ventilation fan catalogue

Transcription

ventilation fan catalogue
VENTILATION FAN
CATALOGUE
Proven, Reliable Bathroom
Ventilation Solutions
Thomas & Betts are proud to be the distributor of the MANROSE
range of ventilation fans.
MANROSE offers an extensive range of extraction fans suitable for bathrooms, en-suites,
laundries and kitchens.
PROVEN: Trusted Locally, Proven Globally.
RELIABLE: Durable Ball Bearing Motors with a 5 Year Warranty.
SOLUTIONS: A Complete Range of Fans, Ducting and Accessories.
Unit D3, 3-29 Birnie Avenue, Lidcombe NSW 2141
Western Australia
South Australia
Unit 2, 22 Hammond Rd Cockburn Central WA 6164
86A Richmond Rd Keswick SA 5035
Victoria
Queensland
2/13-15 Brough St Springvale VIC 3171
26 Turbo Drive Cooparoo QLD 4151
Tasmania
Newcastle
Electrical Agencies 4 Linear Court Moonah TAS 7009
Nick Webb Agencies Unit 5, 21 Babilla Close
Beresfield NSW 2322
National Support Centre
Phone: 1300 666 595
Fax: 1300 666 594
Email: [email protected]
Web: www.manrose.com.au
Manrose continues to lead the way
as the “ventilation solution providers”
Thomas & Betts are proud to be the distributor of the MANROSE range of
ventilation fans.
Thomas and Betts have been supplying the electrical wholesale market for over 35 years and
credit their success to outstanding delivery and customer service capabilities and are proud of
their strong, long-standing partnerships. They represent the highest quality and most innovative
products available.
The MANROSE brand is known for proven, reliable solutions with an evolving product range to
meet the demands of the market. Thomas & Betts and MANROSE have a strong relationship,
which has seen ventilation products developed specifically for the Australian market with features
demanded by the customer. This has led to all Manrose products being upgraded with ball
bearing motors and a 5 year warranty.
Within the Manrose range you can choose from a Classic model which offers trusted performance
or a Pro-Series model with higher specifications, installation advantages and features to the
contractor, as well as sought after aesthetics demanded by the consumer. A recent addition to
the range is Vent-Axia Lo-Carbon range that offer ventilation fans with up to 70% energy savings.
The Manrose product development team is consistently developing high quality products
with features demanded by the market. Our policy of ongoing investment in product
development has been a key force in driving the company to the forefront of the ventilation
market. Manrose has an extraction fan for every application. Continual development and
innovation ensures that future market demands are not only met but exceeded!
Lo-Carbon
PUB0385 Iss03 04/13
contents
Ventilation Selection/Regulations
3-9
Selection Chart
10
Ventilation Fans
12-63
Wall/Ceiling Fans
12-21
Thru Wall Fan Kits
22-25
Window Mounted Fans
26-29
Heat/Fan/Light Kits
30-31
In-Line Fan Kits
32-53
Wall Mounted Fans
54-55
Thru-Roof Mounted Fans
56-57
Hand Dryers
58-59
Specialised Fans
60-61
Fan Accessories
62-63
Duct and Fittings
64-79
Duct Standards
Ducting Installation & Usage
64
65-71
Aluduct/Comflex Flexible Ducting
72
Unilok73
Ceiling Diffuser
84-86
Designer Ceiling Diffuser
84
Flat Ceiling Diffuser 84
Ceiling Diffuser
85
Eggcrate Round Diffuser
85
Ceiling Diffuser 86
Cowls/Plate Grilles
87-94
Designer Weatherproof Cowls
87
Weatherproof Cowls
87
Designer Weatherproof Dome
88
Wall/Ceiling Plate Grilles
89
Wall/Ceiling Plate Grilles
89
Door Grille
89
Duct Kits
90-93
Roof Cowls
90-91
Rangehood Ducting Kits
92
Dryer Ducting Kit 93
Pro Series Extension Kit
93
PVC74
Accessories94
Semiduct Semi Rigid Heat Trans Low Profile Ducting
74
75-78
In-Line 78
Branch Take Off 79
Alpha-Numeric Index
Vent-Axia Lo Carbon Range
95-97
98-100
101-104
Reducers79
Duct Joiners/Spigots
79
Wall/Ceiling Grilles
80-83
Designer Wall Grilles
81
Wall Grilles
81
Wall/Ceiling Grilles 82
Designer Wall/Ceiling Grilles
83
Wall/Ceiling Grilles
83
Technical Information
Product category index
Technical information such as dimensions and size
charts can be found beneath or on the page following
the product page.
The product category index is an alphanumeric listing of
general product groups in the Thomas & Betts portfolio, this
can be found on page 98.
2
VENTILATION SELECTION
Why you need Ventilation?
• New building materials and construction methods are effectively resulting in “waterproof” buildings.
They trap moisture inside just as effectively as they keep moisture out.
• Open doors and windows provide air circulation and ventilation but security considerations mean that we are increasingly less likely to use this option. As a result houses tend to remain closed up more often.
• Poor ventilation results in a buildup of moisture generated by cooking/bathing/showering/clothes washing-
drying/LPG gas heating...even breathing!
• Stale air can be caused by cooking smells, odours remaining in the bathroom, a general lack of ventilation around the house as well as a damp atmosphere.
Problems Caused by Poor Ventilation
• All these problems cause an avoidable level of discomfort as well as the risk of respiratory illness and general poor health.
• Problems also occur when steam from the kitchen or bathroom finds cooler surfaces around the house
on which to condense. Warm, moisture-laden air condenses on cold surfaces such as glass, cold ceilings and cold wet-wall linings. This is the moisture that you can see.
• Moisture you cannot see is still present in the atmosphere and will be absorbed into fabrics, wall linings, bedding, etc. Attempts to conserve heat by sealing windows and therefore reducing natural ventilation
makes this problem even worse.
• Condensation can cause considerable problems from peeling wallpaper and mould growth to severe long term structural damage to building materials.
Moisture Generators:
BATHROOM
CONDENSATION
SHOWERING
GAS HEATING
KITCHEN
TOILET
LAUNDRY
BREATHING
WATERING PLANTS
Stale air out
Correct Ventilation
Ventilate Outside
= Healthy Home
Incorrect Ventilation
Trapped moist air Inside
the home = Unhealthy
In dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly into
the roof space is not permitted under the Building Code.
Thomas and Betts | www.manrose.com.au | [email protected]
3
VENTILATION SELECTION
Your Ventilation Solutions
Damp air out
It is best to remove moisture
from where it is generated
to outside the house before
it has a chance to spread to
other parts of the house.
Fresh air in
It is best to remove moisture from where it is generated to outside the house before it has a chance to spread to other
parts of the house. Use ducted fans, through-wall fans or window fans at all times.
DO NOT use ceiling fans which discharge into the ceiling cavity, this only moves the problem.
Moisture will permeate insulation and ceiling linings causing further problems. In particular with bathrooms think in terms
of “room-conditioning”. Warm, moist air is immediately attracted to cold surfaces, where it condenses into water droplets.
Cold surfaces include glass, mirrors, tiles, wet-wall linings, cold un-insulated ceiling linings, etc. You cannot remove
all of this air at a rate fast enough to stop this happening and if you could, you would be standing in a wind tunnel.
Use of a bathroom heater to warm the room prior to use greatly assists in reducing condensation.
Fan Placement
Careful location of an extraction fan will ensure maximum air-flow through the room. Air extracted from a bathroom, for example,
can be replaced with dry air drawn from an adjacent bedroom or hallway, in turn, drawn from an open window or door.
This ensures that fresh air is being drawn into the entire house at regular periods. Switching the fan on before starting
showering or cooking sets up effective air-flows before condensation problems occur. Closing doors to adjacent living
areas assists in stopping the transfer of moisture to those areas but ensure that sufficient air can enter under the door
to replace extracted air.
Use a door vent if necessary.
For a fan to remove air effectively, the same amount of air being extracted must be able to enter the room. E.g. air in =
air out. An air-tight room will mean no air movement. If the room is tightly sealed (e.g. a tight-fitting door, with no gap at
the bottom), you may need to fit a through-door grille to allow replacement air into the room.
Poor Circulation
4
Medium Circulation
Best Circulation
VENTILATION SELECTION
Fan Regulations
What the law states
Australian Building Code Paragraph 3.8.5.0 states:
Performance requirement P2.4.5 is satisfied for mechanical ventilation system if it is installed in accordance with AS
1668.2. “Mechanical ventilation for acceptable indoor air quality”, except that any contaminated air from a sanitary
compartment or bathroom must:
a.
Exhaust directly to outside the building by way of ducts; or
b.
Exhaust into the roof space provided:
i.
It is adequately ventilated by open eaves, and/or roof vents; or
ii.
The roof is clad in roofing tiles without sarking or similar materials, which would prevent venting through gaps between tiles.
As detailed above, in dwellings with a metal roof, or where the roof is lined with sarking, ventilating directly in to the roof
space is not permitted by building codes unless the roof space is adequately ventilated by open eaves or roof vents.
The Manrose range offers many ducted solutions to exhaust to the outside through wall, roof or eaves to comply with the
latest building code. Natural Ventilation for the above is acceptable as long as opening windows in each room have an area
of 5% or more of the floor area of the room.
AS1668 (summarised):
“...Buildings shall have a means of collecting or otherwise removing: cooking fumes and odours; steam
from laundering, utensil washing, bathing and showering; odours from sanitary and waste storage spaces;
poisonous or flammable fumes and gases...”
BCA Compliance to AS/NZ 1530 Part 3
Requirements are:
Internal Surface: Spread of flame not >0
External Surface: Spread of flame not >7
Smoke Developed not >3
Smoke developed not >5
AS/NZS 1530 Part 3
This is the Australian standard 1530, method for fire tests on building materials components and structures.
“Simultaneous determination of ignitability, flame propagation, heat release and smoke release”
Bathrooms
Kitchens
The regulations require a fan capable
of a minimum extraction capacity of
25 litres per second when installed.
The regulations require a fan capable
of a minimum extraction capacity of
50 litres per second when installed.
Toilets
Laundries
The regulations require a fan capable
of a minimum extraction capacity of
25 litres per second when installed.
The regulations require a fan capable
of a minimum extraction capacity of
20 litres per second when installed.
Thomas and Betts | www.manrose.com.au | [email protected]
5
VENTILATION SELECTION
Calculating Fan Performance
Litres/Second (l/s)
Milk 1 Litre
Working out the right fan for
the job
• Calculate the room volume in metres (l x W x H).
Cubic Metres/Hour
(m³/hr)
1m
• Multiply the room volume by the recommended air changes per hour for that room. Always use the higher limit.
1m
• The result is the total performance required
in cubic metres per hour.
1m
To convert from one to other
types of measurement:
If you know Litres/Second (l/s):
l/s x 3.6 = m3/hr (e.g. 25 l/s x 3.6 = 90m³/hr).
If you know Cubic Metres/Hour (m³/hr):
m3/hr ÷ 3.6 = l/s (e.g. 200m³/hr ÷ 3.6 = 55.55 l/s).
Note: 1m3 = 1000 Litres ACH
AIR CHANGES PER HOUR (ACH)
The number of times the total room volume of air is changed
each hour. Refer to the table below for the recommended
Air Changes per hour based on the room type.
Select a fan with a higher performance than
this figure.
For Example:
What is the best fan for a bathroom that is 2.8m long by
2.8m wide with a ceiling height of 2.4m?
• Calculate the volume of the bathroom:
2.8 x 2.8 x 2.4 = 18.8m3.
• 11-15 air changes per hour are recommended for a bathroom. Multiply the room volume by 15: 18.8m3 x 15 = 282m3/hr.
• The fan to choose for this bathroom would be
a fan that performs at greater than 282m3/hr.
• A fan that has a performance level of 313m3/hr
or higher (e.g. XP150, or SF150) would do this job.
Application Description
Air Changes Per Hour
Bathrooms
11 - 15
Kitchens - (domestic)
15 - 20
Laundries - (no drier)
6 - 10
Laundries - (with drier)
10 - 30
m³/hr
l/s
m³/hr ÷ 3.6 = l/s
Toilets
6 - 10
cfm
m³/hr
cfm x 1.69 =m³/hr
Bedroom
2-5
cfm
l/s
cfm x 0.47 = l/s
Offices
6 - 10
Cafés
10 - 12
Quick Cross-Reference
Calculations:
Known
To Find
Action
l/s
m³/hr
l/s x 3.6 =m³/hr
Canteens
8 - 12
350
Garages
6-8
300
Kitchens - (commercial)
20 - 30
250
Restaurants
8 - 12
200
Factories
8 - 10
150
Stores & Warehouses
3-6
Libraries
Classroom
6
3-5
5-7
240
110
400
220
100
200
90
180
80
160
70
140
60
120
50
80
30
100
50
0
100
40
m3/hr
60
20
40
10
20
l/s
cfm
m³/hr to l/s to cfm
Comparison Chart
VENTILATION SELECTION
What Affects Performance?
Simple facts:
Smaller duct = greater resistance to airflow.
More bends = greater resistance to airflow.
Longer duct runs = increasingly reduced airflow.
01
Wrinkled ducting causes turbulence and
reduces airflow:
WRINKLED DUCT
AIRFLOW
Compare Centrifugal Against
Axial Fan Performance:
SF100 (axial) vs an SF200 (centrifugal) fan.
The starting point is the free air performance of 23 l/s
for the axial and 31 l/s for the centrifugal. As duct
is added to each of these fans, this increases the
pressure (Pa) and decreases volume of air moved.
From the below example you can see that at 20Pa
of pressure the 100mm axial fan airflow has stopped
whereas the 100mm centrifugal fan is still moving 29 l/s!
SF100 & SF200 PERFORMANCE GRAPH*
02
Smoother, extended ducting allows smooth,
increased airflow:
SMOOTH DUCT
AIRFLOW
SF200
SF100
Manrose ALUDUCT flexible ducting retains
its stretched-out shape (for smooth airflow)
far better than most competitive products.
*Graphs are a visual
representation only.
Many competitive ducts tend to shrink back
on themselves, wrinkling the duct fabric.
ID150 (axial) vs a MAN150 (centrifugal) fan.
The starting point is the free air performance of 89
l/s for the axial and 115 l/s for the centrifugal.
Fan type
Centrifugal: Pressure developing fans which achieve
good flow against the resistance created in a ducted
system. Particularly useful in venting areas like internal
bathrooms/laundries, multi-room extraction systems,
heat-transfer systems, etc.
Mixed Flow: Powerful in-duct mounted fans, designed
for applications that require high air flows, with low
relative noise. Can handle more pressure than an axial
fan, although not as powerful as a centrifugal fan.
Axial: Suitable for wall, window and roof applications
where they can extract directly to the outside.
Short duct runs are an option but the length of duct
should be limited.
e.g.
100mm dia : 2-3m length
125mm dia : 3-4m length
150mm dia : 4-5m length
As duct is added to each of these fans, this increases
the pressure (Pa) and decreases the volume of air
moved. From the below example you can see that
at 120 Pa of pressure the 150mm axial fan airflow
has stopped whereas the 150mm centrifugal fan is still
moving 102 l/s!
0
72 144 216 288 360 432 504
30
MAN150
25
300
250
20
200
15
150
ID150
10
100
50
5
0
20 40
60 80 100 120 140
*Graphs are a visual
representation only.
Thomas and Betts | www.manrose.com.au | [email protected]
7
Wet Areas & Recommended Fan Types
When considering where in the room to place an extractor fan,
you must consider the wet areas.
Zone 1: This is the zone directly within the shower or bath up
to 2.25 metres above the floor and 150mm around the bath/
shower cubicle. A SELV fan or an in-line fan kit will be required
in this zone.
Zone 1:
Requires a SELV Fan or an
In-Line fan kit
For example if a fan is mounted directly over the bath or
shower it must be a low voltage fan (SELV).
Zone 2:
Any fan model can be used
Zone 3:
Any fan model can be used
Zone 2: This zone is 0.6 metres horizontally outside of zone 1
and up to 2.25 metres above the floor.
Zone 3: The outer layer is zone 3, which is 2.4 metres horizontally
outside of zone 2 and 2.25 metres above the floor.
Locate your Ventilation Fan
Wet area zone guide
Outside Zones
Outside Zones
Zone 1: Requires a Low Voltage Fan.
Zone 2: Any fan model can be used.
Zone 3: Any fan models can be used.
How To Order
Select the model that exhausts the closest to your requirements.
If the performance required falls between two fans, it is recommended
you select the one handling the most air.
8
VENTILATION SELECTION
Fan Application Examples
Location of your ventilation fan will depend on the physical constraints of your room. The wet area zone guide (shown
on the previous page) will help you decide the most suitable physical installation to meet your requirements. Within the
above mounting options there are various other features available, such as:
• TIMER (maintain fan run-on after the room is vacated).
• PULLCORD (Switch at fan, instead of wall switch control).
• AUTO-SHUTTER (electrically operated shutters inside the
fan - closed when the fan is not running to stop draughts).
• PIR SENSOR (provide automatic motion-sensor control of fans).
1. Ceiling Mounted Fan
4. In-Line Mounted Fan Kit
Designed for low-pitch roofs or between floors,
where there is no ceiling access. Also available
with heat lamps & lighting.
Most common bathroom installation, the fan
is mounted in the ceiling space with the grille
directly above the source of the steam.
Generally this type of installation is quieter as
the fan is not directly in the room.
01
04
Page Reference 12-21
2. Thru Wall Fan Kit
Used where the bathroom is on an external wall,
or there is no ceiling space for an in-line fan.
Page Reference 32-53
5. Thru Roof Kit
02
Used where there is limited access to the roof
space, or where there is no soffit available.
Thru Roof Kits can be used with any extraction
fan, or use a Thru Roof Fan Kit with the fan
mounted within the cowl.
Page Reference 22-25
05
3. Window Mounted Fan
Used in situations where an existing window fan
is being replaced, or where there is no available
external wall space and no ceiling space access.
03
Page Reference 56-57
Page Reference 54-55
Thomas and Betts | www.manrose.com.au | [email protected]
9
SELECTION CHART
Selecting the right fan is Easy
Wall/Ceiling Fans
ROOM TYPE
Toilets
Laundries - No Dryer
Basement
Offices
These rooms
require between
6 and 10 ACH
Bathrooms
Showers
Ensuites
These rooms
require between
11 and 15 ACH
Kitchens
Laundries - With Dryer
These rooms
require between
15 and 20 ACH
Thru Wall Fan Kits
Room Size
(m3)
VA Lo-Carbon
Pro-Series
Classic
Pro-Series
Classic
1-5m3
LCS150
XFLP125
XF125
XPLP125
XP125
6-10m3
LCS150
XFLP125
XF125
XPLP125
XP125
11-15m3
LCS150
XFLP150
XF150
XPLP150
XP150
1-10m3
LCS150
XFLP150
XF150
XPLP150
XP150
11-15m3
LCS150
XFLP150
XF150
XPLP150
XP150
16-20m3
-
XFLP150
XF150
XPLP150
XP150
21-30m3
-
1-5m3
LCS150
XFLP150
XF150
XPLP150
XP150
6-10m3
-
XFLP150
XF150
XPLP150
XP150
11-20m3
-
XFS230
XPS230
XF230
XPS230
3 Step Selection Guide
01
01
01
02
02
02
03
03
Select your required application, e.g. Bathrooms
(11-15 air changes per hour).
Calculate the volume of the room in cubic metres
(m3) by multiplying the length x width x height E.g.
2.3m x 2.2m x 2.4m = 12.14m3
(Select a room volume 11-15m3).
10
HEAT/FAN/
LIGHT UNITS
IN-LINE FAN KITS
EXTRACT-A-LITE KITS
WINDOW
FANS
THRU ROOF
FAN KITS
Pro-Series
Pro-Series
Classic
Pro-Series
Classic
Pro-Series
Classic
Heat ‘n Vent 2
SFLP125
SF125
ELLP125
EL100
WF150
HYPER
Heat ‘n Vent 2
SFLP125
SF125
ELLP125
EL125
WF150
HYPER
Heat ‘n Vent 4
SFLP150
SF150
ELLP150
EL150
WF150
HYPER
Heat ‘n Vent 2
SFLP150
SF150
ELLP125
EL150
WF150
HYPER
Heat ‘n Vent 4
SFLP150
SF150
ELLP150
EL150
WF150
HYPER
SFLP150
SF150
ELLP150
EL150
WF150
ULTRA
WF230
ULTRA
MFLP150
SFLP150
SF150
ELLP125
EL150
WF150
HYPER
SFLP150
SF150
ELLP150
EL150
WF150
HYPER
WF230
ULTRA
MFLP150
03
Follow the 12m3 row across and select one of the fan kits available
based on your mounting requirements (see top headings and photos).
E.g. If you require a Thru Wall Kit then you can choose any of the XP150
or XPLP150 kits.
Note: All selections are based on installed fan performance and maximum
air change rates (figures in brackets show actual air changes stated if
less than maximum).
Thomas and Betts | www.manrose.com.au | [email protected]
11
Manrose PRO-SERIES wall/ceiling mounted fans
xflp low profile models
Square Models
Duct Size
Model No.
Switching Method
Performance
3
Order Code
125mm
XFLP125SS
Standard
36 l/s, 130m /hr
FAN0589
125mm
XFLP125ST
Timer
36 l/s, 130m3/hr
FAN0590
150mm
XFLP150SS
150mm
XFLP150ST
Standard
3
FAN0594
3
FAN0595
87 l/s, 313m /hr
Timer
87 l/s, 313m /hr
Circular Models
Duct Size
Model No.
Switching Method
Performance
Order Code
125mm
XFLP125CS
Standard
36 l/s, 130m3/hr
FAN0604
125mm
XFLP150CS
150mm
150mm
Standard
FAN0609
3
FAN0610
87 l/s, 313m /hr
87 l/s, 313m /hr
Timer
XFLP150CT
FAN0605
3
36 l/s, 130m /hr
Timer
XFLP125CT
3
Safety extra low voltage (selv) models
Duct Size
Model No.
125mm
XFLP125SLV
125mm
150mm
Performance
Order Code
SELV 12V
36 l/s, 130m3/hr
FAN0591
XFLP125CLV
SELV 12V
36 l/s, 130m3/hr
FAN0606
XFLP150SLV
SELV 12V
87 l/s, 313m3/hr
FAN0596
XFLP150CLV
150mm
Switching Method
SELV 12V
3
87 l/s, 313m /hr
FAN0611
Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a
transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).
