and lead to malfunction. Never connect plugs to sockets with a different number of poles! Only the matching plug-andsocket connections provided by the manufacturer will guarantee safe and reliable functioning. Check oval shape of socket To ensure perfect contact inside the connector, the contact sockets (see pos. 3) must have an oval shape. Verify that your connectors have the dimensions indicated in the above diagram. If necessary, adjust the connector’s shape manually. Note that a round shape is not permitted as it might cause malfunction. V 1.0 21 Martin medTV digital Operating/Mounting/Service Instructions 5.5 Monitor and Additional Devices 5.5.1 Important Notes Concerning the Monitor and the Installation of Additional Equipment • Monitors connected to the camera must comply with the relevant IEC standards (e.g. IEC 950 for data processing equipment, and IEC 601-1 for medical equipment) and must have been certified accordingly. Besides, all structures should be based on the IEC 601-1-1 system standard. • Everybody who installs additional equipment at the signal input or output configures a medical system and is thus also responsible for the system’s compliance with the IEC 601-1-1 system standard requirements. If in doubt, please consult the Technical Service of your local representative. • The user/operating instructions of all of the units belonging to the camera system must be observed! 5.5.2 Ceiling-Tube-to-Wall Connection Prior to putting the camera system into service, the wall-mounting box must be properly installed in the intended place (usually carried out by an in-house technician). Notes: • Only use the connectors specified herein! The use of other connectors would jeopardize the safety of the system and thus pose hazards to yourself and other persons. • Connecting cables should be laid so that no one steps on them and they are not squashed by objects placed on or against them. Pay particular attention to the cables at the plugs, at the unit sockets and at those points where cables exit from the wall box. 22 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 5.5.3 Control Unit with Monitor In this setup, the monitor is directly connected to the control unit. Most monitors feature a Y/C input jack and thus provide S-video capability. Connect • the control unit (“Camera” socket) to the wall-mounting box • the "Y/C Out" output socket of the control unit to the "Y/C In" input socket of the monitor • the control unit (“LAN” socket) to the local network To ceiling tube / operating light Network RJ45 box Wall-mounting box Monitor Camera Y/C Out LAN Y/C In Control unit V 1.0 23 Martin medTV digital Operating/Mounting/Service Instructions 5.5.4 Control Unit with Video Recorder and Monitor In this setup, a video recorder is directly connected to the control unit. The Y/C signal is then passed on to the monitor via the recorder’s Y/C output. If the video recorder and the monitor feature a Y/C input socket, they are suitable for S-video transmission. Connect • the control unit (“Camera” socket) to the wall-mounting box • the "Y/C Out" output socket of the control unit to the "Y/C In" input socket of the video recorder • the "Y/C Out" output socket of the video recorder to the monitor’s "Y/C In" input socket • the control unit (“LAN” socket) to the local network To ceiling tube / operating light Monitor Wall-mounting box Y/C In Network RJ45 box Y/C Out Y/C In Camera Y/C Out LAN Control unit 24 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 5.5.5 Camera System with Video Recorder, Video Printer and Monitor In this setup, a video recorder is directly connected to the control unit. The recorder’s Y/C output signal is then passed on to the video printer and the monitor. Connect • the control unit (“Camera” socket) to the wall-mounting box • the "Y/C Out" output socket of the control unit to the "Y/C In" input socket of the video recorder • the "Y/C Out" output socket of the video recorder to the video printer’s "Y/C In" input socket • the "Y/C Out" output socket of the video printer to the monitor’s "Y/C In" input socket • the control unit (“LAN” socket) to the local network To ceiling tube / operating light Monitor Wall-mounting box Network RJ45 box Y/C In Y/C Out Camera Y/C In LAN Y/C Out Y/C Out Y/C In Control unit V 1.0 25 Martin medTV digital Operating/Mounting/Service Instructions 5.5.6 Camera System with medTFT pro This setup includes a TFT screen delivered as part of an operating light package, with the video signal available at the wall-mounting box. Alternatively, the monitor can be supplied with an external video signal. For detailed information on the various medTFT pro suspension options, please refer to the Operating Instructions for this product. To ceiling tube / operating light To medTV camera pro pro medTFT flat-panel monitor To medTFT flat-panel monitor digital Wall-mounting boxes Network RJ45 box Y/C Out 26 Camera LAN V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 6 Operation The camera is operated through the control unit and/or the software. The software is documented on the CD supplied with the product. 6.1 Button Functions Upon switching on the control unit, the IRIS, FOCUS and White Balance functions will be immediately available in automatic mode. The ON/OFF switch c and the AUTO buttons f and i will light up. • ON/OFF switch c Use this button to switch the camera on and off. • IRIS (shutter) d e f The IRIS control buttons are used for exposure control. With the AUTO button f, you can switch the automatic mode on and off. The buttons d and e enable you to adjust image brightness manually. When the automatic mode is switched off (button f not illuminated), you can manually adjust the brightness with buttons d and e. Button e also enables you to reduce any fade-over caused by strongly reflecting instrument surfaces. Pressing buttons d and e simultaneously switches over from automatic exposure control to integral measurement (can be preset after switching on the unit) or spot measurement. • FOCUS g h i This function controls image sharpness (focus). Operating the AUTO button i switches the AUTOFOCUS function on and off. When the AUTOFOCUS function is switched off (button i not illuminated), you can adjust the image sharpness by holding down either button g or button h. If you change the zoom setting, it may be necessary to adjust the manual focus setting as well. Pressing the buttons g and h simultaneously switches between freeze mode and live mode. • ZOOM j k The zoom function allows you to change the image scale (object-to-image ratio, or magnification). Button j scales down (demagnifies), button k scales up (magnifies). V 1.0 27 Martin medTV digital Operating/Mounting/Service Instructions Pressing the buttons j and k simultaneously displays the camera menu in the camera image (with the current camera status, e.g. zoom setting, indicated in the form of sliding controls). • 6.2 White Balance l The white balance adjusts the image colors to the color temperature of ambient lighting. To perform the automatic white balance, first place a white surface in front of the camera, then press button l for about 2 seconds until the button’s backlight confirms the action. The white balancing is now completed. Positioning the Camera The camera can be repositioned by adjusting either the light head or the camera itself (when installed on a separate arm), using the respective handle in each case. 6.3 Correcting the Image Position To achieve a correct image position in every camera position, the camera can be rotated in its mounting (retaining ring). Important note: To ensure the greatest possible freedom of movement, no limit stops were used. However, you should avoid multiple camera rotations because this could damage or twist off the cable! 