SIMATIC WinCC V12 Engineering for all HMI-Systems

Transcription

SIMATIC WinCC V12 Engineering for all HMI-Systems
SIMATIC WinCC V12
Engineering for all HMI-Systems
Release
Management
Communication
Maintenance
Tag management
Engineering
Edition
Hardware
WinCC Professional 512, 4k, max. PowerTags
WinCC Advanced
WinCC Comfort
WinCC Basic
Screens
SCADA
Basic Panels
PLC & HMI
Comfort Panels,
Mobile Panels
Panel PC,
Standard PC
SCADA
Overview
Panel
Usability
Single Station
… based on WinCC flexible RT
Page 1
2012-10-29
SCADA System
… based on WinCC V7 Runtime
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
Maintenance
Tag management
Screens
SCADA
SIMATIC HMI Basic Panels
KP300 Basic
KP400 Basic
New
KTP 400 Basic,
KTP 600 Basic,
KTP 1000 Basic, TP 1500 Basic
SIMATIC HMI Panels / Multi Panels
OP73, OP77, TP177, OP177,
TP277, OP277,
MP177, MP277, MP377
SIMATIC HMI Mobile Panels
PLC & HMI
Mobile Panel 177, Mobile Panel 277
Mobile Panel 277 IWLAN V2
Usability
SIMATIC HMI Comfort Panels
Overview
Page 2
WinCC Basic
Communication
WinCC Comfort
Release
Management
WinCC Advanced
Hardware
WinCC Professional
SIMATIC WinCC V12
Supported hardware
KTP 400 Comfort, KP 400 Comfort,
TP 700 Comfort, KP 700 Comfort,
TP 900 Comfort, KP 900 Comfort
TP 1200 Comfort, KP1200 Comfort
TP 1500 Comfort, KP1500 Comfort
TP 1900 Comfort, TP2200 Comfort
2012-10-29
Visualization with WinCC V12
New
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
1
Release
Management
Communication
Maintenance
Tag management
Screens
WinCC Advanced
Hardware
WinCC Professional
SIMATIC WinCC V12
Supported hardware
SCADA
PLC & HMI
SIMATIC WinCC Runtime Advanced (PC-based single station)
…with 128, 512, 2k, 4k PowerTags
IPC227D, IPC277D
IPC427C/D, IPC477C/D
IPC577C
IPC627C, IPC827C
IPC677C
IPC647C, IPC847C
IPC547D
Standard PC
SIMATIC WinCC Runtime Professional (PC-based SCADA)
Usability
…with 128, 512, 2k, 4k, 8k, 64k PowerTags
Overview
IPC427C/D, IPC477C/D (Client)
IPC577C (Client)
IPC627C, IPC827C
IPC677C
IPC647C, IPC847C
IPC547C/D
Standard PC
Page 3
2012-10-29
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
SIMATIC WinCC V12
Comfort Panels – Overview
Hardware
Release
Management
Communication
Maintenance
Display size
4''W
7''W
4,3''
7,0''
Resolution
480x272
Prozessor
New
New
New
19''W
22''W
9''W
12''W
15''W
9,0''
12,1''
15,4''
800x480
1280x800
18,5''
21,5''
1366x768
1920x1080
ARM 532 MHz
x86 500 MHz
x86 1GHz
Project memory
4 MB
12 MB
24 MB
Screens
Tags
1024
2048
4096
SCADA
Messages
2000
4000
6000
PLC & HMI
Recipes
100 / 200 / 200 *
300/ 500 / 1000 *
500 / 1000 / 2000
500
500
Tag management
Usability
Overview
Images
Archives
Scripts
750
10 / 10.000 **
50
Viewer / multimedia
50 / 50.000 **
100
200
Internet Explorer, PDF, Word- and Excelviewer, Multimedia Player
Sm@rtServer
yes
*) recipes / data sets per recipe / entries per data set
Page 4
2012-10-29
Visualization with WinCC V12
**) Archive / entries per archive
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
2
SIMATIC WinCC V12
Industrial Thin Client – SIMATIC ITC
New
SIMATIC ITC
Resolution
ITC1200
ITC1500
12" Touch
Widescreen
15" Touch
Widescreen
1280 x 800
ITC1900
1280 x 800
Display
22" Touch
Widescreen
1366x768
1920 x 1080
high resolution, 16 Mio. colors, 100% dimmable
CPU
Intel Celeron 1,2 GHz
Interfaces
1 x GBit LAN , 2 x USB 2.0 (backside)
Webbrowser
HTML5, XML, CSS, JavaScript
Protocols
Sm@rtServer, RDP, VNC
Active connections
5
Power supply
24V DC
Certificates
CE, cULus, C-Tick, ATEX Zone 2/22 (planned)
Produkt link: 60521782
Page 5
ITC2200
19” Touch
Widescreen
2012-10-29
FAQ: 63258317
Produktvideo
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
SIMATIC WinCC V12
1 – Compatibility mode
Hardware
Release
Management
TIA Portal V12 support for the Service use case
 Exception: Compile of Runtime Professional V11
Communication
Maintenance
WinCC ES V11 SP2
Tag management
WinCC ES V12
(compatibility mode)
V11
Proj.
