Bulletin A-180b - Brasch Manufacturing
Transcription
Bulletin A-180b - Brasch Manufacturing
Bulletin A-180b Contents Product Page Wall Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 2 Ceiling Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 4 Baseboard Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6 Cabinet Unit Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... 7 - 8 Washdown Unit Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 12 Hazardous Location Unit Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 - 18 Architectural Electric Convectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 - 22 BRASCH Architectural Forced Air WALL Heaters Decorator Designed for Functional Beauty and Versatility Rugged Grille: Heavy dark brown 18 gauge steel grille. Richly Styled Grille: Grille is highlighted by a 14-gauge anodized extruded aluminum frame. Electric Element: Steel sheath with plate heat exchanger. Fan Delay Switch: Allows fan to continue to run for a short period after thermostat is satisfied to expel warm air from inside heater, also delays fan on start up to insure delivery of heated air. Unique Vane Axial Fan Wheel draws in large volumes of air then quietly discharges heated air downward into room. Tamper Resistant Thermostat and Disconnect Switch accessible through grille. Specifications Model Number Watts Volts Weight BWH7512 750 120 22 lb. BWH1012 1000 120 22 lb. BWH1512 1500 120 26 lb. BWH4020 4000 208 29 lb. BWH4820 4800 208 29 lb. BWH1524 1500/1125 240/208 26 lb. BWH2024 2000/1500 240/208 27 lb. BWH3024 3000/2250 240/208 29 lb. BWH4024 4000/3000 240/208 29 lb. BWH4824 4800 240 29 lb. BWH1527 1500 277 26 lb. BWH2027 2000 277 27 lb. BWH3027 3000 277 29 lb. BWH4027 4000 277 29 lb. BWH4827 4800 277 29 lb. Field Installed Accessories Model Number Description Weight Box 3310 Rough-in Box Only (for advance installation) 10 lb. 3320EX33 Surface Mounting Adapter 1 lb. 3320EX16 2" Semi-recess Sleeve 1 lb. Factory Installed Accessories Suffix Description R Day Night Relay HD 16 Ga. Steel Heavy Duty Grill E L E C T R I C H E AT I N G P R O D U C T S Architectural Quality Wall Mounted ■ ■ ■ ■ ■ ■ ■ ■ Built-in disconnect switch Built-in tamper resistant thermostat Richly styled, rugged grille Whisper-quiet sound level Fan delay 1-Year element limited warranty U.L. listed CSA listed Typical Specifications Brasch Heavy-Duty Forced Air Heaters shall be constructed of a heavy 18 gauge steel housing with an extruded aluminum frame.The rough-in dimensions are 19-5/16" high x 14-3/16" wide x 4" deep.The units shall be available in ratings from 750 to 1500 watts at 120 and 1500 to 4800 watts at 240, 208 and 277 volts.The heaters shall have a low-speed 600 RPM, 4-pole motor which drives a vane axial blower to deliver a quiet 175 CFM of down flow air. The heating element shall be of the sealed tubular type with large, parallel steel fins for quick heat transfer. Unit shall have as standard, a thermal overload cutoff for added safety, fan delay switch and a builtin tamperproof thermostat which shall be calibrated to provide a range of 55°F. to 85°F. and manual disconnect switch. Optional accessories shall include a surface mounting adapter, day-night relays. All heaters shall be listed by Underwriter's Laboratories, Inc. The heating element shall be supplied with a manufacturer’s 1-year limited warranty. 1 Dimensions 2 B R A S C H M A N U FA C T U R I N G C O M PA N Y, I N C . BRASCH CEILING Heaters Recess • Surface • T-Bar Versatile application Large volume of comfortably warm air is produced by a whisper-quiet heater. Ideal for residential, commercial and industrial locations where wall and floor applications are not feasible. Quiet Operation Because of the extremely quiet operation, the BCH may be used in restaurants, nursing homes, schools and lobbies. They draw in large volumes of air and discharge heated air downward into the needed areas. These heaters feature the vane axial fan that has proven to be successful in other products. Specifications Model Number Watts Volts Weight BCH1512 1500 120 22 lb. BCH4020 4000 208 22 lb. BCH4820 4800 208 22 lb. BCH2024 2000/1500 240/208 22 lb. BCH3024 3000/2250 240/208 22 lb. BCH4024 4000/3000 240/208 22 lb. BCH4824 4800 240 22 lb. BCH2027 2000 277 22 lb. BCH3027 3000 277 22 lb. BCH4027 4000 277 22 lb. BCH4827 4800 277 22 lb. Field Installed Accessories Model Number Description Weight Box 3310 Rough-in Box Only (for advance installation) 10 lb. 3380 EX33 Surface Mounting Box 1 lb. TB 3380 T-Bar Mounting Box 7 lb. E L E C T R I C H E AT I N G P R O D U C T S Other Standard Features Include: ■ Neutral ceiling white, rust resistant finish to blend in with most any ceiling color or decor. Grille is shallow in design to look unobtrusive. ■ Automatic fan delay. When thermostat is satisfied, the fan continues to run momentarily until all heated air is discharged to insure efficiency. ■ Disconnect switch. ■ Totally enclosed steel fin sheath element for safety and long life. ■ Mounting Applications Recess (Standard) Surface (3380 EX33 Kit) 2x2 T-Bar (TB3380 Kit) Typical Specifications Brasch Electric Forced Air Heaters shall be constructed of a heavy gauge steel housing. The rough-in dimensions are 19-5/16" high x 14-3/16" wide x 4" deep. The finish shall be baked-on enamel paint in Ceiling White color. The units shall be available in ratings from 1500 through 4800 watts. The heaters shall have a low speed 600 RPM motor which drives a vane axial blower to deliver a quiet 175 CFM of down flow air. The heating element shall be of the sealed tubular type with large, parallel steel fins for quick heat transfer. Unit shall have as standard a thermal overload cutoff for added safety. All heaters shall be listed by Underwriters' Laboratories, Incorporated. The heating element shall be supplied with a manufacturer's 1 year limited warranty. 