SIMATIC WinCC V12 Engineering for all HMI-Systems
Transcription
SIMATIC WinCC V12 Engineering for all HMI-Systems
SIMATIC WinCC V12 Engineering for all HMI-Systems Release Management Communication Maintenance Tag management Engineering Edition Hardware WinCC Professional 512, 4k, max. PowerTags WinCC Advanced WinCC Comfort WinCC Basic Screens SCADA Basic Panels PLC & HMI Comfort Panels, Mobile Panels Panel PC, Standard PC SCADA Overview Panel Usability Single Station … based on WinCC flexible RT Page 1 2012-10-29 SCADA System … based on WinCC V7 Runtime For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 Maintenance Tag management Screens SCADA SIMATIC HMI Basic Panels KP300 Basic KP400 Basic New KTP 400 Basic, KTP 600 Basic, KTP 1000 Basic, TP 1500 Basic SIMATIC HMI Panels / Multi Panels OP73, OP77, TP177, OP177, TP277, OP277, MP177, MP277, MP377 SIMATIC HMI Mobile Panels PLC & HMI Mobile Panel 177, Mobile Panel 277 Mobile Panel 277 IWLAN V2 Usability SIMATIC HMI Comfort Panels Overview Page 2 WinCC Basic Communication WinCC Comfort Release Management WinCC Advanced Hardware WinCC Professional SIMATIC WinCC V12 Supported hardware KTP 400 Comfort, KP 400 Comfort, TP 700 Comfort, KP 700 Comfort, TP 900 Comfort, KP 900 Comfort TP 1200 Comfort, KP1200 Comfort TP 1500 Comfort, KP1500 Comfort TP 1900 Comfort, TP2200 Comfort 2012-10-29 Visualization with WinCC V12 New For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 1 Release Management Communication Maintenance Tag management Screens WinCC Advanced Hardware WinCC Professional SIMATIC WinCC V12 Supported hardware SCADA PLC & HMI SIMATIC WinCC Runtime Advanced (PC-based single station) …with 128, 512, 2k, 4k PowerTags IPC227D, IPC277D IPC427C/D, IPC477C/D IPC577C IPC627C, IPC827C IPC677C IPC647C, IPC847C IPC547D Standard PC SIMATIC WinCC Runtime Professional (PC-based SCADA) Usability …with 128, 512, 2k, 4k, 8k, 64k PowerTags Overview IPC427C/D, IPC477C/D (Client) IPC577C (Client) IPC627C, IPC827C IPC677C IPC647C, IPC847C IPC547C/D Standard PC Page 3 2012-10-29 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 SIMATIC WinCC V12 Comfort Panels – Overview Hardware Release Management Communication Maintenance Display size 4''W 7''W 4,3'' 7,0'' Resolution 480x272 Prozessor New New New 19''W 22''W 9''W 12''W 15''W 9,0'' 12,1'' 15,4'' 800x480 1280x800 18,5'' 21,5'' 1366x768 1920x1080 ARM 532 MHz x86 500 MHz x86 1GHz Project memory 4 MB 12 MB 24 MB Screens Tags 1024 2048 4096 SCADA Messages 2000 4000 6000 PLC & HMI Recipes 100 / 200 / 200 * 300/ 500 / 1000 * 500 / 1000 / 2000 500 500 Tag management Usability Overview Images Archives Scripts 750 10 / 10.000 ** 50 Viewer / multimedia 50 / 50.000 ** 100 200 Internet Explorer, PDF, Word- and Excelviewer, Multimedia Player Sm@rtServer yes *) recipes / data sets per recipe / entries per data set Page 4 2012-10-29 Visualization with WinCC V12 **) Archive / entries per archive For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 2 SIMATIC WinCC V12 Industrial Thin Client – SIMATIC ITC New SIMATIC ITC Resolution ITC1200 ITC1500 12" Touch Widescreen 15" Touch Widescreen 1280 x 800 ITC1900 1280 x 800 Display 22" Touch Widescreen 1366x768 1920 x 1080 high resolution, 16 Mio. colors, 100% dimmable CPU Intel Celeron 1,2 GHz Interfaces 1 x GBit LAN , 2 x USB 2.0 (backside) Webbrowser HTML5, XML, CSS, JavaScript Protocols Sm@rtServer, RDP, VNC Active connections 5 Power supply 24V DC Certificates CE, cULus, C-Tick, ATEX Zone 2/22 (planned) Produkt link: 60521782 Page 5 ITC2200 19” Touch Widescreen 2012-10-29 FAQ: 63258317 Produktvideo For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 SIMATIC WinCC V12 1 – Compatibility mode Hardware Release Management TIA Portal V12 support for the Service use case Exception: Compile of Runtime Professional V11 Communication Maintenance WinCC ES V11 SP2 Tag management WinCC ES V12 (compatibility mode) V11 Proj. RT V11 SP2 Screens RT V11 SP2 V12 Upgrade Proj. WinCC ES V12 RT V11 SP2 RT V12 SCADA PLC & HMI RT V11 SP2 Usability RT V12 Overview Panel / SCADA 1 Page 6 2012-10-29 Visualization with WinCC V12 Panel / SCADA 2 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 3 SIMATIC WinCC V12 1 – Compatibility mode Work on V11 projects with V12 V11 project