Construction Details1
Wood Moulding2
Louver Unites - Wood and Metal 4
Vision Panels - Wood and Metal
5
Factory Installed Glass6
Astragals/Edges9
Dutch Door10-15
Door with Transoms16-21
Wicket Door22
Special machining - Rabbiets/Radius Edge
23
Fire Door Plant-Ons24
Full Glass / Full Warranty Door
26
ElectroLynx27
1
Construction Details
Technical Manual
October, 2013
Meeting Edge Options
General Moulding Requirements
Species shall match or be compatible
with face veneer or laminate
No Bevel
Bevel
Flat Astragal
Specify transparent or opaque finish.
Moulding shall be free of open defects,
shake, splits, or doze
Rabbeted
Parallel Bevel
Dbl. Egress
Metal Edge
Guards/Astragal
Metal Edge
Guards
Moulding must be smooth and free of
visibale knife, saw or sanding marks
Specify from the options on the left:
Glazing Options
Graham Standard Minimums
Flush Mouldings
All cutouts for metal or wood vision
panels must be a minimum of 5” (152
mm) from the edge of the door and/or
other cutouts for louvers, locks, closers
or other hardware.
This 5” (152 mm) distance must be
maintained or the fire label and warranty will be voided. For non-fire rated
doors, the distance may be decreased
to 5” (127 mm). Less than 5” (127 mm)
may affect the warranty
Metal Vision
Frame
Lip
Moulding
Using a 10” (254 mm) margin between
the edge of the door and the edge of any
cutout near the lock area will eliminate
most label and warranty conflicts.
2
Wood Mouldings
Technical Manual
June, 2011
Lip Moulding for Lites
3
2
1
1. Matching specie to door face veneer for Premium grade. For use with 1-3/4” thick
doors
M2G - Flat Lip Moulding 15/16” wide x 5/8” thick, 3/32” radius.
M3G - Beveled Lip Moulding 15/16” wide x 3/8” thick, 3/32” radius
2. Wire Brad - Lip Moulding is factory attached.
3. 1/4” Glazing - Glazing materials are not included.
4. Beveled back for glazing compound or 1/16” tape (not included).
5. Lites - Order size - visible glass size
Cutout size = visible glass + (2 x moulding profile)
Glass size = cutout - 1/4” wide - 1/4” high
4
15/16”
15/16”
3/32”
3/32”
3/8”
3/8”
5/8”
11/16”
5/8”
11/16”
M2G
M3G
Flush Moulding for Lites
3
2
1. Matching specie to door face veneer for Premium grade. For use with 1-3/4” thick
doors
M6G - Flush Moulding 11/16” wide x 3/8” thick, 3/32” radius.
2. Wire Brad - Flush Moulding is factory attached.
3. 1/4” Glazing - Glazing materials are not included.
4. Beveled back for glazing compound or 1/16” tape (not included).
5. Lites - Order size - visible glass size
Cutout size = visible glass + (2 x moulding profile)
Glass size = cutout - 1/4” wide - 1/4” high
1
4
3/32”
3/8”
11/16”
M6G
3
Wood Mouldings
Technical Manual
August, 2011
Fire Rated Flush Wood Moulding for Lites
1.
2.
3.
4.
Available with 45, 60 and 90 minute fire rated (mineral core) doors.
Factory installed: glass, glazing material, glazing bead, clips, nails, provided.
Flush Moulding Profile: MF3
Available Species: Red Oak, Natural Birch, White Maple, Cherry, Mahogany, and
Walnut. Contact you Customer Service Professional for availability of other
species.
5. Glass: 1/4” thick nominal wired glass or 3/16” thick nominal ceramic
6. Cutout Size and Glass Size: (100 in2 maximum)
Cutout Width = Visible Glass Width + 1.500”
Cutout Height = Visible Glass Height + 1.500”
Glass Width = Visible Glass Width + 1.375”
Glass Height = Visible Glass Height + 1.375”
3/4”
MF3
4
Louver Units
Technical Manual
June, 2011
V-Slat Wood Louver
1
1. L100 Wood Non-Vision Louver Unit - 3/4” wide, 33% free air movement. Matching
specie to door face veneer for Premium grade. For use with 1-3/4” thick doors.
Specify louver size the same as cutout size. 1-3/8” thick doors require framed
louvers. Louvers may not be installed in 20 minute fire doors.
M2W - Flat Lip Moulding 11/16” wide x 5/8” thick, 3/32” radius.
M6W - Flush Moulding 7/16” wide x 3/8” thick, 3/32” radius
2. Wire Brad - Mouldings are factory attached. Louvers are not factory installed as
standard. Louvers may be facorty installed as an option.
3. Field installation may require the use of glazing tape for proper fit.
1/2”
3
3/4”
2
11/16”
3/32”
3/32”
3/8”
5/8”
7/16”
7/16”
M2W
M6 W
V-Slat Metal Louver
1
1/2”
3
1. L600 Metal Non-Vision Louver Unit - 1-1/16” wide, 20 gauge steel, 50% free air
movement. For use with 1-3/4” thick doors. 1-3/8” thick doors require framed
louvers. Louver cutout is 1/8” less then order size. Louvers may not be installed in
20 minute fire doors.