Duct
Size
Description:
Square
Order Code
125mm
Satin Silver
Fascia
FAN2069
125mm
Satin Silver
Fascia
FAN2068
125mm
Chrome Fascia
FAN0757
125mm
Chrome Fascia
FAN0755
150mm
Satin Silver
Fascia
FAN2070
150mm
Satin Silver
Fascia
FAN2071
150mm
Chrome Fascia
FAN0613
150mm
Chrome Fascia
FAN0598
• Unique low profile design enables these fans to be installed unobtrusively into any wall or ceiling.
• These axial fans have been upgraded with ball bearing motors to prolong the life of the motor.
• Supported by a 5 year warranty.
EA
Order
Code
LB
Description:
Circular
BAL
Duct Size
R
ACCESSORIES
Switching Options
1. Standard Model - operates from remote switch (not supplied).
3. SELV Model - Suitable for installation in damp areas, zones 1, 2 and 3.
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.
NOTE: All fan flow rates quoted are free air delivery.
12
GM
OT O R
5
IN
YEAR WARRANTY
TECHNICAL DATA
General information
Models
Circular Cut-Out Size
XFLP125S
140mm - Using gib fixing clips supplied/included
XFLP125C
140mm - Using gib fixing clips supplied/included
XFLP150S
173mm - Using gib fixing clips supplied/included
XFLP150C
173mm - Using gib fixing clips supplied/included
DIMENSION INFORMATION (mm)
Models
A
B
C
D
XFLP125S
161
122
10
118
XFLP125C
165
122
10
118
XFLP150S
191
122
10
150
XFLP150C
198
122
10
150
Dimensions - XFLP
A
A
A
C
D
B
TECHNICAL SPECIFICATION
Models
XFLP125
XFLP150
Power
220 - 240V (SELV models 12V)
220 - 240V (SELV models 12V)
Fan Performance
36 l/s, 130m /hr
87 l/s, 313m3/hr
Fan Wattage
20W
25W
Maximum Pressure
35 Pa
60 Pa
Fan Speed
2000 RPM
2400 RPM
Sound Level
41 dB(A)
40 dB(A)
Max. Operating Temp
50°C
50°C
IP Rating
IPX4
IPX4
Performance - XFLP125
3
Performance - XFLP150
Thomas and Betts | www.manrose.com.au | [email protected]
13
Manrose CLASSIC WALL/CEILING MOUNTED FANS
XF Models
STANDARD Models
Duct Size
100mm
Model No.
XF100S
Switching Method
Standard
Performance
Order Code
3
FAN0046
3
23 l/s, 85m /hr
100mm
XF100P
Pull Cord
23 l/s, 85m /hr
FAN0047
100mm
XF100T
Timer
23 l/s, 85m3/hr
FAN0048
3
125mm
XF125S
Standard
36 l/s, 130m /hr
FAN0072
125mm
XF125P
Pull Cord
36 l/s, 130m3/hr
FAN0074
3
125mm
XF125T
Timer
36 l/s, 130m /hr
FAN0075
150mm
XF150S
Standard
87 l/s, 313m3/hr
FAN0120
3
150mm
XF150P
Pull Cord
87 l/s, 313m /hr
FAN0126
150mm
XF150T
Timer
87 l/s, 313m3/hr
FAN0127
150mm
XF150PIR
PIR Control
3
87 l/s, 313m /hr
Standard Model
FAN0124
AUTO SHUTTER Models
Duct Size
Model No.
Switching Method
Performance
Order Code
150mm
XF150A
Standard
87 l/s, 313m3/hr
FAN0121
150mm
XF150AP
Pull Cord
87 l/s, 313m3/hr
FAN0122
150mm
XF150AT
Timer
87 l/s, 313m3/hr
FAN0123
Safety extra low voltage (selv) models
Auto Shutter Model
Order Code
100mm
XF100LV
SELV 12V
23 l/s, 85m3/hr
FAN0044
3
125mm
XF125LV
SELV 12V
36 l/s, 130m /hr
FAN0071
150mm
XF150LV
SELV 12V
87 l/s, 313m3/hr
FAN0119
Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a
transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).
Safety Model (SELV)
• Designed for wall or ceiling mounting, these models are efficient and easy to install.
• These axial fans have been upgraded with ball bearing motors to prolong the life of the motor.
• Supported by a 5 year warranty.
R
Performance
EA
Switching Method
LB
Model No.
BAL
Duct Size
Switching Options
1. Standard Model - operates from remote switch (not supplied).
2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes.
3. Pull Cord Model - Integral pull cord switch on fan.
4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts.
5. PIR Model - Motion sensor incorporated in fan.
6. SELV Model - Suitable for installation in damp areas, zones 1, 2 and 3.
NOTE: All fan flow rates quoted are free air delivery
14
GM
OT O R
5
IN
YEAR WARRANTY
TECHNICAL DATA
GENERAL INFORMATION
Models
Circular Cut-Out Size
XF100
112mm
XF125
135mm
XF150
160mm
Please note: Fan cut out size is a nominal diameter.
DIMENSION INFORMATION (mm)
Dimensions - XF
Models
A
B
C
D
E
XF100
155
98
74
27
155
XF125
168
118
74
27
168
XF150
200
148
74
27
200
XF150PIR
200
148
90
55
200
XF150A/AP
200
148
90
55
200
C
A
B
D
E
TECHNICAL SPECIFICATION
Models
XF100
XF125
Power
220 - 240V (LV models 12V)
220 - 240V (LV models 12V)
3
220 - 240V (LV models 12V)
Fan Performance
23/s, 85m /hr
36 l/s, 130m /hr
87 l/s, 313m3/hr
Fan Wattage
20W
20W
25W
Maximum Pressure
20 Pa
35 Pa
60 Pa
Fan Speed
2400 RPM
2000 RPM
2400 RPM
Sound Level
41 dB(A)
41 dB(A)
40 dB(A)
Max. Operating Temp
50°C
50°C
50°C
IP Rating
IPX4
IPX4
IPX4
Performance - XF100
3
XF150
Performance - XF125
Performance - XF150
Thomas and Betts | www.manrose.com.au | [email protected]
15
Manrose CLASSIC WALL/CEILING FANS
XFS COMMERCIAL Models
Duct Size Model No. Switching Method
Performance
230mm
152 l/s, 550m3/hr
300mm
300mm
XFS230S
XFS300S
XFS300S
Standard
Standard
Standard
Order Code
FAN0374
3
FAN2040
3
FAN2040
306 l/s, 1100m /hr
306 l/s, 1100m /hr
AUTO SHUTTER Models
Commercial Models
Duct Size
Model No.
Switching Method
Performance
Order Code
3
230mm
XFS230A
Standard
152 l/s, 550m /hr
FAN0346
300mm
XFS300A
Standard
306 l/s, 1100m3/hr
FAN2041
Auto Shutter Models
Manrose Classic THRU WALL FAN KITS
XPS COMMERCIAL Models
Duct Size Model No.
Switching Method
Performance
230mm
Standard
152 l/s, 550m3/hr
300mm
XPS230S
XPS300S
Standard
Order Code
FAN0455
3
306 l/s, 1100m /hr
FAN2042
AUTO SHUTTER Models
Commercial Models
Duct Size
Model No.
Switching Method Performance
230mm
XPS230A
Standard
300mm
XPS300A
Standard
Order Code
152 l/s, 550m3/hr
3
306 l/s, 1100m /hr
FAN0348
FAN2043
BAL
LB
EA
R
Auto Shutter Models
GM
OT O R
5
IN
YEAR WARRANTY
16
TECHNICAL DATA
GENERAL INFORMATION
Models
Fan Cut-Out Size
Exterior Grille
Duct Type
Duct Length
XFS230
265mm
-
-
-
XFS300
310mm
-
-
-
XPS230
265mm
White Fixed Grille
Aluminium Semi-Rigid
375mm
XPS300
310mm
White Fixed Grille
Aluminium Semi-Rigid
375mm
Please note: Fan cut out size is a nominal diameter.
DIMENSION INFORMATION (mm)
Models
A
B
C
D
E
F
G
H
I
XFS230
286
230
141
75
66
-
-
-
-
XFS300
362
300
156
81
75
-
-
-
-
XPS230
286
230
141
75
286
250
375
248
30
XPS300
362
300
156
81
350
230
375
298
50
Dimensions - XF230/300
Dimensions - XPS230/300
C
C
E
A
B
E
A
G
I
H
F
D
B
A
D
TECHNICAL SPECIFICATION
Models
XFS230
XFS300
XPS230
XPS300
Power
220 - 240V
220 - 240V
220 - 240V
220 - 240V
Fan Performance
152 l/s, 550m³/hr
306 l/s, 1100m³/hr
152 l/s, 550m³/hr
306 l/s, 1100m³/hr
Fan Wattage
45W
82W
45W
82W
Maximum Pressure
50 Pa
60 Pa
50 Pa
60 Pa
Fan Speed
1250 RPM
1300 RPM
1250 RPM
1300 RPM
Sound Level
50 dB(A)
60 dB(A)
50 dB(A)
60 dB(A)
Max. Operating Temp
50°C
50°C
50°C
50°C
IP Rating
IPX4
IPX4
IPX4
IPX4
Performance
- XFS230
Performance
- XFS300
Thomas and Betts | www.manrose.com.au | [email protected]
17
WHISPERVENT CEILING FANS
CENTRIFUGAL CEILING FAN MODELS
Duct Size
Model No.
Colour
Performance
Order Code
100mm
WVC100W
White
63 l/s, 225m3/hr
FAN0884
100mm
WVC100S
Stainless
63 l/s, 225m3/hr
FAN0885
150mm
WVC150S
White
100 l/s, 360m3/hr
FAN2465
•
•
•
•
Designed for apartments where space is limited, these ceiling mounted
fans can be installed in confined spaces.
The centrifugal fan design assists‘whisper quiet’ operation.
Reliable long lasting ball bearinng motor
Supported by a 3 year warranty.
NEW
Simx Whispervent 150 - White
Simx Whispervent 100 - Silver
3
YEAR WARRANTY
Switching Options
1. Standard Model - operates from remote switch (not supplied).
18
TECHNICAL DATA
DIMENSION INFORMATION (mm)
Models
A
B
C
D
WhisperVent 100
240
290
172
98
WhisperVent 150
310
330
370
37
Dimensions - WhisperVent 100
E
F
184
30
Dimensions - WhisperVent 150
D
A
B
C
C
C
A
B
E
D
TECHNICAL SPECIFICATION
Models
WhisperVent 100
WhisperVent 150
Power
220 - 240V
220 - 240V
3
Fan Performance
63 l/s, 225m /hr
100 l/s, 360m3/hr
Fan Wattage
30W
42W
Maximum Pressure
105 Pa
145 Pa
Fan Speed
2500 RPM
2500 RPM
Sound Level
38 dB(A)
44 dB(A)
Max. Operating Temp
40oC
40oC
IP Rating
IPX4
IPX4
Performance - WhisperVent 100
Performance - WhisperVent 150
Airflow (m³/hr)
0
50
100
150
200
250
300
350
400
160
50
100
150
200
250
140
120
Pressure (Pa)
100
80
60
40
20
15
30
45
60
75
0
0
20
40
60
80
100
120
Airflow (l/s)
Thomas and Betts | www.manrose.com.au | [email protected]
19
Manrose CLASSIC Multi-Vent Fans
FLUSH FITTING RANGE
Duct Size Model No.
Switching
Method
Performance @
Speed 3
Order Code
100mm
FFCF234S
Standard
65 l/s, 234m3/hr
FAN0038
100mm
FFCF234T
Timer
65 l/s, 234m3/hr
FAN0499
100mm
FFCF234PIR
PIR
65 l/s, 234m3/hr
FAN0501
SURFACE MOUNT RANGE
Flush Fitting Range
Duct Size Model No.
Switching
Method
Performance @
Speed 3
Order Code
100mm
SMCF234S
Standard
65 l/s, 234m3/hr
FAN0504
100mm
SMCF234T
Timer
65 l/s, 234m3/hr
FAN0505
•
•
•
Designed for apartments where space is limited, with a choice of
wall or ceiling mounted system.
These Models include centrifugal fans with a choice of three in-built
speed settings depending on the performance required.
Supported by a 2 year warranty.
Manrose CLASSIC WALL FAN
CF CENTRIFUGAL MODELS
Duct Size Model No.
Switching
Method
Performance @
Speed 1
Order Code
100mm
CF200S
Standard
31 l/s, 110m3/hr
FAN0041
100mm
CF200TP
Timer
31 l/s, 110m3/hr
FAN0042
CF Centrifugal Model
• Designed to move air over long distances.
• The centrifugal fan design provides efficient airflow and quiet operation.
• Supported by a 2 year warranty.
2
YEAR WARRANTY
1. Standard Model - operates from remote switch (not supplied).
3. PIR Model - Motion sensor incorporated in fan. Range up to 5 metres.
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off - adjustable 1-20 minutes.
Requires three wires: permanent phase, switched phase, neutral.
NOTE: All fan flow rates quoted are free air delivery.
20
TECHNICAL DATA
DIMENSION INFORMATION (mm)
Models
A
B
C
D
E
F
G
H
Multi-Vent FFCF234
91
96
141
250
15
155
210
-
Multi-Vent SMCF234 312
250
15
119.5
22.5
63
249
-
CF200
65
185
260
45
98
90
135
65
Dimensions - CF200
Dimensions - Multi-Vent (Flush Fitting)
B
Dimensions - Multi-Vent (Surface Mount)
B
C
A
G
E
E
A
C
F
C
A
G
H
D
D
E
F
G
G
D
D
B
TECHNICAL SPECIFICATION
Models
Multi-Vent
CF200
1 Speed
2 Speed
3 Speed
Power
220 - 240V
220 - 240V
220 - 240V
220 - 240V
Fan Performance
28 l/s, 100m3/hr
45 l/s, 162m3/hr
65 l/s, 234m3/hr
31 l/s, 110m3/hr
Fan Wattage
40W
80W
110W
45W
Maximum Pressure
140 Pa
165 Pa
180 Pa
120 Pa
Fan Speed
950 RPM
1500 RPM
1850 RPM
1400 RPM
Sound Level
37 dB(A)
51 dB(A)
56 dB(A)
45 dB(A)
Max. Operating Temp
50°C
50°C
50°C
50°C
IP Rating
IPX4
IPX4
IPX4
IPX4
Performance - CF200
Performance - Multi-Vent
Volume m3/hr
0
54
108
162
216
270
60
75
200
180
160
Static Pressure Pa
140
120
100
2
80
3
1
60
40
20
0
0
15
30
45
Volume l/sec
NOTE 1, 2, 3 refer to speed settings controlled by internal switch (not consumer adjustable).
Thomas and Betts | www.manrose.com.au | [email protected]
21
Manrose Pro-Series THRU WALL mounted FAN kits
XPLP Low Profile Models
STANDARD Models
Duct Size Model No.
125mm
XPLP125SS
Switching
Method
Performance
Order Code
Standard
36 l/s, 130m3/hr
FAN0614
3
125mm
XPLP125ST
Timer
36 l/s, 130m /hr
FAN0615
150mm
XPLP150SS
Standard
87 l/s, 313m3/hr
FAN0621
150mm
XPLP150ST
Timer
3
87 l/s, 313m /hr
FAN0623
Standard Models
Safety extra low voltage (selv) models
Duct Size Model No.
Switching
Method
Performance
Order Code
125mm
XPLP125SLV
SELV 12V
36 l/s, 130m3/hr
FAN0620
125mm
XPLP125CLV
SELV 12V
36 l/s, 130m3/hr
FAN0735
3
150mm
XPLP150SLV
SELV 12V
87 l/s, 313m /hr
FAN0732
150mm
XPLP150CLV
SELV 12V
87 l/s, 313m3/hr
FAN0738
Low Voltage Models
Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a
transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).
ACCESSORIES
Satin Silver Fascia
FAN2068
125mm
Chrome Fascia
FAN0755
150mm
Satin Silver Fascia
FAN2071
150mm
Chrome Fascia
FAN0598
Duct Size
Description - Circular
Order Code
125mm
Satin Silver Fascia
FAN2069
125mm
Chrome Fascia
FAN0757
150mm
Satin Silver Fascia
FAN2070
150mm
Chrome Fascia
FAN0613
•
•
•
The unique Low Profile design enables these fans to be installed unobtrusively
into any wall (requires a minimum wall cavity of 110mm).
These axial fans have been upgraded with ball bearing motors to prolong the life of the motor.
Supported by a 5 year warranty.
Accessories - Square
Accessories - Circular Fascia
R
125mm
EA
Order Code
LB
Description - Square
BAL
Duct Size
Note
1. Standard Model - operates from remote switch (not supplied).
3. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3.
2. Timer Model - Fan operates from a switch, the fan continues to run for a preset time after switching off - adjustable 1-20 minutes. Requires permanent phase and switched phase.
NOTE: All fan flow rates quoted are free air delivery.
22
GM
OT O R
5
IN
YEAR WARRANTY
Technical data
GENERAL INFORMATION
Models
Fan Cut-Out Size
Exterior Grille
Duct Type
Duct Length
XPLP125
140mm
White Gravity Shutter
Aluminium Semi-Rigid
375mm
XPLP150
173mm
White Gravity Shutter
Aluminium Semi-Rigid
375mm
Please note: Fan cut out size is a nominal diameter.
DIMENSION INFORMATION (mm)
Models
A
B
C
D
E
F
G
H
I
XPLP125
161
118
128
10
160
125
375
123
30
XPLP150
191
150
132
10
174
150
375
148
30
Dimensions - XPLP
I
E
G
H
F
B
A
C
D
TECHNICAL SPECIFICATION
Models
XPLP125
XPLP150
Power
220 - 240V (LV models 12V)
220 - 240V (LV models 12V)
Fan Performance
36 l/s, 130m /hr
87 l/s, 313m3/hr
Fan Wattage
20W
25W
Maximum Pressure
35 Pa
60 Pa
Fan Speed
2000 RPM
2400 RPM
Sound Level
41 dB(A)
40 dB(A)
Max. Operating Temp
50°C
50°C
IP Rating
IPX4
IPX4
Performance - XPLP125
3
Performance - XPLP150
Thomas and Betts | www.manrose.com.au | [email protected]
23
Manrose CLASSIC THRU WALL MOUNTED FAN KITS
XP Models
STANDARD Models
Duct
Size
Model No.
Switching
Method
Performance
Order
Code
100mm
XP100S
Standard
23 l/s, 85m3/hr
FAN0053
100mm
100mm
125mm
XP100P
XP100T
XP125S
3
Pull Cord
23 l/s, 85m /hr
FAN0054
3
Timer
23 l/s, 85m /hr
Standard
FAN0055
3
FAN0080
3
36 l/s, 130m /hr
125mm
XP125P
Pull Cord
36 l/s, 130m /hr
FAN0082
125mm
XP125T
Timer
36 l/s, 130m3/hr
FAN0083
150mm
150mm
150mm
XP150S
XP150P
XP150T
Standard
3
FAN0135
3
FAN0140
3
FAN0141
87 l/s, 313m /hr
Pull Cord
87 l/s, 313m /hr
Timer
87 l/s, 313m /hr
Standard Models
AUTO SHUTTER Models
Order
Code
150mm
XP150A
Standard
87 l/s, 313m3/hr
FAN0136
150mm
150mm
XP150AP
XP150AT
Pull Cord
Timer
3
FAN0137
3
FAN0138
87 l/s, 313m /hr
87 l/s, 313m /hr
Safety extra low voltage (selv) models
Duct
Size
Model No.
Switching
Method
Performance
Order
Code
100mm
XP100LV
SELV 12V
25 l/s, 85m3/hr
FAN0409
3
125mm
XP125LV
SELV 12V
36 l/s, 130m /hr
FAN0410
150mm
XP150LV
SELV 12V
87 l/s, 313m3/hr
FAN0411
Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not
include a transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).
•
•
•
These fans are designed to be ducted straight through an exterior
wall and are efficient and easy to install.
These axial fans have been upgraded with ball bearing motors to prolong the life of the motor.
Supported by a 5 year warranty.
Auto Shutter Models
Low Voltage Models
R
Performance
EA
Switching
Method
LB
Model No.
BAL
Duct
Size
Note
1. Standard Model - operates from remote switch (not supplied).
3. Pull Cord Model - Integral pull cord switch on fan.
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off - adjustable 1-20 minutes.
Requires three wires: permanent phase, switched phase, neutral.
4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts.
5. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3.
NOTE: All fan flow rates quoted are free air delivery.
24
GM
OT O R
5
IN
YEAR WARRANTY
Technical data
GENERAL INFORMATION
Models
Fan Cut-Out Size
Exterior Grille
Duct Type
Duct Length
XP100
112mm
Grey Gravity Shutter
Aluminium Semi-Rigid
375mm
XP125
135mm
Grey Gravity Shutter
Aluminium Semi-Rigid
375mm
XP150
160mm
Grey Gravity Shutter
Aluminium Semi-Rigid
375mm
Please note: Fan cut out size is a nominal diameter.
DIMENSION INFORMATION (mm)
Models
A
B
C
D
E
F
G
H
I
XP100
155
98
74
27
138
100
375
98
30
XP125
168
118
74
27
160
125
375
123
30
XP150
200
148
74
27
174
150
375
148
30
XP150A
200
148
90
55
174
150
375
148
30
Dimensions - XP
C
I
E
D
G
H
F
B
A
TECHNICAL SPECIFICATION
Models
XP100
XP125
XP150
Power
220 - 240V (SELV models 12V)
220 - 240V (SELV models 12V)
220 - 240V (SELV models 12V)
Fan Performance
23 l/s, 85m³/hr
36 l/s, 130m³/hr
87 l/s, 313m³/hr
Fan Wattage
20W
20W
25W
Maximum Pressure
20 Pa
35 Pa
60 Pa
Fan Speed
2400 RPM
2000 RPM
2400 RPM
Sound Level
41 dB(A)
41 dB(A)
40 dB(A)
Max. Operating Temp
50°C
50°C
50°C
IP Rating
IPX4
IPX4
IPX4
Performance - XP100
Performance - XP125
Performance - XP150
Thomas and Betts | www.manrose.com.au | [email protected]
25
Manrose CLASSIC WINDOW MOUNTED FANS
WF Models
STANDARD Models
Duct Size Model No.