RT V11
SP2
Screens
RT V11
SP2
V12
Upgrade Proj.
WinCC ES V12
RT V11
SP2
RT
V12
SCADA
PLC & HMI
RT V11
SP2
Usability
RT
V12
Overview
Panel / SCADA 1
Page 6
2012-10-29
Visualization with WinCC V12
Panel / SCADA 2
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
3
SIMATIC WinCC V12
1 – Compatibility mode
Work on V11 projects with V12
 V11 project can be modified with different versions of the engineering system
 Saved projects can be opened with TIA Portal V11 SP2 again
WinCC V11
SP2
V11
Proj.
Page 7
Engineering
system
Engineering
system
 Functionality and features of TIA Portal V11 SP2 products are supported
2012-10-29
WinCC V12
(V11 compatibility mode)
*Compile and download not supported
for Runtime Professional V11
Open project supported
Edit/compile/download
devices supported*
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
SIMATIC WinCC V12
2 – Upgrade to V12
Hardware
Release
Management
Use of new functionality coming with WinCC V12
 Exception: Compile As Runtime Professional V11
Communication
WinCC ES V11 SP2
Maintenance
Tag management
WinCC ES V12
(compatibility mode)
V11
Proj.
RT V11
SP2
Screens
RT V11
SP2
V12
Upgrade Proj.
WinCC ES V12
RT V11
SP2
RT
V12
SCADA
PLC & HMI
RT V11
SP2
Usability
RT
V12
Overview
Panel / SCADA 1
Page 8
2012-10-29
Visualization with WinCC V12
Panel / SCADA 2
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
4
SIMATIC WinCC V12
2 - Upgrade to V12
Hardware
Use of new functionality coming with WinCC V12
Release
Management
 Use of new functions (e.g. S7-1500)  V11 project must be upgraded to V12
Communication
 Panels and RT Advanced remain in version 11 for service use cases
 Project upgrade includes upgrade of RT Professional
Maintenance
Engineering
system
Tag management
Screens
SCADA
PLC & HMI
Upgraded V11 project or newly
created V12 project can only be
opened with TIA Portal V12
products
WinCC V12
Usability
Overview
Save (V12) project supported
V11
Proj.
Page 9
2012-10-29
V12
Proj.
Edit/compile/download
devices supported
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
SIMATIC WinCC V12
2 – How to…
Hardware
Release
Management
Communication
Maintenance
Upgrade V11 projects to V12
 V11 project file remains available
 V12 project build in a new folder named “..._V12”
 No downgrade afterwards, no more use in TIA Portal V11
Tag management
Screens
SCADA
3
2
PLC & HMI
1
Upgrade to V12
Usability
Overview
Page 10
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
5
SIMATIC WinCC V12
3 – V11 devices in TIA Portal V12
Hardware
Release
Management
Create, modify and compile V11 devices in V12 project
 Exception: Compile As Runtime Professional V11
Communication
Maintenance
WinCC ES V12
(compatibility mode)
V11
Proj.
WinCC ES V11 SP2
Tag management
RT V11
SP2
Screens
V12
Upgrade Proj.