M2M - Flat Lip Moulding 9/16” wide x 5/8” thick, 3/32” radius.
M6M - Flush Moulding 5/16” wide x 3/8” thick, 3/32” radius
2. Wire Brad - Mouldings are factory attached. Louvers are not factory installed.
Louvers may be facorty installed as an option.
3. Field installation may require the use of glazing tape for proper fit.
1/16”
2
9/16”
3/32”
3/32”
3/8”
5/8”
5/16”
M2M
5/16”
M6M
Metal Fusible Link Louver
3
1
2
1. L1900A Framed Metal Non-Vision Louver Unit - Fire rated fusible link unit for use
with 45, 60 or 90 minute fire doors. 1-3/4” wide. 135 degree F fusible link. 40% free
air movement. For use with 1-3/4” thick doors only. Not factory installed. Louvers
may not be installed in 20 minute fire doors.
2. Stell mounting frame overlaps door face 1”.
3. Through bolt applied. Security screws are available by option.
4. Metal fusible link louvers will not be factory installed.
5
Vision Panels
Technical Manual
June, 2011
Fire rated Metal Vision Panel
1. M110 Metal Vision Frame - Fire rated for 20, 45, 60 and 90 minute fire door
applications. 18 gauge steel with mitered, round corners that are braced and
welded. Available wood veneer wrapped as an option. Low profile for hardware
clearance.
2. Metal frame and glazing support clip.
3. Vandal proof binder screw.
4. For 1/4” thick listed glazing (not included).
Note: No glazing compound or tape is required. Not factory installed.
5. Fire rated metal vision panels will be factory installed.
6. Lites - Order size = visible glass size
Cutout size = visible glass size + 1-1/2” side + 1-1/2” high
Glass size = visible glass size + 3/4” wide + 3/4” high
7. Listed for UL10b and UL10c.
4
3
1
2
Note: Custom shapes for specialty lites must be specified for visible glass size and cutout size.
4
1
3
2
4
20 Minute Moulding for Lites
1. Matching specie to door face veneer for Premium grade. For use with 1-3/4” thick
20 minute rated fire doors.
M2L - Beveled Lip Moulding 1” wide x 3/4” thick.
M2F - Beveled Flush Moulding 3/4” wide x 1/2” thick.
2. Metal glazing support clip.
3. Glazing compound or tape required for proper fit (not included).
4. For 1/4” thick listed glazing (not included).
Size are visible glass size. Cutouts are 1” larger in width and height.
Custom shapes for specialty lites must be specified for visible glass size and cutout size.
5. Lites - Order size = visible glass size
Cutout size = visible glass size + (2 x moulding profile)
Glass size = cutout - 1/4” wide - 1/4” high
6. Listed for UL10b and UL10c.
Note: Custom shapes for specialty lites must be specified for visible glass size and cutout size.
11/16”
1/2”
1/2”
1/2”
9/32”
1
1”
3
2
M2F
M2L
6
Factory Installed Glass
Technical Manual
April, 2013
PYRAN® PLATINUM F (FIG03)
Glass Description
CERAMIC, FILMED FIRE AND SAFETY RATED GLASS
BRAND: PYRAN PLATINUM F
GRADE: PREMIUM
THICKNESS: 3/16” NOMINAL
WARRANTY: 3 YEAR LIMITED
INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED
IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II
FIRE LISTINGS
UL AND
INTERTEK/WARNOCKHERSEY APPROVED,
POSITIVE PRESSURE.
GLASS IS MARKED IN
ACCORDANCE WITH
INTERNATIONAL
BUILDING CODE
SECTION 715.4.6 AND
2406
RATING
MAXIMUM
EXPOSED AREA
MAXIMUM
WIDTH
MAXIMUM
HEIGHT
CORE TYPE
20, 45
1296
36
54
Mineral, Particleboard, Stave Lumber,
Engineered Composite, Agrifiber
1
20, 45
2550
34
75
Mineral, Particleboard, Stave Lumber,
Engineered Composite
2
60*
900
12
75
Mineral
2
60*
864
24
36
Mineral
60, 90
1296
24
54
Mineral
Temp Rise
100
12
33
Mineral
NOTES
2
* 2 lites max
1 Same as above PEMKO FG3000845
2 Same as above PEMKO FG3000890
PYRAN® PLATINUM L (FIG04)
Glass Description
CERAMIC, LAMINATED FIRE AND SAFETY RATED GLASS
BRAND: PYRAN PLATINUM L
GRADE: PREMIUM
THICKNESS: 3/8” NOMINAL
WARRANTY: 5 YEAR LIMITED
INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED
IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II
FIRE LISTINGS
UL AND
INTERTEK/WARNOCKHERSEY APPROVED,
POSITIVE PRESSURE.