Switching Method
Performance
Order Code
100mm
WF100P
Pull Cord
23 l/s, 85m3/hr
FAN0021
100mm
WF100PLV
Low Voltage
23 l/s, 85m3/hr
FAN0452
Manual SHUTTER Models
Standard Models
Duct Size Model No.
Switching Method
Performance
Order Code
150mm
WF150MP
Pull Cord
87 l/s, 313m3/hr
FAN0110
150mm
WF150MPLV
SELV 12
87 l/s, 313m3/hr
FAN0355
Please Note: An isolating transformer is required for all low voltage fans. Low Voltage models do not include a
transformer. (We recommend a SELV isolating transformer Order Code: FAN2402).
AUTO SHUTTER Models
Duct Size Model No.
Switching Method
Performance
Order Code
150mm
WF150AP
Pull Cord
87 l/s, 313m3/hr
FAN0107
150mm
WF150APT
Pull Cord Timer
87 l/s, 313m3/hr
FAN0109
Designed for use in situations where an existing window fan is being replaced
or where there is no available external wall space or ceiling space access.
These axial fans have been upgraded with ball bearing motors to prolong the
life of the motor and are Supported by a 5 year warranty.
Auto Shutter Models
BAL
LB
EA
R
•
•
GM
OT O R
5
IN
YEAR WARRANTY
Switching Options
1. Standard Model - operates from remote switch (not supplied).
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off - adjustable 1-20 minutes.
3. Pull Cord Model - Integral pull cord switch on fan.
4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts.
5. Manual Pull cord - Pull cord operates fan and manual shutters.
6. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3.
NOTE: All fan flow rates quoted are free air delivery.
26
Technical data
GENERAL INFORMATION
Models
Glass Cut-Out Size
WF100
115mm - 155mm
WF150
165mm - 190mm
Please note: Glass cut out size is a nominal diameter for a circular cut-out.
DIMENSION INFORMATION (mm)
Models
A
B
C
Dimensions - WF
B
D
WF100
163
90
30
163
WF150
203
118
23
203
A
C
D
TECHNICAL SPECIFICATION
Models
WF100
WF150
Power
220 - 240V
220 - 240V (SELV models 12V)
Fan Performance
23 l/s, 85m³/hr
87 l/s, 313m³/hr
Fan Wattage
20W
25W
Maximum Pressure
20 Pa
60 Pa
Fan Speed
2400 RPM
2400 RPM
Sound Level
41 dB(A)
40 dB(A)
Max. Operating Temp
50oC
50oC
IP Rating
IPX4
IPX4
Performance - WF100
Performance - WF150
Thomas and Betts | www.manrose.com.au | [email protected]
27
Manrose CLASSIC WINDOW COMMERCIAL FANS
WF Commercial MODELS
Standard Models
Duct Size Model No. Switching Method
Performance
Order Code
230mm
WF230P
Pull Cord
152 l/s, 550m3/hr
FAN0148
300mm
WF300P
Pull Cord
306 l/s, 1100m3/hr
FAN0481
AUTO SHUTTER Models
Standard Larger Models
Duct Size Model No. Switching Method
Performance
Order Code
230mm
WF230AP
Pull Cord
152 l/s, 550m3/hr
FAN0146
300mm
WF300A
Standard
306 l/s, 1100m3/hr
FAN0482
•
•
Designed for use in situations where an existing window fan is being replaced
or where there is no available external wall space or ceiling space access.
These axial fans have been upgraded with ball bearing motors to prolong
the life of the motor and are Supported by a 5 year warranty.
Auto Shutter Models
Manrose CLASSIC WINDOW COMMERCIAL FANS
COM Commercial Models
Duct Size Model No.
Switching Method
Performance
Order Code
230mm
COM230A
Standard
185 l/s, 670m3/hr
FAN0519
230mm
COM230MP Pull Cord
185 l/s, 670m3/hr
FAN0518
300mm
COM300A
Standard
280 l/s,1020m3/hr
FAN0521
300mm
COM300MP Pull Cord
280 l/s,1020m3/hr
FAN0520
Commercial Auto
Shutter Models
BAL
LB
EA
R
• Designed for commercial applications such as pubs, restaurants, hotels, shops etc.
• These axial fans include ball bearing motors to prolong the life of the motor.
• Supported by a 5 year warranty.
GM
OT O R
5
IN
YEAR WARRANTY
Switching Options
1. Standard Model - operates from remote switch (not supplied).
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off - adjustable 1-20 minutes.
3. Pull Cord Model - Integral pull cord switch on fan.
4. Auto Shutters - Electrically operated louvre shutters open automatically when fan is running - prevents back-draughts.
5. Manual Pull cord - Pull cord operates fan and manual shutters.
6. SELV Models - Suitable for installation in damp areas, zones 1, 2 and 3.
NOTE: All fan flow rates quoted are free air delivery.
28
Technical data
GENERAL INFORMATION
Models
Glass Cut-Out Size
WF230
255mm - 270mm
WF300
310mm - 345mm
COM230
255mm - 270mm
COM300
310mm - 345mm
Dimensions - WF230/300
C
B
Please note: Glass cut out size is a nominal diameter for a circular cut-out.
A
DIMENSION INFORMATION (mm)
D
E
Dimensions - COM230/300
Models
A
B
C
D
E
WF230
286
286
4-32
112
25
WF300
362
362
4-32
133
29
COM230
286
125
25
154
-
COM300
362
145
25
170
-
A
B
A
D
C
TECHNICAL SPECIFICATION
Models
WF230
Power
220 - 240V
WF300
COM230
220 - 240V
3
COM300
220 - 240V
3
220 - 240V
3
Fan Performance
152 l/s, 550m /hr
306 l/s, 1100m /hr
185 l/s, 670m /hr
280 l/s, 1020m3/hr
Fan Wattage
45W
82W
45W
82W
Maximum Pressure
50 Pa
60 Pa
50 Pa
60 Pa
Fan Speed
1250 RPM
1300 RPM
1600 RPM
1300 RPM
Sound Level
50 dB(A)
60 dB(A)
53 dB(A)
60 dB(A)
Max. Operating Temp
50°C
50°C
50°C
50°C
Performance
- WF230
Volume m 3/hr
0
250
500
750
Performance
- WF300
Performance
- COM230
Volume m 3/hr
300
600
900
1200
1500
0
83
168
250
333
416
Performance
- COM300
55
Static Pressure Pa
Static Pressure Pa
55
0
40
40
25
25
0
0
0
70
140
Volume l/sec
210
Volume l/sec
Thomas and Betts | www.manrose.com.au | [email protected]
29
Manrose PRO-SERIES HEAT/FAN/LIGHT KITS
Heat ‘n Vent Models
Duct Size Model No.
Performance
Order Code
125mm
Heat ‘n Vent 4
60 l/s, 216m3/hr
FAN0995
125mm
Heat ‘n Vent 2
50 l/s, 180m3/hr
FAN0940
ACCESSORIES
Pro-Series Heat ‘n Vent 4
Duct Size Description
Order Code
125mm
Heat ‘n Vent 4 Silver Fascia
FAN1015
125mm
Heat ‘n Vent 2 Silver Fascia
FAN1014
275W Heat Lamp
LHT0081
50W Halogen GU10 lamp
LHT0140
Pro-Series Heat ‘n Vent 2
•
•
•
With a 40% increase in performance* these systems meet the demands
of larger bathrooms and the stylish fascia blends into the decor.
These high efficiency centrifugal fans incorporate a unique anti-condensate design feature.
Supported by a 5 year warranty.
Manrose CLASSIC Heat/FAN/LIGHT KIT
Heat ‘n Vent 2
Duct Size Model No.
Performance
Order Code
100mm
35 l/s, 126m3/hr
FAN2162
Heat ‘n Vent 2
• This system delivers instant heat combined with ventilation and
soft lighting to create a comfort area in small bathrooms.
• Supported by a 5 year warranty.
Classic Heat ‘n Vent 2
Manrose CLASSIC Heat/LIGHT KIT
2 Heat ‘n LIGHT
FAN2200
2 Heat ‘n Light (excludes fan)
2 Heat ‘n Light
BAL
• This system provides instant heat and additional lighting.
• For a complete bathroom solution an extraction fan can be added.
• Supported by a 5 year warranty.
R
100mm
EA
Order Code
LB
Duct Size Description
GM
OT O R
5
IN
YEAR WARRANTY
Switching Options
1. Standard Model - operates from remote switch (not supplied).
*Increase in performance is based on the comparison to the
previous models.
30
NOTE: All fan flow rates quoted with 3 metres of duct, one bend
and one external grille (normal installation).
Technical data
GENERAL INFORMATION
Models
Cut-Out Size
Exterior Grille
Duct Type
Duct Length
PS Heat ‘n Vent 4
300mm x 300mm
White Eggcrate
Aluminium
3m supplied (you can add up to 3m extra duct)
PS Heat ‘n Vent 2
390mm x 210mm
White Eggcrate
Aluminium
3m supplied (you can add up to 3m extra duct)
Classic Heat ‘n Vent 2 390mm x 220mm
White Eggcrate
Aluminium
3m supplied (you can add up to 3m extra duct)
Classic Heat ‘n Light
-
-
-
390mm x 220mm
DIMENSION INFORMATION (mm)
Models
A
B
C
D
PS Heat ‘n Vent 4
338
338
170
120
PS Heat ‘n Vent 2
435
260
185
120
Heat ‘n Vent
450
250
195
100
Heat ‘n Light
450
250
195
100
Dimensions - PS Heat ‘n Vent 2
Dimensions - PS Heat ‘n Vent 4
Dimensions - Classic Heat ‘n Vent
D
C
B
A
Dimensions - Classic 2 Heat ‘n Light
D
D
C
C
C
B
B
B
A
A
TECHNICAL SPECIFICATION
Models
PS Heat ‘n Vent 4
PS Heat ‘n Vent 2
Heat ‘n Vent 2
2 Heat ‘n Light
Power
220 - 240V
220 - 240V
220 - 240V
220 - 240V
Fan
Centrifugal
Centrifugal
Centrifugal
-
Fan Performance
60 l/s, 216m³/hr
50 l/s, 180m³/hr
35 l/s, 126m³/hr
-
Heat Lamps
4 x 275W
2 x 275W
2 x 275W
2 x 275W
Light
GU10 Halogen
GU10 Halogen
GLES
GLES
Total Wattage
1180W
635W
670W
650W
Light Wattage
50W
50W
100W
100W
Switch Plate
4 sw. (supplied)
3 sw. (supplied)
3 sw. (supplied)
2 sw. (supplied)
Warranty
5 Years
5 Years
5 Years
5 Years
Performance Graph
Icon Key
36
72
108 144
03
180
02
216
252
01
288
01
Pro-Series Heat ‘n Vent 4
02
Pro-Series Heat ‘n Vent 2
03
Classic Heat 'n Vent 2
Note: Performance tested in free air.
70
Thomas and Betts | www.manrose.com.au | [email protected]
31
PRO-SERIES IN-LINE MOUNTED FAN KITS
MIXFLO™ Shower Fan Models
Duct Size Model No.
Switching Method
Performance
Order Code
100mm
Standard
69 l/s, 250m3/hr
FAN2049
150mm
MFLP125S
MFLP150S
Standard
Standard
3
89 l/s, 320m /hr
3
166 l/s, 597m /hr
FAN2050
FAN2051
MKLP150
BAL
LB
EA
• These powerful in-line mixed flow fans have been designed to produce higher working pressures for applications that require higher airflows with low relative noise levels.
• Supported by a 5 year warranty.
R
125mm
MFLP100S
Grille Cut-Out
Interior Grille
Exterior Grille
MFLP100 115mm
White Low Profile
White Low Profile Unilok Nude
6m supplied (you can add
up to 6m extra duct)
MFLP125 140mm
White Low Profile
White Low Profile Unilok Nude
6m supplied (you can add
up to 6m extra duct)
MFLP150 160mm
White Low Profile
White Low Profile Unilok Nude
6m supplied (you can add
up to 6m extra duct)
Please note: Grille cut out size is a nominal diameter for a circular cut-out.
Switching Options
1. Standard Model - operates from remote switch (not supplied).
32
OT O R
YEAR WARRANTY
GENERAL INFORMATION (KITS)
Models
GM
5
IN
Duct Type
Duct Length
Technical data
Dimension INFORMATION (mm)
Models
A
B
C
D
E
F
G
MF100
98
182
315
100
100
168
27
MF125
122
182
350
100
100
168
60
MF150
147
209
360
130
115
195
55
Dimensions - MF
TECHNICAL SPECIFICATION
Model
No
Size
(mm)
MF100
100
MF125
125
MF150
150
RPM Watts
Maximum Airflow
(m³/hr)
Maximum
Pressure (Pa)
2300 40
250
180
1700 18
190
120
2300 40
320
220
1700 18
260
160
2700 70
597
300
2000 60
330
240
Performance - MF100
50
100
150
IP
Rating
X4
45
43
X4
45
47
X4
60
Performance - MF150
Airflow (m3/hr)
200
250
300
0
50
100
150
Airflow (m3/hr)
200
250
300
0
350
250
200
100
200
300
400
500
600
700
350
180
300
200
160
250
140
120
100
80
Pressure (Pa)
150
Pressure (Pa)
Pressure (Pa)
Max Operating
Temp °C
40
Performance - MF125
Airflow (m3/hr)
0
Lp dB(A)
3m*
100
200
150
100
60
50
40
50
20
0
0
0
20
40
60
0
0
80
20
Airflow (L/s)
40
60
80
Airflow (L/s)
100
0
50
100
150
200
Airflow (L/s)
* Lp dB(A) @ 3 metres - sound pressure based on the high speed for each fan.
SOUND POWER LEVEL (high speed)
Model No
Sound Power Levels Lw (dB)
Octave band centre frequency in Hz
LwA
dB(A)
125
250
500
1000 2000 4000 8000
MF100
50
56
58
58
52
47
37
61
MF125
52
59
60
60
56
49
41
63.5
MF150
58
66
65
63
62
54
46
67.5
Thomas and Betts | www.manrose.com.au | [email protected]
33
Manrose PRO-SERIES IN-LINE FANS KITS
SFLP Shower Fan Models
Model No.
Switching
Method
Fan Type
Performance
Order Code
125mm
SFLP125S
Standard
Ctr’fgl
39 l/s, 140m³/hr
FAN0616
125mm
SFLP125T
Timer
Ctr’fgl
39 l/s, 140m³/hr
FAN0617
150mm
SFLP150S
Standard
Whisper
94 l/s, 340m³/hr
FAN0618
150mm
SFLP150T
Timer
Whisper
94 l/s, 340m³/hr
FAN0619
SFLP150
BAL
LB
EA
R
Duct
Size
GM
OT O R
5
IN
YEAR WARRANTY
• These high efficiency in-line fans are designed to provide
higher levels of extraction for today’s larger bathrooms.
• Supported by a 5 year warranty.
General INFORMATION
Models
Grille
Cut-Out
Interior Grille
Exterior Grille
Duct Type
Length of Duct included
SFLP125 140mm
White Low Profile
White Low Profile
Flexible
Aluminium
4m supplied (can be
extended up to 6m)
SFLP150 160mm
White Low Profile
White Low Profile
Flexible
PVC
5m supplied (can be
extended up to 12m)
Please note: Grille cut out size is a nominal diameter for a circular cut-out.
Switching Options
1. Standard Model - operates from remote switch (not supplied).
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off. The 100 and 125mm models are
adjustable between 1-20 minutes, whereas the 150mm models include
34
a fixed 7 minute timer. Both require three wires: permanent phase,
switched phase.
NOTE: All fan flow rates quoted are free air delivery.
Performance will be affected by the length of ducting used.
Technical data
Dimension INFORMATION (mm)
Models
A
B
C
D
E
SFLP125
155
125
125
195
258
SFLP150
200
143
170
185
-
Dimensions - SFLP125
Dimensions - SFLP150
C
A
B
A
C
D
B
D
E
TECHNICAL SPECIFICATION
Models
SFLP125
SFLP150
Fan
CFD225
WhisperVent
Power
220 - 240V
220 - 240V
Fan Performance
39 l/s, 140m³/hr
94 l/s, 340m³/hr
Fan Wattage
20W
46W
Maximum Pressure
120 Pa
160 Pa
Fan Speed
1400 RPM
2750 RPM
Sound Level
45 dB(A)
38 dB(A)
Max. Operating Temp
50°C
80°C
IP Rating
IPX4
IPX2
Performance - SFLP125
Performance - SFLP150
36
72
108 144
180
216
252
70
288
324 360
90
Thomas and Betts | www.manrose.com.au | [email protected]
35
Manrose CLASSIC IN-LINE FAN KITS
SF Shower Fan Models
Model
No.
Switching
Method
Fan
Type
Performance
Order Code
100mm
SF100S
Standard
Axial
23 l/s, 85m3/hr
FAN0017
100mm
SF100T
Timer
Axial
23 l/s, 85m3/hr
FAN0018
100mm
SF200S
Standard
Ctr’fgl
31 l/s, 110m3/hr
FAN0328
100mm
SF200T
Timer
Ctr’fgl
31 l/s, 110m3/hr
FAN0329
125mm
SF125S
Standard
Axial
36 l/s, 130m3/hr
FAN0064
125mm
SF125T
Timer
Axial
36 l/s, 130m3/hr
FAN0065
150mm
SF150S
Standard
Axial
87 l/s, 320m3/hr
FAN0101
150mm
SF150T
Timer
Axial
87 l/s, 320m3/hr
FAN0102
SF150 Shower Fan Kit
•
•
•
BAL
LB
EA
R
Duct Size
GM
YEAR WARRANTY
With the fan mounted in the ceiling space, these in-line models are
able to draw steam directly from source.
These fans have been upgraded with ball bearing motors to prolong
the life of the motor.
Supported by a 5 year warranty.
GENERAL INFORMATION
Duct Type
Models
Grille Cut-Out
Interior Grille
Exterior Grille
SF100
115mm
White Circular
White Fixed Louvre Flexible PVC
3m supplied (should
not be extended)
SF200
115mm
White Circular
White Fixed Louvre Flexible Alum
3m supplied (can be
extended up to 6m)
SF125
140mm
White Circular
White Fixed Louvre Flexible PVC
4m supplied (should
not be extended)
SF150
160mm
White Circular
White Fixed Louvre Flexible PVC
5m supplied (can be
extended up to 12m)
Length of Duct included
Please note: Grille cut out size is a nominal diameter for a circular cut-out.
Switching Options
1. Standard Model - operates from remote switch (not supplied).
a fixed 7 minute timer. Both require: permanent phase and switched phase.
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off. The 100 and 125mm models are
adjustable between 1-20 minutes, whereas the 150mm models include
NOTE: All fan flow rates quoted are free air delivery.
36
OT O R
5
IN
Performance will be affected by the length of ducting used.
Technical data
DIMENSION INFORMATION (mm)
Models
A
B
C
D
E
SF100
130
155
90
100
27
SF200
155
100
100
195
258
SF125
150
155
99
118
27
SF150
187
153
109
150
27
TECHNICAL SPECIFICATION
Models
SF100
SF200
SF125
SF150
Fan
ID100
CFD200
ID125
Hyper
Power
220 - 240V
220 - 240V
220 - 240V
220 - 240V
Fan Performance
23 l/s,
85m³/hr
31 l/s,
110m³/hr
36 l/s,
130m³/hr
89 l/s,
320m³/hr
Fan Wattage
20W
20W
20W
38W
Maximum Pressure
20 Pa
120 Pa
35 Pa
135 Pa
Fan Speed
2400 RPM
1400 RPM
2000 RPM
2650 RPM
Sound Level
41 dB(A)
45 dB(A)
41 dB(A)
46 dB(A)
Max Operating Temp
50°C
50°C
50°C
70°C
IP Rating
IPX4
IPX4
IPX4
IPX2
Performance - SF100
Performance - SF125
Dimensions - SF100/SF125/150
C
D
A
E
B
Dimensions - SF200
B
A
C
D
E
Performance - SF200
Performance - SF150
Note: PERFORMANCE - ID Fans maximum fan
performance stated, this can vary depending on
the length of ducting used.
Thomas and Betts | www.manrose.com.au | [email protected]
37
Manrose PRO-SERIES IN-LINE FAN/LIGHT KITS
ELLP Extract-a-lite Low Profile Models
Duct Size
Model No.
Switching
Method
Performance
Order Code
125mm
ELLP125WS - Wht
Standard
39 l/s, 140m3/hr
FAN2029
125mm
ELLP125WT - Wht
Timer
39 l/s, 140m3/hr
FAN2031
125mm
125mm
ELLP125SS - Slv
ELLP125ST - Slv
Standard
Timer
3
FAN2030
3
FAN2032
3
39 l/s, 140m /hr
39 l/s, 140m /hr
150mm
ELLP150WS - Wht
Standard
94 l/s, 340m /hr
FAN2033
150mm
ELLP150WT - Wht
Timer*
94 l/s, 340m3/hr
FAN2035
150mm
150mm
ELLP150SS - Slv
ELLP150ST - Slv
Standard
Timer*
3
FAN2034
3
FAN2036
94 l/s, 340m /hr
94 l/s, 340m /hr
ELLP125SW
* Includes a 7 minute fixed timer
These high efficiency in-line fans are designed to provide higher levels of extraction for larger bathrooms and include a stylish downlight.
White or satin silver finish available to complement your bathroom decor.
Electronic Transformer included in the kit to operate the 12V downlight.
Supported by a 5 year warranty.