28 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 7 Cleaning and Care 7.1 Cleaning the Camera’s Glass Plate Since a dirty camera glass will affect image quality, you should clean this glass regularly using a mild cleaning solution: • Remove the handle (as described in the following subsection). • Clean the glass with a soft, lint-free cloth. If necessary, moisten it with a mild cleaning solution. Notes: • Never use scouring agents, solvents or benzine for this purpose because these agents would damage the glass or the objective. • All surfaces may be cleaned only with a mild cleaning agent and a soft, lint-free cloth. 7.2 Replacing the Sterilizable Handle Release the handle by pressing down the locking bar Remove the handle in the direction indicated Important: Be sure that the new handle engages audibly. This may require a slight rotation to the left or right after sliding it on. 7.3 Cleaning, Disinfecting and Sterilization of the Handle The exchangeable handle can be processed by machine with the same programs used for your surgical instruments. The handle is thermostable and can be thermally disinfected at 93°C (199°F). Be sure to observe the instructions given by the manufacturer of your automatic washer-disinfector and the manufacturers of the cleaning agents used. We recommend using fully demineralized water for the final rinse to prevent deposits or surface changes such as spots or stains. V 1.0 29 Martin medTV digital Operating/Mounting/Service Instructions 7.4 Cleaning and Disinfecting the Camera’s Externally Accessible Parts All external surfaces of the camera system may be cleaned with neutral, tenside-based cleaners (mild washing-up liquids, neutral cleaning agents). For disinfecting, neutral disinfectants (such as surface disinfectants) based on aldehydes, quaternary ammonium compounds, etc., may be used. To protect the camera as well as the operating light and the tracking and spring arms from ingress of humidity, never spray the parts to be cleaned! Rather, wipe them clean with a cloth moistened with a cleaning solution, and disinfect them in the same manner. 30 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 8 Troubleshooting Our camera systems are built according to strict criteria and on the basis of in-process quality control. We used only the best materials and selected electronic components. Therefore, camera failure is improbable. Should problems occur despite of this, your in-house technician may carry out the following checks: Problem/Symptom Remedies No image Check camera, control unit, monitor (position of ON/OFF switch); check mains plug and insert it if not yet done. Note: When the control unit is switched off, the camera’s video image is switched off as well. Check cable connections, monitor and video equipment. Monitor shows black-and-white image Use color monitor. Adjust monitor color saturation control. Monitor image shows unnatural colors Perform white balance on camera. Adjust monitor color saturation control. Monitor shows interference Eliminate external sources of interference (e.g. camera or camera cable near monitors, power cables or equipment that is not interference-proof; all this could cause HF interference). Monitor image out of focus Adjust image sharpness manually or set camera to AUTO mode (see “Operation” section, item “Focus”). Clean camera glass. Should the problems persist, call your Technical Service. By using a second monitor, it is usually possible to determine whether the problem is rooted in the monitor or the camera. However, further error searching is not possible on the spot. If the trouble cannot be remedied by the above measures, please do not hesitate to contact us. The unit may only be serviced and repaired by the manufacturer or by a service representative expressly authorized by us to perform such work. Please note that non-compliance voids the manufacturer’s warranty. V 1.0 31 Martin medTV digital Operating/Mounting/Service