Glycol Dehydration Units Spec Sheet
Transcription
Glycol Dehydration Units Spec Sheet
MQC Glycol Dehydration Unit Value Through MQC Innovation More Efficient. Greater Flexibility. Higher Returns. Not all glycol dehydration units (GDU) are created equal. All remove unwanted water vapor from gas to prevent pipeline corrosion and line plugging (caused from hydrate formation), as well as reduce line capacity (caused from free water formation), but that’s where the similarities end. Ask us how the CDM Modular Quik-Connect (MQC) glycol dehydration unit design is superior to the competition. We Deliver What You Ask For! • • • • In-Stock Equipment Scalable Design Improved Project ROR 24/7 Service Availability • Ease of Doing Business Safety CDM is committed to safety. We are proud to Our stock MQC GDU size includes: 25 MMscfd Available in fleet on a limited basis include: A range of sizes between 1.5 MMscfd and 50 MMscfd CDM’s Modular Quik-Connect (MQC) design provides unparalleled value for producers by generating revenue sooner. Prefabricated in an ASME code shop, the CDM MQC design is complete with all piping, controls, instrumentation and electrical, and requires no concrete foundations. Reduced installation and demobilization time lessens total man hours per project thus decreasing total exposure to risk. This is why CDM has one of the best safety records in the industry. All CDM equipment is available for lease with full operation and maintenance service as well as bare rental, depending on customer needs. 20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com report our process & treating safety records. • Year-end TRIR of zero since company inception in 2008 • Zero recordable spills • Zero recordable injuries • Zero first aid injuries CDM’s Modular GDU design is Superior Innovation Our modular design allows for: • Consistency in installation • Quick response and rapid adjustments • Adaptable to changing conditions • Faster install and demobilization • Increased safety and easier operation MQC Glycol Dehydration Unit Pictured left: 50 MMscfd MQC GDU consists of: Front End Skid • Inlet Horizontal Coalescing Filter Separator • Contact Tower • Horizontal After Scrubber Back End Skid • Regeneration Unit BTEX Unit (optional; additional charge) At CDM, we believe time is money and safety is priceless. Glycol Solution 1200 Gallons Temporary Power (Generator) Glycol Make Up 500 gallon Regeneration Unit Skid Estimated Fuel Gas Consumption 30 MSCFD Power Requirement: N/A (fully pneumatic) N/A (fully pneumatic) 17,850 lb 20’-0” x 13’-3” x 12’-6” Glycol Contactor 33,500 lb 32’-0” x 7’-0” x 10’Skid 8” Glycol Contact Tower 29,172 lb 30’-0” x 4’-0” x 4’-0” *Note: All items above are CDM Resource Management LLC 20405 Tomball Parkway, Ste 700281.376.2980 www.CDMRM.com Houston, TX 77070 BTEX Unit BTEX Unit We Deliver What You Ask For! BTEX units are used to hold the toxic liquid elements (benzene, toluene, ethylbenzene, xylene) removed from natural gas. • • • • BTEX are usually paired with a Dehydrator and should be considered additions to the treating final solution. In-Stock Equipment Scalable Design Improved Project ROR 24/7 Service Availability • Ease of Doing Business Safety CDM is committed to safety. We are proud to report our process & treating safety records. • Year-end TRIR of zero since company inception in 2008 • Zero recordable spills • Zero recordable injuries • Zero first aid injuries Emissions Controls are Growing. The Clean Air Act limits the amounts of heavy hydrocarbons (a.k.a. Volatile Organic Compounds) which may be emitted from a facility to 250 tons per year. Aromatic compounds such as benzene are further classified as Hazardous Air Pollutants and are limited to 25 tons per year total aromatics and 10 tons per year of any individual aromatic. Eventually BTEX mandatory. 