RT V11
SP2
WinCC ES V12
RT V11
SP2
RT
V12
SCADA
PLC & HMI
RT
V11
Usability
RT
V12
Overview
Panel / SCADA 1
Page 11
2012-10-29
Panel / SCADA 2
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
SIMATIC WinCC V12
3 – V11 devices in TIA Portal V12
Hardware
No upgrade of Panels FW forced by new version of engineering system
Release
Management
 WinCC V12 can configure devices with RT versions V11 and V12
Communication
 Version change (V11↔V12) is handled similar to Device type change
 Configured RT version decides about supported functionality in editors
Maintenance
Engineering
system
Tag management
Screens
SCADA
PLC & HMI
WinCC V12
Compile and download not supported
for Runtime Professional V11
Usability
Overview
V11 device
V12
Proj.
Page 12
2012-10-29
V12 device
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
6
SIMATIC WinCC V12
Upgrade process
Hardware
Release
Management
Communication
Maintenance
Upgrade V11 projects to V12
 V11 project file remains available
 V12 project build in a new folder named “..._V12”
 No downgrade afterwards, no more use in TIA Portal V11
Tag management
Screens
SCADA
3
2
PLC & HMI
1
Upgrade to V12
Usability
Overview
Page 13
2012-10-29
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
SIMATIC WinCC V12
V11 devices in TIA Portal V12
Hardware
No upgrade of Panels FW forced by new version of engineering system
Release
Management
 WinCC V12 can configure devices with RT versions V11 and V12
Communication
 Version change (V11↔V12) is handled similar to Device type change
 Configured RT version decides about supported functionality in editors
Maintenance
Engineering
system
Tag management
Screens
SCADA
PLC & HMI
WinCC V12
Compile and download not supported
for Runtime Professional V11
Usability
Overview
V11 device
V12
Proj.
Page 14
2012-10-29
V12 device
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
7
SIMATIC WinCC V12
Select RT version
Configurable RT
version in “Add new
device” dialog
Configurable
RT version in
Hardware catalog
Page 15
2012-10-29
Visualization with WinCC V12
Configured RT version
in Catalog information
of configured device
(EditorFor
Devices
networks)
internal&use
only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Change RT version
Change device type /
version for selected
device
Page 16
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
8
SIMATIC WinCC V12
Communication drivers
Hardware
Release
Management
Communication
Maintenance
WinCC Basic offers drivers for:
SIMATIC S7-1500
New
SIMATIC S7-1200
SIMATIC S7-300/400
Tag management
SIMATIC S7-200
Screens
LOGO!
SCADA
Allen-Bradley DF1, EtherNet/IP
PLC & HMI
Mitsubishi MC TCP/IP
Usability
Modicon Modbus TCP/IP
New
Overview
No support for SIMATIC S5
Page 17
2012-10-29
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
SIMATIC WinCC V12
Communication drivers
Hardware
Release
Management
Communication
Maintenance
WinCC Comfort / Advanced offers drivers for:
SIMATIC S7-1500
New
SIMATIC S7-1200
SIMATIC S7-300/400
Tag management
SIMATIC S7-200
Screens
LOGO!
SCADA
Allen-Bradley DF1, EtherNet/IP
PLC & HMI
Mitsubishi FX, MC TCP/IP
Usability
Modicon Modbus RTU, TCP/IP
Overview
New
Omron Host Link
Communication driver
OPC (DA, XML DA, UA)
No support for SIMATIC S5
Page 18
2012-10-29
Visualization with WinCC V12
* SINUMERIK Integrate Create MyHMI / WinCC
option has to be installed
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
9
SIMATIC WinCC V12 Process Communication Driver
What’s new: LOGO!
Hardware
Release
Management
Communication
Maintenance
Communication driver for LOGO!