3 Dimensions 4 B R A S C H M A N U FA C T U R I N G C O M PA N Y, I N C . BRASCH BASEBOARD Heaters Specifications Model Number B24-375A B24-375B B24-375C B24-375D B28-500A B28-500B B28-500C B28-500D B36-600A B36-600B B36-600C B36-600D B40-750A B40-750B B40-750C B40-750D B48-1000A B48-1000B B48-1000C B48-1000D B48-750D B60-1250A B60-1250B B60-1250C B60-1250D B60-938D B72-1500A B72-1500B B72-1500C B72-1500D B72-1125D B84-1750B B84-1750C B84-1750D B84-1313D B96-2000B B96-2000C B96-2000D B96-1500D B120-2500B B120-2500C B120-2500D B120-1875D Volts 120 208 240/208 277/240 120 208 240/208 277/240 120 208 240/208 277/240 120 208 240/208 277/240 120 208 240/208 277/240 277 120 208 240/208 277/240 277 120 208 240/208 277/240 277 208 240/208 277/240 277 208 240/208 277/240 277 208 240/208 277/240 277 E L E C T R I C H E AT I N G P R O D U C T S Watts 375 375 375/281 375/281 500 500 500/375 500/375 600 600 600/450 600/450 750 750 750/563 750/563 1000 1000 1000/750 1000/750 750 1250 1250 1250/938 1250/938 938 1500 1500 1500/1125 1500/1125 1125 1750 1750/1313 1750/1313 1313 2000 2000/1500 2000/1500 1500 2500 2500/1875 2500/1875 1875 Heater Length 24" 24" 24" 24" 28" 28" 28" 28" 36" 36" 36" 36" 40" 40" 40" 40" 48" 48" 48" 48" 48" 60" 60" 60" 60" 60" 72" 72" 72" 72" 72" 84" 84" 84" 84" 96" 96" 96" 96" 120" 120" 120" 120" Stainless Steel Element Rod with Aluminum Fins ■ All heaters are constructed of roll formed steel and painted with a powder coat textured finish for outstanding durability and attractive appearance. Brasch Baseboards are available in both ivory and white - add suffix w to model number for white. ■ Quick connect cable clamps are located in right and left junction boxes to restrain incoming field wiring without the need for additional hardware. ■ All baseboards are only 6" high and extend 2 1/2" from the wall making the Brasch Baseboard heater one of the most compact baseboard heaters on the market. ■ All baseboards are constructed with a full length wireway along the back of the heater. An optional wireway cover can be ordered when specification calls for an enclosed wireway. ■ Integral thermostats use the junction box cover plate on the baseboard heater. This eliminates the need for stocking different colors of built-in thermostats. ■ A 6" ground lead wire is provided in both right and left junction boxes allowing for easier ground connection. ■ The Brasch Baseboard has long-lasting stainless steel element rod with its aluminum chimney designed fins. The fins are mechanically staked to the element rod to allow excellent transfer and dissipation of heat from the heater into the room. By using a stainless steel rod, the hum associated with other models on the market is eliminated. ■ An over-temperature thermal limit extends the entire length of the heated area to serve as a safety device in case of an air flow blockage in front of heater. ■ All units have 20 gauge junction boxes at both ends of the heater. The front and back of the heater are constructed of 22 gauge roll formed steel. ■ The heater can be mounted to the wall by using key hole knockouts every 4" at the back of the heater. 5 Dimensions Blank Sections Baseboard Ivory Length Model # Item Model Number Description Weight Disconnect Switch DS DSW Disconnect Switch-Ivory Disconnect Switch-White 1 lb. Corner Sections CS CSW Ivory Corner Section White Corner Section 1 lb. Joiner Kits JK JKW 1" Ivory Joiner Kit 1" White Joiner Kit 0.25 lb. 6" Blank Section (Relay Not Included) LVRS LVRSW 6" Ivory Relay Section 6" White Relay Section 1.5 lb. Receptacle Section (Baseboard Mounted) BDR115 BDR115W Ivory - 15amp, 120 VAC White - 15amp, 120 VAC 0.25 lb. Receptacle Section (Mtd. in 6" Blank Section) DR115 DR115W Ivory - 15amp, 120 VAC White - 15amp, 120 VAC 2 lb. Transfer Switch (Mtd. in 6" Blank Section) SR120 SR120W Ivory - 16amp, 120 VAC White - 16amp, 120 VAC 2 lb. Transfer Switch (Mtd. in 6" Blank Section) SR220 SR220W Ivory - 16amp, 240 VAC White - 16amp, 240 VAC 2 lb. Wireway Adapters (to enclose wireway when specified) 6 Model Number Baseboard Length Adapter Length Weight WWA01 WWA02 WWA03 WWA04 WWA05 WWA06 WWA07 WWA08 WWA09 WWA00 24" 28" 36" 40" 48" 60" 72" 84" 96" 120" 20" 24" 32" 36" 44" 56" 68" 80" 92" 116" 1 lb. 1.5 lb. 2 lb. 2.5 lb. 3 lb. 4 lb. 5 lb. 6 lb. 7 lb. 8 lb. White Model # 24" BBS024 BBS024W 28" BBS028 BBS028W 36" BBS036 BBS036W 40" BBS040 BBS040W 48" BBS048 BBS048W 60" BBS060 BBS060W 72" BBS072 BBS072W 84" BBS084 BBS084W 96" BBS096 BBS096W 120" BBS120 BBS120W Baseboard Accessories Model # TBS* Description SPST-In-built 22A/120-240V 18A/277V TBS-TP SPST-In-built 22A/120-240V 18A/277 V TAMPERPROOF TBD* DPST-In-built 22A/120-240V 18A/277V TBD-TP DPST-In-built 22A/120-240V 18A/277V TAMPERPROOF * Used on all baseboard models B R A S C H M A N U FA C T U R I N G C O M PA N Y, I N C . BRASCH Electrical CABINET UNIT Heaters The Brasch Cabinet Unit Heater (BCUH) is ideal for commercial and institutional applications such as offices, stores, schools, churches and entry ways. Standard units include a disconnect switch, built-in 24 volt thermostat and disposable air filters but the Brasch Cabinet Unit Heater can also be customized to meet your most demanding applications. All units have a beige powder coated finish over an 18 ga. steel housing that is 9 1⁄2" deep and 25" high and are manufactured with steel sheathed finned tubular elements with full-length thermal protection. Controls • Choice of eight control options include, built-in or wall mounted thermostats (24 or 120 volt) with built-in control transformer, as needed. • Independently adjustable heat settings (high / low) and fan motor speeds (1550 / 1400 rpm) are standard, except 480 volt units have a single fan speed. • Power interrupt options include either a circuit breaker or disconnect switch, except only circuit breakers can be used on heaters that draw over 48 amps. • Optional summer fan switch. Mounting & Flow Configurations • Mounting options include surface, semi-recessed or fully-recessed; on walls or ceilings; and upright or inverted. • Air flow can be configured in any combination of intake and output through the