Hanna Instruments Canada
Transcription
Hanna Instruments Canada
Hanna Instruments Canada Company’s Profile pH / ORP / Temperature Measurement .................3 HANNA INSTRUMENTS CANADA Conductivity Measurement....................................9 Guide for Direct Soil Measurement.....................15 Combined Measurement ......................................16 Directions for Field Preparations of Soil Samples.....................................................20 Established in November 1990, Hanna Instruments Canada inc. has proven that good customer service is the key to success in the field of electro-analytical instrumentation. Our people are driven by your appreciation of our outstanding after-sales service and technical support. Hanna Instruments Canada is a member of the world’s leading manufacturer Hanna Instruments that has sales offices in over 30 countries. Dissolved Oxygen Measurement ........................21 Light Intensity Measurement ...............................23 Nutrient Management Chemical test kits....................................................24 Single/dual parameter Ion Specific Meter...............25 Grow Master ...........................................................26 Honey Color Analysis...........................................27 Maple Syrup Color Analysis ................................28 CUSTOMER SERVICE Thermometers & Hygrometers ............................29 Control Systems ...................................................36 For information or technical service. . . . . . . . . . . 1-800-842-6629 Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450-629-3335 General email . . . . . . . . . . . . . . . . . . . . . . . . [email protected] Technical service email. . . . . . . . . . . . . [email protected] Personalized Kits & Accessories ........................41 w w w . h a n n a c a n . c o m Calibration & Maintenance Solutions .................42 Warranty Policy.....................................................43 1 QUEBEC OFFICE T (450) 629-1444 F (450) 629-3335 BC OFFICE T (604) 572-7647 F (604) 572-7648 ONTARIO OFFICE T (905) 876-9358 F (905) 876-9359 2004 Agricultural Catalog pH / ORP / Temperature Measurement Testers The pHep®4 & pHep®5 comes with a replaceable probe for easy maintenance. The pHep®4 & pHep®5 include features such as a dual-level LCD, battery level indicator, replaceable pH electrode cartridge, temperature in °C or °F, stability indicator, automatic shut-off and automatic calibration all in a floating, waterproof casing. There is no other value like the pHep® brand of testers! These testers will go beyond your expectations! • • • • • • SPECIFICATIONS Range pH T° Resolution pH Waterproof, floating Large dual-level LCD Stability indicator % battery power illumination Automatic shut-off Automatic calibration T° pH T° Accuracy Temp. Comp. Battery Life Dimensions Weight pHep®4 - HI 98127 0.0 to 14.0 0.1 pHep®5 - HI 98128 0.00 to 14.00 0.0 to 60.0°C or 32.0 to 140.0°F 0.01 0.1°C or 0.1°F ± 0.1 ± 0.05 ± 0.5°C or ± 1°F Automatic Approx. 350 hours continuous use 163 x 40 x 26 mm (6.4 x 1.6 x 1”) 85 g (3.0 oz) INFO Champ ® pHep ® • • • • SPECIFICATIONS Range Resolution Accuracy Calibration Battery Life Dimensions Weight Cloth pull-out junction Large LCD 1 point calibration 0.2 pH accuracy Champ® - HI 98106 0.0 to 14.0 pH 0.1 pH ± 0.2 pH Manual 1 point Approx. 800 hours of cont. use 175 x 41 x 23 mm (7.9 x 1.8 x 1”) 78 g (2.7 oz) • • • • Cloth pull-out junction Large LCD 2 point calibration 0.1 pH accuracy pHep® - HI 98107 0.00 to 14.00 pH 0.1 pH ± 0.1 pH Manual 2 points Approx. 1700 hours of cont. use 175 x 41 x 23 mm (7.9 x 1.8 x 1”) 78 g (2.7 oz) 2004 Agricultural Catalog Most pesticides and fungicides perform more effectively when the pH of the tank mix is below 6.5 on the pH scale. Always check your chemical manufacturers directions for optimum pH levels. Economical pH Testers The Champ® incorporates a large LCD, pull-out cloth junction and Battery Error Prevention System in a rugged casing. The pHep® has 2 point calibration, large LCD, pull out junction and 1700 hours of battery life! No wonder they are the hot seller across Canada! 2 pH / ORP / Temperature Measurement Testers HI 98201 - ORP Tester HI 98120 & HI 98121 ORP/T° & Combo (pH/ORP/T°) testers Economical way to check the concentration of sanitizers HI 98120 & HI 98121 include features such as a dual-level LCD, battery level indicator, replaceable pH electrode cartridge, temperature in °C or °F, BEPS (Battery Error Prevention System) stability indicator, automatic shutoff and automatic calibration all in a floating, waterproof casing. In certain applications, ORP is used to determine the effects of soil compaction and the viability of the soil to maintain the proper level of oxygen. • • • • Another way to satisfy your needs ! SPECIFICATIONS HI 98120 HI 98121 Range pH 0.00 to 14.00 ORP ± 1000 mV ± 1000 mV T° 0.0 to 60.0°C or 32.0 to 140.0°F Resolution pH 0.01 ORP 1 mV 1 mV T° 0.1°C or 0.1°F Accuracy pH ± 0.05 ORP ± 2 mV T° ± 0.5°C or ± 1°F pH Calibration Automatic Temp. Comp. pH Automatic Battery Life Approx. 300 hours cont. use Approx. 250 hours cont. use Auto-off after 8 minutes of non use Dimensions 163 x 40 x 26 mm (6.4 x 1.6 x 1”) Weight 85 g (3.0 oz) Clog-resistant cloth junction Platinum electrode Covers full ORP range Large LCD & rugged housing SPECIFICATIONS ORP - HI 98201 Range ± 999 mV Resolution 1 mV Accuracy ± 5 mV Battery Life Approx. 700 hours continuous use Dimensions 175 x 41 x 23 mm (7.9 x 1.6 x 0.8”) Weight 78 g (2.7 oz) HI 98103CP pH Checkpak ® The ideal product for beginners & hobbyists The pH Checkpak® includes the Checker®1 pH tester which provides growers with fast and accurate pH readings. The Checker®1 is easy to calibrate, uses a replaceable pH electrode and works for 3000 hours before you have to change the batteries! • • • Large easy to read LCD Renewable junction Rugged ergonomic casing SPECIFICATIONS Range Resolution Accuracy Battery Life Dimensions Weight 3 Including pH tester, solutions, calibration screwdriver and instruction manual. pH Checkpak® - HI 98103CP 0.00 to 14.00 pH 0.01 pH ± 0.2 pH Approx. 3000 hours continuous use 66 x 50 x 25 mm (2.6 x 2 x 1”) 70 g (2.5 oz) HI 98103GC Growers Field Checker® Read pH directly on the sample! • • • • • • Measure directly from the sample Large LCD High accuracy with 0.01 pH resolution 2 point calibration Full range: 0.00 to 14.00 pH Pocket size The Growers Field Checker® HI 98103GC, allows the user to dertermine the pH of fruit and plant tissue in the field with just a few drops of sap or juice. If your sample does not contain sufficient liquid, add an equal portion of deionized water to extract the sample pH. Hanna Instruments Growers Field Checker® works with you to help obtain superior crops. It is supplied with a flat tip pH probe, which allows for minimal liquid samples, soft carrying case, pH 4 & pH 7 calibration solution, deionized water sachet, 100 ml sample beaker and screwdriver. SPECIFICATIONS Range Resolution Accuracy Calibration Electrode Battery Life Dimensions Weight Growers Field Checker - HI 98103GC 0.00 to 14.00 pH 0.01 pH ® ± 0.2 pH Manual 2 points through trimmers HI 1413S/50 (included) Approx. 3000 hours continuous use 66 x 50 x 25 mm (2.6 x 2 x 1”) 70 g (2.5 oz) 2004 Agricultural Catalog pH / ORP / Temperature Measurement Monitors INFO pH Meters Calibration & Maintenance pH & T° monitor pH meter calibration Single point calibration • Soak your tester/probe 1 inch (2.5 cm) deep into pH 7.01 calibration solution. • Wait 20-30 sec. for reading to stabilize. • Adjust calibration screw/knob to read 7.0 on display. • Verify tester by soaking in pH 4.01 calibration solution, and waiting for reading to stalilize at a reading of 4.0. • Your meter/tester is calibrated & ready to go! *Perform calibration at least every 5-7 days and/or after cleaning procedure. The Gro’Chek from Hanna has a dual-level backlit LCD to give you instantaneous readings of both pH and temperature. The microprocessor provides automatic calibration, automatic buffer selection and automatic temperature compensation. • • • • • • Waterproof Dual-level backlit LCD Combination pH/To probe SPECIFICATIONS Range pH T° Resolution pH T° Accuracy pH T° Temp. Comp. Power Supply Dimensions Weight Stability indicator Extra large display 12 VDC power supply Double point calibration • Soak your tester/probe 1 inch (2.5 cm) deep into pH 7.01 calibration solution. • Wait 20-30 sec. for reading to stabilize. • Adjust pH 7 calibration screw/knob to read 7.0 on display. • Remove tester/probe and rinse with tap water. • Soak your tester/probe 1 inch (2.5 cm) deep into pH 4.01 calibration solution. • Wait 20-30 sec. for reading to stabilize. • Adjust pH 4 calibration screw/knob to read 4.0 on display. • Your meter/tester is calibrated & ready to go! *Perform calibration at least every 5-7 days and/or after cleaning procedure. HI 991401 0.00 to 14.00 0.0 to 60.0°C or 32.0 to 140.0°F 0.01 0.1°C or 0.1°F ± 0.01 ± 0.5°C or ± 1°F Automatic External 12 VDC (included) 160 x 105 x 31 mm (6.2 x 4.1 x 1.2”) 190 g (6.7 oz) **For meters/testers equipped with automatic calibration, please refer to instruction manual. pH meter maintenance Cleaning procedure • Soak your tester/probe 1 inch (2.5 cm) deep into HI 7061 cleaning solution for 1 hour. • Next soak terster/probe in HI 70300 sotrage solution to rehydrate. • Rinse with tap water and perform a calibration prior to use. • Should you not need to use your tester/meter for a few days, store it into HI 70300 storage solution (see below). *Periodic cleaning of testers/probes will eliminate erratic readings and unexpected tester/probe replacement. pH Monitor with Large LCD The popular Gro’Chek pH monitor has been updated with a larger, easy-to-read LCD. Waterproof casing guarantees operation after accidental exposure to water. Greenhouses high humidity is not a threat to this rugged monitor. Its professional pH electrode gives you accurate results every time. • • • • • SPECIFICATIONS Range Resolution Accuracy Temp. Comp. Power Supply Dimensions Weight Storage • Should you not forecast to use your tester/meter for a few days, simply fill its sensor cap with HI 70300 storage solution. • For long term storage (months), it is recommended to fill a container with 2 inches (5 cm) of HI 70300 storage solution and let the tester/probe sit in it. Monitor the storage solution level periodically as it will evaporate over time. *Storage prevents pH sensors from premature degradation and allows for ultra fast sensor response/reading. A sensor left dry for more than 2-3 months will give slow response, will suffer from drifting of readings and other malfunctions. A sensor replacement will then be needed. Waterproof Rugged housing Large LCD High accuracy 12 VDC power supply HI 991401 0.0 to 14.0 pH 0.1 pH ± 0.2 pH Manual 2 points External 12 VDC (included) 84 x 94 x 33 mm (3.4 x 3.7 x 1.3”) 150 g (53 oz) 2004 Agricultural Catalog Installation for in-line applications Water Source Injector pH Electrode Acid or Fertilizers 4 pH / ORP / Temperature Measurement Monitors ORP indicator with alarm signals HI 982401 is a simple-to-operate and practical meter for ORP (Oxidation Reduction Potential) measurements. It continuously monitors ORP from - 999 to + 999 mV. The HI 982401 front case also incorporates a large, bright LED indicator. Should the measurements fall below the user-selectable ORP values, the red LED starts flashing to alert the operator of an undesired condition. Both the LCD showing the measurements and the LED can be seen even from a distance. HI 982401 can be mounted in confined spaces and right next to the vat or barrel containing the chemicals. This casing also incorporates a molded eye so that it can installed with just a screw. • • • • • Made for small washing stations and vegetable processing High quality optional HI 3214P/2 electrode is recommanded ORP monitored continuously Compact, practical and easy-to-install 12 VDC power supply INFO ORP (Oxidation Reduction Potential) is a fast reliable method to determine the concentration and effectivness of sanitizers. Wash stands, vegetable washers, irrigation line clean out, even maple sap lines can all be monitored SPECIFICATIONS Range Resolution Accuracy Setpoint Electrode Power Supply Dimensions Weight Special pH/ORP electrodesfor HI 982401 & HI 981406 SPECIFICATIONS HI 2114P/2 HI 3214P/2 Junction Cloth Shape Sphere ROD Plug BNC Pressure (Bar/PSI) 3/43.5 Cable Coaxial T° range 0 to 80°C Body Ultem® Junction Reference Double Cell Reference Gel pH/ORP Combo • • 2 in 1: pH & ORP monitored simultaneously Compact, pratical & easy-to-install pH & ORP monitor with LED alarm signals HI 981406 has been specially designed for water treatment applications where both pH and ORP (Oxidation Reduction Potential) need to be monitored. There are two separate setpoints for pH and ORP which the operator can adjust at will. Once the pH setpoint is exceeded, the appropriate LED light will come on to alert the operator. Likewise, once the ORP level drops below the setpoint, the red ORP light will stay on. HI 981406 is supplied with HI 1283 ground probe that basically prevents currents which are prevalent in water basins, from disturbing the measurements. The optional HI 2114P/2 pH electrode and HI 3214P/2 ORP electrode are specially designed for the swimming pool market. Their purpose-built fiber salt-bridge is particularly resistant to clogging in pools. 