LB
EA
R
ELLP150SS
BAL
•
•
•
•
ACCESSORIES
GM
OT O R
5
IN
YEAR WARRANTY
Duct Size
Description
Order Code
125mm
Pro-Series ELLP Diffuser White incl lamp
DCT1519
125mm
Pro-Series ELLP Diffuser Silver incl lamp
DCT1520
150mm
Pro-Series ELLP Diffuser White incl lamp
DCT1521
150mm
Pro-Series ELLP Diffuser Silver incl lamp
DCT1522
12V 35-50W Dichroic lamp with 60˚ angle beam
FAN0431
Electronic Transformer 12VAC 50kHz
FAN2101
125mm ELLP Diffusers
GENERAL INFORMATION
Models
Diffuser
Cut-Out
Interior
Exterior Grille
Duct Type
Length of Duct
included
ELLP125W
140mm
White Extract-a-lite
incl light
White Low
Profile
Black
Unilok
6m supplied (you can add
up to 6m extra duct)
ELLP125SS 140mm
Satin Silver Extract-a-lite
incl light
White Low
Profile
Black
Unilok
6m supplied (you can add
up to 6m extra duct)
ELLP150W
White Extract-a-lite
incl light
White Low
Profile
Black
Unilok
6m supplied (you can add
up to 6m extra duct)
Satin Silver Extract-a-lite
incl light
White Low
Profile
Black
Unilok
6m supplied (can be
extended up to 12m)
165mm
ELLP150SS 165mm
Please note: Diffuser cut out size is a nominal diameter for a circular cut-out.
Switching Options
1. Standard Model - operates from remote switch (not supplied).
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off. The 100 and 125mm models are
adjustable between 1-20 minutes, whereas the 150mm models include
38
a fixed 7 minute timer. Both require: permanent phase,
and switched phase.
NOTE: All fan flow rates quoted are free air delivery.
Performance will be affected by the length of ducting used.
Technical data
DIMENSION INFORMATION (mm)
Models
A
B
C
D
E
F
G
H
ELLP125
155
125
125
195
258
165
80
110
ELLP150
200
143
170
185
-
200
80
148
Dimensions - ELLP125 Fan
Dimension - ELLP150 Fan
Dimensions - ELLP Extract-a-lite Diffuser
C
A
B
A
C
D
H
B
G
D
F
E
TECHNICAL SPECIFICATION
Models
ELLP125
ELLP150
Fan
CFD225
WhisperVent
Power
220 - 240V
220 - 240V
Fan Performance
39 l/s, 140m³/hr
94 l/s, 340m³/hr
Fan Wattage
20W
46W
Maximum Pressure
120 Pa
160 Pa
Fan Speed
1400 RPM
2750 RPM
Light
12V 50W Halogen
12V 50W Halogen
Total Wattage
99W
96W
Sound Level
45 dB(A)
38 dB(A)
Max. Operating Temp
50°C
80°C
IP Rating
IPX4
IPX2
Performance - ELLP125
Performance - ELLP150
36
72
108 144
180
216
252
70
288
324 360
90
Thomas and Betts | www.manrose.com.au | [email protected]
39
Manrose CLASSIC IN-LINE FAN/LIGHT KITS
EL Extract-a-lite Models
EL100S
Standard
100mm
EL100T
125mm
Timer
EL125S
Standard
31 l/s, 110m3/hr
FAN0420
3
FAN0438
3
FAN2037
3
31 l/s, 110m /hr
36 l/s, 130m /hr
125mm
EL125T
Timer
36 l/s, 130m /hr
FAN2038
150mm
EL150S
Standard
89 l/s, 320m3/hr
FAN0803
150mm
EL150T
Timer*
89 l/s, 320m3/hr
FAN0804
EL150S
R
100mm
Order Code
EA
Switching Method Performance
LB
Model No.
BAL
Duct Size
OT O R
YEAR WARRANTY
* Includes a 7 minute fixed timer.
•
•
•
•
GM
5
IN
The fan is mounted in the ceiling space, and is therefore able to draw steam directly from source, while at the same time providing spot lighting within your bathroom.
These fans have been upgraded with ball bearing motors to prolong the life of the motor.
Electronic Transformer included in the kit to operate the 12V downlight.
Supported by a 5 year warranty.
ACCESSORIES
EL Diffuser white incl lamp
DCT0360
100mm
EL Diffuser chrome incl lamp
DCT0362
125mm
EL Diffuser white incl lamp
DCT2121
125mm
EL Diffuser chrome incl lamp
DCT2120
150mm
EL Diffuser white incl lamp
DCT1169
150mm
EL Diffuser chrome incl lamp
DCT1171
100mm
Accessory chrome bezel - Extract-a-lite
DCT0366
125mm
Accessory chrome bezel - Extract-a-lite
FAN2076
150mm
Accessory chrome bezel - Extract-a-lite
FAN0827
12V 35-50W Dichroic lamp with 60˚ angle beam
FAN0431
Electronic Transformer 12VAC 50kHz
125mm EL Diffusers
R
100mm
EA
Order Code
LB
Description
BAL
Duct Size
GM
OT O R
5
IN
YEAR WARRANTY
FAN2101
GENERAL INFORMATION
Models
Diffuser
Cut-Out
Interior
Exterior Grille Duct Type
Length of Duct included
EL100
115mm
White Extract-a-lite incl light
White Eggcrate
Flexible PVC
3m supplied (should not be extended)
EL125
145mm
White Extract-a-lite incl light
White Eggcrate
Flexible PVC
4m supplied (should not be extended)
EL150
165mm
White Extract-a-lite incl light
White Eggcrate
Flexible PVC
5m supplied (you can add up to 12m
extra duct)
Please note: Diffuser cut out size is a nominal diameter for a circular cut-out.
Switching Options
1. Standard Model - operates from remote switch (not supplied).
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off. The 100 and 125mm models are
adjustable between 1-20 minutes, whereas the 150mm models
40
include a fixed 7 minute timer. Both require: permanent phase and
switched phase.
NOTE: All fan flow rates quoted are free air delivery.
Performance will be affected by the length of ducting used.
Technical data
DIMENSION INFORMATION (mm)
Models
A
B
C
D
E
F
G
H
EL100
130
155
90
100
27
140
74
98
EL125
150
155
99
118
27
170
74
118
EL150
200
143
170
185
200
74
148
Dimensions - EL125
Dimensions - EL100
Dimensions - EL150 Fan
A
B
C
D
C
A
C
D
A
B
E
B
D
E
TECHNICAL SPECIFICATION
Models
EL100
EL125
EL150
Fan
CFD200
ID125
Hyper
Power
220 - 240V
220 - 240V
220 - 240V
Fan Performance
31 l/s, 110m3/hr
36 l/s, 130m3/hr
89 l/s, 320m3/hr
Fan Wattage
20W
25W
38W
Maximum Pressure
120 Pa
35 Pa
135 Pa
Fan Speed
1400 RPM
2000 RPM
2650 RPM
Light
12V 50W
Halogen
12V 50W
Halogen
12V 50W
Halogen
Total Wattage
70W
75W
88W
Sound Level
45 dB(A)
41 dB(A)
46 dB(A)
Max. Operating Temp
40°C
40°C
70°C
IP Rating
IPX4
IPX4
IPX2
Performance - EL100
Performance - EL125
Dimensions - EL Extract-a-lite Diffuser
H
G
F
Performance - EL150
36
72
108 144
180
216
252
70
288
324 360
90
Thomas and Betts | www.manrose.com.au | [email protected]
41
Pro-Series IN-LINE MIXED FLOW FANS
MIXFLO™ Fan Models
Duct
Size
Model
No.
Switching
Method
Speed
Setting
Performance @
High Speed
Order Code
100mm
MF100S
Standard
2 Speed
69 l/s, 250m3/hr
FAN1004
100mm
MF100T
Timer
2 Speed
69 l/s, 250m3/hr
FAN2124
100mm
MF100PL Plug & Lead
2 Speed
69 l/s, 250m3/hr
FAN1050
125mm
MF125S
Standard
2 Speed
89 l/s, 320m3/hr
FAN1005
125mm
MF125T
Timer
2 Speed
89 l/s, 320m3/hr
FAN2125
3
125mm
MF125PL Plug & Lead
2 Speed
89 l/s, 320m /hr
FAN1051
150mm
MF150S
Standard
2 Speed
166 l/s, 597m3/hr
FAN1006
150mm
MF150T
Timer
2 Speed
166 l/s, 597m3/hr
FAN2126
3
150mm
MF150PL Plug & Lead
2 Speed
166 l/s, 597m /hr
FAN1048
200mm
MF200S
Standard
3 Speed
272 l/s, 980m3/hr
FAN1007
200mm
MF200T
Timer
2 Speed
272 l/s, 980m3/hr
FAN2127
200mm
MF200PL Plug & Lead
3 Speed
272 l/s, 980m3/hr
FAN1053
• These powerful in-line mixed flow fans have been designed to produce higher working pressures for applications that require higher airflows with low relative noise levels.
• Supported by a four year warranty or 30,000 continuous hours.
Dimension information (mm)
Dimensions - MF
Models
A
B
C
D
E
F
G
MF100
98
182
315
100
100
168
27
MF125
122
182
350
100
100
168
60
MF150
147
209
360
130
115
195
55
MF200
197
244
354
142
140
230
50
Switching Options
1. Standard Model - operates from remote switch (not supplied).
NOTE: All fan flow rates quoted are free air delivery.
42
Mixflow 150mm Standard Model
4
YEAR WARRANTY
Technical data
technical specification
230V/50Hz/1Φ
Motor
Input
(W)
Max
Temp
(ºC)
Sound
Pressure
Level
(dBA@3m)
2300
0.40
45
40
1700
0.18
45
33
2300
0.40
45
43
1700
0.18
45
36
2700
0.70
60
47
2000
0.60
60
40
2700
0.85
60
48
2350
0.60
60
45
2000
0.45
60
41
Speed
(rev/
min)
Model
No.
MF100
MF125
MF150
MF200
Performance - MF100
SOUND POWER LEVEL (high speed)
125
250
500
1000
2000
4000
8000
MF100
50
56
58
58
52
47
37
MF125
52
59
60
60
56
49
41
MF150
58
66
65
63
62
54
46
MF200
65
69
64
63
62
60
48
Performance - MF125
Airflow (m3/hr)
0
50
100
Sound Power Levels LwA (dB) Octave
band centre frequency in Hz
Model No.
150
Airflow (m3/hr)
200
250
300
0
50
100
150
200
250
300
350
250
200
180
200
160
Icon Key
Pressure (Pa)
Pressure (Pa)
140
120
100
80
150
Speed 1
Speed 2
100
Speed 3
60
50
40
20
0
0
0
20
40
60
0
80
20
Airflow (L/s)
Performance - MF150
100
200
60
80
100
Performance - *MF200
300
400
*MF200 Timer model only has
2 speeds, therefore Medium
fan speed specifications will
not apply.
Airflow (m3/hr)
Airflow (m3/hr)
0
40
Airflow (L/s)
500
600
700
350
0
200
0
50
400
600
800
1000
300
300
250
250
Pressure (Pa)
Pressure (Pa)
200
200
150
100
150
100
50
50
0
0
50
100
Airflow (L/s)
150
200
0
100
150
200
250
300
Airflow (L/s)
Thomas and Betts | www.manrose.com.au | [email protected]
43
Manrose PRO-SERIES IN-LINE WHISPERVENT FAN
Duct Size Model No.
Switching
Performance
Method
150mm
Standard
94 l/s, 340m3/hr
FAN0916
LB
EA
R
This high efficiency in-line fan is designed to provide higher
levels of extraction with low relative noise.
The ball bearing motor prolongs the life of the motor.
Supported by a 5 year warranty.
BAL
•
•
•
Whispervent WVI150
Order Code
GM
OT O R
5
IN
YEAR WARRANTY
Manrose CLASSIC IN-LINE Hyper FAN
•
•
•
•
89 l/s, 320m3/hr
FAN0085
This high efficiency in-line fan is designed to provide high levels of extraction.
The ball bearing motor prolongs the life of the motor.
Includes 1.3m lead and 3 pin plug.
Supported by a 5 year warranty.
R
Standard
Hyper150
EA
150mm
Order Code
LB
Switching
Performance
Method
BAL
Duct Size Model No.
GM
OT O R
5
IN
YEAR WARRANTY
Switching Options
1. Standard Model - operates from remote switch (not supplied).
NOTE: All fan flow rates quoted are free air delivery.
44
Technical data
Dimension specification
Models
A
B
C
D
WVI150
200
143
170
185
Hyper150
200
143
170
185
TECHNICAL SPECIFICATION
Models
Whispervent WVI150
Hyper150
Power
220 - 240V
220 - 240V
Fan Performance
94 l/s, 340m³/hr
89 l/s, 320m³/hr
Fan Wattage
46W
38W
Maximum Pressure
160 Pa
135 Pa
Fan Speed
2750 RPM
2650 RPM
Sound Level
38 dB(A)
46 dB(A)
Max. Operating Temp
80°C
70°C
IP Rating
IPX2
IPX2
Performance - WhisperVent WVI150
36
72
108 144
180
216
Dimensions
C
A
B
D
Performance - Hyper150
252
70
288
324 360
90
36
72
108 144
180
216
252
70
288
324 360
90
Thomas and Betts | www.manrose.com.au | [email protected]
45
Manrose CLASSIC IN-LINE AXIAL FANS
ID Models
Duct Size
Model No.
Switching Method
Performance
3
Order Code
100mm
ID100S
Standard
23 l/s, 85m /hr
FAN0012
100mm
ID100T
Timer
23 l/s, 85m3/hr
FAN0013
125mm
ID125S
Standard
36 l/s, 130m3/hr
FAN0060
3
125mm
ID125T
Timer
36 l/s, 130m /hr
FAN0061
150mm
ID150S
Standard
87 l/s, 313m3/hr
FAN0090
150mm
ID150T
Timer
87 l/s, 313m3/hr
FAN0091
230mm
ID230S
Standard
152 l/s, 550m3/hr
FAN0405
230mm
ID230T
Timer
152 l/s, 550m3/hr
FAN0406
•
•
•
ID100/125/150
With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from the source.
These axial fans have been upgraded with ball bearing motors to prolong the life of the motor.
Supported by a 5 year warranty.
BAL
LB
EA
R
ID230
ECO IN-LINE AXIAL FANS
OT O R
YEAR WARRANTY
Duct Size
Model No.
Switching Method
Performance
Order Code
150mm
ECO150S
Standard
64 l/s, 230m3/hr
FAN2078
•
•
•
GM
5
IN
With the fan mounted in the ceiling space, these in-line models are able to draw steam directly from the source.
High quality sleeve bearing motor.
Supported by a 2 year warranty.
2
YEAR WARRANTY
Switching Options
1. Standard Model - operates from remote switch (not supplied).
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off - adjustable 1-20 minutes.
Requires three wires: permanent phase, switched phase, neutral.
46
NOTE: All fan flow rates quoted are free air delivery.
Technical data
Dimension specification
Models
A
B
C
D
E
ID100
130
155
90
100
27
ID125
150
155
99
118
27
ECO150 (white)
187
153
109
150
27
ID150
187
153
109
150
27
ID230 (square model)
286
286
155
230
-
Dimensions - ID Fans
C
D
A
E
B
TECHNICAL SPECIFICATION
Models
ID100
ID125
ECO150
ID150
ID230
Power
220 - 240V
220 - 240V
220 - 240V
220 - 240V
220 - 240V
Fan Performance
23 l/s, 85m³/hr
36 l/s, 130m³/hr 64 l/s, 230m³/hr 87 l/s, 313m³/hr 152 l/s, 550m³/hr
Fan Wattage
20W
20W
25W
25W
80W
Maximum Pressure
20 Pa
35 Pa
50 Pa
60 Pa
50 Pa
Fan Speed
2400 RPM
2000 RPM
2400 RPM
2400 RPM
1250 RPM
Sound Level
41 dB(A)
41 dB(A)
40 dB(A)
40 dB(A)
50 dB(A)
Max. Operating Temp
50°C
50°C
50°C
50°C
50°C
IP Rating
IPX4
IPX4
IPX4
IPX4
IPX4
Performance - ID100
Performance - ID125
Performance - ID150
Performance - ID230
Performance - ECO150
Note: PERFORMANCE - ID Fans maximum fan performance stated,
this can vary depending on the length of ducting used.
Thomas and Betts | www.manrose.com.au | [email protected]
47
Manrose CLASSIC IN-LINE CENTRIFUGAL FANS
CFD Models
Duct Size Model No.
Switch Method
Performance
Order Code
100mm
CFD200S
Standard
31 l/s, 110m³/hr
FAN0326
100mm
CFD200T
Timer
31 l/s, 110m³/hr
FAN0327
125mm
CFD225S
Standard
39 l/s, 140m³/hr
FAN2067
125mm
CFD225T
Timer
39 l/s, 140m³/hr
FAN2066
Manrose Classic In-Line
CF 125mm Standard
LB
EA
R
These high efficiency centrifugal fans are designed for
use where longer duct runs are required.
The ball bearing motor prolongs the life of the motor.
Supported by a 5 year warranty.
BAL
•
•
•
GM
OT O R
5
IN
YEAR WARRANTY
Technical data
SPECIFICATION
DIMENSION INFORMATION (mm)
Models
CFD200
CFD225
Models
A
B
C
D
E
Power
220 - 240V
220 - 240V
CFD200
155
100
100
195
258
Fan Performance
31 l/s, 110m³/hr
39 l/s, 140m³/hr
CFD225
155
125
125
195
258
Fan Wattage
20W
20W
Maximum Pressure
120Pa
120Pa
Fan Speed
1400 RPM
1400 RPM
Sound Level
45 dB(A)
45 dB(A)
Max. Operating Temp
50°C
50°C
IP Rating
IPX4
IPX4
Performance - CFD200
Performance - CFD225
Dimensions - CFD200/CFD225
B
C
A
E
Switching Options
1. Standard Model - operates from remote switch (not supplied).
3. Requires: permanent phase and switched phase.
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off - adjust able 1-20 minutes.
NOTE: All fan flow rates quoted are free air delivery.
48
D
SIMX in-line CENTRIFUGAL 3 SPEED FANS
High Performance Models
Duct Size
Model No. Performance @ Speed 3
Order Code
150mm
3 Speed
115 l/s, 415m³/hr
FAN0921
200mm
3 Speed
208 l/s, 750m³/hr
FAN0997
• Suitable for a variety of domestic and commercial applications, these in-line centrifugal fans provide high performance at your preset choice of speed.
• Supported by a 2 year warranty.
Please note: Can be used for supply or extract.
2
TECHNICAL DATA
DIMENSION INFORMATION (mm)
YEAR WARRANTY
Dimensions
Models
A
B
C
D
E
150mm
340
150
154
50
75
200mm
340
200
280
50
50
TECHNICAL SPECIFICATION
Models
150mm
200mm
Voltage/Freq (50hz)
220 - 240V
220 - 240V
Fan Performance Speed 1
65 l/s, 234m³/hr
125 l/s, 450m³/hr
Fan Performance Speed 2
90 l/s, 324m³/hr
170 l/s, 620m³/hr
Fan Performance Speed 3
124 l/s, 425m³/hr
205 l/s, 740m³/hr
Fan Wattage (at high speed)
65W
110W
Current (A) (at high speed)
0.36
0.38
Fan Speed (at high speed)
2460 RPM
2700 RPM
Sound Level*
43 dB(A)
56 dB(A)
Ambient Temp
50°C
60°C
* dB(A) - measured 1m free field.
Performance - 200mm 3 Speed
Performance - 150mm 3 Speed
200mm 3 Speed Centrifugal Fan Curve
400
Pressure (Pa)
300
200
100
100
200
300
400
500
600
700
800
900
1000
Airflow (m3/hr)
Thomas and Betts | www.manrose.com.au | [email protected]
49
SIMX IN-LINE FANS
High Performance Centrifugal Models
Duct Size
Model No
Performance
Order Code
100mm
MAN100
49 l/s, 176m3/hr
FAN0361
125mm
3
61 l/s, 220m /hr
MAN125
FAN0360
3
150mm
MAN150
115 l/s, 415m /hr
FAN0330
200mm
MAN200
208 l/s, 750m3/hr
FAN0467
250mm
315mm
3
FAN0358
3
FAN0357
280 l/s, 1010m /hr
MAN250
360 l/s, 1300m /hr
MAN315
• Suitable for a variety of domestic and commercial applications, these in-line centrifugal fans provide extremely high performance with a choice of sizes.
• Supported by a 2 year warranty.
Please note: Can be used for supply/extract.
Models
A
B
C
D
E
MAN100
250
100
136
50
70
MAN125
250
125
147
60
60
MAN150
340
150
154
50
75
MAN200
340
200
250
50
50
MAN250
320
249
310
65
65
MAN315
405
315
177
80
80
50
2
YEAR WARRANTY
DIMENSION INFORMATION (mm)
Dimensions
Simx 150mm In-Line Fan
TECHNICAL DATA
Technical INFORMATION
Models
MAN100
MAN125
MAN150
MAN200
MAN250
MAN315
Voltage/Freq (50hz)
220-240V
220-240V
220-240V
220-240V
220-240V
220-240V
Fan Performance
49 l/s,
176m³/hr
61 l/s,
220m³/hr
115 l/s,
415m³/hr
208 l/s,
750m³/hr
280 l/s,
1010m³/hr
360 l/s,
1300m³/hr
Fan Wattage
32W
31W
65W
110W
170W
200W
Maximum Pressure
153 Pa
143 Pa
320 Pa
418 Pa
500 Pa
590 Pa
Current (A)
0.14
0.13
0.35
0.45
0.76
0.87
Fan Speed (min -1)
2500 RPM
2490 RPM
2350 RPM
2520 RPM
2580 RPM
2410 RPM
Sound Level*
38 dB(A)
38 dB(A)
50 dB(A)
56 dB(A)
47 dB(A)
57 dB(A)
Max Operating Temp
60°C
60°C
50°C
60°C
50°C
45°C
* dB(A) - measured 1m free field.
Performance - MAN125
Performance - MAN100
Volume (m³/h)
0
20
40
Volume (m³/h)
60
0
80 100 120 140 160 180
100mm
100
150
200
250
0
100
100
80
80
60
60
Static Pressure (Pa)
120
40
20
0
0
10
20
30
125mm
140
120
40
0
10
20
30
Volume (m³/h)
0
450
40
50
60
200
400
400
300
350
250
300
800
0
150
200
250
20
40
Volume (m³/h)
0 200 400
1000
60
80
100
120
600
800
1000
1200
1400
600
315mm
250mm
500
400
300
200
Static Pressure (Pa)
Static Pressure (Pa)
Volume l/s
50
0
250
200
100
150mm
Performance - MAN315
600
450
200mm
350
50
400
100
70
500
0
350
Volume l/s
0 100 200 300 400 500 600 700 800 900
0
300
0
Volume (m³/h)
50
250
150
Performance - MAN250
100
200
200
20
50
150
150
250
Volume l/s
400
100
300
40
Volume l/s
Performance - MAN200
50
350
Static Pressure (Pa)
140
Static Pressure (Pa)
Volume (m³/h)
50
160
160
Static Pressure (Pa)
Performance - MAN150
150
100
50
0
0
50
Volume l/s
100
150
200
250
300
200
100
0
0
50
100
150
200
250
300
350
400
Volume l/s
Thomas and Betts | www.manrose.com.au | [email protected]
51
SIMX IN-LINE CENTRIFUGAL FANS
WhisperVent Low Profile Models
Duct Size
Model No
Performance
Order Code
150mm
WVILP150-1
124 l/s, 445m3/hr
FAN0829
150mm
WVILP150-3
118 l/s, 425m3/hr
FAN0830
•
•
Suitable for a variety of domestic and commercial applications, this in-line centrifugal fan offers high performance with a low profile design to enable this unit to be installed in confined spaces.