can be modified with different versions of the engineering system Saved projects can be opened with TIA Portal V11 SP2 again WinCC V11 SP2 V11 Proj. Page 7 Engineering system Engineering system Functionality and features of TIA Portal V11 SP2 products are supported 2012-10-29 WinCC V12 (V11 compatibility mode) *Compile and download not supported for Runtime Professional V11 Open project supported Edit/compile/download devices supported* For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 SIMATIC WinCC V12 2 – Upgrade to V12 Hardware Release Management Use of new functionality coming with WinCC V12 Exception: Compile As Runtime Professional V11 Communication WinCC ES V11 SP2 Maintenance Tag management WinCC ES V12 (compatibility mode) V11 Proj. RT V11 SP2 Screens RT V11 SP2 V12 Upgrade Proj. WinCC ES V12 RT V11 SP2 RT V12 SCADA PLC & HMI RT V11 SP2 Usability RT V12 Overview Panel / SCADA 1 Page 8 2012-10-29 Visualization with WinCC V12 Panel / SCADA 2 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 4 SIMATIC WinCC V12 2 - Upgrade to V12 Hardware Use of new functionality coming with WinCC V12 Release Management Use of new functions (e.g. S7-1500) V11 project must be upgraded to V12 Communication Panels and RT Advanced remain in version 11 for service use cases Project upgrade includes upgrade of RT Professional Maintenance Engineering system Tag management Screens SCADA PLC & HMI Upgraded V11 project or newly created V12 project can only be opened with TIA Portal V12 products WinCC V12 Usability Overview Save (V12) project supported V11 Proj. Page 9 2012-10-29 V12 Proj. Edit/compile/download devices supported For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 SIMATIC WinCC V12 2 – How to… Hardware Release Management Communication Maintenance Upgrade V11 projects to V12 V11 project file remains available V12 project build in a new folder named “..._V12” No downgrade afterwards, no more use in TIA Portal V11 Tag management Screens SCADA 3 2 PLC & HMI 1 Upgrade to V12 Usability Overview Page 10 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 5 SIMATIC WinCC V12 3 – V11 devices in TIA Portal V12 Hardware Release Management Create, modify and compile V11 devices in V12 project Exception: Compile As Runtime Professional V11 Communication Maintenance WinCC ES V12 (compatibility mode) V11 Proj. WinCC ES V11 SP2 Tag management RT V11 SP2 Screens V12 Upgrade Proj. RT V11 SP2 WinCC ES V12 RT V11 SP2 RT V12 SCADA PLC & HMI RT V11 Usability RT V12 Overview Panel / SCADA 1 Page 11 2012-10-29 Panel / SCADA 2 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 SIMATIC WinCC V12 3 – V11 devices in TIA Portal V12 Hardware No upgrade of Panels FW forced by new version of engineering system Release Management WinCC V12 can configure devices with RT versions V11 and V12 Communication Version change (V11↔V12) is handled similar to Device type change Configured RT version decides about supported functionality in editors Maintenance Engineering system Tag management Screens SCADA PLC & HMI WinCC V12 Compile and download not supported for Runtime Professional V11 Usability Overview V11 device V12 Proj. Page 12 2012-10-29 V12 device Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 6 SIMATIC WinCC V12 Upgrade process Hardware Release Management Communication Maintenance Upgrade V11 projects to V12 V11 project file remains available V12 project build in a new folder named “..._V12” No downgrade afterwards, no more use in TIA Portal V11 Tag management Screens SCADA 3 2 PLC & HMI 1 Upgrade to V12 Usability Overview Page 13 2012-10-29 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 SIMATIC WinCC V12 V11 devices in TIA Portal V12 Hardware No upgrade of Panels FW forced by new version of engineering system Release Management WinCC V12 can configure devices with RT versions V11 and V12 Communication Version change (V11↔V12) is handled similar to Device type change Configured RT version decides about supported functionality in editors Maintenance Engineering system Tag management Screens SCADA PLC & HMI WinCC V12 Compile and download not supported for Runtime Professional V11 Usability Overview V11 device V12 Proj. Page 14 2012-10-29 V12 device Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 