5 HI 982401 ± 999 mV 1 mV ± 5 mV Selectable from 350 to 850 mV HI 3214P/2 platinum ORP electrode (optional) External 12 VDC (included) 89 x 94 x 33 mm (3.3 x 3.7 x 1.3”) 150 g (5.3 oz) SPECIFICATIONS Range pH mV Resolution pH mV Accuracy pH mV Calibration pH Setpoints pH ORP Alarm Probes Power Supply Dimensions Weight HI 981406 0.0 to 14.0 ± 999 0.1 1 ± 0.2 ±5 Manual 1 or 2 points Adjustable from 5.0 to 9.0 pH Adjustable from 350 to 850 mV 2 LED’s. ON when the pH is > or ORP is < than the setpoints HI 2114P/2 pH electrode & HI 3214P/2 ORP electrode (optional) HI 1283 grounding bar with 2 m cable (included) 12 VDC adapter 165 x 110 x 35 mm (3.4 x 3.7 x 1.3”) 300 g (10.6 oz) 2004 Agricultural Catalog pH / ORP / Temperature Measurement Professional Meters HI 991001 & HI 991002 SPECIFICATIONS Range Resolution Accuracy pH Calibration Temperature Comp. Electrode includes Battery Type/Life Dimensions Weight HI 991001 pH ORP T° pH ORP T° pH ORP T° HI 991002 -2.00 to 16.00 - ± 1999 mV -5.0 to 105.0°C or 23.0 to 221.0°F 0.01 - 1 mV 0.1°C or 0.1°F ± 0.02 ± 2 mV ± 0.5 up to 60°C, ± 1°C up to 105°C (± 1°F up to 140°F, ± 2°F up to 221°F) Automatic 1 or 2 points with 2 set of standardized buffers (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18) Automatic from -5 to 105°C (23 to 221°F) (for pH only) HI 1296D combination amplified pH/temperature HI 1297D combination amplified pH/ORP/T° with DIN connector and 1 m (3.3’) cable with DIN connector and 1 m (3.3’) cable 3 x 1.5V AA / approximately 1500 hours of continuous use. Auto-off after 8 minutes 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”) 245 g (8.6 oz) Extended range waterproof pH/T° & pH/ORP/T° meters The new HI 991001 and HI 991002 meters from Hanna offer IP 67 waterproof protection in a compact casing. The included multi-parameter electrode has a built-in temperature sensor. No additional temperature probe is required. The electrode also contains a mini amplifier to render your measurements impervious to noise and electrical interference. The large display shows readings in an extended range from -2.00 to 16.00 pH and simultaneously shows temperature from -5.0 to 105.0 °C or 23 to 221°F. HI 991002 also measures ORP from -1999 to 1999 mV. The mV scale of this meter can be used with the available HI 1296D pH/temperature electrode to check the condition of the pH electrode. These meters have a stability indicator and hold feature that prompts you when to take the reading & freezes the display for easy and accurate recording. The large display also has graphic symbols to guide you through all operations. The battery life of the meters guarantee over 1500 hours of continuous use. At startup, they perform a self-check and then display the remaining battery level to assure proper working condition. Calibration is performed automatically at one or two points using standard or N.I.S.T. buffers. HI 99141 SPECIFICATIONS Range Resolution Accuracy • • • • Rugged electrode Automatic calibration Messages on the display Automatic Temperature Compensation Boilers and cooling towers pH meter pH Calibration Temperature Comp. Electrode Battery Type/Life Dimensions Weight pH T° pH T° pH T° HI 991001 -2.00 to 16.00 -5.0 to 105.0°C or 23.0 to 221.0°F 0.01 0.1°C or 0.1°F ± 0.02 ± 0.5 up to 60°C; ± 1°C (outside); ± 1°F up to 140°F, ± 2°F (outside) Automatic 1 or 2 points with 2 set of standardized buffers (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18) Automatic HI 72911 amplified pH electrode with built-in temperature sensor & matching pin (included) 3 x 1.5V AA / approximately 1500 hours of continuous use. Auto-off after 8 minutes 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”) 207 g (7.3 oz) Hanna’s HI 99141 is a waterproof, portable pH/temperature meter specifically designed for boiler & cooling tower applications. HI 72911 double junction pH electrode (included) has an unbreakable stainless steel body and a flat tip. The electrode also features an annular Teflon® junction for maximum surface contact giving increased response and stability. The stainless steel body of the probe functions as a shield and adds to the sensor’s life. The flat tip is easy to clean and prevents solids in solution from collecting on the sensor. This advanced electrode also contains an integral temperature sensor and a mini amplifier to boost the electrode signal eliminating the effects of noise and interference. The meter reads from -2.00 to 16.00 pH while simultaneously showing the temperature in °C or °F. Graphic icons guide operations and a stability indicator with hold feature determines when to freeze the reading for easy record keeping. Calibration is performed automatically at one or two points with standard or NIST calibration buffers. Battery life is over 1500 hours and at startup, the LCD shows the remaining battery power. In addition, BEPS (Battery Error Prevention System) prevents bad readings due to low voltage and an auto-off period of 8 minutes saves battery power. 2004 Agricultural Catalog 6 pH / ORP / Temperature Measurement Professional Meters HI 99121 • Test pH directly in soil, media and compost material. Precision kit for measuring pH of soil directly with special electrode The HI 99121 kit has been designed to address the question of correct and rapid measurement of pH directly in soil. Every item in this kit has been made to facilitate measurements in the field without compromising accuracy. HI 99121 can test the pH of soil directly or after preparation of a diluted sample. In order to measure the pH directly, the kit includes a plastic auger to perforate the ground. The pH and temperature can be directly tested with the 3-in-1 conic shaped electrode with even a slightly moist soil. For higher degrees of accuracy, or for stony ground where the electrode may be damaged, use the specially made HI 7051 test solution. This solution is included in the package to help you measure pH more precisely by diluting a sample of the soil in it. The kit naturally includes a pH meter. However, in order to facilitate fast and reliable measurements, the supplied pH meter is HI 991001 complete with HI 1292D electrode, pH 4 and pH 7 calibration sachets, beaker, auger and a practical and rugged carrying case. HI 991001 meter is waterproof and sophisticated yet engineered for its simplicity. The 3-in-1 pH electrode, HI 1292D, has been designed for direct soil measurement. It has a conic, rugged tip and can be directly inserted in moist or soft soil. The electrode incorporates a temperature sensor right near the tip to enable it to measure and compensate for the temperature quickly. It also houses a miniaturized amplifier to provide greater stability in spot measurements. The dual-level LCD shows the pH value from -2 to 16 in hundredths of units. It also displays the temperature on the secondary level at the same time. With a menu-driven custom microprocessor, the user is helped with clear prompts during operation and calibration. SPECIFICATIONS Range Resolution Accuracy pH Calibration Temperature Comp. Electrode Battery Type/Life Dimensions Weight 7 pH T° pH T° pH T° INFO Direct pH measurement is very important when checking trends in large operations. Fast, effective verification can detect problems before they become costly. See section on how to do Direct Soil Measurement HI 99121 -2.00 to 16.00 -5.0 to 105.0°C or 23.0 to 221.0°F 0.01 0.1°C or 0.1°F ± 0.02 ± 0.5 up to 60°C, ± 1°C up to 105°C (± 1°F up to 140°F, ± 2°F up to 221°F) Automatic 1 or 2 points with 2 set of standardized buffers (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18) Automatic HI 1292D glass pH/temperature electrode, with amplifier, DIN connector & 1 m cable (3.3’) (included) 3 x 1.5V AA / approximately 1500 hours of continuous use 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”) 245 g (8.6 oz) 2004 Agricultural Catalog Conductivity Measurement Testers HI 73311 Graphite electrode cartridge! The DiST®5 and DiST®6 include features such as waterproof casing plus 100% buoyancy, adjustable TDS ratio, temperature in °C and °F, adjustable ß, Automatic shut-off and automatic calibration. This tester in unmatched in EC/TDS/T° measurement! • • • • • • • Waterproof, floating % battery power illumination Large dual-level LCD Adjustable TDS ratio Adjustable ß Automatic shut-off Automatic calibration User adjustable TDS ratio Battery life percentage illuminated SPECIFICATIONS Range EC TDS T° Resolution EC TDS T° Accuracy EC TDS T° EC/TDS Calibration EC/TDS Conv. Factor Temp. Comp. Battery Life Dimensions Weight DIST®5 - HI 98311 DIST®6 - HI 98312 0 to 3999 µS/cm 0.00 to 20.00 mS/cm 0 to 2000 ppm 0.00 to 10.00 ppt 0.0 to 60.0°C (32.0 to 140.0°F) 1 µS/cm 0.01 mS/cm 1 ppm 0.01 ppt 0.1°C (0.1°F) ± 2% F.S. ± 2% F.S. ± 0.5°C (± 1°F) Automatic 1 point Adjustable from 0.45 to 1.00 Automatic, ß is adjustable from 0.0 to 2.4 %/°C 4 x 1.5 V with BEPS approx. 100 hours continuous use Auto shut-off after 8 minutes of non-use 163 x 40 x 26 mm (6.4 x 1.6 x 1”) 85 g (3.0 oz) pNa INFO Portable Sodium tester What is TDS ? The pNa tester is the most economical and reliable way to determine sodium levels in soil. Sodium in the irrigation water can be caused by underground deposits, road salt leaching or saline soils. High levels of sodium can cause poor aeration and decrease the ability of the plant to take nutrients. Total Dissolved Solids (TDS) is defined as the amount of solids dissolved in a solution. DiST® Economical EC and TDS testers with ATC This DiST family of testers utilize a graphite sensor interface for greater accuracy and external temperature sensor for quicker more stable readings. The DiST features a large LCD, BEPS (Battery Error Prevention System) and rugged housing for longer life. • • • • • Graphite sSensor Quick accurate readings Large LCD Rugged housing DiST®1 TDS ratio= 0.5 • • • SPECIFICATIONS Range Resolution Accuracy Calibration solution Calibration Temp. Comp. Battery Life Dimensions Weight 2004 Agricultural Catalog Cloth junction reference Rugged body pNa determination graph included DIST®1 - HI 98301 0 to 1999 ppm (mg/l) 1 ppm (mg/l) HI 70032/HI 70442 SPECIFICATIONS Range Resolution Accuracy Calibration Battery Life Dimensions Weight pNa - HI 98202 0.0 to 3.0 pNa (23 to 0.023 g/l of Na+) 0.1 pNa ± 0.2 pNa Manual 1 point through trimmer Approx. 500 hours continuous use 175 x 41 x 23 mm (7.9 x 1.8 x 1”) 78 g (2.7 oz) DIST®2 - HI 98302 DIST®3 - HI 98303 0.00 to 10.00 ppt (g/l) 0 to 1999 µS/cm 0.01 ppt (g/l) 1 µS/cm ± 2% F.S. HI 70038P HI 70031P Manual 1 point through trimmer Automatic from 0 to 50°C (32 to 122°F) 4 x 1.5 V, approx. 150 hours continuous use 175 x 41 x 23 mm (7.9 x 1.8 x 1”) 78 g (2.7 oz) DIST®4 - HI 98304 0.00 to 19.99 mS/cm 0.01 mS/cm HI 70039P/HI 70030P 8 Conductivity Measurement Testers SALINTEST SPECIFICATIONS SALINTEST - HI 98203 Range 0.00 to 1.00 pNaCl (58.4 to 5.84 g/l of NaCl) Resolution 0.01 pNaCl Accuracy ± 0.02 pNaCl Typical EMC deviation ± 0.04 pNaCl Calibration Manual 1 point through trimmer Battery Life 4 x 1.5 V/approx. 500 hours continuous use Dimensions 175 x 41 x 23 mm (7.9 x 1.8 x 1”) Weight 78 g (2.7 oz) Measure the salt content of water Worldwide fish farming has made great strides in the past two decades with aquaculture becoming a prime source for quality seafood in an ever growing industry. As the methods and products keep changing, one crucial factor remains the same: the salinity of the water. The main component of salt in seawater is sodium chloride. The SALINTEST can help you monitor the concentration of sodium chloride assuring high quality in aquaculture. SALINTEST is also ideal for marine fish tanks and aquariums. Instruments for measuring salinity of seawater currently available on the market are cumbersome and difficult to use. Hanna has re-engineered this compact salt tester with a more durable, ergonomic casing and a larger LCD. Besides applications in aquaculture, SALINTEST is also ideal for checking salt concentrations in live fish storage tanks, tropical fish aquariums, refrigerated storage and oceanographic investigation. • • • • Perfect for marine fish tanks and tropical aquariums Highly portable for easy use around aquaculture installations A rugged addition to your marine toolkit for oceanographic study The large LCD allows quick and easy readings when checking seafood storage tanks AquaDip® TDS 601 Rugged waterproof TDS/T° meter with 2 year warranty Low cost TDS meter with Automatic Temperature Compensation SPECIFICATIONS Range Resolution Accuracy Typical EMC Deviation TDS Factor Calibration solution Temperature Comp. Battery Life Dimensions Weight TDS 601 0 to 1990 ppm (mg/l) 10 ppm ± 2% F.S. ± 2% F.S. 0.5 HI 70032P (optional) Automatic from 5 to 50°C (41 to 122°F) 4 x 1.4 V alkaline/Approx. 150 hours of continuous use 150 x 30 x 24 mm (5.9 x 1.2 x 0.9”) 85 g (3 oz) • • • • • • Low maintenance No calibration Long stem for mixing Robust Easy to use Auto shut-off after 5 minutes SPECIFICATIONS Range TDS T° Resolution TDS T° Accuracy TDS T° TDS Factor Calibration Temperature Comp. Battery Life Dimensions AquaDip® - HI 983310 0 to 1999 ppm 0.0 to 60.0°C 1 ppm 0.1°C ± 2% F.S. ± 0.5°C 0.5 Factory calibrated Automatic from 0 to 60°C = 2%/°C 2 x 1.5 V AAA alkaline 92 x 38 x 450 mm (3.6 x 1.5 x 17.7”) PWT Pure Water Test Pure Water Test (PWT) enables you to check the purity of your distilled or demineralized water in laboratory or industrial environments. PWT is ideally suited for fields such as Printed Circuit Board washing, laundry, steam cleaning, checking car battery water and all areas where distilled, demineralized or pure water is used. • • 9 Pure Water Test Filtration systems in maple syrup production can save boiling costs by removing sugar first. Verifying the condition of membranes can be done efficiently with the PWT. SPECIFICATIONS PWT - HI 98308 Range 0.0 to 99.9 µS/cm Resolution 0.1 µS/cm Accuracy ± 2% F.S. Typical EMC deviation ± 2% F.S. Calibration Manual 1 point through trimmer Battery Life 4 x 1.5 V/approx. 