GLASS IS MARKED IN
ACCORDANCE WITH
INTERNATIONAL
BUILDING CODE
SECTION 715.4.6 AND
2406
RATING
MAXIMUM
EXPOSED AREA
MAXIMUM
WIDTH
MAXIMUM
HEIGHT
CORE TYPE
20, 45
1296
36
54
Mineral, Particleboard, Stave Lumber,
Engineered Composite, Agrifiber
1
20, 45
2550
34
75
Mineral, Particleboard, Stave Lumber,
Engineered Composite
2
60*
900
12
75
Mineral
2
60*
864
24
36
Mineral
2
60, 90
1296
24
54
Mineral
Temp Rise
100
12
33
Mineral
NOTES
* 2 lites max
1 Same as above PEMKO FG3000845
2 Same as above PEMKO FG3000890
7
Factory Installed Glass
Technical Manual
April, 2013
FIRELITE® NT (FIG05)
Glass Description
CERAMIC, FILMED FIRE AND SAFETY RATED GLASS
BRAND: FIRELITE NT
GRADE: PREMIUM
THICKNESS: 3/16” NOMINAL
WARRANTY: 3 YEAR LIMITED
INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED
IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II
FIRE LISTINGS
UL APPROVED, POSITIVE
PRESSURE. GLASS IS
MARKED IN
ACCORDANCE WITH
INTERNATIONAL
BUILDING CODE
SECTION 715.4.6 AND
2406
RATING
MAXIMUM
EXPOSED AREA
MAXIMUM
WIDTH
MAXIMUM
HEIGHT
CORE TYPE
20, 45
1296
36
54
Mineral, Particleboard, Stave Lumber,
Engineered Composite, Agrifiber
1
20, 45
2856
34
84
Mineral, Particleboard, Stave Lumber,
Engineered Composite
2
60*
960
12
80
Mineral
2
60*
864
24
36
Mineral
2
60, 90
1296
24
54
Mineral
Temp Rise
100
12
33
Mineral
NOTES
* 2 lites max
1 Same as above PEMKO FG3000845
2 Same as above PEMKO FG3000890
FIRELITE® PLUS (FIG06)
Glass Description
CERAMIC, LAMINATED FIRE AND SAFETY RATED GLASS
BRAND: FIRELITE PLUS
GRADE: PREMIUM
THICKNESS: 5/16” NOMINAL
WARRANTY: 5 YEAR LIMITED
INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED
IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II
FIRE LISTINGS
UL APPROVED, POSITIVE
PRESSURE. GLASS IS
MARKED IN
ACCORDANCE WITH
INTERNATIONAL
BUILDING CODE
SECTION 715.4.6 AND
2406
RATING
MAXIMUM
EXPOSED AREA
MAXIMUM
WIDTH
MAXIMUM
HEIGHT
CORE TYPE
20, 45
1296
36
54
Mineral, Particleboard, Stave Lumber,
Engineered Composite, Agrifiber
1
20, 45
2856
34
84
Mineral, Particleboard, Stave Lumber,
Engineered Composite
2
60*
960
12
80
Mineral
NOTES
2
60*
864
24
36
Mineral
2
60, 90
1296
24
54
Mineral
Temp Rise
100
12
33
Mineral
* 2 lites max
1 Same as above PEMKO FG3000845
2 Same as above PEMKO FG3000890
8
Factory Installed Glass
Technical Manual
December, 2010
1/4” TEMPERED (FIG01)
Glass Description
1/4” CLEAR TEMPERED IMPACT SAFETY RATED GLASS
QUALITY RATING: Q3, ASTM C1036-06
THICKNESS: 1/4” NOMINAL
WARRANTY: 1 YEAR LIMITED
INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED
IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II
GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION 2406
NOT FOR USE ON FIRE RATED DOORS
1/4” FILMED WIRE (FIG02)
Glass Description
1/4” FILM WIRE, FIRE AND IMPACT SAFETY RATED GLASS
QUALITY RATING: Q3, ASTM C1036-06
THICKNESS: 1/4” NOMINAL
WARRANTY: 1 YEAR LIMITED
INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED
IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II
FIRE LISTINGS
UL AND
INTERTEK/WARNOCKHERSEY APPROVED,
POSITIVE PRESSURE.
GLASS IS MARKED IN
ACCORDANCE WITH
INTERNATIONAL
BUILDING CODE
SECTION 715.4.6 AND
2406
RATING
MAXIMUM
EXPOSED AREA
MAXIMUM
WIDTH
MAXIMUM
HEIGHT
CORE TYPE
20, 45
1296
36
54
Mineral, Particleboard, Stave Lumber,
Engineered Composite, Agrifiber
60, 90 *
300
15
33
Mineral
100
12
33
Mineral
Temp Rise
* Non Temp Rise
9
Astragals/Edges
Technical Manual
June, 2011
Flat Wood Astragal
1. A1 Wood Astragal - 2” wide, 1/2” thick, 1/4” radius on face edges. Matching specie
to door face veneer for Premium grade. For use with 1-3/4” or 1-3/8” thick doors.
2. May be applied using wood screws and adhesive.
3. Not for use on any 45, 60 or 90 minute fire rated doors. Flat wood astragals may
be applied to 20 minute neutral pressure tested pairs with Firestop metting edges.