Instructions 9 Wiring Diagram 1 2 3 4 5 6 7 8 9 Camera power supply Monitor power supply digital medTV video system Operating light 1 Operating light 2 pro medTFT monitor External monitor (outside of OR) Video recorder Plug-in power supply unit for control unit 32 10 11 12 13 14 15 16 17 Control unit Network box Y/C (S-video) socket Wall-mounting box Network box LAN (hospital network) Multiple cable S-video cable V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 10 Interconnection Diagrams 10.1 Monitor and Camera Power Supply N L1 B1-B2 GND VAC +VDC +VDC at nom. load Monitor 168 VA X 230 X2-0 8,5 28.5 24–26 25.5 15” or 18” 65 VA X E B-D 0 13.2 24–26 24 Camera on sep. arm Terminals L1 L1 F1 Changeover 7 1 8 Transformer 4 ϑ N +UB 37 F4 43 2 3 8 -UB 38 F5 44 9 N PE 5 L1 B1 B2 N +VAC ϑ GND 6 K1 K2 K = contactor K3 7 10 K1 K2 K3 11 ST1 ST2 ST3 ST4 Monitor F1 2.0 A F4 6.3 A L1 +VDC PE LED green LED red LED indicator on canopy N - GND Connecting socket F5 6.3 A Fuse values at 207–241.5 VAC In case of multi-light setups, L1 and N are jumpered at the terminal strip! V 1.0 33 Martin medTV digital Operating/Mounting/Service Instructions 10.2 Camera on Separate Arm / Light-Head Suspension Operating lights: ML 501 / ML 701 / ML 502 / ML 702 / ML 1001 Fuse values at 207–241.5 VAC Arm suspension ML 501 R/E F1 2.0 A 2.0 A F4 6.3 A F5 6.3 A ML 701 R/E ML 502 X/ML 702 HX ML 1001 3.15 A 4.0 A 3.15 A 6.3 A 8.0/10 A 10.0 A 16 A 6.3 A 8.0/10 A 10.0 A 16 A N L1 B1-B2 GND +VAC +VDC +VDC at nom. load Arm / lights 65 VA X E B-D 0 13.2 24–26 24.0 Arm 168 VA X 230 X2-0 8.5 28.5 24–26 25.5 ML 501 R 4.5 28.5 24–40 30.0 ML 501 E 7.6 28.5 24–26 25.5 ML 701 R 220 VA X 230 X1-0 3.6 28.5 24–40 30.0 ML 701 E 300 VA X 0 C-E 0 18.0 22–25 23.5 ML 502 X 0 20.0 24–27 25.5 ML 702 HX 410 VA X 230 X1-0 3.6 29.5 24–40 31.8 ML 1001 E In case of multi-light setups, L1 and N are jumpered at the terminal strip! Transformer L1 L1 F1 7 1 4 ? N 8 +UB 37 F4 43 2 3 8 -UB 38 F5 44 9 N 5 L1 B1 B2 N +VAC ϑ 6 K1 K2 K3 K = contactor 7 10 K1 PE L1 ST1 ST2 ST3 ST4 MedTV digital DIN socket, rear view RS485B brown RS485A white PE LED green LED red LED indicator on canopy 34 N - GND Connecting socket MedTV digital plug, rear view 2 2 7 +VDC 11 K2 K3 5 B 3 GND 4 8 1 6 Shield green -and-yellow Y C green yellow 4 B 1 6 5 8 3 7 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 10.3 Camera Support on Separate Arm DIN socket, 8-pole Plug, 7-pole 2 RS485A C out Y out RS485B 4 5 6 3 8 1 7 MedTVdigital DIN socket, rear view Grounding V 1.0 35 Martin medTV digital Operating/Mounting/Service Instructions 10.4 Camera Tracking/Spring Arms Tracking arm, 7-pole L1 bl re N - GND gr RS485B 2 4 RS485A 5 8 7 bl re PE 3 Plug, 7-pole Slip ring Connecting plug + VDC Spring arm 1 wh Y ye Socket, 7-pole gr re br or ye bl re or gr wh br gr 6 re br Socket, 7-pole ye br gr ye Color coding, multi-light setup: Light 1: red Light 2: yellow Light 3: blue C digital MedTV DIN socket, rear view 36 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 10.5 ML 501 R / ML 701 R with Camera on Light Head Suspension Plug, 7-pole 16...25 VDC Shield 24V GND RS485A RS485B Y out C out Y out C out 2 4 5 RS485A RS485B 6 3 1 7 8 digital MedTV DIN socket, rear view Grounding DC-DC voltage transformer 1 2 3 4 5 6 G Pin3 H2 H1 M2 M1 Pin2 Pin1 5 6 7 Focusing unit M H1 H2 23 ± 0.3 VDC “ST“ = plug R-electronics Control panel V 1.0 37 Martin medTV digital Operating/Mounting/Service Instructions 10.6 ML 501 E / ML 701 E with Camera on Light Head Suspension Plug, 7-pole 16...25 VDC DC-DC voltage transformer RS485A RS485B Y out C out GND 24V shield Focusing unit 2 4 5 6 3 digital MedTV DIN socket, rear view 1 8 Grounding H2 H1 M M Sub-D/25 7 8 9 1 WM FM 7 11 10 5 6 Pin2 Pin3 Pin1 µC X3 X7 1 X6 1 ROM Brake X2 +BREMS +VIN2 1 -VIN2 -LA2 -LA1 X1 C34 +LA1 +VIN2 1 -VIN1 PE E-electronics Control panel 38 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 