250 hours continuous use Dimensions 175 x 41 x 23 mm (7.9 x 1.8 x 1”) Weight 78 g (2.7 oz) 2004 Agricultural Catalog Conductivity Measurement Monitors EC & TDS monitors with large LCD • • • • • SPECIFICATIONS Range Resolution Accuracy Calibration Waterproof Rugged housing Large LCD High accuracy 12 VDC power supply The popular Gro’Chek EC/TDS monitor has been upgraded with a larger, easy-to-read LCD. Plus the waterproof casing guarantees operation after accidental water exposure. High humidity in greenhouses is not a threat to this rugged monitor. The professional probe gives you accurate results every time. TDS GRO’CHEK - HI 983301N 0 to 1999 mg/l (ppm) 10 mg/l Temperature Comp. TDS Conv. Factor Probe included Power Supply Dimensions Weight 0.7 HI 7634 TDS probe Water-resistant Conductivity and TDS meters with visual alarm Water-resistant conductivity/TDS meters are Hanna’s reply to requests of accurate process monitoring at highly affordable costs and low maintenance. Each meter is supplied with a direct 2-pin probe and 2 meter (6.6') cable with a ½" thread for in-line mounting. The probe has a temperature sensor to automatically compensate against temperature changes from 5 to 50°C (41 to 122°F) with a ß of 2% per degree. A front trimmer allows manual calibration at 1 point. The electrical circuitry is tightly sealed inside the water-resistant enclosure. The 12 VDC power supply allows continuous monitoring over extended periods of time. 2004 Agricultural Catalog TDS GRO’CHEK - HI 983301N/5 0 to 1990 mg/l (ppm) 10 mg/l ± 2% F.S. Manual with one trimmer EC GRO’CHEK - HI 983302N 0.00 to 9.99 mS/cm 0.01 EC Automatic from 5 to 50°C (41 to 122°F) with ß = 2% 0.5 HI 7634 TDS probe External 12 VDC (included) 86 x 94 x 33 mm (3.3 x 3.7 x 1.3”) 150 g (5.3 oz) HI 7632 EC probe SPECIFICATIONS TDS PRONTO - HI 983306 EC PRONTO - HI 983307 Range 0 to 1990 mg/l (ppm) 0.00 to 9.99 mS/cm Resolution 10 ppm 0.01 mS/cm Accuracy ± 2% F.S. Calibration Manual 1 point through trimmer Calibration solution HI 70032P HI 70039P Temperature Comp. Automatic from 5 to 50°C (41 to 122°F) with ß = 2% Setpoint 200 to 1600 ppm 0.70 to 3.50 mS/cm Probe HI 7634/2 TDS probe (included) HI 7632/2 EC probe (included) Power Supply External 12 VDC (included) Dimensions 86 x 94 x 33 mm (3.3 x 3.7 x 1.3”) Weight 150 g (5.3 oz) 10 Conductivity Measurement Monitors EC/TDS/T° monitors with large backlit LCD • • • • • • • These new monitors from Hanna have a large, dual-level, back-lit LCD to give you instantaneous readings of both EC/TDS and temperature even from a distance. The waterproof EC/TDS indicators HI 993301 and HI 993302 have been designed to meet the Grower's need for equipment suited to the aggressive environments found in agricultural and hydroponics applications. At startup, HI 993301 and HI 993302 perform a self-check to assure proper working condition. These powerful instruments also feature a stability indicator and hold feature to prompt the user when to take the reading and freeze the display for easy and accurate recording. Calibration and temperature compensation is automatic, while the EC/TDS conversion factor and temperature cœfficient factor (ß) are user adjustable for application specific measurements. Waterproof Dual-level backlit LCD Adjustable TDS ratio Combination EC/tDS/T° probe Adjustable ß Extra large display 12 VDC power supply SPECIFICATIONS Range EC TDS HI 993301 0 to 3999 µS/cm 0 to 2000 ppm T° EC TDS T° Accuracy EC TDS T° Temp. Compensation Probe Power Supply Dimensions Weight HI 993302 0.00 to 20.00 mS/cm 0.00 to 10.00 ppt 0.0 to 60.0°C or 32.0 to 140.0°F Resolution 1 µS/cm 1 ppm 0.01 mS/cm 0.01 ppt 0.1°C or 0.1°F ± 2% F.S. ± 2% F.S. ± 0.5°C or ± 1°F Automatic, ß adjustable from 0.0 to 2.4%/°C HI 7630 EC/TDS probe External 12 VDC (included) 165 x 110 x 35 mm (6.5 x 4.3 x 1.3”) 330 g (11.0 oz) Installation for in-line applications Water Source Injector EC Acid or Fertilizers INFO What is EC ? Electrical Conductivity (EC) is defined as the ability of a solution to conduct an electrical current. In aqueous solutions conductivity is directly proportional to the concentration of dissolved solids; the higher concentration of solids, the greater the conductivity. 11 2004 Agricultural Catalog Conductivity Measurement Professional meters HI 98321 & HI 98322 EC/TDS/Temperature scoop meters The HI 98321 & HI 98322 portable meters from Hanna are designed for quick and easy, high accuracy EC, TDS and Temperature measurements. These waterproof instruments have a dual-level LCD that displays EC or TDS and °C or °F. These microprocessor meters have been developed in direct response to the requests of users in water treatment, water quality, boilers and cooling towers, reverse osmosis and agrriculture. Developed for users in • Agriculture • Water treatment • Boilers • Reverse osmosis HI 9835 SPECIFICATIONS Range EC TDS T° Resolution EC TDS HI 98321 HI 98322 0 to 3999 µS/cm 0.00 to 20.00 mS/cm 0 to 2000 ppm 0.00 to 10.00 ppt 0.0 to 60.0°C or 32.0 to 140.0°F 1 µS/cm 0.01 mS/cm 1 ppm 0.01 ppt T° EC TDS T° EC/TDS calibration EC/TDS Conv. Factor Temp. Comp. Battery Life Dimensions Weight 0.1°C or 0.1°F ± 2% F.S. ± 2% F.S. ± 0.5°C or ± 1°F Automatic 1 point at 1413 µS/cm Automatic 1 point at 12,88 mS/cm Adjustable from 0.45 to 1.00 ß adjustable from 0.0 to 2.4%/°C Approx. 100 hours continuous use 120 x 53 x 81 mm (4.7 x 2.1 x 3.1”) 225 g (7.8 oz) Accuracy SPECIFICATIONS Range EC TDS EC/TDS/NaCl/°C meter The HI 9835 combines the more important parameters you need for measuring conductivity. Now you can sample EC, TDS, NaCl and temperature all at once. Hanna’s probe design innovation uses 4 rings enhanced with platinum for greater stability while increasing the range of measurable concentrations and temperature. You can choose between automatic and manual temperature compensation to facilitate your operating requirements. In addition, you can also select from a range of TDS factors from 0.40 to 0.80 and a range of cœfficients 0.00 to 6.00% for greater consistency and reproducibility. The housing is completely waterproof and built to survive the harsh conditions of field use. For extended time studies, this meter can be connected to the available 12 VDC power supply. NaCl T° Resolution EC TDS NaCl T° Accuracy EC/TDS/NaCl T° Temp. Comp. Power Supply Dimensions Weight 2004 Agricultural Catalog HI 9835 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; Up to 500.0 mS/cm 0.00 to 14.99 ppm; 15.0 to 149.9 ppm; 150 to 1499 ppm; 1.50 to 14.99 ppt; 15.0 to 100.0 ppt; Up to 400.0 ppt 0.0 to 400.0% 0.0 to 60.0°C 0.01 µS/cm (from 0.00 to 29.99 µS/cm); 0.1 µS/cm (from 30.0 to 299.9 µS/cm); 1 µS/cm (from 300 to 2999 µS/cm); 0.01 mS/cm (from 3.00 to 29.99 mS/cm); 0.1 mS/cm (over 30.0 mS/cm) 0.01 ppm (from 0.00 to 14.99 ppm); 0.1 ppm (from 15.0 to 149.9 ppm); 1 ppm (from 150 to 1499 ppm); 0.01 ppt (from 1.50 to 14.99 ppt); 0.1 ppt (over 15.0 ppt) 0.1% 0.1°C ± 1% of reading ± 0.4°C Automatic or manual 4 x 1.5 V AA or 12 VDC adapter 196 x 80 x 60 mm (7.7 x 3.1x 2.4”) 500 g (18 oz) 12 Conductivity Measurement Professional meters HI 993310 Dual-purpose, EC meter for direct measurement in soil and liquids Since EC (Electroconductivity) is such an effective indicator of nutrient concentration in soil, irrigation water and fertilizer mixes, the HI 993310 was developed. Now it is possible to use one instrument to accurately and quickly measure EC in many places where the fertilizer is found, such as in the irrigation water and directly in the soil. This meter is easy to operate and gives fast, accurate measurements. Also included in the meter is the ability to measure salt activity. Comes complete with HI 76304 and HI 76305 interchangeable probes. SPECIFICATIONS Range Resolution Accuracy Temp. Comp. Battery Life Dimensions Weight HI 993310 0.00 to 19.99 mS/cm; 0.00 to 1.00 g/l of salt activity 0.01 mS/cm; 0.01 g/l of salt activity ± 2% F.S. (from 0 - 15.00 mS/cm, excl. probe error) Automatic Approx. 100 hours continuous use 185 x 82 x 45 mm (7.3 x 3.2 x 1.8”) 355 g (13 oz) • • • • • Direct soil and liquid EC measurement Measures EC in soil, irrigation water and fertilizer mixes Easy to calibrate and use Rapid, accurate measurements Automatic Temperature Compensation HI 9033 & HI 9034 SPECIFICATIONS Ranges Resolution • • • One probe for many ranges Waterproof 4 ring probe excels Accuracy Calibration Temp. Comp. Probe Battery type/life Dimensions Weight HI 9033 HI 9034 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.0 to 199.9 mg/l; 0 to 1999 m 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm 0.00 to 19.99 g/l 0.1 µS/cm; 1 µS/cm; 0.1 mg/l; 1 mg/l; 0.01 g/l 0.01 mS/cm; 0.1 mS/cm ± 1% F.S. (excluding probe error) Manual 1 point with trimmer Automatic from 10 to 50°C with ß of 2% per degree °C HI 76302W with ATC, 1 m cable (included) 1 x 9 V / approximately 100 hours of continuos use 196 x 80 x 60 mm (7.7 x 3.1 x 2.4”) 425 g (15 oz); kit: 1.4 kg (3.1 lb.) Waterproof multirange Conductivity or TDS Ideal for measuring samples from deionized water to fertilizer stock tanks. HI 9033 and HI 9034 have been proven time and again to hold up under extended use in wet, humid, dusty and muddy conditions. HI 9033 utilizes a single probe to perform all conductivity readings in four ranges. This allows the user to measure samples from deionized water to fertilizer concentrate without having to switch or recalibrate the probe. HI 9034 measures total dissolved solids (TDS) in three ranges to offer the highest accuracy when performing measurements in diverse applications such as HVAC, waste water treatment and reverse osmosis. All three ranges can be activated at the touch of a button without having to change the conductivity probe. Both meters perform measurements with ATC (automatic temperature compensation) which adjusts for the effects of temperature. These portable instruments also feature BEPS (Battery Error Prevention System) technology that alerts the user when low batteries could affect the readings. 13 2004 Agricultural Catalog Guide for Direct Soil Measurement HI 99121 Waterproof soil & liquid pH meter HI 993310 Direct soil & liquid EC meter GUIDE FOR DIRECT SOIL MEASUREMENT 1) When checking direct soil pH and conductivity, always remember you will be making a reference between TRUE and SOIL reference values. 5) The next step is to take the measurements directly in the soil, again, following the instructions from the operators manual. 2) Start by gathering samples of the soil medium and draw a reference table to record your data. Note : these readings will be different from the dilute solution readings due to the physical properties of the two materials and the effects on conductivity. Dilute Solution 6) Record your measurements on the second line of the pH or conductivity reference table. Soil 3) Prepare a dilute solution with each sample (example : 2 parts distilled water for 1 part soil). 4) Take the measurements of the dilute solutions with the HI 99121 or the HI 993310, following the instructions in the operators manual, and record this data on the first line of the reference table for either pH or conductivity. Your local agronomist or crop advisor will help you determine if these values are correct. pH Dilute Solution Soil 6.5 6.4 6.5 Dilute Solution 2.2 Dilute Solution 6.5 6.4 6.5 Soil 5.9 5.8 5.9 7) During the measurements in soil, always use consistent and repeatable measuring techniques for analysis. Example : - always test at the same time interval after irrigation; - use same depth in each pot or bag; - use same distance and depth from drip emitter; - same medium types. 8) When the chart is complete, you will compare the true and soil reference values. If there are no large differences between these two values, you are ready to begin measuring directly in the soil using only the soil reference values as a target. EC or pH 2.3 2.4 Soil 2004 Agricultural Catalog 14 Combined Measurement Testers & monitors SPECIFICATIONS Range The only tester in the world that measures pH, Conductivity, TDS and Temperature! The HI 98129 and HI 98130 Combo waterproof testers are designed for high accuracy pH, EC/TDS and temperature measurements. No more switching between meters, the Combo from Hanna Instruments, does it all! HI 73127 Replaceable pH electrode cartridge! • • • • • • • • Waterproof, floating % battery power illumination High accuracy Large dual-level LCD Adjustable TDS ratio Adjustable ß Automatic shut-off Automatic calibration HI 98129 HI 98130 pH 0.00 to 14.00 0.00 to 14.00 EC 0 to 3999 µS/cm 0.00 to 20.00 mS/cm TDS 0 to 2000 ppm 0.00 to 10.00 ppt T° 0.0 to 60.0°C or 32.0 to 140.0°F Resolution pH 0.01 0.01 EC 1 µS/cm 0.01 mS/cm TDS 1 ppm 0.01 ppt T° 0.1°C or 0.1°F Accuracy pH ± 0.05 EC/TDS ± 2% F.S. T° ± 0.5°C or ± 1°F Temp. Comp. pH: Automatic; EC: Automatic: ß adjustable from 0.0 to 2.4%/°C Battery Life Approx. 100 hours continuous use Dimensions 163 x 40 x 26 mm (6.4 x 1.6 x 1”) Weight 85 g (3.0 oz) INFO Save time and money! Carry one unit, perform several tests. HI 981404N & HI 981405N pH & TDS or EC continuous monitors • • • • SPECIFICATIONS Range Resolution Accuracy Calibration Temp. Comp. TDS conv. Factor Probes (included) Power Supply Dimensions Weight 15 2 parameters with a single instrument Advanced electrode technology Simple operation and maintenance Supplied complete and ready to use HI 981404N HI 981405N 0.0 to 14.0 pH; 0 to 1990 mg/l (ppm) 0.0 to 14.0 pH; 0.00 to 9.99 mS/cm 0.1 pH; 10 mg/l (ppm) 0.1 pH; 0.01 mS/cm ± 0.2 pH; ± 2% F.S. ± 0.2 pH; ± 2% F.S. Manual at 1 or 2 point (pH) Manual at 1 or 2 point (pH) Manual at 1 point (TDS) Manual at 1 point (EC) Auto from 5 to 50°C (41 to 122°F) (TDS) Auto from 5 to 50°C (41 to 122°F) (EC) 0.7 ppm = 1 µS/cm HI 1286 interchangeable pH electrode HI 1283 grounding bar with 2 m (6.6’) cable HI 7634 TDS probe(fixed) HI 7632 EC probe (fixed) 12 VDC adapter (included) 165 x 110 x 35 mm (6.5 x 4.3 x 1.3”) 300 g (10.6 oz) HI 981404N and HI 981405N are ideal for agricultural, horticultural and hydroponics applications where pH and TDS or pH and EC levels need to be continuously monitored for optimal plant growth. HI 981404N and HI 981405N continuously monitor and display the pH and TDS or pH and EC values of a solution on an easy to read set of dual LCD's. The HI 1286 gel filled pH electrode is replaceable and the BNC connector is protected behind a waterproof sheath. The unique design of the electrode guarantees greater clogging resistance in fertilizer solutions with high concentrations of phosphate, nitrate, etc. TDS measurements are performed using the 4-4-2 conversion factor of 0.7 so you do not need to convert the readings. Both models are equipped with a grounding bar to ensure more accurate pH measurements and longer electrode life. The HI 981404N and HI 981405N are compact and easy to install and use. This makes them ideal for all continuous monitoring applications. 