Communication interface
 Ethernet
Available in HMI devices
Tag management
 Basic PN Panels
Screens
 Mobile Panels 177PN, 277
SCADA
 Multi Panels
PLC & HMI
 Comfort Panels
Usability
 Runtime Advanced
Overview
Data Type and address range
Page 19
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Communication drivers
Hardware
Release
Management
Communication
Maintenance
WinCC Professional offers drivers for:
SIMATIC S7-1500
New
SIMATIC S7-1200
SIMATIC S7-300/400
Tag management
Allen-Bradley EtherNet/IP
Screens
Mitsubishi MC TCP/IP
SCADA
Modicon Modbus TCP/IP
PLC & HMI
OPC (DA / XML DA)
Usability
Overview
No support for SIMATIC S5
Communication driver
Page 20
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
10
SIMATIC WinCC V12
Diagnostic services
Hardware
STEP 7
Release
Management
HMI
WebServer
CPU-Display
Communication
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 21
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Diagnostic services – Display at Panels / RT Advanced
Hardware
Release
Management
Communication
System diagnostics viewer
 Displays the overview of accessible devices and the system state of the plant
 Switch between device and detail view
Maintenance
 Same concept at Comfort Panels, RT Advanced, CPU display and CPU webserver
Tag management
 There is also a buffer viewer available for Basic Panels
Screens
SCADA
PLC & HMI
Usability
Overview
Page 22
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
11
SIMATIC WinCC V12
Diagnostic services – Display at Panels / RT Advanced
Hardware
Release
Management
Communication
System diagnostics viewer – detect errors in plant
 Click forward through structure to find out the source of an error
 Autofocus on faulty device
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 23
2012-10-29
SIMATIC WinCC V12
New service concept
Hardware
Release
Management
Communication
Maintenance
Tag management
Screens
SCADA
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Basic Panels
New panel service concept - Basic Panels
New
 Runtime project stored on S7-1500
 In the case of a device replacement the
HMI backup can be uploaded
from the PLC directly into the new
panel
Usual way
HMI
PLC & HMI
Backup
Usability
Restore
Overview
HMI
Page 24
2012-10-29
Visualization with WinCC V12
PLC
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
12
SIMATIC WinCC V12
How to…
Hardware
Release
Management
Communication
Basic Panels
Backup & restore via Basic Panel
 New item “Service & Commission” available
 Select “Backup” or “Restore”
Maintenance
 Scan for an accessible device or insert IP & connect afterwards
Tag management
 Create a backup or select & restore an existing one
Screens
 Backup will be placed at or restored from PLCs SIMATIC memory card
SCADA
PLC & HMI
Usability
Overview
Page 25
2012-10-29
SIMATIC WinCC V12
New service concept
Hardware
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Comfort Panels
New panel service concept - Comfort Panels
Release
Management
 Image transfer via USB-Stick or SD-Card (FAT32)
Communication
 Replacement of Comfort Panel without engineering system
possible
Maintenance
Tag management
Screens
 TIA Portal / ProSave is still possible
SCADA
PLC & HMI
Usability
Overview
Page 26
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
13
SIMATIC WinCC V12
How to…
Hardware
Comfort Panels
Create a HMI OS image
Release
Management
Communication
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 27
2012-10-29
SIMATIC WinCC V12
How to…
Visualization with WinCC V12
Comfort Panels
Hardware
Create a HMI OS image
Release
Management
1
Select destination device & create
HMI OS image on memory card
2
Choose matching display
if necessary adapt restore settings
Communication
Maintenance
Tag management
Screens
SCADA
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
 It is also possible to download
various images on device
PLC & HMI
Usability
Overview
Page 28
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
14
SIMATIC WinCC V12
How to…
Hardware
Comfort Panels
Update OS from SD card or USB stick
Release
Management
Communication
Maintenance
1
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 29
2012-10-29
SIMATIC WinCC V12
How to…
Hardware
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Comfort Panels
Update OS from SD card or USB stick
Release
Management
Communication
Maintenance
1
Tag management
2
Screens
SCADA
PLC & HMI
Usability
Overview
Page 30
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
15
SIMATIC WinCC V12
How to…
Hardware
Comfort Panels
Update OS from SD card or USB stick