1
Metal Astragal & Edge
3
1. M207. metal Edge Set With Overlapping Astragal - 16 gauge welded astragal
overlaps meeting edge 1”. Approved for 20, 45, 60 and 90 minute fire door
applications. Available wood veneer wrapped as an option. May be specified
unmachined or machined for builders hardware.
2. 20 gauge wrap-around metal edge overpals meeting stile 1”.
3. Phillips Flat head Screws - #8 x 3/4” 12” on center (included).
Note: Overlapping astragals are no longer required for fire rated pairs.
1
2
Double Metal Edge
2
1
1. M208 Double Metal Edge Set - 20 gauge wrap-around metal edge overlaps
metting stiles of doors 1”. Approved for 20, 45, 60 and 90 minute fire door
applications. Available wood veneer wrapped as an option. may be specified
unmachined or machined for builders hardware.
2. Phillips Flat head Screws - #8 x 3/4”, 12” on center (included).
Note: Double metal edges are no longer required on 20, 45, 60 or 90 minute paris
if doors are specified to be without metal edges. Requires special interior blocking
profiles.
3. Also available with 5” wrap-around metal edges for use with the application of
concealed vertical rod exit devices in the M250 series.
10
Dutch Door (Non Fire Rated)
Technical Manual
June, 2011
General Notes
Allow for shelf thickness when specifying hardware.
Standard shelf is 1.125” (28 mm) thick wood, 1 side only.
Standard wood shelf sits between leaves.
Shelf and supports are not factory installed
Note if shelf is not required.
Note if other than standard shelf is required.
Dutch doors are available in GPD or GCD bonded consturction
only.
8. GPD has matching bottom rail in top leaf. GCD has non-matching
bottom rail in top leaf.
9. Dutch doors are available in single openings up to 4’0” x 8’0”.
Dutch doors are available in paired openings up to 8’0” x 8’0”.
Height By Specification
1.
2.
3.
4.
5.
6.
7.
1-3/4”
(includes shelf)
Height By Specification
1/8”
8”
Shelf
4”
1-1/8”
4”
Shelf Bracket
11
Dutch Door (Non Fire Rated)
Technical Manual
June, 2011
NON RATED DUTCH DOOR
TOP LEAF
2” Wood Rails (Min.)
1-1/8” Wood Shelf
2” Wood Rails (Min.)
General Notes
1. Dutch doors may be provided with:
a. Straight cut metting edges of top and bottom leaf.
b. Rabbeted metting edges of top and bottom leaf.
2. Standard clearnace between top leaf and bottom
leaf of Dutch doors is 3/16”.
3. Dutch door latching may be cylindrical, mortise
or flushbolt latches that latch:
a. top leaf into bottom leaf, bottom leaf into frame.
b. top leaf into bottom leaf, top leaf into frame.
c. top leaf into frame, bottom leaf into frame.
BOTTOM LEAF
EXAMPLE OF LATCHING CONFIGURATION
TOP LEAF
TOP LEAF
BOTTOM LEAF
BOTTOM LEAF
ACTIVE LEAF
INACTIVE LEAF
PAIR OF DUTCH DOORS
12
Dutch Door (20 Minute Fire Rated)
Technical Manual
June, 2011
General Notes
Height By Specification
1.
2.
3.
4.
5.
6.
7.
(includes shelf)
Height By Specification
1/8”
Allow for shelf thickness when specifying hardware.
Standard shelf is 1.125” (28 mm) thick wood, 1 side only.
Standard wood shelf sits between leaves.
Shelf and supports are not factory installed
Note if shelf is not required.
Note if other than standard shelf is required.
Dutch doors are available in GPD or GCD bonded consturction
only.
8. GPD has Firestop bottom rail in top leaf. Firestop top rail in
bottom leaf. GCD has Firestop bottom rail in top leaf, Firestop
top rail in bottom leaf.
9. Dutch doors are not available in 90 minute neutral pressure
tested construction.
10. Positive pressure fire tested Dutch door constructions are not
available.
11. Dutch doors are available in 20 minute fire rated single openings
up to 4’0” x 8’0”.
12. Dutch doors are available in 20 minute fire rated paired openings
up to 8’0” x 8’0”.
1-3/4”
8”
Shelf
1-1/8”
4”
4”
Shelf Bracket
13
Dutch Door (20 Minute Fire Rated)
Technical Manual
June, 2011
20 MINUTE DUTCH DOOR
TOP LEAF
2” wide Firestop Rails (Min.)
Intumescent
1-1/8” Wood Shelf
2” wide Firestop Rails (Min.)
BOTTOM LEAF
General Notes
1. 20 minute Dutch doors may be provided with
one of these:
a. An overlapping astragal applied to the bottom rail of the top leaf
b. Intumescent fire seal installed in the bottom rail of the top leaf.
c. Standard wood shelf sits between leaves.
2. A maximum 1/8” (3.2 mm) clearance between
top leaf and bottom leaf of fire rated Dutch doors
is allowed.
3. Fire rated Dutch doors require both leaves to be
self latching. Leaf to leaf or leaf to frame.