top, bottom or front. In addition, a duct collar can provide expanded application and flexibility. Air Flow Configurations (May be inverted) A Bottom In / Top Out (Top In / Bottom Out) B Bottom In / Front Out (Top In / Front Out) C Front In / Top Out (Front In / Bottom Out) D Standard Models Front In / Front Out * = Factory wired for 3 phase Field convertible to single phase Custom Models BRASCH WASHDOWN UNIT Heaters for Corrosion-Resistant Applications Mounting Bracket Easy-mount bracket for use with field-installed hanger or optional mounting brackets Scroll - 304 Stainless Steel Plated Inlet Grille Totally Enclosed Motor Stainless Steel Discharge Grille Aluminum Fan Blade Element Thermostat Three-Position Switch (Heat - Fan - Off ) Pilot Light (Heater Energized) Door Interlock Disconnection Switch (Optional) Rugged construction, stainless steel enclosure for use in wet* and corrosive* atmospheres (nonhazardous locations). *Refer to installation and application data for applicable environments or consult factory. E L E C T R I C H E AT I N G P R O D U C T S Nema 4x Non-Metallic Enclosure Control Components (24-volt Standard) The BWUH unit heaters are electric unit heaters constructed for use in areas that require washing or hosing of equipment due to dirty or dusty industrial environment in nonhazardous locations. the totallyenclosed watertight construction made with corrosion-resistant material make the BWUH Series ideal for industrial heating applications. The BWUH Series is made with all built-in controls and safety temperature controls wired in a non-metallic Nema 4x control panel with single-point power connections. 9 Standard Features: Options Sample Specification ■ Up to 48 KW ■ Teflon anodized aluminum fan blade (3-30 kw only) The electric unit heater shall be Brasch BWUH Series rated for washdown applications and shall include built-in controls. Heaters shall be UL Listed assemblies containing all limits and controls as required by UL specifications. Controls shall be housed in a Nema 4x non-metallic control enclosure fixed to bottom of unit heater. The control enclosure will open from bottom for ease of installation and service. The control enclosure will include contactors, 24-volt transformer, fusing (NEC required) pilot light (power on), thermostat and 3-position switch (heat - off - fan). ■ Up to 600 Volts ■ Disconnect switch with enclosure interlock ■ Heavy-duty 304 stainless steel shroud ■ Nema 4x non-metallic control panel ■ 24-volt transformer and control circuit ■ 3-position switch (off - heat - fan) ■ Capillary thermostat with stainless steel sensor ■ Automatic reset thermal cutout ■ Totally enclosed UL Listed motor ■ Pilot light (power on indicator) ■ Chrome-plated finned tubular element ■ Control panel on bottom of unit for ease in installation and service ■ Single-point power connection ■ Meets all UL, NEC, and OSHA requirements (when installed as directed) ■ Corrosion-resistant in high humidity and water-saturated areas (for areas where corrosion-resistance is needed in non-hazardous areas, contact factory for heater applications and optional materials). ■ Remote 24-volt thermostat ■ Stainless steel wall/ceiling mounting bracket (3.3-15 kw) ■ Cast iron painted mounting bracket available on all units for wall/ceiling or pipe mounting ■ Hanging bracket for use with threaded rod The heater scroll will be 16 gauge 304 stainless steel with 304 stainless steel outlet louvre. The inlet grille will be chrome plated. The motor shall be totally enclosed, permanently lubricated, designed to resist moisture and corrosion, and factory-wired to Nema 4x enclosure. Single point line voltage connection available for 208, 240, 277, 480, and 600 volt service. Door interlock disconnect on Nema 4x control enclosure shall be factory installed and wired. Heavy-duty heating elements factory wired and sealed for washdown application shall be plated for corrosion resistance. 10 B R A S C H M A N U FA C T U R I N G C O M PA N Y, I N C . Washdown Unit Heater Catalog Number KW BTU HR Heater Volts Phase Standard Control Voltage Max. Amps Motor Voltage HP RPM BWUH3.3-2081 BWUH3.3-2083 BWUH3.3-2401 BWUH3.3-2403 BWUH3.3-2771 BWUH3.3-4803 BWUH3.3-6003 3.3 3.3 3.3 3.3 3.3 3.3 3.3 11200 11200 11200 11200 11200 11200 11200 208 208 240 240 277 480 600 1 3 1 3 1 3 3 24 24 24 24 24 24 24 15.9 19.2 13.7 7.9 11.9 4.0 3.2 208 208 240 240 277 480 600 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1550 1550 1550 1550 1550 1550 1550 BWUH5.0-2081 BWUH5.0-2083 BWUH5.0-2401 BWUH5.0-2403 BWUH5.0-2771 BWUH5.0-4803 BWUH5.0-6003 5.0 5.0 5.0 5.0 5.0 5.0 5.0 17100 17100 17100 17100 17100 17100 17100 208 208 240 240 277 480 600 1 3 1 3 1 3 3 24 24 24 24 24 24 24 24.1 13.9 20.8 12.1 18.1 6.1 4.8 208 208 240 240 277 480 600 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1550 1550 1550 1550 1550 1550 1550 BWUH7.5-2081 BWUH7.5-2083 BWUH7.5-2401 BWUH7.5-2403 BWUH7.5-2771 BWUH7.5-4803 BWUH7.5-6003 7.5 7.5 7.5 7.5 7.5 7.5 7.5 25600 25600 25600 25600 25600 25600 25600 208 208 240 240 277 480 600 1 3 1 3 1 3 3 24 24 24 24 24 24 24 36.1 20.8 31.3 18.0 27.0 9.0 7.2 208 208 240 240 277 480 600 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1550 1550 1550 1550 1550 1550 1550 BWUH10-2081 BWUH10-2083 BWUH10-2041 BWUH10-2403 BWUH10-2771 BWUH10-4803 BWUH10-6003 10.0 10.0 10.0 10.0 10.0 10.0 10.0 34130 34130 34130 34130 34130 34130 34130 208 208 240 240 277 480 600 1 3 1 3 1 3 3 24 24 24 24 24 24 24 47.8 27.7 41.2 24.1 36.1 12.1 9.6 208 208 240 240 277 480 600 1/30 1/30 1/30 1/30 1/30 1/30 1/30 1550 1550 1550 1550 1550 1550 1550 BWUH15-2081 BWUH15-2083 BWUH15-2041 BWUH15-2403 BWUH15-4803 BWUH15-6003 15.0 15.0 15.0 15.0 15.0 15.0 51200 51200 51200 51200 51200 51200 208 208 240 240 480 600 1 3 1 3 3 3 24 24 24 24 24 24 72.1 41.7 62.5 36.1 18.1 14.5 208 208 240 240 480 600 1/30 1/30 1/30 1/30 1/30 1/30 1550 1550 1550 1550 1550 1550 BWUH20-2083 BWUH20-2403 BWUH20-4803 BWUH20-6003 20.0 20.0 20.0 20.0 68260 68260 68260 68260 208 240 480 600 3 3 3 3 24 