2004 Agricultural Catalog Combined Measurement Monitors & portables SPECIFICATIONS HI 991404 HI 991405 Range pH 0.00 to 14.00 0.00 to 14.00 EC 0 to 3999 µS/cm 0.00 to 19.99 mS/cm TDS 0 to 1999 ppm 0.00 to 10.00 ppt T° 0.0 to 60.0°C or 32.0 to 140.0°F Resolution pH 0.01 0.01 EC 1 µS/cm 0.01 mS/cm TDS 1 ppm 0.01 ppt T° 0.1 °C or 0.1°F Accuracy pH ± 0.05 EC ± 2% F.S. TDS ± 2% F.S. T° ± 0.5°C or ± 1°F Temp. Comp. EC/TDS Automatic, ß adjustable for 0.0 to 2.4%/°C pH Automatic Electrode/probe HI 1293D pH elec. / HI 7630 EC/TDS probe Power Supply External 12 VDC Dimensions 165 x 110 x 35 mm (6.5 x 4.3 x 1.3”) Weight 300 g (10.6 oz) HI 991404 & HI 991405 pH/EC/TDS/Temperature monitors The new Combo Gro’Chek from Hanna has a dual-level backlit LCD to give you instantaneous readings of pH/EC/TDS and Temperature. The microprocessor provides automatic calibration, automatic buffer selection and TDS ratio plus Automatic Temperature Compensation. • • • • • • Waterproof Dual-level backlit LCD Adjustable TDS ratio Adjustable ß Extra large display 12 VDC power supply Installation for in-line applications Water Source HI 9810 Injector pH Electrode EC/TDS Electrode Acid or Fertilizers Extended range pH/EC/TDS meter TDS conversion factor= 0.5 HI 9810 is a portable meter for field measurement of pH, conductivity and TDS in water and solutions. The rugged housing has been specifically designed to be easy to use in the plant or in the field while reducing the number of instruments required for water quality analysis. HI 9810 measures pH from 0.00 to 14.00 with 0.10 resolution. HI 9810 measures conductivity from 0 to 3000 mg/l; 0 to 6000 µS/cm. Calibration has been simplified to one point for both pH and conductivity/TDS modes. The accuracy of your conductivity and TDS measurements will not be in question as HI 9810 is equipped with Automatic Temperature Compensation. No probe changes are required when switching your measured parameter between pH, conductivity and TDS. The specially engineered pH electrode also features a fiber junction and gel electrolyte for faster response and reduced contamination. The very economical price of this meter makes it particularly attractive. SPECIFICATIONS Range Resolution Accuracy (@20°C/68°F) Typical EMC Deviation EC/TDS Conversion Factor Calibration Temp. Compensation Probe Battery Type / Life Environment Dimensions Weight 2004 Agricultural Catalog pH EC TDS pH EC TDS pH EC TDS pH EC TDS HI 9810 0.00 to 14.00 pH 0 to 6000 µS/cm 0 to 3000 mg/l (ppm) 0.10 pH 10 µS/cm 10 mg/l ± 0.20 pH ± 2% F.S. ± 2% F.S. ± 0.10 pH ± 2% F.S. ± 2% F.S. 0.5 mg/l = 1 µS/cm Manual 1 point through trimmer for all parameters Automatic from 0 to 50°C (32 to 122°F) with ß of 2% /°C (EC/TDS only) HI 1285 pH/EC/TDS/°C probe and 1 m (3.3’) cable (included) 1 x 9 V / approximately 150 hours of use 0 to 50°C (32 to 122°F); RH 95% 185 x 82 x 45 mm (7.3 x 3.2 x 1.8”) 520 g (1.1 lb) 16 Combined Measurement Portables HI 9811-0 & HI 9811-5 • • • New features T° measurement on HI 9811-5 model Water resistant body SPECIFICATIONS Range • • Slim version TDS conversion factor = 0.5 pH/EC/TDS measurements in one meter HI 9811 is a portable meter for field measurement of pH, conductivity and TDS in agriculture. This meter is ideal for crops with a higher conductivity requirements. The HI 9811 measures pH from 0 to 14 with 0.1 resolution. The HI 9811 measures conductivity from 0.00 to 6.00 mS/cm and TDS from 0.00 to 3.00 g/l both in hundredths of units. The accuracy of your conductivity and TDS measurements will not be in question as the HI 9811 is equipped with Automatic Temperature Compensation. In addition, the BEPS (Battery Error Prevention System) will alert the user when low batteries could affect the readings. These portable meters use the newly designed replaceable HI 1285 probe. Probe changes are no longer required when switching your measured parameter between pH, conductivity and TDS. pH EC TDS T° Resolution pH EC TDS T° Accuracy pH EC/TDS T° TDS conversion factor Calibration Temp. Compensation Probes included Battery type/life Dimensions Weight HI 9811-0 HI 9811-5 0.0 to 14.0 0 to 6000 µS/cm 0 to 3000 mg/l (ppt) - 0.0 to 70.0°C 0.1 10 µS/cm 10 mg/l - 0.1°C ± 0.1 ± 2% F.S. - ± 0.5°C 0.5 Manual 1 point through trimmer Automatic from 0 to 50°C with ß of 2%/°C (EC/TDS only) HI 1285-0 HI 1285-5 1 x 9 V alkaline, approx. 150 hours of continuous use 165 x 75 x 45 mm (6.5 x 3.0 x 1.8”) 250 g (8.8 oz) HI 9813 series pH/EC/TDS/°C meters This multi-parameter instrument tests for 3 of the most important factors in the growing environment. Calibration is quick and easy with calibration dials. Accuracy is ensured with Automatic Temperature Compensation and the advanced sensor which completely eliminates polarization and oxidation problems. Comes complete with probe. SPECIFICATIONS HI 9813 Range pH 0.0 to 14.0 EC 0.00 to 4.00 mS/cm TDS 0 to 1999 ppm T° Resolution pH 0.1 EC 0.01 mS/cm TDS 1 ppm T° Accuracy pH ± 0.1 EC/TDS ± 0.2% F.S. T° Temp. Comp. Automatic from 0 to 50°C TDS conversion factor Variable, 0.56 to 0.72 Probes included HI 1285-0 pH/EC/TDS probe Battery Life Approx. 150 hours continuous use Dimensions 165 x 75 x 45 mm (6.5 x 3.0 x 1.8”) Weight 250 g (8.8 oz) 17 HI 9813-5 0.0 to 14.0 0.00 to 4.00 mS/cm 0 to 1999 ppm 0.0 to 60.0°C 0.1 0.01 mS/cm 1 ppm 0.1°C ± 0.1 ± 0.2% F.S. ± 0.5°C Automatic from 0 to 50°C Variable, 0.56 to 0.72 HI 1285-5 pH/EC/TDS/°C probe Approx. 150 hours continuous use 165 x 75 x 45 mm (6.5 x 3.0 x 1.8”) 250 g (8.8 oz) HI 9813-6 0.0 to 14.0 0.00 to 4.00 mS/cm 0 to 1999 ppm 0.0 to 60.0°C 0.1 0.01 mS/cm 1 ppm 0.1°C ± 0.1 ± 0.2% F.S. ± 0.5°C Automatic from 0 to 50°C Variable, 0.56 to 0.72 HI 1285-5 pH/EC/TDS/°C probe (Cal Check) Approx. 150 hours continuous use 165 x 75 x 45 mm (6.5 x 3.0 x 1.8”) 250 g (8.8 oz) • • • • • • • All new features Conversion factor adjustable (0.5 - 0.7) 3 Meters in 1 Fast response probe Easy to calibrate Automatic Temperature Compensation Water resistant body 2004 Agricultural Catalog Combined Measurement Portables HI 991300 & HI 991301 pH/EC/TDS/Temperature megameter 4 in 1 meter with waterproof casing Theses multi-parameter instruments test 4 of the most important factors in the growing environment. Calibration is performed at the touch of a button with memorized pH and EC buffers. Accuracy is ensured with Automatic Temperature Compensation and the advanced sensor which completely eliminates polarization and oxidation problems. Beta factor and TDS ratio are user-selectable as is the ability to read in °C or °F. The HI 991300 & HI 991301 come complete with probe and carrying case. SPECIFICATIONS Range pH EC TDS T° Resolution pH EC TDS HI 991300 HI 991301 0.00 to 14.00 0 to 3999 µS/cm 0 to 2000 ppm 0.00 to 20.00 mS/cm 0.00 to 10.00 ppt 0.0 to 60.0°C or 32.0 to 140.0°F 0.01 1 µS/cm 1 ppm 0.01 mS/cm 0.01 ppt 0.1°C or 0.1°F ± 0.1 ± 2% F.S. ± 2% F.S. ± 0.5°C or ± 1°F EC/TDS ratio Selectable from 0.45 to 1.00 (0.50 default); step is of 0.01 unit pH calibration Automatic 1 or 2 points with 2 sets of memorized standard buffers (pH 4.01, 7.01,10.01 or 4.01, 6.86, 9.18) EC/TDS calibration Automatic 1 point at 1382 ppm; Automatic 1 polnt at 6.44 ppt; (conv.=0.5); 1500 ppm (conv.=0.7); 1413 µS/cm (others) (conv.=0.5); 9.02 ppt (conv.=0.7) 12880 µS/cm (others) Temp. Comp. pH Automatic from 0 to 60°C EC/TDS Automatic from 0 to 60°C with a selectable ß from 0.0 to 2.4%/°C (1.9 default); step is 0.1 unit Probe included HI 1288 pH/EC/TDS probe with built-in temperature sensor, DIN connector and 1 m (3.3’) cable Battery type/Life 4 x 1.5 V AAA / approx. 500 hours of continuous use Dimensions 143 x 80 x 38 mm (5.6 x 3.1 x 1.5”) Weight 320 g (11.3 oz) Accuracy T° pH EC TDS T° INFO Soluble salts Measuring soluble salts provides a general indication of nutrient deficiency or excess. Excess soluble salts are very common and generally results from too much fertilizer in relation to the plant’s needs, but inadequate watering and leaching or poor drainage are other causes. Sometimes high soluble salt levels occur when root function is impaired by disease or physical damage. Always check the physical condition of the root system when sampling soil for testing. 2004 Agricultural Catalog 18 Direction for Field Preparations of Soil Samples Nutrient Analysis PREPARING A SOIL SAMPLE FOR ANALYSIS There are several methods available to obtain a soil sample for measurement. The objective is to find a method you can use that will give you consistent results. Below we have indicated one method commonly used in agriculture. In all cases, the goal is to prepare a sample which is as clean as possible. Any coloration or turbididty in the samples will adversely affect the ability of the unit to give an accurate reading. 2 : 1 Ratio method + = Step 1. Take a sample of soil and mix it with distilled water, 85 g (3 oz) of soil with 170 g (6 oz) of distilled water. Then let the mixture stand for approximately 30 minutes in order to stabilize. Step 2. Filter the solution with a medium filter (C 0002-12.5) through a funnel into a clean cup. If the filtrate is not clear, run through a clean filter again until you have a translucent solution. Step 3. If your solution is not translucent, use the Activated Charcoal included in the kit, mix with the solution, and filter one more time. This should give you a translucent liquid, and you will be ready to begin your analysis procedures. Ideally, you should filter enough of the solution to have an end result of 50 ml of liquid. Step 4. Follow the instructions in the operators manual provided with your meter to mix and measure your samples to determine the analysis of the parameter you are measuring. 19 2004 Agricultural Catalog Dissolved Oxygen Measurement Meters HI 93732N • • • • Lifetime light source Maintenance free Easy to operate Cost effective SPECIFICATIONS HI 93732N Range 0.0 to 10.0 mg/l (ppm) Resolution 0.1 mg/l Accuracy (@20°C/68°F) ± 0.2 mg/l ± 3% of reading Typical EMC Deviation ± 0.1 mg/l Light Source Light Emitting Diode @ 430 nm Light Life Life of the instrument Light Detector Silicon Photocell Battery Type / Life 1 x 9 V / approx. 40 hours of continuous use. Auto shut-off after 10 minutes of non-use Environment 0 to 50°C (32 to 122°F); RH 95% Dimensions 180 x 83 x 46 mm (7.1 x 3.3 x 1.8”) Weight 290 g (10 oz) Method Modified Winkler method. The reaction between Dissolved Oxygen and the reagent causes a yellow tint in the sample. The Hanna HI 93732N utilizes a sophisticated custom microprocessor and a modified Winkler method to measure dissolved oxygen accurately and quickly. Measurements are made in a few short steps that can be performed by technical and non-technical operators alike. In fact, all you need to do is insert a cuvet containing your sample into the meter and press ZERO. This will calibrate the meter to your sample in seconds. Then add a few drops of the reagents to the sample to generate a color whose intensity depends on the D.O. content. Place the reacted sample back in the meter and the instrument will do the rest of the work for you! HI 93732N will display the D.O. concentration in tenths of ppm in clear digits and on a large LCD. No need to worry about temperature changes, membrane status or salinity variations. Ease of use and accuracy are not the only qualities of the Hanna HI 93732N. In fact, you will be pleasantly surprised to know that HI 93732N with all its benefits is priced at a fraction of the conventional D.O. meters on the market. HI 9142 • • INFO Waterproof Simple to use Waterproof Dissolved Oxygen meter for field use HI 9142 is a rugged, waterproof meter that solves the common problems of field use. It is very simple to use: calibration is performed with HI 7040 zero oxygen solution while 100% calibration is done in the air. The polarographic probe (HI 76407/4) will take accurate measurements to 0.3 ppm in minutes and is supplied with a 4 m (13') cable that allows measurements to be taken even in hard to reach places. For applications that require longer probe cables, the HI 76407/10 and HI 76407/20 probes with a 10 m (33') or 20 m (67') cable are available. The conic shape of the probe allows it to be used in BOD5 measurements making it a truly versatile instrument. SPECIFICATIONS HI 9042 Range 0.0 to 19.9 mg/l (ppm) Resolution 0.1 mg/l Accuracy ± 1.5% F.S. Calibration Manual 1 or 2 points (zero & slope) Temp. Comp. Automatic Battery Life Approx. 500 hours continuous use. Dimensions 196 x 80 x 60 mm (7.7 x 3.1 x 2.4”) Weight 425 g (15 oz) 2004 Agricultural Catalog Measuring Dissolved Oxygen Oxygen meters are used to determine the quantity of dissolved oxygen in liquids. Two measurement scales are commonly utilized: parts per million (ppm); or the percentage saturation (%), which is defined as the percentage of oxygen dissolved in 1 liter of water. It is necessary to determine the quantity of dissolved oxygen present in water because it is an indicator of water quality. It is therefore important to monitor civil and industrial waste water where low concentrations indicate pollution. Applications Oxygen meters are used for measuring and monitoring the oxygen content at the various points in the water circuit of steam boiler installations. Another application of oxygen meters is in the prevention of metal corrosion, such as in heating systems, where one of the factors affecting the rate of corrosion is the percentage of oxygen present. Another very important application is in fish farming and hydroponics, where oxygen levels should be continuously monitored both to attain optimal reproduction and growth, and to prevent high mortality caused by low oxygen. Nuclear power stations are also suitable for oxygen measurement of their heavy water. 20 Dissolved Oxygen Measurement Meters HI 8043 • • Low battery indicator Temperature compensation circuitry The HI 8043 is a versatile D.O. meter developed for use in the school laboratory. A common 9 volt battery supplies the unit with up to 100 hours of continuous power making it truly portable. There is also a low battery warning that helps eliminate the possibility of taking an erroneous reading due to low power. The simplicity of this meter is its greatest asset. Simply select the O2 mode and the polarographic probe will supply you with accurate dissolved oxygen measurements in mg/l. Switch the dial to °C to show the temperature readings. The STB mode is particularly useful to keep the current flowing through the probe which is continuously polarized and ready for use. HI 91410 HI 91410 is a portable, printing D.O. meters designed for continuous monitoring and recording at selectable time intervals. The lowpower printer uses regular paper that is easily sourced and will not fade over time. HI 91410 combines printing functions with the capability to log measurements. In addition to supplying the user with instant printouts of D.O., it also provides datalogging facilities that will store up to 8000 readings. These measurements can be scrolled through at any time, printed or even transferred to a computer system by the optional HI 9200 infrared transmitter. This infrared connection is important in humid environments where a standard RS232 plug on a meter could become damaged. The meter automatically compensates for two very important parameters: altitude from 0 to 1900 meters (6230') and salinity from 0 to 40 g/l. SPECIFICATIONS Range Resolution Accuracy Calibration Temp. Comp. Altitude Comp. Salinity Comp. Battery Life Dimensions Weight 21 HI 9143 0.00 to 45.00 mg/l O2; 0.0 to 300.0 % saturation O2 0.0 to 50°C 0.01 mg/l O2; 0.1 % saturation O2; 0.1°C ± 1.5% F.S. mg/l O2; ± 1.5% F.S. % saturation O2; ± 0.5°C Automatic in air at 100% Automatic 0 to 1900 m (0 to 6230’), 100 m (328’) resolution 0 to 40 g/l; 1 g/l resolution Approx. 