4. Fire rated Dutch door latching is limited to
cylindrical or mortise latches that latch:
a. top leaf into bottom leaf, bottom leaf into frame.
b. top leaf into bottom leaf, top leaf into frame.
c. top leaf into frame, bottom leaf into frame.
5. Flushbolts are allowed on the inactive leaves of a
pair.
EXAMPLE OF LATCHING CONFIGURATION
TOP LEAF
TOP LEAF
BOTTOM LEAF
BOTTOM LEAF
ACTIVE LEAF
INACTIVE LEAF
PAIR OF DUTCH DOORS
14
Dutch Door (45/60 Minute Fire Rated)
Technical Manual
June, 2011
General Notes
Height By Specification
1.
2.
3.
4.
5.
6.
7.
(includes shelf)
Height By Specification
1/8”
Allow for shelf thickness when specifying hardware.
Standard shelf is 1.125” (28 mm) thick wood, 1 side only.
Standard wood shelf butts to face of bottom leaf.
Shelf and supports are not factory installed
Note if shelf is not required.
Note if other than standard shelf is required.
Dutch doors are available in GPD or GCD bonded consturction
only.
8. GPD has Firestop bottom rail in top leaf. Firestop top rail in
bottom leaf. GCD has Firestop bottom rail in top leaf, Firestop
top rail in bottom leaf.
9. Dutch doors are not available in 90 minute neutral pressure
tested construction.
10. Positive pressure fire tested Dutch door constructions are not
available.
11. Dutch doors are available in 45/60 minute fire rated single
openings up to 4’0” x 8’0”.
12. Dutch doors are not available in 45/60 minute fire rated paired
openings.
1-3/4”
8”
Shelf
1-1/8”
4”
4”
Shelf Bracket
15
Dutch Door (45/60 Minute Fire Rated)
Technical Manual
June, 2011
45/60 MINUTE DUTCH DOOR
TOP LEAF
2” wide Firestop Rails (Min.)
Intumescent
1-1/8” Wood Shelf
2” wide Firestop Rails (Min.)
BOTTOM LEAF
EXAMPLE OF LATCHING CONFIGURATION
TOP LEAF
TOP LEAF
BOTTOM LEAF
BOTTOM LEAF
General Notes
1. 45/60 minute Dutch doors may be provided with
one of these:
a. An overlapping astragal applied to the bottom rail of the top leaf
b. Intumescent fire seal installed in the bottom rail of the top leaf.
c. Standard wood shelf sits between leaves.
2. A maximum 1/8” (3.2 mm) clearance between
top leaf and bottom leaf of fire rated Dutch doors
is allowed.
3. Fire rated Dutch doors require both leaves to be
self latching. Leaf to leaf or leaf to frame.
4. Fire rated Dutch door latching is limited to
cylindrical or mortise latches that latch:
a. top leaf into bottom leaf, bottom leaf into frame.
b. top leaf into bottom leaf, top leaf into frame.
c. top leaf into frame, bottom leaf into frame.
16
Door with Transoms (Non Fire Rated)
Technical Manual
June, 2011
Non-rated Doors with Transoms
1. Doors with transoms are available with or without frame transom bars in
single or paired openings.
2. Meeting edges of transoms and doors in openings without transom bars may
be straight cut or rabbeted. See standard rabbet detail.
3. Doors with transoms are available in GPD and GCD bonded constructions
only.
4. GPD has matching rails at bottom of transom and top of door. GCD has nonmatching rails at bottom of transom and top of door.
5. Spring bolts are required for installation of transom panels. Springbolts must
be placed a minimum of 2” (51 mm) from each corner.
Panels up to 18” (458 mm) in height require 2 springbolts per side.
Panels up to 36” (916 mm) in height require 3 springbolts per side.
Panels up to 40” (1220 mm) in height require 4 springbolts per side.
6. Doors with transoms are available in single openings up to 4’0” x 10”0”.
Maximum transom panel size in a single opening up to 4’0” wide x 3’4” high.
Doors with transoms are available in paired openings up to 8’0” x 10’0”.
Maximum transom panel size is a paired opening is 8’0” wide x 3’4” high.
17
Doors with Tramsoms (Non-Rated)
Technical Manual
June, 2011
NON RATED DOOR WITH TRANSOM
Solid Wood Cores
Transom
2” Wood Rails
1/8” Max. Gap
1/8” Max. Gap
2” Wood Rails
Steel Astragals
Solid Wood Cores
1-3/4”
1-3/4”
DOOR WITH TRANSOM
IN FRAME WITH MULLION
Non-Rated Doors with Transoms
Transom
2” Wood Rails
Mullion
2” Wood Rails
1. Doors with transom may be provided with:
a. Straight cut meeting edges of door and transom with an over lapping astragal.
b. Straight cut meeting edges of door and transom with frame transom bar.
c. Rabbeted meeting edges of door and transom.
2. A maximum 1/8” (3.2 mm) clearance between
door and transom is allowed in non-rabbeted
applications.
3. Transom panels must be installed using
springbolts placed a minimum of 2” (51 mm)
from each corner.