10.7 ML 502 Xvario with Camera on Light Head Suspension Plug, 7-pole 16...25 VDC Shield 24V GND RS485A RS485B Y out C out Y out C out 2 4 5 RS485A RS485B 6 1 3 7 8 digital MedTV DIN socket, rear view Focusing unit DC-DC voltage transformer ≈12VDC M Dimmer Ballast G-electronics, “e-vario” +5kV -5kV 1 2 3 4 5 6 GND 190–300 V 300V 7 8 9 10 1 “ST“ = plug Control panel 1 V 1.0 39 Martin medTV digital Operating/Mounting/Service Instructions 10.8 ML 502 Xe-vario with Camera on Light Head Suspension Plug, 7-pole 16...25 VDC Shield 24V GND RS485A RS485B Y out C out Y out C out 2 4 5 RS485A RS485B 6 3 1 7 8 Grounding digital MedTV DIN socket, rear view DC-DC voltage transformer G-electronics, “e-vario” Focusing unit 1 2 3 +5kV 4 5 Ballast 6 -5kV 7 8 9 10 GND 190–300 V 300V 1 ≈12VDC M 0-800R Dimmer 1 Control panel “grün“ = green “gelb” = yellow 40 V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 10.9 ML 702 HXvario with Camera on Light Head Suspension Plug, 7 pole 16...25 VDC Shield 24V GND RS485A RS485B Y out Y out C out C out 2 4 5 RS485A RS485B 6 3 1 7 8 digital MedTV DIN socket, rear view DC-DC voltage transformer Halogen ≈12VDC G-electronics, “e-vario” M Changeover to standby bulb M Dimmer Focusing unit Ballast +5kV -5kV 1 2 3 4 GND 5 6 300V 7 8 9 190–300 V 10 1 “ST“ = plug 1 V 1.0 Control panel 41 Martin medTV digital Operating/Mounting/Service Instructions 10.10 ML 702 HXe-vario with Camera on Light Head Suspension Plug, 7-pole 16...25 VDC Shield 24V GND RS485A RS485B Y out C out Y out C out 2 RS485A RS485B 4 5 6 3 1 7 8 Halogen DC-DC voltage transformer digital MedTV DIN socket, rear panel Focusing unit M Changeover to standby bulb G-electronics, “e-vario” Ballast +5kV -5kV 1 2 3 4 GND 5 6 300V 7 8 190–300 V 9 10 Motor 1670:1 gray/orange Motor 485:1 orange/gray Dimmer 1 ≈12VDC M 0-1000R “ST“ = plug 1 42 Control panel V 1.0 Martin medTV digital Operating/Mounting/Service Instructions 11 Technical Data Martin medTV digital Technical Specifications Image sensor 1/6” Super HAD CCD chip TV standard PAL (optionally NTSC) Pixels 752 (H) x 582 (V), 768 (H) x 494 (V) Horizontal resolution > 460 TV lines Line frequency 15,625 Hz, 15,750 Hz Image frequency 50 Hz, 60 Hz Automatic shutter 1/1–1/10000 s Minimum illumination 3 lux Signal-to-noise ratio (SNR) 49 dB Zoom 300x (25 times optical + 12 times digital) Focal distance, zoom lens 2.4 to 60 mm Aperture F 1.6–2.7 White balance automatic Ambient temperature 0°C to 50°C Control unit signal outputs, analog 2 x S-video (Y/C), 2 x Composite (FBAS) Control unit signal outputs, digital * MPEG 2/4 via RJ45 Video standard MPEG-2 (ISO/IEC 13818) MP@ML MPEG-4 (ISO/IEC 14496) M-JPEG Video data transfer rate MPEG-2: 1 Mbit/s – 8 Mbit/s MPEG-4: 9.6 kbit/s – 4 Mbit/s constant or variable Audio standard MPEG-2: MPEG-1 (ISO/IEC 11172-3) 300 Hz – 10 kHz; MPEG-4: G.711; 300 Hz – 3.4 kHz Audio data transfer rate MPEG-2: 384/256 kbit/s MPEG-4: 64 kbit/s Network protocols RTP, RTCP, UDP, TCP, IP, HTTP, IGMP, ICMP, ARP, DHCP, SNMP Power supply: control unit / camera 100–240 V, 50/60 Hz / 24 V (AC/DC) Power input: control unit / camera Max. 24 W / approx. 6 W Dimensions 131 mm x 88 mm (length x diameter) Camera weight approx. 0.85 kg Control unit dimensions (complete) 260 x 70 x 190 (WxHxD) Control unit weight approx. 1.4 kg Protective conductor (PE) terminal Class of protection Type B Conforms to 93/42/EEC * Full version only V 1.0 43 Gebrüder Martin GmbH & Co. KG Ludwigstaler Straße 132 · D-78532 Tuttlingen Postfach 60 · D-78501 Tuttlingen · Germany Phone: +49 74 61 706-0 Fax: +49 74 61 706-193 [email protected] www.martin-med.com 03.04 · 90-189-52-21 · Printed in Germany Copyright by Gebrüder Martin GmbH & Co. KG Alle Rechte vorbehalten. Technische Änderungen vorbehalten. We reserve the right to make alterations. Cambios técnicos reservados. Sous réserve de modifications techniques. Ci riserviamo il diritto di modifiche tecniche.