7 SIMATIC WinCC V12 Select RT version Configurable RT version in “Add new device” dialog Configurable RT version in Hardware catalog Page 15 2012-10-29 Visualization with WinCC V12 Configured RT version in Catalog information of configured device (EditorFor Devices networks) internal&use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Change RT version Change device type / version for selected device Page 16 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 8 SIMATIC WinCC V12 Communication drivers Hardware Release Management Communication Maintenance WinCC Basic offers drivers for: SIMATIC S7-1500 New SIMATIC S7-1200 SIMATIC S7-300/400 Tag management SIMATIC S7-200 Screens LOGO! SCADA Allen-Bradley DF1, EtherNet/IP PLC & HMI Mitsubishi MC TCP/IP Usability Modicon Modbus TCP/IP New Overview No support for SIMATIC S5 Page 17 2012-10-29 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 SIMATIC WinCC V12 Communication drivers Hardware Release Management Communication Maintenance WinCC Comfort / Advanced offers drivers for: SIMATIC S7-1500 New SIMATIC S7-1200 SIMATIC S7-300/400 Tag management SIMATIC S7-200 Screens LOGO! SCADA Allen-Bradley DF1, EtherNet/IP PLC & HMI Mitsubishi FX, MC TCP/IP Usability Modicon Modbus RTU, TCP/IP Overview New Omron Host Link Communication driver OPC (DA, XML DA, UA) No support for SIMATIC S5 Page 18 2012-10-29 Visualization with WinCC V12 * SINUMERIK Integrate Create MyHMI / WinCC option has to be installed For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 9 SIMATIC WinCC V12 Process Communication Driver What’s new: LOGO! Hardware Release Management Communication Maintenance Communication driver for LOGO! Communication interface Ethernet Available in HMI devices Tag management Basic PN Panels Screens Mobile Panels 177PN, 277 SCADA Multi Panels PLC & HMI Comfort Panels Usability Runtime Advanced Overview Data Type and address range Page 19 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Communication drivers Hardware Release Management Communication Maintenance WinCC Professional offers drivers for: SIMATIC S7-1500 New SIMATIC S7-1200 SIMATIC S7-300/400 Tag management Allen-Bradley EtherNet/IP Screens Mitsubishi MC TCP/IP SCADA Modicon Modbus TCP/IP PLC & HMI OPC (DA / XML DA) Usability Overview No support for SIMATIC S5 Communication driver Page 20 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 10 SIMATIC WinCC V12 Diagnostic services Hardware STEP 7 Release Management HMI WebServer CPU-Display Communication Maintenance Tag management Screens SCADA PLC & HMI Usability Overview Page 21 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Diagnostic services – Display at Panels / RT Advanced Hardware Release Management Communication System diagnostics viewer Displays the overview of accessible devices and the system state of the plant Switch between device and detail view Maintenance Same concept at Comfort Panels, RT Advanced, CPU display and CPU webserver Tag management There is also a buffer viewer available for Basic Panels Screens SCADA PLC & HMI Usability Overview Page 22 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 11 SIMATIC WinCC V12 Diagnostic services – Display at Panels / RT Advanced Hardware Release Management Communication System diagnostics viewer – detect errors in plant Click forward through structure to find out the source of an error Autofocus on faulty device Maintenance Tag management Screens SCADA PLC & HMI Usability Overview Page 23 2012-10-29 SIMATIC WinCC V12 New service concept Hardware Release Management Communication Maintenance Tag management Screens SCADA Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Basic Panels New panel service concept - Basic Panels New Runtime project stored on S7-1500 In the case of a device replacement the HMI backup can be uploaded from the PLC directly into the new panel Usual way HMI PLC & HMI Backup Usability Restore Overview HMI Page 24 2012-10-29 Visualization with WinCC V12 PLC For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 12 SIMATIC WinCC V12 How to… Hardware Release Management Communication Basic Panels Backup & restore via Basic Panel New item “Service & Commission” available Select “Backup” or “Restore” Maintenance Scan for an