18
Door with Transoms (20 Minute Fire Rated)
Technical Manual
June, 2011
20 Minute Fire Rated Doors with Transoms
1. Transom panels must be the same construction as the 20 minute fire door.
2. Neutral pressure tested doors with transom panels may be rabbeted, or installed with a metal edge
and astragal, or with a transom bar between the door and transom.
Positive pressure tested doors with transom panels must be installed in a frame with a transom bar between the door and transom.
3. Transom installed over a pair of 20 minute rated doors must be separated with a frame mullion. The
mullion must limit the width of each separate transom to the width of each leaf of the door pair.
4. The transom panel must be machined for spring bolts by the licensed machiner of manufacturer. The
appropriate number of springbolts will be supplied by the machiner.
5. Fire rating labels will be provided on door and transom stating “Door and Transom Assembly.”
6. Fire rated transom panels must be installed using approved steel springbolts. The springbolts shall be
placed 2” (51 mm) from each corner with the minimum number centered on each side. Holes must
be drilled in the frame to accept the springbolts. Hole locations vary with respect to rabbeted and
unrabbeted tansoms.
Panels up to 18” (458 mm) in height require 2 springbolts per side.
Panels up to 36” (916 mm) in height require 3 springbolts per side.
Panels up to 40” (1220 mm) in height require 4 springbolts per side.
7. Maximum clearance between the frame and panel must be 1/8” (3.2 mm).
8. Doors with transoms are available in single openings up to 4’0” x 10”0”. Maximum transom panel size
in a single opening up to 4’0” wide x 3’4” high. Doors with transoms are available in paired openings
up to 8’0” x 10’0”. Maximum transom panel size is a paired opening is 8’0” wide x 3’4” high. Transom
panels above pairs of doors must be separated by a mullion.
19
Doors with Tramsoms (20 Minute Fire Rated)
Technical Manual
June, 2011
20 MINUTE DOOR WITH TRANSOM
Solid Wood Cores
Transom
1” Wide Firestop Rails Min.
1/8” Max. Gap
1/8” Max. Gap
1” Wide Firestop Rails Min.
Steel Astragals
Solid Wood Cores
1-3/4”
1-3/4”
20 MINUTE DOOR WITH TRANSOM
IN FRAME WITH MULLION
Transom
1” Wide Firestop
Rails Min.
Mullion
1” Wide Firestop
Rails Min.
20 Minute Doors with Transoms
1.
Neutral pressure tested fire doors with transoms may be
provided with:
a. Straight cut meeting edges of door and transom with an over lapping astragal.
b. Straight cut metting edges of door and transom with frame transom bar.
c. Rabbeted meeting edges of door and transom.
Positive pressure tesed fire doors with transoms must be installed in a frame with
transom bar between the door and transom.
2. A maximum 1/8” (3.2 mm) clearance between door
and transom is allowed in non-rabbeted applications.
Maximum clearance between the frame and transom
panel must be 1/8” (3.2 mm).
3. Fire rated Transom panels must be installed using
approved steel springbolts. The springbolts shall be
placed 2” (51 mm) from each corner with the minimum
number centered on each side. Holes must be drilled in
the frame to accept the springbolts. Hole locations vary
with respect to rabbeted and unrabbeted transoms.
Panels up to 18” (458 mm) in height require 2 springbolts per side.
Panels up to 36” (916 mm) in height require 3 springbolts per side.
Panels up to 40” (1220 mm) in height require 4 springbolts per side.
20
Door with Transoms (20 Minute Fire Rated)
Technical Manual
June, 2011
45/60/90 Minute Fire Rated Doors with Transoms
1. Transom panels must be the same construction as the 20 minute fire door.
2. Neutral pressure tested doors with transom panels may be rabbeted, or installed with a metal edge and astragal, or
with a transom bar between the door and transom. Rabbeted door and transom assemblies must be constructed with
minimum 5” (127 mm) Firestop bottom rail of transom and top rail of door. The rabbet must be a minimum 1/2” (13 mm)
deep x 7/8” (22 mm) wide.
Positive pressure tested doors with transom panels must be installed in a frame with a transom bar between the door and
transom.
3. If an overhead door closer is to be installed the bottom rail of the transom and the top rail of the door must be 5” (127
mm) Firestop. When transom bar is provided the rails shall be standard Firestop or Firestop II material.
4. Transom installed over a pair of fire rated doors must be separated with a frame mullion. The mullion must limit the width
of each separate transom to the width of each leaf of the door pair.
5. The transom panel must be machined for spring bolts by the licensed machiner of manufacturer. The appropriate number
of springbolts will be supplied by the machiner.
6. Fire rating labels will be provided on door and transom stating “Door and Transom Assembly.”
7. Fire rated transom panels must be installed using approved steel springbolts. The springbolts shall be placed 2” (51 mm)
from each corner with the minimum number centered on each side. Holes must be drilled in the frame to accept the
springbolts.
Panels up to 18” (458 mm) in height require 2 springbolts per side.
Panels up to 36” (916 mm) in height require 3 springbolts per side.