Release
Management
Communication
Maintenance
1
Tag management
2
Screens
3
SCADA
PLC & HMI
Usability
Overview
Page 31
2012-10-29
SIMATIC WinCC V12
How to…
Hardware
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Comfort Panels
Update OS from SD card or USB stick
Release
Management
Communication
Maintenance
1
Tag management
2
Screens
3
SCADA
4
PLC & HMI
Usability
Overview
Page 32
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
16
SIMATIC WinCC V12
Integrated connections
Hardware
Release
Management
Addressing with integrated connections
 Absolute addressing: connected to address, tag name not necessary
 searches automatically (reconnect to PLC) for tag name
Communication
Maintenance
Tag management
Screens
 Symbolic addressing: connected to symbolic name, no relation to absolute address
 supported by S7-1200 and S7-1500 PLCs
SCADA
PLC & HMI
Usability
Overview
Page 33
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Integrated connections
Hardware
Release
Management
Addressing PLC tags symbolically
 Insert tags from standard DBs, optimized DBs or tag tables
Communication
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
NO absolute address
in this access mode
Page 34
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
17
SIMATIC WinCC V12
Integrated connections
Hardware
Release
Management
Communication
Maintenance
Default settings for addressing PLC tags
 Change default access method in TIA Portal settings
 Defines whether PLC tags are automatically addressed absolutely or symbolically
 Access method can also be changed by hand afterwards
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 35
2012-10-29
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
SIMATIC WinCC V12
Integrated connections
Hardware
Release
Management
Communication
Maintenance
Use cases – Benefits of symbolic addressing:
PLC:
changes
 HMI:
not necessary
 PLC tags:
Tag management
Change address &
PLC
Screens
SCADA
PLC & HMI
Usability
 DB (standard or optimized) elements:
Overview
Add a row above &
Page 36
2012-10-29
Visualization with WinCC V12
PLC
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
18
SIMATIC WinCC V12
Integrated connections
Hardware
Release
Management
Communication
Maintenance
Use cases – Benefits of symbolic addressing:
PLC:
changes
 HMI:
not necessary
 Name of PLC tags:
Tag management
Change name &
Screens
PLC
SCADA
PLC & HMI
Usability
Overview
Page 37
Tag is updated
automatically
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Data types
Hardware
Release
Management
Communication
Support of 64-bit data types in HMI
 Communication with S7-1200 or S7-1500 64-bit tags
 Higher resolution with usage of LREAL data types
Maintenance
Real
Floating-point number 32-bit IEEE 754
+-3.402823e+38
Tag management
LReal
Floating-point number 64-bit IEEE 754
+-1.79769313486231e+308
Screens
SCADA
PLC & HMI
Usability
Overview
Page 38
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
19
SIMATIC WinCC V12
PLC tags restrictions
Hardware
Release
Management
Communication
Maintenance
Restricted access to PLC tags
 Visible in HMI:
Shows whether the tag is visible by default
 Accessible from HMI:
Shows whether HMI can access this tag
Tag management
Screens
 even copy & paste does not insert those tags into tag tables
SCADA
PLC tag table
HMI tag table: browse PLC tag
PLC & HMI
Usability
Overview
Page 39
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
PLC tags restrictions
Hardware
Release
Management
Communication
Maintenance
Restricted access to PLC tags
 Visible in HMI:
Shows whether the tag is visible by default
 Accessible from HMI:
Shows whether HMI can access this tag
Tag management
Screens
 even copy & paste does not insert those tags into tag tables
SCADA
PLC tag table
HMI tag table: browse PLC tag
PLC & HMI
Usability
Overview
Page 40
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
20
SIMATIC WinCC V12
PLC tags restrictions
Hardware
Release
Management
Communication
Maintenance
Drag & Drop structured PLC tags to HMI
 Each element is implemented as an individual HMI tag (not structured)
 HMI tag automatically connected to PLC tag
 Existing HMI connection is used or a new one will be created
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Only tags with accessible
flag are copied
Page 41
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
PLC tags restrictions
Hardware
Release
Management
Communication
Drag & Drop structured PLC tags to HMI
 Copy also of complex structures & paste as single tags in HMI tag table