24 24 24 55.6 48.2 24.1 19.3 208 240 480 600 1/3 1/3 1/3 1/3 1625 1625 1625 1625 BWUH25-2083 BWUH25-2403 BWUH25-4803 BWUH25-6003 25.0 25.0 25.0 25.0 85325 85325 85325 85325 208 240 480 600 3 3 3 3 24 24 24 24 69.5 60.2 30.1 24.1 208 240 480 600 1/3 1/3 1/3 1/3 1625 1625 1625 1625 BWUH30-2083 BWUH30-2403 BWUH30-4803 BWUH30-6003 30.0 30.0 30.0 30.0 102390 102390 102390 102390 208 240 480 600 3 3 3 3 24 24 24 24 83.9 72.3 36.1 28.9 208 240 480 600 1/3 1/3 1/3 1/3 1625 1625 1625 1625 BWUH40-4803 BWUH40-6003 40.0 40.0 136520 136520 480 600 3 3 24 24 46.2 38.5 480 600 1/3 1/3 1625 1625 BWUH48-4803 BWUH48-6003 48.0 48.0 163824 163824 480 600 3 3 24 24 57.8 46.2 480 600 1/3 1/3 1625 1625 E L E C T R I C H E AT I N G P R O D U C T S 11 CFM Outlet 400 400 400 700 700 1400 1400 1400 1800 1800 KW 3.3 5.0 7.5 10.0 15.0 20.0 25.0 30.0 40.0 48.0 H RPM Outlet 500 500 500 660 660 1000 1000 1000 1000 1000 A G F° Temp Rise Outlet 26 40 60 45 45 45 56 68 70 84 Air Throw Ft. 20 20 20 28 28 35 35 35 42 42 Mounting Bracket A5520 A5520 A5520 A5520 A5520 W5550 W5550 W5550 W5550 W5550 Weight 58 58 58 64 64 158 158 158 193 193 E Dimension Data C Heater Size 3-7.5 10-15 20-30 40-48 D B Figure 1 Rec. Mtg. Height/Ft. 6 6 6 6 6 6 6 6 6 6 Figure 2 Figure 3 A 12 14 16 18 B 18 19 27 31 C 19.75 21.75 28.75 30.75 D 15.25 15.25 19.50 19.50 E 16.25 18.00 17.50 19.50 F 6 ft. 6 ft. 6 ft. 6 ft. G 8.00 8.00 15.50 21.75 H 6.00 6.00 4.50 2.75 F COLUMN STABILIZING COMPONENTS MOUNTING BRACKET ATTACHMENT ASSY. Mounting Bracket Kits Ideal for use in buildings that have substantial walls. Arm (only) can be bolted directly to structure steel. Simple and economical if adequate overhead structure exists. Requires 1/2" pipe, cut and threaded (not supplied). WALL BRACKET ROOF OR OVERHEAD STRUCTURE MOUNTING ARM Particularly useful in buildings with insufficient strength to use other type of mounts. Requires 3 1/2" pipe (4" O.D. not supplied). 3 1/2" SCHEDULE 40 (PIPE) (NOT SUPPLIED) 1/2" PIPE (NOT SUPPLIED) BASE ASSEMBLY A5520 3.3-15 kw only WALL OR STRUCTURE WMK HMK PMK Optional - Wall Mounted Thermostat The T109 series of controls is intended for use in harsh environments. They tolerate continuous spraying with water, high humidity, airborne contaminates and moderately corrosive conditions. The nickel plated sensing bulb is attached directly to the bottom of the case where it is shielded from damage or accumulators of insulating particles. The molded Noryl case is sealed at the cover with a neoprene gasket and the adjusting knob opening is closed with a lubricated 0 ring. Underwriters Laboratories has tested the T109 and found it meets the requirement for NEMA 4x enclosures. 12 Raintight Industrial Thermostat High levels of accuracy and sensitivity are provided by the T109. Switching is done by heavy duty, precision, snap action switches. Setting is accomplished by rotating the adjusting knob. The dial face is printed with large contrasting numbers and letters on a lustrous background for good visibility. Force and motion for switch actuation are provided by changes in temperature expanding or contracting the fluid contained with the sensing bulb and transmitted hydraulically and through an appropriate linkage to the switch operator. Color coding clearly identifies the function of each conductor. Model Controls Switch Action TA109 Heating SPST TD109 Heating, 2pole 2 SPST Operation Opens circuit on temp rise Opens two switches on temp. rise The T109 is available with the following characteristics: Range 40 - 100°F Differential: 2.5°F Electrical Ratings: 120VAC 240VAC 277VAC Full Load 16.0A 12.0A 10.0A Locked Rotor 80.0A 60.0A 50.0A Non-inductive 24.0A 25.0A 22.0A Pilot Duty 125VA 125VA 125VA B R A S C H M A N U FA C T U R I N G C O M PA N Y, I N C . BRASCH HAZARDOUS LOCATION Heaters Explosion Proof Electric Heater Epoxy Coated 14 Ga. Cold Rolled Steel Cabinet Pressure Relief Valve Rated at 200 PSI Spiral Aluminum Finned Tubular Steel Heat Exchanger Core, Liquid Filled Operation 14 Ga. Steel Adjustable Louvers with Minimum Position Stops 24V Control Circuit Transformer Cast Aluminum Control Enclosure with Oversized Opening Heavy Duty Load Carrying Contactor Etched Aluminum Data Plates Riveted to Case Built-in Thermostat 45-90°F (optional) ■ Liquid to air heat exchanger with low watt density heating elements in ethylene glycol solution that provides freeze protection to -45°C. ■ Ball bearing permanently lubricated explosion proof motor. Chrome plated guard meets OSHA requirements. ■ Heavy-duty control contactor with 24 Volt control circuit provided on all models. E L E C T R I C H E AT I N G P R O D U C T S Copper Sheathed Immersion Type Heating Element CAUTION Before installing and operating heaters confirm location, classification and properties of flammable vapors, liquids, gases, dusts and fibers which may be present. Each room, section or area should be considered individually. For further information consult National Electric Code and National Fire Prevention Association (ANSI) standards. All models conform to OSHA requirements when mounted at any height. For Class I, Group D, Divisions 1 & 2 and Class II, Groups E, F and G, Divisions 1 & 2 13 BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain flammable gases, vapors, powdered metals or dusts. Abbreviated descriptions of UL classes, groups and divisions. Before selecting any heater for a particular application, refer to Article 500 as well as other standards referenced in the National Electric Code. ■ Permanently sealed, liquid to air, ■ Ethylene Glycol to water mixture Class I: Equipment does not have surface operating temperature in excess of the ignition temperature of the specific gas or vapor. ■ High-performance electric motor Class II: Equipment does not have surface temperature greater than the ignition temperature of the specified dust. finned tube heat exchanger core. used a heat transfer fluid in the heater core, providing -45°C, (-49°F) freeze damage protection. driven fan blows air across finned