accessible device or insert IP & connect afterwards Tag management Create a backup or select & restore an existing one Screens Backup will be placed at or restored from PLCs SIMATIC memory card SCADA PLC & HMI Usability Overview Page 25 2012-10-29 SIMATIC WinCC V12 New service concept Hardware Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Comfort Panels New panel service concept - Comfort Panels Release Management Image transfer via USB-Stick or SD-Card (FAT32) Communication Replacement of Comfort Panel without engineering system possible Maintenance Tag management Screens TIA Portal / ProSave is still possible SCADA PLC & HMI Usability Overview Page 26 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 13 SIMATIC WinCC V12 How to… Hardware Comfort Panels Create a HMI OS image Release Management Communication Maintenance Tag management Screens SCADA PLC & HMI Usability Overview Page 27 2012-10-29 SIMATIC WinCC V12 How to… Visualization with WinCC V12 Comfort Panels Hardware Create a HMI OS image Release Management 1 Select destination device & create HMI OS image on memory card 2 Choose matching display if necessary adapt restore settings Communication Maintenance Tag management Screens SCADA For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA It is also possible to download various images on device PLC & HMI Usability Overview Page 28 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 14 SIMATIC WinCC V12 How to… Hardware Comfort Panels Update OS from SD card or USB stick Release Management Communication Maintenance 1 Tag management Screens SCADA PLC & HMI Usability Overview Page 29 2012-10-29 SIMATIC WinCC V12 How to… Hardware Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Comfort Panels Update OS from SD card or USB stick Release Management Communication Maintenance 1 Tag management 2 Screens SCADA PLC & HMI Usability Overview Page 30 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 15 SIMATIC WinCC V12 How to… Hardware Comfort Panels Update OS from SD card or USB stick Release Management Communication Maintenance 1 Tag management 2 Screens 3 SCADA PLC & HMI Usability Overview Page 31 2012-10-29 SIMATIC WinCC V12 How to… Hardware Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Comfort Panels Update OS from SD card or USB stick Release Management Communication Maintenance 1 Tag management 2 Screens 3 SCADA 4 PLC & HMI Usability Overview Page 32 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 16 SIMATIC WinCC V12 Integrated connections Hardware Release Management Addressing with integrated connections Absolute addressing: connected to address, tag name not necessary searches automatically (reconnect to PLC) for tag name Communication Maintenance Tag management Screens Symbolic addressing: connected to symbolic name, no relation to absolute address supported by S7-1200 and S7-1500 PLCs SCADA PLC & HMI Usability Overview Page 33 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Integrated connections Hardware Release Management Addressing PLC tags symbolically Insert tags from standard DBs, optimized DBs or tag tables Communication Maintenance Tag management Screens SCADA PLC & HMI Usability Overview NO absolute address in this access mode Page 34 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 17 SIMATIC WinCC V12 Integrated connections Hardware Release Management Communication Maintenance Default settings for addressing PLC tags Change default access method in TIA Portal settings Defines whether PLC tags are automatically addressed absolutely or symbolically Access method can also be changed by hand afterwards Tag management Screens SCADA PLC & HMI Usability Overview Page 35 2012-10-29 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 SIMATIC WinCC V12 Integrated connections Hardware Release Management Communication Maintenance Use cases – Benefits of symbolic addressing: PLC: changes HMI: not necessary PLC tags: Tag management Change address & PLC Screens SCADA PLC & HMI Usability DB (standard or optimized) elements: Overview Add a row above & Page 36 2012-10-29 Visualization with WinCC V12 PLC For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 18 SIMATIC WinCC V12 Integrated connections Hardware Release Management Communication