Supported by a 2 year warranty.
2
DIMENSION INFORMATION (mm)
YEAR WARRANTY
Models
A
B
C
D
E
WhisperVent Low Profile
313
168
148
340
218
Dimensions
A
D
E
B
52
ØC
TECHNICAL DATA
Technical specification
Models
Fan
Speed
FAN0830
1
65 l/s, 234m³/hr
FAN0830
2
FAN0830
FAN0829
Fan Performance
Norm Fan
Speed (RPM)
Single Phase
Nom Watts
Nom Amps
1440
50
0.22
90 l/s, 324m³/hr
1860
56
0.24
3
124 l/s, 445m³/hr
2460
80
0.36
1
118 l/s, 425m³/hr
2520
80
0.36
SOUND POWER LEVEL
Model No
Sound Power Levels Lw (A)
Octave band centre frequency in Hz
dB(A) @ 3m
63
125
250
500
1k
2k
4k
8k
FAN0830 - Speed 1
-
20
34
43
43
44
40
30
30
FAN0830 - Speed 2
-
26
40
51
51
52
45
38
36
FAN0830 - Speed 3
-
40
42
62
64
64
59
45
43
57
61
68
67
65
64
59
53
43
FAN0829
Performance - FAN0829 & FAN0830
Thomas and Betts | www.manrose.com.au | [email protected]
53
SIMX EXTERNAL WALL MOUNTED Fans
Extract MODELS
Duct Size
Fan Type
Air
Performance
Order Code
150mm
Axial
Extract*
73 l/s, 263m3/hr
FAN2303
150mm
Ctr’fgl (190 Motor)
Extract
109 l/s, 392m3/hr
FAN2425
150mm
Ctr’fgl (220 Motor)
Extract
133 l/s, 480m3/hr
FAN2424
*Also available in a Supply Air option
•
•
•
Designed for use in residential and light commercial applications
where a high performance, low noise solution is required.
Specific applications include apartments where space is limited.
Supported by a 2 year warranty.
150mm Ctr’fgl (190 Motor)
SIMX EXTERNAL WALL Mounted Fans
3 Speed Extract MODELS
Duct Size
Fan Type
Air
Performance
(High Speed)
Order Code
150mm
Ctr’fgl (190 Motor)
Extract
113 l/s, 408m3/hr
FAN2423
150mm
Ctr’fgl (220 Motor)
Extract
136 l/s, 493m3/hr
FAN2426
•
•
•
•
Designed for use in residential and light commercial applications
where a high performance, low noise solution is required.
Three speed models enable further flexibility in a variety of applications.
Specific applications include apartments where space is limited.
Supported by a 2 year warranty.
Wall mounted with measurements
369mm
369mm
305mm
110mm
110mm
305mm
Switching Options
1. Electrical connection must be made internally (Junction Box is only suitable for internal use).
NOTE: All fan flow rates quoted are free air delivery.
54
Fan Assembly - Line Drawing
2
YEAR WARRANTY
TECHNICAL DATA
PERFORMANCE DATA
Order
Code
Motor Size
Description
(mm)
FAN2303
150
FAN2425
Fan Performance
m³/hr
l/s
Watts @
230V
Axial
263
73
48
0.29
80
48
150
Centrifugal 190
Motor (1 Speed)
392
109
65
0.28
280
60
FAN2424
150
Centrifugal 220
Motor (1 Speed)
480
133
96
0.42
380
61
FAN2423
150
Centrifugal 190
Motor (3 Speed)
High Speed
408
113
65
0.28
280
60
Medium Speed
340
94
57
0.25
250
56
Low Speed
277
77
55
0.24
200
46
High Speed
493
136
96
0.42
380
61
Medium Speed
408
113
69
0.34
340
56
Low Speed
340
94
60
0.31
280
50
FAN2426
Amps
Static
Sound Level
Pressure (Pa) (dB(A) @ 3m)
Centrifugal 220
Motor (3 Speed)
150
400
350
Icon Key
300
Pressure (Pa)
250
200
FAN2303 150mm AXIAL
150
FAN2425 150mm CENTRIFUGAL (190 Motor)
100
50
FAN2424 150mm CENTRIFUGAL (220 Motor)
0
0
50
100
150
Airflow (L/s)
400
350
300
Pressure (Pa)
250
200
150
FAN2423 150mm 3 SPEED CENTRIFUGAL (190 Motor)
100
50
FAN2426 150mm 3 SPEED CENTRIFUGAL (220 Motor)
0
0
50
100
150
Airflow (L/s)
Thomas and Betts | www.manrose.com.au | [email protected]
55
THRU-ROOF MOUNTED FANS
Thru Roof Fan Cowl Models
Duct Size
150mm
150mm
150mm
Fan Type
Ctr’fgl
Ctr’fgl 3-spd
Axial - Whisper
Air
Extract
Extract
Extract
Performance
Order Code
3
FAN0529
3
FAN1002
153 l/s, 550m hr
153 l/s, 550m hr
3
FAN1009
3
89 l/s, 320m /hr
150mm
Axial
Extract
75 l/s, 270m /hr
FAN0531
150mm
Axial - Whisper
Supply
75 l/s, 270m3/hr
FAN0533
150mm Axial - Whisper
• High quality aluminium cowl construction, with fan incorporated, for longevity of operation.
• Supported by a 2 year warranty.
With Flashing & HDPE Tube
Duct Size
Fan Type
Air
Performance
Order Code
150mm
Ctr’fgl
Extract
153 l/s, 550m3hr
FAN0530
3
150mm
Ctr’fgl 3-spd
Extract
153 l/s, 550m hr
FAN0967
150mm
Axial - Whisper
Extract
89 l/s, 320m3/hr
FAN1060
3
150mm
Axial
Extract
75 l/s, 270m /hr
FAN0532
150mm
Axial
Supply
75 l/s, 270m3/hr
FAN0534
150mm
150mm
H/D Axial
H/D Ctr’fgl
Extract
Extract
3
75 l/s, 270m /hr
3
153 l/s, 550m hr
FAN0739
FAN0740
150mm Axial - Whisper
2
YEAR WARRANTY
H/D = Heavy Duty cowl used in these kits.
•
•
•
High quality aluminium cowl construction, with fan incorporated for
longevity of operation.
Includes Flashing for metal based roofs, an optional lead Flashing is
available for concrete tile roofs (DCT0190) at an additional cost.
Supported by a 2 year warranty.
Thru Roof Fan System Models
Duct Size
Description
Fan Type
Performance*
Order Code
150mm
Ultra
Ctr’fgl
153 l/s, 550m3/hr
FAN0535
150mm
•
•
•
Hyper
Hyper
3
75 l/s, 270m /hr
DCT0189
High quality aluminium cowl construction, with fan incorporated,
for longevity of operation.
Includes Flashing for metal based roofs, an optional lead Flashing is
available for concrete tile roofs (DCT0190) at an additional cost.
Supported by a 2 year warranty.
150mm Hyper Fan System
Connection
1. Electrical connection can be made inside or outside the roof space.
* NOTE: All fan flow rates quoted are motor performance in free air.
2
YEAR WARRANTY
56
TECHNICAL DATA
Dimension information (mm)
Dimensions - Thru Roof Fans
Models
A
B
C
FAN0529 - FAN1002
275
170
-
FAN1009
275
170
-
FAN0531- FAN0533
275
170
-
FAN0530 - FAN0967
275
170
500
FAN1060
275
170
500
FAN0532 - FAN0534
275
170
500
FAN0739 - FAN0740
275
170
500
A
B
C
TECHNICAL SPECIFICATION
Models
FAN0529
FAN0530
FAN0740
FAN1002
FAN0967
FAN0531
FAN0532
FAN0739
FAN0533
FAN0534
FAN1009
FAN1060
Supply Voltage
220-240VAC
220-240VAC
220-240VAC
220-240VAC
220-240VAC
Fan
Centrifugal
Axial
Axial
Axial - Whisper
Centrifugal
3
3
Fan Performance
153 l/s, 550m /hr
153 l/s, 550m /hr
75 l/s, 270m /hr
75 l/s, 270m /hr
89 l/s, 320m3/hr
Fan Wattage
58W
58W
44W
44W
46W
Maximum Pressure
320 Pa
320 Pa
80 Pa
130 Pa
130 Pa
Fan Speed
2500 RPM
2500 RPM
2850 RPM
2850 RPM
2750 RPM
Sound Level @ 1m
62 dB(A)
62 dB(A)
55 dB(A)
55 dB(A)
38 dB(A)
Operating Temp
-25 - +50°C
-25 - +50°C
-20 - +80°C
-20 - +80°C
-20 - +80°C
IP Rating
IPX4
IPX4
IPX2
IPX2
IPX2
Performance - FAN0529/FAN0530/FAN0740
3
3
Performance - FAN0531/FAN0532/FAN0739
90
350
80
300
70
60
Pressure (Pa)
Pressure (Pa)
250
200
150
50
40
30
100
20
50
10
0
0
50
100
150
0
200
0
20
40
Airflow (L/s)
FAN0530
/ FAN0555- FAN0533/FAN0534
Performance
80
100
120
Performance - FAN1009/FAN1060
FAN0532 / FAN0553
90
160
80
140
70
120
Pressure (Pa)
60
Pressure (Pa)
60
Airflow (L/s)
50
40
30
100
80
60
40
20
20
10
0
0
20
40
60
80
100
120
0
0
Airflow (L/s)
FAN0532 / FAN0553
50
100
150
Airflow (L/s)
FAN1009 / FAN1060
Thomas and Betts | www.manrose.com.au | [email protected]
57
Manrose PRO-SERIES HAND DRYERS
PUBLIC AREAS/HEAVY USAGE APPLICATIONS
NEW
Designed to provide a cost effective alternative to conventional Hand Dryers.
Providing a rapid drying time of 10 seconds, almost half that of the competitors
products, thus reducing washroom time.
Switching
Performance
Method
Model No.
Cover
MAN/E-88AE
Stainless
White
Steel
Auto
56 l/s, 200m3/hr
FAN2287
MAN/E-88AEBC
Stainless
Satin
Steel
Auto
56 l/s, 200m3/hr
FAN2286
•
•
•
•
Colour
Order Code
Heavy Usage
Hand Dryers
70% energy savings.
Tamper Proof Technology.
Suitable for use in public areas for heavy usage.
Supported by a 5 year warranty.
Manrose Hand Dryer
- MAN/E-88AE
Manrose CLASSIC HAND DRYERS
PUBLIC AREAS/HEAVY USAGE APPLICATIONS
Model No.
Cover
Colour
Switching
Performance
Method
MAN/M-88A
ABS Thermoplastic
White
Auto
56 l/s, 200m3/hr
FAN2902
MAN/A-89
3mm Aluminium
White
Auto
108 l/s, 388m3/hr
FAN4396
MAN/A-89S
3mm Aluminium
Silver
Auto
108 l/s, 388m3/hr
FAN4395
MAN/A-89B
3mm Aluminium
Black
Auto
108 l/s, 388m3/hr
FAN4397
MAN/E-88A
Porcelain Enamel
2mm Steel
White
Auto
130 l/s, 470m3/hr
FAN2903
•
•
Order Code
These models are suitable for use in public areas such as lavatories, factories, schools, railways and motorway service stations and are designed for heavy usage and unsupervised areas.
Supported by a 2 year warranty.
Manrose Hand Dryer
- MAN/E-88AEBC
Manrose MAN/M-88A
Manrose MAN/A-89
Colour Options available:
White, Silver and Black
Manrose MAN/E-88A
2
YEAR WARRANTY
58
TECHNICAL DATA
Dimension information
Dimension SPECIFICATION (mm) - Hand dryers
Model
A
B
C
MAN/E-88AE
201
277
175
MAN/E-88AEBC
201
277
175
MAN/M-88A
225
275
160
MAN/A-89
225
275
160
MAN/E-88A
284
248
202
TECHNICAL SPECIFICATION - Pro-Series
Dimensions - MAN/E-88AE Models,
MAN/E-88AEBC
Models
MAN/E-88AE
MAN/E-88AEBC
Power
220 - 240V
220 - 240V
Cover
Stainless Steel
Stainless Steel
Colour
White
Stainless Satin Steel
3
Fan Performance
56 l/s, 200m /hr
56 l/s, 200m3/hr
Operation
No touch infra-red
detection
No touch infra-red
detection
Heater Element
450 - 900W
adjustable
450 - 900W
adjustable
Power
1.6kW @ 240V
1.6kW @ 240V
Dry Time
10 secs
10 secs
Sound Level
74 dB(A)
74 dB(A)
Weight
7.0kg
7.0kg
A
B
C
Dimensions - MAN/M-88A, A-89,
A-89S A-89B
A
TECHNICAL SPECIFICATION - CLASSIC
B
Models
MAN/M-88A
MAN/A-89
MAN/E-88A
Power
220 - 240V
220 - 240V
220 - 240V
C
Depth
Cover
Colour
ABS Thermoplastic 3mm Aluminium
White
Fan Performance 56 l/s, 200m³/hr
Steel 2mm Porcelain
Enamel
White, Silver, Black
White
108 l/s, 388m3/hr
130 l/s, 470m³/hr
Operation
No touch infra-red
detection
No touch infra-red
detection
No touch infra-red
detection
Power
1.5kW @ 240V
2.0kW @ 240V
2.4kW @ 240V
Sound Level
54 dB(A)
69 dB(A)
70 dB(A)
Weight
3.3kg
4.7kg
7.5kg
Dimensions - MAN/E-88A
A
Thomas and Betts | www.manrose.com.au | [email protected]
B
Depth
C
59
SPECIALISED FANS
Frame Fan Model
Duct Size
Model No.
Switching Method
Performance
120mm
Frame Fan
Standard
38 l/s, 138m³/hr FAN0397
150mm
Frame Fan
Standard
89 l/s, 320m³/hr FAN1043
•
•
•
Order Code
This frame fan is designed for use in computer rooms or applications
where the introduction of cool air is required for small enclosed spaces.
The ball bearing motor prolongs the life of the motor.
Supported by a 2 year warranty.
Frame Fan 125mm
ACCESSORIES
Duct Size
Description
Order Code
120mm
Finger Guard for FAN0397 - Metal
FAN0412
120mm
Filter Guard for FAN0397
FAN0413
150mm
Finger Guard for FAN1043
FAN0841
TECHNICAL DATA
2
Technical information
YEAR WARRANTY
Models
Frame Fan 125
Frame Fan 150
Power
220 - 240V
220 - 240V
Fan Performance
38 l/s, 138m³/hr
89 l/s, 320m³/hr
Fan Wattage
15W
38W
Models
A
B
C
Maximum Pressure
62Pa
135Pa
Frame Fan 125
120
120
105 40
Fan Speed
2650 RPM
2650 RPM
Frame Fan 150
172
150
160 51
Sound Level
43 dB(A)
46 dB(A)
Max. Operating Temp
80°C
70°C
IP Rating
IPX4
IPX2
Performance - 125mm Frame Fan
Dimension SPECIFICATION
Performance - 150mm Frame Fan
Dimensions - Frame Fan
D
36
72
108 144
180
216
252
288
D
324 360
A
C
B
70
NOTE: All fan flow rates quoted are free air delivery.
60
90
Manrose CLASSIC DC SPECIALISED FANS
12/24V Extract-a-lite Models
Duct
Size
Model No.
Switching
Colour
Method
Performance
Order Code
100mm
BSL112W
Standard
18 l/s, 64m3/hr
FAN0625
White
3
100mm
BSL112G
Standard
Gold
18 l/s, 64m /hr
FAN0690
100mm
BSL112C
Standard
Chrome
18 l/s, 64m3/hr
FAN0691
3
100mm
BSL124W
Standard
White
18 l/s, 64m /hr
FAN0626
100mm
BSL124G
Standard
Gold
18 l/s, 64m3/hr
FAN0686
100mm
•
•
•
•
BSL124C
Standard
3
Chrome
18 l/s, 64m /hr
FAN0685
A compact extractor fan combined with an integral halogen light.
Designed for installation in galleys, showers and toilets, ideal for marine and other leisure applications.
Long life computer motor which will run continuously, only 2.8 watts.
Supported by a 2 year warranty.
Dimensions - DC Extract-a-lite
ACCESSORIES - Extract-a-lite Cowl
C
Duct Size
Description
Order Code
100mm
Extract-a-lite cowl
DCT1097
E B
A
• External cowl suitable for use in marine and non-marine applications
TECHNICAL DATA
F
D
Dimension information
Models
A
B
C
D
E
F
BSL112
140
90
52
12
98
38
BSL124
140
90
52
10
98
38
A
TECHNICAL SPECIFICATION
Performance - DC Extract-a-lite
Models
BSL112
BSL124
Power
12 VDC
24 VDC
Fan Performance
18 l/s, 64m³/hr
18 l/s, 64m³/hr
Fan Wattage
45W
45W
Maximum Pressure
125 Pa
125 Pa
Fan Speed
1400 RPM
1400 RPM
Sound Level
45 dB(A)
45 dB(A)
Max. Operating Temp
40°C
40°C
IP Rating
IPX4
IPX4
2
YEAR WARRANTY
Switching options
1. Standard Model - operates from remote switch (not supplied).
NOTE: All fan flow rates quoted are free air delivery.
61
FAN ACCESSORIES
Fan timer
Model No.
Description
Order Code
Time Air
7 Minute Fixed Timer (suits fans 20W-200W)
FAN0372
• A fixed fan timer that will automatically switch the appliance off after approximately 7 minutes.
Description
Order Code
Fully Adjustable Run-On Fan Timer
FAN2444
Time Air - Fan Timer
• Timing Switch 1 Sec to 90 Mins.
• Adjustable Run Timer & Start Delay.
Transformers
Fully adjustable
Run-On Fan Timer
Model No.
Description
Order Code
ACTO TE0060
Electronic Transformer 12VAC 50kHz
FAN2101
•
•
•
•
•
This transformer must only be used with 12V lighting installations.
Supports lamp wattages from 20W - 60W.
Overload & short circuit protection with self resetting.
Over temperature cut off.
Dimmable with trailing and leading edge dimmers.
Model No.
Description
Order Code
TM 50-2-07
SELV Isolating Transformer 12VAC
FAN2402
•
•
•
•
•
•
•
•
Electronic Transformer
SELV isolating transformer is required for all low voltage fan installations.
Can be used with low voltage 12V lighting.
Supports lamp wattages from 20W - 50W.
An iron core transformer.
Thermally stable and shatter-proof plastic casings.
Overload & short circuit protection with self resetting.
Over temperature cut off.
Dimmable with trailing and leading edge dimmers.
Humidistat Controller
Model No.
Description
Order Code
1360
Humidistat Controller
FAN0963
•
•
•
62
Designed to operate the fan when the relative humidity (RH) reaches
a preset level.
Fits a double pattress.
This unit is adjustable between 20 - 90% RH.
Humidistat Controller
FAN ACCESSORIES
ULTECON Thermostats
Model No.
Description
Order Code
TA01
Analogue Thermostat
FAN0153
TD01
Digital Thermostat
FAN0981
TD02
Digital 2 Speed Thermostat
FAN0982
TD03
Digital 3 Speed Thermostat
FAN0983
•
•
•
•
High quality, easy to use thermostats.
Dual output switching for both cooling and heating situations.
Electronic temperature sensor.
Included in Heat Trans systems.
TD03 Digital 3 Speed
Thermostat
Speed Controllers
Model No.
Description
Switching Method
Order Code
1348
For XF/XP/WF 230/300 Fans*
2 Spd + Reverse
FAN0155
1349
For XF/XP/WF 230/300 Fans*
Adjust + Reverse
FAN0156
1350
For any XF/XP/WF 230/300 Fans
Adjustable
FAN0157
PDL625F
General Purpose up to 500W
On-Off + Adjust
FAN2104
• A range of speed controllers with variable or 2 speed and reversible options.
• Models 1348-1350: Electrical load must be between 20 and 200 watts.
• FAN0154 - Single pattress mounting block for FAN0155/0156/0157.
PDL625F General
Purpose
*Not suitable for manual pull cord model fans.
ULTECON Speed Controller
Model No.
Description
Input
Output
Current Power
Order
Code
SPC05
Ultecon 5 Speed Fan Controller
1A
FAN1096
100W
• 5 speed fan selection - manual or external control.
• Enclosure can be wall mounted or free standing.
• On/Off switch.
Ulecon 5 Speed Fan Controller
Fan Mounting Brackets
Duct Size
Description
Order Code
100-200mm
Fan Mounting Bracket for 100 - 200mm
FAN0015
250-315mm
Fan Mounting Bracket for 250 - 315mm
FAN0016
• These adjustable fan mounting brackets, designed for use with the centrifugal fans.
• Supplied in pairs.
100-200mm Fan Mounting
Bracket
Thomas and Betts | www.manrose.com.au | [email protected]
63
AUSTRALIAN DUCT
STANDARDS
system then YOU ARE IN BREACH OF AS 4254, not
the manufacturer/duct assemblers.
We strive to provide the best possible flexible duct
at a competitive and fair price, that complies to all
necessary Standards.
Ducting that does not comply to AS 4254 may be used
on Reverse Cycle and Evaporative Systems except
in Victoria. The onus is on you to choose and use
compliant product.
Australian Standards (AS) 4254 & (AS) 4508
Most Commonly Asked Questions:
Q. What is AS 4254?
Q. What is AS 4508?
A. Australian Duct Fire Standard (AS) 4254.
This standard was developed to ensure public safety,
that the product tested will not support combustion and
will function as designed for its service life. All heating
systems in Australia ignited from a flame source and all
commercial class 2 to 9 buildings must FULLY COMPLY
with AS 4254. In Victoria all Ducting Installations must
be fire rated to AS 4254.
