0.3 High Accuracy Electronic Batch Controller
Transcription
0.3 High Accuracy Electronic Batch Controller
0.3 High Accuracy Electronic Batch Controller INDOOR 19’ Rack Version Outdoor EX-PROOF Version Designed for hydrocarbons measure, with high accuracy requirements: • Pipeline and custody transfer • Ship Tankers loading / unloading • Trucks & railcars loading 47 rue de Paris 94470 Boissy-Saint-Léger France - phone nb: +33 1 45 69 44 70 fax: +33 1 45 69 16 02 email: [email protected] website: www.alma-alma.fr 1/4 Indoor or on-site outdoor, that’s your choice… For any liquid hydrocarbon or chemicals measure application, the MicroCompt electronic batch controller allows you to choose the most adapted solution to your site and / or your process and to optimize your installation costs. The 19’ rack version for off-site control room or the ex-proof on-site version, the MicroCompt owns all the required characteristics to control any high accuracy metering set con one or two metering units each. Approved by Weight and Measures Authorities in the class 0.3 accuracy, the MicroCompt can control any type of metering unit: turbine flow meter, PD meter, mass flow meter, ultrasonic meter, etc… The MicroCompt carries out the acquisition of all influence parameters (temperature, pressure, density or standard density), performs the required measure corrections on the gross volume of product metered and determines the volume at any reference standard. Secured storage, MODBUS network communication for dynamic supervision and local process control command are fully completed as well as the overall functions offered the MicroCompt. SUPERVISION CONTROL / COMMAND Indoor version RS485 MODBUS Site Outdoor version 47 rue de Paris 94470 Boissy-Saint-Léger France - phone nb: +33 1 45 69 44 70 fax: +33 1 45 69 16 02 email: [email protected] website: www.alma-alma.fr 2/4 Typical Applications Indoor or Outdoor, the Microcompt Electronic Batch Controller allows to fulfill all metrological custody and terminal loading operations: Electronic display for turbine meters, PD meters Mass flow meters Measure of 2 simultaneous parallel metering units Measure correction for any product or any other influence parameters Volume conversion base Mass conversion In addition to basic metrological functions: Measure transactions Secure back-up MODBUS communication for dynamic supervision Control – command functions in order to drive remotely the metering set from control room Deliveries management functions: journal, automatic transfer notes / orders, different total counters etc … Sampler interface, additivation devices, blending, coloring agent, etc … EX–PROOF version, with local control or supervision remote control. This device is adapted to any factory skid integration (cabling and complete tests before on-site delivery) and to remote management far from control room thanks to local connection with all on-site sensors / actuators. Connection to central site lilted to a power supply single network and a network double pair communication cable. 47 rue de Paris 94470 Boissy-Saint-Léger France - phone nb: +33 1 45 69 44 70 fax: +33 1 45 69 16 02 email: [email protected] website: www.alma-alma.fr 3/4 Data Sheet Temperature Input Standard density Mass Input Pressure Input Network Communication Flow rate measuring and mirror measure channel Other Inputs Outputs Main Functions Complementary Functions Rack 19", 3U for standard casing 5 kg 300 x 230 x P210 mm 12,5 kg N° LNE-13624 rev1 - 2009/01/05 N° LNE-13624 rev1 - 2009/01/05 II 2(1) G Ex d[ia] IIB T6 220 VAC, 1A 220 VAC, 1A 2 inputs, dual channel, direct with 2H pulses transmitter with current active control – inductance coils – open collector - signal tension. Perturbation filtering, coherency control 1 input PT100 3 wires per metering unit. Accuracy better than 0,3°C 1 input high frequency for direct control MV transmitter 1 analogical input 4-20 mA for MV transmitter 1 analogical input 4-20mA per measure range RS485 channel, 2 cables, MODBUS protocol for complete dynamic supervision and control, control - command process. Double channels pulses through per measure range, open collector Analogical input 4-20 mA (flow range) 2 additional metering channel (additivation, blending, ) 3 analogical inputs 0-100mA (gas/liquid detector… 14 ON/OFF circuit/Open collector, security devices, plc,… 6 X 24 Vcc outputs, automatisation process 8 X 220 VAC output, valves direct control, actuators … Meter correction, volume conversion at reference state, mass conversion, memory back-up, analogical inputs – outputs and open collector Printer (integrated in rack version), additivation control, sampler, coloration customs, process management… Project and After-Sales Services Through its Project Department and with a wide network of worldwide agencies and distributors, since the beginning of your project and all along its lifetime, Alma is able to bring you the full support for: Alma is fully certified for Metering Units and electronic batch controller manufacturing and repairing as well as: - Periodic control of metering units - Storage tanks calibration Budgetary pre study, general and detail engineering for metering solutions - Ex-Proof equipments manufacturing Turnkey metering projects and loading / unloading metering skids design, engineering - Operation in hazardous area and manufacturing. Operations and technical staff training AS BUILT documentation, Weight and Measures procedure and follow-up, legal periodical calibration, equipments approvals. Maintenance contracts and intervention, equipments up dating and evolution 47 rue de Paris 94470 Boissy-Saint-Léger France - phone nb: +33 1 45 69 44 70 fax: +33 1 45 69 16 02 email: [email protected] website: www.alma-alma.fr 4/4 FC052EN - august 2009 Dimensions Weight Electric Protection W&M Metrologic Certification Power Supply Measure Input