200 hours continuous use. Socket for 12 VDC power supply 196 x 80 x 60 mm (7.7 x 3.1 x 2.4”) 425 g (15 oz) SPECIFICATIONS HI 8043 Range D.O../°C 0.0 to 19.99 mg/l/0.0 to 50.0°C Resolution D.O./°C 0.01 mg/l/0.1°C Accuracy D.O. ± 1.5% F.S. (@20°C/68°F) °C ± 0.5°C Typical EMC D.O. ± 1.5% F.S. Deviation °C ± 1°C Calibration Manual at 2 points (zero & slope) Temperature Compensation Automatic from 0 to 30°C (32 to 86°F) Probe HI 76401 polarographic D.O. probe with 3 m (10’) cable (included) Battery Type / Life 1 x 9 V / approximately 100 hours of continuous use Dimensions 180 x 83 x 40 mm (7.1 x 3.3 x 1.6”) Weight 370 g (13 oz) with probe SPECIFICATIONS Range HI 91410 0.00 to 19.99 mg/l 0.0 to 50.0 Resolution 0.01 mg/l 0.1 Accuracy ± 1.5% F.S. (@20°C/68°F) ± 0.5 Calibration Automatic in air at 100% Temperature Comp. Automatic from 0 to 30°C (32 to 86°F) Altitude Comp. 0 to 1900 m (0 to 6230’) / 100 m resolution Salinity Comp. 0 to 40 g/l / 1 g/l resolution Probe included HI 76407/4 polarographic D.O. probe with 4 m (13’) cable Printer Low power impact type-belt, 14 characters per line using 38 mm plain paper (HI 710034) Printing & Log. Intervals Selectable from 1, 2, 5, 10, 15, 30, 60, 120 and 180 minutes Computer Interface HI 9200 infrared transmitter through RS232 serial port Power Supply 4 x 1.5V AA batteries; approximately 70 hours of continuous use with rapid printing interval. Auto shut-off after 4 hours. Power plug for 12 VDC supply. Dimensions 220 x 82 x 66 mm (8.7 x 3.2 x 2.6”) Weight 500 g (18 oz); kit: 1.7 kg (3.8 lb) 02 °C 02 °C 02 °C Waterproof, extended range Dissolved Oxygen meter. HI 9143 The HI 9143 is designed for outdoor applications, especially wastewater treatment and fish farming. Simple on-site calibration requires no chemical solutions. Just expose the probe to air and press the CAL button. In a few minutes, the meter is calibrated and ready to use. The HI 9143 measures and displays O2 from 0 to 300%, 0 to 45 mg/l and temperature from 0 to 50 °C. 2004 Agricultural Catalog Light Intensity Measurement Lux meter HI 97500 Lux meter Portable Lux Meter for rapid light measurements in a water resistant case The HI 97500 portable Lux Meter from Hanna Instruments has been designed for simplicity of use in taking rapid light measurements. The HI 97500 is provided with a light sensor connected by a flexible coaxial cable which allows remote, stable and optimum position measurement of light, without any interference of the operator. The meter makes it possible to choose among three measurement ranges by simply pressing the RANGE key. • Three measurement ranges • Light sensor attached to 1.5 meter coaxial cable • Rugged, water resistant case • Low battery indicator SPECIFICATIONS Range (KLux) Resolution (KLux) Accuracy Calibration Sensor LUX METER - HI 97500 0.001 to 1.999; 0.01 to 19.99; 0.1 to 199.9 0.001; 0.01; 0.1 ± 6% of reading ± 2 digits Factory calibrated Human-Eyes-Response silicon photodiode with 1.5 m fixed cable Approx. 200 hours cont. use. Auto-off after 7 min. of non-use 164 x 76 x 45 mm (6.5 x 3 x 1.8”) 170 g with sensor Battery Life Dimensions Weight The HI 97500 Lux Meter is housed in a rugged waterproof case for trouble-free outdoor measurements. Plant Light Requirements Light provides the energy source needed for plants to manufacture food (photosynthesis). The amount of light is commonly measured in foot-candles (ft-c) or lux. Plants differ greatly in their light intensity requirements. Indoor plants are often classified by the amount of light necessary for growth: Light Intensity Quality of light is very important in the workplace, schools, greenhouses, fish farms and public buildings. Too little light (or luminous intensity) affects the quantity and quality of performance of both people and crops. Hanna's light meter uses special optic filters to match the spectral sensitivity of the human eye. • Low (minimum 1.1 Klx, .8 to 2.1 preferred for good growth) • Medium (minimum 1.1 to 1.6 Klx, 2.1 to 5.4 preferred) Luminous intensity is measured and reported in footcandles (ft-c) or in lux (lx). Light meters are commonly referred to as lux meters. One lux is equal to one lumen per square meter and one foot-candle is equal to one lumen per square foot. To convert measurements use the following formulae: • High (minimum 1.6 to 10.8 Klx, 5.4 to 10.8 preferred) • Very high (minimum 10.8 Klx, 10.8 + preferred) About 1.1 Klx for 12 hours per day are necessary simply to maintain plant quality for one year and at least 2.1 Klx for 12 hours per day are necessary for foliage plants to manifest any benefit from fertilization. foot-candle = lux x 0.0929 lux = foot-candle x 10.764 While lack of sufficient light results in poor plant growth, too much light can also be harmful. Shade plants cannot tolerate excessively high light levels. When a plant receives too much direct light, the leaves bleach or scald, sometimes dying. This often happens after moving a plant outdoors in direct light. Any changes in light intensity should be gradual. Hanna's light measuring sensor is a photo diode that converts incident light into an electronic signal that is read and displayed on the meters LCD as Klx which is 1,000 lx. So multiply the reading by 92.9 to get the measurement in foot candles. INFO Light intensity Common examples of light intensities Full moon Street lighting Workspace lighting Surgery lighting Sunshine .001 Klx .01 Klx .1 - 1 Klx 10 Klx 100 Klx 1 lx 10 lx 100 - 1,000 lx 10,000 lx 100,000 lx .0929 ft-c .929 ft-c 9.29 - 92.9 ft-c 929 ft-c 9,290 ft-c 2004 Agricultural Catalog Light measurements are important to verify the life span of grow lights, positioning of plants in greenhouse settings. 22 Nutrient Management Chemical test kits Nutrient management Nutrient management is rapidly becoming one of, if not the most important issue facing agriculture today. Monitoring all aspects of input and output from farm lands, greenhouse sites and recreational facilities will be critical for long term operation. Using Hanna Instruments test kits, single or multiple parameter photometers, makes the monitoring precise, easy and very economic. Each test kit comes with thorough instructions and everything necessary to perform quick and easy tests. Ask us to customize a kit tailored to your needs to get the most value for your money. PARAMETER Acidity (HI 3820) RANGE(S) 0-100 mg/l 0-500 mg/l Alkalinity (HI 3811) Titration 0-100 mg/l 0-300 mg/l Alkalinity, Total (HI 38014) Titration 0-500 gpg Ammonia (HI 3824) Colorimetric 0-2.5 mg/l Boron (HI 38074) Titration 0-5.0 mg/l Carbon Dioxide Titration 0-10.0 mg/l (HI 3818) Titration 0-50.0 mg/l Titration 0-100 mg/l Chloride (HI 3815) Titration 0-100 mg/l 0-1000 mg/l Chloride (HI 38015) Titration 500-10.000 mg/l Titration 5.000-100.000 mg/l Gypsum Requirement & Titration GR: 0-213 metric ton /ha Exchangeable Sodium (HI 38083) ES: 0-56.4 meq/100g soil Hardness (HI 3812) Titration 0-30 mg/l 0-300 mg/l Hardness (HI 3840) Titration 0-150 mg/l Hardness (HI 3841) Titration 40-500 mg/l Hardness (HI 3842) Titration 400-3000 mg/l Iron & Total Hardness Colorimetric Fe: 0-5 mg/l (HI 3889) Titration 40-500 mg/l Iron (HI 3834) Colorimetric 0-5 mg/l Nitrate (HI 3874) Colorimetric 0-50 mg/l Nitrate, Irrigation Water Checker Disc IW: 0-50 mg/l & Soil (HI 38050) Checker Disc Soil: 0-60 mg/l Nitrite (HI 3873) Colorimetric 0-1 mg/l Oxygen, Dissolved Titration 0-10 mg/l (HI 3810) Titration 0-5 mg/l Ozone (38054) Checker Disc 0-2.3 mg/l pH (HI 38058) Checker Disc 4.0-10.0 pH Salinity (HI 3835) Titration 0-40 g/kg Sodium Absorption Ratio DiST 4 + test kit > 0 meq/l (SAR) (HI 38078) Calcium+ Magnesium Zinc, HR Checker Disc 0-4.0 mg/l (HI 38076) Checker Disc 0-20.0 mg/l HI 3895- Agricultural Multiparameter Test Kit Nitrogen Colorimetric traces, low, med, high Phosphorous Colorimetric traces, low, med, high Potassium Turbidimetric traces, low, med, high pH Turbidimetric from 4 to 9 pH (1 pH increments) HI 3896- Agricultural Multiparameter Test Kit Nitrogen Colorimetric traces, low, med, high Phosphorous Colorimetric traces, low, med, high Potassium Turbidimetric traces, low, med, high pH Turbidimetric from 4 to 9 pH (1 pH increments) 23 METHOD Titration CHEMICAL METHOD Methyl-orange Phenolphthalein Phenolphthalein Bromophenol blue Bromophenol blue Nessler Boric Acid Phenolphthalein Phenolphthalein Phenolphthalein Mercuric Nitrate Mercuric Nitrate Silver Nitrate Titration Calcium Sulfate Calcium Sulfate EDTA EDTA EDTA EDTA EDTA Phenanthroline EDTA Phenanthroline Cadmium reduction Cadmium reduction Cadmium reduction Sulfanilamide Modified Winkler Modified Winkler DPD pH indicators Mercuric nitrate Titration # TESTS WEIGHT 110 total 32 oz (910 g) 110 total 100 25 100 16 oz (460 g) 13 oz (363 g) 6.3 oz (180 g) 27.5 oz (780 g) 110 total 16 oz (460 g) 110 total 16 oz (460 g) 100 total 23.4 oz (664g) 100 total 31 oz (883 g) 100 total 50 50 50 50 50 50 100 16 oz (460 g) 4.2 oz (120 g) 4.2 oz (120 g) 4.2 oz (120 g) 9 oz (260 g) 5 oz (145 g) 5.4 oz (156 g) 100 total 100 36 oz (1026 g) 5.6 oz (160 g) 110 total 100 300 110 32 oz (910 g) 34 oz (966 g) 7.5 oz (215 g) 16 oz (460 g) 100 27.6 oz (785 g) Zincon Zincon 100 22.8 oz (647g) Ned Ascorbic acid Tetraphenylborate pH indicators 10 10 10 10 3.7 oz (105 g) Ned Ascorbic acid Tetraphenylborate pH indicators 25 25 25 25 23.3 oz (660 g) 2004 Agricultural Catalog Nutrient Management Single/dual parameter Ion Specific Meters Single or Dual Parameter Ion Specific Meters SPECIFICATIONS TEST Ammonia (HI 93700) (ER) Ammonia (HI 93715) (MR) Ammonia (HI 93733) (HR) Chlorine, Free & Total (HI 93734) Copper (HI 93702) (HR) Iron (HI 93721) (HR) Manganese (HI 93709) (HR) Nickel (HI 93740) (LR) Nitrate (HI 93728) Nitrite (HI 93708) (HR) Oxygen, Dissolved (HI 93732N) Phosphate (HI 93717) (HR) Phosphorus (HI 93706) Potassium (HI 93750) Sulfate (HI 93751) Zinc (HI 93731) Calcium and Magnesium (HI 93752) (HR) RANGE 0.00-3.00 mg/l 0.00-9.99 mg/l 0.0-50.0 mg/l 0.00-9.99 mg/l (F. & T.) 0.00-5.00 mg/l 0.00-5.00 mg/l 0.0-20.0 mg/l 0.000-1.000 mg/l 0.0-30.0 mg/l 0-150 mg/l 0.0-10.0 mg/l 0.0-30.0 mg/l 0.0-15.0 mg/l 0.00-50.0 mg/l 0-150 mg/l 0.00-3.00 mg/l 0-150 mg/l Mg 0-400 mg/l Ca METHOD Nessler/470 nm Nessler/470 nm Nessler/470 nm DPD Bicinchoninate/555 nm Phenantroline/470 nm Periodate Oxidation/555 nm PAN/555 nm Cadmium Reduction/555 nm Ferrous Sulfate Modified Winkler/430 nm Amino Acid/470 nm Amino Acid/470 nm Turbidimetric Turbidimetric/470 nm Zincon Calmagite Oxalate ACCURACY ± 0.04 mg/l ± 4% of reading ± 0.05 mg/l ± 5% of reading ± 0.5 mg/l ± 5% of reading ± 0.03 mg/l ± 3% of reading ± 0.02 mg/l ± 4% of reading ± 0.04 mg/l ± 2% of reading ± 0.2 mg/l ± 3% of reading ± 0.010 mg/l ± 5% of reading ± 0.5 mg/l ± 10% of reading ± 4 mg/l ± 4% of reading ± 0.2 mg/l ± 3% of reading ± 1 mg/l ± 4% of reading ± 0.3 mg/l ± 4% of reading ± 1 mg/l ± 5% of reading ± 1 mg/l ± 5% of reading ± 0.03 mg/l ± 3% of reading ± 3 mg/l ± 3% of reading ± 10 mg/l ± 5% of reading • • • • • Lightweight and portable Quick and simple to use Long battery life Lab grade accuracy Economical tests INFO SPECIFICATIONS FOR DUAL AND SINGLE PARAMETER ISMS Light Source Light Emitting Diode @ 470 nm Light Detector Silicon Photocell Battery Life Approx 40 hours continuous use Dimensions 180 x 83 x 46 mm (7.1 x 3.3 x 1.8”) Weight 290 g (10 oz) PRODUCTS HI 93733-01 (HR) HI 93734-01 HI 93702-01 (HR) HI 93721-01 (HR) HI 93709-01 (HR) HI 93740-01 (LR) HI 93728-01 HI 93708-01 (HR) HI 93732-01 HI 93717-01 (HR) HI 93706-01 HI 93750-01 HI 93751-01 HI 93731-01 HI 93752-01 (HR) 2004 Agricultural Catalog mg/l = ppm LR = Low Range MR = Medium Range HR = High Range nm = nanometers REAGENTS Ammonia Free & total Chlorine Copper Iron Manganese Nickel Nitrate Nitrite Dissolved Oxygen Phosphate Phosphorus Potassium Sulfate Zinc Magnesium and Calcium NUMBER OF TESTS 100 tests 100 tests 100 tests 100 tests 100 tests 50 tests 100 tests 100 tests 100 tests 100 tests 100 tests 100 tests 100 tests 100 tests 100 tests 24 Nutrient Management Grow Master C 215 - Grow Master C 215 is a practical instrument made to measure nutrients commonly present in fertilizer-enriched solutions. This convenient photometer measures ammonia, phosphorus, nitrate and potassium in three distinct ranges of low, medium and high concentrations. This way accuracy is maximized for each nutrient and for every concentration. Nitrogen, Phosphorus, Potassium and Ammonia meter • • • • • SPECIFICATIONS Light Source Light Detector Battery Life Dimensions Weight Thanks to the low cost per test and simplicity of the operations, you no longer need to send off your samples and wait for the results to come back. Using the C 215, you can test the presence and strength of nutrients right on the spot. This can translate itself into a substantial savings and improved yield. C 215 has been engineered to run on battery power as well as the mains. The C 215 comes complete with a 9-volt battery and a 12 VDC adapter. Add to this the unit’s lightweight and you have a bench/portable meter that is just at home in the field as in the horticulturist’s lab. Accurate 4 Parameters in 1 meter Three ranges for each parameter Easy to use Economical tests C 215 Light Emitting Diode @ 470 nm Silicon Photocell Approx 40 hours continuous use 230 x 165 x 70 mm (9.0 x 6.5 x 2.8”) 640 g (22.6 oz) SPECIFICATIONS TEST Ammonia LR Ammonia MR Ammonia HR Nitrate LR Nitrate MR Nitrate HR Phosphorus LR Phosphorus MR Phosphorus HR Potassium LR Potassium MR Potassium HR C 215 RANGE 0.0-10.0 mg/l 0.0-50.0 mg/l 0-100 mg/l 0.0-30.0 mg/l 0-150 mg/l 0-300 mg/l 0.0-10.0 mg/l 0.0-50.0 mg/l 0-100 mg/l 0.0-50.0 mg/l 10-250 mg/l 20-500 mg/l METHOD Nessler Nessler Nessler Cadmium Reduction Cadmium Reduction Cadmium Reduction Amino Acid Amino Acid Amino Acid Turbidimetric Turbidimetric Turbidimetric ACCURACY ± 0.1 mg/l ± 4% of reading ± 0.5 mg/l ± 4% of reading ± 1 mg/l ± 4% of reading ± 1 mg/l ± 8% of reading ± 5 mg/l ± 8% of reading ± 10 mg/l ± 8% of reading ± 0.5 mg/l ± 4% of reading ± 2.5 mg/l ± 4% of reading ± 5 mg/l ± 4% of reading ± 3.0 mg/l ± 7% of reading ± 15 mg/l ± 7% of reading ± 30 mg/l ± 7% of reading INFO Plant Nutrition The three elements that are most needed by plants are nitrogen (N), phosphorous (P) and potassium (K). This is the reason why they are called macronutrients and should be given to plants. Nitrogen is indispensable for the plant’s life and is a key factor in fertilization. Nitrogen allows the development of the vegetative activity of the plant, in particular, causes lengthening of trunks and sprouts and increases the production of foliage and fruits. An excess of nitrogen weakens the plants’ structure creating an unbalanced relationship between the leaves and the stalks. In addition, the plant becomes less resistant to diseases. 