Q. How do I know if the duct passes AS 4254?
A. If a flexible duct passes AS 4254 it has been tested
to and passed eleven difficult tests. Ensure the product in
the test has been tested in its composite form, just the
way you buy it, i.e. duct core, insulation blanket and
outer jacket.
Each test should state product name and its componentry
make-up. If you cannot be supplied test reports to cover
each of the eleven tests or there is a reluctance from
duct manufacturers/duct assemblers to produce any or
all of these reports it is likely that the duct DOES NOT
comply to AS 4254.
Manufacturers/duct assemblers are under no obligation
to produce AS 4254 compliant product. If you install
flexible duct that does not comply, on a gas fired heating
A. Australian insulation Standard (AS) 4508.
Due to poor quality insulation being used on ducting,
AS 4508 was developed to create minimum acceptable
thermal values for ducting, helping to reduce the
greenhouse effect and lower running costs.
This standard specifies how insulation on the ducting
must be tested so an overall thermal or “R” value can
be achieved consistently throughout all the duct in
the system.
Q. How do I know if the insulation meets the requirements
of AS 4508?
A. Ask to see the test report from your duct manufacturer
/duct assembler that shows that the insulation had
been tested to and complies with AS 4508. To achieve a
thermal rating of R0.6 you must use a minimum of 250 g/
m² polyfibre insulation at 40mm thick.
To achieve an R1.0 you must use a minimum of 450
gram/square metre polyfibre insulation at 70mm thick.
Fibreglass thermal values remain the same as they have
for years, 25mm=R0.6 and 40mm=R1.0.
There will be variations depending on the manufacturer
of the insulation but in general the above rules apply.
Compliance to AS/NZ 1530 Part 3
AS/NZS 1530 Part 3
Requirements are:
This is the Australian standard 1530, method for fire
tests on building materials components and structures.
Internal Surface: Spread of flame not >0
Smoke Developed not >3
External Surface: Spread of flame not >7
Smoke developed not >5
“Simultaneous determination of ignitability, flame
propagation, heat release and smoke release”
AS 4254 comprises of the tests listed below:
(AS) 1530 part 3 - radiant burn test
Underwriters Laboratories
64
(U.L) 181 part 9 - flaming burn test
(U.L) 181 part 14 - static load test
(U.L) 181 part 11 - mould growth test (U.L) 181 part 15 - impact test
(U.L) 181 part 12.2 - low temperature test (U.L) 181 part 17 - positive & negative pressure test
(U.L) 181 part 12.3 - high temperature test (U.L) 181 part 18 - collapse test
(U.L) 181 part 13 - puncture test (U.L) 181 part 19 - tension test
DUCTING INSTALLATION & USAGE
The layout of flexible duct, the number of bends, the sharpness of the bend and the amount of sag allowed
between support joints will have serious effects on system performance due to the increased resistance to airflow
each introduces.
Use the minimum length of flexible duct to make connections. It is not recommended that excess length of ducts be
installed to allow for possible future relocations of air terminal devices.
Avoid installation where exposure to direct sunlight can occur e.g: skylight. Grilles and diffusers need to be supported
independently of the flexible duct.
Repair torn or damaged vapour barrier/jacket with duct tape listed and labelled to Standard AS4254. If internal core is
penetrated, replace flexible duct or treat as a join.
Right Setup
Install duct fully extended, do not install in the
compressed state or use excess lengths.
This will noticeably increase friction losses.
Wrong Setup
Avoid bending ducts across sharp corners or
incidental contact with metal fixtures, pipes
or conduits.
Flexible ducts shall be installed with a bend
radius to duct diameter ratio in accordance
with the following info on the next page.
Thomas and Betts | www.manrose.com.au | [email protected]
65
DUCTING INSTALLATION & USAGE
Duct velocity R/D ratio centerline
radius to duct diameter:
Up to 5m/s x 0.6
5m/s x 1.0
Above 8m/s x 1.5
e.g. Assuming duct velocity of 8m/s
Steam Pipes
Wrong Setup
Do not install near hot equipment (e.g. heaters
boilers, steam pipes etc.) that is above the
recommended flexible duct use temperature.
66
AIR DUCTS
01
Non-metallic with Plain Ends.
After desired length is determined, cut completely
around and through duct with knife or scissors.
Cut wire with wire cutters.
Fold back duct jacket and insulation.
02
Slide at least 1” (25mm) of core over the fitting up
to the bead. Seal the core to collar with at least
two wraps of duct tape.
Secure connection with cable ties placed over the
core and duct tape.
03
Pull jacket and insulation back over core.
Tape jacket with at least 2 wraps of duct tape
ensuring end of the outer jacket is secured to the
spigot. Cable ties may be used in place of or
in combination with the duct tape.
Thomas and Betts | www.manrose.com.au | [email protected]
67
JOINS
01
Fold back duct jacket and insulation from core.
Butt two cores together on a 4” (100mm) length
metal sleeve or polymer sleeve.
02
03
Tape cores together with at least 2 wraps of
duct tape. Connection can be secured with 2
cable ties placed over the taped core ends.
Pull jacket and insulation back over cores.
Tape jackets together with at least 2 wraps of
duct tape.
68
SUPPORTING FLEXIBLE DUCT
01
Flexible duct shall be supported at intervals, no greater
distance than 1.5m. Maximum permissible sag is 60mm
per metre of spacing between supports.
A connection to rigid duct or equipment shall be considered
a support joint.
SAG 60mm
Long horizontal duct runs with sharp bends shall have
additional supports before and after the bend approximately
one duct diameter from the centreline of the bend.
Recommend Hanging Straps DCT0808.
02
Hanger or saddle material in contact with the flexible duct
shall be of sufficient width to prevent any restriction of
the internal diameter of the duct when the weight of the
supported section rests on the hanger or saddle material.
In no case will the material contacting the flexible duct be
less than 40mm wide.
40mm min
40mm
Wire
03
Factory installed suspension systems integral to the
flexible duct is an acceptable hanging method.
Thomas and Betts | www.manrose.com.au | [email protected]
69
SUPPORTING
FLEXIBLE DUCT
Flexible ducts may rest on ceiling joists or truss
supports. Maximum spacing between supports
shall not exceed 1.5m.
Ceiling Joist
(1.8m) Max
Vertically installed duct shall be stabilised
by support straps at a max of 1.8m.
Support the duct between a metal connection and
bend by allowing the duct to extend straight for
100mm before making the bend.
This will avoid possible damage of the flexible
duct by the edge of the metal collar.
NOTE: Upon completion of installation, please
test in accordance with 2.8.2 of standard
AS4254.
NOTE: factory-made air ducts may not be
used for vertical risers in air duct systems
serving more than two stories.
70
FLEXIBLE DUCTING
Flexible
Ducting
Friction
FRICTION
LOSS
GRAPH Loss Graph
Technical Data
Flexible Ducting Friction Loss Graph
Technical Data
3/h
3/h
Air
Volume mm
AirVolume
Air Volume m3/h (m3/h 3.6 = l/s)
3/h / 3.6 = l/s)
3/h
(m(m
/ 3.6 = l/s)
(m3/h / 3.6 = l/s)
Air Volume m3/h
Diameter of Duct in mm
Flexible Ducting Friction Loss Graph
Friction Loss (Pa per metre)
40
40
metre)
Loss (Pa
Friction
FrictionLoss
(Paperper
metre)
0
Technical Data
Friction Loss (Paper metre)
Fax: (09) 259 1661 • Email: [email protected] • Website: www.securimax.co.nz
Fax: (09) 259 1661 • Email: [email protected] • Website: www.securimax.co.nz
Thomas and Betts | www.manrose.com.au | [email protected]
Fax: (09) 259 1661 • Email: [email protected] • Website: www.securimax.co.nz
71
ALUDUCT/COMFLEX FLEXIBLE DUCTING
Diameter
(mm)
Length
(m)
MANROSE
ALUDUCT
COMFLEX
NUDE
COMFLEX
INSULATED
Order Code
Order Code
Order Code
100
1
3
6
DCT0357
DCT0328
125
1
3
6
DCT0358
DCT0329
150
1
3
6
DCT0359
DCT0330
200
3
6
250
3
6
DCT0367
DCT0409
Nude
DCT0368
DCT0410
DCT0369
DCT0411
DCT0088
DCT0399
DCT0331
DCT0377
DCT0412
DCT0089
DCT0343
DCT0332
DCT0370
DCT0413
DCT0400
DCT0344
300
3
6
DCT0380
DCT0414
DCT0401
DCT0402
350
3
6
DCT0415
DCT0416
DCT0403
DCT0404
400
3
6
DCT0417
DCT0418
DCT0405
DCT0406
•
•
•
•
•
•
Insulated
Fully complies to AS 1530 Pt3.
DUCT CORE: Aluminium foil laminated onto polyester film, permanently bonded onto
a corrosion resistant coated, spring steel wire helix.
DUCT SLEEVE: Fire retardant 75μm black low density polyethylene and UV stabilised.
DUCT INSULATION: AS4508 Polyester R0.6.
TEMPERATURE RANGE: Maximum: +80˚C, Minimum: -10˚C.
COLOUR: Silver with black sleeve.
Colour Code Label Guide: Ducting
Black
150mm (6”)
Blue
250mm (10”)
Red
350mm (14”)
Yellow
200mm (8”)
White
300mm (12”)
Grey
400mm (16”)
Note
All 1 metre lengths are packed in bags with header cards, 3 metre aluduct
duct is supplied boxed and all other items are supplied in colour coded bags.
No glued/adhesive duct should be installed in a compressed or ovalised
state for fear of long term failure. Products with the “order code” shown
are generally ex. stock lines - other products are available to order.
72
Should you have an ongoing requirement for an item that is not a standard
stock line - PLEASE discuss with us and we will review stocking the item
for you.
UNILOK
FR1 Acoustic Ducting
INSULATED
R0.6
INSULATED
R1.0
Order Code
Order Code
Diameter
(mm)
Length
(m)
100
3
6
DCT1216
DCT1268
125
3
6
DCT1164
DCT1224
DCT1176
150
3
6
DCT0633
DCT0634
DCT0833
DCT0834
200
3
6
DCT0635
DCT0636
DCT0835
DCT0836
Acoustic Insulated R0.6 (40mm)
UNILOK FR1 Acoustic Ducting is a flexible duct manufactured “tough” & “whisper quiet” for consumer & installer peace
of mind. Unlike other types of flexible duct, UNILOK FR1 has an outer steel rib that ensures the products integrity, and
correct diameter, even in the tightest bends. Due to its steel rib, it is not prone to glue failure or fatigue (sagging or
ovalisation) from vibration with age like plastic ribbed or non-ribbed glued duct.
•
•
•
•
•
•
•
•
Fully complies to AS1530 Pt3.
Designed for low noise air transfer.
Fully flexible same mechanical construction as standard Unilok ducting.
DUCT CORE: A UV resilient fire retardant 100μm black low density polyethylene perforated
material mechanically locked into an outer metal helix with a copper coated spring steel wire.
DUCT SLEEVE: Fire retardant 75μm black low density polyethylene and UV stabilised.
DUCT INSULATION R0.6: AS4508 Polyester R0.6.
DUCT INSULATION R1.0: AS4508 Polyester R1.0.
TEMPERATURE RANGE: Maximum: +80˚C, Minimum: -10˚C.
Insertion Loss, dB Octive Band Centre Frequency
Sample
125
250
500
1000
2000
4000
8000
150mm UNILOK FR1 R0.6 AI
35.5
39.2
36.0
30.3
29.8
31.5
22.5
300mm UNILOK FR1 R0.6 AI
33.3
35.9
27.3
31.0
28.1
17.0
12.2
400mm UNILOK FR1 R0.6 AI
36.1
30.0
20.6
27.2
26.0
12.7
10.5
Colour Code Label Guide: Ducting
Black
150mm (6”)
Yellow
200mm (8”)
Note
1. Products with the “order code” shown are generally ex. stock lines - other products are available to order
2. Should you have an ongoing requirement for an item that is not a standard stock line – PLEASE discuss with us and we will review stocking the item for you.
Thomas and Betts | www.manrose.com.au | [email protected]
73
Manrose PVC
Flexible Ducting
Diameter
(mm)
Length
(m)
Pack
Order Code
100
1
3
Header Carded
Boxed
DCT0936
DCT0336
125
1
4
Header Carded
Boxed
DCT0937
DCT0337
150
1
5
Header Carded
Boxed
DCT0938
DCT0338
150mm PVC Flexible Ducting
P.V.C Flexible Duct is a product that is extremely versatile in the ventilation industry.
It doesn’t rot, is non-collapsing, is fire resistant, has an operating temperature of
+6° to +50° and is available in a range of sizes from 100mm to 150mm.
•
•
•
•
•
•
•
Fully complies to AS1530 Building code.
DUCT CORE: Spiral wire reinforced PVC film construction.
Non-collapsing/non-rotting.
Vapour-proof.
Fire retardant.
TEMPERATURE RANGE: Maximum: +50˚C : Minimum: 6˚C.
COLOUR: White PVC.
SEMIDUCT Semi Rigid
Ducting
Diameter (mm)
Length (m)
Pack
Order Code
100
1.5
3
Boxed
Loose
DCT0333
DCT0114
125
1.5
3
Boxed
Loose
DCT0334
DCT0115
150
1.5
3
Boxed
Loose
DCT0335
DCT0116
200
3
Loose
DCT0117
250
3
Loose
DCT0118
300
3
Loose
DCT0119
350
3
Loose
DCT0120
400
3
Loose
DCT0477
Semiduct Semi Rigid Ducting
SEMIDUCT is also known as semi-rigid aluminium ducting is a lightweight, flexible but strong corrugated aluminium
duct. It is spiral wound with a unique interlocked and knotted continuous seam. It is self supporting over longer
lengths and generally only needs fittings or mechanics at each end for support.
•
•
•
•
•
74
Fully complies to the Building Code of Australia.
DUCT CORE: Pure aluminium spiral wound with a unique interlocked and knurled continuous seam.
Holds shape, self supporting.
TEMPERATURE RANGE: Maximum: +250°C, Minimum: -30°C.
COLOUR: Silver.
Manrose
SOLID TUBE
Solid Tube - Rigid Steel
Diameter Length
(mm)
(m)
Finish
Order Code
100
0.9
Galvanised
DCT0151
100
0.9
White
DCT0145
125
0.9
Galvanised
DCT0152
125
0.9
White
DCT0146
125
1.2
Galvanised
DCT0953
150
0.9
Galvanised
DCT0153
150
0.9
White
DCT0147
150
1.2
Galvanised
DCT0954
Acoustic Insulated R0.6 (40mm)
Solid Tube - White Plastic
Diameter
(mm)
Length
(m)
Finish
Order Code
100
0.9
PVC
DCT1424
125
0.9
PVC
DCT1425
150
0.9
PVC
DCT1426
Manrose Low Profile Ducting
Flat Channel
Dimension
(mm)
Equivalent
Size (mm)
Length
(m)
Order Code
110 x 54
100
1.5
DCT0013
204 x 60
125
1.5
DCT0519
220 x 90
150
1.5
DCT1443
300 x 25
100
1.5
DCT1460
Low profile ducting enables it to be concealed when
installed along the top of wall units. It can also be fitted in
ceiling voids and cavity walls, providing versatility whilst
remaining unobtrusive. All Manrose system parts and
channels are made from flame-retardant material.
Four Low Profile System Sizes
110mm x 54mm:
Suitable for applications requiring low extraction rates,
such as ventilation of domestic bathrooms and toilets.
With a 5940mm2 cross-section it provides efficient
ducting for short, straight runs connecting to a 100mm
round spigot.
204 x 60 Low Profile Ducting
Flat channel
204mm x 60mm:
Suitable for ducting of kitchen cooker hoods with 100,
125 or 150mm round exhaust spigots. The flat channel
cross section of 12240mm2 increases efficiency.
High Performance 220mm x 90mm:
Suitable for applications requiring high performance
extraction or supply. The flat channel cross section of
19800mm2 makes it highly efficient and higher extraction
rates are achieved.
Flat Ducting 300mm x 25mm:
Suitable for applications where space is very limited.
Thomas and Betts | www.manrose.com.au | [email protected]
75
Manrose LOW PROFILE
DUCT FITTINGS
Low Profile Connectors
Horizontal 90° Bends
Vertical 90° Bends
Dimension
(mm)
Order
Code
Dimension
(mm)
Order
Code
Dimension
(mm)
Order
Code
110 x 54
DCT0014
110 x 54
DCT0125
110 x 54
DCT0126
204 x 60
DCT0520
204 x 60
DCT0524
204 x 60
DCT0525
220 x 90
DCT1442
220 x 90
DCT1448
220 x 90
DCT1447
300 x 25
DCT1459
300 x 25
DCT2097
300 x 25
DCT2099
Horizontal 45° Bend
Vertical 45° Bend
Dimension
(mm)
Order
Code
Dimension
(mm)
Order
Code
300 x 25
DCT2098
300 x 25
DCT1455
Short Adapter
Rectangular: Round
Adapters Rectangular:
Round
Horizontal T-Piece
Connectors
Dimension
(mm)
Order
Code
110 x 54
DCT1479
204 x 60
DCT1114
Flat Channel
Reducers
Dimension
(mm)
Order
Code
Dimension
(mm)
Order
Code
Dimension
(mm)
Order
Code
110 x 54 : 100
DCT0127 (f)
110 x 54 : 100
DCT1482
110 x 54:204 x 60
DCT0136
110 x 54 : 100
DCT0131 (m)
204 x 60 : 125
DCT0526
204 x 60:220 x 90
DCT1452
220 x 90 : 150
DCT1446
300 x 25:204 x 60
DCT1456
300 x 25 : 100
DCT1461
(m) = Male
(f) = Female
76
Designed to fit 204 x 60mm
flat channel or airbrick.
Elbow Bends 100mm
Elbow Bends 125mm
Elbow Bends 150mm
Dimension
(mm)
Order
Code
Dimension
(mm)
Order
Code
Dimension
(mm)
Order
Code
110 x 54
DCT0124 (m)
204 x 60
DCT0522
204 x 60
DCT0523
110 x 54
DCT0015 (f)
220 x 90
DCT1440*
220 x 90
DCT1441*
204 x 60
DCT0521
300 x 25
DCT2096
220 x 90
DCT1444
300 x 25
DCT2095
*Rotating offset spigot
*Rotating offset spigot
(m) = Male (f) = Female
Horizontal Bend
Adjustable
Horizontal Airbrick
Insert
Vertical Airbrick
Insert
Dimension
(mm)
Order
Code
Dimension
(mm)
Order
Code
Dimension
(mm)
Order
Code
204 x 60
DCT1480
204 x 60
DCT0137
204 x 60
DCT1414
Double Airbrick
Dimension
(mm)
Order
Code
232 x 138
DCT1450
Duct connection requires the
following Reducer or Connector:
110 x 54: requires: DCT0136
204 x 60: requires: DCT0520
Comes complete with duct
connector DCT0520.
Double Airbrick
Adaptor
Double Airbrick
Reducer
Dimension
(mm)
Order
Code
Dimension
(mm)
Order
Code
220 x 90:232 x 138
DCT1451
235 x 140
DCT1453
Thomas and Betts | www.manrose.com.au | [email protected]
77
Manrose LOW PROFILE
DUCT FITTINGS
Wall/Ceiling Plates
Rectangular
Wall/Ceiling Plates
Round
External Tube Grille
Dimension
(mm)
Order
Code
Dimension
(mm)
Order
Code
Diameter
(mm)
Order
Code
155 x 155 : 104 ø
DCT0148
155 x 155 : 110 x 55
DCT0016
100
DCT2206
170 x 170 : 130 ø
DCT0149
264 x 118 : 206 x 60
DCT0528
200 x 200 : 160 ø
DCT0150
A
External Louvred
Grilles
Designed to fit directly into round
solid tube, for systems ducted
straight through an external wall.
B
Flat Channel Clips
*2 clips are required to secure ducting.
Diameter
(mm)
Order
Code
Dimension
(mm)
Order
Code
100
DCT2200
110 x 54 (A)
DCT0134
125
DCT2201
204 x 60 (A)
DCT0527
150
DCT2202
220 x 90 (B)
DCT1445*
300 x 25 (B)
DCT1458*
Manrose In-Line
Backdraught Shutters
PVC
METAL
Duct Size (mm)
Order Code
Order Code
100
FAN0213
125
DCT0036
150
DCT0511
200
78
DCT2092
150mm PVC In-Line
Backdraught Shutter
BRANCH TAKE OFF
(B.T.O)
POLY
INSULATED
Duct Size (mm)
Order Code Order Code
100-100-100
DCT1439
125-125-125
DCT1501
150-150-150
DCT0091
DCT0875
200-150-150
DCT0719
DCT0876
200-200-150
DCT0460
DCT0877
200-200-200
DCT0461
DCT0878
200-200-200 Branch Take Off
•
•
•
•
•
•
Manufactured from HDPE.
UV stabilised, Heavy duty, robust.
Smooth internal lines, no sharp edges.
Positive lock duct tabs.
Insulation meets AS 1530 part 3.
Insulation material LDPE, thickness 5mm.
REDUCERS
PVC
Duct Size (mm)
Order Code
125-100
DCT2067
150-100
DCT2122
150-125
DCT2066
PVC Plastic
Duct Joiners/Spigots
PVC
METAL
LONG
METAL
SHORT
METAL PLATE
SPIGOTS
Duct Size
(mm)
Order Code
Order
Code
Order
Code
Order Code
100
DCT0159
125
Metal Long
PVC Plastic
Metal Short
Metal Plate Spigots
DCT0037
150
DCT0723
DCT0059
DCT0935
200
DCT0724
DCT0071
DCT0939
250
DCT0725
DCT0339
DCT0940
Note
1. Products with the “order code” showing are generally ex. stock lines - other products are available to order.
2. Combinations of sizes which are not ex. stock can be made up using
a suitable body and the relevant reducers and fitting joiners poly.
3. Nude combination fittings will be supplied in component form.
We do NOT assemble.
4. Insulated versions may not be ex-stock but will generally be available within 2-3 days of ordering.
5. Should you have an ongoing requirement for an item that is not a standard stock line – PLEASE discuss with us and we will review stocking the item for you.