 Only accessible elements are copied even if the flag is set “deep” in the structure
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 42
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
21
SIMATIC WinCC V12
HMI protection levels
PLC and HMI protection levels
Hardware
 S7-1500 PLC
Release
Management
 Protection level 4 affects all HMI devices
Communication
 Access granted with password from level 1, 2 or 3
Maintenance

 Password defined at the HMI connection
Tag management
 Basic Panels, Mobile Panel 277, Multi Panels x77, Comfort Panel, RT
Advanced & Professional support access via password
Screens
SCADA
PLC & HMI
Usability
Overview
Only in this level a
password is needed
Page 43
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
How to…
PLC and HMI protection levels
Hardware
 Password is needed in case of protection level 4
Release
Management
Communication
Maintenance
Tag management
Screens
SCADA
PLC & HMI
1
Usability
Overview
Set password to grant
access to PLC
Page 44
2012-10-29
Visualization with WinCC V12
2
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
22
SIMATIC WinCC V12
HMI protection levels
Hardware
Release
Management
Communication
HMI
HMI
HMI
HMI
No
password
Level 1-3
password
No
password
wrong
password
S7-1500
S7-1500
S7-1500
S7-1500
Level 1-3
Level 4
Level 4
Level 1-4
Maintenance
RT
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 45
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Screens – Overview
Hardware
Release
Management
Communication
Maintenance
Tag management
Screens
SCADA
Object type
displayed behind
name
Adjust zoom
PLC & HMI
Usability
New tab
Overview
New icons
Page 46
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
23
SIMATIC WinCC V12
Languages & multilingual texts
Hardware
Release
Management
Communication
Maintenance
Tag management
Easier handling of multilingual texts
 Edit texts of screen, whole groups or multi selections
 Copy and paste of texts
 All in one window without changing editing language
 Languages have to be activated in languages & resources
Screens
SCADA
PLC & HMI
Usability
Overview
Page 47
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Rewiring
Hardware
Release
Management
Communication
Change object references similar to rewiring functionality from WinCC flexible
 Shows tag references within screens
 Finds tags with properties or events as point of use
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 48
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
24
SIMATIC WinCC V12
How to…
Use cases:
 Same screens for different DBs
Library
Screen template
Screen_1
I/O field
Connect tags
DB1_status
Copy screen
DB1_min
DB1_max
2012-10-29
DB1_status
DB1_min
DB1_max
DB2
DB1
Configuration
Screen_2
Change object reference
Screen_2
Screen_1
Page 49
DB1_status
DB1_min
DB1_max
rewire
Find & replace
string DB1 by DB2
rewire
DB2_status
DB2_min
DB2_max
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
SIMATIC WinCC V12
How to…
Change object references …
 Precondition: well organized tags
 Open from context menu
 Find and replace parts of tag names
2
3
1
4
Page 50
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
25
SIMATIC WinCC V12
Reconnect PLC tags
Hardware
Release
Management
Communication
Reconnect PLC tags similar to WinCC flexible based on:
 Symbolic addresses
 Absolute addresses
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 51
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Reconnect PLC tags
Reconnect if the path / tag name matches
The connection is marked red because…
 …PLC connection changed
 Reconnect checks validation in new connection path
 …PLC connection changed & address changed
 Reconnect checks validation in new connection path &
updates the address
The path of the PLC tag matches
The connection has to be already
created
Page 52
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
26
SIMATIC WinCC V12
Reconnect PLC tags
Reconnect if the address matches
The field “PLC tag” is empty because...
 …tags have been imported
 …a copied tag table from library
 Reconnect finds matching tag names
The connection is marked red because…
The address of the PLC tag matches
 …PLC connection changed
 Reconnect checks validation in new connection path
The connection has to be already
created
Page 53
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Runtime file browser
Hardware
Release
Management
Communication
Maintenance
Runtime file browser
 Useful to transfer a file’s path to a tag by selecting the file in the browser
 The tag can be used to open webpages, PDFs, etc.