Maintenance Use cases – Benefits of symbolic addressing: PLC: changes HMI: not necessary Name of PLC tags: Tag management Change name & Screens PLC SCADA PLC & HMI Usability Overview Page 37 Tag is updated automatically 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Data types Hardware Release Management Communication Support of 64-bit data types in HMI Communication with S7-1200 or S7-1500 64-bit tags Higher resolution with usage of LREAL data types Maintenance Real Floating-point number 32-bit IEEE 754 +-3.402823e+38 Tag management LReal Floating-point number 64-bit IEEE 754 +-1.79769313486231e+308 Screens SCADA PLC & HMI Usability Overview Page 38 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 19 SIMATIC WinCC V12 PLC tags restrictions Hardware Release Management Communication Maintenance Restricted access to PLC tags Visible in HMI: Shows whether the tag is visible by default Accessible from HMI: Shows whether HMI can access this tag Tag management Screens even copy & paste does not insert those tags into tag tables SCADA PLC tag table HMI tag table: browse PLC tag PLC & HMI Usability Overview Page 39 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 PLC tags restrictions Hardware Release Management Communication Maintenance Restricted access to PLC tags Visible in HMI: Shows whether the tag is visible by default Accessible from HMI: Shows whether HMI can access this tag Tag management Screens even copy & paste does not insert those tags into tag tables SCADA PLC tag table HMI tag table: browse PLC tag PLC & HMI Usability Overview Page 40 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 20 SIMATIC WinCC V12 PLC tags restrictions Hardware Release Management Communication Maintenance Drag & Drop structured PLC tags to HMI Each element is implemented as an individual HMI tag (not structured) HMI tag automatically connected to PLC tag Existing HMI connection is used or a new one will be created Tag management Screens SCADA PLC & HMI Usability Overview Only tags with accessible flag are copied Page 41 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 PLC tags restrictions Hardware Release Management Communication Drag & Drop structured PLC tags to HMI Copy also of complex structures & paste as single tags in HMI tag table Only accessible elements are copied even if the flag is set “deep” in the structure Maintenance Tag management Screens SCADA PLC & HMI Usability Overview Page 42 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 21 SIMATIC WinCC V12 HMI protection levels PLC and HMI protection levels Hardware S7-1500 PLC Release Management Protection level 4 affects all HMI devices Communication Access granted with password from level 1, 2 or 3 Maintenance Password defined at the HMI connection Tag management Basic Panels, Mobile Panel 277, Multi Panels x77, Comfort Panel, RT Advanced & Professional support access via password Screens SCADA PLC & HMI Usability Overview Only in this level a password is needed Page 43 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 How to… PLC and HMI protection levels Hardware Password is needed in case of protection level 4 Release Management Communication Maintenance Tag management Screens SCADA PLC & HMI 1 Usability Overview Set password to grant access to PLC Page 44 2012-10-29 Visualization with WinCC V12 2 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 22 SIMATIC WinCC V12 HMI protection levels Hardware Release Management Communication HMI HMI HMI HMI No password Level 1-3 password No password wrong password S7-1500 S7-1500 S7-1500 S7-1500 Level 1-3 Level 4 Level 4 Level 1-4 Maintenance RT Tag management Screens SCADA PLC & HMI Usability Overview Page 45 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Screens – Overview Hardware Release Management Communication Maintenance Tag management Screens SCADA Object type displayed behind name Adjust zoom PLC & HMI Usability New tab Overview New icons Page 46 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 23 SIMATIC WinCC V12 Languages & multilingual texts Hardware Release Management Communication Maintenance Tag management Easier handling of multilingual texts Edit texts of screen, whole groups or multi selections Copy and paste of texts All in one window