25 Phosphorous is an important element in the composition of DNA and RNA, the regulators of the energetic exchange (ATP & ADP), as well as the reserve substances in seeds and bulbs. It contributes to the formation of buds, roots, blooming, and lignification. A lack of phosphorous results in: stifling of plant, slow growth, a reduction of production, smaller fruits and a lower expansion of the roots. Even if Potassium is not a constituent of important compounds, it plays a remarkable role in many physiological activities like the control of cellular turgor and the accumulation of carbohydrates. It increases the size of fruits, their flavor, as well as yielding a positive effect on the color and fragrance of flowers. Potassium also makes plants more resistant to disease. 2004 Agricultural Catalog Honey Color Analysis Analyzer & refractometer C 221 - Honey color analyzer The C 221 portable microprocessor analyzer measures the percent light transmittance of honey compared to analytical reagent grade glycerol. The transmittance value allow identification of the honey Pfund grade. The instrument directly displays the measurement result expressed in mm Pfund. Measurements are made using matched square optical cuvets having a 10 mm light path. Display codes aid the user in routine operations. The C 221 features an auto shut-off feature that will turn the instrument off after 10 minutes of non- use. The companion Honey Refractometer for measuring water content is rugged and simple to use with easily identifiable radings. This high precision refractometer measures 12 27% water content. SPECIFICATIONS Range Resolution Accuracy C 221 0 to 150 mm Pfund 1 mm Pfund ± 2 mm Pfund Honey color varies naturally in a wide range of tonalities, ranging from light yellow to amber, dark amber and black in extreme cases. Sometimes green or red hues may occur. Color of untreated honey depends on botanical origin: for this reason color is very important for definition and commercial classification fo monofloral honeys. Honey darkens with age, and other changes in color may result from beekeeper’s interventions and from different ways of conservation (e.g.: use of old honeycombs, contact with metals, high temperatures, exposure to light, etc.). The primary characteristic for commercial honey classification is color. Color classes are expressed in millimeters (mm) Pfund grades, compared to an analytical grade Glycerol Standard Reference. COLOR STANDARDS Extra White White Golden Light Amber Dark Amber Dark CLASSIFICATION 13 or less 13 to 30 34 to 50 50 to 85 85 to 114 More than 114 2004 Agricultural Catalog 26 Maple Syrup Color Analysis Maple syrup color analyzers HI 95759 & HI 95760 Maple syrup grading portable meters The HI 95759 and HI 95760 handheld, portable maple syrup transmittance analyzers are high precision, USDA (HI 95759) or Canada Federal and Quebec (HI 95760) compliant photometers that bring judging “by eye” to an end. The three-button operation and easy-to-read LCD makes these meters ideal in the field. Both meters read in percent transmittance (grades and equivalent below) and provide a digital readout with a precision of ± 1%. • • • • SPECIFICATIONS Range Resolution Accuracy Light Source Dimensions Weight User calibration Display codes Auto shut-off Rugged kit included HANNA MAPLE METERS 0.0 to 100.0% transmittance 0.1% transmittance ± 1% @ 75.0% transmittance Tungsten lamp with narrow band interference filter @ 560 nm 180 x 83 x 46 mm (7.1 x 3.3 x 1.8) 290 g (10 oz) Our new maple meters measure the percent light transmittance of maple syrup as compared to analytical reagent glycerol. The transmittance value allows identification of syrup quality class. Measurements are performed by using matched square optical cuvets having a 10 mm light path. Display codes aid the user in routine operations. MAPLE SYRUP GRADE DESIGNATION United States Canada USDA Federal & Quebec 75.0 to 100.0 60.5 to 74.9 44.0 to 60.4 27.0 to 43.9 Less than 27.0 27 Grade A Light Amber Grade A Medium Amber Grade A Dark Amber Grade B for reprocessing Substandard No. 3 Dark No. 1 Extra Light No. 1 Light Grade A No. 1 Medium Grade A No. 2 Amber 2004 Agricultural Catalog Thermometers & Hygrometers Testers SPECIFICATIONS Range Resolution Accuracy Probe Battery Life Dimensions Weight HI 98601 - Hygrocheck HYGROCHECK - HI 98601 10.0 to 90.0% RH 0.1% RH ± 3% F.S. Thin Film Polymer Capacitor (included) Approx. 100 hours continuous use 180 x 30 x 15 mm (7.1 x 1.2 x 0.6”) 62 g (2.2 oz) Relative Humidity Tester Now the grower can have accurate readings in a pocket sized tester! The Hygrochecks large LCD can be seen from any angle. Housed in rugged ABS plastic, the Hygrocheck uses Hanna Instruments Thin Film Polymer Capacitor Sensor. • Large LCD • Pocket sized • Common sense construction Checktemp®4 - HI 151 series • • • Thermometer with folding penetration thermistor probe The Checktemp® 4 gives you practical solutions to temperature measurement for food service. As you unfold the stainless steel probe, the Checktemp®4 automatically turns ON and immediately performs a calibration test. This unique Hanna feature, Cal-Check, provides you the security of knowing you have accurate measurements. Cal-Check lets you know if your battery level is too low or if your thermometer requires recalibration. Ergonomic and easy to carry Large LCD Cal-Check feature SPECIFICATIONS Range Resolution Accuracy Probe Battery Life Dimensions Weight • • Auto shut-off °C model available HI 151-00 / HI 151-001 HI 151-01 / HI 151-011 -50 to 220°C -58.0 to 428°F 0.1°C (-50.0 to 199.9°C) 0.1°F (-58.0 to 199.9°F) 1°C (200 to 220°C) 1°F (200 to 428°F) ± 0.4°C / ± 1% F.S. (outside) ± 0.8°F / ± 1% F.S. (outside) Stainless steel, penetration 117 x 3.5 mm (6.75 x .187”) Approx. 25,000 hours continuous use 165 x 50 x 20 mm (6.5 x 2 x 1”) 100 g (3.6 oz) A Factory Calibration Certificate is available. Ask your sales associate. INFO Factory Calibration Certificates Checktemp®1 Your thermometer will be calibrated against a NIST standard and a certificate will be issued. HI 98510 Thermometer with remote probe This highly accurate thermometer is equipped with Hanna’s unique calibration device which allows the user to ensure that the instrument is calibrated accurately. The 3-foot cable is ideal for checking temperature in hard to reach places. • • • • 3-foot probe cable Calibration check feature (Cal-Check) Long battery life °C model available SPECIFICATIONS Range Resolution Accuracy Probe Battery Life Dimensions Weight HI 98509 - HI 98511 -50.0 to 150.0°C 0.1°C HI 98510- HI 98512 -58.0 to 302°F 0.1°F (-58.0 to 199.9°F) 1°F (200 to 302°F) ± 0.3°C, ± 0.5°C (outside) ± 0.5°F, ± 1°F (outside) Stainless steel with 3-foot cable Approx. 3000 hours continuous use 106 x 58 x 19 mm (4.2 x 2.2 x 0.7”) 80 g (2.8 oz) A Factory Calibration Certificate is available. Ask your sales associate. 2004 Agricultural Catalog INFO Hanna’s exclusive Cal-Check feature How do you know when the reading on any thermometer is correct? You could make an ice point or slurry. Even then there could be several degrees difference in the real and the theoretical or perceived temperatures. With our exclusive Cal-Check feature, you do not need to waste time preparing for and making these tests, Cal-Check can do it for you. You can check the accuracy and deviation of your thermometer at any time during its life. This way, you are always sure about the accuracy of your readings and if necessary, can manually compensate for any deviation in calibration. 28 Thermometers & Hygrometers Testers HI 145 series Soil thermometer The HI 145 series was designed to measure soil temperature quickly and accurately up to depths of 12 inches. Equipped with a calibration check feature, the user can be assured that each reading is accurate. The T-shaped design and large LCD make the HI 145 easy to spot measure or leave in place. • • • • SPECIFICATIONS Range Resolution Accuracy Probe Battery type / life Dimensions Weight 12” stainless probe 5” stainless probe T-shaped with easy-to-read display Available with 5” or 12” probe °C model available Cal-Check feature HI 145-00 HI 145-20 HI 145-01 HI 145-30 -50.0 to 220°C -58.0 to 428°F 0.1°C (-50.0 to 199.9°C), 1°C (200 to 220°C) 0.1°F (-58.0 to 199.9°F), 1°F (200 to 428°F) ± 0.3°C (-20 to 90°C)/± 0.4% F.S. (outside) ± 0.5°F (-4 to 194°F)/± 0.4% F.S. (outside) 5” stainless steel 12” stainless steel 5” stainless steel 12” stainless steel 1 x 1.5V AAA / Approx. 10,000 hours continuous use / Auto shut-off after 8 minutes 92 x 165 x 38 mm (3.6 x 6.5 x 1”) 92 x 340 x 38 mm (3.6 x 13.4 x 1.5”) 65 g (2.4 oz) Checkfridge INFO Plant Stress Ideal soil temperature is a constant 70°F for most plants.You should take readings during peak sunlight hours. Compost Temperature Maintain a minimum pile temperature of 131°F for 3 days to destroy weed seeds or plant pathogens. Seed Beds Proper soil temperature for seed germination allows for higher sprouting in seed beds. 29 HI 147 Temperature monitor with magnetic backing & remote thermistor sensor on a 1 meter cable HI 147 is the ideal thermometer when you need accurate, reliable internal temperature monitoring from the outside. The HI 147 incorporates Hanna’s unique Cal-Check feature which allows the user to calibrate the thermometer internally. A low battery warning “ERR” message completes the HI 147’s rich features. • • • • Magnetic backing Cal-Check feature Large easy-to-read display °C model available SPECIFICATIONS Range Resolution Accuracy Probe Battery Life Dimensions Weight CHECKFRIDGE - HI 147-00 CHECKFRIDGE - HI 147-01 -50.0 to 150.0°C -58.0 to 302°F 0.1°C 0.1°F (-20.0 to 199.9°F), 1°F (200 to 302°F) ± 0.3°C (-20 to 90°C)/± 0.5°C (outside) ± 0.5°F (-4 to 194°F)/ ± 1°F (outside) Stainless steel, 40 x 5 mm (1.5 x .187”), 1 m silicon cable Approx. 3 years 92 x 36 x 28 mm (3.625 x 1.25 x 1”) 60 g (2.4 oz) A Factory Calibration Certificate is available. Ask your sales associate. 2004 Agricultural Catalog Thermometers & Hygrometers Professional meters HI 935005S Compost thermometer The HI 935005 is a hand-held waterproof thermometer that uses a K-type sensor together with an advanced microprocessor to deliver accurate temperature measurement with an extraordinary 1600 hour battery life. The new dual-level LCD displays current temperature along with the minimum and maximum extremes achieved during the session. Battery level indication with low battery warning and error prevention furnishes this meter with advanced battery management functions. A HOLD button allows the user to record readings. The °C/°F button instantly switches between the Celsius and Fahrenheit ranges. A wide variety of interchangeable probes are available to meet specific applications. • Designed for many types of boilers and cookers • 18” adjustable probe SPECIFICATIONS Range Resolution HI 935005 HI 935005 HI 935005S -50.0 to 199.9°C (-58.0 to 399.9°F) 200 to 1350°C (400 to 2462°F) 0.1°C (up to 199.9°C) / 1°C (outside) / 0.1°F (up to 399.9°F) / 1°F (outside) Accuracy Probe Battery type / life Dimensions Weight ± 0.2% Full Scale, for one year, excluding probe error 18” K-type thermocouple (included) 3 x 1.5V AA / approx. 1600 hours of continuous use. 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”) 235 g (8.3 oz) HI 766TR2 HI 766SPEA HI 9053 - HI 9055 • • • • • Use: semisolids, liquids. MAX temperature: 250°C / 482°F Response time (90% of final value): 10 sec. Probe length: 1000 mm (39.3”); dia 10 mm (0.4”) Tube in stainless steel 18 inch K-type thermocouple probe. Complete with adjustable bracket to fit in many type of boilers and cookers. Ideal to use with HI 9053, HI 9055 & HI 935005S. • Alarm functions • HOLD function • High temperature range HI 9053 and HI 9055 are microprocessor-based thermocouple thermometers that supply the user with reliable readings in the higher temperature ranges. These meters are housed in a rugged ABS casing that protects them for years. The powerful microprocessor provides several added functions to the performance of these meters. HI and LO keys allow the user to recall the highest and lowest readings taken. A MEM HOLD and MR button makes it possible to freeze a reading on the display, and then recall it at a later time. The alarm functions can be set at a high and low point to alert the user in the event of an out-of-range condition. The built-in acoustic alarm and temperature differentials are valuable features for all engineering tests and process monitoring. The HI 9053 monitors temperature on the Centigrade scale and the HI 9055 measures in the Fahrenheit range. 2004 Agricultural Catalog SPECIFICATIONS Range Resolution Accuracy Probe Battery type/life Dimensions Weight HI 9053 HI 9055 -50.0 to 150.0°C -58.0 to 199.8°F -50 to 950°C -58 to 1742°F 0.1°C (-50.0 to 150.0°C) 0.2°F (-58.0 to 199.8°F) 1°C (-50 to 950°C) 1°F (-58 to 1742°F) ± 0.5% F.S. for one year, excluding probe error K-type thermocouple (optional) 1 x 9V / approx. 