tubes to effect uniform heat transfer and area heat distribution. ■ Automatic Reset capillary type high limit provides high temperature regulation and is rated for 100,000 cycles of service. ■ Stainless steel and aluminum pressure relief valve for overpressure condition. ■ 14 Ga. steel cabinet epoxy paint finish contains heater core, motor and fan assembly. ■ Narrow gap safety fan guard shields all moving parts. ■ Adjustable louvers allow directional control of air. ■ Copper conductor wires enclosed in rigid metal conduits carry all electrical power. (Box lugs furnished for field connections within an approved enclosure) Group D: Atmospheres such as but not limited to acetone, alcohol, gasoline, lacquer solvent vapors, natural gas, propane or other gases or vapors of equivalent hazard. Group E: Atmospheres containing combustible metal dust regardless of resistivity, or other combustible dust of similar hazard characteristics having resistivity of less than 10° OHMCentimeter. Group F: Atmospheres containing carbon black, charcoal, coal or coke dust. Group G: Atmospheres containing combustible dust having resistivity of 10° OHM-Centimeter or greater. Division I: A location in which ignitable concentrations of flammable material exist under normal operating conditions. Division II: Locations in which flammable materials will normally be confined within closed containers and escape only in the case of accidental rupture, breakdown or during maintenance operations. Any equipment approved for Division I is automatically also approved for Division II. Built-in Hydraulic Thermostat optional on all BHUH models ■ Stainless steel bulb and capillary ■ 125 VA pilot duty ■ Used on 24 volt, 120 volt or 208-240 volt line voltage control ■ 60° to 90° temp range ■ Adjustable from front of unit with screwdriver. Hazardous Location Thermostat Wall Mounted Specifications ■ TW161 Single Pole ■ 22 Amps 125-277 Vac ■ 3/4 HP 125 Val ■ 1 1/2 HP 250-277 Vac ■ 5 1/2" H x 5 1/2" W x 4 3/4" D ■ Can be used for heating or cooling applications Installation Conditions 1. Refer to owner's manual. 2. The BHUH Series electric unit heaters have been listed by the Underwriters Laboratories for maximum surface temperatures. Use only in atmospheres having an ignition temperature higher than 165°C (T3B) for Class I operation and 165°C (T3B) for Class II. 3. Altitude restrictions - see specification table. 4. Heater must be installed in permanently mounted upright position and connected to fixed power supply. 5. Do not operate in atmospheres corrosive to steel and aluminum. 14 B R A S C H M A N U FA C T U R I N G C O M PA N Y, I N C . Specifications BHUH Model A UL Capacities Available UL Listing UL Temperature Code AIR CFM@70°F, (21°C) FPM Air Temp, Rise BHUH Model C 10KW 34,120 BTU 15KW 51, 180 BTU 20KW 68,240 BTU 25KW 85,300 BTU 580 1000 3KW 16.3°F* 5KW 27.2°F 7.5KW 40.8°F 24 ft. 8 ft. 7.5KW 5500 ft. 3* & 5KW 8000 ft. 10KW 8000 ft. Ambient Temp. Limits Min. -45°C, (-49°F) Max. 40°C, (104°F) RPM Propeller Fan 3 Wing, Alum. Motor 1725 1725 12" Dia. 16" Dia. Motor Voltage/Phase same as element. PSC, Explosion-Proof, Permanently Lubricated, Ball Bearing 1/4 HP 1/4 HP Horizontal Throw Max. Mtg. Height from floor Max. Operational Altitude MTR/BLADE 3KW 10,236 BTU* 5KW 17,060 7.5KW 25,590 BTU Class I, Group D, Divisions 1 & 2 Class II, Groups E, F & G, Divisions 1 & 2 Class I: T3B 165°C (329°F) Class II: T3B 165°C (329°F) BHUH Model B 1500 1600 10KW 21.0°F 40 ft. 10 ft. 2450 2000 15KW 19.0°F 20KW 25.5°F 25KW 32.3°F 43 ft. 13 ft. 25KW 5500 ft. 20KW 7000 ft. 15KW 8000 ft. 1725 20" Dia. 1/2 HP HEAT EXCHANGER Heat Exchanger Core Material Heat Transfer Fluid Heating Elements Heavy wall, liquid filled with immersion elements. Steel with aluminum fins. Ethylene-glycol solution, protected to -45°C (-49°F) Three, low watt density, immersion type copper sheathed. PROTECTION Thermal Cut-Out Relief Valve Snap action capillary type rated 100,000 cycles pilot duty. Stainless steel and aluminum construction, opens @ 200 PSI CABINET Cabinet Fan Guard Fasteners Conduit Material Control Box Hanger Connections 14 gauge cold rolled steel, epoxy coated, individually adjustable louvers. Wire, less than 1/4" spacing, plated, split design for easy removal Zinc plated. 3/4 rigid metal Cast aluminum with over-sized opening. (2) 1" NPS with conduits stops for field wiring. 5/8" NC tap, 2 holes. CONTROLS Contactors Heavy duty, break all ungrounded conductors rated 100,000 cycles @ full load. Built-in and pre-wired. Built-in and pre-wired - 24 volt secondary (standard) 120 volt (optional) 24 volt standard on all models 120 volt optional on all models (not available on 600V models) Line voltage on 208 and 240 volt models only Explosion proof 40° - 90°F operating range 22A 125-277VAC - 3/4HP @ 125VAC; 1 1/2 HP @ 250-277VAC 125 VA pilot duty Sensing Bulb and Capillary made from 300 Series Stainless Steel ASW Tube 132 lbs. 3 & 5KW 158 lbs. 10KW 190 lbs. 15 & 20KW 167 lbs. 7.5KW 225 lbs. 25KW Control Transformer Control Circuits Remote wall mounted Thermostat Model TW161 Built-in "T" Option Heater Net Weight Shipping Weight E L E C T R I C H E AT I N G P R O D U C T S 15 Mounting Bracket Kits Roof or Overhead Structure 1/2" Pipe (Not Supplied) Column Stabilizing Components Mounting Arm Assy. Attachment Assy. BHHM Hanging Mounting Kit Simple and economical if adequate overhead structure exists. Requires 1/2" pipe, cut and threaded (no supplied). 