Thomas and Betts | www.manrose.com.au | [email protected]
79
Manrose Wall/Ceiling Grilles
Fixed LOUVRE
Duct Size (mm)
Colour
Order Code
100
White
DCT0025
100
Grey
DCT0024
100
Terracotta
DCT0026
125
White
DCT0041
125
Grey
DCT0039
125
Terracotta
DCT0040
150
White
DCT0063
150
Grey
DCT0062
150
Terracotta
DCT0064
200
White
DCT0340
230/250
White
DCT0073
300
White
DCT1979
150mm Wall/Ceiling Grille
Fixed Louvre White
• Standard grille with some weather protection.
• Removable insert for easy cleaning.
Manrose Wall/Ceiling Grilles
EGGCRATE
Duct Size (mm)
Colour
Order Code
100
White
DCT0375
125
White
DCT0472
150
White
DCT0473
150mm Wall/Ceiling Grille
Eggcrate White
• Improved air-flow characteristics.
• Removable insert for easy cleaning.
DIMENSION INFORMATION
Grille Description
Duct Size
(mm)
Face Size
(mm)
Spigot Diameter
(mm)
Spigot Length
(mm)
Cut-Out
Size (mm)
Fixed Louvre Grille
100
140 x 140
100
35
105
Fixed Louvre Grille
125
162 x 162
122
25
127
Fixed Louvre Grille
150
174 x 174
152
32
157
Fixed Louvre Grille
200
285 x 285
199
67
240
Fixed Louvre Grille
230/250
285 x 285
230
29
240
Fixed Louvre Grille
300
350 x 350
285
50
295
Eggcrate Grille
100
140 x 140
100
34
105
Eggcrate Grille
125
162 x 162
122
24
127
Eggcrate Grille
150
175 x 175
152
34
157
80
Manrose DESIGNER Wall Grilles
STAINLESS Gravity
Duct Size (mm)
Colour
Order Code
100
Stainless Steel
DCT2145
125
Stainless Steel
DCT2146
150
Stainless Steel
DCT2147
Manrose Wall Grilles
PLASTIC Gravity
• High quality designer
stainless steel finish.
• Stainless Steel Grade 304.
Duct Size (mm)
Colour
Order Code
100
White
DCT0029
100
Grey
DCT0028
100
Terracotta
DCT0027
125
White
DCT0044
125
Grey
DCT0042
125
Terracotta
DCT0043
150
White
DCT0066
150
Grey
DCT0061
150
Terracotta
DCT0065
230/250
White
DCT2204
300
White
DCT1981
• Prevents back draughts
& weather penetration.
DIMENSION INFORMATION
Grille Description
Duct Size
(mm)
Face Size
(mm)
Spigot
Diameter
(mm)
Spigot
Length
(mm)
Cut-Out
Size
(mm)
Designer Gravity Grille
100
150 x 150
97
52
115
Designer Gravity Grille
125
180 x 180
120
52
140
Designer Gravity Grille
150
180 x 180
145
62
160
Standard Gravity Grille
100
140 x 140
100
35
105
Standard Gravity Grille
125
162 x 162
122
25
127
Standard Gravity Grille
150
174 x 174
152
32
157
Standard Gravity Grille
230/250
285 x 285
230
29
240
Standard Gravity Grille
300
350 x 350
285
50
295
The Designer Gravity Grille requires a minimum pressure to open.
• 20Pa - 100mm (DCT2145).
• 30Pa - 125mm (DCT2146).
• 30Pa - 150mm (DCT2147).
Thomas and Betts | www.manrose.com.au | [email protected]
81
Manrose Wall/Ceiling Grilles
Low Profile
Duct Size (mm)
Description
Colour
Order Code
100
Circular
White
DCT1089
100
Square
White
DCT2223
125
Circular
White
DCT1090
125
Square
White
DCT2224
150
Circular
White
DCT1067
150
Square
White
DCT2225
•
•
•
•
•
150mm Low Profile
Wall/Ceiling Grille
Low Profile eggcrate design improves airflow in extraction applications.
Twist lock fascia for easy cleaning.
Gib fixing clips included.
Longer spigot for easy duct connection.
Satin Silver & Chrome fascias available.
ACCESSORIES
Duct Size (mm)
Description
Colour
Order Code
125
Circular Fascia Satin Silver
FAN2069
125
Square Fascia Satin Silver
FAN2068
125
Circular Fascia Chrome
FAN0757
125
Square Fascia Chrome
FAN0755
125
Circular Fascia White
FAN0748
125
Square Fascia White
FAN0747
150
Circular Fascia Satin Silver
FAN2070
150
Square Fascia Satin Silver
FAN2071
150
Circular Fascia Chrome
FAN0613
150
Square Fascia Chrome
FAN0598
150
Circular Fascia White
FAN0750
150
Square Fascia White
FAN0749
125
Spigot
White
DCT1074
150
Spigot
White
FAN0656
150mm Low Profile Wall/Ceiling
Grille - Square/Circular
Accessories
DIMENSION INFORMATION
Duct
Size
(mm)
Face
Size
(mm)
Spigot
Diameter
(mm)
Spigot
Length
(mm)
Cut-Out
Size
(mm)
100
140
98
49
115
125
170
120
65
135
150
200
150
65
165
100
140 x 140 98
49
115
125
161 x 161 120
65
135
150
191 x 191 150
65
165
82
Manrose DESIGNER WALL/CEILING GRILLES
SQUARE
Duct Size
(mm)
Colour
Order Code
150
White
DCT2236
150
Silver
DCT2237
• High quality designer finish available in either white or brushed aluminium silver.
• Designed for bathroom extraction that blends into any decor.
Designer Wall/Ceiling Grilles
DIMENSION INFORMATION
Duct Size Face Size Spigot Diameter
(mm)
(mm)
(mm)
Spigot Length Cut-Out
(mm)
Size (mm)
150
191 x 191
150
65
157
150
191 x 191
150
65
157
Manrose WALL/CEILING GRILLES
CIRCULAR
Duct Size
(mm)
Colour
Order Code
100
White
DCT2185
125
White
DCT2186
150
White
DCT2187
• Concentric circular grille designed for extraction.
150mm Circular Wall/Ceiling Grille
DIMENSION INFORMATION
Duct Size
(mm)
Face Size
(mm)
100
140
125
150
Spigot Diameter
(mm)
Spigot Length
(mm)
Cut-Out Size
(mm)
98
49
105
170
125
65
125
200
150
65
157
Thomas and Betts | www.manrose.com.au | [email protected]
83
Manrose DESIGNER Ceiling Diffuser
STAINLESS STEEL
Duct Size (mm)
Colour
Order Code
100
Stainless
DCT2139
125
Stainless
DCT2140
150
Stainless
DCT2141
• High quality designer stainless steel finish - grade 304, Designed for internal extraction where a quality finish is required.
Designer Ceiling Diffuser
DIMENSION INFORMATION
Duct Size
(mm)
Face Size
(mm)
Spigot Diameter
(mm)
Spigot Length Cut-Out Size
(mm)
(mm)
100
140
97
52
105
125
172
120
52
130
150
220
145
62
150
Manrose Flat Ceiling Diffuser
Low Profile
Duct Size (mm)
Colour
Order Code
150
White
DCT2208
• High quality designer finish.
• Designed to supply air into your home, by pushing the air along the ceiling and down the walls. Included in Simx Home Ventilation Systems.
DIMENSION INFORMATION
Duct Size
(mm)
Face Size
(mm)
Spigot Diameter
(mm)
Spigot Length
(mm)
Cut-Out Size
(mm)
150
220
148
80
210
84
Flat Ceiling Diffuser
Ceiling DIFFUSER
CONE CENTRE
Duct Size (mm)
Colour
Order Code
150
White
DCT1472
200
White
DCT1473
250
White
DCT1474
300
White
DCT1475
•
•
•
•
•
•
•
•
Manufactured from ABS plastic.
Designed for either supply or extract ventilation.
When used to supply, the air will be pushed down into the room.
These diffusers are used in heat transfer systems.
Spring loaded fixing clips.
Resistant to scratching and fading.
Positive lock duct tabs.
Adjustable screw in centre cone to ensure a balanced airflow.
200mm Ceiling Diffuser
DIMENSION INFORMATION
Duct Size
(mm)
Face Size Spigot
(mm)
Diameter (mm)
Spigot Length
(mm)
Cut-Out Size
(mm)
150
266
150
95
232
200
317
200
95
282
250
389
250
102
355
300
400
300
102
405
EGGCRATE ROUND DIFFUSER
Duct Size (mm)
Colour
Damper
Order Code
150
Ice White
-
DCT2594
200
Ice White
-
DCT2595
150
Ice White
included
DCT2608
200
Ice White
included
DCT2609
•
•
•
•
•
Manufactured from ABS plastic.
Designed for either supply or extract ventilation.
Spring loaded fixing clips.
Resistant to scratching and fading.
Positive lock duct tabs.
150mm Eggcrate
Round Diffuser
DIMENSION INFORMATION
Duct Size
(mm)
Face Size Spigot
(mm)
Diameter (mm)
Spigot Length
(mm)
Cut-Out Size
(mm)
150
240
150
95
215
200
290
200
95
260
Thomas and Betts | www.manrose.com.au | [email protected]
85
CEILING DIFFUSER
ECO Diffuser
Ceiling Diffusers
Duct Size (mm)
Colour
Order Code
100
White
DCT0020
ng system is an investment in your families personal comfort. As
125
White
DCT0174
e placed on the type of ancillary products as to the type of unit
150
White
DCT0058
200
White
DCT0068
s are manufactured from ABS (Acrylonitrile Butadiene Styrene)
• Manufactured from A.B.S plastic.
type of plastic
that is used
products
like
fridge
• Designed
for in
either
supply
ortelephones,
extract ventilation.
• Fixing flange included, screws required.
• Adjustable screw in centre cone.
outside flange gives an attractive and unobtrusive finish. It is the
200mm Ceiling
‘ECO’ Diffuser
s used on our other plastic diffusers. So when you purchase
DIMENSION INFORMATION
products, you get a job that is aesthetically pleasing throughout
st.
Cone Centres are designed to suit the reverse cycle systems. Cone Centres
allow adjustable control of the airflow by moving the centre up or down.
This is achieved by a screwing technique. Clockwise decreases and shallows
Unijet
Cross Section
the airflow while
anti-clockwise
increases and deepens the airflow.
ed not to just
ke other
Duct Size
Face Size
(mm)
Spigot Diameter Spigot Length
(mm)
(mm)
Cut-Out Size
(mm)
100
149
99
47
98
125
169
125
47
123
et disperses(mm)
because it’s
gles.
mperature
150
186
148
50
148
200
235
198
50
198
Cone Centre Cross Section
Cone Centre Cross Section
d to suit the
ne Centres
f the airflow
r down. This
technique.
shallows the
se increases
Shallow Airflow
Deep Airflow
poor quality remains long after the
a low price has been forgotten.
ty Ltd ABN 21 005 072 873
Heidelberg West
86Victoria Australia 3081
t Heidelberg Victoria 3081 Australia
1 (0)3 9458-3120 email [email protected]
& New Zealand
Manrose DESIGNER Weatherproof COWLS
STAINLESS COWLS
Duct Size (mm)
Colour
Order Code
100
Stainless Steel
DCT2151
125
Stainless Steel
DCT2152
150
Stainless Steel
DCT2153
• High quality designer stainless steel finish.
• Designed for use where adverse weather conditions are experienced.
• Manufactured from a Stainless Steel Grade 304.
150mm Weatherproof
Cowl
Manrose Weatherproof COWLS
PLASTIC COWLS
Duct Size (mm)
Colour
Order Code
100
White
DCT0018
100
Brown
DCT0019
125
White
DCT1030
150
White
DCT1031
150mm Weatherproof Plastic Cowl
• Used where adverse weather conditions are experienced.
• 150mm Cowl, now includes mesh as standard
DIMENSION INFORMATION
Grille Description
Duct
Size
(mm)
Face Size
(mm)
Spigot
Diameter
(mm)
Spigot
Length
(mm)
Cut-Out
Size
(mm)
Designer Weatherproof
100
150 x 150
97
52
115
Designer Weatherproof
125
180 x 180
120
52
140
Designer Weatherproof
150
180 x 180
145
62
160
Standard Weatherproof
100
140 x 140
99
35
115
Standard Weatherproof
125
175 x 175
124
27
140
Standard Weatherproof
150
175 x 175
152
35
165
The Designer Weatherproof Cowl requires a minimum pressure to open.
• 10Pa - 100mm (DCT2151).
• 10Pa - 125mm (DCT2152).
• 10Pa - 150mm (DCT2153).
Thomas and Betts | www.manrose.com.au | [email protected]
87
Manrose DESIGNER Weatherproof Dome
STAINLESS DOME Cowls
Duct Size (mm)
Colour
Order Code
100
Stainless Steel
DCT2157
125
Stainless Steel
DCT2158
150
Stainless Steel
DCT2159
•
•
•
•
•
High quality stainless steel dome cowl for a modern stylish look.
Designed for exhaust and supply ventilation.
Generally mounted on an external wall, however they can be mounted internally.
Manufactured from a Stainless Steel Grade 304.
Insect mesh included.
dimension information
Duct
Size
(mm)
Face
Size
(mm)
Spigot
Diameter
(mm)
Spigot
Length
(mm)
Cut-Out
Size
(mm)
Designer Dome Cowl
100
140
97
52
115
Designer Dome Cowl
125
180
120
52
140
Designer Dome Cowl
150
200
145
62
155
Grille Description
88
150mm Weatherproof Stainless Dome Cowl
Manrose Wall/Ceiling PLATE GRILLES
Fixed Louvre Vent
Plate Size (mm)
Colour
Order Code
245 x 80
White
DCT2194
245 x 80
Chrome
DCT2195
245 x 160
White
DCT2196
245 x 160
Chrome
DCT2197
245 x 245
White
DCT2198
245 x 245
Chrome
DCT2199
Wall/Ceiling Plate Grilles Fixed Louvre Vent
Adjustable Vent
Plate Size (mm)
Colour
Order Code
245 x 80
White
DCT2188
245 x 80
Chrome
DCT2189
245 x 160
White
DCT2190
245 x 160
Chrome
DCT2191
245 x 245
White
DCT2192
245 x 245
Chrome
DCT2193
•
•
•
•
Manufactured from PVC in either white or chrome.
Designed for use when make-up air is required.
Fixed Louvre provides maximum airflow.
Adjustable Vent can be fully closed off when not required.
Wall/Ceiling Plate Grilles Adjustable Vent
Manrose Wall/Ceiling PLATE GRILLES
PLATE FACE
Duct Size (mm)
Grille Type
Colour
Order Code
150
Fixed Louvre
White
DCT0352
150
Gravity Shutter White
DCT0353
230
Fixed Louvre
DCT0354
White
• For situations where no spigot is required.
Manrose Door GRILLE
Wall/Ceiling Plate Grilles Plate Face
Model No.
Description
Order Code
Door Vent
Internal Door Ventilator Grille
FAN0159
• This door grille allows make-up air into the room.
• Dimensions: 455mm (h) x 90mm (w) to fit door with depth of 33mm.
Thomas and Betts | www.manrose.com.au | [email protected]
89
Roof Cowls
Duct Size (mm)
Description
Order Code
150
General Purpose Cowl
DCT0708
150
Heavy Duty Cowl
DCT0709
150mm General Purpose Cowl
• General Purpose Cowl - Low profile.
• Low back pressure.
- Added exhaust aperture area and deep vent coverage.
- Recommended where high winds in exposed locations may drive rain into the vent.
- Also recommended for use in high airflow air intake systems to prevent rain being sucked into the system.
150mm Heavy Duty Cowl
DIMENSION INFORMATION (mm)
Models
A
B
DCT0708
275
125
DCT0709
275
140
Performance - DCT0708/DCT0709
DCT0708 and DCT0709
Pressure vs Volume
A
100
Pressure (Pa)
80
B
60
40
20
0
0
50
100
150
Volume (litre/sec)
90
A
200
250
B
Roof Cowl Kits
with Flashing & HDPE Tube
Duct Size (mm)
Description
Order Code
150
General Purpose Kit
DCT0172
150
Heavy Duty Cowl Kit
DCT0710
150
General Purpose Lead Flashing Kit
DCT1095
•
•
•
•
•
General purpose cowl included.
0.5m HDPE Tube included.
Flashing included (for metal based roofs).
All fittings supplied.
Optional lead Flashing available (extra cost).
150mm General Purpose Kit
Note: Lead Flashing (DCT0190) required for concrete tile roofs.
Plastic Reducers for HDPE Thru-Roof Tube (for thru-roof kits)
Metric Size (mm)
Description
Order Code
150:125
150:125 reducer
DCT2066
150:100
150:100 reducer
DCT2122
• Reducers fit to the bottom of HDPE tube to adapt to smaller duct diameters where required.
Manrose Angled Roof Cowl Kit
Duct Size (mm)
Description
Order Code
125
Angled Roof Kit
DCT2205
•
•
•
•
General purpose through roof kit for smaller applications.
110mm PVC pipe - suitable for 125mm flexible ducting.
To be mounted on tile roofs.
Kit includes - Cowl, 0.5m of tube & weathering slate included.
Angled Roof Kit
Thomas and Betts | www.manrose.com.au | [email protected]
91
Manrose rangehood ducting kits
•
•
•
There are three ducting options available, for the kitchen
rangehood. Through an adjacent wall, through the soffit (under the eave) or up through the roof.
Semi-Rigid ducting is used in our top of the range systems
to reduce the rangehood system noise and increase air flow performance.
Fully complies to AS/NZS 60335.2.80.
Thru Wall rangehood DUCTING Kits
Duct Size (mm)
Description
Order Code
125
Rear Vent - Gravity Grille
DCT1162
150
Top & Rear Vent Weatherproof Cowl
DCT2592
• For added weather protection use the weatherproof cowl
as included in DCT2592.
Soffit rangehood DUCTING Kits
Duct Size (mm)
Description
Order Code
150
Thru Soffit
DCT1161
150
Thru Soffit - Galv Tube
DCT1259
150
Thru Soffit - Semi Rigid
DCT2323
• All systems include 3 metres of Aluminium Duct.
• Galv Tube system also includes 900mm of Solid Tube.
Thru ROOF rangehood DUCTING Kits
Duct Size (mm)
Description
Order Code
150
Thru Roof - Iron
DCT2324
150
Thru Roof - Tiled
DCT2325
FLASHING
Iron Roof
92
Tiled Roof
Manrose Dryer Ducting Kit
Rear Vent Thru Wall
Duct Size (mm)
Order Code
100
DCT1263
Kit Includes:
•
•
•
•
•
3m Flexible aluminium Aluduct (rated -30°C to 150°C).
0.75m Flat channel duct.
2 x Rectangular to Round 90° elbow bends.
100mm white eggcrate grille.
All fixing and fittings.
Dryer Ducting Kit
Dryer Ducting features
•
•
•
This ducting kit is designed for inverted and wall mounted dryers.
Free standing dryers on the floor will require extra rectangular ducting and connector (Order Code: DCT0013 & DCT0014).
These ducting kits suit dryers with a 100mm outlet. The square to round elbow will fit snugly onto most 100mm dryer outlets.
Pro Series Extension Kit
Duct Size (mm)
Description
Order Code
150
Heat Trans Extension Kit
DCT2101
150
SimxHome Extension Kit
DCT2276
Kit Includes:
•
•
•
•
•
Designed to extend your home ventilation or heat transfer
systems to additional rooms.
1 x Y-Branch.
1 x 3 metres - 150mm Acoustic Insulated Ducting.
1 x Adjustable Circular Diffuser.
All fixing and fittings included.
Thomas and Betts | www.manrose.com.au | [email protected]
93
Manrose Accessories
insect mesh
Duct Size (mm)
Description
Order Code
100
For 100mm Grilles
DCT0371
125
For 125mm Grilles
DCT0208
150
For 150mm Grilles
DCT0207
250
For 200mm & 250mm Grilles
DCT0373
150
Bird Mesh
DCT2263
Insect Mesh Accessory
Duct Straps and Duct Tape
Duct Size (mm)
Description
Order Code
100mm
Ducting Strap
FAN0274
125mm
Ducting Strap
FAN0281
150mm
Ducting Strap
FAN0282
12mm x 3m
Hanging Strap
DCT2299
25mm x 50m
Hanging Strap
DCT0808
48mm x 5m
Duct Tape
DCT0173
48mm x 30m
Duct Tape
DCT0807
48mm x 60m
Duct Tape - *AS4254
DCT1132
Ducting Straps & Duct Tape
AS4254 Duct Tape
*AS4254 Duct tape DCT1132
- Temperature range -37°C - 127°C
Roof Flashings
Description
Order Code
Flashing Roof Flashing - fits 110-160mm
DCT0180
Tiledek Roof Flashing - For use on concrete
tile, clay tile and slate roofing
DCT0190
0.5m HDPE Tube 150mm
DCT0183
Stitching Screws (for roof fastening)
FAN0400
94
Roof Flashings
Heat Trans
Systems
HEAT TRANS uses excess heat to warm other areas of the home by transferring it from one room to multiple rooms.
Heat Trans is the professional brand in heat transfer systems and is the brand of choice for electrical contractors.
Leading the market for over 15 years, Heat Trans is at the forefront of product development and innovation and the only
heat transfer systems using acoustic insulated ducting and digital controllers.
How does Heat Trans work
01
02
03
Excess heat from your heat source will rise to
ceiling level where it is trapped. This excess heat
can reach temperatures of 30-35°C.
This excess heat can be effectively transferred to
other rooms using a high quality fan and acoustic
insulated ducting.
Air moves from the bedrooms back to the lounge
creating a natural recirculation of warm air throughout
the home. This will also make your home healthier
by helping to reduce mould and mildew.
MODELS
MODEL
Order Code
Heat Trans One Room Kit
FAN0325
Heat Trans Two Room Kit
FAN0337
Heat Trans Three Room Kit
FAN0338
Pro-Series One Outlet
Extension Kit
DCT2101
Heat Trans Summer-Vent
Extension Kit
DCT1481
Heat Trans Thru Wall Kit
FAN0005
Heat Trans systems utilise
excess heat throughout
the home and cost as little
as a light bulb to run.