500 hours of continuous use 180 x 83 x 40 mm (7.1 x 3.3 x 1.6") 350 g (12.4 oz) 30 Thermometers & Hygrometers Professional meters SPECIFICATIONS HI 99550-0 HI 99550-01 Range -10 to 300°C -14 to 572°F Resolution 1°C 1°F Accuracy ± 2% of reading or ± 2°C (whichever is greater) ± 2% of reading or ± 3°F (whichever is greater) Emissivity 0.95 Typical Response Time 1 second Optic Cœfficient 3:1 (ratio of distance to diameter of target) Battery Type 1 x 9V Dimensions 143 x 80 x 38 mm (5.6 x 3.2 x 1.5”) Weight 320 g (11.3 oz) HI 99550-00 & HI 99550-01 Infrared radiation emitted from an object depends on its temperature. The Hanna HI 99550 infrared thermometer employs this technology to measure the surface temperature. Infrared measurements are extremely practical with an instantaneous response time. Another main advantage is the non-intrusive nature of the measurements. This feature can translate itself into substantial savings in industries where products are sealed or pre-wrapped. In order to measure the temperature, simply point to the product or the spot and hold down the measurement key. The measured value will be immediately displayed on the LCD. This type of non-intrusive measurement is also useful when the surface temperature is high, for difficult-to-reach places or due to hygiene requirements. Hanna’s HI 99550 is designed with a wrist-strap and HOLD function for greater ease of use. The fast response time coupled with these features, makes the Hanna infrared meter particularly attractive for repetitive tests in the factory or on the production line. HI 99556-00 & HI 99556-01 HI 93640 2 in 1 infrared / penetration thermometer The new dual purpose HI 99556-00 is ideal for checking temperatures everywhere from the greenhouse to the field. Spot check with the infrared probe and get a closer look with the thermistor thermometer. Comes complete with probe and wrist strap. SPECIFICATIONS Range IR PROBE Resolution IR PROBE Accuracy IR PROBE Response Time Optic IR Cœfficient MIN Distance T° Probe Battery Dimensions Weight 31 HI 99556-00 HI 99556-01 -10 to 300°C 14 to 572°F -40 to 150°C -40 to 302°F 1°C 1°F 0.1°C 1°F ± 2% reading or ± 2°C ± 2% reading or 3°F ± 0.5°C (-20 to 120°C) ± 1°F (0 to 250°F) & ± 0.5°C+1% read. (out.) & ± 1°F+1% read. (out.) 1 second 3 : 1 (ratio of distance to diameter of target) 30 mm (1.2”) HI 765PW (optional) 1 x 9V 143 x 80 x 38 mm (5.6 x 3.1 x 1.5”) 320 g (11.3 oz) Compact, portable thermo-hygrometer HI 93640 is a compact, portable and versatile hygrometer with a convenient wrist-strap so that you can monitor relative humidity anywhere. The built-in thin-film capacitance sensor assures accurate humidity measurements from 5 to 95% RH with a resolution of 0.1%. The rubber keypad protects the keyboard from dust or accidental splashes. A sintered cap can be placed on the sensor shaft for protection in dusty environments. If fast response is desired, the cap can be removed. Designed to be operated with just one hand, the compact housing fits easily into your palm. This simple-to-use meter is ideal for the HVAC field. SPECIFICATIONS Range Resolution Accuracy Battery Type / Life Environment Dimensions Weight HI 93640 RH 5.0 to 95.0% °C 0.0 to 60.0 °F 32 to 140 RH 0.1% °C 0.1 °F 1 RH ± 2% °C ± 0.4 °F ± 1 for 1 year, excluding probe error 1 x 9 V / approximately 100 hours of continuous use 0 to 50°C (32 to 122°F); RH 98% non-condensing 190 x 80 x 38 mm (7.5 x 3.1 x 1.5”) 320 g (11.3 oz) 2004 Agricultural Catalog Thermometers & Hygrometers Professional meters SPECIFICATIONS MODELS WITHOUT HOOK MODEL RANGE HI 140A -30.0 to 70.0°C (-22.0 to 158.0°F) HI 140B -10.0 to 30.0°C (14 to 86°F) HI 140C -30.0 to 10.0°C (-22 to 50°F) HI 140D 20.0 to 60.0°C (68 to 140°F) HI 140E -30.0 to -10.0°C (-22 to 14°F) HI 140F 20.0 to 40.0°C (68 to 104°F) HI 140G -5.0 to 15.0°C (23 to 59°F) MODELS WITH HOOK (MOLDED EYE) MODEL RANGE HI 140AH -30.0 to 70.0°C (-22.0 to 158.0°F) HI 140BH -10.0 to 30.0°C (14 to 86°F) HI 140CH -30.0 to 10.0°C (-22 to 50°F) HI 140DH 20.0 to 60.0°C (68 to 140°F) HI 140EH HI 140FH HI 140GH • • • • • • -30.0 to -10.0°C (-22 to 14°F) 20.0 to 40.0°C (68 to 104°F) -5.0 to 15.0°C (23 to 59°F) HI 140 series ACCURACY ± 1.5°C/ ± 3°F ± 0.5°C/ ± 1°F ± 0.5°C/ ± 1°F ± 0.5°C/ ± 1°F ± 0.3°C/ ± 0.6°F ± 0.3°C/ ± 0.6°F ± 0.3°C/ ± 0.6°F HI 140 loggers weight only 150 grams each and are not much larger than your PC mouse. They are housed in a smooth, yet tough ABS casing that is sealed against ingress of dust and water. HI 140 models are tailor-made with different temperature ranges to make them more accurate for your specific needs. A green LED on the front of the meter will notify you of the logging status while a red LED serves as an alarm indication when undesired temperatures have been encountered. HI 140 series can monitor and store up to 7600 temperatures in nonvolatile memory for downloading and analysis. With our powerful software running under Windows®, you can select among others, your own high and low temperature alarm levels, Celsius or Fahrenheit recording, delayed start and monitoring interval. In addition, you can program each datalogger with a unique location number for easy identification. Downloading is performed through infrared lights without requiring cables and connectors–typical dirt-traps to be avoided at all costs in food applications. All loggers have the following features: programmable high and low alarm thresholds, programmable logging interval from 1 minute to 23 hours and 59 min., logging delay start selectable from 0 min. to 23 hours and 59 min., programmable serial and user ID numbers, infrared Bidirectional RS232 optical communication link, programmable real time clock and 3 x 1.5 AA batteries (included) with approx. life of 4 years at 25°C. ACCURACY ± 1.5°C/ ± 3°F ± 0.5°C/ ± 1°F ± 0.5°C/ ± 1°F ± 0.5°C/ ± 1°F ± 0.3°C/ ± 0.6°F ± 0.3°C/ ± 0.6°F ± 0.3°C/ ± 0.6°F 7600 recordings in nonvolatile EEPROM User-selectable interval from 1 minute to 24 hours Programmable serial and user ID numbers Out of range intermittent LED alarm signal AA batteries providing 4 years of continuous use Optional cordless transmitter MODEL and software programs for Windows® HI 141A (H) HI 141B (H) HI 141C (H) HI 141D (H) HI 141E (H) HI 141 series LCD • • HI 141F (H) HI 141G (H) • HI 141J (H) • SENSOR(S) 1 internal 1 external 1 internal 1 external 1 internal 1 external 2 external 1 internal 1 external 2 external RANGE -40.0 to 80.0°C (-40.0 to 175.0°F) -40.0 to 125.0°C (-40.0 to 257.0°F) -20.0 to 70.0°C (-4.0 to 158.0°F) -40.0 to 125.0°C (-40.0 to 257.0°F) -40.0 to 80.0°C (-40.0 to 175.0°F) -40.0 to 125.0°C (-40.0 to 257.0°F) -40.0 to 125.0°C (-40.0 to 257.0°F) -20.0 to 70.0°C (-4.0 to 158.0°F) -40.0 to 125.0°C (-40.0 to 257.0°F) -40.0 to 125.0°C (-40.0 to 257.0°F) SPECIFICATIONS FOR ALL MODELS • • • • • Countdown until the start of logging Number of samples taken Number of samples which have exceeded the HIGH/LOW alarms HIGH and LOW temperature values HIGH and LOW alarm settings Resolution Accuracy Diameter Height Weight 0.1°C (-40.0 to 100.0°C); 0.2°C (temp.>100.0°C) / 0.1°F (-40.0 to 190.0°F); 0.3°F (T°. >190.0°F) ± 0.5°C (-40.0 to 0.0 and 70.0 to 100.0°C); ± 0.4°C (0.0 to 70.0°C); ± 1.0°C (T° >100.0°C) ± 1.0°F (-40.0 to 32.0 and 158.0 to 212.0°F); ± 0.8°F (32.0 to 158.0°F); ± 2.0°F (T° > 212.0°F) 86.5 mm (3.4”) 35 mm (1.4”) 150 g (5.54 oz) The HI 141 series is a family of temperature data loggers with either one or two channels, internal or external temperature sensors, and an optional LCD. External temperature sensor models feature one or two stainless steel sensors on a 1 meter (3.3') cable for direct insertion. HI 141 can store up to 16,000 temperature samples in a protected, non-volatile EEPROM memory. The logging interval can be set from once per second up to every 24 hours and logging delay start can be set anywhere up to 199 hours. The MIN or MAX temperature between logging intervals can also be stored. All of your collected data is tamper-proof and stored into serial numbered lots. The user interacts with the logger; setting data acquisition parameters or downloading logged data, through an RS232 serial port on a Windows® PC. The HI 141000 Windows® software supports communication between the logger and the PC through the HI 141001 infrared transmitter. The housing is waterproof to IP 67 standards and can include a convenient hanging loop (simply add an "H" to the end of the code). A long-life AA lithium battery provides power. For a typical 1 minute logging interval, your battery will last about 4 years. Hanna's unique Battery Error Protection System (BEPS) signals when it is time to change the battery and the housing is designed so you can change the battery yourself. The HI 141 series feature a LCD that show immediately the current temperature, channel and status of the logging sequence according to your programmed instructions 2004 Agricultural Catalog 32 Thermometers & Hygrometers Turf Temp New Turf-Temp 4000 - TT4000 • • 1, 4, 8 channel data recorder Logging capacity for temperatures under turf covers and other external applications Come with standard • HI 766F K-type thermocoupe probe • 30’ of 2 wire conductor cable • Stainless mounting stand • NEMA 4X enclosure CSA humidity and dust proof TURF-TEMP 4000 (TT4000) The TT4000 takes the guess work out of temperature monitoring of important turf and other environmental areas in colder climates. The TT4000 is a miniature, battery powered, stand alone, thermocouple based recorder, housed in a Nema 4 rated enclosure, mounted on a stainless steel pedestal. The unit comes standard with 30 feet of 2 wire conductor cable, a stainless steel K type probe, and the software to display the log activity (either chart or graph) of both the probe temperatures and ambient temperatures. This gives the user all information for environmental studies, turf protection decisions, and other related actions. Logging intervals can be programmed from one reading every 2 seconds to one reading every 12 hours, based on your needs. These units come in 4 different models, to measure up to 4 separate areas of a green, sports field, or other area. In addition, longer 2 wire cables can be ordered for applications where necessary. The storage medium is nonvolatile solid state memory, providing maximum data security even if the battery becomes discharged. HI 766F - High temperature probe SPECIFICATIONS Internal Channel Temperature Range Temperature Resolution Start Time -40 to 80°C 0.1°C Software programmable start time. Up to six months in advance Real Time Recording May be used with PC to monitor and record data in real time Reading Interval 1 reading every 2 seconds to one reading every 12 hours Memory 16 383 readings per channel Operating Environment -40 to 80°C, 5 to 95% RH non-condensing INFO Turf temperature can change dramatically during the winter and spring seasons. Knowing what is happening under the protective covers is critical for turf managers. The new turf temp from Hanna Instruments will log and record historical and real time data of temperature activity both; under the protective covers, and the ambient temperatures around the recorders. This gives the turf manager another important tool in the job to maintain perfect playing surfaces. • • • • • 33 TURF TEMP Flexible sheath MAX temperature: 1100°C / 2000°F Response time (90% of final value): 4 sec. Probe length: 255 mm (10”); dia 1.5 mm (0.6”) Tube in AISI 316 stainless steel (no-handle) 2004 Agricultural Catalog Thermometers & Hygrometers Professional meters SPECIFICATIONS Range Resolution Accuracy Typical EMC Deviation Probe Battery Type / Life Environment Dimensions Weight (meter only) RH °C RH °C RH °C RH °C HI 8564 10.0 to 95.0% 0.0 to 60.0°C (32 to 140°F) 0.1% 0.1°C (1°F) ± 2% ± 0.4°C (± 1°F for 1 year, excluding probe error) ± 2% ± 0.5°C (± 1°F) HI 70601/2 TFPC RH and T° probe with 2 m (6.6’) cable 1 x 9V / approximately 100 hours of continuous use 0 to 50°C (32 to 122°F); RH 98% non-condensing 185 x 82 x 45 mm (7.3 x 3.2 x 1.8”) 315 g (11.1 oz) HI 8564 • • • Flexible long cable Quick response time 2 meters in 1 Portable thermo-hygrometer with detachable probe HI 8564 thermo-hygrometer provides readings with 98% precision in a very short time for both R.H. and temperature. The detachable R.H. probe is housed in a rugged ABS cylinder with a thin-film polymer humidity sensor and a signal amplifier. A perforated cap on the probe allows the air to circulate while it protects the sensitive sensor. The standard cable is 2 m long (7'), and a 5 meter (16.5') version is also available. Specially designed for internal applications such as museums, libraries, computer rooms and printing facilities. The smooth membrane keyboard has 4 keys that make operation simple and quick. A large LCD displays readings in easy-to-read digits each with a symbol next to it to identify the operating mode. HI 9065 SPECIFICATIONS Range Resolution Accuracy Typical EMC Deviation Calibration RH Probe Battery Type / Life Environment Dimensions (meter only) Weight (meter only) RH °C RH °C RH °C RH °C °F HI 9065 5.0 to 95.0% 0.0 to 60.0°C (32 to 140°F) 0.1% 0.1°C (1°F) ± 2% ± 0.4°C (± 1°F for one year, excluding probe error) ± 3% ±2 ±4 Through 2 trimmers on RH probe HI 70605/2 RH with 2 m (7’) cable (included) 4 x 1.5V AA / approx. 500 hours of continuous use 0 to 50°C (32 to 122°F); RH 100% 196 x 80 x 60 mm (7.7 x 3.1 x 2.4”) 425 g (15 oz) Professional yet simple water-resistant hygrometer HI 9065 is a heavy-duty hygrometer specially designed for field applications such as HVAC. It is housed in a rugged water-resistant case to provide maximum protection for the electronics in the field. The Relative Humidity probe houses a thin-film polymer sensor which performs all RH readings to 98% accuracy very quickly. A "HOLD" key will instantly freeze the reading on the LCD. HI 9065 can also measure temperature with internal sensor of the RH probe from 0 to 60 in the Celsius as well as 32 to 140 in the Fahrenheit scales. 2004 Agricultural Catalog 34 Control Systems pH & nutrients control Hydrobox Automatic pH & fertilizer control system for indoor gardening (hydroponics) Simple to operate, easy to install, reliability and affordability are just some of the features that make the Hydrobox series a winning product. Now everyone can have 24 hours a day / 7 days a week control over their reservoir, with overdose protection. Free up your time for other activities, and have happy, healthy plants! • • • • • • Automatic control 24 hours per day / 7 days a week Protection against pH or nutrient overdosing (added security) Adjustable setpoints Easy installation, no hardwire necessary Affordable Compact size 6'' x 6'' x 6'' Hydrobox pH pH controller with visual alarm, built-in overdose timer protection. Hydrobox Deluxe Automatic pH and nutrient control (EC or TDS) with visual alarm and overdose timer protection. Hydrobox EC/TDS Nutrient controller with visual alarm and overdose timer protection. Many models available: HB/EC HB/TDS HB/pH-1001 HB/pH-1006 HB/pH-1286 HBDEL/EC1001 HBDEL/EC1286 HBDEL/TDS1286 Growpal-A & Growpal-F Grower’s Pal pH & fertilizer control system for reservoirs. Versatile. Greenhouse recommanded. • • • • • Easy to set up and install Easy to use and program Manual calibration & accurate digital readout Handy individual calibration solution packets Auto/off/prime switches for pump control. No more manual priming • • • • Overdose timing protection for fertilizers & acid Audible, visual & auxiliary alarms “No flow” detection for recirculation circuit Waterproof, dustproof & rustproof. 