3 1/2" Schedule 40 (Pipe), (Not Supplied) Attachment Assembly 3 to 7.5KW Models 10KW Models 15 to 25KW Models HANGING KITS BHHM All Models WALL MOUNTING KITS BHWM 75 3 to 7.5KW Models BHWM 10 10KW Models BHWM 25 15 to 25KW Models Wall Bracket Base Assembly PIPE KITS BHPM 75 BHPM 10 BHPM 25 Mounting Arm Sample Specifications BHPM Pipe Mounting Kit Particularly useful in buildings with insufficient strength to use other type of mounts. Requires 3 1/2" pipe (4" O.D. - not supplied). Wall or Structure BHWM Wall Mounting Kit Ideal for use in buildings that have substantial walls. Arm only can also be bolted directly to structural steel. Physical Dimensions Inches Model A B 3Ø BHUH-A 17 3/4 22 3/8 BHUH-B 20 3/4 BHUH-C 24 3/4 C 1Ø D E F G 19 3/4 20 5/8 16 1/4 10 1/2 14 3 26 3/8 20 3/4 21 5/8 20 1/4 11 1/2 18 4 30 3/8 22 1/2 — 24 1/4 12 1/2 22 4 1/2 Contactors shall supply and install Brasch type BHUH explosion-proof suspended fan-forced unit heaters of the capacity and voltage listed on the plans. Heaters shall be UL listed for Class I, Group D, Divisions 1 & 2 and Class II, Groups E, F and G, Divisions 1 & 2, UL temperature code shall be T3B (165°C) for Class 1, and T3B (165°C) for Class II, indicating maximum operating surface temperatures. Heat exchangers shall be heavy walled, liquid filled, with three, low watt density, immersion type copper sheathed elements hermetically sealed into the core along with the high limit thermal cut-out. Heat transfer fluid shall be ethylene-glycol solution, protected to -45°C (-49°F). Motors shall be PSC, explosion-proof, permanently lubricated, ball bearing type, 1725 rpm. Contactors shall be built-in and pre-wired into an explosion-proof enclosure. Contactors shall be heavy duty and break all ungrounded conductors and be rated for 100,000 cycles at full load. Control transformers shall be built-in and pre-wired. Control circuits shall be 24 volt. Cabinet shall be 14 gauge cold rolled steel, epoxy coated plated fan guard shall have less than 1/4 inch spacing to conform with OSHA requirements. All fasteners shall be zinc plated. Heater conduits shall be cadmium plated seamless steel or aluminum. Mounting Kits Brasch offers three mounting kits available for the Series: the BHPM Pipe Mounting Kit; the BHHM Hanging Mounting Kit; and the BHWM Wall Mounting Kit. Each of these is illustrated and described in this brochure.To order, specify the type of kit with the heater model desired. Consult our Sales Department for details. 16 B R A S C H M A N U FA C T U R I N G C O M PA N Y, I N C . Performance Data Model Volts Phase KW Heater Amps Line Amps BTU/HR BHUH 3-2081 BHUH 3-2083 BHUH 3-2401 BHUH 3-2403 BHUH 3-4803 BHUH 3-6003 208 208 240 240 480 600 1 3 1 3 3 3 3.0 3.0 3.0 3.0 3.0 3.0 14.4 8.3 12.5 7.2 3.6 2.9 16.3 9.8 14.8 8.6 4.3 3.5 10250 10250 10250 10250 10250 10250 16.6 16.6 16.6 16.6 16.6 16.6 BHUH 5-2081 BHUH 5-2083 BHUH 5-2401 BHUH 5-2403 BHUH 5-4803 BHUH 5-6003 208 208 240 240 480 600 1 3 1 3 3 3 5.0 5.0 5.0 5.0 5.0 5.0 24.0 13.9 20.8 12.0 6.0 4.8 26.0 15.4 23.1 13.4 6.7 5.4 17100 17100 17100 17100 17100 17100 BHUH 7.5-2081 BHUH 7.5-2083 BHUH 7.5-2401 BHUH 7.5-2403 BHUH 7.5-4803 BHUH 7.5-6003 208 208 240 240 480 600 1 3 1 3 3 3 7.5 7.5 7.5 7.5 7.5 7.5 36.1 20.8 31.3 18.0 9.0 7.2 38.0 22.3 33.6 19.4 9.7 7.8 BHUH 10 BHUH 10-2083 BHUH 10-2401 BHUH 10-2403 BHUH 10-4803 BHUH 10-6003 208 240 240 480 600 3 1 3 3 3 10.0 10.0 10.0 10.0 10.0 27.8 41.7 24.1 12.0 9.6 BHUH 25 BHUH 15-2083 BHUH 15-2403 BHUH 15-4803 BHUH 15-6003 208 240 480 300 3 3 3 3 15.0 15.0 15.0 15.0 BHUH 20-4803 BHUH 20-6003 480 600 3 3 BHUH 25-4803 BHUH 25-6003 480 600 3 3 Size BHUH 7.5 Air Temp Min Cir Rise Deg F Ampacity Max Fuse Amps Min. Wire AWG?* 20.4 12.3 18.5 10.8 5.4 4.4 25 15 20 15 15 15 10 14 12 14 14 14 27.6 27.6 27.6 27.6 27.6 27.6 32.4 19.2 28.9 16.8 8.4 6.8 35 20 30 20 15 15 8 12 10 12 14 14 25600 25600 25600 25600 25600 25600 41.4 41.4 41.4 41.4 41.4 41.4 47.5 27.9 42.0 24.3 12.2 9.8 50 30 45 25 15 15 8 10 8 10 14 14 29.3 44.0 25.5 12.7 10.2 34150 34150 34150 24150 34150 21.7 21.7 21.7 21.7 21.7 36.6 55.0 31.8 15.9 12.8 40 60 35 20 15 8 6 8 12 14 41.6 36.1 18.0 14.4 43.5 38.1 19.0 15.2 51200 51200 51200 51200 19.2 19.2 19.2 19.2 54.4 47.6 23.8 19.0 60 50 25 20 6 8 10 12 20.0 20.0 24.1 19.2 25.1 20.0 68300 68300 26.2 26.2 31.3 25.1 35 30 8 10 25.0 25.0 30.1 24.1 31.1 24.9 85400 85400 32.8 32.8 38.8 31.1 40 35 8 8 *Supply conductors must be suitable for 90°C Controls Thermostats ■ Standard unit includes 24 volt ■ Add suffix "T" to model # for built-in ■ 120 volt option — delete 24 suffix ■ Remote thermostat — see wall transformer and contactors on model # — add 120 to model # thermostat thermostat specifications on page 16 ■ 600 volt models available with 24 volt controls only E L E C T R I C H E AT I N G P R O D U C T S 17 18 B R A S C H M A N U FA C T U R I N G C O M PA N Y, I N C . Fusing Not Required on 24V Class II Transformer 3 Phase Heater with 120 Volt Control Shown: BRASCH ARCHITECTURAL ELECTRIC CONVECTORS Architectural Convectors are custom built with unsurpassed craftsmanship. Standard length and custom fitted draft barrier, sill height and pedestal heaters meet the most demanding architectural specifications. Low initial cost and negligible maintenance make them suitable for all projects stressing energy and cost optimization. ■ Front cover enclosures are available Application ■ Aluminum sheath element has Brasch Architectural Convectors are ideal for perimeter heating of schools, lobby areas, public buildings, nursing homes and other commercial applications providing individual room control and warm air draft protection for wall and window exposures. Heating capabilities to 750 watts per foot in a wide variety of cabinet styles provide continuous clean horizontal lines to complement any building project. Enclosures are available in standard and special painted colors and in clear and color anodized finishes. in continuous lengths up to maximums (see Table 1) to eliminate unnecessary splices (special order). Aluminum only. ■ Full length thermal cutout with automatic reset prevents overheating when airflow is blocked. Heating elements mounted on free floating nylon bushings for quiet operation. mechanically bonded fins for cooler operating temperatures. ■ Built-in 1/2 inch EMT raceway allows field wiring from either end. (3/4 inch EMT also available). ■ Control section can accommodate optional controls as required. ■ Junction boxes in heaters (except DBTS) will accept most controls (see page 23). ■ Optional controls include thermostat, disconnect (with or without 20 amp fuse and fuse block), power relay, transformer relay and PE switch. ■ Accessories (see page 23) include end caps, wall trim splice plates, inside and outside corners, mullion fronts, inside fillers, blank sections, control sections, 1/4 inch wire mesh under grille, pedestals and duplex receptacles. ■ Disconnect switch and relay, separately or in combination with thermostat, allow for right hand wire entry. Integral thermostat allows wire entry at either end. Finishes The standard finish on all heaters is ASI Bronze paint. Other standardized paint colors which are available are Eggshell White, Beige, Gray, and Black. Anodized finishes can be provided on aluminum enclosure heaters. Those available are 204R1 Clear, 313R1 Bronze and Black. Actual samples of any of the foregoing finishes can be provided upon request. Additionally, special painted colors can be provided to match submitted color samples. Heater backs (except RDBTPD) are not finished unless specified. Construction Features ■ Snap-fit construction saves installation time, eliminates unsightly screws. Snap-fit Construction Back Cover ■ Pencil-proof louvers have 1/4 inch spacings. 1/4" Pencil-proof Louvers ■ Heavy gauge extruded aluminum grilles with 15 degree angled louvers direct heated air away from wall for cleaner operation. Junction Box Features Built-in Thermostat And Disconnect if Required ■ Enclosures are fabricated of heavy gauge materials to assure compliance with architectural requirements to withstand years of rough usage. All enclosures can be finished to match window mullions, wall surfaces and interior decor. High Efficiency Bonded Aluminum Fins Assure Cool Surface Temperatures ■ Multiple heaters factory wired on the same backplate are available up to maximum front enclosure lengths (see Table 1). E L E C T R I C H E AT I N G P R O D U C T S Full Length Thermal Overload Protection Aluminum Front Cover 19 Standard Profile Draft Barriers DBF & DBT Dual Element Draft Barriers DBCF & DBCT Rounded Pedestal Draft Barriers RDBT-PD These heaters have a 6" x 3 1/2" profile with a snap-fit extruded aluminum enclosure and a 12 ga. aluminum backplate. The DBF is available with up to 250 watts per foot of heating and the DBT with up to 300 watts per foot of heating. DBF is designed for floor mounting with front inlet and top outlet. DBT is designed for wall mounting with bottom inlet and top outlet but pedestals can be supplied for floor mounting. These heaters have a 7" x 5" profile with a snap-fit extruded aluminum enclosure and a 10 ga. aluminum backplate. The DBCF is available with up to 650 watts per foot of heating and the DBCT with up to 750 watts per foot of heating. DBCF is designed for floor mounting with front inlet and top outlet. DBCT is designed for wall mounting with bottom inlet and top outlet but pedestals can be supplied for floor mounting. The RDBT-PD heater has a rounded 6" x 7" profile with a flat bottom and a flat top and has an extruded aluminum enclosure.The heater is supported on 1 3/4" - 2 1/4" adjustable pedestals.The RDBT-PD is available with up to 300 watts per foot of heating.The heater is designed for floor mounting with bottom inlet and top outlet. Low Profile Draft Barriers DBTS & CB Sill Height Draft Barriers ASHDB The DBTS heater has a 4" x 2 5/8" profile and the CB heater has a 4 1/2" x 2 5/8" profile. Both have a snap-fit extruded aluminum enclosure and a 14 ga. aluminum backplate.The DBTS heater is available with up to 300 watts per foot of heating.The CB heater is available with up to 250 watts per foot of heating. Both are designed for wall mounting with bottom inlet and top outlet but pedestals can be supplied for floor mounting. Standard Elements The following standard elements are available in even foot lengths at the watts per foot heat outputs shown for single phase voltages: 277 240 208 120 ________________________________ 125 94 93 125 165 124 106 188 188 141 113 250 200 150 141 250 188 188 333 250 212 375 282 250 DBCF, DBCT and ASHDB can be furnished with any combination of two elements. Special elements at different heat outputs and/or lengths are available. The ASHDB has a standard 5 1/2" depth and heights are available from 8" to 20" in 1/16" increments—specify height required. The front cover is 16 ga. steel and the backplate is 18 ga. steel. The grille is extruded aluminum. The ASHDB is available with up to 500 watts per foot of heating. The heater is designed for wall mounting with bottom inlet and top outlet. Pedestals can be supplied for floor mounting of 8" height only. Table 1: Model Comparisons Type Enclosure Dimension (H x D) DBF Standard 6" x 3 1/2" Front Inlet Top Outlet 250 .100" Extruded Aluminum/15 Ft. Extruded Aluminum Floor Painted Bronze Color or Clear Anodized Std. and Spcl. Painted Colors DBT Standard 6" x 3 1/2" Bottom Inlet Top Outlet 300 .100" Extruded Aluminum/15 Ft. Extruded Aluminum Wall Painted Bronze Color or Clear Anodized Std. and Spcl. Painted Colors DBTS Low Profile 4" x 2 5/8" Bottom Inlet Top Outlet 300 .070" Extruded Aluminum/15 Ft. Extruded Aluminum Wall Painted Bronze Color or Clear Anodized Std. and Spcl. Painted Colors CB Low Profile 4 1/2" x 2 5/8" Bottom Inlet Top Outlet 250 .070" Extruded Aluminum/15 Ft. Extruded Aluminum Wall Painted Bronze Color or Clear Anodized Std. and Spcl. Painted Colors Model Airflow Maximum Heat Watts/Ft Front Enclosure/ Max Length Finishes Grilles Mounting Standard Optional DBCF Dual Element 7" x 5" Front Outlet Top Outlet 650 .100" Extruded Aluminum/12 Ft. Extruded Aluminum Floor Painted Bronze Color or Clear Anodized Std. and Spcl. Painted Colors DBCT Dual Element 7" x 5" Bottom Outlet Top Outlet 750 .100" Extruded Aluminum/12Ft. Extruded Aluminum Wall Painted Bronze Color or Clear Anodized Std. and Spcl. Painted Colors ASHDB Sill Height 8" - 20" X 5 1/2" Bottom Inlet Top Outlet 500 16 ga. Steel/ 10 Ft. Extruded Aluminum Wall Painted Bronze Std. and Spcl. Painted Colors RDBT-PD Rounded 6" x 7" Bottom Inlet