Thomas and Betts | www.manrose.com.au | [email protected]
95
Heat Trans
Systems
One Room Kit
Outlet Size Description
150mm
Fan Speeds
Heat Trans One
Room Kit
Order Code
1
FAN0325
Kit includes:
•
•
•
•
•
•
1 x Ultecon Digital Thermostat Controller.
1 x 150mm High Performance Axial Flow Fan.
2 x 3 Metres - 150mm Acoustic Insulated Ducting.
1 x Circular Inlet Grille.
1 x Adjustable Circular Design Outlet Diffuser.
All Fittings and Fixings Included.
Two Room Kit
Outlet Size Description
150mm
Heat Trans
Two Room Kit
Fan Speeds Order Code
2
FAN0337
Kit includes:
•
•
•
•
•
•
•
1 x Ultecon Digital Thermostat/ Fan Speed Controller
1 x 150mm Multi-Speed High Performance Fan.
4 x 3 Metres - 150mm Acoustic Insulated Ducting.
1 x Branch Take-Off (Splitter).
1 x Circular Inlet Grille.
2 x Adjustable Circular Design Outlet Diffusers.
All Fittings and Fixings Included.
Three Room Kit
Outlet Size Description
150mm
Heat Trans Three
Room Kit
Fan Speeds
3
Order Code
FAN0338
Kit includes:
•
•
•
•
•
•
•
•
96
1 x Ultecon Digital Thermostat/ Fan Speed Controller.
1 x 200mm Multi-Speed High Performance Fan.
3 x 3 Metres - 150mm Acoustic Insulated Ducting.
2 x 3 Metres - 200mm Acoustic Insulated Ducting.
1 x Double Branch Take-Off (Three Way Splitter).
1 x Circular Inlet Grille.
3 x Adjustable Circular Design Outlet Diffusers.
All Fittings and Fixings Included.
Heat trans
Features
The Ultecon digital thermostat controller measures and displays the temperature of your lounge and lets you preset your
preferred room temperature.
When your lounge temperature exceeds your preferred room temperature the system will automatically start to transfer
the excess heat to other rooms in your home.
The 2 and 3 room systems also offer fan speed control, which allows you to set your preferred fan speed giving you
ultimate control over the volume of heated air being transferred.
Superior Fans
High quality multi-speed fans for optimum airflow ventilation in the home that cost as little as
a light bulb (between 70W and 120W) to run. These high quality fans have been specifically
selected to ensure correct airflow and pressure levels are achieved.
Whisper quiet
The unique acoustic insulated ducting reduces air transfer noise to a ‘whisper quiet’ level.
Better temperature retention is achieved, ensuring optimal heat transfer of excess warm air.
One Room Controller
Adjustable diffusers
Easily adjustable to allow balancing of the airflow into each room. Simply twist the centre
section of the diffuser to allow more or less air into each room. Or simply close any diffuser
when the room is not in use.
Optional extras
Two/Three Room
Controller
Summer feature
Introduce fresher cooler air into your home in summer with the Summer-Vent Extension
Kit, to enable year round use of your system.
With the inlet grille installed under your soffit, fresher cooler air is filtered using a high
efficiency F7 filter and is distributed throughout your home via your Heat Trans outlets.
The system is controlled via a standard wall switch which operates the motorised
damper to start drawing air from outside.
Note: When the summer feature is working the lounge warmed room inlet is switched
off via the damper and will not receive the cooled air directly from outside, however due
to air pressure a natural re-circulation occurs throughout the home.
Summer Feature Extension Kit
Extension kit
The Pro-Series One Outlet Extension Kit is designed to extend your standard three room
Heat Trans system so you can distribute warm air to an extra room within your home.
The extension kit gives you the flexibility to add additional outlet/s to your Heat Trans
system. By adding additional outlet/s to your system you are simply dividing the available
heated air amongst more rooms.
Note: All Heat Trans kits can be extended.
1 Room kits can be extended to a max length of 12 metres ( 6 metres supplied in kit).
2 Room kits can be extended to a max length of 21 metres (12 metres supplied in kit).
3 Room kits can be extended to a max length of 24 metres (15 metres supplied in kit).
Pro-Series One
Outlet Extension Kit
Thomas and Betts | www.manrose.com.au | [email protected]
97
Alpha-Numeric index
Order codes
DCT0013
75
DCT0126
76
DCT0358
72
DCT0525
76
DCT1161
92
DCT0014
76
DCT0127
76
DCT0359
72
DCT0526
76
DCT1162
92
DCT0015
77
DCT0131
76
DCT0360
40
DCT0527
78
DCT1164
73
DCT0016
78
DCT0134
78
DCT0362
40
DCT0528
78
DCT1169
40
DCT0018
87
DCT0136
76
DCT0366
40
DCT0633
73
DCT1171
40
DCT0019
87
DCT0137
77
DCT0367
72
DCT0634
73
DCT1176
73
DCT0020
86
DCT0145
75
DCT0368
72
DCT0635
73
DCT1216
73
DCT0024
80
DCT0146
75
DCT0369
72
DCT0636
73
DCT1224
73
DCT0025
80
DCT0147
75
DCT0370
72
DCT0708
90
DCT1259
92
DCT0026
80
DCT0148
78
DCT0371
94
DCT0709
90
DCT1263
93
DCT0027
81
DCT0149
78
DCT0373
94
DCT0710
91
DCT1268
73
DCT0028
81
DCT0150
78
DCT0375
80
DCT0719
79
DCT1414
77
DCT0029
81
DCT0151
75
DCT0377
72
DCT0723
79
DCT1424
75
DCT0036
78
DCT0152
75
DCT0380
72
DCT0724
79
DCT1425
75
DCT0037
79
DCT0153
75
DCT0399
72
DCT0725
79
DCT1426
75
DCT0039
80
DCT0159
79
DCT0400
72
DCT0807
94
DCT1439
79
DCT0040
80
DCT0172
91
DCT0401
72
DCT0808
94
DCT1440
77
DCT0041
80
DCT0173
94
DCT0402
72
DCT0833
73
DCT1441
77
DCT0042
81
DCT0174
86
DCT0403
72
DCT0834
73
DCT1442
76
DCT0043
81
DCT0180
94
DCT0404
72
DCT0835
73
DCT1443
75
DCT0044
81
DCT0183
94
DCT0405
72
DCT0836
73
DCT1444
77
DCT0058
86
DCT0189
56
DCT0406
72
DCT0875
79
DCT1445
78
DCT0059
79
DCT0190
94
DCT0409
72
DCT0876
79
DCT1446
76
DCT0061
81
DCT0207
94
DCT0410
72
DCT0877
79
DCT1447
76
DCT0062
80
DCT0208
94
DCT0411
72
DCT0878
79
DCT1448
76
DCT0063
80
DCT0328
72
DCT0412
72
DCT0935
79
DCT1450
77
DCT0064
80
DCT0329
72
DCT0413
72
DCT0936
74
DCT1451
77
DCT0065
81
DCT0330
72
DCT0414
72
DCT0937
74
DCT1452
76
DCT0066
81
DCT0331
72
DCT0415
72
DCT0938
74
DCT1453
77
DCT0068
86
DCT0332
72
DCT0416
72
DCT0939
79
DCT1455
76
DCT0071
79
DCT0333
74
DCT0417
72
DCT0940
79
DCT1456
76
DCT0073
80
DCT0334
74
DCT0418
72
DCT0953
75
DCT1458
78
DCT0088
72
DCT0335
74
DCT0460
79
DCT0954
75
DCT1459
76
DCT0089
72
DCT0336
74
DCT0461
79
DCT1030
87
DCT1460
75
DCT0091
79
DCT0337
74
DCT0472
80
DCT1031
87
DCT1461
76
DCT0114
74
DCT0338
74
DCT0473
80
DCT1067
82
DCT1472
85
DCT0115
74
DCT0339
79
DCT0477
74
DCT1074
82
DCT1473
85
DCT0116
74
DCT0340
80
DCT0511
78
DCT1076
82
DCT1474
85
DCT0117
74
DCT0343
72
DCT0519
75
DCT1089
82
DCT1475
85
DCT0118
74
DCT0344
72
DCT0520
76
DCT1090
82
DCT1479
76
DCT0119
74
DCT0352
89
DCT0521
77
DCT1095
91
DCT1480
77
DCT0120
74
DCT0353
89
DCT0522
77
DCT1097
61
DCT1481
95
DCT0124
77
DCT0354
89
DCT0523
77
DCT1114
76
DCT1482
76
DCT0125
76
DCT0357
72
DCT0524
76
DCT1132
94
DCT1501
79
98
Alpha-Numeric index
Order codes
DCT1519
38
DCT2196
89
FAN0055
24
FAN0282
94
FAN0519
28
DCT1520
38
DCT2197
89
FAN0060
46
FAN0325
95
FAN0520
28
DCT1521
38
DCT2198
89
FAN0061
46
FAN0325
96
FAN0521
28
DCT1522
38
DCT2199
89
FAN0064
36
FAN0326
48
FAN0529
56
DCT1979
80
DCT2200
78
FAN0065
36
FAN0327
48
FAN0530
56
DCT1981
81
DCT2201
78
FAN0071
14
FAN0328
36
FAN0531
56
DCT2066
79
DCT2202
78
FAN0072
14
FAN0329
36
FAN0532
56
DCT2066
91
DCT2204
81
FAN0074
14
FAN0330
50
FAN0533
56
DCT2067
79
DCT2205
91
FAN0075
14
FAN0337
95
FAN0534
56
DCT2092
78
DCT2206
78
FAN0080
24
FAN0337
96
FAN0535
56
DCT2095
77
DCT2208
84
FAN0082
24
FAN0338
95
FAN0589
12
DCT2096
77
DCT2223
82
FAN0083
24
FAN0338
96
FAN0590
12
DCT2097
76
DCT2224
82
FAN0085
44
FAN0346
16
FAN0591
12
DCT2098
76
DCT2225
82
FAN0090
46
FAN0348
16
FAN0594
12
DCT2099
76
DCT2236
83
FAN0091
46
FAN0355
26
FAN0595
12
DCT2101
93
DCT2237
83
FAN0101
36
FAN0357
50
FAN0596
12
DCT2101
95
DCT2263
94
FAN0102
36
FAN0358
50
FAN0598
12
DCT2120
40
DCT2276
93
FAN0107
26
FAN0360
50
FAN0598
22
DCT2121
40
DCT2299
94
FAN0109
26
FAN0361
50
FAN0598
82
DCT2122
79
DCT2323
92
FAN0110
26
FAN0372
62
FAN0604
12
DCT2122
91
DCT2324
92
FAN0119
14
FAN0374
16
FAN0605
12
DCT2139
84
DCT2325
92
FAN0120
14
FAN0397
60
FAN0606
12
DCT2140
84
DCT2592
92
FAN0121
14
FAN0400
94
FAN0609
12
DCT2141
84
DCT2594
85
FAN0122
14
FAN0405
46
FAN0610
12
DCT2145
81
DCT2595
85
FAN0123
14
FAN0406
46
FAN0611
12
DCT2146
81
DCT2608
85
FAN0124
14
FAN0409
24
FAN0613
12
DCT2147
81
DCT2609
85
FAN0126
14
FAN0410
24
FAN0613
22
DCT2151
87
FAN0005
95
FAN0127
14
FAN0411
24
FAN0613
82
DCT2152
87
FAN0012
46
FAN0135
24
FAN0412
60
FAN0614
22
DCT2153
87
FAN0013
46
FAN0136
24
FAN0413
60
FAN0615
22
DCT2157
88
FAN0015
63
FAN0137
24
FAN0420
40
FAN0616
34
DCT2158
88
FAN0016
63
FAN0138
24
FAN0431
38
FAN0617
34
DCT2159
88
FAN0017
36
FAN0140
24
FAN0431
40
FAN0618
34
DCT2185
83
FAN0018
36
FAN0141
24
FAN0438
40
FAN0619
34
DCT2186
83
FAN0021
26
FAN0146
28
FAN0452
26
FAN0620
22
DCT2187
83
FAN0038
20
FAN0148
28
FAN0455
16
FAN0621
22
DCT2188
89
FAN0041
20
FAN0153
63
FAN0467
50
FAN0623
22
DCT2189
89
FAN0042
20
FAN0155
63
FAN0481
28
FAN0625
61
DCT2190
89
FAN0044
14
FAN0156
63
FAN0482
28
FAN0626
61
DCT2191
89
FAN0046
14
FAN0157
63
FAN0499
20
FAN0644
82
DCT2192
89
FAN0047
14
FAN0159
89
FAN0501
20
FAN0656
82
DCT2193
89
FAN0048
14
FAN0213
78
FAN0504
20
FAN0685
61
DCT2194
89
FAN0053
24
FAN0274
94
FAN0505
20
FAN0686
61
DCT2195
89
FAN0054
24
FAN0281
94
FAN0518
28
FAN0690
61
Thomas and Betts | www.manrose.com.au | [email protected]
99
Alpha-Numeric index
Order codes
FAN0691
61
FAN1053
42
FAN2127
42
FAN0732
22
FAN1060
56
FAN2162
30
FAN0735
22
FAN1096
63
FAN2200
30
FAN0738
22
FAN2029
38
FAN2205
103
FAN0739
56
FAN2030
38
FAN2206
103
FAN0740
56
FAN2031
38
FAN2213
102
FAN0748
82
FAN2032
38
FAN2214
102
FAN0750
82
FAN2033
38
FAN2229
104
FAN0755
12
FAN2034
38
FAN2230
104
FAN0755
22
FAN2035
38
FAN2286
58
FAN0755
82
FAN2036
38
FAN2287
58
FAN0757
12
FAN2037
40
FAN2303
54
FAN0757
22
FAN2038
40
FAN2402
62
FAN0757
82
FAN2040
16
FAN2423
54
FAN0803
40
FAN2040
16
FAN2424
54
FAN0804
40
FAN2041
16
FAN2425
54
FAN0827
40
FAN2042
16
FAN2426
54
FAN0829
52
FAN2043
16
FAN2444
62
FAN0830
52
FAN2049
32
FAN2465
18
FAN0841
60
FAN2050
32
FAN2902
58
FAN0884
18
FAN2051
32
FAN2903
58
FAN0885
18
FAN2066
48
FAN4395
58
FAN0916
44
FAN2067
48
FAN4396
58
FAN0921
49
FAN2068
12
FAN4397
58
FAN0940
30
FAN2068
22
LHT0081
30
FAN0963
62
FAN2068
82
LHT0140
30
FAN0967
56
FAN2069
12
FAN0981
63
FAN2069
22
FAN0982
63
FAN2069
82
FAN0983
63
FAN2070
12
FAN0995
30
FAN2070
22
FAN0997
49
FAN2070
82
FAN1002
56
FAN2071
12
FAN1004
42
FAN2071
22
FAN1005
42
FAN2071
82
FAN1006
42
FAN2076
40
FAN1007
42
FAN2078
46
FAN1009
56
FAN2101
38
FAN1014
30
FAN2101
40
FAN1015
30
FAN2101
62
FAN1043
60
FAN2104
63
FAN1048
42
FAN2124
42
FAN1050
42
FAN2125
42
FAN1051
42
FAN2126
42
100
Energy Efficient
Ventilation Solutions
Lo-Carbon
Lo-Carbon fans from Vent-Axia offer up to 70%
energy savings by utilising market leading motor
technology, to help reduce your carbon footprint.
Lo-Carbon
Thomas & Betts are proud to be the distributor of the Vent-Axia
Lo-Carbon range of ventilation fans.
MANROSE offers an extensive range of extraction fans suitable for bathrooms, en-suites,
laundries and kitchens.
Vent-Axia Lo-Carbon long life motors last 5 times longer than
conventional AC motors.
The extended life of the Lo-Carbon fans is due to the use of a
new generation of high quality ball bearing motor.
These high quality ventilation fans are specifically designed for
bathrooms, extracting moisture laden air quietly & effectively.
Unit D3, 3-29 Birnie Avenue, Lidcombe NSW 2141
Western Australia
South Australia
Unit 2, 22 Hammond Rd Cockburn Central WA 6164
86A Richmond Rd Keswick SA 5035
Victoria
Queensland
2/13-15 Brough St Springvale VIC 3171
26 Turbo Drive Cooparoo QLD 4151
Tasmania
Newcastle
Electrical Agencies 4 Linear Court Moonah TAS 7009
Nick Webb Agencies Unit 5, 21 Babilla Close
Beresfield NSW 2322
National Support Centre
Phone: 1300 666 595
Fax: 1300 666 594
Email: [email protected]
Web: www.manrose.com.au
Energy Efficient
Ventilation Solutions
67%
en
savin ergy
g
The distributors of Manrose Ventilation fans are proud
to distribute the Vent-Axia Lo-Carbon range.
These fans offer up to 70% energy savings, utilising market leading motor technology, which lasts
considerably longer than conventional AC motors.
These high quality ventilation fans are specifically designed to extract moisture-laden air quietly
and efficiently. The Vent-Axia Lo-Carbon range includes solutions for wall, ceiling, window and roof
mounted applications.
With energy savings in mind these models operate efficiently at lower wattage levels, the Silhouette
LCS150 for example operates at 8.2W as opposed to a standard ceiling fan which operates at 25W,
a saving of 67%.
Lo-Carbon
VENT-AXIA LO CARBON vent-a-light fan
100 VENT-A-Light
Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to
70% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball
bearing motors. 100mm Lo Carbon axial in-line shower fan and light kit. Suitable for shower enclosures and
wet areas.
Models include 2 speeds selectable at installation to customise the fan to each application and come complete
with a neon to indicate operation.
• Low Power consumption - 70% energy savings.
• Complete with 3m flexible ducting, white grille
and light transformer.
• 1 of 2 speeds selectable at installation.
• High quality ball bearing motors.
• Modern aesthetics, includes blue neon “on light”.
• Fan IPX4 rated.
• 5 Year Warranty.
70%
sav energy
ing
s
Performance
Size
(mm)
Model No.
100
Vent-a-light B
100
Vent-a-light T
Extract Performance* Watts
Sound
(m3/hr)
(l/s)
(W)
dB(A)
@3m
Lo-Carbon Vent-a-Light
Standard
110
31
6.5 +35
23
FAN2229
Lo-Carbon Vent-a-Light
Timer
110
31
6.5 +35
23
FAN2230
Description
* 1 of 2 speeds selectable at installation
* Please note the energy savings only apply to the fan motor, there is still a 35W centre lamp.
Switching Options
1. Standard Model - operates from remote switch (not supplied).
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.
NOTE: All fan flow rates quoted are free air delivery.
Order Code
VENT-AXIA LO CARBON wall/ceiling mounted fans
Silhouette® 150
Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to
67% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball
bearing motors. With a slim profile of only 19mm, Silhouette blends in with the wall surface to provide an
unobtrusive installation. Silhouette can be ceiling or wall mounted and connected to an appropriate duct run
to exhaust outside.
Models include 2 speeds selectable at installation to customise the fan to each application and come complete
with a neon to indicate operation.
• 19mm stylish low profile grille.
• Low Power consumption - 67% energy savings.
• Downstream airflow guide vanes for improved
pressure development.
• 1 of 2 speeds selectable at installation.
• High quality ball bearing motors.
• Modern aesthetics, includes blue neon ‘on light’.
• Fan IPX4 rated.
• 5 Year Warranty.
67%
sav energy
ing
s
Performance
Extract Performance* Watts Sound
Size
(mm)
Model
No.
Description
150
LCS150B
150
LCS150T
(m3/hr)
(l/s)
(W)
dB(A)
@3m
Lo-Carbon Wall/Ceiling
Silhouette Standard
165
46
5
35
241
67
8.2
43
Lo-Carbon Wall/Ceiling
Silhouette Timer
165
46
5
35
241
67
8.2
43
Order Code
FAN2213
FAN2214
* 1 of 2 speeds selectable at installation
Wattage Comparison
Size (mm)
Model No.
Description
Wattage
150
XFLP150
Manrose Pro-Series Wall/Ceiling Fan
25W
150
LCS150
Vent-Axia Lo-Carbon Wall/Ceiling Fan
8.2W
Energy Savings
16.8W
67%
ENERGY SAVINGS
Switching Options
1. Standard Model - operates from remote switch (not supplied).
NOTE: All fan flow rates quoted are free air delivery.
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.
Thomas & Betts | www.manrose.com.au | [email protected]
VENT-AXIA LO CARBON wall/ceiling mounted fans
Silhouette® 100
Vent-Axia Lo-Carbon long life motors last considerably longer than conventional motors whilst delivering up to
63% energy savings. The extended life of Lo-Carbon fans is due to a new generation of high quality ball
bearing motors. With a slim profile of only 17mm, Silhouette blends in with the wall surface to provide an
unobtrusive installation. Silhouette can be ceiling or wall mounted and connected to an appropriate duct run
to exhaust outside.
Models include 2 speeds selectable at installation to customise the fan to each application and come
complete with a neon to indicate operation.
• 17mm stylish low profile grille.
• Low Power consumption - 63% energy savings.
• Downstream airflow guide vanes for improved
pressure development.
• 1 of 2 speeds selectable at installation.
• High quality ball bearing motors.
• Modern aesthetics, includes blue neon “on light”.
• Fan IPX4 rated.
• 5 Year Warranty.
63%
sav energy
ing
s
Performance
Extract Performance* Watts Sound
Size
(mm)
Model
No.
Description
100
LCS100B
100
LCS100T
(m3/hr)
(l/s)
(W)
dB(A)
@3m
Lo-Carbon Wall/Ceiling
Silhouette Standard
95
26
7.5
34
60
16
3.4
38
Lo-Carbon Wall/Ceiling
Silhouette Timer
95
26
7.5
34
60
16
3.4
38
Order Code
FAN2205
FAN2206
* 1 of 2 speeds selectable at installation
Wattage Comparison
Size (mm)
Model No.
Description
Wattage
100
XF100
Manrose Wall/Ceiling Fan
20W
100
LCS100
Vent-Axia Lo-Carbon Wall/Ceiling Fan
7.5W
Energy Savings
12.5W
63%
ENERGY SAVINGS
Switching Options
1. Standard Model - operates from remote switch (not supplied).
2. Timer Model - Fan operates from a switch, the fan continues to run
for a preset time after switching off - adjust able 1-20 minutes. Requires three wires: permanent phase, switched phase, neutral.
NOTE: All fan flow rates quoted are free air delivery.