without changing editing language Languages have to be activated in languages & resources Screens SCADA PLC & HMI Usability Overview Page 47 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Rewiring Hardware Release Management Communication Change object references similar to rewiring functionality from WinCC flexible Shows tag references within screens Finds tags with properties or events as point of use Maintenance Tag management Screens SCADA PLC & HMI Usability Overview Page 48 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 24 SIMATIC WinCC V12 How to… Use cases: Same screens for different DBs Library Screen template Screen_1 I/O field Connect tags DB1_status Copy screen DB1_min DB1_max 2012-10-29 DB1_status DB1_min DB1_max DB2 DB1 Configuration Screen_2 Change object reference Screen_2 Screen_1 Page 49 DB1_status DB1_min DB1_max rewire Find & replace string DB1 by DB2 rewire DB2_status DB2_min DB2_max For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 SIMATIC WinCC V12 How to… Change object references … Precondition: well organized tags Open from context menu Find and replace parts of tag names 2 3 1 4 Page 50 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 25 SIMATIC WinCC V12 Reconnect PLC tags Hardware Release Management Communication Reconnect PLC tags similar to WinCC flexible based on: Symbolic addresses Absolute addresses Maintenance Tag management Screens SCADA PLC & HMI Usability Overview Page 51 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Reconnect PLC tags Reconnect if the path / tag name matches The connection is marked red because… …PLC connection changed Reconnect checks validation in new connection path …PLC connection changed & address changed Reconnect checks validation in new connection path & updates the address The path of the PLC tag matches The connection has to be already created Page 52 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 26 SIMATIC WinCC V12 Reconnect PLC tags Reconnect if the address matches The field “PLC tag” is empty because... …tags have been imported …a copied tag table from library Reconnect finds matching tag names The connection is marked red because… The address of the PLC tag matches …PLC connection changed Reconnect checks validation in new connection path The connection has to be already created Page 53 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Runtime file browser Hardware Release Management Communication Maintenance Runtime file browser Useful to transfer a file’s path to a tag by selecting the file in the browser The tag can be used to open webpages, PDFs, etc. Available for Comfort Panels and Runtime Advanced Tag management Screens SCADA PLC & HMI Usability Overview Page 54 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 27 SIMATIC WinCC V12 How to… Hardware Release Management Communication Maintenance Configuration Use new system function “OpenFileBrowser”, e.g. click event at a button Use “Initial directory” for browsing location Select a tag (Wstring) to configure the output path: Path (Out) Tag management Screens SCADA PLC & HMI Usability Overview Page 55 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Offline download Hardware Release Management Communication Download to device New: Download single stations to a local path or an external device Engineering Station WinCC Client Usual way: Download to network path Maintenance Tag management Screens SCADA PLC & HMI RT Usability Overview Page 56 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 28 SIMATIC WinCC V12 Run as service Hardware Release Management Communication WinCC as service: WinCC servers as service, Clients interactively WinCC server is located in a separate room, no user needs to be logged in Maintenance WinCC Runtime starts automatically with Windows Tag management Monitoring and control of the WinCC project from the clients / Web clients Screens Dedicated Web Navigator or Data Monitor server as service SCADA PLC & HMI Usability Overview separated room Page 57 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 How to… Hardware Release Management Communication Maintenance Tag management Configuration Open WinCC RT Start Select a project Switch to tab Operation mode Insert Windows user and password