Panels up to 40” (1220 mm) in height require 4 springbolts per side.
Maximum clearance between the frame and panel must be 1/8” (3.2 mm).
8. Neutral pressure tested fire doors with transoms are available in single openings up to 4’0” x 10”0”.
Positive pressure tested fire doors with transoms are available in single openings up to 4’0” x 9”0”.
Neutral pressure tested fire doors with transoms are available in paired openings up to 8’0” x 10”0”.
Positive pressure tested fire doors with transoms are available in paired openings up to 8’0” x 9”0”.
Maximum transom panel size in a single opening up to 4’0” wide x 3’4” high.
Maximum transom panel size in a paired opening is 4’0” wide x 3’4” high.
Transom panels above pairs of doors must be separated by a mullion.
21
Doors with Tramsoms (45/60/90 Minute Fire Rated)
Technical Manual
June, 2011
45/60/90 MINUTE DOOR WITH TRANSOM
Transom
5” Wide Firestop Rails Min.
1/8” Max. Gap
1/8” Max. Gap
5” Wide Firestop Rails Min.
Steel Astragals
1-3/4”
1-3/4”
45/60/90 MINUTE DOOR WITH TRANSOM
IN FRAME WITH MULLION
45/60/90 Minute Doors
with Transoms
1.
Neutral pressure tested fire doors with transoms may be
provided with:
a. Straight cut meeting edges of door and transom Transom
with an over lapping astragal.
b. Straight cut metting edges of door and transom with frame transom bar.
G-P Firestop Composition c. Rabbeted meeting edges of door and transom. 1” Wide Firestop
Rabbeted meeting edges require 5” (127 mm)
Rails Min.
bottom rail of tramson and top rail of door.
Positive pressure tesed fire doors with transoms must be installed in a frame with transom bar
between the door and transom.
2. A maximum 1/8” (3.2 mm) clearance between door
Mullion
and transom is allowed in non-rabbeted applications.
Maximum clearance between the frame and transom
panel must be 1/8” (3.2 mm).
3. Fire rated Transom panels must be installed using
approved steel springbolts. The springbolts shall be
placed 2” (51 mm) from each corner with the minimum
G-P Firestop Composition
number centered on each side. Holes must be drilled in
the frame to accept the springbolts. Hole locations vary
1” Wide Firestop
with respect to rabbeted and unrabbeted transoms.
Rails Min.
Panels up to 18” (458 mm) in height require 2 springbolts per side.
Panels up to 36” (916 mm) in height require 3 springbolts per side.
Panels up to 40” (1220 mm) in height require 4 springbolts per side.
22
Wicket Doors (Standard)
Technical Manual
June, 2011
General Notes
1.
2.
3.
4.
Requires handing of call door and wicket door.
Latch/lock for call door must be suitable for rabbeted application
Shelf and call door are not factory installed
Available in GPD or GCD bonded constructions only.
Hinged Side
Unrabbeted
Rabbeted
Call
Door
3/32”
Reveal
Shelf
1-1/8” Thick Shelf
Wicket
Door
1-3/4”
8”
2”
Shelf
13/16”
4”
Opening Size
Call Door Size
9/16”
1-3/4”
Typical Rabbet
4”
Shelf Bracket
23
Special Machining
Technical Manual
June, 2011
Standard Rabbet
General Notes
1. Provide non-vision joint between door and transom.
2. Non-fire rated wood core door/transom units hae solid matching
hardwood top rail in door and bottom rail in transom.
3. Rabbets allow 1/8” spacing between door and transom when door is in
closed position.
4. Available on 20-minute rated doors/transoms.
5. May be applied to 45, 60 and 90-minute fire doors. Mineral core
fire door/transom units do not have matching rails. requires special
construction.
6. Available on 1-3/4” thick doors only.
7. Available in GPD or GCD bonded constructions only.
Note: GPD has matching bottom rail on top leaf and matching top rail on bottom leaf.
GCD has non-matching bottom rail on top leaf and non-matching top rail on bottom leaf.
Transom
General Notes
Door
Radius Edge
1. Used on doors when specified using pivot hinges or when double
acting door is specified.
2. When specified for application to lock stile, verify lock/latch hardware
compatibility. Requires full face stile.
3. When specified for application to hinge stile, verify radius of edge with
hardware template requirements.
4. Available on 1-3/4” thick doors only.
5. Available in GPD or GCD bonded constructions only.
6. Not available on any fire rated door.
7. Specify radius on hinge and lock edge.
Available Radii (R)
Convex
Concave
2-1/2”
1-7/8”
1-1/2”
1-5/32”
1-5/32”
24
Fire Door Plant-ons
Technical Manual
June, 2011
General Notes
Decorative Door Plant-ons are allowed on 20, 45, 60 and 90 minute
labeled fire doors. The following conditions apply:
1. Type, size and configuration are limited by the door
manufacturer’s tested authorities.
2. The plant-ons must be applied under label service at factory or
qulaified distributor. Plant-ons may not be field applied to fire
rated doors.
Minimum spacing
to edge of door or
cutout.