2 year warranty Grower’s Pal typical installation F.S. HI 2222 Sampling circuit 110VAC EC probe pH probe Auxiliary alarm output 110VAC Recirculating pump Dosing Pumps HI 3333 Diffuser to plants Watering pump Acid 35 A B Water Input 2004 Agricultural Catalog Control Systems Irrigation / fertilization controllers HI 8001 - F1 Controller Panel mount irigation/fertilization controller The HI 8001 F1 Controller is a practical solution to automated irrigation and fertilization control for up to 32 sectors. Ideal for large fields, greenhouses, hydroponic and soil farms, orchards, public gardens and golf courses. The F1 Controller is also capable of mixing, agitation and level control, filter flushing and water pump activation. Control is performed precisely and automatically, from any distance (requires HI 98143-22), by using both analog and digital signal inputs and outputs, as well as an RS 232 output for a PC or network interface with custom software. • HI 8001-01 HI 8001-02 HI 8001-03 HI 8001-04 Fertilization/irrigation controller for 8 sectors Fertilization/irrigation controller for 16 sectors Fertilization/irrigation controller for 24 sectors Fertilization/irrigation controller for 32 sectors • • • • • • 16 digital inputs for temporary break, conditional stop, irrigation count, differential pressures and fertilizer, acid, mixing and external tank level controls. 6 analog inputs for pH sensors, EC sensors and solar radiation sensors. 2 non-consent alarm relays. 7 digital outputs for filter back flushing, pH and fertilizer tanks. Inputs 24 VAC output power supply and 110/220 VAC with grounding (internal power). PID Control reduces overdosing and large oscillations in the mixing process. Logging of executed programs with values of all parameters. Information Center - Splash-proof polyester membrane cover consisting of: • 4-level LCD used for programming and data presentation. • 32 Light Emitting Diodes (LED's) for each sector valve. • 9 LED's for each of the fertilizer tanks, pH control, mixer and filters. • 2 extra-large LED’s for the alarm and pump functions. HI 8002 Waterproof wall mount irrigation/fertilization controller. The HI 8002 includes all the features of the HI 8001 but in a waterproof, NEMA 4X enclosure. HI 8002-01 HI 8002-02 HI 8002-03 HI 8002-04 2004 Agricultural Catalog NEMA 4, waterproof fertilization/irrigation controller for 8 sectors NEMA 4, waterproof fertilization/irrigation controller for 16 sectors NEMA 4, waterproof fertilization/irrigation controller for 24 sectors NEMA 4, waterproof fertilization/irrigation controller for 32 sectors 36 Control Systems Irrigation / fertilization controllers SPECIFICATIONS Range pH EC Solar Radiation Resolution Accuracy (@20°C/68°F) pH EC Solar Radiation Typical Inputs Typical Outputs Number of Programs Priority for Programs Program Method Irrigation Capacity Irrigation Control Readout Power Supply Environment Dimensions Weight Required accessories HI 8001 & HI 8002 F1 CONTROLLERS 0.0 to 14.0 0.0 to 20.0 mS/cm 0 to 2000 W/m2 0.1 pH / 0.1 mS/cm / 1 W/m2 ± 0.0546 ± 0.078 mS/cm ± 0.78 W/m2 2 pH electrodes, 3 conductivity probes, solar radiation monitor, 4 fertilizer tanks, 1 acid tank, 5 tank level controls, 1 mixing tank level control, 2 differential pressures, 1 irrigation counter, 1 temporary break, 1 conditional stoppage 2 non-consent alarms, up to 32 sector valves, 2 filter flushing, pump, agitator, 4 fertilizer tank electro-valves, 1 pH tank electro-valve 10 5 levels (1 through 5) With keypad or through a PC using proprietary software 8, 16, 24 and 32 sector valves Time/volume control, 1 to 6 different timetables per program, accumulated solar radiation, low tank levels, manually 20-digit, 4 level LCD with graphic symbols and messages 115/220 V; 50/60 Hz HI 8001: 0 to 50°C (32 to 122°F); max 85% RH non-condensing; HI 8002: NEMA 4X specifications 178 x 260 x 115 mm (7.1 x 10.4 x 4.6") HI 8001: 3.4 Kg (7.5 lb.); HI 8002: 280 x 330 x 165 mm (11.2 x 13.2 x 6.6”) HI 98143-22 pH/EC isolated transmitter, non-sourcing current type with 4-20 mA output (2 required) F1 typical installation 37 2004 Agricultural Catalog Control Systems Transmitter & level controller HI 8666 RH/°C transmitter panel mounted The highly accurate humidity and temperature transmitter can be mounted anywhere in the greenhouse to relay temperature and humidity values via an analog signal to remote panel meters or controllers. • • • SPECIFICATIONS Range RH °C Resolution RH °C Accuracy RH °C Response Time Power Supply (Required) Dimensions Weight Sintered metal cap 4-20 mA output Dual-range transmitter HI 8666 0% (4mA) to 100% (20 mA) -20 (4mA) to 60 (20 mA) ± 0.125%, ± 0.02 mA ± 0.1, ± 0.02 mA ± 2% (5% to 80% RH); ± 4% (80% to 90% RH) ± 1% of span 6 seconds without sintered filter, 60 seconds with filter 12 to 24 VDC for each signal (external not included) needed at undecal connector (not included) i.e. the voltage entry point to HI 8666 79 x 49 x 140 mm (3.1 x 1.9 x 5.5”) 200 g (7 oz) HI 7873 Level controller HI 7873 is ideal for nutrient and acid tank level control over distances of up to 1,000’. This compact controller will prevent one or more of the nutrient tanks from running dry, assuring that the nutrient mix is always correct. • • • • High, low and over Level indication Output contact Compact design SPECIFICATIONS Transmission Connection Level Adjustment Level Indication Sensor Bars Transmitter Output Contact Power Supply Dimensions Weight 2004 Agricultural Catalog HI 7873 300 meters (990’) max. HI 7164 (11 pin connector) High, low, and overflow High, low, and overflow 4 pieces (min); HI 731324 pack of 5 pcs (not included) HI 7874 (not included) 2 relays of 2 A/max. 240 V resistive load 1 000 000 strokes 110/15V; 50/60 Hz 79 x 49 x 95 mm (3.1 x 1.9 x 3.8”) 150 g (5.3 oz) 38 Control Systems Chemical metering pumps These simple and reliable diaphragm pumps are composed of high quality components and incorporate chemical-resistant Teflon® and Kynar® heads and diaphragms. The Blackstone series of pumps are positive displacement solenoid driven, using a minimum number of moving parts, therefore reducing the chance of mechanical failure. Blackstone pumps Many models available: A wide range of Blackstone pumps with different dosing capacities are available for your specific dosing needs. Each pump is supplied with the installation kit including polyethylene tubing, ceramic weights, injection valve and suction valve. Valve/Hose Assembly Diagram NECK Hanna Instruments Blackstone Series BL1.5/D BL1.5/U BL3/D BL3/U BL5/D BL5/U BL7/D BL7/U BL10/D BL10/U BL15/D BL15/U BL20/D BL20/U 220/240V, 1.5 lph (0.4 gph) 110/115V, 1.5 lph (0.4 gph) 220/240V, 2.9 lph (0.8 gph) 110/115V, 2.9 lph (0.8 gph) 220/240V, 5.0 lph (1.3 gph) 110/115V, 5.0 lph (1.3 gph) 220/240V, 7.6 lph (2.0 gph) 110/115V, 7.6 lph (2.0 gph) 220/240V, 10.8 lph (2.9 gph) 110/115V, 10.8 lph (2.9 gph) 220/240V, 15.2 lph (4.0 gph) 110/115V, 15.2 lph (4.0 gph) 220/240V, 18.3 lph (4.8 gph) 110/115V, 18.3 lph (4.8 gph) Design Reliable High quality material Ideal for dosing nutrients & acids Part# With Large Diaphragms BL 20 BL 15 BL 10 BL 7 Output LPH 18.3 15.2 10.8 7.6 With Small Diaphragms BL 5 BL 3 BL 1.5 5.0 2.9 1.5 SPECIFICATIONS Maximum Capacity Pump Casing Pumphead Fittings Self-Priming Power Supply Max. Absorbed Power Dimensions Weight 39 • • • • Rated Pressure GPH BAR 4.8 0.5 4.0 1 2.9 3 2.0 3 1.3 0.8 0.4 7 8 13 PSI 7.3 14.5 43.5 43.5 Strokes/min 120 120 120 120 101.5 116 188.5 120 120 120 BL.../U BL.../D See chart above Fiber-reinforced polypropylene Pumphead in Kynar®, diaphragm and valve seats in Teflon®, glass ball valves and O-Rings in Viton® Polyethylene 5 x 8 mm tubing Max. self-priming height 5 feet (1.5 m) 110/115 V, 50/60 Hz 220/240 V, 50/60 Hz Approximately 200 W 165 x 194 x 121 mm (6.5 x 7.6 x 4.8”) 6.6 lb. (3 kg) 2004 Agricultural Catalog Personalyzed Kits & Accessories MAL 100 HI 740218 Need an extra in it? Need to fit more than one meter? Ask for your personalized kit and experience the Hanna difference! All colorimeters can be custom fit into a rugged carrying case for ease of use and transportation. Pre-cut foam pieces allow the user to easily fit reagents, cuvets, caps, wiping tissue, etc. Ask us to do it for you, we'll be glad to get it ready to use when it gets to your door! Accessories HI 710007 HI 710008 HI 710009 HI 710010 Blue rubber boot for HI 991001-2-3, HI 991300-01 Orange rubber boot for HI 991001-2-3, HI 991300-01 Blue rubber boot for colorimeters & HI 9810-11-12 Orange rubber boot for colorimeters & HI 9810-11-12 HI 92000 HI 9200 HI 920010/9 Windows® compatible software for portables meters 9-pin infrared transmitter 9 to 9-pin connection cable for HI 98140 - HI 98150 HI 710001 Soft carrying case for colorimeters HI 731321 HI 731325 HI 731318 Cuvets (4 pcs) for Colorimeters Caps (4 pcs) for Colorimeters Tissue (4 pcs) for wiping cuvets HI 76302W/10 HI 76302W/20 HI 76302W/30 10 m. EC probe for HI 9033-34 & HI 933300-01 20 m. EC probe for HI 9033-34 & HI 933300-01 30 m. EC probe for HI 9033-34 & HI 933300-01 HI 76407/10 HI 76407/20 HI 76407/30 10 m. D.O. probe for HI 9143-45 & HI 9141-410 20 m. D.O. probe for HI 9143-45 & HI 9141-410 30 m. D.O. probe for HI 9143-45 & HI 9141-410 2004 Agricultural Catalog HI 710034 HI 710035 10 paper rolls for portable meters Ink cartridge for portable meters HI 93701-00 HI 93701-10 HI 93701-11 HI 93701-25 HI 93701-50 Free Chlorine standard 0 mg/l, 4 pcs Free Chlorine standard 1 mg/l, 4 pcs Free Chlorine standards 0, 0.25, 0.5 and 1 mg/l, 1 of each (4 pcs) Free Chlorine standard 0.25 mg/l, 4 pcs Free Chlorine standard 0.5 mg/l, 4 pcs HI 93703-0 HI 93703-10 HI 93703-05 AMCO-EPA cal. solution, 0 NTU, 30 ml for HI 93703 AMCO-EPA cal. solution, 10 NTU, 30 ml for HI 93703 AMCO-EPA cal. solution, 500 FTU, 30 ml for HI 93703-11 HI 76407A/P Pack of 5 replacement membranes for HI 9143-45 & HI 9141-410 Dissolved Oxygen meters Electrolyte solution for Dissolved Oxygen meters, 30 ml HI 7041S HI 740218 HI 721317 HI 93703-C MAL-100 Carrying case for colorimeters and turbidity meters General carrying case for waterproof & printing/logging meters HI 93703 complete kit with case and accessories Personalized carrying case 40 Calibration & Maintenance Solutions It is difficult to exaggerate the importance of buffer and maintenance solutions. Expensive equipment is often utilized well below its full capabilities due to lack of proper maintenance of sensors. With Hanna solutions, this is no longer a problem. 4 liter size Maintenance kit 1 liter size 460 ml size 230 ml size 20 ml size EC TDS pH Calibration starter kits 41 CODE HI 7007/1G HI 7007/1L HI 7007L HI 7007M HI 70007P DESCRIPTION pH 7.01 calibration buffer, colored pH 7.01 calibration buffer, colored pH 7.01 calibration buffer pH 7.01 calibration buffer pH 7.01 calibration buffer SIZE 4 liter 1 liter 460 ml 230 ml 25 x 20 ml HI 7004/1G HI 7004/1L HI 7004L HI 7004M HI 70004P pH 4.01 calibration buffer, colored pH 4.01 calibration buffer, colored pH 4.01 calibration buffer pH 4.01 calibration buffer pH 4.01 calibration buffer 4 liter 1 liter 460 ml 230 ml 25 x 20 ml HI PHKIT pH calibration starter kit 3 x 20 ml (pH 7) + 3 x 20 ml (pH 4) HI 7061L HI 7061M Cleaning solution for pH testers/meters Cleaning solution for pH testers/meters 460 ml 230 ml HI 70300L HI 70300M Storage solution for pH testers/meters Storage solution for pH testers/meters 460 ml 230 ml HI MTNKIT Maintenance kit (cleaning & storage) 1 x 230 ml (cleaning) + 1 x 230 ml (storage) CODE HI 7032L HI 7032M HI 70032P DESCRIPTION 1382 ppm calibration solution, 0.5 conv. factor 1382 ppm calibration solution, 0.5 conv. factor 1382 ppm calibration solution, 0.5 conv. factor SIZE 460 ml 230 ml 25 x 20 ml HI 70442L HI 70442M HI 70442P 1500 ppm calibration solution, 0.65 conv. factor 1500 ppm calibration solution, 0.65 conv. factor 1500 ppm calibration solution, 0.65 conv. factor 460 ml 230 ml 25 x 20 ml HI TDSKIT 1382 ppm calibration starter kit 5 x 20 ml CODE HI 7030L HI 7030M HI 70030P DESCRIPTION 12880 µS/cm calibration solution 12880 µS/cm calibration solution 12880 µS/cm calibration solution SIZE 460 ml 230 ml 25 x 20 ml HI 7031L HI 7031M HI 70031P 1413 µS/cm calibration solution 1413 µS/cm calibration solution 1413µS/cm calibration solution 460 ml 230 ml 25 x 20 ml HI ECHKIT HI ECLKIT 12880 µS/cm calibration starter kit 1413 µS/cm calibration starter kit 5 x 20 ml 5 x 20 ml 2004 Agricultural Catalog Warranty Policy Hanna Instruments products are manufactured in our ISO 9001 facilities meeting the highest quality standards in the industry. Hanna's high standards also apply should a product be returned due to defects in material or workmanship. Our extensive warranty extends up to 3 years on some products. Limitations : Warranty products may be returned for repair or replacement only, at the discretion of Hanna Instruments. In some circumstances, remedy may constitute refund for the price paid for the product. The warranty period commences from the original date of sale to the end-user buyer. Warranty is valid only when the product is used under normal conditions and in accordance with operating limitations and prescribed maintenance procedures. The express warranty stated previously is the only express warranty given by Hanna to the end-user buyer. Hanna expressly disclaims any warranties implied by law, including but not limited to warranty of merchantability of fitness for a particular purpose. Hanna shall not be liable for any kind of breach of any warranty, negligence, on the basis of strict liability or otherwise. 2004 Agricultural Catalog HANNA Instruments agriculture warranty periods are : 3 Years 2 Years 2 Years 2 Years 2 Years 1 Year 1 Year 1 Year 1 Year 6 Months 3 Months pH 300 bench top meters Portable meters Bench meters Printing meters Stirrers & industrial meters Dosing pumps Waterproof testers Testers & pocket size Tthermometers Electrodes & probes Replacement pH probe HI 73127 pH Checkpak® 42