Top Outlet 300 .100" Extruded Aluminum/12 Ft. Extruded Aluminum Floor Painted Bronze Color or Clear Anodized Std. and Spcl. Painted Colors 20 B R A S C H M A N U FA C T U R I N G C O M PA N Y, I N C . Accessories Controls IC OC EC CS ITS Inside Corner Outside Corner End Cap—left or right (N/A RDBT-PD) IEC Inside Fitting End Cap— left or right (N/A DBTS, CB, DBCF, AHSDB) WT Wall Trim SP Splice Plate, 1 1/2" - 6" (N/A RDBT-PD) MF Mullion Front to 1 foot (DBF, DBT, CB only) IF Inside Filler to 1 foot (DBF, DBT, DBCT only) BS Blank Section—specify length (1'-0" to 10'-0") ASB Conduit 3/4" Raceway (1/2" Standard) ASB Mesh 1/4" wire mesh under grille ASB DR Duplex Convenience Receptacles ASB PD Pedestals—specify 2" or 3" (3" over 300W/Ft) ITD IDS IDSF PR TR PE Control Section—6" or 12" Single Pole Thermostat— 20 amps Double Pole Thermostat— 20 amps Double Pole Disconnect— 20 amps Double Pole Disconnect w/20 amp fuse and fuse block Power Relay—18 amps Transformer Relay Pressure Electric Switch DBTS requires a CS with any controls. A six inch CS will accept 1 or 2 controls, a twelve inch CS will accept 3 controls. CB will accept only a thermostat, disconnect or power relay in the junction box. More or other controls require a CS. All other heaters will accept any two of the following controls to be installed in the junction box— disconnect and thermostat, disconnect and power relay or disconnect and PE switch. Increase the length of the heater enclosure by 6" or 12" when using a control section. Integral thermostats are mounted on the left side unless otherwise specified; integral disconnects are mounted on the right side unless otherwise specified; integral relays are mounted on the left side unless otherwise specified. Heaters are wired for either right or left hand entry where there are no controls. Otherwise, entry is in the junction box containing the controls. How to Order Example: Model Number DBF-2200-277-ASI Bronze-ITS Model Length (in feet) When Ordering, specify: ■ Model Number Watts per foot Voltage ■ Length (in feet) ■ Watts Per Foot Finish Color ■ Voltage Built-in Controls ■ Finish Color ■ Built-in Controls E L E C T R I C H E AT I N G P R O D U C T S 21 Sample Specification Electric convectors shall be architectural series by Brasch Manufacturing Co., Inc. as scheduled: Series Description Height By Depth DBF—Draft Barrier (front inlet) 6" x 3 1/2" DBT—Draft barrier (bottom inlet) 6" x 3 1/2" DBTS—Draft barrier (bottom inlet) 4" x 2 5/8" CB—Draft barrier (bottom inlet) 4 1/2" x 2 5/8" DBCF—Draft barrier (front inlet) 7" x 5" DBCT—Draft barrier (bottom inlet) 7" x 5" ASHDB—Sill Height (bottom inlet) 8" - 20" x 5 1/2" RDBT-PD Rounded Pedestal (bottom inlet) Draft barrier shall be fabricated of aluminum extrusions with 1/4" pencilproof louvers at a 15" angle for improved convection and cleaner operation. Cabinets to have clean square corners, suitable for front or bottom intake and heating at watts per foot as scheduled. Sill height convectors shall be fabricated of 16 gauge furniture steel with 14 gauge extruded aluminum, pencil-proof louvers installed at a 15° angle for improved convection and cleaner operation. Enclosure covers, louvers and end caps will snap-fit together without screws or fasteners for easy maintenance. Wallmounted units shall have pre-punched slots for quick installation. Pedestal and 22 6" x 7" mullion-to-mullion units to have solid finished backs without slots. Standard backed acrylic bronze or optional painted or anodized finish will be provided in architectural colors as scheduled. Provide full length linear thermal cutout with automatic reset on all units to prevent overheating from blocked airflow. Provide built-in EMT raceway with factory wiring and 3/4" knockouts on side and rear of junction boxes at each end. Heater to accept field wiring at either end when optional controls are not included. Blank sections shall be fully enclosed for branch circuit wiring. Heating elements shall be aluminum sheath with mechanically bonded fins to maximize heat transfer and limit fin temperatures to 330°F. Elements shall be centered in freefloating nylon bushings for quiet operation. Per schedule, controls include single or double pole thermostats, disconnect switches, and relays. Thermostats shall be adjustable (tamperproof ) through discharge louver. Separate control sections shall include factory mounted PE switches, mercury contactors, circuit breakers and control transformers (as scheduled). Accessories shall include end caps, wall trim, splice plates, inside and outside corners, and blank sections of matching material for visual continuity. All heaters and controls shall be listed by Underwriters Laboratories, Inc. and warranted for one year from date of sale. B R A S C H M A N U FA C T U R I N G C O M PA N Y, I N C . Limited Warranty All Brasch Manufacturing Company, Inc. products covered in this bulletin are warranted against defects in workmanship and materials for one year from date of purchase. This warranty does not apply to damage from accident, misuse or alteration; nor where the connected voltage is more than 5% above product nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of installation instructions. This warranty is valid only in the fifty states of the United States. No other written or oral warranty applies. No employee, agent, dealer or other person is authorized to extend warranty on behalf of Brasch Manufacturing Company. The customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs. Inoperative units should be returned to Brasch, attention of Service Manager for repair or replacement at our option. Product will be returned freight prepaid. Repair or replacement is the exclusive remedy available from Brasch who is not liable for damages of any kind, including incidental and consequential damage. 2310 Millpark Drive M a r y l a n d H e i g h t s , MO 63043 314.291.0440 - Fax 314.291.0646 e-mail: [email protected] www.braschmfg.com ©Brasch Manufacturing Company, Inc.