Profiles offered by Graham:
Minimum spacing
between plant-ons.
1. Graham offers the following profiles. Customers may supply
assembled plant-ons in other species and profiles, provided they
meet the specifications for the intended use listed below. These
may also be used on non-fire rated doors.
9/16”
3/4”
1-1/2”
1-1/2”
P-7
P-8
Minimum enclosed
area.
Twice the profile
width for width of
area..
5/8”
2-3/8”
P-9
Specifications
20 Minute
GP 45/60 Minute
GP 90 Minute
Max. Profile Width:
1-3/4”
2-1/2”
2-1/2”
Max. Profile Height
3/4”
3/4”
3/4”
Wood Specie
Douglas Fir or Denser
Same
Same
Attachment
Adhesive or Mechanical
Adhesive or mechanical
Adhesive
4”
4”
4”
Between Plant-ons
Equal or Greater than Profile
Same
Same
Min. Enclosed Area
N/A
2 Time Profile Width & Height
2 Time Profile Width & Height
Mouldings may not cover in
excess of 20% of door face.
Mouldings may not cover in
excess of 22% of door face.
Mouldings may not cover in
excess of 22% of door face.
Spacing: to edge
of door or cutout
Coverage
25
Notes
Technical Manual
February, 2014
26
Full Glass/Full Warranty Door
8”
Technical Manual
June, 2011
6”
12”
FULL GLASS / FULL WARRANTY DOOR
Maximum Size:
Thickness:
Stiles:
Series:
Faces:
Coutout Size:
Mouldings:
Glazing Material:
Warranty:
4’0” wide x 9’0” high
1-3/4” only
Laminated hardwood construction or veneer banded.
Available as an option only in the GPD EC and GCD EC product lines.
Two ply veneered plywood, 1/8” thick, with face veneer thickness of 1/50” minimum at 12% moisture
content.
Mimimum stile width is 5” from edge of door to cutout.
Minimum rail width is 5” from edge of door to cutout.
These dimensions actual, taken from the prefit size of the door If 20 minute fire rating is required a
maximum 1296 square inches of vision area is allowed.
M2G (lip), M3G (beveled lip), and M6G (flush) profiles are available. All mouldings are sized for installation with 1/4” safety tempered or wired. Moulding or lite kits are not factory attached. For non-fire
rated doors, mouldings must be installed using 3/32” glazing tape on both sides of the glass and must
be fastened every 8” on center using 3rd finish nails (Glazing tape and finish mails are not provided). For
fire rated applications follow the installation intructions for the listed and labeled lite kit specified. With
listed and labeled wood or metal kits may be specified.
For non-fire rated applications 1/4” tempered safety glazing must be used. 1/4” wired glazing may be
specified if desired. (Glazing is not included). For fire rated applications and listed and labeled glazing
materials may be specified.
When finished and installed per manufacturers specifications this product carries a full lifetime warranty against manufacturer defect on interior applications. The product is not warranted for exterior
application in any event. Exterior applications are those which expose a door to extremes of temperature and/or humidity regardless of the physical placement.
27
ElectroLynx™ System
Technical Manual
April, 2011
THE GRAHAM ELECTROLYNX CABLE IS EQUIPPED WITH THE ELECTROLYNX SYSTEM OF PLUG IN
CONNECTORS FOR FAST, EASY, CONNECTION TO SIMILARLY EQUIPPED ASSAABLOY HARDWARE.
THE ELECTROLYNX CABLE HAS 12 CONDUCTORS OF 22 GA. WIFRE, WITH ELECTROLYNX CONNECTORS.
POWER OVER ETHERNET (POE) IS AVAILABLE IF REQUIRED.
CL
5 HINGE DOOR
3/8”
MULTIPLE
CABLE
4 HINGE DOOR
SINGLE
CABLE
SINGLE
CABLE
3 HINGE DOOR
VERIFY CABLE LOCATION
BEFORE MODIFYING DOOR
OR SURFACE APPLICATION OF
HARDWARE.
HINGE EDGE
LOCK EDGE
AVAILABLE IN GPD & GCD DOORS ONLY
ELECTRIC
HINGE
LOCATION
HARDWARE
LOCATION
*ELECTRIC
HINGE
LOCATION
ELECTRIC
HINGE
LOCATION
LOCK EDGE
MULTIPLE
CABLE*
HINGE EDGE
ELECTRIC
HINGE
LOCATION
ELECTRIFIED
TRIM
3/8”
*DOOR MUST BE
PREPPED WITH A
MINIMUM OF
4 HINGES
ELECTRIC
HINGE
LOCATION
FIRE STOP BLOCKING
OR WIDER FIRE STOP
STILE DEPENDING ON
HARDWARE REQUIREMENTS
*THE ELECTROLYNX HINGE WILL ALWAYS
BE LOCATED IN THE SECOND HINGE
FROM THE FLOOR
MAXIMUM OF TWO RACEWAYS PER DOOR ON FIRE-RATED DOORS.
CAN BE USED IN BOTH NEUTRAL & POSITIVE PRESSURE DOORS CATEGORY A & B