 Available for Comfort Panels and Runtime Advanced
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 54
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
27
SIMATIC WinCC V12
How to…
Hardware
Release
Management
Communication
Maintenance
Configuration
 Use new system function “OpenFileBrowser”, e.g. click event at a button
 Use “Initial directory” for browsing location
 Select a tag (Wstring) to configure the output path: Path (Out)
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 55
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Offline download
Hardware
Release
Management
Communication
Download to device
 New: Download single stations to a local path
or an external device
Engineering Station
WinCC Client
 Usual way: Download to network path
Maintenance
Tag management
Screens
SCADA
PLC & HMI
RT
Usability
Overview
Page 56
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
28
SIMATIC WinCC V12
Run as service
Hardware
Release
Management
Communication
WinCC as service:
 WinCC servers as service, Clients interactively
 WinCC server is located in a separate room, no user needs to be logged in
Maintenance
 WinCC Runtime starts automatically with Windows
Tag management
 Monitoring and control of the WinCC project from the clients / Web clients
Screens
 Dedicated Web Navigator or Data Monitor server as service
SCADA
PLC & HMI
Usability
Overview
separated
room
Page 57
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
How to…
Hardware
Release
Management
Communication
Maintenance
Tag management
Configuration
 Open WinCC RT Start
 Select a project
 Switch to tab Operation mode
 Insert Windows user and password
Screens
SCADA
Activate service
PLC & HMI
Usability
Overview
Page 58
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
29
SIMATIC WinCC V12
Vertical fonts
Hardware
Release
Management
Communication
Maintenance
Vertical fonts
 Define a font in vertical reading direction
 “@” in front of the name signals a vertical font
 Set text orientation vertical
Tag management
Screens
SCADA
PLC & HMI
1
Usability
2
Overview
Page 59
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
PLC & HMI Engineer working together
Hardware
Release
Management
Slides will be available for S7-300, S7-1200 & S7-1500
 Slides are currently in work
Communication
 Published as newsletter (HMI- and TIA- Promotors)
Maintenance
 Published as FAQ
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 60
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
30
SIMATIC WinCC V12
Comfort Panel migration
Integrated Classic project available
Switch to STEP 7 and WinCC V11
WinCC
flexible
WinCC
(TIA Portal)
STEP 7
classic
STEP 7
(TIA Portal)
New project
Use of STEP 7 and WinCC V11
 Migration of project
 Device change
 Use of TIA Portal
WinCC
(TIA Portal)
 Use of TIA Portal Benefits
STEP 7
(TIA Portal)
Benefits
Integrated Classic project available
Switch to WinCC V11
WinCC
flexible
WinCC
(TIA Portal)
STEP 7
classic
STEP 7
classic
New project
Use of STEP 7 classic and WinCC V11
 Deintegration
 Migration of WinCC
flexible
WinCC
(TIA Portal)
STEP 7
classic
 Export of STEP 7 Tags
 Convert tags with TagConverter
 Import in WinCC V11
 Device change
Page 61
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Working with STEP 7 classic & WinCC V12 together
Hardware
WinCC (TIA Portal) and STEP 7 classic
Release
Management
Existing STEP 7 with new WinCC (TIA Portal) project
Communication
1. Create the HMI in WinCC (TIA Portal)
Maintenance
2. Export the needed tags from STEP 7
Tag management
3. Convert the export file with WinCC Tag Converter (Link)
Screens
4. Import the converted file in WinCC (TIA Portal)
SCADA
PLC & HMI
Usability
Overview
 All tags are converted with absolute address
 Changes on some single tags in STEP 7 project can be updated manually
 „big changes“ can be updated with the help of Tag Converter
No support of reporting system errors (RSE) & controller alarms
Page 62
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
31
SIMATIC WinCC V12
WinCC Tag Converter – How to…
Export of tags from STEP 7 classic
Single data blocks
 Open the data block
 File  Print  „Generic / Text only“ printer
 Input path \ filename.txt in the following dialog
Page 63
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
WinCC Tag Converter – How to…
Export of tags from STEP 7 classic
Single or several data blocks
 „Generic / Text only“ printer is the windows standard printer
 Right mouse on the needed data blocks
 Print  Object Content
 Input path \ filename.txt in the following dialog for each DB
Page 64
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
32
SIMATIC WinCC V12
WinCC Tag Converter – How to…
Export of tags from STEP 7 classic
Symbol table
 Open symbol table
 Symbol Table  export
 Input path \ filename.asc in the following dialog
Page 65
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
WinCC Tag Converter – How to…
Export of tags from STEP 7 classic
Symbol table
 Open symbol table
 Symbol Table  export
 Input path \ filename.asc in the following dialog
Page 66
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
33
SIMATIC WinCC V12
WinCC Tag Converter – How to…
Conversion of tags with WinCC Tag Converter
 Converts the tag export files of SIMATIC Manager, Rockwell (Allen-Bradley)
and Schneider/Modicon in the import-format of WinCC (TIA Portal)
WinCC Tag Converter
converted file ready
to import in WinCC
export file from
PLC programming Tool
Page 67
2012-10-29
Industry Online Support:
Deutsch
English
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
SIMATIC WinCC V12
WinCC Tag Converter – How to…
Import of tags to WinCC (TIA Portal)
 The converted file with the tags can easily be imported.
