Glycol Dehydration Units Spec Sheet

Transcription

Glycol Dehydration Units Spec Sheet
MQC Glycol Dehydration Unit
Value Through MQC Innovation
More Efficient. Greater Flexibility. Higher Returns.
Not all glycol dehydration units (GDU) are created equal. All
remove unwanted water vapor from gas to prevent pipeline
corrosion and line plugging (caused from hydrate formation), as
well as reduce line capacity (caused from free water formation),
but that’s where the similarities end.
Ask us how the CDM Modular Quik-Connect (MQC) glycol
dehydration unit design is superior to the competition.
We Deliver What You Ask For!
•
•
•
•
In-Stock Equipment
Scalable Design
Improved Project ROR
24/7 Service Availability
• Ease of Doing Business
Safety
CDM is committed to safety. We are proud to
Our stock MQC GDU size includes:
25 MMscfd
Available in fleet on a limited basis include:
A range of sizes between 1.5 MMscfd and 50 MMscfd
CDM’s Modular Quik-Connect (MQC) design provides unparalleled
value for producers by generating revenue sooner. Prefabricated in
an ASME code shop, the CDM MQC design is complete with all
piping, controls, instrumentation and electrical, and requires no
concrete foundations. Reduced installation and demobilization time
lessens total man hours per project thus decreasing total exposure
to risk. This is why CDM has one of the best safety records in the
industry.
All CDM equipment is available for lease with full operation and
maintenance service as well as bare rental, depending on customer
needs.
20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com
report our process & treating safety records.
• Year-end TRIR of zero since company
inception in 2008
• Zero recordable spills
• Zero recordable injuries
• Zero first aid injuries
CDM’s Modular GDU design is
Superior Innovation
Our modular design allows for:
• Consistency in installation
• Quick response and rapid adjustments
• Adaptable to changing conditions
• Faster install and demobilization
• Increased safety and easier operation
MQC Glycol Dehydration Unit
Pictured left:
50 MMscfd
MQC GDU consists of:
Front End Skid
• Inlet Horizontal Coalescing Filter
Separator
• Contact Tower
• Horizontal After Scrubber
Back End Skid
• Regeneration Unit
BTEX Unit (optional; additional charge)
At CDM, we believe time is money and
safety is priceless.
Glycol Solution
1200 Gallons
Temporary Power
(Generator)
Glycol Make Up
500 gallon
Regeneration Unit
Skid
Estimated Fuel Gas
Consumption
30 MSCFD
Power Requirement:
N/A (fully pneumatic)
N/A (fully pneumatic)
17,850 lb 20’-0” x 13’-3” x
12’-6”
Glycol Contactor
33,500 lb 32’-0” x 7’-0” x 10’Skid
8”
Glycol Contact Tower 29,172 lb 30’-0” x 4’-0” x 4’-0”
*Note: All items above are
CDM Resource Management LLC
20405 Tomball Parkway, Ste 700281.376.2980
www.CDMRM.com
Houston, TX 77070
BTEX Unit
BTEX Unit
We Deliver What You Ask For!
BTEX units are used to hold the toxic liquid elements (benzene,
toluene, ethylbenzene, xylene) removed from natural gas.
•
•
•
•
BTEX are usually paired with a Dehydrator and should be
considered additions to the treating final solution.
In-Stock Equipment
Scalable Design
Improved Project ROR
24/7 Service Availability
• Ease of Doing Business
Safety
CDM is committed to safety. We are proud to
report our process & treating safety records.
• Year-end TRIR of zero since company
inception in 2008
• Zero recordable spills
• Zero recordable injuries
• Zero first aid injuries
Emissions Controls are Growing.
The Clean Air Act limits the amounts
of heavy hydrocarbons (a.k.a. Volatile
Organic Compounds) which may be
emitted from a facility to 250 tons per year.
Aromatic compounds such as benzene
are further classified as Hazardous Air
Pollutants and are limited to 25 tons per
year total aromatics and 10 tons per year
of any individual aromatic.
Eventually BTEX
mandatory.
20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com
units
will
become
MQC T-Ox (Thermal Oxidizer)
Value Through MQC Innovation
More Efficient. Greater Flexibility. Higher Returns.
Not all Thermal Oxidizers are created equal. Ours are a
robust heavy duty system that enable 99.9% (DRE) destruction
removal efficiency of unwanted chemicals in our Amine Plant
Vent Gas.