Screens SCADA Activate service PLC & HMI Usability Overview Page 58 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 29 SIMATIC WinCC V12 Vertical fonts Hardware Release Management Communication Maintenance Vertical fonts Define a font in vertical reading direction “@” in front of the name signals a vertical font Set text orientation vertical Tag management Screens SCADA PLC & HMI 1 Usability 2 Overview Page 59 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 PLC & HMI Engineer working together Hardware Release Management Slides will be available for S7-300, S7-1200 & S7-1500 Slides are currently in work Communication Published as newsletter (HMI- and TIA- Promotors) Maintenance Published as FAQ Tag management Screens SCADA PLC & HMI Usability Overview Page 60 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 30 SIMATIC WinCC V12 Comfort Panel migration Integrated Classic project available Switch to STEP 7 and WinCC V11 WinCC flexible WinCC (TIA Portal) STEP 7 classic STEP 7 (TIA Portal) New project Use of STEP 7 and WinCC V11 Migration of project Device change Use of TIA Portal WinCC (TIA Portal) Use of TIA Portal Benefits STEP 7 (TIA Portal) Benefits Integrated Classic project available Switch to WinCC V11 WinCC flexible WinCC (TIA Portal) STEP 7 classic STEP 7 classic New project Use of STEP 7 classic and WinCC V11 Deintegration Migration of WinCC flexible WinCC (TIA Portal) STEP 7 classic Export of STEP 7 Tags Convert tags with TagConverter Import in WinCC V11 Device change Page 61 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Working with STEP 7 classic & WinCC V12 together Hardware WinCC (TIA Portal) and STEP 7 classic Release Management Existing STEP 7 with new WinCC (TIA Portal) project Communication 1. Create the HMI in WinCC (TIA Portal) Maintenance 2. Export the needed tags from STEP 7 Tag management 3. Convert the export file with WinCC Tag Converter (Link) Screens 4. Import the converted file in WinCC (TIA Portal) SCADA PLC & HMI Usability Overview All tags are converted with absolute address Changes on some single tags in STEP 7 project can be updated manually „big changes“ can be updated with the help of Tag Converter No support of reporting system errors (RSE) & controller alarms Page 62 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 31 SIMATIC WinCC V12 WinCC Tag Converter – How to… Export of tags from STEP 7 classic Single data blocks Open the data block File Print „Generic / Text only“ printer Input path \ filename.txt in the following dialog Page 63 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 WinCC Tag Converter – How to… Export of tags from STEP 7 classic Single or several data blocks „Generic / Text only“ printer is the windows standard printer Right mouse on the needed data blocks Print Object Content Input path \ filename.txt in the following dialog for each DB Page 64 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 32 SIMATIC WinCC V12 WinCC Tag Converter – How to… Export of tags from STEP 7 classic Symbol table Open symbol table Symbol Table export Input path \ filename.asc in the following dialog Page 65 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 WinCC Tag Converter – How to… Export of tags from STEP 7 classic Symbol table Open symbol table Symbol Table export Input path \ filename.asc in the following dialog Page 66 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 33 SIMATIC WinCC V12 WinCC Tag Converter – How to… Conversion of tags with WinCC Tag Converter Converts the tag export files of SIMATIC Manager, Rockwell (Allen-Bradley) and Schneider/Modicon in the import-format of WinCC (TIA Portal) WinCC Tag Converter converted file ready to import in WinCC export file from PLC programming Tool Page 67 2012-10-29 Industry Online Support: Deutsch English For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 SIMATIC WinCC V12 WinCC Tag Converter – How to… Import of tags to WinCC (TIA Portal) The converted file with the tags can easily be imported. Hint: the PLC connection should be created in WinCC previously start tag import Converted file: HMI Tags Show all tags: Page 68 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 34 SIMATIC WinCC V12 Usability Hardware Release Management Communication