20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com units will become MQC T-Ox (Thermal Oxidizer) Value Through MQC Innovation More Efficient. Greater Flexibility. Higher Returns. Not all Thermal Oxidizers are created equal. Ours are a robust heavy duty system that enable 99.9% (DRE) destruction removal efficiency of unwanted chemicals in our Amine Plant Vent Gas. Ask us how the CDM Modular Quik-Connect (MQC) Thermal Oxidizer design is superior to the competition. We Deliver What You Ask For! • • • • In-Stock Equipment Scalable Design Improved Project ROR 24/7 Service Availability • Ease of Doing Business 1DAY INSTALL Safety CDM is committed to safety. We are proud to report our process & treating safety records. Our stock MQC Thermal Oxidzer sizes include: T-Ox 500 MSCFD (paired with our 100 GPM Amine plant) T-Ox 3000 MSCFD (paired with our 400 GPM Amine plant) CDM’s Modular Quik-Connect (MQC) design is skid mountd and provides unparalleled value for producers by generating revenue sooner. Prefabricated in an ASME code shop, the CDM MQC design is complete with all piping, controls, instrumentation and electrical, and requires no concrete foundations. Reduced installation and demobilization time lessens total man hours per project thus decreasing total exposure to risk. This is why CDM has one of the best safety records in the industry. All CDM equipment is available for lease with full operation and maintenance service as well as bare rental, depending on customer needs. 20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com • Year-end TRIR of zero since company inception in 2008 • Zero recordable spills • Zero recordable injuries • Zero first aid injuries What We Need To Know To Quote: • • • • Vent Gas Composition Vent Gas Flow Rate Temperature Pressure CDM’s Modular T-Ox design is Superior Innovation Our modular design allows for: • Consistency in installation • Quick response and rapid adjustments • Adaptable to changing conditions • Faster install and demobilization • Increased safety and easier operation MQC T-Ox (Thermal Oxidizer) MQC T-Ox consists of: • • • • • • • • • • Vertical Self Supported Stack Carbon Steel Firebox Flanged Sight Port UV Flame Scanner Port Flanged Waste Gas Inlet Thermocouple connections complete with thermocouples Special Alloy Rain Cap/Refractory Protector Pilot Burner Auxiliary Gas Burner Waste Gas Injector – Control/Ignition System – Pilot Monitoring Device At CDM, we believe time is money and safety is priceless. Weight Dimensions (foot print) MRW design QTI design 16,550 lb 30-0” x 8-0” x 7’-0” T-Ox T-Ox 3000 500 T-Ox 500 MRW design Weight Dimensions (foot print) Weight 13,500 lb 8-0” x 8’-0” x 310” 33,550 lb QTI design *Note: All items above are estimates CDM Resource Management LLC 20405 Tomball Parkway, Ste 700281.376.2980 www.CDMRM.com Houston, TX 77070 Natural Gas Driven Generator CDM’s Superior Innovation. We Deliver What You Ask For! Not all natural gas driven generators (NGD) are created equal. All offer our customers in remote areas a cheaper alternative to the diesel powered generators. • • • • More Efficient. Greater Flexibility. Higher Returns. Ask us how the CDM Natural Gas driven generator is superior to the competition. Our stock NGD Generator size includes: 350 KW (Est. weight: 35,000 lb; Est. Dimensions: 20’-4” x 8’-0”) CDM Resource Management LLC provide an electrical backup solution to power Amine Plants. Designed with speed to market advantage, all solutions are built for greater flexibility in the field to customize and adapt to the customer’s changing needs, including quicker demobilization and reduced cost. Reduced time and personnel on location also increases safety. This is why CDM has one of the best safety records in the industry. All CDM equipment is available for lease with full operation and maintenance service as well as bare rental, depending on customer needs. 20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com In-Stock Equipment Scalable Design Improved Project ROR 24/7 Service Availability • Ease of Doing Business Safety CDM is committed to safety. We are proud to report our process & treating safety records. • Year-end TRIR of zero since company inception in 2008 • Zero recordable spills • Zero recordable injuries • Zero first aid injuries Components Include: • • • • • Engine Driver Generator Control Panel Steel Enclosure Fuel Filter • Catalytic Converter/ Air Fuel Ratio Controller • Radiator and Fan