Hint: the PLC connection should be created in WinCC previously
start
tag import
Converted file:
HMI Tags  Show all tags:
Page 68
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
34
SIMATIC WinCC V12
Usability
Hardware
Release
Management
Communication
Advanced color picker
 Not every color is supported by each Panel
 Therefore TIA Portal adapts colors & displays the
current, the selected and the adapted color in a preview
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Selected color
Usability
Overview
Page 69
Adapted color,
details see tooltip
2012-10-29
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
Visualization with WinCC V12
SIMATIC WinCC V12
Usability
Hardware
Cross references
Release
Management
 Number of locations where the object is used
Communication
Maintenance
Tag management
Screens
SCADA
2
PLC & HMI
Usability
Overview
1
Page 70
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
35
SIMATIC WinCC V12
Usability
Hardware
Release
Management
Move object to the next snap line
 Use “s” + “arrow key” to move object
Communication
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 71
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Usability
Hardware
Release
Management
New system function in SCADA
 Set language directly or toggle
Communication
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 72
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
36
SIMATIC WinCC V12
Usability
Hardware
Events with improved look and feel
Release
Management
Communication
Maintenance
Tag management
Screens
SCADA
V11  V12
PLC & HMI
Usability
Overview
Page 73
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Usability
Hardware
Release
Management
Communication
Two new expression templates
 Expressions AND & OR added
 Additional space for expressions
Maintenance
Tag management
Screens
SCADA
Enough space for long
expression
PLC & HMI
Usability
Overview
Page 74
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
37
SIMATIC WinCC V12
Usability
Hardware
Release
Management
Animate property: Support of floating points (range type)
 Including new elements: Brackets & intervals
Communication
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Bracket
Example
If the process value (x) is …
…than color is …
[…-…]
[0 - 0.25]
0 ≤ x ≤ 0.25
black
]…-…]
]0.25 - 0.5]
0.25 < x ≤ 0.50
red
]…-…[
]0.5 - 1[
0.5 < x < 1
yellow
Usability
Overview
Page 75
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Usability
Hardware
Release
Management
Communication
Support of floating points
 Use case expression: calculations
 Overlapping areas are invalid and marked red
Maintenance
Tag management
Screens
SCADA
PLC & HMI
RT V12
Usability
Overview
Page 76
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
38
SIMATIC WinCC V12
Usability
Hardware
Release
Management
Communication
Screen window
 Improved handling
 Select “Open screen” to switch to displayed screen
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 77
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Usability
Hardware
Release
Management
Faceplates
 Blue bold colored text indicates the usage of a property
Communication
Maintenance
Tag management
Screens
SCADA
PLC & HMI
Usability
Overview
Page 78
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
39
SIMATIC WinCC V12
Overview
Hardware
Release
Management
Communication
Feature
Panels
RT Advanced
RT Professional
-
-
-
Offline transfer
-
-
Run as service
-
-
Hardware news
S7-1500 driver
Symbolic addressing
Maintenance
Tag management
64-bit data types
Screens
Restricted access to PLC tags
SCADA
Protection levels
PLC & HMI
New tab for multilingual languages
Usability
Change object reference (rewire)
Overview
Page 79
Reconnect tags
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
SIMATIC WinCC V12
Overview
Hardware
Release
Management
Communication
Feature
Panels
RT Advanced
System diagnostic viewer
Backup & restore an image at PLC
OS Update via external devices
RT Professional
-
only Basic
-
-
only Comfort
-
-
-
-
Maintenance
Tag management
Advanced color picker
Screens
Counting in cross references
SCADA
Move object to snap lines via keyboard
PLC & HMI
Advanced context menu for events
Usability
New expression templates
-
-
Floating points for property animation
-
-
Vertical fonts
-
-
Improved handling of screen windows
-
-
-
-
Overview
Faceplates: colored texts
Page 80
2012-10-29
Visualization with WinCC V12
For internal use only / © Siemens AG 2012. All Rights Reserved.
I IA AS S SUP FA
40