Advanced color picker Not every color is supported by each Panel Therefore TIA Portal adapts colors & displays the current, the selected and the adapted color in a preview Maintenance Tag management Screens SCADA PLC & HMI Selected color Usability Overview Page 69 Adapted color, details see tooltip 2012-10-29 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA Visualization with WinCC V12 SIMATIC WinCC V12 Usability Hardware Cross references Release Management Number of locations where the object is used Communication Maintenance Tag management Screens SCADA 2 PLC & HMI Usability Overview 1 Page 70 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 35 SIMATIC WinCC V12 Usability Hardware Release Management Move object to the next snap line Use “s” + “arrow key” to move object Communication Maintenance Tag management Screens SCADA PLC & HMI Usability Overview Page 71 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Usability Hardware Release Management New system function in SCADA Set language directly or toggle Communication Maintenance Tag management Screens SCADA PLC & HMI Usability Overview Page 72 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 36 SIMATIC WinCC V12 Usability Hardware Events with improved look and feel Release Management Communication Maintenance Tag management Screens SCADA V11 V12 PLC & HMI Usability Overview Page 73 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Usability Hardware Release Management Communication Two new expression templates Expressions AND & OR added Additional space for expressions Maintenance Tag management Screens SCADA Enough space for long expression PLC & HMI Usability Overview Page 74 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 37 SIMATIC WinCC V12 Usability Hardware Release Management Animate property: Support of floating points (range type) Including new elements: Brackets & intervals Communication Maintenance Tag management Screens SCADA PLC & HMI Bracket Example If the process value (x) is … …than color is … […-…] [0 - 0.25] 0 ≤ x ≤ 0.25 black ]…-…] ]0.25 - 0.5] 0.25 < x ≤ 0.50 red ]…-…[ ]0.5 - 1[ 0.5 < x < 1 yellow Usability Overview Page 75 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Usability Hardware Release Management Communication Support of floating points Use case expression: calculations Overlapping areas are invalid and marked red Maintenance Tag management Screens SCADA PLC & HMI RT V12 Usability Overview Page 76 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 38 SIMATIC WinCC V12 Usability Hardware Release Management Communication Screen window Improved handling Select “Open screen” to switch to displayed screen Maintenance Tag management Screens SCADA PLC & HMI Usability Overview Page 77 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Usability Hardware Release Management Faceplates Blue bold colored text indicates the usage of a property Communication Maintenance Tag management Screens SCADA PLC & HMI Usability Overview Page 78 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 39 SIMATIC WinCC V12 Overview Hardware Release Management Communication Feature Panels RT Advanced RT Professional - - - Offline transfer - - Run as service - - Hardware news S7-1500 driver Symbolic addressing Maintenance Tag management 64-bit data types Screens Restricted access to PLC tags SCADA Protection levels PLC & HMI New tab for multilingual languages Usability Change object reference (rewire) Overview Page 79 Reconnect tags 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA SIMATIC WinCC V12 Overview Hardware Release Management Communication Feature Panels RT Advanced System diagnostic viewer Backup & restore an image at PLC OS Update via external devices RT Professional - only Basic - - only Comfort - - - - Maintenance Tag management Advanced color picker Screens Counting in cross references SCADA Move object to snap lines via keyboard PLC & HMI Advanced context menu for events Usability New expression templates - - Floating points for property animation - - Vertical fonts - - Improved handling of screen windows - - - - Overview Faceplates: colored texts Page 80 2012-10-29 Visualization with WinCC V12 For internal use only / © Siemens AG 2012. All Rights Reserved. I IA AS S SUP FA 40