Ask us how the CDM Modular Quik-Connect (MQC) Thermal
Oxidizer design is superior to the competition.
We Deliver What You Ask For!
•
•
•
•
In-Stock Equipment
Scalable Design
Improved Project ROR
24/7 Service Availability
• Ease of Doing Business
1DAY
INSTALL
Safety
CDM is committed to safety. We are proud to
report our process & treating safety records.
Our stock MQC Thermal Oxidzer sizes include:
T-Ox 500 MSCFD (paired with our 100 GPM Amine plant)
T-Ox 3000 MSCFD (paired with our 400 GPM Amine plant)
CDM’s Modular Quik-Connect (MQC) design is skid mountd and
provides unparalleled value for producers by generating revenue
sooner. Prefabricated in an ASME code shop, the CDM MQC
design is complete with all piping, controls, instrumentation and
electrical, and requires no concrete foundations. Reduced installation
and demobilization time lessens total man hours per project thus
decreasing total exposure to risk. This is why CDM has one of the
best safety records in the industry.
All CDM equipment
is available for lease
with full operation
and
maintenance
service
as
well
as
bare
rental,
depending
on
customer needs.
20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com
• Year-end TRIR of zero since company
inception in 2008
• Zero recordable spills
• Zero recordable injuries
• Zero first aid injuries
What We Need To Know To Quote:
•
•
•
•
Vent Gas Composition
Vent Gas Flow Rate
Temperature
Pressure
CDM’s Modular T-Ox design is
Superior Innovation
Our modular design allows for:
• Consistency in installation
• Quick response and rapid adjustments
• Adaptable to changing conditions
• Faster install and demobilization
• Increased safety and easier operation
MQC T-Ox (Thermal Oxidizer)
MQC T-Ox consists of:
•
•
•
•
•
•
•
•
•
•
Vertical Self Supported Stack
Carbon Steel Firebox
Flanged Sight Port
UV Flame Scanner Port
Flanged Waste Gas Inlet
Thermocouple connections complete with thermocouples
Special Alloy Rain Cap/Refractory Protector
Pilot Burner
Auxiliary Gas Burner
Waste Gas Injector
– Control/Ignition System
– Pilot Monitoring Device
At CDM, we believe time is money and
safety is priceless.
Weight
Dimensions (foot
print)
MRW design
QTI design
16,550 lb
30-0” x 8-0” x
7’-0”
T-Ox T-Ox
3000 500
T-Ox
500
MRW design
Weight
Dimensions (foot
print)
Weight
13,500 lb
8-0” x 8’-0” x 310”
33,550 lb
QTI design
*Note: All items above are estimates
CDM Resource Management LLC
20405 Tomball Parkway, Ste 700281.376.2980
www.CDMRM.com
Houston, TX 77070
Natural Gas Driven Generator
CDM’s Superior Innovation.
We Deliver What You Ask For!
Not all natural gas driven generators (NGD) are created
equal. All offer our customers in remote areas a cheaper
alternative to the diesel powered generators.
•
•
•
•
More Efficient. Greater Flexibility. Higher Returns.
Ask us how the CDM Natural Gas driven generator is superior
to the competition.
Our stock NGD Generator size includes:
350 KW (Est. weight: 35,000 lb; Est. Dimensions: 20’-4” x 8’-0”)
CDM Resource Management LLC provide an electrical backup
solution to power Amine Plants. Designed with speed to market
advantage, all solutions are built for greater flexibility in the field to
customize and adapt to the customer’s changing needs, including
quicker demobilization and reduced cost. Reduced time and
personnel on location also increases safety. This is why CDM has
one of the best safety records in the industry.
All CDM equipment is available for lease with full operation and
maintenance service as well as bare rental, depending on customer
needs.
20405 Tomball Parkway, Ste 700 | Houston, TX 77070 | www.CDMRM.com
In-Stock Equipment
Scalable Design
Improved Project ROR
24/7 Service Availability
• Ease of Doing Business
Safety
CDM is committed to safety. We are proud to
report our process & treating safety records.
• Year-end TRIR of zero since company
inception in 2008
• Zero recordable spills
• Zero recordable injuries
• Zero first aid injuries
Components Include:
•
•
•
•
•
Engine Driver
Generator
Control Panel
Steel Enclosure
Fuel Filter
• Catalytic Converter/
Air Fuel Ratio
Controller
• Radiator and Fan